BRR : 8237686
Tender Brief : Tender For Special Repair Of Bldg No T-67 Of 328 Med Regt At Nurla Mil Stn Under Age (I) Nimu; 1 Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness including cover fillets 2 Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position as in unframed work 3 S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side withdecorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in Ceilling ... Read More
Tender Value
₹
9,73,000
Contract Value
₹ 9,25,050
Saving / Difference
₹ 47,950
▲
Submission Date
20-09-2025
Contract Date
11-11-2025
Completion Date
180 days
Participated Bidder List
2 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 10,11,619.75 | L2 | |||
| 2 | cnet-technologies | Bid Analytics | 9,25,050 | L1 |
Work Detail
tender for special repair of bldg no t-67 of 328 med regt at nurla mil stn under age (i) nimu; 1 dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness including cover fillets 2 dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position as in unframed work 3 s&f 9mm thick prelaminated particle board, interior grade, prelaminated one side withdecorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in ceilling complete all as specified and directed by engr-in-charge. 4 m & l plain fillets. exc. 13 & n.exc 25 sq cm as in square, rectangular or triangular in section, clean sawn, secured with nails or brads. 5 ditto, but exc 3 & n.exc 6 sq cm in bullnosed, splayed, chamfered or rounded on one edge or face as in bedding 6 taking down chowkhats or frames exc 1.5 sqm but not exc. 4 sq. m each(without taking off shutters from the frames) complete all as specified and directed by engr-in-charge. 7 all as per item above heer-in-before but n.exc 1.5 sqm(without taking off shutters from the frames) complete all as specified and directed by engr-in-charge. 8 m&l 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed by engr-in-charge. 9 m&l 2nd class hardwood 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats for doors complete all as specified and directed by engr-in-charge. 10 m&l 2nd class hardwood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in ssr part i, section 8, clause 8.24 (a); supplied and fitted to chowkats for doors complete all as specified and directed by engr-in-charge. 11 all as per item above heer-in-before but 30mm thickcomplete all as specified and directed by engr-in-charge. 12 all as per item above heer-in-before butdivided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, all as specified and directed by engr-in-charge. 13 m&l for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats ofsynthetic enamel (ordinary tint)complete all as specified and directed by engr-in-charge 14 s&f mild steel butt hinges 100mm, medium weight, cold rolled mild steel,complete all as specified and directed 15 all as per item above heer-in-before but 75mmcomplete all as specified and directed by engr-in-charge. 16 s&f extruded aluminium alloy handles, fabricated type, anodised 150mm long complete all as specified and directed by engr-in-charge. 17 all as per item above heer-in-before but 100mmcomplete all as specified and directed by engr-in-charge. 18 s&f mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and directed by engr-in-charge. 19 s&f aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long (isi marked), complete all as specified complete all as specified and directed by engr-in-charge.. 20 all as per item above heer-in-before but 100mmcomplete all as specified and directed by engr-in-charge. 21 m&l for preparation of new wood surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats ofsynthetic enamel (ordinary tint) over a coat of pink primer complete all as specified and directed by engr-in-charge. 22 m&l for preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats ofsynthetic enamel (ordinary tint)complete all as specified and directed by engr-in-charge 23 s & f 3mm th sheet glass, ordinary quality and glazing with wooden beading in squares n exc 0.5 sq. m in each pane all as specified and directed by engr-in-charge. 24 dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings. 25 s & f galvanised, corrugated mild steel sheeting0.63 mm thifck with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 as in roof covering/ cladding to wall, fixed with self tapping screws as specified 26 all as per item above heer-in-before butexcept sheeting (any thickness)complete all as specified and directed by engr-in-charge. 27 s & f plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 as in roof covering/ cladding to wall, fixed with self tapping screws as specified 28 all as per item above heer-in-before butexcept sheeting (any thickness)complete all as specified and directed by engr-in-charge. 29 m&l for preparing new zinc (or galvanised) surfaces to receive painting, by coating with mordant solution including washing and cleaning, etc. of any description, over 10cm in width or girth,not otherwise described and applying two coats ofsynthetic enamel (ordinary tint) paing over a coat of red oxidecomplete all as specified and directed by engr-in-charge 30 demolition of pcc (un-reinforced) in ground floors & pavings n.exc 15 cm thickness below or above ground level, complete all as specified and directed. 31 m & l for cement concrete type d-2, 1:4:8 (using 40mm aggregate) 75mm thick as in sub base of flooring complete all as specified and directed. 32 all as per item above heer-in-before but type c-2, 1:3:6 (using 40mm aggregate) 75mm thick as in plinth protection complete all as specified and directed. 33 all as per item above heer-in-before but type b-1, 1:2:4 (using 20mm aggregate) 50mm thick as in plinth protection complete all as specified and directed. 