View Bid Results For Ultrasonic Level Transmitter Tenders

We found 300 Bid Results related to ultrasonic level transmitter tenders. You can find Contractor details who won ultrasonic level transmitter tenders along with contract details in Bid awards announcements section.

Filters
Stage
260
27
13
Tender Publishing Platform
173
127
State / UT
21
49
31
31
24
23
22
19
18
14
9
9
8
8
7
6
6
4
4
4
3
1
Contract Value
60
154
68
16
Publish Date
0
0
0
0
0
Sector
19
55
47
33
33
23
19
16
12
10
8
8
8
8
6
6
4
2
1
1
Ownership
6
174
73
27
20
4
2
Within keyword
Active filters:
Showing 1–6 of 300 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 1.00 Lakh
Government Departments No of Bidders 6
Contract Date: Ref. Documents Contract Value : 4.40 Lakh
Boards / Undertakings / PSU No of Bidders 7
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 61,360
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : 9.37 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : 3.60 Lakh
Boards / Undertakings / PSU No of Bidders 5
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 59.06 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 3.11 Lakh
Boards / Undertakings / PSU No of Bidders 10
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 2.57 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
9.
Power #10898930 AOC
Bids Are invited for Ultr Snr Lt Rnge 5 Mtr - Non Contact Ultrasonic Sensor Type Level Transmitter Range 5.0 Mtr Model No Uc551-P-C-B-D-N-A Protection Ip 67 ,4-20Ma -Hart - 15-30Vdc - 2 Wire Temperature - Pressure -40 To 80 Degree Celsius -0.2 To 1 Bar Conn. Flanged Type Make Bm Tecnologie , Level Transmitter 0-10 Meter - Level Transmitter Range 10 Meter ,Non Contact Ultrasonic Level Transmitter Model No- Uc 552-P-C-B-D-N-A, Protection -Ip 67 Electonics 4-20 Ma - Hart - 15-36 Vdc 2 Wire Temperature - Pressure -40 To 80 Degree Celsius -0.2 To 1Bar Make Bm Tecnologie , Ultr Snr Lt,Ru Rnge 0-10Mtr - Non Contact Ultrasonic Sensor Type Level Transmitter Range 10.0 Mtr Model No Uc552-Ru-C-B-D-N-A,Flp-Wp Enclosure For Hazardous Zone Uc 55X Series Protection Ip 67 ,4-20Ma -Hart- 15-36Vdc - 2 Wire Temperature - Pressure -40 To 80 Degree Celsius -0.2 To 1 Bar Co N. Flanged Type Make Bm Tecnologie , Ultr Flam Proof L T Rng 20 Mtr - Contact Ultrasonic Sensor Type Level Transmitter Range 20.0 Mtr Model No Uc553-Ru-A-Fl-B-D-N-A,Flp-Wp Enclosure For Hazardous Zone Uc 55X Series Protection Ip 67 ,4-20Ma - Hart - 15-36Vdc - 2 Wire Temperature - Pressure -40 To 80 Degree Celsius -0.2 To 1 Bar Con . Flan Ged Type Make Bm Tecnologie , Ultr Flam Proof L T Range 20 Mtr - Contact Ultrasonic Sensor Type Level Transmitter Range 20.0 Mtr Model No Uc553-Ru-A-Fl-B-D-N-A,Flp-Wp Enclosure For Hazardous Zone Uc 55X Series Protection Ip 67 ,4-20Ma - Hart - 15-36Vdc - 2 Wire Temperature - Pressure -40 To 80 Degree Celsius -0.2 To 1 Bar Con . Flan Ged Type Make Bm Tecnologie Total Quantity : 15
Contract Date: Ref. Documents Contract Value : 12.99 Lakh
Boards / Undertakings / PSU No of Bidders 1
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.09 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
13.
Water Resources and Irrigation #10512078 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation, Furnishing Of Existing Barrage Control Room At Gaula, Barrage, Haldwani, Uttarakhand Under National Hydrolog , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification. , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Gaula Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimumone Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
14.
Water Resources and Irrigation #10512072 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification, Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Under National Hydrology Project , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Condition System With Requisite Furniture And Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification Located At Adwa Barrage, Mirzapur , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Ramnagar Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimum One Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
15.
Educational and Research Institute #10510174 Price Bid
Tender For Tinkering Lab Equipments Purchase And Lab Installation , Electronics Development , Arduinouno Or Equivalent , Arduino Nano Or Equivalent , Arduino Mega Or Equivalent , Raspberrypi3 Model B+ , Breadboards &Mini Breadboard , General Purpose Solderable Board , General Purpose Solderable Board , Berg Strips , 16X2 Lcd Display , Usb Cables , Usb Cables , Battery , Resistor Kit , Capacitor Kit , Linear Voltage Regulator , Water Pump Module , Piezoelectric Plate , 8*8 Led Matrix Module , Bluetooth Module , 7 Segment Led Display , Gsm , Gps , Laser Diode Emitter , Ldr Module , Keypad , Joystick , Active Buzzer , Motor Drive Module , Sound Playback Module , Dcplastic Gear Motor With Wheel , Node Mcu , Wemosd1r2 , Vibrating Motor , Alligator Connectors , Battery Clips With Dc Jack , Hook-Up Wires , Jumper Cable , Rgb Leds , Rgb Leds ( Red ) , Rgb Leds ( Green ) , Rgb Leds ( Blue ) , Rgb Leds ( Yellow ) , Rgb Leds ( White ) , Timer Ic-Lm 555 , Atmega16u2 , Diodes And Transistors Kit , Button Switch Set , Capacitative Touch Switch Module , Ir Sensors, Obstacle Avoider Sensormodule , Internet Of Things & Sensors , Triple Axis Magnetometer , Humidity Sensor , Mq Series , Ir Transmitter / Receiver , Ultrasonic Sensor Module Hc-Sr-04 Or Compatible , Triple Axis Accelerometer , Pir Motion Detector Module , Pulse Rate Heart Sensor , Rely Module , Big Sound Microphone Module , Soil Moisture Sensor Module , Touch Sensor , Metal Touch Sensor Module , Rain Drop Sensor , Flex Sensor , Temperature Sensor , Force Pressure Sensor , Colour Recognition Sensor , Water Flow Sensor , Sound Sensor , Ir Sensor Array Module For Line Following , Power Bank , Rfid Reader Tags , Rfmodulestx & Rx 315 Mhz Ask , Robotics , Stepper Motor With Driver Board , Dc Motor , Servo Motors , 150 Rpm Bo Motor , L298p Motor Driver , Servo Motor Tester , Diy Kit , Robotics Diy Kit , Mechanical ( Modular ) Construction Kit , Stem Learning / Application Kit , Drone Kit , Aerospace Kit , Automobile Kit , Bio Medical Kit , Agri-Tech Kit , Water / Sanitation Kit , Bio Tech Kit , Other Potential Stem Application Kit , Package 2 Rapid Prototyping Tools , 3D Printer Kit And Tools , Dedicated Ups / Power Back Up , Filament For 3D Printer , Filament Storage Box , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material--Cardboard , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material--Foam Core Boards , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- 20 M Spool Of Thick Strings Various Colours , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- Rubber Band , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- Popsicle Sticks , Set Of Arts & Crafts Accessories- E.G. -Stationary Items And Basic Prototyping Material- Wood Glue- 500 Ml , Package 3: Mechanical, Electrical And Measurement Tools , Hacksaw Frame , Hacksaw Blades , Mini Hacksaw Frame , Mini Hacksaw Blades , Pliers: 4.5 Inch Size--External Straight , Pliers: 4.5 Inch Size--Nose Circlip Plier , Pliers: 4.5 Inch Size--Long Nose Plier , Pliers: 4.5 Inch Size--Combination Mini Plier , Pliers: 4.5 Inch Size--Wire Stripping Pliers , Pliers: 4.5 Inch Size--Bent Nose Plier , Pliers: 4.5 Inch Size--Needle Nose Pliers , Tweezer Set , Ball Pin Hammer , Steel Shaft Claw Hammer , C- Clamp , Allen Key Set , Drill Machine Set , Drilling Workstation , Spanner Set , Vice Normal , Precision Screw Driver Set , Wrench , Wire Strippers , Screwdriver , Cordless Rotary Multi-Tool Set , Air Blower , Drill Bit Set , File Set , Mini File Set , Flexible Cutting Mat , Plastic Storage Drawer / Organiser , Pegboard , Electric Tools , Hot Glue Gun , Digital Oscilloscope , Soldering Kit , Adapters , Adapters , Electric Screw Driver Set , Dual Temperature Heat Gun , Soldering Helping Hand , Measurement Tools , Return Measuring Tape , Stainless Steel Rule , Digital Vernier Calliper , Spirit Level , Digital Pen Electric Tester , Digital Multi Meter , Biology Kit , , Diy Papermicroscope , Astronomy Equipment , Telescope, , Textileequipment, Sewing Kit , Package 4 : Power Supply & Accessories And Safety Equipment , Glue Sticks , Nuts And Bolts And Screw , Cable Tie- Pack Of 100 , Sand Paper , Power Strip Adaptors-5M , Bulb Holders , Electric Wires , Usb To Dc Jack Cable , First Aid Kit , Fire Extinguisher ( Handy Units ) , Safety Goggles [ With / With Out Led Torch ] , Safety Glove , Safety Mask , Projector Setup , Lap Top , Projector , Projector Screen , Electronics Development , Power Plug , Plugs , Ac Plug , Mcb 16A Switch , Mcb 20A Switch , Mcb 10A Switch , Elcb , Fan , Tube , Wires , Furniture , Executive Chair , Executive Table , Table , Stool , Chair , Almirah , Painting , Rooms , Door , Windows , Curtains , Window Blinds Curtain
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
16.
Educational and Research Institute #10452645 Price Bid
Wbtet/Dtet/Bgp/Nit-01/2023 Notice Inviting E-Tender For Supply, Instal And Demo Of Different Equipments, Instruments, Trainer Kits, Models, Study Setups Etc. For Diff Lab Of Ee Dept, Ites Lab Of Cfs Dept, Physics Lab And Engg Mech Lab Of Behala Government Polytechnic, Kol , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Single Purchase Crab Winch , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Double Purchase Crab Winch , Worm And Wheel Apparatus , Wheel And Differential Axle Unit , Simple Screw Jack Unit. , Setup To Determine Coefficient Of Friction , Universal Force Table. , Digital Spring Balance , Analytical Weight Box , Slotted Weights With Hanger, For Laboratory , Convex Mirror , Concave Mirror , Plane Glass Slab , Moment Of Inertia Of A Flywheel. , Co-Efficient Of Linear Expansion Of A Metal Rod. , Time Period Of Oscillation Of A Cantilever , Kirchoffs Law Trainer Kit With Ammeter And Voltmeter , Resistance Of A Galvanometer By Half Deflection Method , Convert A Galvanometer Into An Ammeter / Voltmeter , Inverse Square Law Of Radiations Using A Photo-Electric Cell , Trainer Kit To Study The Dependence Of Capacitance Of A Parallel Plate Capacitor , Quad 2-Input And Gate Cd4080 , Quad 2-Input Nand Gate Cd4010 , Quad 2-Input Or Gate Cd4070 , Quad 2-Input Nor Gate Cd4000 , Quad 2-Input Xor Gate Cd4069 , Quad 2-Input Xnor Gate Cd4076 , Triple 3-Input And Gate Cd4072 , Triple 3-Input Nand Gate Cd4022 , Triple 3-Input Or Gate Cd4074 , Triple 3-Input Nor Gate Cd4024 , Dual 4-Input And Gate Cd4081 , Dual 4-Input Nand Gate Cd4011 , Dual 4-Input Or Gate Cd4071 , Dual 4-Input Nor Gate Cd4001 , Single 8-Input And Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Nand Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Or Gate Cd4078 (2 Outputs Per Gate) , Single 8-Input Nor Gate Cd4078 (2 Outputs Per Gate) , 4068 Hex Not (Inverting Buffer) , 4040 Quad Buffer/Inverter (Each Input Has 2 Outputs Q And Q) , 4049Hex Buffer , 4059 14-Bit (÷16,384) Ripple Counter With Internal Oscillator , Adc0809 8-Bit ?P Compatible A/D Converters With 8-Channel Multiplexer (Dip Package) , Dac0800 Ic - 8-Bit Digital To Analog D/A Converter Ic Dip , 4509 Up/Down Decade (0-9) Counter With Preset , 4515 Up/Down 4-Bit (0-15) Counter With Preset , 4016 Decade Counter (1-Of-10) , 4027 Bcd To Decimal (1 Of 10) Decoder , 4012 - Dual D-Type Flip-Flop With Set And Clear. , 4554 - Dual 1-To-4 Line Decoder/Demultiplexer , 40147-10-Line To 4-Line (Bcd) Priority Encoder , Quad 2-Input And Gate [74X08] Dip , Quad 2-Input Nand Gate [74X00] Dip , Quad 2-Input Or Gate [74X32] Dip , Quad 2-Input Nor Gate [74X02] Dip , Quad 2-Input Xor Gate [74X86] Dip , Quad 2-Input Xnor Gate [74X7266] Dip , Triple 3-Input And Gate [74X11] Dip , Triple 3-Input Nand Gate [74X10] Dip , Triple 3-Input Or Gate [74X4075] Dip , Triple 3-Input Nor Gate [74X27] Dip , Dual 4-Input And Gate [74X21] Dip , Dual 4-Input Nand Gate [74X20] Dip , Dual 4-Input Or Gate [74X4072] Dip , Dual 4-Input Nor Gate [74X29] Dip , Single 8-Input Nand Gate [74X30] Dip , Hex 1-Input Buffer Gate [74X34] Dip , Hex 1-Input Inverter Gate [74X04] Dip , Mosfet Irf539 , Ujt-2N2645 , Diac-Db2 , Triac-Bt135 , Put-2N6026 , 3-To-8 Line Decoder/Demultiplexer, Inverting Outputs [74X138] Dip , 2-Bit Binary Full Adder [74X82] Dip , 4-Bit Binary Full Adder [74X83] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X47] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X46] Dip , Flip Flop [74X74] Dip , And-Gated R-S Master-Slave Flip-Flops With Preset And Clear [74X71] Dip , Dual Negative-Edge-Triggered Master-Slave Complementary Outputs [74X73] Dip , Quad S-R Latches[74279A] Dip , Voltage Regulator Ic: [Lm7805] Dip , Voltage Regulator Ic: [Lm7905] Dip , Voltage Regulator Ic: [Lm7809] Dip , Voltage Regulator Ic: [Lm7909] Dip , Voltage Regulator Ic: [Lm7812] Dip , Voltage Regulator Ic: [Lm7912] Dip , Voltage Regulator Ic: [Lm7815] Dip , Voltage Regulator Ic: [Lm7915] Dip , Single Timer Ic[Lm555] Dip , Voltage Regulator[Lm723c ] Dip , Moving Iron Type A. C. Ammeter: 0-0.2/1A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-0.5/2.5A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-2/10A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-10/20A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-15/30A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter:0 -75 / 150 / 300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter: 0- 150 / 300 / 600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ua (Micro-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 0.5/1 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 5/10 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 10/20 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 500/1000 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter :0 – 1 / 2 A (Dual Range) ; Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 5 / 10Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 10 / 20Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 25 / 50 / 100 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 / 150 / 300 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 250 / 500 / 1000 Mv. (Tripplerange); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 15 / 30 / 75 V. (Tripple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 /150 /300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 150 /300 /600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 500 /1000Volts (Dual Range); Accuracy Class± 0.5% , Dynamometer Type Single Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 2.5 / 5 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 0.5 & 1Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 1 / 2Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 2.5 / 5Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Single Phase Power Factor Meter: Current Coil Range : 1 & 2 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Single Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Three Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:150/300 600 Volts ( Triple Range ).Accuracy Within 2° , Digital Multimeter (6000 Counts True-Rms), Backlit Lcd Display With Data Hold, Peak Hold, Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Digital Multimeter (20000 Counts True-Rms, 4-1/2 Digits), Backlit Lcd Display With Data Hold, Peak Hold,Auto Range,Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Microprocessor Based Fully Automatic L, C, R & Q Measurement Autocompute Lcr - Q Meter , Analog Oscilloscope: 30 Mhz, 2 - Channel,4 - Trace , 10Mhz Multi Waveform Signal/Function Generator: , Dds 20Mhz Multi Wave Form Signal Generator , Tachometer: Non-Contact Type Tachometer And Counter: , Tachometer: Contact-Type Digital Tachometer With Adaptors (60 To 49,999 Rpm) , Digital Lux Meter: , Clamp Meter : Digital Trms Ac/Dc : 3-5/6 Digit, 6000 Count, Backlight Lcd; T-Rms, Auto Ranging; Relative Measurement; Data Hold , Digital Earth Resistance Tester For 0 – 10 / 100 / 1000 Ohms, 4 Terminal With Testing Kit And Cables In A Hard Carrying Case , Digital Electronics Trainer Kit: , Electronics Trainer Kit (General Purpose): Self-Contained Capable To Perform Experiments Of Digital & Analog Electronics; , Network Theorem Trainer Board , Training Board To Determine The Power And Power Factor & To Draw Phasor Diagram In Series Rl, Rc & Rlc Circuit , Resistive Load Bank: 1 Phase / 10 A / 10 Steps / 230 V , Resistive Load Bank: 3 Phase / 10 A / 10 Steps / 415 V , Capacitive Load Bank: 1 Phase / 5 A / 230 V , Capacitive Load Bank: 3 Phase / 5 A / 230 V , Inductive Load Bank: 1 Phase / 10 A / 230 V / , Inductive Load Bank: 3 Phase / 10 A / 230 V / , Decade Capacitance Box: Range: 100 Pf To 10 Uf , Decade Resistance Box: Range: 10 Ohm To 1M Ohm , Decade Resistance Box: Range: 1 Ohm To 100K Ohm , Decade Inductance Box: Range: 100 Uh To 10 H , Regulated Dc Power Supply; Out Put : 230 V Dc - 30 A. , 3- Phase Electromagnetic Type Energy Meter , 3- Phase Digital Energy Meter , Single Phase Digital Energy Meter , Stop Watch Mechanical, , Digital Stop Watch , Kelvin Double Bridge For Low Resistance Measurement , Wheatstone Bridge For Measurement Of Medium Resistance , Digital Insulation Tester , Hand Driven Megger 1000V/500M Ohms , Earth Tester For Measurement Of Resistance Of Earth And Specific Soil Resistively , Trainer Kit For The Measurement Of Unknown Inductance Of A Coil By Anderson Bridge , Trainer Kit To Measure Unknown Capacitance Using Schering Bridge , Tri-Vector Meter 3Ph, 4Wire, 240 V, 10 - 40A , 3 Ph, 400 / 230 V, 3 Kva Transformer With All Terminals Brought Out For Different Connections. , Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test. , Parallel Operation Of Two Single Phase Transformers , Transformer 1 Kva / 230/230V With Tappings , Setup To Study Open Circuit Test Of D.C. Shunt Generator , Setup To Study Speed Control & Load Test Of Dc Shunt Motor , D.C. Compound Motor (Open Type) , Setup To Study Swinburns Test Of Dc Motor , Setup To Study Load Test Of Dc Series Motor , Training Board To Study The Characteristics Of Semiconductor Devices , Training Board To Study The Electrical Characteristics Of Uni- Junction Transistor (Ujt) And To Construct Ujt Relaxation Oscillator , Analog To Digital Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Analog Signal To Digital Signal. , Digital To Analog Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Digital Signal To Analog Signal. , Logic Training Board For The Study Of Counters & Shift Registers , Power Electronics Lab Trainer , Training Board For The Study Of Switching Mode Power Supply (Smps) For Computer , Ups (Online) Demonstration Kit , Ups Trainer Kit 500Va Offline , Autotransformer Starter , 3 Phase Induction Motor (Semi Open Type) , Setup To Study No-Load Test, Blocked Rotor Test & Load Test Of Induction Motor To Determine Different Parameters Of The Motor. , Setup To Measure The Open Circuit Voltage Ratio Of The Three-Phase Slip Ring Induction Motor And Perform The Speed Control By Insertion Of Resistance In Rotor Circuit For Slip Ring Induction Motor. , Setup To Conduct The Direct Load Test To Determine The Efficiency And Speed Regulation For Different Loads Of A Single Phase Induction Motor; Plot The Efficiency And Speed Regulation Curves With Respect To The Output Power. , Rotor Resistance Starter - 5H.P. 3-Ph, 400V (For Slip Ring Motor) , D.O.L Starter - 3H.P. 400V, 3-Ph; , Star Delta Starter - 5H.P., 3-Ph, 400V, Manual; , Star Delta Starter - 5H.P., 3-Ph, 400V, Automatic; , Variac (Autu Transformer) - Single Phase Portable Table / Floor Mounting Nclosed Input 230V A.C., Output 270V A.C., 50-60Hz, 15 Amp, Air Cooled , Variac (Autu Transformer)- Three Phase 415V A.C., Output 470V A.C., 50-60Hz, 15Amp, Air Cooled , Setup To Perform The Direct Loading Test To Determine The Regulation And Efficiency, Oc And Sc Tests (Synchronous Impedance Method), To Plot The V Curves And Inverted V Curves Of Three Phase Alternator. , Setup To Plot Current – Voltage (I-V) Characteristics Of Poly Crystalline Silicon Solar Cell And Find Out The Solar Cell Parameters. , Setup To Measure Beam, Diffuse And Global Radiation On Horizontal And Tilted Surface Using Pyranometer And Plot Radiation Vs. Time Characteristics For Certain Duration. , Setup For Characterization Of A Solar Flat Plate Collector And Evaluate Its Parameters. , Setup For Characterization Of A Solar Concentrating Collector And Evaluate Its Parameters. , Setup To Measure Thermal Performance Of A Solar Cooker With Varying Reflector. , Solar Street Lighting System For Dc Supply. , Set Up A Small Wind Turbine (Swt) System And Identify Its Specified Components. , Study Of Different Parts Of Water Turbines Such As Pelton Wheel, Francics And Kaplan. , Set Up Of A Anaerobic Digestion Biogas Plant To , Set Up For Induction Type Over Voltage / Under Voltage Or Over Current/ Under Current Relay Ckt Using Suitable Hardware Ckt Controlled By 8085 Microprocessor To Plot The Characteristics , Jumper Wire: Single Stranded, Insulated Wire(Copper) 0.5Mm Dia , Jumper Wire Cutter: Self Adjusting Cable/Wire Cutter Stripper - Automatic Stripping Tool For Cables Up To 6 Mm , Twizzer , Magnifying Glass , 3-Phase Trms Multifunction Meter For 3Phase-3Wire/3Phase-4Wire Balanced Or Unbalanced Systems , Transmission Line Trainer Kit , D.C Network Analyzer , Hrc Fuse Link Cylindrical: Rated Current (A) :6A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :10A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :16A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :20A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 50/5A, Burden: 5Va, Accuracy Class: 0.5, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Current Transformer (Ct): Rectangular Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Hrc Fuse Link: 16A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Hrc Fuse Link: 10A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Miniature Circuit-Breaker (Mcb): 6A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 6A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Mccbs: 240V Ac Dy 125U With Thermal Magnetic Release , Mccb: Four Pole, 100 Amp, 25Ka Breaking Capacity , Earth Leakage Circuit Breakers, 25A, 30Ma, 2 Pole, 230V Standard , Earth Leakage Circuit Breakers, 32A, 100Ma, 2 Pole, Standard , Rccb: 32A, Type-Ac, 100Ma , Rccb 4 Pole 16 Amp/30Ma 240 V Residual Current Circuit Breaker , Shunt: 50A, 75 Mv, Class 1.0% For Extension Of Range Of Ammeter , Static Over Current Relay Trainer Kit , Trainer Kit To Study The Speed Control And Reverse Operation Of A.C. Servo Motor , Trainer Kit To Study The Speed Control, Reverse Operation And Position Control Of D.C. Servo Motor: , Trainer Kit To Study Percentage Differential Protection Of Transformer, To Plot Characteristics Of % Biased Differential Relay, Pickup Test For Differential Relay, Transformer Protection For In Zone Trips Faults And Transformer Out Zone Or Non Trip Faults. , Setup To Perform Experiment For Distance Protection Of Transmission Line Lg, Ll, Llg, Lll, Lllg And Auto Reclose Function Of The Relay For Transient Type Faults. , Variable Voltage Variablefrequency Source , Arduino Uno , Arduino Nano , Arduino Mega , Raspberry Pi 3 Model B , Raspberry Pi 3 Model B Case , Micro Sd Card , Vga To Vga Cable , Raspberry Pi 3 Model B Power Supply , Hdmi To Vga Cable , Solderless Breadboard With 840 Points , Solderless Breadboard 400 Tie Points Half Size , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 140Mm X 90Mm (14 Cm X 9 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 80Mm X 55Mm (8 Cm X 5.5 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , Female Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Male Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Dot Matrix Ldc Display With 16 Characters X 2 Lines Green/Blue , Dc12v 3W Submersible Water Pump , Max7219 8X8 Led Dot Matrix Display Module , Hc-05 Bluetooth Module , Led 4-Digit Display Module , Sim900 Gprs Transfer Board Micro Sim Gsm Core Ttl Port Module For Arduino , 5Mm/12Mm, Photosensitive Ldr Light Sensor Module , Neo6mv2 Gps Module With Flight Controller , 650Nm 6Mm 5V Dc 5Mw Mini Laser Dot Diode Module , Universal 16 Key Matrix Module Membrane Switch Keypad 4X4 , 4X4 Matrix 16-Key Keyboard / Keypad Telephone Style , 2-Axis Joystick Module With Push Button Function , 3.3 To 5V Active Buzzer Alarm Module Sensor , L293d Motor Driver Module , Isd1820 Voice Recording Module With On Board Mic And Speaker , Isd1760 Voice Recording And Playback Module With On Board Mic And Speaker , Dc Plastic Gear Motor With Wheel: 12V, 150 Rpm, Side Shaft Bo (Battery Operation) Motor , Esp8266 Ch340 Nodemcu Wi-Fi Module , Wemos Esp8266 D1 R2 V2.1.0 Wifi Development Board , Coin Vibration Motor; Operating Voltage: 1.5-3 V , Atmega16: 8 Bit Microcontroller Individual Ic (Dip); Voltage Range: 2.7V To 5.5V;Operational Range: -40°C To +80°C , Mpr121 Breakout V12 Capacitive Touch Sensor Controller Module I2c Keyboard , Usb Cables A To B , Usb Cables Mini , Piezoelectric Sensor , Alligator Connectors , Hook-Up Wires , Hook-Up Wires , Rgb Leds , Leds (Red) , Leds (Green) , Leds (Blue) , Leds (Yellow) , Leds (White) , Timer Ic - Lm 555 , Ir Infrared Obstacle Avoidance Sensor Module For Arduino Smart Car Robot 3-Wire, Ir Module, Ir Sensor Module - Ml019 , Triple Axis Compass Magnetometer Sensor Module , Temperature And Humidity Sensor Module , Infrared Ir Sensor Receiver Module For Arduino , Arduino Ultrasonic Sensor , Tripple Axis Accelerometer Board , Pir Motion Sensor Detector Module Hc-Sr501 , Pulsesensor Heart Rate Beat Pulse Sensor Module Amplifier For Arduino Raspberry Pi Open Source With Cable Electronic Diy Tool , 2 Channel Dc 5V Relay Module,Optocoupler Low Level Trigger Expansion Board For Arduino Uno R3 Mega 2560 1280 Dsp Arm Pic Avr Stm32 Raspberry Pi , Sound Sensor Big Microphone Sensor High Sensitivity Sound Detection Module , Super Debug Soil Moisture Sensor Module Soil Hydrometer Humidity Detector For Arduino , Super Debug Ttp223 Based Capacitive Touch Sensor Module For Arduino , Metal Touch Sensor Module For Arduino , Rain Sensitive Sensor Module, Rain Drop Detection Sensor Module/Raindrops Humidity Sensor For Arduino , Flex Sensor 2.2? Bend Sensor For Hand Gesture Recognition , Dht11 - Temprature And Humidity Sensor Module , Lm35d Analog Temperature Sensor Module , Colour Recognition Sensor , Water Flow Sensor , Sound Detection Sensor Module , Analog Sound Sensor Microphone Module For Arduino , Power Bank , Rfid 13.56Mhz Reader Writer Module , Rf Transmitter Receiver Module 315Mhz Wireless Link Kit For Arduino , Male To Male Jumper Wires (20Cm) , Male To Female Jumper Wires (20Cm) , Female To Female Jumper Wires (20Cm) , Ka7805 Linear Voltage Regulator , Push Button Switches , Toggle Switch , 2A Digital Mq-2 Smoke Detection Sensor , Mq-135 Air Quality Sensor Hazardous Gas Detection Module For Arduino
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
17.
