View Bid Results For Tubular Structure Tenders

We found 2106 Bid Results related to tubular structure tenders. You can find Contractor details who won tubular structure tenders along with contract details in Bid awards announcements section.

Filters
Stage
1292
555
259
Tender Publishing Platform
137
1969
State / UT
37
289
269
239
238
208
95
89
86
79
67
59
56
44
37
35
33
33
17
16
14
13
13
13
12
10
7
7
6
5
5
4
3
1
1
1
1
1
Contract Value
859
389
607
246
Publish Date
5
0
0
0
0
Sector
29
413
341
335
287
149
124
107
47
42
41
38
21
20
19
16
14
13
11
11
8
8
8
7
7
6
6
3
2
2
Ownership
7
1110
343
331
295
16
6
5
Within keyword
Active filters:
Showing 1–43 of 2106 tenders matching your filters
1.
Science and Technology #11440503 Technical Bid
Tender for Earth Work , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lif. , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Cement Concrete (Cast In Situ) , Providing And Laying In Position Excluding Cement Concrete Of Level: Specified Grade The Cost Of Centering And Shuttering - All Work Up To Plinth 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Ill) Derived From Natural Sources: 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor Etc., Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing: 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement.All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Stone Work , Coursed Rubble Masonry (Second Sort) With Hard Stone In Foundation & Plinth With :Cement Mortar 1:6(1 Cement : 6 Coarse Sand) , Cladding Work , Providing Edge Moulding To 18Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge,Granite Work , Wood And P. V. C. Work , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing 40X5 Mm Flat Iron Hold Fast 400 Mm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 300X100x150 Mm 1:3:6 Mix (1 Cement: 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size). , Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 36 Kg To 80 Kg And Door Width From 701 Mm To 1000 Mm), With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Twin Rubber Stopper , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Wire Mesh / Glazing Of Plain/ Toughened/ Laminated/ Double Glass Unit With / Without High Performance Coatings As Per Design Requirements And Conforming To Is: 3548 & Is: 16231 Shall Be Paid Separately. Note:- Structural Design Proof Checked From A Government Engineering Institute, To Be Provided By The Manufacturer For (I) Sites With Basic Wind Speed 45 M/Sec As Per Is 875 - Part 3 (Ii) Sites With Structure Height More Than 20M For All Wind Speedscasement Window Double Panels With Fixed Mullion With S.S. 304 Friction Hinges As Per Size And Weight Of Sash, Multi-Point Locking System, Zinc Alloy (Zamak) Powder Coated Handles.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above) & Sash (39 Mm & Above) X (60 Mm & Above) & Mullion (39 Mm & Above) X (60 Mm & Above). (Height Upto 1.2 Metre). , Steel Work , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works , Flooring , Providing And Laying Vitrified Tiles In Floor In Diferent Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Double Charge Vitrified Tile Polished Finish Of Size Of Tile 600 X 600 Mm , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Finishing , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix:1:4(1 Cement: 4 Coarse Sand) , 6 Mm Cement Plaster 1:3 (1 Cement: 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams. , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , 12 Mm Thick Plain Cement Mortar Bands In Cement Mortar 1:4 (1 Cement: 4 Fine Sand):Moulded Band , Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Itr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade :Two Or More Coats On New Work , French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , Wall Painting With Acrylic Emulsion Paint, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour.Two Coats , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Dismantling And Demolishing , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.Nominal Concrete 1:3:6 Or Richer Mix (Including Equivalent Design Mix) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Aluminium Work , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete.Upto 5 Mm Depth And 5 Mm Width , Market Rate Items , Provinding Precast Cement Concrete Solid Block Masonry Including Hoisting And Setting In Position With Cement Mortar 1:6 (Cement :6 Coarse Sand) Completed As Per The Direction Of Engineer In Charge As Per Site Condition , Providing And Fixing 5 Mm Thick Clear Transparent Acrylic Sheet Of Approved Brand And Manufacture For Fixed Curved Portions In Openings, Including Epdm Rubber/Neoprene Gasket And All Necessary Accessories, Complete In All Respects As Per The Directions Of The Engineer-In-Charge. , Electrical Work , Laying And Fixing Of One No Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq.Mm (Clamped With 1Mm Thick Saddle) Size On Wall Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 4 X 16 Sq. Mm (25Mm) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Supplying And Fixing Of 4 Way (4 + 12), Double Door Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs As Required . , Supplying And Fixing 6 Way, Double Door, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator. , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole And Neutral , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole , Supplying & Fixing 5A To 32 A Rating, 240/415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load For Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required.4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 2 Module (75Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 3 Module (100Mmx75mm) , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required 6 Module (200Mmx125mm) , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5/6 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15/16 A Switch , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5/6 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15/16 A Socket Outlet , Supplying And Fixing Following Modular Switch / Socket /Regulator On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Bell Push , 2M Stepped Type Electronic Fan Regulator , Wiring For Light Point/Fan Point/Exhaust Fan Point/Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Group Controlled (Looped) Light Point/ Fanpoint/ Exhaust Fan Point/ Call Bell Point (Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit,And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. (Group-C) , Providing And Fixing 6 Swg Dia G.I Wire On Surface Or In Recess For Loop Earthing As Required. , Supplying, Installation, Testing & Commissioning Of Photo Electronic Smoke Detector With Builtin Led And Mounting Base Plate Suitable With Ms Junction Box For Operation On 12V / 24V Complete With All Connections Etc. As Required. , Supplying, Installation, Testing & Commissioning Of Manual Call Box Of Abs Type In Surface/Recess With Stainless Steel Chain & Hammer Assembly Complete With Glass And Push Button Etc. As Required. , Supplying & Laying Of 2 X 1.5 Sqmm Fire Alarm Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Xlpe Insulation, Steel Wire Armouring & Frls Outer Sheath Complete As Required. , Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With Upto 32A, 240 V, C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 32 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Spmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required , Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85, Air Delivery Minimum 215 Cmm, 350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Speed Control Compitable For Electronic Type Regulator And All Remaining Accessories Including Safety Pin,Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Including Fixing Fan Hook In Ceiling Complete As Required. , Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft.,40W Of Powder Coated Die Cast / Extruded Aluminium Body (Thickness ≥ 1.20 Mm) Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency 85%, Operating Voltage Ac 140 270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection, Thd 10% , P. F.≥0.95, Ip20, Cri 80, Ugr (Unified Glare Rating) 19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With, 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 5700°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required. System Lumen Efficacy ≥105 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. , Supplying And Fixing Of 25Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Drawing 1 Run Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended/Surface Mount From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Installing 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Painted With Powder Coating M.S. Cable Trays Bends With Perforation Not More Than 17.5%,, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. , Supplying And Fixing Call Bell/ Buzzer Suitable For Single Phase, 230 V, Complete As Required. , Supplying And Fixing Fp Mcb Sheet Steel Enclosure With Din Rail On Surface / Recess Etc. As Required. , Supplying & Fixing Of 4Pole, 63 A Rating, 415V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 16Sq.Mm, Aluminium , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,4C X 6Sq.Mm, Copper , Supply Of Following Core, Size And Conductor 1.1Kv Grade Xlpe Insulated, Pvc Sheathed, Armoured Ug Cable In One Length As Per Is : 7098 (Pt-1) 1988,3C X 4 Sq.Mm, Copper , Supply And Laying Of Un Armoured Copper Single Core 10 Sq.Mm Flexible Cable With Annealed Copper Conductor In Suitable Size Hdpe Pipe In Ground/ On Surface As Required. , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Copper Conductor Cable Of 1.1 Kv Grade As Required.3 X 4 Sq.Mm , Supply ,Installation, Testing And Commissioning Of 2 Tr/24000Btu Per Hour And Bee-5 Star Rated Wall Mounted Inverter Type Hi Wall Split Cooling Air Conditioner Having Wireless Remote Controller, Hermetically Sealed/Scroll/Rotary Compressor And Eco Friendly Refrigerant,Initial Charge Of Refrigerant,Condensor And Evaporator Coils Of Copper Material, Air Filter With Auto Swing & Auto Restart Features, Suitable For Operation On 230V, Single Phase, 50Hz, Ac Power Supply. The Indoor Unit Shall Be Fixed Rigidly On Wall Using Necessary Frame, The Outdoor Unit Shall Be Mounted On Wall Or Floor Using Suitable Powder Coated Ms Angle Frame As Required. Including Clamps, Bolts, Nuts,Vibrating Dampers, Laying Of 3 Meter Standard Length Of Copper Refrigerant Piping With 3 Meter Pvc Covering Pipe, 3 Meter Drain Piping, Wrapping Tape And Necessary Insulation ,Electrical Flexible Cable Connectivity Between Indoor And Outdoor Unit. Necessary Drilling Of Hole And Finishing The Same To Match For The Surrounding As Required. , Supplying And Fixing Of Frp Box 200Mmx140mmx95mm Size (Nominal Size) On Surface With Hinged Door With Suitable Grounding Copper Bar Link With Holes Fitted Inside The Box Etc. As Required. , Supplying And Fixing Of Dual Rj 45 / Io Outlet On Existing Modular Switch Plate. , Supply,Installation,Testing And Commissioning Of Maintenace Free Earth Pit Of Single Pipe Technology Copper Pipe Of 2000Mm Long (Min), Outer Dia 50 Mm, Wall Thickness 1.2Mm(Min), Filled With Highly Conducting Metallic Compounds With The Permanent Sealing At Both The Ends And Lead Terminal Of 50 X 10 Mm Size At The Top The Length Of The Electrode Shall Be 2000 Mm Excluding The Lead Terminal And The Length Of The Lead Terminal At The Top Shall Be Minimum 50Mm. To Ensure The Moisture Content And Electrical Conductivity, Resistance Lowering Grounding Minerals Shall Be Filled Around The Electrode Of (Min25 Kg) .Heavy Duty Weather Proof Plastic Earth Pit Chamber With Cover Of Dimension 300 Mm Dia (Top), 260 Mm Dia(Bottom) And 300 Mm (Height) Shall Be Used, Numbering Of Pit And Measured Value Written With Weather Proof Painting Or Stickering. As Required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
2.
Housing Urban and Rular Development #11432190 Price Bid
Tender for 2.6.1Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq M On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. - All Kinds Of Soil , 2.25Filling Available Excavated Earth (Excluding Hard Rock/Ordinary Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , 2.27Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , 4.1.4 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1 :2:4 (1 Cement : 2 Coarse Sand (Zone-Ill) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mmnominal Size) , 4.17Making Plinth Protection 50 Mm Thick Of Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand (Zone-Ill) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75 Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level [ 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii): 3 Graded Stone Aggregate 20 Mm Nominal Size) ] , 5.33.1.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Upto Plinth Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.33.2.1 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana I Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate I Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , 5.22.6Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , 5.9.1Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Foundations, Footings, Bases For Columns , 5.9.5Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.21Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , 6.1.2Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 7.1.1Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1 :6:12 (1 Cement: 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , 8.14.4.1Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1 :2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) :White Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing. 70 Mm Thick , 8.25.1Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 40 Mm Thick , 8.25.4Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , 10.16.1Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , 10.25.1Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , 11.41.2Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , 12.34Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg I M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm)@ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , 12.50Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , 12.51.2 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Flashings/ Aprons.( Upto 600 Mm) , 12.51.6 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Gutter (600 Mm Over All Girth) , 13.50.2Applying Priming Coat: With Ready Mixed Aluminium Primer Of Approved Brand And Manufacture On Resinous Wood And Plywood , 13.50.3Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , 13.62.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , 13.68.1French Spirit Polishing :Two Or More Coats On New Works Including A Coat Of Wood Filler , 16.69 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature, Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Making Joints With Or Without Grooves (Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer In-Charge (Length Of Finished Kerb Edging Shall Be Measured To Calculate Volume For Payment). (Precast cement concrete Kerb Stone Shall Be Approved By Engineer-In-Charge). , 16.92Providing And Fixing 10X10x7.50 Cm Granite Stone Block Hand Cut And Chisel Dressed On Top, For Paving In Floors, Drains Etc. Laid Over 20 Mm Thick Base Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints 10 Mm Wide Filled With Same Mortar Including Ruled Pointing Etc. Complete As Per Direction Of Engineer-In-Charge. , 1-2Excavationinfoundationfor Retaining,Breastwallsetc, Inall Typesofsoils And Rocks Includingall Lead, Lift Anddisposal Of Surplusmaterial Asper Direction Of Engineer- In- Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , 1-4 Randomrubblestonemasonry Laid In1:6Cement Andsandmortar, In Breastwalls,Retainingwalls,Parapets,Scuppers,Etc. Includingsupplyofall Material, Labour, T&Pand Royaltiies Etc. Complete As Per Drawingand Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , 1-3 Randomrubblestonemasonry Laiddry, Inbreastwalls, Retainingwalls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Completeasper Drawingand Technical Specificationsclauses702, 704, 1202 & 1203 Of Mord Specifiction , 1-5 Handpackedstonefillinginbackofwallls Includingcostofallmaterials, Royality,T&Petc.Completeasperdirectionofengineer-In-Charge. (Asper Pwd Uttarakhand Specifications) , 2-2Concretewithcement, Coarsesandand40mmgaugestoneballast In Proportion1:4:8 In Foundationsand Floors Includingsupplyof Allmaterial, Labour Andt&Petc. Required For Proper Completionof Thework. Asper Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , 3-7Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgradereplacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2As Per Technical Specification Clause 302.3.11 , 12-9Providing Weepholes In Brick Masonry/Stone Masonry, Plain/Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Providing & Supplying Of 25W Self Ballasted Led , Providing & Supplying Of Decorative Lighting Pole Of 4M , Providing & Fixing Of Aayush Wellness Based Signages/Boards Including Vertical Pole & Ms Sheet , Providing & Fixing Of Aayush Wellness Based 3D Paintings With Pop Texture Including Texture Paint
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
3.
Housing Urban and Rular Development #11432178 Price Bid
Tender for Excavation In Foundation For Retaining, Breast Walls Etc, In All Types Of Soils And Rocks Including All Lead, Lift And Disposal Of Surplus Material As Per Direction Of Engineer - In - Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , Removal Of Unsuitable Soil With Disposal Upto 1000 M Removal Of Unsuitable Soil Including Excavation, Loading And Disposal Upto 1000 M Lead But Excluding Compaction Ground Supporting Embankment Subgrade Replacement By Suitable Soil, Which Shall Be Paid Separately As Per Clause 303.5.2 As Per Technical Specification Clause 302.3.11 , Concrete With Cement, Coarse Sand And 40 Mm Gauge Stone Ballast In Proportion 1:4:8 In Foundations And Floors Including Supply Of All Material, Labour And T&P Etc. Required Forproper Completion Of The Work. As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 , Random Rubble Stone Masonry Laid In 1:6 Cement And Sand Mortar, In Breast Walls, Retaining Walls, Parapets, Scuppers, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , Random Rubble Stone Masonry Laid Dry, In Breast Walls, Retaining Walls, Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1203 Of Mord Specifiction , Hand Packed Stone Filling In Back Of Wallls Including Cost Of All Materials, Royality, T&P Etc. Complete As Per Direction Of Engineer-In- Charge. (As Per Pwd Uttarakhand Specifications) , Providing Weepholes In Brick Masonry/Stone Masonry, Lain / Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Excavation In Hilly Areas In Ordinary Rock By Mechanical Means Not Requiring Blasting (With Out Dozer) Excavation In Hilly Area In Ordinary Rock Not Requiring Blasting By Mechanical Means Without Using Dozer Including Cutting And Trimming Of Slopes And Disposal Of Cut Material With A Lift Upto 1.5 M And Lead Upto 20 M As Per Clause 1603.2. , Providing And Laying Of Stone Set Pavement Over 2.5 Cm Thick Bedding Layer Of Plain Cement Concrete 1:2:4 Which Shall Further Be Placed Over 10 Cm Thick Dry Stone Kharanja Or Crushed Stones Base Over A Prepared Subgrade As Per Drawings And Technical Specifications. The Size Of Stones Shall Not Be Less Than 20Cm X 20Cm And Thickness Of Stones Shall Vary From 10Cm To 15 Cm. The Work Includes Filling Of Joints With Plain Cement Concrete 1:2:4 As Per The Standard Drawings And Instructions Of The Engineer-In-Charge. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, For All Lift, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : - 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 (1 Cement: 6 Fine Sand) - Outer Plaster , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : 13.41.1 New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Seamless Type Tubes , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggreentrance Gate 20 Mm Nominal Size Derived From Natural Sources) , Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggreentrance Gate 20 Mm Nominal Size) Upto Plinth Level With : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggreentrance Gate 20 Mm Nominal Size Derived From Natural Sources) , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Water Proof Ply 12 Mm Thick , Random Rubble Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like. Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Pointing On Stone Work With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) : Raised And Cut Pointing , Providing And Fixing 2Nd Class Teak Wood Plain Lining Tongued And Grooved, Including Wooden Plugs Complete With Necessary Screws And Priming Coat On Unexposed Surface. 12 Mm Thick , French Spirit Polishing : Two Or More Coats On New Works Including A Coat Of Wood Filler , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg / M3, 50Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Flashings/ Aprons.( Upto 600 Mm) , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Gutter (600 Mm Over All Girth) , Manufacturing, Supplying And Fixing Retro Reflective Sign Boards Made Up Of 2 Mm Thick Aluminium Sheet, Face To Be Fully Covered With High Intensity Encapsulated Type Heat Activated Retro Reflective Sheeting Conforming To Type - Iv Of Astm-D 4956-01 In Blue And Silver White Or Other Colour Combination Including Subject Matter, Message (Bi-Lingual), Symbols And Borders Etc. As Per Irc ; 67:2001, Pasted On Substrate By An Adhesive Backing Which Shall Be Activated By Applying Heat And Pressure Conforming To Class -2 Of Astm-D-4956-01 And Fixing The Same With Suitable Sized Aluminium Alloy Rivets @ 20 Cm C/C To Back Support Frame Of M.S. Angle Iron Of Size 25X25x3 Mm Along With Theft Resistant Measures, Mounted And Fixed With 2 Nos. M.S. Angles Of Size 35X35x5 Mm To A Vertical Post Made Up To M.S. Tee Section Ismt 50X50x6 Mm Welded With Base Plate Of Size 100X100x5 Mm At The Bottom End And Including Making Holes In Pipes, Angles Flats, Providing & Fixing M.S. Message Plate Of Required Size, Steel Work To Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade And Of Approved Brand & Manufacture Over Priming Coat Of Zinc Chromate Yellow Primer (Vertical Ms-Tee Support To Be Painted In Black And White Colours).Backside Of Aluminium Sheet To Be Painted With Two Or More Coats Of Epoxy Paint Over And Including Appropriate Priming Coat Including All Leads And Lifts Etc. Complete As Per Drawing, Specification And Direction Of Engineer-In-Charge. 16.59.1 Mandatory/ Regulatory Sign Boards Of 900 Mm Diametre With Support Length Of 3750 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone - Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth , Providing And Fixing Plain Lining With Necessary Screws/Nuts & Bolts/ Nails, Including A Coat Of Approved Primer On One Face, And Fixed On Wooden /Steel Frame Work, Complete As Per Direction Of Engineer-In- Charge (Frame Work Shall Be Paid For Separately). 12 Mm Thick Commercial Ply Conforming To Is : 1328 Bwr Type , Providing Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Fibre Glass Wool Conforming To Is : 8183, Density 24Kg / M3, 50Mm Thick, Wrapped In 200 G Virgin Polythene Bags, Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Of External Wall System On Light Gauge Steel Frame Work With Outer Face Cement Boards As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60 Cm C/C Of Approved Make. A Groove Of 2 Mm To 3 Mm Shall Be Maintained And Grooves Shall Be Sealed With Silicon Based Sealant. The Board Shall Be Fixed In A Staggered Pattern. Screws Shall Be Of Counter Sunk Rib Head Of 1.60 Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm And. Internal Face 12.5 Mm Thick Gypsum Plaster Board Fixed On Cement Board As Per Standard Sizes Fixed With Self- Drilling / Taping Screws / Fasteners @ 60Cm C/C Of Approved Make, Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish.(Cost Of Frame Work To Be Paid For Separately) Outer Face- Outer Face Having 6 Mm Thick Fiber Cement Board Type A, Category-Iv As Per Is:14862:2000 Fixed On 9 Mm Thick Fiber Cement Board, Type A, Category-Iv As Per Is:14862:2000 (High Pressure Steam Cured) Inner Face- 12.5 Mm Thick Gypsum Plaster Board Conforming To Is 2095:2011 Fixed On 8 Mm Thick Fibre Cement Board Of Type B, Category-Iii As Per Is:14862:2000 (High Pressure Steam Cured) , Providing And Fixing Internal Wall Panels On Light Gauge Steel Frame Work With 12.5 Mm Thick Gypsum Plaster Board Conforming Is 2095:2011 Fixed On Cement Board As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60 Cm C/C Of Approved Make, Screws Shall Be Of Counter Sunk Rib Head Of 1.60 Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm. Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish.(Cost Of Frame Work To Be Paid For Separately Cement Fiber Board 8 Mm Thick Of Type B, Category Iii As Per Is 14862:2000 (High Pressure Steam Cured) , Providing And Fixing In All Exterior Face Panels Breathable Vapour Barrier Underneath The Cement Fiber Board As Per National Building Code 2009 Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing M.S. Tubular Frames For Doors, Windows, Ventilators And Cupboard With Rectangular/ L-Type Sections, Made Of 1.60 Mm Thick M.S. Sheet, Joints Mitred, Welded And Grinded Finish, With Profiles Of Required Size, Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 10.15.1 Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size , Providing And Fixing Pressed Steel Door Frames Conforming To Is: 4351, Manufactured From Commercial Mild Steel Sheet Of 1.60 Mm Thickness, Including Hinges, Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25 Mm, Or Base Ties Of 1.60 Mm, Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Including M.S. Pressed Butt Hinges 2.5 Mm Thick With Mortar Guards, Lock Strikeplate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface As Directed By Engineer In-Charge: Profile B Fixing With Carbon Steel Galvanised Dash Fastener Of Required Dia And Size (To Be Paid For Separately) , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding , Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With 12 Mm Mild Steel U Beading (Mosquito Jali). , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows, All Complete With : 10.30.1 4.0 Mm Thick Glass Panes , Providing And Fixing Isi Marked Oxidised M.S. Handles Conforming To Is:4992 With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 125 Mm , Providing And Fixing Isi Marked Oxidised M.S. Tower Bolt Black Finish, (Barrel Type) With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 250X10 Mm , Providing And Fixing Isi Marked Oxidised M.S. Sliding Door Bolts With Nuts And Screws Etc. Complete (Copper Oxidised As Per Is 1378) - 300X16 Mm , Providing And Fixing Isi Marked 85X42 Mm Oxidised M.S. Pull Bolt Lock Conforming To Is : 7534 With Necessary Screws Bolts, Nut And Washers Etc. Complete (Copper Oxidised As Per Is 1378). , Providing And Fixing Aluminium Hanging Floor Door Stopper Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc. Complete. Single Rubber Stopper , Providing And Fixing Ptmt Door Catcher Of Length 72 Mm And Dia. Of 42 Mm With Suitable Washers Weighing Not Less Than 33 Gms , Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately). Size Of Tile 600X600 Mm , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Excavating, Supplying, Stacking And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Foundation Trenches, Plinth, Sides Of Foundation Etc. Complete For All Lift. , Supplying And Filling Of Earth By Mechanical Transport Including Loading, Unloading & Stacking Beyond 5Km Upto 10Km & Beyond 10Km Upto 20Km (Including All) , Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. All Works Above Plinth Level Upto Floor V Level. Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg /Cum , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Extra For Providing And Placing In Position 2 Nos 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry , 12 Mm Cement Plaster Of Mix: 1:6 (1 Cement: 6 Fine Sand) - Inner Plaster , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters: 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screw , Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators, Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Including Riming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings, Complete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment). 10.11.1 Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of cement concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sq.M Including Pointing The Joints With White Cement And Matching Pigments Etc., Complete. , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sq M Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sq M) , Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : (A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. (B) Second Layer Of Slurry Of Cement @ 0.242 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttarakhand View Result →
4.
Power #11419246 AOC
Tender for (A) Supply Part-11/.4 Kv 400 Kva Distribution Sub Station , 11/.4 Kv 400Kva Dtr (Rec Sep. Ord 11/1976 , providing St Pole Pole 9 Mtr. Long W/L 220Kgs , Muff For Steel Tubular Pole With Concrete Filling , X-Arm: [Channel Iron (100X50x5 Mm), Length : 2800 Mm X 2 Nos] For Incomer Line , Ms A.I.(50X50x6 Mm), Length: 2800 Mm X(1 Nos For Las ) , X-Arm: [Channel Iron (75X40x5 Mm), Length : 2800 Mm X 4 Nos] For Supporting Do Fuse Unit & Go Switch , X-Arm: [Channel Iron (100X50x6 Mm), Length : 2800 Mm X 2 Nos] For Transformer Bed , X-Arm [Channel Iron (100X50x6 Mm), Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer] , Ms A.I.(50X50x6 Mm), Length: (2800 Mm) X 2 No. , Ms Angle Iron (35X35x5 Mm), Length : 460 Mm X 2 Nos , Ms A.I.(50X50x6 Mm), Length: (950 Mm) X 2 Nos. Of Bed Knee Bracing , Ms Angle Iron (50X50x6 Mm), Length : (2800 Mm) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.I. Wire For Earthing , Ms Angle Iron (50X50x6 Mm), Length : (450 Mm)X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O. Switch Handle Supporting: [C.I. (75X40x6mm), Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O Ab Switch Unit (11Kv,400,663Ka) Tripple Pole O/D Type , D.O Fuse Unit , Surge Arrester, 9 Kv Station Class , Discs Insulator Sets (Comp. 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) I/C Dead End Clamps Etc.) , Stay Set Complete , Stay Wire (7/3.15Mm)( 10 Kg Per Stay Set) , Pipe Earthing With Gi,Charcoal & Salt , providing Lt Distribution Panel With Acb (630 A, 50 Ka, 4P,1 No.) & Sfu (100 A 6 No. Rewireble) For 400Kva Trf. As Per Specification , Half Clamp (M.S. Flat 50X6) , Full Clamps (M.S. Flat 50X6) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Aluminium Thimbles 300 Mm Sq. , Copper Thimble 95 Mm Sq. , Danger Plate , Barbed Wire (Rec Sp F 3/1981) , Lt Cable 3-1/2 Core-400 Mm Sq.For Incomer , Lt Cable 3-1/2 Core-185Mm Sq.X6 O/G , Alluminium Paint , Prov.Acsr, 6/1/3.35 Mm , Chain Link Fencing , Angle Iron, Gate Etc. For Transfromer Fencing , providing Transformer Bed Plinth For 1X400kva S/Stn Structure Complete With cement concrete 1:6:12 R.R. Massonery & Plastering Etc. A/W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. , Lt Switched Capacitors 50 Kvar For 400 Kva T/F , Hp Monochrome Laser Printer (A4) Hp Laser 108A With Prints Up To 20 Ppm, 64 Mb Ram 600X600 Dpi Print Resolution 150 Sheets Paper Tray Caapcity Usb 2.0 Port -One Year Warranty , (A) Erection Part-11/.4 Kv 400 Kva Distribution Sub Station , 11/.4 Kv 400Kva Dtr (Rec Sep. Ord 11/1976 , providing St Pole Pole 9 Mtr. Long W/L 220Kgs , Muff For Steel Tubular Pole With Concrete Filling , X-Arm: [Channel Iron (100X50x5 Mm), Length : 2800 Mm X 2 Nos] For Incomer Line , Ms A.I.(50X50x6 Mm), Length: 2800 Mm X(1 Nos For Las ) , X-Arm: [Channel Iron (75X40x5 Mm), Length : 2800 Mm X 4 Nos] For Supporting Do Fuse Unit & Go Switch , X-Arm: [Channel Iron (100X50x6 Mm), Length : 2800 Mm X 2 Nos] For Transformer Bed , X-Arm [Channel Iron (100X50x6 Mm), Length : 460 Mm X 2 Nos For Supporting Main Channel Of Transformer] , Ms A.I.(50X50x6 Mm), Length: (2800 Mm) X 2 No. , Ms Angle Iron (35X35x5 Mm), Length : 460 Mm X 2 Nos , Ms A.I.(50X50x6 Mm), Length: (950 Mm) X 2 Nos. Of Bed Knee Bracing , Ms Angle Iron (50X50x6 Mm), Length : (2800 Mm) X2 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.I. Wire For Earthing , Ms Angle Iron (50X50x6 Mm), Length : (450 Mm)X1 Nos For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O. Switch Handle Supporting: [C.I. (75X40x6mm), Length: 460Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly , G.O Ab Switch Unit (11Kv,400,663Ka) Tripple Pole O/D Type , D.O Fuse Unit , Surge Arrester, 9 Kv Station Class , Discs Insulator Sets (Comp. 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) I/C Dead End Clamps Etc.) , Stay Set Complete , Stay Wire (7/3.15Mm)( 10 Kg Per Stay Set) , Pipe Earthing With Gi,Charcoal & Salt , providing Lt Distribution Panel With Acb (630 A, 50 Ka, 4P,1 No.) & Sfu (100 A 6 No. Rewireble) For 400Kva Trf. As Per Specification , Half Clamp (M.S. Flat 50X6) , Full Clamps (M.S. Flat 50X6) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Aluminium Thimbles 300 Mm Sq. , Copper Thimble 95 Mm Sq. , Danger Plate , Barbed Wire (Rec Sp F 3/1981) , Lt Cable 3-1/2 Core-400 Mm Sq.For Incomer , Lt Cable 3-1/2 Core-185Mm Sq.X6 O/G , Alluminium Paint , Prov.Acsr, 6/1/3.35 Mm , Chain Link Fencing , Angle Iron, Gate Etc. For Transfromer Fencing , providing Transformer Bed Plinth For 1X400kva S/Stn Structure Complete With cement concrete 1:6:12 R.R. Massonery & Plastering Etc. A/W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing. , Lt Switched Capacitors 50 Kvar For 400 Kva T/F , Hp Monochrome Laser Printer (A4) Hp Laser 108A With Prints Up To 20 Ppm, 64 Mb Ram 600X600 Dpi Print Resolution 150 Sheets Paper Tray Caapcity Usb 2.0 Port -One Year Warranty , (B) Supply Part-Ct/Pt Unit 400 Kva Trf. (1 Nos.) , providing 11Kv Ct-Pt Unit Ct/Pt Combined Unit 11 Kv /110V 50/5 A , Prov, Energy Meter (3 Phase, 4 Wire) Ht Ct Type For Above , Pvc Multistrand 2.5 Mm Sq. Copper Wire , 1 Inch Dia Gi Pipe For Concealin , Bend Joints /Elbow , X-Arm: [Channel Iron (75X40x6 Mm), Length : 2800 Mm X 2 Nos] For Supporting Main Channel For Ct-Pt Unit , Ms Angle Iron (50X50x5 Mm), Length : 2800Mmx 4 Nos. , Ms Angle Iron (35X35x5 Mm), Length : 2800Mmx 2 Nos. , Half Clamp (Ms Flat 50X6 Mm) , Full Clamp (Ms Flat 50X6 Mm) , Nut & Bolts Off Size , Aluminium Thimble , Copper Thimble , (B) Erection Part-Ct/Pt Unit 400 Kva Trf. (1 Nos.) , providing 11Kv Ct-Pt Unit Ct/Pt Combined Unit 11 Kv /110V 50/5 A , Prov, Energy Meter (3 Phase, 4 Wire) Ht Ct Type For Above , Pvc Multistrand 2.5 Mm Sq. Copper Wire , 1 Inch Dia Gi Pipe For Concealin , Bend Joints /Elbow , X-Arm: [Channel Iron (75X40x6 Mm), Length : 2800 Mm X 2 Nos] For Supporting Main Channel For Ct-Pt Unit , Ms Angle Iron (50X50x5 Mm), Length : 2800Mmx 4 Nos. , Ms Angle Iron (35X35x5 Mm), Length : 2800Mmx 2 Nos. , Half Clamp (Ms Flat 50X6 Mm) , Full Clamp (Ms Flat 50X6 Mm) , Nut & Bolts Off Size , Aluminium Thimble , Copper Thimble , (C) Supply Part-New Ht Line (2.43 Kms. With Acsr 6/1/3.35 Mm Sq. On Steel Poles , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 11 Mtr. Long W/L 227 Kgs/M2 (With Ruling Span 90M, 8 No. Run Through And 3 No. Double Pole Dead End Structure , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole (2000Mm Long) With Concrete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length 1270 Mm (I/C Tolerence Of 100Mm Either Side) X2 Structure( Run Through Structure (Formation Tringle) , Angle Iron (50X50x5 Mm), Length (2X750) Mm X 1 Structures (Run Through Structure (Formation Tringle) , Pole Top Bracket [Msci:100X50x6mm-100Mm] , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure (Run Through Structure (Formation Tringle) , Belt Set - Ms Angle Iron: 50X50x6, Length [1800 Mm X 2 No.]For Dead End Structures , X-Bracing Set - Ms Angle Iron: 50X50x6, Length [2125 Mm X2 No.] For Dead End Structures , X-Arm(Horizental) - Ms C. Iron: 50X50x6, Length [2340 Mm X2 No.]For Dead End Structures , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides)For Dead End Structures , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure For Dead End Structures , Stay Set Complete In All Respect I/C Clamp ( Single Pole-1No. , /D. Pole Structures-4Nos.) , Stay Wire (7/3.15 Mm) (9.0 Kg Per Stay Set) , G.I. Wire , Eye Hook For Earth Wire , Earth Wire Clamp , Ht Earthing Set Complete (Rec construction Standared J-1) , Half Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Full Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Danger Plate (250X200x1.6 Mm) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Barbed Wire (Rec Sp F 3/1981) , G.O Ab Switch Unit (11Kv,630 A,25Ka) , D.O Fuse Unit , M.S. C.I. 2400 Mm For Road Crossing (75X40x6mm) , Alluminium Paint , (C) Erection Part-New Ht Line (2.43 Kms. With Acsr 6/1/3.35 Mm Sq. On Steel Poles , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 11 Mtr. Long W/L 227 Kgs/M2 (With Ruling Span 90M, 8 No. Run Through And 3 No. Double Pole Dead End Structure , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole (2000Mm Long) With Concrete Filling , Cross Arm: [Channel Iron (100X50x6 Mm), Length 1270 Mm (I/C Tolerence Of 100Mm Either Side) X2 Structure( Run Through Structure (Formation Tringle) , Angle Iron (50X50x5 Mm), Length (2X750) Mm X 1 Structures (Run Through Structure (Formation Tringle) , Pole Top Bracket [Msci:100X50x6mm-100Mm] , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure (Run Through Structure (Formation Tringle) , Belt Set - Ms Angle Iron: 50X50x6, Length [1800 Mm X 2 No.]For Dead End Structures , X-Bracing Set - Ms Angle Iron: 50X50x6, Length [2125 Mm X2 No.] For Dead End Structures , X-Arm(Horizental) - Ms C. Iron: 50X50x6, Length [2340 Mm X2 No.]For Dead End Structures , Discs Insulator Sets On Dead End Structures (Comprising 1 No. Disc: ^^(Porcelain, Bs, 12 Kv, 90 Kn) Including Dead End Clamps Etc.) X (3 No. Conductors) X (2 No. Sides)For Dead End Structures , 11 Kv Pin Insulators (Porcelain, 12 Kv, 10 Kn): 3 No Per Pole Structure For Dead End Structures , Stay Set Complete In All Respect I/C Clamp ( Single Pole-1No. , /D. Pole Structures-4Nos.) , Stay Wire (7/3.15 Mm) (9.0 Kg Per Stay Set) , G.I. Wire , Eye Hook For Earth Wire , Earth Wire Clamp , Ht Earthing Set Complete (Rec construction Standared J-1) , Half Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Full Clamp (On D/P Dead End Str:2Nos. On T/P Dead End String 1 Nos ; On Run Through Strengthening 3Nos.) , Danger Plate (250X200x1.6 Mm) , M. S. Nuts & Bolts Off Sizes (Galvanised Coated) [Prefarably 16Mm Ø Or More (With Flat And Spring Washer) , Barbed Wire (Rec Sp F 3/1981) , G.O Ab Switch Unit (11Kv,630 A,25Ka) , D.O Fuse Unit , M.S. C.I. 2400 Mm For Road Crossing (75X40x6mm) , Alluminium Paint , (D) Supply Part-Three Phase Lt Line With Aaac 6/1/3.35 Mm Sq. On Steel Poles(0.830 Km) 3-Phase 4 Wire Double Circuit Line , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole , Shackle Insulators (16Kn) (Recd-3/761)(Iss No 1445/1977) , D-Iron (U-Clamp) (Recd-4/79)(Iss No 7935/1975) , Lt Saty Set Complete Rec No 31/1983 , Stay Wire (7/3.15 Mm) (8.0 Kg Per Stay Set) , providing Full Clamp , Earthing Set , G.I.Wire No 8 Swg Earth Wire 1.03Km (Sep.G-2/72) For Suporting Cable , M.S.Nuts & Bolt Off Sizes , C.I. 75X40x6mm (Length 2400X2 Mm) For Centilever Double Circuit Line , Aluminium Paint , (D) Erection Part-Three Phase Lt Line With Aaac 6/1/3.35 Mm Sq. On Steel Poles(0.830 Km) 3-Phase 4 Wire Double Circuit Line , Acsr 6/1/3.35 (Rabbit) {Includes 3 Conductor Lengths For 3Φ And Additional 1% (Sag, Jumpering And Wastage} , providing St Pole Pole 9 Mtr. Long W/L 200 Kgs , Muff For Steel Tubular Pole , Shackle Insulators (16Kn) (Recd-3/761)(Iss No 1445/1977) , D-Iron (U-Clamp) (Recd-4/79)(Iss No 7935/1975) , Lt Saty Set Complete Rec No 31/1983 , Stay Wire (7/3.15 Mm) (8.0 Kg Per Stay Set) , providing Full Clamp , Earthing Set , G.I.Wire No 8 Swg Earth Wire 1.03Km (Sep.G-2/72) For Suporting Cable , M.S.Nuts & Bolt Off Sizes , C.I. 75X40x6mm (Length 2400X2 Mm) For Centilever Double Circuit Line , Aluminium Paint
Contract Date: Jun 30, 2026 Contract Value : 37.28 Lakh
Government Departments No of Bidders 7
Himachal Pradesh View Result →
5.
Public Administrative Department #11418998 AOC
Tender For General-Aroor Gp 2024-25 Pro.No-145/25-Additional Construction In Mcf-General Civil Work - Constraction for machine Room 2 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 3 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 4 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 5 OD304174/2024-2025:Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site 6 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 7 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 8 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 9 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 10 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars 11 50.2.25.1:Filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge 12 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 13 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 14 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 15 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm) 16 16.71:Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer - in- Charge. 17 50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete 18 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 19 13.3.2:20 mm cement plaster of mix:1:6 ( 1 cement : 6 fine sand) 20 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 21 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 22 10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 23 10.7:Providing and fixing ball bearing for rolling shutters. 24 10.8.1:Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area 25 4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 26 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 27 51.2.3:Filling with Quarry Muck
Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade 28 16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 29 16.68:Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 30 50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete 31 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 32 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
Contract Date: Jun 30, 2026 Contract Value : 21.18 Lakh
Government Departments No of Bidders 2
6.
Public Administrative Department #11417772 Price Bid
Tender For Repairing And Maintenance Of Civil Related Works In Ward No.19 (For The Year 2025-26)-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge. Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means Removing and Transporting of excavated / demolished material within PCMC limit including loading, unloading, stacking the material as directed by Engineer-in-charge etc. complete. (For Lead 10.0 Km). Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with WITHOUT SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer Page No - 3 without SCADA with fine agreegates of required specifications (Crushed sand / VSI grade ) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material Granular Sub Base Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material (Note- As per circular issued by Hon. city engineer PCMC , vide civil/CE/TS/23/16/2023.Date 21/04/2023 .Rate is reducedby 20% as material is brought from PCMCs C and D waste processing plant.) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Construction of granular Page No - 4 sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Note- As per circular issued by Hon. City Engineer, PCMC vide circular no.Civil/CE/TS/23/16/2023 Dated 21/04/2023, rate is reduced to 20% as material is to be brought from C and D work processing plant Supplying hard murum/ kankar at the road site, including conveying and stacking complete. Spreading hard murum/ soft murrum/ gravel or kankar for side width complete Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel st anchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. PARDI of required thickness including centering, formwork, cover blocks, laying/pumping ,compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural Page No - 6 steel). with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With Crushed sand VSI Grade. Spec. no.:- Bd.F.11 Page No. 304 and B.7, Page No. 38 Ground Floor Providing fly ash brick masonry with conventional / S. type fly ash bricks in C.M. 6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints un exposed faces and watering etc.complete. Providing waterproof plaster W.C. and bath 20 mm thick dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. Removing the tar or coba and disposing of the material as directed etc. complete. Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 M Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Maharashtra View Result →
7.
Public Administrative Department #11417771 Price Bid
Providing Civil Works In Ward No.14 Kalbhor Nagar, Moannagar And Other Areas (Year 2025-26)-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for thefoundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete. Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge. Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, f oundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No.: Bd.F.17, Page No. 306 Ground Floor Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means Removing and Transporting of excavated / demolished material within PCMC limit including loading, unloading, stacking the material as directed by Engineer-in-charge etc. complete. (For Lead 10.0 Km). Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with WITHOUT SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (VSI sand finely washed etc ) Providing and laying in situ cement concrete of 1:2:4 proportion with trap/ granite/ quartzite/ gneiss metal in foun dation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer without SCADA with fine agreegates of required specifications (Crushed sand VSI grade ) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material Granular Sub Base Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material (Note- As per circular issued by Hon. city engineer PCMC , vide civil/CE/TS/23/16/2023.Date 21/04/2023 .Rate is reducedby 20% as material brought from PCMCs C and waste processing plant.) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader / Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - II Material Note- As per circular issued by Hon. City Engineer, PCMC vide circular no.Civil/CE/TS/23/16/2023 Dated 21/04/2023, rate is reduced to 20% as material is to be brought from C and D work processing plant Supplying hard murum/ kankar at the road site, including conveying and stacking complete. Spreading hard murum/ soft murrum/ gravel or kankar for side width complete Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/bolted/welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shadeetc. complete. Ground Floor Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel st anchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Lift 0.0 to 3.8 M Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. PARDI of required thickness including centering, formwork, cover blocks, laying/pumping ,compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With Crushed sand VSI Grade. Spec. no.:- Bd.F.11 Page No. 304 and B.7, Page No. 38 Ground Floor Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Lift 0.0 to 3.8 M Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. Removing the tar or coba and disposing of the material as directed etc. complete. Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering to 10 Square Metre Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground Floor Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground Floor Lift 0.0 to 3.8 M Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Providing and applying two coats of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Providing and applying two coats (exterior quality) of flat oil paint of approved colour and shade to the plastered surface in buildings and workshops including scaffolding if necessary, cleaning the surface and preparing surface etc. complete. (excluding primer coat) Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Ground Floor Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. Ground Floor Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/One Running Metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 etc
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
Maharashtra View Result →
8.