34 dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. 35 s&f roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beams, tee, angle, channel or flat sections) including distance piece, cleats etc fe 410-w (gde - e - 250) quality a.all as specified and directed by engr-in-charge. 36 taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc 37 m&l repair for point wiring with pvc insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid pvc casing caping accessories lain on wall/ceiling surface and fixed with pvc saddles and back-plate and gi screws, including pvc insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and pvc board for housing like switches, sockets, fan regulators etc all as directed for following :-(a) one light point/one fan point controlled by one switch 38 m&l repair for point wiring with pvc insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid pvc casing caping accessories lain on wall/ceiling surface and fixed with pvc saddles and back-plate and gi screws, including pvc insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and pvc board for housing like switches, sockets, fan regulators etc all as directed for following :-(b) one 3 pin 5 amps socket outlet independent with cables 1.5 sqmm size 39 m&l repair for point wiring with pvc insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid pvc casing caping accessories lain on wall/ceiling surface and fixed with pvc saddles and back-plate and gi screws, including pvc insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and pvc board for housing like switches, sockets, fan regulators etc all as directed for following :-(c) one 3 pin 5 amp socket outlet on same board. 40 all same as per item no 38 above but with conductor of size 4 sqmm (nominal area) for one 3 pin socket outlet 15 amps on independent board complete and earth continuity wire with 4 sqmm pvc insulated stranded copper conductor cablecomplete as specified and as directed by engr in charge. 41 s&f repair socket 2 in 1, 5 pin 5 amp flush type complete all as specified. 42 s&f repairswitch piano flush type 5 amp, single pole, one way complete all as specified and directed. 43 s&frepair switch socket combination 2 in 1, 3 pin, 5 amp flush type complete all as specified and directed. 44 s&f in repair switch socket combination 2 in 1, 3 pin, 15/16 amp flush type universal complete all as specified and directedcomplete as specified and as directed by engr in charge. 45 m&lin repair for ceiling rose surface bakelite 65x50mm two to three terminal complete all as specified and as directed by engr-in-charge. 46 s&fin repair basic all purpose surface and wall mounted led batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long,with all accessories complete all as per specified and as directed by engr-in-charge. 47 s & f led light fitting 1x9w/1x10w bulkhead luminaires including led light driver holder connecting up with three core flexible copper conductor cable of suitable size. 48 supply and fixing led flood light 70 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection, with impact and corrosion resistant complete with driver and lamp complete as specified and as directed by engr in charge. 49 s&fin repair sheet metal powder coated versatile double door spn distribution board,12 way suitable for mcbs fitted with copper bus bar rated 200amps, neutrallink , earth bar and din rail suitable for use on 240 volt, 50hzcomplete as specified and as directed by engr in charge. 50 m&lin repair for mcb spn 63 amp, 240v with 10ka breaking capacity of c series in distribution boardscomplete as specified and as directed by engr in charge. 51 s&f in repairs to mcb sp 6-32 amp with 10ka breaking capacity of c series in distribution boardscomplete as specified and as directed by engr in charge. 52 supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape armoured with galvanised steel wire or tape and overall pvc sheathed 10 sq. mm twin core nominal cross section in service connectionscomplete as specified and as directed by engr in charge. 53 dismantiling and taking down old u/s street / building security light fittings from poles,flood light post top lantern lights and garden lights for replacement with led fittings all as specified and as directed by engr in charge. 54 supply and fixing in repair led street light fitting 60 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete as specified and as directed by engr in charge. 55 m&l for gi bracket 1.5 mtr long made out gi pipe 40mm dia bend to suitable radius incl clamps nuts bolts washers incl painting with aluminum paint etc complete all as specified and directed by engr in charge. 56 m&l for one point wiring controlled by one switch withaluminium conductorcable of 1.5 sqmm pvc sheathed cable and all fiting in pvc conduitfor security light all as specified and directed by engr in charge. 57 m&l for busbar chambers with 4 aluminium busbar strip of rating 400 amp 6 way fixed on angle iron of size 40mm x 40mm x 5mm complete all as specified and directed by engineer in charge. 58 earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt,connected to galvanized earh lead wire of size 4.0 mm dia by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in electrical plate no. 3, wire protected by dia 15 mm bore light grade gi pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia gi light grade including wire mesh funnel, pcc, earth chamber pit with pcc 1:2:4 type b-1 using 20 mm grade stone aggreate including form work cement mortar including ci pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired resultcomplete as specified and as directed by engr in charge.note- 01 earthing for db, and another is forbus bar,
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results