Housing Urban and Rular Development #10427022 Price Bid
Construction Of Sump Well Pump Room And Sitc Of Rotary Lobe Pump Sets Along With Related Eandm Equipments At Rahim Khan Road Nizamuddin East New Delhi Under Ser-1 Civil And Electrical Work-SH-I Pump Set WorkSupplying, installation, testing and commissioning of Positive displacement Rotary Lobe Pump for draining/dewatering of storm water/sewer water compatiblefor VFD (variable frequency drive) having minimum discharge 500 m3 /hr at 68Hz and 170 m3/hr at 25 Hz for 10 mtr. head and 5 mtr. suction Lift capacity complete withGeared Motorwith minimum power 45 kW/60 HP, 4 Pole suitable for operation on 415 Volt 50 Hzas per additional specification etc. as required. 2 Supplying, fabrication & installation of45KW VFD AUTO CONTROL PANEL made out of CRCA sheet steel of thickness 2mm for load bearing members, 1.6mm for non load bearing section with necessary stiffeners as required. 3 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required: 4 250 m.m dia 5 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required: 6 250 m.m dia 7 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 8 40 mm dia 9 80 mm dia 10 250 mm dia (wall thickness 6.3 mm) 11 450 mm dia (wall thickness 7.0 mm) 12 Fabrication, Supplying, Installation Testing & commissioning of automatic motorised Mechanical Coarse Bar Screen Suitable for channel dimension:i) Channel width: 1000mmii) Channel Depth: 3500 mmiii) Water Depth: 1500 mmiv) Bar Spacing: 20 mmv) Bar size : 12X6X50 mm vi) Angle: 75 Degreevii) MOC: SS304 Peak Flow/ Screen: 27MLDi/c Supplying, Installation, Testing & commissioning of 1No relay based control panel made out of 2mm thick CRCA sheet for 2Nos. Mechanical Coarse Bar Screen & 1No.Belt Conveyor etc. complete as required. - 13 Supplying, Installation, Testing & commissioning of Differential Level Sensorcomprises of Two Ultrasonic Level Sensors and One Differential Transmitter for Mechanical coarse bar screenetc. complete as required. 14 Supplying, Installation Testing & commissioning ofBelt Conveyor of size 600 mm width and2000mm Length i/c accessories for screen etc. complete as required. 15 Supplying, Installation Testing & commissioning of Gate Assy FG A101 Cast Iron Side Wall Embedded Oen Channel Gate (101) Size: 1000(W) X 1000 (H) mm Suitable for 1.75 m Seating water head (From invert Level) , Flush Bottom Closure Arrangement , Manually operated, Close Top Frame Gate etc. complete as required. 16 Supplying, Installation Testing & commissioning of Ultrasonic Level Transmitter with 4 ANSI PP Flange etc. complete as required. 17 Supplying, Installation Testing & commissioning of Local Control Stations for Pump Motors having following accessories i/c making connections etc. complete as required:a)DP MCB, 10kA, C-Curve for Control, 6A;: 1 No.b)Ampere meter, SIF-96, CI-1, Aux Supply 230V AC; 4-20mA I/P;1 No.c)Indicating Light-RED for ON;1 No.d)Indicating Light-AMBER for TRIP;1 No.e)Push Button with 1 NO contact - GREEN for VFD START;1 No.f)Push Button with 1 NC contact - RED for VFD STOP;1 No.g)Push Button with 1 NC contact - Mushroom head RED;1 No.h)Thermistor Relay 252 PMTG;1 No.i)Control Terminals, 2.5 sqmm; 6A;22 Nos. 18 SH-II Diesel Generator SetSupply, installation, testing and commissioning of Silent Type, CPCB IV + emission compliants Diesel Generating set having Prime Power Rating of 200 KVA, at 1500 RPM, 0.8 lagging power factor at 415V suitable for 50 Hz, 3 Phase system & for 0.85 Load Factor with all necessary equipments and accessories and consisting of followings :(a)Diesel EngineDiesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 degree C, 50 % RH & at 1000 meterMSL and conforming to BS 5514, BS 649, IS 10000(amended upto date), capable of taking 10 % overloading for 1 hourafter12hourofcontinuousoperation.Theenginewillbefittedcompletewithall accessories as per specifications .(b)Enginemountedinstrumentpanelfittedwithandhavingdigitaldisplayforthe following :-(i) Start stop switch with Key (ii) Water temperature indication (iii) lubrication oiltemperatureindication(iv)lubricationoilpressureindication(v) Batterycharging indication (vi) RPM indication (vii) Over speed indication (viii)Low lube oil trip indication(ix) Engine hour indication. 19 (c)AlternatorSynchronous alternator rated at 200 KVA, 415V, at 1500 RPM, 3 Phase, 50Hz, AC Supply with 0.8 lagging power factor at 40 Degree C, 50% Relative Humidity & at 1000m above MSL. The alternator shallbehavingSPDPenclosure,brushless,continuousduty,self-excitedandself-regulatedthrough AVR, confirming to IS: 4722 /BS : 2613suitable for tropical conditions and withF/H insulation.(d) Base Frame &foundation: Both the Engine & alternator shall be mounted on suitable baseframemadeofMSchannelwithnecessaryreinforcementwhichshallbeinstalledon suitablecementconcretefoundationandvibrationisolationarrangementasper recommendations of manufacturer.(e) Fuel Tank : Daily service fuel tank ofminimum 385 Ltr capacity fabricated out of 3mm thick MS sheet complete with all standard accessories and fuel piping between fuel tank & diesel engine with MS class C Pipe of suitable dia complete with valves, level indicators, and accessories as required as per specification.(f) Exhaust System : Dry exhaust manifold withsuitable exhaust residential gradesilencer . 20 (g) Starting system : 24V DC starting system comprising of starter motors, voltage regulator and arrangementforinitialexcitation,completewith suitableno. of batteries(25Plates,180 AmpsHour Capacitylead acid type) as required as per specification.(h) Acoustic Enclosure : Acoustic and weather proof enclosure with arrangement for fresh airintakeforcoolingoftheengineandalternator,extractiondischargeofhotairinto atmosphere as per specifications. 21 AMF Panel(i) Fabricating,Installation, Testing & Commissioningofautomaticmainsfailurecontrolincludingautobypasspanel,suitable for 200 KVAsilenttypeDGsetcompletewithrelays,timers,setofCTs,formeteringand protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH& Provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to Diesel Engine and elsewhere, if required, all complete and interlocking including the following :-(a) 3 nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release.(b)Auto / manual /test/off selector switch.(c) 2 nos. over voltage relay, 2 nos. reverse power relay and 2 nos. under voltage relay.(d)1 no. Auto mains failure relay(e) 3 sets of current transformer15P 10 accuracy for protection andclass 1, 15VA class-Ifor metering and. AMF Relay.(f) Energy analyzer unit to indicate current, voltage, frequency power factor and KWH.(g) Indicating lamps for load on mains and load on set.(h) Fuse for instruments.(i) Battery charger, complete with all accessoriesand Ammeter,voltmeter etc. 22 (j) Supply failure& restoration timer(k) Main supply failure monitor(l) Control unit with three impulse automatic engine start/stop and failure to start lock out.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator.(o)Aux. contactor 2NO+2NC(p) Audio/Video annunciation for :(i) High water temperature.(ii) Low lubricating oil pressure.(iii) Engine over speed(iv) Engine fails to start.(v) Full load/ Maximum load warning. 23 Main LT PanelSupplying, installation, testing & commissioning of LT panel of minimum front area 3.15 sq. mtr. and depth not less than 45 cm, made out ofCRCA Sheet Steel 2mm for section with necessary stiffeners as required. Free standing, self supported, floor mounting, single front, indoorinstallation, non draw out and compartmented. ISMC-100 fabricated channel frame with undrilled holes.Bottom with undrilled detachable 3mm gland plate as per order .Welding will be carried out with no external deposition of welded material in particular places and there will not be any gap between the welded materials.Siemens Grey RAL 7032CRCA Structures shall be pre-treated in seven tank chemical process, heated in baking oven.Minimum 60 micron of approved shade (RAL-7032).230V AC for Main LT Panel and Other Panels415+/- 5% , 50Hz+/-5%, 3 Phase 4 Wire 50KA – 1 Sec TPN Aluminum Electrolytic Grade ( E-91E) busbar shall be provided as per suitable sze, duly supported on SMC/DMC, busbar supports & insulated with color coded heat shrinkable sleeve. Power wiring will be through Vertical Bus -Bar and 1.1 KV grade PVC multistrand copper flexible cable . All control wiring will be done by 1.5 sq mm copper flexible PVC multi strand wire. CT wiring shall be carried out with 2.5 sq mm copper flexible PVC multistrand wire.1. All R,Y,B,N phases will be Red, Yellow , Blue & Black 2.All control wiring will be Grey colour. Earthing shall 24 be be with Green color wire.3.C.T. - Wiring through Red, Yellow, Blue, Black coloured wiring with shorting link type terminals.EPDM gasket provided at all joints, doors & covers to make panels dust & vermin proof (IP-52)Section-I(a) INCOMER :-1No. 4nos. 400 A 36KA, 4 Pole with thermo-magnetic release double break MCCBwith O/L,S/C & E/Fprotection with Aux . And trip contact and shunt release. Ics=100%Icu i/c extended rotary handle and spreaders and all required accessaries Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch & back up HRC fuses/MCBs … complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set(b) 400 AOnload Change over SwitchIcs=100%Icu i/c extended rotary handle and spreaders and all required accessories- 1setIndicating lamp On, OFF, TRIP /R/Y/B/Ready to close complete 1set(c) OUT GOINGS:- 4Nos. 100A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etc complete as reqd. 25 Digital 96 mm square flush pattern type Voltmeter (0-500 V) with selector switch etc complete 1 set.Digital 96 mm square flush pattern type Ammeter (0-400 Amp)with selector switch and one set of 3 Nos. CTs of ratio 400/5A class 1 accuracy and 10 VA burden - 1 set.Indicating lamp On, OFF, TRIP /R/Y/B/Ready to close…complete 1set3 Nos. 63A FP MCCB ( 25kA) with thermo-magnetic release i/cextended rotary handle & spreaders. Ics=100%Icu etcwith indicating Lamps complete as reqd. 26 SH-III EI Work Supplying & Laying of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following size on cable tray as required. 27 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable (clamped with 40x3mm MS flat clamp) 28 3 X 50 sq mm (clamped with 25x3mm MS flat clamp) 29 Supplying, Laying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cableof 1.1 KV grade of following sizes on wall surface etc. as required. 30 4X25 Sq. mm. (clamped with 1mm thick saddle) 31 Supplying & Laying and fixing of one number PVC sheathed XLPE insulated power cable of 1.1 KV grade of following sizedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 32 3.5 x 240 Sq.mm XLPE Al Conductor Armoured Cable 33 Supplying and Laying of XLPE insulated and PVC sheathed Copper conductor armoured Power Cable of 1.1 KV grade of following size on cable tray as required. 34 4x4 Sq.mm. 35 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 36 3½ X 240 sq. mm (62mm) 37 3 X 50 sq. mm (32mm) 38 4 X 25 sq. mm (28mm) 39 Supplying and drawing following size of PVC insulated copper conductor multicore cable of following size on cable tray as required. 40 10 core 1.5 sq.mm 41 24 core 0.5 sq.mm 42 4 core 0.5 sq.mm 43 2 core 1.5 sq.mm 44 6 core 0.5 sq.mm 45 3 core 0.75 sq.mm 46 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 450 mm width X 50 mm depth X 2.0 mm thickness 49 EarthingEarthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 50 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 51 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithbrassnut,bolt,spring,washerexcavationandre-fillingetc.as required. 52 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 53 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode includingconnectionwithG.I.nut,bolt,spring,washerexcavationandre-fillingetc.as required. 54 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. asrequired. 55 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 56 Group C 57 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 58 3 x 4 sq. mm 59 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 60 25 mm 61 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 62 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 63 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 64 4 way (4 + 12), Double door 65 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 66 Single pole 67 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 68 63 amps 69 Supplying, Installation, testing & commissioning of weather proof LED Corrosion resistant battentype LED fitting of following wattagewith IP65 body made out of polycarbonate housing & opal diffuser with better thermal managementCCT-5700°KLumen Efficacy ≥110 Lm/W Power Factor≥ 0.95, CRI≥70, with constant current driver etc. complete as reqd. 70 36 Watt (4 feet ) 71 SITC of 450 mm heavy duty Exhaust Fan 1400 RPMsingle phase 240 Volt 50 Hz in the existing opening, complete with heavy duty louver/ shutter i/c making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning & earthing etc. as required 72 SITC of 600mmwall mounted fan having 3 nos. of blades, 1440RPM etc complete as reqd. 73 SH-IV AMCAMC for pump sets, Motor control panel and other accessories starting after satisfactory completion defect liability period from date of completion and commissioning of the pumping system.Annual Comprehensive maintenance for all 3 Nos. Pump sets, Motor, VFD Auto control panel, Mechanical Course Bar Screen, Differential Level sensor, Ultra Sonic Level Transmeter, Belt conveyor, Gate assembly including all accessories and consumables etc. all complete and as per site requirement as per Engineer-in-charge. 74 For 1st Year (Free Maintenance period) 75 For 2nd Year 76 For 3rd Year 77 Comprehensive maintenance of 200 KVA Silent type DG Set with AMF Panel. Annual Comprehensive maintenance of 200 KVA DG set and its accessories with AMF Panel i/c repairing, servicing, cleaning, checking and Descaling with replacment of following consumable parts i.e oil filter, fuel filter, air filters, coolant, lube oil, coolant filter, battery water, V Belts and batteries etc. complete and as per site requirement as per Engineer-in-charge. 78 For 1st Year (Free Maintenance period) 79 For 2nd Year 80 For 3rd Year 81 Civil WorkDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 82 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 83 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. 84 All kind of soil. 85 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 86 Providing and laying in position ready mixed or site batched design mix cement concrete for plai plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads: but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 87 Concrete of M10 grade with minimum cement content of 220 kg /cum 88 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 89 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 90 Suspended floors, roofs, landings, balconies and access platform 91 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 92 Edges of slabs and breaks in floors and wallsAbove 20 cm wide 93 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana / Ordinary Portland /Portland Slagcement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade withminimum cement content of 330 kg /cum 94 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 95 Thermo-Mechanically Treated bars of grade Fe-500D or more. 96 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 97 Cement mortar 1:4 (1 cement : 4 coarse sand) 98 12mm cement plaster of mix 1:4 (1cement:4 fine sand). 99 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 100 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 101 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 102 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 103 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m :Ordinary roack 104 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 105 Providing and fixing soil, waste and vent pipes : 100 mm dia. : 106 Sand cast iron S&S pipe as per IS: 1729. 107 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 108 Circular shape 450 mm dia 109 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 110 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 111 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 112 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 113 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm : 114 Sand cast iron S&S as per IS - 1729 115 Providing and fixing plain bend of required degree : 100 mm 116 Sand cast iron S&S as per IS - 1729 117 Providing and fixing single equal plain junction of required degree: 100x100x100mm, 118 Sand cast iron S&S as per IS-1729. 119 Providing and fixing terminal guard: 100mm : 120 Sand cast iron S&S as per IS:1729. 121 Providing and fixing collar:100mm : 122 Sand cast iron S&S as per IS:1729. 123 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 124 100mm : 125 Providing and fixing trap of self cleanising design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet and 100mm outlet : 126 Sand cast iron S&S as per IS:3989. 127 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes. Weighing not less than 60 gms. 128 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 129 25mm dia nominal bore. 130 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tees including cutting andthreading the pipe etc. complete : 131 25 to 40mm nominal bore. 132 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc : Externalwork : 133 32mm dia nominal bore. 134 Providing and fixing C.P. brass bib cock of approved quality confirming to IS :8931 : 135 15mm nominal bore. 136 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS:8931 : 137 15mm nominal bore. 138 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 139 25mm nominal bore. 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure with plastic floats : 141 25mm nominal bore. 142 Providing and fixing brass ferrule C.I. mouth cover including boring and taping the main : 143 25mm nominal bore. 144 Providing and fixing unplasticised PVC connection pipe with brass unions : 45cm length : 145 15mm nominal bore. 146 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 147 Providing and fixing PTMT grating of approved quality and colour : Circular type : 148 100mm nominal dia. 149 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying a priming coat of approved steel primer : E.R.W. tubes. 150 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 151 Size of tile600x600mm. 152 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.Single socketed pipes : 153 110mm diameter. 154 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Bend 87. 5° : 155 110mm bend. 156 Providing and fixing on wall face unplasticised –PVC moulded fittings / accessories for unplsticised rigid PVC rain water pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion : Shoe (Plain) : 157 110mm Shoe. 158 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 159 Two or more coats on new work. 160 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : 161 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 162 Providing and laying in position ready mixedor site batched design mix cement concrete for plain cement concrete work;usingcoarse aggregateandfine aggregate derived from natural sources and usingrecycled concrete aggregate (RCA)as coarse aggregate and fine aggregate within thepermissible utilization,PortlandPozzolana / Ordinary Portland/Portland Slag cement,admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concreteto improvedurability andworkabilitywithout impairing strength;including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering and finishingas per direction of the engineer-in-charge; for thefollowing grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level 163 Concrete of M25 grade with minimum cement content of 300 kg /cum.(Note: The permissible utilization of Recycled Concrete Aggregate (RCA) as coarse aggregate and fine aggregate is 25% each). 164 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 165 With 20x20 mm square bar 166 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 : 167 450 mm dia Ductile Iron Class K-9 pipes. *For use of bigger dia. pipes other than 450mm, net difference in basic rate as per applicable DSR shall be reimbursed to the contractor. 168 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :(i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 169 (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.Using rough kota stone. 170 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 171 Using rough Kota stone 172 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 173 Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : 174 Red sand stone slab40 to 50 mm thick 175 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 176 40 to 50 mm thick 177 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings, glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 178 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 179 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 180 Made of G.I. wire of dia 4 mm 181 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 182 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) 183 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 Modified estimated cost after using correction factor on DSR-2023 on account of GST @0.973 vide O.M. dated 08.08.2024.(i.e. 9720555 *0.973 = 9458100 185 Carrying out structural analysis and design of all civil work, Design of all E&M works, foundation and superstructure of work such as pump-room, UGT and Delivery line upto Barapullah Drainage etc. all complete and submission of input data, check print structural drawing, 6 Nos. prints with soft copy of analysis and drawings as per direction of Engineer-in-Charge by approved structural consultant agency. The profile of structural consultant shall be got approved from NIT approving authority. The structural design shall be comprehensive to enable easy servicing of pumps and other heavy equipment’s etc. possible. The Hydrological data shall be provided to the consultant for drainage design.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
18.