Educational and Research Institute #11408306 AOC
Bids Are invited for Providing and fixing 22.8 mm thick panels with bottom metal screen, intermediate fabric screens, and top screen in fabric magnetic finish, complete in all respects. Providing and placing NOVA make or equivalent free-standing pedestal with flat metal front of size 390 mm (W) × 435 mm (D) × 646 mm (H), comprising one drawer (1 box + 1 file) with central locking system, complete with all fittings and accessories. Providing and fixing Keyboard Platform Tray (KBPT) with integrated mouse tray, suitable for the workstation, complete in all respects. The complete workstation system shall be Greenguard (UL) certified and BIFMA LEVEL 2 certified. The manufacturer shall possess valid certifications of ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA, as applicable.The work includes transportation, loading, unloading, fixing, alignment, leveling, testing and commissioning, complete, as per approved drawings, specifications and directions of the Engineer-in-Charge , Supplying and placing in position executive main table with ERU and integrated pedestal of overall size 2350 × 2350 × 750 mm (H), comprising primary and secondary work surfaces made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998, finished with 0.4 mm thick PVC membrane pressed on top, complete with soft-closing access flap and in-built power box for cable management. The modesty panel shall be of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998, finished with 0.4 mm thick PVC membrane pressed on top.The under-structure and integrated pedestal shall be made of 25 mm thick pre-laminated twin board of E1-P2 grade, conforming to IS:12823-1990, of approved shade, with all exposed edges edge-banded with matching 2 mm thick PVC lipping. The pedestal shall be of BOX-BOX-FILE configuration, having powder-coated metal panel drawer slides of 400 mm length with 325 mm drawer extension, provided with soft-closing and anti-slam mechanism, suitable handles, and central locking system, complete in all respects. The product shall be GREENGUARD (UL) certified, Indoor Advantage GOLD and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications. The item includes transportation, loading, unloading, fixing, alignment and making functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position back unit of overall size 2350 × 500 × 1800 mm (H), complete in all respects, having top panel made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823-1990, with all exposed edges edge-banded with matching 2 mm thick PVC lipping, sliding door storage unit with body panels including sides, bottom, back and shelves made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick matching PVC edge banding, shutters made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, provided with soft-closing and anti-slam mechanism, suitable handles and locking arrangement, display/storage unit made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick PVC lipping for sides, back and shelves, doors made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, and top panel of display unit also made of 25 mm thick MDF finished similarly, the complete unit being GREENGUARD (UL), Indoor Advantage GOLD and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position high back executive chair, complete in all respects, having cushioned seat made of injection-moulded plastic outer and inner, inner upholstered in pure leather with moulded High Resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf at 25% compression, cushioned back made of PU foam with in-situ moulded M.S. E.R.W. round tube of size 1.9 ± 0.03 cm dia × 0.16 ± 0.0128 cm thick, upholstered in pure leather, seat size 47.6 cm (W) × 49.2 cm (D) and back size 47.5 cm (W) × 77.0 cm (H), PU moulded armrest tops upholstered in pure leather mounted on drop-lift adjustable M.S. E.R.W tubular arm supports of size 3.81 ± 0.03 cm × 0.2 ± 0.01 cm thick with chrome-plated finish, height adjustable up to 6.5 ± 0.5 cm in five steps, provided with active bio-synchro mechanism having 360° revolving, front-pivot tilt with continuous lumbar support, tilt tension adjustment operable in seating position, five-position tilt limiter and seat/back tilting ratio of 1:2, mechanism housing made of HPDC aluminium black powder-coated, provided with seat depth adjustment through integrated sliding mechanism with adjustment range of 6.0 ± 0.5 cm, adjustable back support through up/down mechanism housed in plastic T-spine with adjustment range of 7.42 ± 0.5 cm, pneumatic height adjustment with stroke of 10.0 ± 0.3 cm, pedestal made of high-pressure die-cast polished aluminium fitted with five twin-wheel castors of injection-moulded black polypropylene, pedestal pitch-centre dia 65.0 ± 0.5 cm (75.0 ± 1.0 cm with castors), overall seat height 44.5 to 54.5 cm, overall height 114.0 to 131.5 cm and overall width and depth 76.1 cm each, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position visitor chair, complete in all respects, having cushioned seat made of injection-moulded plastic outer and inner, inner upholstered in pure leather with moulded High Resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf at 25% compression, cushioned back made of PU foam with in-situ moulded M.S. E.R.W. round tube of size 1.9 ± 0.03 cm dia × 0.16 ± 0.0128 cm thick, upholstered in pure leather, seat size 47.6 cm (W) × 49.2 cm (D) and back size 46.5 cm (W) × 59.5 cm (H), provided with cantilever type tubular frame made of SS-202 tube of size Ø 2.54 ± 0.03 cm × 0.02 ± 0.016 cm thick, back connected to frame through chrome-plated high-pressure die-cast connector, overall seat height 46.2 cm, overall height 98.2 cm, overall width 60.9 cm and depth 64.7 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Supplying and placing in position main table of overall size 1800 × 900 × 750 mm (H), complete in all respects, having work surface made of a combination of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, and 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823-1990, with all exposed edges edge-banded with matching 2 mm thick PVC lipping, provided with soft-closing access flap and in-built power box on work surface for wire management, modesty panel made of 25 mm thick MDF, one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, under-structure made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick matching PVC lipping, integrated pedestal made of 25 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823-1990 with 2 mm thick PVC edge banding, drawer fronts made of 25 mm thick MDF one side pre-laminated board conforming to IS:14587-1998 finished with 0.4 mm thick PVC membrane pressed on top, pedestal of BOX-BOX-FILE configuration using powder-coated metal panel drawer slides of 400 mm length with 325 mm drawer extension, provided with soft-closing and anti-slam mechanism, suitable handles and locking arrangement for security, the product being GREENGUARD (UL) certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position mid back chair, complete in all respects, having seat made of 1.5 ± 0.1 cm thick hot-pressed plywood upholstered with fabric upholstery covers and moulded polyurethane foam, with extra thick foam at the front edge for comfort to the popliteal area, back made of injection-moulded glass-filled polypropylene upholstered with mesh fabric and provided with adjustable lumbar support made of injection-moulded polypropylene with adjustment range of 5.0 ± 0.1 cm, seat size 53.5 cm (W) × 51.0 cm (D) and mesh back size 51.0 cm (W) × 70.0 cm (H), seat foam of High Resilience (HR) polyurethane moulded with density 45 ± 2 kg/m³ and hardness 16 ± 2 kgf as per IS:7888 at 25% compression, provided with adjustable armrests having up-down adjustment in six steps (7.2 ± 0.5 cm range) with armrest top PU-moulded over glass-filled nylon insert and mounted on armrest structure made of glass-filled nylon, provided with centre tilt synchro mechanism with multi-lock having 360° revolving, three-position locking with anti-shock mechanism and tilt tension adjustment, pneumatic height adjustment with stroke of 9.5 ± 0.3 cm, pedestal assembly made of injection-moulded glass-filled nylon fitted with five twin-wheel castors, pedestal pitch-centre diameter 66.1 ± 0.5 cm (76.1 ± 1.0 cm with castors), twin-wheel castors injection-moulded in black nylon, overall width 76.1 cm, depth 76.1 cm, height 101.5 to 111.0 cm and seat height 44.5 to 54.0 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position visitor chair, complete in all respects, having single shell seat and back made of 1.2 ± 0.1 cm thick hot-pressed plywood, upholstered with moulded polyurethane foam on top and backing foam on rear side, finished with knitted fabric or leatherette upholstery, with extra thick foam at the front edge for comfort to the popliteal area, High Resilience (HR) polyurethane foam for seat and back moulded with density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf as per IS:7888 at 25% compression, provided with cantilever type visitor tubular frame made of M.S. E.R.W. tube of size Ø 2.54 ± 0.03 cm × 0.2 ± 0.016 cm thickness, powder coated finish of DFT 40–60 micron, armrest tops moulded from polyurethane (PU) with metal insert and mounted on tubular frame, overall width 60.5 cm, depth 65.0 cm, height 86.5 cm and seat height 46.0 cm, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position ergonomic task chair, complete in all respects, having cushioned seat assembly with seat base moulded in glass-filled poly-amide, moulded polyurethane foam upholstered with high-stretch knitted polyester fabric, back injection-moulded in glass-filled polypropylene upholstered with mesh fabric and provided with adjustable lumbar support made of injection-moulded polypropylene with adjustment range of 3.0 ± 0.1 cm, mesh back size 45.5 cm (W) × 54.0 cm (H) and seat size 48.5 cm (W) × 49.0 cm (D), High Resilience (HR) polyurethane foam used in seat and back cushions moulded with minimum density 48 kg/m³ and hardness load 15 ± 2 kgf as per IS:7888 at 25% compression, seat and back firmly connected to base frame and cantilevered to allow multi-dimensional movement with impact cushioning and synchronized seat-back motion during posture changes, back-spine structure comprising “S” shaped spines and spine connector moulded in high-strength glass-filled poly-amide, provided with variable tilt angle recline adjustable through three-position tilt limit feature inbuilt in seat base with user-weight dependent return force, armrest assembly consisting of armrest housing sliding over armrest structure both moulded in glass-filled poly-amide, with button-operated height adjustment of 6.6 ± 0.5 cm, armrest top of integral skin PU moulded over plastic inner moulded in glass-filled poly-amide, pneumatic gas-lift height adjustment with stroke of 9.2 ± 0.3 cm, pedestal made of injection-moulded glass-filled poly-amide having pitch-centre diameter 66.0 ± 0.5 cm (76.0 ± 1.0 cm with castors), fitted with five twin-wheel castors injection-moulded in poly-amide of 5.0 ± 0.1 cm wheel diameter, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position high back chair, complete in all respects, having cushioned seat assembly with seat base moulded in glass-filled poly-amide, moulded polyurethane foam upholstered with high-stretch knitted polyester fabric, cushioned back assembly with back inner moulded in polypropylene, in-situ moulded with polyurethane foam and upholstered with high-stretch knitted polyester fabric, seat size 48.5 cm (W) × 47.0 cm (D) and back size 45.5 cm (W) × 53.0 cm (H), High Resilience (HR) polyurethane foam used in seat and back cushions moulded with minimum density 48 kg/m³ and hardness load 15 ± 2 kgf as per IS:7888 at 25% compression, seat and back firmly connected to base frame and cantilevered to provide multi-dimensional movement, impact cushioning while sitting and synchronized seat-back movement during posture changes, back-spine structure comprising “S” shaped spines and spine connector moulded in high-strength glass-filled poly-amide, provided with variable tilt angle recline adjustable through three-position tilt limit feature inbuilt in seat base with user-weight dependent return force, adjustable armrests comprising armrest housing sliding over armrest structure both moulded in glass-filled poly-amide with button-operated height adjustment of 6.6 ± 0.5 cm, armrest top of integral skin PU moulded over plastic inner moulded in glass-filled poly-amide, pneumatic gas-lift height adjustment with stroke of 9.2 ± 0.3 cm, pedestal assembly made of injection-moulded glass-filled poly-amide having pitch-centre diameter 66.0 ± 0.5 cm (76.0 ± 1.0 cm with castors), fitted with five twin-wheel castors injection-moulded in poly-amide of 5.0 ± 0.1 cm wheel diameter, overall seat height 44.5 to 53.8 cm, overall height 99.5 to 108.8 cm and overall width and depth 76.0 cm each, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading and placing in position, complete as per specifications and directions of the Engineer-in-Charge. , Supplying and placing in position 24-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position 16-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge , Supplying and placing in position 12-seater conference table (MINGLE MODULAR PLT), complete in all respects, having worksurface made of 25 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, with all exposed edges edge-banded with 2 mm thick matching PVC lipping, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, aluminium alloy 63400-WP profiles used for connecting panels together with knock-down construction, provided with plastic ABS access flap for easy access to wires and cables, worktop available in various modular shapes, modesty panel made of 18 mm thick pre-laminated twin board of E1-P2 grade conforming to IS:12823:1990, edge-banded with 2 mm thick matching PVC lipping, powder-coated accent metal strip below work surface made of 0.8 mm CRCA as per IS:513, epoxy polyester powder coated (DFT 40–60 microns), wire management panels made of 0.8 mm CRCA MS IS:513, epoxy polyester powder coated (DFT 40–60 microns), provision to mount Anchor Roma 6 module plate below worktop, and cutouts on top with two-piece injection-moulded plastic component for pulling audio/video cables and connecting devices to power sockets below worktop, the product being GREENGUARD (UL), Indoor Advantage GOLD, GRIHA, SVAGRIHA and GREENPRO certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supply and fixing wooden storage unit of size 1200 × 450 × 1219 mm (H), complete in all respects, comprising low to medium height HDU, with body made of 18 mm pre-laminated board (PLB) with all edges sealed with 0.8 mm thick PVC edgeband, back panel made of 9 mm white pre-laminated board (PLT), complete ready-to-assemble construction using suitable knock-down (KD) fittings, shelves and separator panels (where provided) made of 18 mm white PLT with 0.8 mm edge banding, bottom shelf fixed and other shelves with one-step adjustable positions for optimized storage, door panels made of 18 mm PLB with 2 mm edge banding on all edges, fitted with flush plastic handle vertically at center, doors mounted on suitable hinges with HDU fitted with adjustable height fittings, three-point locking arrangement provided, and all units fitted with 6 mm levelers at the bottom for proper leveling, the product being GREENGUARD (UL) and BIFMA LEVEL-2 certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position one-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 86.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position two-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 172.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position three-seater sofa, complete in all respects, having seat foam made of PU foam with density 28 ± 2 kg/m³ and an additional top layer of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, back foam made of PU foam with density 28 ± 2 kg/m³ and two additional top layers of supersoft PU foam with density 32 ± 2 kg/m³, upholstered in fabric or leatherette, understructure made of 1.2 ± 0.1 cm thick hot-pressed plywood (moisture-resistant and termite-proof as per IS:303) and pinewood cross-sections free from major knots and surface defects, zigzag spring assembly comprising 6 nos. per seat with 3.8 mm dia mounted over understructure for cushioning, leg assembly welded in stainless steel (grade SS 202) tube and plate with plastic end caps, overall dimensions width 206.0 cm, depth 90.5 cm, height 85.5 cm, seat height 45.0 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position three-seater sofa, complete in all respects, overall dimensions width 176.5 cm, depth 81.5 cm, height 83.5 cm, upholstered in PVC material of 1 mm thickness in coffee brown shade, frame made of pine wood with moisture content 10–12%, plywood used in frame 12 mm and 18 mm thick, seat cushion made of slab stock foam with density 32 kg/m³, back and armrest cushions filled with conjugated hollow fiber (recron), webbing made of nylon, legs made of PVC, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing, supplying and placing in position coffee table, complete in all respects, overall size 1202 × 594 × 411 mm (W × D × H), body made of 18 mm pre-laminated particle board (PLB) with all exposed edges edge-banded with 2 mm thick PVC, middle horizontal panel providing storage area, four nylon bushes provided, top comprising 8 mm thick toughened glass glued with UV plate and PLT panel, glass fixed to side vertical panels, PLT top panel hinged to side vertical panels to open upwards, knock-down construction, finish in WENGE shade with suede finish on PLT panels and Sunray finish on UV-glued plates under glass, hardware comprising dowels for knock-down assembly with high-quality standard hardware including screws, door hinges, bumpers, expanding sockets, nylon bushes, etc., including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position coffee table, complete in all respects, overall size 1100 × 600 × 456 mm (L × W × H), table-top made of 8 mm thick toughened clear glass, body made of 18 mm thick pre-laminated board (PLT) in Cincinnati Walnut finish, configuration comprising shelf storage and display space, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position corner table, complete in all respects, overall size 450 × 450 × 606 mm (L × W × H), table-top made of 6 mm thick toughened clear glass, body made of 18 mm thick pre-laminated board (PLT) in Cincinnati Walnut finish, configuration comprising shelf storage and display space, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position corner table, complete in all respects, overall dimensions 60 × 45 × 60 cm (W × H × D), made of 18 mm thick pre-laminated particle board (PLB) with 10 mm thick toughened glass top, construction knock-down type, finish comprising MIP lamination in Black Ink shade with matching matt PVC lipping and digitally printed glass matching the PLB finish, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Supplying and placing in position main table of overall size 1220 × 600 × 750 mm (L × W × H), complete in all respects, work surface made of 25 mm thick pre-laminated board of E1-P2 grade of approved shade conforming to IS:12823:1990, all exposed edges edge-banded with 2 mm thick PVC lipping, access flap provided on work surface for wire management, understructure made of 18 mm thick pre-laminated twin board of E1-P2 grade of approved shade conforming to IS:12823:1990, edge-banded with 2 mm thick PVC lipping, cube legs fabricated from MS ERW tube 50 × 25 × 1.2 mm and 40 × 40 × 1.2 mm as per IS:7138, top of legs welded with 3 mm thick HR steel support brackets (IS:2062) for fixing worktop, welded structure coated with 50 micron epoxy polyester, base fitted with plastic cap with M8 molded insert and straight M8 leveler adjustable up to 50 mm, cross members made from 50 × 25 × 1.2 mm ERW tube (IS:7138), coated with 50 micron epoxy polyester, assembled by friction-fit PDC joinery and grub screws, two cross members per table, power box made of 0.8 mm thick CRCA (IS:513) with 8-module Anchor Roma cutout fixed along the depth of worktop, soft-closing access flap made of aluminum extrusion with PDC parts in aluminum alloy and plastic parts in Nylon 6, wire brush with nylon bristles for cable management, the product being GREENGUARD (UL) certified, with manufacturer holding valid ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. , Providing and placing in position high-back (HB) chair, complete in all respects, with cushioned seat made of injection-molded plastic outer and inner, inner upholstered with leatherette and moulded high resilience (HR) polyurethane foam of density 45 ± 2 kg/m³ and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression; cushioned back made of PU foam with in-situ molded MS ERW round tube 1.9 ± 0.03 cm × 0.16 ± 0.0128 cm, upholstered with leatherette, seat size 47.0 × 48.0 cm (W × D), high-back size 47.7 × 76.4 cm (W × H); armrest top moulded in PU, mounted on drop-lift adjustable tubular support of 3.81 ± 0.03 cm × 0.2 ± 0.01 cm MS ERW tube with chrome finish, height adjustable up to 6.5 ± 0.5 cm in 5 steps; active bio-synchro mechanism with 360° revolving type, front-pivot tilt with feet resting on ground, continuous lumbar support, tilt tension adjustable in seating position, 5-position tilt limiter, seat/back tilting ratio 1:2, mechanism housing of HPDC aluminium black powder coated, seat depth adjustable 6.0 ± 0.5 cm, adjustable back support connected to Up/Down mechanism housed in plastic T-spine adjustable 7.42 ± 0.5 cm, pneumatic height adjustment stroke 10.0 ± 0.3 cm, pedestal of high-pressure die-cast polished aluminium fitted with 5 twin-wheel castors, pedestal pitch-center diameter 65.0 ± 0.5 cm (75.0 ± 1.0 cm with castors), twin-wheel castors injection-moulded black PP, wheel diameter 6.0 ± 0.1 cm, overall chair dimensions: seat height 43.1–53.1 cm, height 112.7–130.2 cm, width & depth 76.1 × 76.1 cm, including transportation, loading, unloading, fixing, alignment and making the unit fully functional, certified Greenguard (UL) and BIFMA LEVEL 2, manufacturer holding ISO 9001, ISO 45001, ISO 50001, IGBC, GRIHA and AIOTA certifications, complete as per approved drawings, specifications and directions of the Engineer-in-Charge. Total Quantity : 172
Contract Date: Ref. Documents Contract Value : 42.59 Lakh
Government Departments No of Bidders 5
9.
Public Administrative Department #11390437 AOC
Providing Wiring And Electrical Items For Anganwadi Schools At Ramannapeta In Division No. 60 In Khammam Municipal Corporation-1. Electrical Wiring Installation Is 732-1989 ( System Voltage Not Exceeding 650 V ) 2. Graphical Symbols Used In Electro-Technology Is 2032-1969 Art-Xi-Electrical Installation Buildings. 3. Fire Safety Of Building ( General ) Electrical Installation Is 1646-1961 4. Pvc Insulated Cables Is 694-1977 5. Pvc Insulated Cables ( Heavy Duty ) Is 1554-1964 6. 5 A Tumbler Switches Is 1087 7. 15A Tumbler Switches Is 2120 8. 3 Pin Plugs And Sockets Is 1293 9. Aluminum Conductors For Insulated Cables Is 1753-1967 10. Recommended Current Ratings For Cables Is 1961-1967 11. Installation And Maintenance Of Paper Insulated Is 1155-1967 Power Cables 12. Earthing Is 3043-1966 13. Rigid Steel Conduits For Electrical Wiring Is 9537-Pii-1989 14. Fittings For Electrical Wiring Is 2667-1964 15. Flexible Steel Conduits Electrical Wiring Is 3430-1966 16. Accessories For Rigid Steel Conduit Insulated Cables Is 3837-1966 17. A C Circuit Breakers Is 2516-1977 18. Heavy Duty Airbreak Switches And Fuses For Is 4047-1967 Voltage Not Exceeding 1000V 19. 11 Kv Xlpe Cables Is 7089-Part-Ii 20. Fuses Is 9224-P-I & Ii 21. Current Transformers Is 2705 22. Voltage Transformers Is 3516 23. Indicating Instruments Is 1248 24. Relays Is Is - 722 25. Integrating Instruments Is Is - 3231 26. Auxillary Contracts Is 2959 27. Auxillary Switches And Push Buttons Is 6875 28. A C Isolators And Earthing Switches Is 1818-1972 29. Central Gear For Voltage Not Exceeding 1000 V Is 4337-1967 30. Installation And Maintenance Of Switchgear Is 3072-1965 31. Enclosed Distribution Fuse Board And Cutouts Is 2675-1964 For Voltage 100 V 32. Airbreak Isolators For Voltage 1000 V Is 2607-1976 33. Marking Alignment Or Switchgear Bushers Main Is 375-1963 Connections And Auxillary Wiring 34. Selection Installation And Maintenance Of Fuses Is 3106-1966 ( Voltages Not Exceeding 650 V ) 35. General And Safety Requirements For Electric Is 1913-1969 Lighting Fittings 36. Lighting Public Thorough Fares Is 1944-1970 37. Waterproof Electric Lighting Fitting Is 3528-1966 38. Water Tight Electric Lighting Fittings Is 3553-1966 39. Luminaries For Street Lighting Is 2149-1970 40. Mild Steel Tubulars And Other Wrought Steel Is 1239-1968 Pipe Fittings 41. Ceiling Fans Is 374-1951 42. Transformers Is 2026-1962 43. Installation And Commissioning Of Transformers Is 1886-1967 44. Protecting Of Buildings And Allied Structures Is 2309-1967 Against Lighting 45. Interior Illumination Is 3636-1966 46. Busbar Ratings Is 8084-1976 47. Onload Change Over Switches Is 4064-1978 48. Alluminium Alloy For Bus Bars Is 5082 49. Factory Built Assemblies Of Switchgear And Is 8623 Control Gear 50. General Requirements Of Switchgear And Control Gear Is 4237 For Voltages Not Exceeding 1000 V. 51. Degree Of Protection Provided By Enclosing For Low Is 2147 Voltage Switchgear
Contract Date: Ref. Documents Contract Value : 1.69 Lakh
Local Bodies No of Bidders 1
10.
Health and Family Welfare #11387303 AOC
Supply Of Furniture To Attached Govt. General Hospital At Asifabad In Komrambheem Asifabad District.-50.00 Attendant Cot With Mattress Scope: This Specification Is For The Requirement Of Iron Cots Suitable For General Purpose In Hospitals. Dimensions: Over All Dimensions Of Cot Of Size Top Frame Shall Be Length 1800 Mm, Width 600 Mm And Height 400 Mm. The Various Tubes Used In Manufacture Of Iron Cots Should Have The Following Outside Diameter And Thickness. Component Outside Dia ( Mm ) Thickness ( Mm ) Four Legs Rectangular 75 X 25 X1.60 Mm Thickness Cross Tubes Cr Tubes 25X25 Mm Sq 1.22Mm Thickness The Ms Flat For Top Shall Be Inside All Four Sides Of Size 50X3 Mm Minimum Thickness Of 3.0 Mm. Material: Frame Work Shall Be Of Cr Sheets Conforming To Is: 513 D Quality. Bows & Rectangle & Square Tubes: These Shall Be Made From Cr Steel Tubes. Shoes: These Shall Be Manufactured From Pvc Shoes. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. Manufacture Manufacture The Bed Frame Shall Be Made From C.R. Sheet Double Bent. It Should Be Reinforced With Two Formed Channels To Size 20 X 50 X 50 X 50 X 20 Mm Of 1.25Mm Thickness Flanges Welded Inside The Length Wise. Overall Sizes Of Mattresses Is ( L ) 1800 Mm X ( W ) 600 Mm X ( H ) 75 Mm Of Pu Foam Of 40 Density, Covered With St Rexine Properly Stitched. Finish As Per General Condition Of Tender 20.00 Alamarah With Acrylic ( Glass ) Door Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding & Co2 Welded. Front Side Doors With Acrylic Transparent Sheet All Round Frame 70 Mm Borders Thickness 5.5 Mm Thickness Dimensions Outer: 1980 H X 910 W X 480 D Mm A. Top, Bottom, Lh & Rh Sides And Back Material Thickness- 1 Mm B. Removable Rh & Lh Main Doors With Stiffeners Material Thickness =1.22 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside Shelve Size Of 908 W X 420 D Of Thickness -1 Mm Cr Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.2 Mm Range As Per Is-513 1994 ( Reaffirmed In 1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 15.00 Table ( Office Table Big Size ) Dimensions:1450 W X 680 D X 750 H ( In Millimetres ) Material: A.Plb / Plt - Top 25 Mm Thickness. All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) Each Plb / Plt May Contain Following Material Layers: Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. D. Storage: 3 Draw & 2 Draw Metal Is Provided For Storage. One Side 2 Draw And Other Side 3 Draw Metal Shall Be Provided. Drawer: • Box-Box-File : Dimensions 390 W X 430 H X 560 D Mm, Construction & Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Think. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 25.00 Chairs For Office 1. Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 ±0.1Cm. Thick Hot-Pressed Plywood Measured And Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. The Chair Is Available In Three Models. Mid Back Size 47.5 Cm. ( W ) X 58.0 Cm. ( H ) *Pch-9U01rg / 9U02rg / 9U12rg Seat Size 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2. High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density = 45±2 Kg / M3 And Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3. Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4. Center Tilt Synchro Mechanism ( For 9U01rg / 9U02rg ) : The Mechanism Is Designed With The Following Features: · 360° Revolving Type. · 3 Position Locking · Tilt Tension Adjustment 5. Tubular Frame ( For 9U12rg ) : The Powder Coated ( Dft 40-60 Microns ) Tubular Frame Is Cantilever Type & Made Of Ø 2.54 ±0.03Cm. X 0.2 ±0.016Cm.Thk. M.S. Er.W. Tube. 6. Pneumatic Height Adjustment ( For 9U01rg / 9U02rg ) : The Pneumatic Height Adjustment Has An Adjustment Stroke Of 12.0 ±0.3Cm. 7. Telescopic Bellow Assembly ( For 9U01rg / 9U02rg ) : The Bellow Is 3-Piece Telescopic Type And Injection Moulded In Black Polypropylene. 8. Pedestal Assembly ( For 9U01rg / 9U02rg ) : The Pedestal Is Injection Moulded In Black 33%Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.3 ±0.5Cm. Pitch-Centre Dia. ( 76.3 ±1.0Cm With Castors ) . 9. Twin Wheel Castors ( For 9U01rg / 9U02rg ) : The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.3 Cm. Depth ( D ) : 76.3 Cm. Height ( H ) : 85.5-97.5 Cm. Seat Height ( Sh ) : 42.5-54.5 Cm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 14.00 Office Chairs S Type With Armrest Seat / Back Assembly: The Seat And Back Are Made From Chemically Treated And Seasoned Wood, Caned And Finished With Teak Melamine Polish And Fitting Is Nuts & Bolts System. Back Size: 38.0Cm ( W ) X 40.0Cm ( H ) . Seat Size: 38.0Cm ( W ) X 42.5Cm ( D ) . Cane For Seat / Back: The Caning Used For Seat / Back Has High Tensile Strength As Per Is:5378 Part Ii, 1990. Cane Breaking Strength = 3000Kg / Mm2 ( Min. ) % Elongation At Break = 25% Armrest Tube ( Enh. Ch-7 ) : The Armrest Tube Is Made Of 0 2.54 ±0.03Cm. X 0.2 ±0.016Cm.Thk. Cr. Tube 25.4 Mm 2 Mm Thickness Armrest ( Enh. Ch-7 ) : The Armrest Is Gas-Assisted Injection Moulded From Black Polypropylene. Understructure Assembly: The Under Structure Assembly Is A Cantilever Type Frame Made Of Dia. 25.4Cm. ( 1” ) X 14 Thick Cr Tube.As Per General Condition. Finish As Per General Condition Of Tender 10.00 Office Chairs S Type Without Armrest Seat / Back Assembly: The Seat And Back Are Made From Chemically Treated And Seasoned Wood, Caned And Finished With Teak Melamine Polish And Fitting Is Nuts & Bolts System. Back Size: 38.0Cm ( W ) X 40.0Cm ( H ) . Seat Size: 38.0Cm ( W ) X 42.5Cm ( D ) . Cane For Seat / Back: The Caning Used For Seat / Back Has High Tensile Strength As Per Is:5378 Part Ii, 1990. Cane Breaking Strength = 3000Kg / Mm2 ( Min. ) % Elongation At Break = 25% Understructure Assembly: The Under Structure Assembly Is A Cantilever Type Frame Made Of Dia. 25.4Cm. ( 1” ) X 14 Thick Cr Tube.As Per General Condition. Finish As Per General Condition Of Tender 5.00 Examination Table Scope: This Specification Is For The Requirement Of Patient Examination Table In Hospitals. The Features To Include All The Requirements As Per Examination Table ( Is: 4787-1968 ) With Additional Provisions For Keeping / Storage Places For Minor Medical Equipment. Table, Examination- Table Used For The Purpose Of Examination Of Patients In The Consulting Rooms, Clinics And Side-Rooms Of Hospital Wards. The Main Dimensions Of Examination Table: 1830 ( L ) X 600 ( W ) X 750 ( H ) Mm Overall Sizes Of Mattresses Is ( L ) 1830 Mm X ( W ) 600 Mm X ( H ) 75 Mm Of Pu Foam Of 40 Density, Covered With St Rexine Properly Stitched. Materials: The Steel Cold Rolled Sheet Used For Top And Head Rest Shall Have A Minimum Thickness Of 1.22 Mm. The Thickness. Cold Rolled Steel Tubes Used And Their Corresponding Outside Diameters For Different Parts Shall Be As Given Below: Part Outside Diameter Of Tube ( Mm ) Thickness Of Tube ( Mm ) Vertical Members 31.75 1.2 Horizontal Members 25.40 1.2 Manufacture A- Framework- The Examination Table Shall Have A Framework Of Single Continuous Lengths Of ---- Steel Tubes. At The Floor End, The Four Upright Members Shall Be Connected Together By Longitudinal And Transverse Two Tie Rods And At The Other End These Shall Support A Formed Sheet Metal Top. For Receiving The Sheet Metal Top, The Top Ends Of The Uprights Shall Have An Ms Flat Of 35X3 Mm Thickness Guar Support Rod 10Mm Ms Rod Welded , Thereafter Welded To The Top Can Be Fastened To The Upright Member To The Top So Obtained Study In Construction. The Head Rest Shall Have The Same Construction As The Top And It Shall Be Adjustable On A Rack For Obtaining Various Positions. The Rest Of The Details Shall Be According To 4 Of Ls:4033-1968. Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. Mattress: Foam 40 Density Suitable For Use With The Table, 2 Thickness, St Rexene Green Cover To Be Supplied With The Table; All Stitching Shall Be Done With Thread Of Griffon 40 Grade. Finish As Per General Condition Of Tender 50.00 Patient Cot For Adult With Mattress Scope: This Specification Is For The Requirement Of Iron Cots Suitable For General Purpose In Hospitals. Dimensions Over All Dimensions Of Cot Of Size Top Frame ( Sheet ) Shall Be Length 1910 Mm, Width 910 Mm And Height 600 Mm. The Various Tubes Used In Manufacture Of Iron Cots Should Have The Following Outside Diameter And Thickness. Component Outside Dia ( Mm ) Thickness ( Mm ) Bows Outer Cr Tubes -38.10.Mm X 1.60 Mm Cross Tubes Cr Tubes 25.40 X 1.22 Mm Filling Tubes Cr Tubes 19.05 Mm X 1.22Mm The Ms Flat For Top Shall Be Inside All Four Sides Of Size 50X3 Mm Minimum Thickness Of 3.0 Mm. Material: Frame Work Shall Be Of Cr Sheets Conforming To Is: 513 D Quality. Bows & Tubes: These Shall Be Made From Cr Steel Tubes. Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. Manufacture Head End: Construction Of The Head End Shall Comply To Meet Requirement Given Bows Shall Be Manufactured From Steel Tubes. It Shall Be Bent, With Inside Radius Of Not More Than 125 Mm At Top 2 Corners Cr Sheet Brackets . Bracket Of 3 Mm Thickness, Shall Be Welded With The Bows Vertical Upright Members Which Allows Frame To Rest On It An Cross Tube: One Horizontal Cross Tube For Making The Structure Of The Bow Rigid Shall Be Welded Between The Vertical Upright Members Of The Bows. Cross Tube Shall Be Welded Below The Sleeping Level At A Height Of 300 Mm From The Bottom. Filling Tubes: The Three Vertical Filling Tubes Shall Be Welded To The Cross Tube And To The Bow. They Should Be Spaced At Regular Intervals. The Height Of The Head End Bow Shall Be About 1075 Mm. Foot End Bow: It Shall Be Similar To 4.1.1 To 4.1.3 Except Leg Bows, Which Shall Be Of 810 Height. Mattress Platform: This Shall Comply With The Requirements Given Below:- The Bed Frame Shall Be Made From C.R. Sheet Double Bent. It Should Be Reinforced With Three Formed Channels To Size 20 X 50 X 50 X 50 X 20 Mm Of 1.25Mm Thickness Flanges Welded Inside The Length Wise. 50.00 Revolving Stool Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 +0.1 Cm. Thick Hot-Pressed Plywood Measured As Per Qa Method Described In Ocp-Qlta-P14-18 And Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. Overall Size: 1220 H X 500W X 460 D High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density = 45±2 Kg / Nr And Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression. Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. Center Tilt Synchro Mechanism: The Mechanism Is Designed With The Following Features: 360° Revolving Type. Upright Position Locking 1 Tilt Tension Adjustment Seat / Back Tilting Ratio Of 1:3. Tubular Frame: The Powder Coated ( Dft 40-60 Microns ) Tubular Frame Is Cantilever Type & Made Of 0 2.54 ±0.03Cm. X 0.2 ±0.016Cm.Thk. M.S. Er.W. Tube. Pneumatic Height Adjustment: The Pneumatic Height Adjustment Has An Adjustment Stroke Of 12.0±0.3Cm. Telescopic Bellow Assembly: The Bellow Is 3 Piece Telescopic Type And Injection Moulded In Black Polypropylene. Pedestal Assembly: The Pedestal Is Cr Sheet U Bend 2 Mm Thickness Chromium Coated And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.3 ±0.5Cm. Pitch-Centre Dia. ( 76.3 ±1.0Cm With Castors ) . Twin Wheel Castors ) : The Twin Wheel Castors Are Injection Moulded In Black Nylon. Finish As Per General Condition Of Tender 50.00 Patient Attendant Stool The Stool Shall Be Used For Bed Side Of The Patient For Their Attendants To Sit. Material Frame Work: As Given In Clause 1.1 Of General Requirements For Hospital Furniture. Top: Stainless Steel Sheet Conforming To Designation 04Cr18ni 10 Or 07Cr18 Ni9 And Shall Have A Thickness Of 1.20Mm. It Shall Also Conform To Of The General Requirements Of Hospital Furniture. Legs: The Legs And Supports Shall Be Made Of Square Pipe Of Size 25 X 25 X 1.6Mm Shoes: These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35 Mm. Dimensions. Top: 300Mm X 300Mm Height: 500Mm Height Manufacture: The Frame Work Of Stool Shall Have A Single Continuous Lengths Of Cr Steel Tubes As Shown In Figures Of Indian Standards. At The Floor End, The Four Upright Members Shall Be Connected Together By Longitudinal And Transverse Tie Rods Finish As Per General Condition Of Tender 40.00 3 Seater Visitor Chair Supply Of Orbit 3 Seater Visitors Chair, *Cushioned Seat And Back *Silver Grey Finish With Arms Model No. Sj-708La Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 20.00 Open Rack Steel Slotted Angular Racks, Open Type With 6 Shelves Making 5 Compartments Of Size 1800Mm X 900Mm X 450 Mm, Cr Sheet Shelfs 1.2Mm Thickness With An Angle Of 2 Mm Thickness And Size: 40 Mm X 60 Mm, With 8 Corner Brackets Of 2 Mm Thickness. Finish: Sheet Metal Components: All Dents, Burrs And Sharp Edges Shall Be Removed From The Various Components. The Components Shall Be Individually Pickled, Scrubbed And Rinsed To Remove Grease, Rust, Scale Or Any Other Foreign Element. Immediately After Pickling, All The Mild Steel Parts Shall Be Given Phosphate Treatment Conforming To Class C Or Is : 3618-1966. The Process For Application Of Phosphate Coating Shall Be In Accordance With Is: 6005-12970. Two Coats To Enamel Paint ( Colour Grey Is Preferred ) Shall Then Be Applied As Follows: Finish Coat With Enamel Paint Conforming To Is : 151-1950, Is : 2932-1974 Or Is : 2933-1975. In The Case Of Stoving Enamel The Components Shall Thereafter Be Backed At A Specified Temperature In An Over Heated Uniformly. The Finish Shall Be Smooth And Uniform With A Hard And Touch Film Of Enamel, Strongly Adhering To The Surface. The Finish Shall Be Free From All Visible Defects And Shall Not Chip When Tapped Lightly With A Dull Pointed Instrument. Note: Putty Shall Be Applied To All The Surfaces Requiring Filling And Shall Conform To Is: 110-1968. Tests: The Performance Tests Required For The Finished Racks Shall Be Carried Out As Per The Methodology Mentioned In The Is 6189:1985. The Rack Shall Have A Name Plate Or Label Fixed To It Showing The Manufacturer’S Name, Initials Or Recognized Trademark. Hospital Furniture Items Shall Be Subjected To Tests In Accordance With The Requirements Of Relevant Specifications. However, The Painted Furniture Items Shall Also Satisfy The Adhesion Test And In Addition Satisfy The Performance Test Give Below: Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 4.00 Table For Immunization / Fp / Counselling Dimensions: 900 W X 590 D X 750 H Mm Material : A ) Plb / Plt – Top Impregnated Base 18Mm Thickness With 2Mm Thick Hot Pressed Pvc Beading C ) Understructure : This Table Comes With A Square Tube Understructure With Prime Quality C.R Tube Steel. All Steel Tubes Used For Desk Under Structures Are As Per Is-3601-1984, Is- 7138-1973, Is-4923-1985. Top Frame And Legs :30 X 30 C.R Square Tube 1.2Mm Thickness With Two Foot Steps. 5.00 Table For Seminar / Conference Hall Conference Hall Table Size: 2100 X 1200 X 740 Mm. Table Top :- The Top Of The Table Shall Be Made Of 38 Mm Composite Mdf ( 25Mm Plain Mdf Board + 12Mm Plain Mdf ) With Pvc Membrane 0.4Mm Thick Pvc Membrane Foil Using Wrap Around Technology. The Foil Is Pre-Coated With Pu Layer For Better Scratch And Wear Resistance. 0.6Mm Balancing Laminate On Bottom Surface. Understructure :- The Legs Of The Table Shall Be 25 Mm Thk , Post Formed Particle Board With Round Edge. Modesty Panel :- The Modesty Panel Of The Table Shall Be 600Mm High Made Of 18Mm Thk Prelam Particle Board. Vertibrae Fixed To Work Surface From Bottom Side For Entering Wires The Wire Carrying Is Facilitated Through The Hollow Space Between Plastic Components.
Contract Date: Ref. Documents Contract Value : 26.89 Lakh
Government Departments No of Bidders 1
11.
