View Bid Results For Transmission Scheme Tenders

We found 594 Bid Results related to transmission scheme tenders. You can find Contractor details who won transmission scheme tenders along with contract details in Bid awards announcements section.

Filters
Stage
517
49
28
Tender Publishing Platform
22
572
State / UT
23
327
80
46
31
21
20
18
11
10
8
6
3
2
2
1
1
1
1
1
1
1
1
1
Contract Value
81
192
257
64
Publish Date
1
0
0
0
0
Sector
19
322
111
79
15
11
10
9
8
7
7
3
3
2
2
1
1
1
1
1
Ownership
7
490
63
32
5
2
1
1
Within keyword
Active filters:
Showing 1–12 of 594 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
Contract Date: Jun 30, 2026 Contract Value : 793
Local Bodies No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Jun 24, 2026 Contract Value : 7.52 Lakh
Local Bodies No of Bidders 2
Contract Date: Jun 03, 2026 Contract Value : 32.94 Lakh
Government Departments No of Bidders 6
Maharashtra View Result →
Contract Date: Jun 03, 2026 Contract Value : 9.40 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
16.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: May 19, 2026 Contract Value : 9.31 Lakh
Local Bodies No of Bidders 2
24.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
26.
Banking and Finance #10837952 Price Bid
E-Tender For Selection Of Agency For Supply Of Readymade Aids/ Appliances Under Bhima Bhoi Bhinnakshyama Samarthya Abhiyan (Bbsa) Scheme , A- Aids/Appliances For Intellectual Disability And Autism , Adl Kit For 3-6 Years (Universal Cuff, Nail Cutting, Soap Holder, Button Hook, Zipper Pull, Writing Aid, Adapted Pen With Positioning Splint, Rubber Gloves, Insulated Scissors, Insulated Tumbler, Adapted Glass Holder, Wider Brim Plate, Long Handled Lever Tap.) , Teaching Learning Kit – 3-6 Yrs (1. Teaching Aids: Visual Aids, Charts, Posters, And Flashcards To Reinforce Concepts And Engage Students. 2. Manipulatives: Hands-On Materials, Such As Counting Blocks, Shapes, And Puzzles, To Promote Interactive Learning In Mathematics And Other Subjects. 3. Educational Games: Board Games, Card Games, And Interactive Activities That Make Learning Enjoyable And Foster Critical Thinking. 4. Learning Resources: Textbooks, Workbooks, Reference Materials, And Worksheets That Align With The Curriculum And Learning Objectives. 4. Multimedia Tools: Educational Videos, Digital Resources, And Interactive Software That Enhance Understanding And Retention. 5. Writing Materials: Stationery, Writing Boards, And Notebooks For Students To Practice Writing And Note-Taking. 7. Science Kits: Laboratory Equipment And Materials For Conducting Hands-On Experiments And Scientific Investigations. 8. Language Resources: Books, Audio Materials, And Language Learning Aids To Develop Language Skills. 9. Assessment Tools: Evaluation Materials, Quizzes, And Tests To Assess Student Progress And Understanding. 10. Teachers Guide: A Guidebook With Lesson Plans, Teaching Strategies, And Tips To Effectively Use The Kit Resources In The Classroom. The Teaching Learning Kit Aims To Promote Active Learning, Critical Thinking, And Creativity Among Students While Supporting Teachers In Delivering Effective Lessons. ) , Teaching Learning Kit – 7-11 Yrs. (Studies Of Science, Technology, Engineering And Mathematic (S.T.E.M.) At A Young Age. It Can Also Be A Fantastic Way To Guide Children Toward A S.T.E.M. Career. Engages Them With Hands-On Activities To Learn About Earth Science Concepts.) , Teaching Learning Kit – 12Yrs. Above (Most Comprehensive Science Kit, Stem-Based Kid, Gift Of A Lifetime, Child Bonding, Highest Standard In Toys ) , Sensory Integration Kit- 0-3 Yrs. (Sensory Wooden Toy: This Toy Contains Wooden Tongs, Spoons, Wooden Scoops, And A Wooden Cup. Kids Can Do Scooping, Pouring, Filling, Dumping, Kneading, Filling, Measuring Using Their Own Imagination. Sensory Bin Tool Toys Are Additions. ) , Sensory Integration Kit- 0-6 Yrs. (1Kg Rainbow Rice (6 Colours), 500Gms Kinetic Sand, 250Gms Slime Sand, 1 Bug-Catching Scissor, 1 Pair Jumbo Tongs, 1 Wooden Bowl, 2 Wooden Scoopers, 10 Pompoms And 10 Beads.) , Sensory Integration Kit- 12 Yrs. & Above (V-Pen, Uni-Tip, Pointed-Tip, Talk-Tip, Hickey Bite Oro-Tube, Tt-Lr, Tt-Ud And Tongue-Steer) , Mr Kit (Multi-Sensory Inclusive Educational (Msied) Kit Has Designed For Educational Purpose For Mentally Retarded Children. Depending Upon Severity Of Id, Various Tools Are Designed To Develop The Adl Practice In The Id Children.) , B. - Aids/ Appliances For Visual