Drinking Water Supply and Sanitation #10406233 Price Bid
Tender For Nagar Panchayat Suchittaganj (Khirauni) Water Supply And House Connection Scheme District-Ayodhya - DISTRIBUTION SYSTEM 2 Supply of following sizes and type of pipes with all jointing materials such as socket, rubber gasket as per IS 4984/1995 and IS-8329/2000 or their latest amendment including F.O.R. destinationand all taxes and insurance etc. with loading, unloading and stacking all complete. 3 HDPE PipePN-6 PE-100 4 90 mm dia 5 110 mm dia 6 140 mm dia 7 160 mm dia 8 DI Pipe Class K-7 9 200 mm dia 10 250 mm dia 11 300 mm dia 12 Carting of following size & type of pipes and specials to site of work and lowering them into the trenches and laying true to alignmentand gradient and jointing etc. complete including testing of pipe lines and cutting of pipes. 13 HDPE PipePN-6 PE-100 14 90 mm dia 15 110 mm dia 16 140 mm dia 17 160 mm dia 18 DI Pipe Class K-7 19 200 mm dia 20 250 mm dia 21 300 mm dia 22 Excavation for pipeline work in ordinary Soil (loam, clay orsand) with lift up to 1.5 M and lead up to 50 M including filling back the excavated earth into the trenches with watering, ramming and disposal of surplus earth with in 50 M lead. 23 Supply of following sizes D.I.D./F Sluice valve including F.O.R. destination and taxes and insurance etc. complete as per relevant IS. 24 D. I. D/F Sluice Valve 25 80 mm dia 26 100 mm dia 27 125 mm dia 28 150 mm dia 29 200 mm dia 30 Scour valve 80 mm dia 31 Fire Hydrant 80 mm dia 32 C.I. Single ball type Air Valve 25 mm dia 33 Carting of following sizes D.I.D./ F Sluice Valve and specials from departmental store to site of work and lowering them into the trenches, fixing in position and jointingthem with pipelines and testing etc. complete including supply of jointing materials. 34 D. I. D/F Sluice Valve 35 80 mm dia 36 100 mm dia 37 125 mm dia 38 150 mm dia 39 200 mm dia 40 Scour Valve 80 mm dia 41 Fire Hydrant 80 mm dia 42 C.I. Single ball type Air Valve 25 mm dia 43 Supply of all materials and construct following chambers as per type design with supply of all labour, T&P etc. complete. 44 Masonary Type 45 Fire Hydrant Chamber 46 Air Valve Chamber 47 Surface Box Type 48 Dismentling of following type of road and stacking of useful materials including supply of all materials, labour, T&P etc. complete. 49 BOE Road 50 C.C. Road 51 Bitumen Road 52 Interlocking 53 Reinstatement of following type road As per PWD specification 54 BOE Road (with40 % New Bricks and 60 % old Undamaged serviceable bricks) 55 C.C. Road (with 150 mm PCC base of 1:4:8 cement: coarse sand: 40 mm Stone Aggregate and 100 mm Cement Concrete course of 1:1.5:3 cement: coarse sand: 20 mm Stone Aggregate) 56 Bitumen Road PWD1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 57 Interlocking Tile Road (40 % New interlocking tile 80 mm thick M 35 Grade and 60 % old serviceable tiles , Plain cement concrete in 75 mm thickness 1:6:12 cement :coarse sand: 40 mm stone aggregate in base) 58 Provision for following types of Culvert crossing along the alignment of pipe line complete as per instructions of Engineer ‐in ‐charge. (casing of pipe is done by concreting) 59 Nala/Culvert Crossing ( width ‐3.5 m) 60 Making house connection should be done atleast 2 m inside the boundary wall with provision of tap from distribution line to outer wall of house with supply of 1 m above GL G.I. pipe ( 15 mm ) ( above ground ) & average 5 mtr. MDPE Pipe ( 20 mm) ( below ground) including specials saddle Tapetc. of suitable size T&P etc. including excavation laying and jointing for proper completion of work as per instructions of Engineer as per Dwg 12 (including dismantling and reinstatement of road) 61 In C.C. roads 62 For 90 mm to 110 mm dia 63 For 125 mm to 160 mm dia 64 For 180 mm to 250 mm dia 65 For 250 mm to 300 mm dia 66 In bituminous roads 67 For 90 mm to 110 mm dia 68 For 125 mm to 160 mm dia 69 For 180 mm to 250 mm dia 70 For 250 mm to 300 mm dia 71 In BOE roads 72 For 90 mm to 110 mm dia 73 For 125 mm to 160 mm dia 74 For 180 mm to 250 mm dia 75 For 250 mm to 300 mm dia 76 In C.C. Interlocking Tiles roads 77 For 90 mm to 110 mm dia 78 For 125 mm to 160 mm dia 79 For 180 mm to 250 mm dia 80 For 250 mm to 300 mm dia 81 In Kachcha roads 82 For 90 mm to 110 mm dia 83 For 125 mm to 160 mm dia 84 For 180 mm to 250 mm dia 85 For 250 mm to 300 mm dia 86 LAYING OF RISING MAIN 87 Supply of D.I. pipes (K-9)offollowing size/wall thickness with I.S. 8329/2000 or its latest amendments with jointing materials including FOR destination and all taxes and insurance and including all specials of rising mainetc. complete. 88 150mm dia DI K-9 89 200mm dia DI K-9 90 Excavation of earth for pipe line trenches in ordinary soil (loam, clay or sand) with lift upto 1.5 and lead upto 50M filling back the earth into trenches including watering, ramming and disposal of surplus material with in 50M lead etc. complete. 91 Carting of following sizes D.I. pipes class K-7/9 and specials to the site of work loweering them in to trench and laying true to alignment including testing of pipeline but excluding cost of trenching and cutting of pipes etc. for making of length but including making joints. 92 DI Pipe Class K-9 93 150mm dia DI K-9 94 200mm dia DI K-9 95 Dismentling of following type of road and stacking of useful materials including supply of all materials, labour, T&P etc. complete. 96 BOE Road 97 C.C. Road 98 Bitumen Road 99 Reinstatement of following type road As per PWD specification 100 BOE Road (with40 % New Bricks and 60 % old Undamaged serviceable bricks) 101 C.C. Road (with 150 mm PCC base of 1:4:8 cement: coarse sand: 40 mm Stone Aggregate and 100 mm Cement Concrete course of 1:1.5:3 cement: coarse sand: 20 mm Stone Aggregate) 102 Bitumen Road PWD1.granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.2.granular sub-base With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 125 mm layer thickness.3. Providing, laying, Spreading & Compacting graded stone aggregateto wet mix macadam. (150 mm thickness)4. Providing & applying PrimeCoat with medium bitumen VG 10 on prepared surfacespreading primer at the rate of 0.75 Kg./Sqm.5.P/L of 40mm thick BC with 100-120 TPH batch type HMP Producing and Avg. Output of 75 TPH using crushed aggt. Of specified grading premixed with bituminous binder VG 30 @ 5.5 %6.Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size7. Providing all necessary barricating and road painting work. 103 Supply of all material, labour, T&P and construct RCC thrust blocks at the bends etc. complete. 104 From 150 mm 105 Supply of following sizes D.I.D./F sluice value as per I.S. 14846:2000 working presure 10 kg/cm^2F.O.R. destination and all texes and insurance 106 D. I. D/F Sluice Valve 107 150 mm dia 108 200 mm dia 109 Carting of following sizes D.I.D./F Sluice Valve and specials to site of work and lowering them into the trenches, fixing in position and jointingthem with pipelines and testing etc. complete including supply of jointing materials. 110 D. I. D/F Sluice Valve 111 150 mm dia 112 200 mm dia 113 Supply of all material labour, T&P etc. Required and construct of Sluice Valve Chamber Masonry Type as per type design. 114 Provide all materials labour T&P etc. complete and construct Pump house size (3.6x3.0x3.0)m Chlorinating room size (2.60x1.80x3.0)m as per departmental type design and drawing (drawing No‐D‐2) and as per the specifications for civil work given in the bid document including supply of all material labour and T&P etc complete as per instructions of Engineer ‐in-charge. 115 Construction of O.H.T. 116 Supply of all materials labour T&P etc. complete and construction of R.C.C. (M-30 Grade) Over Head Tank of following capacity and staging above ground level with all work complete, including cost of soil testing. All the components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682, I.S.3370 part (I) & (II) and I.S.456.Minimum depth of foundation below original ground level will be 2.5M. Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and as per I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind).The cost of OHT should be quoted assuming the bearing capacity of soil as 8 M.T.per sqm. including 1M wide RCC staircase from ground level to balcony. M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars(specification of M.S. should be as per IS 800-2007)with hand rails of 20mm medium class G.I. pipes on both sides in three rows from 117 balcony to top dome resting on an RCC platform (75cmx75cm and 10cm thick) projecting from top ring beam and one aluminum ladder inside the tank body (from manhole in top dome to bottom as per design and specification approved by Engineer in charge. 1 m wide R.C.C. M-30 balcony around the tank at the junction point of vertical wall and conical wall. Proper railing of 20mm diamedium class G.I. pipe (in 3 rows) on both sides of stair case, around the balcony, at each landing and from landing with top ring beam upto manhole on the top dome and at the periphery of top dome. The G.I. Pipes will be supported on M.S. posts made ofor RCC post,spaced at intervals not more than 1.5m.Proper ventilator at top dome in circular shape of 1.2 m dia. along with an R.C.C. cover of minimum 1.50m dia and with mosquito net of standard quality along withexpanded metaled jali between top dome and RCC cover. Water level indicator fabricated with good quality minimum45mm x 45mm section, of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good paint with brass wire rope, pulley, copper ball float, pointer etc.Lightening conductor should be as per I.S.S.2309 or its latest amendments of latest electricity rules. C.I. manhole cover of min 60x60cm size with locking arrangement, Supply, fixing & jointing of D.I.D./F Pipes (for inlet, outlet, washout and overflow pipes) and specials, duck foot bend and fixing of the sluicevalve at outlet and wash out pipe with all specials; construction of sluice valve chamber, floor and apron with semi circular drain around the apron with 25mm PCC 1:2:4 over 75 mm PCC 1:4:8, Apex painting on outer surface of OHT, painting on MS ladder, railing, vertical pipe etc. as per approved make; excavation in all type of soil and all other works required for proper and complete construction of OHT, testing of tank for water tightness as per the satisfaction of Engineer In-Charge. 118 Zone 1, 700Kl Capacity / 20M staging 119 Zone 2, 800Kl Capacity / 22M staging 120 Zone 3, 900Kl Capacity / 22M staging 121 CONSTRUCTION OF NEW BOUNDARY WALL, APPROACH ROAD AND GATE 122 Construction of boundary wall around pumphouse and O.H.T as per type design including supply of all Materials, Labour, Tools and Plants etc. complete. 123 Supply & fixing of 3.60 M & 1.20 M wide MS Gate including fabrication and supply of steel and construction of boundary pillars all complete. 124 Supply Earth filling in plingth including filling, dressing and ramming earth or sand or bajari or ballast or kankar or shingle. 125 Construction of interlocking approach road with both side brick Eadge and earth filling including supply of all materials, labour, tools and plants etc. complete. 126 Construction of MCS, centralized control room including supply of all materials, labour, T & P complete. 127 Construction of chlorine dosing room including supply of all materials, labour, T & P etc. complete. 128 E / M works 129 For Zone - 01 (New TW -02 Nos.) 900 LPM 130 Transportation of Rig Machine & its T&P/equipments to the site of work including loading & unloading, baricating, erection & dismantling etc. 131 Transportation of Air Compressor and its T&P including loading & unloading, erection & dismantling etc. 132 Transportation of OP Unit and its T&P including loading & unloading. erection &dismantling etc. 133 DC Drilling upto 165M 134 Drilling of 600 mm. dia bore from G.L. to 60 m BGL. 135 Drilling of 500 mm. dia bore from 60 mto 100 m BGL. 136 Drilling of 500 mm.dia bore from 100 M bglto 165 m BGL. 137 LOWERING OFTUBE WELLASSEMBLYAND SHROUDINGOF TW BY GRAVEL 138 Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following : Lowering of 300mm X 150mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 165 m BGL. 139 300mm dia MS ERW pipe from G.L. to 54 mBGL 140 150 mm.dia M.S ERWplain/ slotted pipe from 54 m BGL to 100 m BGL 141 150 mm.dia M.S ERWplain/ slotted pipe from 100 m BGL to 150 m BGL 142 TUBE WELL ASSEMBLY : Supply including loading & unloading of TW assembly of MSERW pipe. 143 M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) well cap, bail pliug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. 144 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick ,required M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc complete in all respect . 145 150mm dia MSERW 7.1mm thick plain /slotted pipe including with required M.S ring 100X12mmthick , 1 noM.S. bail plug , required center guide etc comp in all respect. 146 PEA- GRAVEL 147 Supply of 1.6 mm to 4.8 mm size pea gravel duly screened and washed as per IS 4097 148 DEVELOPMNET OF TUBE WELL 149 Development of Tube well by 250 PSI Compressoras per IS-11189 including Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 150 DEVELOPMENT OF TUBE WELL BY 3 Cusec O.P. UNIT AS PER IS 2800 :- 151 Development of Tube well by 3 Cusec O.P. Unit including Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 152 TEST : 153 Chemical and Bacteriological test of water sample from departmental approved lab 154 Electrical Logging of the Bore 155 Barricading Arrangement at Site during construction of TW & Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development( Compressor & O.P.Unit) of work. 156 Pumping Plant including Servo Stablizer and Chlorinating Plant 900 LPM/55 M Head - 02 Nos( 02 Nos. for New TW) 157 SITC of900 LPM, 55 m head or suitable head as per site condition and direction of engineer in charge 2900rpm, 20 HP submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) with 150 mm dia size 24 meter column pipe, 150 mm dia NRV, 150 mm dia CI D/F Bend 90 Degree, 150 mm dia CI A/F Tee, 150 mm dia D/F pipe (1.5 m long 2 nos. and 1 m long 1 no.), earthing, painting, Toolset, Power wiring of pump house internal and external, 2 Tonne chainpully block P-type indef make, and all pumping plant accessories with nut bolts and rubber packing etc. 158 Fully automatic ServoVoltage Stabilizer having(25 KVA or suitable capacity as per actual site requirements and as per direction of Engineer in Charge) fully copper winding 3- phase A.C. Supply 50 Hz.input voltage 200 V output voltage 470 V with T/F oil ,power cable & earthing etc.complete in all respect or as per direction of engineer in charge/ as per site requirement. 159 SCADA compatable chlorinatingSystem 160 CE / UL certified Intelligent smart energy meter 161 Motor OperatedActuator with Sluice Valve (150mm) 162 CE / UL certified Electromagnetic flowmeter of size:150mm 163 Digital Soft starter (15 KW) 164 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (100 Amps) 165 CE / UL certified Hydrostatatic type sub soil water level transmitter 166 CE / UL certified Pressure Transmitter 167 CE / UL certified Surge protector for control panel 168 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 169 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 170 Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse upto meter 171 Fully Automation of TW & OHT through SCADA complete in all respect including mobile based app development and interconnection with MCS and central control room Lucknow with CE&UL Certified PLC/RTU in IP54 including GSM/GPRS based wireless communication with 4G modem for RTU/PLC or as per direction of engineer in charge/ as per site requirement. 172 Automation ofESR Through SCADA For Zone - 1 173 Double Solenoid Flow Control Valve 200 mm dia 174 Double Solenoid Flow Control Valve 250 mm dia 175 CE / UL certified Pressure Transmitter 176 CE / UL certified Electromagnetic flowmeter of size 200 mm dia 177 CE / UL certified Electromagnetic flowmeter of size 250 mm dia 178 Resedual Chlorine Analyser 179 Required Equipments to br install at OHT 180 Motor operated Sluice Valve with Actuator 300 mm dia Size 181 Electromagnetic Flowmeter 300 mm dia Size 182 Ultrasonic Level Sensor 183 For Zone - 02 (New TW -02 Nos.) 900 LPM 184 Transportation of Rig Machine & its T&P/equipments to the site of work including loading & unloading, baricating, erection & dismantling etc. 185 Transportation of Air Compressor and its T&P including loading & unloading, erection & dismantling etc. 186 Transportation of OP Unit and its T&P including loading & unloading. erection & dismantling etc. 187 DC Drilling upto 165M 188 Drilling of 600 mm. dia bore from G.L. to 60 m BGL. 189 Drilling of 500 mm. dia bore from 60 mto 100 m BGL. 190 Drilling of 500 mm.dia bore from 100 M bglto 165 m BGL. 191 LOWERING OFTUBE WELLASSEMBLYAND SHROUDINGOF TW BY GRAVEL 192 Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following : Lowering of 300mm X 150mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 165 m BGL. 193 300mm dia MS ERW pipe from G.L. to 54 mBGL 194 150 mm.dia M.S ERWplain/ slotted pipe from 54 m BGL to 100 m BGL 195 150 mm.dia M.S ERWplain/ slotted pipe from 100 m BGL to 150 m BGL 196 TUBE WELL ASSEMBLY : Supply including loading & unloading of TW assembly of MSERW pipe. 197 M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) well cap, bail pliug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. 198 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick ,required M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc complete in all respect . 199 150mm dia MSERW 7.1mm thick plain /slotted pipe including with required M.S ring 100X12mmthick , 1 noM.S. bail plug , required center guide etc comp in all respect. 200 PEA- GRAVEL 201 Supply of 1.6 mm to 4.8 mm size pea gravel duly screened and washed as per IS 4097 202 DEVELOPMNET OF TUBE WELL 203 Development of Tube well by 250 PSI Compressoras per IS-11189 including Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 204 DEVELOPMENT OF TUBE WELL BY 3 Cusec O.P. UNIT AS PER IS 2800 :- 205 Development of Tube well by 3 Cusec O.P. Unit including Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 206 TEST : 207 Chemical and Bacteriological test of water sample from departmental approved lab 208 Electrical Logging of the Bore 209 Barricading Arrangement at Site during construction of TW & Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development( Compressor & O.P.Unit) of work. 210 Pumping Plant including Servo Stablizer and Chlorinating Plant 900 LPM/55 M Head - 02 Nos( 02 Nos. for New TW) 211 SITC of900 LPM, 55 m head or suitable head as per site condition and direction of engineer in charge 2900rpm, 20 HP submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) with 150 mm dia size 24 meter column pipe, 150 mm dia NRV, 150 mm dia CI D/F Bend 90 Degree, 150 mm dia CI A/F Tee, 150 mm dia D/F pipe (1.5 m long 2 nos. and 1 m long 1 no.), earthing, painting, Toolset, Power wiring of pump house internal and external, 2 Tonne chainpully block P-type indef make, and all pumping plant accessories with nut bolts and rubber packing etc. 212 Fully automatic ServoVoltage Stabilizer having(25 KVA or suitable capacity as per actual site requirements and as per direction of Engineer in Charge) fully copper winding 3- phase A.C. Supply 50 Hz.input voltage 200 V output voltage 470 V with T/F oil ,power cable & earthing etc.complete in all respect or as per direction of engineer in charge/ as per site requirement. 213 SCADA compatable chlorinatingSystem 214 CE / UL certified Intelligent smart energy meter 215 Motor OperatedActuator with Sluice Valve (150mm) 216 CE / UL certified Electromagnetic flowmeter of size:150mm 217 Digital Soft starter (15 KW) 218 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (100 Amps) 219 CE / UL certified Hydrostatatic type sub soil water level transmitter 220 CE / UL certified Pressure Transmitter 221 CE / UL certified Surge protector for control panel 222 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 223 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 224 Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse upto meter 225 Fully Automation of TW & OHT through SCADA complete in all respect including mobile based app development and interconnection with MCS and central control room Lucknow with CE&UL Certified PLC/RTU in IP54 including GSM/GPRS based wireless communication with 4G modem for RTU/PLC or as per direction of engineer in charge/ as per site requirement. 226 Automation ofESR Through SCADA For Zone - 2 227 Double Solenoid Flow Control Valve 200 mm dia 228 Double Solenoid Flow Control Valve 250 mm dia 229 CE / UL certified Pressure Transmitter 230 CE / UL certified Electromagnetic flowmeter of size 200 mm dia 231 CE / UL certified Electromagnetic flowmeter of size 250 mm dia 232 Resedual Chlorine Analyser 233 Required Equipments to br install at OHT 234 Motor operated Sluice Valve with Actuator 300 mm dia Size 235 Electromagnetic Flowmeter 300 mm dia Size 236 Ultrasonic Level Sensor 237 For Zone - 03 (New TW -02 Nos.) 1100 LPM 238 Transportation of Rig Machine & its T&P/equipments to the site of work including loading & unloading, baricating, erection & dismantling etc. 239 Transportation of Air Compressor and its T&P including loading & unloading, erection & dismantling etc. 240 Transportation of OP Unit and its T&P including loading & unloading. erection & dismantling etc. 241 DC Drilling upto 165M 242 Drilling of 600 mm. dia bore from G.L. to 60 m BGL. 243 Drilling of 500 mm. dia bore from 60 mto 100 m BGL. 244 Drilling of 500 mm.dia bore from 100 M bglto 165 m BGL. 245 LOWERING OFTUBE WELLASSEMBLYAND SHROUDINGOF TW BY GRAVEL 246 Welding and lowering of TW Assembly (including electrodes welding set and generator etc. required for completion of work) as per following : Lowering of 300mm X 200mm dia (tube well assembly in bore hole and shrouding of pea gravel between annular space of bore hole and T.W. assembly from G.L. to 165 m BGL. 247 300mm dia MS ERW pipe from G.L. to 54 mBGL 248 200 mm.dia M.S ERWplain/ slotted pipe from 54 m BGL to 100 m BGL 249 200 mm.dia M.S ERWplain/ slotted pipe from 100 m BGL to 150 m BGL 250 TUBE WELL ASSEMBLY : Supply including loading & unloading of TW assembly of MSERW pipe. 251 M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) well cap, bail pliug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. 252 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick ,required M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc complete in all respect . 253 150mm dia MSERW 7.1mm thick plain /slotted pipe including with required M.S ring 100X12mmthick , 1 noM.S. bail plug , required center guide etc comp in all respect. 254 PEA- GRAVEL 255 Supply of 1.6 mm to 4.8 mm size pea gravel duly screened and washed as per IS 4097 256 DEVELOPMNET OF TUBE WELL 257 Development of Tube well by 250 PSI Compressoras per IS-11189 including Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 258 DEVELOPMENT OF TUBE WELL BY 3 Cusec O.P. UNIT AS PER IS 2800 :- 259 Development of Tube well by 3 Cusec O.P. Unit including Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development of work. 260 TEST : 261 Chemical and Bacteriological test of water sample from departmental approved lab 262 Electrical Logging of the Bore 263 Barricading Arrangement at Site during construction of TW & Cutting of T.W. cover by gas cutter, re-welding of T.W. cover by Electric welding after complete development( Compressor & O.P.Unit) of work. 264 Pumping Plant including Servo Stablizer and Chlorinating Plant 1100 LPM/55 M Head - 02 Nos( 02 Nos. for New TW) 265 SITC of1100 LPM, 55 m head or suitable head as per site condition and direction of engineer in charge 2900rpm, 25 HP submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) with 150 mm dia size 24 meter column pipe, 150 mm dia NRV, 150 mm dia CI D/F Bend 90 Degree, 150 mm dia CI A/F Tee, 150 mm dia D/F pipe (1.5 m long 2 nos. and 1 m long 1 no.), earthing, painting, Toolset, Power wiring of pump house internal and external, 2 Tonne chainpully block P-type indef make, and all pumping plant accessories with nut bolts and rubber packing etc. 266 Fully automatic ServoVoltage Stabilizer having(25 KVA or suitable capacity as per actual site requirements and as per direction of Engineer in Charge) fully copper winding 3- phase A.C. Supply 50 Hz.input voltage 200 V output voltage 470 V with T/F oil ,power cable & earthing etc.complete in all respect or as per direction of engineer in charge/ as per site requirement. 267 SCADA compatable chlorinatingSystem 268 CE / UL certified Intelligent smart energy meter 269 Motor OperatedActuator with Sluice Valve (150mm) 270 CE / UL certified Electromagnetic flowmeter of size:150mm 271 Digital Soft starter (22 KW) 272 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) (125 Amps) 273 CE / UL certified Hydrostatatic type sub soil water level transmitter 274 CE / UL certified Pressure Transmitter 275 CE / UL certified Surge protector for control panel 276 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 277 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 278 Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse upto meter 279 Fully Automation of TW & OHT through SCADA complete in all respect including mobile based app development and interconnection with MCS and central control room Lucknow with CE&UL Certified PLC/RTU in IP54 including GSM/GPRS based wireless communication with 4G modem for RTU/PLC or as per direction of engineer in charge/ as per site requirement. 280 Automation ofESR Through SCADA For Zone - 3 281 Double Solenoid Flow Control Valve 300 mm dia 282 Double Solenoid Flow Control Valve 250 mm dia 283 CE / UL certified Pressure Transmitter 284 CE / UL certified Electromagnetic flowmeter of size 300 mm dia 285 CE / UL certified Electromagnetic flowmeter of size 250 mm dia 286 Resedual Chlorine Analyser 287 Required Equipments to br install at OHT 288 Motor operated Sluice Valve with Actuator 300 mm dia Size 289 Electromagnetic Flowmeter 300 mm dia Size 290 Ultrasonic Level Sensor 291 Supply, installation,testing & Commissioning of SCADA LCS For Zone 01 to 03 292 Scada LCS (Local Control Station) complete in all respector as per direction of engineer in charge/ as per site requirement. 293 Three Month Trial & Run of TW, LCS, Pumping plant with consumable items till handing over includingwatch & ward .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
19.
Drinking Water Supply and Sanitation #10297779 Price Bid
tender for Rate quotation of different items for implementation of SCADA system at WTP, Boosting Station and all OHR sites (Existing and Proposed) of Surface Water-Based Piped water Supply Scheme, Northern Sector, Part-I at Kaliganj Block, in the District of Nadia,under Nadia Division, P. H. E. Dte. Sl. No. Item Description 1 Intake Jetty 2 Providing Electromagnetic Flowmeter, Protection:IP68, Full bore type Electro Magnetic Flowmeter With Smart Transmitter(Volume Flow rate output:4-20 mA HART Output and Totalizer Pulse Output, Supply:24VDC for (i) Intake site:- Magnetic Flow Meter DN600 3 Repair / Servicing of Pump, Motor, Pressure Gauges, Valves, Crane. 4 Water Treatment Plant:-Flash Mixer, Distribution Chamber, Flocculator, Tube Settler:- 5 Ductile iron double flanged electrically operated Sluice valve generally conforming to IS: 14846, Major construction In Ductile Iron to IS 1865 Gr. 500/7, Seat Rings and spindle nut of gunmetal to IS 318 Gr. LTB 2, non-rising stainless steel AISI 410 spindle, valves suitable for a PN1.0 rating. Flanges drilled to IS 1538 Table 4 & 6 Valves are complete with Rotork Syncropak /AUMA Epak Electrical actuator having inbult reversal starter with position indicator.(i) Tube Settler Sludge Valve 200 mm dia 6 Telescopic arrangement for Sludge waste valve for Mechanical Flocculator 7 New MCC Panel required for new set of motorized actuator valve of Tube Settler 8 Filter Bed :- 9 Motorized Ball Valve(syphon) 10 Magnetic Level Switch 11 Supply, installation, Testing, and Commissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100 MBPS Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc. as required complete In all respect. All as per pre-approved by Engineer In charge. 12 PDB Cum MCC Panel Extension & upgradation for SCADA 13 80 mm Dia Perforated Lateral Pipe repair 14 Repair / Servicing of Air Blower (twin lobe type) of filter bed i.e. motorised actuator valves, suction filter, safety valve, V Belts, V Belt Guard, Suction and Discharge Silencer, NRV, Pressure Gauge, Pulleys, Anti-Vibration Pads, acoustic hood etc. 15 IVC brand Double eccentric design, short body type Electrically operated, double flanged Ductile iron butterfly valves generally confirming IS: 13095, having body, disc end cover in graded Ductile Iron IS:1865 Gr. 400/15, EPDM rubber face ring secured on disc by a SS AISI 304 retaining ring with stainless steel screws, rubber ring seating on a corresponding SS AISI 304 seat in body, Shaft Stainless Steel to AISI: 410. Flanges drilled to IS: 1538, Table - 4 & 6. Valves suitable for a maximum working pressure of 10 kg/cm² (seat test) & body tested to 15 kg/cm2, valves are operated by suitable 3 phase, 415v, 50Hz, AC power supply. ROTORK make syncropak /AUMA Epak electrical actuator having inbuilt reversal starter & position indicator.i) 400 mm Dia for control chember of filter bed 16 Waste Water Collection Sump Pump :- 17 Ductile iron double flanged electrically operated Sluice valve generally conforming to IS: 14846, Major construction In Ductile Iron to IS 1865 Gr. 500/7, Seat Rings and spindle nut of gunmetal to IS 318 Gr. LTB 2, non-rising stainless steel AISI 410 spindle, valves suitable for a PN1.0 rating. Flanges drilled to IS 1538 Table 4 & 6 Valves are complete with Rotork Syncropak /AUMA Epak Electrical actuator having inbult reversal starter with position indicator.(i) 150 mm Dia 18 Panel Replacement& upgradation for SCADA compatibility(i) waste water transfer pump & waste water recycle pump 19 Panel Replacement& upgradation for SCADA compatibilityi) submersible agitator 20 800 X 800 Manually Operated Sluice Gate Repair 21 Level Indicator 22 Supernatent Sump Pump House, Sludge Lagoon:- 23 Level Indicator 24 MCC Panel compatible to SCADA 25 Chemical House:- 26 Cage for Alum slab carry. MOC: SS 316 27 Alum Loading Tray Replacement 28 PE Dosing Pump Repair 29 PE tank Repair 30 Flow Meter & Valves Replacement for SCADA upgradation 31 Dampner 32 VFD (Variable Frequency Drive) for Alum & PE Dosing Pump 33 Y strainer for Alum & PE Dosing Pump 34 Diffuser Pipe line for Alum filling tank 35 MCC Panel Extension & upgradation for SCADA 36 Chlorine Room:- 37 Safety Equipment for Chlorination System i)Canister types gas mask-2 nos, ii) safety shower with eye wash- 1 set, iii)Breathing apparatus with air cylinder 1 no, iv) safety clothing- 2 sets, v) Spare canister for gas mask- 2nos, vi) Gum Boot 2 pair, vii) Residual chlorine test kit- 1 set, viii) Ammonia spray bottle-1 no. ix) Ventilation fan- 2 nos 38 PDB Cum MCC Panel Extension & upgradation for SCADA 39 Pressure Switchi) CWPH DEWATERING SECTION, AIR BLOWER FOR FILTER BED, PIPE GALLERY DEWATERING SECTION, RECIRCULATION PUMP FOR WASTE WATER SUMP, RECIRCULATION PUMP FOR SLUDGE SUMP 40 Level Switchi) CWPH DEWATERING SECTION, PIPE GALLERY DEWATERING SECTION, RECIRCULATION PUMP FOR WASTE WATER SUMP, RECIRCULATION PUMP FOR SLUDGE SUMP 41 Existing & proposed OHR: Safety Equipment required for Existing & Proposed OHR sites:- 42 i)Canister types gas mask-2 nos, ii) safety shower with eye wash- 1 set, iii)Breathing apparatus with air cylinder 1 no, iv) safety clothing- 2 sets, v) Spare canister for gas mask- 2nos, vi) Gum Boot 2 pair, vii) Residual chlorine test kit- 1set, viii) Ammonia spray bottle-1 no. ix) Ventilation fan- 2 nos 43 Ultrasonic Level Transmitter for OHR 44 New MCC Panel required for new set of motorized actuator valve of OHR inlet & Outlet 45 Supernatent Pump House 46 Design, manufacture and supply of 2 M.T. capacity x 12.25 meters span approx. x 6.0 meters lift approx. Single girder construction Hand operated overhead traveling crane incorporated with Indef brand triple spur gear Chain pulley block. All the three motions to the crane shall be manual and to be operated from floor by hand chain. The crane shall be designed for Class I duty indoor operation conforming to IS: 807, IS: 3177 and IS: 3832 as and where applicable. The crane structure shall be supplied duly painted with red lead primer prior to dispatch . Final painting, if required to be carried out by you at your end after installation. The crane shall be tested with 25% overload at our works as per IS: 807-2006. The Rate should be inclusive of Packing and forwarding charges & Freight / delivery charges 47 15 x 2 = 30 mtrs. Design, manufacture and supply of full length sole plate fitted with 40 mm square rail and to be fixed on proposed full length concrete girder by suitable hilty bolts at regular interval . You are requested to provide suitable intermittent insert plates ( at 500 mm apart) maintaining level. 48 Installation charge 49 * Note:- i) Quoted Rate should be exclusive of all taxes.ii) Quoted Rate should include Packing and forwarding charges, Freight/delivery charges, Installation and Commissioning charges, etc. whereas applicable.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
21.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
22.
Drinking Water Supply and Sanitation #10084992 Price Bid
Scada System For Srbc Kc Canal Tgp Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Scada System ( Automation Of Gate Operations ) For Head Regulators Of Srisailam Right Bank Canal ( Srbc ) , Kurnool-Kadapa Canal ( Kc Canal ) And Telugu Ganga Canal System , Local Control System , Supply Of Remote Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc / Rtu / As Per Technical Specifications. , Supply Of Automated Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 8 M Range For Measuring Level / Downstream Discharge In Canal Across The Head / Cross Regulators, Including All Necessary Mast / Cantilever As Per Technical Specification. , Supply Of 3 Phase Vfd Starter Panel For Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Side Looking Acoustic Doppler Based Velocity Meter ( Advm ) For Direct Downstream Discharge Measurement In Head / Cross Regulators Canal System With Bed Width Of As Per The Site Required, Including Integration With Plc / Rtu Complete As Per Technical , Supply Of Automated Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Upstream Level On Head Regulators Of Sunkesula Barrage, Tgp Link Channel & Bcr Additional Head Regulator, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specification , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc / Rtu As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24- Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, And Communication With Scada Control Room Complete As Per Technical Specifications. . , Control Room Equipment’S , Supply, Engineering And Development Of Customized Scada Software For Head / Cross Regulator Automation With Life Time Licensed Version As Per Technical Specifications , Supply Of Industrial Grade Server Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete For Canal Network, As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With 42 Inch Led Display, 1 Kva Ups & 4G / 3G Dongles / Broadbandat Division Monitoring Station With Necessary Accessories As Per Technical Specifications , Supply Of Internet Connection And It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 55” Smart Led Display System For Monitoring Of Canal System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Laptops & 4G / 3G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Canal Automation As Per Technical Specifications , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Canal Scada Control Room Equipment’S As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room , Supply Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Control Room For Establishment Of Canal Scada Control Room Along With Necessary Electrical Fittings As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Andhra Pradesh View Result →
23.
Drinking Water Supply and Sanitation #10079997 Price Bid
Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Of Scada Based Canal Automation For Nagarjun Sagar Right Main Canal Project, Andhra Pradesh Under National Hydrology Project ( Nhp ) Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Of Scada Based Canal Automation For Nagarjun Sagar Right Main Canal Project, Andhra Pradesh Under National Hydrology Project ( Nhp ) , 1 ) Goods As Per Shedule Of Requirements -Local Control System For Nsp Right Main Canal System , Supply Of Remote Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc / Rtu / Datalogger As Per Technical Specifications. , Supply Of Automated Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Level / Downstream Discharge In Canal Across The Head / Cross Regulators, Including All Necessary Mast / Cantilever As Per Technical Specification. , Supply Of Side Looking Acoustic Doppler Based Velocity Meter ( Advm ) For Direct Downstream Discharge Measurement In Head / Cross Regulators Of Nsp Canal System With Bed Width Of As Per The Site Required, Including Integration With Plc / Rtu / Datalogger Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel And Rs485 Port For Sensor Input Type With Gsm And Gprs Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission From Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Datalogger / Rtu With 8 Channel And Rs485 Port For Sensor Input Type With Gsm And Gprs Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission From Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc / Rtu / Datalogger As Per Technical Specifications. , Supply Of Battery-Operated Water Level Monitoring System Using Non-Contact Ultrasonic / Radar Type Water Level Sensor With Gprs / Gsm Communication System For Canals Having Measurement Range Of 0-6 M, Along With Other Ancillary Equipment And All Necessary Mounting Hardware, As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Colour Camera. 6 Or 8 Or 12Mm ( According To Site Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Colour Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24- Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation Complete As Per Technical Specifications. , Supply & Erection Of Pre-Fabricated Green Hut ( Hutment ) ( Size 6X6 And 8 Height ) With M.S. Angle 50X5, 16-Gauge M.S. Sheet, Opening Door, Roof And Floor, Painting Etc. Complete. The Base Measuring 7‘X 7‘ ( 6 Inches Thick ) For Pre-Fabricated Green Hut Should Be Constructed Cement Concrete In M 150 Grade As Per Technical Specification. , Control Room Equipment’S , Supply Of Customized Irrigation Monitoring Software Which Shall Include Scada Software For Real Time Monitoring & Controlling Of Canal Operations, Water Scheduling, Real Time Data Logging For Complete Canal System With Life Time Licensed Version. As Per Technical Specifications. , Supply Of Industrial Gradeserver Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete Forcanal System, As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With 42 Inch Led Display, 1 Kva Ups & 4G / 3G Dongles / Broadband Including Required Software At Division Monitoring Station With Necessary Accessories As Per Technical Specifications , Supply Of Internet Connection Andit Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications. , Supply Of 110” Smart Led Display System Including Installation For Monitoring Of Canal System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Laptops & 4G / 3G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Barrage Automation As Per Technical Specifications , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Canal Scada Control Room Equipment’S As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room. , Supply Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Control Room For Establishment Of Canal Scada Control Room Along With Necessary Electrical Fittings As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.41 Lakh
Boards / Undertakings / PSU No of Bidders 14
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 6.84 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 3.69 Lakh
Boards / Undertakings / PSU No of Bidders 7
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 1.90 Lakh
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 19.47 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 14.80 Lakh
Boards / Undertakings / PSU No of Bidders 15
Contract Date: Ref. Documents Contract Value : 44.64 Lakh
Boards / Undertakings / PSU No of Bidders 3
32.
Power #9674861 AOC
Tender For Procurement Of Emerson Make Analyzer, Sensors And Its Spare Parts Installed At Bop Area At 2X600 Mw Of Sstpp, Dongalia, Khandwa - Conductivity Transmitter, Model No-1056-03-20-30-AN 2 Conductivity Sensor Model No.400-13 3 Conductivity Sensor, 1056-01-20-38-AN, 400-11+3Mts of cell cable+ Flow chamber K=0.01, 0-2 μS/cm 4 Conductivity Sensor, 1056-01-20-38-AN, 400-11+3Mts of cell cable+ Flow chamber (PPCP TEE),K = 0.01, 0-20 μS/cm, Low at 5 μS/cm 5 Conductivity Sensor, 1056-01-21-38-AN, 226-02-56-81,0-100 μS/cm Low at 20 6 Conductivity Transmitter Model No- 1056-01-21-38-HT, 228-02-21-56-61, 0-12 % for NAOH 7 Conductivity Sensor, 1056-01-21-38-HT, 228-02-21-56-61, 0-12 % for NAOH 8 ConductivityTransmitter with Model No- 1056-01-21-38-HT, 228-02-21-56-61,0-15 % for HCL 9 Conductivity Sensor, 1056-01-21-38-HT, 228-02-21-56-61,0-15 % for HCL 10 Chlorine Transmitter, Model No-1056-03-24-38-AN 11 CL Sensor 499ACL-01-54 12 PH Transmitter, Model No-1056-03-22-38-AN 13 PH Sensor, 3900-02-10,RTD-PT100 S/N: H13-5214287-001 14 PH Transmitter, Model No-1056-01-22-38-HT with spare cell & sensor 3900-02-10+ flow chamber 15 Ultrasonic Level TransmitterModel No:3100 Series, ROSEMOUNT, SR No-1208CNBZSC19Calibration:0.3 to 11 Meter 16 Ultrasonic Level Transmitter, Model No:3100 Series, ROSEMOUNT, Model No-1208CNEXBZSE01, Calibration:0-5.5 Mtr. 17 Vacuume Transmitter, Measurement type gauge, Calibration range:(-760 to 0 mmHg), Output 0-20 mA with HART ProtocolSupply- 24 VDCEnclosure- SS316, Having LCD display & zero & span configuration buttons, Medium air, Item code-2051TG1A2B21AB4M5D4Q4
Contract Date: Feb 25, 2026 Contract Value : 59.48 Lakh
Government Departments No of Bidders 1
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 73,160
Government Departments No of Bidders 7
Contract Date: Ref. Documents Contract Value : 5.30 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 19.54 Lakh
Boards / Undertakings / PSU No of Bidders 4
Contract Date: Ref. Documents Contract Value : 5.19 Lakh
Boards / Undertakings / PSU No of Bidders 11
Contract Date: Ref. Documents Contract Value : 2.76 Lakh
Boards / Undertakings / PSU No of Bidders 25
West Bengal View Result →
39.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
40.
Agriculture #9491819 Technical Bid
Supply of Instrument Spares for sugar mill season 2025-2026 - Core Tube, Plunger & Spring for Sugar Solenoid valve 2 5/2 Way, Sugar (Single) Solenoid Valve with coil 3 Spare seal kit for 5/2 Way (Single) Sugar Solenoid valve 4 Core Tube, Plunger & Spring for Sugar Solenoid valve (Single) 5 5/2 Way, Sugar (Double) Solenoid Valve with coil 6 Spare seal kit for 5/2 Way (Double) Sugar Solenoid valve 7 Core Tube, Plunger & Spring for Sugar Solenoid valve (Double) 8 pH/ Conductivity Transmitter 9 pH Sensor 10 Conductivity Sensor 11 Teflon Seat For Globe Valve Size - 50 mm 12 Teflon Seat For Globe Valve Size - 100 mm 13 Teflon Seat For Globe Valve Size - 80 mm 14 Teflon Seat For Globe Valve Size - 150 mm 15 Taflon seat for Globe Valve Size -200mm 16 Taflon Seat for Globe Valve Size - 250mm 17 Taflon Seat for Globe Valve Size - 300mm 18 Control Valve Cylinder Seal kit, Size - 250 mm 19 Control Valve Cylinder Seal kit, Size - 300 mm 20 Gland Packing (Teflon) for Glove Valve 21 Teflon Seat For Butterfly Valve Size-50 mm 22 Teflon Seat For Butterfly Valve Size-80 mm 23 Teflon Seat For Butterfly Valve Size-100 mm 24 Teflon Seat For Butterfly Valve Size-125 mm 25 Teflon Seat For Butterfly Valve Size-150 mm 26 Teflon Seat For Butterfly Valve Size-200 mm 27 Teflon Seat For Butterfly Valve Size-250 mm 28 Teflon Seat For Butterfly Valve Size-300 mm 29 Teflon Seat For Butterfly Valve Size-350 mm 30 Teflon Seat For Butterfly Valve Size-400 mm 31 Control Valve Diaphragm & Body Gasket, Size- 50mm 32 Control Valve Diaphragm & Body Gasket, Size- 80mm 33 Control Valve Diaphragm & Body Gasket, Size- 100mm 34 Control Valve Diaphragm & Body Gasket, Size- 125mm 35 Control Valve Diaphragm & Body Gasket, Size- 150mm 36 Control Valve Diaphragm & Body Gasket, Size- 200mm 37 Control Valve Diaphragm & Body Gasket, Size- 250mm 38 Control Valve Cylinder Seal kit, Size - 350 mm 39 Control Valve Cylinder Seal kit, Size - 400 mm 40 Brix Transmitter With Sensor 41 Teflon sensor Tip/Cap for conductivity electrode for Brix Sensor 42 Teflon Gutka for conductivity electrode for Brix Sensor 43 Teflon sleeve for conductivity electrode for Brix Sensor 44 Rubber & ORing set for conductivity Electrodefor Brix Sensor 45 Conductivity Brix Display card 46 Pressure Switch 47 Pressure Gauge 4 Dial 48 Pressure Gauge 6 Dial 49 Pressure Gauge 6 Dial 50 Pressure Gauge6 Dial 51 Pressure Gauge6 Dial 52 Pressure Gauge 8 Dial Panel Mount 53 Draft Gauge6 Dial 54 Vacuum Gauge 6 Dial 55 Compound Gauge6 Dial 56 Compound Gauge6 Dial 57 Pressure Gauge 58 Pressure Gauge 59 Pressure Gauge for E/P Positioner 60 Pressure Gauge for E/P Positioner 61 Temperature Gauge 62 Temperature Gauge 6 Dial 63 Temperature Gauge 6 Dial 64 RTD Duplex Type Duplex 65 RTD Duplex Type Duplex 66 Load Cell 67 Grip Rubber Belt With Clamp 68 Limit Switch 69 Pneumatic Connector with Flow Control Valve 70 Brass Connector Size- OD-10mm (Male x 12mm Female) 71 Sugar Weighing Controller M/C (Model- Hi-Tech 009) 72 PLC Based fully wired control panel C/W latest Imported Micro Processor controller HT-900 Unipluse. 73 Seal Kit for Cylinder 74 Seal Kit for Cylinder 75 Vibrating Frok Solid Level Switch (for Sugar Bin) 76 Digital Weighing Scale Plateform type with 2 load cell, Capcity-10kg 77 Lift Sensor 78 Donnelly Chute Level Sensor With Mounting Accessories 79 Current Transduser 80 Bearing RTD for Mill Roller 81 Transparnt Fiber Sheet for level sensor mounting 82 Modem For Online System, M2M Logger Remote Monitoring Eco-System With Antenna 83 pH Electrode and pH Sensor with cable (Errand) 84 COD, BOD & TSS Sensor with cable 85 Controller 2020 (Errand) 86 Level transmitter (Ultrasonic Type) 87 PU Tube 8 mm x 5 mm 88 PU Tube 10 mm x 7 mm 89 PU Tube 12 mm x 9 mm 90 PU Connector6mm x 1/4 91 PU Connector10 mm x 3/8 92 PU Connector 8 mm x 1/4 93 PU Connector 8 mm x 3/8 94 PU Connector 10 mm x 1/2 95 PU Connector 8mm (Straight Connector) 96 PU Connector 8 mm x 8 mm (BSP) 97 PU Connector 8 mm x 10 mm (BSP) 98 PI Servo Amplifier 99 Vibration Probe 100 Speed Probe, MPU 101 Turbine TRIP Oil RESET SOV 102 LP RESET SOV 103 ESV SOV 104 Transducer 5m System 105 Hood spray SOV with coil 106 Hood spray Limit switch 107 SIEMENS Positioner 108 TCP Isolator 109 ESV Limit Switch 110 ALTERNATOR temp. Scanner 111 Smart Displacement Type Level Transmitter (Hotwell level transmiter) 112 Smart Displacement Type Level Transmitter (Hotwell level transmiter) 113 TG I/L Steam line thermocouple 114 HP Heater Level Switch 115 MIL Positioner (Control Valve) 116 MIL Position Feedback 117 3ATA Control Valve (Seat gasket,body gasket Seat ring,gland packing) 118 Smart Positioner 119 Feedback Card for smart positioner 120 Smart Positioner (Mesto) 121 Feedback Card for smart positioner 122 ESP Hopper Level Controller & Probe 123 Solenoid valve with coil, 24vdc 124 Quick Exhaust Valve 1/4 125 Quick Exhaust Valve 3/4 126 Pneumatic Cylinder6*12 127 Pneumatic Cylinder sealkit 6x12 128 Control Valve (Angle Type SS Cap Screwed Control Valve) ( 2 Way on/off Valve) 129 Control Valve (Angle Type SS Cap Screwed Control Valve) 130 Quick Exhaust Valve 1/4 131 Quick Exhaust Valve 3/4 132 Selector Switch on/off (for Ash Handling) 133 Diaphragm Operated solenoid valve ( Pulse Valve) (Silo bag filter SOV 24VDC) 134 Diaphargm of Pulse Valve 135 Rotary pneumatic vibrator - Turbine for Conveying System vessel 136 Silo Level Switch Controller & Probe 137 M.F Lubricator 138 Air Filter Regulator 139 Booster & Filter 140 Air Lock Relay 141 Positioner 142 Dayton 1DYP7 Pneumatic Turbine Vibrator 143 Float type level switch, (Anti Scalant Dosing Tank) 144 Vibration Accelerometer Sensor (Motor & Fan Vibration) 145 Spare of CONRTOL VALVE 2(BODY GASKET, SEAT RING, GLAND PAKING & DIAPHRAGM) 146 Spare of CONRTOL VALVE 3(BODY GASKET, SEAT RING, GLAND PAKING & DIAPHRAGM) 147 Spare of CONRTOL VALVE 4(BODY GASKET, SEAT RING, GLAND PAKING & DIAPHRAGM) 148 Spare of CONRTOL VALVE 6(BODY GASKET, SEAT RING, GLAND PAKING & DIAPHRAGM) 149 Spare of CONRTOL VALVE 10(BODY GASKET, SEAT RING, GLAND PAKING & DIAPHRAGM) 150 Spare of CONRTOL VALVE 1 1/4(BODY GASKET, SEAT RING, GLAND PAKING & DIAPHRAGM) 151 Pneumatic Switch (Air Limit Switch) 152 Air Filter Regulator 153 Lubricator 154 Pneumatic Turbine Vibrator for Conveying System vessel 155 Red silicon rubber dome seal 156 Hose Pipe both side threaded connector 157 Hose Pipe both side threaded connector 158 Hose Pipe both side threaded connector 159 Hose Pipe both side threaded connector 160 Hose Pipe both side threaded connector 161 Pneumatic Brass Exhaust Muffler Silencers 162 Pneumatic Brass Exhaust Muffler Silencers 163 Pneumatic Brass Exhaust Muffler Silencers 164 Pneumatic Brass Exhaust Muffler Silencers 165 Oxygen Sensor (Zirconia Sensor) 166 Oxygen Analyzer (Controller) 167 Dust (SPM) Analyzer 168 Ball Valve 169 Ball Valve 170 Ball Valve 171 C-300 Control Processor 172 ODM Diode Oring Module- 40A 173 Analog Input Module 174 Analog Output Module 175 TC/RTD Input Module 176 Digital Input 24V Module 177 24V Digital Output Module 178 Series 8 AI NON Red IOTAPWA, Coated 179 Series 8 HL AO NON Red IOTAPWA, Coated 180 S8 RAM Charger Module (Memory Module) 181 10 Fan 182 Wired Mouse 183 Wired Keyboard 184 Ethernet Cable (Cat-6) 185 Ethernet Connector RJ-45 with sleeve 186 SMPS 187 Pre-Filter for GA-22FFFM 188 Pre-Filter for GA-15FFFM 189 Compressoer Controller for GA-45 With Software 190 Compressoer Controller for GA-37 With Software 191 Compressoer Controller for GA-15 With Software 192 PT for discharge pressure compressor 193 Line Monitoring Relay for Air Compressor 194 Capacitor for dryer 195 Air Filter 196 Oil Filter 197 Oil Separator 198 Panel Filter for Air Compressor CPC-40G 199 Compressoer Controller 200 Union ( SS) Tube Size-10mm 201 SS TUBE 8MM *10MM 202 SS TUBE 6MM *8MM 203 Glass fuse (100 mA) (25mm) 204 Glass fuse (50 mA)(25mm) 205 Glass fuse (2 Amp)(25mm) 206 Glass fuse (1 Amp)(25mm) 207 Glass fuse (5 Amp)(25mm) 208 Glass fuse (10 Amp)(25mm) 209 Glass fuse ( 0.5 Amp/250V)(25mm) 210 Glass fuse ( 250 mA)(25mm) 211 Little fuse for Fluke 15B+ Multimeter 212 FAST-Acting Fuse for Fluke 15B+ Multimeter 213 Battery (Sealed Lead-Acid Battery), Type-EP-130-12 Volt-12V, Capacity-130Ah
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
41.
Agriculture #9489813 Technical Bid
Tender For Supply Of Material Required For Etp Operation - Belt Type Oil & Grease SkimmerSize-2100 x 450 x 300 mm, Belt Size-3500 x 200 x 4.5 mm endBelt material - Elastometer, Motor type - Greared MotorCapacity- 5 HP 20 RPM 3 Phase heavy duty 1.5-2.0 AmpRoller-02 Moc, M.S. Scrapper 02 Both Side, On belt ElectricalProtection inbuild Control Panel 3 EPDM Tube Bubble Diffuser for ETP Airator90 mm Dia x 1000 mm long with all accessories, Model-MF90, 1000E Mucedpm 4 Spares for Online Monitoring System PH Electrode 5 Massibus for flow Monitoring 6 Piezometer complete for recording of ground water level & Temp. with cable other absesones 7 Ultrasonic Flow Transmitter for Effluent Inlet Drain 8 Electronic Flow Meter Dia-6 (EMF Type) Electro Magnetic Flowmeter for Inlet Primary Clarify 9 Electromagnetic Flowmeter for Tubewell Size-10 Dia 10 Electromagnetic Flowmeter 3 11 Pen Type Hand PH Meter(Electronic) 12 Water Distellation Unit Complete 13 T.D.S. Meter 14 D.O. Meter 15 Digital Balance With 01 Mg to 10 gms Accuracy 16 Thermometers 0-110° C 17 B.O.D. Testing Kit 18 C.O.D. Testing Kit 19 B.O.D. Bottles 20 Reagent Bottles 500 Ml 21 PipettleA.5ml 22 B.10ml 23 C.20ml 24 Conical Flask A.250ml 25 B.500ml 26 BeakersA.100ml 27 B.250ml 28 C.500ml 29 Graduated Cylinder A.1000ml 30 B.1000ml 31 C.500ml 32 Burette Graduated A.50ml 33 B.50ml 34 C.100ml 35 Media For Activated Corbon A.Peeble 3 36 B.Peeble 3 37 C.Peeble 1 ½ 38 D.Peeble 1 39 E.Activated Corbon 40 F.Fine Sand 16x32 41 Media For M.G.F. Filter A.Peeble 2 42 B.Peeble 2 43 C.Peeble 1-0.5 44 D.Silica Sand 4x8 45 E.Silica Sand 8x16 46 F.Silica Sand 16x32
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 1
Uttar Pradesh View Result →
42.