Health and Family Welfare #11383742 AOC
Supply Of Furniture Items To Government Medical College At Suryapet In Suryapet District.=150 Student Cot With Mattress & Pillow 1 Scope: This Specification Is For The Requirement Of Iron Cots Suitable For General Purpose In Hospitals. 1.1 Dimensions 2.1 Over All Dimensions Of Cot Of Size Top Frame ( Sheet ) Shall Be Length 1910 Mm, Width 910 Mm And Height 470 Mm With Bushes. 2.2 The Various Tubes Used In Manufacture Of Iron Cots Should Have The Following Outside Diameter And Thickness. Component Outside Dia ( Mm ) Thickness ( Mm ) A Bows Outer Cr Tubes -38.10.Mm X 1.60Mm B Cross Tubes Cr Tubes 25.40 Mm X 1.22 Mm C Filling Tubes Cr Tubes 19.05 Mm X 1.22 Mm 2.3 The Ms Flat For Top Shall Be Inside All Four Sides Of Size 50X3 Mm Minimum Thickness Of 3.0 Mm. 3 Material: 3.1 Frame Work Shall Be Of Cr Sheets Conforming To Is: 513 D Quality. 3.2 Bows & Tubes: These Shall Be Made From Cr Steel Tubes. 3.3 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. 4 Manufacture 4.1 Head End: Construction Of The Head End Shall Comply To Meet Requirement Given 4.2 Bows Shall Be Manufactured From Steel Tubes. It Shall Be Bent, With Inside Radius Of Not More Than 125 Mm At Top 2 Corners Cr Sheet Brackets . Bracket Of 3 Mm Thickness, Shall Be Welded With The Bows Vertical Upright Members Which Allows Frame To Rest On It An 4.3 Cross Tube: One Horizontal Cross Tube For Making The Structure Of The Bow Rigid Shall Be Welded Between The Vertical Upright Members Of The Bows. Cross Tube Shall Be Welded Below The Sleeping Level At A Height Of 200 Mm From The Bottom. 4.4 Filling Tubes: The Three Vertical Filling Tubes Shall Be Welded To The Cross Tube And To The Bow. They Should Be Spaced At Regular Intervals. The Height Of The Head End Bow Shall Be About 610 Mm. 4.5 Foot End Bow: It Shall Be Similar To 4.1.1 To 4.1.3 Except Leg Bows, Which Shall Be Of 570 Mm Height. 4.6 Mattress Platform: This Shall Comply With The Requirements Given Below:- The Bed Frame Shall Be Made From C.R. Sheet Double Bent. It Should Be Reinforced With Three Formed Channels To Size 20 X 50 X 50 X 50 X 20 Mm Of 1.25Mm Thickness Flanges Welded Inside The Length Wise. With 3 Years Warranty Finish As Per General Condition Of Tender 100 Almarah Steel Full Size Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding &Ark Welding. Anticorrosion Treated Components. Dimensions Outer: 1980 H X 910 W X 480 D Mm Main Door With Shetters Top, Bottom Lh & Rh Sides, Shelves And Back All Materials Thickness Not Less Than 1 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside With 5 Compartments. Shelve Size 908 X 430 Mm Crca Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.0 Mm Range As Per Is-513 1994 ( Reaffirmed In1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. Hot Rolled Steel Used For Thickness 2.0 To 3.15 Mm Range As Per Is-1079 1994 Is-1079 1994 ‘D’ Quality Or Is-10748 1995 Grade-Ii. Chemical Composition, Tensile Properties, Bend Test, Surface Flaws, Roll Mark, Dent & Lines Etc. Weight 80 Kgs Finished General Condition With 3 Years Warranty Finish As Per General Condition Of Tender 100 Chairs For Office 1. Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 ±0.1Cm. Thick Hot-Pressed Plywood Measured And Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. The Chair Is Available In Three Models. Mid Back Size 47.5 Cm. ( W ) X 58.0 Cm. ( H ) *Pch-9U01rg / 9U02rg / 9U12rg Seat Size 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2. High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density = 45±2 Kg / M3 And Hardness Load 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3. Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4. Center Tilt Synchro Mechanism ( For 9U01rg / 9U02rg ) : The Mechanism Is Designed With The Following Features: · 360° Revolving Type. · 3 Position Locking · Tilt Tension Adjustment 5. Tubular Frame ( For 9U12rg ) : The Powder Coated ( Dft 40-60 Microns ) Tubular Frame Is Cantilever Type & Made Of Ø 2.54 ±0.03Cm. X 0.2 ±0.016Cm.Thk. M.S. Er.W. Tube. 6. Pneumatic Height Adjustment ( For 9U01rg / 9U02rg ) : The Pneumatic Height Adjustment Has An Adjustment Stroke Of 12.0 ±0.3Cm. 7. Telescopic Bellow Assembly ( For 9U01rg / 9U02rg ) : The Bellow Is 3-Piece Telescopic Type And Injection Moulded In Black Polypropylene. 8. Pedestal Assembly ( For 9U01rg / 9U02rg ) : The Pedestal Is Injection Moulded In Black 33%Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.3 ±0.5Cm. Pitch-Centre Dia. ( 76.3 ±1.0Cm With Castors ) . 9. Twin Wheel Castors ( For 9U01rg / 9U02rg ) : The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.3 Cm. Depth ( D ) : 76.3 Cm. Height ( H ) : 85.5-97.5 Cm. Seat Height ( Sh ) : 42.5-54.5 Cm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 50 Teachers Classroom Table Lecture Table Size: 1500 L X 600 D X 750 Ht System: Angular Legs Specification: Table Top: 25Mm Thick Pre-Laminated Particle Board Finished With 2Mm Pvc Edge Banding On All Exposed Edges. Under Structure: Ms Powder Coated Switch Angular 40X40 Legs And Ms Powder Coated Cross Beams ( 40X20 ) Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge.. 250 Examination Hall Table 1 Dimensions: 750 Mm X 450 Mm X 750 H Mm 2 Material : 2.1 A ) Plb / Plt – Top 2.2 Impregnated Base 18Mm Thickness With 2Mm Thick Hot Pressed Pvc Beading 2.3 C ) Under Structure : This Table Comes With A Square Tube Under Structure With Prime Quality C.R Tube Steel. 3 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601-1984, Is- 7138-1973, Is-4923-1985. 4 Top Frame And Legs :30 X 30 C.R Square Tube 1.2Mm Thickness With One Foot Steps. 5 These Shall Be Manufactured From Pvc Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm With 3 Years Warranty Finish As Per General Condition Of Tender 120 Lecture Hall Dual Desk Bench For ( 2 ) Students Genii 2Strfr+Rr Plt Choco Sm6 1240 X 1130 X 757 Desk-Top Panel-All Panels Are Made From 18Mm Thk Pre-Laminated Twin Board ( E1 / P2 Grade ) With Pvc Edge Banding On All Sides.The Panels Have Cornersrounded For Safety Usage. Understructure - All Side Metal Frames And Cross Connectors Are Made From Combination Of 25.4 X1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes , 31.8 X 1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes And 28.6 X 1.2 Mm Thk ( Approx. 18 Swg ) Round Erw Tubes ( As Per Is:7138 ) Which Are Welded Together.The Welded Structures And Cross Connectors Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.Back Supports Which Are Provided At The Rear Back Are Made Of 50.8 X 25.4 X 1.2 Mm Thk ( Approx. 18 Swg ) Rectangular Erw Tubes ( As Per Is:7138 ) .The Tubes Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.The Storage Shelves Are Made From 0.6 Mm Thk Ms Sheet ( As Per Is:513 ) Fixed Below The Radesk Top Panel And Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating. Hooks Are Provided On The Vertical Side Frames On Both Sides Of The Desk For Hanging Bags / Bottles. They Are Made From 2 Mm Thk Ms Sheet ( As Per Is:513 ) And Are Coated With Min. 45 Micron Thickness Of Epoxy Polyester Coating.The Understructure Is Assembled Using M6 Trilobular Screws ( As Per Din 7500 ) With Zn Blue Plating.Compact Laminate Seat And Back Panels Are Assembled Using M6 Counter Sunk Trilobular Screws ( As Per Din 7500 ) With Zn Black Plating ( As Per Is 1573:1986 ) Spacers Are Provided On Th Top Of Round Tubes For Wooden Panels Fixing. They Are Made Of Made Glass Filled ( 30% ) Plastic Caps Made Of Pp Copolymer ( 3530 Grade ) Are Also Provided On The Rear Frames Adding More Aestheic Value To The Product.M6 High Tensile Tvs Make Bolt ( Class 8.8 ) With Glasss Filled Nylon Level Adjustors Are Provided At The Bottom Of Understructure To Take Care Of Unevenness In Floor With Height Adjustment Of Approx 15Mm Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge.. 25 Table ( Office Table Big Size ) 1 Dimensions:1450 W X 680 D X 750 H ( In Millimetres ) 2 Material: 2.1 A.Plb / Plt - Top 25 Mm Thickness. 3 All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 4 Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 5 Each Plb / Plt May Contain Following Material Layers: 6 Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 7 C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. 8 D. Storage: 3 Draw & 2 Draw Metal Is Provided For Storage. One Side 2 Draw And Other Side 3 Draw Metal Shall Be Provided. 9 Drawer: • Box-Box-File : Dimensions 390 W X 430 H X 560 D Mm, Construction & Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Think. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels 10 All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 11 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 12 Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 500 Student Study Table 1 Study Table Of Size 1200 Mm X 600Mm X 750Mm Having Wood Laminate Finish The Table Top / Work Surface: Made From 25Mm Thick Plb With Pvc Lipping. Side Panels: Made From 18Mm Thick Plt With Pvc Lipping. Modesty Panel: Made From 18Mm Thick Plt With Pvc Lipping. Neat Wiring Flow With Cut-Outs On Both Sides, Free Standing Pedestal For Adequate Personal Storage. 2 Material: 3 A.Plb / Plt - Top 25 Mm Thickness. 4 All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 5 Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 6 Each Plb / Plt May Contain Following Material Layers: 7 Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 8 C. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Squre Tube 1.22Mm Thickness. 9 D. Storage: Single Drawer Is Provided For Storage With Right Side With Metal Shall Be Provided. 10 Drawer: • Box-Box-File : 550 X 420 X 390, Construction &Material:Welded Assembled, Crca As Per Is-513.• Back , Sides, Top & Bottom , Box 0.6 Thick. Drawer Tray & Front- 0.8 Mm. Crca As Per Is-513 , Drawer Slides Used Must Be Of Heavy Duty Telescopic Channels 11 All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 12 All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 13 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. 14 Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 60 3 Seater Visitor Chair Supply Of Orbit 3 Seater Visitors Chair, *Cushioned Seat And Back *Silver Grey Finish With Arms Model No. Sj-708La Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Almarah Steel Full Size Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding &Ark Welding. Anticorrosion Treated Components. Dimensions Outer: 1980 H X 910 W X 480 D Mm Main Door With Shetters Top, Bottom Lh & Rh Sides, Shelves And Back All Materials Thickness Not Less Than 1 Mm Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside With 5 Compartments. Shelve Size 908 X 420 Mm Crca Steel: Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.0 Mm Range As Per Is-513 1994 ( Reaffirmed In1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Open Rack 1 Steel Slotted Angular Racks, Open Type With 6 Shelves Making 5 Compartments Of Size 1800Mm X 900Mm X 450 Mm, Cr Sheet Shelfs 1.2Mm Thickness With An Angle Of 2 Mm Thickness And Size: 40 Mm X 60 Mm, With 8 Corner Brackets Of 2 Mm Thickness. 2 Finish: Sheet Metal Components: All Dents, Burrs And Sharp Edges Shall Be Removed From The Various Components. The Components Shall Be Individually Pickled, Scrubbed And Rinsed To Remove Grease, Rust, Scale Or Any Other Foreign Element. Immediately After Pickling, All The Mild Steel Parts Shall Be Given Phosphate Treatment Conforming To Class C Or Is : 3618-1966. 3 The Process For Application Of Phosphate Coating Shall Be In Accordance With Is: 6005-12970. Two Coats To Enamel Paint ( Colour Grey Is Preferred ) Shall Then Be Applied As Follows: Finish Coat With Enamel Paint Conforming To Is : 151-1950, Is : 2932-1974 Or Is : 2933-1975. In The Case Of Stoving Enamel The Components Shall Thereafter Be Backed At A Specified Temperature In An Over Heated Uniformly. The Finish Shall Be Smooth And Uniform With A Hard And Touch Film Of Enamel, Strongly Adhering To The Surface. The Finish Shall Be Free From All Visible Defects And Shall Not Chip When Tapped Lightly With A Dull Pointed Instrument. Note: Putty Shall Be Applied To All The Surfaces Requiring Filling And Shall Conform To Is: 110-1968. 4 Tests: The Performance Tests Required For The Finished Racks Shall Be Carried Out As Per The Methodology Mentioned In The Is 6189:1985. The Rack Shall Have A Name Plate Or Label Fixed To It Showing The Manufacturer’S Name, Initials Or Recognized Trademark. 5 Hospital Furniture Items Shall Be Subjected To Tests In Accordance With The Requirements Of Relevant Specifications. However, The Painted Furniture Items Shall Also Satisfy The Adhesion Test And In Addition Satisfy The Performance Test Give Below: 6 Shoes: These Shall Be Manufactured From Pvc / Hard Rubber Bush. Nominal Height Of The Shoe Shall Be 35 Mm. Outside Dimensions Of 3Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 25 Dining Table With Benches Supply Of Dining Table, Specification: Size 93 L X 30W X 30H With 8 Seater, Top In 18 Gauge Of 304 Grade Stainless Atell , Legs In 1 1 / 2 X 1 1 / 2 Square Tube Stainless Stell In 16 Gauge Of 304 Grade With Foldable Benches As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 25 Library Table Size: 1800 X 900X 750 Mm The Understructure Should Be Available In Cr Square Tube. It Should Be Fixed And Shall Accommodate 6 People The Table Top Should Be 25 Mm Thick Pre Laminated Particle Board With Teak Wood Beading 40 Mm Thickness With Polish Top Frame And Legs Crs Quare Pipe 40X40 Mm, 1.6 Mm Thickness With 6 Legs Two Support Footrust With 35 H X 3Mm Pvc Bush. With 3 Years Warranty Finish As Per General Condition Of Tender 5 Principal Table Supply Of Cabin Table, Main Table Of Size 2400 L X 900 D X 750 Ht, Side Composite Storage Unit Size 1350 L X 450 D X 750 Ht, System - Enrich Series. Specifications: Table Top: 25Mm Thick Pre-Laminated Particle Board With 2Mm Pvc Edge Lipping On All Exposed Edges. Under Structure: Supported On Chrome Plated Enrich Legs Supporting On Ms Powder Coated Cross Beams ( 40X20 ) . Modesty Panel: 18Mm Thick Plt Modesty Panel Of 450Mm Ht. Wire Management: Anodised Finish 350 X 150 Flip Up Box With Soft Closures, Without Sockets And Switches Are Provided, Pvc Cable Dump & Vertical Wire Entry Cover For Wire Uptake From Floor To Cable Tray. Storage Unit Top - 25Mm Thick Pre Laminated Particle Board With 2Mm Pvc Edge Lipping. Body, Shelfs & Shutters – 18Mm Thick Pre Laminate Particle Board With 2Mm Pvc Edge Lipping. Back – 9Mm Thick Pre Laminate Particle Board With 2Mm Pvc Edge Lipping. Lock - Regular Lock. Handle - Finger Grooves Hardware – Door Closing Hinges, Mini-Fix, Levellers & Locks, Etc., Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 5 Executive Chair For Principal Pulse Hb Mb Seat, Adj. Arms Larger Seats Head Rest 1.Seat / Back Assembly: The Seat Is Made Up Of 1.5 ± 0.1Cm Thk. Hot Pressed Plywood Measured. The Back Is Made Up Of Injection Moulded Glass Filled Polypropylene & Upholstered Using Net Fabric With High Tenacity Yarn. *Seat Size ( Larger Seat Depth ) { Pulsal } : 47.0 Cm. ( W ) X 51.5 Cm. ( D ) *Back Size ( Pulsax, Pulsal ) : 45.0 Cm. ( W ) X 65.3 Cm. ( H ) 2.High Resilience ( Hr ) Polyurethane Foam: The Hr Polyurethane Foam Is Moulded With Density =55+ / -2 Kg / M3 And Hardness 16 ± 2 Kgf As Per Is:7888 For 25% Compression. 3.Armrests ( Adjustable ) { Pulsax, Pulsal } : The Adjustable Armrest Is Designed With The Following Features: •Up-Down Adjustment- 6 Steps ( 7.2 ± 0.5Cm Range ) •Armrest Top Is Mounted On Armrest Structure Made Of Glass Filled Nylon. •Armrest Top Is Pu Moulded Over Glass Filled Nylon Insert. 4.Lumbar Support Assembly: The Lumbar Support Consists Of Polypropylene Pad.The Height Of Lumbar Pad Can Be Adjusted Through Two Projecting Knobs Provided On The Rear Side Of The Pad. Lumbar Pad Has An Adjustment Of 8.0 ± 0.5 Cm In Height. 5.Front Pivot Synchro Mechanism: The Adjustable Tilting Mechanism Is Designed With The Following Features. •360° Revolving Type. •Single Point Control. •Front-Pivot For Tilt With Feet Resting On Ground Ensuring More Comfort. •Tilt Tension Adjustment. •4-Position Locking With Anti-Shock Feature. •Seat / Back Tilting Ratio Of 1:2. 7.Pneumatic Height Adjustment: The Pneumatic Height Adjustment Has An Adjustment Stroke Of 10.0 ± 0.3 Cm. 8.Pedestal Assembly: The Pedestal Is Injection Moulded In Black 30% Glass-Filled Nylon And Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Pitch-Center Dia Is 066.1 ± 0.5 Cm. ( 76.1 ± 1.0 Cm. With Castors ) . 9.Twin Wheel Castors: The Twin Wheel Castors Are Injection Moulded In Black Nylon. Overall Dimensions Of Chair Width ( W ) : 76.1 Cm Depth ( D ) : 76.1 Cm Height ( H ) : 98.0 - 108.0 Cm Seat Height ( Sh ) : 45.8 - 55.8 Cm. Neckrest : The Neckrest Assembly Consist Of Polypropylene Pad With Moulded Polyurethane Foam & Covered With Polyester Fabric Neckrest Is Fixed To Back Assembly Through Neckrest Connector Neckrest Assembly Has Height Adjustment Of4.2 + 0.5 Cm And Rotation Adjustment Of Overall76”+ 2”. The Complete Neckrest Assembly Is Retro Fit To The Main Chair Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 50 Alamarah With Acrylic ( Glass ) Door 1. Multi Bend Construction And Inter Locking Design And Full Length Over Lapping Doors And Side. Three Way Bolting Mechanism. Spot Welding & Co2 Welded. Front Side Doors With Acrylic Transparent Sheet All Round Frame 70 Mm Borders Thickness 5.5 Mm Thickness 2. Dimensions Outer: 1980 H X 910 W X 480 D Mm 3. A. Top, Bottom, Lh & Rh Sides And Back Material Thickness- 1 Mm 4. B. Removable Rh & Lh Main Doors With Stiffeners Material Thickness =1.22 Mm 5. Almariahs To Be Provided With 4 Full Fixed Shelves Of Inside Shelve Size Of 908 W X 420 D Of Thickness -1 Mm 6. Cr Steel: 7. Cold Rolled Close Annealed Steel Used For Thickness 0.6 To 1.2 Mm Range As Per Is-513 1994 ( Reaffirmed In 1998 ) . Grade ‘D’ Or ‘Dd’ Quality. Chemical Composition, Tensile Properties, Bend Test, Surface, Flatness, Hardness As Per Is-513 1994. 8. Finish As Per General Condition Of Tender With 3 Years Warranty Finish As Per General Condition Of Tender 25 Office Table With Draws ( Office Table Small Size ) 1. Dimensions:1200 W X 600 D X 750 H Mm 2. Material: 2.1 A.Plb / Plt - Top 25 Mm Thickness. 3. All Plb And Plt ( Prelaminated Twin ) Is Of Following Grade. 4. Grade Ii Type Ii – Designation – Plb-22 ( As Per Is: 12823 – 1990 ) 5. Each Plb / Plt May Contain Following Material Layers: 6. Particle Board, Top With 2Mm Thick Hot Pressed Pvc Beading With Keyboard Moulded Type. 7. Under Structure: This Table Should Be Square Cr Tube 30 X 30 Under Structure With Prime Quality C.R Steel Square Tube 1.22Mm Thickness. 8. D. Storage: 3 Draw Is Provided For Storage. With Right Side With Metal Shall Be Provided. 9. Body For Storage Units: Body And Draws For Storage Unit Dimensions 390 W X 430 H X 560 D Mm Shall Be Made From Cr Steel Sheet Not Less Than 0.8 Mm Thick With Heavy Duty Telescopic Channels. This Shall Be Bent To Box Shape From One Piece And Tack Welded At Final Overlapped Comer Or Assembled With A Maximum Of Two Pieces Properly Welded 10. All Steel Metal Components Are Manufactured From Finest Quality Steel, Which Conforms As Per Is-513 Grade D, Dd 11. All Steel Tubes Used For Desk Under Structures Are As Per Is-3601 – 1984, Is-7138-1973, Is-4923-1985. 12. Shoes - These Shall Be Manufactured From Hard Rubber Or Pvc And Shall Be Uniform In Texture And Chemically Inactive To The Action Of Mild Acids. The Nominal Height Of The Shoes, Shall Be 35Mm. With 3 Years Warranty Finish As Per General Condition Of Tender 200 Office Chairs S Type With Armrest ( Nursing Station ) Supply Of Class Room Chair And Hostel Room Study Chair, Cushioned Seat & Plastic Back Without Arms & With Powdercoated Legs With Bushes, Magna Va - Plastic ( Pc ) Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. With 3 Years Warranty Finish As Per General Condition Of Tender 3 Examination Couch Examination Table On Ratchet With No Storage Overall Dimension Of L 1830Mm X W 600Mm X H 850 Mm. The Backrest Has Ratchet Mechanism For Tilting The Backrest. Leg Frames & Intermediate Frames Is Made Of Erw Tubes Having Section Of 30 X 30 Square Tubes With Thickness Of 1.6Mm. Nylon 6 Leg Shoes Is Given To Avoid Wear & Tear. Ms Sheet Metal Lying Surface Of Thickness 1.2Mm Is Used. Top Sheet Metal Panel Base Frame Of 25 X 25 Erw Square Tubes Of Thickness 1.6Mm Is Used. Ratchet Is Of Ms Strip With Section 40 X 4 To Provision The Backrest Tilt. All Ms Part Are Pre Treated And Powder Coated With Ral White Color & All Plastic Parts In Grey. Safe Working Load Is 135Kg Of Featherlite / Godrej Or Equavalent As Directed By The Engineer-In-Charge. 500 Student Chair With Pad Royal Visitor S Type Pad Chair Cushion Seat And Back Cushion Foam And Quality Moulded Ply With Pu Handles With 1 Hr Round Pipe 16 Gauge With Fabric With 18 Mm Pre-Laminated Writing Pad. All Hr Pipes Section Are Shall Be Pre-Treated And Epoxy Powder Coated 50-60 Microns Thickness With 3 Years Warranty Finish As Per General Condition Of Tender
Contract Date: Ref. Documents Contract Value : 1.31 Crore
Government Departments No of Bidders 1
12.
Public Administrative Department #11382445 AOC
Tender For Annual Plan-Pro.No 315/26 Crematorium Construction In Avanur Gp 2025-26-Avr 315/26-General Civil Work - Building construction 2 2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil 3 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 4 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5 OD316310/2025-2026:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site . Modified from 60.7.1 6 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 7 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 8 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 9 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 10 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 11 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 12 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 13 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 14 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15°landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III)derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 15 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 16 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 17 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 18 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 19 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 20 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 21 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 22 21.3.3:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness(weight not less than 20 kg/sqm) 23 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 24 11.20.2:Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Medium shade pigment using 50% white cement 50 % Grey cement 25 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 17.7.2:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap 27 17.2.2:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid 28 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 29 18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 30 18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 31 50.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall 32 50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall 33 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 34 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 35 17.29:Providing and fixing 100 mm sand cast Iron grating for gully trap. 36 OD325929/2025-2026:Supply and fixing PVC frame and shutter for doors of size of (0.8mX2.00m)including cost of labour and materials as per direction of departmental officers. 37 OD326277/2025-2026:Supplying and fixing Pressed Steel Door of standard pattern with frames as per profile of IS:4351 of section 105*60mm using 18G (1.2mm thick CRCA) sheet and shutters made of section 75*30mm of outer styles and horizontal members and then inserted with enclosed and stiffened sheet 26CR as per the specification with zinc chromate primer including all charges of fittings, conveyance etc, complete.steel door of size 120*210 cms 38 51.19.ST2:Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 2. 15 to below 25 flush capacity 39 OD326287/2025-2026:Ferrow cement soak pit 75 cm dia and 75 cm height 40 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 41 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 42 10.6.2:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover 43 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 44 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 45 OD326395/2025-2026:supplying and fixing 150mm half cut section with brackets at the end of sheet or tiled roof for rain water collection including all cost and materials , conveyance, labour charges etc. 46 OD330008/2025-2026:Roofing with Premium Aluzinc roofing powder coated Tiled design sheet with matte finishing 0.5mm thick or nearest available thickness with overlaps of 150mm at ends and G I hook or screw or crank C I bolts and nuts including plain and bitumen washers etc completed.
Contract Date: Jun 27, 2026 Contract Value : 30.93 Lakh
Government Departments No of Bidders 3
13.
Public Administrative Department #11367794 AOC
Tender for Annual Plan-Kondotty Municipality 2025-26-Proj No - 161/26 Fhc Renovationward - 28-General Civil Work--1 FHC HALL1.001 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete1.002 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete1.003 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work1.004 50.6.5.2:Hollow block masonry using pre cast blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part 1 of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete1.005 11.41.1:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.1.006 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)1.007 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work1.008 OD430235/2025-2026:Supplying and fixing 10 mm thick cement fibre sheet, including all costs , conveyence and labour charges as per standard specifications.1.009 OD425528/2025-2026:Providing and fixing granite of any colour and shade for name board of required size laid over base of cement mortar 1:4 including all charges etc complete at all levels ,including lettering & fixing
Contract Date: Jun 25, 2026 Contract Value : 3.97 Lakh
Government Departments No of Bidders 2
14.
Water Resources and Irrigation #11342285 AOC
Amrut-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipment For 107 Mld Sewerage Treatment Plant At Muttathara-Supply, Erecting And Commissioning Of Various Pump Sets, Other Necessary Equipments For 107 Mld Sewerage Treatment Plant At Muttathara-Sewerage Work- 1 SUPPLY, ERECTING AND COMMISSIONING OF PUMP SETS 2 OD149149/2023-2024:Supply, Erecting and Commissioning of 75 HP non clog pump set for RAS (Head – Up to 20 M) 3 OD149154/2023-2024:Supply, Erection and Commissioning of 5 HP non clog pump set for WAS (Total Head :14 M ) 4 OD149153/2023-2024:Supply, Erecting and Commissioning of 5 HP centrifugal dewatering pump set for RAS 5 OD17699/2025-2026:Supply, Erecting and Commissioning of80 HP Submersible pump set for inlet(Head : Up to 20 M) 6 OD18102/2025-2026:Supply, installation, and commissioning of minimum 100 LPH RO water purifier of standard make with 304-grade stainless steel skid and housing, comprising multi-stage purification system including pre-filter, sediment filter, activated carbon filter, RO membrane, UV disinfection unit, auto-flush system, and mineral cartridge; suitable for continuous commercial use and delivering safe, high-quality drinking water. 7 OD18758/2025-2026:Supply of 10 HP portable submersible sludge pump, 3-phase, suitable for handling slurry and sewage, maximum head up to 20 meters, solid handling capacity up to 50 mm, abrasion-resistant impeller, thermal protection, 15 m power cable, and 30 meters of heavy-duty discharge hose (100 mm dia) with quick couplings. 8 Supply and installation soft starter and motorized chain pulley 9 OD149170/2023-2024:Supply of motorized chain pulley block with 3-ton lifting capacity and 10-meter lift height, featuring electric motorized operation with electromagnetic or disc brake system, pendant control for easy operation, limit switches for safety, and overload protection, conforming to IS/ISO standards. 10 OD16970/2025-2026:Supply and installation of soft starter for MCC unit ( For 60 HP motor XS4000,115A,M200-525VACC110/ 220VAC), MNX140 3P 240V CONTACTOR and SEMI CONDUCTOR FUSE 170M3015 11 OD18097/2025-2026:Supplying, fixing, and testing 50W LED hanging type well glass light, weatherproof (IP65) 12 OD18264/2025-2026:Supply and installation of 10-meter hot-dip galvanized double-arm octagonal street light pole with 2×120W LED luminaires, including internal wiring, weatherproof junction box, connections, and earthing. Complete with foundation bolts and RCC pedestal. Includes supply, erection, and commissioning 13 Installation of CCTV camera 14 OD16801/2025-2026:Supplying & fixing HIKVISION 5 MP Varifocal IP Bullet Camera CAMERA 15 OD16892/2025-2026:Supplying, fixing and commissioning 4MP IP DOME CAMERA 16 OD16891/2025-2026:Supplying, fixing and commissioning HIKVISION 4MP IP BULLET CAMERA 40M 17 OD16890/2025-2026:Supplying, fixing and commissioning HIKVISION 32CH NVR 18 OD16889/2025-2026:Supplying, fixing and commissioning 8 PORT POE SWITCH 19 OD16888/2025-2026:Supplying & fixing 6U RACK & ACCESSORIES 20 OD16887/2025-2026:Supplying & fixing 9U RACK& ACCESSORIES 21 OD16886/2025-2026:Supplying & fixing CAMERA BOX 22 OD16885/2025-2026:Supplying & fixing CAT6 CABLE & PIPING (including excavation) 23 OD16884/2025-2026: Supplying and fixing pole with all accessories. 24 OD16920/2025-2026:Supplying and fixing 55-inch, 4K, LED, Smart TV (Samsung/LG/Sony) 25 OD16919/2025-2026:Supplying & fixing RECEIVER & TRANSMITTER UNIT 26 OD16918/2025-2026:Supplying & fixing L & T EXTENSION 5MTR 27 OD16917/2025-2026:Supplying & fixing 5 PORT GIGABYTE SWITCH 28 OD16916/2025-2026:Supplying & fixing HDMI CABLE 3MTR 29 OD16915/2025-2026:Supplying & fixing RACK & PIPE ACCESSORIES, 30 OD16914/2025-2026:INSTALLATION CHARGE FOR CAMERA& NVR 31 OD16913/2025-2026:Supplying & installation of rack 32 New Road formation: Tarring inside STP compound 33 3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m 34 4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method 35 4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 36 5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means. 37 5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. 38 OD18679/2025-2026:Providing 40mm premixed chipping carpet over BT surface with departmental broken stones after thoroughly cleaning the base with wire brushes, brooms and applying a priming coat of hot bitumen @2.50Kg/10m2 and spreading the hot premix of 0.32m3 of 24mm, 0.22m3 of 12mm departmental metal mixed with 22.08Kg of bitumen per 10m2, rolling to dense surface, then spreading the seal coat comprising of 0.09m3 of 6mm metal mixed with 8.64kg of bitumen per 10m2 and rolling again including cost of bitumen, fuel, hire charges machineries etc. complete excluding the cost of 24mm ,12mm ,6mm metal(Total usage of bitumen 33.22 Kg per 10m2) (I.R.C 3.4.2) 39 OD18716/2025-2026:Supplying and stacking 24mm hard blue granite broken stone in standard heaps-for measurement(IRC 3.2. 1.a) 40 55.2:Supplying and stacking 12mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 41 55.3:Supplying and stacking 6mm hard blue granite broken stone in standard heaps for measurement(IRC 3.2.1.a) 42 Infrastructure Improvement Works at STP 43 OD17712/2025-2026:Supply and installation of UV-resistant HDPE with 12mm mesh ( 2meter height) for durability. Support poles are galvanized iron pipes (2-inch dia, 6 ft height) for stability. Stainless steel clamps & UV-resistant plastic ties ensure secure fitting. Concrete footing with excavation and earthwork provides pole stability. Skilled labor ensures proper installation 44 OD17711/2025-2026:Supply and spray a non-toxic, bio-friendly herbicide or a selective herbicide, with an application rate of 5 to 10 liters per hectare, ensuring effective weed control over an area of 1 hectare. 45 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 46 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 47 4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) 48 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 49 5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars 50 OD17710/2025-2026:Supply & installation of high-quality polyester sun control film with UV-blocking, heat resistance (99% UV, 60% heat rejection), 2–4 mil thickness, bubble-free installation, and 5-year warranty. 51 OD17709/2025-2026:Fire extinguishers (10L dry powder and 4.5kg CO₂) shall be installed as per IS: 2190 with inspection cards. Fire buckets with MS stands, safety posters, and caution notices in Malayalam and English shall be provided for compliance. 52 Providing roofing for DG, Inlet outdoor panels and mechanical screener 53 100.98.1009:Engaging Fitter ( grade 1). 54 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 55 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 56 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 57 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 58 50.12.1.1:Providing & fixing PVC corrugated roofing sheets of good quality up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8 mm dia G. I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 59 4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns 60 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 61 Replacement of leaking flanged pipes inside the inlet well 62 OD17790/2025-2026:Supply, conveyance, and fixing of 300mm double flanged DI K9 pipe, including scaffolding, fabrication if required (cutting, flange welding), and providing necessary fittings, nuts, bolts, rubber gaskets, and insertion rubber sheets for proper and safe installation at site. 63 OD17835/2025-2026:Dismantling existing 300 mm DI pipes carefully using crane/manual handling with all necessary safety measures, and stacking the removed materials within 50 meters as directed by the Engineer-in-Charge 64 Provision forEntry of Trucks from Rear Side of STP 65 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 66 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 67 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 68 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 69 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 70 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 71 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 72 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 73 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 74 13.82.1:Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.One coat 75 10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes 76 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 77 Security room (4m x 3m) at back entrance of STP 78 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 79 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 80 50.6.1.1:Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 81 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 82 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 83 50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. 84 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). 85 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 86 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 87 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 88 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 89 OD17944/2025-2026:Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including MS grill with suitable spacing and ISI marked M.S pressed butt hinges bright finished of required size with necessary locking arrangements. 90 OD17947/2025-2026:Electrical work including internal lighting, fan, switches, DB, concealed wiring, and one external LED light with pole/bracket for night visibility, complete with connections, fittings, and testing as per direction of Engineer-in-Charge. 91 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Contract Date: Jun 23, 2026 Contract Value : 2.52 Crore
Local Bodies No of Bidders 1
15.
Power #11334917 AOC
Tit-bit civil work along with Repair and Maintenance of Chakdha (west) CCC Building. (Estimate as per P.W.D. S.O.R.Vol I &II for the area of Kalyani Sub-Division in the district of Nadia w.e.f. 01.11.17 and all other corrigenda uptodate ) - 1 Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m .a) In ground floor including roof 2 b) In first floor 3 Dismantling all types of masonry excepting cementconcrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directedwithin a lead of 75 m.a) In ground floor including roof 4 b) In first floor 5 Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m.In ground floor including roof.(a) upto 150 mm. thick 6 b) In first floor 7 Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof 8 b) In first floor 9 Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil butexcluding laterite or sandstone) including removing,spreading or stacking the spoils within a lead of 75 m.as directed. The item includes necess-ary trimming thesides of trenches, levelling, dress-ing and ramming thebottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm 10 Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis ofmeasurement of finished quantity of work)(a) With earth obtained from excavation of foundation 11 Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. 12 Cutting holes and subsequent mending good damages. (a) Diameter upto 150 mm. (i) In brick work [Cement-4.0 Kg/Mtr] 13 Cutting chase upto 125 x 150 mm. and subsequentmending of damages.(a) in brick wall [Cement-3.6 Kg/Mtr] 14 Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineerin charge. 15 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 16 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any as per relevant IS codes. a) Pakur Varietya) In ground floor 17 b) In first floor 18 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominalsize) excluding shuttering and reinforcement,if any, in gound floor as perrelevant IS codesPakur variety 19 1st floor 20 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Varietya) In ground floor 21 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.a) For works in foundation, basement and upto roof of ground floor / upto 4m.(iii) other manufacturers not specified. 22 Brick work with 1st class bricks in cement mortar (1:6)a)in foundation & plinth 23 In Super structure, ground floor 24 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.a) In ground floor 25 b) In first floor 26 Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) Wall-------------------------With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m-----------ii) Other than Coloured decorative including white----------i) Gr.floor 27 A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m& joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m----- Other than Coloured decorative including white-------i) Gr.floor 28 Supplying and laying true to line and level vitrified tiles ofapproved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cement slurry back side of tilesusing cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stonefloor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM belowmortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal ofwax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finishcomplete including the cost of materials, labour and all otherincidental charges complete true to themanufacturer sspecification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be suppliedby the contrr]e)I(I) With application slurry @1.75 kg/ Sq.m, 20 mm sandcement mortar (1:4) & 2 mm thick cement slurry at back sideof tiles, 0.2 kg/ Sq.m white cement for joint filling withpigment.(A) Light colour(Gr.floor) 29 (ii) First floor 30 Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick)----------(i) Ground floor 31 In 1sl floor 32 Labour for taking out door and window frame including shutter for repair orreplacement of different parts of the frame & refixing the same including mendinggood all damaes complete. (Concrete and brick work for mending damage will bepaid separately)(a) Upto area 2.5 Sq.m 33 M.S. or W.I. ornamental grill of approved design joints continuously welded with M.S. W.I. flats and bars for windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.i) Grill weighing above 16 Kg./sqm------------a) In ground floor 34 b) In first floor 35 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) 36 1st floor 37 M.S. structural works in columns, beams etc. with simple rolledstructural members (e.g. joists, angle, channel sections conformingto IS: 226, IS: 808 & SP (6)- 1964 connected to one another withbracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming toIS: 816- 1969 & IS: 1995 using electrodes of approved make andbrand conforming to IS:814- 2004, haulage, hoisting and erectionall complete. The rate includes the cost of rolled steel section,consumables such as electrodes, gas and hire charge of all tools andplants and labour required for the work including all incidentalchages such as electricity charges, labour insurance charges etc 38 Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufacture from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position,straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing fixed with neceessary clamps and nuts and bolts and erected complete.(ii) below 50mm.Fixed type steel windows as per IS sizes with horizontal glazing bars 39 (b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only] 40 steel peg stay 300 mm long including fitting and fixing. 41 Two point nose steel handle including fitting and fixing. 42 Taking out M.S. or W.I. Grills from wooden frame including cuttinglugs from masonry wall and refitting the same and mending gooddamages after repairs. (Excluding the cost of necessary repair ofdamages) or doing any other necessary works 43 Easing, oiling and adjusting the steel shutters including scraping allmembers and fitting so as to make the shutters easily operable (noextra payment will be made for taking out and fixing glass, ifnecessary). 44 Renewing M.S. members of steel shutters by welding including takingout the old, mending good damages complete, including taking outand refixing the glass panes. 45 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).(c) Sal : Locala) In ground floor 46 Panel shutters of door and window, as per design (each panel consisting of singleplank without joint), including fitting and fixing the same in position butexcluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. 47 Brass floor door stopper. 48 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed. a) With continuous plate base (Hexagonal / Round rod), (i)75 mm grip x 10 mm dia rod. 49 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark.vi) 100mm. X 75mm. X 3.5 mm 50 Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws:ix) 300mm long x 10mm dia. bolt. 51 Anodised aluminium Aldrop / Sliding bolts of approved quality manufacturedfrom extruded section conforming to I.S. specification (I.S. 2681/66) fitted andfixed complete.----------300mm x 16mm dia. Bolt 52 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. 53 PVC Door Shutter-37 mm thick-Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc. In ground floor. 54 Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work).In 10-12 Micron thickness Annodizing film. i)natural White k) Movable door shutter .Door frame (top & sides) 55 ii) Shutter :Top rail 56 Bottom rail 57 Door Vertical 58 Lock rail 59 Glazing cleap 60 Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections for the following units:- (B) Partly glazed partly panelled or fully glazed single leaf alunminiumswing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry setneoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. 61 Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987. i) 4mm thick clear glass. 62 5mm thick clear glass 63 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filledwith foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) . (b) 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) 64 Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - InCharge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizing film. i)natural White j)Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both endsof vertical member restrained but panels within 0.9 sq.m.)Top,bottom & side member 65 Intermediate member. 66 Glazing clip. 67 Supplying heavy duty hydraulic double action floor spring along with toppin/set of pivots conforming to IS: 6315 or any approved make as perdirection of Engineer in charge. 68 Supplying heavy duty top pin/set of pivots of local make and approved by the Engineer-in-charge. (This item to be provided where floor spring not 69 Supplying concealed type heavy duty PVC headed aluminium tower boltfor double leaf doors as per approved make and brand as per direction ofEngineer-in-Charge.250 long 70 Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge.(weatger gasket/woolpile) 71 Filling the gap in between aluminium frame & adjacent RCC / Brick/ Stone work by providing weather silicon sealant over 6mm dia backer rod of approved quality as per architectural drawings and direction of Engineer-in-Charge complete. Upto 5 mm depth and 5 mm width 72 Extra for each additional floor. 73 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including, rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface including threading nosing and drip course where necessary.i) With 1:6 cement mortar.a) 20 mm thick plaster.in ground floor 74 a.2) In first floor 75 15 mm th.b.1) In ground floor. 76 b.2) In first floor 77 ii) With 1:4 cement mortar.c) 10 mm thick plaster.c.1) In ground floor 78 Neat cement punning about 1.5mm. thick in wall, dado, window sills, floor, drain etc. 79 Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) 80 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)i) Standard Quality 81 Applying Exterior grade Acrylic Primer of approved quality and brand on plastered or concretesurface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior Immersion paint including scrapping and preparing the surface thoroughly, complete as per manufacturers specification and as per direction of E.I.C(i)One coat in ground floor 82 2) In first floor 83 Protective and decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required.The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.b) NORMAL Acrylic Emulsionin ground floor(two coat) 84 2) In first floor(Two coat) 85 Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. 86 a ) Priming one coat on timber or plastered or surface with synthetic oil bound primer of approved quality including smooth ening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 87 b ) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint.) 88 (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary.(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) 89 (b) On steel or other metal surface :--------With super gloss (hi-gloss) ------(iv) Two coats (with any shade except white) 90 (iii) One coat (with any shade except white) 91 Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (i) 3 mm thick (weighing 7.4 kg/Sq.m) 92 (ii) 4 mm thick 93 Renewing worn out putty of glass panes :(a) Panes not exceeding 0.2 Sq.m 94 Supply fitting approved type ventilator in position after cutting holes in walls setting in cement mortar, mending damages to wall and plaster and two costs of point of approved brand and shade.(b) R.C.C ventilator of 20 mm. thicki) Upto 0.10 Sqm. Area 95 Artificial stone in floor, dado, staircase etc with cement concrete(1:2:4) with stone chips, laid in panels as directed with toppingmade with ordinary or white cement In ground floor. (as necessary) and marble3 mm. thick topping (High polishing grinding on this item is notpermitted with ordinary cement).(ii) 25 mm th.(i) Ground floor 96 Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wallafter unscrewing bolts, nuts, screws etc.andstacking the material at site as directed. 97 Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work)(GCI sheet to be supplied by contractor)(i) In Roof:-b) With 0.60 mm thick sheet 98 (ii) In wall:-a) With 0.60 mm thick sheet 99 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 100 (f) 25 mm to 30 mm shuttering without staging in foundation 101 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (SpunYarn,Valamoi/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. 102 B) UPVC Fittings:a) Plain Tee(ii) 110 mm. Dia 103 b) Plain Y(ii) 110 mm. Dia 104 c) Bend 87.5 degree (ii) 110 mm. Dia 105 d) Shoe c(ii) 110 mm. Dia. 106 Uprooting and removing plants from the surface of wallsparapet etc and making good damages. (Repairing ofdamages to be paid separately) 107 Renewing throating,nosing or drip course moulding with 15 mm.thick cement plaster (1:4) complete. (Cement 0.7Kg/Mtr.)In ground floor. 108 Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in- Charge prior to execution will be necessary).(Payment to be made on area cleared) 109 Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union cross, elbow nipple, long screw reducting socket reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground (payment will be made on the center line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials) FOR EXPOSED WORK15MM DIA MEDIUM QUALITY 110 ii) 20 mm dia medium quality 111 ii) 25 mm dia medium quality 112 Chromium plated round shower with revolving joint (Equivalent toCode No. 541(N) & Model - Tropical / Sumthing Special of ESSCO orsimilar brand). 113 Supplying, fitting and fixingpillar cock ofapproved make---CP pillar cock-15mm(Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand) 114 Supplying, fitting, fixing G.M wheel valve of approved brand and made tested to 21 Kg. Per sq. cm. (for water lines only.) --- i)20mm. 115 ii)25mm 116 11)40mm 117 Supplying fitting fixing bib cock Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar brand). 118 b)i.Chromium plated Stop cock [Equivalent to Code No.513(A) & 513(B) & Model - Tropical/Sumthing of ESSCO or similar brand] 119 Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver redas per I.S. 3438 / 1965 together with brass C.P. hinges.(i) 450 mm X 300 mm 120 Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. b) With S trap (with vent) 121 Supplying, fitting and fixing towel rail with two brackets.a) C.P. over brass.b) I) 25 mm dia and 450 mm long 122 Supplying, fitting and fixing 18 mm. thick marble partition slab with chawk doongri marble square cut, both sides polished with two front corners rounded and edges polished. 123 Supplying, fitting and fixing white vitreous china best quality approvedmake wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillarcock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approvedquality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approvedquality P.V.C. connection pipe with heavy brass C.P. nut includingmending good all damages and painting the brackets with two coats ofapproved paint.(i) 450 mm X 300 mm size 124 Supplying, fitting and fixing Orissa pattern water closet in white glazedvitreous chinaware of approved make in position complete excluding P orS trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm each 125 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. Specification withP.V.C fitting complete, C.I. brackets including two coats of painting to bracket etc. 126 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecessary fixing materials and clamps complete.i) Polythene Flush Pipe 127 Flat back urinal (half-stallin urinal)in white vitreous china ware of approved make (CERA/HINDWARE)supplied,fitted and fixed in position with brass screw on75mmx75mmx75mm wooden block complete. (i) 635 mm X 395 mm X 420 mm each 128 Supplying ,fitting and fixing approved brand p.v.c. connector white flexible ,with both ends coupling with heavy brass C.P.nut 15mm dia.(i) 300 mm long 129 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.900 mm long 130 Approved patent vent cowl I.C.I. conforming to I.S.S.a) 75 mm dia. 131 Supplying PVC water storage tank approved quality with closed top with lid (block). Multilayer. a) 1500 Litre capacity. 132 Labour for dismantling (i) 15 mm 133 (ii) 20 mm 134 100 mm 135 Refixing GI pipe with fittings with cleaning wher necessary(i) 15 mm 136 (ii) 20 mm 137 Removing chokage in G.I pipe including cleaning pipe(i) 15 mm 138 (ii) 20 mm 139 Renewing C.I. clamp for pipe including cutting hole in wall etc. and mending good all damages with cement concrete(4:2:1) with jhama chips and cement plaster (6:1) to match with and curing.15mm 140 (ii) 20 mm 141 Dismantling wash basin with brackets with or without waste fittings. 142 Dismantling E.P. or Anglo-Indian W.C. 143 Dismantling urinal. 144 Dismantling pillar cock of wash basin. 145 Cleaning glazed tiles with acid 146 Mazdoor 147 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings asrequired,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separatepayment will be made for accesories, specials. Payment for painting willbe made seperately)(a) For Exposed Work PVC Pipes 15mm 148 20 mm metredia 149 25 mm metredia 150 40 mm metredia 151 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm 152 Supplying, fitting and fixing 15 mm swan neck tap with left & right handoperating nob with aerator (Equivalent to Code No. 510, 510(A) andModel - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand 153 Iron door ring of approved quality fitted and fixed with nut and washer complete. (i) 50mm dia. 154 Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) 155 ii) Godrej Hydraulic door closer fitted and fixed complete.(c) Light type 156 Filling in foundation or plinth by fine sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) 157 Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.(a) Upto 20 users:-(ii) Beyond a lead of 150 metre and outside the Municipal limit 158 Cleaning rubbish, sludge, weeds scum, liquid earth, mud etc.etc.from road side masonary drain/ hume pipe drain/ culvert etc. by mathor labour after removing concrete.Slab/manhole cover etc.without damaging the same and refixing the same properly after cleaning as necessary and removing the sludge etc.etc.by using iron pans,buckets including all labour, tools & plants including removing the spoils in dry condition and disposing the same by truck beyond the road side in conformity with municipal/corporation rules for such disposal including loading into truck and cleaning the road side in all respects as per direction of the Engineerin-Charge. 159 Renewing profile of rolling shutter including fitting fixing complete as per existing size and shape 160 Labour for taking out rolling shutter (only shutter portion) dismantling by parts for repair or (replacement of damaged parts only), rehanging and refitting the same in position after necessary repairs (excluding the cost of supply of new parts 161 Easing and oiling, cleaning collapsible gate and repairing to locking arrangements. 162 Easing and oiling, cleaning rolling shutters excluding repair to inside locks 163 Easing and oiling W.I. Gate or G.I. Gate. 164 Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L. 165 Extra for each additional story 166 Labour for lowering plastic water storage tank and stacking in places asdirected.(i) Upto 1500 litre capacity 167 (b) Extra for each additional story 168 Labour for punching hole in plastic water storage tank upto 50 mm dia 169 Labour for taking out (from fencing) line of wire (galvanised,strand or barbed) by drawing the same out through holes in thebody of the post or through holes formed by fixed staples.(Payment to be made on the length of the wire taken out.) 170 ) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line ofbarbed wire in fencing (holes already made in the body of the post)or fixed by staples tightening and fixing the wires in taut conditionwith straining bolts including the cost of cutting and of lappingjoints in the wire as necessary but excluding the cost of galvanisedstaples,straining bolt and binding wire where necessary. 171 Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete. (i) 10 mm. dia. (a) 150 mm 172 Supplying galvanised staples fitted and fixed complete. (a) 19 mm. to 25 mm. size
Contract Date: Jun 23, 2026 Contract Value : 5.85 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
16.
Educational and Research Institute #11326523 Technical Bid
Tender For Purchase Of Non-Consumables For Physics Lab In Basic Engineering (First Year) Department = Limited- 2 Joule Calorimeter - Copper Vessel, Battery Eliminator 3A, (2,4,6,8,10,12 V), Tubular Rheostat 20-3.3A, One Way Plug Key, Analog Type Dc Ammeter (0 2A), Voltmeter (0-5V), Thermometer (Alcohol), Stop Clock 3 Ic Regulated Battery Eliminator- Ic Regulated, Input: 230V Ac; Output: 0-12V Dc In Steps Of 2V; Capacity: 1A Or 2A. 4 Galvanometer- Moving Coil Type, 30-0-30 Scale, Unbranded With Bhel Specification-Sensitivity 0.143Mm/V 5 Voltmeter- Dc Voltmeter; Range 0–10 V, Analog 6 Ammeter- Dc (0 - 2 Amp) 7 Parallelogram Apparatus- Parallelogram Law Of Forces Apparatus Fitted With Stand 8 Decade Resistance Box- Resistance Box 12 Month Warranty (Dial Type) -Manganin Coil- 2 Dials 9 Sonometer Apparatus- Sonometer With Meter Scale Attached Along With Knife Edge, Tuning Forks Set 256, 384, 512 Ranges, Hammer, Slotted Weight - 500 Gm Each To A Total Of 3 Kg. Brass Wire (5 M) 10 Travelling Microscope- Branded Travelling Microscope 0 200 Mm Horizontal And 0-150 Mm Vertical Measurement 11 Potentiometer - It Features A 1-Meter To 10-Meter Constantan/Manganin Wire Stretched On A Wooden Or Sunmica Baseboard With A Millimeter Scale. It Includes 4Mm Brass Terminals, A Pencil Jockey For Contact, Wire Options (10 Wires), And A Typical Resistance Range Of 10-20 Ohms, Ideal For High-Precision Voltage Measurements. 12 Viscosity Apparatus – StokeS Apparatus With Metre Scale Attached And Long Cylindrical Glass Jar, Glass Beads Small Size (1 Box), Screw Gauge (0-15 Mm) 13 Rheostat - High-Grade Ceramic Tube, Oxidized Resistance Wire, 0.5A 5A, Range 10Ω–100Ω. 14 Deflection Magnetometer Apparatus - Deflection Magnetometer Apparatus With Compass Box And Two Short Bar Magnets 15 Solar Cell Kit- The Apparatus Consist Of Variable Dc Power Supply, Led, Solar Cell And Two Multimeters (Or An Ammeter And A Voltmeter). A Variable Dc Power Supply Of 0 5V. Light Source Is Provided By Led. The Illumination Intensity Of The Led Can Be Controlled 16 Wheatstone Bridge Kit- Series Arm: Four Decade Dials In Steps Of Thousands, Hundreds, Tens, & Units Of OhmS. Ratio Arm: The Ratio Arm Of The Bridge Is Capable Of Selecting Multiplying Factor Of 0.001, 0.01, 0.1, 1, 10, 100, 1000 For Resistance Measurements. Two Press Keys Are Provided, One Marked B Is For Battery & One Marked G Is For Galvanometer One Toggle Switch Is Provided For Internal Battery A Sensitive Galvanometer Is Provided In The Bridge. 17 OhmS Law Verification Kit- Battery Eliminator-3A, (2,4,6,8,10,12 V), Tubular Rheostat 20-3.3A, One Way Plug Key, Analog Type Dc Ammeter (0-2A), Voltmeter (0-5V), Standard Resistance Coil Of 1, 2 Ohm (2-Set) Wound On A Wooden Bobbin 18 Boyle’S Law Apparatus - The Apparatus Includes The Quill Tube, A Retort Stand, A Clamp, And A Mounted Meter Scale. Quill Tube Specifications: Length: Approximately 50 Cm. Bore Diameter: Uniform Bore, Roughly 1 Mm To 2 Mm. Construction: Glass Tube With One End Sealed. Trapped Substance: A Mercury Pellet (Or Thread) Of Length 10 To 15 Cm Is Introduced To Enclose A Column Of Air. Mounting: Attached To A Half-Meter Or Meter Scale. 19 Torsional Pendulum - Torsional Pendulum Metallic Disc, Symmetrical Masses And Pendulum Stand, Steel Wire 20 Compound Bar Pendulum- One Meter Long Iron Strip Well Painted With Holes At A Distance Of Every 5 Cm And Also With Pair Of Brackets And A Heavy Base Table Top Stand With Stop Clock 21 Helical Spring Apparatus-- Structure: A Rigid Support Mounted On A Heavy Metal Base, Typically Cast Iron, To Ensure Stability During Tests. Springs: High-Tensile Steel Spiral Springs, Typically (Approx 25 Mm) Diameter, (100 Mm) Long. Measurement Scale: A Vertical Steel Meter Scale, Usually With (1Mm) Graduations, For Precise Deflection Measurement. Loading Mechanism: A, Typically (50G), Hook-Attached Weight Hanger At The Bottom.Pointer: A Fine Pointer Attached To The Bottom Of The Spring Moves Along The Scale. Accessories: Includes A Set Of Slotted Weights (E.G., (6Times 50G) Or Similar Sets) For Incremental Loading.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
17.
Public Administrative Department #11325415 AOC
Tender For Maintenance Of Municipality Abcd Blocks-General Civil Work; 1 MUNICIPAL OFFICE A&B BLOCK 2 OD429488/2023-2024:Labour engaged for cleaning surrounding area 3 OD429932/2023-2024:Cleaning the tiled surface and removing dirt, dust , bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agentEngineer - incharge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building / structure, all as per direction of Engineer- in- Charge ( The rate is inclusive of all materials & labours involved except scaffolding). 4 14.76:Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. 5 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 6 50.18.9.11.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 15 mm dia 10 Kgf/cm2- External work - Exposed on wall 7 9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 8 9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. 9 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 10 21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 11 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 12 9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 13 OD334510/2025-2026:200mm wide uPVC square rain water gutter,UPVC qutter clamp,UPVC end cap,joints etc 14 OD334511/2025-2026:Providing and fixing steel bib cock of approved quantity conforming to IS: 8931 15 OD334512/2025-2026:Supplying and fixing 75mm dia PVC pipe for the down water (4kg/cm2) 16 OD334513/2025-2026: Providing and fixing factory made PVC door including cost of all fittings, labour charges etc complete (Approved Data of CE LSGD vide circular dated 18.08.2016) OD-11,DSR 2016 1.4902 dtd 05.06.2017 17 11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 18 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 19 50.9.11.2:Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately)as per the direction of site Engineer-in-charge. Please Enable Macros to View BoQ information
Contract Date: Jun 22, 2026 Contract Value : 4.23 Lakh
Government Departments No of Bidders 1
18.
