GTR 100341951
Bids Are Invited For Acquisition Of Permanent Equipment And Materials (Medical And Other Devices), For A Specialized Health Care Unit, Through Proposal No. 11185.701000/1220-11, Using Parliamentary Amendment To Meet The Needs Of The Municipal Health Secretariat Of Palmeira Dos Índios/Al, According To Conditions, Quantities And Requirements Established In The Notice And Its Attachments.
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
100341951
Tendering Authority
Subscribe to view
Tender No
023/2025/2024
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisition Of Permanent Equipment And Materials (Medical And Other Devices), For A Specialized Health Care Unit, Through Proposal No. 11185.701000/1220-11, Using Parliamentary Amendment To Meet The Needs Of The Municipal Health Secretariat Of Palmeira Dos Índios/Al, According To Conditions, Quantities And Requirements Established In The Notice And Its Attachments.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
22-08-2025
Closed
Work Detail
Ions/Electrolyte Analyzer - With Minimum Of 04 Parameters: Na+, K+; Cl-; Ca+2, With Total Blood Reading, Serum, Plasma Or Urine And With A Sample Volume Of 150 Ul Or Smaller; Must Perform At Least 60 Analyzes Per Hour; With Automatic Calibration, Numerical Alpha Display, Thermal Printer And Rs232c Serial Port; 220V Power Supply. Have Registration With Anvisa/Ms., X -Ray Apparatus - Digital Fixed; High Frequency Micro Processed Generator; Power Of At Least 50 Kw; Variable Voltage That Minimally Meets The 40 Kv Range To 125 Kv Or Larger; Variable Current In The Minimum Range Of 50Ma To 500M Or Larger; Minimum Exposure Time Of 5Ms Or Lower, 4S Or Larger, Razor Bone Densitometry Apparatus - X - With At Least 16 Detectors And Technology For The Purchase Of Images In Single Passage Without Overlap Or Subsidiary Of Data, Fan Beam Or Higher. Linear X-Ray Beam Technology Using Motorized Table And C-Arm With Opening Of At Least 16 Inches; Scan Image Acquisition Time Located 30 Seconds, Split Type Air Conditioning-Capacity 9,000 Btus; Cycle: Hot And Cold. The Device Must Have The Inmetro Conformity Identification Seal, According To Ordinance No. 269, Of 2021 And Changes., Horizontal Table Autoclave (Up To 75 Liters) - Digital Operation Mode; Capacity: Up To 25 Liters., Adult Anthropometric Balance - Mechanical Operation Mode; Capacity: Up To 150 Kg; Anthropometric Ruler Up To 2 Meters., Childrens Anthropometric Balance - Digital Type; Capacity Up To 16 Kg; Shell Dimension: Minimum 540 X 290 (Mm); With Tara., Ultrasonic/Ecobobiometer Biometer - Minimum Characteristics: Ultrasonic Contact And Immersion, Available Probe: 10 Mhz (Ultrasonic Biometrics); Formulas For Calculating Lio: Holladay, Regression Ii (Srk Ii), Theoretic-T (Srk-T), Haigis., Ophthalmological Chair-Reclining Backrest; Type Of Drive: Automatic; With Movement., Otorhinological Chair - Reclining Backrest; Automatic Drive; Giatory Movement., Coagulometer - Of At Least One Channel. Determination Of At Least: Tp, Ttpa, Thrombin, Fibrogen And Coagulation Factors. You Must Provide Tp Results In At Least Activity (%), Inr And Ratio. The Software Should Allow Storage Of At Least The Last 100 Results And Tp And Fibrinogen Curves. Must Have Embedded Printer On The Equipment. Voltage According To The Requesting Entity., Ophthalmological Column - With Pantographic Arm. Focus Of Articulated Light, With Intensity Control. Power Supply For Ophthalmoscope, Retinoscope., Manual Cell Counter - Digital Type; 14 Keys., Cr - Radiographic Image Scanner (Monocasete) - X -Ray Image Scanning System By Monocassete Phosphorus Plates. Conventional Radiology Image Digitizations Must Have A Minimum Resolution Of 10 Pixels / Mm In All X-Ray Cassette Sizes. Minimum Processing Capacity Of 40 Cassettes / Hour In Size 35 X 43 Cm. Operation Console Dedicated To The Review Of X-Ray Digital Images. Digitization Of Mammography Images With Minimum Resolution Of 20 Pixels / Mm In Cassette Sizes 18 X 24 Cm And 24 X 30 Cm. Minimum Processing Capacity
Key Value
Tender Value
2,884,681 - BRL
Tender Documents
Global Tender Document
7d3b72da-3bef-44f2-8443-770cfd23b98b.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.