BRR : 10342237
Click Here To View Tendering Authority. Price Bid City/State :  hapur, Uttar Pradesh
Tender Brief : Replacement Of Jarjar Pole, Ab Cable, Conductor, 11Kv Cable, Pole And Other Mix Work In Business Plan 2025-26 22 No. Work In The Jurisdiction Of Edd-Hapur, Under Edc., Hapur.- 1 Carriage of all petty material of estimate, from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge from JE Store/Store center Hapur/Ghaziabad/Bulandshar (0-50 Km) 2 Carriage of following material from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Ka... Read More
Tender Value
35,05,000
Submission Date
30-09-2025
Participated Bidder List
5 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 32,68,039 L1
2 cnet-technologies Bid Analytics
3 cnet-technologies Bid Analytics 33,64,097 L2
4 cnet-technologies Bid Analytics 33,64,700 L3
5 cnet-technologies Bid Analytics
Work Detail
replacement of jarjar pole, ab cable, conductor, 11kv cable, pole and other mix work in business plan 2025-26 22 no. work in the jurisdiction of edd-hapur, under edc., hapur.- 1 carriage of all petty material of estimate, from electricity store center, hapur to 33/11kv sub-station/site of work with loading and unloading at both ends on kachha packka road, as per direction of site incharge from je store/store center hapur/ghaziabad/bulandshar (0-50 km) 2 carriage of following material from electricity store center, hapur/j.e. store to site of work with loading and unloading at both ends on kachha packka road, as per direction of site incharge from je store/store center hapur/ghaziabad/ bulandshar (0-50 km). 3 (a) pcc pole 11 mtrs. long 4 (b) pcc pole 8.5 mtrs. long 5 erection & fixing of following polein 11 kv line after digging of suitable pits including fixing of requisite all accessories as per respo drawing/norms by providing f-bracket and holding clamps made of m.s. flat of size 50x6 mm with proper size nuts and bolts., as per direction of site incharge. 6 (a) pcc pole 8.5 mtr. long 7 (b) pcc pole 11 mtr. long 8 erection & fixing of pcc pole 8.5 mtr. longin lt. line after digging of suitable pits including fixing of requisite accessories as per respo drawing/norms by providing l.t. pin clamps, m.s. flat of size 50x6 & schacle insulator of size 75x90mm, with proper size nuts and bolts,as per direction of site incharge. 9 erection of double pole structure with all accessories on following pole fabrication and fixing of m.s. top & dropper channel, m.s. t/f angle, e-bracket, 11 kv pin insulator with pin,disc insulator with disc fitting etc., as per respo drawing/norms by providing all clamps made of m.s. flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, as per direction of site incharge. 10 (a) pcc pole 11 mtr. long 11 laying of 140/160mm o/d pn-4pe-80 pn-4 grade uv stabilized hdpe pipe as per is of 6meter, for laying of undergroundcable as per respo/norms, including cost of above hdpe pipe, as per direction of site incharge. (rate will be charge as per actual length of work) 12 laying offollowing xlpe cable undergound into hdpe pipe, spare cable shall be left in the loop shape at both ends as per respo/norms, as per direction of site incharge.(rate will be charge as per actual length of work) 13 (a) 11 kv xlpe cable of size 3x70/3x120/3x185/3x240/3x300 sq.mm 14 laying of 11kv xlpe cable 3x70, 3x120, 3x185, 3x300 sq.mm overhead and completion work properly, as per respo/norms, and as per direction of site incharge.(rate will be charge as per actual length of work). 15 laying of lt abc of various size and complete work properly,as per respo/norms, and as per direction of site incharge.(rate will be charge as per actual length of work). 16 providing and fixing of suspension clamp with eye hook as per respo/norms and as per direction of site incharge. 17 providing and fixing of dead end clamp with eye hook, as per respo/norms and as per direction of site incharge. 18 making and filling of 11kv cable jointing kit, indoor/outdoor type, after duly plumbing and taping of suitable xlpe cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per respo norms, and as per direction of site incharge. 19 grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per respo drawing/norms by providing all grouting material and stay clamp made of m.s. flat of size 50x6mm with proper size bolts & nuts & loops, as per direction of site incharge. 20 earthing of supports with ms earth rod of (20x2500)mm long including excavation of pit and driving m.s. rod 3.0 m apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of g.i. wire & earthing lugs as per respo drawing/norms by providing proper size nuts & bolts, as per direction of site incharge. 21 grouting of following st/pcc supports in cc 1:3:6 (cement, sand & 40mm brick ballast) grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with cc 1:3:6 (cement, core sand and stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials, as per direction of site incharge. 22 pcc pole 8.5 mtr. long 23 st/pcc pole 11 mtr. long 24 laying , stringing and final sagging of acsr weasel conductor, as per respo/ drawing norms and as per direction of site incharge. 25 laying , stringing and final sagging of acsr dog conductor, as per respo/ drawing norms and as per direction of site incharge. 26 providing & fixing of g.i. pipe 6dia class-b over 11kv/33 kv xlpe cable before mounting the cable at double pole. the work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends, as per direction of site incharge. 27 construction of safety fencing (ms) size 3x3x2 mtr. for transformer 11/0.4 kv sub station, with supply of material required for ms fencing (50x50x3 mm) m.s. wire mesh construction utilizing vertical post duly grouted/fitted in ground/on floor. horizontal angle/t-iron to be fitted on vertical posts. pickets (if required) fitted to rail and gate to facilitate entry and exit. the vertical posts/horizontal post shall be made of m.s. angle 75x75x6mm. such post shall be kept preferably at distance of 800-1000 mm. and shall be grounded with cc ratio 1:4:8. the length of vertical post shall be sufficient to take care of fencing as requirement at site, and as per direction of site incharge. 28 providing & fixing of danger board, including fixing of all accessories by providing all required materials (like suitable clamps, nuts & bolts etc.) as per respo/drawing norms and as per direction of site incharge. 29 providing & fixing of number plate alongwith all required accessories (like suitable clamps, nuts & bolts etc.) as per respo/drawing norms and as per direction of site incharge. 30 safely dismantling work properly and carriage of old & used stp pole & other material from site of work to electricity store center, hapur with loading and unloading at both ends on kachha packka road, as per direction of site incharge. 31 safely dismantling/removal and carriage of old & used acsr conductor from site of work to electricity store center, hapur with loading and unloading at both ends on kachha packka road, as per direction of site incharge. 32 jumpheing work of lt/ht line for proper energization of line. 33 laying of lt pvc cable 1x400/1x240 sq.mm. for connection of distribution transformer. 34 providing and crimping of aluminium lug of diffrance size used in medium power transformer. 35 fixing of 11 kv cross arm on 11 kv pcc pole all ms clamp (50x6 mm) ms sheet and nut bolt provide by contractor. 36 supply and fixing of f- clamp for 11 kv pcc pole made of 50x6 mm m.s. sheet 37 supply and fixing of lt clamp for 8.5 mtr pcc pole all necessary nut bolt for fixing of clamp provide by contractor.
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download c8c9be79-a441-41c5-a572-1efc5ee92345 financialevaluation notice
Download boqcomparativechart boq document
Download finance_1966664 aoc document
Download finsummary_1966664 aoc document
Download File Name File Description
Download Tendernotice_1 Tender Documents
Download f3cbc189-e939-4133-a639-844cd3e3af17 Tender Documents
Download BOQ_1966664 Tender Documents
Download TenderDocument25 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.