Rural Development #11325109 AOC
Tender for Empanelment Of Vendors For Specified Fine Sand For Mortar / Concrete/ Brick Work And Local Sand For Trench / Plinth Filling For Various Worksites Under Bokafa Rd Block Under South Tripura District. , Item Wise Boq Boq_Ver3.0 Item Wise Normal Inr Only Inr Select, Excess (+), Less (-) Tender Inviting Authority: Executive Engineer, Rd Santirbazar Division Name Of Work: Empanelment Of Vendors For Specified Fine Sand For Mortar / Concrete/ Brick Work And Local Sand For Trench / Plinth Filling For Various Worksites Under Bokafa Rd Block Under South Tripura District. Dnit No: E-Dt-153/Sand(Bkf)/Ee/Rd/Stb/2025-26 Dt. 05/03/2026 (3Rd Call) Name Of The Bidder/ Bidding Firm / Company : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Bidder Must Quote Single Rate Against Each Item Otherwise All The Rates, Quoted Against That Particular Item, Will Be Rejected. Quoted Rate Per Cum Incl. All Taxes & Charges, (Gst, It, Forest Royalty, Carrying, Loading, Unloading, Stacking, Counting Charges Etc.) To Deliver In Any Worksite Of The Area (Rs.) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Name Of Item Item Code / Make Tentative Quantity Units Estimated Rate In Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Quoted Rate Jirania Rd Block And Jirania Nagar Panchayat Mandwi Rd Block Old Agartala Rd Block And Ranirbazar Municipal Council Belbari Rd Block annual maintenance contract annual maintenance contract Mohanpur Rd Block And Mohanpur Municipal Council Bamutia Rd Block Dukli Rd Block Hezamara Rd Block Lefunga Rd Block Total Amount Without Taxes In Rs. P Total Amount With Taxes In Rs. P Total Amount In Words , Fine Sand (For Mortar / Concrete/ Brick Work) Under Bokafa Rd Block Area. , Local Sand (For Trench / Plinth Filling) Under Bokafa Rd Block Area. , Fabrication Charge Including Fitting & Fixing Of The Finished Product In The Worksite Charge Of Any Structure. Rates Should Be Incl. Cost Of Base Plate, Cleat. (Pipe/Angle/ Holding Down Bolt Will Be Issued From Department). , Manufacturing & Supplying Including Fitting & Fixing Of The Finished Product In The Worksite Of Fabricated Steel Tubular Truss Of Spacing 3.09M C/C With All Accessories Such As Required Purlin, Bottom Runner, Bracing, Trusses, Cleat, Base Plate & Other Fittings Of Trusses & Projection Of Rafter & Purlin To Gravel Wall Etc Complete (Only Cost Of Holding Down Bolt / Nut Bolt Will Be Borne By The Department) Span-(Up To 9 M) , Manufacturing & Supplying Including Fitting & Fixing Of The Finished Product In The Worksite Of Fabricated Steel Tubular Truss Of Spacing 3.09M C/C With All Accessories Such As Required Purlin, Bottom Runner, Bracing, Trusses, Cleat, Base Plate & Other Fittings Of Trusses & Projection Of Rafter & Purlin To Gravel Wall Etc Complete (Only Cost Of Holding Down Bolt / Nut Bolt Will Be Borne By The Department) Span-(Above 9M) , Manufacturing, Supplying Including Fitting & Fixing Of The Finished Product In The Worksite Of Complete M.S. Rolling Shutter Made Of 80 X 1.35 Mm Ms Laths Interlocked Together Through Their Entire Length & Joined Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets Side Guides & Arrangement For Inside & Outside Locking Push & Pull Operation Complete But Incl. Fixing Of The Top Cover, Ball Bearing & Spring Etc. , 100 X 100X 8 Mm - Ms Angle , 65 X 65 X 8 Mm - Ms Angle , 50 X 50X 5 Mm- Ms Angle , Manufacturing & Supplying Of Complete Steel Door As Per Jail Specification (Specification Is Enclosed). , Manufacturing & Supplying Of Complete Steel Window As Per Jail Specification (Specification Is Enclosed) , Fabrication / Repairing Charge Of Old Grill & Other Steel Item. , Fabrication/Repairing Charge Of Old Rolling Shutter, Collapsible Gate Etc. , Manufacturing & Supplying Of Ms Grill Incl. Arrow For Boundary Wall As Per Reqd. Design & Specification , Manufacturing, Supplying Incl. Fabrication Of Minor Shed For Any Output Unit, Stand (Base) For Water Tank, Sign Board And Other Minor Structure (No Materials Will Be Issued From Department) , Ms Hard Drawn Steel Wire Fabric (75X25mm Mesh Weight Not Less Than 7.75 Kg/ Sqm). , Manufacturing & Supplying Of Complete M.S. Ornamental Grill With Square Bar Of Size 20Mm / 25 Mm. , Manufacturing & Supplying Of Complete Steel Window Made With M.S. Ornamental Grill With Square Bar Of Size 20 / 25 Mm Including Shutter Frame But Excluding Shutter. , Manufacturing And Supplying Of Ms Chain Link (Made Of Gi Wire, 100 Mm X 100 Mm , 8 G) , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply , Water Supply Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select % 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Jun 22, 2026 Contract Value : 694
Government Departments No of Bidders 2
19.
Heavy Industries and Public Enterprises #11321092 Technical Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Barpeta, Assam- 1 Civil Works 2 Solid Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 3 12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 4 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 5 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 6 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 7 Providing And Laying Premiumvitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier,Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Size Of Tile 600 X 1200 Mm 8 Providing And Laying Premium Vitrified Wall Tile In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600 X 1200 Mm 9 Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 10 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 11 Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is : 14856, Complete As Per Direction Of Engineer- In-Charge. 12 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 13 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 14 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 15 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm,With Swan Neck Faucet With Pipe In Let And Drain Provision, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510X1040 Mm Bowl Depth 250 Mm 16 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms 17 Providing And Fixing Cp Towel Rod Complete Fixed With Cp Brass Screws Of Approved Quality Of Minimum 600Mm Length Approved As Per The Requirement Of Engineer In Charge. 18 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: 45 Cm Length15 Mm Nominal Bore 19 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 40 Mm Dia 20 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 21 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 10Kgf/Cm2 22 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work,Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf/Cm2 23 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall 24 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall 25 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 26 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75X75X75 Mm Dia Door Tee 27 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Bend 28 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 29 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes,Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 30 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 31 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 32 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X110 Mm Dia Door Tee 33 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 34 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall 35 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Partition Of Approved Brand And Manufacture, Including Top & Bottom Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Fittings, All Complete As Per Direction Of Engineer-In-Charge. 36 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately) 37 Providing And Fixing Ss H Handle Having Min 45 Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete. 38 Providing And Fixing 3M Fasara Frosted Etching Film Of Thickness 25 Microns Self- Adhesive Of Approved Colour, Shade, And Quality With Cutting As Per Approved Design And Pattern, Including Cleaning Of Glass And Making Surface Smooth For Fixing Of Film To The Surface, All Completed As Per The Direction Of The Engineer In Charge. 39 Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete 40 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 41 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 42 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides 43 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 44 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/ Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete,Complying To Astm C920, Din 18540-F & Iso 11600Upto 5 Mm Depth And 5 Mm Width 45 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 46 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 47 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In- Charge. 48 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 49 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 50 Vinyl Transparent Vision Glass Stickers: Supply And Pasting Of Vinyl Transparent Vision Glass Stickers In Approved Size And Design In Glass Partition And Door As Per The Instruction Of Engineer In Charge. 51 Backlit Acrilic Board With Projected Letters: Supply, Installation, Testing And Over Suitable Welded And Painted 25X25X3Mm Ms Angle Frame In Suitable Location And In Proper Line And Level With All Necessary Fastners, Supports Etc. Electrical Works Likes Electrical Wirings, Connections, Fittings, Externaly Fixed Weather Proof 2/3 Pin Plug Points And Sockets Including Boxes Etc. To Be Complete Properly. All Fabrication And Fixing Should Be Done As Per Approved Design And Instructions Of Engineer In Charge. (Note: Only Front Elevation Will Be Measured.) 52 Furniture 53 Supply And Erection Of Airport Type 3 Seater Waiting Chair With Powder Coated Chromium Finish Having Minimum Dimensions 1675Mm Length X 710Mm Width X 775Mm Total Height And 400Mm Seat Height . Seat: High Quality Cold Rolled 1.2Mm Thick Steel Perforated Sheet Pressed And Welded To Form The Shape. Arm & Leg: High Quality 1.2Mm Thick Ms Tube / Sheet . Cross Bar: High Quality Cold Rolled 2Mm Thick Steel Sheet Pressed And Welded To Form The Shape. 54 Supply Of Phlebotomy Chair With Optimum Design Made Up Of Ms Power Coated Frame And Up Upholstery Type Seat,Back Rest And Arm Rests.Both Side Arm Rest Should Be With Height And Position Adjustable System And All As Per The Instruction Of Engineer In Charge. 55 L-Type Workstation Of Overall Size (1350 * 600)Mm + (1000 * 450)Mm X 750 Mm (L X D X H) And Pedestal Unit Made Up Of 18 Mm Thick Exterior Grade-I Mdf Board On All Sides Conforming To Is:14587 From Approved Makes Such As Century/Greenply/Fineply Or Equivalent With Decorative Laminate On Both Side And All Edges To Be Fixed With 2Mm Thick Pvc Edge Beading. One Three-Drawer Modular Pedestal Unit Of Minimum Size 450 Mm (W) X 500 Mm (D) X 650 Mm (H) All With Retractable Key Board Tray, Drawer Channels, Hinges, Handles, Individual Locking System, And All Necessary Fittings And The Workstation Should Have An Electrical Flip Box With 2 Nos Universal Power Socket & 1 No Data Socket Etc And Cable Management Tray. All Work As Per The Approved Design And Instruction Of The Engineer-In-Charge/Architect. 56 Providing And Erection Of Reception Counter Table Of Length 1200 Mm And First Level Should Be Provided At A Height Of 750 Mm And Width 600 Mm And The Second Level At A Height Of 1050Mm From Base With A Width Of 300. The Table Made Of 18Mm Thick Pre Laminated Medium Density Board Of Exterior Grade (Grade I) Is: 14587:1998 With Decorative Laminated Finish On Both Sides And 2 Mm Thick Pvc Beading On All Edges, Including Electrical Flip Box, Cable Measurement Tray, Grommets With 3 Nos Universal Power Socket And Ethernet Port, Three Drawer Pedestal Unit With Drawer Channel, Handles, Hinges, Lock All Complete As Per Approved Drawing And Installation Of Engineer In Charge/Architect. 57 Supply And Installation Of Visitors Chair Medium Back, Mesh Back Cushion Seat With Fixed Supports Made Of 304 Stainless Steel/ Powder Coated Ms Of Approved Colour Or Shade As Per The Instruction Of The Engineer In Charge 58 Revolving Chair: Medium Back Ergonomic Chair With Five Nos. Star Shaped Nylon Base. Castor: 50Mm Diameter Nylon Twin Wheel, Gas Lift Height Adjustment, Back Angle Adjustment , Fixed Armrest Providing Natural Resting For Arms. Seat With Pu Coated Foam Backed Fabric, Back Rest With Mesh Type Fabric, Upholstery: Heavy Duty Rubber Backed Fabric In Black 59 Counter Height Stools :Supply And Erection Of Counter Height Stools ( Bar Stools ) Of Following Specifications : Revolving Adjustable Chrome Plated Steel Body Chairs With Resistance To The Corrosion. Cushion Seat With Lift Mechanism For Adjustment Of Height. Minimum Height 750Mm Before Expansion. Medium Back Rest And Arm Rest. Item Shall Be Of Reputed Make. 60 Supplying And Fixing Of Lab Work Table With 18 Mm Thick Edge Moulded Granite Top Supported Over 18Mm Thick Marine Ply Wood Of 2500Mm,L X 1200Mm,W X 850Mm, H And Powder Coated Gi Frame Of Section Size Not Less Than 50X50X1.5 Mm Including And Providing 4 Nos Under Storage Movable Cabinents Of Size 600Mm,L X 450Mm,D X 750 Mm,H And Powder Coated Steel Sheet Of Thickness Not Less Than 1Mm With 1 Drawer And Partition Bottom Storage Space With Door Including Drawer Channels, Individual Locks And Handles All As Per The Approved Drawing And Instructions Of Engineer In Charge 61 Lab Work Bench -The Work Bench Top Made Up Of 18Mm Thick Granite Top Edge Moulded Over 18 Mm Thick Marine Plywood And Gi Powder Coated Frame Work Of Section Size Not Less Than 50X50X1.5Mm. The Width Of The Table Shall Be 750Mm And Height Shall Be 850Mm. The Frame Provided With Level Adjusting Screws Fixing Accessories ,Carriage Of Material All Complete As Per The Approved Drawings And Direction Of Engineer In Charge.Note Only Length Of The Table Shall Be Measured For Making Payment. 62 Cabinet/Wardrobe: Providing And Errection Of Cabinet/Wardrobe Unit Made With 18 Mm Thick Prelaminated Mdf Board Of One Side Decorative Lamination And Other Side Balancing Lamination Having Total Unit Dimension Of 900Mm,L X 450Mm,Dx 2400Mm,H And All Edges To Be Sealed With Pvc Edge Beeding Of 2.00 Mm Thick Including All Fittings Such As Autoclose Hinges,Chromium Plated Brass Individual Locks & Handles ,Tower Bolts Etc All Required. All Shelves To Be Fix With Proper Support And Bracket Holders At A Spacing Of 400 Mm Centre To Centre And All As Per The Drawings And Instruction Of Engineer In Charge. Board Make : Greenlam/ Merino / Century/ Equivalent . Only Front Elevation Will Be Measured. 63 Overhead Storage: - Providing And Fixing Overhead Storage Unit With Minimum 18 Mm Thick Pre-Laminated Medium Density Fiber Board Exterior Grade (Grade-I) Is: 14587:1998 Marked With One Side Decorative And Other Side Balancing Lamination. Cupboard Shutters Edge To Be Sealed With Pvc Edge Bending Tape 2.00 Mm Thick Of Approved Brand Including Isi Marked Nickel Plated Bright Finishing M.S. Piano Hinges Conforming To Is:3818 Marked With Fixing Chromium Plated Brass 50 Mm Cupboard Or Wardrobe Knobs, Special Quality Chromium Plated Brass Cupboard Locks With Six Levers Of Approved Quality Including Necessary Screws Etc. Complete. Only Front Elevation Will Be Measured. 64 Electrical- Wiring 65 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 66 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 67 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 68 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 69 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire 70 Fixtures 71 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socketoutlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Beused In Non Residential Buildings) 72 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Ampsmodular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required 73 Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front Onsurface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25A Modular Sp Mcb, C Curve Including Connections, Painting Etc. Asrequired. 74 Supply, Installation Of Surface Mounted Led Tubelight. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification. Luminaire Shall Be Designed To Emit At Least 3600Nominal Lumens And Efficacy Of Atleast 105 Lumen/Watt And Minimum System Wattageof 30 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Upto 30% Over 25K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. Make - Philips, Crompton, Wipro, Havells 75 Supply And Installation Of Surface/Recess Mounted Led Round/Square Luminaire With Crca Housing Suitable With Fully Diffused Diffuser For General Lighting In Offic Eareas. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K, Cool White Light. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification.Luminaire Shall Be Designed To Emit At Least 1000 Nominal Lumens And Efficacy Ofatleast 105 Lumen/Watt And Minimum System Wattage Of 10 -15 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Up To 30% Over 50K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. For Light Fittings To Be Installed In False Ceiling, All Required Cuttings Shall Be Made And Damages Shall Be Made Good As Per The Direction Of Engineer In Charge. Make-Philips, Crompton, Wipro 76 Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep - 5 Star Rated, 3 Blade Ceiling Fan Complete With 300Mm Down Rod, Canopies,Shackles. 77 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existingmodular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 78 Supplying, Conveyance And Installation Of 3 Blade, 400 Mm Sweep, 1400 Rpm Wall Mount Fan Including Frames And All Mounting Accessories Complete. Recommended Make: Usha/ Havells/ Bajaj / Almonard Or Equivalent 79 Supplying, Conveyance And Installation Of 150 Mm Sweep,1800 Rpm Exhaust Fanincluding Frames And Allmounting Accessories Complete. Recommended Make: Usha/Havells/Bajaj Or Equivalent 80 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. 81 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. 82 Supply, Installation Of 12 Watt Led Bulb. 83 Db And Switchgear 84 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) 85 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door 86 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 87 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 88 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 89 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existingmcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63Amps 90 Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30Milli Amperes In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required.63 Amps 91 Supplying And Fixing Cable End Boxes (Ip 43) Suitable For Following Single Poleand Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess,Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Spn Mcbdb 92 Cctv And Networking 93 Supply, Conveyance And Installing Of 2Mp Ip Dome/Bullet Camera Having 1/3Progressive Scan True Day And Night Colour Ir Camera Having Effective Pixel Of 2Mp, Video Frame Rate Of 2Mp @30Fps, Minimum Illumination Of 0.01 [email protected], 0Lux@Ir On, 20 M Ir Range, 24 Ir Led, Awb, Agc, Blc, 2D Noise Reduction,With 3.6Mm Board Lense, 12 Vdc, Poe Ip67 Rated Weatherproof Performance. 1 Year Warranty. Make: Bosch/Cp Plus/Honeywell Or Equivalent 94 Supply, Installation And Integration Of 8 Channel Embedded Linux Poe, Nvr (Network Video Recorder), Having Dual Core Embedded Processor, Must Connect 8 Channel Ip Cameras , Should Support Min 2 Sata Hdd Each Of 6Tb And Must Recordvideo Simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smartevent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(Hevc)/H.264+/H.264, 2 Year Warranty, Image Quality Should Be Maintainedthroughout The Warranty Period. Make: Bosch/Cp Plus/Honeywell Or Equivalent 95 Supply And Installation Of Network Switch. 8 Port Poe Switch 1000Base-T Copper Ethernet Poe+ Connections, 10M/100M/1G Rj-45 Copper Ports, 1000Base-X Fiber Sfp Ports, 8 Port Auto Sensing 10/100/1000 Mbps Poe, Minimum Cpu Memory 512 Mb With 2 Sfp/Combo Ports, Energy Efficient Ethernet (Ieee 802.3Az). Make: Cisco/Cp Plus/ Netgear Or Equivalent 96 Supply And Fixing Of 6U Wall Mounting Rack With Supply And Fixing Of Mounting Brackets For Support Lockable Front Door And Detachable Side Doors, Cable Manager And Pdu Of 4 Or 6 Sockets Including Cooling Fan With Accessories Complete 97 Supply And Installation Of 8Tb Hard Disk 98 Supply And Installation Of Led Color Monitor Of Minimum 32 Inch Screen, Complete,Uhd Display Make: Lg/Samsung/Panasonic Or Equivalent. 99 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable 100 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 101 Supplying And Fixing Rj45 Outlet Including Cover Plate, Keystone Jack And Gang Box Supporting, Connection Etc. As Required 102 Air Conditioning System 103 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Followingcapacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Single Phase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 2 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 104 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Following Capacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Singlephase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4 M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 1.5 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 105 Supply And Installation Of Additional Copper Piping, Cabling From Indoor To Outdoor And Drain Piping For Air Conditioning Unit With Proper Insulation Including All Required On Wall/Above False Ceiling Complete 106 Supply, Installation, Testing And Commissioning Of True On-Line Double Conversion 6 Kva Ups System With 1:1 Crest Factor Single Phase Phase Input – Singlephase Output. Inversion Shall Be Microprocessor Controlled With Instantaneous Sine Wave Control Using Igbt. Ups Shall Have Standard Display Features, Alarms, Safeties, Etc Input Voltage Range : A) Phase & Single Phase With Ground B)Votage Range 190 Vac & 250 Vac C)Input Frequency : 50/60 Hz D)Power Factor : 0.95 Or Above E)Thd : Less Than 5% With Full Load Bypass F) Voltage Range & 200Vac & 240 Vac G) Frequency Range – 45-55 Hz/55-65 Hz Output Voltage Range H)Voltage Range & 200Vac & 240 Vac I)Frequency Range & 50/60 Hz J)Voltage Distortion & Linear Load = 2% K)Voltage Distortion – Nonlinear Load = 5% L)Output Waveform – Pure Sinewave M) Minimum Back Up Time : Continuous 60 Minutes At Full Load Rectifier Shall Be Full Wave Type (Shall Fully Meet The Specified Input Power Requirements) Battery Type: Sealed Lead Acid Maintenance Free Dc Voltage : 24/48/96V Dc System, Battery Nos And Capacity Shall Be Designed For Optimum Storage Space. Make: Liebert Vertiv/Apc By Schneider/Numeric By Legrand 107 Visi Cooler And Refrigerator 108 Supply And Installation Of 260 Litre Refrigerator, Direct-Cool Model With A Minimum 3-Star Bee Rating And Stabilizer-Free Operation. It Shall Use Eco-Friendly Refrigerant (R600A) And Have A High-Efficiency, Low-Noise Compressor. The Unit Shall Include Toughened Glass Shelves, A Vegetable Crisper, Bottle Storage For 2L Bottles, An Internal Freezer Compartment, And A Removable Anti-Bacterial Gasket. It Shall Operate On 230V, 50Hz Ac And Include Standard Accessories Such As An Ice Tray And Egg Tray. The Refrigerator Shall Have 1-Year Comprehensive Warranty And 10-Year Compressor Warranty, With Bis Certification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
21.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
22.
Public Administrative Department #11300743 AOC
Tender For Lac-Ads-Lac Ads 2025-26 Sri. T P Ramakrishnan Mla - Tm Balakurupp Grandhalayam Manava(Avala) Cheruvannur Pt-Perambra Constituency-General Civil Work- 1 Building cocstruction 2 2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 4 51.2.3:Filling with Quarry Muck
Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade 5 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 6 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 7 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 8 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 9 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 10 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 11 50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. 12 2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 13 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 14 5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 15 5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 16 5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 17 5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). 18 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 19 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 20 50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 21 OD410732/2025-2026:Supplying fabricating PVC door with frame in locally available best quality including cost of all fittings, labour charges etc.complete. 22 50.6.1.8:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete 23 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 24 13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 25 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 26 13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) 27 13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 28 10.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 29 21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 30 21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 31 21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) 32 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 34 17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 35 50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 36 17.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 37 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 38 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 39 51.19.ST2:Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)
2. 15 to below 25 flush capacity 40 50.18.9.13.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall 41 50.18.9.14.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall 42 50.18.9.7.2:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 43 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 44 50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl 45 50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 46 50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 47 50.18.9.20.3:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow 48 50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 49 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow 50 50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow 51 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 52 50.17.1.1:Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 53 50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 54 18.15.1:Providing and fixing brass bib cock of approved quality :15 mm nominal bore 55 18.58.1.1:Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia Please Enable Macros to View BoQ information
Contract Date: Jun 17, 2026 Contract Value : 24.12 Lakh
Government Departments No of Bidders 2
23.
Public Administrative Department #11300261 AOC
Tender For Annual Plan-161/25-GREENVALLY DWSSBORE WELLWARD-6-General Civil Work--- 1 Dws- 2 OD496514/2024-2025:Drilling charge of 110 mm bore well 3 OD496513/2024-2025:casing pipe 140 mm dia 6kg/cm2 PVC 4 OD496512/2024-2025:Cost of 1 No 140 mm dia PVC end cap 5 OD496516/2024-2025:Supply and fixing 5 hp motor pump of approved brands including all cost of conveyance labour etc complete 6 OD496520/2024-2025:Supply and fixing pump starter with control panel for 5 hp mortor pump setincluding all cost of conveyance labour etc complete 7 OD496511/2024-2025:Supply and fixing 3 phase pnnel board including all cost of conveyance labour etc complete 8 OD496515/2024-2025:Supply and fixing 6 mm cable including all cost of conveyance labour etc complete 9 OD496518/2024-2025:Supplying 16 mm plastic rope 10 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 11 OD496519/2024-2025:1.001- Specification code: Supplying and fixing 40 mm dia 10 kg/cm2 HDPE pipe PE - 80 including specials and all fitting charges but excluding trenching and refilling etc. complete. 12 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 13 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 14 7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 15 OD521302/2024-2025:DR RUBBLE MASONARY, -Dry rubble without concrete levelling course masonary with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc.complete as per direction of departmental officers at site 16 50.6.2.3:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete 17 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 18 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 19 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 20 9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm 21 9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. U cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). 22 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 23 OD514527/2024-2025:Providing nad fixing 0.35mm thick GI tile profile/traffold sheets roofing up to any pitch and fixing with polymer coated J or L hooks ,bolts and nuts 8mm dia GI plain and bitumen washer or with self drilling fastener and EPDM washers etc.complete (excluding cost of purlin rafters and trusses)including cutting sheets to size and shape wherever required 24 OD503716/2024-2025:Supplying and fixing RCC Door frame 80*195 25 OD496517/2024-2025:Granite name board
Contract Date: Jun 16, 2026 Contract Value : 3.99 Lakh
Government Departments No of Bidders 1
24.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
25.
Housing Urban and Rular Development #11299927 AOC
Tender For Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of: , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead :Of Sectional Area 40 Square Centimetres And Above , Providing And Laying In Position Cement Concrete 1:4:8 (1 Cement : 4 C/Sand : 8 St. Agg. 40 Mm Size) Excluding The Cost Of C/Shuttering - All Work Upto Plinth Level. , Brick Work With F.P.S. Bricks Of Class Designation 75 In Super Structure Above Plinth Level Upto Floor V Level In Cement Mortar 1:6 (1 Cement : 6 C/Sand). , Reinforced Cement Concrete Work In Beam,Suspended Floor Roof Having Slop Up To 15 Degree Landing Balcony Shelf Chajjas Lintels Band Plain Windoe Cills Staircase & Sprial Stair Case Etc. Up To Floor Five Level,Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate20 Mm Nominal Size) , Centering And Shuttering I/C Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , Reinforcement For Reinforced Cement Concrete Work I/C Straightening, Cutting, Bending, Placing In Position And Binding All Complete --Thermo - Machanically -Treated Bars. , Half Brick Masonry With F.P.S. Bricks Of Class Designation 75 In Superstructure Abov Plinth Level Upto Floor V Level In Cement Morar 1:4 (1 Cement :4 Sand) , 12 Mm Cement Plaster Of Mix. 1:6 Cement And Fine Sand Mortar. , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :1:6 (1 Cement: 6 Fine Sand) , Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 154 77, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1 :3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Laying In Position Cement Concrete Of Specified Grade 1:2:4 (1Cement :2 Sand : Stone Aggregate 40Mm Nominal Size) Excluding The Cost Of Centring And Shuttering - -All Work Upto Plinth Level , Providing And Applying White Cement Based Putty Of Average Thickness 1Mm Of Approved Brand And Manufacture, Over Plastered Wall Surface To Prepare The Surface Even And Smooth Complete , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade :New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour : , Painting Steel Work With Deluxe Multi Surface Paint Of Req. Shade (Two Or More Coats) Applied Over An Under Coat Of Primer Approved Brand. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc. Iinternal Work - Exposed On Wall 15 Mm Dia. Nominal Bore , Providing And Fixing Brass Bib Cock Of Approved Quality 15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock Of Approved Quality 15 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) 15 Mm Nominal Bore High & Low Pressure With Plastic Floatsof Approved Quality Complete , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Tank Isi : 12701 Marked With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 25 Mmnominal Bore , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is: 5382, Leaving 10 Mm Gap For Thermal Expansion, () Single Socketed Pipes. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is: 5382, Leaving 10 Mm Gap For Thermal Expansion, () Single Socketed Pipes75 Mm Diameter , Providing And Fixing Pvc Door Frame Of Size 50X4 7 Mm With A Wall Thickness Of 5 Mm (± 0.2 Mm), Made Out Of Single Piece Extruded Pvc Profile, With Mitred Cut Joints And Joint With 2 Nos Of Pvc Bracket Of Size 190 Mm X 100 Mm Long Arms Of Cross Section Size 35 X 15 Mm & Self Driven Self Taping Screws, The Vertical Door Profiles To Be Reinforced With 40X20 Mm M.S. Rectangular Tube Of 0.8 Mm , Including Providing Epdm Rubber Gasket Weather Seal Throughout The Frame, Including Jointing 5 Mm Pvc Frame Strip With Pvc Solvent Cement On The Back Of The Profile. The Door Frame To Be Fixed To The Wall Using 8 X100 Mm Long Anchor Fasteners Complete, All As Per Manufacturers Specification And Direction Of Engineer -In- Charge. , 35 Mm Thick Factory Made Solid Panel Pvc Door Shutter, Made Out Of Single Piece Extruded Soild Pvc Profiles, 5 Mm (± 0.2 Mm) Thick, Having Styles & Rails (Except Lock Rail) Of Size 95 Mmx 35 Mm X 5 Mm, Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered ( On Both Side), Having One Side Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power, Including Reinforcing With Ms Tube Of Size 40 Mm X 20 Mm X 1 Mm, Joints Of Styles & Rails To Be Mitered Cut & Joint With The Help Of Pvc Solvent Cement, Self Driven Self Tapping Screws & M.S. Rectangular Pipes Bracket Of Size 190 Mm X 100 Mm Of Cross Section Size 35 Mm X 17 Mm X 1 Mm At Each Corner. Single Piece Extruded 5 Mm Thick Solid Pvc Lock Rail Of Size 115 Mm X 35 Mm, Out Of Which 75 Mm To Be Flat And 20 Mm To Be Tapered At Both Ends, Having 15 Mm Solid Core In Middle Of Rail Section Integrally Extruded, Fixing The Styles & Rails With The Help Of Solvent And Self Driven Self Tapping Screws Of 125 Mm X 11 Mm, Including Providing 5 Mm Single Piece Solid Pvc Extruded Sheet Inserted In The Door As Panel, All Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C. Brass Pillar Tap. , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms15mm Nominal Bore.. , Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete , Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth 102Mm, Height Of 75Mm With Concealed Fitting Arrangements Weighing Not Lessthan 106 Gms. , Providing And Fixing Mirror Of Superior Glass (Of Approv Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. With Plastic Moulded Frame Of Approved Make And Shades With 6 Mm Thick Hard Board Backing:Rectangular Shape 453X357mm , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests , Marble Stone Flooring With 18 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1 :4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Grey Cement Slurry, Including Rubbing And Polishing Complete With : Udaipur Green Marble , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Persqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories Of Total Coated Thickness 0.50 Mm (Base Metal Of Minimum 0.45 Mm Thickness With Total Coating Thickness Of 0.05 Mm) With Zinc Coating 120 Gram Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Gutter (600 Mm Over All Girth) , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Is 8225:1987, Light Reflectance Of 85% (Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bs:476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991, In True Horizontal Level Suspended On Inter-Locking Metal Powder Coated T-Grid Of Hot Dipped Galvanised Iron Section Of 0.40 Mm Thick On Silhouette Profile,Rotary Stiched Double Webbed White With 6 Mm Reveal Profile (White/ Black),Comprising Of Main-T Runners Of Size 15X42 Mm Of Length 3000 Mm, Cross - T Of Size 15X42 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 15X42 Mm Of Length 600 Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 22X19x0.40 Mm Of Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge.With 15 Mm Thick Integral Densified Micro Edge Light Weight Calcium Silicate False Ceiling Tiles , Providing And Fixing Thermal Insulation Of Ceiling (Under Deck Insulation) With Resin Bonded Rockwool Conforming To Is: 8183,Density 48 Kg/ M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Ceiling With Metallic Cleats (50X50x3 Mm) @ 60 Cm And Wire Mesh Of 12.5 Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete :250X16 Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :250X10 Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Gradeac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete :125 Mm , Providing & Fixing Glass Panes With Putty And Glazing Clips In Steel Doors, Windows, Clerestory Windows Alll Complete With5.5 Mm Thick Glass Panes , Providing Fixing 8Mm Diacp/Ss Jet With Flexible Tube Up To 1 Meter Long With Ss Triangular Plate To Eureopean Type Wc Of Quality And Make As Approved By Engineer In Charge , Constructing Brick Masonry Chamber For Underground C.I. Inspection Chamber And Bends With 75 Class Designation Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Finishedwith F.P.S. Bricksinside Dimensions 455X610 Mm And 45 Cm Deep For Single Pipe Line : , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Non-Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:30 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws , Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes (Weight Not Less Than 10 Kg Per Sqm) Fixing With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size Wit H Necessary Screws .Second Class Teak Wood30 Mm Thick , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required :Size 600X450x200 Mm , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash &Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. Three Track Three Panels Sliding Window With Two Glazed & One Wire Mesh Panels With Aluminium Channel For Roller Track, Wool Pile, Nylon Rollers With Ss 304 Body. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface Forplaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. , Providing And Laying Polished Granite Stone Flooring In Requireddesign And Patterns, In Linear As Well As Curvilinear Portions The Building, All Complete As Per The Architectural Drawings, With18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cementmortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cementslurry And Pointing With White Cement Slurry Admixed Withpolishing Etc. All Complete As Specified And As Directed By Theengineer-In-Charge.Polished Granite Stone Slab Jet Black, Cherry Red, Elitbrown, Cat Eye Or Equivalent. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead :Of Area 3 Sq. Metres And Below , Disposal Of Moorum/Building Rubbish/ Malba/ Similar Unserviceable , Dismantled Or Waste Material By Mechanical Transport Including Loading, Transporting , Unloading To Approved Municipal Dumping Ground For Lead Upto 1 0 Km For All Lifts, Complete As Per Directions Of Engineer-In-Charge . , Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40 Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required : Size 600X450x200 Mm , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/ Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Lnline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware, Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367 : Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge.Using R2 Series With Frame (39 Mm & Above) X (39 Mm & Above). (Height Upto 1.2 Metre) , Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honeycomb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Longcomplete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.In All Kinds Of Soil. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Cement Mortar 1 :6 (1 Cement: 6 Coarse Sand) , Cement Plaster 1:3 (1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement.20 Mm Cement Plaster
Contract Date: Jun 15, 2026 Contract Value : 19.78 Lakh
Government Departments No of Bidders 5
Uttarakhand View Result →
26.
Educational and Research Institute #11294674 Price Bid
Tender for Purchase Of Equipments ( S.No 1 To S.No 21 ) For Physics Department , Purchase Of Equipments , Joule Calorime Copper Vessel, Battery Eliminator-3A, (2,4,6,8,10,12 V), Tubular Rheostat 20-3.3A, One Way Plug Key, Analog Type Dc Ammeter (0-2A), Voltmeter (0-5V), Thermometer (Alcohol), Stop Clock , Ic Regulated Battery Eliminator Ic Regulated, Input: 230V Ac; Output: 0-12V Dc In Steps Of 2V; Capacity: 1A Or 2A , Galvanometer Moving Coil Type, 30-0-30 Scale, Unbranded With Bhel Specification-Sensitivity 0.143Mm/V , Voltmeter Dc Voltmeter; Range 0-10 V, Analog , Ammeter Dc (0 - 2 Amp) , Parallelogram Apparatus Parallelogram Law Of Forces Apparatus Fitted With Stand , Decade Resistance Box Resistance Box 12 Month Warranty (Dial Type) -Manganin Coil- 2 Dials , Sonometer Apparatus Sonometer With Meter Scale Attached Along With Knife Edge, Tuning Forks Set 256, 384, 512 Ranges, Hammer, Slotted Weight - 500 Gm Each To A Total Of 3 Kg. Brass Wire (5 M) , Travelling Mircroscop Branded Travelling Microscope 0- 200 Mm Horizontal And 0-150 Mm Vertical Measurement , Potentiometer It Features A 1-Meter To 10-Meter Constantan/Manganin Wire Stretched On A Wooden Or Sunmica Baseboard With A Millimeter Scale. It Includes 4Mm Brass Terminals, A Pencil Jockey For Contact, Wire Options (10 Wires), And A Typical Resistance Range Of 10-20 Ohms, Ideal For High-Precision Voltage Measurements. , Viscosity Apparatus Stokes Apparatus With Metre Scale Attached And Long Cylindrical Glass Jar, Glass Beads Small Size (1 Box), Screw Gauge (0-15 Mm) , Rheostat High-Grade Ceramic Tube, Oxidized Resistance Wire, 0.5A-5A, Range 10Ω-100Ω. , Deflection Magnetometer Apparatus Deflection Magnetometer Apparatus With Compass Box And Two Short Bar Magnets , Solar Cell Kit The Apparatus Consist Of Variable Dc Power Supply, Led, Solar Cell And Two Multimeters (Or An Ammeter And A Voltmeter). A Variable Dc Power Supply Of 0-5V. Light Source Is Provided By Led. The Illumination Intensity Of The Led Can Be Controlled , Wheatstone Bride Kit Series Arm: Four Decade Dials In Steps Of Thousands, Hundreds, Tens, & Units Of Ohms. Ratio Arm: The Ratio Arm Of The Bridge Is Capable Of Selecting Multiplying Factor Of 0.001, 0.01, 0.1, 1, 10, 100, 1000 For Resistance Measurements. Two Press Keys Are Provided, One Marked B Is For Battery & One Marked G Is For Galvanometer One Toggle Switch Is Provided For Internal Battery A Sensitive Galvanometer Is Provided In The Bridge. , OhmS Law Verification Kit Battery Eliminator-3A, (2,4,6,8,10,12 V), Tubular Rheostat 20-3.3A, One Way Plug Key, Analog Type Dc Ammeter (0-2A), Voltmeter (0-5V), Standard Resistance Coil Of 1, 2 Ohm (2-Set) Wound On A Wooden Bobbin , BoyleS Law Apparatus The Apparatus Includes The Quill Tube, A Retort Stand, A Clamp, And A Mounted Meter Scale. Quill Tube Specifications: Length: Approximately 50 Cm. Bore Diameter: Uniform Bore, Roughly 1 Mm To 2 Mm. Construction: Glass Tube With One End Sealed. Trapped Substance: A Mercury Pellet (Or Thread) Of Length 10 To 15 Cm Is Introduced To Enclose A Column Of Air. Mounting: Attached To A Half-Meter Or Meter Scale. , Torsion Pendulum Torsional Pendulum Metallic Disc, Symmetrical Masses And Pendulum Stand, Steel Wire , Compound Bar Pendulum One Meter Long Iron Strip Well Painted With Holes At A Distance Of Every 5 Cm And Also With Pair Of Brackets And A Heavy Base Table Top Stand With Stop Clock , Helical Spring Apparatus Structure: A Rigid Support Mounted On A Heavy Metal Base, Typically Cast Iron, To Ensure Stability During Tests. Springs: High-Tensile Steel Spiral Springs, Typically (Approx 25 Mm) Diameter, (100 Mm) Long. Measurement Scale: A Vertical Steel Meter Scale, Usually With (1Mm) Graduations, For Precise Deflection Measurement. Loading Mechanism: A, Typically (50G), Hook-Attached Weight Hanger At The Bottom.Pointer: A Fine Pointer Attached To The Bottom Of The Spring Moves Along The Scale. Accessories: Includes A Set Of Slotted Weights (E.G., (6Times 50G) Or Similar Sets) For Incremental Loading. , Meter Bridge Type: 1 M Length, With Uniform Wire (Resistance Wire) Material: Constantan Or Manganin (Low Temperature Coefficient) Scale: 0-100 Cm, Engraved Or Printed Base: Wooden Or Metal, Rigid, Non-Conductive Support Joints / Terminals: Brass Or Copper, Fixed For Connections 2. Galvanometer Type: Analog, Moving Coil Or Digital (For Null Detection) Range: Sensitive To Detect Micro-Ampere Currents Internal Resistance: High, Typically ~100 Ω Or As Specified 5. Cells / Power Supply Type: Leclanché Cells (1.5 V Each) Or Dc Power Supply Number: 2-4 Cells In Series (Or Supply ~3-6 V) 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
27.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
28.
Housing Urban and Rular Development #11287952 Technical Bid
Tender for Construction Of Temporary Pandals, Barricades, Sheds, Temporary Offices And C S Etc. At Location- (1) Kamakhya Railway Station, Maligaon (2) Pandu Port (3) Naharbari Field (4) Bongshi Bagan And Other Temporary Structures At Different Locations From Foot Hills To Main Entrance Of Maa Kamakhya Temple In Connection With The Ambubachi Mahayog, 2025 At Guwahati. (Civil Works) , Erection Of German Technology Aluminium Structure As Per Manufacturer Specification With Pvc Tensile Fabric Fitted To Frames With Necessary Cross Bracing, Wind Tie & Struts As Necessary (All Materials Are Contractors Property) , Construction Of Pandel Made With Bhaluka Bamboo Post 100Mm To 150Mm Dia And Sal Bali Post Of Various Length From Eve Point To Ridge Point Driven Atleast 90Cm. For Soil Boil Post & 75Cm For Bhaluka Bamboo Posts On The Ground With Jati Bamboo Roof Base As Per Drawing Type With Coir Rope Including Jati Bamboo Brasing Alternative Post Sal Timber Bali Posts One To Be Provided In Two Middle Rows At 4.55M Apart And Bhaluka Bamboo Post In Other At 3.00 Apart. The Jati Bamboo Rafter Should Be Fixed At Ground As Directed And Specified And Dismantling The Pandal After The Function Within Three Days Time. (The Bamboo & Coir Rope Etc. Will Be Contractors Property) Work To Be Executed As Directed By The Department. Pandel Made With Bhaluka Bamboo Post With Eve Height 4.20M & Ridge Height 13.70M. , Fitting & Fixing Pvc Fire Resitant Tarpolin Over The Steel Roof/Bamboo Roof Truss Frame And Plastic Rope Etc. And Removing The Same After The Function As Directed. (All The Materials Are Contractors Property) , Kutchi Design Cloth Decoration In Ceiling Of The Pandal And Side Decoration Of The Pandal With Kutchi Design Cloth Etc.Complete As Directed.(All The Materials Are Contractors Property) , Providing View Cutter With Heavy Duty Rope Over The Tarpolin Roofing Walling Etc. Complete As Directed. , Temporary Wooden Flooring 150Mm Height Over The Ground With 19Mm Thick Ply Wood Including Fitting And Fixing With Iron Screw, Nails Etc. As Directed By The Deptt. , Hire Charge Of Red Carpet Including Carriage As Directed By The Department. , Erection Of Steel Tubular Pipe (60.3Mm Od) Barricading Of 1.50M High With Steel Pipe Post @1.80M C/C Driven At Least 0.60M With 4 Nos Of Horizontal Steel Pipe Railing Tied With Nut And Bolt With Vertical Member Complete Including All Cost Of Carriage And Labour For Construction As Well As Removing The Same After The Function Is Over As Directed And Specified By The Department. (The Dismantled Steel Pipes Received From Dismantlimg Of Barricade Will Be The Contractor Property After Adjusting Salvage Value) , Hire Charge Of Plastic Chairs Including Carriage As Directed By Department. , Hire Charge Of Table , Construction Of Stage Of 2.00 M High With 50Mm Dia Steel Pipe Fixing With Cross Pipe With Bolt And Nut. The Post Are At A Distance Of 1.20 M Apart And The Platform With......... Steel Frame Staircase As Directed By The Department. (All The Materials Are Contractors Property) , Hire Charge Of Vip Chairs Including Carriage As Directed By Department. , Hire Charge Of Sofa Set As Directed By The Department. , Flower Decoration For Stage With Natural Flower And Flower Tubs Including Carriage Complete. , Construction Of Vvip Toilet Block Of Size 3.65 X 2.50M With All Fitting Fixings Etc. , Providing Bamboo Barricade With Bamboo Post Of Ht. 2.10 M Above The G.L. And .60M Below The G.L At An Interval Of 1.5M Having 2.00M Length And Fixing Of Jati Bamboo Horizontally At Interval Of .50Mc/C With Carriage As Directed By The Deptt. (After Completion The Function, The Contractor Is Allowed To Collect And Clearing The Unserviceable Bamboo From The Site) , Hire Charge For Podium , Hire Charge For Wooden Chair , Hire Charge For Proper Arrangement Of Coffee Tables To Be Made For Vip And Vvip Sitting Area.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
29.
Housing Urban and Rular Development #11286216 AOC
Tender For Construction Of New Primary Health Center (Phc New Bldg) At Perumalmalai H/O Adukkam, Kodaikanal Block.; 2 Clearing lightjungle vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. 4 Supplying and filling in foundations and basement with fillingM sand in layers not exceeding 15 cm. thick, well watered ,rammed and consolidated etc. complete complying with standard specifications. 5 Plain Cement Concrete 1 : 4 :8 ( one part of cement, four parts of sand and eight parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement. 6 Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site. 7 Supplying and filling of good earth filling locally available earth transported from the outside including consolidation,leveling specifiedin layers of not exceeding 200 mm thick., etc. complete. 8 Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification.(Payment for centering shall be given after the concrete is laid). 9 Upto Basement 10 Ground Floor 11 First Floor 12 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.-1m3 13 Foundation & Basement 14 Ground Floor 15 First Floor 16 Steel - Fe 500D : Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers. 17 Brick work in following Cement Mortar 1:5 using best quality Country bricks of size 83/4 x 41/4 X2 3/4 for foundation and basement including curing etc., complete complying with standard specification. Including scaffolding curing cost of reinforcement etc. all complete as per specifications and drawings as directed by the Engineer in-charge. 18 Foundation basement 19 Ground floor 20 First floor 21 Brick partition walls of 11.50cm thickness using best quality Country bricks of size 83/4 x 41/4 X2 3/4in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 22 Ground Floor 23 First Floor 24 PLASTERING WORK 25 Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing.The Surface shall then be allowed to dry for atleast 48 hours.It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface.Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete].The Putty shoule be got approved by the Executive Engineer before use on work. 26 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and ThreeM.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 27 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent andas directed. 28 FLOORING AND DADOOING 29 Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved color, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same color pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic Cost-Rs.776/sq.m 30 Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic cost-Rs.464/sq.m 31 Dadooing the walls with colouredDadooing Ceramic tiles of size 150mm x 150mm x 6mm approved size , quality and colour set in CM 1 : 2 - 10 mm thk. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surfacein all floors at the rate of 0.40 Kg /Sqm etc. complete. 32 Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 33 Providing, fabricating and fixing M.S. grillsWindows,and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer. 34 S.S Handrail 35 Manufacturing,supplying and fixing of stainless steel handrails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete. 36 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete 37 Supply and Fabrication of UPVC doorincluding cost and conveyance of all charges etc complete. 38 Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. 39 UPVC Windowsupplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sectionwith wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plainglass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and shouldhave key lockable action, security protective hinges, strong lockingsystems and as per sizefor arrestingnoise and energy loss. 40 UPVC VENTILATOR: Supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSMand 100% corrosion free , the profile are multi chambered sections withwall thick of 2mm. The EPDM rubber (black color) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all around the frame. The ventilator should be got approved from the Executive Engineer before use on work. 41 PAINTING WORK 42 Painting two coats of synthetic Enamel paint of approved colour and make over one coat of anti corrosive Zinchromite primerover new wood / steel work, suitably prepared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of filler, primer, paint all complete as per drawings and specifications. 43 Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). 44 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 45 Weathering Course Concrete using best quality broken brick jelly of 20 mm uniform gauge in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jiggery water etc. complete complying with standard specifications and as directed 46 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 47 Plumbing Work 48 Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap withseat cover, supplyingnon corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L -brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, groutingwith cement concrete 1:2:4 mix, using 20mm size stone jelly,restoring the damaged portion to their original condition using required materials,fixing the water closet to perfect level,alignment,testingetc.complete. 49 Providing and keeping in stores, shifting to the place of installation, fixing,testing and commissioning ofwhite coloured vitreous china under counterRegular rectangular wash basin with brackets/ G.I. rag bolts and nuts painted,32mm dia brass C.P. waste coupling, (heavy) 32mm diabrassC.P.bottletrap,15mmdiabrassC.P.Anglestopcockwith flange, 15mm dia brass C.P. coldwater connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors- toilets. Wash Basin 50 Supply & Fixingat sitein position 15mm dia C.P brass BIB COCKS long body with wall flangeincludingcuttingandmakinggoodthe wallswhereverrequired 51 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 52 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 53 Supplying and fixing in positionC.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.(D) 54 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition,including testing for any leakages,etc.,complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 55 a) 40mm dia. 6kg class PVC pipes. 56 b) 50mm dia. 6kg class PVC pipes. 57 c) 75mm dia. 6kg class PVC pipes. 58 d) 110mm dia. 6kg class PVC pipes. 59 Supplying and fixing in position cost iron Nahini / Floor trap with Stainless steel grating / PVC nahini / Floor Trap with PVC Grating type of size 100 x 75 / 75 x 50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1;2;5 (One lime two sand and five aggregate ) brick jelly 40mm and finishing with cm 1;3(One cement and three sand) including dismantling masonary wherever found necessary and making good to the original condition and giving connections to the cast iron pipe etc, complete complying with standard specififcation and as directed by the departmental Officers. 60 Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such asBend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc.,complete. 61 b).110mm dia. 4kg class pipes. 62 Supplying and fixing in position of the following dia PVC rain water gratings for rain water pipes ,of approved quality and varietyof various size confirming to ISS andincluding necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 63 110mm dia 64 Supplying and fixing in position of the following dia PVC specials such asPVC vent Cowl etc.,of approved quality and varietyof various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 65 a)75mm Dia 66 b)110mm Dia 67 PART-C - EXTERNAL DRAINAGE 68 Soil/ Waste Pipes 69 Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and varietyof various size confirminghaving ISI mark and providing leak proof joints including erection of below groundwith excavation and refilling etc.,and making connection to Manholes /Gully trap,wherever necessary and making chipping good portion to the original condition,complying with standard specification etc., complete. 70 160mm dia. 6kg class III-pipes. 71 Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface withProviding and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std.specification. 72 Supplying and Erection and construction of sewer chambers of required internal dimensions 600x600 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 600x600mm (clear opening)complete complying with standard specifications etc., 73 Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings,including all types of excavation, occur for pipe,filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing. 74 Supplying and fixing of PVC water storage tank of best approved quality and make of super thick with lid ofcapacity of 2000 litres with accessories including giving necessary connection etc., complete as directed by the departmental officer. (The PVC water storage tank should be got approved by the Engineer before use on work)(TWAD- Pano:173) 75 provision for rainwater harvesting structure 76 Electrification 77 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) 78 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End 79 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End 80 Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.) 81 Supply and fixing of fancy glass shade and 7W / 9W LED bulb 82 Supply and fixing of single box type 440W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting 83 Supply and fixing of AC / DC 76mm buzzer / call bell suitable for 230 volts 50 c/s single phase AC supply on suitable TW board with push switch 84 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 300mm down 85 Supply and fixing of 300mm (12) sweep (light duty) AC exhaust fan complete without provision of hole in the wall 86 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 87 Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 88 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug) 89 Supply and fixing of 8 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 24 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 90 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 91 Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipeconcealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of theconcealed portion with suitable colour 92 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. 93 Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitablecolour 94 Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6 sq.mm copper wire with painting of suitablecolour 95 Supply and run of 1 of No.8 SWG GI wire for earth connection 96 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earthconnection 97 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm 98 Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2 x 1-1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection with earth connection complete 99 Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only 100 Supply and fixing of 63A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing 101 Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection 102 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 103 Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 104 Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 105 Supply and Laying of 3 1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 106 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 107 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 108 Septic Tank 109 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 110 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 111 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 112 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 113 REINFORCED CEMENT CONCRETE M25 1:1.5:3 mixusing 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the RCC floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (One cement and three sand ) and Kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers. 114 Brick work in following Cement Mortar using best quality of Country Bricks of size 8-3/4 x 4-1/4 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 115 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andas directed. 116 Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete. 117 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost). 118 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 119 Under Ground Sump 120 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 121 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 122 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 123 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 124 Reinforced Cement Concrete 1:11/2:3 (One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers 125 Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 ( One part of Cement and Three parts of Sand ),to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams,and Sun shades etc.to correct plane and l 126 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of 25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost) 127 Supplying and fixing in position C.I.Manhole covers (heavy duty) of various sizes of best approved quality and as per standard specificationsetc.,complete.0.6X0.6M Size etc., complete. 128 PVC mould CI steps for sump 129 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 130 Aluminium ladder for maintenance over the Roof top 131 Provision for lab interior 132 Tactile Flooring and Braille Sign Board 133 Provision for Sitting bench and Cubboard Arrangements 134 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package}
Contract Date: Jun 13, 2026 Contract Value : 1.68 Crore
Local Bodies No of Bidders 2
30.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
31.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
33.
