BRR : 8566674
Click Here To View Tendering Authority. Aoc City/State :  Pune, Maharashtra
Tender Brief : Tender For Provision Of Otm Accommodation For Centre Under Ge (C) Khadki; 1 SCH A PART-I: BUILDING AND STRUCTURESNote: This schedule ispre-priced by MES and the rate indicated as under Col 5 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Structures) 3 Total amount of Sch A Part-II(Site Clearance,Excavation and Earthwork) 4 Total amount of Sch ‘A’ Part III (Internal Water supply) 5 Total amount of Sch ‘A’ Part IV (Internal Electric Supply) 6 Total amount of Sch ‘A’ Part V (Road, Path and Culverts) 7 Total amount of Sch ‘A’ Part VI (Area Drainage) 8 Total amount o... Read More
Tender Value
7,50,00,000
Contract Value
₹ 6,11,96,377.06
Saving / Difference
₹ 1,38,03,623 ▲
Submission Date
28-11-2025
Contract Date
08-01-2026
Completion Date
365 days
Participated Bidder List
8 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 7,84,41,500 L6
2 cnet-technologies Bid Analytics 6,11,96,377.06 L1
3 cnet-technologies Bid Analytics 6,39,00,000 L2
4 cnet-technologies Bid Analytics 7,09,87,380 L3
5 cnet-technologies Bid Analytics 7,35,65,545 L5
6 cnet-technologies Bid Analytics
7 cnet-technologies Bid Analytics 10,63,82,700 L7
8 cnet-technologies Bid Analytics 7,14,46,559.05 L4
Work Detail
tender for provision of otm accommodation for centre under ge (c) khadki; 1 sch a part-i: building and structuresnote: this schedule ispre-priced by mes and the rate indicated as under col 5 signifies this fact only 2 total amount of sch ‘a’ part i (building & structures) 3 total amount of sch a part-ii(site clearance,excavation and earthwork) 4 total amount of sch ‘a’ part iii (internal water supply) 5 total amount of sch ‘a’ part iv (internal electric supply) 6 total amount of sch ‘a’ part v (road, path and culverts) 7 total amount of sch ‘a’ part vi (area drainage) 8 total amount of sch ‘a’ part vii (sewage disposal) 9 total amount of sch ‘a’ part viii (external water supply) 10 total amount of sch a part-ix (external electric supply) 11 total amount of sch a part-x (rain water harvesting) 12 total amount of sch a part-xi (lightening protection) 13 total amount of sch a part-xii (wiring for equipment load ) 14 total amount of sch a part-xiii (retaining wall) 15 schedule a part-xiv (misc b/r ande/m works)note: this schedule is not pre-priced by mes and the rate indicated as rs 0.00 under col 6 signifies this fact only. 16 m&l excavation over areas in any kind of soilnot exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) complete and all as specified and directed. 17 all as per item no. 15.10 but for depth exceeding 1.5 m but not exceeding 3.0 m by manual means or mechanical means (hydraulic excavator) including lift upto depth of 3.0 m in any kind of soil complete and all as specified and directed. 18 m&l excavation in trenches in any kind of soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 sq.m on plan, including dressing of sides and ramming of bottoms, inlcuding lift upto 1.5 m and getting out the excavated soil, complete all as specified and directed. 19 m&l excavation in trenches in any kind of ordinary rock not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 sq.m on plan, including dressing of sides and ramming of bottoms, inlcuding lift upto 1.5 m and getting out the excavated rock, complete all as specified and directed. 20 all as per item no. 15.40 but for depth exceeding 1.5 m but not exceeding 3.0 m by manual means or mechanical means (hydraulic excavator) including lift upto depth of 3.0 m and getting out the excavated rock, complete all as specified and directed. 21 m&l excavation in trenches in any kind of hard rock (without blasting) not exceeding 1.5 m wide and not exceeding 1.5 m in depth by manual means or mechanical means (hydraulic excavator) in foundation trenches or for shafts, walls, cesspits, manholes, pier holes, laying pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 sq.m on plan, including dressing of sides and ramming of bottoms, inlcuding lift upto 1.5 m and getting out the excavated hard rock, complete all as specified and directed. 22 s&f led bulb 9 w complete all as specified and directed. 23 s&f street light bracket made out of 25 mm dia gi tubing, medium grade isi marked including ms clamp duly painted with two coats of synthetic paint over a coat of red oxide primer, tightening nuts, bolts, washers and taking out existing unserviceable rusted gi bracket complete all as specified and directed. 24 s&f vertical distribution board iron clad double door with ip-43, 1k-09 protection suitable for mccb incomer and mcb spn as outgoing 415volts 3 phase 50 c/s 4 way, complete with appropriate size copper bus bar and neutral link confirming to cat pt no. 607790 of legrand or equivalent of make hager / merlin gerin multi-9 complete including cutting chases to wall for fixing db and making good the disturbed wall surface complete all as specified and directed. 25 s&f spn afdd, 40a offering protections for overload, short circuit, residual current characteristics type a, over voltage protection above 270 ac plus minus 5% & series parallel arc fault. afdd must be dual test button for afdd and earth leakage functions along with single diagnostic led with blinking patterns for continuous on, series arc, parallel arc and overvoltage protection complete all as specified and directed. 26 m&l cable route indicator duly embossed 11kv for ht ug cable of 11000 volts 80 mm dia ci plate marked on ht cable bolted with 40 x 5mm flat iron of hight 0.4mtr embedded in pcc 1:3:6 type c2 of size 20 x 20 x 30 cm block complete all as specified and directed. 27 supply & install, testing and commissioning step down transformer, out door type and conforming to is 1180:2014, level -2 plinth mounted, ht 11 kv, 3 phase 433 volts, 4 wire, 50 hz delta/star connected, vector group dyn -11 double copper wound, onan, manual type off load tap changing facility on ht side to vary secondary voltage from minimum 7.5% to plus7.5% in steps of 2.5 % continuous rating of capacity 250 kva including bushing on ht end cable box on lt side the transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil is 335 isi marked filtered & dehydrated oil etc, complete all as specified and directed and compression of the following accessories :- (a) primary hv side suitable for oh conductor (consisting of 3 nos porcelain ht bushings with brass/gun metal bushing rods complete with nuts and washer.(b) one cable box on secondary (lv) side consisting of 4nos porcelain busing with gm bushing roads complete with gh nuts and washer with one nos cable bland suitable for reception of out going lt armoured cables of suitable size.(c) oil conservator tank with filter type, drain valve and oil level gauge.(d) dehydrating breather with first fill of dehydrating agent. (e) thermometer pocket on tank cover (f) one nos100mm dia dial type thermometer vapour pressure type having range 0-120 degree centrigrade with temp reading pointer. 28 supply and install automatic power factor correction (apfc) panel out door type factory made of capacity 100 kvar ready to use design confirming to relevant is rated for short circuit rating of 100 ka front openable and lockable by keys having louver and air vent, gasket and totally verming proof and suitable for 415/440 volts, 3 phase 50 hz ac and housed in elegant enclosure fabricated from minimum 3.15mm thick crca sheet, anti corrosive coated to achieve power factor from 0.9 t0 0.99 and finally powder coated in texture siemens gray ral 7032 & as a directed by engineer -in- charge comprising of and including following suitable size and length of copper cable from main panel to apfc panel for connections as approved complete all as specified and directed :-(a) 100 a capacity for phase and 63 a neutral aluminium bush bar duly insulated with colour coated heat shrinkable sleeves and mounted on suitable dmc/epoxy insulator.(b) mccb 160 amp 25 ka tp tm based o/c and s/c rel -01 nos incoming(c) 6a fpmcb 10 ka -03 nos (d ) 10 amp tp mcb 10 ka -02 nos (e) 20 a tp mcb 10 ka -01 nos (f) 25 amp tp mcb 10 ka -03 nos (g) power contactor 9.7 kvar tp cap duty, 230 volt ac - 03 nos (h) power contractor 12.5 kvar tp cap duly 230 vac -03 nos.(j) auxillary contact- 4 nc-01 nos 230 vac.(k) add on auxillary contact- 4nc-01 nos 29 note: (i) panel should be cpri approved as per authorised manufacturer workshop and panel drawing to get approval from ge before placing of order (ii) quoted rate shall be deemed to include suitable pcc work, excavation and removal of soil for fixing of apfc panel any type. 30 m&l acsr conductor jumper including alkathin pipe 20mm dia for sleeve purpose and fixing material like as lugs, nut bolt & washer etc. all as specified and directed.note :- jumper length of minimum 0.6 mtr and maximum 1.5 mtr. 31 m&l fabrication, supply & install lt panel job out door type with 3.15 mm thick ms sheet factory made of size not less than (1x0.8x 0.5) mtr and angle iron of size 50 x 50 x5 mm angle iron frame, weather proof ventilated with locking arrangement (for ciw)(a) mccb 4 pole 100 amps 36ka - 1 no.(incoming)(b)mccb 3 pole 63 amps 36 ka 415 volts - 01 nos for amf panel dg set (outgoing)(c) mcb spn 10 amps (for street light)(d) voltmeter with selector switch 0 to 500 volts 1 no. (e) indicating lamps with assembly - 3 nos.(f) aluminium bus bar 200 amps capacity for 3 phase and neutral 1 set.(g) single phase timer and contactor(h) amp meter ct 0 to 100 , 01 nos.note: (i) panel should be cpri approved as per authorised manufacturer workshop and panel drawing to get approval from ge before placing of order (ii) quoted rate shall be deemed to include suitable pcc work, excavation and removal of soil for fixing oflt panel any type. 32 m&l fabrication, supply & install lt panel job out door type with 3.15 mm thick ms sheet factory made of size not less than (1.2x1.0x0.5) mtr and angle iron of size 50 x 50 x 5 mm angle iron frame, weather proof ventilated with locking arrangement (main panel for tb2)(a) mccb 400 amps 4pole 36 ka - 01 no.(i/c) (b) mccb 4 3ole 315 amps 25 ka 415 volts - 01 no. (outgoing for amf panel) (c) mccb 3 pole 160 amps 25 ka -01 nos. (outgoing for apfc panel) (d) voltmeter with selector switch 0 to 500 volts 1 no. (e) indicating lamps with assembly - 3 nos. (h) aluminium bus bar upto 600 amps for 3 phase and neutral 1 set. (f) amp meter - ct 0 to 100, 01 nos.note: (i) panel should be cpri approved as per authorised manufacturer workshop and panel drawing to get approval from ge before placing of order (ii) quoted rate shall be deemed to include suitable pcc work, excavation and removal of soil for fixing oflt/ apfc panel any type. 33 m&l fabrication, supply & install lt panel out door type with 3.15 mm thick ms sheet factory made of size not less than (1.2 x 1.0 x 0.5) mtr and angle iron of size 50 x 50 x 5 mm angle iron frame, weather proof ventilated with locking arrangement (for tb2 distribution panel) (a) mccb 4 pole 350 amps 36ka - 1 no.(incoming) (b)mccb 3 pole 315 amps 25 ka 415 volts - 01 nos (for eqpt panel (outgoing) (b)mccb 3 pole 100 amps 16 ka 415 volts - 01 nos (for vtpn dbs. (outgoing) (c) mcb spn 10 amps (for street light) (d) voltmeter with selector switch 0 to 500 volts 1 no. (e) indicating lamps with assembly - 3 nos. (f) aluminium bus bar up to 600 amps for capacity for 3 phase and neutral 1 set. (g) single phase timer and contactor (h) amp meter ct 0 to 100a-01 nos.note: (i) panel should be cpri approved as per authorised manufacturer workshop and panel drawing to get approval from ge before placing of order (ii) quoted rate shall be deemed to include suitable pcc work, excavation and removal of soil for fixing oflt panel any type. 34 s&f led street light fitting 36 watt each with cast aluminium housing, toughened glass, outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection and wired with accessories complete all as specified and directed. 35 s&f sheet moulding compound junction each (smc) suitable for terminating 2 nos 2 x 6 sqmm ug cable including cable glandes- 2 nos, and two way connector 1 no, size 6 x6 including mcb sp 10 amps10 ka complete all as specified and directed. 36 s&f gi pipe bracket with suitable clamps on existing pole made of ms flat 40x5mm and 40mm gi pipe (light grade) bend to 1.5 mtr in length& in any shape with all fixing arrangement, nuts, bolts and washers etc and including 2.5m copper conductor cable multistranded of 2.5sqmm pvc cable from overhead line to fitting connecting box etc complete and all as directed by engr-in-charge and including dismantling the rusted/ broken u/s old one. 37 m&l platform for installation of transformer size 2m x 2m x 1.50m by brick work with subclass b brick construction in cement motor 1:6, hardcore of gauge not exc. 63mm, filling moorum/red bajri in foundation, pcc 1:2:4 type b2 as in floor and 15mm thick on fair faces of brick work or concrete surfaces and earth work in getting any type of soil including two coated of antifungal paint (apex) over plaster surface complete all as specified and directed. 38 m&l chain link fencing of each job size 09 x 11 x 2.15 mtr rolled mild steel work of angle iron fixed independently for fencing post and others confirming to grade fe 410-a including cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts including tmt steel bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete for support of chain link fencing all as specified and as directed. 39 supply install testing and commissioning factory made cpri approved indoor type lt panel wall mounted self supporting compartmentalised design of suitable size not less than 1.2 mtr x 1 mtr x 0.3 mtr 440 volts 3 phase 4 wire system powder coating provided with suitable to make it dust/vermin proof. the panel shall be made with 2mm thick crca sheet for outer shell and inner shell made out of 1.6mm thick crca sheet double door with front openable with locking arrangement proving of threaded earthing stud at the bottom, inner shell be compartmentalised front openable single door system lockable. inner shell completely vermin proof and extension links. aluminium bus bar of capacity 200 amps -04 nos including neutral duly insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size/rating of epoxy resing insulator all housed in suitable bus bar chamber. all control wires shall be with 2.5 sqmm multi stranded copper conductor and shall be properly bunched tied, ferruled for proper identification and crimped with adequate size of lugsincomer: (a) mccb four pole 315 amp 25 ka. ics=100% icu 415v ac - 01 nos.out going. (a) mcb tpn 32 amps-08 nos. (outgoing for motion simulator) (b) mcb spn 32 amps- 16 nos. (outgoing for 16 amp socket 32 nos.) (c) voltmeter 0 to 500 volts size 96x96 sqmm flush mounted three phase with selector switch 01 nos. (d) ammeterch 0 to100 amp of size 96x96 sqmm flush mounted three phase with selector switch & suitable ratio of cts complete -01 nos. (e) led type ryb indicating lamps with back up hrc fuse - 3 nos. (f) aluminium bus bar upto 600 amps for 3 phase and neutral 1 set. 40 note (i) panel should be cpri approved as per authorised manufacturer workshop and panel drawing to get approval from ge before placing of order(ii) quoted rate shall be deemed to include suitable pcc work, excavation and removal of soil for fixing oflt panel any type. 41 supply, install, testing and commissioning of silent diesel engine generating set, 250 kva/225 kw (3-ph), water cooled, powered with engine developing minimum 126.5 bhp at 1500 rpm, coupled with 415 v, 50 hz, 3 phase, 0.8 p.f. suitable alternator, 12v battery with arai approved acoustic enclosure & compliance to cpcb-iv norms along with mccb based amf logic control panel & smps battery charger, tools and spares complete all as specified and directed and comprising of the following:-(a) engine: diesel engine, 4 cylinder engine developing required minimum 126.5 bhp 1500 rpm for prime rating of suitable for 250 kva alternator confirming to bs 5514/180 3046 and revised editions as applicable standard totally enclosed, electric star, compression ignition, 4 stroke. the engine shall consists of following specifications:-1.mechanical fip2.mechanical governor3.turbocharger, exhaust manifold, stainless steel exhaust flexible connection4.radiator cooled with after cooled5.plate type lube oil coolerfilter-fuel, lube oil6.dry type replaceable paper element air cleaner7.flywheel housing and flywheel to suit single bearing alternator8.starting motor- electric, battery charging alternator9.first fill lube oil and coolant(b) alternator: alternator rated 250kva, 0.8 pf, 415 v, 3 phase 4 wire 4 pole, 50hz with standard design band of voltage regulation +/-1% from no load to full load and comprising of following specifications:-1.brushless alternator 42 2.self-excited, self regulated3.class h insulation4.sallent pole revolving field5.single bearing sealed type6.automatic voltage regulator(c) acoustic enclosure: engine alternator assembly mounted on avm with silencer and s.s exhaust bellow suitably optimized to meet stringent sound emission standards as laid down by moef/cpcb. base rail with draw-out type fuel tank with capacity 250 ltr is provided with a drain plug air vent inlet and outlet connections, level indicator, manhole etc. sub-base fuel tank with 13 hours capacity at 75% load. 12 v 180 ah dry, batteries with connecting leads and terminals complete. (d) control panel: powder coated control panel manufactured with crca sheet provides:1.mccb of suitable rating with overload and short circuit protection2.controller which displays voltage, current, kw, pf, frequency, kwh.3.indicating lamps for load on and set running4.current transformers of suitable ratings5.copper cable of suitable capacity with incoming and6.outgoing terminations7.control fuses duly wired and ferruled.(e) power cables: uninyvin copper conductor cables between alternator & control panel inside the canopy (f) electrical systems: alternator space heater/higher rating battery: battery charger/copper bus bar/sealable kwh/earth fault relay/remote annunciator/remote monitoring/type rtd/btd temperature scanner 43 g) exhaust silencer - hospital/residential grade, stainless steel, flexible pipe. fuel system: flexible fuel lines/ss fuel lines/fuel pressure gauge enclosed unit sound enclosure - super silent/external 990 lt fuel tank. miscellaneous: air cleaner (heavy duty)/air cleaner restriction indicator digital/closed crankcase ventilation.(h) amf & synchronizing system: amf panel/amf with auto-synchronization with all necessary control units, mccbs/contactors, mcbs etc complete set ready to operate including necessary cable connections.(j) generator control: the generator control consists of1.display parameters: engine oil pressure, coolant temperature, fuel level indication%, battery voltage, engine rpm, dg set running hours, generator volts ph to n, ph to ph, current, pf, kwhr, kw2.audio visual warning: low oil pressure, high coolant temperature, low battery voltage, low fuel level3.shut down with audio visual annunciation: low oil pressure. high coolant temp, engine over speed, engine under speed, low fuel, under voltage, overvoltage, over and under frequency4. other features compact and microprocessor based fully configurable control unit with all necessary wirings, mcbs etc, graphic displaynote: quoted rate shall be deemed to include any other technical requirement items & pcc foundation, excavation, removal of soil if any shall be included and quoted in this item only. 44 supply, install, testing and commissioning of silent diesel engine generating set, 40 kva/36 kw (3-ph). water cooled, powered with engine developing minimum 56 bhp at 1500 rpm, coupled with 415 v, 50 hz, 3 phase, 0.8 p.f. suitable alternator, 12v battery with arai approved acoustic enclosure & compliance to cpcb-iv+ norms along with mccb based amf logic control panel & smps battery charger, tools and spares complete all as specified and directed and comprising of the following: (a) engine: diesel engine 4 cylinder engine developing required minimum 56 bhp @ 1500 rpm for prime rating of suitable for 40 kva alternator confirming to bs 5514/iso 3046 and revised editions as applicable standard totally enclosed, electric start, compression ignition, 4 stroke. the engine shall consists of following specifications1.mechanical fip2.mechanical governor3.turbocharger, exhaust manifold, stainless steel exhaust flexible connection4.radiator cooled with after cooled5.plate type lube oil cooler6.filter-fuel, lube oil7.dry type replaceable paper element air cleaner8.flywheel housing and flywheel to suit single bearing alternator9.starting motor- electric, battery charging alternator10.first fill lube oil and coolant.(b) alternator: alternator rated 260kva, 0.8 pf, 415 v, 2 phase 4 wire 4 pole, 50hz with standard design band of voltage regulation from no load to full load and comprising of following specifications:- 45 1.brushless alternator2.self-excited, self regulated3.class f insulation4.salient pole revolving field5.single bearing sealed type6.automatic voltage regulator(c) acoustic enclosure: engine alternator assembly mounted on avm with silencer and ss bellows suitably optimized to meet stringent sound emission standards as laid down by moef/cpcb. base frame with draw-out type fuel tank with capacity 200 ltr is provided with a drain plug, air vent, inlet and outlet connections, level indicator, manhole etc. sub-base fuel tank with 13 hours capacity at 75% load 12v 180 ah dry, batteries with connecting leads and terminals complete. (d) control panel: powder coated control panel manufactured with crca sheet provided1.mccb of suitable rating with overload and short circuit protection2.controller which displays voltage, current, kw, pf, frequency, kwhindicating lamps for load on and set running3.current transformers of suitable ratings4.copper cable of suitable capacity with incoming and5.outgoing terminations6.control fuses duly wired and ferruled.(e) power cables: unarmour copper conductor cables between alternator & control panel inside the canopy (f) electrical systems: alternator space heater / higher rating battery / battery charger / copper bus bar / sealable kwh / earth fault relay / remote annunciator/remote monitoring / type rtd / btd temperature scanner 46 (g) exhaust silencer - hospital / residential grade, stainless steel, flexible pipe. fuel system: flexible fuel lines / ss fuel lines / fuel pressure gauge. enclosure unit: sound enclosure - super silent / external 800 lt fuel tank. miscellaneous: air cleaner (heavy duty) air cleaner restriction indicator digital / closed crankcase ventilation. (h) amf & synchronizing system: amf panel / amf with auto-synchronization with all necessary control units, mccbs/ contactors, mcbs etc complete set ready to operate including necessary cable connections.(i) generator control: the generator control consists of the1.display parameters: engine oil pressure, coolant temperature, fuel level indicator, battery voltage, engine rpm, dg set running hours, generator volts ph-n, ph-ph, current, pf, kwhr, kva2.audio visual warning: low oil pressure, high coolanttemperature, low battery voltage, low fuel level3.shut down with audio visual annunciation: low oil pressure, high coolant temp, engine over speed, engine under speed, low fuel, under voltage, overvoltage, over and under frequency. other features: compact and microprocessor based fully configurable control unit with all necessary wirings, mcbs etc, graphic display. note: quoted rate shall be deemed to include any other technical requirement items & pcc foundation excavation, removal of soil if any shall be included and quoted in this item only. 47 s&f water cooler electric driven (single phase), having approximately storage capacity of 80 litre and nominal cooling capacity of 40 litres per hour. (1x 02nos for tb2 and 1 x 01nos for ciw) complete all as specified and directed. 48 m&l for laying double wall corrugated (dwc) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to is 16205 & 14930 (part-1 and ii) type 450n, for protection of underground cable of size 40mm outer dia with all fittings such as clamps, coupler, bend etc. laid in trenches/roads/nallah or fixed along wall/ poles or laid under floor (including cutting floor/road and making to match with existing adjouning surface etc. for cable protection all as specified.note : excavatoin and earth work shall bemeasured and paid separately. 49 all as per item no. 17.70 here-in-before but of size 63mm outer dia, complete all as specified and directed. 50 all as per item no. 17.70 here-in-before but of size 120mm outer dia, complete all as specified and directed. 51 all as per item no. 17.70 here-in-before but of size 160mm outer dia, complete all as specified and directed.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 8862fc0c-84a6-4f36-a1c9-e100f6ee18ab
Download Acceptanceltr
Download boqcomparativechart
Download finance_824791
Download finsummary_824791
Download technical_824791
Download techsummary_824791
Download File Name File Description
Download TD2 Tender Documents
Download Tendernotice_1 Tender Documents
Download BOQ_824791 Tender Documents
Download MainDrg Tender Documents
Download TD1 Tender Documents
Download a8ce796d-fc89-4fdc-9e89-71e491bd3a49 Tender Documents
Download 84604-TENDER-UPLOAD Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders