View Bid Results For Weather Stations Tenders

We found 1123 Bid Results related to weather stations tenders. You can find Contractor details who won weather stations tenders along with contract details in Bid awards announcements section.

Filters
Stage
903
121
99
Tender Publishing Platform
406
717
State / UT
37
120
113
73
73
66
61
58
55
50
48
44
41
41
39
38
35
20
17
17
16
15
12
11
9
9
7
7
6
5
4
4
3
2
1
1
1
1
Contract Value
263
323
375
162
Publish Date
3
0
0
0
0
Sector
30
334
138
96
72
66
46
39
39
39
35
31
29
25
20
17
16
14
12
12
10
8
6
6
3
2
2
2
2
1
1
Ownership
6
505
363
131
113
7
4
Within keyword
Active filters:
Showing 1–23 of 1123 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 3.60 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Contract Date: Ref. Documents Contract Value : 8.04 Lakh
Government Departments No of Bidders 5
3.
Railways #11414448 AOC
Supply Of di- electrical safety shoes , supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as p er attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel to e. 1). size range : 5-11 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern ps v & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for worki ng environment with high voltage hazards power station operations substation (step-up/ step-down/ distrib ution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electr ical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved en iso 20345 : 2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistant outsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate c sa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock r esistance (esr) protection. 7). dielectricfootwear* astm f1117-03(2013) (min 20,000vac) 8). lining mater ial selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-pro of (electrically verified)reinforced rubber upper high visibility with orange and green contrast easy for clea ning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resis tant vulcanizedrubber outsole good abrasion resistant for extra durability heel energy absorption design to minimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 imp act andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards aci ds and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pa rs in a carton. various sizes of electrical safety shoe as per requirement (size 6-11 as per attached chart) [ warranty period: 12 months after the date of delivery ] ]
Contract Date: Jun 30, 2026 Contract Value : 31.95 Lakh
Government Departments No of Bidders 1
4.
Rural Development #11391666 AOC
Bids Are invited for Plane Table Complete Set As Per Isi Specification Consisting Of Board , Vernier Transit Theodolite As Per Isi Specification No 2988 1965 , Alidade Sight Vane Brass 24 , Clinometer Compass Semi Compass , Magnetic Trough Compass In Wooden Case 15 Cm , Quick Setting Dumpy Level Complete With Stand , Telescopic Alidade In Box With Standard Accessories , Prismatic Compass With Ring Divided In To Complete With Having Stand Ball , Telescopic Aluminum Stand For Prismatic Compass , Indian Pattern Clinometer Tangent Comp In Case , Abney Level With Slow Motion 6 , Box Sextant Pocket In Leather Case , Levelling Staff Aluminum Folding Type 6 Meter , Floating Globe Dia 16 Cms With Led Light Arc Base Self Revolving Leviating , Celestial Star Globe With Earth Inside Basic Dia 30Cms , 3D Globe 2 In 1 Globe Light Off Physical World Light , 3D Raised Relief Maps 75 100 Cms , Liquid Prismatic Compass Ms001 Liquid Prismatic Compass Mk Ia Guaranteed , Weather Station Fully Assembled And Well Equipped Weather Kit , Wind Speed Measurement Range , Multifunction Digital Altimeter Altimeter Barometer Compass Thermometer , Solar System Automatic Revolving With Cd Ge020 Cyber Sky Cd Rom Program , Astronomical Reflector Telescope 76Mm Objective Lens Dia 675 Telescope , 3D Self Framed Very Superior Quality Fibre Glass Models Rock Cycle Model , 3D Self Framed Very Superior Quality Fibre Glass Models Ocean Feature , Anerod Barometer , Sprit Level , Pantograph 60Cm In Box , Weather Report Map Polyart Plastic Geographical Astronomical Charts Total Quantity : 201
Contract Date: Ref. Documents Contract Value : 89.98 Lakh
Government Departments No of Bidders 4
7.
Youth Affairs and Sports and Culture #11323145 Technical Bid
Tender For Purchase Of Biomechanical Equipments , Nord Board , It Should Be Portable And Should Have 2 Load Cell Sensors Per Unit With Easy To Attach Hooks Pivoting 360 Degrees Joint Improving Sensor Accuracy It Should Have Knee Position Indicator For Replication Of Test Position In Each Time. Should Have Sample Rate Per Sensor: Upto 400Hz, Capacity Per Sensor: 100 Kg/980-1000N Safe Over Load Per Sensor: 150Kg/1500N, Max Over Load Per Sensor: 200Kg/ 2000N, Resolution: 1N And Sensitivity: 22.0+/-Mv/V. Should Have Rechargeable Battery & Battery Life Should Be100 Active Hours Approx. Should Have Working Temperature Range 5-40®C. (All Weather Proof) Latest Upgradable Software Should Have Both Wired & Wireless Connectivity Connectivity Through Usb (Wired) Bluetooth Low Energy (Ble) For Ipad & Iphone I.E. (Wireless Connectivity) Should Provide 4 Years Warranty On Hardware, Should Be Provided With Latest Upgradable Software And Free Software Updates. Should Have Software Available In Mobile & Laptop (Desktop) Application With Cloud Analytics Platform Applications. Should Have Ability To Collect Data Both Local I.E. Laptop And On Ios Devices. Local Software:- For Data Collection & Data Analysis Locally. Cloud Software:- For Athlete Data Management And Analysis. Local (Desktop /Laptop) Software Should Be Compatible With Windows 10 Desktop Application Ios 13 Or Later Application (Ipad & Iphone). Should Have Ability To Collect Data Of Over 10000 Athletes Or More To Choose With Simple Name Search / Grouping Them. Cloud Analytics Platform For Analysis. Software (Application) Must Give Real Time Feedback Of Testing. License Must Be Valid For 4Years. Cloud Software: - Should Automatically Sync All Data Collected On Local Mobile And Laptop Application When Connected To Internet. O Should Have A Dashboard To See Overview Of Organizations Athletes Data And Different Tiles (Data Indicators) To See Athletes Within And Outside Threshold Zones. Report Section:- Should Have Port Section To Able To Compare Different Groups/Athletes On Longitudinal Data. Should Have Ability To Compare Same Athletes Data Over The Period. Athletes Profile:- Should Have Functionality To Enter Anthropometry (I.E. Upper Body & Lower Body Measurement). Athletes Profile Should Be Auto Sync To Local Application And Flexibility To Move Across Different Groups Or Teams With In Organization And Functionality To Pick Any Athlete From Large Pool (1000 Or More Athlete). • Should Be Able To Setup Different Access To Different People I.E. To Physiotherapist, Sports Scientist And S&C Trainer Within The Organization To Secure Data Access. Api Integration:- Should Have Open-Source Api Code For Integration Into Athlete Management System To Integrate In Ams System. Should Have Software License Valid For 4Years. Wi-Fi Tablet 64Gb, Space Grey-1Year Warranty (As Provided By Oem) - Service By Customer Service Of Oem Only.Hsn:8471. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Electromyography (Open) , The System Should Be Supplied With Minimum 16 High Speed Wireless Emg Channel With Built In Imu Sensor. Should Have Analog+ Digital Base Station • Should Have Analogy Output Option To Facilitate Integration With Third Party Hardware And Software Sensor Should Have Fixed Inter Sensor Delay Of 0.5 Milliseconds Or Less Sensors Should Have Fixed Spacing Between Electrodes Preferably Less Than 15 Mm To Avoid Motion Artifacts And Cross-Talk Sensor Contacts Should Be Made Up Of A Metal For Better Contact And Better-Quality Signal Should Be Supplied With A Charging/Transmitting Station That Communicates With Sensors To Get Information On Their Charging, Recording And Signal Strength Sensors, Sensor Skin Interface, Cable, Power Adapter And Accessories Sensors Facilitate Emg And Imu Measurements Emg Data Analysis Software For Stand-Alone Usage With Live Recording Of At Least 32 Channels And Analysis For Both Online And Offline Modes. Trigger Module Package Analog Adapter With Cable For Dynamometer Integration. • Should Have Option For Real Time Data Streaming To Computational Softwares Such As Mat Lab. Mobile Emg Suite For Outdoor Applications Technical Support For The Lifetime Or At Least For A Period Of 05 Years. The System Should Be Supplied With Sensor Docking Unit And Charging System The System Should Be Supplied With Double Sided Adhesive Stickers (At Least 5000) And Double-Sided Adhesive Tape Rolls (At Least 20). The System Should Be Supplied With At Least 2000 Hz Of Sampling Rate Or More Per Sensor. The System Should Have A Baseline Noise < 1 ?V Or Better. The Emg System Should Have +20,000 ? Vemg Input Range Or Better. The System Should Have Software Controlled Digital Filtering, The System Should Have Shielded Cables For Minimal Artifact. The Software Should Allow Video Recording During Emg Data Recording Should Have At Least 8 Hours Of Battery Backup • Should Have Wireless Working Range Of At Least 40M Or More To Capture Data During Various Sport Specific Movements, Should Be Configurable To 32 Channels In Future. The Emg System Should Be Integrated With 3D Motion Analysis, Force Plate, Isokinetic Dynamometer, Instrumented Treadmill, Imu, Eye Tracking, Video Analysis Etc. The Necessary Third-Party Hardware/ Software Should Be Supplied By The Seller For Integration Of Emg With Other Systems. Laptop I7 (Latest Generation) With 32Gb Ram Or More, 2Tb Ssd, At Least 15.6-Inch Screen And Laser Printer With Copy/Scan/Print To Generate And View Report And Additionally A 32-Inch Monitor For Dual Display. Usfda, Iso & Euiec Certificates Or Equivalent. Installation At The Institute And Training To The Users By Experts Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Timing Gates (Open) , It Should Be A Wireless Speed Gate With 12 Gates And Provision For Increasing Gates Up To 15 Gates/Splits Or More With Split Distance Fully Customizable To Perform Variety Of Testing (Can Have Splits At 1 Meter Or 10 Meters Or Customized Distance). It Should Be Photocell & Reflector System Only (Light Or Laser Based) Considering Flexibility It Offers To Use Variety Of Testing Protocols With Visual Cue (Light System Provide A Cue To The Athlete To Change Direction) I.E. Single Or Dual Feedback Functions For Athletes. It Should Have An Accuracy Of Minimum 1 Hundredth Of A Second (1/1000Th Of A Second) Or Beyond, With A System To Eliminate Errors Caused By Hands, Feet And Other Body Parts, Equipment (To Provide Most Accurate Data) Must Have Error Correction Processing (Ecp) Inside The Timing Unit. Wireless Range: - Should Be Able To Control Gates Wirelessly With A Range Up To 180-200 Meters. It Should Have Functionalities To Provide 6 Options When Using Different Accessories A. Auto Beam Break B. In-Beam C. Reactive D. Start Pad E. Vibration (Reaction Time Measures) F. Rfid Various Accessories Should Be Integrated With Timing Gates Thus Providing Various Testing Possibilities Of Athletes. It Should Integrate With A Jump Mat (Accessories) For Plyometric Training And Explosive Power Measurement With Multiple Jump Testing Option On Jump Mats. Tests & Drills To Be Measured System Must Be Able To Measure- I. Linear (Straight Line Sprints), Shuttles With Customized Split Distance. Ii. Yoyo, Beep Tests (With Custom Customized Time Interval For Endurance Testing) Iii. Planned, Unplanned Change Of Direction For Agility Testing. Iv. Multiple Reactive Movements. V. Reaction Time Measure For Starting Blocks Any Customized Tests/ Drill With All 6 Or More Gates And No Restrictions On Number Of Customized Drills To Provide More Flexibility In Testing. • Mobile/Tablet Applications & Web Application: I. System Should Be Controlled By And Operated By Tablet/Laptop/Smartphone (Mobile Applications: -Should Have Both Ios & Android Mandatory Considering Large Android Phone User Base In India Along With Ios Application) And Ii. Must Have A Cloud Web Application Platform For Tracking Performance Variables Of 1000 Or More Athletes At One Go For Various Testing. Utility Of Mobile Applications: - I. Flexibility To Perform Test: -Mobile/Tablet Applications Should Have Functionality To - A. Pick Any Athlete From Large Pool (1000 Or More Athlete) B. Pick Any Drill Or Test To Be Conducted And Ability To Customize A Test With All 4 Or More Gates. C. To Visually Display Gates On Mobile Screen To Understand How To Perform A Test/Drill. Application To Automatically Detect Setup Of Gates. Ii. It Should Provide Real Time Data Of Performance, Reaction Time, Speed, And Agility. Iii.Single Or Multiple User With Authorized Access Control- Only Authorized Single Or Multiple Users Admins Should Have Access To Operate Application For Data Security And Data Access. Should Automatically Send Data To The Cloud Application Once Connected To Internet. Software License To Be Valid For 3 Years. Utility Of Web Application: - Functionality Of Web Application: - I. Automatically Populate Data Collected By Mobile Applications. Ii. Should Be Able To Compare Single Athlete Data Historically From Different Trials Or Compare Various Athletes For A Test Or A Drill Over Any Time Period. Iii. Should Be Able To Manage Athletes (By Creating Sports Specific Teams) Iv. Should Be Able To Download Data In Pdf, Excel And Ability To Customize These Reports V. Software License To Be Valid For 3 Years. Integration With 3Rd Party Ams System: -Software Should Have Functionality To Integrate Ams In Near Future Automatically, A Software Must Have Api Available For Seam Less Integration Of All/ Selected Data Of Speed Gates Automatically With Number Of World Leading Ams Systems And This Must Be Automated With Few Clicks Only. Rechargeable Battery Based Systems Should Have At Least 8 Hours Backup Or More. The System Should Be Robust Enough To Be Used In Various Weather Conditions. Should Have Height Adjustable Tripod Stands To Accommodate Various Sports Activities And Test Protocols. Should Provide One (1) Ipad Of Desired Specification To Run The Application (With Minimum 1 Year Warranty) Warranty For 2 Years. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. , Kinematic Analysis System (Open) , . Marker-Based And Markerless (Ai Based) Biomechanical System For Two-Dimensional (2D) Analysis Of Gait Analysis Including Walking And Running Activities, Posture And Other Sports Activities. 2. Biomechanical Motion Analysis Software (Pre-Installed In Computer) Within Built Modules For Standing & Sitting Posture Analysis, Walking Gait Analysis & Running Gait Analysis, Compatible With A Suitable Operating System. 3. It Should Allow Measurement Of Joint Angles & Other Data From Sports Specific Activities Like Jump, Squat, Golf, Tennis Etc. 4. It Should Also Have Features For Marker-Less Assessment Of Functional Activities Like Squats And Other Range Of Motions Of The Body During Various Activities. 5. It Should Be Able To Analyze The Anterior, Posterior, Left & Right Lateral Views Of The Subject And Provide The Following Parameters: (A) Walking Gait Analysis: Rear Foot Eversion/Inversion, Lateral Pelvic Drop, Knee Flexion/Extension, Hip Flexion / Extension, Ankle Plantar /Dorsiflexion, Knee Ab /Adduction, Stance Phase % - Swing Phase %, Step Length, Stride Length, Gait Velocity Etc. Data To Be Measured For Both Left And Right Extremities (B) Running Gait Analysis: Rear-Foot Eversion/Inversion, Lateral Pelvic Drop, Trunk Side Bending, Crossover Gait, Knee Flexion, Leg Inclination Angle, Knee Toe-Alignment, Hip Extension, Ankle Plantar Flexion, Net Vertical Oscillation Of Center Of Mass, Knee Ab /Adduction, Ground Contact Time Etc.. Data To Be Measured For Both Left And Right Extremities. (C) Posture Analysis: Major Postural Deviations Like Rear-Foot Eversion /Inversion, Forward Head Posture, Shoulder Protraction, Genu Recurvate, Lateral Head Tilt, Shoulder Level, Lateral Pelvic Drop, Lateral Trunk Sway, Q Angle (D) Sitting Posture Angle: Viewing Angle, Viewing Distance, Forward Head Angle, Elbow Flexion/Extension, Trunk Flexion/Extension, Knee Flexion/Extension, Hip Knee Alignment (E) Bike Fitting: Major Parameters Like Ankle Plantar Flexion /Dorsiflexion, Knee Flexion/ Extension, Hip Flexion, Hip Vertical Travel, Back Angle, Elbow Angle, Armpit Angle, Kops, Knee Tracking. (F) Squat Analysis: Major Parameters Like Descent: Ascent Ratio, Squat Stance Width, Heel Rise Detection, Head Tilt, Shoulder Tilt, Lateral Trunk Tilt, Pelvic Tilt, Frontal Knee Alignment, Knee-Toe Alignment, Trunk Inclination (Sagittal Plane), Tibia Inclination (Sagittal Plane), Knee Flexion (Depth Of Squat). 6. It Should Be Able To Generate Organized Reports With Following Features: (A) Data Represented In Tabular & Photographic Form (B) In Built Reference Ranges For Every Parameter Measured. (C) All Data Lying Outside Reference Ranges To Be Highlighted In Bold (D) Automatic Documentation Of All Observations And Abnormal Biomechanics In Form Of Notes (With Choice Of Hindi Or English Language If Needed). (E) Automatic Summary Of All Reports Should Be Generated. 7. It Should Have An Option To Export All Data To Excel Sheets 8. It Should Have An Inbuilt Comparison Feature That Generates Post Comparison Reports To Monitor Changes In Patients Posture And Gait. 9. It Should Have An In-Built Data Base Feature For Storing Analysis Data. 10. Software Should Use Ai (Artificial Intelligence) Models To Provide Markerless Analysis. 11. Software Should Also Use Ai (Artificial Intelligence) Models To Aid In Marker Digitization In Case Of Marker Based Analysis. 12. Motion Capture Cameras Supporting Video Capture In Outdoor Conditions (Running Track) As Well As Indoor Conditions (Floor, Walkway & Treadmill). Camera Specifications: (A) Wired Cameras-04 In Numbers With Capture Rate Up To 60 Fps. (B) Wirelesscameras-02 In Numbers With Capture Rate Up To 240 Fps. 12. The System Should Have Data Transfer Cables And Connector Cables For Camera Along With Tripods For Mounting Of Cameras. 13. Marker Set (With Marker Placement Guide) For Standing Posture, Walking Gait Analysis, Running Gait Analysis And Bike Fitting With Reusable Markers Or Disposable Markers (Adequate In Number For Conducting At Least 100 Tests Each) 14. Compression Clothing For Lower Body & Upper Body Should Be Provided. 15. Quality Clearance For Cameras: Usfcc/ Euce/ Isobis (Either Of The Certifications). 16. Should Be Safe And Non-Invasive, Easy To Use. 17. Carry Case/Bag For Storing And Carrying All Hardware Equipment To Be Provided. 18. In Person Training, Virtual Assistance & Technical Support For System Operation. 19. The Biomechanical Analysis Software Should Have License Validity Along With All Updates And Bug Fixes For A Minimum Period Of 10 Years. 20. The System Should Come With A Hardware Warranty Of 3 Years. 21. Computer Specifications: Intel 5Th Generation Processor Or Better, 8 Gb Ram, Windows 10/11, At Least 2 Usb Ports. , Foot Pressure Analysis System (Open) , 1. The Number Of Sensors Should Be Between 2900 To 4000. 2. The Active Sensor Area Should Be At Least 375 X 375 Mm. 3. The System Should Be Able To Perform Static (Standing) & Dynamic (Walking) Assessment And Provide Data Of Foot Pressure Distribution During These Activities. 4. It Should Also Have Capability To Perform Sway (Balance) Assessments During Eyes Open And Closed Conditions. 5. System Should Be Able To Generate Automated Remarks For Symmetries Of Pressure Distribution. 6. System Should Be Able To Identify Change In Pressures With & Without Footwear /In Soles. 7. Option Of Comparing Patients Data Over Time Should Be Provided. 8. Option Of Exporting Report Data In Excel Format Should Be Available. 9. Facility To Email Report With Patient Information Should Be Provided. 10. System Should Have Wired Operation. 11. System Should Work Without The Internet. 12. Should Have Operating Temperature Range Between 5° C To 50°C 13. Frequency Range Should Be At Least 100 Hz 14. Pressure Range Should Be Between 1 To 150 Psi 15. Sensor Resolution Should Be Equal To Or More Than 2 Per Cm^2 16. Sensor Technology Should Be Piezo Resistive 17. Should Be Supplied With A Padded Carry Bag. 18. Should Be Supplied With 2 Additional Dummy Platforms 19. System Should Not Need A Separate Electrical Supply And Should Draw Power From The Computer. 20. The Complete System Should Have 3-Year Hardware Warranty Period Along With Software Updates And Tech Support. Training For Installation And Demonstration Shall Be Provided At Olympian Balbir Singh Senior International Hockey Stadium, Sector- 63, Mohali, Punjab. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 97,800
Statutory Bodies & Commissions/Committees No of Bidders 7
9.
Power #11314307 Price Bid
Tender for Strenthning Of 11 Kv Line B.Plan 2026-27 Scheme At Various Site Of Edd-Hapur, Under Edc Hapur (17 No. Work) (Dpr N0. 44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60) , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 11.0M Long , Plain Cement Concrete Pole 8.5M Long , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , 11Kv Xlpe Cable 3X120 Sqmm , 11Kv Xlpe Cable 3X185 Sqmm , 11Kv Termination Kit 3X185 Sqmm O/D , 11Kv Termination Kit 3X120 Sqmm I/D , 11Kv Termination Kit 3X120 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv Polymeric Disc Insulator With Fitting , 11Kv V-Type Cross Arm , Earthing Rod , G.I. Wire 6Swg , G.I. Wire 8Swg , Stay Set , Stay Wire 7/10 Swg. , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , 11Kv Termination Kit 3X120 Sqmm I/D , 11Kv Termination Kit 3X120 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv Polymeric Disc Insulator With Fitting , 11Kv V-Type Cross Arm , Erection And Fixing Of Pole Structure For 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Grouting Of St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Laying, Stringing And Final Sagging Of Acsr Weasel/Rabbit/Dog Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×120Sq.Mm Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Hdd Method For Laying Of Underground Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185Sq.Mm In Hdpi Pipe By Safly Pulling, Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Gi Pipe 6 Inch Dia Along With Suitable Clamps, Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , M.S. Channel 100X50x5mm , M.S. Angle 65X65x6mm , Providing And Fixing Guarding Angle Size 50*50*5 And Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Gi Wire Will Be Provided By Department). , Providing And Installation Of Maintenance-Free, Multifaceted, Corrosion-Resistance Free Gi Pipe Earthing Upto Water Level Pipe Dia 2 Inch 80Feet. Providing And Fixing Of Gi Earth Strip Size 50Mm*6Mm For Connection (The Strip To Be Properly Welded To The Earthing Electrode And Neutral Support), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Excavation, Installation, Welding, Connection, Testing, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Construction Of 11 Kv Line B.Plan 2026-27 Scheme At Various Site Of Edd-Hapur, Under Edc Hapur (01 No. Work) (Dpr N0. 69) , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 8.5M Long , 11Kv Xlpe Cable 3X185 Sqmm , 11Kv Termination Kit 3X185 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv V-Type Cross Arm , Earthing Complete , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , 11Kv Termination Kit 3X185 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv V-Type Cross Arm , Erection And Fixing Of Pole Structure For Plain Cement Concrete Pole 8.5 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 8.5 Mtr Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Digging Of Trech As Per Respo Drawings/Standard Norms For 11 Kv Ht Xlpe Cable Of Size 3×185Sq.Mm Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Including Proper Installation And Commissioning At Site.Including Machinery, Drilling/Excavation, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues Measurement Shall Be Made On Actual Length Of Trech At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. And Completing The Work As Per Directions Of Engineer-In-Charge , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185Sq.Mm (Double Ckt) Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Gi Pipe 6 Inch Dia Along With Suitable Clamps, Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing And Fixing Of Gi Pipe 6 Inch Dia Along With Suitable Clamps, Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-I Hapur, Under Edc Hapur (5 No. Work) (Dpr N0. 102, 103, 104, 105 & 107 ) , Safe Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 11.0M Long , 11/0.440 Kv 250 Kva Dt , Acsr Weasel Conductor , Lt Ab Cable 3X120+1X95+1X16 Sqmm , Lt Pvc Alu. 1X400 Sqmm , Lt Pvc Alu. 1X240 Sqmm , Lt Pvc Alu. 3.5X400 Sqmm , 11Kv Polymeric Pin Insulator With Pin , 11Kv Disc Insulator T&C Type 45 Kn With Fitting , Earthing Complete , Stay Rod , 11 Fuse Set , Stay Wire 7/10 Swg. , Erection And Fixing Of Double Pole Structure For Plain Cement Concrete Pole 11 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 11 Mtr Supports In cement concrete 1:4:8 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:4:8 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Double Pole Clamps Including, Holding Clamps, Top Channel Clamps, Dropper Channel Clamps Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Danger Board Of Approved Design And Size, Made Of Suitable Weatherproof Material With Required Painting And Lettering, Including Fixing On Pole/Structure With Nuts, Bolts, Clamps And All Necessary Labour, Tools & Plants For Complete And Satisfactory Execution Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing & Fixing Of High Quality 3 Phase 4 Wire 440V, 400A, ≥ 35Ka, With Overload Short Ckt And Earth Falt Protection, Outdoor Type, Weather Proof Lt Mcb With Box With Locking Arrangement For 11/0.440Kv, 250 Kva Dt With Long Barrel Al. Lugs Off Size. Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of High Quality Long Barrel Al. Lugs Off Size. Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of High Quality Henley Type Tailless Unit Protection Cubical Panel 500A, 650V For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials Such As Long Barrel Lugs, Glands, Nuts & Bolts Etc.) Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv D.O. Fuse Set Protection Unit For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Lugs, Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 11/0.440 Kva 250 Dt With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Erection And Laying Of Lt Pvc Inculding Proper Connection With Long Barrel Lug, Proper 3 Nos Crimping On Each Lug, Lt Fuse Set/Smc Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Lt Pvc Alu. 1X400 Sqmm , Lt Pvc Alu. 1X240 Sqmm , Lt Pvc Alu. 3.5X400 Sqmm , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Erection Of Chemical Earthing For Neutral Of Dt With Gi Strip 50X6mm Including Excavation Of Pit And Using Necessary Chemical And Electrode To Obtain Results ≤ 1 Ohm, 3M Apart From Support, Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Strip & Earthing Lugs, Nut And Bolts As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Construction Of Tif Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mtr.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Provinding & Fixing Of Safety Fencing (Ms) For 11/0.4 Kv, 250Kva Dt, With Supply Of Material Required For Ms Fencing Upto Dt Upper Level By Constructing 1 Feet Masnary Wall With Bricks & 4X8 Feet Frames Bolted And Welded Alongwith, The construction Of Frames With 75X75x6 Mm Corrosion Free Ms Angle, 8 Swg M.S. Gi Wire Mess Corrosion Free Made Of Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle To Be Fitted On Vertical Posts. And Dual Door Gate To Facilitate Entry And Exit With Locking Arrangements. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Gi Angle . Such Post Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Metalic Materilas Should Be Galvanized & Corrosion Free) , Providing And Fixing Of All Types Of Clamps Suitable For Electrical Line/Equipment Works, Including Supply Of Approved Quality Clamps, Nuts, Bolts, Washers, Fabrication, Fitting, Tightening, And All Necessary Labour, Tools & Plants Required For Complete And Satisfactory Execution Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Jul 01, 2026 Contract Value : 44.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Jun 15, 2026 Contract Value : 21.16 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
12.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
14.
Railways #11276863 AOC
Supply Of di- electrical safety shoes , supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as p er attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel to e. 1). size range : 6-9 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for workin g environment with high voltage hazards power station operations substation (step-up/ step-down/ distribu tion) operations electrical hazards with wet condition/ water exposure high current leakage hazards electrical installations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved ? en iso 20345 : 2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistant outsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl s ulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electri c shock resistance (esr) protection. 7). dielectric footwear* astm f1117-03(2013) (min 20,000vac) 8). li ning material selected polyester grade lining comes with extra comfort and durability 9). upper constructio n leak-proof (electrically verified) reinforced rubber upper high visibility with orange and green contrast e asy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environme nt slip resistant vulcanized rubber outsole good abrasion resistant for extra durability heel energy absorpti on design to minimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets c sa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistan t towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable p olybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 5-12) [ warran ty period: 30 months after the date of delivery ] ]
Contract Date: Jun 12, 2026 Contract Value : 4.01 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 47.58 Lakh
Boards / Undertakings / PSU No of Bidders 12
Arunachal Pradesh View Result →
17.
Petroleum and Natural Gas #11265616 AOC
Bids Are invited for Pipeline Laying Installation By Open Trench Method - Laying Of 100 Mm X 6 Point 4 Mm 4 Inch Api 5L Gr X 52 External 3Lpe Coated By Open Cut Method , Pipeline Laying Installation By Hdd Without Casing - Laying Of 100 Mm X 6 Point 4 Mm 4 Inch Api 5L Gr X 52 External 3Lpe Coated By Hdd Method , Long Radius Bends 300 Class 90 Degree - Supply Of Long Radius Bends R 3D For 4 Inch Dia Pipe X 52 Thickness 6 Point 4 Mm 4 Inch Nb Material Api 5L X 52 Astm A 860 Wphy 52 Minimum Thickness 6 Point 4 Mm , Purging And Inertisation Of 4 Inch Pipeline Including Supply Of Nitrogen - Purging And Inertisation Of 4 Inch Pipeline Section Up To 2 Barg , Hot Tapping Works - 12 Inch X 4 Inch With Split Tee 300 Class , Tcp Work - Sacrificial Anodes Pre Packed Magnesium Anodes , Supply Laying Termination Glanding And Ferruling Tcp Cables - 1 Core X 6 Mm2 Anode Tail Cable Unarmored , Supply Laying Termination Glanding And Ferruling Of Tcp Cables - 1 Core X 6 Mm2 Potential Measurement Tlp To Pipeline Armored , Supply Laying Termination Glanding And Ferruling Tcp Cable - 1 Core X 10 Mm2 Current Measurement Cable And Pipeline To Test Station Armored , Supply Laying Termination And Glanding And Ferruling Tcp Cable - 1 Core X 25 Mm2 Bonding Earthing Surge Diverter Ht Line Etc , Tlp Test Stations - New Test Stations Normal Size All Weather Proof With Ip 55 , Pipeline Laying Installation Of Above Ground Pipeline , Pipeline Laying Installation Of Above Ground Pipelines , Pipeline Laying And Installation Of Above Ground Pipeline , Supply Of Assorted Pipe Fittings And Flanges , Supply Of Assorted Pipe Fittings And Flange , Supply Of Assorted Pipe Fittings Flanges , Flanges - Supply Weld Neck B 16 Point 5 A105 Charpy 125 Aarh Rf , Supply And Installation Of 90 Degree Elbow R 1 Point 5D Rating 300 Class - 4 Inch Nb Material Api 5L X 52 Astm A 860 Wphy 52 Minimum Thickness 6 Point 4 Mm , Supply And Installations Of 90 Degree Elbow R 1 Point 5D Rating 300 Class , Sockolet A105 Sw , Uneq
Contract Date: Ref. Documents Contract Value : 33.52 Lakh
Boards / Undertakings / PSU No of Bidders 4
18.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 4.95 Lakh
Government Departments No of Bidders 1
Contract Date: Jun 05, 2026 Contract Value : 39.86 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
21.
Communications and Information Technology  #11216366 Technical Bid
Tender For Maintenance And Repair To Amravati Hpo Under Amravati Division; 1. Acrylic Emulsion Paint Asian (Royale), ICI (Velvet), Berger (Luxol Silk), Nerolac (Allscapes) 2. Premium Acrylic Smooth Exterior Paint Apex Ultima of Asian paints, Weather Coat All Guard of Berger Paint. 3. Aluminium Composite Panel Alpolic, Aluco Bond, Reynobond, Euro bond, Al-stone, Aludecor. 4. Aluminium Extrusions Hindalco, Indalco, Jindal. 5. Aluminum Sections Hindalco, Indalco, Jindal. 6. Board & Plywood Duro, Green, Century. 7. Ceramic/Rectified Tiles Premium double charge tiles of :-Kajaria, RAK, HR Johnsons 8. CP fittings Hindware, Johnson, Marc, Cera 9. CPVC Pipes Astral,Flowguard, Ashirvad, finolex,supreme 10. Designer coloured cement concrete floor tiles for external used / Concrete paver blocks. Ultra, Nitco, or Equivalent (mandatory tests to be performed before execution). 11. Epoxy Primer & Paints Berger, Pidilite, SIKO, Asian. 12. Float Glass Modi Float, Saint Gobain, Tata. 13. Flush Doors (ISI Mark only) Green, Duro, Century or Equivalent (mandatory tests to be performed before execution). 14. Galvanized/Stainless Steel Anchor Fasteners Arrow, Hilti, Fischer, Hatticth 15. Gun Metal Gate Valve Zoloto, Leader, SAINT 16. Gypsum Board False Ceiling Boral Gypsum, Gypsum India Limited, USG, St. Gobain(Gyproc) 17. Hardner Hard crete of Snowcem India, MC Deritop F.H. 18. Hydraulic Door Closer Hardwyn, Godrej, Dorma, Doorset 19. Hydraulic Floor spring Hardwyn, Godrej, Dorma, Doorset 20. Laminate Greenlam, Decolam, Century, Formica. 21. Melamine Polish Melamine Gold of Asian Paint, Wudfin of pidilite, Timbertone of ICI Dulux. 22. M. S. Pipe Electro Steel, Apollo (ISI), Jindal, Tata 23. Marine Plywood / BWP Ply Century, Green, Duro 24. Oil Bound Distemper Asian (Tractor), ICI (Maxi lite), Berger(Bison), Nerolac (NAD) 25. Sanitary fittings Hindware, Cera, Jaquar 26. Plastic Connection Pipe Jaquar, Kamal Delux. 27. Ply Wood Duroply, Green ply, Century ply 28. Pre-coated GI sheet for roofing Jindal Saw, Tata Blue Scope. 29. Polymer Modified Cementitious grout Bal-Endura, Pidilite, Ceco. 30. Pre-laminated Particle Board IS : 12823 (Gr-I, Type-II) Action TESA, Kitlam, Archid Ply, Asis, Green Lam 31. Primer Asian, ICI DuLux, Nerolac 32. PVC Rain Water Pipe & Fitting IS:13592 Type A Finolax, Supreme, Plasto. 33. PVC Shutter Rajshri, Sintex, Akal America. 34. PVC Tank (ISI Marked) Sintex, Star, Lotus, Plasto, Supreme. 35. R. C. C. Pipes (NP-2) ISI Make 36. Solid Plastic Seat Cover for EWC EWC standard seat cover white of Perryware/Hindware/ Neycer, Cera. 37. Stainless Steel Jindal Stainless Steel, Salem Steel 38. Stainless steel Sink with or without Draining board. Nirali, Hindware 39. Structural Silicon Sealant Dow Corning, Wacker, GE. 40. Structural steel section TATA, SAIL, RINL, Jindal. 41. Synthetic Enamel Paints ICI(Dulux),Asian (Apcolite),Berger (Luxol),Nerolac (NST) 42. Textured Exterior wall paint Snowcem, ICI (dulux), Asian. 43. Towel Ring/Towel Rod/Towel Rack. Marc, Jaquar, 44. Tubular Section Windows M/S classic Engineers & Fabricator, Raipur, M/s JK Enterprises, Jaipur. 45. TMT Bars As per criteria laid down in Para 4.3 of Part-B 46. Vitrified Tiles First quality full body tiles of Kajaria, RAK Ceramics, Johnson, NITCO, RESTILE 47. Waste Pipe Kamal with brass checknut,Viking 48. Water Proofing Compound (Liquid) Pidiproof Ltd., Sico, Impermo 49. Wire mesh Sterling, Trimurty welded mesh. 50. White Cement JK, Birla etc 51. Wall Putty JK, BIRLA, Asian 52. Work Stations/ Modular Furniture Godrej, Wipro 53. Stoneware pipe and Gully Trap Perfect or equivalent 54. PVC flushing System Johnson, Somany, Hindware, Jaquar 55. Tactile Tiles Johnson, Somany, Kajaria 56. Plastic Emulsion Paint Asian, ICI, Berger, Nerolac
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Maharashtra View Result →
22.
Defence #11213484 AOC
Tender For Repair And Maintenance Of Pumpsets, Submersible Pumpsets, Misc Works, Cleaning And Disnfecting Ug Sumps, Oh Reservoirs At 2Wing And 9Brd Afs Pune Under Ge (Af) Lohegaon.; 1 Taking out the submersible pump/Openwell Submersible Pump set forrepairsand lowering down after repairs the submersible pump set of any capacity& of any type from the bore well to a depth of not exc. 70 mtrs including scrapping of the existingpaint of submersible pump set and applying two coats of anti corrosive paint over a coat of primer complete after repair / replacement of spares and commisssioning all as directed by Engr-in-Charge.NOTE: COST OF REPAIR SHALL BE MEASURED AND PAID AGAINST RELEVANT ITEM 2 Repairs to submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weightof PVC insulated copper conductor incl renewal of thrust plate,CI bowl,pump shaft,impeller ,Bearing,strainer,bush cable gaurd etc. reassembling, testing and commissioningcomplete all as directed by Engr-in-Charge. 3 Repairs toNon clog ,Open well submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weightof PVC insulated copper conductor incl renewal of Mechanical seal, Bearing ,thrust plate,CI bowl,pump shaft,impeller ,strainer,bush cable gaurd etc. reassembling, testing and commissioningcomplete all as directed by Engr-in-Charge. 4 Renewal of column pipe 50 mm dia heavy duty ISI marked ,10 feet lengthboth ends machine threaded with longthread heavy duty socket complete all as directed by Engr-in-Charge. 5 Replacement of unserviceablePVC weather proof cable and replacementwithnewPVC weather proofcopper cable for size3 core2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge. 6 Replace of non return valve gun metal 50 mm bore complete all as directed by Engr-in-Charge. 7 Replace of non return valve gun metal 150 mm bore complete all as directed by Engr-in-Charge. 8 Taking outold unserviceable MCCB 400/360 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,400 Ampsall as directed. 9 Taking outold unserviceable MCCB 250 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,250 Ampsall as directed. 10 Taking outold unserviceable MCCB 200 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,200 Ampsall as directed. 11 Taking outold unserviceable MCCB 160 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,160 Amps. 12 Taking outold unserviceable MCCB 100 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,100 Amps. 13 Taking outold unserviceable MCCB 63 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,63 Amps. 14 Material and labour for reparing/maintenance of existing electrical panel boards of pump sets by replaing worn out spares as starter/single phase preventor/relay /contactors MCCBs / MCBs / switch gear / cable glands/ lugs pin type,U type etc, cleaning of panel board, tightening of cable connection to avoid sparking, insulating bus bars bracket portion of conductor and to ensuring proper function of the panel board all as directed by Eng-in-Charge.NOTE: ( I ) Cost of spares as starter /single phase preventor/voltmeter/Amp meter/ relay / contactor /MCCBs/ MCBs / Switch gear / cable gland etc shall be measuredand paid against relevant item.(ii) Cost of lugs (pin type / U Type) ,insulation taps shall be included in quoted rate.(iii) Cost of fixing of spares shall deemed to be included in quoted rate. 15 Renewals/replacingthe followingspares to the existing elecrical panels complete all as directed by Engr-in-Charge. 16 S& F Voltmeter/Ammeter ,3 phase for range 0-200A Class-I, suitable as per existing 17 S&F in replacement of old unserviceable contactor ofcapacity upto 45 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc, suitable for existing contactor 18 S&F in replacement of old unserviceable contactor ofcapacity upto 95 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc, suitable for existing contactor 19 S&F in replacement of old unserviceable contactor ofcapacity upto 110/120 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc, suitable for existing contatctor 20 Over load relay 3 phase 415 Volts with range 16 to 45 A suitable for existing 21 Over load 3 phase 415 Volts relay with range 45 to 88 A suitable for existing 22 S& F Single phase preventor including Timer,415 V suitable for 100 HP motor. 23 Dismantling the centrifugal Pump/monoblock pumpset with motor of capacity Upto 3HP including disconnecting suction and delivery, power supply cable etc and reassembling same after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete and replacing the same and testing all as specified and as directed by Engr in charge.NOTE: 1.In case of Centrifugal pump dismantling of pump and motor will be paid seperatly.2. In case of Monoblock pumpset pump/motor paid as one3. Spares such as bearing, bush, gland packing, coupling, capacitor will be measured & paid seperately 24 All as per item no 16 but for the capacity of 5 HP to 7.5 HP 25 All as per item no 16 but for the capacity of 10 HP to 15 HP 26 All as per item no 16 but for the capacity of 20 HP to 30 HP 27 All as per item no 16 but for the capacity of 40HP to 50HP. 28 All as per item no 16 but for the capacity of 60HP to 75 HP 29 All as per item no 16 but for the capacity of 90HP to 100HP 30 Supply only following worn out spares of Centrifugal/monoblock pump sets. 31 Bearing as per existing Size suitable for up to 3HP motor 32 Bearing as per existing Size suitable for 5HP to 7.5 HP motor 33 Bearing as per existing Size suitable for 10 HP to 12.5 HP motor 34 Bearing as per existing Size suitable for 20 HP to 30HP motor 35 Bearing as per existing Size suitable for 40HP to 50 HP motor 36 Bearing as per existing Size suitable for 60HP motor 37 Bearing as per existing Size suitable for 75 HP motor 38 Bearing as per existing Size suitable for 90 HP motor 39 Bearing as per existing Size suitable for 100 HP motor 40 Rubber bush/star rubber for coupling as per existing size for upto 30 HP motor 41 Rubber bush/star rubberfor coupling as per existing size forupto 50HP motor 42 Rubber bush/star rubber for coupling as per existing size forupto 75 HP motor 43 Rubber bush/star rubber for coupling as per existing size for upto90 HP motor 44 Rubber bush/star rubber for coupling as per existing size for upto 100 HP motor 45 Gland packingupto30 HP pump 46 Gland packing for 40 HP motor 47 Gland packing for 50 HP motor 48 Gland packing for 60 HP motor 49 Gland packing for 75 HP motor 50 Gland packing for 90 HP motor 51 Gland packing for 100 HP motor 52 Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 5HP,12.5HP,20HP 53 Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 30HP,40HP,50HP 54 Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 60HP,75HP,90HP,100HP 55 Overhauling/servicing of Suction sweeper assembly trolley mounted with mud pump motor head 11.5 mtr make; Kirloskar for swimming pool complete all as specified and directer by Engr-in-charge. Notes:- including spares require for making the assembly serviceable deemed to be included in subjected item. 56 M & L for Rewinding ofelectric motor 3 phase, 415 Volt capacity 1/2HP TO 3 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its ownposition, replacing the old nut,bolts and testing all as directed. 57 All as per item no. 28 but for the capacity of 5HP. 58 All as per item no. 28 but for the capacity of 10HP,12.5HP 59 All as per item no. 28 but for the capacity of 15HP,20HP. 60 All as per item no. 28 but for the capacity of 30HP. 61 All as per item no. 28 but for the capacity of 40HP 62 All as per item no. 28 but for the capacity of 50HP 63 All as per item no. 28 but for the capacity of 60HP. 64 All as per item no. 28 but for the capacity of 75HP. 65 All as per item no. 28 but for the capacity of 90HP. 66 All as per item no. 28 but for the capacity of 100HP. 67 Taking out unserviceable foot valve 80 mm dia from the UG sump and S & F new foot valve 80 mm dia ball typeincl rubbergasket, bolts, buts complete all as directed. 68 Taking out unserviceable foot valve 100 mm dia from the UG sump and S & F new foot valve 100mm dia ball typeincl rubbergasket, bolts, buts complete all as directed. 69 Taking out unserviceable foot valve 150 mm dia from the UG sump and S & F new foot valve 150mm dia ball typeincl rubbergasket, bolts, buts complete all as directed. 70 Supply and fix spares for pumps of DSM 150/45, DSM 100/36, DSM 125/45, DBHS 71 a) Impeller 1st , II nd Stage 72 b) Pump Shaft 73 c) Shaft sleave 74 d) Cartrige bearing DE/NDE 75 e) Through bush 76 f) Split gland coupling 77 g) Wear ring 78 h) Lantern Ring 79 h) Gland coupling 80 Supply and replacing Automatic DOL starter suitable up to5 HP submersible/ centrifugal pump set 81 Supply and replacing Automatic star Delta starter suitable 7.5 HP to 12.5 HP submersible/ centrifugal pump set 82 Replacement of nuts bolts to top & bottom cover of DSM pump 100 HP, 90 HP, 75 HP. 83 Supply & fixing in replacement LT cable 1100 volts grade PVC insulated multistranded copper conductor cable single core of size 35 sqmm. 84 M&L for cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumpsof capacity.(a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank .(c). Third strage is fresh water cleaning by high speed jet pump.(d). Fourth stage and first bacteria screening is decertification.(e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g)Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent. NOTE:-(i) COMPANY WILL SUBMIT LABORATORY TEST CERTIFICATE OF CHEMICAL USED BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY. 85 a)All as per Item no. 50 but for UG sump 100000 gallons capacity 86 b) All as per Item no. 50 but for UG sump10,000 gallons capacity 87 c)All as per Item no. 50 but for UG sump50000/30000 gallons capacity 88 d)All as per Item no. 50 but for O H Reservoir 300000 glns capacity 89 e)All as per Item no. 50 but for O H Reservoir 50000 glns capacity 90 f)All as per Item no. 50 but for O H Reservoir 150000 glns capacity 91 g)All as per Item no. 50 but for O H Reservoir 10000 glns capacity 92 h)All as per Item no. 50 but for O H Reservoir 25000 glns capacity 93 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity up to 10000 Glns complete all as specified and directed by Engr-in-charge 94 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity 10001 to 15000 Glns complete all as specified and directed by Engr-in-charge 95 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity 15001 to25000 Glns complete all as specified and directed by Engr-in-charge 96 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity 50000 Glns complete all as specified and directed by Engr-in-charge 97 S&F spare parts of chlorine dozers at various loaction as per directed by Engineer in charge 98 a) Pump head (ferrules 1/4 & duckbill included) 99 b) Pump Tube (pack of 5) 100 c) Injection cheack valve 3/8 101 d) 3/8 white suction/discharge tubing 102 e) Check valve duck bill only (pack of 5) 103 f) Connecting nut 3/8 104 g) Connecting nut 3/8 with adapter(pack of 5) 105 h) Ferrule 1/4 (pack of 24) 106 Supply and fix XLPE insulated, armoured heavy duty electric cable withn aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm,3.5 core as per direction of Engineer in charge 107 Supply and fix wall mounted metal enclosure consist of On load change over of capacity 250 Amps 415V, 4 pole to be installed as per the direction of Engineer in charge 108 Supply and fix wall mounted metal enclosure consist of On load change over of capacity 400 Amps 415V, 4 pole to be installed as per the direction of Engineer in charge 109 Supply only drinking water testing Kit having testing water parameter like PPM of chlorine,PH etc . 110 Supply only O tolidine reagent for testing of chlorine content in drinking water as per direction of engineer in charge. 111 Supply only swimming pool water clarifier as per direction of Engineer in charge 112 M & L for installation of sign board made of 3mm ACP sheet pasted on Recto Reflective Sign Board ncluding Frame working, SS Steel, fitting & Concreting work complete all as per direction and approval of Engineer in charge (Notes :- Matter/colour to be printed shall be provided by Deptt) 113 Material & Labour for painting of Pumps inlcuding motor, suction & Discharge Pipes of capacity upto 12.5 HP 114 Material & Labour for painting of Pumps inlcuding motor, suction & Discharge Pipes of capacity upto 50 HP 115 Material & Labour for painting of Pumps inlcuding motor, suction & Discharge Pipes of capacity upto 100 HP
Contract Date: Jan 09, 2026 Contract Value : 15.52 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Maharashtra View Result →
23.
Public Administrative Department #11199742 AOC
Carrying Out Civil Maintenance Work For The Phase 1,2,3,4 At Ravet Pumping Station.-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Excavation for foundation in earth, soils of all types, sand ,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed forthe foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5m To 3.0 m.) By Mechanical Means Providing general pest control services to the building to control the nuisance of cockroaches, lizards, pin bores and other insects etc. with 4 operations in a year and monthly check up. Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete. Removing grass, gazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc. complete. Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs anddrawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. Providing Gas or Electrical welding for structural steel section, plates as per detailed drawing. For less than 10 mm thick section. Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc .complete. Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing Second class fly ash brick masonry with conventional / I.S. type bricks cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Gound Floor Removing the tar or coba and disposing of the material as directed etc. complete. Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. Providing and Applying DuraClean- WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraGuard - as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturers specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of to 15 mm thick in C.M. 1:4 rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Providing flush grooved pointing with cement mortar 1:3 for brick work including scaffolding and curing etc. complete. Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. line and level including neat finishing scaffolding curing etc. complete. Providing and laying Polished Tandur Stone flooring 25mm to 30mm thick required width in plain/ diamond pattern on bed of 1:6 C.M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Providing sills of polished Kadappa stone 25mm to 30mm thick, on a bed of 1:4 cement mortar including cement float, filling joints with slurry, curing polishing and cleaning etc. complete. Providing and fixing heavy duty inter locking concrete Grey paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in requiredposition laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete Ground Floor Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. Providing and applying priming coat over new/old steel and other metal surfaces including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steel wool, scrappers and sand paper, scaffolding etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning preparing the plaster surface applying primer coat scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary Scrapping the old plastered internal surface with sand paper and coating the entire surface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. excluding the primer coat.) etc. complete. Lift 0.0 to 3.8 M Providing and applying plaster with plaster of paris in 6mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 mm x 40 mm weighing 0.39 Kilogram/m. at 60 cms c/c and fixed with ( 15 x 15 mm) flanges weighing 0.119 Kilogram/m suspended on 6 mm dia. mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 mm x 40 mm weighing 0.39 Kilogram/m etc. including all labour etc. complete. Providing and fixing false ceiling of 15mm thick as per drawings including powder coated G.I. wall angle of 20 mm x 20 mm x 0.60 mm size, G.I. grid runners of size 15 mm x 38 mm at 600 mm center to center both ways and suspended using G.I. 3 mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete. Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). Providing and fixing plain zinc sheeting of 0.80 mm thick (22 B.W.G.) over the ridge hip or valley to galvanized iron sheet roofing including all fastening and bolt galvanised iron screws and bolts, lead and bitumen washers etc. complete.(Weight of 6.8 Kilogram/sq.m.). Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Providing and fixing factory made panelled door shutter in single leaf 35 mm thick style and rail without ventilator with CCTW panels 12 mm thick including wrought iron hold fast and stainless steel fixtures with oil painting 3 coats etc. complete. Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One RunningMetre. Inter locking section 40 x 18 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass withall required screws and nuts etc, complete. With colour Anodising with box. etc
Contract Date: Jun 01, 2026 Contract Value : 44.74 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 62.87 Lakh
Government Departments No of Bidders 2
Arunachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.05 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Madhya Pradesh View Result →
26.
Power #11144553 Technical Bid
Tender for Supply Of Electrical Spares And Minor Stores/Hardware Items From The Original Equipment Manufacturer, Their Authorized Dealer/Local Representative Or Local Ssi Units Registered Firms/Suppliers Already In The Trade For The Year 2026-27 , Hardware Fitings And Accessories,Clamps And Connectors For Acsr /Aaac Conductor , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Ultimate Tensile Strength Of (H/W) 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type ) , Single Tension Hardware Fitting For Acsr Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg,Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550 Kg , Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc.. (Station Type) , Double Suspension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Suspension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators.,Uts Of Hardware =7000Kglikely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Line Type ) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided ( Station Type) , Double Tension Hardware Fitting For Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Of Hardware = 9000Kg. Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc ( Line Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Tension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg, Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Zebra Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Station Type) , Single Suspension Fitting For Acsr Twin Moose Conductor Conforming To Is 2486 (Part-I) Ammended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators.,Uts Of Hardware = 9000Kg Uts / Slip Strength Of Clamp = 95% Uts Of Conductor = 8550 Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc (Line Type) , Single Suspension Hardware Fitting For Aaac Panther Conductor 37/3.15Mm Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Hardware =7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Single Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 20Mm B&S 120Kn Disc Insulators., Uts Hardware = 9000Kg Uts/Slip Strength Of Clamp = 95% Of Uts Of Conductor = 8550Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Suspension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date) And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Double Tension Hardware Fitting For Aaac Panther Conductor Conforming To Is 2486 (Part-I) Amended Upto Date And The Specification Stipulated In Sec. Iii Of This Tender Document Having Tension Clamp Of Al Alloy Grade-A6(Is: 617-1975), Ferrous Parts Hot Dip Galvanized (Is: 2633 1986 ) Suitable For 16Mm B&S 70Kn Disc Insulators., Uts Of Hardware = 7000Kg Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Compression Type Repair Sleeve Suitable For Aaac Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Panther Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , Compression Type Repair Sleeve Suitable For Acsr Zebra/Moose Conductor Of 37/3.15Mm Designation With Body And Keeper Made Of Aluminum Alloy For Providing Reinforcement Of Conductor With Broken/Damaged Aluminum Strands. Repair Sleeve Should Conform To Is: 2121/1981 (With Latest Amendments Up To Date) And Should Present A Smooth Surface After Compression Min Failing Load = 95% Uts Of Conductor = 7654Kg Compression Pressure = 100Tons For Al Electrical Resistance At 20Oc =75% Of Measured Resistance Of Equivalent Length Of Conductor Corona Formation Voltage = 110% Of Max Line To Ground Voltage , 4R Stock Bridge Type Vibration Damper Suitable For Aaac :Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Aaac Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/3.15Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , 4R Stock Bridge Type Vibration Damper Suitable For Acsr Panther (Of 37/2.88Mm Designation) Of Approved Design. The Clamps And Keeper Of The Vibration Damper Shall Be Made To Al Alloy So Designed As To Prevent Any Damage To Or Chafting Of The Conductor, During Erection Or Continued Operation. Clamping Bolts, Washers Should Of Mild Steel/Hdg Provided With Self Locking Nuts Designed To Prevent Corrosion Of The Threads. All Ferrous Parts Including The Messenger Cable Shall Be Hot Dip Galvanized (Is 2633). The Ends Of Messenger Cable Shall Be Effectively Sealed To Prevent Corrosion. Spring Washers Should Be Electro Galvanized Dampers Mass Should Be Of Cast Iron Hdg Conforming To Is 9708 Of 1980 Total Wt Of The Item Shall Be = 2.4Kg, Slip Strength = 2.5Kn Before Fatigue Test, Slip Strength = 2.0Kn After Fatigue Test , Mid Span Compression Joint For Acsr Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/3.15Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Aaac Panther (Of 37/2.88Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Zebra (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Mid Span Compression Joint For Acsr Moose (Of 54/7/3.18Mm Designation) Suitable For Making Joints In The Conductor So Designed That On Installation No Air Space Is Left Within The Finished Joint. The Al Sleeve Used Should Be Of Extruded Al Tube Of Purity Not Less Than 95% While As Steel Sleeve Should Of High Strength Steel.Minimum Failing Load (Slip Strength) = 95% Uts Of Conductor = 7654Kg, Outer Sleeve = Extruded Al Tube Of 99.5 % Purity , Inner Sleeve = High Tensile Steel, Elect Resistance At 20Oc = 75% Of Measured Resistance Of Equivalent Length Of Conductor, Ferrous Parts = Hot Dip Galvanized , Compression Rate = 100Ton For Ac , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Zebra To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Acsr Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Armour Rods Helically Twisted Suitable For Aaac Panther To Provide Rigidity And Protection To The Conductor At All Suspension Parts And Also To Eliminate The Fatigue On The Conductor Due To Vibration And Corona.Type : Performed , Material Al/Al Alloy ,Purity Of Al : Ec Grade 95.5%,Corona Formation:110% Of Max Line To Ground Voltage , Consilic Strength 35Kg/Mm2, Slip Strength 25% Uts Of Conductor , Ends :Ball Ended, Erection Of Lay Of Rods :Right Hand Lay , Disc Insulator 70Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 70Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 90Kn B&S Type, Without Anti Fog(Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 120Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Anti Fog (Reputed Make/ Already Use In Pdd) , Disc Insulator 160Kn B&S Type, Without Anti Fog (Reputed Make/ Already Use In Pdd) , Gi Nuts And Bolts Of Sorts (16Mmx35mm/ 40Mm/45Mm/50Mm & 65Mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx75mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (10Mmx50mm) Heavy Duty , Gi Nuts And Bolts Of Sorts (12Mmx50mm) Heavy Duty , Aluminium Cable Tray Of Size 400 Mm X3000 Mm , Aluminium Cable Tray Of Size 300 Mm X2500 Mm , M.S. Angle Iron Of Size (45X45x5)Mm , M.S. Angle Iron Of Size (50X50x5) Mm , Steel Tor Of Dia 8Mm , 10Mm, 12Mm For Cable Ducts , Spring Washers 16Mm Heavy Duty , G. I Wire Swg No. 8/ 4.06Mm Dia , Red Oxide Enamel Paint (Asian, Nerolac/ Berger) , Al. Paint (Asian, Nerolac/ Berger) , Smoke Grey Enamel Paint (Asian, Nerolac/ Berger) , Yellow/White Paint (Asian, Nerolac/ Berger) , Cement Permier (Asian, Nerolac/ Berger) , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 Pg Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T-Clamps 3 Bolt Type Conforming To Is: 5561-1970 (Amended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc/ As Per Departmental Sample Provided , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975 T- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975 Bimetallic Ct- Clamps Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther With Clamp Sutitable For 132/33Kv CtS Of Ae Mumbai, Sct Gaziabad, Bhel Vidhyut Control Andhra, Mehru Bhiwadi/ Laxmi Engg Bhopal, Jyoti.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Ct Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Ct Terminals Suitable For 220/132Kv/33Kv Cts Of Makes/Ae Mumbai, Sct Gaziabad, Bhel, Vidhyut Control System Andhra, Mehru Bhiwadi/ Laxshmi Engg Bhopal, Jyoti, Equilent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132/33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S, Gr Power, Skipper, Bimco.Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Metallic Twin Isolator Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Isolators Of East Land, Elpro, Hivelm Calcutta, S&S,Gr Power, Skipper, Bimco,Andhra Mech. Industries Etc Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bi-Mettalic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra Conductor With Pad Terminals Suitable For 220/132Kv /33Kv Breakers Of Sf 6 Type-Abb,Cgl, Siemens, Bhel/Vcb Type- S&S, Gec Alsthom, Bhel, Abb, Siemens, Megawin Etc. Likely Makes: Rul, Zi, Honeywell, Burma, Pee, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic Twin Breaker Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Panther Conductor With Pad Terminals Suitable For 132Kv /33Kv Breaker Of Sf6 - Cgl, Abb, Siemens , Bhel Vcb- S&S, Gec Alstom, Bhel, Abb, Siemens, Equivalent Etc , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Zebra Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Moose Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , Al. Alloy As Per Is: 617 Of 1975, Bimetallic La Twin Pad Clamp (Universal Take Off) Conforming To Is: 5561-1970 (Ammended Upto Date) And Those Stipulated In Section-Iii Of This Tender Document Suitable For Acsr Panther Conductor Having Bolts Hot Dip Galvanized Nuts And Washers Electro Galvanized And Current Carrying Capacity Equivalent To Ampacity Of Zebra/Moose Conductor With Pad Terminals Suitable For 132Kv /33Kv La , P.I. Clamp For Acsr Zebra Conductor , P.I. Clamp For Acsr Panther Conductor , P.I. Clamp For Acsr Moose Conductor , P.I. Clamp For Acsr Moose Conductor , Twin Bushing Clamp Acsr Moose For 132/33Kv Transformer 1200Amp Without Poles , Twin Bushing Clamp Acsr Moose For 220/132Kv Transformer 1200Amp Without Poles , Isolator Jaw 1600Amp For 33Kv Isolator , Isolator Jaw 2500Amp For 33Kv Isolator , Isolator Jaw 1600Amp For 132Kv Isolator , Isolator Jaw 2500Amp For 132Kv Isolator , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 245Kv, 50C/S , 1600 Amp, 40Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 145Kv, 50C/S , 2000 Amp, 31.5Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators Without Earthing Blades , 36Kv, 50C/S , 2500 Amp, 25Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type 3 Pole Isolators With One Earthing Blades , Jumpers Cone For Acsr Panther , Jumpers Cone For Acsr Zebra , Spacers For Acsr Zebra , Spacers For Acsr Moose , Spacers For Acsr Panther , Earth Wire Tension Clamp , Electrical Items And Spares , Shunt Capacitor Fuse 40A With Spring Complete Assembly , Silcagel Crystal Size 8- 8 Mesh , Silcagel Breather Box 10Kg , Aluminium Tape , Chemical Jelly , Grease , Distilled Water , Transformer Oil Sampling Bottle , Welding Electrodes Swg 8No As Per Is: 814 Of 2004 , Welding Electrodes Swg 10No As Per Is: 814 Of 2004 , Search Light With 300-500Mtr. Focus Make Flash, Equivalent Etc , Led Flood Light Complete 90/100Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 140/150Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Flood Light Complete 1900/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Street Light Fitting 190/200Watt (Philips, Syska, Havells, Crompton, Bajaj Make) , Led Lamp 9 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Led Lamp 15 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 18 Watt (Philips, Havells, Crompton, Bajaj /Reputed Make) , Led Lamp 45 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Lamp Holder Pendant/Angular (Anchor,Havells,L&T,Philips/Reputed Make) , Led Tube 4 Pin 18 Watt (Philips, Havells, Crompton, Bajaj/Reputed Make) , Mcb 5-10 annual periodical maintenance Two Pole (Havells, Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Two Pole (Havells,Anchor,Standard, Hpl) , Mcb 10-16 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 32 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mcb 63 annual periodical maintenance Four Pole(Havells,Anchor,Standard, Hpl) , Mccb 100 Amp, 4 Pole, Ics= 100% Icu (Havells, Standard, L&T) , Mccb 200/400/600Amp,4Pole,Ics=100% Icu(Havelles,Standard,L&T) , Main Iron Clad Switch Tpn 415V,400A , Rubber Mat 1Mtr X2mtr= 12Mm Thick , Cable Ferrules A To Z And 0 To 9 , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 300Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Copper Mesh (30Cmx5cm) , Copper Wire 8Swg , Copper Thimbles 8Mm , Copper Thimbles 10Mm , Alumunium Thimbles 2.5 / 6 Mm , Alumunium Thimbles 8 / 10 Mm , Fhelmet , Starter 36Watts , Tube Four Pin 36 Watts , Choke 36Watts , Rubberized Cork Sheet 6Mm , Rubberized Cork Sheet 10Mm , O-Rings For Bushings/Inspection Plates Of Transformer 5Mm-10Mm Diameter , Rubber Sealings For Marshalling Kiosks/Control & Relay Panels , Cooling Fans Of 3 Phase 50Mva , 33Kv Vaccum Interrupter Suitable For 33Kv Vcb Of Bhel,Abb,Gec Alstom,Seimens,Megawin, S&S Make , Thermal Overload Relay Seimens Make With Range 0.8-1.2 annual periodical maintenance , Thermal Overload Relay Seimens Make With Range 1.2A-2.5 annual periodical maintenance , Thermal Overload Relay Seimens Make Of 4A Max With Range 0.1-1Amp And 1.5A-1.2A , Mn2 Thermal Overload Relay With Start And Off/Reset Relay Of Range 0.9-1.5A L&T Make , Relay 500V,2A, Fuse 6Amp. Mn2 Make L&T , Relay 415V,3.2-5A,Class 10A Mn2 Makesiemens 3Ua50 00-1F , Relay 415V,Lth=10A,Le=4A Mn-A1 Make L&T , Dc Change Over Relay Dcco, Make Abbrxme-1-Rk221-052-Annrk711004 , Dc1 Supervision Make Abb Tsr-In352 , Anti Pumping Relay Make Schrack/Abb Or Equi , Auxillary Relay, Voltage Selection Relay 75A, Rxpsu14n-Imyn563646-Dau, Aux Voltage:110V Dc, Case Size:2S 12C, Contacts:13No+1Nc, Reset Type:Electrical, Flag:Yes, Make Abb , Auxillary Relay, Tc-1 Supervision Relay195, 7Pj1321-5Aa210aa0, Aux Voltage:24-23V Dc, Contacts:2C/O, Reset Type:Self Make Siemens , Numerical Relay, Dir. O/C & E/F Protection Relay67/67N 7Sj6611-5Eb90-1Fgo-Lor, Aux Supply:110/250V Dc, Case Size:1/3 19,16 Bi, 7 Bo,1 Life Contact,4*I, 4*U,Ct:1A, Vt:110V/220V,50Hz, Iec61850, 100 Mbit Ethernet, Electrical, Double, Rj45-Connector Make Siemens , Thermostat Make Apt/Veilco/Eq , Auxiliary Air Break Contactor Of Ac2/Ac3 Duty Cycle Number Of Poles 03, Voltage 415V, annual periodical maintenance 0-2 A, Contacts 2No+2Nc,Make Siemens , Magnetic Control Contactor Make Andrew Yule Power 44W Volt 110V Dc Ith 10A Is 13947 Iec 947 , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mnx12 Make L&T , Contactor 415V, 12Amp Lth 10Amp,Le 4Amp Mna1 Make L&T , Contactor 415V, 20Amp 3Tf31 01-0A Make Siemens , Contactor 415V, 9Amp Lth 10Amp,Le 4Amp Mnx9 Make L&T , Auxillary Contactor 3Th3022-0B-F4, Aux Supply:110V Dc, Contacts:20O-2Nc 89Ax Make Siemens , Cooling Fans 3 Phase Motor,415V,560Watt,900Rpm,0.9Amp/1Amp(Size 600Mm) , Cooling Fans 3 Phase Motor,415V,700Watt,550Rpm,1.5Amp(Size 600Mm) , Digital Oti 90-250V Ac/Dc, Range 0-150Degree Make Precimeasure Control Banglore , Digital Wti Meter Make Precimeasure Control Banglore , Megawatt Meter , Digital Megawatt Meter, Bezel Size: 96*96Mm, 4-1/2 Digits, Aux Supply:110V Dc, Accuracy:0.5, Ctr:1200:800-400/1A Ptr:33Kv/110V Make Ae , Mvar Meter Digital Mvar Meter, Bezel Size:96*96Mm, 4-1/2 Digits, Aux Supply: 110V Dc, Accuracy:0.5, Ctr:1200-800-400/1A Ptr:33Kv/110V Make Ae , Ammeter Digital Ammeter, Bezel Size:96*96Mm, Aux Supply:110V Dc, Accuracy: 0.5, Range:1200-800-400/1A, Inbuilt Selector Switch Make Ae , Selector Control Switch Er Make 1224 Swiso , Digital Ac Ammeter,Makeae Digital 4, Range 0-600A, Ct Ratio 600/1A, Size 130X130 Mm. , Electronic Hooter, Aux. Supply 110V Dc, Freq. 48-63 Hz, O/P95-105 Db Size 96X96x82 Mm. , Lubricator Make Sae80w/90 Type Oil , Glass Sleeves , Crc Bottle , Teflon Tape , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Outdoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Single Core 63Sq Mm 33Kv Heat Shrinkable Cable Kit Indoor Type Likely Make M Seal, Powertech, H-Seal, Universal Etc , Fan Contactor Seimens Ice 158.1 Auxiliary Contactor 2No+2Nc & 4No+ 4Nc , Seimens 3Ta6702 2 To 10A, Auxilairy Contactor 3No+2Nc,Cs3-P Iec947 En60947 V=6Kv Ac-1 690V-1A Ac-15 , Solder Flux , Single Core 300Sq Mm 33 Kv Voltage Grade,Al Conductor, Pvc Insulated, Sheathed, Armoured, Xlpe Cable Likely Make Havelles Etc , Pvc Unarmoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 2 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 4 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 6 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 8 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 10 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 12 Core , Pvc Armoured Copper Control Cable 2.5Mm Sq 16 Core , Pvc Copper Wire 1 Mmsq , Pvc Copper Wire 1.5 Sqmm , Pvc Copper Wire 2 Sqmm , Pvc Copper Wire 4 Sqmm , Pvc Copper Wire 6 Sqmm , Copper Glands 19/25/32Mm , Switch 5A , Switch 15A , Socket 5 Pin, 5A , Socket15 Pin, 5A , Fan Regulator 10A , Dp Switch 32A , Pvc Tape Roll , Indicating Pygmy Lamp 220V/110V Dc, Pin Type / Screw Type , Semaphore Indicator For Isolator S89a Ntc12, Aux Supply:110V Dc, With 3Kohm, 6W External Resistor Make Dav , Push-Button & Indicating Lamp For Ann. Accept 3Sb50 00-0Ab01+ 3Sb54 00-0A, Normal Actuator With Plastic Front Ring And Black Holder Contact (1N0+1Nc) , Auxillary Switch 8No+ 8Nc Make Shirka/Shubhada/Eq , Local Remote Switch Make Shirka/Switron/Kaycee , Rotary Switch, Local Remote Switch 8 Ways, Handle:Pistol Grip, Position:Local/Remote, Stay Put, (Local-4Ways, Remote-4 Ways), 25A; Lockable Type, Bezel Size:75 Sq.Mm , Limit Switch 3Se3 023-0A, Contacts:1No+2Nc Make Siemens , Control Switch Bcs 3 Position ,Pistol Grip 16 Ways Make Switron , Control Switch Bcs 3 Position ,Pistol Grip 20 Ways Make Switron , 3 Core 95 Sq Mm 11Kv Xlpe Cable , Sf-6 Gas Cylinder Of 9Kg , Sf-6 Gas Cylinder Of 11Kg , Nitrogen Cylinder Of 16Kg Containing 9Kg Gas , O2 Cylinder Refilling , Anti Rodent Device , Control Switch For Panels Reputed Make , Hrc Fuse 2Amps , Hrc Fuse 4Amps , Hrc Fuse 6Amps , Hrc Fuse 10Amps , Hrc Fuse 10Amps , Hrc Fuse 32Amps , Hrc Fuse 32Amps , Hrc Fuse 100Amps , Fuse 3Nw20nnsf+3Nwns10, Aux Voltage:110V Dc, Rating:10A Make Siemens , Fuse 3Nw20nnsf+3Nwns4, Aux Voltage:110V Dc, Rating:10A Make Siemens , 33Kv Phase Limb Of 33Kv Circuit Breaker (Abb Make) , Breather Box For 133.33 Mva/160 Mva/150Mva, 220/132 Kv Transformer (Bhel/Abb Make) , Breather Box For 50 Mva,132/33 Kv Power Transformer (Bhel/Cgl/Ece/Emco Make) , Numerical O/C And E/F Relay Make:Easun Reyrolle , Model: Mit 114,Poles:4No,Volt: 43-280V Dc,Amp:1A , Numerical Differential Relay For Power Transformer Protection Make Ashida,Er/Reputed Make , Master Trip Relay B24,110/125 V Dc Make Er/Reputed , Master Trip Relay B24,220 V Dc Make Er/Reputed , Master Trip Relay 86, Rxmvb2-1Myn563035-Ad Make Abb , Trip Relay Supervision Relay 95 Tsr-1N352-001-As, Make Abb , 33Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt :33Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 66Kv Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 66Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A , 132 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt 132Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 220 Kv Voltage Grade, 3 Phase, 4 Wire Digital Trivector Energy Meter.. Volt : 220Kv/√3/110V/√3 , Frequency:50Hz, Rating: -/1A,Accuracy Class: 0.2S, Standard: Is 14697, Iec 62053-22 , 2 Pole Heavy Duty Rotary Switch With Off 5Amp Make Key Cee Equivalent Etc For C&R Panel , Shunt Tripping/Closing Coil 110V/220V Dc, Suitable For 33Kv Vcb Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make Etc , Shunt Tripping/Closing Coil 110V/220V Dc,Suitable For 66Kv Sf6 Of Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make,Equivalent Make , Spring/Charging/Closing Coil 220V/110V Dc, Suitable For 33Kv Vcb Bhel, Abb, Megawin, Alstom, Siemens, S&S, Cgl & Aluminum Industries Ltd.Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 33 Vcb Of Abb Make , Shunt Tripping/Closing Coil 220V Dc(Make Jyoti) ,Suitable For 132 Sf6 Of Abb Make , Tnc Switch 110/220V Dc 4Ways , Tnc Switch 110/220V Dc 8Ways , Tnc Switch 110/220V Dc 12Ways , Vrla Battery 12V,80/160Ah Along With Charger , Space Heater Sh100w240, Rating:100W 240V Ac Make Apt Control , Resistor Unit For Master Trip Relay 86 Rxtma-1Nrk711004-Aa Make Abb , Geared Motor For 100-130V Dc/Ac 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Geared Motor For 220-250V Ac For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Spring Charge Motor 230V Ac/Dc , 1.8A, Type Sg105, Insulation Class B, Rpm 60 For 36Kv Vcb Make Agni/Shreem/Reputed Make , Spring Charge Motor 230V Ac/Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Spring Charge Motor 230V Ac/Dc 2.5A For 132 Kv Sf6 Circuit Breaker (Siemens Make) , Auxilliary Contactor 110V Dc For 36 Kv Megawin Circuit Breaker Type Msp36 , Operating Coil 24V Dc maintenance of For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 maintenance of Opening Coil 48V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(110V-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Open Coil Mo1(220-250V Dc/220V-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shunt Closing Release-Mc 24V Dc For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mc Closing Coil(48V Ac-Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(110-132V Dc) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mc Closing Coil(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 24V Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly 48V Ac- Dc Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mu Coil Assembly(110-132V Dc/110-127V Ac) Undervoltage For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Vd4 Mu Coil Assembly(220-250V Dc/220-250V Ac) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 24Vcc Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(48Vca-Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly(110-127Vca/110-132Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Mo2 Assembly 220-250Vca/220-250Vcc) Additional Trip For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Shock Absorber Assembly For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Acsr Zebra Conductor , Acsr Panther Conductor , Acsr Moose Conductor , El3 Drive Complete(Operating Mechanism) For 36Kv Vcb Type Ovb-Vbf 36.16.25 Make Abb , Transformer Oil , Motor Operated Change Over Ac240v/Dc220v 100 annual periodical maintenance (Breaker Type) , Singhle Phase 50 C/S, Outdoor Metal Oxide Gapless Type ,30Kv(Rms) Surge Arrester Including Surge Counter/Monitor,Insulating Base Plate And All Associated Assessories Auxilliares , 33Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95Kvp Dry Lightning Impulse Withstand Voltage ± 170 (Kvp) , 132Kv Post Insulators Solid Core Type, Power Frequency Withstand Voltage 275Kvp Dry Lightning Impulse Withstand Voltage ± 650 (Kvp) , Single Phase 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries. , Single Phase, 50 C/S 145Kv Current Transformers (900-600-300/1-1-1-1-1 A Or As Per Site Specifications), 31.5Ka For One Second, Rated Dynamic Current 100Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S 132Kv Capacitor Voltage Transformers (132/√3) Kv/ (110/√3)V, One Min Power Freq Withstand 275Kvrms , Single Phase, 50 C/S 36Kv Current Transformers (1200-600-300 /1-1-1 A Or As Per Site Specifications) , 25Ka For One Second, Rated Dynamic Current 25Ka(Peak), Class A Insulation, Burden 20 Va , Single Phase, 50 C/S Outdoor 33Kv Pt (33/√3) Kv/ (110/√3)V With Highest System Voltage36kv, One Min Power Freq Withstand 70Kvrms , Marshalling Kiosk With Kiosk Frames Mild Steel Structural Sections For Pressed And Shaped Cold-Rolled Sheet Steel, Thickness Not Less Than 2.0 Mm. Frames Shall Be Enclosed In Cold-Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Doors And Covers Shall Also Be Cold Rolled Sheet Steel Of Thickness Not Less Than 1.6 Mm. Complete Structures Shall Be Rigid, Self Supporting, Free From Flows, Twists And Bends. Dust And Vermin Proof Construction And Shall Be Provided With A Degree Of Protection Of Ip: 55, With Copper Bar Earthing. Finishing Paint On Panels Shall Be Of Shade 692 (Smoke Grey) Of Is: 5. The Inside Shall Be Properly Stoved. The Paint Thickness Shall Be At Least 50 Microns , Single Phase 36Kv 50 C/S, Outdoor Metal Oxide Gapless Type, 120Kv (Rms) Surge Arrestor Including Surge Counters/Monitors, Insulating Base All Associated Accessories, Auxiliaries , T&P Items And Safety Equipments , Turn Table For Acsr Panther/Zebra Conductor With Capacity Of 3Mt Made Of Mild Steel With Double Ball Bearing Likely Makes Pee, Zi, Honeywell, Burma Etc , Four Sheeve Pulley Steel Frame Forged Swivel Hookwith Capacity Of 5Mt As Per Is 8610 Pulley Material And Ball Bearing Of Gun Metal Bush With Open Type Pulley Isi Mark Suitable For 12Mm Steel Rope , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/3.15Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Aaac/Panther Conductor 37/2.88 Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp Suitable For Zebra Conductor 54/7/3.18Mm With Al Alloy Clamp And Groove Inside For Conductor Gripping. Hook And Eye Bolt Of Galvanized Carbon Steel, Locking Bolts Made Of High Tensile Steel Is: 2121 Tension Limits = 2495Kg Likely Makes Pee, Zi, Honeywell, Burma Etc , Bolted Type Come Along Clamp For Earth Wire Size 7/3.66Mm Groove According To Size Of Earth Wire Bolts Of High Tensile Steel Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Galvanized Pulley Size 6 Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing. , Al Alloy Snatch Roller Pulley Size 8Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Trans Line Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Snatch Roller Pulley Size 6Dia Pulley On Ball Bearing/Gun Metal Bush With Swivel Hook Open Type With Side Locking Suitable For Use In Earthwire Stringing Likely Makes Pee, Zi, Honeywell, Burma Etc , Tool Kit , D-Shackle Heavy Duty , Chain Block Pulley Heavy Duty 5 Ton , Avo Meter Likely Make Motwani, Waco, Riken Etc , Hook On Meter Likely Make Motwani, Waco, Riken Etc , Insulating Hand Gloves Make Crystal Etc Tested For 220 Kv, 132 Kv , 33Kv Level , Safety Helmet Isi Marked , Safety Belt Isi Marked , Safety Vest Isi Marked , Rain Coat Of Duck Back Make Etc , Safety Shoes Of Reputed Make Etc , Fixed Piller Drill Machine 40Mm , Polypropylene Rope ½, ¾& 1 / Garware Make , Manila Rope ¾ & 1 Dia , Steel Wire Rope Sling 16Mm Dia Isi Make 2 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 5 Mtr. Long Heavy Duty , Steel Wire Rope Sling 16Mm Dia Isi Make 10 Mtr. Long Heavy Duty , Steel Wire Rope Of Dia 16 Mm , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 220Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 132Kv Voltage Level , Discharge Rod Suitable (Complete With Connecting Lead & Clamp) For 33Kv Voltage Level , Hydraulic Conductor Cutter , Hydraulic Compressor Manually Operated For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Hydraulic Compressor Motorised For Jointing Aaac/Acsr Conductor With Operating Handle Pressure Gauge, Tools Accessories Kit And Weather Proof Cover For Protection. Capacity: 100 Ton, Make: Techo Scient/Reputed Make. , Compressor Die Sets Suitable For Above Hydraulic Compressors , Drum Lifting Jack Mechanical 3 Ton Capacity , Single Sheeve Pulley Both Open And Close 5 Ton Capacity , Double Sheeve Pulley 5 Ton Capacity , Three Sheeve Pulley , Petrol Chain Saw Cutter , Earthing Roller , Equilizer Pulleys 10 Ton , Earth Wire Pulley , Single Sheeve Roller Aluminium, Rubberized Dia 300/400 Mm , Single Sheeve Roller Aluminium, Dia 450/600 Mm , Twin Aerial Roller, 150Mm (Rubberized) Aluminium , Twin Aerial Roller, 150Mm (Rubberized) Nylon (P.P) , Patta Clamp , Kitto Clamp , Turn Buckle Capacity 5 Ton , Joint Proctector For Various Conductors , Sagging Winch Machine 10 Ton , Single End Socks , Double End Socks , Earth Wire Socks , Power Winch Machine 5 Mt , Sag Plate , Single Pulley 150Mm Dia (Aluminiun/ P.P) , Automatic Clamp For Conductor/ Opgw , Crow Bar, 30Mm To 32 Mm , Derrick Pole, S-Type Roller , Air Compressor With Ac Single Phase Air Cooled 12 Cfm Compressor And Tank Pressure 100 Psi Make Maxair/Reputed Make , Paint Spray Gun 45Psi , Old Cotton Saree , Digital Mutltimeter (Mutli Functional Meter) , Military Grade Binocular (Reputed Make) Magnification Between 7X To 12 X And Objective Lense Diameter , Axe/Sickle , Professional Chain Saw 58Cc, 20 Inches, 3.75 Hp , Bush Cutting Machine Heavy Duty (Reputed Make) , Meggar , Earth Tester , Digital Insualtion Tester , Earth Test Field Kit , Oil Bdv Kit , Thermovision Camera Having Resolution 640*480, Wavelength 8-14Um, Thermal Sensitivity =0.05°C , Automatic Identification Lens With Manual/Electric/Automatic Focusing, Fov- 25°X19°; High Brightness Sunlight Screen, With 4X Digital Zoom, Hdmi Output, 500Million Pixels, Laser Positioning Points Displayed On The Image,With 32Gb Memory Space, Video Recording, Temp Range: -2O Degree To 650 Degree Centigrade, Having Rechargaeble Liyhium Ion Battery , Primary Injection Kit With 1000 Amperes Rating Accuracy ±0.5% Power Supply(Ac) 220V±10%·25A, 50Hz/60Hz Or 110V±10%·50A, 50Hz/60Hz Current Output (Ac) 1000A·5V Or 500A·10V Capacity 5Kva The Current Output Waveform Distortion ≤5% Dual Protection Overload Electronic Protection And Software Protection Range 0-1100A Resolution 0.1A, Accuracy 0.5%, Secondary Measurement Range 0-6A Resolution 0.001A, Accuracy 0.5%, Current Duration 1000A Range 1000A 2-3Minutes 500A 3-6Minutes 500A Range 500A 2-3Minutes Continuous Output 0-400A With Timer Range 0.0001~999.99S Resolution 0.001S Accuracy 0.2% ±2 Words Standard Standard Iec61010-1;Iec 61326-1 Communication Port Rs232 Cable Length 2X6m, 70Mm² , Cgi Sheet , Spanner Set , Fire Fighting Equipments , Refilling Of Dry Powder 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 15Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 25Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Dry Powder 50Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 2Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 5Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Abc Type 10Kg (Make Freeze Fire,K V Lite /Reputed Make) , Refilling Of Mechanical Foam Type 50 Ltrs (Make Freeze Fire/Reputed Make) , Refilling Of Co2 Type 4.5 Kg , Refilling Of Co2 Type 10 Kg , Refilling Of Co2 Type 12.2 Kg , Refilling Of Co2 Type 22.5 Kg , Hose Pipe For Dcp 10 Kg , Hose Pipe For Dcp 25 Kg , Hose Pipe For Dcp 50 Kg , Hose Pipe For Abc 2 Kg , Hose Pipe For Abc 5 Kg , Hose Pipe For Abc 10 Kg , Hose Pipe For Mechanical Foam Type 50 Ltrs. , Hose Pipe For Co2 4.5 Kg , Hose Pipe For Co2 22.5 Kg , Wheel Set For Dcp 25 Kg , Wheel Set For Dcp Co2 22.5 Kg , Wheel Set For Dcp/Mechanical Foam 50 Kg , Union Cap For Dcp 10Kg , Union Cap For Dcp 25Kg , Union Cap For Dcp 50Kg , Dry Powder Fire Extinguisher 25 Kg Trolly Mounted Filled With Bc Dry Powder Fitted With Hose Pipe/ Nozzle Is No: 10658 Used On B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Type Fire Extinguisher 6Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Abc Stored Pressure Multipurpose Typefire Extinguisher 9Kg Wall Mounted Filled With Map Mono Ammonium Phosphate Powder 90% Complete With Hose Pipe/ Nozzle Is No: 14609 Used On A, B & C Class Of Fire Make Cease Fire,Savemax,Reputed Make , Carbon Dioxidetype Fire Extinguishers Seamless 4.5 Capacity Wheel Type Fitted With Isi Marked Value, Hose/Horn Filled With Co2 Gas Applicable On Class B,C Fires Is 15683 Make Cease Fire,Savemax,Reputed Make , Mechanical Foam 50 Ltrs. Fire Extinguishertrolly Mounted Filled With Afff Concentrate Fitted With Hose Pipe/ Nozzle Is No: 13386 Used On A & B Class Of Fire Make Cease Fire,Savemax,Reputed Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
30.
Health and Family Welfare #11073758 Technical Bid
Tender For Major Works At Girls Ashram Hostel Merpur Kotda Udaipur- 1 Dismantling Doors, Windows And Clearatory Windws Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead: For Thickness Of Tiles 10Mm To 25Mm. 3 Dismantling Gi Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes And Including Stacking Of Pipes Within 50 Meter Lead: 4 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 5 Grading Roof For Water Proofing Treatment With Water Proffing Compound. Cement Mortar 1:4 (1Cement : 4 Coarse Sand) 6 Providing & Laying Broken Glazed Titles On Roof ( Broken Glazed Tiles Not Less Than 9 Kg/Sqm) On Top Of Hot Bitumen @ 1.7 Kg/Sqm. (1.40 Kg Of Vg-40 (30/40 )Grade And 0.30 Kg/Sqm. Of Vg-10 (80/100) Grade) And Joints Filled With Cement Mortar 1 :2 (1 Cement:2 Marble Dust Mixed With Water Proofing Compund All Complete As Per Direction Of Engineer-In-Charge. 7 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) 8 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) 9 Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete.New Plastered Surface (Three Or More Coats) 10 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 11 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 12 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete 13 Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Sqm Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3Mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge 14 Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). 15 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10Cm Long Embedded In Cement Concrete Blocks 15X10X10 Cm Of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 16 Providing And Fixing M.S. Sheet 1Mm Thick Dabble Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint Add Extra For Double Leaf Shutters. 17 Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150Mm Distance. 18 Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. 19 Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Aldrop Of Mild Steel 12\ Long X12Mm Dia 20 Steel Hinges For Wooden Chowkhat 4\ Size. 21 Steel Handle 6\ Size 22 Labour Charges For Repair To Door / Window Without Using Any Material Such As Applying Randha (Finishing) Tightening Of Bolts & Screw Etc. 23 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 24 Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated „J‟ Or „L‟ Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. 3.0Mm Thick (Wt. 5.0 Kg./Mtr. Sq.) 25 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: 26 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 28 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 30 Providing And Laying Ceramic Mat Floor Tiles (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown Of Any Size, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440Mm. 32 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 15 Mm Nominal Size 33 20Mm Nominal Size 34 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(External Work).15 Mm Nominal Size 35 20Mm Nominal Size 36 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 75 Mm Dia 37 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 38 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia 39 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Coupler (Socket) 160 Mm Dia 40 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee 160 Mm Dia 41 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Tee 110Mm Dia. 42 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 110Mm Dia. 43 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 160Mm Dia. 44 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 110Mm Dia. 45 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 160 Mm Dia. 46 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Bend (Top Side) 110Mm Dia. 47 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 110Mm Dia. 48 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 160Mm Dia. 49 P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design. 1000 Litres Capacity. 50 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 15Mm Nominal Bore. 51 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 25Mm Nominal Bore. 52 Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick C.C Bed Of 1:5:10, M-15 Grade C.C Floor & Rcc Slab Covering With M15 Grade C.C. Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140X150 Cm.(For 50 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect 53 Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. 54 P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall :Size 550 Mm X 400 Mm 55 P & F Looking Mirrors With P.V.C. Frame Of Approved Make As Per Direction Of Engineer-In-Charge Size 500X400Mm 56 P & F Grating Of Approved Quality/Make:Stainless Steel Sheet Size 125Mm Dia. 57 P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: Brass 400 Gm,15Mm Nominal Bore. 58 Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade C.C. Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead.Depth Up To 0.5 M 59 Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick C.C. 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.-Do- Size 450 X 450Mm Depth Upto 0.5 M Cement Cover With Frame 60 Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.C Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth . 61 P & F Flush Cock / Flush Valve (Is : 9758 Mark) For Wc Of Approved Quality Make : (-Do-) Half-Turn Exposed 25Mm Nominal Bore. 62 P& F Waste Coulping With Fittings Of Approved Quality /Make: C.P Brass 32 Mm Dia 63 P& F Waste Pipe With All Fitting G.I(B Class) 32Mm 64 Construction Of Open Drain With 112Mm Thick Brick Masonry In Cm 1:4 Semi Circular S.W. Glazed Channel (Confirming To Is Standards) Fixed With Cement Mortar 1:1 Over A Bed Of 100Mm Thick C.C. 1:5:10, Filling Of Edged With M-15 Grade C.C. Flooring, 12Mm Cement Plaster 1:4, Over All Exposed Faces, Excavation & Disposal Of Earth With In A Lead Of 50 Mtr Complete As Per Approved Drawings : 150 Mm Drain,225Mm Av. Depth Width 15 Cm S.W. Glazed Channel. 65 Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 150Mm 66 Supply Of Erw M.S. Black Casing Pipe Isi Marked (Is:4270/1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 150 Mm Nominal Bore Of Pipe 67 S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size: 150Mm Dia 68 S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. 69 Providing & Fixing Of Hdpe Pipe Confirming To Is:4984:2021 For Water Supply Suitable For Submersible & Jet Pump With Required Fittings Ie Socket, Elbows, Tee Etc. Complete In All Respect. For Vertical Installation 63 Mm Od 6 Kg / Cm2 70 For Horizontal Installation 63 Mm Od 4 Kg/ Cm2 71 Sitc Of Radial / Mixed Flow Water And Anti-Corrosive Liquid Filled Submersible Motor Pump Sets Suitable For 100/150Mm Dia Borewell. The Size Of Adopter Fixed On Top Of The Motor Should Exceed The Top Of Coupler , For Safegaurd The Coupler. The Job Includes Labour Part Of Lowering Of Riser Pipe G.I./ H.D.P.E. With Rope, Cables & Pump, Installation Of Complete Fitting And Accessories, Jointing Of Electrical Cables Up To Starter. All Labour For Testing Of Submersible Pumps Set And Supply Of Water To Water Mains, Complete In All Respect. 100 Mm Diameter Submersible Pump Shall Have Following Hp Rating, Phase, Head Range, Discharge Range Respectively. 3.0 Hp, 1-Ø, (40 -170)Mtr, (60- 20) Lpm Copper Wound 72 Sitc Of Ip 54 Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Coordination Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection(For Three Phase Pumps), Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps, 2P/4P Mcb Etc. Suitable For Following Rating Motors Complete In All Respect. For Three Phase Submersible / Mono Block Pump 3.0 Hp To 5.0 Hp ( Dol Starter ) 73 Providing & Laying Of Polypropylene Rope Confirming To Is:5175 For Submersible Pump Of Following Sizes. Complete In All Respect. 20Mm (Suitable For 90 Mm Od Pipe) 74 Supply And Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. 10.0 Sq.Mm 3 Core Flat / Round 75 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) 76 Medium Point (Up To 6 Mtr.) 77 Long Point (Up To 10 Mtr..) 78 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 79 Medium Point (Up To 6 Mtr.) 80 Long Point (Up To 10 Mtr..) 81 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 82 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Blanking Plate 83 Modular Mcb 6 A To 32 A Dp (Is:8832 Marked) 84 Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. 5 Step Fan Regulator 2 Module 85 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 X 1.5 Sq.Mm 86 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 87 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm 88 2 X 6.0 Sq. Mm. + 1 X 2.5 Sq. Mm 89 4 X 10.0 Sq.Mm 90 4 X 6.0 Sq.Mm 91 1 X 16.0 Sq.Mm 92 1X 4.0 Sq.Mm. 93 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Glazed Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way 94 Glazed Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 12 Way (12+2) 95 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating 96 Double Pole Mcb(With B/C Curve Tripping Characteristics) 40 A Rating 97 Four Pole Mcb(With B/C Curve Tripping Characteristics) 50/63 A Rating 98 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners Etc. As Required. 32 Mm X 12 Mm 99 Making Of Hole In Wall (Brick/Stone) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Up To 457 Mm Size 100 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 101 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 300 Mm Sweep(900/1400 Rpm) 102 P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Required. Up To 380 Mm Size 103 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm 104 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1600 Lm 105 Minimum Lumen Output 1950 Lm 106 Sitc Of Ip20, 1X1 Led Surface/ Recessed Mounting Backlit & Smd Mid Power Type Led Light Fixture Not Less Than 35 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution.Operating Voltage Range 140-285 V, Hv Cutoff - Lv Cutoff Should Be 300-100V High Efficiency With 4 Kv Internal Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. Surface Moutning Minimum Lumen Output 3600 Lm 107 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 108 Providing & Fixing Of Extra Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Required. 109 Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be 110 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. 300 Mm Sweep 111 Supply And Installation Of High Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copper Thickness (250 Microns) And Confirming To Ul 467, Is/Iec 62561-2 Of Following Size And Length And As Per Point Mentioned (A), (B), [C), (D), (E) Below :- (A) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole (B) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts © Connect The Rod With Copper Strip/Conductor/Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt (D) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Test Certificates For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 17.2 Mm Thick And 3 Mtr. Long 112 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. 8 Swg Copper Wire 113 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led/ Integrated Lens Diffuser & Should Be High Power Led Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Integrated Metal Case Potted Driver & Has A Unique Bis R Number ( As Per Is 15885) With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac & Low Voltage Cutoff @>=90 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs As Required. Led Street Light Fixture With Minimum Lumen Output 2500 Lm 114 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. 32 Mm Dia. 115 Supply & Fixing Of Dry Powder Agent (As Per Is 4308:2019), Abc Type Fire Extinguisher (Stored Pressure Type) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test (For Cylinder Body) Certificate From Oem / External Nabl Accrediated Lab Is To Be Submitted. 6 Kg 116 Sitc Of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day 117 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs 118 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 119 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 120 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). 121 Kerb Stones Of 1200X300X150, 1000X450X150, 1000X600X150, 600X300X150 Size (M-30) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade (Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W/C Ratio In Concrete Mix. Manufactured With Steel Moulds (Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy) On Steel Base Plate Of Min 16 Mm Thick; Having Vibration And Pressing Action Both Together With The Help Of Multiple Synchronised Vibrators. Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Making Of Joints, Drainage Opening Wherever Required. 122 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 123 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 124 Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 125 Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 126 Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 127 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 128 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. 129 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) 130 Random Rubble Stone Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Five Level Above 30Cm. Thick Walls In : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 131 Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 25 Mm Thick. 132 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 133 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 134 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 135 Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size).
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
31.
Rural Development #11068023 AOC
Tender for special repair To Police Station Building Nuagaon For The Year 2025-26; 1.10 Earth work excavation in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth asper direction of the Engineer-in-charge 2.00 Supplying and filling in foundation & plinth with sand in 23.5 cm (9) thick layers including watering and ramming with cost, conveyance, royality taxes of all materials, and labour with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge. 3.00 Providing Cement Concrete (1:3:6) with 40mm size crusher broken granite metal of approved quality from approved quarry including hoisting lowering & levelling in position to required level in each layer not exceeding 15cm thick in foundation including frame work where necessary ramming using vibrator to proper slope and levelling curing dewatering with cost conveyance taxes royality, labour of all materials, with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge 4.00 Fly ash brick masonary in Cement Mortar (1:6) in Foundation using Fly ash brick of 25 cm X 12 cm X 8 cm size having a crushing strength not less than 75kg per Sq.cm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering & curbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge 5.00 Cement concrete of proportion (1:2:4) using 12mm (1/2) size clean crusher broken grantie chips of approved quality from approved quarry including hoisting lowering and levelling in position to required level including frame work where necessary ramming and levelling cruing dewatering with cost conveyance taxes and royalties labour of all materials including hire and running charges of machineries T&P required for the work with cess etc, complete as per specification and direction of Engineer-in-charge. 6.00 Providing 12mm thick cement plaster in all floors at all height with cement mortar of mix (1:6) with approved grade cement and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonary walls after racking out the joints including watering and curing, rounding of corners etc. completer with cost, conveyance, loading, unkloading, royalty and taxes of all materials, cost of all labour T&P, sundries and scaffolding required for the work with providing grooves as per specification and direction of the Engineer-in-charge.Face of Plinth Protection wall 7.00 PS side building 8.00 Finishing wall surface two coats with any approved weather coat over a coat of wall primer to outer wall surface after celaning surface including cost of paint and primer watering curing with cost conveyance and taxes of all materials and labour with T&P and Cess required for the work etc, complete in all respect as per the direction of Engineer-in-Charge. 9.00 Wall painting two coats with plastic Emulsion paint of approved quality & shade on new work to give an even shade with brush to interior walls surface after cleaning the surface including cost of plastic emulsion paint with cost, conveyance and taxes of all materials and labour with T&P required for the work with CESS etc complete as per direction of Engineer-in-Charge.
Contract Date: May 12, 2026 Contract Value : 1.43 Lakh
Government Departments No of Bidders 22
32.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
33.
Defence #11051111 AOC
Bids Are Invited For Rigging Items For Asw Swc Yard By 524 Dock Tackle 3.6 M Length , Chain Hook , Shock Mitigation Strops Set Of 2 , Fairlead Shackle , Towing Pendant Or Chafe Piece , Check Stopper With Ss Thimble , Dumping Mat , Steady Tackle , Tray , Crowbar , Station Marker Box , Electronic Display Board , Signal Bats Solid Red , Signal Bats Solid Green , Signal Bats Solid Amber , Signal Bats Solid White , Wand Red Signal , Wand Green Signal , Wand Amber Signal , Wand White Signal , Loudhailer , Shot Mat , Double Rescue Strop , Boat Rope Toggle , Chemiluminescent Sticks Red, Green And Amber Each , Whistle , Ras Flag , Fueling Board , Safety Net For Gangway With Safety Net Label Information Swl Of 2T , Screw With Slip 0.75 T , Drop E Pin With Keep Chain High Tensile , Drop E Pin With Keep Chain 3 Mm Dia , Mooring Eyes Protection , Bridles Eye Protection , Hpmt Or Qec Foul Weather Lines , Hpmt Splicing Tools , Twines 0.5 Mm Dia , Cordage Stopper With Thimble Mmfc , Cordage Stopper With Thimble Nfc , Gun Line Cylindrical Containers 50 Cm , Heavy Duty Chopper Ms With Wooden Handle , Wooden Piece , Anchor Buoy , Metallic Scrubber , Mousing Wire 1.22 To 1.5 Mm Dia , Rope Polyamide 3 Stranded , Polyamide Gun Cord Line , Quick Release Pin , Cradle 2 Tier , Strap For Cradle 2 Tier , Link Triangular Or Coat Hanger , Eye Plate , Hydrostatic Release Gear , Canvas Bag , Distance Line , Bridles X2 , Shocking Mitigation Strops X2 , Stainless Steel Fairlead Shackle X4 , Buffers Tooth Brush , Securing To Buoy Strop X2 , Bollard Strop And Slip , Chafe Sleeve X2 , Shackle Straight With Split Pin 16Mm , Bow Shackle With Split Pin 22Mm , Shackle Straight With Split Pin 19 Mm , Elongated Link , Jumping Ladder , Pilot Ladder , Trollies For Material Movement , Srbf Block , Wellings Spring Hook , Bulldog Grips For Swr , Rigging Screw Without Slip Total Quantity : 296
Contract Date: Ref. Documents Contract Value : 9.77 Lakh
Government Departments No of Bidders 4
34.
Shipping #11000549 AOC
Bids Are Invited For Providing Illumination On Harbour Wharf Road,Idk Of Mumbai Port Authority Total Quantity : 1961; SITC of Outside light fittings on Shed structure alongwith allied Electrical and Mechanical works. PART A Supply and delivery at site 3C x 2.5 mm² PVC/PVC, 1100 volts grade armoured, multistranded copper conductor cable. Installation / laying of Cable mentiond at Sr. No. 1 along with 12 SWG GI earth wire on the Shed structure/frame/ Periphery/ Outside wall of shed by using adequate No. of spacers/saddles/ L-clamps made out of GI material of suitable size including termination & connecting all the ends of cable(loop in & out) by using appropriate size copper crimping lugs and cable termination glands at looping box and earthing wire complete to the instructions. Outside light point to be terminated in a SMC type cable looping box (all weather & Water proof with IP 66 & above) with in-built brass terminals/4 way connectors(loop in & loop out) and 01 no. 6 Amp SPMCB to be fixed on Shed structure/ Periphery/ Outside wall of shed to the instructions. Supply and Delivery of LED flood light luminaire in die cast aluminum housing,250 W (each) with shroud, luminous efficacy of not less than120 lm/w. having IP 68, suitable to operate on 230 V, 50 cycle A.C. supply as per specifications. Supply and Delivery of LED flood light luminaire in die cast aluminum housing,125 W (each) with shroud, luminous efficacy of not less than120 lm/w. having IP 68, suitable to operate on 230 V, 50 cycle A.C. supply as per specifications. Installation testing & Commissioning of tripple LED flood light fitting(item sr.no. 4 & 5) on the G.I. Bracket (sr.no 8) along with mounting /fixing arrangement by using suitable size of GI clamps,screws & GI nut bolts etc. as per instructions,drawings & specifications. Supply and Installation of 3 core PVC/PVC flexible copper conductor cable of 2.5 sq. mm from the Junction/looping Box up to the luminaries including termination of the cable to both the ends, including the supply and installation of copper cable lugs & suitable glands etc. and to the instructions. Supply and Delivery of G.I.Bracket suitable for installation of three flood light fittings alongwith suitable size and length of GI down Pipe on outside MS structure of Shed 13B, Shed 13A & Shed 15 as per the specifications/ drawings with required GI clamps, nutbolts including cutting, welding for suitable fixing arrangement as per the site requirement and to the instructions. Installation of item sr. no. 8 with necessary GI clamps/GI Nut bolts and allied work of welding, brazing etc. including installation & commissioning as per drawing & specifications to the instructions. PART B Supply & delivery of Outside Lighting control panel made out of S.S. enclosure grade 304, 14 gauge, IP 66, internally embedded gasket with provision for cable entry through glands. The control panel must be of appropriate size to accommodate the following switch gears with interconnecting wiring between the switchgear by using PVC insulated PVC sheathed or sleeved copper conductor wires / busbar. The control panel shall be provided with necessary locking arrangement with Brass Padlock and wall mounting type on S. S. angle frame of suitable size & height and shall comprise of the following items with necessary clearances. 1) Switch Fuse Unit (40A)- 01 No, 2) Digital Astronomical Timer 24 Hrs - 01 No, 3) TP Contactor 40A with 230 V operating coil-01 No, 4) Energy Meter (Next Gen)- 01 No, 5) DPMCB 20 A -04 nos. 6) Manual/Timer selector switch 6A-01 No, 7) Connectors: 3 sets (3-Ph & N) out of which 1 set for 4Cx 10 mm² & 04 sets for Ph and N 3 C x 2.5 mm² cable, 8) Provision for Earthing connection to the control panel & 9) Door operated LED Panel light of 5 watts, 230 V. The Manufacturer shall submit a copy of test report for degree of ingress protection as per IEC 60529. Installation of the outside Light Control Panel at Sr No. 10 above on the wall of shed with suitable GI Frame and to the instructions. Supply & delivery of PVC/ XLPE insulated armoured PVC sheathed cable of sizes 4C x 10 sq .mm. with copper conductor heavy duty 1100 volts grade confirming to IS 1554/7098 (part –I) of 1998. Laying & Installation of the armoured cable(item sr.no.12) with copper conductors,1100 volts grade on the even surfaced wall/beam/ceilings/MS structure by providing appropriate sizes of G.I. saddles and G.I. spacers or clamps as per Mb.P.A. Specifications.(From Main supply source at Switch room west side to Outside Lighting Control Panel installed on East side wall of shed 13 B & 13 A) & (From Main supply source at Switch room East side to Outside Lighting Control Panel installed on wall of shed 15). Supplying and making two (1 pair) ends of cable termination and connection with single compression type brass glands and copper lugs for 4 CX 10 sq. mm. of PVC/XLPE - A - PVC cables with copper conductor,1100 volts grade and to the instructions. Supply & Delivery of Sheet Steel TPN Switch Fuse Unit, 63Amps, 415V along with 63 Amps, 415V HRC fuses suitable for terminating both the end of PVC/XLPE armoured cables of size 4 C x 10 sq.mm, 1100 volts grade with copper conductor with necessary opening, earthing terminals. Installation, Testing & Commissioning of Sheet Steel TPN Switch Fuse Unit, 63A on existing board at Main switch chamber along with interconnecting cable of 4 C x 10 sqmm. between Busbar & TPN SFU 63A at sr.no 15 above with allied work to the instructions. Earthing pit by auguring and installation of Copper Coated electrolytically bonded 250 micron MS Earth Rod of 17.2 mm dia. 3 mtr long Earth enhancement compound 50 Kg. connector for testing link complete with inspection chamber made out of brick masonry and cast iron inspection cover duly painted and marked. The resistance of earthing station shall be tested with calibrated Earth Resistance Tester and results recorded as required. The earthing system shall interconnect between earth electrode to the instructions. Supply & Delivery of Material Installation, Testing & commissioning
Contract Date: Ref. Documents Contract Value : 29.65 Lakh
Government Departments No of Bidders 5
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 4.11 Lakh
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
38.
Defence #10908707 AOC
Tender For Addition/Alteration To Certain Married Accn At Air Force Station Pathankot Under Ge (Af) Pathankot.; 1 Schedule A Part-I (Building Works) 2 M&L for preparation of surface byscrapping and properly cleaning the surface to remove loose particles/existing vegetation/roots etc. with wire brushes and removing any type of existing roof treatment in any layer alongwith existing plaster so as to reach up to top of RCC roof slabcomplete in all respect , filling of cracks with Smart Care Hybried PU sealent wherever required for rendering or plastering work 10 mm thick in CM 1:3 on roof surfaces and finishing the surface without using extra cement for application of roof treatment(A) Apply first coat of fibre reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun reflectivity index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 MPa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure , reduce surface temperature upto 10 degree celsius with 33% dilution as primming coat. (b) Laying of fibre mesh of 0.3mm thickness weave in leno pattern having weight 45 gm/Sqm and pasting it properly with overlap of 50mm and allow it to dry. (c) Apply second undiluted coat @ 0.450 ltr/Sqm(d) Apply third and final coat undiluted @ 0.450Ltr/Sqm in color combination/ cameoflauging patternas directed by Engr-in-charge. Note : Application of water proofing treatment will be done Authorised applicator only/ or in presence of authorised rep. Certificate in this regard shall be submitted to Engr-in-charge. Shifting/removal of any wire/ cable/AC unit/water tank or any other object as per the site requirement and refixing of the same if needed is deemed to be included in rates quoted by contractor. 3 S&F in repair 150mm dia PVC (SWR) pipes single socketed in any lengthfixed to wall including clamps, bends, sockets, as required complete all as specified and directed by Engr-in-Charge. 4 S&F for rotational triple layer moulded polyethene water storage tanks of capacity 500 litres, (cylindrical vertical with closed top) hoisted and fixed in position including necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nutetc complete including dismantling existing RCC/Iron/PVC water tank all as specified and directed. 5 S&F for rotational triple layer moulded polyethiene water storage tanks of capacity 1000 litres, (cylindrical vertical with closed top) hoisted and fixed in position including necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nutetc complete including dismantling existing RCC/Iron/PVC water tank all as specified and directed by Engr-in-Charge. 6 S&F for 20mm bore Steel water tubing medium grade, galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed by Engr-in-Charge. 7 Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast RCC articles and disposal of debris out of MoD land complete all as specified and directed by Engr-in-Charge. 8 M&L brick work with sub class B burnt bricks straight or curved on plan 6m mean radius built in cm 1:6complete all as specified and directed by Engr-in-Charge. 9 Material and labour for high depth cladding coloured glazed ceramic tiles rustic-matt type in vertical surface such as gate piller, dado, etc 450mmX 300mmX 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles over and including 10mm thick rough cement plaster to receive tiles in CM 1:4 complete aall as specified and directed by Engr-in-Charge.Note:-The texture ,colour ,Shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by Engr-In-Charge and Rates also including in this item for necessary raking circular cutting or notching and waste on tiles. 10 Demolition of Roofs, floors (other than ground floors), beams,staircases,landings, chajjas,RCC Water tank similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition) and disposal of debris out of MoD land complete all as specified and directed by Engr-in-Charge.Note:- Demolition will be done only by mechanical cutter only . 11 M&L for RCC Slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs Design MixM-25 (20 mm graded aggregate) set in CM 1:6, as in slabs for Water tank base size as required etc with plain fair faces incl necessary formwork complete all as specified and directed by Engr-in-Charge. 12 M
Contract Date: Jan 15, 2026 Contract Value : 1.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
39.
Power #10900196 AOC
Bids Are Invited For Erection Of 132 Kv Sunsure Solar Park Gj One Pvt Ltd Bay (2*Main+1*Trasfer Bus Scheme) On Deposit Head At 220Kv Kabrai Under Etd Hamirpur; 1 Erection of Main and auxiliary structure consisting of columns, beams, peaks, masts etc. and auxiliary structure required for installation of isolators, C.Ts. P.Ts. L.As. and all other equipments. All material to be erected shall be supplied by UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost. a 132KV side (Main & Auxilary structure) b Shifting of all material equipment from store to site to work site like breaker,CT,Isolatoretc. by hydra/conventional means 2 Erection of following equipments 01 no.132kV Bay of M/s Garda Solar Bay at 220kV Substation Charkhari i 145 KV Circuit Breaker ii 145 KV Potential Transformer iii 145 KV Current Transformer iv 145 KV Post Insulator v 145 KV Line Isolator (Motorised) without polycone vi 145 KV Bus Isolator (Motorised) without polycone vii 145 KV Tendem Isolator (Motorised) without polycone viii 120 KV L.A. ix CT Junction Box x PT Junction Box xi 132 KV Simplex feeder C&R Panel (SAS Based) xii Meter Cubical with 02 No. ABT Meter 3 Jumpering ,interconnection of equipment with specified conducter of various 132kV equipments with main and transfer bus bar.The work includes cutting and bending of conducter in proper shape clamping with the help of the clamps and shifting of material from store room to erection site to work site and all other associated to complete the work at 132kV line bay 4 Cutting,strengthening,bending,laying 600mm.below in side ground and above ground of following size of MS Flat for earthing of main and auxiliary structure, equipment structure and its material etc. Including welding with main earth mat and with object to be earthed /excavation of trenches its back filling painting and all other associated work. Excluding cost of MS Flat i 75X10mm ii 50X6mm iii 25X6mm 6 Preparation of interconnection diagram of various connection between CB, CT, PT & CRP etc. 7 Laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and JB etc. In switchyard as per cable schedule. i 2C x 2.5 Sq mm. unarmoured. ii 4C x 2.5 Sq mm. unarmoured. iii 6C x 2.5 Sq mm. unarmoured. iv 10x2.5 Sq mm. unarmoured. 8 Termination of various sizes of above laid control cable as per cable schedule including making necessary holes in glands plates or box where ever required supply and fixing of cable glands of appropriate size, supply & providing ferrules & Nos for each core of cable and its termination with crimping type lugs of dowell/tension make and all other associated work to complete the job satisfactory. 9 Making earthing of LA including work of digging of soil upto 1 Mtr depth or as per reqirements removel of stone and brick work if required. Making 06 no holes in soil across structure of 132kv side LA. Fabrication minimum 3 mtr long electrodes from 40mm dia MS round having one side conical shape. Placing of electordes and laying of 75x10 mm MS flat as per drawing or site condition including work of shifting of material cutting, bending, drilling and welding at joints of 75x10mm MS flat and 40mm round etc. Connecting the newly made delta by X - Y MS round of existing earthmate as per drawing with the help of 75x10 mm MS flate. Back filling of soil etc. Making connection of LA/surge counter by riser from 75*10 ms Flate as per standard approved drawing . 10 Cutting, Fabrication and fixing of angle iron by welding including cost of electrodes, labour, T&P. Details of every job includes- (a) Taking out scrap angle heap of scrap, cutting the cleats of 50x50x6mm angle iron & shifting back the scrap (b) Fixing of cleats of angle iron by welding including cost of electrodes, labor, T&P. 11.1 Fabrication of 3M long Electrode with 40MM dia M.S. rod having 150mm long conical shape and then its piercing vertically in side the ground with top 600mm.below ground level and its welding with earthmat, excluding the cost of M.S. bar. 11.2 Boring with 150 mm Dia casing pipe to a depth of 27.00 meter long from ground level with skilled and unskilled labour including all T&P, boring apparatus and supervision charges etc. required for proper completion of work. By Inserting 40x6 mm GI Flat in 50 mm Dia B-class (Jindal) ISI mark 6.0 meter long 3 pipe placed horizontally on ground and bolting the G.I flat with 150 mm long 75x6 mm copper plate conical piece on and then bolting the G.I flat with G.I pipe in such a way that flat remains in contact with the pipe, Lowering of 6.0 meter long with G.I pipe with conical copper plate connected and at bottom along with G.I flat inside the pipe in boring of 150 mm G.I pipe pieces by G.I sockets along with 40x6 mm G.I flat from the upper end of pipe by making a cut of 45 mm wide up to a depth of 50 mm in upper portion of G.I pipe and providing 01 no. cap type G.I socket on upper treaded portion of pipe for water pouring in the pipe at regular intervals filling the space. 11.3 Excavation of pit of size 2.00x2.00x4.5 driven of M.S electrodes of 40/36/32 mm dia 3.0 mtr long in the earth at four corners of the pit at equal distance of 2.0 mtr long, keeping the top of electrode 50 cm above the pit ground level, welding of 40 mm M.S round pieces of 03 mtr long on all four sides of electrodes and 15 cm below of top of electrodes by 08 nos U type clamp of 50x6 mm G.I flat on opposite side of square welding of 40x6 mm G.I flat on opposite M.S electrode driven in ground and connecting the 40x6 mm G.I flat. MS Flat will be provided by department free of cost as per actual consumption. 11.4 Interconnecting work of connecting bore earth point with near by Main structure of 132 KV Gaintry of 132 KV Sunsure Gj seven bay equipments with MS Flat of size 50x6 mm. This work includes laying, cutting, bending, welding and painting of MS Flat with one coat of Red oxide primer and two coats of Green colour of standard make like Nerolac, Berger, Asian etc. 12.1 Supply and fixing of 120 watt LED Lamps Cropmton Greaves, Bajaj/Havells make fitting including lamp, Ballast Igniter etc. For fixing of structure including cost of all material labour and T&P for completion of work. 12.2 Supply and fixing of Junction Box on lighting polls of size 200x200x150mm of MS seat SWG duly painted with synthetic enamel paint box should be fixing and Backlite terminal strip of 4 Nos terminal both should be fixing on Sunmica seat and half round MS clamp with GI pipe for fixing the Junction box on the structure 12.3 Supply and fixing of 16 Amp. MCB make Crompton Greaves, Bajaj/Havells make fitting on structure including cost of all material, labour and T&P for completion of work. 12.4 Laying of 2x2.5/4x2.5mm sq.mm PVC cable 50 cm below the ground level in PVC conduit pipe after excavation and back filling including all labour PVC pipe etc. 13 Laying the 01 Nos. 4x2.5 Sq. mm control cable for CT & PT with provision of vermin proofing in galv. MS pipe in individual B Class pipe of Jindal/TATA/JSW/SAIL, 1 dia with jointing with Tee, Elbow, bend, Socket etc. Including cost of material of pipe and other accessories. Separate pipe will be made in trench for each control cable. Control cable will be provided by the department as per actual consumption. 14.1 Supply of AC Power Receptacle with rating 3 phase 415 volt 400 Amp cubical shall be of size 1550x800x500mm with MS sheet thickness not less than 14 SWG duly power coated of good quality. The receptacle shall be provided with manually operated 1 no. 400 MCCB L&T make, 03 nos. aluminium insulated bus bar of size 25x10mm for 3 phase and 1 no. for neutral having size 25x5mm 3 no. kit kat fuses, 3 no. R/Y/B indicators for all phases L&T make. The cubical fitted with two no. 3 phase four pole TPN MCB 63 Amp and 12 nos. 3 phase four pole TPN MCB 15 Amp suitable for giving supply to 33 KV Breakers, Isolators, Lighting fixtures etc. The cubical shall have the provision of visual indication of incoming supply & indoor light fitting 09 Watt LED with the power cubical shall be weather proof. 14.2 Fixing of 03 Phase AC Power Recaeptacle of size 1550x800x500mm by fabricating proper frame to hold it and grouting the same with help of fasteners on block of concrete having 30 cm above ground level with mixture of 1:2:4 at the location decided by the supervising engineer.The box should consists of cable gland duly fitted in gland plate fixed on the bottom of cubical box with proper locking arrangement. work includes carriage of power receptacle to the location, inclusive of cost of labour and T&P required to complete the job satisfactorily. 14.3 Laying of 3.5Cx95/75/50 sq.mm LT Power cable 60 cm below the ground level after excavation and put the 1st class bricks and river sand along side of cable and back filling with proper termination on cables at both end complete with Lugs, Glands etc. of proper size. (Work includes cost of Labour and T&P required to complete the job under the guidance of Junior engineer incharge, required power cable will be provided by the department.) 14.4 Earthing of panel with the help of MS Flat of size 50x6 mm and connecting it with earth mat including digging and back filling and ramming as per UPPTCL practice. MS Flat will be provided by department free of cost as per actual consumption. 15 Providing & fixing work of Name Plate made of 2mm thick aluminium sheets with covering of 3HP retroreflective sheeting of size 300x150 mm plate to be fixed with the help of nuts & bolts of already installed equipment , structures as per sample, provided by department free of cost. 16 Providing & fixing of Phase Plate equipment (R,Y,B) phase made of 2mm thick aluminium sheets with covering of 3HP retroreflective sheeting of size 5 dia plate to be fixed with the help of nuts & bolts of already installed equipment , structures as per sample, provided by department free of cost. 17 Calibration of metering system (03Ct+03PT+02 Energymeter) of 132 kV M/s Sunsure GJ Seven bay at 220kV S/s Charkhari by reputed NABL accridated Laboratory with recomommanded instrument with proper calibration Certificate including prepration of test report at site 18 Misscellaneous work of Carriage of required materials like Control Cable, MS Flats, MS Round Bar and other important items from different Sub-Stations under ETC Banda as per requirement. 1 Single Tension Fittings Suitable for i ACSR Panther 2 Single Suspension Fittings Suitable for i ACSR Moose 3 PG clamps suitable for - i Moose/Panther ii Moose/Moose 4 Bus Post Clamps suitable for- i Moose 5 Terminal connector suitable 145kV CT for MOOSE conductor 6 Terminal connector suitable 145kV PT for MOOSE conductor 7 Supply of Flexible Copper Bond made of electrolyte copper rope of size 37/7/0.457 having length 750mm tinned copper lug shall be pressed jointed both end of copper bond 8 Supply of Fire bucket stand made of angle iron, size 40X40X6 mm having arrangement for having 10 nos. buckets on suitable hooks made of M.S. sheets of 18 S.W.G. and printed with post office red enamel paint. The stand should be as per site requirement. 9 Supply of Fire bucket having 9 ltr. Capacity and painted with red color paint from outside & white color paint from inside written with FIRE on outer surface. 10 Supply of Hot dip galvanized Cable Tray 18 SWG having weight 225mm as per technical specification. 11 Supply of Hot dip galvanized Cable Tray 18 SWG having weight 75mm as per technical specification. 12 Manual dry chemical Carbon Di-Oxide Fire extinguishers (4.5Kg) 13 Manual Carbon Di-oxide Fire extinguishers (22.5Kg) 14 Manual Carbon Di-oxide Fire extinguishers (9.0Kg) 15 Manual Carbon Di-Oxide Fire extinguishers (4.5Kg) 16 Spacer suitable for Twin ACSR Moose conducter 17 Galvanized U Bolt 20mm dia. with double nut and washer 18 Cable dressing Saddle Clamp of size 25x3mm of aluminum flat with 200mm long bent suitable and having 2 No. holes at both end with galvanized nut bolt. 19 Self Supported Aluminium Ladder as per UPPTCL technical specification 21 LAN Cable 22 Nertwork switch (6CU+2FU) 16.1 40mm MS Rod for Main Earthmat 16.2 40mm dia MS Electrodes (3 M Long) 17 MS Flat for earthing i 75x10mm ii 50x6mm iii 25x6mm 20 Supply of 70kN Antifog Disc Insulator
Contract Date: Ref. Documents Contract Value : 22.62 Lakh
Government Departments No of Bidders 7
Uttar Pradesh View Result →
Contract Date: Jun 12, 2026 Contract Value : 7.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 3.48 Lakh
Government Departments No of Bidders 10
Contract Date: Apr 27, 2026 Contract Value : 4.64 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
43.
Power #10843341 AOC
Bids Are Invited For Work For Erection Of 01 No 132 Kv Enfinity Global Energy Innovations Pvt. Ltd. Bay (2*Main+1*Trasfer Bus Scheme) On Deposit Head At 220 Kv S/S Jaitpur Under Etd Hamirpur; 1 Erection of Main and auxiliary structure consisting of columns, beams, peaks, masts etc. and auxiliary structure required for installation of isolators, C.Ts. P.Ts. L.As. and all other equipments. All material to be erected shall be supplied by UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost. a 132KV side (Main & Auxilary structure) b Shifting of all material equipment from store to site to work site like breaker,CT,Isolatoretc. by hydra/conventional means 2 Erection of following equipments 01 no.132kV Bay of M/s Garda Solar Bay at 220kV Substation Charkhari i 145 KV Circuit Breaker ii 145 KV Potential Transformer iii 145 KV Current Transformer iv 145 KV Post Insulator v 145 KV Line Isolator (Motorised) without polycone vi 145 KV Bus Isolator (Motorised) without polycone vii 145 KV Tendem Isolator (Motorised) without polycone viii 120 KV L.A. ix CT Junction Box x PT Junction Box xi 132 KV Simplex feeder C&R Panel (SAS Based) xii Meter Cubical with 02 No. ABT Meter 3 Jumpering ,interconnection of equipment with specified conducter of various 132kV equipments with main and transfer bus bar.The work includes cutting and bending of conducter in proper shape clamping with the help of the clamps and shifting of material from store room to erection site to work site and all other associated to complete the work at 132kV line bay 4 Cutting,strengthening,bending,laying 600mm.below in side ground and above ground of following size of MS Flat for earthing of main and auxiliary structure, equipment structure and its material etc. Including welding with main earth mat and with object to be earthed /excavation of trenches its back filling painting and all other associated work. Excluding cost of MS Flat i 75X10mm ii 50X6mm iii 25X6mm 6 Preparation of interconnection diagram of various connection between CB, CT, PT & CRP etc. 7 Laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and JB etc. In switchyard as per cable schedule. i 2C x 2.5 Sq mm. unarmoured. ii 4C x 2.5 Sq mm. unarmoured. iii 6C x 2.5 Sq mm. unarmoured. iv 10x2.5 Sq mm. unarmoured. 8 Termination of various sizes of above laid control cable as per cable schedule including making necessary holes in glands plates or box where ever required supply and fixing of cable glands of appropriate size, supply & providing ferrules & Nos for each core of cable and its termination with crimping type lugs of dowell/tension make and all other associated work to complete the job satisfactory. 9 Making earthing of LA including work of digging of soil upto 1 Mtr depth or as per reqirements removel of stone and brick work if required. Making 06 no holes in soil across structure of 132kv side LA. Fabrication minimum 3 mtr long electrodes from 40mm dia MS round having one side conical shape. Placing of electordes and laying of 75x10 mm MS flat as per drawing or site condition including work of shifting of material cutting, bending, drilling and welding at joints of 75x10mm MS flat and 40mm round etc. Connecting the newly made delta by X - Y MS round of existing earthmate as per drawing with the help of 75x10 mm MS flate. Back filling of soil etc. Making connection of LA/surge counter by riser from 75*10 ms Flate as per standard approved drawing . 10 Cutting, Fabrication and fixing of angle iron by welding including cost of electrodes, labour, T&P. Details of every job includes- (a) Taking out scrap angle heap of scrap, cutting the cleats of 50x50x6mm angle iron & shifting back the scrap (b) Fixing of cleats of angle iron by welding including cost of electrodes, labor, T&P. 11.1 Fabrication of 3M long Electrode with 40MM dia M.S. rod having 150mm long conical shape and then its piercing vertically in side the ground with top 600mm.below ground level and its welding with earthmat, excluding the cost of M.S. bar. 11.2 Boring with 150 mm Dia casing pipe to a depth of 27.00 meter long from ground level with skilled and unskilled labour including all T&P, boring apparatus and supervision charges etc. required for proper completion of work. By Inserting 40x6 mm GI Flat in 50 mm Dia B-class (Jindal) ISI mark 6.0 meter long 3 pipe placed horizontally on ground and bolting the G.I flat with 150 mm long 75x6 mm copper plate conical piece on and then bolting the G.I flat with G.I pipe in such a way that flat remains in contact with the pipe, Lowering of 6.0 meter long with G.I pipe with conical copper plate connected and at bottom along with G.I flat inside the pipe in boring of 150 mm G.I pipe pieces by G.I sockets along with 40x6 mm G.I flat from the upper end of pipe by making a cut of 45 mm wide up to a depth of 50 mm in upper portion of G.I pipe and providing 01 no. cap type G.I socket on upper treaded portion of pipe for water pouring in the pipe at regular intervals filling the space. 11.3 Excavation of pit of size 2.00x2.00x4.5 driven of M.S electrodes of 40/36/32 mm dia 3.0 mtr long in the earth at four corners of the pit at equal distance of 2.0 mtr long, keeping the top of electrode 50 cm above the pit ground level, welding of 40 mm M.S round pieces of 03 mtr long on all four sides of electrodes and 15 cm below of top of electrodes by 08 nos U type clamp of 50x6 mm G.I flat on opposite side of square welding of 40x6 mm G.I flat on opposite M.S electrode driven in ground and connecting the 40x6 mm G.I flat. MS Flat will be provided by department free of cost as per actual consumption. 11.4 Interconnecting work of connecting bore earth point with near by Main structure of 132 KV Gaintry of 132 KV ENFINITY GLOBAL ENERGY INNOVATIONS PVT. LTD. bay equipments with MS Flat of size 50x6 mm. This work includes laying, cutting, bending, welding and painting of MS Flat with one coat of Red oxide primer and two coats of Green colour of standard make like Nerolac, Berger, Asian etc. 12.1 Supply and fixing of Junction Box on lighting polls of size 200x200x150mm of MS seat SWG duly painted with synthetic enamel paint box should be fixing and Backlite terminal strip of 4 Nos terminal both should be fixing on Sunmica seat and half round MS clamp with GI pipe for fixing the Junction box on the structure 12.2 Supply and fixing of 16 Amp. MCB make Crompton Greaves, Bajaj/Havells make fitting on structure including cost of all material, labour and T&P for completion of work. 12.3 Laying of 2x2.5/4x2.5mm sq.mm PVC cable 50 cm below the ground level in PVC conduit pipe after excavation and back filling including all labour PVC pipe etc. 13 Laying the 01 Nos. 4x2.5 Sq. mm control cable for CT & PT with provision of vermin proofing in galv. MS pipe in individual B Class pipe of Jindal/TATA/JSW/SAIL, 1 dia with jointing with Tee, Elbow, bend, Socket etc. Including cost of material of pipe and other accessories. Separate pipe will be made in trench for each control cable. Control cable will be provided by the department as per actual consumption. 14.1 Supply of AC Power Receptacle with rating 3 phase 415 volt 400 Amp cubical shall be of size 1550x800x500mm with MS sheet thickness not less than 14 SWG duly power coated of good quality. The receptacle shall be provided with manually operated 1 no. 400 MCCB L&T make, 03 nos. aluminium insulated bus bar of size 25x10mm for 3 phase and 1 no. for neutral having size 25x5mm 3 no. kit kat fuses, 3 no. R/Y/B indicators for all phases L&T make. The cubical fitted with two no. 3 phase four pole TPN MCB 63 Amp and 12 nos. 3 phase four pole TPN MCB 15 Amp suitable for giving supply to 33 KV Breakers, Isolators, Lighting fixtures etc. The cubical shall have the provision of visual indication of incoming supply & indoor light fitting 09 Watt LED with the power cubical shall be weather proof. 14.2 Fixing of 03 Phase AC Power Recaeptacle of size 1550x800x500mm by fabricating proper frame to hold it and grouting the same with help of fasteners on block of concrete having 30 cm above ground level with mixture of 1:2:4 at the location decided by the supervising engineer.The box should consists of cable gland duly fitted in gland plate fixed on the bottom of cubical box with proper locking arrangement. work includes carriage of power receptacle to the location, inclusive of cost of labour and T&P required to complete the job satisfactorily. 14.3 Laying of 3.5Cx95/75/50 sq.mm LT Power cable 60 cm below the ground level after excavation and put the 1st class bricks and river sand along side of cable and back filling with proper termination on cables at both end complete with Lugs, Glands etc. of proper size. (Work includes cost of Labour and T&P required to complete the job under the guidance of Junior engineer incharge, required power cable will be provided by the department.) 14.4 Earthing of panel with the help of MS Flat of size 50x6 mm and connecting it with earth mat including digging and back filling and ramming as per UPPTCL practice. MS Flat will be provided by department free of cost as per actual consumption. 15 Providing & fixing work of Name Plate made of 2mm thick aluminium sheets with covering of 3HP retroreflective sheeting of size 300x150 mm plate to be fixed with the help of nuts & bolts of already installed equipment , structures as per sample, provided by department free of cost. 16 Providing & fixing of Phase Plate equipment (R,Y,B) phase made of 2mm thick aluminium sheets with covering of 3HP retroreflective sheeting of size 5 dia plate to be fixed with the help of nuts & bolts of already installed equipment , structures as per sample, provided by department free of cost. 17 Calibration of metering system (03Ct+03PT+02 Energymeter) of 132 kV M/s ENFINITY GLOBAL ENERGY INNOVATIONS PVT. LTD. bay at 220kV S/s Charkhari by reputed NABL accridated Laboratory with recomommanded instrument with proper calibration Certificate including prepration of test report at site 18 Misscellaneous work of Carriage of required materials like Control Cable, MS Flats, MS Round Bar and other important items from different Sub-Stations under ETC Banda as per requirement. 1 Single Suspension Fittings Suitable for i ACSR Moose 2 PG clamps suitable for - i Moose/Panther ii Moose/Moose 3 Bus Post Clamps suitable for- i Moose 4 Terminal connector suitable 145kV CT for MOOSE conductor 5 Terminal connector suitable 145kV PT for MOOSE conductor 6 Supply of Flexible Copper Bond made of electrolyte copper rope of size 37/7/0.457 having length 750mm tinned copper lug shall be pressed jointed both end of copper bond 7 Supply of Fire bucket stand made of angle iron, size 40X40X6 mm having arrangement for having 10 nos. buckets on suitable hooks made of M.S. sheets of 18 S.W.G. and printed with post office red enamel paint. The stand should be as per site requirement. 8 Supply of Fire bucket having 9 ltr. Capacity and painted with red color paint from outside & white color paint from inside written with FIRE on outer surface. 9 Supply of Hot dip galvanized Cable Tray 18 SWG having weight 225mm as per technical specification. 10 Supply of Hot dip galvanized Cable Tray 18 SWG having weight 75mm as per technical specification. 11 Manual dry chemical Carbon Di-Oxide Fire extinguishers (4.5Kg) 12 Manual Carbon Di-oxide Fire extinguishers (22.5Kg) 13 Manual Carbon Di-oxide Fire extinguishers (9.0Kg) 14 Manual Carbon Di-Oxide Fire extinguishers (4.5Kg) 15 Spacer suitable for Twin ACSR Moose conducter 16 Galvanized U Bolt 20mm dia. with double nut and washer 17 Cable dressing Saddle Clamp of size 25x3mm of aluminum flat with 200mm long bent suitable and having 2 No. holes at both end with galvanized nut bolt. 18 Supply of 150 watt LED Lamps Cropmton Greaves, Bajaj/Havells make fitting including lamp, Ballast Igniter etc. For fixing of structure including cost of all material labour and T&P for completion of work. 19 Self Supported Aluminium Ladder as per UPPTCL technical specification 20 LAN Cable 21 Nertwork switch (6CU+2FU) 22.1 40mm MS Rod for Main Earthmat 22.2 40mm dia MS Electrodes (3 M Long) 23 MS Flat for earthing i 75x10mm ii 50x6mm iii 25x6mm 24 Supply of 70kN Antifog Disc Insulator
Contract Date: Ref. Documents Contract Value : 19.80 Lakh
Government Departments No of Bidders 9
Uttar Pradesh View Result →
Contract Date: Apr 08, 2026 Contract Value : 11.91 Crore
Government Departments No of Bidders 5
46.
Information and Broadcasting #10811892 Price Bid
Tender For E-Tender For The Supply, Installation, Integration, Testing, And Commissioning Of Equipment, Computer Hardware, Software, And Accessories For Cinematography, Digital Intermediate, Audiography, Direction & Screenplay Writing, Film Editing, And Animation & Visual Effects Sections, On Academic Pricing On Turnkey Basis, Along With Comprehensive Onsite Warranty For Three (3) Years , Direction And Screenplay Writing Section - Equipment Requirements , Smart Tvpc Dell Pro Max Tower T2 - Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W), 64Gb (2 X 32 Gb) Ddr5 (5600 Mt/S, Non-Ecc), Nvidia Geforce Rtx 5090 32Gb Gddr7, 3Xdp, 1Xhdmi, 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready/ Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 /Windows 11 Pro / 5 Yrs Support , Smart Tv Sony Bravia 3 Series 189 Cm (75 Inches) 4 K Ultra Ai Smart Led Google Tv , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , External Hard Drive Seagate One Touch 20Tb Usb 3.0 Portable Hdd , Printer Hp Laserjet Mfp M438Dn Multi-Function Monochrome Laser Printer (Toner Cartridge) , Directors Viewfinder Alan Gordan Enterprises Mark Vb Directors View Finder , Video Assist Monitors Blackmagic Video Assist 5 3G 5-Inch Full Hd Lcd Touchscreen 3G-Sdi And Hdmi Inputs/Outputs Supports Up To 1080P60 Recording , Final Draft Final Draft Software Full License (Industry Standard With Life Time License) , Continuity Camera / Script Notes Camera Canon Eos R50 Mirrorless Camera Body With Rf - S 18 - 45 Mm F/4.5 - 6.3 Is Stm , Walkie-Talkies, Head Phones (Sets) Aspera V-9 License Free Walkie Talkie With Standard Accessories Viz Battery, Belt Clip, Rapid Charger And Adaptor, Helifex Antenna, User Manual. , Portable Bluetooth/Monitor Speakers (On-Set Use) Jbl Xtreme 3, Wireless Portable Bluetooth Speaker, Pro Sound With Powerful Bass Radiators, Built-In Powerbank, Partyboost, Ip67 Water & Dustproof, Aux & Type C (Blue, Without Mic) , Digital Clap Board Tribe7 Blackslate7 7.5 Clapperboard E-Image Cb-03 Advanced , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Digital Intermediate Section - Equipment Requirements , Software Davinci Resolve Software Studio Version , Software Adobe Package Software (1 Year Subscription Yearly To Be Renewed) , Software Easy Dcp Software For Resolve , Color Correction Panel Black Magic Design Davinci Resolve Mini Panel , Color Correction Panel Black Magic Design Davinci Resolve Micro Panel , Imac Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse With 1-Year Support , Imac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16-Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Imac Mac Keyboard And Mouse Usb Hub 50000 X 1 No. , Dell Tower Work Stations Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non- Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Dell Tower Work Stations Logitech Mk120 Usb Keybord And Mouse , Dell Tower Work Stations Photoshop System 1 Year Licence Subcription To Be Renewed Annually , Monitor Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe , Monitor Dell Pro 27 Plus Monitor - P2725H / 5Y Basic Advanced Exchange Service , Monitor Eizo Cg319X-4K / 31.1 Inches,4096X2160,350Cd/M2,Dp,Hdmi,Adobe Rgb, Built In Sensor , Tv Sony Bravia 4K Uhd Tv 65Inch , External Hard Disk Samsung Ssd 4 Tb External Hdd , External Hard Disk Seagate One Touch Backup Plus 5Tb Hdd External , Di Equipments Blackmagic Design Capture, Card Ultrastudio 4K Mini , Di Equipments Black Magic Design Ultrastudio Monitor 3G For Mac 15000 X 4 Nos , Di Equipments Black Magic Design Link Card 4K Extreme 12G , Speaker & Headphones Jbl Stage 260F, Stage 245C, Stage 240H, Stage 200P + Denon Avrx- 250 Bituminous Av Receiver 5.1 Home Theatre , Speaker & Headphones Jbl Sb180 Speakers , Speaker & Headphones Akg K52 Headphones , Accessories Wacom Intuos Bluetooth Ctl-6100/K0-Cx Digital Graphics Pen Tablet For Drawing (Black) Medium (10.4-Inch X 7.8-Inch) , Accessories Hdmi 2.1 -5 Metres , Accessoriest Thunderbolt 4(Usb-C) Pro Cable (3 Metres) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Animation & Visual Effects - Equipment Requirements , System Lenovo Think Station Px Workstation | 2 X Intel Xeon Gold 5420+ Processor (2.00 Ghz Up To 4.10 Ghz) | 4 X 128 Gb Ddr5-4800Mt/S (Rdimm, Ecc) | 4 X 12 Tb 7200Rpm Hdd 3.5 Sata Enterprise | Nvidia Rtx A6000 48Gb | Intel Eagle Stream C741 Dual Processor Motherboard | Raid 10 (4 Drives Min) | 1 X 1 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | 1 X 4 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | Integrated Ethernet | 2 X Thermal Kit 250W | Windows 11 Pro 64Bit Pre-Loaded | Wired Keyboard & Mouse | 3 Years Onsite Warranty / Dell Ultrasharp 27 4K Thunderbolt Hub Monitor - U2725Qe , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5070 12Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Software Adobe Creative Cloud All Apps Education Named Subscription License , Software Ai Tools (Google Flow) , Software Davinci Fusion Studio Annual-Commercial , Software Cine Tracer , Software Autodesk Maya Subscription New- Commercial , Software Houdini Academic License , Software Nuke Studio 1-Year Subscription , Laptop Dell Pro Max 16 (Mc16250) Xcto Base / Intel Core Ultra 5 235H, Vpro Enterprise (18Mb, 14 Cores, 14 Threads, Up To 5.00 Ghz Turbo, 45W) / 16Gb: 2X8Gb, Ddr5, 5600 Mt/S, Sodimm, Dual Channel, Non-Ecc / Nvidia C64 Rtx Pro 1000 Blackwell 8Gb Gddr7 / 16 Fhd+ Lcd With 300 Nits, Non- Touch, Fhd Hdr Rgb Camera, Microphone, Wlan / Intel Wi-Fi 6E Ax211, 2X2, 802.11Ax, Bluetooth 5.3 Wireless Card / 512Gb, M.2 2230, Gen4 Pcie Nvme, Ssd, Class 35 / 130W Ac Adapter, Type C (Tco10) / Windows 11 Home / 5Yrs Prosupport Nbd , Smart Tv Smart Tv-32 Inch , Moniters Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe / 3Y Basic Advanced Exchange Service , Other Equipments Logitech Mk120 Usb Keybord And Mouse , Other Equipments Xp-Pen-Deco01 V3 , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Film Editing - Equipment Requirements , Apple Imac Machines Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , Apple Cinema Display 27 Apple Studio Display 5K Retina Display 68.29 Cm / 27 (Diagonal) 5K Retina Display 5120X2880 Resolution At 218 Pixels Per Inch 600 Nits Brightness Support For 1 Billion Colours Wide Colour (P3) True Tone Technology With 1-Year Support , Sennheiser Headphones Hd 280 , Jbl Studio Jbl Monitors/Speakers , External System Connected Ssd External Wd 1Tb Drive , Licenses For Each Software Avid Media Composer Edu 1-Year Subscription New License , Licenses For Each Software Davinci Resolve Software , Licenses For Each Software Fcp Studio , Licenses For Each Software Adobe Premiere Pro Academic License 1-Year Subscription - 3 Nos. , External Backup Hard Drive Wd My Book Backup Drive - 12 Tb , Keyboard/ Mouse Logitech Mk120 Usb Keybord And Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Audiography - Equipment Requirements , Dubbing/Mixing Room - Hardware And Software Protool Ultimate Edu Subscription For Student/Teacher - New , Dubbing/Mixing Room - Hardware And Software Dolby Atmos Renderer , Dubbing/Mixing Room - Hardware And Software Pace Ilok 3 Usb - C Type , Dubbing/Mixing Room - Hardware And Software Merging Techologies Hapi Mkiii , Dubbing/Mixing Room - Hardware And Software Merging Technologies Ada8V3S 8 Ch Mic/Line Ad&Da 192 Khz , Dubbing/Mixing Room - Hardware And Software Merging Technologies Anubis Pro Sps , Dubbing/Mixing Room - Hardware And Software Avid S1 (Includes 1 Year Hw Warranty) , Dubbing/Mixing Room - Hardware And Software Avid S1 Extended Hw Support - Second Year , Dubbing/Mixing Room - Hardware And Software Avid Dock , Dubbing/Mixing Room - Hardware And Software Focusrite Isa428 Mkii 4-Channel Microphone Preamp , Dubbing/Mixing Room - Hardware And Software Apple Mac Studio M3 Ultra Chip With 28-Core Cpu, 60-Core Gpu, 32-Core Neural Engine, 96Gb Unified Memory, 1Tb Ssd Storage, Macos , Dubbing/Mixing Room - Hardware And Software Applecare+ For Mac Studio (M4 Max / M3 Ultra) , Dubbing/Mixing Room - Hardware And Software Sonnet Rackmac Studio Enclosure - 3U Pro Rackmount Enclosure To Install And Secure One Or Two Mac Studio Computers In A Standard 19-Inch Rack , Dubbing/Mixing Room - Hardware And Software Logic Pro - Professional Music Production , Dubbing/Mixing Room - Hardware And Software Steinberg Nuendo 14 - Software (Standard) , Dubbing/Mixing Room - Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Dubbing/Mixing Room - Hardware And Software Samsung 65 Tv For Console Room - 1.63 M (65) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Samsung 55 Tv For Console Room - 1.38 M (55) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Lg 4K Uhd Hybrid Projector , Dubbing/Mixing Room - Hardware And Software Motorised Projector Screen, 10 X 8 Feet, 150 Diag, 4:3 Aspect Ratio, 1080P-3D-4K With Remote , Dubbing/Mixing Room - Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Dubbing/Mixing Room - Hardware And Software Blackmagic Design Ultrastudio Monitor 3G Sdi/Hdmi Playback Device , Dubbing/Mixing Room - Hardware And Software Thunderbolt 3 Cable (6.6, 40 Gb/S, Active) , Dubbing/Mixing Room - Hardware And Software Usb-C Digital Av Multiport Adapter (1 For Each System) , Dubbing/Mixing Room - Hardware And Software Usb C Hub 10Gbps 6-In-1 Multiport Adapter With 4K@60Hz Hdmi, Type A& C 3.2 Data Ports, 100W Pd For Mac , Dubbing/Mixing Room - Hardware And Software Tt0080831/ Netgear Av Line M4250-12M2Xf 12X2.5G And 2Xsfp+ Managed Switch , Dubbing/Mixing Room - Hardware And Software Izotope Rx 11 Standard , Dubbing/Mixing Room - Hardware And Software Mcdsp Sa2 Dialog Processor , Dubbing/Mixing Room - Hardware And Software Waves Diamond Bundle , Dubbing/Mixing Room - Hardware And Software Fab Filter Mixing Bundle , Dubbing/Mixing Room - Hardware And Software Audio Design Desk Subscription (2 Years) , Dubbing/Mixing Room - Hardware And Software Nugen Loudness Toolkit-2 , Dubbing/Mixing Room - Hardware And Software Sis Edicue , Dubbing/Mixing Room -Mics And Speakers Neumann Ma 1 Monitor Alignment Microphone And Calibration System , Dubbing/Mixing Room -Mics And Speakers Multi-Channel Extension For Neumann Ma 1 System Software , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 150 Dsp Powered Studio Monitor , Dubbing/Mixing Room -Mics And Speakers Height Adjustable Stands For Neumann Kh 150 , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 120 Ii Dsp Powered Studio Monitor (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Lh 32 Wall Mounts With Pan And Tilt (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 870 Ii Dsp Dual 10 Studio Subwoofer , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 310 3-Way Reference Studio Monitors Pair (Left And Right) , Dubbing/Mixing Room -Mics And Speakers Kali Lp 6 (Talk Back Speaker Pair For Recording Booth) , Dubbing/Mixing Room -Mics And Speakers Sennheiser Hd 200 Pro Closed-Back Studio Headphones , Dubbing/Mixing Room -Mics And Speakers Neumann Tlm 103 Stereo Set- Nickel (2 X Tlm 103 Ni + Ea1 In Aluminium Case) , Dubbing/Mixing Room -Mics And Speakers Sennheiser E945 Supercardioid Dynamic Vocal Microphone , Dubbing/Mixing Room -Mics And Speakers Rs-719 Heavy Duty Microphone Boom Stand , Dubbing/Mixing Room -Mics And Speakers Rs-521 Medium Weight Notepad/Lyric Stand , Dubbing/Mixing Room -Mics And Speakers Presonus Hp4 Headphone Annual Periodical Maintenance , Dubbing/Mixing Room -Mics And Speakers Promise Pegasus R4 16 Tb Raid With 3 Years Warranty , Dubbing/Mixing Room -Mics And Speakers Rs T3 Pop Shield , Dubbing/Mixing Room -Mics And Speakers 4-Port Professional Hdmi 4K Automatic Video Switch With Fast Switching , Dubbing/Mixing Room -Mics And Speakers Audio Cables And Connectors (Set) And Testing And Calibration , Dubbing/Mixing Room -Mics And Speakers Audio Rack - Black Color With 7 Pairs L Angle With Screws & Nuts & 15 Amps Power Supply With Side Panel And Heavy Duty Wheels , Dubbing/Mixing Room -Mics And Speakers Active Optical Hdmi Cable 25M , Dubbing/Mixing Room -Mics And Speakers Heavy Duty Cat6 Cable 25M , Dubbing/Mixing Room -Mics And Speakers Usb 2.0 Extender Over Cat5E/Cat6 Cable (Rj45) - Up To 165Ft (50M) - High Speed Usb Port Extender Adapter Kit - Powered , Edit Suite- Hardware And Software Pro Tools Studio Annual Paid Annual Subscription Edu , Edit Suite- Hardware And Software Pace Ilok 3 Usb-C Type , Edit Suite- Hardware And Software Neumann Mt 48 Usb-C Audio Interface , Edit Suite- Hardware And Software Neumann Ndh 20 , Edit Suite- Hardware And Software Neumann Kh 80 Dsp Powered Studio Monitor , Edit Suite- Hardware And Software Apple Mac Mini Apple M4 Chip With 10‑Core Cpu, 10‑Core Gpu, 16‑Core Neural Engine, 32Gb Unified Memory, 512Gb Ssd Storage , Edit Suite- Hardware And Software Applecare+ For Mac Mini (M4) , Edit Suite- Hardware And Software Sonnet Rackmac Mini (2024+) - 2U Enclosure To Mount And Secure Up To Three Mac Minis In A Standard 19-Inch Rack , Edit Suite- Hardware And Software Logic Pro - Professional Music Production , Edit Suite- Hardware And Software Neumann Rime Immersive Binaural Monitoring Plug-In , Edit Suite- Hardware And Software Waves Diamond Bundle , Edit Suite- Hardware And Software Lacie 4 Tb External Hdd Thunderbolt Connected , Edit Suite- Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Edit Suite- Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Inter Connection And Storage Equipment Requirements , Storage Centralized Parking Storage For All Departments: Eonstor Gs 3000 G3 3U/16Bay,Cloud-Integrated Unified Storage, Supports Nas, San, Object Protocol And Cloud Gateway, Dual Redundant Controller Subsystem Including 4X12Gb/S Sas Exp. Ports, 4X25Gbe Ports(Sfp28) +4X Host Board Slots,4X16Gb Memory, 2X(Psu+ Fan Module), 2X(Supercap. + Flash Module), 16Xdrive Trays And 1Xrackmount Kit 32X 3.5 Hdd, Sas 12Gb/S, 22Tb, 7200Rpm 3U/16Bay Dual Redundant Controller Expansion Enclosure Including 4X 12Gb Sas Ports, 2X(Psu+Fan Module), 16Xgs Drive Trays, 2X 12G To 12G Sas Cable For Storage Or Expansion Enclosure With 12G Interface And 1Xrackmount Kit 4X 10G Base-Sr Sfp+ Transceiver, Lc, Multi-Mode 3 Years Standard Warranty , Storage Animation Department Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Storage Digital Intermediate Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Interconnection Dell Switch S4148T-On Dell Switch S4148T-On, 1U, 48 X 10Gbase-T, 4 X Qsfp28, 2 X Qsfp+, Io To Psu, 2Xpsu Dell Networking, Qsa Adapter, Qsfp+/Qsfp28 To Sfp/Sfp+/Sfp28 For Select Optics Only (Total-4Nos) Dell Networking, Transceiver, Sfp+, 10Gbe, Sr, 850Nm Wavelength (Total- 4Nos) Dell Networking Cable 100Gbe, Qsfp28 To Qsfp28, Passive Copper Direct Attach Cable, 1 Meter (Total-4Nos) Dell Networking Cable, Om4 Lc/Lc Fiber Cable, (Optics Required), 10 Meter (Total-4Nos) 5 Yrs Pro Support Nbd. , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Cinematography Requirements , Category A: Cameras & Lenses A1. Photography Kit- 1St Year Camera Body- 1St Year Sony A7R5 Body • 61Mp Full-Frame Exmor R Bsi Cmos Sensor • Bionz Xr & Ai Processing Unit • Ai-Based Real-Time Tracking Af System • 8K 24P, 4K 60P, Fhd 120P 10-Bit Video • 4K 16-Bit Raw Output; S-Log3/S-Cinetone • 9.44M-Dot Evf With 120 Fps Refresh Rate • 3.2 4-Axis Multi-Angle Touchscreen Lcd • 10 Fps Shooting With Af/Ae Tracking • 8-Stop 5-Axis Image Stabilization • Dual Cfexpress Type A/Sd Card Slots , Lcd Guard For Sony A7R5 Lcd Panel Guard , Prime Lens 1- 50Mm Sigma 50Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format, Aperture Range: F/1.4 To F/16 • One Molded Glass Aspherical Element • Three Special Low Dispersion Elements • Super Multi-Layer Coating • Floating System & Large Diameter Design • Hyper Sonic Af Motor • Rounded Nine-Blade Diaphragm • Thermally Stable Composite Material • Brass Bayonet Mount • Compatible With Sigma Usb Dock , Uv Filter For Sigma 50Mm Lens Meco 72Mm Uv Filter , Prime Lens 2 35 Mm Sigma 35Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Design , Uv Filter Sigma 35Mm F/1.4 Lens Meco 67Mm Uv Filter , Prime Lens 3 85 Mm Sigma 85Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 85Mm F/1.4 Lens Meco 77Mm Uv Filter , Wide Lens 14Mm Sigma 14Mm F1.8 (E- Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Zoom Lens 1 24-70Mm Sigma 24-70Mm F 2.8 Dg Dn I (E- Mount) Or Equivalent • Full-Frame | F/2.8 To F/22 • Fast & Lightweight Wide-To-Tele Zoom • Hla Autofocus • 6.7 Minimum Focusing Distance • Aperture Ring With Click & Lock Switches • Fld, Sld & Aspherical Elements • Nano Porous & Super Multilayer Coatings • Dust & Splash Resistant , Uv Filter Sigma 24-70Mm Lens Meco 82Mm Uv Filter , Zoom Lens 2 70-200Mm Sigma 70-200Mm F 2.8Mm Dg Dn Os Sport Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Uv Filter Sigma 70-200Mm Lens Meco 82Mm Uv Filter , Telephoto Lens 150-600Mm Sigma 150-600Mm F 5-6.3 Dg Dn Os Sport Or Equivalent • Ef-Mount Lens/Full-Frame Format • Aperture Range: F/5 To F/22 • Two Fld Elements, Three Sld Elements • Super Multi-Layer Coating • Hyper Sonic Motor Af System • Os Image Stabilization • Fixed, Rotating Tripod Collar • Rounded 9-Blade Diaphragm , Uv Filter Sigma 150-600Mm Lens Meco 95Mm Uv Filter , Macro Lens 105Mm Sigma 105Mm F 2.8 Dg Dn Macro Art Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/2.8 To F/22 • One Sld Element • Super Multi-Layer Coating • 1:1 Magnification, 11.6″ Min. Focus • Hyper-Sonic Motor Af System • Custom Afl Button, Focus Limiter Switch • Physical Aperture Ring; De-Click Switch • Rounded 9-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 105Mm F/2.8 Lens Meco 105Mm Uv Filter , Battery Sony Fz100 Battery Or Equivalent ( A7R5 & Fx3A) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 Vdc / 2280 Mah (16.4 Wh) • Infolithium Feature, Dimensions: Approx. 51.7 × 38.7 × 22.7 Mm (W × H × D) • Weight: Approx. 83 G (3 Ozcompatibility: Supports Dozens Of Sony Cameras Including: O Alpha Series: A1, A1 Ii, A9, A9 Ii, A9 Iii, A7 Iii, A7R Iii, A7R Iv, A7 Iv, A7R V, A7S Iii, A7C, A7 C Ii, A7Cr, A6600, A6700 Cinema/V-Logging: Ilme-Fx3, Zv-E1, Zv-E10 Ii , Battery Charger Sony Dual Charger Bc-Zd1 (A7R5) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 V / 2280 Mah (16.4 Wh) • Infolithium Support: Displays Remaining Battery Level On Camera Lcd • Compatibility: Sony Alpha Series (E.G., A1 Ii, A9, A7R Iv, A7 Iv, A6600), Zv Series (Zv-E1, Zv-E10 Ii) • Dimensions: Approx. 38.7 × 22.7 × 51.7 Mm (W × H × D) • Weight: Approx. 83 G (3.0 Oz) • Durability & Safety: Built-In Protection Circuitry To Prevent Overcharging/Overheating (Sony Oem) , Category A2. Video Kit Camera Body-1 (2 Year Continuity Project) Sony Fx6 • 4K Full-Frame 10.2Mp Cmos Exmor R Sensor • Dci 4K60P | Uhd 4K120 | 1080P240 • 15+ Stops Of Dynamic Range In S-Log 3 Electrical Installation • 1.3X And 2.0X Anamorphic De-Squeeze • Compact Form Weighs Less Than 2 Lb • Phase Detection Af/Face Tracking/Eye Af • Base 800-12,800 Iso / 320-409,600 Max • S-Cinetone, S-Log3, Hlg Modes • 10-Bit 4:2:2 Xavc-I/16-Bit Raw Output • Dual Cfexpress Type A/Sdxc Card Slots , Camera Body-2 (3Rd Year Song Project) Sony Fx3A • 12.1Mp Full-Frame Cmos Exmor R Sensor • Uhd 4K Up To 120 | 1080P Up To 240 • Compact Form For Cage-Free Operation • 10-Bit 4:2:2 Xavc S-I,16-Bit Raw Output • S-Cinetone/S-Log3/Hlg, 15+ Stops Dr • Detachable 2 X Xlr/Trs Adapter Handle • Phase Detection Af/Face Tracking/Eye Af • 80 To 409,600 Expanded Iso Range • Dual Cfexpress Type A/Sdxc Card Slots , Battery Sony Fz100 Battery , Panel Guard For Sony Fx3A Lcd Panel Guard , Lens Kit 18Mm, 24Mm, 35Mm, 50Mm, 85Mm, And 105Mm (2Nd And 3Rd Year) Dzo Film, Vespid Ii Prime 6-Lens Set Includes 18Mm,24Mm,35Mm,50Mm,85Mm And 105Mm • Full Frame/Vv | T1.9 To T22 Aperture • 18, 24, 35, 50, 85, And 105Mm Primes • Aspherical Element, Reduced Aberrations • 0.8 Mod Gears, 300° Focus Rotation • Cooke /I Technology Metadata • 80Mm Front Outside Diameter • Compact, Lightweight Design • Less Reflective, More Tactile Surface • Color Matched, Common Gearing And Length • Minimal Breathing And Distortion , Gimbal (3Rd Year Song Project) Rs4 Pro Combo • Lightweight Design With 10 Lb Payload • Combo With Focus Pro Motor • Oled Touchscreen With Auto Lock • 2Nd Gen Native Vertical Shooting • Automated Axis Locks • Joystick Or Bluetooth Mode Switching • Supports Wireless Transmitter, Lidar • Teflon-Coated Axes, Activetrack Pro • 13-Hour Operation Time , Battery Sony Bp-U70 Lithium Ion Battery- (Fx6) • Battery Type: Professional Lithium-Ion Battery (Bp-U Series) • Capacity: 72 Wh • Output Voltage: Approximately 14.4 V Dc Nominal (16.4 V Max) • Charging Time: Approximately 150 Minutes Using Sony Bc-U1A/U2A Charger • Compatibility: Select Sony Professional Camcorders Including Pxw-Fs7, Fx6,.. • Dimensions: 41.5 × 84.5 × 69.7 Mm (1.63 × 3.32 × 2.74 In) Weight: Approximately 450 G (15.9 Oz) • Operating Conditions: Discharge: -20 °C To +45 °C (-4 °F To +113 °F); Charge: 0 °C To +40 °C (32 °F To +104 °F) , Battery Charger Sony Dual Battery Charger Bc-U2A Batteries (Fx6) • Battery Compatibility: Supports Sony Bp-U90, Bp- U60, Bp-U60T, And Bp-U30 Lithium-Ion Batteries. • Charging Capacity: Simultaneously Charges Two Batteries, Optimizing Workflow And Reducing Downtime. • Charge Times: Bp-U90: Approximately 190 Minutes. • Ac Input: 100-240 Vac, 50/60 Hz, Suitable For Global Use. • Dc Output: 12 Vdc Via Integrated Cable, Providing 12 V Dc Power Output While Charging One Battery. • Power Output: 12 Vdc At 3 A (36 W) Via Barrel Connector. • Dimensions: 7.0 × 5.4 × 2.1 Inches (177 × 137 × 53.2 Mm). • Weight: 1.4 Lb (620 G). • Operating Temperature: 32 To 113°F (0 To 45°C). • Certifications: Compliant With Iec62368-1 Safety Standard. , Category B: Photography Lights Flash Light 1 Godox V1 Pro S Or Equivalent • Compatible With Sony Adi / P-Ttl • Output: 76Ws • Auto Zoom Control, Zoom Range: 28-105Mm • 2.4 Ghz X Wireless Radio System • Built-In Led Modeling Lamp • Tilts -7 To 120°, Rotates 330° • Round Head, Optional Magnetic Modifiers • 1.5 Sec Recycle Time, Hss Support • Includes Detachable Sub-Flash , Studio Light 1 Godox Ad 600 Pro Or Equivalent • Built-In 2.4 Ghz Wireless X System • Compatible With Most Ttl Systems • 600Ws, 1/256 To 1/1 Power Output • Lithium-Ion Battery Powered • Up To 360 Full-Power Flashes • Flash Duration: 1/220 To 1/10,100 Sec • 1/8000 Sec High-Speed Sync • 0.01-0.9 Sec Recycling Time • 38W Modeling Lamp • Stable Color Temperature Mode , Studio Light 2 Godox Qt 600 Iii Or Equivalent • 600 Ws, 5600K Color Temperature • 0.01-0.9 Sec Recycling • Flash Duration Hss: 1/26,100 Sec • Built-In Wireless X System • 32 Channels, 16 Groups • Optional X1, X2 & Xpro Transmitter • 1/256 To 1/1 Power Range • 40W Led Modeling Lamp , Softbox Octa Softbox Or Equivalent Jenie Beauty Box 105Cm , Light Stand Harison Heavy Light Stand Harison Heavy Light Stand (Set Of 2) , Strip Box Godox Strip Box 35X160 , Beauty Dish Godox W 550 Silver Eauty Dish With Grid Godox Beauty Dish W550 Sliver With Grid (Set Reflector 1 + Grid 1) , Snoot Godox Snoot , Batteries Eneloop 2000Mah Aa Rechargable Batteries (Set Of 4) , Charger Panasonic Bk 3Hcce Aa Charger , Trigger Godox It 30 Trigger With Flash For Sony Works With X Wireless Radio System Compatible With Sony Adi / P-Ttl Frequency: 2.4 Ghz Range: 328 32 Channels; 99 Ids High-Speed, 1St & 2Nd Curtain Sync Runs On Internal Rechargeable Battery Touchscreen Interface Compact & Portable Design Includes Usb-C Cable & Carry Bag , Category C: Camera Accessories (2Nd And 3Rd Year)Tripod-1 Tripod Manfrotto Mt055-X Pro 3 Or Equivalent • Versatile 3-Section Aluminum Tripod • Spreads To Just 3.5 Above The Ground • 63 Max Height • 23.2 Folded Length • Photo/Video Fluid Tripod Head • 15.4 Lb Load Capacity • All-Direction Photo Mode • Pan-And-Tilt Video Mode • Friction Control , Tripod-2 E Image 7080H • Fluid Head With Bowl Size 75Mm. • Plate With Both 1 /4And 3/8Screws , Memory Card Cf Express Type A 240Gb Or Equivalent (A7R5) & Fx6 , Memory Card Angelbird 1Tb Cf Express Type B Or Equivalent (Burano) , Memory Card Sony 480Gb Tough Card Cf Express Type A , Card Reader 1 Sony Mrw-G3 Cf E Type A Card Reader , Card Reader 2 Sony Mrw-G1 Type B Card Reader , Camera Bag Vanguard Veo 49Bf Camera Bag , Hard Case Camera Hard Case (Pelican Type) (Fx6 & Burano) Explore 7635 Hlb Hard Case For Fx6 & Burano , Camera Cage 1 Small Rig Cage For Sony A7R5 Or Equivalent • Formfitting Camera Cage • 1/4-20 & 3/8-16 Accessory Threads • Maintains Access To Cameras Hot Shoe • Arri-Style Locating Handle Included • Built-In Shoe Mounts, Anti-Twist Design • Threads To Mount Optional Accessories • Durable Aluminum Construction , Camera Cage 2 Small Rig Cage For Sony Fx6 Or Equivalent • Camera Top & Side Plates • Quick Release Baseplate • V-Mount Plate With D-Tap Power Cable • Horizontal & Vertical Mounting • 1/4-20 & 3/8-16 Accessory Threads • 3/8-16 Anti-Twist Threads • Durable Aluminum Construction • Baseplate With Folding V-Lock Plate • 15Mm Rod Clamps & 2 X 15Mm Rods , Mattee Box Mattee Box (Fx6 ) • Compact Matte Box Weighing Only 3.8 Oz • Carbon Fiber Box And Top Flag • Includes 4 X 5.65 Filter Tray • Includes 67/72/77/82-95Mm Adapter Rings • Works With Circular Filters Up To 92.5Mm • 2.2 Lb Maximum Load Capacity , Filters H&Y Nd Filters (0.3,0.6 & 0.9) & Uv Filters (Complete Set) • 0.5 To 3.0 Optical Density • Multicoating & Resistance Coating • Schott B270 Optical Glass • Fits 58-77Mm Lens Filter Threads • High-Grade 6063 Aluminum Construction • Size-Adjustable Adapter Ring • Darkens Entire Image Area • Twist To Attach In Seconds , Filters Polariser Filter (Fx6 & Burano) • Minimize Reflections And Glare • Reduces Haze And Blue Cast In Landscapes • Enhances Color And Tonal Saturation • Colorcore Water White Glass , Field Monitor Atomos Shinobi 7 4K Hdmi/Sdi Monitor • 7 1920 X 1200 Touchscreen Display • 4K60 Hdmi 2.0 In/Out, 2K60 3G-Sdi In/Out • 2200 Cd/M² Brightness • Hdmi/Sdi Cross Conversion • 2.5Mm Camera Control Port For Z Cam E2 • Dual Sony L-Series Battery Slots • Atomos; Atomhdr & 3D Lut Support • 10-Stop Dynamic Range • Supports A Variety Of Log Formats , Measuring Laser Distance Meter , Focus Chart , Colour Checker Calibrite Colorchecker Passport Video 2 (Ccppv2) , Cleaning Kit Lens Cleaning Kit (Professional) , Cables 1 Mtr Cable Hdmi To Hdmi , Cables 0.5 Mtr Cable Sdi To Sdi , Cables 5 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Hdmi To Hdmi , Cables 15 Mtr Cable Hdmi To Hdmi , Category D: Cine-Lineup Cinema Camera (2Nd Year Misc-En & Scene Project) Sony Burano 8K Digital Motion • Compact, Highly Mobile Design • Full-Frame Cmos 8.6K Sensor • 16 Stops Of Dynamic Range • In-Body Image Stabilization|E & Pl Mount • Dual-Base 800/3200 Iso Range • Electronically Variable 0.6-21Nd Filter • Phase Detection Af | Face/Eye Tracking • Full Frame & Super 35 Sensor Modes • Supports Multiple Frame Rates & Codecs • Dual Cfexpress Type B Card Slots , Monitor/ Recorder Shogun Ultra 7 & Recorder • Atomos 11, 12G-Sdi/Hdmi Conversion • 7 1920 X 1080 Touchscreen • Records Up To 8K Apple Prores Raw • Prores Raw + H.265 Dual Recording • Airglu Rf Wireless Sync, Gige, 6E Wi-Fi • 2000 Cd/M² Brightness • Arri/Canon/Red/Sony Camera Sdi Support • Avid Dnx Quicktime • Atomos Remoteview Via Subscription • Optional Ndi 4K Tx Pro Mode 1-Off , Focus System Tilta Nucleus M(Dual Motor) • 1000 Wireless Range • Two Lens Drive Motors • Motors Feature Integrated Receivers • 0.8 Mod Drive Gears • Focus, Iris, Zoom Hand Unit • Motors Daisy-Chain For Power • Right Handgrip With Focus Control • Left Handgrip With Iris And Zoom Control • Hard-Shell Waterproof Case Included , Memory Card Lexar 512Gb Cf Express Type B Card Diamond Series Or Equivalent , Battery Newell V Mount Battery (290 Watts) , Charger Newell V Mount Dual Charger , Lens Kit 8,24,35,50,75, 100Mm Zeiss Nano Prime 6 Lens Kit(18,24,35,50,75,1 00Mm) Set • 18, 24, 35, 50, 75, And 100Mm Lenses • All Lenses Cover Full-Frame Format • T1.5 To T16 Aperture Range • 12-Blade Rounded Iris • Native Lens Data Communication • Zeiss Extended Data • Lens Scale Marked In Feet • Includes Transport Case , 10 &14Mm Laowa Lenses Pl Mount (12Mm Pl Mount Lens) • Full Frame & Vv | T2.6 To T22 Aperture • Zero-D Design, Low-Distortion Optics • 117.8° Fov, 15-Blade Aperture • 16 Elements In 10 Groups • 7.9 Minimum Focusing Distance • 77Mm Filter Thread, 80Mm Front Diameter , Zoom Lens 70-200Mm Zeiss 70-200Mm Cz.2 Lens , Tripod Occnnor 1040 • Tripod: Flowtech 100 Carbon Fiber • Payload Capacity: Up To 45 Lb (20.4 Kg) • Counterbalance: Sinusoidal, Continuously Adjustable • Pan/Tilt Drag: Independent, 9+0 Positions • Tilt Range: +90° To -90° • Tripod Max Height: 60 (152.4 Cm) • Leg Sections: 3, Quick-Release Locks • Floor Spreader: Included • Handle: Pan Handle Included, Attachable Both Sides • Weight: Approx. 12.5 Kg (27.5 Lb) , Camera Cage Tilta Camera Cage For Sony Burano Advanced Kit • Modular Cage For Sony Burano • 15Mm Lws Baseplate, Side Plates • Top Plate, Top Handle, Monitor Mount • Hdmi Cable Clamp, Wi-Fi Tx Bracket • Multiple 1/4-20 & 3/8-16 Threads • Qd Sockets, Shoe Mount, Nato Rails • Side Rosette, 15Mm Rod For Monitor Mount • Aluminum & Stainless Steel Construction , Evf Bracket Rotatable Evf Bracket For Sony Burano Or Equivalent , Tool Kit Tilta Multi Functional Mini Tool Kit • Multi-Functional Mini Tool Kit • Includes 2.5Mm, 3Mm, 4Mm, 3/16 Allen Keys • Flathead & Phillips #2 Screwdrivers, T10 Torx Driver • Aluminum Alloy Frame With Stainless Steel Tools • 3/8-16 And 1/4-20 Threaded Mounts • Compact And Lightweight Design • Integrated Strap Loop For Easy Carry • Color: Titanium Gray • Compatible With Tilta Camera Cages & Support Systems • Portable For Assembly, Disassembly, And On-Set Use , Matte Box Tilta 4X5.6 Carbon Fiber Matte Box Or Equivalent , Adaptor 1 Metabones Pl To E Mount Adaptor , Dry Cabinet Andbon 300 Ltr Dry Cabinet , Light Meter 1 (Common) Sekonic Spectro Master C- 800 Light Meter • Measurement Range: 0.09-18,600 Fc (1-200,000 Lux) • Color Temperature Range: 1600-40,000K • Sensor: High-Resolution Cmos Sensor With 1Nm Increment • Ssi Support: Spectral Similarity Index For Light Matching • Display: 4.3 Color Touchscreen With 11 Display Modes • Cri/Tlci/Tm-30-15: Full Color Rendering Metrics • Flash Measurement: Selectable Shutter Speeds From 1-1/500 Sec • Power: Usb Rechargeable • Connectivity: Usb 2.0 Interface • Dimensions: 73 X 183 X 27 Mm • Weight: 230 G • Included: Carrying Case And Usb Cable , Light Meter 2 (Common) Sekonic Speed Master L858D-U Light Meter • Measuring System: Incident And Reflected Light Metering • Sensor: Spd Sensor • Measuring Range: -5 To 22.9 Ev (Iso 100) • Illuminance Range: 0.1 To 2,000,000 Lux • Iso Range: Iso 3 To Iso 13,107,200 • Shutter Speed Range: 30 Min To 1/80,000 Sec • Display: 2.7 Color Touchscreen Lcd • Flash Measurement: Flash Duration (1/40 To 1/55,500 Sec) • High-Speed Sync (Hss): Supported • Flash Analyzing Function: Yes • Spot Metering: 1° Spot Meter With Viewfinder • Rotating Lumisphere: 270° Rotation, Retractable • Radio Control Modules: Optional For Pocketwizard, Elinchrom/Phottix • Weather Resistance: All-Weather Design • Power: Rechargeable Battery • Dimensions: Approximately 73 X 183 X 27 Mm • Weight: Approximately 230 G , Cine Video Monitor Tv Logic Monitor (Professional Grade) • 1920 X 1080 Resolution Ips Lcd Screen • Composite, 3G-Sdi A/B, Hdmi & Dvi Inputs • Hlg, Pq & Pq2 Hdr Emulation Support • 1 X Composite & 1 X 3G-Sdi Output • 500 Cd/M² Brightness, 178° Viewing Angle • 3.5Mm Audio Headphone Output • Gpi & Ethernet Control • Waveform, Vectorscope, Audio Meter • Focus Assist, H/V Delay, Key Lock, Zoom • Tvlogic Color Calibration Utility & More , Category E: Studio Kit (Common ) Computer Apple Mac Studio M3 Ultra 28 Core Cpu •Apple M3 Ultra 28-Core Cpu •96Gb Unified Ram | 2Tb Ssd •60-Core Gpu | 32-Core Neural Engine •Uhs-Ii Sdxc Card Reader •Wi-Fi 6E (802.11Ax) | Bluetooth 5.3 •6 X Thunderbolt 5 •2 X Usb-A 3.2 Gen 1 | 1 X Hdmi 2.1 •1 X 10 Gigabit Ethernet Port •Macos , Software Final Cut Pro , Software Adobe Psd Annual Subsrciption , Accessories Apple Monitor 27Inch 4K Retina Display , Accessories Apple Keyboard , Accessories Apple Magic Mouse , Accessories Required Cables , Light Controlling Tablet Apple Ipad Pro •13 Ultra Retina Xdr Oled Touchscreen •2752 X 2064 Screen Resolution (264 Ppi) •Apple M4 9-Core Cpu •10-Core Gpu | 16-Core Neural Engine •512Gb Storage | 8Gb Ram •5G Lte | Wi-Fi 6E | Bluetooth 5.3 •Front & Rear 12Mp Ultra Wide Cameras •40 Gb/S Thunderbolt Connectivity •Supports Apple Pencil Pro•Ipados , Display X Lg C3/G3 Oled 65 •Display Type: Qned (Quantum Dot Nanocell Withminiled) •Screen Size: 164 Cm (65 Inches)•Resolution: 3840 X 2160 Pixels (4K Ultra Hd) •Processor: Α7 Ai Processor 4K Gen8 •Color Technology: Dynamic Qned Color With 100%Dci-P3 Coverage •Local Dimming: Advanced Local Dimming Forenhanced Contrast •Hdr Support: Hdr10, Hlg, Dolby Vision •Audio Output: 20W Rms •Audio Technologies: Ai Sound Pro (9.1.2 Channel),Dolby Atmos •Operating System: Webos 2025 With Ai Features •Remote Control: Ai Magic Remote With Ms Copilotintegration •Connectivity: Wi-Fi, Bluetooth, Hdmi, Usb, Ethernet •Voice Assistant: Built-In Google Assistant, Alexasupport •Mounting: Vesa Compatible (300 X 300 Mm) •Dimensions (W X H X D): 1456 X 840 X 29.7 Mm •Weight: 22.5 Kg , Lg 9.1.5 Sound Bar S95Tr (Latest Model) Sound Bar: • Channels & Power: 9.1.5 Configuration With 810 W Total Output And 17 Built-In Speakers •Immersive Audio: Supports Dolby Atmos, Dts:X, Andtriple- Level Spatial Sound For A Cinematic Surroundexperience •Smart Integration: Ai Room Calibration Pro, Woworchestra & Wowcast Enable Seamless Integrationwith Lg Tvs And Wireless Pairing •Connectivity: Includes Hdmi Earc, Hdmi 2.1 Input,Optical, Bluetooth 5.1, Wi-Fi, Usb, Plus Support Forchromecast, Airplay 2, Alexa, And Google Assistant •Setup: Simple Installation Via Power And Single Hdmiconnection With Wireless Rears And Sub; Ideal Formedium-Sized Rooms •Design: Sleek And Low-Profile, Approximately 49.2 ×2.5 × 5.3 Inches (Soundbar); Space-Efficient Setup. , Projector 4K Projector With Screen •Display Technology: 0.65 Dlp •Resolution: 3840 X 2160 Pixels (4K Uhd) •Brightness: 2200 Ansi Lumens •Contrast Ratio: 600,000:1 •Color Gamut: 84% Dci-P3 •Throw Ratio: 0.69-0.83:1 •Zoom: 1.2X Manual Zoom•Focus: Manual •Input Lag: 4.16 Ms (1080P @240Hz) •Hdr Support: Hdr10, Hlg •Audio Output: 5W X 2 Speakers •Audio Features: Earc, Dolby Atmos Passthrough •Operating System: Android Tv (Via Qs02 Dongle) •Streaming Support: Netflix, Youtube, Prime Video,Disney+, Hbo Max, Apple Tv+, Spotify •Connectivity: 2X Hdmi 2.0B, Usb Type-A, Rs232,Audio Out (3.5Mm Mini Jack) •Wireless Features: Wi-Fi 6, Bluetooth 5.0, Googlecast, Apple Airplay •Dimensions: 11 Cm X 30 Cm X 25 Cm •Weight: 3.1 Kg •Power Consumption: 275W (Max), 0.5W (Standby) , Movable Storage 10Tb Desktop External Hdd - Usb 3.0 For Windows And Mac , Ups 1500Va Ups , Computer Speaker 2.1 2.1 Audio Computer Output , Mega Phone Ahuja Bta 550 Wireless Bluetooth Portable 30 Watt Pa • Power Output: 30W Rms • Speaker Configuration: Single 8 Full-Range Dual-Cone Speaker With Tweeter • Microphone Inputs: Two Wired Mic Inputs (4Mv/4.7Kω), One Wireless Mic Input • Auxiliary Input: One Guitar (Aux) Input (100Mv/47Kω) • Tone Controls: Active Bass And Treble Adjustments • Digital Effects: Built-In Digital Echo • Playback Features: Mp3 Player With Bluetooth, Usb, Sd/Mmc Card Support, And Recording Capability • Remote Control: Included For Convenient Operation • Power Sources: Ac Mains, External 12V Dc, Or Built-In 11.1V 2200Mah Rechargeable Li-Ion Battery • Battery Life: Approximately 4 Hours On Battery Power • Construction: Plastic Moulded Cabinet With Trolley System For Portability • With Microphone , Safety Storage Solid Safety Storage To Store Camera With Lock Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) , Category F: Lighting Equipments , Portable Light Kit • Eight Lights With Charging Case • Output: 396 Lux At 3.3 Per Light • 2000-10,000K Cct; Rgb Color Control • 4.2 X 2.7 Panel; 2-Hour Runtime Battery • Cri 96 | Tlci 96 | Cqs 95 | Tm-30 Rf 94 • Onboard, Dmx/Rdm, Crmx & App Control • Tighter 45° Beam Angle • 0-100% Dimming, 15 Special Effects • 1/4-20 & Magnetic Mounting, Ip65-Rated • Includes Mounting Accessories & Cables , Cine Led Bulb Kit Aputure B7C Bulb Kit (8 Bulbs) • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Panel Light 1 Aputure Nova P600 C Panel Light • For Studio & Film/Tv Production Output: 17,520 Lux At 3.3 (5600K) • 2000 To 10,000K; Rgb Color Control • 31.6 X 18.96 Panel, Ac/Dc Operation • Cri 95 | Tlci 95 | Ss1 84 | Cqs 95 • On-Board, Dmx512, Bluetooth App Control • Active Fan Cooling • With Control Box, Yoke, Mounting Clamp • Dimming: 0-100°, Plus/Minus Green Adj. • 300+ Gel Presets, 19 Special Effect , Barn Door Aputure Barndoor For P 600 Light P600Rb4 Barn Door For Aputure P600C Or Equivalent , Soft Box Aputure Softbox P 600R23 • For Studio & Film/Tv Production • Output: 98,500 Lux At 3.3 W/ Reflector • 5600K Cct • Ac Or Battery Power • Onboard, Wireless, Dmx & App Control • Art-Net & Lumenradio • Cri 96 | Tlci 96 | Cqs 94 | Ssi 72 • Active Cooling, Weather-Resistant Design • Bowens S Accessory Mount • Includes Remote, Reflector & Rolling Bag , Cine Led Light Godox M 600R Light For Studio & Film/Tv Production Output: 136,000 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Onboard, Dmx, Crmx & App Control Art-Net & Sacn Ethernet Control Fan Cooled Bowens Mount Ip65 Rated Includes Control Box Includes Power Cable & Soft Case , Cine Light 1 Godox Tl120-K4 Light Four Lights & Remote Control For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case , Cine Light 2 Godox Tl 60-K2 Light Two Lights & Remote Control For Wireless Control From Up To 164 Output: 421 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Bag Remote Control & Carry Case , High Power Light 1 Godox Mg 120 Arc-Biannual Rate Contract Color Light For Photo, Video, Film & Tv Production 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , High Power Light 2 Godox Mg1200 R Light Compatible With Godox G-Mount Modifiers Green/Magenta Adjustments, 14 Effects Upgraded Optical Technology, Ip65 Rated 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , Storm Light 1 Godox Mg4 K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 640,000 Lux At 3.3 W/ Reflector 2800-10,000K Cct; Green/Magenta Shift Ac Power Onboard, Dmx, Crmx, Ethernet & App Improved Fan Cooling System Compatible With Godox G-Mount Modifiers Upgraded Optical Technology & Ip65 Rated 2.4 Diameter Light Source Emitter Includes Controller & Ac Power Cable , Storm Light 2 Godox Mg 6K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 1,025,000 Lux At 3.3 (5600K) 2800-10,000K Cct; Bi-Color Mode Powered Via Ac Cable & Power Controller Onboard, Dmx, Rdm & Bluetooth Control Cri 97 | Tlci 97 Advanced Air Cooling System G-Mount-Compatible & Includes Yoke Ip65-Rated For Dust & Water Protection , Light Mat 1 Aputure Infinimat 4 X 4 Light Mat • Type: Modular Rgbww Led Light Mat • Size: 4 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 1600W, Ac-Powered • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 800W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Mat 2 Aputure Infinimat 2 X 4 • Type: Modular Rgbww Led Light Mat • Size: 2 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 400W, Gold Mount • Power Options: Ac Or Gold Mount Battery • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 400W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Bar 1 Aputure Infinibar Pb 12 4 Light Kit • Output: 617 Lux At 3.3 (120º, 7500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • 8 X 45º Light Control Grids • Flight Case And 330W Power Adapter , Light Bar 2 Aputure Infinibar Pb6 4 Light • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Compact Light 1 Amaran F22C Light • For Studio & Film/Tv Production Output: 6420 Lux At 3.3 (5600K) 2500-7500K Cct; Hsi Color Control • 2 X 2 Mat; Ac/Dc Operation • Cri 95 | Tlci 98 | Cqs 96 • On-Board, Dmx, And Bluetooth Control • Passive Cooling For Silent Operation • 0-100% Dimming, 15 Lighting Effects • Multi-Voltage Ac, V-Mount Battery • Includes Softbox Frame, Diffusers & Grid , Compact Light 2 Godox La 300 R Light For Video Production & Vlogging Output: 94,700 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount, Black Housing Includes Reflector Includes Power Adapter , Compact Light 3 Godox La 150 R Light For Video Production & Vlogging 165W Fixture 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount Includes Reflector Includes Power Adapter , Panel Light 2 Godox Ldx 100 R Light For Video Production And Vlogging Output: 4620 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 18 X 16; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Panel Light 3 Godox Ldx 50 R Light For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Cine Light Kit Aputure Storm 80C- 3 Light Kit Or Equivalent For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Professiona L Light 1 Godox P 1200 R Hard P8 / Arri Sky Panel-X 21 Or Equivalent • Type: Modular Rgbacl Led Panel • Color Temperature Range: 1,500-20,000K • Color Accuracy: Cri ≥99, Tlci ≥93 • Light Output: 16,602 Lux At 3.3 (1M) • Panel Size: 2X1 (29.1 X 13.3 Inches) • Pixel Zones: 8 Independent Zones • Control Options: Wired (Dmx-512), Wireless (Bluetooth Via Lico App, Lumenradio) • Cooling: Passive/Active With Ip66 Rating • Power Supply: Integrated Psu; Daisy-Chainable With Other Skypanel X Units • Mounting: Tool-Less Frame With Quick-Lock System • Compatibility: All S60-C Accessories Via Optional Adapter • Included Accessories: X21 Dome, Manual Yoke, Mains Cable , Hard Light Godox P 1200 R Hard / X21 Hard Light For Arri Sky Panel Or Equivalent P8 X21 Hard Light For Arri Sky Panel Or Equivalent , High Power Light Godox P 1200 R Hard P 8 For Studio & Film/Tv Production Output: 129,200 Lux At 3.3 (5600K) 1800-10,000K Cct; Rgb Color Control 29.2 X 15.2 Panel | Ac Power Cri 96 | Tlci 98 Onboard, Dmx/Rdm, Crmx & App Control Improved Fan Cooling System Flicker-Free Operation Ip65-Rated Weather Resistance Includes Yoke & Ac Power Cable , Dido Lights Godox Ms 600R 2K / Dido Lights Light , Category G: Light Accessories Spotlight Mount 1 Godox Vsa-26 K Spotlight Attachment Projectionlight Kit , Spotlight Mount 2 Godox Vsa-36K Kit Spotlight Attachment Kit , Iris 18 X Godox Vsa-Id Spotlight Mount 36 , Gobo Kit Godox Vsa-Gs1 Gobo Kit , Fresnel 1 Godox Fls 5 Fresnel , Fresnel 2 Godox Fls 10 Fresnel , Barn Door Godox Lb-02 , Light Dome 1 Godox Qr-P 90 T Light Dome , Light Dome 2 Godox S 65 T Light Dome Mini , Light Dome 3 Godox Qr-P 150 T Light Dome , Light Dome Godox Cs 85D Lantern 120 , Light Dome Godox Gp 5 Light Dome , Lantern Godox Cs 85 D Lantern , Reflector Kit Reflector Kit (For 1200X & 1000C) Or Equivalent , Cf12 Fresnel Godox Fls 10 Fresnel , Spotlight Max 1 Godox Gp 36 K Spotlight , Spotlight Max 2 Spotlight Max 50 (For 1200X,1000C,Xt 26) Or Equivalent , Iris Max 18 Godox Gp-Id Iris , Gobo Kit Godox Gobo Kit Godox Gp-Gs1,2,3,4,5 , F14 Fresnel Godox Gf 14 Fresnel , Beam Kit Storm Parallel Beam 70 Kit With Flight Case Or Equivalent , Cf16 Fresnel Cf16 Fresnel With Flight Case Or Equivalent , Stand 1 Dearkol Mfe 5800 (Expandable Up To 17Ft Height & 62Kg Payload) Or Equivalent , Stand 2 Dearkol Mfd 6000 (Expandable Up To 20Ft And 82Kg Payload) Or Equivalent , Soft Box Godox P 1200 Rh Do Softbox , Mounting Rig Godox P 1200 Rh Ad Mounting Rig , Lights Dimmer 5K Dimmer , Skimmer Cloth 10X10 Skimmer Cloth , 12 X12 Skimmer Cloth , 10X10 Black Cloth , 12 X12 Black Cloth , 10X10 Green Cloth , 12 X12 Green Cloth , Backgroung For Photography , Safety Storage For Lights Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) Stainless Steel 0.8Mm, Thickness (Jindal Ss) , Category H: Light Grip Equipments C Stand Godox 270Cs Stand , Par Stand 1 Par Stand Double Height , Par Stand 2 Par Stand Triple Height Or Equivalent , Black Flags 1 4X4 Black Flags Or Equivalent , Black Flags 2 2X1 Black Flags Or Equivalent , Empty Frames 4X4 Empty Frames Or Equivalent , Boom Rods Boom Rods (Various Sizes) Or Equivalent Boom Rods : Stand Height 6Ft To 10Ft, Extension Rod 5 Ft To 10Ft. , Arm Rods Arm Rods (Various Sizes) Or Equivalent , L Rods L Rods (Various Sizes) Or Equivalent , Sand Bag Sand Bag (Professional Grade) Or Equivalent , Skimmer Frame 1 6X6 Skimmer Frames Or Equivalent , Skimmer Frame 2 10X10 Skimmer Frames Or Equivalent , Skimmer Frame 3 12X12 Skimmer Frames Or Equivalent , Grid 1 Honey Comb Grid 6X6 Or Equivalent , Grid 1 Honey Comb Grid 10X10 Or Equivalent , Grid 1 Honey Comb Grid 12X12 Or Equivalent , Loop Boards Loop Boards (Various Sizes) Or Equivalent Solid Wooden Loop Boards (Various Sizes) 20Mtrs 6Pin Socket 2Nos With Led Indicator And A Tripper-15 Nos; 10Mtrs Board With 6Pin Socket 4 Nos With Switch, Led Indicator And A Tripper- 10 Nos; And 20Mtrs Board 6Pin Socket 6Nos With Switch, Led Indicator And A Tripper-5 Nos. , Track System Track & Trolley Full Kit 40Feet Length Manuall 150 Bowl Height 100Kg Capacity With Head , Slider Slider 10Ft Full Kit Or Equivalent , Low Base Stands Low Base Stands , Stand For 100 Bowl Head , Stand For 150 Bowl Head , Cutter Stand , Grip Heads Grip Heads (Professional Grade) , Reflector Board Reflectors 4X4 Board , Low Board , Apple Box Apple Box Setup (Complete Set) Apple Box Setup 20X12X8, 20X12X4, 20X12X2 ,20X12X1 (Complete Set) , Stool Setup Stool Setup 1 Feet , Stool Setup Stool Setup 2 Feet , King Pole- Wall To Wall Mount King Pole (6Ft To 12Ft) , Light Clamps Light Clamps (Various Sizes) , Hydraulic Stand Hydraulic/Windup Stand , Category I: Television Production , Video Camera Sony Hx Z 200 Camera , Mixer Yamaha Mg10X Mixing Console Audio Mixer - Xlr Input/Output, Phono Jack, Level Meter , Recorder Zoom H8 Recorder , Tripod Small Rig Ad80 Carbon Tripod Model No:4163 , Mic And Accessories Sennheiser Lapal Microphone With Cable , Mic And Accessories Rode Boom Pole , Mic And Accessories Rode Ntg4 Mic , Mic And Accessories Rode Blimp , Cables Monitoring Head Phone, Video/Audio Cables And Connectors , Mac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 512Gb Ssd, 24Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours, Keyboard & Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Manpower Deployment , Cost For Deployment Of System Administrator For One (1) Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
48.
Water Resources and Irrigation #10799280 Price Bid
Tender For Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 15M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge.. All Kinds Of Soil. , Excavating Trenches Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M : All Kinds Of Soil. Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , Supplying And Filling In Plinth With Sand Under Floors Including, Watering, Ramming Consolidating And Dressing Complete. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Iii Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Ill) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 10. Centring And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights. 10. (I) Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. , 10. (Ii) Suspended Floors, Roofs, Landings, Balconies And Access Platform. , 10. (Iii) Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , 10. (Iv) Columns, Pillars, Piers, Abutments, Posts And Struts , 10. (Vi) Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide , 10. (Vii) Weather Shade, Chajjas, Corbels Etc., Including Edges. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo -Mechanically Treated Bars Of Grade Fe-500D Or More. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:4 (1 Cement : 4 Coarse Sand , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 (1 Cement :4 Coarse Sand) Ement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600X600 Mm , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Oarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sgm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To 1S: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete : 100X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete : 125 Mm , Providing And Fixing Is : 12817 Marked Stainless Steel Butt Hinges With Stainless Steel Screws Etc. Complete : 125X64x1.90 Mm , Providing And Fixing Aluminium Sliding Door Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc. Complete :250X16 Mm , 28. Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 28. (I) 150X10 Mm , 28. (Ii) 100X10 Mm , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Fixed Portion Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately).Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item) :With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On Both Sides. , Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations:(E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge:With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : In 75X75mm Deep Chase , Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1Mx1mx400micron, Finished With 12Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement Rounding The Edge Sand Making And Finishing The Outlet Complete. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion.(I) Single Socketed Pipes.110 Mm Diameter , 38. Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A Including Jointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mm Gap For Thermal Expansion. 38. (I) Coupler 110 Mm , 38. (Ii) Single Tee With Door 110X110x110 Mm , 38. (Iii) Bend 87.5° 110 Mm Bend , Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) And Making Good The Wall Etc. Complete 110 Mm , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank.Circular Tank , 43. Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge Internal Work - Exposed On Wall 43. (I) 15 Mm Nominal Outer Dia Pipes , (Ii) 20 Mm Nominal Outer Dia Pipes , (Iii) 25 Mm Nominal Outer Dia Pipes , 46. Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. Concealed Work, Including Cutting Chases And Making Good The Walls Etc. 46. (I) 15 Mm Nominal Outer Dia Pipes , 46. (Ii) 20 Mm Nominal Outer Dia Pipes , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :Range Of Three Urinal Basins With 10 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible 40 Mm Dia , Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms , Providing And Fixing Ptmt Shelf 440 Mm Long, 124 Mm Width And 36 Mm Height Of Approved Quality And Colour, Weighing Not Less Than 300 Gms , 56. Providing And Fixing Ptmt Shelf 440 Mm Long, 124 Mm Width And 36 Mm Height Of Approved Quality And Colour, Weighing Not Less Than 300 Gms 56. (I) 25 Mm Nominal Bore , 56. (Ii) 20 Mm Nominal Bore , 58. Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 58. (I) 15 Mm Nominal Bore , 58. (Ii) 20 Mm Nominal Bore , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 45 Cm Length 15 Mm Nominal Bore , 61. Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) 61. (I) 15 Mm Nominal Bore , 61. (Ii) 20 Mm Nominal Bore , 61. (Ii) 25 Mm Nominal Bore , Providing And Fixing Ptmt Stop Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 86Mm Long. Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt, Push Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 98Mm Long. Weighing Not Less Than 75 Gms. , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 : 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931. 15 Mm Nominal Bore , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15Mm Nominal Bore , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement : 6 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix 1:6 (1Cement: 6 Fine Sand). , 6 Mm Cement Plaster Of Mix : 1:3 (1 Cement: 3 Fine Sand) , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour :New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sqm. Mm F.R. L.S. Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet Suitable Size ;M.S. Box And Earthing The Point With 1.5 Sq.Mm Fr L.S. Pvc Insulated Copper Conductor Single Core Cable As Required (Group C). , 78. Wiring For Circuit/Sub Main Wiring Along With Earth Wire With The Following Sizes Of Fr L.S. Pvc Insulated Copper Conductor, Single Core Cable In Surface/Recessed Steel Conduit As Required. 78. A) 2X2.5 Sq.Mm + 1X2.5 Sq. Mm Earth Wire. , 78. B) 2X6 Sq. Mm + 1X6 Sq. Mm Earth Wire , Wiring For Light /Power Plug With 2X4 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit Along With 1 No. 4 Sq. Mm Fr Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Supplying And Fixing Metal Box Of 150Mm X75mmx60 Mm Deep (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Providing And Fixing 3 Pin 5/6 & 15/16 Amps Socket Outlet And 5/6 Amps Piano Type Switch, Connection, Painting Etc. As Required For Light Plugs To Be Used In Non Residential Building. , Earthing With G.I. Earth Pipe 4.5 Metre Long 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/Coke And Salt As Required. , 83. Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , 83. B) Single Pole & Neutral , Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. 200 Mm X 250 Mm X 60 Mm Deep , Supplying & Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts On Surface/Recess, Complete With Tinned Copper Bus Bar, Earth Bus Bar, Din Bar, Detachable Gland Plate, Interconnections, Phosphatized And Power Painted Including Earthing Etc. As Required (But Without Mcb/Rccb/Isolator) 12 Way, Double Door. , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cm/M/W) Minimum 6.00, Air Delivery Minimum 210 Cum/Min , 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , Providing And Laying Cement Concrete In Retaining Walls, Return Walls,Walls (Any Thickness) Including Attached Pilasters, Columns, Piers,Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets,Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering,Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Small Lintels Not Exceeding 1.5 M Clear Span, Moulding As In Cornices, Window Sills, String Courses, Bands, Copings, Bed Plates, Anchor Blocks And The Like , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Washed Stone Grit Plaster On Exterior Walls Height Upto 10Metre Above Ground Level,In Two Layers,Under Layer12mm Cement Plaster 1:4 (1 Cement : 4 Coarse Sand ), Furrowing The Under Layer With Scratching Tool,Applying Cement Slurry On The Under Layer @ 2 Kg Of Cement Per Square Metre, Toplayer 15Mm Cement Plaster 1: 1/2:2 (1Cement: 1/2 Coarse Sand : 2 Stone Chipping 10Mm Nominal Size), Inpanels With Groove All Around As Per Approved Pattern,Including Scrubbing And Washing The To Player With Brushes And Water To Expose The Stone Chippings,Complete As Per Specification And Direction Of Engineer-In- Charge (Payment For Providing Grooves Shall Be Made Separately). , Forming Groove Of Uniform Size In The Top Layer Of Washed Stone Grit Plaster As Per Approved Pattern Using Wooden Battens, Nailed To The Under Layer, Including Removal Of Wooden Battens, Repair To The Edges Of Panels And Finishing The Groove Complete As Per Specifications And Direction Of The Engineer-In-Charge :15 Mm Wide And 15 Mm Deep Groove , Providing And Fixing Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M), Having 50 Nos Rounds Per 6 Metre Length, Upto 3 M Height Of Wall With Existing Angle Iron Y Shaped Placed 2.4 M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape(R.B.T.) / Spring Core (2.5Mm Thick) Wire Of High Tensile Strength Of 165 Kg/ Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/ Metre (Cost Of M.S. Angle, Cement Concrete Blocks Shall Be Paid Separately) , Providing & Laying Of Selection No. 1 Doob Grass Turf With Earth 50Mm To 60Mm Thickness Of Existing Ground Prepared With Proper Level And Ramming With Required Tools Wooden And Than Rolling The Surface With Light Roller Make The Surface Smoothen And Light Watering The Same And Maintenance For 30 Days Or More Till The Grass Establish Properly, Asper Direction Of The Officer-In-Charge. , Supplying Of Earth In Rough Excavation, Banking Excavated Earth In Layers Not Exceeding 20 Cm In Depth, Breaking Clods, Watering, Rolling Each Layer With ½ Tonne Roller, Or Wooden Or Steel Rammers, And Rolling Every 3Rd And Top-Most Layer With Power Roller Of Minimum 8 Tonnes And Dressing Up, In Embankments For Roads, Flood Banks, Marginal Banks, And Guide Banks For Filling Up Ground Depresssion Lead Upto 15 Km And Lift Upto 1.50 M. , Supplying And Stacking Of Well Decayed Cattle Manure At Site Including Royalty And Carriage Upto 5 K.M. Lead Complete (Cattle Manure Measured In Stacks Will Reduced By 8% For Payment). , Filling Mixture Of Earth And Sludge Or Manure In The Desired Proportion In Trenches, Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading,Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , Supplying Installation, Testing And Commissioning Of Bulk Head/Ceiling Light Fitting Suitable For 10/12 Watt Led Complete With Bulb And Accessories Such As Glass, Wire Guard, Lamp Etc. Including Connection As Required (Make Surya, Baja, Wipro, Philips, Havells). , Supplying Installation Testing And Commissioning Of Energy Efficient Ceiling, /Wall/Guarder Mounting Prewired Fluorescent Tube Light Fitting Suitable 36/40 Watt Lamp. The Fitting Shall Be Completed With Electronic Ballast, Lamp & Holder Duty Wired Up Ready For 240 Volts, Single Phase, 50Hz Ac Supply Confirming To Is: 10322 As Per Quality Requirement. Fitting Shall Be Provided With All Accessories And Mounting Arrangement As Required, Including Connection With 1.5 Sqm. Mm Fr Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. (Make Surya, Bajaj, Havells, Philips Wipro) Or As Approved By The Engineer-In-Charge. , Supply Of 150 Led Luminaire For Flood Light With Warranty For Free Replacement 1 Year 140 To 270 Volts Ac At 50 Hz+/-2 Hz With Auto Cutt Off At Below 120V, Including All Wiring, Circuity, Switch & Installation (Make For Led Street Light Bajaj, Cropton, Orient Or Equivalent). , Providing, Fixing Erection And Testing Of 3G.I. Pole (Medium Class) Of 6 Mtr. Hight Having Base Plate Welded On Bottom Of Pipe Of Suitable Thickness With Foundation Including Excvation Shuttering And Cement Concrete Complete Etc As Required And As Per Direciton Of The Engineer-In-Charge At Site. , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications ,Duplex Maps D01 As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Combination Set 3 In 1,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Frp Wave Slide 2.1 Mtr., As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Toddler Swing, As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Standard Swing,,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Circular Swing,Simply Go Round,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Half Round Net,As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Std. See-Saw (Double),As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing And Fixing Play Equipments (Swings) At Sites As Per Specifications Spring Rider Jumboas Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing Fixing And Installation Of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make A Leg Curl & Extension Machine That Contains A Leg Extension/Curl Dual Action Section That Is Affixed To The Main Monolitic Curved Annual Rate Contract Tube Central Pillar Without Any Convex Sides Of 89Mm Od And Min Wall Thickness Of 3 Mm & Has A 8Mm Thick, 40Cm Gusset Support Using A One A.R.M Module ( Angular Resistance, Bearing Less Module ) That Works As Dual Action [Push And Pull / Extension & Contraction]. The Arm Must Be Bearing Less, Shock Less, Drop Less And Provide 0-30 Kg Resistance. The Seats Are Fixed To The Main Curved Central Pillar And Do Not Move Up And Down - [Are Immovable] To Ensure It Is Safe & Stable, Zero Drops And Support Disable People To Use The Product Without Risk Of Falling Or Slipping Off. All Fasteners To Be Of 304 Stainless, Torx Anti Vandal Fasteners, All Nuts Enclosed In Polyamide Anti Vandal Caps. The Seat Must Consist Of Pu Polysafe Cusions Seats. Finishing To Be Metalized / Plasma Zinc Injection + Dupont/Alexta Outdoor Use Color Powder Electrostatic Coating. All Complete Fixing Of Equipment In Foundation Is To Done As Per The Direction Of Engineer In Charge Or As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing Fixing And Installation Of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make Double Tai Chi Teflon Resistance Trainer. The Unit Must Consist Of 4 Wave Shaped Fan Blades Made Of High Grade Poly-Ethylene, With Rotate Free Grips & Without Any Holes Or Gaps To Prevent Entrapment. The Blades Are Attached To An Ergonomically Curved, Monolithic Large Annual Rate Contract Tube Center Pillar Without Convex Sides & Minimal Deformation To Provide A Pleasing, Mordern Aesthetic Look. The Wall Thickness Of The Main Curved Center Pillar Is Minimum 3 Mm & Has A 8Mm Thick, 40Cm Gusset Support. The Blades Are Connected To High Grade Teflon Resistance Maintainance Free Bearings. All Fasteners To Be Of 304 Stainless, Torx Anti Vandal Fasteners, All Nuts Enclosed In Polyamide Anti Vandal Caps. Finishing To Be Metalized / Plasma Zinc Injection + Dupont/Alexta Outdoor Use Color Powder Electrostatic Coating. All Complete Fixing Of Equipment In Foundation Is To Done As Per The Direction Of Engineer In Charge Or As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing Fixing And Installation Of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make Double Shoulder Press Station That Must Contain Of Two A.R.M Modules ( Angular Resistance, Bearingless Module) That Works As Dual Action [Push And Pull / Extension & Contraction] Connected To A Main Center Pillar Of Od 89Mm Of Min 3Mm Thickness. The A.R.M Must Be Bearingless, Shock Less, Drop Less And Provide 0-30 Kg Resistance. The Seats Are Fixed To The Main Post And Do Not Move Up And Down - [Seats Are Immovable] To Ensure It Is Safe & Stable, Zero Drops And Support Disabled People To Use The Product Without Risk Of Falling Or Slipping Off. Finishing To Be Metalized / Plasma Zinc Injection + Dupont/Alexta Outdoor Use Color Powder Electrostatic Coating. The Handles Are Of 3Mm Endu-Rubber With Aluminum Cap Locking Anti Vandal System. All Fasteners To Be Of 304 Stainless, Torx Anti Vandal Fasteners, All Nuts Enclosed In Polyamide Anti Vandal Caps. All Complete Fixing Of Equipment In Foundation Is To Done As Per The Direction Of Engineer In Charge Or As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing Fixing And Installation Of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make A Three Person Body Twister Station That Consists Of Three Swivel Stands That Rotates But With A Built In Safety Limitor That Meets International Safety Standards As The Arms And Shoulders Of The User Are Held Square In The Overhead Hold That Is Fixed To A Monolithic Large Annual Rate Contract Tube Center Pillar Without Convex Sides & Minimal Deformation Ergonomically Curved. The Center Pillar Has An Od Of 89 Mm, The Wall Thickness Is Min 3 Mm & Has A 8Mm Thick, 40Cm Gusset Support At Standard Height Of 1.4M. All Fasteners To Be Of 304 Stainless, Torx Anti Vandal Fasteners, All Nuts Enclosed In Polyamide Anti Vandal Caps. Finishing To Be Metalized / Plasma Zinc Injection + Dupont/Alexta Outdoor Use Color Powder Electrostatic Coating. All Complete Fixing Of Equipment In Foundation Is To Done As Per The Direction Of Engineer In Charge Or As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge , Providing Fixing And Installation Of Arihant /Kompon /Landscape /Koochie /Hugo / Grandslam Fitness Make A Foot Cycle That Has A Central Pin Which Connects The 2 Heavy Flywheels & Which Has 2 Main Bearings And In Addition Has A Teflon Resistance Bearing Which Locks The Pin And Creates Resistance To The Spin. The Central Pillar Is A Monolithic Large Annual Rate Contract Tube Without Convex Sides & Minimal Deformation Which Is Ergonomically Curved With An Od Of 89 Mm, The Wall Thickness Is Min 3 Mm & Has A 8Mm Thick, 40Cm Gusset Support At Standard Height Of 1.4M. All Fasteners To Be Of 304 Stainless, Torx Anti Vandal Fasteners, All Nuts Enclosed In Polyamide Anti Vandal Caps. Finishing To Be Metalized / Plasma Zinc Injection + Dupont/Alexta Outdoor Use Color Powder Electrostatic Coating. The Seat Must Consist Of Pu Polysafe Cushions Seats. All Complete Fixing Of Equipment In Foundation Is To Done As Per The Direction Of Engineer In Charge Or As Per Approved Drawing & Design Given By Manufacturer Including Earth Work, C:C Work Up To Plinth Level In 1:2:4 (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size) Of Required Size As Per Department / Manufacturers Specifications And Guidelines.Engineer In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
49.
Educational and Research Institute #10793316 Price Bid
Tender For Purchase / Procurement Of Equipment / Items Under Commercial Cultivation Of Elite Cricket Bat And Wicker Willows For Industrial Sector In Kashmir (Nabard) At Fof Benihama, Skuast-2 ASTM IMPACT TESTING MACHINE FOR WOOD 3 • Charpy Impact Test, V-notch (typically 45° angle, 2.54 mm deep), Pendulum hammer,• Impact velocity around 3.5 m/sNominal: 125 mm × 13 mm × 3 mm (standard size for plastics, adjustable for wood) 4 TREE RING STATION 5 • Cell count: The number of valid cells in the analysed region.• Area (Total, Average & Individual): Lumen area.• Length, Width & Length / Width ratio (Individual & average): 4 different methods to measure objects length and width. • Perimeter & Form Coefficient (Individual & average): Lumen perimeter and form coefficient (a numerical value which grade the leaf shape between circular (shortest perimeter for a given area) and filliform (longest perimeter for a given area).• Position: Lumens position in the image. • Interactive measurements to measure lumen and walls at specific places: Measures lumen & walls on paths trAaced interactively.• Manual cells/objects counter: Manually count cells/objects by clicking them.• Ring analysis: Morphological cells measurements on a ring basis (requires high resolution images of whole rings).• Color analysis: For lument & walls detection & Area quantification per color.• Camera Casing- Metal Alloy• Camera Dimension-60X60 X40 MM• Resolution (Max)- 2592X1944 Pixels• Power Supply-5V DC Via USB-2• Operating temp -10 deg.C to + 50deg.C• Operating Humidity 30 to 80% RH 6 ARTIFICIAL WEATHERING METER 7 • Outdoor temperature range: -40.0 °C to + 65.0 °C (-40 °F to +149 °F)• Indoor temperature range: 0 °C to + 50.0 °C (32 °F to +122 °F)• Humidity range: 10% to 99% (1% resolution)• Rain volume display: 0 - 9999mm (show OFL if outside range) Resolution : 0.3mm (if rain volume < 1000mm) ,1mm (if rain volume > 1000mm)• Wind speed: 0~100mph (show OFL if outside range)• Measuring range air pressure: 27.13inHg - 31.89inHgResolution : 0.01inHg• Alarm duration : 120 sec 8) • Transmission range up to 100m (330 feet) 9) • Power consumption: a) Receiver: 3 x AA alkaline batteries (not included) b) Sensor: 2 x AA alkaline batteries (not included)• Transmission frequency: 433MHz 8 WOOD MICRO-HAMMER 9 • To measure the sound velocity with the Micro Hammer it is necessary to enter two special screws on opposite sides of the tree. The attachment system with magnetic fixtures minimizes the damages caused to the tree.• The impulse is introduced via the impact screw and absorbed by the supersensitive sensor screw. The result is transmitted to the electronic unit.• OLED display for showing the measurement results• Electronic unit for collecting and saving the measurement data• Integrated Bluetooth function for wireless data transmission to your PC or laptop• Weather and water resistant components for all-weather use• Supersensitive digital micro sensors for high measurement precision• The Micro Hammer localizes:• Decay in the early stages of growth• Brown and white decay• Cavities, wet cores• Cracks in forc areas 10 PORTABLE WOOD DENSITY METER 11 • Density measuring range: 0 gm/cm3 to 3.0g/cm3 • Temperature measurement range: 5℃ to 55℃• Accuracy: Density: ± 0.0005 g/ cm3/ ± 0.01 g/cm3, • Temperature: ± 0.2 ℃ • Repeatability: Density: 0.0002 g/ cm3, Temperature: 0.1 ℃ • Resolution: Density: 0.0001 g/ cm3, Temperature: 0.01 ℃ • Ambient temperature: -10 ℃ to 60 ℃ • Viscosity range: 0.5 to 12cSt at 40 ℃ • Volume of sample: 2 ml • Data storage: 5000 results • Working time: More than 20 hours • Explosion proof grade: Ex la IIC T4 Ga IP level: IP67 • Battery: 3.7 V rechargeable lithium battery Interface: Bluetooth • Dimensions: 245 × 95 × 125 mm Weight: 650 g Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
TenderDetail
Loading tenders