Public Administrative Department #11258623 AOC
Tender For Late Maharshi Annasaheb Shinde School to carry out various development works at this place=ITEM NO : 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m.) By Manual Means ( SSR Item No : 21.01 ) (PMC Bhavan ) Unique No (15201) Rate List Year (2024-2025) ITEM NO : 2 Transportation of material obtained from excavation including soil, Cu.M rubble, bricks, RCC concrete, kerb stones, steel railing, iron pipes, channels etc. Obtained from excavation, dismantling, loading in a Truck of minimum 5 Cu M capacity or designed capacity and transporting within the municipal limits or any designated place, unloading, stacking or spreading of material etc. complete. As directed by Engineer In charge ( SSR Item No : 78.36 ) (PMC Bhavan ) Unique No (17223) Rate List Year (2024-2025) ITEM NO : 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete ( SSR Item No : 46.19 ) (PMC Bhavan ) Unique No (16026) Rate List Year (2024-2025) ITEM NO : 4 Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. ( SSR Item No : 33.67 ) (PMC Bhavan ) Unique No (15532) Rate List Year (2024-2025)ITEM NO : 5 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. ( SSR Item No : 33.27 ) (PMC Bhavan ) Unique No (15495) Rate List Year (2024-2025) ITEM NO : 6 Providing internal cement plaster 12 mm thick in a single coat using Ready to use wall plaster to concrete or brick surface in all positions including scaffolding and curing complete. Providing groove at joint of B.B. Masonry and concrete members complete. c) cement ratio 1:3 With Prior Approval of Concerned S.E. ( SSR Item No : 51.F-108 ) (PMC Bhavan ) Unique No (16252) Rate List Year (2024-2025) ITEM NO : 7 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary ( SSR Item No : 35.26 ) (PMC Bhavan ) Unique No (15576) Rate List Year (2024-2025) ITEM NO : 8 Wall Painting art work : painting artistic work on any type of surface and at any height using scaffolding with skilled artists as per the instructions of site incharge.measurement will be as per actual max.size of art.rate for background apex paint and lettring will be paid seperately ( SSR Item No : 63.4 ) (PMC Bhavan ) Unique No (16694) Rate List Year (2024-2025) ITEM NO : 9 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. ( SSR Item No : 36.11 ) (PMC Bhavan ) Unique No (15587) Rate List Year (2024-2025) ITEM NO : 10 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. ( SSR Item No : 35.12 ) (PMC Bhavan ) Unique No (15563) Rate List Year (2024-2025) ITEM NO : 11 Providing and fixing frame with / without ventilator of size as specified with Country non teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. ( SSR Item No : 39.2 ) (PMC Bhavan ) Unique No (15676) Rate List Year (2024-2025) ITEM NO : 12 Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. ( SSR Item No : 39.10 ) (PMC Bhavan ) Unique No (15684) Rate List Year (2024-2025) ITEM NO : 13 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. ( SSR Item No : 46.15 ) (PMC Bhavan ) Unique No (16022) Rate List Year (2024-2025) ITEM NO : 14 Providing and fixing 24 gauge plain aluminium sheet on the face of door shutter including cutting to required size and fixing the screws including making good the damages if any to existing door shutter and frame etc. complete as directed or as per detailed drawing ( SSR Item No : 39.62 ) (PMC Bhavan ) Unique No (15739) Rate List Year (2024-2025) ITEM NO : 15 Providing and fixing Orissa type white glazed earthenware water closet pan of size 260mm x 440mm x 580mm with approved make Slim wall hung cistern with installation kit including S or P trap with cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete. ( SSR Item No : 48.42 ) (PMC Bhavan ) Unique No (16111) Rate List Year (2024-2025) ITEM NO : 16 Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. ( SSR Item No : 42.34 ) (PMC Bhavan ) Unique No (15886) Rate List Year (2024-2025) ITEM NO : 17 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. ( SSR Item No : 41.63 ) (PMC Bhavan ) Unique No (15838) Rate List Year (2024-2025) ITEM NO : 18 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres ( SSR Item No : 42.54 ) (PMC Bhavan ) Unique No (15906) Rate List Year (2024-2025) ITEM NO : 19 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. ( SSR Item No : 42.52 ) (PMC Bhavan ) Unique No (15904) Rate List Year (2024-2025) ITEM NO : 20 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. ( SSR Item No : 31.05 ) (PMC Bhavan ) Unique No (15422) Rate List Year (2024-2025) ITEM NO : 21 Providing and laying River Finish kota Stone Flooring 50mm to 60mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. etc. complete. ( SSR Item No : 60.08 ) (PMC Bhavan ) Unique No (16469) Rate List Year (2024-2025) ITEM NO : 22 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) ( SSR Item No : 25.11 ) (PMC Bhavan ) Unique No (15317) Rate List Year (2024-2025) ITEM NO : 23 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number : As directed by Engineer-in-charge. ( SSR Item No : 23.07 ) (PMC Bhavan ) Unique No (15303) Rate List Year (2024-2025) ITEM NO : 24 Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super bib tap with flange including all accessories etc complete ( SSR Item No : 43.35 ) (PMC Bhavan ) Unique No (15975) Rate List Year (2024-2025) ITEM NO : 25 Building (Bd-V : Water supply and sanitory fittings)Upvc sanitary pipes all 15 mm dia. ( SSR Item No : 49.V-354 ) (PMC Bhavan ) Unique No (18025) Rate List Year (2024-2025) ITEM NO : 26 Building (Bd-V : Water supply and sanitory fittings)Upvc sanitary pipes all 25 mm dia. ( SSR Item No : 49.V-353 ) (PMC Bhavan ) Unique No (18024) Rate List Year (2024-2025) ITEM NO : 27 Building (Bd-V : Water supply and sanitory fittings)P.V.C.Flushing tank (12 ltr. Capacity) ( SSR Item No : 49.V-202 ) (PMC Bhavan ) Unique No (17873) Rate List Year (2024-2025) ITEM NO : 28 Building (Bd-V : Water supply and sanitory fittings)super jet spray with flange 2 in 1 faucet 1.50 metre long SSR Item No : 49.V-385 ) (PMC Bhavan ) Unique No (18056) Rate List Year (2024-2025) ITEM NO : 29 Building (Bd-V : Water supply and sanitory fittings)Ball cock for 32mm dia. SSR Item No : 49.V-279 ) (PMC Bhavan ) Unique No (17950) Rate List Year (2024-2025) ITEM NO : 30 Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. SSR Item No : 46.39 ) (PMC Bhavan ) Unique No (16044) Rate List Year (2024-2025) ITEM NO : 31 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. SSR Item No : 39.37 ) (PMC Bhavan ) Unique No (15711) Rate List Year (2024-2025) ITEM NO : 32 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram / Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box SSR Item No : 39.41 ) (PMC Bhavan ) Unique No (15715) Rate List Year (2024-2025) ITEM NO : 33 Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). SSR Item No : 38.4 ) (PMC Bhavan ) Unique No (15625) Rate List Year (2024-2025) ITEM NO : 34 Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). SSR Item No : 39.26 ) (PMC Bhavan ) Unique No (15700) Rate List Year (2024-2025) ITEM NO : 35 Providing and fixing 12 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) SSR Item No : 62.11 ) (PMC Bhavan ) Unique No (16542) Rate List Year (2024-2025) ITEM NO : 36 Providing and fixing 19 mm thick waterproof plywood ( durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI) ) ( SSR Item No : 62.12 ) (PMC Bhavan ) Unique No (16543) Rate List Year (2024-2025) ITEM NO : 37 Providing & fixing 1/2”,1/4”to 1” tk Teakwood leaping patti including polishing etc completed. ( SSR Item No : 62.27 ) (PMC Bhavan ) Unique No (16570) Rate List Year (2024-2025) ITEM NO : 38 Laminates sheets 1 mm thick : Providing and fixing laminates sheets as per company specification and fix it with fevicol – Recommended companies- formica, Royal touch, Marino , Green lam , Euro. ( 1 mm thick laminates sheets ) ( SSR Item No : 62.23 ) (PMC Bhavan ) Unique No (16566) Rate List Year (2024-2025) ITEM NO : 39 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Handles ( SSR Item No : 62.29-B ) (PMC Bhavan ) Unique No (16573) Rate List Year (2024-2025) ITEM NO : 40 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) .Hinges ( SSR Item No : 62.29-A ) (PMC Bhavan ) Unique No (16572) Rate List Year (2024-2025) ITEM NO : 41 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. ( 3” to 5”sizes ) . Locks (For cupboards & wardrobes) ( SSR Item No : 62.29-C ) (PMC Bhavan ) Unique No (16574) Rate List Year (2024-2025)
Contract Date: Feb 26, 2026 Contract Value : 19.94 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Madhya Pradesh View Result →
35.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
36.
Educational and Research Institute #11223212 Technical Bid
Tender For Supply And Fixing Of Mechanical Engineering Research Laboratory Furniture(Rp-157) Of New Academic Block At Smvd University, Kakryal, Katra , Research Lab, Mechanical Engineering, Smvd University Katra , Table For Cabin - Providing And Placing Of Main Table With Overall Size Of Table Shall Be 1500 Width Mm X 750 Depth Mm X 740 Height Mm That Is To Be Assembled At Site. The Construction Of The Main Table Shall Be Free Standing Structure Constructed With The Help Of Minifix Dowels And Pins. The Work Top Shall Have The Size 1500Mm X 750Mm Made Up Of 25Mm Thick Particle Board Of Grade Ii Of Is 12823 With Approved Laminate And Finish As Per Approved Shade. The Table Top Profile Shall Be In Rectangle Shape With Front And Back Full Round Post Form And Other Edges Shall Be Sealed With 2Mm Thick Thin Strip Of Impermeable Pvc That Is Cut To Fit The Size Of Board Panel And Duly Pasted With The Assistance Of Edge Banding Machine At 200 Degree Celsius. The Table Top Shall Be Supported Over Particle Board Base Gable End. The End Wall Of The Table On The Side Shall Be Topped By Gable End. The Gable End Shall Be Made Up Of 25Mm Thick Particle Board And Profile Shall Be In Linear Shape With Front And Back Full Round Post Form And Other Edge With Appropriate Pvc Edge Banding. The Table Shall Be Clad With 18Mm Thick Modesty Panel Which Provide Structural Support For The Table. It Should Be 18Mm Thick Pre-Laminated Particle Board With Appropriate Pvc Edge Banding Connected With Both End. There Shall Be Buffers Provided At The Base To Avoid Scratches On The Floor. A Mobile Pedestal Shall Be Provided With An Overall Size 400Mm X 450Mm X 660Mm. The Pedestal Shall Be Made Up Of Pre-Laminated Particle Board Of Grade Ii Of Is 12823. Pedestal Side, Back, Top, Facia Shall Be 18Mm Thick And Drawer Base Shall Be 9Mm Thick. The Pedestal Shall Have 3 Nos. Of Drawer I.E. 2 Box Drawer And 1 Filing Drawer. The Drawer Shall Be Operated With Ss Handle And Easily Close & Open With The Assistance Of Roller Channel And Ball Bearing Channel Having To Enable Smooth Operation. The Drawer Shall Have Central Locking Mechanism In Which All The Drawer Shall Be Synchronized Locked With One Single Key. The Pedestal Shall Be Mounted Over 50Mm Injection Moulded Nylon Castor. Dimensions Tolerance + 20 Mm. , Table For Faculty Cabin - Providing And Placing Of Main Table With Overall Size Of Table Shall Be 2000 Width Mm X 750 Depth Mm X 740 Height Mm That Is To Be Assembled At Site. The Construction Of The Main Table Shall Be Free Standing Structure Constructed With The Help Of Minifix Dowels And Pins. The Work Top Shall Have The Size 1500Mm X 750Mm Made Up Of 25Mm Thick Particle Board Of Grade Ii Of Is 12823 With Approved Laminate And Finish As Per Approved Shade. The Table Top Profile Shall Be In Rectangle Shape With Front And Back Full Round Post Form And Other Edges Shall Be Sealed With 2Mm Thick Thin Strip Of Impermeable Pvc That Is Cut To Fit The Size Of Board Panel And Duly Pasted With The Assistance Of Edge Banding Machine At 200 Degree Celsius. The Table Top Shall Be Supported Over Particle Board Base Gable End. The End Wall Of The Table On The Side Shall Be Topped By Gable End. The Gable End Shall Be Made Up Of 25Mm Thick Particle Board And Profile Shall Be In Linear Shape With Front And Back Full Round Post Form And Other Edge With Appropriate Pvc Edge Banding. The Table Shall Be Clad With 18Mm Thick Modesty Panel Which Provide Structural Support For The Table. It Should Be 18Mm Thick Pre-Laminated Particle Board With Appropriate Pvc Edge Banding Connected With Both End. There Shall Be Buffers Provided At The Base To Avoid Scratches On The Floor. A Mobile Pedestal Shall Be Provided With An Overall Size 400Mm X 450Mm X 660Mm. The Pedestal Shall Be Made Up Of Pre-Laminated Particle Board Of Grade Ii Of Is 12823. Pedestal Side, Back, Top, Facia Shall Be 18Mm Thick And Drawer Base Shall Be 9Mm Thick. The Pedestal Shall Have 3 Nos. Of Drawer I.E. 2 Box Drawer And 1 Filing Drawer. The Drawer Shall Be Operated With Ss Handle And Easily Close & Open With The Assistance Of Roller Channel And Ball Bearing Channel Having To Enable Smooth Operation. The Drawer Shall Have Central Locking Mechanism In Which All The Drawer Shall Be Synchronized Locked With One Single Key. The Pedestal Shall Be Mounted Over 50Mm Injection Moulded Nylon Castor.Dimensions Tolerance + 20 Mm. , Chair For Cabin & Faculty Rooms - Supplying And Placing Ergonomically Designed, Comfortable & Aesthetically Appealing Medium Back Chair. The Seat Shall Be Made Of 15Mm Thick Hot Pressed Malaysian Plywood With Hr Polyurethane Foam 50Mm Thick Having Density 40Kg/M³ Upholstered With Leatherite Tapestry In Black Colour With 0.8Mm Thick And 535 Gsm And The Back Shall Be Made Of Double Layered Malaysian Moulded Hot Pressed Plywood (12+6)Mm Thick With Hr Polyurethane Foam 30Mm Thick Having Density 32Kg/M³ Upholstered With Leatherite Tapestry In Black Colour With 0.8Mm Thick And 535 Gsm. Seat And Back Shall Be Joined With Hr Steel Sheet. The Armrest Shall Be Used Pp Arm Fixed Type Completely Joint With Seat. The Chair Shall Have Synchro Knee Tilt Revolving Mechanism With Four Position Locking And Tilt Tension Adjustment. The Pneumatic Seat Height Adjustable 100Mm With Bifma Standard Class-3 Gaslift. The Pedestal Shall Be Made Up Of Injection Moulded Black Nylon Having Pitch Circle Dia 700 Mm Fitted With 5 Nos. 50Mm Twin Wheel Castors Which Shall Be Made Of Injection Moulded Black Nylon 30% Glass Filled Having Self Lubricating Property For Friction Free Movemen With Bifma Standards. The Seat Size Shall Be 480±10Mm(W) X 495±10Mm(D) And Back Size Shall Be 590±10Mm(H) From Seat & Overall Height = 1030±10Mm. Dimensions Tolerance + 20 Mm. , Executive Table For Cabin 3 - Supplying & Installing Of Table With Eru And Pedestal Having Following Specifications. The Table Shall Be Supplied In Completely Knock Down Conditions With An Overall Size W1800 X D1800 X H750mm That Is To Be Assembled At Site. The Worktop Shall Have The Size 1800 X 900Mm Made Up Of 50Mm Thick Plpb With Approved Laminate And Finish As Per Approved Shade. The Top Edge Should Cladded With 1.2Mm Thick Extruded Aluminium Section All Around The Worktop And Die Cast End Caps On Joints For Better Strength Of The Table. The Profile Shall Be In Rectangle Shape And Enclosed By Flapper Box For Electric Provision. The Top Shall Be Supported On Gable End. The End Wall Of The Table On The Side Shall Be Topped By Gable End. It Should Be 50Mm Thick Medium Density Fibre-Board Linear In Profile And The Edges Cladd With Extruded Aluminium Profile. The Table Shall Be Clad With 18Mm Thick Modesty Panel Which Provide Structural Support For The Table. It Should Be 18Mm Thick Particle Board And Shall Be Linear In Profile. The Table Shall Be Supplied With Credenza Unit With An Overall Size 900Mm X 450Mmmm That Shall Be Constructed From Pre-Laminated Particle Board Of Grade Ii Of Is 12823 With 25Mm Thick Top And Other Parts 18Mm Thick Like Shutter, Back, Facia Etc. The Drawer And Shutter Shall Be Operated With Ball Bearing Sliding Channel And Concealed Crank Hinge. G-Profile Aluminium Handle Shall Be Supplied For Ease Of Opening. The Eru Unit Shall Be Mounted On 38Mm Dia. Leg. Fixed Pedestal Shall Be Supplied With An Overall Size 380Mm X 400Mm X 600Mm. The Pedestal Shall Be Made Up Of Pre-Laminated Particle Board Of Grade Ii Of Is 12823. Top Shall Be 25Mm Thick, Side, Back, Facia Shall Be 18Mm Thick. The Pedestal Shall Have 2 Nos. Of Drawer Having Same. The Drawer Shall Be Operated With Ball Bearing Sliding Channel To Enable Smooth Operation. Aluminium Handle Shall Be Provided For Ease Of Opening. For Locking Provision Central Lock Mechanism Shall Be Given In Which All The Drawer Shall Be Synchronized Locked With One Single Key. The Pedestal Shall Be Mounted On Aluminium Round Leg. Dimensions Tolerance + 20 Mm. , Executive Chair For Cabin 3- Providing And Supplying A High Back Chair With Ergonomic Design, Comfortable & Aesthetically Appealing. The Seat And Back Frame Shall Be Made Up Of The Combination Of 15Mm Thick Hot Pressed Commercial Plywood And Ply-Board Padded With High Resilience Polyurethane Foam (50+25+30)Mm Thick Having Density (40, 32 & 32)Kg/M³ In Seat And (30+25)Mm Thick Having Density (32, 32)Kg/M³ In Back. The Same Shall Be Upholstered With Leatherite Tapestry 0.8Mm Thick And 535 Gsm. The Backrest Shall Be Made By Keeping The Natural Curvature Of The Spine For Lumbar Support Which Helps To Provide Full Back Support As Well As Head Support. Seat And Back Shall Be Covered With Polished Wooden At Both Side For Decorative Appearance. The Chair Shall Be Supplied With Natural Wood Arm Having Melamine Polish And Die Cast Aluminium End Caps. For Seating Durability The Chair Shall Have Torsion Bar 360 Degree Revolving Mechanism With Upright Position Locking And Tilt Tension Adjustment. The Hydraulic Seat Height Adjustment For Healthy Seating, User Can Adjust Seat Height Up To 65Mm With Bifma Standard Class-3 Gas-Lift To Suit Them Using The Lever Under The Seat. The Gas-Lift Mechanism Should Be Tested As Per Ansi/Bifma X5.1-2011 Standards. The Pedestal Should Have Metal Insert Crca Covered With Natural Wood Having Pitch Circle Dia. 630 Mm Fitted With 5 Nos. Twin Wheel Castors. The Castors Of The Chair Should Be Injection Moulded In Black 30% Glass Filled Nylon, Confirming To Ansi/Bifma Standards X5.1-2011 Tested To Perform 98,000 Cycles With 250Lbs Load. The Seat Size Shall Be 510±10 Mm(D) X 510±10 Mm(W) And Back Size Shall Be 525±10 Mm(W) X 710±10 Mm(H) From Seat. Overall Height Shall Be = 1170±10 Mm & Overall Width/Depth = 740±10 Mm.. Dimensions Tolerance + 20 Mm. , Visitor Chair For Cabin 3 - Providing And Supplying A High Back Chair With Ergonomic Design, Comfortable & Aesthetically Appealing. The Seat And Back Frame Shall Be Made Up Of The Combination Of 15Mm Thick Hot Pressed Commercial Plywood And Ply-Board Padded With High Resilience Polyurethane Foam (50+25+30)Mm Thick Having Density (40, 32 & 32)Kg/M³ In Seat And (30+25)Mm Thick Having Density (32, 32)Kg/M³ In Back. The Same Shall Be Upholstered With Leatherite Tapestry 0.8Mm Thick And 535 Gsm. The Backrest Shall Be Made By Keeping The Natural Curvature Of The Spine For Lumbar Support Which Helps To Provide Full Back Support As Well As Head Support. Seat And Back Shall Be Covered With Polished Wooden At Both Side For Decorative Appearance. The Chair Shall Be Supplied With Natural Wood Arm Having Melamine Polish And Die Cast Aluminium End Caps. The Frame Structure Shall Be Cantilever Support Type Made Of Ms Crca Powder Coated 50-60? (Dft) Thick Round Pipe Of Dia. 28.5Mm With 2Mm Thick. There Shall Be Ppcp Shoe Provided At The Base To Avoid Scratches On The Floor. The Seat Size Shall Be 480±10 Mm(D) X 510±10 Mm(W) And Back Size Shall Be 520±10 Mm(W) X 580±10 Mm(H) From Seat. Overall Height Shall Be = 1030±10 Mm, Overall Depth = 620±10 Mm & Overall Width = 620±10 Mm. Dimensions Tolerance + 20 Mm. , 2-Seater Sofa For Cabin 3 - Supplying And Placing Two Seater Sofa That Shall Be Constructed From Natural Hard Wood And Commercial Plywood Having Inner Frame. The Thickness Of The Wood Should Allow For The Heavy Tension Webbing. The Sofa Shall Have Spring Attached And Also Be Padded. The Frame Shall Be Padded With High Resilience Polyurethane Foam Having Density 40Kg/M³ In Seat And 32Kg/M³ In Back. There Shall Be Cushion Arm Provided Padded With High Resilience Polyurethane Foam Having Density 40Kg/M³. The Complete Structure Shall Be Upholstered With Leatherite Tapestry 1±0.2 Mm Thick And 571 Gsm. The Understructure Shall Consist Of Ss 202 Grade Loop Leg With Shiny Chrome Finish Having Cross-Section Area 40Mm X 20Mm With 1.6Mm Thick. There Shall Be Shoe Provided At The Bottom To Avoid Scratches On The Floor. The Seat Size Shall Be 510±10 Mm(D) X 1040±10 Mm(W), Seat Height = 435±10 Mm, Overall Width = 1360±10 Mm, Overall Depth = 770±10 Mm & Overall Height = 800±10 Mm. Dimensions Tolerance + 20 Mm. , Centre Table For Cabin 3 - Providing And Supplying Centre Table With An Overall Size 1200Mm X 600Mm X 430Mm. The Top And Side Cladding Shall Be Made Up Of 36Mm Thick Pre-Laminated Particle Board Of Grade Ii Of Is 12823 With Approved Laminate And Finish As Per Approved Shade. Extruded Aluminium Section Shall Be Inserted Within Side Corner Edge At Both Side Of The Table. There Shall Be Leveller Shoe Provided At The Bottom. Dimensions Tolerance + 20 Mm. The Participating Brand Must Have All The Prevalent Quality & Safety Related Certifications Like Iso: 9001, Iso:50001, Iso:14001 & Iso: 45001 By Nabcb, Bifma Membership, Aiota & Greenguard Certification Has To Be Submitted. , Corner Table For Cabin 3 - Providing And Supplying Centre Table With An Overall Size 600Mm X 600Mm X 430Mm. The Top And Side Cladding Shall Be Made Up Of 36Mm Thick Pre-Laminated Particle Board Of Grade Ii Of Is 12823 With Approved Laminate And Finish As Per Approved Shade. Extruded Aluminium Section Shall Be Inserted Within Side Corner Edge At Both Side Of The Table. There Shall Be Leveller Shoe Provided At The Bottom. Dimensions Tolerance + 20 Mm. , Wooden Almirah For Cabin Faculty Room & Hall - Supplying & Placing Storage Unit With An Overall Size 900Mm X 450Mm X 2000Mm. Storage Shall Be Made Up Of Pre-Laminated Particle Board Of Grade Ii Of Is 12823 With Approved Laminate And Finish As Per Approved Shade. All Profile I.E. Side, Back, Top, Shutter, Skirting Shall Be 18Mm Thick And The Edges Shall Be Sealed With Thin Strip Of Impermeable Pvc That Is Cut To Fit The Size Of Board Panel And Duly Pasted With The Assistance Of Edge Banding Machine At 200 Degree Celsius. The Storage Shall Have 3 Nos. Of Adjustable Shelf And 1 Fixed Shelf. 2 Normal Shutter And 2 Glass Shutter Shall Be Provided For Closing And Opening The Shutter. The Glass Shutter Shall Be Made 4Mm Clear Glass Insert Within Aluminium Profile. The Shutter Shall Be Operated With Concealed Crank Hinge With Ss Handle As Well As Mp Lock Mechanism. To Protect The Wall From Kicks, Abrasion And Serve As A Decorative Moulding, Skirting Shall Be Provided At Bottom. There Shall Be Buffers Provided At The Base To Avoid Scratches On The Floor. Dimensions Tolerance + 20 Mm. , Steel Almirah For Cabin Faculty Room & Hall - Providing, Supplying And Placing Steel Almirah In Perfectly Upright And Straight Position. The Overall Size Of The Almirah Shall Be 915Mm (W) X 485Mm (D) X 1980Mm (H) Including Legs. It Should Be Supplied With 4 Nos. Of Adjustable Shelves I.E. 5 Loading Compartments. All Components Shall Be Made Of 0.8Mm Thick High Yield Strength Crca Sheet Of Grade ‘D Confirming To Is: 513. Stiffeners Shall Be Provided In Shelf & Door. The Steel Hinged Door Shall Be Provided With Locking Mechanism Which Is Assembled With Bolt Arrangement. The Shelves Shall Have Folded Constructions Which Have Intrinsic Rigidity And High Load Carrying Capacity. Uniformly Distributed Load Capacity Per Each Shelf Shall Be 40Kg Maximum. The Complete Steel Structure Shall Be Constructed By Welding And Provide Finishing With Epoxy Polyester Powder Coated To Be Thickness 50-60?. Dimensions Tolerance + 20 Mm. , Steel Bookcase For Cabin & Faculty Room - Providing And Supplying Metal Book Case With An Overall Size 915 Mm (W) X 320 Mm (D) X 1750Mm (H). The Book Case Shall Be Supplied With 4 Nos. Of Individual Compartments. All Components Shall Be Made Of 0.8Mm High Yield Strength Crca Sheet Of Grade ‘D Confirming To Is: 513. Each Door Shall Have Individual Locking Provision And 4 Mm Thick Transparent Glass For Clear Inside Vision Secured In A Metal Frame Through Rubber Gasket. Each Door Shall Have Scissor Mechanism For Receding Inside The Top Of Respective Compartment Which Ensures Parallel & Smooth Movement. Each Door Shall Have Plastic Side End Caps As Handle Which Is Easy To Grip. Each Compartment Has A Storage Shelf Having Uniformly Distributed Load Capacity Of Each Shelf Is 40 Kg Maximum. The Finish Is Epoxy Polyester Powder Coated To The Thickness Of 40-60?. Adjustable Leveler Shall Be Provided With Metal Insert To Resist Scratches On The Floor And Also Level & Support Structure.Dimensions Tolerance + 20 Mm. , Visitor Chair For Cabin & Faculty Rooms - Providing And Supplying Visitor Chair With Ergonomic Design For User Comfort. The Seat And Back Shall Be Made Of Hot Pressed Commercial Plywood Padded With High Resilience Polyurethane Foam Having Density 40Kg/M³ In Seat And 32Kg/M³ In Back. The Same Shall Be Upholstered With Leatherite Tapestry 0.8Mm Thick. The Backrest Of The Chair Shall Be Made By Keeping The Natural Curvature Of The Spine For Lumbar Support With The Assistance Of Cushion. The Armrest Shall Be Cushion Arm With Leatherite Covering. The Frame Structure Shall Be Cantilever Support Type Made Up Of Ms/Crca Chrome Plated Circular Pipe Having Dia. 28.6Mm. There Shall Be Co-Polymer Polypropylene Shoe Provided At The Base To Avoid Scratches On The Floor As Well As Uneven Surfacing. The Seat Size Shall Be 480±10 Mm(W) X 460±10 Mm(D) And Back Size Shall Be 460±10 Mm(W) X 580±10 Mm(H) From Seat & Overall Height = 1020±10 Mm, Overall Width = 610±10 Mm & Overall Depth = 670±10 Mm. Dimensions Tolerance + 20 Mm. , Modular Conference Table - Supplying & Placing Conference Table In Completely Knock Down Conditions With An Overall Size 2400Mm X 1200Mm X 750Mm That Is To Be Assembled At Site. The Table Top Shall Have Same Size Made Up Of 25Mm Thick Pre-Laminated Particle Board Of Grade Ii Of Is 12823 With One Side Laminate And Finish As Per Approved Shade. The Table Top Profile Shall Be In Rectangle Shape And The Edges Shall Be Sealed With 2Mm Thick Thin Strip Of Impermeable Pvc That Is Cut To Fit The Size Of Board Panel And Duly Pasted With The Assistance Of Edge Banding Machine At 200 Degree Celsius. Single Sided Flapper Box Shall Be Enclosed At Table Top That Houses Video, Audio, Data And Power Connection Discretely. The End Wall Of The Table On The Side Shall Be Topped By Gable End. The Gable End Shall Have The Size 900Mm X 570Mm. The Gable End Shall Be Made Up Of 25Mm Thick Pre-Laminated Particle Board And Profile Shall Be In Linear Shape With Appropriate Pvc Edge Banding. The Table Shall Be Clad With 18Mm Thick Modesty Panel Which Provide Structural Support For The Table. The Modesty Panel Shall Be 18Mm Thick Pre-Laminated Particle Board With Appropriate Pvc Edge Banding Connected With Both End. The Table Shall Be Supported On Ss Pipe Leg 202 Grade. It Shall Have Cross Section Area 80Mm X 20Mm. There Shall Be Buffers Provided To Avoid Scratches On The Floor. The Table Connections Have To Be Made In Such A Way That No Gap Should Be Seen In Between. Table Shall Be Provide A Flip Up/ Pop Up Box (Without Wires) 01 No. Dimensions Tolerance + 20 Mm. , Main Chair For Conference Table - Providing And Supplying A High Back Chair With Ergonomic Design, Comfortable & Aesthetically Appealing. The Seat And Back Shall Be Made Of Natural Wood And Combination Of (18+6)Mm Thick Double Layered Moulded Commercial Plywood Padded With High Resilience Polyurethane Foam 70Mm Thick Having Density 40Kg/M³ In Seat And 70Mm Thick Having Density 32Kg/M³ In Back. The Same Shall Be Upholstered With Leatherite Tapestry 0.8Mm Thick And 535 Gsm. The Backrest Shall Be Made By Keeping The Natural Curvature Of The Spine Which Helps To Provide Lumbar Support As Well As Head Support. The Chair Shall Be Supplied With Polypropylene Chrome Cushion Arm With Leatherite Covering Top Pivot Joint With Back. For Seating Durability The Chair Shall Have Torsion Bar 360 Degree Revolving Mechanism With Upright Position Locking And Tilt Tension Adjustment. The Pneumatic Seat Height Adjustment For Healthy Seating, User Can Adjust Seat Height Up To 65Mm With Bifma Standard Class-3 Gas-Lift To Suit Them Using The Lever Under The Seat. The Gas-Lift Mechanism Should Be Tested As Per Ansi/Bifma X5.1-2011 Standards. The Pedestal Should Have Five Legged Injection Moulded Polypropylene With Chrome Having Pitch Circle Dia. 700 Mm Fitted With 5 Nos. Twin Wheel Castors. The Castors Of The Chair Should Be Injection Moulded In Black 30% Glass Filled Nylon, Confirming To Ansi/Bifma X5.1-2011 Standards Tested To Perform 98,000 Cycles With 250Lbs Load. The Seat Size Shall Be 510±10 Mm(D) X 530±10 Mm(W) And Back Size Shall Be 500±10 Mm(W) X 720±10 Mm(H) From Seat. Overall Height Shall Be = 1180±10 Mm, Overall Depth = 670±10 Mm & Overall Width = 710±10 Mm. Dimensions Tolerance + 20 Mm. , Chairs For Conference Table - Providing And Supplying A Medium Back Chair With Ergonomic Design, Comfortable & Aesthetically Appealing. The Seat And Back Shall Be Made Of Natural Wood And Combination Of (18+6)Mm Thick Double Layered Moulded Commercial Plywood Padded With High Resilience Polyurethane Foam 70Mm Thick Having Density 40Kg/M³ In Seat And 70Mm Thick Having Density 32Kg/M³ In Back. The Same Shall Be Upholstered With Leatherite Tapestry 0.8Mm Thick And 535 Gsm. The Backrest Shall Be Made By Keeping The Natural Curvature Of The Spine Which Helps To Provide Lumbar Support. The Chair Shall Be Supplied With Polypropylene Chrome Cushion Arm With Leatherite Covering Top Pivot Joint With Back. For Seating Durability The Chair Shall Have Torsion Bar 360 Degree Revolving Mechanism With Upright Position Locking And Tilt Tension Adjustment. The Pneumatic Seat Height Adjustment For Healthy Seating, User Can Adjust Seat Height Up To 65Mm With Bifma Standard Class-3 Gas-Lift To Suit Them Using The Lever Under The Seat. The Gas-Lift Mechanism Should Be Tested As Per Ansi/Bifma X5.1-2011 Standards. The Pedestal Should Have Five Legged Injection Moulded Polypropylene With Chrome Having Pitch Circle Dia. 700 Mm Fitted With 5 Nos. Twin Wheel Castors. The Castors Of The Chair Should Be Injection Moulded In Black 30% Glass Filled Nylon, Confirming To Ansi/Bifma X5.1-2011 Standards Tested To Perform 98,000 Cycles With 250Lbs Load. The Seat Size Shall Be 510±10 Mm(D) X 530±10 Mm(W) And Back Size Shall Be 500±10 Mm(W) X 520±10 Mm(H) From Seat. Overall Height Shall Be = 980±10 Mm, Overall Depth = 670±10 Mm & Overall Width = 710±10 Mm. Dimensions Tolerance + 20 Mm. , Discussion Table- Supplying & Placing Conference Table In Completely Knock Down Conditions With An Overall Size Dia. 900Mm X 750Mm That Is To Be Assembled At Site. The Table Top Shall Be Made Up Of 25Mm Thick Pre-Laminated Particle Board Of Grade Ii Of Is 12823 With Approved Laminate And Finish As Per Approved Shade. The Table Top Profile Shall Be In Circular Shape And The Edges Shall Be Sealed With 2Mm Thick Pvc Edge Banding. The Table Understructure Shall Be A Combination Of Ms Powder Coated And Pre-Laminated Particle Board. There Shall Shoe Provided At The Base To Avoid Scratches On The Floor. Table Shall Be Provide A Flip Up/ Pop Up Box (Without Wires) 01 No. Dimensions Tolerance + 20 Mm. , Chair For Discussion Table - Supplying And Placing Lounge Chair. The Seat Shall Be Made Of 12 Mm Thick Hot Pressed Plywood Upholstered With High Resiliance Moulded Polyurethane Foam 50Mm Thick Having Density 40Kg/M³ With Leatherite Tapestry 0.8Mm Thick 535 Gsm And The Back Shall Be Made Of Wooden Frame Upholstered With High Resiliance Moulded Polyurethane Foam 25Mm Thick Having Density 32Kg/M³ With Leatherite Tapestry 0.8Mm Thick 535Gsm. The Frame Structure Shall Be 4 Legs Support Type Made Up Of Reducing Pipe Frame Powder Coated Tubular Pipe Having Cross-Section Area Dai 19Mm Thick. The Seat Size Shall Be 430±10 Mm (D) X 450±10 Mm (W) And Back Size Shall Be 500±10 Mm (W) X 400±10 Mm (Ht) From Seat. Overall Height Shall Be = 840±10 Mm, Overall Depth = 540±10 Mm & Overall Width = 580±10 Mm. Dimensions Tolerance + 20 Mm. , Modular Workstation For Hall - Supplying & Placing Modular Workstation In Completely Knock Down Conditions With Size :- W1200 X D600 X H750/1200Mm That Is To Be Assembled At Site. The Construction Of The Main Table Shall Be Free Standing Structure. The Worktop Shall Have The Size 1200Mm X 600Mm Made Up Of 25Mm Thick Re Lam Particle Board With Laminate And Sealed With 2Mm Thick Pvc Edge Banding. A Pullout Keyboard Trey Shall Be Provided Of 18Mm Thick Plpn. Partition :- 60Mm Thick Panel Based Partition Of Height 1200Mm Having Provision Of Fabric / Soft Pin Up Board/ Laminate / Race Way. Worktop :- 25Mm Thick Plpb Board With Pvc Edge Banding. All Aluminum Parts Shall Be Pretreated And Duly Powder Coated Of 40?-50? Thick. Raceway Shall Be Provided Of Aluminum Below The Work Top As Per Requirement For Inlaying The Electrical Management And Carrying The Wire Horizontally. The Exposed Vertical And Horizontal Faces Of The Frames Shall Be Snap Fitted With Curve Trims. The Trims Shall Be Made Of Aluminum Extrusions Of Size 60X19mm With 1.5Mm Thick And Should Be Covered With Die Cast End Caps On Joints, 2 Ways, 3 Ways & 4 Ways Caps As Required. Wire Management Partition Shall Have Concealed Wire Management Capabilities And Shall Be Engineered For Responsive And Safe Operations Of Power, Telecommunications And Data (Lan) And Has Separate Components For Electrical, Data And Telephone Cables Having Adequate Capability Of Both The Vertical And Horizontal Wire Movements. Slots/Cutouts Shall Be Provided On Raceways To Fix All Electrical And Data Points. Mobile Pedestal :- (2D + 1F) 18Mm Thick Plpb Board With Pvc Edge Banding, Mobile Pedestal Shall Be Provided With An Overall Size 400Mm X 450Mm X 680Mm. Pedestal Side, Back, Top, Facia Shall Be 18Mm Thick And Drawer Base Shall Be 9Mm Thick. The Pedestal Shall Have 3 Nos. Of Drawer I.E. 2 Box Drawer And 1 Filing Drawer. The Drawer Shall Be Operated With Ss Handle And Easily Close & Open With The Assistance Of Roller Channel And Ball Bearing Channel To Enable Smooth Operation. The Drawer Shall Have Central Locking Mechanism In Which All The Drawer Shall Be Synchronized Lock With One Single Key. A Nylon Castor Based Cpu Unit Shall Be Provided With 18Mm Thick Plpb. Dimensions Tolerance + 20 Mm. , Chair For Workstations - Providing And Supplying Medium Back Chair With Ergonomic Design, Comfortable & Aesthetically Appealing. The Seat Shall Be Made Of 18Mm Thick Hot Pressed Commercial Plywood Upholstered With High Resilience Moulded Polyurethane Foam 50Mm Thick Having Density 40Kg/M³ With Foam Net Tapestry 0.9Mm Thick And 300 Gsm And The Back Shall Be Made Of Injection Moulded Polypropylene Net Cover Upholstered With Breathable Mesh Tapestry. The Backrest Of The Chair Shall Be Made By Keeping The Natural Curvature Of The Spine With Adjustable Lumbar Support. The Chair Shall Be Supplied With Injection Moulded Pu Adjustable Arm Completely Joint With Seat. For Seating Durability The Chair Shall Have Actice Bio-Synchro Mechanism With Upright Position Locking And Tilt Tension Adjustment. The Pneumatic Seat Height Adjustment For Healthy Seating, User Can Adjust Seat Height Up To 100Mm With Bifma Standard Class-3 Gas-Lift To Suit Them Using The Lever Under The Seat. The Gas-Lift Mechanism Should Be Tested As Per Ansi/Bifma X5.1-2011 Standards. The Pedestal Should Have Five Legged Made Of Die Cast Aluminium Having Pitch Circle Dia. 700 Mm Fitted With 5 Nos. Twin Wheel Castors. The Castors Of The Chair Should Beinjection Moulded In 30% Glass Filled Nylon, Confirming To Ansi/Bifma Standards X5.1-2011 Tested To Perform 98,000 Cycles With 250Lbs Load. The Seat Size Shall Be 520±10 Mm(W) X 500±10 Mm(D) And Back Size Shall Be 495±10 Mm(W) X 610±10(H) From Seat & Overall Height = 1010±10 Mm. Dimensions Tolerance + 20 Mm. The Participating Brand Must Have All The Prevalent Quality & Safety Related Certifications Like Iso: 9001, Iso:50001, Iso:14001 & Iso: 45001 By Nabcb, Bifma Membership, Aiota & Greenguard Certification Has To Be Submitted. , 2 Door Lockers For Hall - Providing And Placing In Position Personal Locker Unit Shall Be Of Dimensions 380Mm(W) X 450Mm(D) X 1800Mm(H) Having 2 Locker Unit. Each Locker Shall Have 1 Nos. Of Hanging Rod. Locking Shall Have Cam Lock With Lock Lever Plus Option. Material Shall Be Crca 0.8 Mm Thickness. Shelf Shall Be Uniformly Distributed Load Capacity Per Each Shelf Level Is 35 Kg Maximum. Finish Shall Be Epoxy Polyester Powder Coated To The Thickness Of 50 Microns. Handle/Label Holder Shall Be Aesthetically Appealing Snap Fit Abs Plastic Handle. Ventilation Shall Be Attractive Punched Pattern For Ventilation. Dimensions Tolerance + 20 Mm. , 3 Door Lockers For Hall - Providing And Placing In Position Personal Locker Unit Shall Be Of Dimensions 380Mm(W) X 450Mm(D) X 1800Mm(H) Having 3 Locker Unit. Locking Shall Have Cam Lock With Lock Lever Plus Option. Material Shall Be Crca 0.8 Mm Thickness. Shelf Shall Be Uniformly Distributed Load Capacity Per Each Shelf Level Is 35 Kg Maximum. Finish Shall Be Epoxy Polyester Powder Coated To The Thickness Of 50 Microns. Handle/Label Holder Shall Be Aesthetically Appealing Snap Fit Abs Plastic Handle. Ventilation Shall Be Attractive Punched Pattern For Ventilation. Dimensions Tolerance + 20 Mm. , 4 Door Lockers For Hall - Providing And Placing In Position Personal Locker Unit Shall Be Of Dimensions 380Mm(W) X 450Mm(D) X 1800Mm(H) Having 4 Locker Unit. Locking Shall Have Cam Lock With Lock Lever Plus Option. Material Shall Be Crca 0.8 Mm Thickness. Shelf Shall Be Uniformly Distributed Load Capacity Per Each Shelf Level Is 35 Kg Maximum. Finish Shall Be Epoxy Polyester Powder Coated To The Thickness Of 50 Microns. Handle/Label Holder Shall Be Aesthetically Appealing Snap Fit Abs Plastic Handle. Ventilation Shall Be Attractive Punched Pattern For Ventilation. Dimensions Tolerance + 20 Mm. , Lab Over Head Unit- Providing And Fixing Lab Over Head Unit With Overall Dimensions 750(W)Mm X 320(D)Mm X 675Mm(H). Over Head Unit Shall Be Welded Body With Load Bearing Members Such As Top, Bottom And Stiffeners Made Of 0.8Mm Thick Crca Sheet. The Storage Unit Shall Be Provided With A Shelf Made Of 0.8Mm Thick Crca Sheet. Each Shelf Shall Have Load Carrying Capacity Of 30-40 Kgs. Mp With 180 Degree Cam Lock. Semi Recessed Handle And Ss Hinge. Shutter Shall Be Provided With A Mp Lock. , Laboratory Lab Stools- Providing And Placing In Position Ht. Adjustable Stool With Back. The Seat Shall Be Made Up Of 1.2±0.1Cm Thick Flat Plywood And With Moulded Polyurethane Foam And Are Upholstered With Replaceable Synthetic Leather Covers. The Dimensions Of Seat Shall Be Diameter 40.0 Cm And Adjustments Are 360° Revolving Type. The Back Foam Shall Be Designed With Contoured Lumbar Support For Extra Comfort. The Upholstery Shall Be Available In Synthetic Leather. The Dimensions Of Back Shall Be 45.0 Cm (W) Covered With Polyurethane Foam. The Hr Polyurethane Foam Shall Be Moulded With Density = 40 +/-2 Kg/M3. The Five-Prong Pedestal Shall Be Fabricated From 0.2 ± 0.02 Cm Thick Hr Sheet ( Is : Dd 1079/ Hr ), Powder Coated ( Dft 40-60 Microns ). The Twin Wheel Castors Shall Be Injection Moulded In Black Nylon. Dimensions Tolerance ±20 Mm.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
Jammu And Kashmir View Result →
37.
