BRR : 9372306
Tender Brief : Water Supply for Ganpati Devsthan Maturlingat Siddhapur Tal. Mangalwedha - Bore Well - Survay Bore well Point 2 Bore Well drilling work of 200/215mm Dia.in soil/murum strata and drilling of 150 mm dia.in hard rock (wet drilling) 3 Proding & Fixing 160 MM Dia. 6KG PVC Pipe For Casing 4 For 150 mm bore well Yeild Testing of bore well by flushing after completion of bore well 5 Proding & Fixing PVC 180 mm dia. Bore Cap 6 Pumping Mashinary - Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall ... Read More
Tender Value
₹
24,82,517
Submission Date
03-10-2025
Participated Bidder List
10 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics | |||||
| 5 | cnet-technologies | Bid Analytics | |||||
| 6 | cnet-technologies | Bid Analytics | |||||
| 7 | cnet-technologies | Bid Analytics | |||||
| 8 | cnet-technologies | Bid Analytics | |||||
| 9 | cnet-technologies | Bid Analytics | |||||
| 10 | cnet-technologies | Bid Analytics |
Work Detail
water supply for ganpati devsthan maturlingat siddhapur tal. mangalwedha - bore well - survay bore well point 2 bore well drilling work of 200/215mm dia.in soil/murum strata and drilling of 150 mm dia.in hard rock (wet drilling) 3 proding & fixing 160 mm dia. 6kg pvc pipe for casing 4 for 150 mm bore well yeild testing of bore well by flushing after completion of bore well 5 proding & fixing pvc 180 mm dia. bore cap 6 pumping mashinary - providing, erecting and giving test of submersible pump set conforming to is 8034 and motor conforming to is 9283, with water proof winding. pump shall be suitable for various delivery head and discharge with stainless steel shaft. motor suitable for working on 415 v ± 10%, 3 ph, 50 hz a.c. supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust the pump set shall be suitable for direct coupling, with suitable suction strainer. pump should have suitable discharge out let as per manufacturers design. antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump submersible pump 150 mm dia (with bronze / stainless steel (cf8m) impeller) up to 8 stages1 6/pm 1-2-550 hp 7 providing and supplying in standard lengths polyethelene pipes, confirming to is 4984 /14151/ 12786/13488 with nesessary jointing material like mechanical connector i. e.thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading/ unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding gst levied by gi & gom in all respect etc. complete. 146/1a ii) 75 m,m 8 lowering, laying and jointing h. d. p. e./m. d.p. e. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent is code complete with all materials for jointing procedure like electrofusion machine, electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc and all labours as directed by engineer in charge as per is-7634 part ii ii) 75 m.m 9 supplying & erecting flat flexible 3 core 6 sq.mm pvc sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete 220/12-4-10 10 supplying & erecting automatic control panel for 3 phase, 415 volt, a.c, submersible/centrifugal pump set up to 7.5 hp consisting of dol starter having relay range 9-14 amp,s.p.p., combined ammeter/ voltmeter, phase indicating lamp enclosed in crca powder coated vibration proof enclosure with ip 54 protection. control panel should offer single phasing, phase reversal, phase imbalance etc 220/12-4-17 11 supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270v and output voltage 200-250v rated for 3kva maximum load and with voltmeter, selector switch, 6a/16a flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16a plug top with overload & short circuit protection complete 58/3-9-3 12 supplying and erecting panel mounting type digital ammeter having three and half digit led display, external ct operated, calibrated for suitable to operate on 500v, 0 to 1000a having accuracy class of 05, ac supply with necessary pvc wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer 120/6-3-7 13 supplying and erecting bank of all polypropylene 710 capacitors with the standard capacities of 75,84,116,133 and 167 kvar units of power factor correction for operation on 3 phase, 50 hz. 3300 v+/- 6% with externally discharging resistances, earthing terminals and built on angle iron on channel iron frame work and provided with terminal cover box, h.t. bushing bus bar and hrc fuses etc complete erected and tested 41/cp3 14 panel fabrication gi sheet of thickness given below to be used for fabrication of boxes. panel board etc. including cutting, bending, drilling, welding, cleaning. degusting and painting with one coats of red lead paint and two coats of enamel paint 15 providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. ea-ep