Tenders Are Invited For Thermomodernization Of The Building Of The Volunteer Fire Brigade In Grabów

Tender Detail

100472635
ZP.1.2025
Self-Funded
Tenders Are Invited For Thermomodernization Of The Building Of The Volunteer Fire Brigade In Grabów
NCB
central europe
European Union
20-08-2025

Work Detail

1. The Subject Of The Contract Is The Thermomodernization Of The Building Of The Volunteer Fire Brigade In Grabów, Including: 1) Replacement Of The Heat Source (Boiler For Heating Oil) With A Heat Pump Air With 16 Kw Water (The Ordering Party Requires The Pump To Be On The Zum List) Along With The Necessary Elements Of The Installation. The Position Also Contains The Adaptation Of The Boiler Room Room To The New Heat Source Along With The Utilization Of The Old Installation. 2) Installation Of A 9.6 Kw Solar Installation With A Power Warehouse With 0.01Mwh, 3) Replacement Of Two Garage Gates And Entrance Door To The Building (Garage Door With An Automatic Opening System And Closing From Materials With High Resistance To Mechanical Damage And Atmospheric Conditions, 1 Gate Built -In Entrance Door, Maximum Permissible Value Of The U = 1.3W/M2xk Coefficient), 4) Replacement Of The Existing Window Joinery With Pvc Windows With A Factor U = 0.90W/M2xk - 1.1W/5) Insulation Of The Cemethants With Mineral Wool Gr. 20Cm With A Lambda Factor Not More Than 0.033 W/M2. The Set List And Description Of The Window And Door Joinery Constitutes Annex 6 To Swz Existing State: The Building Of The Tso Fire Station In Grabowiebudyne, One-Story One-Story One-Storey With A Utility Attic Made In Traditional Brick Technology, Wooden Roof In The Rafter-Eaidal Structure. Building Area 171.39M2, Usable Area 264.85M2. On The Ground Floor Of The Building There Are 2 Garage Boxes, A Boiler Room And A Utility Room, A Commanders Room And Sanitary Facilities On The Member, A Common Room On The Attic, Kitchen Facilities, Utility Rooms, Communication And Sanitary Facilities. Garage Gaters Case With Dimensions 350X350- 2 Pcs. Entry Doors For A Building With Dimensions Of 110X210, Door To The Boiler Room 100X200. Window Joinery With Dimensions Of 151X151- Pcs. 6.91X151 Pcs. 2, Roof Window 90X120- 1 Pcs, Balcony Doors 131X230- 1 Pcs. Detailed Description The Subject Of The Order Was Specified In The Energy Review Of The Project Constituting Annex 4, Energy Audit Ex-Ante- Constituting An Attachment No. 7 To Swz. As An Auxiliary Element, The Employer Attachments From The Construction Project Attached As Annex 5 To Swz. 2. Requirements For The Technical Parameters Of Individual Systems (Applies To Both Parts): 1) Air/Water Pump With An Elevated Energy Efficiency Class (For 55Oc Supply Temperature), Split, Energy Efficiency Class Min. A ++, Type Of Working Factor R32 (The Contracting Authority Also Allows The Type Of Working Factor R290), Equipment With Weather Regulation Enabling The Control Of The Heating Curve. System With Built -In Water Buffer With A Capacity Of Min. 200 L. The Contracting Authority Requires That The Pump Be On The Uti List. 2) Photovoltaic Installation - A Single Panel Power From 425 W To 460 W, Double Protective Glass, Mechanical Resistance To Snow Load Min. 5000 Pa And Wind Min. 3500 Pa, Operating Temperature Range From -40Oc To +85Oc. The Solar Installation Will

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail