BRR : 10022381
Tender Brief : Tender For General - Haripad Municipality Owc Electrification-General Electrical Work; 1 OWC electrification 2 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,r... Read More
Tender Value
₹
1,06,521
Contract Value
₹ 95,974.8
Saving / Difference
₹ 10,546
▲
Submission Date
22-10-2025
Contract Date
18-04-2026
Completion Date
180 days
Participated Bidder List
3 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 95,974.8 | L1 | |||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics |
Work Detail
tender for general - haripad municipality owc electrification-general electrical work; 1 owc electrification 2 90.2.1.1:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).single control light point with 6a, plate ceiling rose - short point 3 90.2.1.4:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).single control ceiling fan point with 6 a, 3 plate ceiling rose & with socket size stepped electronic regulator. - short point 4 90.2.1.6:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).combined plug point with 6 a, 5 pin plug socket controlled by 6 a, switch in the same switch board as that of light points 5 90.2.1.7:supply and wiring points according to is 732-1989 using rigid pvc conduit of minimum size 20 mm with specials conforming to is 9537 part iii 1983 and with suitable size specials conforming to is 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm frlspvc insulated stranded single core copper conductor cable 650v grade, including providingswitch boardmain and continuous earthing with no.14 swg bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6a modular type sp switches and making good the surface of wall, colour washing etc. complete. all the terminations in the switch boards and dbs shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (rohs compliant modular accessories).independent plug - short point 6 90.3.18.1:supply, fabrication, conveyance and fixing the following sizes of b class gi pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with hg company fabricated clamps 7 90.3.20.3:supply & installation of light fittings on tw round block supply, conveyance installation testing and commissioning the light fittings of following types made of crca with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with pvc round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant iss and giving connections as required.1200 mm 1x20w led lamp with box type fixture 8 90.15.4.2:supply conveyance, installation, testing and commissioning of 36/40w led street light output greater than 105lumen/w 4000-6000 k with ip 66 protection led chip make cree/lumilled/nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 kv,and aluminium pressure die-cast powder coated housing,acrylic cover complete with thd less than 10%, power factor greater than 0.98, rohs compliant, duly wired up for use on 230 v ac supply. driver compartment should be seperatly accessible for maintenance (lm 79&80 certificates from nabl accredited third party lab to be produced mentioning chip manufacturer) 9 90.4.1:supply and installation of suitable size ms rod type fan clamp in the rcc slab as per is 732 as required. 10 90.4.5.4:supply, installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/watt), air delivery minimum 210(cubic meter/minute), copper winding suitable for 230v/240v single phase ac supply 11 1.27.2:supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.3 module (100mmx75mm) 12 1.24.3:supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 13 1.24.5:supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 14 2.20:supplying and fixing 30 amps, 415 volts, tpn industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 15 1.17.12:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 2.5 sq. mm 16 1.17.22:supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.4 x 4 sq. mm 17 90.12.7.39:supply, laying and clamping of 1 no. pvc insulated and pvc sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp 18 90.12.7.40:supply, laying and clamping of 1 no. pvc insulated and pvc sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 19 90.16.1.3:supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 swg) 20 90.16.1.4:supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 swg) 21 90.6.10.1:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 22 90.6.10.2:supply and fixing of following sizes of light gauge pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm 23 90.16.5.3:supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 swg) 24 90.16.5.4:supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 swg) 25 9.1.32:supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.4 x 10 sq. mm (25mm) 26 9.1.33:supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required.4 x 16 sq. mm (28mm) 27 90.11.1.18:supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of mcb db including copper /brass bus bar, neutral link, earth bus and din rail suitable for fixing mcb/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover tpn vertical db with provision for fixing mccb as incomer and sp/ tp mcb as outgoing (ip 42/43) 28 90.14.10.4:supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to is 13947 suitable for 440 v, 50 hz, ac supply in the existing panel assembly as required.16 a-100a, 25/35 ka (ics=100%icu), 4 pole, current limiting type mccb having thermal setting range of 80 - 100% with thermal magnetic release having adjustable ol 29 2.10.1:supplying and fixing 5a to 32 a rating, 240/415 volts, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole 30 2.10.4:supplying and fixing 5a to 32 a rating, 240/415 volts, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. triple pole 31 2.13.1:supplying and fixing following rating, four pole, 415 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.40 amps 32 od5568/2025-2026:earthing with 40 mm dia. medium class gi earth pipe 2.5 mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm gi reducer at top, test joint using 2 nos ,25x3 mm gi strip minimum size 25cm suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 cm dia .around the earth electrode) 33 od5570/2025-2026:supply & providing fire buckets with stand in position as required 34 od5571/2025-2026:supply & providing 5 kg / nearest size dry chemical powder type fire extinguisher with hose & clamps fixing it to wall as required 35 od5572/2025-2026:supply & providing 2.5mm thick elastomeric fire retardent insulating mat as per is 15652/2006 to with stand 11kv dielectric strength 36 od5573/2025-2026:supply and providing first aid kit 37 90.1.1.3:supply and laying medium gauge pvc conduit of the following sizes conforming to is 9537/1983 part iii in roof slab, jointing the pipes with pvc solvent cement,tying & fixing the conduit firmly with the re-inforcement etc. as required.32 mm 38 od150332/2025-2026:supply and fixing of 3 phase meter box of dimension of 500x300x230 ( lxbxh) ( sintex 5030 or equivalent ) with connections, testing and commissioning etc. as required 39 od150341/2025-2026:supply and fixing of 63a hrc fuse link with hrc fuse base of approved make with connections, testing and commissioning etc. are required 40 od150352/2025-2026:supply and fixing of 63a 2 way nuetral link mounted on dmc / smc sheet with connections, testing and commissioning etc. are required
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results