elec csr 2017-18 176/9-1-2 16 supplying and erecting, triple pole iron clad /metal clad switch with rewire able fuse 415/500 volts of suitable rating with neutral link of below rating of approved make. 16 ampere 17 supplying and erecting set of three pilot lamp indicating camp with lead colors red/yellow/blue 230/250 volt on provided box/panel with necessary wiring material connection etc. [elect/mech dsr 2013-14 page no.81 code no.6-5-6] 18 rising main - excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (bd-a-1/259) 52/1 19 excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 m and lifts as below, stacking and spreading as directed by engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc complete (bd-a-2/259) 52/2 20 excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 m beyond the area and lifts as below, stacking as directed by engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc complete (bd-a-4/259) 52/5 21 filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc complete (bd-a-10/263) 56/17 22 providing and supplying in standard lengths polyethelene pipes, confirming to is 4984/14151/12786/13488 with nesessary jointing material like mechanical connector i. e. thread/insert joint/quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading/unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding gst levied by gi & gom in all respect etc complete. 146/1 iii) 90 mm 23 lowering, laying and jointing hdpe/mdpe pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent is code complete with all materials for jointing procedure like electrofusion machine, electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all tabours as directed by engineer in charge as per is-7634 part 11 147/2 vii) 90 mm 24 hydraulic testing of pvc pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. the rate under this item shall also include cost of retesting, if necessary and reinstating to original position. (mjp dsr 2019-20, pg. no.100 /106 ) 90 mm diameter of 4 kg/cm2 25 refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 55/16 26 valve chamber with precast rcc covers providing and constructing b.b. masonry valve chamber with 15 cm thick 1:3:6 proportion pcc bedding, excluding excavation, b.b masonry in cm 1:5 proportion precast rcc frame and cover, etc. complete as directed by engineer-in-charge 320/1as above of 60 x 45 cm internal size and depth upto 0.9 m with precast rcc slab cover 255/1 a 27 providing and supplying air valves as per is-14845-2000 and mjps standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding gst levied by goi & gom in all respect etc. complete. 175/5 aii) 20 mm. 28 lowering, laying and fixing in proper alignment and position all types of c.i. air valves as directed by engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete. (for all class of valves). 178/10 aii) 20 mm. 29 providing and fixing in position air valve shaft including providing and fixing gi medium class or 6 mm thick m.s. pipe shaft 2.70 m long over branch flange of air valve tee, providing pcc block of m-150 concrete, 150 mm thick around the air valve tee including encasing of vertical shaft in pcc m-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve tee, etc.complete as per type design and as directed by engineer -in- charge for followingdiameters of pipe lines (type design attached.) a) foundation on murum and harder strata i)upto 150mmmjp dsr 2021-22 181/17 foundation in b. c. soil orany other so150 30 providing and laying situ cement concrete m-15 of trap /granite/quartzite/ gneiss/metal for foundation & bedding including bailing out water, frame workcompacting, curing etc.complete.. 60/1b) in pcc m150 31 distribtion system - excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (bd-a-1/259) 52/1 32 excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 m and lifts as below, stacking and spreading as directed by engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete (bd-a-2/259) 52/2 33 excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 m beyond the area and lifts as below, stacking as directed by engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (bd-a-4/259) 52/5 34 filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete (bd-a- 10/263) 56/17 35 providing and supplying in standard lengths isi mark rigid unplasticised pvc pipes suitable for potable water with solvent cement joints including cost of couplers, as per is specification no. 4985/1988 excluding gst levied by goi and gom in all respect, including transportation, freight charges, inspection charges, loading. unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i e solvent cement, etc. complete (selffit type to be jointed with cement solvent) 140 mm/4kg 36 90 mm/4kg 37 lowering, laying and jointing with p.v.c pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring as per is code, etc complete (with cement solvent joint/ring fit joint). note: for pvc o pipes of all pressure 4 (b) rates applied 140 mm/4kg 38 90 mm/4kg 39 hydraulic testing of pvc pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. the rate under this item shall also include cost of retesting, if necessary and reinstating to original position. (mjp dsr 2019-20, pg. no.100 /106 )140 mm diameter of 4 kg/cm2 40 90 mm diameter of 4 kg/cm2 41 refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 55/16 42 providing double flange sluice valve confirming for is-14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding gst lev80 mm 43 100 mm. 44 125 mm. 45 lowering, laying and jointing in position following c.i.d/f reflex valves, butterfly valves and sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete. (rate for all class80 mm. 46 100 mm. 47 125 mm. 48 providing and fixing c.i road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc complete 322/5 49 providing and laying situ cement concrete m-15 of trap /granite/quartzite/ gneiss/metal for foundation & bedding including bailing out water, frame workcompacting, curing etc.complete.. 50 stand post excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (bd-a-1/259) 48/1 51 providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (bd-a-12/264) 52/18 52 providing and laying in situ cement concrete m-15 of trap/ granite /quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (cement 5.90 bags/cum) 60/b) in pcc m-150 53 providing and laying in situ cement concrete of trap/ granite /quartzite / gneiss metal for rcc work in foundation like raft, grillage, strip foundation and footing of rcc columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (by weigh batching and mix design for m250 and m-300 only. use of l&t, a.c.c., ambuja, birla gold, manikgad, rajashree, etc. cement is permitted.) (excluding m.s. or tor reinforcement) 60/2b) in rcc m-200 54 providing and casting in situ cement concrete of trap/ granite quartzite / gneiss metal of approved quality for rcc works as per detailed drawings and designs or as directed by engineerin charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with cm 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (by weigh batching and mix design for m-250 and m-300 only. use of l&t, a.c.c., ambuja, birla gold, manikgad, rajashree, etc. cement is permitted.) (excluding m.s. or tor reinforcement) 60/3 b) in rcc m-200 55 providing and fixing in position steel bar reinforcement of various diameters for rcc piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete 56 providing first class burnt brick masonry with conventional/ i.s. type bricks in cement mortar 1:6 in plinth including bailing out water manually, striking joints on unexposed faces, pointing with cement mortar 1:3 on exposed face and watering etc. complete. 204/890 57 providing internal cement plaster 20mm. thick in single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. 216/962 58 providing and fixing heavy duty inter locking concrete grey paving blocks of 80 mm thickness of having a strength of 300 kilogram/sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. 59 providing isi mark g.i. pipe of following class and dia.excluding gst levied by goi & gom in all respect, inspection charges, transportation to stores, etc. complete as per is-1239/2004. note: one coupler shall be provided with each full length of pipe cost of which is included in rates below. 110/1 b) medium ix) 100 mm. (12.40 kg./m) 60 lowering, laying and jointing g. 1. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by engineer-in- charge 110/1 b) medium x) 100 mm. (12.40 kg/m) 61 providing and fixing 15 mm dia screw down bib/stop tap of brass including necessary socket union nut complete. 279/ 62 providing isi standard r.c.c. pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints. excluding gst lev-ied by goi & gom in all respect including inspection charges, transport to departmental stores, unloading and stacking etc. complete as per is-458/1988 63 lowering, laying and jointing in proper grade and alignment r.c.c. pipes with collar joints in c.m. 1:1 proportion or socketed r.c.c. pipes with rubber joints (excluding cost of rubber ring or r.c.c. collar,) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc. complete as directed by engineerin-charge (for all class of pipes) as per is-783-1985.. 64 mseb quotation 65 add gst 18%
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results