BRR : 8506879
Tender Brief : Tender For Running Contract For Deposit Works Under Edd-Ii, Bareilly, 1 The work of safe carriage of the following material from CB Ganj store center to work siteunder the jurisdiction of EDD-II, Bareilly. Approx. distance upto 80 Km. Including safe loading and unloading. 2 PCC Pole 8.5 meter long. 3 STP 9 Mtr Long 4 STP 11 Mtr Long 5 Other Line material (Except Pole) i.e., cross arm/ conductor/ pin insulator/stay/earthing rod/Disc Fitting/Disc Insulators/11 KV XLPE/LT XLPE Cable etc 6 11/0.4 KV 1 Phase 10/16 KVA T/F 7 11/0.4 KV 3 Phase 25 KVA T/F 8 11/0.4 KV 3 Phase 63 KVA T/F 9 11/... Read More
Tender Value
₹
1,40,00,000
Contract Value
₹ 1,10,58,873.28
Saving / Difference
₹ 29,41,127
▲
Submission Date
24-06-2024
Contract Date
27-03-2025
Completion Date
365 days
Participated Bidder List
5 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 1,45,77,487 | L3 | |||
| 2 | cnet-technologies | Bid Analytics | 1,26,00,000 | L2 | |||
| 3 | cnet-technologies | Bid Analytics | 1,10,58,873.28 | L1 | |||
| 4 | cnet-technologies | Bid Analytics | 1,58,33,246 | L4 | |||
| 5 | cnet-technologies | Bid Analytics |
Work Detail
tender for running contract for deposit works under edd-ii, bareilly, 1 the work of safe carriage of the following material from cb ganj store center to work siteunder the jurisdiction of edd-ii, bareilly. approx. distance upto 80 km. including safe loading and unloading. 2 pcc pole 8.5 meter long. 3 stp 9 mtr long 4 stp 11 mtr long 5 other line material (except pole) i.e., cross arm/ conductor/ pin insulator/stay/earthing rod/disc fitting/disc insulators/11 kv xlpe/lt xlpe cable etc 6 11/0.4 kv 1 phase 10/16 kva t/f 7 11/0.4 kv 3 phase 25 kva t/f 8 11/0.4 kv 3 phase 63 kva t/f 9 11/0.4 kv 3 phase 100 kva t/f 10 11/0.4 kv 3 phase 250 kva t/f 11 11/0.4 kv 3 phase 400 kva t/f 12 11 kv pilfer proof metering cubical and ct pt unit 13 33 kv pilfer proof metering cubical and ct pt unit 14 33 kv line isolator 800 amp 15 33 kv vcb 800 a, 750 mva 16 33 kv control panel for single transformer 17 33 kv control panel for double transformer 18 11 kv bus cupler 19 33 kv ct 200/100/1-1a 20 33 kv lightening arrestor 21 erection of new pcc single/double pole in h.t/l.t lines including fitting of all accessories as per resspo norms 22 pcc pole 8.5 mtr long single pole 23 pcc pole 8.5 mtr long double pole 24 st pole 9 mtr long single pole. 25 st pole 9 mtr long double pole. 26 st pole 11 mtr long single pole. 27 st pole 11 mtr long double pole. 28 grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/bb & sand required as per resspo norms 29 pcc pole 8.5 mtr long single pole 30 pcc pole 8.5 mtr long double pole 31 st pole 9 mtr long single pole. 32 st pole 9 mtr long double pole. 33 st pole 11 mtr long single pole. 34 st pole 11 mtr long double pole. 35 the work of driving the earthing electrode and making connections with 6 s.w.g. gi wire as per resspo norms 36 dismantling of old and damaged conductor complete in all respect 37 dismantling of pcc/st pole due to line shifting/damaged complete in all respect 38 dismantling of existing distribution transformer for increasing capacity/shifting complete in all respect 39 11/0.4 kv 3 phase 25 kva t/f 40 11/0.4 kv 3 phase 63 kva t/f 41 11/0.4 kv 3 phase 100 kva t/f 42 11/0.4 kv 3 phase 250 kva t/f 43 11/0.4 kv 3 phase 400 kva t/f 44 laying, stringing & sagging of following conductor complete in all respect 45 acsr weasal conductor 46 acsr rabbit conductor 47 acsr dog conductor 48 3 phase arial bunched conductor 49 1 phase arial bunched conductor 50 lt xlpe 1x630 sqmm 51 lt xlpe cable 3.5x70 sqmm 52 after mounting of ct pt unit on double pole, laying of 50 mtr 11 kv 3cx70 sq mm cable in single circuit on river sand formdouble pole to metering room complete in all respect. alongwith filling ofcable jointing kits 53 after mounting of ct pt unit on double pole, laying of 50 mtr 33 kv 3cx120 sq mm cable in single circuit on river sand formdouble pole to metering room complete in all respect. alongwith filling ofcable jointing kits 54 under ground laying of following cable in single circuit on river sand to double pole situated at both sides of road complete in all respect. minimum depth should be 0.75 mtr and cable should be covered by bricks from three sides. alongwith filling ofcable jointing kits 55 11 kv xlpe cable size 3x70 sqmm 56 11 kv xlpe cable size 3x120 sqmm 57 11 kv xlpe cable size 3x185 sqmm 58 33 kv xlpe cable size 3x120 sqmm 59 33 kv xlpe cable size 3x185 sqmm 60 33 kv xlpe cable size 3x300 sqmm 61 under ground laying of following cable in single circuit by drill method to double pole situated at both sides of nh/sh/railway crossing complete in all respect.alongwith filling ofcable jointing kits 62 11 kv xlpe cable size 3x70 sqmm 63 11 kv xlpe cable size 3x120 sqmm 64 11 kv xlpe cable size 3x185 sqmm 65 33 kv xlpe cable size 3x120 sqmm 66 33 kv xlpe cable size 3x185 sqmm 67 33 kv xlpe cable size 3x300 sqmm 68 hoisting of following size 11 kv & 33 kv xlpe cableon double pole with gi pipe of size 6 dia 4 mtr long including the jumpering complete with clamps , nut and bolts. 69 11 kv xlpe cable size 3x70 sqmm 70 11 kv xlpe cable size 3x120 sqmm 71 11 kv xlpe cable size 3x185 sqmm 72 33 kv xlpe cable size 3x120 sqmm 73 33 kv xlpe cable size 3x185 sqmm 74 33 kv xlpe cable size 3x300 sqmm 75 filling of 11 kv outdoor cable boxes for 3x185 sqmm xlpe cable 76 supply & laying of 6 dia g pipe at various places i.e road crossing & hoisting etc. complete in all respect ((iso certified gi pipe 150 nb 3 mm thick dia 6 would be provided by contractor at his own cost) 77 supply & laying of 140 mm od pn-4 pe-80 grade uv sabilized hdpe pile as per is 4984 in 6 meter (would be provided by contractor through approved vendors of discom at his own cost) 78 construction of t/f plinth 1.5x1.5x2 m3 for mounting 250/400 kva t/f including foundation work (below ground 0.5 m), brick work, rcc slab of 4” thickness and plastering in 1:6 ratio with 02 nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect all manpower, material and t&p provided by the contractor to complete the work. 79 cage fencing of 250/400 kva plinth mounted transformer in town areas to avoid electrical human/cattle accidents by fabrication of cage (1 inch sq wiremesh) made of 10 no gauge in suitable size angle iron frame of size 7.5(l)x5(w)x8’(h) by strengthening of wire mesh 20x3 mm m.s. flat horizontally as well as vertically, grouting the panel with 1:2:4 cement/coorse send/brick ballast. the frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. provision of 1 gate should be there for maintenance of the transformer. painting (1 coat of red oxide + 2 coat of bus green enamel paint). the wire mesh should be earthed with 50x6 mm ms earthing strip with existing earthing of transformer body. all manpower, material and t&p provided by the contractor to complete the fabrication, transportation and installation. 80 the work of digging of pits, erection of stay clamp, insulator etc. 81 grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per respo norms. 82 installation of 11 kv fuse set 83 fixing of 11 kv tpmo 84 installation of 11 kv pilfer proof metering cubicle in metering room complete in all respect 85 installation of 33 kv pilfer proof metering cubicle in metering room complete in all respect 86 installation of lt incoming panele with metering eauipment & fixing arrangement for lt circuit deistribution complete in all respect as per norms 87 mounting of following capacity transformers as per norms complete in all respect - 88 10/16 kva t/f 89 25 kva t/f 90 63 kva t/f 91 100 kva t/f 92 250 kva t/f 93 400 kva t/f 94 fixing of distribution box complete in all respect 95 guarding at road crossing complete in all respect 96 fixing of following material as per norms complete in all respect 97 33 kv line isolator 800 amp 98 33 kv vcb 800 a, 750 mva 99 33 kv control panel for single transformer 100 33 kv control panel for double transformer 101 11 kv bus cupler 102 33 kv ct 200/100/1-1a 103 33 kv lightening arrestor 104 plinth & foundation for 33 kv vcb as per norms complete in all respect 105 supply & fixing of following items to complete the work (provided by the contractor through approved vendon of discom/uppcl, if not available in stores) 106 lt clamps as per resspo norms for pcc/st pole 107 nut & bolt off size 108 f clampas per resspo norms 109 shackle insulatoras per resspo norms 110 x-arm holding clampas per resspo norms 111 holding clamp for t-off 112 holding clamp for g i pipe 113 clamps with nut & bolt for top & dropper channel 114 stay clampsas per resspo norms 115 11 kv composite polymer disc insulatoras per resspo norms 116 top channel of size 100x50x2240 mmas per resspo norms 117 t off channelas per resspo norms 118 11 kv pin insulator as per resspo norms 119 11 kv pin insulator with pin & nut as per resspo norms 120 11 kv pin with nut as per resspo norms 121 11 kv disc insulator with fitting 122 stone pad 123 11 kv steel x arm v-type 124 danger board 125 danger board barbed wire including jumper 126 aluminium paint 127 red oxide paint 128 barbed wire 129 lt shackle insulator 130 pg clamp 131 11 t-off (125x65x1300mm) 132 11 kv disc fittingwith insulator (45 kn (t&c type) 133 guarding angle 65x65x6 mm 1.6 mtr long 134 clamp for guarding angle with nut & bolt 135 gi wire 6 swg & 10 swg for guarding & lacing 136 nut & bolt with washer 137 ms angle iron 65x65x6 mm, 2700 mm long bracing with 4 clamp 138 j-huck 139 suspenstion clamp 140 piercing connector 141 al lug 630 sqmm 142 safe back carriage of scrap (if any) from work siteto c.b. ganj store bareilly approx distance upto 80 km including safe loading & unloading. 143 safe back carriage of distribution transformer from work siteto c.b. ganj store bareilly approx distance upto 80 km including safe loading & unloading. 144 11/0.4 kv 3 phase 25 kva t/f 145 11/0.4 kv 3 phase 63 kva t/f 146 11/0.4 kv 3 phase 100 kva t/f 147 11/0.4 kv 3 phase 250 kva t/f 148 11/0.4 kv 3 phase 400 kva t/f 149 cutting of tree branches
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results