Housing Urban and Rular Development #11221367 AOC
Tender For Construction Of New School Building For Upgradation From Secondary To Higher Secondary School Under Samagra Shiksha, Assam At Luitporia Missing High School, Jorhat District. (Furniture Works) , Additional Classroom: Desk Cum Bench: Overall Dimension 1800 X 850-900 X 740-750. Desk 1000 X 378 X 750 Mm. Bench 1800 X 335 X 437Mm. The Height/Depth Of The Backrest Should Be 265 Mm. The Desk, Seal & Backrest Should Be Made Of 18 Mm Thick Pre Laminated Mdf Board Isi Marked With Laminate Pasted On Top And Edges With Machine Pressed Pvc Edge Bading Sealed With Hot Melt Eva Glue. The Understructure Should Be Made Of 25.4 X 25.4 X 1.2 Mm Thick 60-70 Micron Epoxy Powder Coated Ms Tubes. Storage Shelf Should Be Made Of 0.6 Mm Thick Powder Coated Affixed Below The Desktop. The Front Side Covered With Modesty Panel Mode Of 1Mm Thick Crca Ms Steel Of Size 1800 X 150 (H) Mm & Edges Sealed With Pvc Bands With Provision Of Two Metal Hooks For Hanging School Bags Fixed At Ends. Make: Godrej/Wipro/Nilkamal/Brahmaputra Automobiles Pvt.Ltd/Methodex/ Any Other Reputed Brand Approved By The Department. , Teachers Table: Table Dimension 900 X 600 X 740-750Mm With One Drawer. The Table Top Made Of 19Mm Mdf Board Isi Mark With 1Mm Laminate Pasted On Top With Edge Rounded And Machine Pressed & Sealed With 2Mm Pvc Band Sealed With Hot Melt Eva Glue. The Under Structure/Frame Will Be Of Tubular Frame Of Square Tubes Size 25.4 X 25.4 X 1.2Mm Thick Powder Coated With 60-70 Micron. The Shell Of Drawer Is To Be Made Of 0.5Mm Thick Crca Ms With Metal Lock. Make: Godrej/Wipro/Nilkamal/Brahmaputra Automobiles Pvt.Ltd/Methodex/ Any Other Reputed Brand Approved By The Department. , Teachers Chair: Chair With Arm Made Of Natural And Biodegradable Material With Seal & Back Made Of Polyurethane Foam Covered With Fabric. The Dimension Of The Chair Shall Not Be Less Than The Following: 1.Overall Height: 850Mm 2.Seating Height:455Mm 3.Width:540Mm. Depth:500Mm Make: Godrej/Wipro/Nilkamal/Brahmaputra Au
Contract Date: Jun 04, 2026 Contract Value : 31.09 Lakh
Government Departments No of Bidders 3
39.
Rural Development #11215579 Technical Bid
Tender for Rate Contract Of Miscellaneous Item For Financial Year 2026-27 At Gr Anchayat Jaweli Khu. Tah. Etapalli , Items , Hand Wash Station Set 90 Mm Pipe,70Mmpipe ,Basing Plate ,Albo75 Mm Clamp Wicer ,Gi Structure Stand , Complete Installation. , Bleaching Powder , R.O. Machin And Water Purifier Complete Set , Submersible Machine 1 Hp , 20 Mm Pipe Water Cooler And Purifier Candle , Bluestar Water Cooler 60 Ltd , Solar Submersible Pump Complete Setup ..Solar Submersible Pump 1 Hp Lubi ,Pannel 250W 4, Stand ,Dc Controller , Structure And Complete Installation .. , Zp School Complete Electric Fitting , Sanatary Napkin Machine , School Complete Game Set Cricket Kit, Football Kit, Volleyball Kit, Batminton Set, Dumbbells, Carrom, Tape, Visual, Band Set, Ruberping ,Mating 4 Fit, Dress Girls And Boys , Led Light 18 W Crompton , Led Light 15 W Crompton , Led Street Light 36 W Crompton , Nut Bold, Clamp, Pipe , Wire, Tapeset, Holder ... , Men Switch Crompton , Handicap Revolving Chair 3 Wheel .... , School Painting Chart, Toy Chart, Wall Painting Chart , Animal Chart ... , Color Printer Nipex , School Projector Digital Setup Projector Cromcast Tv Streaming Device By Google ,Project 4*6 Stand Zebronics Home Theater Zeb 7500 , Ceramic Board 4×6,Hp All Tomy Web Cam , Complete Installation . , Ahuja Sound Service Setup... Ahuja 250 W Amply ,Bhonga 2, Unit 2 Ahuja , Mike 2 Ahuja Box 15 2.. , Solar Inverter Setup Amaron... Amaron Tecno Xp 2300Power Inverter Battery 150 Ah , 3 Years Warranty Digi Power And Complete Installation , Mobile Tab , Lamination Machine , Rain Water Harvesting Setup ..90Mm Pipe ,1000 Ltr Dram 2 , 75Mm Pipe , Lbo , Clamp Gi Structure And Complete Installation , Solar Pump Setup 1 Hp Submersible Pump, Pannel 250 W ,4 Stand , Dc Controller, Structure Gi. Complete Instruction , Laptop..Dell Company , Computer Setup Keyboard , Mouse , Cable Cpu, Monitor , Z P School Exercise And Games Set.. See Saw, Football Kit, Sliders, Palna, Volleyball Kit Cricket Kit , Batminton Kit , Skip Rope , Dumbbells, Gola, Bhala , Tape, Dress, Carome ,Chairs , Lazim , Z P School Solar Electric Setup.. Amaron Solar Inverter 1000 W , Pannel Structure , Tubular Inverter , Battery 150 Ah, 3 Years Warranty Metal Stand , Gi Structure Cable 4Mm , Complete Electric Fitting ...25 Ltr Ro System , Strature Wheel Alien , Chair Wc 9404 Model , Chair S Model 1324 Model , Office Locker 4.5 Fit , Chair Wc 9404 , Chair S Model 1324 , Office Locker 4.5 Fit , Apsara Office Locker 5 Fit , Office Karishma Table 4 Fit , Computer Table 3 Fit , Revolving Chair Mii , Folding Chair , Cement Benches , Cement Dust Box , Plastic Dust Box 3 Fit Wheel , Ceiling Fan Crompton , Ceiling Fan Dc , Matting , N-95 Mask 3 Fly , Sanitizer 50 M , Savlon Hand Wash Lotion 100 Ml , Solar Highmast Set 300 W Pannel , Structure, 6Meter Gi Pole , Ring ,Dc Flood Light 6 ,300 W , Cable 4Mm Complete Installation , 1Hp Solar Dual Pump , Solar Kandil , Led Tv 42 Nipex 4K , Sanitizer Machine Fogging Portable Touch Lense Capacity 3 Ltrs 3 Years Warranty , Black Board , Solar Street Light 60 W Entrix ..Solar Led Street Light Pole 15 Fit Street Light 60 W ,Solar Panel .60 W ,Lithium Battery 64 Ah Complete Installation , School Uniform , Ghanta Gadi , Anganwadi Uniform , Anganwadi Sahitya Drum ,Koti,Ganj,Tat,Wati,Gund,Chamach ,Samai,Glas,Kadai,... , L.E.D.Highmast Light Complete Setup And Full Installation... Author Photos , Led Street Light 36 Watt , Rudra Jal , Decorating Items , Electric Digital Starter , Nilkamal Chair , Solar Street Light , Ac Street Light , Cement Benches , Community Dustbin , Measurement Tape 30M , Measurement Tape 50M , Paper Ream
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
40.
Power #11206303 Price Bid
Tender for Contract For Supply Of Key Materials Required For Maintenance Of 33/11Kv Receiving Stations Along With Their Lines Under The Jurisdiction Of Std Bijbehara During The Year 2026-27 , Electrical Store/Workshop Items/: As Per Is Standards , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Incommer) As Per Technical Specifications Of Rec Std , 11 Kv Vcb Panel Board 12 Kv, 1250A, 25 Ka, Outdoor (Outgoing) As Per Technical Specifications Of Rec Std , 33 Kv Vcb (36 Kv, 1250A, 26.2 Ka, Outdoor Type) As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv C&R Panel With Nemurical Relays With Out Differential Relay ( Iec 61850), Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant As Per Technical Specifications Of Rec Std , 33 Kv Isolator With Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Isolator Without Earthing Blade (36Kv,1250A, Outdoor, 3 Poles, 25 Ka) , 33 Kv Outdoor, Oil Cooled, Live Tank, Single Phase , 3 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection,0.5 For Metering & Ps For Differential With Ratio 800-400/5-5-5A ,600-300/5-5-5A , 500-250/5-5-5A, 400-200/5-5-5A (Per Set Of 3 Pieces) , 33 Kv Outdoor, Oil Cooled, Copper Wound , Single Phase , Pt Set With Rated Primary Voltage 33000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 (Per Set Of 3 Pieces). , 33 Kv Lightening Arrestors (30 Kv, 10Ka, Station Class, Zno, Porcelain/Polymer) Gap Less(Per Set Of 3 Pieces). , 33 Kv Post Insulator (Polymer/Porcelain 36Kv, 170Kv Impulse) , Galvanised Steel Structures(6 G I Pipe With Top,Base & Grouting Bolts) As Per Rec , 11Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 11Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 2.5 Sqmm 2 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 4 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 6 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 2.5 Sqmm 8 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , L T Cable 3 1/2 16 Sq.Mm Core Armored , Al Conductor Sheathed Pvc Insulated (Std Make) , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Or Raychem Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Indoor 120Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 400Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 300Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 240Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 185Sqmm , 11Kv 3 Core Cable End Termination Kits Of Sizes,Heat Shrinkable Of 3M Std Make Required For 3 Core Xlpe Cables, Including Required Size Of Lugs/Thimbles, As Per Isi Specification Outdoor 120Qmm , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 3 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 630 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Outdoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 400 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 300 Sqmm; Indoor , 33 Kv 1 Core Cable End Termination Kit Of Sizes , Outdoor 3M Std Make , Heat Shrinkable Including Required Size Of Lugs/Thimbles ,As Per Isi Specification 240 Sqmm; Indoor , 11 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb, Electric Field, Sudhir Or The Like , 11 Kv Indoor Type,Dry,Resin Cast, Single Phase , 2 Core Ct Set As Per Isi Specification With Accuracy Class Sp 10 For Protection & 0.5 For Metering Preferably Of Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make Having) With Ratio 800-400/5/5,600-300/5-5,400-200/5-5 (Per Set Of 3 Pieces). , 11 Kv Indoor ,Dry, Copper Wound , Three Phase , Pt Set In Ms Enclosure With Rated Primary Voltage 11000/√3 & Rated Secondary Voltage 110/√3 As Per Isi Specification With Accuracy Class 0.5 , 11 Kv Lightening Arrestor Set( Station Type),Outdoor, Metal Oxide Gapless As Per Isi Specifications.(Per Set Of 3 Pieces). , Digital Protection Relay Non-Communicable Model Type 141A (Ashida/Er Make) 3 O/C +1 E/F For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make . Auxillary Voltage 30V Ac/Dc Confirming To Iso 9001:2008 Standards. , Master Trip Relay 24-50V For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make. , 36V , 200Ah Battery Bank (Comprising Of 3 No Batteries Of 12 V Each) Conforming To Iec60896-21/22, Lead Acid Type Of Exide Make , 36 V,200 Ah , Float-Cum-Boost Battery Charger,Copper Wound,Air Cooled, With Full Wave Rectification With Heat Sink & 40A Diodes, Ae Make Measuring Instruments, 16Swg Steel Body Sheet, For 15A,220 V, 1Phase, 50 Hz Ac Input Supply Along With Ac/Dc Terminal & Earthing Slot, Correction Time 10Sec, Std Make , 5Kva Servo Motor Control Voltage Stablizer With Input 100V & Output 220V,Air Cooled,50 Hz,16Swg Steel Body, Copper Wound , Correction Time 10 Sec, Std Make , Auxillary Switch Suitable For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Panel Bush For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Bush(Bus Bar Spout) For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Interruptor Housing For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Limit Switch For 11Kv Vcb Panels Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Or The Like , Breaker Contact/Female Contact For 11Kv Vcb Switch Gear Like Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir Make , 36V Tripping Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field, Sudhir Or The Like , 36V Closing Coil For 11Kv Vcb Breaker Like Easun Reyroll, Allind, Alsthom, Crompton Greeves, Electric Field Sudhir Or The Like , Digital Ammeter/Voltmeter (Programmable)For 11Kv Vcb Panels , Panel Indicators , Ammeter Selector Switch Of 11Kv Vcb , Tnc Switch Of 11Kv Vcb , Spring Charging Motor Of 11Kv Vcb Breaker , Spring Charging Motor Of 33Kv Vcb Breaker , Gears For 11Kv Vcb Of Different Make(Big) , Gears For 11Kv Vcb Of Different Make(Small) , Dc Delco Motor For 33 Kv Vcb , Dc Delco Motor For 11 Kv Vcb , Transormer Oil As Per Is For Power Transformers,Cts,Pts Etc , Distilled Water For Battery Bank , Almunium Alloy Clamps Of Sizes Like Ct,Pt,Pad,Isolator,La,T Etc For 100/200Mmsq Acsr , 33 Kv Vaccum Interruptor Confirming To Iec62271-100, Gb 1984-2003 Standard Having Current Carrying Capacity 1250 Amps Suitable For Bhel,Crompton Greeves,Alsthom,Abb,Megawin,Sudhir Or The Like , 33K Vcb Bushe Complete Assembly Confirming To Is:2099 Standard , 33Kv /11 Kv Bushes Of Power Transformers Complete Assembly Confirming To Is:2099 Standards , 11Kv/ Lv Bushes Along With Bush Rods Of Auxillary Transformers Complete Confirming To Is: 2099 Standards , 33Kv P.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bushes With Complete Assembly Confirming To Is:2099 Standards , 33Kv C.T Bush Rod , 33Kv Isolator Grovees(Knife/Tubular Type) Complete , Almunium Tubular Bus Bar As Per Rec , 11Kv G.O Set 400 Amps , 11Kv Isolator, Double Break,3-Pole, 600Amp, Horizental Mounting Type, With Earth Switch. , 11Kv Link Set,Copper Knife(50X6x450)Mm,400 Ampers, Complete With Clamps , 33Kv Link Set,Copper Knife (50X8x600)Mm,800 Ampers, Complete With Clamps Heavy Duty , 33Kv Do / Fuse Set , Distribution Panel (30V, Dc) With 1 No.10Amp. Mccb. Double Pole For Battery Incoming Supply With Dp Mcbs & Indicating Lamps Etc. , Distribution Panel (415 V, Ac) Complete With Ckt. Breakers, Indicating Lamps Etc. , Led Lamps Of Control Room Building ( 9-15 Watts) , Led Lights For Yard( 50 Watts) , Almunium Paint , Red Oxide Paint , Almunium Thimbles Of Sizes(120-600 Sqmm) , 11 Mtr Long S.T Poles (410Sp- 56) Complete With Base And Cap As Per Rec Standard And Specifications , 9 Mtr Long S.T Poles (410Sp- 33) Complete With Base And Cap As Per Rec Standard And Specifications , 13 Mtr Long S.T Poles (410Sp- 69) Complete With Base And Cap As Per Rec Standard And Specifications , 0.2 Acsr (Panther) Conductor , 0.15 Acsr (Wolf) Conductor , 0.1 Acsr (Dog) Conductor , 0.05 Acsr (Rabbit) Conductor , Fabricated Galvanised V -Type Channel Iron X-Arm,6-10 Long Ch Iron,Channel Iron Top,Angle Iron Belts, Clamps & Flat Braces Etc As Per Rec Standard For 33/11Kv Lines. , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm , 33 Kv Polymeric Composite Disc Insulator 36Kv,Min Failing Load 70Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Suitable For 0.1 Acsr Conductor , P G Clamps For 200/150/100Mm Sq Acsr , 33 Kv Danger Plates With Clamps , Anticlimbing Devices With Clamps , Gal Nuts & Bolts With Washers , Earthing Complete By G I Pipe 40Mm Or G I Rod 20Mm 2.5 Mtr Long Through G I Strip As Per Rec Standard , Galvanised Stay Set With 50X8mm Stay Clamps,Guy Insulator,Anchor Plat(300X300x8)Mm,Nuts/Bolts ,Turn Buckle,1.8 Mt Long 20Mm Dia Sold Gs Stay Rod & 7/4.0Mm Dia Gi Std Wire Complete , Guard Netting As Per Rec Standard , Galvanised Spiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard , Porceline 70 Kn Disc Insulator , Porceline 45 Kn Disc Insulator , Porceline 33Kv Insulators (10 Kn) , 33Kv G.I Pins With All Accessories Weighing 2700 Gms , 33Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , 11Kv Rubber Gloves For Protection Of Electric Shockproof Insulated Hand Rubber , Electrical Insulating Rubber Mat 6Mm Thickness(1Mrx2mtr). , 63 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , 100 Kva ,11/0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, (Aluminium Wound Upto 200Kva, Copper Wound For 250Kva Or Higher Kva Ratings) , And With Lv Cable Box Having Detachable Aluminium Gland Plate , Digital Three Phase Voltmeter , Porceline 11Kv Insulators , 11 Kv G.I Pins With All Accessories , Coper Bus Bar , Drill Bilts Of Sizes 3/4 And 1 , Hexa Blade , Round Hexa Blade , Welding Rods , Bush Rods For 10Mva, 6.3 Mva , Monoplastic Tape Rolls , 11Kv Pannel Hrc Fuses , Ac/Dc Mccb Of Different Ratings , Oil Temperature Indicator Of Reputed Make For 33/11-6.6Kv Power Transformers , Winding Temperature Indicator Of Reputed Makefor 33/11-6.6Kv Power Transformers , Standard Quality Silica Gel For Various Capacity 33/11Kv Power Transformers , Breaker Mechanism Of Reputed Make , 33Kv Polymeric Composite Pin Insulator 36Kv,10Kn,Lighting Impulse 170Kv Positive & 180 Kv Negative,Creepage Distance 900Mm Sauitable For 0.15/0.2Acsr , 2.5 Sqmm 12 Core Control Cable Armored , Copper Conductor Sheathed Pvc Insulated Multi Colour Voltage Grade 1.1 Kv (Std Make) , 33Kv Grade, 1 Core Heat Shrinkable Jointing Kit, Including Required Size Of Lugs/Thimbles, As Per Relevent Is Specification 7098 (Part-Ii) 3M/ Raychem Suitable For 630/400/300Sqmm , Buchholz Relay For 33/11-6.6Kv Transformer Protection , Twin Bimettalic Clamps Aaac Equivalent 8 Bolt Type With Four Outputs As Per Relevant Is Standard Suitable For 01/0.2Acsr , Ht Tape Roll As Per Is Standard With Latest Ammendments , Indication Lamps Suitable For 33/11Kv Panel Board Ike Bhel/Crompton Greaves/Alsthom/Allind /Er Make Electric Field/ Sudhir / Pascal/Hartek Make , Monoplast Tape As Per Is Standard With Latest Ammendments , Lt Insulation Tape As Per Is Standard With Latest Ammendments , Old Sarees , Earthing Electrodes As Per Is Standard With Latest Ammendments , 11Kv Auxillary Relays. , Al Alloy Tension Fittings Suitable For 50/100/150/200 Sqmm Acsr As Per Rec , Almunium Folded Ladder , Bus Bar Type Clamp For Connecting Ic Cable Outdoor , Water/Snow Resistant Shoes (Tsf Make Or Any Equivalent Brand) , Rain Coat Long Size Over Coat Type (Size 4Xl) , Umberlla Big Size , Safety/ Industrial Helmet With Straps Isi Mark, With Head Lamp Bracket And Detachable And Interchangeable Led Headlamp Alongwith Charger/Charging Facility(Color:- White , Blue And Yellow ) , Chainsaw Cutter Heavy Duty 1800-2500 W , Chainsaw Cutter Heavy Duty (Portable) 1000-1500W , Searchlight Heavyduty (Eveready, Panasonic/Philips Or Equivalent) , Heat/Flame Gun Metallic For Cable Kit Shrinking With Portable Butane Gas Can 225G Of 01No. , Butane Gas Cartridges/Canisters, Refill Fuel For Welding Torch, 225G , Electric Heat Gun For Cable Kit Shrinking 1000-200 Watt , Heavy Duty Tool Kit (Flat/Round Spanner Set, Plier, Screw Driver Set, Wire/Cutter/Striper, File With Torque Spanners Set Etc Complete Set) , Al. Ladder Foldable 2X20 Ft. Telescopic Portable Ladder , Digital Megger 5 Kv , Digital Megger 2.5 Kv , Cork Sheet 4Mm , 2V Battery 100Ah Vrla Type Of Standard Make , 2V Battery 200Ah Vrla Type Of Standard Make , 12V Battery 200Ah Lead Acid Type Of Standard Make , 33 Kv Current Transformer Outgoing/Incomer (33 Kv, 1Φ, Multi Ratio Multi Core 600-300/1A, Indoor Type) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted At Pahalgam , 11 Kv Current Transformer Outgoing (11 Kv, 1Φ, Multi Ratio Multi Core 200-400/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station Panel Mounted (Pahalgam) , 11 Kv Current Transformer Incommer (11 Kv, 1Φ, Multi Ratio Multi Core 900-600/1A, Indoor) (1 No. Per Φ) For Gis Compatible 33/11Kv Station (Pahalgam) , 33 Kv Single Core Indoor Cable Kit ( Plug In Tremination Type And Screened Seperable Connectors ) For 400 Mmsq Cable For Gis Compatible Substaion (Brand:- Euromold, Nexans, Raychem Etc) , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 33Kv 1Corex400nmsq,Nndia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Plug-In Termination Kit (C Bushing Elbow Connector) To Suit 11Kv 1Corex 400Mmsq,Ins Dia:39.0-48.5Mm Model:-M484tb/G, Complete Set Of 3 No.S With All Accessories Including-(3Boot+3 Mechincalconnectors) Of Standard Make For Gis Compatible Substation , Inner Core Plug In Termination Kit To Suit Size-3-Lcx630mmsq 12/20(24Kv) installation Dia: 34.0-45.06 Complete Set With All Accessories Per Set Of 3Nos Of Standard Make Gis Compatible Substation , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,3-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,630 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,400 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 300 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium,240 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 185 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 33Kv (E) Grade Armoured ,Almunium, 120 Sq Mm,1-Core,Xlpe Power Cable, (Std Make) , 11Kv 3 Core Cable Jointing Kit Of Sizes 185/240/300/400 Sqmm , 11Kv 1 Core Cable Jointing Kit Of Sizes 185/240/300/400/630 Sqmm , ⁠630 Mmsq Hydrolyic Crimping Tool , ⁠Electric Grinder 700 To 1000 W Of Standard Make , Electric Digital Welding Machines (Portable Of 100 - 250 Amps , 11Kv Cable Jointing Kit , Oil Pump Manual Of Standard Make For Transformers , Foam Spray Sealant Tins Of 450Ml , Vaseline/Grease , 11Kv Cts Of Different Ratios And Make Like Electricfield, Pasxcal, Sudhir, Stelmac Etc.) , T Clamps For Acsr 200Mmsq , Retaining Pins, Lock Nuts Of Sizes, External Retaining Rings(Rotor Clips, E Clips, C Clipso/S, Split Pins/Cotter Pins O/S , Single Phase 1 Hp Water Motor Of Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
41.
Public Administrative Department #11198050 AOC
Annual Plan-Anthikad BP 2025-26 : Renovation of Alappad CHC-Pro.no.65-General Civil Work-- 1 MAINTENANCE 2 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 3 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 4 21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 5 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 6 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 7 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar 8 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below 9 OD185135/2025-2026:Supplying and fixing Pressed Steel Windows and Ventilators of standard pattern with frames (with steel shutter) as per profile of sections 82*62mm, 12mm dia. rod, 25*5mm flat with 75mm MS hinges, 50mm MS hook, 125mm MS stay and handle for windows with section 105*60mm without steel shutters, made of sections 75*30mm for outer styles and horizontal members and then inserted with enclosed and stiffened sheet 26CR with zinc chromate primer.( Data derived for 150*150 cms panelled window) 10 10.29.1:Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides 11 15.23.2:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm 12 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 13 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 14 OD185137/2025-2026:Supplying and fixing Stainless steel floor trap including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 15 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 16 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 17 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet 18 15.28.1:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet 19 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 20 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 21 OD185139/2025-2026:Roofing with G.I hard colouur powder coated traffod sheets 0.35 mm thick or nearest available thickness with overlaps of 150 mm at ends and GI hook or crank C.I. bolts and nuts including plain washers and bitumen washers etc complete 22 OD243391/2025-2026:Providing & fixing Poly carbonate plain sheet 2mm thick as approved by the Engineer incharge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDMseal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost ofpurlins, rafters, trusses, and including cutting to size and shapes where ever required 23 OD187993/2025-2026:Plain G I ridge capping 225 mm flaps with 0.35mm thick /nearest available size SS screws including plain washers plain washers and bitumen washers etc. complete 24 OD185134/2025-2026:Supplying and fixing 150 mm dia half cut section with brackets at the ends of sheet or tiled roof for rain water collection including all cost of material etc . 25 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) 26 OD185136/2025-2026:welder for welding works 27 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 28 OD185143/2025-2026:Engaging man coolies 29 50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 30 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 31 50.18.8.7.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2 32 50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 33 50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 34 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow 35 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee 36 50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 37 OD185175/2025-2026:Supplying and fixing 20mm thick ready made PVC door (75*200cm) with frame 50*42 mm including conveyance,cost of fitting , labour for fixing etc. 38 OD185176/2025-2026:supply of 20mm PVC Tap 39 OD185177/2025-2026:Carpenter For repairng Doors & WIndows 40 OD198066/2025-2026:Taking out existing interlocking paver blocks , including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in Charge.(Modified data 16.83) 41 OD198218/2025-2026:Laying cement concrete interlocking paver blockover50 mm thick compacted bed of 6mm aggregate , filling the joints with fine sand etc all complete as per the direction of Engineer-in- charge. modified data 16.68 (departmental interlock tile) 42 Drain 43 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 44 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 45 OD198111/2025-2026:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br>II. P.C.C grade M 15 <br> (i) Nominal mix (1:2.5:5) 46 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 47 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 48 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 49 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 50 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) 51 Compound wall 52 15.10.2:Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually / by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge:In cement mortar 53 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 54 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 55 OD198662/2025-2026:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc complete as per direction of Departmental officers at site 56 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 57 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 58 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 59 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 60 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). 61 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Contract Date: Jun 01, 2026 Contract Value : 21.15 Lakh
Government Departments No of Bidders 1
42.
Educational and Research Institute #11191898 Price Bid
Tender for Civil Work , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site Ne , 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.7 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) , 5.22.6 Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or Moree , 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 22.5 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 50.13.1 9 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete , 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding , 11.49.2 Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tiles 600X600 Mm , 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm , 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.20.1 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Light Shade Pigment Using White Cement , 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , 5.30 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.2.2 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) , 9.117.1 Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below (Tolerance ±1 Mm), With Wall Thickness 2.0Mm (±0.2 Mm), Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 48X40 Mm , 9.118.2 Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride (Pvc) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised/Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm (± 0.2 Mm) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic/Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece , 22.23.2 Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerin Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Horizontal Surface One Coat @1.10 Kg Per Sqm. , 13.26 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete , 13.48.1 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Two Or More Coats Applied On Walls @ 1.25 Ltr/10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr /10 Sqm , 13.48.3 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture , 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Od398633/2025-2026 Supplying And Fixing Steel Pressed Single Panelled Door Of Size 120*205Cm With Steel Frames Using Superior Quality Gi Sections Made Of Tata Steel , Od398630/2025-2026 Providing And Fixing Roller Blinds Curtains Using Good Quality Materials, Fitted To The Wall With Necessary Fittings. All Complete As Per Direction Of Engineer In-Charge , Od398632/2025-2026 Providing And Fixing Of Acrylic Name Board With Printed Acrylic Board .All Work As Per The Direction Of Engineer In Charge , Od398631/2025-2026 Supply And Fixing Of Name Board Of Size 3.60*0.60M Made Of Acp Panels Supported Over Gi Frame Work , Furnishing Work , Od398627/2025-2026 Providing And Fixing Staff Table Of Size 2.00X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete.. , Od398625/2025-2026 Providing And Fixing Staff Table Of Size 1.80X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete. , Od398626/2025-2026 Providing And Supplying Staff Revolving Chair , Od398629/2025-2026 Supplying High Back Executive Chair Nylon Base Multi-Function Mechanism, With Cushion And Leather Finish, Including Transporting Charges And All Other Loading And Handling Charges. , Od398628/2025-2026 Supplying Of Public / Waiting Seating: Three Seater. ( 35 Kg - Gw ) Gauge : 14 &Rdquo;, Dimension: 173Cm * 64Cm * 89Cm. Seat Dimension : 43Cm * 51Cm * 49Cm. Seat &Amp; Back: 1.5Mm Perforated Powder Coated. Beam: 2.0Mm Mild Steel Powder Coated , Od398624/2025-2026 Supply Of Godrej Steel Shelf Of Size 1.00 X 0.50 X2.10M, 16 Gauge , Made Of Good Quality Sheet Applying Suitable Paints All Complete As Per The Direction Of Engineer-In Charge , Plumbing And Sanitary Fittings , 17.3.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.7.8 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 , 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend. , 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee , 50.18.9.13.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 12 Kgf/ Cm2- External Work- Exposed On Wall Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mml Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.17.1 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall , 50.18.9.20.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 63 Mm Dia Bendl , 50.18.9.20.5 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement - 63X63x63 Mm Dia Tee , 18.54.4 Providing And Fixing Ptmt Bib Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 90 Mm Long, Weighing Not Less Than 93 Gms , Electrical Works , 90.1.1.1 Supply And Laying Medium Gauge Pvc Conduit Of The Following Sizes Conforming To Is 9537/1983 Part Iii In Roof Slab, Jointing The Pipes With Pvc Solvent Cement, Tying & Fixing The Conduit Firmly With The Re-Inforcement Etc. As Required.20 Mm , 90.2.2.1 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 1.10.2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mmfrls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B , 90.2.2.3 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point Without Ceiling Rose - Short Point , 90.2.2.4 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.2.5 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Call Bell Point With 6 A Bell Push At One End And 6 A, 3 Plate Ceiling Rose At Other End - Short Point , 90.2.2.6 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points , 90.2.2.7 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Independent Plug - Short Points , 90.3.18.2 Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.32 Mm Dia With Hg Company Fabricated Clamps , 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , 90.5.1.3 Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650/1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.10.3.15 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )32A Dp Switch With Indicator) , 90.10.3.14 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A Sp Switch With Indicator , 90.10.3.32 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3 Pin Plug Top With Indicator , 90.10.3.33 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3Pin Shuttered Socket , 90.15.4.2 Supply Conveyance, Installation, Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.16.1.3 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.1.1 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.5.3 Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 2.3.1 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 6 Way, Double Door , 2.3.4 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door , 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , 2.10.3 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole , 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Commissioning Etc. As Required. 40 Amps Amps , 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And , 1.17.2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 1.5 Sq. Mm , 1.17.4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 1.5 Sq. Mm , 1.17.11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 2.5 Sq. Mm , 1.17.13 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 2.5 Sq. Mm , 1.17.20 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 4 Sq. Mm , 1.17.29 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 6 Sq. Mm , 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 annual periodical maintenance Switch , 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 annual periodical maintenance Socket Outlet , 1.26 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.56 Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5/6 A Modular Socket Outlets And 2 Nos. 5/6 A Modular Switches, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , 1.58 Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Od398610/2025-2026 Supply ,Installation Of 32 A Kit Cat Fuse Unit Made By Porcelain/ Ceramic , Od398618/2025-2026 Providing And Fixing Of Service Pipe (32 Mm) , Od398612/2025-2026 Supply And Fixing 200Mm Plastic Shade On Existing Batten/Angle/Pendant/Bracket Fittings As Required , Od398615/2025-2026 Supply And Fixing 9 W Led Bulb On Existing Lamp Holder B22 , Od398613/2025-2026 Supply And Providing Suitable Iron Hook Grouted On The Ceiling For Hooking The Ceiling Fan , Od398622/2025-2026 Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss. -200 Mm, Single Phase Light Duty Exhaust Fan In Plastic Frame ( Light Duty Exhaust Fan) , Od398616/2025-2026 Fabrication, Supply And Installation Of Wall Mounting Powder Coated Open Type Gi Meter Box Of Following Size Suitable For Fixing Single Phase Energy Meter, Kit Cat Fuse, Neutral Link Etc. Hinged Door Construction, Knock Out For Cable Entry Etc. As Required , 90.6.6.2 Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.2.50 Sq Mm , Od398614/2025-2026 Supply Installation Testing And Commissioning Of Single Phase Dol Starters For 0.25 To 3 Hp Motor , Od398617/2025-2026 Supply Installation Testing And Commissioning Of Water Purifier Wit The Following Specifications (12 L Ro + Uv + Tds + Controller) , Od398619/2025-2026 Supply Installation Testing And Commissioning Of Iso / Bis Certified Igbt Technology Based 2.5Kv Online Ups/Inverter With Minimum 3 Years On-Site Waaranty And Having The Following Minimum Specifications. 1. Output:230V+1% 50Hz Sine Wave Single Phase. 2. Input: 170V To 270V Hz Ac 3. Rating: 2.5Kva, 4. Backup Time: Minimum 2 Hrs, On Full Load, 5. Efficiency: 90% Or Higher. 6. Battery Bank: 150Vah/Above(2Nos) Or Higher Tubular Battery With Minimum 3 Years Warranty With Suitable Battery Rack. 7. Protection: Over Load, Short Circuit, Battery Reverse Polarity, Input Voltage Below Or Above The Specified Range Over Discharge Or Charge Of Battery, Accepted Model: Hykon Or Equivalent Brand With Better Specification. , Od398620/2025-2026 Supply, Conveyance, Installation And Testing Of 80Cm(32 Inch) Hd Ready Led Tv Of The Following Sizesusing Standard Accessories Including And Providing Wall Mounting Stands. Screen Resolution 1366X768- Hd And 2 Hdmi &Amp; 1 Usb Ports, Working On 230V/240V Single Phase A/C As Required , Od398611/2025-2026 Supply And Installation Of Set Top Box , Od398623/2025-2026 Earthing With G.I. Earth Pipe 2.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But With Charcoal/ Coke And Salt) As Required , Od398621/2025-2026 Supply &Amp; Installation Of 1200Mm, 20W Led Tube And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire . , Network Wiring And Installation , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 1.27.1 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.53.1 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Od398643/2025-2026 Providing And Fixing Of 16-Port Gigabit Unmanaged Switch.( D-Link Dgs-1016A Or Equivalent ) , Od398639/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398644/2025-2026 Supply Installation Testing And Commissioning Of Following Sizes Of Wall Mount Network Rack. 4U 350D( But Without Server, Switches Cooling Fans Etc.) , Od398636/2025-2026 Supply Installation Testing And Commissioning Of Cat6 Utp 24-Port Network Panel Desktop 19-Inch Rack Integration Server Mounting Shielded.24 Port Laded Patch Panel (D-Link Or Equivalent) As Required. , Od398634/2025-2026 Supply Installation Testing And Commissioning Of Wireless Ac1200, Dual-Band And Ceiling Mount Gigabit Access Point (Tp-Link Eap225 Ac1200 Wireless Mu-Mimo Gigabit Indoor/Outdoor Access Point/ Equivalent) , Od398637/2025-2026 Supply And Stackingg Of Cat-6 Patch Cord -2M , Od398640/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable-1Mtr , Od398642/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable- 0.5 Mtr , Od398641/2025-2026 Supply, Conveyance, Installation And Testing Of Cooling Fan For Incubator, Fan For Computer Server 120 * 120 * 38Mm, 4.7 Inch Black , Od398638/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398635/2025-2026 Supply Conveyance And Installation Of Poe Injector. (Tenda Te-Poe30g-At Gigabit Poe Injector Or Equivalent) N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
43.
Educational and Research Institute #11191269 AOC
Tender For Supply And Installation Of Furniture At Library And Computer Building. , Furniture , Library Chair -01 -Seat Size: 50.0Cm. (W) X 48.0 Cm. (D) -Back Size: 53.0 Cm. (W) X 39.0Cm. (H) -Injection Moulded Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ & Hardness 16 Kgf. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -M.S. Powder Coated Frames (Dft 50 Microns) For 4 Leg Chairs -M. S Pipe Dia 25Mm (Vendor To Submit Powder Coating Laboratory Test Certificate) -Glass Filled Polypropylene Armrest With The Tubular Frame. -Vendor Should Submit Detail Shop Drawings With All Dimensions. , Office Chair Seat Size- 53.5 Cm. (W) X 51.0 Cm. (D), Of 1.5 Cm Thickness Plywood Preferably Hot-Pressed, Furnished With Fabric Covers -Mesh Back Size- 51.0 Cm. (W) X 70.0 Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Glass Filled Nylon Armrest With The Tubular Frame Of 6 Cm Hight(Adjustable) -Center Tilt Synchro Mechanism With Seat Slide & Multi Lock, Revolving 360° -Head Rest Sub-Assembly With Hight Adjustment Up To 4 Cm. -Pneumatic Height Adjustment Of 9.5Cm, Pedestal Assembly Of Polished Aluminium With Twin Wheel Injection Moulded Soft Castors Of Nylon With Pu Lining, Having Up To 6 Cm Wheel Diameter. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation Chair Seat Size- 53.5 Cm. (W) X 51.0 Cm. (D), Of Thickness 1.5 Cm Plywood Preferably Hot-Pressed, Furnished With Fabric Covers. -Mesh Back Size- 51.0 Cm. (W) X 70.0 Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Glass Filled Nylon Armrest With The Tubular Frame Of 6 Cm Hight(Adjustable) -Center Tilt Synchro Mechanism With Seat Slide & Multi Lock, Revolving 360° Anti-Shock Mechanism. -Pneumatic Height Adjustment Of 9.5Cm, Pedestal Assembly Of Polished Aluminium With Twin Wheel Injection Moulded Soft Castors Of Nylon With Pu Lining, Having 6 Cm Wheel Diameter. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Conference Chair Seat Size: 49.0 Cm. (W) X 51.4 Cm. (D) Of Thickness 1.2 Cm Plywood Preferably Hot-Pressed, Furnished With Synthetic Leather Over Moulded High Resilience Polyurethane Foam. -Mid Back Size: 51.6 Cm. (W) X 65.7 Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 55 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Chrome Plated Up-Down Adjustment Armrest Of 8 Steps. -360° Revolving Type Front Pivot Synchro Mechanism, 4-Position Locking With Anti-Shock Feature, Tilting Ratio Of 1:2, Single Point Control. -Back Height Adjustability, Adjusted In 5 Positions. -Pneumatic Height Adjustment Of 10Cm, Pedestal Assembly (Pedestal- 65 Cm, Pitch-Center Dia. 75Cm) Of Polished Aluminium With Twin Wheel Injection Moulded Castors. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Study Chair With Writing Pad Seat Size : 50.0Cm. (W) X 48.0 Cm. (D) Furnished With Fabric Covers And Moulded Polyurethane Foam -Back Size : 53.0 Cm. (W) X 39.0Cm. (H) -Seat With High Resilience Polyurethane Seat Foam With Density 45 Kg/M³ And Hardness 16 Kgf (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -M.S. Powder Coated Frames Dia 25Mm (Dft 50 Microns) For 4 Leg Chairs With Glass Filled Polypropylene Shoe (Vendor To Submit Powder Coating Laboratory Test Certificate) -The Full Desklet Made Of 1.3 Cm. Thick, Compact Laminate Board. Having Front And Back Adjustment Of 4 Cm -Outer Dimension 59.5±0.1Cm. (W) X 29.0±0.1Cm -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Conference Table With Seating Capacity Of 18Seats 2 Str Main - 1350 X 600 X 740 - 2 Nos. -2 Str Shared - 1350 X 600 X 740 - 2 Nos. -2350W - 2350 X 850 X 740 - 2 Nos. -Work Surface Made Of 25Mm Thick Pre-Laminated Twin Board With A High-Quality Wood Matching 2 Mm Thick Pvc Lipping; Plastic Access Flap Is Provided For Easy Access To Wires And Cables -Under Structure Consists Of 18Mm Thick Pre-Laminated Twin Board Wood Matching 2 Mm Thick Pvc Lipping -Modesty Panel-Made Of 18Mm Thick Pre-Laminated Twin Board Of Wood Matching 2 Mm Thick Pvc Lipping -Powder Coated Accent Metal Strip Provided Below Work Surface Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent Steel, Epoxy Polyester Powder Coated (Dft 40-60 Microns). (Vendor To Submit Powder Coating Laboratory Test Certificate) -Wire Management- An Array Of Panels Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent, Epoxy Polyester Powder Coated (Dft 40-60 Microns) Is Used For Flow Of Wires And Cables. Provision To Mount 6 Module Electric Switch Plate Is Provided Below Worktop. Cut-Out On Top With Two-Piece Injection Moulded Plastic Part Polymer Component Is Fitted To Pull Out Audio, Video Cables Onto Worktop And Connect Devices Charger To Power Socket Below Worktop. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Conference Table With Seating Capacity Of 30 Seats 2 Str Main - 1350 X 600 X 740 - 2 Nos. -2 Str Shared - 1350 X 600 X 740 - 8 Nos. - 2Str -2350 X 850 X 740 - 2 Nos. -Work Surface Made Of 25Mm Thick Pre-Laminated Twin Board With Wood Matching 2 Mm Thick Pvc Lipping; Plastic Access Flap Is Provided For Easy Access To Wires And Cables -Under Structure Consists Of 18Mm Thick Pre-Laminated Twin Board Of High-Quality Wood Matching 2 Mm Thick Pvc Lipping -Modesty Panel-Made Of 18Mm Thick Pre-Laminated Twin Board Of High-Quality Wood Matching 2 Mm Thick Pvc Lipping -Powder Coated Accent Metal Strip Provided Below Work Surface Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent Steel, Epoxy Polyester Powder Coated (Dft 40-60 Microns). (Vendor To Submit Powder Coating Laboratory Test Certificate) -Wire Management- An Array Of Panels Made Of 0.8Mm Crca Or Equivalent Grade Steel Or Equivalent, Epoxy Polyester Powder Coated (Dft 40-60 Microns) Is Used For Flow Of Wires And Cables. Provision To Mount 6 Module Electric Switch Plate Is Provided Below Worktop. Cut-Out On Top With Two-Piece Injection Moulded Plastic Part Polymer Component Is Fitted To Pull Out Audio, Video Cables Onto Worktop And Connect Devices Charger To Power Socket Below Worktop. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Two-Seater Sofa Seat Is Made Up Of Pu Foam In Density 28 Kg/Cu.Mtr With An Additional Top Layer Of Super Soft Pu Foam Furnished With Fabric Or Leatherette.(Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Back Is Made Up Of Pu Foam In Density 28 Kg/Cu. Mtr With Two Additional Top Layers Of Super Soft Foam Furnished With Fabric Or Leatherette. -Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Leg Assembly Is A Welded Assembly Made In Stainless Steel Tube & Plate With Plastic Endcap Of 146 X 90 X 85.5 Cm With Seat Height Of 45 Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Three-Seater Sofa Seat Is Made Up Of Pu Foam In Density 28 Kg/Cu.Mtr With An Additional Top Layer Of Super Soft Pu Foam Furnished With Fabric Or Leatherette. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Back Is Made Up Of Pu Foam In Density 28 Kg/Cu. Mtr With Two Additional Top Layer Of Super Soft Foam Furnished With Fabric Or Leatherette. -Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Stainless Steel (Grade Ss 202) O Equivalent Grade Tube Welded Leg Assembly With Plastic Endcap Of 206 X 90 X 85 Cm Seat Height 45Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions. , One Seater Sofa Seat Is Made Up Of Pu Foam In Density 28 Kg/Cu.Mtr With An Additional Top Layer Of Super Soft Pu Foam Furnished With Fabric Or Leatherette. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Back Is Made Up Of Pu Foam In Density 28 Kg/Cu. Mtr With Two Additional Top Layers Of Super Soft Foam Furnished With Fabric Or Leatherette. -Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Stainless Steel (Grade Ss 202) Or Equivalent Grade Tube Welded Leg Assembly With Plastic Endcap Of 86 X 90 X 85 Cm Seat Height 45Cm. -Vendor Should Submit Detail Shop Drawing With All Dimensions. Under Structure Is Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood With Moisture Resistance & Termite Proof. -6 Nos. Per Seat & 3.8Mm Dia Zigzag Spring Assembly Is Mounted Over Under Structure For Cushioning Purpose. -Stainless Steel (Grade Ss 202) O Equivalent Grade Tube Welded Leg Assembly With Plastic Endcap Of 86 X 90 X 85 Cm Seat Height 45Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Mobile Compactor Storage Unit-01 3 Bay Drive Type Compactors With 3 Bay Sd - 1 No, 3 Bay Td - 1 No, 3 Bay Sl - 1 No. 3 -Size Of Compactor 2361H Mm X 915 W Mm X 457D Mm, 3 Bay Channel 2400 Mm - 3 No, 3 Bay Channel 800 Mm - 3 No. -Main Body: Rigid Knock Down Construction Made Of 0.8 Mm Thick. Crca Or Equivalent Grade Steel Having 5 Loading Levels Formed By 4 Adjustable Shelves For 1980 Mm Height Body And 6 Loading Levels With 5 Adjustable Shelves For 2361Mm Height Body. -Main Body Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction: Rigid Knock Down Construction Made Of 0.8 Thick Crca Or Equivalent Grade Steel. Each Body Block Consists Of 1 Main Unit & Then Add-On Units. -Front Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose. -Back Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose. -Back Panel Made Of 0.6 Thick Crca Or Equivalent Grade Steel Fixed Together Using Machine Screws To Prevent Access To Inside Files From The Outside. -Door Frame Made Of 0.8 Thick Crca Or Equivalent Grade Steel Of 2 Vertical Door Stiffeners Providing Rigidity To The Entire Body. -Shelf Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction 12-Bend Panel Made Of 0.7 Thick Crca Or Equivalent Grade Steel Having Max Load Bearing Capacity Is 100 Kg Uniformly Distributed Per Shelf, Height Of 351Mm Between Two Shelves. The Last Loading Level For Shelf Is 1721Mm From Ground Level For 1980H Body And 2107Mm From Ground For 2361H Body. Shelves Are Mounted On Support Brackets & Shelf Level Can Be Adjusted At Approx. 25.4 Pitches. There Are 4 Adjustable Shelves Per Body For 1980H And 5 Adjustable Shelves Per Body For 2361H, Giving 5 And 6 Loading Levels For 1980H And 2361H Body Respectively. -Storage Capacity Made Of 0.8Thick Crca Or Equivalent Grade Steel Having Hinged Door Have Recessed Die Cast Handle Cum Lock With 3 Way Locking Through A Lever & Shooting Bolt And Can Hold Up To 10 Nos. Of Box Files -Under Structure Construction Welded Frame Suitably Fabricated To Bear The Loads Based On Configuration Consists Of The Main Channel, Body-Fixing Channel, U-Channel, And Z-Channel Made Of Hr Sheet 3 Mm Thick. -Under Structure Construction Finish Epoxy Polyester Powder Coat Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Movements Of The System Is Drive Type Configuration Achieved By Rotating A Pu Hand Wheel Connected To The Rollers Through A ‘Sprocket-Chain Arrangement Mounted On The Side Of The Body Covered By A 1 Mm Thick Crca Or Equivalent Grade Steel Sheet Drive Unit Cover With Dimensions 1202Mm X 398Mm X 87Mm -Rail Channels- A ‘C Section 3 Mm Thick Hr Sheet On Which Rail Ms Bright Bar Of Sq 25.4Mm Is Firmly Fixed From Bottom Using Counter Sunk Screws. The Rail Channels Are Of 3 Lengths I.E., 800Mm, 1600Mm And 2400Mm. Label Holder Is An Aluminium Extrusion Of Length 453Mm For Ld/Sd And 910Mm For Td, Fitted On To Front Cover Of Body. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Mobile Compactor Storage Unit -02 3 Bay Drive Type Compactors With 3 Bay Sd - 1 No, 3 Bay Td - 2 No, 3 Bay Sl - 1 No. -Size Of Compactor 2361H Mm X 915 W Mm X 457D Mm, 3 Bay Channel 2400 Mm - 1 No, 3 Bay Channel 800 Mm - 1 No. -Main Body : Rigid Knock Down Construction Made Of 0.8 Thick. Crca Or Equivalent Grade Steel Having 5 Loading Levels Formed By 4 Adjustable Shelves For 1980 Mm Height Body And 6 Loading Levels With 5 Adjustable Shelves For 2361Mm Height Body. -Main Body Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction: Rigid Knock Down Construction Made Of 0.8 Thick Crca Or Equivalent Grade Steel. Each Body Block Consists Of 1 Main Unit & Then Add-On Units. -Front Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose -Back Cover Made Of 0.8 Thick Crca Or Equivalent Grade Steel Which The Handles Drive Unit Having Holes On The Front Surface For Ventilation Purpose. -Back Panel Made Of 0.6 Thick Crca Or Equivalent Grade Steel Fixed Together Using Machine Screws To Prevent Access To Inside Files From The Outside -Door Frame Made Of 0.8 Thick Crca Or Equivalent Grade Steel Of 2 Vertical Door Stiffeners Providing Rigidity To The Entire Body -Shelf Finish: Antirust Surface Treatment Coated With Epoxy Polyester Powder Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Shelf Construction 12-Bend Panel Made Of 0.7 Thick Crca Or Equivalent Grade Steel Having Max Load Bearing Capacity Is 100 Kg Uniformly Distributed Per Shelf, Height Of 351Mm Between Two Shelves. The Last Loading Level For Shelf Is 1721Mm From Ground Level For 1980H Body And 2107Mm From Ground For 2361H Body. Shelves Are Mounted On Support Brackets & Shelf Level Can Be Adjusted At Approx. 25.4 Pitches. There Are 4 Adjustable Shelves Per Body For 1980H And 5 Adjustable Shelves Per Body For 2361H, Giving 5 And 6 Loading Levels For 1980H And 2361H Body Respectively. -Storage Capacity Made Of 0.8Thick Crca Or Equivalent Grade Steel Having Hinged Door Have Recessed Die Cast Handle Cum Lock With 3 Way Locking Through A Lever & Shooting Bolt And Can Hold Up To 10 Nos. Of Box Files -Under Structure Construction Welded Frame Suitably Fabricated To Bear The Loads Based On Configuration Consists Of The Main Channel, Body-Fixing Channel, U-Channel, And Z-Channel Made Of Hr Sheet 3 Mm Thick. -Under Structure Construction Finish Epoxy Polyester Powder Coat Of Approved Colour & Shade With A Dry Film Thickness Of Minimum 40 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Movements Of The System Is Drive Type Configuration Achieved By Rotating A Pu Hand Wheel Connected To The Rollers Through A ‘Sprocket-Chain Arrangement Mounted On The Side Of The Body Covered By A 1 Mm Thick Crca Or Equivalent Grade Steel Sheet Drive Unit Cover With Dimensions 1202Mm X 398Mm X 87Mm -Rail Channels- A ‘C Section 3 Mm Thick Hr Sheet On Which Rail Ms Bright Bar Of Sq 25.4Mm Is Firmly Fixed From Bottom Using Counter Sunk Screws. The Rail Channels Are Of 3 Lengths I.E., 800Mm, 1600Mm And 2400Mm. Label Holder Is An Aluminium Extrusion Of Length 453Mm For Ld/Sd And 910Mm For Td, Fitted On To Front Cover Of Body. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Magazine Stand Overall Dimensions 900Mm(W)X450Mm(D)X1830Mm(H). -Steel Periodical Display Rack Providing, Placing And Supplying Of Display Rack. -Rigid Knockdown Construction, Panels Shall Be Made From Crca Or Equivalent Grade Steel 0.6 Mm Thick -Front Frame Shall Be Made From Crca Or Equivalent Grade Steel 0.8 Mm Thick. Crca Or Equivalent Grade Steel D Grade. -There Shall Be 5 Level Racks, Suitable For Full Cape Size Magazines, Periodicals, Aesthetically Appealing Metal Tray At An Angle For Easy Viewing. -Receding Facility To Access The Storage Behind. -Uniformly Distributed Load Capacity Per Each Shelf Is 40 Kg. -Shall Be Epoxy Polyester Powder Coated To The Thickness Of 50 Microns. (Vendor To Submit Powder Coating Laboratory Test Certificate) Vendor Should Submit Detail Shop Drawing With All Dimensions. , Storage Cabinet 1 Body Made From 18Mm Plb With All The Edges Sealed With 0.8 Mm Thick Pvc Edge Band. The Shelves Is Made From 18 Mm White Plt And Edges Are Sealed With 0.8 Mm Edge Band. The Back Panel Is 9Mm White Plt Assembled With Suitable Fittings. The Bottom Shelf Is Fixed And Other Shelves Have One Step Adjustment For Optimizing The Space. -Doors Made From 18 Mm Plb With 2 Mm Edge Band On All Edges Ad A Flush Plastic Handle Is Fitted Vertically At The Centre Of The Door Having Suitable Hinges And Hdu Is Fitted With Height Adjustment And Has A Three-Point Lock. -All The Storages Are Fitted With A 6 Mm Leveller At Bottom For Levelling As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Storage Cabinet -02 Body Made From 18Mm Plb With All The Edges Sealed With 0.8 Mm Thick Pvc Edge Band. The Shelves Is Made From 18 Mm White Plt And Edges Are Sealed With 0.8 Mm Edge Band. The Back Panel Is 9Mm White Plt Assembled With Suitable Fittings. The Bottom Shelf Is Fixed And Other Shelves Have One Step Adjustment For Optimizing The Space. -Doors Made From 18 Mm Plb With 2 Mm Edge Band On All Edges Ad A Flush Plastic Handle Is Fitted Vertically At The Centre Of The Door Having Suitable Hinges And Hdu Is Fitted With Height Adjustment And Has A Three-Point Lock. -All The Storages Are Fitted With A 6 Mm Leveller At Bottom For Levelling As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Library Table 1 1650 X 600 Desk Based Modular Workstation With System Ht-750 Mm. -Partial Screens: Fabric T- Mould, 19Mm Thick Screen Of 450Mm Ht., Mounted On Studs. -Legs: Providing Metal Powder Coated Cube Leg Vertical (40X40Mm)& Rigid Support (50X30Mm). Legs Are For Standard Workstation Height Of 750Mm. All Legs Have Levelling Screws For Adjustment In Case Of Uneven Floor. -Understructure Comprising Of Metal Powder Coated Cross, Made Up Of Metal Powder Coated Finish -Wire Management: Electric Switch Plate Of 8+3 Module For Power And Data Points. -Worksurface - 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lipping Edge Banding Of Size 1650 Mm W X 600 Mm D. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Library Table -2 2400 X 1200 Providing And Placing Modular Workstation Desk Based Modular Workstation With System Ht - 750 Mm. -Legs: Providing Metal Powder Coated Cube Leg. Legs Are For Standard Workstation Height Of 750Mm. All Legs Have Levelling Screws For Adjustment In Case Of Uneven Floor. -Understructure Comprising Of Metal Powder Coated Cross, Made Up Of Metal Powder Coated Finish -Wire Management: Electric Switch Plate Of 8+3 Module For Power And Data Points. -Worksurface - 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lipping Edge Banding Of Size 2400 Mm W X 1200 Mm D. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Reception Table Work Surface Made Of 25Mm Thick Pre-Laminated Twin Board Of High Quality Wood And Approved Shade Confirming To Edge Banded With Matching 2 Mm Thick Pvc Lipping. -Wire Managementu-Access Flap Along With A Grommet Is Provided On Work Surface For Wire Management. Power Box Made With 0.8 Mm Thick Crca Or Equivalent Grade Steel, With Electric Switch Plate Of 8+3 Module Which Is Fixed With Worktop Along The Width Ataccess Flap Position. Wire Riser Made Of 0.8Mm Crca Or Equivalent Grade Steel Is Provided For Proper Wire Management. -Modesty Panel & Side Skirting - Made Of 25Mm Thick Pre-Laminated Twin Board Of High Quality Wood And Approved Shade, Edge Banded With Matching 2 Mm Thick Pvc Lipping. -Under Structure And Top Shelf - Made Of 18 Mm Thick Pre-Laminated Twin Board Of High-Quality Wood And Approved Shade, Edge Banded With Matching 2 Mm Thick Pvc Lipping - Hinge Door + Drawer Unit - Made Of 18Mm Thick Pre-Laminated Twin Board Of High Quality Wood And Approved Shade, Edge Banded With Matching 2 Mm Thick Pvc Lipping. Drawer Bottom Is Made Of 5.5Thick Mdf Whiteboard Handle Is Provided For Ease Of Opening. Hdu And Drawer Are Provided With Cam Lock For Security. -Organizer Plate Made Of 1.2Mm Crca Or Equivalent Grade Steel Is Provided For Magnetic Sticky Notes. -Bag Hanger Hook Made Of 1.2Mm Crca Or Equivalent Grade Steel Is Provided For Bag Hanging 2400 X 1770 X 870 Mm , Side Table Providing, Supplying And Placing Of Side Table. -Side Table Glass Is 10 Mm Thick Black Tinted Toughened Glass Uv Glued With Bushes Made In Ss 202 Grade Or Equivalent For Facing With Under Structure. -Under Structure Is A Welded Assembly Made In Ss202 Or Equivalent Grade -Width Of Table= 60.0 Cm, Depth=60.0 Cm, Height=34.9 Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions , Central Table Providing, Supplying And Placing Of Coffee Table. -Center Table Glass Is 10 Mm Thick Black Tinted Toughened Glass Uv Glued With Bushes Made In Ss 202 Or Equivalent Grade For Facing With Under Structure. -Under Structure Is A Welded Assembly Made In Ss202 Grade Or Equivalent -Width Of Table= 112.0 Cm, Depth=60.0 Cm, Height=34.9 Cm. Vendor Should Submit Detail Shop Drawing With All Dimensions , Round Table Circular 900Mm Providing And Placing Meeting Tables With Worktop Height - 750 Mm. Cube Legs Vertical (40X40Mm).Rigid Support-(50X30Mm) Are Available For Work Top Level 750 Mm From Base. -Worktop Is 25Mm Thick Prelaminated Particle Board With Pvc Lipping As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Table A- 750X1500 Providing And Placing Desk Based Modular Workstation With System Height - 750 Mm. -Legs Providing Metal Powder Coated Cube Leg Vertical (40X40Mm) Rigid Support (50X30Mm). Legs Are For Standard Workstation Height Of 750Mm. All Legs Have Levelling Screws For Adjustment In Case Of Uneven Floor. -Under Structure Made Up Of Metal Powder Coated Finish And The Entire Assembly Are Fixed To The Worktop. -Wire Management Will Be Provided With Electric Switch Plate Of 8+3 Module, Considered For Power And Data Points. . (Vendor To Submit Powder Coating Laboratory Test Certificate) -Metal Modesty And Wooden Modesty Are Mounted On The Worktop Perforated With The Help Of The Modesty Mounting Brackets At 400 Mm From Ground. -Worksurface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lipping Edge Banding Of Size 1500X 750 Mm For Main Table As Per Order. Vendor Should Submit Detail Shop Drawing With All Dimensions , Meeting Table Eight-Seater 2350 X 1150 Mm Work Top Made Of 25Mm Thick Pre-Laminated Twin Board Of High-Quality Wood; Edge Banded With Matching 2 Mm Thick Pvc Lipping. Access Panels Provided With Soft Closing Hinges. -Under-Structure Consists Of Mixture Of 25Mm And 18Mm Pre-Laminated Twin Board Of High-Quality Wood; Edge Banded With Matching 2 Mm Thick Pvc Lipping. Access Panels Provided With Soft Closing Hinges. Aluminium Alloy 63400 Or Equivalent - Wp Profile Is Added At Bottom Edges For Improving The Aesthetics. -Wire Management Will Be Provided With Electric Switch Plate Of 8+3 Module, Considered For Power And Data Points. Beside Each Cut-Out, An Additional Cut-Out With Plate Is Provided For Mounting Audio-Visual Cables (E.G. Hdmi, Vga-A, Etc.) Vendor Should Submit Detail Shop Drawing With All Dimensions , Table B Supplying And Placing In Position Main Table, Of Dimension 1800X2100X750 Mm. -Primary Work Surface Made Of 25Mm Thick Mdf One Side Pre-Laminate Board With 0.4Mm Pvc. -Secondary Work Surface Made Of 25Mm Thick Mdf One Side Pre-Laminate Board With 0.4Mm Pvc. -Under Structure Made Of 25Mm Thick Pre-Laminated Twin Board Of High Quality Wood, Edge Banded With Matching 2 Mm Thick Pvc Lipping. Integrated Pedestal Made Of 25Mm Thick Pre-Laminated Twin Board Of High-Quality Wood, Edge Banded With Matching 2 Mm Thick Pvc Lipping.  Drawer Fronts Made Of 25Mm Thick Mdf One Side Pre-Laminate Board With 0.4Mm Pvc Membrane Pressed On To Top. Pedestal Construction Is Box-Box-File Type Which Uses Powder Coated 400 Mm Long Metal Panel Drawer Slides. Drawer Extension Is 325 Mm. Drawers Have A Soft Closing & Anti Slam Mechanism. Handles Are Provided For Ease Of Opening. Pedestals Are Provided With Lock For Security. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Modular, Space-Optimizing Desk With Bench N (Three-Seater Curved) Providing, Supplying And Placing Of Desk Cum Bench N Seater Product Which Provides An Elegant, Modular Solution With 360-Degree Swivel Seat For Easy Entry/Exit And Height-Adjustable -Legs Are Made Of Ms Erw Or Equivalent Tube Section Of Size 75X25X2 Mm Thick Oval Tube With 5 Mm Thick Hr Bracket Sand 2Mm Thick Crca Or Equivalent Grade Steel Brackets On To The Tubes. -Assembly Is Powder Coated With Epoxy Polyester. Leg Height Varies From 705 To 1005 In Pitch Of 50 As Per Layout. Sturdy Anchoring By Anchor Bolts On To Base Of 8Mm Thick Plate For Proper Resting Of Leg. Shoe Made Of Nylon Are Provided At The Bottom For Covering The Base Plate. -Two Side Clads Made Of E18 Mm Thick Plate With 0.8Mm Thick Pvc Lapping And On The Outside Covered With Welded Metal Structure Made Of 2 Mm Thick Crca Or Equivalent Grade Steel Powder Coated With Epoxy Polyester. -Worktop Are Made Of 25 Mm Thick Pre-Laminated Board Of High-Quality Wood; All The Edge Of Work Surface Should Provide With Machine Pressed 2 Mm Thick Pvc Edge Band Glued With Hot Melt Glue. -Seat Has Self-Closing Mechanism. Seat Under Structure Is Made From Combination Of Welded Fabricated Structure Of 5Mm Thick Hr And 8Mm Thick Ply With Moulded Pu Foam Of Density 55 Kg/Cu.Mtr. With Stitched Fabric Made Of Leatherette Or Foam Back Fabric. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Seat Back Is Made From Combination Of 8Mm Thick Ply With Moulded Foam On Top Which In Turn Is Covered With Stitched Upholstery Made Leatherite As Per Or Foam Back Fabric. (Vendor To Submit Foam Density And Hardness Laboratory Test Certificate) -Seat Support Frame Is Made From Combination Of Ms Erw Or Equivalent Grade Tube Section Of Size 80X40X2.5 Mm Thick Rectangular Tube And Ms Erw Tube Section Of Size 48X19.1X2 Mm Thick Oval Tube Welded Together. Assembly Is Powder Coated With Epoxy Polyester. -Modesty Is Made Of 25Mm Thick Pre-Laminated Twin Board Of High-Quality Wood, All The Edge Of Modesty Are Provided With Machine Pressed 2 Mm Thick Pvc Edge Band Glue With Hot Melt Glue. Vendor Should Submit Detail Shop Drawing With All Dimensions . , Table C 1650X600X770Mm Providing, Supplying And Placing Of Conference Table With Product Size 1650 X 600 X 770Mm -Worktop Should Be Made Of 25Mm Thick High-Quality Wood, Edges Shall Be Provided With Machine Pressed 2 Mm Thick Pvc Lipping Glued With Hot Melt Eva Glue. -All Tables Are Provided With Heavy Duty Table Connector Made With Metal Integrated Engineering Plastic. -Modesty Should Be Made Of 15Mm High Quality Wood, Edges Shall Be Provided With Machine Pressed 2 Mm Thick Pvc Lipping Glued With Hot Melt Eva Glue. -Recta Table Modesty Is Provided With A Latch Made Of 2Mm Thick Crca Or Equivalent Grade Steel And Is Powder Coated With Min 45-Micron Thickness Of Epoxy Polyester Coating. Latch Is Fixed With Knurled Bush Made Of 20Mm Dia Ms Rod In A Black Finish. Latch Can Be Used To Align Modesty If Two Or More Recta Tables Are Connected Side By Side. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Modesty Is Provided With Rubber Stopper Made Of Tpe Rubber To Reduce Banging While Folding Table. -Legs Should Be Made By Welding The Combination Of Ms Erw Or Equivalent Grade Round Tube Ø63.5 X 2Mm Thick, Flanges Made Crca Or Equivalent Grade Steel Sheet Of 1.6Mm Thick And 1.2Mm Thick Inside Plates Made Of Hr 5Mm Thick Sheet. Assembly Is Epoxy Polyester Powder Coated (Min 45 Micron). -Legs Are Provided With Casters Of Ø65 Mm Lockable Type For Ease Of Movement And Can Be Locked When Required At Any Position. Each Castor Is Also Provided With 2 Knurled Disk Of 50Mm Dia And 5 Mm Thick Made Of Ms Bar With Zn Black Finish For Levelling Adjustment Of 10Mm.. -Table Top Connected With Spring Loaded Mechanism With Pull Handle Made Of Ms Erw Ø16X1.2Mm Thick With An Insert Tube Of Ø12.7X1.6Mm Thick Tube. Coated With Epoxy Polyester Powder Coated (Min 45 Micron) To Operate Table Top. (Vendor To Submit Powder Coating Laboratory Test Certificate) -Table Top With Modesty Folds Upside At Offset Centre Pivot Provided On Support Bracket Which Is Aluminium Alloy Pressure Die Cast Part Coated With Epoxy Polyester Powder Coat (Min 45 Micron). Modesty Is Connected To Worktop With 90 Deg Rotating Hinge Made Of Engineering Plastic. -All Type Of Tables Are Provided With Power Box Which Has Two Universal Power Socket Of 2 Annual Periodical Maintenance Each, One Switch Of16 Annual Periodical Maintenance And 1 Fuse Of 4 Annual Periodical Maintenance With 1000Mm Cable With Male And Female Gst Connector. -All Tables Are Provided With Wire Channel And Wire Clip Made Of 1.2Mm Thick Spring Steel And Is Powder Coated With Min 45 Micron Thickness Of Epoxy Polyester Coating (Vendor To Submit Powder Coating Laboratory Test Certificate) Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation L Type Providing And Placing Desk Based Modular Workstation With System Height - 1200 Mm. -Partial Screens: Fabric T- Mould, 19Mm Thick Screen Of 450Mm Ht., Mounted On Studs. -Legs Providing Metal Powder Coated Cube Leg. Legs Are For Standard Workstation Height Of 750Mm. -Under Structure Made Up Of Metal Powder Coated Finish And The Entire Assembly Is Fixed To The Worktop. -Wire Management Will Be Provided With Electric Switch Plate Of 8+3 Module, Considered For Power And Data Points. -Worksurface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lapping Edge Banding Of Size 1500X1500X600 Mm. -Metal And Wooden Modesty Are Mounted On The Worktop With The Help Of The Modesty Mounting Brackets. -Nova Free Standing Pedestal With Flat Metal Front Of Size 390W X 435D X 646Ht, 1Dr = 1 Box + 1 File, Central Locking. Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation 2 -900X600Mm Providing And Placing High-Functionality, Modular Office Workstation System & Tile Based Modular Workstation, With Partition Thickness As 52.4 Mm Thick And Ht - 1200 Including Powder Coated Aluminium Trims. -Fin Are 22.5 Mm Thick Panel Which Are 18 Mm Thick Ply Boards Wrapped With Fabric At Intermediate Level. Top Block Finished In Fabric Finish. Bottom Block Is Finished In Metal Finish. -Wire Management: Wires Shall Be Taken Into The System Through Cable Ducts From The Junction Boxes And It Is Carried Up To The Panels Through Concealed Conduits Inside The Blocks. -Half Screen With Frame At Intermediate Position Between 2 People And At The End Above Worktop In Fabric Finish. -Metal Powder Coated Legs At The End And Shared Condition. System Shall Also Have 120 Mm High Powder Coated Standalone Panel Legs To Give The System An Elevated Look. All Partitions And Side Panels Have Levelling Screws For Adjustment In Case Of Uneven Floor -Work Surface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lapping Edge Banding Of Size 900 Mm W1 X600 Mm D As Per Order. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Workstation 3- 900X600Mm Providing And Placing High-Functionality, Modular Office Workstation System & Tile Based Modular Workstation, With Partition Thickness As 52.4 Mm Thick And Ht - 1050Mm Including Powder Coated Aluminium Trims. -Fin Are 22.5 Mm Thick Panel Which Are 18 Mm Thick Ply Boards Wrapped With Fabric At Intermediate Level. Bottom Block Is Finished In Metal Finish. -Wire Management: Wires Shall Be Taken Into The System Through Cable Ducts From The Junction Boxes And It Is Carried Up To The Panels Through Concealed Conduits Inside The Blocks. -Half Screen With Frame At Intermediate Position Between 2 People And At The End Above Worktop In Fabric Finish. -Metal Powder Coated Legs At The End And Shared Condition. System Shall Also Have 120 Mm High Powder Coated Standalone Panel Legs To Give The System An Elevated Look. All Partitions And Side Panels Have Levelling Screws For Adjustment In Case Of Uneven Floor -Work Surface Of 25 Mm Thick Prelaminated Particle Board With Flat Pvc Lapping Edge Banding Of Size 900 Mm W1 X600 Mm D As Per Order. -Vendor Should Submit Detail Shop Drawing With All Dimensions. , Main Table 1650 X 750, Eru- 1200W X 450D With Pedestal Modular Desk-Based System Of Height 750 Mm. -Cube Legs Are Fabricated By Argo Shield & Have A Square Section. Cube Legs(40X40Mm) And Rigid Support (50X30Mm) Are Available For Work Top Level 750 Mm From Base. -Wire Management: Single Power Box With Raiser For Manager Modules, Single Tables (8+3 Anchor Roma). Soft Closing Access Flap With Brush. -Metal Modesty Is Made From 0.8 Mm Thick Crca Or Equivalent Grade Steel. Metal Modesty Is Mounted On The Worktop With The Help Of The Modesty Mounting Brackets. -Worktop Of 25Mm Thick Prelaminated Particle Board With Pvc Lapping. -Nova Free Standing Pedestal With Flat Metal Front Of Size 390X435X646 Mm, 1Dr = 1 Box + 1 File, Central Locking. Vendor Should Submit Detail Shop Drawing With All Dimensions , Modular, Space-Optimizing Desk Legs Are Made Of Ms Erw Or Equivalent Grade Tube Section Of Size 75X25X2 Mm Thick Oval Tube With 5 Mm Thick Hr Brackets And 2Mm Thick Crca Or Equivalent Grade Steel Brackets Welded On To The Tubes. Assembly Is Powder Coated With Epoxy Polyester. Leg Height Varies From 705 To 1005 In Pitch Of 50 As Per Layout. Sturdy Anchoring By Anchor Bolts On To Base Of 8Mm Thick Plate For Proper Resting Of Leg. -Shoe Made Of Nylon Are Provided At The Bottom For Covering The Base Plate. -Two Side Clads Made Of 18 Mm Thick Plate With 0.8Mm Thick Pvc Lapping And On The Outside Covered With Welded Metal Structure Made Of 2 Mm Thick Crca Or Equivalent Grade Steel Powder Coated With Epoxy Polyester. -Worktop Are Made Of 25 Mm Thick Pre-Laminated Board Of El-P2 Grade And Approved Shade. All The Edge Of Work Surface Are Provided With Machine Pressed 2Mm Thick Pvc Edge Band Glued With Hot Melt Glue. -Modesty Is Made Of 25Mm Thick Pre-Laminated Twin Board Of E1-P2 Grade And Approved Shade. All The Edge Of Modesty Are Provided With Machine Pressed 2 Mm Thick Pvc Edge Band Glue With Hot Melt Glue As Per Order. -Vendor Should Submit Detail Shop Drawing With All Dimensions.
Contract Date: Jun 06, 2026 Contract Value : 6.64 Crore
Government Departments No of Bidders 8
Maharashtra View Result →
44.
Power #11177233 AOC
Tender For The Various Dcw Works And Improvement Works In O And M Perambalur Division; 1 Excavation of Pole Pits for poles upto 8.00m length by using JCB/Manual (1.25 X 0.6 X 1.5M) 2 Excavation of Pole Pits for pole above 8.00m length by using JCB/Manual (1.25x06x1.83M) 3 Excavation of Pole Pits in Hard Soil (common to all size of poles) 4 Excavation of Pole Pits in rocky area (common to all size of poles) by blasting / Manual 5 Excavation of Stay pit of 4.5 to 5 depth using JCB / Manual (0.95 X 0.6 X 1.2 M) 6 Excavation of Stay pit in Hard rock soil (0.95 X 0.6 X 1.2 M) 7 Erection of RCC, REC, PSC poles upto 8.00m length by using Crane / Manual 8 Erection of RCC, REC, PSC poles above 8.00m length by using Crane / Manual 9 Erection of metal supports above 9m / RSJ / Rail Pole/Tubular Poles 10 Erection of stay set complete with fixing up stay wire Eye, Bow, Guy Shackle, Binding etc. excluding stay pit excavation 11 Erection of additional Stay in the same stay rod, excluding excavation of stay pit and burial of stay rod. 12 Fixing of V cross arm 3.5feet 13 Fixing of V cross arm4.5 feet 14 Fixing ofV cross arm5.0 feet 15 Fixing of Fixing of LT S phase cross arm 16 Fixing of Fixing of LT 3 phase cross arm 17 Fixing of Fixing of HT / LT Ti fitting 18 Fixing of Fixing of HT PIN insulator with Pin 11 kv 19 Fixing of HT PIN insulator with Pin 22 kv 20 Fixing of HT PIN insulator with Pin 33 kv 21 Fixing of LT PIN insulator with pin 22 Fixing of HT strain disc 11 KV with Metal parts 23 Fixing of HT strain disc 22 KV with Metal parts 24 Fixing of HT strain disc 33 KV with Metal parts 25 Fixing of Tapping cross arm 26 Fixing of Two Tapping cross arm per cut point upto 33 KV line including fixing of Discs,insulators and Jumpering etc.. 27 Fixing of Top Channel 28 Fixing & erection of Cross bracing 29 Fixing of shackle with Metal parts 30 Fixing of Aluminium knob 31 Fixing of HT LAS (3 Nos.) 32 Paving and stringing of conductors of sizes upto 7/2.59 mm ACSR or other equivalent conductor 33 Paving and stringing of conductors ofabove7/2.59 mm ACSR or other equivalent conductor upto 7/3.35mm ACSR or other equivalent conductor 34 Paving and stringing of conductors of7/4.09mm ACSR or other equivalent conductor 35 Paving and stringing of conductors of7/4.72 mm Dog Conductor or other equivalent conductor 36 Releasing and reerection (resagging) of one run of all sizes of conductor 37 Complete Erection of Double Pole Distribution Transformer structureas per TNEB standard likepole pit excavation & erection, stay pit excavation and erection, feeders arrangement, Open type fuse unit,HT / LT LAS and jumpering, 3 Nos Earth pits with earth trough, concreting,coping, Colour washing of RCC poles, Painting of Structure Materials (including cost of paint(red oxide,Aluminium) and distember), Danger Board fixing etc.. (excludingerection of Distribution Transformer) 38 Erection of11 KV/22 KV single pole Structure includingerection of DT complete with centre support with pole pit excavation & erection, stay pit excavation and erection, feeders arrangement, Open type fuse unit, HT /LT LAS and jumpering, 3Nos earth pits with earth trough, structure earthing complete, concerting,coping, colour washing of RCC poles, painting of structure materials (including cost of paint (red oxide,aluminum)and distermber), danger board fixing etc..(exculding erection of distribution transformer) (Data as per Annexure III) 39 Erection of distribution transformer inculding loading of distribution transformer at stores and erection at structure or vice versa. Upto 25 KVA distribution transformer/metering set. 40 Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa. Upto 25 KVA to 100 KVA 41 Failed DT replacement below 100 KVA 42 Failed DT replacement 100 KVA and above 43 Erection of DP structure with stay as per TNEB standard including fixing of top channel, cross bracing, HG Fuse Unit, concreting, painting, colour washing etc., With 11 KV AB switch using all types of poles of size 9.14 m and above length 44 Erection of DP structure with stay as per TNEB standard with 22/33 KV AB switch using all types of poles of size 9.14 m and above lenth including fixing of top channel, cross bracing, HG Fuse Unit, concreting, painting, colour washing etc., 45 Erection of single pole DP with completewith earthing 46 Concreting with 1:4:8 mix using 40 mm Jelly including curing(Material + labour)Mass concreting of poles with coping 0.6MX 0.45MX1.25M 47 Concreting with 1:4:8 mix using 40 mm Jelly including curing(Material + labour)Sleeveconcreting with coping 0.6MX 0.6MX0.3M 48 Concreting with 1:4:8 mix using 40 mm Jelly including curing(Material + labour)Stay concreting with coping 0.3M dia and 0.75 long 49 Earthing of poles with GI wires 4 or 6 SWG by coil earthing 50 Provision of spike with earthing arrangement including material (other than clamps & GI wire ) and fabrication 51 Pipie earthing including excavation of earth pit and fixing earth pipe 3 m length 52 Replacing the corroded earth pipes of transformer structure and replacing the earth wire completely with aluminium lugs for termination 53 Replacement of corroded earth pipe 54 Erection of fourth Earth pipe including earthing 55 Loading& unloading of REC, RCC, PSC pole upto 8.00 m length 56 Loading& unloading of All REC, RCC pole above 8.00 m length 57 Loading of Conductor with ramp 58 Unloading of Conductor with ramp 59 Loading of Iron & Steel 60 Unloading of Iron & Steel 61 Loading of line materials (Including Stacking except conductor drum & scrap material) 62 Unloading of line materials (Including Stacking except conductor drum & scrap material) 63 Loading of 11 KV disc 64 Unloading of 11 KV disc 65 Loading of LT Pin insulator shackle, guy shackle, LT Pin, Metal parts, HT pin etc., 66 Unloading of LT Pin insulator shackle, guy shackle, LT Pin, Metal parts, HT pin etc., 67 Loading of scrap materials 68 Unloading of scrap materials 69 Transportation of all types and sizes of poles and other associated materials from Road side to pole pit and vice versa upto 1.0 KM 70 Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading) For a lead upto 5 KM 71 Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading) Above 5 KM of lead of every KM 72 Transporting of Distribution Transformer / Line materials from stores to office / site upto 10KM distance by engaging 1 Ton capacity Minidor (Lorry) 73 Transporting of Distribution Transformer / Line materials from stores to office / site Above 10 KM distance by engaging 1 Ton capacity Minidor (Lorry) 74 Provision of guarding with two numbers earth pits excluding stay set erection - gradle guarding including earthing and earth pit excavation without material 75 Dismantling of RCC, REC, PSC & metal pole of all sizes including the closing of the pit 76 Dismantling of stay set complete including stay rod 77 Dismantling of conductor ofupto 7/3.35 including transporting the conductors to the nearest road side and stocking in coils 78 Dismantling of conductor ofabove 7/3.35 including transporting the conductors to the nearest road side and stocking in coils 79 Dismantling of Transformer structure materials complete set and transporting the same from the location to the road side 80 Releasing of LT S ph X Arm with all accessories 81 Relaasing of LT 3 ph X Arm with all accessories 82 Releasing of 3 - 6 V Cross Arm/Tapping channal/GuardingX Arm with all accessories 83 Releasing of 4 - 6 andV Cross Arm with all accessories 84 Releasing of5V Cross Arm with all accessories 85 Releasing of Distn.Tr. Only at field - Upto 25 KVA / Metering set 86 Releasing of Distn.Tr. Only at field- Above 25 KVA and upto 100KVA 87 Dismantling of structure poles 88 Painting of iron poles up to 36 ft length with double coats including cost of paint 89 Painting of iron poles up to 40 ft 200/100 length with double coats including cost of paint 90 Painting of structure materials distribution transformers with aluminium paint of structure poles and writing of transformer details (Paint to be supplied by Department) 91 Labour charges for alteration of back clamp 92 Labour charges for alteration of Stay clamp 93 Providing of holes all size angles/Channel upto 3/4 94 Providing of holes all size angles/Channel above 3/4 95 Clearing of tree branches of coconut tree 96 Clearing of tree branches of Neem, Tamarind, Country tree 97 Clearing of karruvelam 98 Converting pin point into cut point in HT Lines 99 Converting pin point into cut point in LT Lines (single / Three phase) 100 Resagging of lines for all sizes cut point location 101 Set right of leaning poles both HT & LT (Pin point ) 102 Set right of leaning poles both HT & LT ( Cutpoint) 103 Replacement of Guy Shackle only in Existing Stay 104 Replacement of 11KV Polymer Pin Insulator 105 Replacement of 22KV Polymer Pin Insulator 106 Replacement of 33KV Polymer Pin Insulator 107 Replacement of 11KV Disc 108 Replacement of 22KV Disc 109 Fencing of Distribution Transformer Structure at Road side- Fabrication and Erection including all materials (Chain link fencing)
Contract Date: May 26, 2026 Contract Value : 25.00 Lakh
Boards / Undertakings / PSU No of Bidders 2
45.
Public Administrative Department #11176954 AOC
Tender For Annual Plan-Dp Pkd 2025-26 Ghs Thenkurissi In Thenkurissi Gp--1 Ghs Building Maintenance 1.001 15.31:Dismantling Tiled Roofing With Battens, Boarding Etc. Complete Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. 1.002 15.14.1:Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead:Of Sectional Area 40 Square Centimetres And Above 1.003 10.16.1:Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Welded Type Tubes 1.004 Od388171/2025-2026:Departmental Ridge Tile- Laying On Roof Pressed Clay Tile Ridge (Mangalore Tile) Of 20 Mm Thickness And Of Approved Pattern On Steel Frame Work Complete (Steel Frame Work To Be Paid Separately ). 1.005 Od388172/2025-2026:Departmental Tile- Fixing On Roof Pressed Clay Tile (Mangalore Tile) Of 20 Mm Nominal Thickness And Of Approved Size And As Per Approved Pattern On Steel Frame Work Complete (Steel Frame Work To Be Paid Separately) 1.006 12.48:Providing & Fixing On Roof Pressed Clay Tile (Mangalore Tile) Of 20 Mm Nominal Thickness And Of Approved Size And As Per Approved Pattern On Steel Frame Work Complete (Steel Frame Work To Be Paid Separately) 1.007 12.49:Providing & Laying On Roof Pressed Clay Tile Ridge (Mangalore Tile) Of 20 Mm Thickness And Of Approved Pattern On Steel Frame Work Complete (Steel Frame Work To Be Paid Separately ). 1.008 15.7.4:Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 1.009 2.8.1:Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil 1.01 Od388189/2025-2026:60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site 1.011 7.1.1:Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Up To Plinth Level With:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 1.012 5.9.2:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 1.013 5.1.2:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 1.014 5.22.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 1.015 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 1.016 4.1.8:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 1.017 13.1.2:12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 1.018 13.88:Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 1.019 13.111.2:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade :Old Work (One Or More Coat Applied @ 0.90 Ltr/10 Sqm). 1.02 12.50:Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.021 Od388221/2025-2026:Supplying And Fixing 160Mm Dia Pvc Rain Water Gutter Semi Circular Section Including Fitting With 32Mmx5Mm Ms Flat Supporters At 1M Interval Etc Complete 1.022 50.6.1.5:Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made) Of Size 30X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 1.023 2.33.1:Felling Trees Of The Girth (Measured At A Height Of 1 M Above Ground Level) Including Cutting Of Trunks And Branches, Removing The Roots And Stacking Of Serviceable Material And Disposal Of Unserviceable Material.Beyound 30 Cm Girth Up To And Including 60 Cm Girth 1.024 2.33.2:Felling Trees Of The Girth (Measured At A Height Of 1 M Above Ground Level) Including Cutting Of Trunks And Branches, Removing The Roots And Stacking Of Serviceable Material And Disposal Of Unserviceable Material.Beyound 60 Cm Girth Up To And Including 120 Cm Girth
Contract Date: May 26, 2026 Contract Value : 14.20 Lakh
Government Departments No of Bidders 2
46.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
47.
Educational and Research Institute #11161433 Price Bid
Procurement Of Equipment, Instruments, Machinery, Tools Etc. Related To Laboratories And Workshops Of Electronics And Telecommunication Engg., Engineering Physics, Engineering Mechanics Of Mirik Government Polytechnic, Mirik, Dist. Darjeeling, 734214 , Spherometer (Screw Pitch 0.05 Mm And Lc 0.005 Mm) , Concave Mirror (Focal Length 20 Cm) , Convex Mirror (Focal Length 20 Cm) , Concave Surface (Focal Length 20 Cm Diameter 50 Mm) , Hooks Law Apparatus (Consisting Of 30 Cm Long Mirror Scale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand) , Mercury (Distilled Liquid Mercury, Grade Std.-Biotech Grade) , Flywheel Apparatus (Thickness: 4.4 Cm Diameter :20 Cm) , Cantilever (Length 100 Cm, Hook At One End, C Clamp) , Light Weight Hanger (Metal Slotted Weight Mechanics Physics Experiment Equipment Set With Hook With Weight Of Each Mass Of The Order Of 50Gm Or 100 Gm) , Inverse Square Law Apparatus (Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter) , Stopwatch (Digital Stopwatch With Ms Count) , High Resistance Box (Resistance Box Plug With 1 To 10 K Ohm Resistance) , Winch Crab Single Purchase With Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut.String, Weight Box With Pan. ] , Winch Crab Double Purchase Without Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut. ] , Worm And Worm Wheel Single Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Worm And Worm Wheel Double Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Wheel & Axle Simple Without Weight [Standard Setup For Lab.] , Simple Screw Jack With Weight [Experiment Set Up Screw Jack ( Weights)All Metallic Construction Accurately Machine Cut Screw With A Pitch Of 5 Mm Carrying A Double Fanged Turn Table Of About 20 Cm Diameter. Fitted On A Heavy Cast Iron Base And Complete With Two Adjustable Pulleys, Cord And Hook. Weights Are Included.] , Combined Inclined Plane & Friction Slide Apparatus Iron Base & With Weight [Standard Setup For Lab.] , Parallel Forces Apparatus [Experiment Set Up Simple Supported Best Type Supported At Its End. For Verification Of Condition Of Equilibrium Of Parallel Forces, Law Of Lever & Forces On Beam Etc. Consisting Of Two Compression Thrust Type 10 Kg Tubular Spring Balances Fixed On Wooden Polished Board, A Wooden Beam With Steel Back Plate. Complete With Two Strups, Hooks & Two 10Kg Weights. ] , To Verify Lami’S Theorem [Gravesand Apparatusboard: Wooden With Metal Base Pulley: Z-Pullies (2 Nos) With Adjustable Distance Weight Set: 5X50 G (3 Sets). ] , Simple Jib Crane Apparatus Iron Stand With Weight [Experiment Set Upwith Consisting Of A Tubular Compression Balance, Pivoted About An Axis Fitted To The Base. The Tie Chain Has An Adjustable Angle Bracket And Fitted With A 10Kg Extension Balance. Completion Wooden Base With 1.2 Meter Jib. With Weights. ] , Mini Drafter, T Square, Protractor, Set Squares, Compass, Divider [Made Out Of Wood. To Be Used In Chalk Board] , Model Of Geometric Constriction (Solid Cube, Solid Primed, Cylinder, Cone, Hexagon, Tetrahedron ) [Made Out Of Wood. To Be Used In Chalk Board] , Amplitude Modulation And Demodulation Trainer Kit [Message Signal:100 Hz To 2.8 Khz, Carrier Signal 28 Khz To 108 Khz,Modulation : Balanced Modulator, Amplifier : Op Amp Based, Demodulation : Diode Detector & Lpf(6Th Order)] , Frequency Modulation Anddemodulation Kit [On-Board Message Signal With Variable Amp/Freq,On Board Carrier Signal Fm Modulation Using Xr 2206Ic,Demodulation Using Pll Detector And Lpf 4Th Order Lpf,Internal Power Supply +5V , +12V/ 500 Ma] , Super Heterodyne Am Radio Receiver Trainer Kit To Measure Sensitivity, Selectivity And Fidelity [On Board Variable Capacitor Tuning,Receiving Antenna,Local Oscillator,Bfo, Rf Amplifier, Mixer,If Amplifiers, Detectors, Agc,Audio O/P Amplifier, Speaker.Frequency Range: 400Khz To 1700Khz,If Frequency: 455 Khz.] , Pam, Pwm And Ppm Modulation And Demodulation Trainer Kit [Provides Sine Waveform Output Of 250Hz, 500Hz, 1 Khz, And 2 Khz With Amplitude Adjustments Of 0 - 5Vp-P. Switch Selectable Sampling Clock Of 4, 8, 16, 32 Khz. On-Board Features Analog Sample Circuit/Output, Sample & Hold Circuit/Output, Flat Top Circuit/Output, 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz.] , Analog Signal Sampling & Reconstruction Trainer Kit [±15V D.C. At 100Ma, Ic Regulated Power Supply, A.F. Signal Generator For Modulating Signal.Sampling Clock Generator To Provide Sampling Clock And Gate Pulse. Modulator Circuit For Flat-Top Natural And S/H Circuit. Demodulator Circuit To Reconstruct Input (Sinewave)] , Telephone Receiver Trainer Kit [Line In Section : One Dot Line Connection Port.Handset : One Handset Connection Port. Keyboard : 4X3 Matrix Keyboard.Dialer : Tone And Pulse. Facilities : Redial Up To 32 Digits, Mute, Redial, Flash, Pause Switches.Indicators : Line In, Hook, Tone And Ringer, Call Mute Section.Control : Ringer Volume Control, Ringer Speed Control.Speech Path : Fully Non-Blocking.Dial Pulse Ratio : 10 Pps + / - 10%.] , 100Mhz Digital Oscilloscope [Bandwidth: 100 Mhz, 2 Analog Channels+ Ext With Probes Included Rise Time: =3.5 Ns, Real-Time Sample Rate Of 1 Gsa/S 1% Dc Gain Accuracy Should Support Rs232/Uart, I2c And Spi Bus Triggers And Decodes Usb And Ethernet Connectivity] , 30Mhz Analog Cro [Dual Trace Dual Channel Oscilloscope. Bandwidth: 20Mhz. Full Bandwidth Sweeping Circuit , Tv-H / Tv-V Synchronization And Trigger-Lock To Observe All Kinds Of Signals Stably. Y Deflection Operation: Y1, Y2, Alt, Chop, Add, Mode.Horizontal Sweep Mode: Auto, Trig, Lock, Single.X-Y Mode Input: X-Axis Yi And Y-Axis Y2.] , 2 Mhz Function Generator [Frequency: 1Hz – 2 Mhz Sine, Square, Triangle, Ttl Output] , Digital Storage Oscilloscope (100 Mhz) [Bandwidth 100 Mhz, Channels: 2+, Display: Tft Color Lcd Of Suitable Size (Capacitive Touchscreen). Sampling Rate: 1 Gsa/S Real Time, Sampling Mode: Normal, Average (2, 4, 8, 16, 32, 64, 128, 256), Peak Detect. Mathematics: A+B, A-B, A×B, Fft (Fast Fourier Transform). Fft Windows: Rectangle, Hanning, Hamming, Blackman. Auto Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1-2 (Rise), Delay1-2(Fall) ] , Trainer Kit For Rectifier With And Without Capacitor Filter For : — (A) Half-Wave Rectifier, (B) Full-Wave Rectifier, (C) Bridge Rectifier [Transformer Rating : 9-0-9V/200Ma, Rectifiers : Half Wave; Full Wave - Bridge, Center Tapped Rectifier,On-Board Dc Voltmeter : 0 - 20V,On-Board Ac Voltmeter : 0 - 20V,Load : Variable Resistive Load 10K,Filter Circuit : In-Built- Capacitor (3Nos.),In-Built- Inductor (1No.),Input Line Voltage : 230V Ac ± 10%, 50Hz] , Push-Pull Amplifier Trainer Kit [I.C Regulated Power Supply : +6 V.Digital Ac Voltmeter: 0 – 20 V.Digital Ac Milliammeter : 0 – 200 Ma.Set Of Resistances.Set Of Capacitors.Two Transistors Cl 100 And Ck 100.Connecting Wire.] , Fet Characteristics Trainer Kit [Variable Dc Regulated Power Supply Of 0-5V At 250Ma. Dual Range Dc Voltmeter Of 1.5V/15V.Dc Ammeter Of 0-20Ma.] , To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Bandwidth, Midband Gain, Input Impedance And Output Impedance For: (A) Single-Stage Amplifier (B) Double-Stage Amplifier [Sine Wave Oscillator 15Hz To 150Khz In Four Ranges With Amplifier & Amplitude Adjustable.Three Decade Resistances Bank In Steps Of 1K, 10K & 100K Per Steps Total Step 30.Two Pnp Transistors.] , Mosfet Characteristics Trainer Kit [On Board Ammeter And Voltmeter,Dual Variable Dc Power Supplies,On Board Mosfet And Fet With Resistors To Perform Experiments] , To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — (A) C-E Configuration, (B) C-C Configuration, (C) C-B Configuration [Power Supply 1) 0-1V Dc 2) 0-10V Dc.Meters Dc 65Mm Four Dial V, V , Ma Ua/ Ma.Transistor Cl100/ Similar] , Component Development System [Power Supplies On Boards 0-15 V And 0-30 V, 250 Ma Each Variable.Fixed Dc Regulated Power Supplies 15 V/250 Ma And 5 V/250 Ma.Ac Power Supply 15-0-15 V For Rectifier Applications.Various Components On The Trainer Set. ] , Kcl & Kvl Trainer Kit [Two Dc Ic Regulated Power Supplies 0-12 V/150 Ma, Two Mr65 Square/Digital Meters For Voltage & Current Measurement, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Power Cords 230 V, 50 Hz] , Thevenin’S And Norton’S Theorems Trainer Kit [Power Supply 2?3?0?V, Regulated & Short Circuit Proof Variable Dc Voltage Source – 01 No. Fixed Resistance Of Different Values. Dc Voltmeter.Dc Ammeter. Glass Fuse For Short Circuit Protection. On/Off Switch With Indication Light. Patch Cords Suitable To The Terminals With Board For Easy Interconnection.All Above Accessories Will Be Fitted On Bakelite Sheet Fixed On Box.] , Superposition Theorem Trainer Kit [Instrument Comprises Of Two Fixed Output Dc Regulated Power Suppliesof 12V & 5V At 500 Ma Current, Three Moving Coilmeter, Circuit Diagram Printed On The Front Panel & Connections Ofsupplies, Meter & Resistances Brought Out At 4Mm Sockets. ] , Maximum Power Transfer Theorem Trainer Kit [Ammeter 30Ma Dc. Voltmeter 12V Dc. Power Supplies: Dc Supply Ic Regulated 0-12V Dc, 150Ma. Operated On Mains Power 230V, 50Hz +10% Components Are Mounted On The Panels Are: Resistances 2Watts Variable Resistor Voltage Control Through Potentiometer. Fuse For Short Circuit Protection. Patch Cords 4Mm.] , Reciprocity Theorem Trainer Kit [Instrument Comprises Of One Fixed Output Dc Power Supply Of 12V At 300 Ma Current, Two Moving Coil Meters, Circuit Diagram Printed On The Fornt Panel & Connections Of Supplies, Meters & Resistances Brought On Terminals.] , Series And Parallel Resonant Circuit Trainer Kit [Analog Meters: Ammeter 20Ma Ac. Voltmeter 20V Ac. Components Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch.] , Low Pass And High Pass Filter( Rc & Lc) Constant K Type Trainer Kit [Instrument Comprises Low Pass Circuit Rc Type Instrument Comprises Low Pass Circuit Lc Type Instrument Comprises High Pass Circuit Rc Type Instrument Comprises High Pass Circuit Lc Type Instrument Fitted In Highly Shockproof Plastics Box] , T And ? Type Attenuator Trainer Kit [Instrument Comprises Ofdc Ic Regulated Power Supplies 0-15V/150Ma. Two Mr65 Square / Digital / Round Meters For Voltage & Current Measurement. T And Pie Network Provided On The Board. Variable Resistor Using Band Switch Is Mounted On The Board. Instrument Fitted In Highly Shockproof Plastics Box. Sufficient No Of 4Mm Patch Cords For Interconnection Instruction Manual For Student Workbook. Power Cords 230V, 50Hz] , To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: (A) Open Termination, (B) Short Termination, And © Matched Termination. [Transmission Line : Coaxial Cable 100M ( 25M X 4 Nos) Impedance Matching Resistance : 0 To 100 ( 02 Nos ) Test Generator : 1. Sine Wave : 4 Khz To 4 Mhz. 2. Square Wave : 10 Khz. Interconnections : 4 Mm Sockets On All Input / Output Connections. Test Points : 10 On Board Circuit Mimic : Illustrates Functional Blocks For Ease Of Experimentation Power Requirement : 230V 10% 50Hz, 1 Ac. Accessories Provided : I. Set Of Patch Cords. Ii. Bnc To Bnc Cable. Iii. Bnc To Crocodile. Iv. Detailed Instruction Manual.] , Digital Trainer Kit (Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor.) [Dc +5V , 400Ma; Dc +12V, 250Ma; Dc -12 V, 250Ma, Dc0 To + 30V: Variable 100Ma,Ac Output: 12V-Ct-12V, 150Ma; Logic Data 8-Bit Debounced Set/Clear Ttl Output With Bicolour Led; Clock Generator I Hz To 200Khz Variable & Manual, Ttl & /Ttl(Complement) With Bicolour Led;Logic Probes 8-Bit 3-State Led Display High, Low, High Impedance; Function Generator Sine, Square, Triangle, 1 Hz To 250 Khz;Bread Boards : 3 X 820 Tie-Points; Total Short Circuit Protection From Any To Any Point On Board] , Complete Setup To Implement The Truth Table Of Encoder,Decoder, Multiplexer And De-Multiplexer. [The Trainer Kit Should Be Able To Verify The Truth Tables Of Truth Table Ofencoder,Decoder, Multiplexer And De-Multiplexer.] , Complete Setup To Design/Construct Parity Generator, Checker And Comparator. [Industry Standard Specification To Perform Relevant Experiments. ] , Flip Flop Trainer Kit [Kit For Verification Of Jk, Sr, D, And T Flip-Flop Truth Tables] , Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design / Construct Programmable Up/Down Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design Controlled Shift Register And Study Their Function. [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Study Different Memory Ics [Industry Standard Specification To Perform Relevant Experiments. ] , A/D & D/A Converter Trainer [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Interface Ttl And Cmos Ics. [Industry Standard Specification To Perform Relevant Experiments. ] , 8051 Trainer Kit [Operating Frequency : 10Mhz Crystal,40-Pin Ic Base | 40Pin-Zif Socket,2×16 Char Lcd Display,32 I/O Pins,32Kb-Sram,32Kb-Eeprom.] , Ct-31/51 Or 8031/51 Microcontroller Trainer Kit With Led Display, Usb Interface & Inbuilt Power Supply [Operating At 10/12 Mhz, On Board 8K Ram,8/16K Bytes Of Eeprom,48 I/O Lines,Hexadecimal Keyboard And Six Seven Segment Displays,Rs-232C Interface,Usb Interface] , Ct-31/51Lcdadu8031/51 Microcontroller Trainer With Lcd Display, Usb Interface, Adc, Dac& Inbuilt Power Supply [Trainer Based On 8051/89C52 Microcontroller.On Board 32K Ram.64 K Bytes Of Eeprom.20 X 2 Lcd Display.48 I/O Lines. Onboard Adc & Dac.] , Adc Interface Module [Usb Interface, Adc Module Module 10 Channel 12Bit Ad Sampling Data Acquisition Stm32 Uart Communication Adc Module] , Dac Interface Module [Operating Voltage 2.7-5.5 V. Interface Type I2c. Resolution 12 Bits.] , Lcd Display Module [Display Contents :16 * 2 Characters (5*8 Dots ). Lcd Size :80 X 36 Mm .Lcd Thickness :9.5 Mm.] , Keyboard Interface Module [5X4 Keys Matrix Keyboard. ] , Dc Motor Controller Module [Driver Module : L298n. Motor Supply Voltage (Max.): 46V.Motor Supply Current (Max.): 2A. ] , Stepper Motor Controller Interface Module [Robocraze Stepper Motor(28Ybj-48 Dc 5V 4 Phase 5 Wire) + Uln2003 Driver Board Compatible With Arduino] , Trafic Light Controller Module [Led Traffic Lights Signal Module/Digital Signal Output Traffic Light Module] , Temperature Measurement Module [Electrobot Dht11 Digital Temperature & Humidity Sensor Module For Arduino And Rpi] , Operational Amplifier Trainer Kit ( Ic 741 ) [Inbuilt Variable/Fixed Dc Regulated Power Supplies.Output Voltages : 0-5Vdc (2Nos.) (Variable), +12Vdc (Fixed).Transistor & Components Provided Ic : 741.Transistor : Cl 100 (Npn).] , Active Filter Trainer Kit (Lpf, Hpf, Bpf) [Opamp Based First Order Lpf, Hpf, Bof Trainer Kit (Mi-A14)] , Application Of Ic555 Timer Trainer Kit (Astable & Monostable Mv) [In-Built Regulated Dc Power Supply.On Board Manual Pulse Generator For Triggering The Monostable And Bistable Circuit.Inbuilt Led Output Indicator.Symbols And Diagram Are Printed On Glass Epoxy Pcb.] , Opamp Based Oscillator Trainer Kit ((A) Hartley, (B) Colpitt, (C) Phase Shift, (D) Wein Bridge) [Op-Amp Oscillator Trainer Mi-A13. Frequency 50-60 Mhz.] , Crystal Oscillator Trainer Kit (741 Based) [Industry Standard Specification To Perform Relevant Experiments. ] , Function Generation Kit (Using Icl8038) [Icl8038 Function Signal Generator Sine Triangle Wave Kit Diy Professional K5e8.Uses Icl8038 And High-Speed Op Amp, Higher Accuracy. Low Distortion Sine Wave: 1%.] , Voltage Regulator Trainer Kit (Using Ic723) [0-35V D.C. At 250Ma, Countinously Variable Unregulated Power Supply.D.C. Milliammeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 50Ma And 250Ma.D.C. Voltmeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 10V And 40V.Ic 723 Fitted On Base.Three Potentiometers.] , Function Generator Trainer Kit [Frequency Ranges: 1? Hz To 1?0? Hz, 1?0? Hz To 1?0?0? Hz Fuse:3?5?0? Ma, Slow Blow Automation Grade: Manual Power Supply:Max 2?3?0?V Ac, 5?0? Hz +/- 1?0?%] , Maxwells Bridge Trainer Kit [The Kit Contains A Bridge With Provision For Connections Of Capacitors And An Unknown Inductor. In Built Ac Supply [ 1 Khz And 2 Vpp ] And Dc Supply [ +5 V ] On Board. Two Nos Dial Resistances [ 50 Ohm To 200 Ohm ] And [ 1 Ohm To 11 Ohm ] In Step. A Dc And Ac Null Detector Using Selector Switch. A Dial Type Variable Capacitor [ Range 0.2 Uf Ro 1.2 Uf ] And Six Nos. Unknown Inductors [ Range 1 Mh To 12 Mh ].] , Lvdt Trainer Kit [Excitation Source Built In Ac Source 2.5 Khz Sine Approx. L.V.D.T. In Non Metallic Structure. Micrometer One (For Displacement) Displacement Range 10Mm. Test Points Sockets At Different Places For Signals. Potentiometer Two For Zero & Calibration Adjust Display (Mm) 3.5 Digit Digital Power Supply Ic Regulated Phase Detection Balanced Demodulator Power Supply Short Circuit &Overload Protected Mains 230V/50Hz Ac] , Strain Gauge Trainer Kit [Strain Gauge: 4 Mounted Upon Cantilever 150X3.5X3.5Mm, Stable Dc Voltage For Strain Gauge Bridge, Opamp Based,Precision Instrumentation Amplifier With Variable Gain,Potentiometer For Zero And Calibration Adjust,3.5 Digit Display For Strain/Weight, 230V 50Hz Ac] , Temperature Transducers Kit Using (A) Rtd (Pt-100) (B) Thermistor. [12 - 0 - -12 V 500Ma To Drive Digital Integrated Circuitry. 5 - 0 - -5 V 250Ma To Drive A To D Converter Signal Conditioning And Amplifying :Analog To Digital Converter. Display : 31/2 Digit Led Display Of 200 Mv Fsd Initial Set : Single Turn Potentiometer To Set Initial Temperature ( Room Temperature) Final Set : Single Turn Potentiometer To Calibrate The Instrument ( Max. Temperature) Select : 2 Way Rotary Switch To Select Rtdand Thermistor. Power On : Rocker Switch To Control Power Supply To The Instrument.] , Calibration Of A Single-Phase Energy Meter By Phantom Loading Trainer Kit [Usage/Application: Lab Experiment Connection:4?-Mm Patch Cord Single Phase Automation Grade:Manual Power:2?0?0? W Voltage:2?2?0?-2?4?0? V] , Calibration Of A Voltmeter Using Crompton Potentiometer Trainer Kit [This Trainer Is Supplied Along With Highly Regulated Dc Power Supplies To Operate The Unit. Further To Calibrate Pmmc Meters, Necessary Ratio Boxes Also Provided. Resistors Used In This Unit For Coarse And Fine Are Very Standard Type Made Of Manganin. This Enable The User To Measure The Potential In A Circuit Close To Micro Volts. Necessary Schematic/Wiring Diagram Printed On The Panel To Follow And Conduct Experiments. User Manual And 4Mm Patch Cords Supplied. Accessories Included: Necessary Dc Power Supplies, Ratio Boxes & Galvanometer Are Provided Alongwith The Unit.] , Cro Demonstration Kit [Crt : 6Rectangular Screen With Internal Graphical 8X10 Division (1Div-1Cm) Vertical Deflection Display : Ch1, Ch2, Add, Alt & Chop Deflection Factor : 5Mv/Div To 5V/Div +3%, 1Mv/Div To 1V/Div, +5% (X5), 10 Steps Rise Time : <17.2Ns Maximum Input Voltage : 250 (Dc + Ac Peak Value) When <1Khz (250V, Dc +Ac) Input Coupling : Ac, Dc & Gnd Polarity Selection : + (Ch2 Only) Display Mode : 1, 10 & X-Y Horizontal Deflection Time Base : 0.2Us/Div To 0.2S/Div, 9 Ranges Sweep Expansion : X10 Accuracy : +3% Triggering Mode : Auto, Norm, Tv-V, Tv-H Triggering Source : Int, Line & Ext. Trigger System Auto : 20Hz-20Mhz Norm : 0.5 Div Int, 0.5 Vp-P Ext Tv-H : At Least 1 Div Or 1 Vp-P Input Impedance : 1Mohm X-Y Phase Difference : <3 Degree, Dc-50 Khz Calibration Waveform : Frequency 1Khz 2%,Voltage 0.5 V 1%, Block Diagram Printed On The Top Panel, Power Requirement: 220 Vac +10% , 50 Hz] , Q-Meter Kit Formeasurement Ofq Of Coils. [Inductance Range:199.9Mµh-19.99H Resistance Range (Ohm):19.99O-19.99M? Capacitance Range:199.9P-1.999?F Capacitance Accuracy: ±(1%±2) Digital Lcr Bridge Meter Power:220 Volts/50Hz ±10%] , Spectrum Analyzer Trainer Kit [Industry Standard Specification To Perform Relevant Experiments. ] , Public Address System Trainer Kit [To Test The Performance Of Loudspeaker And Microphone; Power Output: 100W Rms At 10% Thd Pre-Amplifier Output: 200Mv; Line Output: 1V/ 1K?; Input Channels: Mic: 2Nos; Frequency Response : 65 Hz To 15 Khz +/- 3Db Tone Controls : Bass, Treble, Master 1Control; Speaker Outputs : 4 , 8 , 16 , 70-100V Line Matching; Speakers : 2 Nos; Microphones : 2 Nos(Dynamic Microphone)] , Demonstration Kit Of Black & White Tv Trainer [To Learn The Practical Aspects And Faults Which Would Occur Often In The Black And White Tv. All The Fault Switches Are Provided To Conduct Fault And Observe The Output. The Test Points Are Provided To Determine The Voltages At The Different Sections Of The Tv And Observe The Signal Output Of The Various Sections. The Output Is Monitored On A 20” Picture Tube.] , Demonstration Kit Of Colour Pattern Generator For Colour Tv [They Should Be Able To Make Various Patterns, Including Vertical Bar Patterns, Horizontal Bar Patterns, Circle Patterns, 100% White Patterns, Check Patterns, Horizontal Bar Patterns, Vertical Bar Patterns, Color Bar Patterns, Red Color Patterns, Green Color Patterns, Blue Color Patterns,Yellow Color Patterns, Magenta Color Patterns, And Cyan Color Patterns. Learning Materials To Be Included: Theory, Procedure, Reference Results, Etc.] , Demonstration Kit Of Colour Led Tv Trainer [Display Type: Led; Hd Screen Size: 24 Inch (50Cm) Or More; Display Resolution: 1600 X 900 Pixels Or More; Video Interface: Video Input/ Vga, Hdmi And Or Dvi Input; Audio Output Power: 8W X 2; Receiving System: Pal Bg/I/Dk And Ntsc; Channel Coverage: Vhf-2-12, Uhf21-69; Catv (X~Z+2, S11s41) Mains Supply: 110-260V Ac ± 10%, 50/60Hz; Power Consumption: 35W] , Demonstration Kit Of Dth Trainer Kit [Colour Tft Lcd: 5.7” Tft Lcd; Rf Input: 950 - 2150 Mhz; Rf Output: 470 Mhz Two 862Mhz; Video Output: Pal/Ntsc; Uplink Satellite: Insat 4B; Test Points: 34 Nos.; Included Accessories: Mains Cord, Power Supply, Remote, Dish Antenna With Accessories, Lnb] , Demonstration Kit Of Photocopier [Interface Hi-Speed Usb 2.0 Copy Speed Simplex To Simplex Up To 20 Ppm In A4 (21 Ppm In Letter) Scan Method Color Cis Compatibility Twain, Wia Fault-Creating Facilities For Crum, Thermistor, Stepper Motor, Pickup Clutch, Feed Sensor, Width Sensor, Scanner Stepper Motor, Scanner Sensor, And Printer Door. Various Fault Switch With Test Points Provided On-Board.] , Demonstration Kit Of Fully Automatic Washing Machine Trainer Kit [Semi/Fully Automatic Washing Machine Mechanical Controls 30 Minutes Timer, Wash/Spin Control Atleast 6 Liter Capacity Machine Fault Switches For Wash Motor, Spin Motor, Lid Opening, Buzzer Etc All Faults Are Mounted On Pcb With Enclosure] , Demonstration Kit Of Microwave Oven Trainer Kit [Type: Solo; Capacity: >15 Ltr; Power Consumption: 600 Watt Or More: Child Lock And Alarm, Various Test Points] , Demonstration Kit Of Refrigerator [Industry Standard Specification To Perform Relevant Experiments. ] , Demonstration Kit Of Air Conditioner. [Industry Standard Specification To Perform Relevant Experiments. ] , Tdmpulse Code Modulation Trainer Kit [Crystal Frequency: 12/16 Mhz On Board Generators, 1. Adjustable Amplitude Sine Generator Of 500Hz & I Khz (Synchronised) 2. Variable Amplitude Dc Level (2 Nos.) Input Channels: Two Multiplexing: Time Division Multiplexing Modulation: Pulse Code Modulation Sync Signals: Pseudo Random Sync. Code Modulation Error Check Code: Off, Odd, Even, Hamming Operating Modes: Fast 240 Khz Channel (Approx) And Slow I Khz Channel (Approx) Pc - Pc Communication: 2 Channel Via Rs 232 Baud Rate: Selectable From 300 To 2400 Fault Switches : 8 Nos. Through 8 Way Dip Switch For Troubleshooting At Different Blocks Should Include Various Test Points] , Tdm Pulse Code Demodulation Trainer Kit [2 Channel Time Division Multiplexed Pulse Code Modulation Receiver. Fast (240 Khz/Channel Approx) And Slow (1Hz. /Channel Approx.) Mode Of Operation Pseudo Random Sync. Code Generator For Frame Synchronization. Receiver Clock Generation Using Pll. Error Detection Of None, Even, Odd, Hamming. Error Correction Using The Hamming Code Technique None, Even, Odd, Hamming Parity Selections Two Nos. Of 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz. Four Switched Faults For Fault Selection Block Description Screen Printed On Glassy Epoxy Pcb] , Fdm Transmitter / Receiver Kit [Two Variable Modulating (Sinusoidal) Input Channels With Provision Of Voice Inputs Two Dsbsc Modulators For Frequency Band Translation Of Two Test Signals Two Carrier Generators Two Sets Of Audio Input Amplifier One Adder/Transmission Amplifier Two Demodulators Two Low Pass Filters For Smooth Output] , Ask / Psk / Fsk Modulation And Demodulation Kit [The Kit Should Have An Integrated Ask / Psk / Fsk Modulation And Demodulation. Various Functional Block Diagrams Are Provided On-Board For Teaching/Training. Test Points To Visualize The Signals On Oscilloscopes] , Microwave Test Bench (Klystronbased) [Complete Klystron-Based Test Bench Study Of The Characteristics Of The Klystron Tube And To Determine Its Tuning Range, To Determine The Frequency & Wavelength In A Rectangular Waveguide Working On Te 10 Mode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , Microwave Test Bench (Gunn Based) [To Study The V-I Characteristics Of Gunn Diode, To Study The Voice Communication By Using Microwave Test Bench, To Study The Following Characteristics Of Gunn Diode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , 24 Awg Tinned Single Strand Jumper Wire Spool Blue Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Green Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Red Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Black Colour [90 Meter Spool] , Flexible Electric Wire [2 Core, Twisted Flexible, Red And Black, 0.5 Sq Mm Copper Core, 50M Length] , Soldering Wire [Flux Core, Coil Type (Wire Of 100Gm )] , Inductor 1 Mh [8X10 Mm Radial Leaded Power] , Inductor 10 Mh [8X10 Mm Radial Leaded Power] , Led Red, Green, Blue, White Colour. Fifty Numbers Of Each Colour Led. [0.5W, Through Hole Type] , Ic 7400 [Ttl Ic-Quad 2-Input Nand Gate] , Ic 7402 [Ttl Ic-Quad 2-Input Nor Gate] , Ic 7404 [Ttl Ic-Hex Inverter Gate] , Ic 7408 [Ttl Ic-Quad 2-Input And Gate] , Ic 7432 [Ttl Ic-Quad 2-Input Or Gate] , Ic 7486 [Ttl Ic-Quad 2-Input Xor Gate] , Ic 7474 [Ttl Ic-Dual D Positive Edge Triggered Flip-Flop, Asynchronous Preset And Clear] , Ic 7476 [Ttl Ic-Dual J-K Flip-Flop, Asynchronous Preset And Clear] , Ic 7490 [Ttl Ic-Decade Counter (Separate Divide-By-2 And Divide-By-5 Sections)] , Ic 7495 [Ttl Ic-4-Bit Shift Register, Parallel In, Parallel Out, Serial Input] , Ic 74200 [Ttl Ic-256-Bit Ram (256X1)] , Ic 74147 [Ttl Ic Encoder] , Ic 74138 [Ttl Ic 3 To 8 Line Decoder] , Ic74151 [Ttl Ic Multiplexer] , Ic74138 [Ttl Ic Demultiplexer] , Ic 74169 [Ttl Ic Up-Down Counter] , Ic 74180 [Ttl Ic Parity Checker/Generator] , Ic 74Ls83 [Ttl Full Adder With Carry Ic] , Ic 74330 [Ttl Ic-Pla (12 Inputs, 50 Terms, 6 Outputs)] , Ic 4077 [Cmos Ic Xnor Gate] , Ic 4001 [Cmos Ic Nor Gate] , Ic 4011 [Cmos Ic Nand Gate] , Ic 4070 [Cmos Ic Exor Gate] , Ic 4071 [Cmos Ic Or Gate] , Ic 4077 [Cmos Ic Ex-Nor Gate] , Ic 4081 [Cmos Ic And Gate] , Ic 4093 [Cmos Ic Nand Gate] , Ic74ls47 [Bcd To 7-Segment Decoder/Driver Ic (7447 Ic) Dip-16 Package] , Lts542 [7-Segment Display - Common Anode] , Lts543 [7-Segment Display - Common Cathode] , Ic Dac0808 [Dac0808 8-Bit Digital To Analog D/A Converter Ic Dip-16 Package] , Ic Adc0809 [Adc0809 8-Bit A/D Converter With 8-Channel Multiplexer Ic Dip-28 Package] , Ic723 [Voltage Regulator Ic Input Voltage Up To 40V Output Voltage Adjustable From 2 To 37V Positive Or Negative Supply Operation Series, Shunt, Switching Or Floating Operation Output Current To 150Ma Without External Pass Transistor Adjustable Current Limiting] , Icl8038 [Function Generator Ic Wide Frequency Range - 0.001Hz To 300Khz Variable Duty Cycle - 2% To 98% High Level Outputs - Ttl To 28V Simultaneous Sine, Square, And Triangle Wave Outputs] , Ad633 [Analog Multiplier Ic 4-Quadrant Multiplication Low Cost, 8-Lead Soic And Pdip Packages Complete—No External Components Required Laser-Trimmed Accuracy And Stability Total Error Within 2% Of Full Scale Differential High Impedance X And Y Inputs High Impedance Unity-Gain Summing Input Laser-Trimmed 10 V Scaling Reference] , Lm566 [Vco Ic Wide Supply Voltage Range: 10V To 24V Very Linear Modulation Characteristics High Temperature Stability Excellent Supply Voltage Rejection 10 To 1 Frequency Range With Fixed Capacitor Frequency Programmable By Means Of Current, Voltage, Resistor Or Capacitor] , Ic Ne555 [Ne555 Timer Ic Dip-8 Package, Pack(Set) Of 30 Ics] , Ic 741 Op-Amp (Dip) [741 Ic - Dip Package - General Purpose Op-Amp Ic, Pack(Set) Of 50 Op-Amps] , Transistor 2N3904 [Pack (Set) Of 20 Transistors] , Transistor Bc107b [Pack (Set) Of 20 Transistors] , Diode 1N4007 [Pack (Set) Of 50 Diodes] , Fet- Bfw10 [Pack (Set) Of 50 Field Effect Transistors] , Zener Diode 5.6V, 1W [Pack (Set) Of 20 Zener Diodes] , Potentiometer 1 K?, 10 K?,100 K? Power Rating: 1W [20 Nos Of Each Value] , Wire Stripping Pliers, 6 Inch Long [Stainless Steel, Rust Resistant.] , Long Nose Mini-Pliers [Stainless Steel, Rust Resistant.] , Resistor 33O, 56O, 68O, 82O, 100O, 120O, 200O, 220O, 270O, 330O, 390O, 470O, 680O, 1K?,1.5K?. Maximium Power Rating 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Resistor 2.2K?, 2.7K?, 3K?, 4.7K?, 5.6K?, 6.8K?, 8.2K?, 10K?, 20K?, 36K?, 56K?, 68K?, 100K?, 470K?, 1M?, 2M? Maximium Power Rating: 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Disk Ceramic Capacitor Of Values 220 Pf, 0.01 ?F, 0.024?F, 0.1?F, 0.24?F [Pack(Set) 25 Nos Of Capacitors For Each Valueh] , Disk Ceramic Capacitor Of Values 10?F(63V), 100?F, 220?F, 470?F(50V) [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Polypropylene Capacitor Of Values 0.001 ?F,0.01 ?F, 0.1 ?F, 0.22 ?F [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Tantalum Capacitor 10 ?F (25 V) [Pack(Set) Of 25 Capacitors] , Incandescent Bulb, 40W, 100W, 200 W [With Tungstenfilament And B22 Connector]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
West Bengal View Result →
48.
Public Administrative Department #11142241 AOC
Construction And Carry Out Ancillary Works For Urban Ayushman Health Temples (Uhwc) In Porta Cabins At 14 Places In The Jurisdiction Of Thane Municipal Corporation.-1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. :Means Bd.A.1 Page No.259 2 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 3 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 4 Transportation of excavated material including loading and unloading etc. complete. (c) lead up to 5 km) 5 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 6 Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. 7 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 8 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 9 Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer incharge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. 14 Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 15 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. 16 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. cover of 75 Kilogram with lid and frame fixed in cement concrete.. Spec. No. 17 Providing and laying in trenches 25 mm dai. UPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 18 Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) 19 Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 20 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 21 Supplying, erecting, testing and commissioning of minimum three and above star rated centrifugal water pump (monoblock),230 V,single phase,50 Hz,AC.supply of 0.375kw/0.5 HP with discharge 36/9 lpm for head of 6/21 m & 25 mm suction /25 mm delivery pipe on provided CC foundation as per specification no.WP.CGP. 22 Supplying, installing and testing earthing with copper earth plate 30 x 30 x 0.315 cm complete with all accessories of copper materials and recording the results as per specification no.Ea-EP Supplying, & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 Kg.capacity cartridge type conform to IS 2878/15683 complete erected with necessary clamp made from 50 x 6 mm M.S. flat with nut & bolts rounded in wall complete. Supplying, & erecting Hand dryer machine having speed jet of warm air with low noise blower to quick dry wet hands,power 1800 W,voltage 230V,50 Hz.Automatic cut off after 5-10 second. Providing,Supplying and fixing electrical meter with all necessary accessories,required cable for connection from main supply including required permission from MSEDCL,TORRENT and Local authorities.(The contractor shall submit the original receipts of payments made to MSEDCL, Torrent Power co.The payments will be made as per the actual expenses made by contractor for each permission and purchasing of electric meter.) Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying (including excavation) 50 mm outside dia double wall corrugated pipe (DWC) of HDPE for enclosing cable below ground/road surface to required depth completed Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Providing, Supplying and installation of Porta Cabin Fabricated at Factory Scope of work per cabin shall includes as follows 1. Specification mentioned as below 2. Internal and external arrangement of cabin as per drawings as attached 3. Works of Plumbing, sanitary, electrification, CCTV 4. Furniture as below a. Executive Chairs (as per sr.no.3) - 3 nos, b. Visitor chair (as per sr.no.4) - 6 no c. Two seater chair (as per sr.no.5) – 2 Nos d. Three seater chair (as per sr.no.6) – 5 Nos e. Patient Examination Couch/Table (as per sr.no.8) – 2 Nos f. Storage Cabinet (as per sr.no.9) – 1 Nos g. Table (as per sr.no.10) – 4 Nos h. Table (as per sr.no.11) – 1 Nos i. Medical Store Racks in pharmacy room (as per sr.no.12) – as per drawing j. Trash Bin (as per sr.no.13) – 6 Nos k. Seating tools (as per sr.no.7) – 6 Nos Detailed Description and Specification: Unit Size – L x B x Ht = 30 ft x 20 ft x 9 ft (Clear internal Height) Cabin should be structurally stable and suitable to meet severity of climatic conditions. Sustainable in wind condition of 55m/s- in Seismic zone IV and ambient temperature range (-) 40 degree C to (+) 50 degree C. Bottom Frame 80 x 40 x 2mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener Bottom 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Top Frame 80 x 40 x 2 mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener (Top Frame) 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Paneling Outside Outside Wall of the cabin shall be made from 16 guage GI sheet with solid color of approved shade, fitted on inside GI pipe framing making the grid of 2ft x 2ft. Paneling Inside Inside wall of the cabin shall be made from 3 MM Thk ACP sheet with aluminum foil thickness of 0.25 mm with solid color of approved shade fitted on inside Gl pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Wall Panels shall be completely insulated with Glass wool of 48 kg/m3 Density and slab thickness 50mm. Corners Pole 72 x 72 x 3.2mm GI Rectangular Hollow Pipe (Apollo Make) with black coal tar epoxy coating Plumbing Arrangement UPVC concealed internal plumbing system shall be provided with all necessary inlet and outlet points as per the Drawing. External water connection shall be Provided by TMC. Drinking Arrangement Providing and Fixing branded water purifier of make like Aquaguard, Kent, LG or equivalent with all necessary connections, fittings accessories with storage arrangement etc. complete Sanitary Fittings All plumbing and sanitary fittings such as Ceramic Western Commode with seat cover, Ceramic Indian Commode, Ceramic urinal with push pillar cock, Ceramic Wash Basin, Wash basin Push Pillar Cock shall be of brand like Kajaria, Hindware, Paryware or equivalent. All western Toilets must be equipped with jet Spray, 2 in 1 Taps and Flush Tank. Accessories for PWD persons shall be provided in all toilets. (Excluding External Sewerage Connection). Roof Outside Roof Slope 1:2 one way 126 Roof shall be made from 1.2 mm 120 GSM GI sheets of Jindal make, which shall be fully welded and sloped to avoid leakage. All the roof joints shall be covered with 75mm Butyl Vinyl Tape. Roof shall be covered with Heat Resistant paint to maintain low temperature inside the cabin. Roof Gutter Specially designed gutter section shall be provided to drain water at the single side of the cabin. This shall be made from 1.2 mm 120 GSM GI sheet Jindal make including fitting arrangement. False Ceiling False Ceiling shall be made from 3 mm Thk ACP sheet with Aluminium foil thickness of 0.25 mm with solid colour of approved shade fitted on inside GI pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Flooring Flooring shall be made from 18 mm High Strength Bison board/ Cement fibre sheet, which is covered with 2 mm PVC vinyl flooring for cabin. For toilet Cement sheet shall be covered by 10 mm thick 1 X 2 ceramic tiles which shall be fixed by using tile adhesive and cement mixture of at least 50mm Thk. Doors & Door frame Main Door Flush door 32 mm thick waterproof material with 4mm Glass as per approved design and drawing and door frame shall be made from aluminium Section. Locking arrangement along with D Handles in SS 304, door closer, door stopper etc. Door Size: 5’x 6’ Internal doors shall be sliding doors/ flush door of size as per drawing and as per the specifications decided by engineer-in charge Toilet Door and door frame shall be made from aluminium frame with 4mm Glass and ACP including locking arrangement, Handles in SS 304, Door Size: 2’-6’’ x6’ Windows Powder coated aluminium Two Track sliding windows with 4 mm tinted Glass. Size of windows as per drawings. M.S. Grill of weight @ 20 kg per sqm shall be provided to all windows/louvered window from outside. Curtains of good quality and curtain rod/track with fixtures shall be provided from inside of windows. Insulation False Ceiling and Wall Panels shall be completely insulated with Glass wool of 48 31 Providing, Supplying and installation of Porta Cabin Fabricated at Site Scope of work per cabin shall includes as follows 32 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 33 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 34 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 35 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 36 Testing :- Compressive test of C.C.Cube 37 Provide and supplying Executive Chairs A generously cushioned, molded PU seat combined with breathable mesh fabric, Crafted from strong and durable Polyamide (Nylon) featuring a reinforced mesh back, chair equipped with BIFMA Certified Class-4 Hydraulic Gas Spring and BIFMA Certified 60mm Wheel Castors. Chair having 3 years warranty (Executive chairs) / or equivalent / as Directed by Engineer Incharge. Key Features Colour : GREY / Black Material : Metal Dimensions : 64D x 61W x 119H Centimeters Size : Standard Back Style : Mesh Back Special Feature : Adjustable Lumbar, Adjustable Height, Adjustable Arm Rest, Adjustable Head Support Seat Material Type : Breathable Microfiber Cloth Covered in PU Foam 38 Providing and supplying visitor chair having size Depth- 62cm, width-55cm, height- 80cm & seat height 45 cm. (+/- 2cm ), having seat & back, shall be made up of 1.2 cm hot pressed plywood, approved tapestry upto Rs.300/m and mould polyurethane foam with P.V.C. lipping all around etc. complete. The chair shall be provided with two one piece armrest made of polypropylene. The chair shall be supported by cantilever type powder coated tubular frame dia 2.54cm x 14 B G M.S.E.R.W. tube. All aluminium steel component shall have Epoxy Polyster Powder Coated. The chair shall be Ergonimc Dry film thickness shall be more than 45 Micron. And as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in 39 Public Seating Chair. - 2 Seater Providing and Fixing 2 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish with 1 year warranty etc complete as directed by engineer in charge.. 40 Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 41 Seating tool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 42 Providing and supplying examination couch. This examination couch features an adjustable backrest that can be easily operated using a gas spring system. The twosection foam-padded top provides added comfort for patients during examinations. It is equipped with three drawers and three cabinets, offering ample storage space for medical equipment and supplies, keeping everything organized and easily accessible. A tray for the B.P. apparatus is conveniently placed near the headrest, ensuring easy access for medical professionals. The couch is finished with pre-treated epoxy powder coating, making it durable and easy to clean, while also ensuring resistance to corrosion Designed with a carrying capacity of 150-180 kg. etc complete. as directed by engineer in charge. Key Features Adjustable Backrest: The backrest is adjustable using a gas spring system, providing flexibility for various examination positions. Foam Padded, Upholstered Top: Offers comfort and support during patient examinations. Ample Storage: Equipped with three drawers and three cabinets to store medical supplies and equipment. BP Tray: A tray near the headrest for easy access to BP apparatus. 43 Providing, supplying and installing the cabinet, dimensions of 1200mm (W) x 1660mm (H) x 450mm (D) and is constructed from prime quality 0.8mm thick CRCA steel for the body panels and shelves. The shelves are adjustable in height and have a uniformly distributed load capacity of 50kg per shelf. The vertical sides feature continuous slots for mounting shelves at variable heights. The entire carcass is finished with a 50 ±10 microns epoxy polyester powder coating. The facia of the cabinet consists of metal shutters with metal borders, incorporating toughened glass panels. The handles are Dshaped in an aesthetically pleasing design with a stainless steel (SS) finish. The locking mechanism uses a metal cam lock for security. Additionally, the cabinet is equipped with adjustable levelers featuring plastic bases, allowing height adjustments of up to 15mm.This furniture is built according to the specifications and samples approved by the client. It meets the required certifications including ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, BIS standards, and is a BIFMA Gold certified member. The product comes with a 5-year warranty. Installation and other details are as directed by the engineer in charge. 44 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1060mm x D600mm x H750 mm -1 No W900mm x D300mm x H750 mm – 1 No W600mm x D450mm x H750 mm – 2 No As Directed by Engineer Incharge 45 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. Legs are made of powdered coated steel 50mmx 50mm Section. Cross Member are in CRCA steel and the Beam is made of MS of 1.5mm thickness in powder coated finish of 50 microns thickness. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1200xD700xH740mm As Directed by Engineer Incharge 46 Providing and supplying adjustable MS storage rack having size 1200 mm to 1800mm x 300 mm x 1600 mm including all transportation upto site etc complete as directed by engineer in charge. Key features 1. Material  Frame : Mild steel (MS) powder coated  Shelves: Cold-rolled steel (CRCA) or galvanized  iron (GI) 2. Angle Specifications  Size 40 x 40 x 2.50 mm  Length : Standard lengths of 6 feet, 8 feet, or 10 47 Providing and supplying trash bins with a maximum height of 450mm 35 - 40 liter, made of high-quality molded plastic for durability and ease of maintenance. The bins shall be equipped with a functional lid mechanism and shall be provided as per the approved selection and design. The work shall be carried out as directed by the Engineer-In-Charge etc complete . 48 Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. 49 Providing and Laying M60 grade cement concrete of approved mix design with avg. Flextural strength of 4.4 MPa in 3 days from R.M.C. plant incld. use of micro silica/alcofine, approved make super plastiser and retarder, fibriliated 100 % virgin polypropylene fibres, fly ash and transported by transit mixer and placing at work site. Compacting, finishing, initial curing by approved curing compound/contractors water and tarring the sides of slab with hot bitumen as specified and as directed (w/c ratio 0.28 max.). (vatta for curing will be paid separately) for Ultra thin White Topping (UTWT) pavement. etc completed. Providing second class Burnt Brick masonry with conventional/I.S .type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete. Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter made out of 4 mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity microprismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorized distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% aluminum 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) Providing Excavator (JCB JS 80 or equivalent) of 0.9 Cum etc complete Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec. One Number: As directed by Engineer- in-charge. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying Cast in situ/Ready Mix cement concrete M-15 trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete. Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. Transportation of excavated material including loading and unloading etc. complete. ( (c) lead up to 5 km) Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer in charge. Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineerin- charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer in charge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. etc
Contract Date: May 21, 2026 Contract Value : 4.09 Crore
Local Bodies No of Bidders 2
Maharashtra View Result →
49.
Water Resources and Irrigation #11140970 Technical Bid
Tender for Excavation In Foundation For Retaining, Breast Walls Etc, In All Types Of Soils And Rocks Including All Lead, Lift And Disposal Of Surplus Material As Per Direction Of Engineer - In - Charge, As Per Drawing And Technical Specifications Clause 305.1 Of Mord Specifiction , Providing Concrete For Plain/ Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 M 10 Nominal Mix (1:3:6) Including Shuttring, Centring And T &P Etc. , Plain/Reinforced Cement Concrete In Substructure Complete As Per Drawings And Technical Specification Clauses 802, 803, 1202 And 1203 Plain Cement Concrete Grade M 15 (1:2.50:5) , Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Technical Specifications Clasues 800, 1205.4 And 1205.5 Reinforced Cement Concrete M 25 Including Shuttring, Centring And T&P Etc. Raft , Providing And Laying Reinforced Cement Concrete In Superstructure As Per Drawing And Technical Specifications Clasues 800, 1205.4 And 1205.5 Reinforced Cement Concrete M 25 Including Shuttering, Centring And T&P Etc. For Wall , Providing Weepholes In Brick Masonry/Stone Masonry, Plain/Reinforced Concrete Abutment, Wing Wall, Return Wall With 100 Mm Dia Ac Pipe Extending Through The Full Width Of The Structures With Slope Of 1(V):20(H) Towards Drawing Face Complete As Per Drawing And Technical Specification Clauses 614, 709, 1204.3.7 , Supplying, Fitting, And Placing Hysd Bar Reinforcement In Superstructure Completeas Per Drawing And Technical Specifications Clauses 1002, 1010 And 1202 , Supply And Installation Of Self Driven Rock Anchor Made Of 40Cr Material With Ouler Dia Of 32 Mm And Inner Dia Of 18.5 Mm, Yield Load Carrying Capacity Of Minimum 230 Kn In Soil / Overburden Frock Suitable For Drilling Placing And Cement Grouting. Installation With All Accessories Such As 51 Mm Dia Drill Bill, Couplers, 10Mm Thick Base Plate And Nut And Bolt Complete In All Respect But Excluding The Cost Of Cement Grouting Which Will Be Paid Extra As Per Relevant Boq Item. , Grouting With Cement-Grouting Cement Slurry In Grout Holes Under Specified Pressure Forconsolidation / Contact Grouting I Ncluding Cost Of All Materials, Machinery, Labour, Redrilling Wherevernecessary, Ventilation,Lighting, Drainage And Other Ancillary Operations Etc. Complete As Per Drawing And Technical Specifications , Supply & Fixing 3D Net Including All Cost Of Labour, Material And T&P Required For Proper Completion Of Work. 3D Net Is Lightweight Three Dimensional Mat Made Of Continuous Monofilaments. 3D Net Are Made Of Three Dimensional Structure Consisting Of Uv Stabilized Non-Degradable Polypropylene/Polyethylene/Nylon Or Similar Polymer Fibres That Are Extruded Or Heat Bonded At The Contact Points To Provide A Dimensionally Stable Matrix For Soil Erosion Protection With Minimum Tensile Strength 2 Kn/M In Length Direction & 1 Kn/M In Cross Direction Having Thickness 6.5-10Mm Mass Per Unit 450-600 Gsm. , Hydroseeding Of Soil Slopes Including Mixing Of Seeds, Mulch (Meeting Performance Parameters As Mentioned In Technical Specification), Fertilizer And Soll Amendment Products If Required In Hydroseeder Machine With Water And Spraying The Mixture With 100 Psi Pressure Pump On Hilly Slopes On Exposed Soils, (End Product Must Form A Blanket Within 2 Hours Of Application, And Soil Erosion Must Be Controlled After 2 Hours Of Application) Including Maintenance- For Three Months (Watering 2-3 Times A Day After 24 Hours Of Hydrosaeding) Or Bill Propagation Of Grasses And Shrubs. , Supply & Installation Of Non-Woven Geo-Textile Having Mass/Unit Area - 250Gsm Over The Slope To Be Treated Including All Cost Of Labour, Material And T&P Required For Proper Completion Of Work. , Hand Packed Stone Filling In Back Of Wallls Including Cost Of All Materials, Royality,T&P Etc. Complete As Per Direction Of Engineer-In- Charge. , Tubular Steel Railing On Medium Weight Steel Channel (Ismc Series) 100 Mm X 50 Mm Providing, Fixing And Erecting 50 Mm Dia Steel Pipe Railing In 3 Rows Duly Painted On Medium Weight Steel Channels (Ismc Series) 100 Mm X 50 Mm, 1.2 M High Above Ground, 2 M Centreto-Centre, Complete As Per Approved Drawings Clause 1706 , Random Rubble Stone Masonry Laid In 1:5 Cement And Sand Mortar, In Breast Walls,Retaining Walls,Parapets,Scuppers,Etc. Including Supply Of All Material, Labour, T&P And Royaltiies Etc. Complete As Per Drawing And Technical Specifications Clauses 702, 704, 1202 & 1204 Of Mord Specifiction , Providing And Installing Subsurface Drainages Pipes-Perforated Pvc Pipe (Lined With Non Wovan Geotextile) Of 100 Mm Internal Diameter As Per The Drawing Etc. Complete Including The Cost Of Drilling And Directed By Engineer In Charge , Providing And Laying Of Mechanically Woven Double Twisted Hexagonal Shaped Gabions Of Galvanized Steel, Of Size 3Mx1mx1m With Two Diaphragms At 1M Interval, Having Mesh Opening 100Mmx120 Mm, Meshwire Diameter 3 Mm For Gabions, Edge/Selvedge Wire Diameter 3.9 Mm And Lacing Wire Diameter 2.2 Mm. (The Work Includes Filling Boulders In The Gabions). , Providing Concrete For Plain/ Reinforced Concrete In Open Foundations Complete As Per Drawings And Technical Specifications Clause 802, 803, 1202 & 1203 M20 (1:2:4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttarakhand View Result →
50.
Public Administrative Department #11140214 AOC
Construction 2 Nos of Toilet (i) at Hedia SSK, Atharobanki, Hediar Abad (ii) at Hedia Noboday SSK, Atharobanki (APT Rs 198185.00 for each works)under Canning-II PS- 1 Construction 2 Nos of Toilet 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. 3 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. 4 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 5 (I) Cement concrete with graded jhama khoa (30 mm size excluding shuttering)In ground floor(b) 1:3:6 proportion 6 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing andstriking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht.shall be allowed under 12 (e) for every 4 m or part thereof)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. 7 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 mI. SAIL/ TATA/RINL 8 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety 9 Brick work with 1st class bricks in cement mortar (1:6)(a) In Supur structure 10 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. 11 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (a) With 1:6 cement mortar (i)20 mm thk plaster 12 (ii) 15 mm thick plaster 13 (i) With 1:4 cement mortar(a) 10 mm thick plaster (celing) 14 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. 15 With Sand Cement Mortar (1:4)20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative (i) Wall 16 (ii) Floor 17 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. 18 Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mm x 80mm and other 100mm x 100mm both 1.20 mmin each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm)and 2 nos. of 6 mm dia and screws from both sides6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, andhire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt,tower bolt,door ring etc.In ground floor. 19 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer. 20 In Ground floor (Two Coat) 21 a) Normal Acrylic Emulsion 22 Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly : (i) Internal surface (All floors) (b) Two coats (on new works only). (i)Other than yellow, pink. 23 Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) toinside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slabincluding filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia. 24 Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding P or S trap (excluding cost of concrete for fixing). 25 (i)580 mm X 440 mm 26 Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i)450 mm X 350 mm 27 Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). (iii)150 mm 28 Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. 29 (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only] 30 ADD 18% GST 31 Add 1.00% Labour welfare cess
Contract Date: May 27, 2026 Contract Value : 3.36 Lakh
Local Bodies No of Bidders 4
West Bengal View Result →
TenderDetail
Loading tenders