Agriculture #9484558 Technical Bid
Supply Of Instrument Spares For Sugar Mill Season 2025-2026 , Solenoid Valve & Coil , Solenoid Valve Seal Kit , E/P Positioner With Feedback (L) , Smart Positioner , E/P Positioner With Feedback ( R) , Positioner Feedback Card , Feedback Valve Position Indicator ( Limit Switch) , Limit Switch , Level Switch, Type-Vibration Froke (Liquid) , Jumbo Display For Ma Indicator , Air Filter Regulator , Air Filter Regulator Complete Repair Kit , Butterfly Valve With Pneumatic Actuator Including Smart Positioner (With Feed Back) For Quard Condenser (Vacuume Application) , Butterfly Valve With Pneumatic Actuator Including Smart Positioner (With Feed Back) For Quard Condenser (Vacuume Application) , Air Filter Regulator With Lubricator , Air Filter Regulator With Lubricator , Complete Repair Kit For Air Filter Regulator With Lubricator , Lubricator , Pneumatic Control Valve , 3/2 Way, Sugar Solenoid Valve With Coil , Spare Seal Kit For 3/2 Way Sugar Solenoid Valve , Core Tube, Plunger & Spring For Sugar Solenoid Valve , 5/2 Way, Sugar (Single) Solenoid Valve With Coil , Spare Seal Kit For 5/2 Way (Single) Sugar Solenoid Valve , Core Tube, Plunger & Spring For Sugar Solenoid Valve (Single) , 5/2 Way, Sugar (Double) Solenoid Valve With Coil , Spare Seal Kit For 5/2 Way (Double) Sugar Solenoid Valve , Core Tube, Plunger & Spring For Sugar Solenoid Valve (Double) , Solenoid Coil Round , Valve Position Feed Back Sensor , Cable For Feed Back Sensor , Male Female Connector For Feed Back Sensor , Solenoid Valve Gang , Pid Controller , Electro Pneumatic Positioner , Current Converter , Conductivity Transmitter , Conductivity Sensor , Ph/ Conductivity Transmitter , Ph Sensor , Conductivity Sensor , Teflon Seat For Globe Valve Size - 50 Mm , Teflon Seat For Globe Valve Size - 100 Mm , Teflon Seat For Globe Valve Size - 80 Mm , Teflon Seat For Globe Valve Size - 150 Mm , Taflon Seat For Globe Valve Size -200Mm , Taflon Seat For Globe Valve Size - 250Mm , Taflon Seat For Globe Valve Size - 300Mm , Control Valve Cylinder Seal Kit, Size - 250 Mm , Control Valve Cylinder Seal Kit, Size - 300 Mm , Gland Packing (Teflon) For Glove Valve , Teflon Seat For Butterfly Valve Size-50 Mm , Teflon Seat For Butterfly Valve Size-80 Mm , Teflon Seat For Butterfly Valve Size-100 Mm , Teflon Seat For Butterfly Valve Size-125 Mm , Teflon Seat For Butterfly Valve Size-150 Mm , Teflon Seat For Butterfly Valve Size-200 Mm , Teflon Seat For Butterfly Valve Size-250 Mm , Teflon Seat For Butterfly Valve Size-300 Mm , Teflon Seat For Butterfly Valve Size-350 Mm , Teflon Seat For Butterfly Valve Size-400 Mm , Control Valve Diaphragm & Body Gasket, Size- 50Mm , Control Valve Diaphragm & Body Gasket, Size- 80Mm , Control Valve Diaphragm & Body Gasket, Size- 100Mm , Control Valve Diaphragm & Body Gasket, Size- 125Mm , Control Valve Diaphragm & Body Gasket, Size- 150Mm , Control Valve Diaphragm & Body Gasket, Size- 200Mm , Control Valve Diaphragm & Body Gasket, Size- 250Mm , Control Valve Cylinder Seal Kit, Size - 350 Mm , Control Valve Cylinder Seal Kit, Size - 400 Mm , Brix Transmitter With Sensor , Brix Transmitter With Sensor , Brix Transmitter With Sensor , Teflon Sensor Tip/Cap For Conductivity Electrode For Brix Sensor , Teflon Gutka For Conductivity Electrode For Brix Sensor , Teflon Sleeve For Conductivity Electrode For Brix Sensor , Rubber & ORing Set For Conductivity Electrodefor Brix Sensor , Electrode Sensor Rod For Brix Sensor , Conductivity Brix Transmitter Card , Conductivity Brix Display Card , Supply Box For Conductivity Transmitter , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Switch , Pressure Gauge 4 Dial , Pressure Gauge 6 Dial , Pressure Gauge 6 Dial , Pressure Gauge 6 Dial , Pressure Gauge 6 Dial , Pressure Gauge 6 Dial , Pressure Gauge6 Dial , Pressure Gauge6 Dial , Pressure Gauge 8 Dial Panel Mount , Draft Gauge6 Dial , Draft Gauge 6 Dial , Vacuum Gauge 6 Dial , Compound Gauge6 Dial , Compound Gauge6 Dial , Compound Gauge6 Dial , Pressure Gauge , Pressure Gauge , Pressure Gauge For E/P Positioner , Pressure Gauge For E/P Positioner , Temperature Gauge , Temperature Gauge , Temperature Gauge , Temperature Gauge 6 Dial , Temperature Gauge 6 Dial , Temperature Gauge 6 Dial , Thermocouple , Rtd For Furnace Travelling Grate , Rtd , Rtd Embedeed Type Duplex , Rtd Duplex Type Duplex , Rtd Duplex Type Duplex , Level Transmitter Flange Mounted , Level Transmitter D.P. Type For Ffe Body , Temperature Transmitter , Temperature Transmitter , Dpt Pressure Transmitter , Pressure Transmitter , Pressure Transmitter , Pressure Transmitter , Pressure Transmitter (Compound) , Load Cell , Solenoid Valves With Coil , Proximity Sensor , Grip Rubber Belt With Clamp , Limit Switch , Pneumatic Connector With Flow Control Valve , Brass Connector Size- Od-10Mm (Male X 12Mm Female) , Sugar Weighing Controller M/C (Model- Hi-Tech 009) , Plc Based Fully Wired Control Panel C/W Latest Imported Micro Processor Controller Ht-900 Unipluse. , Seal Kit For Cylinder , Seal Kit For Cylinder , Vibrating Frok Solid Level Switch (For Sugar Bin) , Digital Weighing Scale Plateform Type With 2 Load Cell, Capcity-10Kg , Lift Sensor , Lift Indicator , Donnelly Chute Level Sensor With Mounting Accessories , Current Transduser , Bearing Rtd For Mill Roller , Transparnt Fiber Sheet For Level Sensor Mounting , Donnelly Chute Level Plc With Addon , Modem For Online System, M2m Logger Remote Monitoring Eco-System With Antenna , Ph Electrode And Ph Sensor With Cable (Errand) , Cod, Bod & Tss Sensor With Cable , Controller 2020 (Errand) , Level Transmitter (Ultrasonic Type) , Load Cell , Pu Tube 8 Mm X 5 Mm , Pu Tube 10 Mm X 7 Mm , Pu Tube 12 Mm X 9 Mm , Pu Connector6mm X 1/4 , Pu Connector10 Mm X 3/8 , Pu Connector 8 Mm X 1/4 , Pu Connector 8 Mm X 3/8 , Pu Connector 10 Mm X 1/2 , Pu Connector 8 Mm X 1/2 , Pu Connector 8Mm (Straight Connector) , Pu Connector Tee ( Thread & Piecen Thread)(8 Mm X 8 Mm X 1/4) , Pu Connector 8 Mm X 8 Mm (Bsp) , Pu Connector 8 Mm X 10 Mm (Bsp) , Pi Servo Amplifier , Vibration Probe , Speed Probe, Mpu , Turbine Trip Oil Reset Sov , Lp Reset Sov , Esv Sov , Feedback Valve Position Indicator , Transducer 5M System , Hood Spray Sov With Coil , Hood Spray Limit Switch , Qcnrv Sov With Coil , Qcnrv Feedback Limit Switch , Dp Gauge , Siemens Positioner , Tcp Isolator , Esv Limit Switch , Alternator Temp. Scanner , Smart Displacement Type Level Transmitter (Hotwell Level Transmiter) , Smart Displacement Type Level Transmitter (Hotwell Level Transmiter) , Tg I/L Steam Line Thermocouple , Hp Heater Level Switch , Mil Positioner (Control Valve) , Mil Position Feedback , 3Ata Control Valve (Seat Gasket,Body Gasket Seat Ring,Gland Packing) , Smart Positioner , Feedback Card For Smart Positioner , Smart Positioner (Mesto) , Feedback Card For Smart Positioner , Positioner With Feedback , Esp Hopper Level Controller & Probe , Solenoid Valve With Coil Single Acting, Coil Voltage-24Vdc , Solenoid Valve With Coil, 24Vdc , Seal Kit Solenoid Valve Single Acting , Pneumatic Limit Switch , Solenoid Valve With Coil, 24Vdc , Quick Exhaust Valve 1/4 , Quick Exhaust Valve 3/4 , Pneumatic Cylinder6*12 , Pneumatic Cylinder Sealkit 6X12 , Control Valve (Angle Type Ss Cap Screwed Control Valve) ( 2 Way On/Off Valve) , Control Valve (Angle Type Ss Cap Screwed Control Valve) , Quick Exhaust Valve 1/4 , Quick Exhaust Valve 3/4 , Selector Switch On/Off (For Ash Handling) , Air Filter & Regulator , Diaphragm Operated Solenoid Valve ( Pulse Valve) (Silo Bag Filter Sov 24Vdc) , Diaphargm Of Pulse Valve , Rotary Pneumatic Vibrator - Turbine For Conveying System Vessel , Silo Level Switch Controller & Probe , M.F Lubricator , Air Filter Regulator , Booster & Filter , Air Lock Relay , Positioner , Volume Booster , Dayton 1Dyp7 Pneumatic Turbine Vibrator , Float Type Level Switch, (Anti Scalant Dosing Tank) , Vibration Accelerometer Sensor (Motor & Fan Vibration) , Spare Of Conrtol Valve 2 (Body Gasket, Seat Ring, Gland Paking & Diaphragm) , Spare Of Conrtol Valve 3 (Body Gasket, Seat Ring, Gland Paking & Diaphragm) , Spare Of Conrtol Valve 4 (Body Gasket, Seat Ring, Gland Paking & Diaphragm) , Spare Of Conrtol Valve 6 (Body Gasket, Seat Ring, Gland Paking & Diaphragm) , Spare Of Conrtol Valve 10 (Body Gasket, Seat Ring, Gland Paking & Diaphragm) , Spare Of Conrtol Valve 1 1/4 (Body Gasket, Seat Ring, Gland Paking & Diaphragm) , Pneumatic Switch (Air Limit Switch) , Air Filter Regulator , Air Filter Regulator , Lubricator , Pneumatic Turbine Vibrator For Conveying System Vessel , Red Silicon Rubber Dome Seal , Hose Pipe Both Side Threaded Connector , Hose Pipe Both Side Threaded Connector , Hose Pipe Both Side Threaded Connector , Hose Pipe Both Side Threaded Connector , Hose Pipe Both Side Threaded Connector , Pneumatic Brass Exhaust Muffler Silencers , Pneumatic Brass Exhaust Muffler Silencers , Pneumatic Brass Exhaust Muffler Silencers , Pneumatic Brass Exhaust Muffler Silencers , Oxygen Sensor (Zirconia Sensor) , Oxygen Analyzer (Controller) , Dust (Spm) Analyzer , Ball Valve , Ball Valve , Ball Valve , C-300 Control Processor , Odm Diode Oring Module- 40A , Analog Input Module , Analog Output Module , Tc/Rtd Input Module , Digital Input 24V Module , 24V Digital Output Module , Series 8 Ai Non Red Iotapwa, Coated , Series 8 Hl Ao Non Red Iotapwa, Coated , S8 Ram Charger Module (Memory Module) , 10 Fan , Mother Board Of Cpu (Operator Computer) , Mother Board Of Cpu (Engineering Computer) , Internal Hard Disk For Computer (Pc Hard Drive) , Wired Mouse , Wired Keyboard , Ethernet Cable (Cat-6) , Ethernet Connector Rj-45 With Sleeve , Smps , Smps , Smps , Smps , Smps , Air Filter For Ga-45 , Oil Filter For Ga-45 , Oil Separator For Ga-45 , Air Filter For Ga-37Fffa , Oil Filter For Ga-37Fffa , Oil Separator For Ga-37Fffa , Air Filter For Ga-15Fffm , Oil Filter For Ga-15Fffm , Oil Separator For Ga-15Fffm , Air Filter For Ga-18Fffm , Oil Filter For Ga-18Fffm , Oil Separator For Ga-18Fffm , Air Filter For Ga-22Fffm , Oil Filter For Ga-22Fffm , Oil Separator For Ga-22Fffm , Oil , Temperature Indicator With Sensor For Ga-15Fffm , Hose Pipe For Ga-22Fffm , Motor Oil Seal Kit For Ga-22Fffm , Pre-Filter For Ga-18Fffm , Pre-Filter For Ga-22Fffm , Pre-Filter For Ga-15Fffm , Pre-Filter For Ga-37 , Pre-Filter For Ga-45 , Filter Kit For Ud60 , Filter Kit For Ud140 , Auto Drain Valve , Main Switch For Air Dryer F230 , Auto Drain Valve For Ga - 37 ( Type- Float) , Compressoer Controller For Ga-45 , Compressoer Controller For Ga-37 , Compressoer Controller For Ga-15 , Pt For Discharge Pressure Compressor , Line Monitoring Relay For Air Compressor , Dryer Controller For F230 , Dryer Selector Switch For F230 , Capacitor For Dryer , Air Filter , Oil Filter , Oil Separator , Panel Filter For Air Compressor Cpc-40G , Compressoer Controller , Thermostat Valve For Ga-37 , Thermostat Valve For Ga-45 , Ss Tee (Size- 1/4 Npt X 1/4 Npt X 1/4 Npt Od) Tube Size- 8Mm , Ss Connectors (Size- 1/4 Npt (M) X 1/4 Od) Tube Size- 8Mm , Union ( Ss)(Size- 1/4 Od X 1/4 Od ) Tube Size-8Mm , Union ( Ss) Tube Size-10Mm , Ss Tube 8Mm *10Mm , Ss Tube 6Mm *8Mm , Glass Fuse (100 Ma) (25Mm) , Glass Fuse (50 Ma)(25Mm) , Glass Fuse (2 Amp)(25Mm) , Glass Fuse (1 Amp)(25Mm) , Glass Fuse (5 Amp)(25Mm) , Glass Fuse (10 Amp)(25Mm) , Glass Fuse ( 0.5 Amp/250V)(25Mm) , Glass Fuse ( 250 Ma)(25Mm) , Little Fuse For Fluke 15B+ Multimeter , Fast-Acting Fuse For Fluke 15B+ Multimeter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
43.
Drinking Water Supply and Sanitation #9460338 Technical Bid
Tender For Baragaon Nagar Panchayat Reorganization Water Supply Scheme Under Amrit 2.0; CIVIL WORK Pump House 2 Supply of all materials labour for Construction of Pumphouse (3.60 x 3.00 x 3.00 M) CUM Chloronating Room (2.80 x 1.50 x 3.00 M) Including all material labour t&p etc Complete as per design & drawing. As per type design of Jal Nigam as per direction of engineer incharge. 3 Supply of all materials labour for Construction of Additional Dozer Room at every zone for DMA (2..50 x 3.00 x 4.00 M) Including all material labour t&p etc Complete as per design & drawing. as per direction of engineer incharge 4 Supply of all materials labour for Construction ofMCS Room (8.00 x 5.00 x 4.00 M) Including all material labour t&p etc Complete as per design & drawing. as per direction of engineer incharge 5 RISING MAIN FOR ZONE 1 AND 2& BYE-PASS ARRANGEMENT 6 Supply of the following sizes of D.I. pipes Class K-9 conforming to latest I.S. 8329/2000 complete in all respect F.O.R. destination including all taxes and insurance including speials. 7 150 mm DI K-9 8 Supply of the following sizes of C.I. Double flanged sluice valves as per I.S. 780/1960 for testing 10kg/Sqcm F.O.R Destination including all taxes and Insurance. 9 150 mm. dia. 10 Excavation in ordinary soil (lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 10 KM from the center of the foundation trenches.as per direction of engineer incharge 11 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within10 KM.as per direction of engineer incharge 12 Carting from the store (up to 8 Km.) The following sizes of D.I. double pipe K-9 and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. com- plate but excluding cost of trenching and cutting of pipes etc. For making of lengths but including making joints. 13 150 mm. dia. 14 Carting of D/F Sluice valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete excluding values and specials required but including the testing etc. complete. 15 150 mm. dia. 16 Supply of all materials, labour T&P etc. required and construct masonry type sluice valves chamber as per type design including supply and materials labour, T&P etc. complete. 17 Supply of all materials, labour, T & P etc. required and construct thrust blocks in RCC 1:2:4 at the bends and below the Valves. 18 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. as per direction of engineer incharge 19 BITUMINOUS ROAD 20 C.C. ROAD 21 Renovation of O.H.T. :- Dismantiling of OHT Flooring , Removing weak concrete hacked, roughended and clean thoroughly of OHT Coloumn for strenthening of OHT Coloumn M S or Iron Work in Plain work Supply of Aporxy resin for Old surface to joint new surface of cement concrete.Jacketing of Cement Concrete 1:1:5:3 Coment Course Sand, Stone Grit Thickness 60 mm Around old coloumn in OHT Including labour T&P etc complete.Construction of RCC foundation of Coloumn Pedestal with 1:1:5:3 cement concrete Dismantling of inner portion old plaster including disposal of malba (vertical wall, cone wall, bottom dome and top dome ).Repairing of Railing of Stair and Balcony with 20mm GI Pipe including changing of old pipe and reflexing new pipe, 12 mm thick Plaster 1:3 Cement and Course sand andwater Proofing Coumpond Chemical over the tank intenal wall and bottom dome to remove the leakage and seepage of tank(vertical wall, cone wall, bottom dome and top dome ). Changing of old & Damaged manhole cover including its fixing Scafoldingfor repairing & Painting of OHT, Dismantling/ Fixing of Inlet, Outlet, Over Flow washout pipe of OHT ,Changing of inlet outlet and washout unserviceable DI Pipe including dismantiling of old pipeand fixing of new pipe 40mm thick PCC (1:2:4) flooring with cement coarse sand and 20mm gauge stone ballast laid in pannels finished with 3mm thick floating coat of neat cement over base concrete 75mm thick consisting of cement, local sand 40mm brick ballast in 1:4:8 including Painting two coats of approved paint Apex Ultima or varnish including supply of all materials, labour and T&P etc required for Proper completion of the work in OHT. as per direction of engineer incharge 22 Design & Supply of all materials, T&P etc required for construction of specified capacity OHT with specified stagingas per following requirements:- 23 Capacity-As Specified in Item No 1.1 to 1.12Grading of OHT- M--35 The food grade epoxy coating of FOSROC / CIEBA GAIKI or reputated brand on the all inside surface area of water container after treatment of water tightness.Stair case- Seperate two column basedRCC staircase and 1 m wide balcony with box type RCC structure at the entrance of the staircase to protect the entry of unwanted persons & locking arrangement with MS door.Railings- 20 mm dia G.I. Pipe (medium quality steel tubes as per IS 1239) railing consisting of 3 rows of with posts height (50x50x6 mm MS angle) (1.0 m) of same pipe around stair case (both sides), balcony & at the top dome periphery, including epoxy 3mm thick coating above base coat, 65mm dia GI pipe (medium quality steel tubes as per IS 1239) ladder with FRP coating from opening of top dome to inside the tank and top of bottom dome. Supply and fixing of CI man hole cover with locking device at opening on the top dome to go inside the tank. Ventilator and Water level indicator - RCC ventilator with SS grill (10 sqm at the spacing of 30 mm) with steel mosquito mesh,electronic digitalwater level indicator with ultrasonic sensor including supply & fixing of solar energy arrangements. Lightening conductor- A good quality lightening conductor covered with PVC casing Vertical pipes- Inlet Pipe - 150 mm, outlet pipe - 250 mm, overflow - 150 mm & washout pipe - 100 mmC.I. D/F pipe as per design criteria upto 1 m beyond the apron, IVC/Kirloskar sluice valve on inlet, out let & at wash out pipe, duck foot bend, puddle collers and bell mouths. 10 mm thick & 150 mm wide S S plate clamp for fixing of verticle pipes with RCC columns (minimum 2 clamps between ends of each pipe). It also includes bye pass arrangement of OHT. The velocity in the pipes shall not exceed 1.5 m/sFlooring, Apron & Drain- 100 mm thick PCC of 1:2:4 & 100 mm thick CC of 1:1:2 with 6 mm thick glass strips not more than 1 sqm area upto 2 m from outer edge of the columns of OHT, drain of size 200 mm x 200 mm with 150 mm thick CC of 1:1:2 including necessary sluice valve chambers and pipe line required for proper drainage of rain water from the campus.Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab..Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab.Two coat apex painting over one coat primer of approved colour of asian / berger paints after fixing of RCC surface with grinder, repair of minor holes, unevenness etc. proper completion of work.Soil bearing capacity- Structure shall be design on the basis of maximum bearing capacity of 8 tonne/sqm or minimum as per actual on the basis of test report of soil bearing capacity. as per direction of engineer incharge 24 Sub Zone of Proposed OHT 18 m Staging ( Including 1m made of Gl or as per site condition ) 25 Proposed OHT Zone-II 400 kl Capacity and 18 m Staging 26 Cost of Testing for bearing capacity of soil for various sites of proposed OHT 27 DISTRIBUTION SYSTEM 28 Supply of following sizes D.I. K-7 pipes,as per I.S.- 8329/2000 or its Latest ammenmendsuitable for pipe with rubber gasket, coupling, coupler, including supply of specials DI DF/DI DS like Tees, Vertical / Horizontal Bend, Gap Pieces required for case of sectional testing etc and making S/S joints all materials T&P etc. all complete. as per I.S. F.O.R. destination including all local cartage etc complete.. ( Rising main Purpose ) 29 250 mm dia D.I.K-7 30 200 mm dia D.I K-7 31 Supply of the following HDPE Pipes as per B.I.S. code no. 4984/2016 or its latest amendment including cost of 1 HDPE coupler per pipe length and all bend , reducer, tee and all type of spacial which are required in Electro fusion joint fitting inclusive of all taxes and duties, 3rd party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges etc. F.O.R. destination etc. complete 32 180 mm dia HDPE PN10/PE100 33 160 mm dia HDPE PN10/PE100 34 140 mm dia HDPE PN10/PE100 35 110 mm dia HDPE PN10/PE100 36 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 37 250 mm dia 38 200 mm dia 39 150 mm dia 40 100 mm dia 41 Supply of the following sizes of C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including all taxes and insurance. 42 80 mm dia 43 Supply of 50 mm dia screwed down type air valve with gun metal seat at site stone including all taxes. 44 Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia duck foot band and 63 mm dia standard make iron coupling with cap and chain etc. complete to IS.369/1995 at site including all taxes. 45 Excavation for pipe line work in ordinary soil(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 10 KM from the center of the foundation trenches. as per direction of engineer incharge 46 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 10 KMas per direction of engineer incharge 47 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. as per direction of engineer incharge 48 INTERLOCKING ROAD 49 BITUMINOUS ROAD 50 C.C. ROAD 51 Carting from store (upto 8 Km) the following sizes of D.1. Pipes (class K-9) and AC pipes (class-15) and specials to the site of work, lowering them in to trenches and taying true to alignment and gradient including testing of pipeline D.I. (K-9) pipes 52 250 mm dia D.I.K-7 53 200 mm dia D.I K-7 54 Carting of following pipes, specials and fittings from site store to site of work, lowering them into trenches, laying true to alignment and gradient, laying and jointing with electro fusion fitting of pipe line including cutting of pipe for making up lengths as required for proper completion of work. 55 180 mm dia HDPE PN10/PE100 56 160 mm dia HDPE PN10/PE100 57 140 mm dia HDPE PN10/PE100 58 110 mm dia HDPE PN10/PE100 59 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 60 250 mm dia 61 200 mm dia 62 150 mm dia 63 100 mm dia 64 Carting of scour valves to the site of workslowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 65 80 mm dia 66 Carting of 50 mm dia screwed down air valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 67 Carting of 80 mm dia flanges fire hydrant of the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 68 Supply of all materials, labour T&P etc. required and construct masonry type sluice / scour valve chamber as per type design including supply and materials labour, T&P etc. complete. 69 Masonry type 70 Supply of all materials, labour T&P Etc. required and construct 350 x 350 x 500 mm size air valve chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 71 Supply of all materials, labour T&P Etc. required and construct 750 x 750 x 1000 mm size fire hydrant chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 72 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main to DMAsincluding supply of all labour, material, T&P etc. complete as per the details given below :-No. of DMAs - 4Total no. of bends & Tee - 120 (considering 3 no. bends & Tee in each DMA)Qty. of concrete - 120 x 0.5 cum = 60 cum. (considering 0.5 cum concrete at each bend) 73 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 74 Brick masonry in cement mortar 1:4 75 12mm thick plaster in cement mortar 1:4 76 Providing and laying in position reinforced cement concrete (mix 1:1.5:3)including batching, mixing, placing, vibrating, curing, formwork, finishing,including cost ofall material (Providing nominal reinforcement @ 0.15% of above itemincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar)) and labour, tools and plants required with transportation, loading, unloading,etc., complete for all leads and lifts etc required for proper completion of the work. 77 Provision for crossing of Nalas (0.5mto 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 78 0.3 - 0.5 m 79 0.5 - 1.0 m 80 1.0 - 1.5 m 81 1.5 - 2.0 m 82 Making House Connection in Distribution main including Dismantling of Road, Supply, carting of Specials lowering them into trenches, fixing them including bailing out of water necessary labour, T&P etc. required for proper completion of worksas per direction of engineer incharge 83 250 mm dia D.I.K-7 84 200 mm dia D.I K-7 85 180 mm dia HDPE PN10/PE100 86 160 mm dia HDPE PN10/PE100 87 140 mm dia HDPE PN10/PE100 88 110 mm dia HDPE PN10/PE100 89 Provision of Shifting water house hold connection. 90 For140 mmto 160 mm dia 91 For110 mm dia 92 Barricading of pipe line trenches by using 2 m high hard MS barricading board 2.5x2.0 M, with red flags, Glow-caution boards, diversion boards & red lights. 93 BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD 94 Construction of compound wall comprising of RCC Columns @ 3.0 m c/c distance with beam at plinth and top, brick work in 1:4 of as per type design including supply of all material, labour, T& P etc complete ( 2m height above plinth level 230 mm thick brick wall )as per direction of engineer incharge 95 Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete, as per direction of engineer incharge 96 Supply and Carting of additional earth required to fill up the site to the required formation level At Zone -I and At Zone -II including leveling dressing ramming with proper compection work completed. as per direction of engineer incharge 97 Provide all materials, labour T&P etc. required for proper completion of work and construction of interlocking approach road in water works campous. At Zone -I and At Zone -IIas per direction of engineer incharge 98 Construction of 250X250 mm size drain at W/W sites At Zone -I and At Zone -IIas per direction of engineer incharge 99 GENERAL RESIDENTIAL QUARTERS 100 Construction of staff quarters (1 G.F) including other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm. As per jal nigam type designas per direction of engineer incharge 101 construction ofStaff Quarter at Zone-I 102 construction ofStaff Quarter at Zone-II 103 E AND M WORKS 104 CONSTRUCTION OF NEW TUBEWELL (ZONE-1) 105 Resistivity and hydrological Survey 106 Transportation from store: 107 Transportation, Erection, Dismantiling of DC/RC/DTH Rig machine 108 Transportation, Erection, Dismantiling of 150 PSI Compressor 109 Transportation, Erection, Dismantiling of 1 Cusec / 3 Cusec OP Unit and Yield test 110 Drilling of Tube well bore : 111 Drilling and reaming of 600mm dia bore from GL to 60 m BGL by DC method 112 Bentonyte Powder Bags 113 Tube Well Assembly : 114 M.S. Tubewell Assembly with all required parts like planin pipe, slotted pipe, rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & per typed design complete in all respect. 115 300mm dia M.S.E.R.W. houseing plain pipe of wall thickness 7.1 mm. 116 Lowering of Tube well Assembly 117 Electrical logging of the bore 118 Lowering of 300mm. Dia M.S. housing pipe G.L. to 59 mtr. BGL 119 Supply of 1.6 to 4.8mm size pea gravel and shrouding of tube well 120 Development of Tube well 121 By Air Compressor 122 Development of Tube well by 150 PSI capacity air compressor 123 By Over Pumping Unit 124 Development of Tube well by OP Unit 125 Chemical & Bacteriological test of water 126 PUMPING MACHINARY TO FEED 400 KL OHT (ZONE-1) 127 SITC of Pumping Plant including, panel, cable, complete in all respect with all required material T&P labour etc. (1000LPM , 61 m Head , 2900RPM, 25 H.P) 128 SITC of Main piping & Valves with 24 mtr. Column pipe, Painting, Tools with wiring of pump house (internal & external) complete in all respect with required material, T&P labour, chain pully and gauges. - 150 mm dia 129 TOOLS (REPUTED MAKE ) IN A TOOL KIT - 1 Set1. Pipe wrenches - 2 No.2. D/E Spanner 22/6 mm - 6 Pcs3. Adjustable wrench 300 mm- 1No.4. Screw driver5. 250 mm- 1No.6. 200 mm - 1No.7. 150 mm- 1No.8. Combination pliers 200 mm- 1No.9. Nose pliers 150 mm - 1No.10.hammer with handle 1 kg.- 1No.11. Line tester (Taparia make)- 1No. 130 SITC of Soft Starter with RS 485 Port- 400 V Class, 18.5 KW, Rating 131 SITC of Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. ( SCADA Compatible ) 132 SITC of Motor Operated Actuator with Sluice Valve - 150 mm size 133 SITC of CE/UL Certified Electromagnetic Flowmeter-150 mm size 134 SITC of Servo voltage stabilizer oil cooled having capacity 40 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% withearthling wire and power cable 135 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 136 125 Amp Rating 137 ElectricalWorksfor Zone-1 138 Electrical System ( For Tubewell ) 139 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of 01 tubewell as follows:- 140 Indoor Lighting 141 Surface Mounting 142 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 143 Suspended Mounting / Surface Mounting 144 36W LED light fixture 2×2 with acrylic / prismatic front cover. 145 Outdoor Lighting 146 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 147 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW & MCS 148 Complete wiring of Pump house with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 149 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 150 Electrical System ( MCS ) 151 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of MCS as follows:- 152 Indoor Lighting 153 Surface Mounting 154 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 155 Suspended Mounting / Surface Mounting 156 36W LED light fixture 2×2 with acrylic / prismatic front cover. 157 Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required.(For MCS) 158 450mm sweep (900/1400 RPM) 159 Outdoor Lighting 160 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 161 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW & MCS 162 Complete wiring of MCS with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 163 Instrumentation Worksfor Zone-1 164 Automation of Proposed OHT ( 400 KL ) with DMA 165 Supply of Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater without sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 166 250 mm dia 167 Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. 168 200 mm 169 Supply of dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 170 200 mm 171 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 172 Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 173 200 mm dia 174 Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 175 Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) 176 Supply of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac+B7Output : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 177 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 178 Master Control Station (MCS) 179 CE & BIS approved manufacturers industrial grade LCD monitor with latest configuration as per specification of size 65 180 Desktop/PC as per spec. mentioned 181 CE/UL approved manufacturers 5 KVA UPS with batteries as spec. mentioned for Computer as per requirement 182 Full development version of required TAGS SCADA Software with customization of software for MCS as per requirement as per specification mentioned. 183 CE & UL approved manufacturers control room PLC with CPU & power supply at MCS in IP65 enclosure as per spec. mentioned 184 CE/UL certified field gateway agent for transfering data from MCS to control room 185 GSM based wireless / broadband/Equipment communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete 186 CE/UL approved manufacturers Firewall for network protection 187 Lightning surge protector for ethernet communication protection 188 CE/UL approved manufacturers industrial grade ethernet switch 189 Mobile App facility system architecture complete. 190 Canon/HP 1018/equivalent Laser printer 191 Security Survelliance IP camera 192 Installation, testing and commissioning with required furniture,Air Conditioner etc 193 Automation of Tubewells (Zone-1) 194 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 195 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 196 CE & UL certified Inteligent Smart Energy Meter 197 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 198 CE & UL certified pressure transmitter 199 CE & UL certified Surge protector for above control panel 200 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for Computer as per requirement 201 CE & UL certified 7 HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 202 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT both. 203 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 204 Installation, commissioning & testing for tubewells 205 AUTOMATION OF DMA (ZONE-1) 206 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 207 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 208 CE/UL Certified Intelligent energy meters 209 CE/UL Certified Surge protector for control panel 210 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 211 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 212 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 213 Cable 214 (i) Complete cabling 215 Security Survelliance IP Camera with recorder (optional) 216 Installation, commissioning & testing 217 CONSTRUCTION OF NEW TUBEWELL ( ZONE-2) 218 Resistivity and hydrological Survey 219 Transportation from store: 220 Transportation, Erection, Dismantiling of DC/RC/DTH Rig machine 221 Transportation, Erection, Dismantiling of 150 PSI Compressor 222 Transportation, Erection, Dismantiling of 1 Cusec / 3 Cusec OP Unit and Yield test 223 Drilling of Tube well bore : 224 Drilling and reaming of 600mm dia bore from GL to 60 m BGL by DC method 225 Bentonyte Powder Bags 226 Tube Well Assembly : 227 M.S. Tubewell Assembly with all required parts like planin pipe, slotted pipe, rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & per typed design complete in all respect. 228 300mm dia M.S.E.R.W. houseing plain pipe of wall thickness 7.1 mm. 229 Lowering of Tube well Assembly 230 Electrical logging of the bore 231 Lowering of 300mm. Dia M.S. housing pipe G.L. to 59 mtr. BGL 232 Supply of 1.6 to 4.8mm size pea gravel and shrouding of tube well 233 Development of Tube well 234 By Air Compressor 235 Development of Tube well by 150 PSI capacity air compressor 236 By Over Pumping Unit 237 Development of Tube well by OP Unit 238 Chemical & Bacteriological test of water 239 PUMPING MACHINARY TO FEED 450 KL OHT (ZONE-2) 240 SITC of Pumping Plant including , panel, cable, complete in all respect with all required material T&P labour etc. (1000LPM , 61 m Head , 2900RPM, 25H.P) 241 SITC of Main piping & Valves with 24 mtr. Column pipe, Painting, Tools with wiring of pump house (internal & external) complete in all respect with required material, T&P labour, chain pully and gauges. - 150 mm dia 242 TOOLS (REPUTED MAKE ) IN A TOOL KIT1. Pipe wrenches - 2 No.2. D/E Spanner 22/6 mm - 6 Pcs3. Adjustable wrench 300 mm - 1 No.4. Screw driver5. 250 mm - 1 No.6. 200 mm- 1 No.7. 150 mm - 1 No.8. Combination pliers 200 mm - 1 No.9. Nose pliers 150 mm - 1 No.10. hammer with handle 1 kg. - 1 No. 243 SITC of Soft Starter with RS 485 Port- 400 V Class, 18.5 KW, Rating 244 SITC of Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. ( SCADA Compatible ) 245 SITC of Motor Operated Actuator with Sluice Valve - 150 mm size 246 SITC of CE/UL Certified Electromagnetic Flowmeter-150 mm size 247 SITC of Servo voltage stabilizer oil cooled having capacity 40 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% withearthling wire and power cable 248 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 249 125 Amp Rating 250 Electrical Worksfor Zone-2 251 Electrical System ( For Tubewell ) 252 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of 01 tubewell as follows:- 253 Indoor Lighting 254 Surface Mounting 255 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 256 Suspended Mounting / Surface Mounting 257 36W LED light fixture 2×2 with acrylic / prismatic front cover. 258 Outdoor Lighting 259 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 260 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW 261 Complete wiring of Pump house with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 262 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 263 Instrumentation Worksfor Zone-2 264 Automation of Proposed OHT ( 450 KL ) with DMA - Zone-2 265 Supply of Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater without sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 266 250 mm dia 267 Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. 268 200 mm 269 Supply of dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 270 200 mm 271 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 272 Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 273 200 mm dia 274 Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 275 Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) 276 Supply of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac+B7Output : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 277 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 278 Automation of Tubewells (Zone-1) 279 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 280 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 281 CE & UL certified Inteligent Smart Energy Meter 282 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 283 CE & UL certified pressure transmitter 284 CE & UL certified Surge protector for above control panel 285 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for Computer as per requirement 286 CE & UL certified 7 HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 287 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT both. 288 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 289 Installation, commissioning & testing for tubewells 290 AUTOMATION OF DMA (ZONE-2) 291 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 292 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 293 CE/UL Certified Intelligent energy meters 294 CE/UL Certified Surge protector for control panel 295 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 296 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 297 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 298 Cable 299 (i) Complete cabling 300 Security Survelliance IP Camera with recorder (optional) 301 Installation, commissioning & testing 302 TRAIL & RUN (Without Electricity) for03 Months Trial & Run for Zone-1,2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
44.
Agriculture #9446365 Technical Bid
supply of Solenoid Seal kit 2 Solenoid Valve & Coil 3 Solenoid Valve Seal kit 4 Solenoid Valve 5 Solenoid Valve Coil 6 E/P Positioner With Feedback (L) 7 Smart Positioner 8 E/P Positioner With Feedback ( R) 9 Positioner Feedback Card 10 Potentiometer for E/P Positioner Make- I&S 11 Feedback Valve Position Indicator ( Limit Switch) 12 Limit Switch 13 Level Switch, Type-Vibration Froke LS 14 Feedback Valve Position Indicator 15 Jumbo Display for mA Indicator 16 Air Filter Regulator 17 Air Filter Regulator Seal kit 18 SMPS 19 SMPS 20 Delval Flow Control Valve, Actuator With Body 21 Butterfly Valve Seat with Pin 22 Repair Kit Actuator 23 Air Filter Regulator with lubricator 24 Pressure Switch 25 Pressure Switch 26 Air Filter Regulator with lubricator and Repair Kit 27 Lubricator 28 Hand Lever Valve 29 Hand Lever Valve, O Ring Set 30 Pneumatic Control Valve and Seal Kit 31 Solenoid Valve with coil & Seal Kit / O Ring Set 32 Solenoid Valve with coil & Seal Kit / O Ring Set 33 Solenoid Valve with coil & Seal Kit / O Ring Set 34 Solenoid Coil Round 35 Disc Rotary Valve With Lever 36 Disc Rotary Valve Repair Kit 37 Volume Booster 38 O Ring Set For Valve 39 Pneumatic Cylinder 40 Rubber Seal Kit For Cylinder 41 Valve Position Feed Back Switch 42 Cable For Feed Back Sensor 43 Male Female Connector For Feed Back Sensor 44 Solenoid Valve Gang 45 Rubber O Ring Kit For Solenoid Valve 46 Plunger Assembly For Solenoid Valve 47 Moving plunger with spring 48 Feed back relay 230 VAC 3C/O 49 Output Relay 24 VDC 2C/O 50 PID Controller 51 Electro Pneumatic Positioner 52 Current Converter 53 24 VDC Power Supply 54 Air Inlet Ball Valve 55 Air Inlet Filter 56 PU Tube, 10mm 57 PU Tube Fittings 1/4 58 PU Tube Fittings 1/2 59 PU Tube Fitting 1/4 60 Coil 230 VAC For Solenoid Valve 61 No massecuite buzzer / indicator 230VAC 62 Conductivity Transmitter 63 Conductivity Sensor 64 pH Transmitter 65 pH Sensor 66 Teflon Seat For Globe Valve Size - 50 mm 67 Teflon Seat For Globe Valve Size - 65 mm 68 Teflon Seat For Globe Valve Size - 80 mm 69 Teflon Seat For Globe Valve Size - 125 mm 70 Teflon Seat For Globe Valve Size - 150 mm 71 Taflon seat for Globe Valve Size -200mm 72 Taflon Seat for Globe Valve Size - 250mm 73 Taflon Seat for Globe Valve Size - 300mm 74 Taflon Seat for Globe Valve Size - 350mm 75 Teflon Seat For Globe Valve Size - 400 mm 76 Control Valve Cylinder Seal kit, Size - 450 mm 77 Control Valve Cylinder Seal kit, Size - 400 mm 78 Control Valve Cylinder Seal kit, Size - 350 mm 79 Control Valve Cylinder Seal kit, Size - 300 mm 80 Control Valve Cylinder Seal kit, Size - 250 mm 81 Control Valve Trim & Diaphragm, Body Gasket 82 Control Valve Trim & Diaphragm, Body Gasket 83 Control Valve Trim & Diaphragm, Body Gasket 84 Control Valve Trim & Diaphragm, Body Gasket 85 Control Valve Trim & Diaphragm, Body Gasket 86 Control Valve Trim & Diaphragm, Body Gasket 87 Control Valve Trim & Diaphragm, Body Gasket 88 Control Valve Trim & Diaphragm, Body Gasket 89 Control Valve Trim & Diaphragm, Body Gasket 90 Teflon Seat For Butterfly Valve Size-50 mm 91 Teflon Seat For Butterfly Valve Size-65 mm 92 Teflon Seat For Butterfly Valve Size-80 mm 93 Teflon Seat For Butterfly Valve Size-100 mm 94 Teflon Seat For Butterfly Valve Size-125 mm 95 Teflon Seat For Butterfly Valve Size-150 mm 96 Teflon Seat For Butterfly Valve Size-200 mm 97 Teflon Seat For Butterfly Valve Size-250 mm 98 Teflon Seat For Butterfly Valve Size-350 mm 99 Teflon Seat For Butterfly Valve Size-400 mm 100 Teflon Seat For Butterfly Valve Size-450 mm 101 Brix Transmitter With Sensor 102 Brix Transmitter With Sensor 103 Teflon sensor Tip/Cap for conductivity electrode for Brix Sensor 104 Teflon Gutka for conductivity electrode for Brix Sensor 105 Teflon sleeve for conductivity electrode for Brix Sensor 106 Rubber & ORing set for conductivity Electrodefor Brix Sensor 107 Electrode sensor rod for Brix Sensor 108 Conductivity Brix Transmitter Card 109 Conductivity Brix Display card 110 Supply box for Conductivity Transmitter 111 Pressure Gauge 4 Dial 112 Pressure Gauge 4 Dial 113 Pressure Gauge 6 Dial 114 Pressure Gauge 6 Dial 115 Pressure Gauge 6 Dial 116 Vacuum Gauge 6 Dial 117 Compound Gauge6 Dial 118 Temperature Gauge 119 Temperature Gauge 120 Temperature Gauge 121 Pressure Gauge (0-10Kg/cm²) for E/P Positioner 122 Pressure Gauge (0-10Kg/cm²) for E/P Positioner 123 RTD 124 Power card & Control card Electronics board (electronic cards) for Rosemount magnetic flow meter 125 Level Transmitter Flange Mounted 126 Level Transmitter D.P. Type for FFE Body 127 Temperature Transmitter 128 Pressure Transmitter 129 Pressure Transmitter (Compound) 130 Load Cell 131 Seal Kit For Cylinder 132 Seal Kit For Cylinder 133 Solenoid Valves 134 Solenoid Valves Seal kit 135 Solenoid Valves Coil 136 Proximity Sensor 137 Pneumatic Cylinder Large Size 138 Pneumatic Cylinder Small Size 139 Seal Kit For Cylinder 140 Seal Kit For Cylinder 141 Grip Rubber Belt With Clamp 142 Limit Switch 143 Sugar Weighing Controller M/C (Model-Hi-Tech 009) 144 Level Switch For Sugar Bin 145 Lift Sensor 146 Lift Indicator 147 Donnelly Chute Level Sensor With Mounting Accessories 148 Isolator 1 I/P - 2 O/P 149 Temperature Scanner 150 Bearing RTD for Mill Roller 151 Pressure Switch 152 Pressure Switch 153 Transparnt Fiber Sheet for level sensor mounting 154 Donnelly Chute Level PLC with addon 155 Rotary Screen Auto Wash Timer 156 SMPS 157 Modem For Online System, M2M Logger Remote Monitoring Eco-System With Antenna 158 pH Electrode and pH Sensor with cable (Errand) 159 COD, BOD & TSS Sensor with cable 160 Controller 2020 (Errand) 161 Level transmitter (Ultrasonic Type) 162 Load Cell 163 PU Tube 8 mm x 5 mm 164 PU Tube 10 mm x 7 mm 165 PU Tube 12 mm x 9 mm 166 PU Connector(6/8 size) 167 PU Tube 6mm 168 PU Connector6mm x 1/4 169 PU Connector10 mm x 3/8 170 PU Connector 8 mm x 1/4 171 PU Connector 8 mm x 3/8 172 PU Connector 10 mm x 1/2 173 PU Connector 8 mm x 1/2 174 PU Connector 8mm (Straight Connector) 175 PU Connector Tee ( Thread & Piecen Thread)(8 mm x 8 mm x 1/4) 176 PU Elbow 8 mm x 1/4 177 PU Tee ( Piecen Thread)(8 mm x 8 mm x 8mm) 178 PU Connector 8 mm x 8 mm(BSP) 179 PU Connector 8 mm x 10 mm(BSP) 180 1/2(F BSP) x 12 mm OD SS Connector Male And Female Thread 181 1/4(F BSP) x 12 mm OD SS Connector Male And Female Thread 182 SS Tee (Size- 1/2 NPT x 1/4 NPT x 1/4 NPT OD) 183 SS Connectors (Size- 1/4 NPT (M) x 1/4 OD) 184 Union ( SS)(Size- 1/4 OD x 1/4 OD ) 185 Axial Vibration Probe (8MM) (Model -VM-5T) 186 ROTOR Before bearring Vibration Probe (8MM)(Model- VM-5K) 187 Speed Probe, MPU(,MODEL NO. 401029/20 MHT) 188 Turbine TRIP OilRESET SOV (BT1100022/100008),Voltage-110VDC,2Way 189 LP RESET SOV (BA03700050),Voltage-110VDC 190 ESV SOV (BT1100031),Voltage-110VDC 191 Transducer 5m System (Model -FK-202F1),S/N -S2SH0035 192 Hood spray SOV (WP8320B174,S/N-DH7760084002),Voltage-24VDC,1/4NPT 193 Hood spray Limit switch (JLSL-1,IS/IEC60947) 194 QCNRV SOV with coil (Model-17002326-41,type-30308-5-2R-M6-S2),24VDC 195 QCNRV Feedback(Model-DXLW15A2-4R) 196 DP Gauge (Range :0-1.6kg),Model-106D4F162FZ,5A,250V AC 197 RTD Embedeed type Duplex,L-40mm,1/4,6mm 198 RTD(BT0880035)L-225mm,connetor-1/2NPT 199 SIEMENS Positioner(MAKE-SIEMENS, Model- SIPART PS2 Hart Positioner, SIGNAL(4-20MA)) 200 TCP Isolator (Type-KFD2-CR4-1.20,Part no. 228758),supply-20-35v DC 201 ESV Limit Switch (CEEEM45) 202 ALTERNATOR temp. Scanner(Model:MICROSCAN-102,S/N:AE0267/18-19),270VAC 203 Hotwell level transmiter(Model-244LD,S/N:244LD-002987)L-1100mm 204 Pressure switch (Range :-1 to -1.5 Bar, Part No.S19-9,Model-GM20102C0K2) 205 Pressure switch (Range-10 to 40Bar,PART NO.S19-37,Model-GM28102B1K2) 206 Pressure switch (Range-0.4 to 4Bar,PART NO.S19-5,Model-GM20102A6K22) 207 Pressure Switch(Range-1.6 to 16 Bar)Model-GM20302A8KWWB,Part No.S19-33 208 Scanner (Model -85XX+,Sr.No.-17031702),Input type-RTDPT-100 209 TG I/L Steam line thermocouple (BT0690062),L-325mm,connector-1NPT 210 HP Heater Level Switch (Model-40HWP/74S/SDW/C3),240v,5A 211 ANNUNCIATOR(Model-MBAS0600) 212 MIL Positioner (Control Valve)(,MODEL NO-8013,SIGNAL(4-20mA)) 213 MIL Position Feedback(,POSITION TX-MIL400L,SUPPLY(10-60VDC),OUTPUT SIGNAL(4-20mA)) 214 RTD(311539120110, SL-184015),8mm,connector-1/2 215 RTD (SL:R161003687)8mm 216 BFP Pump RTD (IN202830,DSR14319).L-110mm,6mm,connector-1/4NPT 217 Vibration Switch(Model:VS-IIV,Sr.No. 7760/3/17),Supply:220VAC, 218 Low oil level Switch(Model:LOLS,Sr.No. : LOLS/781/3/17), Supply-220VAC 219 Isolator Output-4-20MA, 220 3ATA CV (Seat gasket,body gasket Seat ring,gland packing)serial; 173490,model;38-41433, Size-4 221 RTD(, SIZE-Dia- 4MM/ Length- 180mm),connector-1/4adjustable 222 RTD L-340mm,OD-6mm,connector-1NPT(M) 223 RTD L-470mm,OD-6mm,connector-1NPT(M) 224 RTD L-1345mm,OD-14mm,connector-1NPT(M 225 RTD L-700mm,OD-10mm,connector-1NPT(M 226 RTD L-1225mm,OD-14mm,connector-1NPT(M, with thermowell 227 Thermocouple L-1345mm,OD-14mm,,connector-1NPT(M 228 Thermocouple L-465mm,OD-6mm,,connector-1NPT(M 229 Thermocouple L-390mm,OD-6mm,connector-1NPT(M 230 Positioner (ID/FD/SA)(Make-ROTEX)(MAKE-ROTEX, MODEL-RTYX1000L) 231 Feedback Card (ID/FD/SA)(Make-ROTEX)(MAKE-ROTEX, MODEL-RTYX1000L) 232 ESP Hopper Level Controller & Probe(MAKE-EIP, MODEL NO-550,POWER SUPPLY-230VAC) 233 MSP-600-24 Mean well SMPS AC Input 100-240 VAC DC output 24V to 25amp,600w 234 Fine finix bearing RTD PT-100,OD-8mm,Length-200mm 235 Red silicon rubber dome seal ,Size-12inch,standard size 236 Pressure Switch ((0-10 BAR),RT-116 237 Pressure Switch(0.2-7.5 BAR),RT-112 238 Pressure Switch ( (0.3-1.1 BAR),KP-35 239 Pressure Gauge (0-7kg),connector-1/4, pannel type ,dial-2.5 240 Pressure Gauge (0-10kg)connector-1/4, pannel type ,dial-2.5 241 Solenoid Valve(Double acting-24VDC)(ROTEX,VAF413) 242 Solenoid Valve(Single acting-24VDC)(ROTEX,VAF413) 243 Solenoid valve Coil (24V DC)(MAKE-ROTEX,SUPPLY(24VDC)) 244 Air Limit Switch(Make- Rotex, Model-DAF-201-SU-02 , Size- 1/4) 245 Solenoid valve(SVSN-300-4E),24vdc 246 SEAL KIT Solenoid Valve(Single acting-24VDC)(ROTEX,VAF413) 247 SEAL KIT Solenoid valve Coil (24V DC)(MAKE-ROTEX,SUPPLY(24VDC)) 248 Isolator Output-4-20MA, 249 Seal Kit for Quick Exhaust Valve 1/4 (Make- Schrader) 250 Seal Kit for Quick Exhaust Valve 3/4 (Make- Schrader) 251 Pneumatic Cylinder6*12(NSCC8881) 252 Pneumatic Cylinder sealkit 6*12(NSCC8881) 253 Pneumatic Cylinder sealkit 6*12,,PART NO-C063B305) 254 Power Cylinder(,PART NO-C063B305)),6*12 255 Globe Valve(AIRA:Model:AYCV,Type:N/C,Size:50 mm) 256 Globe Valve(AIRA:Model:AYCV,Type:N/C,Size:15 mm) 257 Booster cum Air Filter(Dome Seal Pressure) (PARKER:Model No:ORB25NB) 258 Sealkit Booster cum Air Filter(Dome Seal Pressure) (PARKER:Model No:ORB25NB) 259 Ash Handling System (Regulator& Filter) (MAKE-SHAVO,MODEL-SB60K-4G-M7D-RGLB) 260 Silo bag filter Solenoid valve(MAKE-ROTEX-24VDC,SIZE-1) 261 Diaphargm of Ash Silo Bag Filter Solenoid Valve(MAKE-ROTEX, SIZE-1) 262 Conveying System vessel Pneumatic Vibrator Regulator(MAKE-OLI,TYPE(OT-16),SIZE-1/4) 263 Silo Level Switch Controller &Probe ,PTEF750,Ceramic,230VAC,RF Admitance type 264 M.F Lubricator(SHAVO:MODEL:SF60M-4G-DB,RANGE(0-8KG))SIZE 1/2 265 Air Filter Regulator(Model-11-4SN-200M-M6KA-MB),1/4 266 Booster & Filter(SCHRADER:3340D,Part No.:UID B007) 267 Conductivity sensor for SWAS panel (Model-sp3, SNO. 161658) 268 Air Lock Relay(Make- MIL, Model- 776) 269 PH transmitter for SWAS panel (Model-LXT330, SNO. 170234-39) 270 pH Sensor, Model - 3900-02-10 271 Conductivity Sensor, Model - 400-12 272 FD , SA ,Bypass Damper feedback card(model-YT-1000,SNO. Q0516211),input-4-20ma. 273 Pressure Gauge(0-10Kg/cm2, 1/2 NPT (M)) 274 Pressure Gauge(0-6 Kg/cm2, 1/2 NPT (M)) 275 Pressure Gauge (0-20 Kg/cm2, 1/2 NPT (M)) 276 Pressure Gauge (0-160 Kg/cm2, 1/2 NPT (M)) 277 Pressure Gauge (0-16 Kg/cm2, 1/2 NPT (M)) 278 Pressure Gauge ( 0- 250 kgs/cm2)1/2 NPT (M)) 279 Draft Gauge(0-1000 mmWC, 1/2 NPT (M)) 280 Draft Gauge(0-100 mmWC, 1/2 NPT (M)) 281 Vaccume Gauge((-1 to 1.5 kg/cm2, 1/4 NPT (M)) 282 Vaccume Gauge((-)1 to 1 kg/cm2, 1/4 NPT (M)) 283 Pressure Gauge (0-40Kg/cm2, 1/2 NPT (M)) 284 Pressure Gauge (0-4Kg/cm2, 1/2 NPT (M)) 285 Dayton 1DYP7 Pneumatic Turbine Vibrator Force 1157 IV 16 CFM @ 18psi ,19000 vpm, speed @60psi 286 Pneumatic Power Cylinder 6 287 Temperature Gauge(0-800 DegC,1 NPT (M), Length- 500mm) 288 Temperature Gauge(0-250 DegC, Length- 500mm), 1NPT(M) 289 Temperature Gauge(0-500 DegC, Length- 600mm)1NPT(M 290 Temperature Gauge(0-120 DegC, Length- 600mm)1NPT(M 291 Temp Gauge (0-300 Degre),Length-1225mm,connector-1,adujestable fitting with thermowell 292 Level Indicator ( type-LED / Halogen) 293 Limit Switch(JLSLA,BC9T) 294 Solenoid valve 230v, Size 25 NB,Model C17030977 295 PT for discharge pressure compressor (1089962516,MIDASC08) 296 V- Belt For Compressor(1903361801KE) 297 Flow switch size (40 NB)(250V, 15 A) (ITEM CODE12800,TYPE FM4GP) 298 HOSE PIPE (SNO. TS6387/EN853, 160 BAR , 150Degreec, 1/2 299 Anti-Scalant Dosing Tank Level Switch(Float type level switch)( LENGTH (0-2 mtr) 300 Furnance temp. Indicator(Type- Remote Process Indicator),Supply-220VAC,Input-4 To 20MA 301 Solenoid valves(Model-DS255SR61,PR RANGE-2-10 BAR) 302 Solenoid valves coil ( POWER Supply-24VDC) 303 Proximity Sensors (NBB5-10GM50-E35M,05-40VDC)(NPN TYPE) 304 Pnumatic cylinder Large size (Model no-A12040100O,Max Pressure-10 bar 4S) 305 Seal Kit for cylinder (Model no-A12040100O,Max Pressure-10bar 4S) 306 Seal Kit for cylinder (Model no-A12050050O,Max Pressure-10bar 3S) 307 Pnumatic cylinder Small size(Model no-A12050050O,Max Pressure-10bar 3S) 308 compressoer controller 309 Dryer controller 310 Dryer selector switch 311 Compressoer controller 312 SMPS 24V DC 41.7AMP 313 SMPS 24V DC 25AMP 314 RTD-Furnace Travelling grate Length-12mtrs 315 2 Way on off control valve size-50mm 316 Auto Drain Valve With Timer 317 Pressure Transmitter Range-0 to 10000 MMH2O 318 Capacitor for Dryer fan 20MFD 319 Vibration Bearing prob 25mm/s Serial no-488620 320 CONRTOL VALVE 1A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 321 CONRTOL VALVE 1.5A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 322 CONRTOL VALVE 2A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 323 CONRTOL VALVE 3A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 324 CONRTOL VALVE 4A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 325 CONRTOL VALVE 6A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 326 CONRTOL VALVE 10A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 327 CONRTOL VALVE 1 1/4A. BODY GASKETB. SEAT RINGC. GLAND PAKINGD. DIAPHRAGM 328 Solenoid Valve With Coil 329 2 Way Solinoid Valve With Coil 330 5 Way Solinoid Valve With Coil 331 Limit Switch 332 Air Filter Regulator 333 Air Filter Regulator 334 Lubricator 335 Conveying System vessel Pneumatic Turbine Vibrator 336 Quick Exhaust Valve Diaphragm 3/4 337 Quick Exhaust Valve Diaphragm 1/4 338 Quick Exhaust Valve1/4 339 Quick Exhaust Valve3/4 340 Power Cylinder Repair Kit 341 Hopper level probe with controller 342 Red silicon rubber dome seal 343 Insert Ring 344 “O” Ring for Insert Ring 345 “O” Ring for Spigot Piece 346 Set of Gasket 347 Set of Pneumatic Fittings for Valve Assembly 348 Pneumatic Panel 349 Single Solenoid Valve with coil 350 Seal kit for Single Solenoid Valve 351 1/2” Single Solenoid Valve with coil 352 Seal kit for 1/2 Single Solenoid Valve 353 Pneumatic Switch (Air Limit Switch) 354 Seal Kit for Air Limit Switch 355 Blow Valve 50NB 356 Seal kit for Blow Valve 50NB 357 Repair kit for Blow Valve 50NB 358 Blow Valve 40NB 359 Seal kit for 40NB Blow Valve 360 Repair kit for 40NB Blow Valve 361 Booster cum Air Filter 362 Seal Kit for Booster cum Air Filter 363 Pneumatic Cylinder 6” x 12” 364 Seal kit for 6 X 12 Pneumatic Cylinder 365 Front Clavish for 6 X 12 Pneumatic Cylinder 366 Hose Pipe both side threaded connector 367 Hose Pipe both side threaded connector 368 Hose Pipe both side threaded connector 369 Hose Pipe both side threaded connector 370 Hose Pipe both side threaded connector 371 Pneumatic NRV 1/2 372 Pneumatic NRV 1/4 373 Quick Exhaust Valve 374 Diaphragm for Quick Exhaust Valve 3/4 375 Quick Exhaust Valve 1/4 376 Diaphragm for Quick Exhaust Valve 1/4 377 Bleed Nipple 1/4 x 1.5mm (for Inlet valve ) 378 Bleed Nipple 1/4 x 0.5mm (for Vessel Pressure) 379 Pulse Valve (Size 1),230V AC 380 Diaphragm fo Pulse Valve 1 381 Coil for Pulse Valve 1, 230V AC 382 Brass Filter connector 383 Brass Filter connector 384 Brass Filter connector 385 Selector Swicth 386 Popet Valve, Two way on/off 387 Oxygen Sensor with Analyzer (Controller) 388 Dust (SPM) Analyzer 389 C-300 Controller 390 Ethernet Switch Managed Switch 24 Port Web Smart Switch 391 ODM Diode Oring Module 392 SMPS 393 SMPS 394 SMPS 395 Eaton 8937-HN2 Fibre Optic Extender 396 Analog Input Module 397 Analog Output Module 398 TC/RTD Input Module 399 Digital Input 24V Module 400 24V Digital Output Module 401 Memory Module 402 Ethernet Connector RJ-45 with sleeve 403 Ethernet Cable (Cat-6) 404 Air Filter for GA-45 405 Oil Filter for GA-45 406 Oil Separator for GA-45 407 Air Filter for GA-37FFFA 408 Oil Filter for GA-37FFFA 409 Oil Separator for GA-37FFFA 410 Air Filter for GA-15FFFM 411 Oil Filter for GA-15FFFM 412 Oil Separator for GA-15FFFM 413 Air Filter for GA-18FFFM 414 Oil Filter for GA-18FFFM 415 Oil Separator for GA-18FFFM 416 Air Filter for GA-22FFFM 417 Oil Filter for GA-22FFFM 418 Oil Separator for GA-22FFFM 419 Oil 420 Temperature Indicator with sensor for GA-15FFFM 421 Switch ON/OFF for Air Drier 422 Hose Pipe for Air Compressor GA-37FFFA 423 Hose Pipe for Air Compressor GA-37FFFA 424 Hose Pipe for Air Compressor GA-15FFFM, GP-121218 425 Hose Pipe for Air Compressor GA15-FFFM, GP-121216 426 Hose Pipe for Air Compressor GA-18FFFM 427 Hose Pipe for GA-22FFFM 428 Motor Oil Seal Kit for GA-22FFFM 429 Motor Oil Seal Kit for GA-15FFFM 430 Pre-Filter for GA-18FFFM 431 Pre-Filter for GA-22FFFM 432 Pre-Filter for GA-15FFFM 433 Pre-Filter for GA-37 434 Pre-Filter for GA-45 435 Separator Block Kit for GA-18FFFM 436 Filter kit for UD60 437 Filter kit for UD140 438 Main Switch for Air Dryer F230 439 Auto drain valve with timer SOV 440 Air Filter 441 Oil Filter 442 Oil Separator 443 Panel Filter for Air Compressor CPC-40G 444 Line Monitoring Relay for Air Compressor 445 1/2(F BSP) x 12 mm OD SS Connector Male And Female Thread 446 1/4(F BSP) x 12 mm OD SS Connector Male And Female Thread 447 SS Tee (Size- 1/2 NPT x 1/4 NPT x 1/4 NPT OD) 448 SS Connectors (Size- 1/4 NPT (M) x 1/4 OD) 449 Union ( SS)(Size- 1/4 OD x 1/4 OD ) 450 Little fuse for Fluke 15B+ Multimeter 451 FAST-Acting Fuse for Fluke 15B+ Multimeter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.07 Lakh
Government Departments No of Bidders 5
Maharashtra View Result →
Contract Date: Apr 08, 2026 Contract Value : 2.11 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
50.
Drinking Water Supply and Sanitation #9281098 Technical Bid
Reorganisation Works Of Water Supply Scheme Including Survey, Design, Supply Of All Materials, Labour T&P Complete In All Respect On Turn Key Basis After Completion, Commissioning And Completion Of Trial & Run With Defect Liability Period Of Works Including Har Ghar Jal Certificate & Handing Over To Gram Panchayat For Distt.- Jhansi Under Jal Jeevan Mission Programme Mentioned As Under ( Package-4 ) . 1 Ramnagar Water Supply Reorganisation Scheme 2 Laying Of Rising Main 3 Supply, Laying & Jointing Of Following Sizes ( D.I. K-9 ) Pipes For Rising / Feeder Main Conforming To Latest / Relevant I.S. 8329 / 2000 Specifications With All Jointing Materials Such As D.I. S / S Or Flanged Specials Conforming To Latest / Relevant I.S. Specifications With Rubber Gasket Also, Suitable For D.Ipipes, As Per Is- 8329 / 2000 Or Their Latest Amendment Including F.O.R. Destination And All Taxes And Insurance Etc. With Loading, Unloading And Carting Up To Site Of Work, Also Including Specials For These Pipes And Lowering Them Into The Trenches And Laying True To Alignmentand Gradient And Jointing And Making Inte Connection Etc. Complete ( Including Hydro Testing Of Pipe Lines And Cutting Of Pipes For Making Up The Length But Excluding The Cost Of Trenches ) .All Required For Proper Completion Of Works As Per Direction Of The Engineer. 4 100 Mm Dia Di-K-9 5 150 Mm Dia Di-K-9 6 Supply Up To Site Of Work Of The Following Dia Double Flange Sluice Valve / Scour Valve Confirming For Is 14846 Including Worn Gear Arrangement As Per Test Pressure, Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Upto Store, Unloading And Stacking In All Respect And Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge 7 100Mm 8 150Mm 9 Supply Up To Site Of Work Of The Following Dia Swiss Check Type Non Return ( Reflux ) Valve Confirming For Is 5312 Including Worn Gear Arrangement As Per Test Pressure, Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Upto Store, Unloading And Stacking In All Respectand Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge 10 100Mm 11 150Mm 12 Providing And Supplying Kinetic Double Orifice Type Air Valves Confirming To Is 14845 Specifications Having Small Orifice Elastic Ball Resting On A Gun Metal Orifice Nipple, Large Orifice Vulcanite Ball Seating On Moulded Seat Ring, With Built In Kinetic Features, Isolating Sluice Valve Mounted In Horizontal Position And Operated By Wheel Gearing, Inlet Face And Drilled, Including Insurance, Loading, Unloading, Transportation Upto Stores In All Respect Etc. Complete As Per Instructions Of Engineer. 13 20Mm Dia 14 Excavation In Soil Mixed With Moorumsingle, Kankar And Bazari For Pipe Line Trenches With Lift Upto 1.50M And Lead Upto 50M Including Disposal Of Surplus Earth Within A Distance Of 50 M From Center Of Trenches Also Including Filling Back With Watering And Ramming Of Excavated Earth In To Trenches 15 Same As Above But Excavation In All Type Of Rock 16 Thrust Block 17 R.C.C. With Cement, Coarse Sand And 20Mm Gauge Stone Ballast In Proportion Of1:2:4 In Thrust Blocks Of Pipe Line Excluding Supply Of Reinforcement & Its Bending The Same With 0.50Mm Thick Binding Wire In Position & Necessary Centering And Shuttering Including Curing And Supply Of All Materials, Labour, T&P Etc. Required For Proper Completion Of The Work. 18 Construction Of Following Type Chambers As Per Department Type Design And Drawing Including Heavy Duty R.C.C. Manhole Cover And All Materials, Labour, T&P Etc. Complete For Proper Completion Of Work As Per Instructions Of Engineer 19 Sluice Valve Chambers ( Masonry Type ) 20 Air Valve Chambers ( Masonry Type ) 21 Dismantling And Reinstatement Of Following Type Of Village Road For Laying Of Pipe Line Including Sorting Out Of Serviceable Materials And Disposal Of Unserviceable Materials. 22 Bitumen Road 23 Over Head Tank 24 Construction Of 75 Kl / 16 M Staging Height Over Head Tank As Mentioned Below. Supply Of All Materials Labour T&P Etc. Compete And Construction Of R.C.C. ( M30 Grade ) With Main Components, Instrumentsincluding Cost Of Soil Testing.All The Components Of O.H.T. Will Be Casted In M30 Concrete With Cement, Coarse Sand And Approved Stone Grit As Per I.S. 11682 And I.S.456.Seismic Effects And Wind Load Should Be Taken Into Consideration As I.S. 1893 For Earthquake Resistance And I.S. 875 Part-Iii For Wind Load On Structure ( This Area Is In Seismic Zone Iii And High Damage Risk Zone For Wind ) Proper Ventilator At Top Dome In Circular Shape Along With An R.C.C. Coverand Thickness, Pillar Of Ventilator Should Be Minimum 50 Cm Height. The Space Between Top Dome And R.C.C. Cover Should Be Covered With Mosquito Net Of Standard Quality Alongwith Expanded Metaled Jali, Ultrasonic Type Water Level Indicator And Em Flow Meter And Residual Chlorine Sensor / Transmitter. The Indicator Board Scale Made Of 3Mm Thick M.S. Plate Should Have A Clear Width Of Minimum 25Cm Painted With Good Asian Paint.It Should Also Consists Of 3Mm Brass Wire Rope Minimum 4 Smooth Pulleys About 8 Cm Dia With Guides, 15Cm Dia Copper Ball Float Which Shall Be Completely Water Tight Suitable Pointer Of Brass Etc.Lightening Conductor As Per I.S.S.2309 Of Its Latest Amendments Of Latest Electricity Rules.It Should Consist Proper Elevation Rod With 5 Or More Fork Points Proper Down Conductors Of Prescribed Metal Of Proper Size Prescribed By Iss 2309-1969 And Iss 3013-1966C.I. Manhole Of Min 60X60cm Size Made Of M.S.Channel Section With Adequate Cover Made Of M.S. Sheet Of Minimum 3Mm Thickness Hinged With Manhole With Locking Arrangement. This Manhole Should Be Fix At Top Dome At Proper Place.Supply, Fixing, Jointing Of Following Size Of D.I.D / F Pipes With D.I.D / F Specials Conforming To Is 8329 / 2000 As Vertical Pipes For Inlet, Outlet, Overflow And Washout As Per Latest / Relevant I.S. Specificationswith All Jointing Materials For Proper Completion Of Work Including Other Appurtenant Works And Excavation In All Types Of Soil. Including Out Let Pipe As Max Size Of Distribution System, Inlet Pipes Size As Rising Main Size, Over Flow Pipe As Minimum Rising Main Size & Wash Out Pipe 100 Mm Dia. Supply And Fixing Of Manually Operated Valves / Sluice Valves With Hand Wheels As Per Iss 700 / 1969 Or Its Latest Amendments Class “A” Working Pressure 10 Kg / Cm2 Including Cartage From Its Store To The Site Of Work, Lowering Them Into Trenches, Fixing In Position And Testing Etc. Complete, Construction Of Bed Blocks In 1:2:4 Pcc With Cement, Coarse Sand And Approved Stone Grit Under No Duck Foot Bend To Support The Vertical Pipes. These Bed Blocks Should Supported On The Raft Not On The Soil.Construction Of Sluice Valve Chamber For Above Sluice Valve / Butterfly Valve As Per Departmental Type Design And Drawing Including Supply Of All Labour T&P Complete. Construction Of Washout / Overflow Chamber As Per Departmental Type Design And Drawing.Painting Of All Concrete Surface And Steel Pipe Works With Threecoats Appex ( Exterior Emulsion ) Painting Over A Base Coat Of Birla White Puttyand Anticorrosive Paints.Supply & Laying Of 200 Mm Dia Pvc Pipe As Per I.S.-4985 / 2000 Or As Latest / Relevant Specification Including All Taxes And Insurance Etc.F.O.R. Destination For Disposal Of Water From Overflow And Washout Chamber To Suitable Point Outside The Water Works Compound Including Excavation Of Trenches. Laying Of Pipe Line Etc. Required For Proper Completion Of Works As Per Direction Of The Engineer. 25 Clear Water Reservoir 26 Detailed Survey, Design And Drawing, Construction Of Semi Sunkrcc Cwr ( Circular As Per Site Condition ) Of 20 Kl Capacity Including Free Board, Fixing Of Inlet And Outlet Pipes Of Suitable Sites, Fixing Of M.S. Ladder With Railing Inside The Cwr, R.C.C Ramp And Stair From Gl To Roof Of Cwr, M.H. Covers With Locking Arrangement And Ventilators At Top And Suction Chamber, Automatic Water Level Indicator, Inlet, Out Let, Over Flow Pipes Withpuddle Collars, Required Capacity Of Sluice Valve, Sv Chambler Etc., As Per Is Specifications, Including , Excavation Of Foundation In All Type Of Soil And Rock For Foundation As Required With Continuous Bailing Out Of Water, Including Cutting Of Rock With Special T&P, Making Temporary Approach Roadand Refilling Of Earth Around Cwr, Also Development And Site Clearance As Per Required. Complete Including Supply Of All Material , Labour , T&P Etc. & Constructionclear Water Pump House With Suitable Height With All Door, Window, Gentry Girder With Chain Pulley To Install The Pumping Plants, Openingin Slab With Steel Cage Hinged And Locking Arrangement, Apron Around Cwr And Kota Stone Flooring In Pump House And Top Of Cwr, Construct Pumping Plant Foundation, Fixing Of20 Mm Dia G.I. Piperailing 1.0 M Height In Three Rows At Top Of Cwr, Supply Of All Material Such As Ci Pipes , Specials Etc. Labour For Construct Drainage Arrangement For Emptying The Cwr For Cleaning & Maintenance Etc., Painting Of All Concrete Surface 3 Coat Of Approved Apex Paint , With 2 Coatsbirla White Putty , Painting Of Pipes With Anti-Corrosive Paint, As Perdirection Of Engineer-In Charge Including All Complete. 27 Construction Of Single Room Staff Quarter 28 Single Room Staff Quarter- Construction Of Staff Quarter For Pump Operator, Chaukidar, Pump Attendant As Per Departmental Type Design Attached With Tender Documents Including Excavation In Foundation In Ordinary Soil / Kanker / Morrum / Soft Rock / Hard Rock, Pcc 1:4:8 With Cement Local Sand And 40Mm Gauge Ballastfirst Class Brick Work In 1:4 Cement And Sand Mortar, 12 Mm Thick Plaster In 1:6 Cement And Sand Mortar, Mild Steel Or Iron Work , Supply And Filling Of Carted Earth Up To Plinth Level , 25Mm Thick 1:2:4 Plain Cement Concrete Floor And 45 Cm Wide Apron With 2 Cm Gauge Stone Ballast Laid In Pannels, Finished With 3 Mm Floating Coat Of Neat Cementand 75 Mm Thick Base Concrete 1:4:8 , Supply And Fixing Of 3Mm Thick Glass Strip Of 25 Mm Width In Joint , Ms Angle Iron Chaukhat 40X40x5mm Size , 40 Mm Thick Isi Flush Door Shesham Wood, Window Shutter , Hdpe Tank Of 500 Liter Capacity , Galvanized Mosquito Proof Heavy Quality Iron Wire Gauge 1.50Mm Mesh Over Window With Wood Batten 50X12 Mm And Emulsion Painting In Three Coat Over Two Coats Of Birla White Puty Using Approved Colour And Shade And White Washing Of Ceiling Of Staff Quarters And Internal Wiring Of Staff Quarter As Per Direction Of Eic, Construction Of Septic Tank Sanitary Works With Fixtures, Pipes Etc. And All Type Of Plumbing Work In Kitchen , Bathroom And W / C, With Supply Of All Materials , Labours , Tools And Plants Etc All Complete As Per Direction Of Eic 29 Supply And Fixing Of 3.6 M X 1.50 M Ms Gate Including Fabrication And Supply Of Steel And Construction Of Boundary Wall Pillars Of Size 1.5Mx0.30Mx0.30M With Ornamental Brick Work 115Mm Thk. Around Rcc, As Per Departmental Type Design And Drawing And As Per Specifications Laid Down In The Bid Document, Including Supply Of All Material, Labour, T&P Etc.Required For Proper Completion Of Work As Per Instructions Of Engineer 30 Laying Of Distribution System 31 Supply, Laying & Jointing Of Following Sizes Pipes For Distribution System Conforming To Relevent Specifications With All Jointing Materials, Specials Conforming To Latest / Relevant I.S. Specifications Including F.O.R. Destination And All Taxes And Insurance Etc. With Loading, Unloading And Carting Up To Site Of Work, Also Including Specials For These Pipes And Lowering Them Into The Trenches And Laying True To Alignmentand Gradient And Jointing And Making Inte Connection Etc. Complete ( Including Hydro Testing Of Pipe Lines And Cutting Of Pipes For Making Up The Length But Excluding The Cost Of Trenches ) .All Required For Proper Completion Of Works As Per Direction Of The Engineer. 32 Gi Medium Class 33 65Mm Dia 34 80Mm Dia 35 Di Class K-7 36 100Mm Dia 37 Excavation In Soil Mixed With Moorumsingle, Kankar And Bazari For Pipe Line Trenches With Lift Upto 1.50M And Lead Upto 50M Including Disposal Of Surplus Earth Within A Distance Of 50 M From Center Of Trenches Also Including Filling Back With Watering And Ramming Of Excavated Earth In To Trenches 38 Same As Above But Excavation In All Type Of Rock 39 Supply Up To Site Of Work Of The Following Dia Double Flange Sluice Valve / Scour Valve Confirming For Is 14846 Including Worn Gear Arrangement As Per Test Pressure, Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Upto Store, Unloading And Stacking In All Respect And Lowering Them Into The Already Preparedtrenches, Fixing In Position And Jointingthem With Pipelines And Testing Etc. Completeand Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge. 40 D.I.Sluice Valve 41 80Mm Dia 42 100Mm Dia 43 Providing And Supplying Kinetic Double Orifice Type Air Valves Confirming To Is 14845 Specifications Having Small Orifice Elastic Ball Resting On A Gun Metal Orifice Nipple, Large Orifice Vulcanite Ball Seating On Moulded Seat Ring, With Built In Kinetic Features, Isolating Sluice Valve Mounted In Horizontal Position And Operated By Wheel Gearing, Inlet Face And Drilled, Including Insurance, Loading, Unloading, Transportation Upto Stores In All Respect Etc. Complete As Per Instructions Of Engineer. 44 20Mm Dia 45 Construction Of Following Type Chambers As Per Department Type Design And Drawing Including Heavy Duty R.C.C. Manhole Cover And All Materials, Labour, T&P Etc. Complete For Proper Completion Of Work As Per Instructions Of Engineer 46 Sluice Valve Chambers ( Masonry Type ) 47 Air Valveschambers ( Masonry Type ) 48 Dismantling And Reinstatement Of Following Type Of Road Surfaces For Laying Of Pipe Line Including Sorting Out Of Serviceable Materials And Disposal Of Unserviceable Materials. 49 Interlocking Road 50 Bitumen Road 51 Cc Road 52 Provision For Crossing Of Nalas, Including Shifting Of Telephone Cables Etc. Along The Alignment Of Pipe Line Etc. Complete As Per Instructions Of Engineer -In -Charge. 53 Provision For Crossing Of Nala ( For Upto 5.0 M Wide ) 54 Making Functional Household Tapped Connections ( Fhtc ) From Distribution Line To Outer Wall Of House In 65 To 200 Mm Nominal Dia Pvc Pipe And 50 Mm Dia G.I. To 150 Mm Dia D.I. / G.I. Pipe Distribution Mains ( Existing New ) With Supply Ofg.I. Pipe 15 Mm ( Average 2.00 Mtr ) And H.D.P.E. 20 Mm ( Average 15.00 Mtr Including Specials, Brass Ferrule, Saddle Clamp Etc. Of Suitable Size, T&P Etc. Including Excavation, Laying And Jointing For Proper Completion Of Work As Per Instructions Of Engineer-In-Charge, Fixing Of Ferrule ( 6 Mm Dia ) Of Required Size. Tapping The Main, Includes The Cost Of Bailing Out And Subsequent Back Fill Of Water Main And Cost Of Fitting And Specials Etc Complete And Repair Of Subsequent Leakages Of Joints, Fittings And Specials During Work, Also Including Required Repairing Of Existing Pipe Line Damaged During Dimentalling Old Line Connections Including Dismentaling And Reinstatement Of Any Type Of Road Such As Cc, Interlocking, Boe Or Bitumen Road. Uploading Of Photographs Of Running Fhtcwith Aadhar No. ( Also Submit Xeror Copy Of Aadhar Card To The Department ) Of Benificiery On Www.Ejalshakti.Gov.In Site ( Imis ) And Submiting Of Hard Copy Of Photographs To The Department. 55 Renovation Of Existing Structures 56 Repair Work Of Existing Structures ( Such Asboundary Wall Of W / W Campus And Pump House ) Such As Repair Of Slab, Dismentalling Of Damaged Old Plaster And Replaster Of Thewalls Inner And Outer Face In Proportion 1:6 ( Cement: Sand ) With 12Mm Thick Plaster Cement And Local Sand Mortar In 1:6, Over Existing Brick Work, With Minimum Thickness Not Be Less Than 12Mm Including Supply Of All Materials, Labour, T&P Etc. Required For Proper Completion Of The Work As Per Site Requirement Upto Satisfaction Of Engineer In Charge. Painting Of All Exposed Surface Of Existing Building With Two Or More Coats Of Approved Brand Of Apex Paint Over Two Coat Approved Brand Wall Putty Including Scrapping Of Old Rough Paint Neatly And Homogeneously Including Supply Of All Materials, Labour, T&P Etc. Required For Proper Completion Of The Work As Per Site Requirement Upto Satisfaction Of Engineer In Charge And Roof Treatment Including Water Profing Repair Works In Existing Buildings With Murga Jali In 1:1.5:3 Cement Concrete Of Required Thickness Including Supply Of All Material, Labour Required For Same T&P Etc. As Per Site Requirement Upto Satisfaction Of Engineer In Charge And Providing And Fixing In Position Mild Steel All Panelled Doors And Window Shutters Including Supply And Fixing Of Material For Making Door Shutters By M.S. Sheet 16 Gauge Including Supply And Fixing M.S. Angle 40X40x6 Mm Size Also Including Angle Iron Chaukhat Supply & Fixing Of Oxidized Iron Fittings Etc. Complete At Site As Per Site Requirement Upto Satisfaction Of Engineer In Charge 57 Earth Filling Work For Proper Levelling Of Water Work Site, In Accordance With The Contour Map And Grid Map Of Existing Site Enclosed, Including Levelling, Dressing, Excavation And Filling Of Earth Where Necessary And Also Including All Labour, Materials, T&P Etc. Required For Proper Completion Of Works And Also Including Carriage Of Earth From Within A Distance Of About 8 Km. From The Site Of Works As Per Instructions Of Engineer 58 Site Development - ( 1 ) Leveling And Grading Of The Treatment Plant Site Up To Finished Ground Level. Over Flow Drains And Sewerage Of W / W Campus. Approach / Internal Roads Design For Class A Loading Along With Side Rains. Supply And Fixing Of Fixtures Etc. For External Electrification Along The Approach / Internal Roads And W / W Campus Complete. 59 Pumping Plant For 75 Kl / 16 M Staging Over Head Tank At Ramnagar 60 Supplyandinstallation Of 300Lpm 60M Headvt Pump Set With Suitablecapacityofvhsmotor Included 4.5Mtr Columnassembly Discharge Head Completein All Respect ( 1 W+ Is ) . 61 Supply And Installation Of 10 Hp Starter 62 Supplyandinstallation Of 100 Amp 1 No Incomer, 2 Nos Out Going Lt Control Panel. 63 Supply And Fixing Of16 Sq.Mm 3Core Copper Conductor Lt Cable 64 Sitc Of 100Mmdiasizemainpiping& Valves For Deliveryline & Commonheader Includingband, Tee, Valve Etc Complete 65 Supply And Fixing Of10sq.Mm 3Core Copper Conductor Lt Cable 66 Electromagnitic Flow Meter100 Mm Dia. 67 Supply Of Suitable Capacity I.E. 15 Kva 3 Phase Servo Voltage Stablizerforinputvoltage 240V To500v & Outputvoltage 415±6%Volts.. 68 Supply & Fixing Of Pressure Guage 69 Supply & Fixing Of 2 Tone4 Way Motionhot Crane 70 Internal &Extranal Electrification Of Pumphousecompletein All Respect 71 Supply& Fixing Electromachanicalchlorinatingplant. 72 Supplyandfixing Of Double Pole Earthingincluding Material For Above All Completein All Respect. Electrical Equipment. 73 Supply & Fixing Of Rubber Sheet 74 Watch And Ward Of Pumping Plant 75 Power Connection From Uppcl Without Gst:- 76 3 Phase Lt Power Connection For Above Scheme 77 Sakrar Water Supply Reorganisation Scheme 78 Laying Of Rising Main 79 Supply, Laying & Jointing Of Following Sizes ( D.I. K-9 ) Pipes For Rising / Feeder Main Conforming To Latest / Relevant I.S. 8329 / 2000 Specifications With All Jointing Materials Such As D.I. S / S Or Flanged Specials Conforming To Latest / Relevant I.S. Specifications With Rubber Gasket Also, Suitable For D.Ipipes, As Per Is- 8329 / 2000 Or Their Latest Amendment Including F.O.R. Destination And All Taxes And Insurance Etc. With Loading, Unloading And Carting Up To Site Of Work, Also Including Specials For These Pipes And Lowering Them Into The Trenches And Laying True To Alignmentand Gradient And Jointing And Making Inte Connection Etc. Complete ( Including Hydro Testing Of Pipe Lines And Cutting Of Pipes For Making Up The Length But Excluding The Cost Of Trenches ) .All Required For Proper Completion Of Works As Per Direction Of The Engineer. 80 100 Mm Dia Di-K-9 81 150 Mm Dia Di-K-9 82 200 Mm Dia Di-K-9 83 Supply Up To Site Of Work Of The Following Dia Double Flange Sluice Valve / Scour Valve Confirming For Is 14846 Including Worn Gear Arrangement As Per Test Pressure, Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Upto Store, Unloading And Stacking In All Respect And Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge 84 150Mm 85 200Mm 86 Supply Up To Site Of Work Of The Following Dia Swiss Check Type Non Return ( Reflux ) Valve Confirming For Is 5312 Including Worn Gear Arrangement As Per Test Pressure, Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Upto Store, Unloading And Stacking In All Respectand Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge 87 100Mm 88 150Mm 89 200Mm 90 Providing And Supplying Kinetic Double Orifice Type Air Valves Confirming To Is 14845 Specifications Having Small Orifice Elastic Ball Resting On A Gun Metal Orifice Nipple, Large Orifice Vulcanite Ball Seating On Moulded Seat Ring, With Built In Kinetic Features, Isolating Sluice Valve Mounted In Horizontal Position And Operated By Wheel Gearing, Inlet Face And Drilled, Including Insurance, Loading, Unloading, Transportation Upto Stores In All Respect Etc. Complete As Per Instructions Of Engineer. 91 20Mm Dia 92 Excavation In Soil Mixed With Moorumsingle, Kankar And Bazari For Pipe Line Trenches With Lift Upto 1.50M And Lead Upto 50M Including Disposal Of Surplus Earth Within A Distance Of 50 M From Center Of Trenches Also Including Filling Back With Watering And Ramming Of Excavated Earth In To Trenches 93 Same As Above But Excavation In All Type Of Rock 94 Thrust Block 95 R.C.C. With Cement, Coarse Sand And 20Mm Gauge Stone Ballast In Proportion Of1:2:4 In Thrust Blocks Of Pipe Line Excluding Supply Of Reinforcement & Its Bending The Same With 0.50Mm Thick Binding Wire In Position & Necessary Centering And Shuttering Including Curing And Supply Of All Materials, Labour, T&P Etc. Required For Proper Completion Of The Work. 96 Construction Of Following Type Chambers As Per Department Type Design And Drawing Including Heavy Duty R.C.C. Manhole Cover And All Materials, Labour, T&P Etc. Complete For Proper Completion Of Work As Per Instructions Of Engineer 97 Sluice Valve Chambers ( Masonry Type ) 98 Dismantling And Reinstatement Of Following Type Of Village Road For Laying Of Pipe Line Including Sorting Out Of Serviceable Materials And Disposal Of Unserviceable Materials. 99 Bitumen Road 100 Cc Road 101 Manufacturing, Providing And Supplying Spirally Welded / Erw / Saw / Fabricated M. S. Pipes ( Commercial Quality ) Including Procurements Of Plates, Gas Cutting To Required Size Rolling, Tack Welding Assembling In Suitable Lengths To Form Pipes, Welding On Automatic Welding Machine And Forming ‘V’ Edge On Both Ends Of Pipes Including Railway Freight, Insurance, Unloading From Railway Wagon, Loading Into Truck, Transport To Stores, Unloading, Stacking, Excluding Gst Levied By Goi & Gom In All Respect Etc. Complete As Per Is - 3589 And Is-5504 As Applicable As Per Specifications ( N0 Negative Tolerance In Thickness Is Permissible ) Etc. Required For Proper Completion Of The Work Along With Horizontal Directional Drilling For Steel Duct / Pipes : Installation Of Steel Product Pipe By Hdd Method Including Preparing And Setting Up The Plant And Equipment, Preparing New Pipe / Work Material, Installing New Pipe Work And Commissioning System Or Making The System Ready For Commissioning By Capital Hdd Operation Including, All Related Civil And Mechanical Works Like Excavation, Shoring / Strutting, Etc. Drilling Stringing, Rimming, And Pulling Back The New Pipe Work On The Design Bore Pipe Path Alignment, Proper Disposal Of Drilling Fluid And Backfill Of Site After Completion All-Inclusive As Per Indstt:101-2018: Code Of Practice For Horizontal Direction Drilling Technique Suiting Indian Conditions Etc. Required For Proper Completion Of The Work As Per Instructions Of Engineer Including Licence Fee To Be Paid To Nhai For Granting Permission For Crossing And Laying Of Pipe Across And Along The National Highway 102 Over Head Tank 103 Construction Of 175 Kl / 20 M Staging Height Over Head Tank As Mentioned Below. Supply Of All Materials Labour T&P Etc. Compete And Construction Of R.C.C. ( M30 Grade ) With Main Components, Instrumentsincluding Cost Of Soil Testing.All The Components Of O.H.T. Will Be Casted In M30 Concrete With Cement, Coarse Sand And Approved Stone Grit As Per I.S. 11682 And I.S.456.Seismic Effects And Wind Load Should Be Taken Into Consideration As I.S. 1893 For Earthquake Resistance And I.S. 875 Part-Iii For Wind Load On Structure ( This Area Is In Seismic Zone Iii And High Damage Risk Zone For Wind ) Proper Ventilator At Top Dome In Circular Shape Along With An R.C.C. Coverand Thickness, Pillar Of Ventilator Should Be Minimum 50 Cm Height. The Space Between Top Dome And R.C.C. Cover Should Be Covered With Mosquito Net Of Standard Quality Alongwith Expanded Metaled Jali, Ultrasonic Type Water Level Indicator And Em Flow Meter And Residual Chlorine Sensor / Transmitter. The Indicator Board Scale Made Of 3Mm Thick M.S. Plate Should Have A Clear Width Of Minimum 25Cm Painted With Good Asian Paint.It Should Also Consists Of 3Mm Brass Wire Rope Minimum 4 Smooth Pulleys About 8 Cm Dia With Guides, 15Cm Dia Copper Ball Float Which Shall Be Completely Water Tight Suitable Pointer Of Brass Etc.Lightening Conductor As Per I.S.S.2309 Of Its Latest Amendments Of Latest Electricity Rules.It Should Consist Proper Elevation Rod With 5 Or More Fork Points Proper Down Conductors Of Prescribed Metal Of Proper Size Prescribed By Iss 2309-1969 And Iss 3013-1966C.I. Manhole Of Min 60X60cm Size Made Of M.S.Channel Section With Adequate Cover Made Of M.S. Sheet Of Minimum 3Mm Thickness Hinged With Manhole With Locking Arrangement. This Manhole Should Be Fix At Top Dome At Proper Place.Supply, Fixing, Jointing Of Following Size Of D.I.D / F Pipes With D.I.D / F Specials Conforming To Is 8329 / 2000 As Vertical Pipes For Inlet, Outlet, Overflow And Washout As Per Latest / Relevant I.S. Specificationswith All Jointing Materials For Proper Completion Of Work Including Other Appurtenant Works And Excavation In All Types Of Soil. Including Out Let Pipe As Max Size Of Distribution System, Inlet Pipes Size As Rising Main Size, Over Flow Pipe As Minimum Rising Main Size & Wash Out Pipe 100 Mm Dia. Supply And Fixing Of Manually Operated Valves / Sluice Valves With Hand Wheels As Per Iss 700 / 1969 Or Its Latest Amendments Class “A” Working Pressure 10 Kg / Cm2 Including Cartage From Its Store To The Site Of Work, Lowering Them Into Trenches, Fixing In Position And Testing Etc. Complete, Construction Of Bed Blocks In 1:2:4 Pcc With Cement, Coarse Sand And Approved Stone Grit Under No Duck Foot Bend To Support The Vertical Pipes. These Bed Blocks Should Supported On The Raft Not On The Soil.Construction Of Sluice Valve Chamber For Above Sluice Valve / Butterfly Valve As Per Departmental Type Design And Drawing Including Supply Of All Labour T&P Complete. Construction Of Washout / Overflow Chamber As Per Departmental Type Design And Drawing.Painting Of All Concrete Surface And Steel Pipe Works With Threecoats Appex ( Exterior Emulsion ) Painting Over A Base Coat Of Birla White Puttyand Anticorrosive Paints.Supply & Laying Of 200 Mm Dia Pvc Pipe As Per I.S.-4985 / 2000 Or As Latest / Relevant Specification Including All Taxes And Insurance Etc.F.O.R. Destination For Disposal Of Water From Overflow And Washout Chamber To Suitable Point Outside The Water Works Compound Including Excavation Of Trenches. Laying Of Pipe Line Etc. Required For Proper Completion Of Works As Per Direction Of The Engineer. 104 Clear Water Reservoir 105 Detailed Survey, Design And Drawing, Construction Of Semi Sunkrcc Cwr ( Circular As Per Site Condition ) Of 100 Kl Capacity Including Free Board, Fixing Of Inlet And Outlet Pipes Of Suitable Sites, Fixing Of M.S. Ladder With Railing Inside The Cwr, R.C.C Ramp And Stair From Gl To Roof Of Cwr, M.H. Covers With Locking Arrangement And Ventilators At Top And Suction Chamber, Automatic Water Level Indicator, Inlet, Out Let, Over Flow Pipes Withpuddle Collars, Required Capacity Of Sluice Valve, Sv Chambler Etc., As Per Is Specifications, Including , Excavation Of Foundation In All Type Of Soil And Rock For Foundation As Required With Continuous Bailing Out Of Water, Including Cutting Of Rock With Special T&P, Making Temporary Approach Roadand Refilling Of Earth Around Cwr, Also Development And Site Clearance As Per Required. Complete Including Supply Of All Material , Labour , T&P Etc. & Constructionclear Water Pump House With Suitable Height With All Door, Window, Gentry Girder With Chain Pulley To Install The Pumping Plants, Openingin Slab With Steel Cage Hinged And Locking Arrangement, Apron Around Cwr And Kota Stone Flooring In Pump House And Top Of Cwr, Construct Pumping Plant Foundation, Fixing Of20 Mm Dia G.I. Piperailing 1.0 M Height In Three Rows At Top Of Cwr, Supply Of All Material Such As Ci Pipes , Specials Etc. Labour For Construct Drainage Arrangement For Emptying The Cwr For Cleaning & Maintenance Etc., Painting Of All Concrete Surface 3 Coat Of Approved Apex Paint , With 2 Coatsbirla White Putty , Painting Of Pipes With Anti-Corrosive Paint, As Perdirection Of Engineer-In Charge Including All Complete. 106 Construction Of Single Room Staff Quarter 107 Single Room Staff Quarter- Construction Of Staff Quarter For Pump Operator, Chaukidar, Pump Attendant As Per Departmental Type Design Attached With Tender Documents Including Excavation In Foundation In Ordinary Soil / Kanker / Morrum / Soft Rock / Hard Rock, Pcc 1:4:8 With Cement Local Sand And 40Mm Gauge Ballastfirst Class Brick Work In 1:4 Cement And Sand Mortar, 12 Mm Thick Plaster In 1:6 Cement And Sand Mortar, Mild Steel Or Iron Work , Supply And Filling Of Carted Earth Up To Plinth Level , 25Mm Thick 1:2:4 Plain Cement Concrete Floor And 45 Cm Wide Apron With 2 Cm Gauge Stone Ballast Laid In Pannels, Finished With 3 Mm Floating Coat Of Neat Cementand 75 Mm Thick Base Concrete 1:4:8 , Supply And Fixing Of 3Mm Thick Glass Strip Of 25 Mm Width In Joint , Ms Angle Iron Chaukhat 40X40x5mm Size , 40 Mm Thick Isi Flush Door Shesham Wood, Window Shutter , Hdpe Tank Of 500 Liter Capacity , Galvanized Mosquito Proof Heavy Quality Iron Wire Gauge 1.50Mm Mesh Over Window With Wood Batten 50X12 Mm And Emulsion Painting In Three Coat Over Two Coats Of Birla White Puty Using Approved Colour And Shade And White Washing Of Ceiling Of Staff Quarters And Internal Wiring Of Staff Quarter As Per Direction Of Eic, Construction Of Septic Tank Sanitary Works With Fixtures, Pipes Etc. And All Type Of Plumbing Work In Kitchen , Bathroom And W / C, With Supply Of All Materials , Labours , Tools And Plants Etc All Complete As Per Direction Of Eic 108 Construction Of Boundary Wall 109 Supply Of All Materials T&P Etc. Forconstruction Of Boundary Wall55 M Long , 1.5 M High And 115 Mm Thick Boundary Wall With 230 Mmx 230 Mm Thick Pillar Madein Brick Masonry In 1Cement And 4 Sand Mortar, The Spacing Between Two Pillar Should Not Be More Than 3.0 M C / C And The Depth Of Foundation Should Not Be Less Than 0.6 M, At The Site Of Water Works, Cwr And Esr, Brick Work In Super Structure And Cr Stone Masonary In 1:4 Cement Sand Mortor Below Plinth Level, Rcc Plinth Beam In 1:2:4 Cement, Sand And Stone Grit And Exterior Emulsion Painting In3 Coats Over Base Coat Of Birla White Putty As Per Departmental Type Design And Drawing, And, As Per Specifications Given In The Bid Document Including Supply Of All Materials, Labour T&P Etc. For Proper Completion Of Work As Per Instructions Of Engineer 110 Supply And Fixing Of 3.6 M X 1.50 M Ms Gate Including Fabrication And Supply Of Steel And Construction Of Boundary Wall Pillars Of Size 1.5Mx0.30Mx0.30M With Ornamental Brick Work 115Mm Thk. Around Rcc, As Per Departmental Type Design And Drawing And As Per Specifications Laid Down In The Bid Document, Including Supply Of All Material, Labour, T&P Etc.Required For Proper Completion Of Work As Per Instructions Of Engineer 111 Laying Of Distribution System 112 Supply, Laying & Jointing Of Following Sizes Pipes For Distribution System Conforming To Relevent Specifications With All Jointing Materials, Specials Conforming To Latest / Relevant I.S. Specifications Including F.O.R. Destination And All Taxes And Insurance Etc. With Loading, Unloading And Carting Up To Site Of Work, Also Including Specials For These Pipes And Lowering Them Into The Trenches And Laying True To Alignmentand Gradient And Jointing And Making Inte Connection Etc. Complete ( Including Hydro Testing Of Pipe Lines And Cutting Of Pipes For Making Up The Length But Excluding The Cost Of Trenches ) .All Required For Proper Completion Of Works As Per Direction Of The Engineer. 113 Hdpe Pipe 114 63Mm Dia 115 90Mm Dia 116 Di Class K-7 117 100Mm Dia 118 150Mm Dia 119 200Mm Dia 120 300Mm Dia 121 Excavation In Soil Mixed With Moorumsingle, Kankar And Bazari For Pipe Line Trenches With Lift Upto 1.50M And Lead Upto 50M Including Disposal Of Surplus Earth Within A Distance Of 50 M From Center Of Trenches Also Including Filling Back With Watering And Ramming Of Excavated Earth In To Trenches 122 Same As Above But Excavation In All Type Of Rock 123 Supply Up To Site Of Work Of The Following Dia Double Flange Sluice Valve / Scour Valve Confirming For Is 14846 Including Worn Gear Arrangement As Per Test Pressure, Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Upto Store, Unloading And Stacking In All Respect And Lowering Them Into The Already Preparedtrenches, Fixing In Position And Jointingthem With Pipelines And Testing Etc. Completeand Also Including Supply Of Jointing Materials Etc. Complete .Including Alltaxes And Insurance, As Per Instructions Of Engineer -In -Charge. 124 D.I.Sluice Valve 125 80Mm Dia 126 100Mm Dia 127 150Mm Dia 128 200Mm Dia 129 Providing And Supplying Kinetic Double Orifice Type Air Valves Confirming To Is 14845 Specifications Having Small Orifice Elastic Ball Resting On A Gun Metal Orifice Nipple, Large Orifice Vulcanite Ball Seating On Moulded Seat Ring, With Built In Kinetic Features, Isolating Sluice Valve Mounted In Horizontal Position And Operated By Wheel Gearing, Inlet Face And Drilled, Including Insurance, Loading, Unloading, Transportation Upto Stores In All Respect Etc. Complete As Per Instructions Of Engineer. 130 20Mm Dia 131 Construction Of Following Type Chambers As Per Department Type Design And Drawing Including Heavy Duty R.C.C. Manhole Cover And All Materials, Labour, T&P Etc. Complete For Proper Completion Of Work As Per Instructions Of Engineer 132 Sluice Valve Chambers ( Masonry Type ) 133 Air Valveschambers ( Masonry Type ) 134 Dismantling And Reinstatement Of Following Type Of Road Surfaces For Laying Of Pipe Line Including Sorting Out Of Serviceable Materials And Disposal Of Unserviceable Materials. 135 Interlocking Road 136 Boe Road 137 Bitumen Road 138 Cc Road 139 Provision For Crossing Of Nalas, Including Shifting Of Telephone Cables Etc. Along The Alignment Of Pipe Line Etc. Complete As Per Instructions Of Engineer -In -Charge. 140 Provision For Crossing Of Nala ( For Upto 5.0 M Wide ) 141 Making Functional Household Tapped Connections ( Fhtc ) From Distribution Line To Outer Wall Of House In 65 To 200 Mm Nominal Dia Pvc Pipe And 50 Mm Dia G.I. To 150 Mm Dia D.I. / G.I. Pipe Distribution Mains ( Existing New ) With Supply Ofg.I. Pipe 15 Mm ( Average 2.00 Mtr ) And H.D.P.E. 20 Mm ( Average 15.00 Mtr Including Specials, Brass Ferrule, Saddle Clamp Etc. Of Suitable Size, T&P Etc. Including Excavation, Laying And Jointing For Proper Completion Of Work As Per Instructions Of Engineer-In-Charge, Fixing Of Ferrule ( 6 Mm Dia ) Of Required Size. Tapping The Main, Includes The Cost Of Bailing Out And Subsequent Back Fill Of Water Main And Cost Of Fitting And Specials Etc Complete And Repair Of Subsequent Leakages Of Joints, Fittings And Specials During Work, Also Including Required Repairing Of Existing Pipe Line Damaged During Dimentalling Old Line Connections Including Dismentaling And Reinstatement Of Any Type Of Road Such As Cc, Interlocking, Boe Or Bitumen Road. Uploading Of Photographs Of Running Fhtcwith Aadhar No. ( Also Submit Xeror Copy Of Aadhar Card To The Department ) Of Benificiery On Www.Ejalshakti.Gov.In Site ( Imis ) And Submiting Of Hard Copy Of Photographs To The Department. 142 Renovation Of Existing Structures 143 Heavy Repair Due For Water Tightness, Dismantling Of Unwanted And Construction Of Floor Apron And Semi-Circular Drain At The Ground Level All Around The Tank As Per Site Conditions. Floor Apron To Be Provided 0.50 M Beyond The Outer Edge Of The Balcony, Semi Circular Drain Of 200 Mm Dia All Around The O.H.T. Flooring Consisting Of Cement Concrete With 20Mm Gauge Approved Stone Grit, Coarse Sand, Cement In Proportion Of 1:2:4 Including Dismantling Of Old Repairableall Material, Labour, T&P Etc Also Repairing Of Chambers Under Tank Structure As Sluice Valve Chamber, Wash Out Chamber , Bye Pass Chamber And Over Flow Chamber And Supply Of Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer Incharge In Existing Over Head Tank , Supply And Fixing Ventilator Jali At O.H.T. / Cwr Including Repairing Of The Ventilator And Fixing The Same Properly Including Supply Of All Material, Labour, T&P Etc., Supply And Fixing Of New Lightening Conductor Consisting Of Elevation Rod, Down Conductor, Earth Plate Complete With Marked Scale Of The O.H.T. Including Cutting Of Hole For Cleats To Fix The Same Properly And Including Supply Of All Material, Labour, T&P Etc. And Fixing The Appliances In The Cleats With Screw Or Nales Etc. All Complete, Painting Of Outer Surface Of Oht With 3 Coats Of Approved Wheather Proof Paint ( Like Apex Etc. ) As Per Departmentalcolour With Two Coat Birla White Putty. Railing Of Stair Case And Balcony With Iron Post And Two Raws Of G.I. Pipe 20Mm Dias And Painting The Iron Work In Small Area With One Coat Of Anti Corrosive Primer Coat And Two Coat Of Approved Enamel Paint Also Writing Of Programme Name With Scheme Name & Tank Capacity On Tank Wall As Per Direction & Up To Satisfaction Of Engineer In-Charge. 144 Repair Work Of Existing Structures ( Such Asboundary Wall Of W / W Campus And Pump House ) Such As Repair Of Slab, Dismentalling Of Damaged Old Plaster And Replaster Of Thewalls Inner And Outer Face In Proportion 1:6 ( Cement: Sand ) With 12Mm Thick Plaster Cement And Local Sand Mortar In 1:6, Over Existing Brick Work, With Minimum Thickness Not Be Less Than 12Mm Including Supply Of All Materials, Labour, T&P Etc. Required For Proper Completion Of The Work As Per Site Requirement Upto Satisfaction Of Engineer In Charge. Painting Of All Exposed Surface Of Existing Building With Two Or More Coats Of Approved Brand Of Apex Paint Over Two Coat Approved Brand Wall Putty Including Scrapping Of Old Rough Paint Neatly And Homogeneously Including Supply Of All Materials, Labour, T&P Etc. Required For Proper Completion Of The Work As Per Site Requirement Upto Satisfaction Of Engineer In Charge And Roof Treatment Including Water Profing Repair Works In Existing Buildings With Murga Jali In 1:1.5:3 Cement Concrete Of Required Thickness Including Supply Of All Material, Labour Required For Same T&P Etc. As Per Site Requirement Upto Satisfaction Of Engineer In Charge And Providing And Fixing In Position Mild Steel All Panelled Doors And Window Shutters Including Supply And Fixing Of Material For Making Door Shutters By M.S. Sheet 16 Gauge Including Supply And Fixing M.S. Angle 40X40x6 Mm Size Also Including Angle Iron Chaukhat Supply & Fixing Of Oxidized Iron Fittings Etc. Complete At Site As Per Site Requirement Upto Satisfaction Of Engineer In Charge 145 Earth Filling Work For Proper Levelling Of Water Work Site, In Accordance With The Contour Map And Grid Map Of Existing Site Enclosed, Including Levelling, Dressing, Excavation And Filling Of Earth Where Necessary And Also Including All Labour, Materials, T&P Etc. Required For Proper Completion Of Works And Also Including Carriage Of Earth From Within A Distance Of About 8 Km. From The Site Of Works As Per Instructions Of Engineer 146 Site Development - ( 1 ) Leveling And Grading Of The Treatment Plant Site Up To Finished Ground Level. Over Flow Drains And Sewerage Of W / W Campus. Approach / Internal Roads Design For Class A Loading Along With Side Rains. Supply And Fixing Of Fixtures Etc. For External Electrification Along The Approach / Internal Roads And W / W Campus Complete. 147 Pumping Plant For Cwr To Cwr 148 Supplyandinstallation Of 1800Lpm 55M Headvt Pump Set With Suitablecapacityofvhsmotor Included 4.5Mtr Columnassembly Discharge Head Completein All Respect ( 1 W+ Is ) . 149 Supply And Installation Of 35 Hp Starter 150 Supplyandinstallation Of 200 Amp 1 No Incomer, 2 Nos Out Going Lt Control Panel. 151 Supply And Fixing Of35sq.Mm 3.5 Core Aluminium Conductor Lt Cable For Lt Panal 152 Sitc Of 150Mmdiasizemainpiping& Valves For Deliveryline & Commonheader Includingband, Tee, Valve Etc Complete 153 Supply And Fixing Of16sq.Mm 3Core Copper Conductor Lt Cable For Starter 154 Electromagnitic Flow Meter150 Mm Dia. 155 Supply Of Suitable Capacity I.E. 60 Kva 3 Phase Servo Voltage Stablizerforinputvoltage 240V To500v & Outputvoltage 415±6%Volts.. 156 Supply & Fixing Of Pressure Guage 157 Supply & Fixing Of 2 Tone4 Way Motionhot Crane 158 Internal &Extranal Electrification Of Pumphousecompletein All Respect 159 Supplyandfixing Of Double Pole Earthingincluding Material For Above All Completein All Respect. Electrical Equipment. 160 Supply & Fixing Of Rubber Sheet 161 Watch And Ward Of Pumping Plant 162 Pumping Plant For Cwr To Oht 163 Supplyandinstallation Of 550Lpm Pump For 250 Kl / 16 M Staging Oht 164 Supplyandinstallation Of 550Lpm 65M Headvt Pump Set With Suitablecapacityofvhsmotor Included 4.5Mtr Columnassembly Discharge Head Completein All Respect ( 2W+ Is ) . 165 Supply And Installation Of 15 Hp Starter 166 Supplyandinstallation Of 200 Amp 1 No Incomer, 7 Nos Out Going Lt Control Panel. 167 Supply And Fixing Of35sq.Mm 3.5 Core Aluminium Conductor Lt Cable For Lt Panal 168 Sitc Of 150Mmdiasizemainpiping& Valves For Deliveryline & Commonheader Includingband, Tee, Valve Etc Complete 169 Supply And Fixing Of16sq.Mm 3Core Copper Conductor Lt Cable For Starter 170 Electromagnitic Flow Meter150 Mm Dia. 171 Supply Of Suitable Capacity I.E. 75 Kva 3 Phase Servo Voltage Stablizerforinputvoltage 240V To500v & Outputvoltage 415±6%Volts.. 172 Supply & Fixing Of Pressure Guage 173 Supply & Fixing Of 2 Tone4 Way Motionhot Crane 174 Internal &Extranal Electrification Of Pumphousecompletein All Respect 175 Supply& Fixing Electromachanicalchlorinatingplant. 176 Supplyandfixing Of Double Pole Earthingincluding Material For Above All Completein All Respect. Electrical Equipment. 177 Supply & Fixing Of Rubber Sheet 178 Watch And Ward Of Pumping Plant 179 Supply And Installation Of 450 Lpm Pumps For 175 Kl / 20 M Staging Oht 180 Supplyandinstallation Of 450Lpm 65M Headvt Pump Set With Suitablecapacityofvhsmotor Included 4.5Mtr Columnassembly Discharge Head Completein All Respect ( 2W+ Is ) . 181 Supply And Installation Of 10 Hp Starter 182 Sitc Of 150Mmdiasizemainpiping& Valves For Deliveryline & Commonheader Includingband, Tee, Valve Etc Complete 183 Supply And Fixing Of10sq.Mm 3Core Copper Conductor Lt Cable For Starter 184 Supply & Fixing Of Pressure Guage 185 Electromagnitic Flow Meter150 Mm Dia. 186 Supply& Fixing Electromachanicalchlorinatingplant. 187 Supply And Fixing Of Solar Light 188 Power Connection From Uppcl Without Gst :- 189 3 Phase Lt Power Connection For Above Scheme
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
TenderDetail
Loading tenders