BRR : 8150233
Click Here To View Tendering Authority. Aoc City/State :  hardoi, Uttar Pradesh
Tender Brief : Tender For Construction Work Of Building For Public Use In Development Block Hariyawan - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per SI.No. 2.8.1 2 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical em... Read More
Tender Value
12,71,000
Contract Value
₹ 12,69,134.16
Saving / Difference
₹ 1,866 ▲
Submission Date
08-09-2025
Contract Date
25-10-2025
Completion Date
90 days
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 12,69,769.68 L2
2 cnet-technologies Bid Analytics 12,69,134.16 L1
Work Detail
tender for construction work of building for public use in development block hariyawan - earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds of soil as per si.no. 2.8.1 2 diluting and injecting chemical emulsion for post-constructional anti-termite treatment (excluding the cost of chemical emulsion) treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 coarse sand) to match the existing floor: with chlorpyriphos/lindane e.c. 20% with 1% concentration as per si.no. 2.35.3.1 3 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (under floor) as per si.no. 2.25 (a) 4 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) as per si no. 4.1.8 5 brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) as per si no- 6.1.2 6 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level in :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) as si no-5.1.2 7 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) upto plinth lvl as si no-5.1.2 8 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)above plinth lvl as si no-5.2.2 9 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) upto plinth lvl as si no-5.1.2 10 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-iii)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). above plinth lvl as si no-5.3 11 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per si no. 5.3 12 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (slab) as per si no. 5.3 13 steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete in thermo-mechanically treated bars of grade fe-500d or more. as per si. no.- 5.22 b.1 14 brick work with common burnt clay bricks of m-150 class in super structure above plinth level upto floor v level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) as per si no 6.4.2 15 steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.in grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per si no. 10.25.2 16 providing and fixing factory made upvc white colour casement/casement cum fixed glazed windowscomprising of upvc multi-chambered frame, sash and mullion (where ever required) extruded profilesduly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process ofrequired length (shape & size according to upvc profile), upvc extruded glazing beads of appropriatedimension, epdm gasket, stainless steel (ss 304 grade) friction hinges, after fixing frame the gap between frame and adjacent finished wall. dsr 9.147a 17 providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of size 595x595mm of approved texture, design and patterns as per cpwd specification 2019, to be laid in true horizontal level 18 15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) inner side as per is 13.5.2 19 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) outer side as per is 13.4.2 20 15 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand )below plinth as per is 13.5.1 21 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. as si no. 11.3.1 22 providing and fixing 1st quality ceramic glazedwall tiles conforming to is : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. as per si no. 11.37 a 23 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm as per si no 11.41.2 24 distempering with 1st quality acrylic distemper (ready mixed) having voc content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : new work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 gram/litre as per sl no. -13.41.1 two coats 25 finishing walls with acrylic smooth exterior paint of required shade: new work (two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per sl no. -13.46.1 two coats 26 providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface as per sl no. -13.80 27 providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer-in-chargewith average thickness of 120 mm and minimum thickness at khurra as 65 mm. as per si no. -22.7.1 28 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes.110 mm diameter. as per si- 12.41.2 29 centering and shuttering including stutting, propping etc. and removal of form.beam /band as per si- 5.9.5 30 centering and shuttering including stutting, propping etc. and removal of form.column as per si- 5.9.6 31 centering and shuttering including stutting, propping etc. and removal of form.foundation as per si- 5.9.1 32 centering and shuttering including stutting, propping etc. and removal of form.slab as per si- 5.9.3 33 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 34 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 35 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 36 add for invertor wiring in wiring point for light/fan/plug with 1.5 mm cu wire. 37 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required. 38 supplyingandfixingsuitablesizegiboxwithmodularplateandcoverinfronton surfaceorinrecess,includingprovidingandfixing6pin5/6&15/16amodular socket outlet and 15/16 a modular switch, connections etc. as required. 39 supply and fixing ofled tube light batten fittingsuitable for up to 1 x 22 watt led tube light on surface complete in all respect. - cat-aaa 40 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cm/m/w) minimum 6.00,air deliveryminimum 210 cum/min , 350 rpm (tolerance as per is : 374-2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase acsupply, earthing etc. complete as required. 41 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 42 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 4 way (4 + 12), double door 43 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.6 way (4 + 18), double door 44 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. double pole 45 supply and laying of aluminium conducter, pvc insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on m.s. clamps etc. of suitable size. or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 50 sq. mm 3-1/2 core
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download e0f27cd9-e3af-4874-adf2-fe46bc982cd1
Download 82
Download boqcomparativechart
Download finance_1952264
Download finsummary_1952264
Download technical_1952264
Download techsummary_1952264
Download File Name File Description
Download Tendernotice_1 Tender Documents
Download c5cc6a82-458f-4f2a-ba9f-518da50bc80e Tender Documents
Download BOQ_1952264 Tender Documents
Download SBD Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000