GTR 100558785

Request For Quotation Technical Maintenance Services For Main Thermal Wire Networks/Heating Networks And Equipment

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
100558785
Tendering Authority
Subscribe to view
Tender No
15230747
Financer Name
Self-Funded
Work Title
Request For Quotation Technical Maintenance Services For Main Thermal Wire Networks/Heating Networks And Equipment
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
18-08-2025 Closed
Work Detail
Checking The Heat Meter Magik At 2200 By The Electromagnetic Converter Of The Flow Of Du 40 In Full Set With Thermal Transformers To The Address: Kostanay Region, Arkalyk, Awelbekova St., 17., Educational Building No. 1 1. The Heat Meter “Magika Du 40” Pp No. 5531, Pp No. 5538 Zavodskoy No. 601013 (05/25/21 To 05/25/2025) - 1 Set 2. Term Transformers Of The Resistance Of The Ktsp-N Factory No. 10533Xg (2025.05.2021 To 05/25/2025) Note: 1. Verification Of Heat Meters, Resistance Thermal Converters Should Be Carried Out By Qualified Specialists. 2. Conduct A State Verification Of Heat Meters, Resistance Thermal Converters In Organizations That Have Metrological Accreditation. 3. After Checking The Devices, Provide Certificates Description And Required Functional, Technical, Quality And Operational Characteristics Contractors Responsibilities: 1. Dismantling Of Heat Meters 2. Preparation Of Instrumentation For Verification: Cleaning The External Surfaces Of Heat Meters From Dust And Other Pollution, Washing The Running Part From Rust And Scale, Removal Of Gaskets; 3. Checking The Timer Lithium Battery, If Necessary, Replace; 4. Verification Of Components Of Heat Meters With The Issuance Of A Certificate Of Verification For Each Component Separately; 5. Installation Of Heat Meters After Checking; 6. Setting Up The Heat Meters In The Kit At The Installation Site; 7. Commissioning To The Inspector Of The Heat Supply Organization; 8. The Contractor Independently Submit An Application To The Supplier Of Services To Remove The Seals From The Heat Meter (Before Checking), To Seal The Heat Meter (After Verification) A Prerequisite: When Connecting The Object To The City Heat Supply System (When Heating), The Presence Of The Contractor To Verify The Correctness Parameters., Checking The Heat Meter Magik At 2200 By The Electromagnetic Converter Of The Flow Of Du 40 In Full Set With Thermal Transformers At The Address: Kostanay Region, Arkalyk, Zhanibeku St., Gym, Training Building No. 2 1. The Heat Meter Magika Du 40 Pp No. 5749, Pp No. 5753 Zavodskoy No. Ea 601012 (05.24.21 To 05.24.2025 G) - 1 Set 2. Term Transformers Of The Resistance Of The Ktptr Zavodskoy No. 5312X, No. 4614G (2024 To 2028) Note: 1. Verification Of Heat Meters, Resistance Thermal Converters Should Be Carried Out By Qualified Specialists. 2. Conduct A State Verification Of Heat Meters, Resistance Thermal Converters In Organizations That Have Metrological Accreditation. 3. After Checking The Devices, Provide Certificates Description And Required Functional, Technical, Quality And Operational Characteristics Contractors Responsibilities: 1. Dismantling Of Heat Meters 2. Preparation Of Instrumentation For Verification: Cleaning The External Surfaces Of Heat Meters From Dust And Other Pollution, Washing The Running Part From Rust And Scale, Removal Of Gaskets; 3. Checking The Timer Lithium Battery, If Necessary, Replace; 4. Verification Of Components Of Heat Meters With The Issuance Of A Certificate Of Verification For Each Component Separately; 5. Installation Of Heat Meters After Checking; 6. Setting Up The Heat Meters In The Kit At The Installation Site; 7. Commissioning To The Inspector Of The Heat Supply Organization; 8. The Contractor Independently Submit An Application To The Supplier Of Services To Remove The Seals From The Heat Meter (Before Checking), To Seal The Heat Meter (After Verification) A Prerequisite: When Connecting The Object To The City Heat Supply System (When Heating), The Presence Of The Contractor To Verify The Correctness Parameters., Checking The Heater Magica At 2200 By The Electromagnetic Converter Of The Flow Rate Of Du 40 In Full Set With Thermal Transformers At The Address: Kostanay Region, Arkalyk, Kaiyrbekova St., Dormitory House Of Students No. 1. 1. Magika Du 40 Pp No. 5545, Pp No. 5561 Zavodskoy No. 601019 (05/25/21 To 05/25/2025 G)-1 Set 2. Term Transformers Of The Resistance Of Ktsp-N Factory No. 10528X/G (05/25/21 To 05/25/2025 G) Note: Note: 1. Verification Of Heat Meters, Resistance Thermal Converters Should Be Carried Out By Qualified Specialists. 2. Conduct A State Verification Of Heat Meters, Resistance Thermal Converters In Organizations That Have Metrological Accreditation. 3. After Checking The Devices, Provide Certificates Description And Required Functional, Technical, Quality And Operational Characteristics Contractors Responsibilities: 1. Dismantling Of Heat Meters 2. Preparation Of Instrumentation For Verification: Cleaning The External Surfaces Of Heat Meters From Dust And Other Pollution, Washing The Running Part From Rust And Scale, Removal Of Gaskets; 3. Checking The Timer Lithium Battery, If Necessary, Replace; 4. Verification Of Components Of Heat Meters With The Issuance Of A Certificate Of Verification For Each Component Separately; 5. Installation Of Heat Meters After Checking; 6. Setting Up The Heat Meters In The Kit At The Installation Site; 7. Commissioning To The Inspector Of The Heat Supply Organization; 8. The Contractor Independently Submit An Application To The Supplier Of Services To Remove The Seals From The Heat Meter (Before Checking), To Seal The Heat Meter (After Verification) A Prerequisite: When Connecting The Object To The City Heat Supply System (When Heating), The Presence Of The Contractor To Verify The Correctness Parameters.
Key Value
Tender Value
540,000 - KZT
Tender Documents
Global Tender Document
7c59c8d9-6195-4156-9dd6-d9e1e03386bd.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders