BRR : 9900265
Click Here To View Tendering Authority. Price Bid City/State :  badaun, Uttar Pradesh
Tender Brief : Tender For Tourism Development Work Of The Mythological Pilgrimage Site Sahasbahu In Sahaswan Of Badaun District.-PROPOSED DEVELOPMENT & BEAUTIFICATION WORK OF PAURADIK TEERTH STHAL, SARSAUTA , SAHASWAN, DISTT – BADAUN (U.P.)-PROPOSED WORK 2.6.1 Excavation in foundation in ordinary soil (loam clay sand) including lift up to 1.5 m and lead up to 30m. And including filling watering and ramming of excavated earth into the space between the building and the sides removal and disposal of surplus earth as directed by the engineer in charge up to a distance of 30m from the doundation trenches includ... Read More
Tender Value
Ref. Document
Submission Date
16-02-2026
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 55,91,936.76 L1
2 cnet-technologies Bid Analytics 56,93,712.3 L3
3 cnet-technologies Bid Analytics 56,89,138.12 L2
Work Detail
tender for tourism development work of the mythological pilgrimage site sahasbahu in sahaswan of badaun district.-proposed development & beautification work of pauradik teerth sthal, sarsauta , sahaswan, distt – badaun (u.p.)-proposed work 2.6.1 excavation in foundation in ordinary soil (loam clay sand) including lift up to 1.5 m and lead up to 30m. and including filling watering and ramming of excavated earth into the space between the building and the sides removal and disposal of surplus earth as directed by the engineer in charge up to a distance of 30m from the doundation trenches including all t&p phowarah and basket etc. complete. 2.25 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2.27 supplying, and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 4.1.8 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5.33.1.1 providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportions as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-incharge; for the following grades of concrete. 5.33.2.1 all works above plinth level upto floor v level concrete of m25 grade with minimum cement content of 330kg/cum for columns 5.9.1 foundations, footings, bases of columns, etc. for mass concrete 5.9.6 columns, pillars, piers, abutments, posts and struts 5.9.21 lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 5.9.3 suspended floors, roofs, landings, balconies and access platform 5.22.6 reinforcement for rcc work including straightening, cutting, bending, placing in position complete. - thermo-mechanically treated bars. proposed work 2.35.3 diluting and injecting chemical emulsion for preconstructional anti-termite treatment (excluding the cost of chemical emulsion) treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 coarse sand) to match the existing floor: with chlorpyriphos/lindane e.c. 20% with 1% concentration 4.1 providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) 6.1.2 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: cement mortar 1:6 (1 cement : 6 coarse sand) 6.4.2 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand) 13.4.2 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) 5.3 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 9.1 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). sal wood 9.5.1.1 providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of engineer-incharge. (note: butt hinges and necessary screws shall be paid separately) second class teak wood 35 mm thick shutters. 9.147.a1.2 providing and fixing factory made upvc glazed/wire mesh windows/ doors comprising of lead free upvc multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for series r1 and r2 profiles and 2.10 mm for series r3 and r4 profiles conforming to en: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per cpwd specification, upvc extruded glazing beads, interlocks and inline sash adaptor (where ever required) of appropriate dimension, epdm gasket, hardware, ss 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide pa6 grade sleeve for fixing frame to finished wall as per is 1367 : part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. 9.55.1 providing and fixing isi marked m.s. pressed butt hinges bright finished with necessary screws etc. complete :125x65x2.12 mm 9.75.1 providing and fixing 300x16x5 mm bright finished brass door latch with necessary screws etc. complete 9.63.2 providing and fixing isi marked oxidised m.s. tower bolt black finish, (barrel type) with necessary screws etc. complete 200x10 mm 9.66.2 providing and fixing isi marked oxidised m.s. handles conforming to is:4992 with necessary screws etc. complete 100 mm 9.82 providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. 11.41. providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm 11.26.1 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 11.29 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 13.8 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.48a.1 finishing exterior walls with 100% premium acrylic emulsion paint having voc less than 50 gm/litre and uv resistance as per is 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives. new work (two or more coats applied @ 1.43 litre/ 10 sqm. over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 13.41.1 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre dsr 13.68.1 french spirit polishing : two or more coats on new works including a coat of wood filler dsr 22.7.1 providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer-in-charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. proposed work 12.41.2 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes 110 mm diameter 12.42.1.2 providing and fixing on wall face unplasticised - pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion.coupler 110 mm 12.42.6.2 shoe (plain) 110 mm 12.43.2 providing and fixing unplasticised -pvc pipe clips of approved design to unplasticised - pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 12.22 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete 1.10.3 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1.12 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1.14 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 1.14.1 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire 1.14.4 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 1.14.9 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire proposed work 40192 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 40557 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 1.21 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 1.21.1 20 mm. 1.21.2 25 mm. 1.31 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required 1.32 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 1.25 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1.26 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 1.27.1 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess etc as required- 1 or 2 module (75 mm x 75 mm) 2.4 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2.4.1 4 way (4 + 12), double door, horizontal type 2.10.1 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required- single pole supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required 2.13.1 40 amps. 2.13.2 63 amps. 2.11 supplying & fixing single pole, blanking plate in the existing mcb db complete etc. as required. proposed work 1.45 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. m.r. supply and fixing of led tube light with batten suitable for up to 1 x 22 watt led tube light fitting including tube on surface complete in all respect. cat- aaa m.r. supply and fixing of 12 watt to 15 watt indoor recess mounting led square fitting for armstrong ceiling having powder coated die cast aluminium housing with extended heat sink, diffuser of polycarbonate meterial and driver set complete in all respect. cataaa m.r. supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cmm/w) minimum 6.85, air delivery minimum 215 cmm, 350 rpm (tolerance as per is : 374- 2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required.1200 mm sweep m.r. supply of ac 230/250 volts, 50 hz exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete 300 mm sweep 900 rpm m.r. supply, installation, testing and commissioning of main distribution board suitable for upto 125 amp fp mccb incomer and single / three phase outgoing mcbs, ip 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 v / 200 amp copper bus bar, earth and neutral bar, removable gland plates, cable glands including connection with outgoing feeders complete in all respect. dbs shall be original factory fabricated of approved make. the rates shall be excluding all incoming and outgoing circuit breakers.8 way tpn m.r. supply & fixing of 30w solar street light - 7 meter pole , foundation bolt ,bracket ( luminary / panel),125 w solar panel, 12.8v / 78ah lipo4 .battery top- 70mm , bottom - 130mm , etc all complete of direction of engineer in charge. m.r. drinking water cooler proposed work m.r. dustbin m.r. bench
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 5ff42ee2-a662-4b7e-824e-523faa27e3c3 technicalevaluation notice
Download technical_2065129 aoc document
Download techsummary_2065129 aoc document
Download 794b7f83-904b-445a-8584-715791e32b7c financialevaluation notice
Download boqcomparativechart document
Download finance_2065129 document
Download File Name File Description
Download tenderdocuments Tender Documents
Download Tendernotice_1 Tender Documents
Download 6c9ced90-dcf7-4240-89c5-79db2d4092bf Tender Documents
Download boqpdf Tender Documents
Download BOQ_2065129 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders