View Bid Results For Wall Paneling Tenders

We found 2767 Bid Results related to wall paneling tenders. You can find Contractor details who won wall paneling tenders along with contract details in Bid awards announcements section.

Filters
Stage
2218
285
264
Tender Publishing Platform
597
2170
State / UT
37
378
292
256
220
195
149
140
118
103
95
93
80
76
76
64
48
44
44
41
40
28
28
20
20
19
18
18
15
13
9
6
5
5
4
4
2
1
Contract Value
636
824
1137
161
Publish Date
12
2
1
0
0
Sector
30
1164
465
368
171
72
70
66
47
36
34
32
31
29
29
23
20
19
13
13
11
11
10
9
6
5
5
3
2
2
1
Ownership
7
1312
1101
181
163
4
4
2
Within keyword
Active filters:
Showing 1–50 of 2767 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
Jammu And Kashmir View Result →
2.
Public Administrative Department #11454032 AOC
Bids Are invited for Furniture Make Stage For Conference Room 6 Ft X 16 Ft X 12 Inch - Water Proof Ply With Laminated Both Side , Conference Room Back Wall Paneling 39 Ft X 9 Ft - Water Proofing And Wall Treatment Using Aluminium Framework , Conference Room Celling Pop 33 Ft X 27.5 Ft Area - Use 2 Sq. Ft. Cement Sheet With White Textured Color , Electrification,Lighting And Wiring For Celling For Conference Room - Installation Of 36 Nos Of 18W Pannel Light In Pop Celling With Electrical Board , Conference Room Ac Dismantling, Shifting, Reinstallation And Wiring , Conference Room Integrated Hidden Storage Wardrobe Make From Wooden Ply And Laminated - Size For Hidden Wardrobe 10Ft X 10Ft , Conference Room Front Table 9Ft X 2.5Ftx 31 Inch - W X D X H 9Ft X 2.5Ftx 31 Inch , Conference Room Window Curtain Roller Type - Roller Type Curtain With Blackout Fabric 5 Ftx 6 Ft , Base Framing For Conference Room Window Curtain Installation - 5.5 Ft , Podium For Conference Room 40 Inchx23 Inchx23 Inch - W X D X H 23 Inchx 23 Inch X 40 Inch , Salon Side Storage Table With 3 Storage And Glass Top - W X D X H 18 Inchx 14 Inch X 36 Inch , Cosmetology Lab Curtain With Celling Mounted Track Length 31 Ft Curved, Curtain Height 9 Ft - Blackout Curtain Fabric With Track System , Cosmetology Lab Electrification,Lighting And Wiring For Celling For Cosmetology Lab - 36 Nos Of 22 W Pannel Light With Electrical Board , Cosmetology Lab Window Glass Covered By Opaque Film - 30 Sq Ft Total Quantity : 32
Contract Date: Ref. Documents Contract Value : 14.19 Lakh
Government Departments No of Bidders 4
3.
Defence #11453177 AOC
Bids Are invited for Ceiling Speakers , Column Array Speakers , Lifier For Ceiling Speakers , Lifier For Column Array Speakers , Digital Signal Processor , Boundary Layer Microphones , On Off Button For Boundary Layer Microphones , Switch Box For Boundary Layer Microphones , Ceiling Tile Microphone Array , Main Display , Side Display , Annotation Panel , Cable Manager For Table , Hdmi Switcher , Hdmi Splitter , Hdmi Extender , Usb Tx Multiformat Switcher , Usb Rx Multi Format Switcher , Usb Data Matrix Switch , Ptz Camera , Speaker Tracking Camera , Hdmi To Usb Capture Card , Voice Tracking Device , Control System With Touch Controller , Network Switch , Room Scheduler , Pdu With Humidity And Temperature Sensor , Ceiling Mount Document Scanner , Equipment Rack , Ups 10 Kva Ups With 60 Min Backup , Ups 3 Kva Ups With 60 Min Back Up , Acoustic Door With Fitting Laminate And Door Frame , Chair , Hot And Cold Ac 2 Ton , Room Air Purifier , Bio Metric Door Access Control , Auto Fire Suppression System For Av Rack , High Quality Wireless Keyboard And Mouse , Led Surface Recessed Mounted Panel With Luminous Web , 12 Channel Signal Dimmer Controller , 12 Channel Controller , Display Keypad Panel For Workstations , Network Router For Automation System , Sitc Supply Installation Testing And Commissioning , Acoustic Wall Paneling , Acoustic False Ceiling , Wooden Conference Table , Executive Chair , Acoustic Carpet Flooring , Power Supply For Lighting Control Network , Lighting Control Communicaiton Gateway Total Quantity : 4070
Contract Date: Ref. Documents Contract Value : 3.84 Crore
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 57.09 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 1.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
10.
Defence #11392755 Technical Bid
Tender for Material And Labour For Plain Cement Concrete 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundation ,Filling And Mass Concrete Complete All As Specified And Directed . , Material And Labour For Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Etc , Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C-1 Using (20Mm Graded Stone Aggregate) As In Bed Blocks For Hold Fast,Coping Errection Of Posts Etc Complete All As Specified And Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) On Slabs Supported On Walls , Beams And Columns In Floors , Roofs,Landings,Balconies, Canopies Deck Slabs, And In Shelves And The Like Complete All As Specified And As Directed. , Material And Labour Reinforced Cement Concrete Nominal Mix (1:1.5:3) Type A1 (Using 20Mm Graded Stone Aggregate) Chajja, Facia Etc And The Like Complete All As Specified And As Directed. , Material And Labour For Plain Cement Concrete 1:3:6 Type C0 (Using 12.5Mm Graded Stone Aggregate) As In Filling The Hollow Portion Of Steel Frame Complete All As Specified And Directed. , Supply Only Water Proofing Compound. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specifed And Directed. , Material And Labour For Brick Work With Sub Class B Bricks, Straight Or Curved On Plan Exc To Any Radius In Half Brick Thick Walls Built In Built In Cm 1:4 Complete All As Specifed And Directed , Material And Labour For Form Work On Flat Sides To Soffits Of Suspended Roof Slabs Not Exc 200 Mm Thick (Horizontal Or Sloping), Walls , Beams And Columns In Floors,Landings,Balconies, Canopies Deck Slabs, And In Shelves Rough Finished Surface Of Concrete All As Specified And As Directed. , Material And Labour For Form Work On Flat Sides To Chajja, Fins, Louvers, Fascia Etc Rough Finished Surface Of Concrete All As Specified And As Directed. , Refixing Wooden Or Aluminium Door Shutters Of Any Description Exceeding 1 Sqm But Not Exceeding 2 Sqm Each In The Same Opening After Taking Down, Easing And Adjusting Including Refixing Builders Hardware, Glass Etc As Required And Renewal Of Unserviceable Screws Concrete All As Specified And As Directed. , Supply And Fix For 2Nd Class Hardwood Plain, Solid, Straight Chowkhats And Frames, Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue, Pinned At Joints Complete All As Specified And Directed. , Supply And Fix Factory Made 30 Mm Thick Flush Shutter Solid Core Construction With Block Board Core & Plywood Face Panels Commercial Type On Both Sides Incl 5Mm Thick Teakwood Leaping Alround Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Factory Made Door, 35 Mm Thick, Glazed And Skeleton Shutters, Open Rebated And Prepated To Receive Glass Gauze Etc (With Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Materials And Revated Sash Bars Any Number , Edges Of Framing Plain Chemfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass In Door Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (A) Complete All As Specified And Directed. , Supply And Fix 2Nd Class Hardwood Glazed And Skeleton Window Shutter 30Mm Thick, Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars, Any Numbers, To Receive Glass, Gauze, Etc Or Provided With Styles And Rails As Specified In Ssr Part 1 Section 8, Clause 8.20 (B) Complete All As Specified And Directed. , Supply And Fix Solid Pvc Door Frame Of Size 50Mm X 47Mm Made Out Of 5Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Factory Made Solid Panel Pvc Door Shutter 30Mm Thick (Style) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Heaving A Pvc Sheet Strip Of 20Mm Width Suck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded/ Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Supplying & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And Directed , Supply And Fix Stainless Steel Wire Cloth 0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm And Fixed With Stainless Steel Stapple Etc Concrete All As Specified And As Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised , Plate Type ,Stove Enameled Black , With Bright Bolt Not Less Than 12Mm Dia With And Incl Minimum Of 6 Bolts And Nuts ,Four On Bolt Plate And Two On Staple Concrete All As Specified And As Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 100Mm Etc Complete All As Specified And Directed. , Supply And Fix Stainless Steel Butt Hinges Cold Rolled Meium Weight Of Size 75Mm Etc Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 150 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Alloy Handles 100 Mm Long Fabricated Type Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 200 Mm Long Complete All As Specified And Directed. , Supply And Fix Aluminium Anodised Barrel Tower Bolts Of Extruded Section 150 Mm Long Complete All As Specified And Directed. , Supply And Fix 300Mm Long Aluminium Alloy Anodised Sliding Door Bolts , With Hasp Staple (Bolt Type) And Fixing Clips Of Sheet Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Section Or Cast-Aluminium Ally Complete All As Specified And Directed. , Supply And Fix Powder Coated Three Track Aluminium Sliding Window With Approved Make Of Following Extruded Section Of Anodised Glazed Shutter As Per Standard Engineering Practices Including All Other Accessories Complete Including 4.00 Mm Thick Tinted Glass Panes, Rubber Beading, Mosquito Proofing, Locking System Etc. Complete All As Specified And As Directed. (Refer Jindal Cat M-2014 ) Aluminium Sections : A Series (I) Shutter Bottom & Top :- 37.50 X 15 X 1.3 Mm Thick (20690) (Ii) Shutter Interlock :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iii) Shutter Side (Handle) :- 37.50 X 23 X 1.3 Mm Thick (20689) (Iv) Frame Bottom :- 75 X 26 X 1 Mm Thick (20671) (V) Frame Top And Sides :- 75 X 26 X 1 Mm Thick (20672) , Supply And Fix Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) Or Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/Neoprene Gasket Required (Fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Material And Labour Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.P. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge , Material And Labour For Structural Steel Work With Rolled Mild Steel Sections As In Main And Cross Beams, Hip And Jack Rafters, Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Conforming To Fe-290 (Gde E-165) Quality A Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 125Mmx60mmx1.25Mm With Double Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.Complete All As Specified And Directed. , Supply And Fix Pressed Steel Frames For Doors Of Size 105Mmx60mmx1.25Mm With Single Rebate Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc.,Complete All As Specified And Directed. , Material And Labour For Mild Steel Conforming To Fe 410-0 Or Fe 310-0 In Framed Work Such As Grills, Gratings, Etc With Ends Of Bars Shouldered And/Or Riveted Or Forged Into Spikes; Framed Guard Bars; Ladders; Railings And Similar Work Complete All As Specified And Directed. , Supply And Fix Box Type Steel Windows With Side Hung Shutters Both Mosquito Proof And Glazed Shutter Including Projecting Type Hinges With Steel Handle And Steel Peg Stay With Glazing Bars And 12 Mm Square Bar Or Ground Bar Of Approved Design Welded To Steel Window Frame Dovetailed Or Welded Complete All As Specified And As Directed. , Supply And Fix Steel Ventilators With Top Hung Shutter Including Hinges, Steel Peg Stay, Complete All As Specified And As Directed. , Material And Labour For Mild Steel Tmt Bars 10 Mm Dia And Over Cut To Length, Bent To Shape As Required Including Cranking, Bending And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia As In Reinforcement Bar Complete All As Specified And As Directed. , Repairing Of Existing Mild Steel Rolling Shutter Of Any Description Or Any Size Including Replacement Of Damaged Mild Steel Laths, Repairing/ Replacement Of Side Guide Channels, Pipe Shaft, Springs, Ball Bearings, Locking Arrangements, Welding Work, Alingment And Smooth Operation, Including Necessary Nuts, Bolts, Oiling And Greasing, Complete All As Specified And As Directed. , Supply And Fix Pre-Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Trapezoidal Profile Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Patteren Corresponding To Is 15965: 2012 Of Durability Class 3, Atmospheric Classification Category 3,Four (4) Coating Class Az 150 Of An Approved Colour Havingb Yield Strength Of 550Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified And As Directed , Material And Labour For Pre- Painted Hot Dip Aluminium Zinc Alloy Metalic Coated Plain Steel Sheet 0.50Mm Thick (Total Coated Thickness), Any Pattern Corresponding To Is 15965 : 2012 Of Durability Class 3, Atmospheric Classification Category 3, Coating Class Az 150 Of An Approved Colour Having Yield Strength Of 550 Mpa As In Roof Covering/Wall Cladding, Fixed With Self Tapping Screws As Specified Complete All As Specified And As Directed. Note: To Be Executed For Provision Of Ridges And Hips. , Material And Labour For 12 Mm Thick Prelaminated Particle Board Bwp Type Melamine Finished (Both Side) For Fixing The Panel Of The Partition/Door Including Necessary Fittings, Gusket, Angle Cleats, Screw Etc Complete All As Specified And Directed. , Supply And Fix Suspended False Ceiling Using E-Grid 2430, 180 Gsm (Exposed Ceiling Suspension System ) Of Grid Size 600Mmx600 Mm With Main Runner 32 Mm X 24 Mm And Wall Angle 24Mm X 24Mm Using 4Mm Thick High Pressure Stean Crude Everest Non Asbestos Fiber Cement Plain Board (E-Board Classic) In & Including A Grid Of Gi System Duly Suspended With 4Mm Dia Gi Wire Hanger Fixed With Steel Dash Fasteners Or Iron Purlin From The Roof With Adjustment Clip Providing Positions For Light Fixtures,Air Conditioning Diffuser And Ducts ,Sprinkler ,Smoke Detectors Etc.The Main Runners To Be Secured To Structural Soffits By Hanger @ 1220 Mm Maximum C/C. The Last Hanger At The End Of Each Main Runner Should Not Be Placed At More Than 450Mm From The Adjucent Wall,Flush Fitting 1220 Mm Cross Tee To Be Interlocked Between Main Runners @ 610Mm C/C,So As To Form 600Mm X 600 Mm Grid Complete All As Specified And Directed. , Material And Labour For Heavy Duty Parking Tiles Size 300Mm X 300 Mm X 10 Mm Thick White Cement And Pigments Of Approved Maked Jointed With Cement Slurry And Pointed With White Cement Mixed With Pigment To Match With The Tiles Over And Including Screed Bed Of 15 Mm Thick In Cement Mortar (1:4) Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8 Mm Thick Area Of Each Tile Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm Thick, In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 7 To 8Mm Thick Area Of Each Tile Exceeding 0.18 And N.Exc 0.38 Sqm In Floor, Shelves Etc, Set And Jointed In Neat Cement Slurry And Pointed In Coloured Cement To Match The Shade Of Tiles Over And Including 15Mm Thick Screed Bed Or Bedding Layer In Cement Mortar 1:4 Complete All As Specified And Directed. , Material And Labour For Non Skid, Ceramic Coloured Tiles 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exc 0.18 And N.Exc 0.38 Sqm , In Skirting Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Including 10Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. , Material And Labour For Coloured/ Printed Glazed Ceramic Tiles 7Mm Thick Not Exc 0.15 Sqm In Area In Vertical Surfaces I.E. Dado, Skirting, Etc., Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, Laid Over And Including Screed Or Screed Bed 10Mm Thick In Cement Mortar 1:4, Complete All As Specified And As Directed. , Material And Labour For 75Mm Thick Cement Concrete 1:3:6 Type C-2 (Using 40Mm Graded Stone Aggregate ) As In Plinth Protection Complete All As Specified And Directed. , Material And Labour For 100Mm Thick Cement Concrete 1:2:4 Type B-2 (Using 40Mm Graded Stone Aggregate) As In Flooring, Hardstanding Complete All As Specified And Directed. , Material And Labour For 100 Mm Thick Plain Cement Concrete 1:4:8 Type D2 (Using 40Mm Graded Stone Aggregate) In Foundation, Floor Etc Complete All As Specified And Directed. , Material And Labour For 25 Mm Thick Plain Cement Concrete (1:2:4) Type B0 (Using 12.5 Mm Graded Crushed Stone Aggregate) As In Floor Finished Rough To Receive Tiles Complete All As Specified And As Directed. , Material And Labour For 10Mm Thick Rendering On Other Than Fair Faces Of Brick Wall In Cm 1:6 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement With Using Wpc @3% By The Wt Of Cement. Wpc Shall Be Measured And Paid Seperately. , Material And Labour For 5Mm Thick Rendering On Fair Faces Of Brick Or Concrete Surface In Cm 1:3 Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. , Material And Labour For Rendering 15Mm Thick External In Cm 1:4 On Fair Faces Of Brick/Concrete Surfaces Finished Even And Smooth Without Using Exta Cement Complete All As Specified And Directed. , Material And Labour For Preparation Of Newly Plastered Surface Of Wall And Applying A Coat Of Alkali Primer And Two Coats Of Acrylic Distemper Complete All As Specified And Directed , Material And Labour For Preparation Of Newly Plastered Surface Of Walls And Applying Two Coat Of Acrylic Exterior Weather Coat Paint (Weather Proof Paint With Quality Of Dust Guard, Anti Algal And Anti Fungal Paint With Minimum 05 Years Performance Warranty, Over A Coat Of Approved Primer Over 1Mm Thick Water Proof Putty Of Same Manufacturer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Wall Surface And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Material And Labour For Preparing Of Newly Plastered Ceiling Surface And Applying Three Coats Of White Wash Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For 4Mm Thick Sheet Glass Figured Glass, Pin Head Type And Glazing With Oil Putty In Square N-Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed. , Material And Labour For Preparation And Applying Two Coats Of Synthetic Enamel Paint On New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Over A Coat Of Pink Primer Complete All As Specified And Directed. , Material And Labour For Preparation Of Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide On New Steel Surfaces , Over 10 Cm In Width Or Grith Not Other Wise Described Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 15Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix Steel Water Tubes, Medium Grade, Isi Marked, Galvanised, 20 Mm Bore With All Fittings, Fixed To Walls And Ceiling Or Laid In Floors Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Hand Basin White, Flat Back Of Size 550Mmx400mm Fixed On And Including Cast Iron Cantilever Bracket, 32Mm Dia Pvc Waste Coupling And 32 Mm Dia Pvc Waste Pipe Including Fixing Of Tap, Waste Fitting Etc Complete All As Specified And Directed. , Supply And Fix In Repair Bib Taps With Wall Flange 15Mm Bore, Fancy Type, Quarter/Half Turn, Brass Chromium Plated, Long Body With Capstan Head And Cup Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Including Accessories Complete All As Specified And Directed. , Supply And Fix In Repair 125 Mm Dia, Chromium Plated Swivel Type Shower Rose With 195 Mm Long Chromium Plated Shower Arm And Wall Flange Suitable For Fixing 15Mm Bore Iron Pipe All As Specified And Directed , Supply And Fix In Repair Bath Wall Mixer With 15Mm Bore (Dia) Spout, Chromium Plated With Long Bend Pipe For Over Head Shower Including Flanges Complete All As Specified And As Directed. , Supply And Fix In Repair Pillar Taps, Cast Copper Alloy, With Capstan Heads, Fancy Type, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered ‘Hot Or ‘Cold With Long Screwed Shanks And Fly Nuts, Screwed For Iron Pipe 15 Mm Bore Complete All As Specified And Directed. , Supply And Fix In Repair Cp Stop Valve/Angle Valve 15 Mm Bore, Fancy Type Cromimum Plated With Long Shank And Cup (Concealed Type), High Pressure Crutch Or Butter Fly Handle Screwed Both Ends Screwed For Iron Pipe Or For Unions Complete All As Specified And Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 1000 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places With Fittings And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix In Repair Rotational Moulded,Multilayer Hdpe Water Storage Tank Of 500 Ltrs Capacity(Cylindrical Vertical With Closed Top) Isi Marked Fixed In Position On Existing Places Complete And Refixing Of Inlet, Outlet & Overflow Pipe Etc, Complete All As Specified And As Directed. , Supply And Fix Ball Valves 20Mm Bore Dia Of Pipe High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed (Minimum Weight 20Mm-210Gms). , Supply And Fix In Repair 600Mmx450mm Bevelled Edge Mirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers , Supply And Fix In Repair Pvc Valve, Symphonic Action Type, Flushing Cistern 10 Liters Capacity Low Level White With Inlet ,Ball Valve ,Float And Handle Including Brocket Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Pvc (Swr) Pipes, Presure Rate Having 6 Kgf Single Socketed In Any Length With Rubber Ring Joints And Laid In Trenches As In Waste/Soil Pipe Complete All As Specified And As Directed. , Supply And Fix 110Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Complete All As Specified And As Directed. , Supply And Fix 75Mm Dia Bore Pvc (Swr) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Fixed To Walls Or Floor Complete All As Specified And As Directed. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 75 Mm Bore Complete. , Supply And Fix Pvc (Swr) Bends With Access Door Any Radius, 110 Mm Bore Complete. , Supply And Fix, In Repair Vitreous China Wash Down Water Closet Of Orissa Pattern Size 580 X 440 Mm White With Integral Foot Rests Including Removing Filled Lean Concrete From Sunken Portion And Putting Of Lean Concrete After Treatment Of Sunken Slab, Connection To Trap And To Flushing Pipe Etc Complete And Making Good To Floor Complete All As Specified And Directed. , Supply And Fix In Repair Vitreous China Wash Down Water Closed Pan (Pedestal Pattern) With P Or S Trap White, Including Connection To Trap And Cistern, Flush Pipe Including White Plastic Water Closet Seat Cover, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Making Good Disturbed Surface Of Floor Complete All As Specified And Directed. , Supply And Fix In Repair Plastic Water Closet Seat Cover, White, Closed Pattern With Flat Bottom & Cover And Aluminium Anodised Hinging Device And Fixed Wc Pan Complete All As Specified And Directed. , Dismantling Plain Or Corrugated Steel Sheeting Any Gauge Thickness Including Nanital Or Similar Pattern Roof Covering , Taking Up Or Down 20 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Up Or Down 15 Mm Bore Steel Water Tubing And Connections Including Cleaning For Refixing Or Removal To Store Complete All As Specified And Directed. , Taking Down Door Chowkhat With Shutter Area N-Exc 1.5 Sqm Each(Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Chowkhats Or Frames With Shutters Exc 1.5 Sqm But Not Exc 4 Sqm Each (Without Taking Off Shutters From The Frame) Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Of Any Description N. Exc 1 Sqm Each Complete All As Specified And Directed. , Taking Down Shutters Of Wooden Or Aluminium Door Any Description Area Exc 1 Sqm And N Exc 2 Sqm Each Complete All As Specified And Directed. , Dismantling Wall And Ceiling Boards Or Insulation Boards, Any Thickness, Any Description, Including Cover Fillets Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete (Reinforcement Cut As Required To Facilitate Demolition) Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And As Directed. , Taking Down Cement Plaster Of Any Description On Brick Or Stone Walls Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. , Demolition Of Brick Work Built In Cement Mortar Or Cement Lime Mortar , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Trusses Etc Complete All As Specified. , Demolition Of Stone Slabs And Tiles Laid Dry And Dry Or Pointed Of Any Description Or Thickness Infloors, Aprons Etc. , Dismantling, Floor Hearth Or Wall Tiling Inclduing Cement Mortar Bedding And Removing Rubbish Off The Premises Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Not Exc. 15 Cm Thickness (Below Or Above Ground Level) Complete All As Specified And Directed. , Demolition And Breaking Up Drain Waste Pipes (Sgsw, Ac Or Rcc, Ci ) Of Internal Dia 75/110 Mm, Set In Cement Mortar In Any Position Complete All As Specified And Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 1.16 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu and Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 12.57 Lakh
Local Bodies No of Bidders 1
14.
Defence #11359685 AOC
Bids Are invited for Customised Table Top For Coffee Or Tea Kettle Microwave Induction Cook Top Size 5 Ft 3Ft With Multi Drawers For Storage Of Utensils , Fabrication Of Customised Wall Mounted Storage Space 6Ft X 1.5Ft With 2 Stacks For Crockery And Other Utensils With 2 Stacks For Crockery , Customised Wall Mounted Display Case Of 6Ft X 1.5Ft Of Three Stacks With Glass Enclosures With Locking Arrangement , Customised 2Mm Thick Blackout Double Layered Zebra Blinds With Open Or Shut Mechanism , Wall Paneling Wit Charcoal Or Pvc Profiles , Anti Termite Hadr Material Wall Paneling , Light Emitting Diode 75 Inches Diagonally Visual Display , Customised Wooden Book Or Magazine Shelve , Laying Of Fine Finish Putty And Finishing With Royal Emulsion Coat , Laying Of Electrical Cales, Metal Boxes, Control Units And Sockets For Profile Illuminations, Hanging Illumination, Spot Illuminations And Diffusers And Other Necessary Power Related Materials , Customised Tough End Glass Enclosures With Shut And Close Hydraulic Mechanism And Other Accessories With Wood Wall Paneling Around The Enclosure , Customised Cushioned Seating Arrangemens With Fine Fabric Finish Seater , Customised Solid Teak Wood Table With Fine Polish Finish , Customised Step Design And Profile Weather Proof Ceiling Fabricaed With High Density Galvanized Channels And 12Mm Thick Gypsum Sheet , Fabrication Of Customised Wall Mounted Covering Arrangement For Network Switches With Door And Top Mounted Exhaust Fans Total Quantity : 2415
Contract Date: Ref. Documents Contract Value : 20.94 Lakh
Government Departments No of Bidders 7
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
Jammu And Kashmir View Result →
Contract Date: Jun 25, 2026 Contract Value : 5.23 Lakh
Boards / Undertakings / PSU No of Bidders 3
Chhattisgarh View Result →
17.
Public Administrative Department #11341545 Price Bid
Tender For Annual Plan-Malayattoor Neeleeswaram Gp Pro No 296/26 Anganwady Maintenance Ward 14-26-General Civil Work-25/26.; 1 Maintenance of building 2 50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood 3 50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood 4 OD272292/2025-2026:od1753817/2022_2023: Engaging carpenter for repairing doors and windows 5 OD277312/2025-2026:coolie 6 OD274359/2025-2026::Providing and fixing factory made PVC door including cost of all fittings, labour charges etc complete (Approved Data of CE LSGD vide circular dated 18.08.2016) OD-11, DSR 2016 1.4902 dtd 05.06.201 7 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 8 OD277227/2025-2026:Laterate masonry with neatly dressed DEPARTMENTALlaterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 9 50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete 10 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). 11 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 12 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
18.
Public Administrative Department #11334085 Price Bid
Tender for Annual Plan-Tholicode Gp-64/2025-26: -Panacode Maintenance Of Gramakendram-General Civil Work-1 MAINTENANCE OF PANAKKODU GRAMAKENDRAM1.001 15.28.1:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet1.002 15.17.1:Dismantling steel work in single sections including dismembering and stacking within 50 metes lead in:R.S. Joists1.003 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar1.004 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below1.005 15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.1.006 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete1.007 OD377884/2025-2026: Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.1.008 OD377883/2025-2026:Supplying and fixing 150mm dia PVC rain water gutter SQUARE section including fitting with 32mx5m MS flat supporters at 1m interval etc. complete1.009 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)1.01 13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster1.011 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete1.012 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)1.013 21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) 1.014 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides1.015 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil1.016 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
19.
Public Administrative Department #11325415 AOC
Tender For Maintenance Of Municipality Abcd Blocks-General Civil Work; 1 MUNICIPAL OFFICE A&B BLOCK 2 OD429488/2023-2024:Labour engaged for cleaning surrounding area 3 OD429932/2023-2024:Cleaning the tiled surface and removing dirt, dust , bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agentEngineer - incharge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building / structure, all as per direction of Engineer- in- Charge ( The rate is inclusive of all materials & labours involved except scaffolding). 4 14.76:Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. 5 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 6 50.18.9.11.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 15 mm dia 10 Kgf/cm2- External work - Exposed on wall 7 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 8 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. 9 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 10 21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 11 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 12 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 13 OD334510/2025-2026:200mm wide uPVC square rain water gutter,UPVC qutter clamp,UPVC end cap,joints etc 14 OD334511/2025-2026:Providing and fixing steel bib cock of approved quantity conforming to IS: 8931 15 OD334512/2025-2026:Supplying and fixing 75mm dia PVC pipe for the down water (4kg/cm2) 16 OD334513/2025-2026: Providing and fixing factory made PVC door including cost of all fittings, labour charges etc complete (Approved Data of CE LSGD vide circular dated 18.08.2016) OD-11,DSR 2016 1.4902 dtd 05.06.2017 17 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 18 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 19 50.9.11.2:Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. Please Enable Macros to View BoQ information
Contract Date: Jun 22, 2026 Contract Value : 4.23 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
22.
Heavy Industries and Public Enterprises #11321092 Technical Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Barpeta, Assam- 1 Civil Works 2 Solid Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 3 12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 4 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 5 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 6 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 7 Providing And Laying Premiumvitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier,Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Size Of Tile 600 X 1200 Mm 8 Providing And Laying Premium Vitrified Wall Tile In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600 X 1200 Mm 9 Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 10 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 11 Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is : 14856, Complete As Per Direction Of Engineer- In-Charge. 12 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 13 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 14 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 15 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm,With Swan Neck Faucet With Pipe In Let And Drain Provision, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510X1040 Mm Bowl Depth 250 Mm 16 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms 17 Providing And Fixing Cp Towel Rod Complete Fixed With Cp Brass Screws Of Approved Quality Of Minimum 600Mm Length Approved As Per The Requirement Of Engineer In Charge. 18 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: 45 Cm Length15 Mm Nominal Bore 19 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 40 Mm Dia 20 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 21 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 10Kgf/Cm2 22 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work,Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf/Cm2 23 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall 24 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall 25 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 26 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75X75X75 Mm Dia Door Tee 27 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Bend 28 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 29 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes,Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 30 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 31 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 32 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X110 Mm Dia Door Tee 33 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 34 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall 35 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Partition Of Approved Brand And Manufacture, Including Top & Bottom Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Fittings, All Complete As Per Direction Of Engineer-In-Charge. 36 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately) 37 Providing And Fixing Ss H Handle Having Min 45 Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete. 38 Providing And Fixing 3M Fasara Frosted Etching Film Of Thickness 25 Microns Self- Adhesive Of Approved Colour, Shade, And Quality With Cutting As Per Approved Design And Pattern, Including Cleaning Of Glass And Making Surface Smooth For Fixing Of Film To The Surface, All Completed As Per The Direction Of The Engineer In Charge. 39 Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete 40 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 41 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 42 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides 43 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 44 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/ Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete,Complying To Astm C920, Din 18540-F & Iso 11600Upto 5 Mm Depth And 5 Mm Width 45 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 46 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 47 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In- Charge. 48 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 49 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 50 Vinyl Transparent Vision Glass Stickers: Supply And Pasting Of Vinyl Transparent Vision Glass Stickers In Approved Size And Design In Glass Partition And Door As Per The Instruction Of Engineer In Charge. 51 Backlit Acrilic Board With Projected Letters: Supply, Installation, Testing And Over Suitable Welded And Painted 25X25X3Mm Ms Angle Frame In Suitable Location And In Proper Line And Level With All Necessary Fastners, Supports Etc. Electrical Works Likes Electrical Wirings, Connections, Fittings, Externaly Fixed Weather Proof 2/3 Pin Plug Points And Sockets Including Boxes Etc. To Be Complete Properly. All Fabrication And Fixing Should Be Done As Per Approved Design And Instructions Of Engineer In Charge. (Note: Only Front Elevation Will Be Measured.) 52 Furniture 53 Supply And Erection Of Airport Type 3 Seater Waiting Chair With Powder Coated Chromium Finish Having Minimum Dimensions 1675Mm Length X 710Mm Width X 775Mm Total Height And 400Mm Seat Height . Seat: High Quality Cold Rolled 1.2Mm Thick Steel Perforated Sheet Pressed And Welded To Form The Shape. Arm & Leg: High Quality 1.2Mm Thick Ms Tube / Sheet . Cross Bar: High Quality Cold Rolled 2Mm Thick Steel Sheet Pressed And Welded To Form The Shape. 54 Supply Of Phlebotomy Chair With Optimum Design Made Up Of Ms Power Coated Frame And Up Upholstery Type Seat,Back Rest And Arm Rests.Both Side Arm Rest Should Be With Height And Position Adjustable System And All As Per The Instruction Of Engineer In Charge. 55 L-Type Workstation Of Overall Size (1350 * 600)Mm + (1000 * 450)Mm X 750 Mm (L X D X H) And Pedestal Unit Made Up Of 18 Mm Thick Exterior Grade-I Mdf Board On All Sides Conforming To Is:14587 From Approved Makes Such As Century/Greenply/Fineply Or Equivalent With Decorative Laminate On Both Side And All Edges To Be Fixed With 2Mm Thick Pvc Edge Beading. One Three-Drawer Modular Pedestal Unit Of Minimum Size 450 Mm (W) X 500 Mm (D) X 650 Mm (H) All With Retractable Key Board Tray, Drawer Channels, Hinges, Handles, Individual Locking System, And All Necessary Fittings And The Workstation Should Have An Electrical Flip Box With 2 Nos Universal Power Socket & 1 No Data Socket Etc And Cable Management Tray. All Work As Per The Approved Design And Instruction Of The Engineer-In-Charge/Architect. 56 Providing And Erection Of Reception Counter Table Of Length 1200 Mm And First Level Should Be Provided At A Height Of 750 Mm And Width 600 Mm And The Second Level At A Height Of 1050Mm From Base With A Width Of 300. The Table Made Of 18Mm Thick Pre Laminated Medium Density Board Of Exterior Grade (Grade I) Is: 14587:1998 With Decorative Laminated Finish On Both Sides And 2 Mm Thick Pvc Beading On All Edges, Including Electrical Flip Box, Cable Measurement Tray, Grommets With 3 Nos Universal Power Socket And Ethernet Port, Three Drawer Pedestal Unit With Drawer Channel, Handles, Hinges, Lock All Complete As Per Approved Drawing And Installation Of Engineer In Charge/Architect. 57 Supply And Installation Of Visitors Chair Medium Back, Mesh Back Cushion Seat With Fixed Supports Made Of 304 Stainless Steel/ Powder Coated Ms Of Approved Colour Or Shade As Per The Instruction Of The Engineer In Charge 58 Revolving Chair: Medium Back Ergonomic Chair With Five Nos. Star Shaped Nylon Base. Castor: 50Mm Diameter Nylon Twin Wheel, Gas Lift Height Adjustment, Back Angle Adjustment , Fixed Armrest Providing Natural Resting For Arms. Seat With Pu Coated Foam Backed Fabric, Back Rest With Mesh Type Fabric, Upholstery: Heavy Duty Rubber Backed Fabric In Black 59 Counter Height Stools :Supply And Erection Of Counter Height Stools ( Bar Stools ) Of Following Specifications : Revolving Adjustable Chrome Plated Steel Body Chairs With Resistance To The Corrosion. Cushion Seat With Lift Mechanism For Adjustment Of Height. Minimum Height 750Mm Before Expansion. Medium Back Rest And Arm Rest. Item Shall Be Of Reputed Make. 60 Supplying And Fixing Of Lab Work Table With 18 Mm Thick Edge Moulded Granite Top Supported Over 18Mm Thick Marine Ply Wood Of 2500Mm,L X 1200Mm,W X 850Mm, H And Powder Coated Gi Frame Of Section Size Not Less Than 50X50X1.5 Mm Including And Providing 4 Nos Under Storage Movable Cabinents Of Size 600Mm,L X 450Mm,D X 750 Mm,H And Powder Coated Steel Sheet Of Thickness Not Less Than 1Mm With 1 Drawer And Partition Bottom Storage Space With Door Including Drawer Channels, Individual Locks And Handles All As Per The Approved Drawing And Instructions Of Engineer In Charge 61 Lab Work Bench -The Work Bench Top Made Up Of 18Mm Thick Granite Top Edge Moulded Over 18 Mm Thick Marine Plywood And Gi Powder Coated Frame Work Of Section Size Not Less Than 50X50X1.5Mm. The Width Of The Table Shall Be 750Mm And Height Shall Be 850Mm. The Frame Provided With Level Adjusting Screws Fixing Accessories ,Carriage Of Material All Complete As Per The Approved Drawings And Direction Of Engineer In Charge.Note Only Length Of The Table Shall Be Measured For Making Payment. 62 Cabinet/Wardrobe: Providing And Errection Of Cabinet/Wardrobe Unit Made With 18 Mm Thick Prelaminated Mdf Board Of One Side Decorative Lamination And Other Side Balancing Lamination Having Total Unit Dimension Of 900Mm,L X 450Mm,Dx 2400Mm,H And All Edges To Be Sealed With Pvc Edge Beeding Of 2.00 Mm Thick Including All Fittings Such As Autoclose Hinges,Chromium Plated Brass Individual Locks & Handles ,Tower Bolts Etc All Required. All Shelves To Be Fix With Proper Support And Bracket Holders At A Spacing Of 400 Mm Centre To Centre And All As Per The Drawings And Instruction Of Engineer In Charge. Board Make : Greenlam/ Merino / Century/ Equivalent . Only Front Elevation Will Be Measured. 63 Overhead Storage: - Providing And Fixing Overhead Storage Unit With Minimum 18 Mm Thick Pre-Laminated Medium Density Fiber Board Exterior Grade (Grade-I) Is: 14587:1998 Marked With One Side Decorative And Other Side Balancing Lamination. Cupboard Shutters Edge To Be Sealed With Pvc Edge Bending Tape 2.00 Mm Thick Of Approved Brand Including Isi Marked Nickel Plated Bright Finishing M.S. Piano Hinges Conforming To Is:3818 Marked With Fixing Chromium Plated Brass 50 Mm Cupboard Or Wardrobe Knobs, Special Quality Chromium Plated Brass Cupboard Locks With Six Levers Of Approved Quality Including Necessary Screws Etc. Complete. Only Front Elevation Will Be Measured. 64 Electrical- Wiring 65 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 66 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 67 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 68 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 69 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire 70 Fixtures 71 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socketoutlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Beused In Non Residential Buildings) 72 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Ampsmodular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required 73 Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front Onsurface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25A Modular Sp Mcb, C Curve Including Connections, Painting Etc. Asrequired. 74 Supply, Installation Of Surface Mounted Led Tubelight. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification. Luminaire Shall Be Designed To Emit At Least 3600Nominal Lumens And Efficacy Of Atleast 105 Lumen/Watt And Minimum System Wattageof 30 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Upto 30% Over 25K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. Make - Philips, Crompton, Wipro, Havells 75 Supply And Installation Of Surface/Recess Mounted Led Round/Square Luminaire With Crca Housing Suitable With Fully Diffused Diffuser For General Lighting In Offic Eareas. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K, Cool White Light. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification.Luminaire Shall Be Designed To Emit At Least 1000 Nominal Lumens And Efficacy Ofatleast 105 Lumen/Watt And Minimum System Wattage Of 10 -15 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Up To 30% Over 50K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. For Light Fittings To Be Installed In False Ceiling, All Required Cuttings Shall Be Made And Damages Shall Be Made Good As Per The Direction Of Engineer In Charge. Make-Philips, Crompton, Wipro 76 Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep - 5 Star Rated, 3 Blade Ceiling Fan Complete With 300Mm Down Rod, Canopies,Shackles. 77 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existingmodular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 78 Supplying, Conveyance And Installation Of 3 Blade, 400 Mm Sweep, 1400 Rpm Wall Mount Fan Including Frames And All Mounting Accessories Complete. Recommended Make: Usha/ Havells/ Bajaj / Almonard Or Equivalent 79 Supplying, Conveyance And Installation Of 150 Mm Sweep,1800 Rpm Exhaust Fanincluding Frames And Allmounting Accessories Complete. Recommended Make: Usha/Havells/Bajaj Or Equivalent 80 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. 81 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. 82 Supply, Installation Of 12 Watt Led Bulb. 83 Db And Switchgear 84 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) 85 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door 86 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 87 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 88 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 89 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existingmcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63Amps 90 Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30Milli Amperes In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required.63 Amps 91 Supplying And Fixing Cable End Boxes (Ip 43) Suitable For Following Single Poleand Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess,Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Spn Mcbdb 92 Cctv And Networking 93 Supply, Conveyance And Installing Of 2Mp Ip Dome/Bullet Camera Having 1/3Progressive Scan True Day And Night Colour Ir Camera Having Effective Pixel Of 2Mp, Video Frame Rate Of 2Mp @30Fps, Minimum Illumination Of 0.01 [email protected], 0Lux@Ir On, 20 M Ir Range, 24 Ir Led, Awb, Agc, Blc, 2D Noise Reduction,With 3.6Mm Board Lense, 12 Vdc, Poe Ip67 Rated Weatherproof Performance. 1 Year Warranty. Make: Bosch/Cp Plus/Honeywell Or Equivalent 94 Supply, Installation And Integration Of 8 Channel Embedded Linux Poe, Nvr (Network Video Recorder), Having Dual Core Embedded Processor, Must Connect 8 Channel Ip Cameras , Should Support Min 2 Sata Hdd Each Of 6Tb And Must Recordvideo Simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smartevent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(Hevc)/H.264+/H.264, 2 Year Warranty, Image Quality Should Be Maintainedthroughout The Warranty Period. Make: Bosch/Cp Plus/Honeywell Or Equivalent 95 Supply And Installation Of Network Switch. 8 Port Poe Switch 1000Base-T Copper Ethernet Poe+ Connections, 10M/100M/1G Rj-45 Copper Ports, 1000Base-X Fiber Sfp Ports, 8 Port Auto Sensing 10/100/1000 Mbps Poe, Minimum Cpu Memory 512 Mb With 2 Sfp/Combo Ports, Energy Efficient Ethernet (Ieee 802.3Az). Make: Cisco/Cp Plus/ Netgear Or Equivalent 96 Supply And Fixing Of 6U Wall Mounting Rack With Supply And Fixing Of Mounting Brackets For Support Lockable Front Door And Detachable Side Doors, Cable Manager And Pdu Of 4 Or 6 Sockets Including Cooling Fan With Accessories Complete 97 Supply And Installation Of 8Tb Hard Disk 98 Supply And Installation Of Led Color Monitor Of Minimum 32 Inch Screen, Complete,Uhd Display Make: Lg/Samsung/Panasonic Or Equivalent. 99 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable 100 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 101 Supplying And Fixing Rj45 Outlet Including Cover Plate, Keystone Jack And Gang Box Supporting, Connection Etc. As Required 102 Air Conditioning System 103 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Followingcapacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Single Phase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 2 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 104 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Following Capacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Singlephase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4 M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 1.5 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 105 Supply And Installation Of Additional Copper Piping, Cabling From Indoor To Outdoor And Drain Piping For Air Conditioning Unit With Proper Insulation Including All Required On Wall/Above False Ceiling Complete 106 Supply, Installation, Testing And Commissioning Of True On-Line Double Conversion 6 Kva Ups System With 1:1 Crest Factor Single Phase Phase Input – Singlephase Output. Inversion Shall Be Microprocessor Controlled With Instantaneous Sine Wave Control Using Igbt. Ups Shall Have Standard Display Features, Alarms, Safeties, Etc Input Voltage Range : A) Phase & Single Phase With Ground B)Votage Range 190 Vac & 250 Vac C)Input Frequency : 50/60 Hz D)Power Factor : 0.95 Or Above E)Thd : Less Than 5% With Full Load Bypass F) Voltage Range & 200Vac & 240 Vac G) Frequency Range – 45-55 Hz/55-65 Hz Output Voltage Range H)Voltage Range & 200Vac & 240 Vac I)Frequency Range & 50/60 Hz J)Voltage Distortion & Linear Load = 2% K)Voltage Distortion – Nonlinear Load = 5% L)Output Waveform – Pure Sinewave M) Minimum Back Up Time : Continuous 60 Minutes At Full Load Rectifier Shall Be Full Wave Type (Shall Fully Meet The Specified Input Power Requirements) Battery Type: Sealed Lead Acid Maintenance Free Dc Voltage : 24/48/96V Dc System, Battery Nos And Capacity Shall Be Designed For Optimum Storage Space. Make: Liebert Vertiv/Apc By Schneider/Numeric By Legrand 107 Visi Cooler And Refrigerator 108 Supply And Installation Of 260 Litre Refrigerator, Direct-Cool Model With A Minimum 3-Star Bee Rating And Stabilizer-Free Operation. It Shall Use Eco-Friendly Refrigerant (R600A) And Have A High-Efficiency, Low-Noise Compressor. The Unit Shall Include Toughened Glass Shelves, A Vegetable Crisper, Bottle Storage For 2L Bottles, An Internal Freezer Compartment, And A Removable Anti-Bacterial Gasket. It Shall Operate On 230V, 50Hz Ac And Include Standard Accessories Such As An Ice Tray And Egg Tray. The Refrigerator Shall Have 1-Year Comprehensive Warranty And 10-Year Compressor Warranty, With Bis Certification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
26.
Coal and Mines #11310897 Technical Bid
Tender For Repairing Of Nhs Q.No-192/383, 192/384, 194/387, 195/,390, 196/391, 196/392, 197/393, 197/394, 198/395, 199/397, 199/398, 200/399, 200/400, 201/401, 201/402, 202/403, 203/405, 205/410, 207/,413, 207/414, 209/417, 209/418, 210/419, 210/420, 211/421, 219/438, 220/439, 220/440, 222/444, 229/457, 229/458, 230/460 And 236/472 At Urjanagar Colony Under Rajmahal Area.-1 Item Description/ Heading 2 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natual Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natual Sources) 3 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. Second Class Teak Wood:30 Mm Thick Shutters 4 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Fixed Portion. Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) 5 Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 6 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Fine Sand) 7 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer 8 Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture To Give An Even Shade: Old Work (One Or More Coats) 9 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 10 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqmover And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 11 Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq. Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead : With Cement Mortar 1:4 (1 Cement : 4 Fine Sand) 12 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 13 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : One Or More Coats On Old Work 14 Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty: Float Glass Panes Of Thickness 4 Mm 15 Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : Long Pattern W.C. Pan Of Size 580X440 Mm 16 Taking Out Existing Wooden Door Shutter, Repair By Cutting, Painting Etc. And Refixing Of Repaired Door Shutters To Existing Door Frames, Including Replacement Of Hinges With Screws, Etc. As Required All Complete As Per The Direction Of The Engineer-In-Charge. 17 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 18 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require :White Vitreous China Angle Back Wash Basin Size 400X400 Mm With Single 15 Mm C.P. Brass Pillar Tap 19 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required :Kitchen Sink Without Drain Board 470X420 Mm Bowl Depth 178 Mm 20 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe. 32 Mm Dia 21 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall:15 Mm Dia Nominal Bore 22 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc. Internal Work - Exposed On Wall:25 Mm Dia Nominal Bore 23 Providing And Fixing Brass Bib Cock Of Approved Quality : 15 Mm Nominal Bore 24 Providing And Fixing Brass Stop Cock Of Approved Quality : 15 Mm Nominal Bore 25 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 15 Mm Nominal Bore 26 Providing And Fixing Mirror Of Superior Glass (Of Approved Quality) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing :Oval Shape 450X350 Mm (Outer Dimensions) 27 Grading Roof For Water Proofing Treatment With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) 28 Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 29 Marble Work Gang Saw Cut (Polished And Machine Cut) Of Thickness 18 Mm For Wall Lining (Veneer Work), Backing Filled With A Grout Of Average 12 Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Pointing With White Cement Mortar 1:2 (1 White Cement : 2 Marble Dust) With An Admixture Of Pigment To Match The Marble Shade (To Be Secured To The Backing By Means Of Cramps, Which Shall Be Paid For Separately). Raj Nagar Plain White Marble/ Udaipur Green Marble/ Zebra Black Marble. Area Of Slab Upto 0.50 Sqm 30 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry 3.3Kg Per Sqm, Including Pointing In White Cement And Matching Pigment Etc. Complete. 32 Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand). 33 Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:4 (1 Cement :4 Coarse Sand) 34 Total Impact Of Gst For The Purpose Of Ctc Total In Figures Quoted Rate In Figures Quoted Rate In Words
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
27.
Communications and Information Technology  #11310654 Technical Bid
Tender for Provision Of Pvc Wall Paneling In Inspection Quarter At Ptc Saharanpur
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 17,810
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
29.
Public Administrative Department #11300743 AOC
Tender For Lac-Ads-Lac Ads 2025-26 Sri. T P Ramakrishnan Mla - Tm Balakurupp Grandhalayam Manava(Avala) Cheruvannur Pt-Perambra Constituency-General Civil Work- 1 Building cocstruction 2 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 4 51.2.3:Filling with Quarry Muck
Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade 5 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 6 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 7 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 8 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 9 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 10 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 11 50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. 12 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 13 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 14 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 15 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 16 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 17 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 18 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 19 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 20 50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 21 OD410732/2025-2026:Supplying fabricating PVC door with frame in locally available best quality including cost of all fittings, labour charges etc.complete. 22 50.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete 23 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 24 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 25 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 26 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) 27 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 28 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 29 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 30 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 31 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 32 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 34 17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 35 50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 36 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 37 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 38 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 39 51.19.ST2:Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)
2. 15 to below 25 flush capacity 40 50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall 41 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall 42 50.18.9.7.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 43 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 44 50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 45 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 46 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 47 50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow 48 50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 49 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow 50 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow 51 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 52 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 53 50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 54 18.15.1:Providing and fixing brass bib cock of approved quality :15 mm nominal bore 55 18.58.1.1:Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia Please Enable Macros to View BoQ information
Contract Date: Jun 17, 2026 Contract Value : 24.12 Lakh
Government Departments No of Bidders 2
30.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 49,500
Statutory Bodies & Commissions/Committees No of Bidders 3
32.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
35.
Public Administrative Department #11267722 AOC
Tender For Annual Plan-Pro.No.503/24-25 Kodenchery Gp-Cdmc Building Construction-General Civil Work - BUILDING CONSTRUCTION 2 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 3 OD470511/2024-2025:DRY RUBBLE MASONRY-Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc complete as per direction of departmental officers at site. 4 OD475039/2024-2025:Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction,of approved size design shape laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand ,filling the joints with fine sand etc.all complete as per the direction of Engineer-in-charge. 5 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 6 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 7 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 8 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 9 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 10 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 11 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 12 10.5.2:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 13 13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) 14 OD477791/2024-2025:supplying and fixing pvc door frame 53x65 mm or nearest available size with vertical frae joints fitted for pvc head providing concealed reinforced motor cut and welded corners on computer aided machine,tie rod at the bottom to keep the frame iron hollow connecting elasto metric gas cutting grooves etc complete 15 OD477724/2024-2025:supplying and fixing pvc door shutter to suit the door frame already fixed using 200 mm wide collar pvc planks in shutter frame 24 mm thick and 60 mm wide with retaining by long by long classified materials in inter ale joints completely selected cover and lifted directly to the connected steel reinforcement for door frame including all cost conveyance and labour charges etc complete 16 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 17 21.2.1:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side 18 21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 19 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 20 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 21 50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete 22 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Contract Date: Jun 10, 2026 Contract Value : 8.40 Lakh
Government Departments No of Bidders 2
36.
Defence #11261520 AOC
Bids Are Invited For Bevarage Counter With Quartz Stone On Top, Size 10X2.5 Ft Italian Marble On Front Side And Indirect Lighting With Provision Of Hanging Wine Glasses On Top , Glass Frame Background Of Size 12X8X1 Ft With Full Glass And Profile Lighting On Each Vertical Lap With Provision Of Locking Arrangement , Modular Cupboard Of Size 8X5 On Both Side Of The Bar Counter With Provision Of Profile Lighting , Bar Chairs In Round Shape And With High Back Support Customized Design , Dual Tone 3 Seater Sofa Arrangement Customised Design , Dual Tone 2 Seater Sofa Arrangement Customised Design , Italian Top Marble Top Centre Table Of Size 4X2 Ft With Bottom Duco Finish , Customised Design Wallpaper Work On The Wall For Beautification Of The Entire Attire For An Area Of 385 Sqft , Tv Paneling With Back Frame Of 18Mm , Artifacts On Wall With Mural Design For Officers Recreation Room , Transparent Fibre Base Flower Pots With Lighting Option From Inside Of Ht 24 With Decorative , Glass Cabinet For Keeping Gifts And Trophies Of Size 6X4X1.5 Ft , Customised Design Ceiling Work With Pvc And Gypsum Board In The Corner , Romand Fabric Design Blinds With Metal Frame , Toughened Glass Door Of Size 78X45 Inch With Wooden Frame On 3 Side , Dual Tone 5 Seater Sofa Set With 1 Italing Marble Baed Teapoy , Tv Paneling With Back Frame Of 18Mm Water Proof Marine Grade Plywood , Customised Design Wallpaper Work On The Wall For Beautification Of The Entire Attire For An Area Of 120 Sqft , Artifacts On Wall With Mural Design For Co Lounge , Submarine Art Wall , Customised Design Ceiling Work With Mixture Of Gypsum Board And Pvc Material , Romand Fabric Design Blinds With Metal Frame Of Size 8 X 6 Ft , Toughened Glass Door Of Size 78 X 45 Inch With Wooden Frame , Wall Paneling With Hdhmr Sheet With Wooden Frame On Back Side With Cinc Cutting Design Submarines , Customised Design Pop Moduling Of Size 4X3.5 Ft , Cabinets With Loft With In The Pillars Of Size 10X2 Ft , Submarine Arts On Wall With Paneling Design , Cap Stand With Mirror In Centrea And 24 Brass Golden Plated Hooks , Chandellier For Officers Dinning Hall , Romand Fabric Design Blinds , Tv Paneling With Back Frame Of 18Mm Water Proof Marine Grade Plywood And Louvers , Customised Design Dual Tone 2 Seater Sofa , Playstation Panel With Backdrop Lighting With Neon Light , Artifacts On Wall With Mural Design For Officers Ante Room , Chandellier For Officers Ante Room , Toughened Glass Door Of Size 78X45 Inch With Wooden Frame On 3 Side Both Inside And Outside , Romand Fabric Design Blinds With Metal Frame Of Size 8X6 Ft Total Quantity : 99
Contract Date: Ref. Documents Contract Value : 46.09 Lakh
Government Departments No of Bidders 9
Andhra Pradesh View Result →
Contract Date: Jun 08, 2026 Contract Value : 31.46 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 7.95 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 63,626
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Jun 04, 2026 Contract Value : 12.62 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
44.
Textiles #11228400 Price Bid
Tender for Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Dismantling Cement Asbestos Celotex Or Other Ceiling Or Partition Hard Broad Wall Including Stacking Of Serviceable Materials And Disposal Of Unserviceable Materials Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead A.Of Area 3 Sq.M. And Below , Clearing Debris Includes Civil/Elect Items From Site And Disposing The Debris 10Km Away From The Site Including Loading Unloading Labour Charges And Clearing The Site Good For Work Etc.Complete , Providing And Fixing Of Double Leaf Door With Cnc Cutting As Per Design Made In -20Mm Plywood With 3Mm Thick Veneer Using Ss Pvd Coated T Patties And Pu Paint And Melamine Polish Using Ply Of Century Or Equivalent Brand Including All Necessary Hettic Soft Closing Fittings Etc. Complete , Providing And Fixing Of Single Leaf Door Made In -12Mm Plywood With 3Mm Thick Veneer Using Ss Pvd Coated T Patties And Pu Paint And Melamine Polish Using Ply Of Century Or Equivalent Brand Including All Necessary Fittings Etc. Complete , Providing And Fixing Of Partition Board Paneling With Aluminium Frame Work Of Section Size 50Mmx25mm Vertically And Horizontally At 600Mm C/C With 12Mm Thick Plywood, Top With 3Mm Thick Veneer Sheet And Using Ss Pvd Coated T Patties And Pu Paint And Melamine Polish For Smooth Finish, Using Century Ply Or Equivalent Brand For Panelling And Fixing With Necessary Screwing And Supports Etc.Complete , Supplying Of Fire Sensor / Smoke Detector-10Nos / Existing Sprinker Replacement / Relocation / Wiring / Hooter Panel Etc , Providing And Fixing Vitrified Double Glazed Finished Of 10Mm Thick Tiles Of Size 8Ft X 4Ft In Floor, Treads Or Riser Of Steps, Landing On 25Mm Thick Bed Of Cement Mortar 1:3 And Jointed With Cement Slurry Filling Tile Joints With Matching Pigment And Make Of Of Kajariya/ Simpolo Of Any Colour As Specfied By Engineer In Charge Etc.Complete. , Proving And Fixing False Ceiling Of 1.5Mm Thick Aluminium Powder / Anodised / Painted / Coated -Profiled Panels Mounted On Ms/ Gi Frames For Support And Painted / Powder Coated Chanels / With Provision For Ac Trap, Door And Light Fixing,As Per Engineer Incharge Etc.Complete , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) C. In Beams, Suspended Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases Upto Floor Five Level , Supplying And Fixing Of Window / Roller Blind Made In100% Polyster Fabric Design Plain And Colour As Per Engineer In Charge , Providing And Fixing Of 3+2+1+1 Seater Sofa Set Made In Sal Wood Frame With High Density Foam As Design As Per Drawing And Engineer In Charge , Supplying And Fixing Of Designer Artifacts Showpiece Design As Per Drawing And Engineer In Charge , Supplying And Fixing Of Nylon Based Carpet 5 Mm Thickness With Backing Design As Per Drawing And Engineer In Charge , Supply And Placing In Position Artificial Planters With Ceramic Pots Etc Complete As Shown In The Drawing And As Directed Engineer Incharge. , Design & Supply Of Signages Made From 2Mm Thick External Grade Acp Sheet Of Size (Wall Mounted) With High Grade Plotter-Cut/Cnc-Cut Vinyl & Auto-Glow Vinyl Pasted Lacquering Of Letters/Pictogram On Front Side Of The Plate, Of Varying Colours As Per Detail Drawing And Engineer In Charge. , Supplying And Fixing Of Pa - Speaker Wiring With 6Nos Ceiling Mount Speaker To Be Connected To Existing Pa System Including Cabling ,Fittings Accessceries And Necessary Supports Etc Complete. , Supplying And Fixing Of Light Fittings Of Make -Hybac /Haffle /Phillips / Panasonic/ Anchor/ Wipro / - 7W/9W/12W/20W - Panel / Cob , Supplying And Fixing Of Decorative Lights Including Wiring ,Fittings Accessceries And Necessary Supports And Installation Charges Etc Complete , Pvc Insulated Copper Wires 10 Pair 0.5 Sq.Mm Copper Conductor Frls Pvc Insulated Unarmoured Indoor Type Telephone Copper Cable , Supplying Of 20 Mm Dia Isi Marked Steel Condict With Wall Thickness 1.6 Mm , Supplying Input/Output Rj-45 Connector-Cat B , Supplying Sp Mcb, 6 A To 32 A, 10 Ka, B Series, Cat A , Supplying Of Perforted Gi Cable Tray Cross Members 1000 Mm Width X 75 Mm Depth X 2.00 Mm Thick , Supplying Of 12 Watt Cob - Brand Panasonic, Wipro, Philips Etc Complete , Supplying Of 7 Watt Cob - Brand Panasonic, Wipro, Philips Etc Complete , Supplying Of Strip Light 24O Led - Etc Complete. , Supplying Of Cove Light - Brand Etc Complete. , Electrical Labour Fitting Charges Which Includes Laying Of Cables/ Condut Pipes For Fixing Of All Fixtures And Fittings Like Light/Mcb/Schindlers Etc Complete. , Supplying Of Cendilier Designer Type For Passgae Area As Per The Design Selected , Unarmoured Pvc/Xlpe 1100 V Cable 2 Core 2.5 Sq.Mm Copper , Armoured Pvc/Xlpe 1100 V Cable 2 Core 2.5 Sq.Mm Copper , Daikin 5.3 Tr High Static Ductable Ac Supply (Model: Fxmq170nve6) , Daikin 3.2 Tr High Static Ductable Ac Supply (Model: Fxmq80pbv36) , Daikin 10Hp Vrv X Odu Unit Supply Model -Rxq10ary6 , Supply Of Refnets , Wired Remote And Receiver Kit , 0.9 Tr Daikin Split Ac Model - , Installation Testing And Commissioning Of Vrv 10Hp Odu Unit. , Installation Testing And Commissioning Of Indoor Unit. (Installation Of Ductable Ac) , Installation Testing And Commissioning Of Indoor Unit.(Installation Of Split Ac) , Supply And Fixing Of Pvc Drain Water Piping With 6Mm Thick Nitrile Rubber Insulation Complete With Fittings (Elbows, Tees, Reducers, U-Traps, Sockets Etc As Required) And Any Other Item Required To Make The System Complete. Nominal Diameters In Mm As Indicated Below. 32 Mm , Supply, Installation, Testing & Commissioning Of Refrigerant Copper Pipe Suitable For Vrv System With R32 Gas & Having Guage Thickness And Inner Dia As Below. Piping Should Be Insulated With Nitrile Rubber Foam Tube Type Sleves And Insulating On Provided Copper Pipes Having 13Mm / 19 Mmthickness, , Threading Rod & Indoor Kit , Supply And Laying With Pvc Conduit, Of 1 Sqmm / 2C, Communication Cable For Vrv Units , Supply & Charging Of Additional Refrigent Gas R 410A (If Required) , Perforated Gi Cable Tray 450 Mm Width X 50 Mm Depth X 2.0 Mm Thick , Supply And Installation Of 24Gi Duct , 13Mm Insulation , Supply And Installation Of Round Diffuser With Damper , Supply And Installation Of Return Grill , Supply And Installation Of Canvas Connection , N Odu Fabrication Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
48.
Defence #11213485 AOC
Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon.; 1 Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering all as specified and directed. 2 Dismantling timber in fillets rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work 3 S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 4 S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Eaves boards, fixed with self tapping screws as specified 5 S & F Rolled Mild Steelroof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete. 6 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering.doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening andfixing complete (Eaves board fixing ) 7 S & F 6mm thick asbestos cement plain building boards fixed to steel frameowrk with screws all as specified and directed ( For Eaves Board). 8 S &F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-w (Gde E-250 quality A) all as specified and directed. 9 M & L for Preparation of newsteel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paintover red oxide primer for material and labour complete all as specified. 10 M & LPCC B1 1:2:4 (12.5mm graded aggregate) for in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. (Note :- Bed boxes and Coping on wall to fill up the gap) 11 Demolition of Brickwork or stone/boulder masonry/PCC bloack masanory,built in cement motar all as specified and directed. 12 S & F brick work with fly ash bricks,straight or cuved on plan exc 6m mean radius built in CM 1:4all as specified and directed. (Note : 1. For filling the Gap between sheet and wall 2. Clsoing of ventilaots ) 13 Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge 14 Material and labour for suspended false ceiling usinganodized aluminum snap grid frame work.Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete. Perforated particle board/tiles for insulation and acoustic purposes, 60 x 60 cm size, fixed on snap grid 12mm thick confirming to IS 2095, 2995 Part I fixed with 25mm dry wall screws @ 230 mm C/C with screw driver to match surface attachment. Finally board have to be joined and finished to have a flush look using jointing compound/tape as per manufacturer instruction. With Designing as per direction in two steps complete all as specified and directed by Engineer in Charge. 15 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:4and is to be finished even and smooth with out using extra cement complete all asspecified directed 16 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 17 M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed. 18 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out hard dense soil 19 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting poin 20 Hard coare of broken stone aggregate, of gauge n.exc 60 mm 21 M&L for cement concrete Type D -2 1:4:8 (40 mm graded agg) in foundation fillig/path and mass concrete 22 Formwork to sides of flat concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter 23 M&L Forming Contraction (Dummy) joints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade A in plinth protection 24 Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) 25 S &F 605 x 605 mm Anodised aluminium snap grid frame work for false ceiling all as specified 26 Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified 27 Dismantling boarding, any description, fixed in any position with nail 28 Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete 29 M&L rendering 15mm thick on surface of concrete surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 30 Demolition of stone / block masonry built in CM 1:4 31 M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) and set in CM (1:6). 32 Preparing new wall surface, providing and applyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of oil emulsion 33 Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners withholdfasts and brackets, complete 34 S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 35 S&F Sheet glass 5.5 mm thick ordinary quality and glazing fixedin aluminium doors squareexc 0.5 sq. m in each pane 36 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers 37 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 38 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats 39 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) 40 M & L for 100mm thick PCC type B-2 (1:2:4) using 40mm graded aggbnas in flooring finshed even and smooth w/o using extra cement. 41 M & L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded agg finished even and smooth w/o using extr cement. 42 M & L for nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectamgular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors (Superior/ Premium quality), set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15mm thick screed bed in CM (1:6) complete all specified and directed. 43 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in Charge. 44 M & L fire resistant paint on steel surface over a coat of primer complete alll as specified (Note: The primer is of same material of 1:1 dilution application) 45 S & F of mineral fibre reinforced false ceiling tiles (all height)of size 595X595 mm of approved texture, design and pattern. The tiles should have humidity risistance RH of 99%, Light resistance greater than 85% , thermal conductivity K=0.052-0.057 W/mK, Fire performnce As per (BS476 Pt-6&7) in true horizontallevel suspended on interlocking T-grid of hot dipped all around ganvanisedIron Section of 0.33mm thick (galvanised @ 120GSM)bcomprising of main T runner of 15 X32 mm of length 3000mm, cross T of size 15X32 mm of length 600mm to form grid module of size 600X600 mm suspended from ceiling using galvanised Mild steel item ( galvanised @ 80GSM) 50mm long 8mm outer dia M-6 Dash Fastner, 6mm diameter fully threaded hanger rod upto 1000mm length and L-shped level adjuster of size 85X25X2mm, spaced at 1200 mm center to center along main T, the system should rest on perpfery walls/ partition with the help of GI perimeter wall angle of size 24X24X300mm made of 0.40mm thick sheet, to be fixed to the wall with the help of the plastic rawl plug at 450mm center to center & 40mm long drywall S.S screws. The exposed bottom portion of all y- Sectionused in false ceiling support system shall be prepainted with polyster baked paints, for sll heigth. the work shall be carried outas per specification drawing adn as per the direction of the Engr-in-charge with 16mm thick Bevelled traingular Mineral Fibre faalse ceiling (NRC 0.5 to 0.6)) 46 Taking down and of chowkats or frames exc 1.5 sqm n exc 4 sqm each 47 S & F Anodised aluminium frame powder coated to (minimun thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 48 S & F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,ruber neoprene packing, handk=les 2 Nos in each door, hinges, anodises aluminium snap beading screws etc. complete all as specified. 49 Cuting holes exc 150 sqcm but not exc 400 Sqcm into or through brick walls built in cement mortar of any description and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-I as required 50 m&L two coats or Oil Bound distemper on Cement concrete surface over a coat of primer as per the shed directed by the engineer-ncharge, complete all as specified. 51 M&L for treating small articles such as ends of posts, holdfasts etc with tar or coal tar black paint; area exc 0.1 Sqm but n exc 0.5 Sqm each 52 S&F sheet in repairs glass 4.8 mm thick exc 0.5 sqm area ordinary quality and glazing with oil putty/rubber gasket fittings all as specified and directed. 53 M & L in repairs for 12mm Prelaminated particle board, interior grade, prilaminated both side with decorative choice lamination fixed with screws to timber/Aluminium frame work complete all as specified and directed. 54 S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I 55 S & F in repairs 20 mmBrass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed 56 S&Fbib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap). 57 S&F GI tubingof 15 mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 58 S&F GI tubingof 20mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 59 S&F GI tubingof 25mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 60 S&F25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 61 S&F20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 62 Dismantling wrought iron or mild steel work of any description not otherwise provided for. 63 S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 all as specified and directed.(Eaves Baords) 64 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 65 Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed 66 M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified 67 M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified 68 M&L for reinforced cement concrete M 20 using 20mm crushed stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. 69 M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. 70 M&L for preperation of new concrete /plastered surface of any description, two coat of plastic emulsion paint over a coat of primer complete all as specified and as directed complete all as specified and as directed. 71 M&L for Powder Coated (Minimum thickness of powdercoating 50 micron)Anodised aluminium frame of standerd section for doors, windows, ventilators and partitions withdoublerebates including joining cleat for fixing etc. complete all as specified 72 S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (For sliding window ) 73 M&L sheet glass 4.0mm thick figured glass, pin head type and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed 74 M&L for vetrified ceramic tiles 10mm thick full body(Dark shade/Ultra Charged/Double charged ) (square/rectangular) polished, area of each tilesexc 1.00 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 75 M&L for vetrified ceramic tiles 10mm thick full body(lightshade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 76 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediatechannel at 457 mm centre to centre and including Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified 77 S&F for 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish(Frame work for ceiling shall be measured and paid separately) 78 Removal of existing Rifle racks including all fixing stell bolts and cement work all as specified work 79 M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified 80 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 81 M & L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. 82 M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 83 M&L for machine cut mirror polish kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 84 Fixing and grouting of new steel Rifle racks on the floor including necessary fixing bolts and necessary arrangements of grouting and grouting material all as specified. 85 M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 86 S&F for Mild steel ,plain black sheet of minimum 0.8mm thickness for Hoods cover for Rolling shutters;cladding to door shutters/Hangar doors ; water tank platforms etc with plain 40mm lap joints or welded/riveted seams including ,bending, turning up, mitred angles , stopped ends,outlets,etc. as required all as sprcified and directed by Engr-in Charge. 87 M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. 88 Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. including sorting out serviceable and unserviceable light fitting and keep serviceable fitting in safe guard for reuse as required on site. 89 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 90 Taking down cearfully byunscrewingthe unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts etc all as directed. 91 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and capingwith all fittings/fixture etc andsurface typePVC box, cover plate all as specified and directed by Engr-In-Charge.(a) Onelight point controlled by one switch. 92 (b) One 3 pin socket 5 A on independent board. 93 (c) One 3 pin socket 5 A on same board. 94 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,with all fittings/fixture etc andsurface typeModular , PVC box cover plate, frame all as specified and ndirected by Engr-In-Charge. 95 S & F Sub Main Wiringwith FRLS PVC Insulatedmultistranded copper conductorwires ofsize2x6.0 sq. mm + 1x6.0 sq. mm earth wire in casing caping complete as directed.Note : for Item No 95 One run of phase wire one run of Neutral wire and one run of Earth wireand one run of casing and capping shall be meassured and as one length. 96 S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps.including fixing concealed in wall and making good the disturbed surfacecomplete all as directed 97 Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 98 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed 99 S&F MCB SP 240 volt 6 to 32 A C series complete 100 S &F for MCB SPN 40-63 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. 101 Supply and fix Modular switch 1 way 6A, 1 module 102 Supply and fixmodular Socket, 6A - 2/3 pin combined 2 moduler 103 Supply and fixModular switch 1 way 16A, 1 module 104 Supply and fixmodolar Socket 6A/16A - 2/3 pin combined2 module, 105 Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm 106 S & F Modular white cover plate with frame 2 Module 107 S & F Modular white cover plate with frame 3 Module 108 S & F Modular white cover plate with frame4 Module 109 S & F Modular white cover plate with frame 6 Module 110 S & F Modular white cover plate with frame 8 Module 111 Supply, Fixing , Testing and Commissioning of Single phase isolation transformer to be installed at input power supply of L-2 switch,via 16 Amps MCB and with power earthing point specification as follows 1Ph, Capacity 1KVA, Input 230V AC ±10%,Output 230V±10%,50 Hz,cooper wire,work efficiency more than 95%,potential between earth to neutral less than 1 Volt with all standard fitting as per direction of Engineer in charge 112 Supply, Fixing , Testing and Commissioning ofIsolation transformer of capacity 5 KVA, single phase ,50 Hz , Copper wound , Air cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 240+-5% and output voltage range 240+-5% ,Ratio 1:1 , indoor , efficiency more than 95 % , Potential difference between neutral to earth less than one volt with all standard fittingsas per direction of Engineer in charge 113 Supply, Fixing , Testing and Commissioningof Three Phase Surge Protector Device to be installed at input power supply of L-2 switch all as specified and directed by Engr-In-Charge 114 S&F wall mounted Industrial grade metal enclosure box made from 3mm thick CRCA sheet consist of following Items:-(a) Panel mounting Industrial grade socket/plug outlet 16 A,IP44(b) SPD ,1.5kv,320A,20kA - 1 Nos(c ) MCB SP 16 A- 1 Nos 115 S&F Vertical double door Distribution board TPN 4 way 125 A rated busbarconsisting ofMCCB. 63 A 18KA - 1 Noincluding fixing on wallsurface and making good the disturbed surfacemaking all nacessary incomming and out going connections using proper size copper thimblescompleteall as required on site all as directed 116 Supply and fixing in replacement sheet metal enclosure with DBs ( grouted in walls) double door type for MCBs 12 ways with 200 Amps 240 volts rated bus bar incl taking down old DB all as specified. 117 Material and labour for taking down serviceable Fire Alarm panel from one location and re-install the same at same /another location including fixing brackets/nut bolts incl testing and commessioning of the same all as specified and directed 118 Material and labour for taking down serviceable Smoke / Heat / Fire detector from one location and re-install the same at same /another location including necessery cable upto Fire alarm panelincl testing and commessioning of the same all as specified and directed 119 Supply and fix adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 all as specified. 120 Supply, install, testing and comissioning of adessable break glass manual call pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. 121 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade. 122 Material and labour for taking down serviceable split AC of capaicty upto 2.0 TR from one location and re-install the same at same /another another location including fixing brackets, gas charging, brazing and additional required copper piping incl testing and commessioning of the same all as specified and directed 123 Supply, Install testing and commessioning Single pole and neutral enclosure 240 Volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed 124 Material and labour for providing point wiring with two runs of 4 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,ISI Marked complet for housing one 15 to 20 A Switch / socketscomplete 125 Supply, Install , Testing and Commissioning of wall mounted enclosure box made from 3mm thick CRCA sheet enclosure consist of following items for 3 Phase 2 AC timer & Controller of Auto switching timer unit suitable for operate 8.75 TR package type AC:-(a) Timer - 1 No(b) Contactor 32 amps - 2 No(c ) Indication lamp - 1 No
Contract Date: Jan 09, 2026 Contract Value : 44.46 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
49.
Housing Urban and Rular Development #11202911 Technical Bid
Tender for Dismantling Stone Slab/ Terrazo Chip Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead:For Thickness Of Tiles 10Mm To 25Mm. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.1: 4: 8 Or Leaner Mix. , Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level.M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :25 Mm Thick , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar).Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. , Providing And Fixing Of Wall Paneling On Grid Made Out Of Pvc Profile Section Of Size 21X17mm With A Wall Thickness Of 1.5Mm+/-0.2Mm,Fixed On The Existing Wall With Wood Screw Of Size 50Mm X 8Mm With Rowel Plug At A Spacing Of 900Mm Center.Upvc Profile Section Of Size 150Mm X 10Mm With A Wall Thickness Of 1.0Mm+/-0.2Mm To Be Fixed On The Grid By Self Tapping Screw Of Size 19Mm X 6Mm.Necessary Cutouts For Electrical Connection To Be Provided At Required Places. The Edge And Periphery, Finally To Be Covered By Extruded Pvc Beading Section Of Size 28Mm X 12Mm With A Wall Thickness Of 1.0Mm+/-0.2Mm Complete As Per ManufactureS Specification And Direction Of Engineer-In-Charge. , Providing Solid Pvc False Ceiling Consisting Of 600Mm X 600Mm, 5Mm (±0.25) Thick Plain Embossed Pvc Sheet Of Density 600 Kg /Cbm Manufactured By An Iso-9001-2015 Certified Company, Used As Panel Insert In A Frame Work Made Using Powder Coated Aluminum T- Section Of Sizes 1 X1( 25X25mm, 19 Gauge Or 1Mm Thick ) In Square Pattern Of Grid Sizes Of 2X2( 600X600mm ). The Aluminum Framework Is Supported From The Ceiling With The Help Of J Hook And G.I. Wire / 6Mm M.S. Rods Of Required Sizes To Maintain Proper Level Etc. The Aluminum Framework Is Supported On Side Wall With The Use Of Aluminum L-Section Of Size 1X1 ( 25X25mm ) Angles Etc. Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : , Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged :Style / Rail Of Teak Wood 30Mm Thick/ Aluminium Section,4Wide , Providing And Fixing S.S. Rod 30Mm Dia (304 Grade ,16Swg) Including Brackets Fixed With C.P. Brass Screws And Rawl Plugs, Etc., Wherever Necessary Complete Two Side Central All Fittings. , Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.2.0Mm Thick (Wt. 3.3 Kg./Mtr. Sq.) , Providing & Fixing Commercial Ply As Per Is 710 : 1976 Bwr Of Approved Make For Making Wardrobe/Shelves And Other Furniture With Fevicol & Nails Complete As Per Approved By Engineer In Charge.6 Mm Thick , Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Is : 3564 Marked Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer With Necessary Accessories And Screws Etc. Complete. , P & F Pilllar Cocks (Is :8931 : 1993 Mark) Of Superior Quality And Approved Make:C.P. Pillar Cock, 15 Mm Dia Nominal Bore , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150Mm Distance. , Making Holes In Stone Masonry Wall Upto 450 Mm X 450 Mm Size And Making Good In Cm 1:6. , Rough Chisel Dressed Sand Stone 35 Mm Thick Flooring Of Approved Shade Set Over 20Mm Thick Base Of Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) And Pointing With Cement Sand Mortar 1:3 With Pigment To Match The Shade Of Stone With Joint Thickness Up To 15 Mm Complete In All Respects : , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges :Kota Stone Minimum 30Mm Thick. , Providing And Fixing Concertina Coil Fencing With Required Dia 610 Mm (Having 15 Nos. Round Per 6 Metre Length) Up To 3M Height Of Wall With Existing Angle Iron Y Shaped Placed 2.4 M Or 3.00 M Apart And With 9 Horizontal R.B.T. Stud Tied With Gi Staples And Gi Clips To Retain Horizontal Including Necessary Bolts Or Gi Barbed Wire Tied To Angle Iron All Complete As Per Direction Of Engineer In Charge With Reinforced Barbed Tape (R.B.T.)/Spring Core(2.5 Mm Thick) Wire Of High Tensile Strength Of 165 Kg/Sq.Mm With Tape (0.52 Mm Thick) And Weight 43.478 Gm/Metre (Cost Of Ms Angle, Cement Concrete Block Shall Be Paid Extra) , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Whenever Required.0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/M2 , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. , Providing & Fixing Premium Quality Toilet Corner Glass Shelf Size 225X225mm With C.P. Brass Brackets & Guard Rail Edges Rounded Of Ss Frame , Providing And Fixing 18 Mm Thick, 150 Mm Wide Pelmet Of Flat Pressed 3 Layer Or Graded Wood Particle Board Medium Density Grade I, Is : 3087 Marked Including Top Cover Of 6 Mm Commercial Ply Wood Conforming To Is: 303 Bwr Grade, Nickel Plate Ms 20 Mm Dia Curtain Rod With Nickel Plated Bracket Including Fixing With 25X3 Mm Ms Flat 10 Cm Long All Complete , Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. , Repair To Brick Masonary In Cement Sand Mortar 1:6 With New Brick. , Repair Of Existing Steel Glazed Doors, Windows And Ventilator, Ms Sheet Door, Garge Doors, Compound Wall Gates Etc. By Welding Drilling Complete Include. Cost Of Welding Rods And Hire Charge Of Welding Meachine And Tp Etc Complete , P & F Lst Quality Wvc Urinal (Is:2556 Mark) With 25Mm Dia G.I. Waste Pipe, Dome Waste Couplings, Concealed Iron Brackets Or Screws Etc Complete.Flat Back (Small) Size 456X355x265mm. , Mechanised Cleaning Of Sewer Line Of Diameter Upto 200Mm With The Help Of Trolley Mounted Electrical Driven Machine Having Flexible Steel Springs Of Length 20Ft. Each Which Are Rotated With The Help Of Electric Motor And Clutch Assembly. , Providing And Fixing Welded Mesh/Expanded Metal Mesh In Frame Work, Flat Iron Beading 20X3mm Including Top Cross Laps Inside And Out Sides Welding, Iron Bolts, Crews, Clips Etc. Complete (Excluding Frame Work) Of Size. 9.38.3 Welded Mesh 25 Mmx 25 Mm X 2.1 Mm , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 4 Mm , Labour Charges For Removing & Refixing The Water Storage Each Tank Of All Sizes And Including All Necessary Fitting Complete In All Respect As Per Approved Sample And Direction Of Engineer In Charge. , Repair To Damaged Reinforced Cement Concrete Slabs, Beams And Columns Etc For Sqm Strengthening With Cement Mortar 1 : 2 In Following Steps :- (I) Choping Losse And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Papering , Cleaning Of Concrete Surface With Water As Necessary And Getting Dried. (Ii) Applying Epoxy Primer On The Exposed Steel Bars. (Iii) Applying Epoxy Hardener And Resin Mix (As Per Manufectureds Specification) On Concrete And Steel Bars With Brush. (Iv) Speading Dry Cement Mortar 1 : 2 Mix Over Epoxy Treated Wet Surface And Allow It To Dry For One Day. (V) Plastering The Surface With Cement Sand Mortar 1 : 3 Upto Depth Of 30Mm Complete. (Vi) Cure The Plastered Surface For 15 Days, All Work Including Scaffolding Etc. Complete In All Respect.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
50.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
TenderDetail
Loading tenders