Disability , Smart Cane( Smart Walking Cane With Led Lights, Automatic Alarm System, Fm Radio, Usb Charging, Adjustable Walking Stick For Seniors, Men, Women) , Digital Voice Recorder (Thin, Light And Easy To Carry Voice Recorder Direct Usb Built-In For Easy Connection To Pc Up To 4Gb Of Built-In Storage, Expandable Via Micro Sd (Sdhc/Sdxc) Cards Record In Mp3/Lpcm With A High Sensitivity S- Microphone Record In Optimized Audio Capture Settings For Music Frequencies. Reduces The Impact Of By Wrong Microphone Sensitivity Settings Wider, Brighter Led To Make It Easy To Recognize When Youre Recording Supplied Aaa Battery Will Last For Up To 55 Hours. ) , Low Vision Kit ( High Power Magnification. ) , C. Aids/Appliances For Locomotor Disability , Cp Chair ( Cp Chair Cum Standing Frame Has A Wide Secure Base For Stability With Activity Table To Facilitate Learning Or Play.) , Pair Of Auxiliary Crutches (Pac-39) ( High Strength With Special Aluminium Alloy Frame Provides High Load Bearing & Stability. Anatomical & Ergonomic Hand Grip And Contoured Underarm Piece With Very Comfortable, Highly Resilient, Elastomeric Cushioning Pad. Wing Nuts For Quick, Easy, Accurate Height Adjustments. It Must Anti Slip And Grip . Easy To Adjust Height, Easy To Clean, Light Weight, Aesthetic Design, Long Functional Life And Durable.) , Pair Of Auxiliary Crutches (Pac-40) (High Strength With Special Aluminium Alloy Frame Provides High Load Bearing & Stability. Anatomical & Ergonomic Hand Grip And Contoured Underarm Piece With Very Comfortable, Highly Resilient, Elastomeric Cushioning Pad. Wing Nuts For Quick, Easy, Accurate Height Adjustments. It Must Anti Slip And Grip . Easy To Adjust Height, Easy To Clean, Light Weight, Aesthetic Design, Long Functional Life And Durable.) , Rollator ( Lightweight Aluminium Frame With Unique Features - Such As A Pu Padded Seat, A Comfortable Foam Backrest, Removable Basket And Is Easily Foldable, Dual Height Adjustment Wherein The Ground To Seat As Well As The Height Of The Handles Can Be Adjusted To Accommodate All Its Users Comfortably. Can Be Used Both In Indoor And Outdoor Areas. Comfortable And Durable Pu Seat With Removable Storage Container.) , Tricycle (Manual) * Reserved Exclusively For Odisha Based Msme / Start Ups. (Integrated Front Wheel Drive And Steering, Single Transmission, Single Chain; Accessible Height; Frame: 25.4 Mm Od And 38 Mm Od Of 1.8 Mm, Erw Quality M.S. Pipe. User Weight Up To 120 Kg; Brakes On Both Rear Wheels (A Model Is Kept In The Department; All Tricycles With Two Separate Transmissions For The Rear Wheels Shall Be Rejected).) , Walker (Adult Size) (High Load Bearing Capacity Minimum Of 100 Kg. With Seat And Wheels. Foldable, Easy To Carry, Fold And Transport. Anti-Slip And Enhanced Grip Increase Confidence Of The User. Easy To Adjust Height, Easy To Clean, Light Weight, Aesthetic Design, Long Functional Life And Durable.) , Wheel Chair Adult (High Load Bearing Capacity Minimum Of 100 Kg. Seats- Nylon & Fire Retardant With Anti – Allergic Properties, Rims– Aluminium Rims, Wheels– Studded Wheels And Polyurethane Tyres, Frames– Steel Frames And Power Coated With Glossy Finish, Plastic Components– Engineering Plastics (Nylon Grades), Brakes– Heavy Duty Brakes, Other Steel Parts –The Other Steel Parts In The Wheel Chair May Coated With Superior Quality Of Zinc/ Nickel.) , Wheel Chair With Commode Adult (Anatomical Shaped Back, Reclinable And Removable Middle Part Of The Seat, Removable Soft Pu Rear Wheels, Directional Front Wheels, Smooth Operated Brakes.) , Wheel Chair Child (Compact N Robust, User Max Weight- 60 To 80Kg, Weight- 15-20Kg.) , Commode Chair (Users Wheight-120Kg, Seat Width-46Cm, Chair Weight-8Kg Max, Adjustable Height.) , D. Aids/ Appliances For Speech & Hearing Disability , Digital Behind The Ear (Bte) Hearing Aid( Hearing Loss Fitting Range – 70 To 120 Db Or Higher Channels- 12 Or More, Hf Average Ospl-90 -119-125 Db Or Higher, Hf Average Full-On Gain (50/60 Db Input)- More Than 70 Db Gain – More Than 86 Db, Frequency Range- 300 Hz- 6000 Hz, Max. Ospl 90- Above 140 Db, Hfa Ospl 90, Total Harmonic Distortion, Etc: As Per Iec 60118/7 (2005 & Above) Standards Feedback Cancellation Programmable: Yes, 3 Or More. Noah Integration- Yes Accessories: Bte Eartip (3 Eartips), 1 Cleaning Tool, 3 Strips Of Battery (Zinc Air), Dehumidifier Kit, Remote Fine Tuning Software: Yes Warranty – 2 Years From The Date Of Issue To The Beneficiary (Not From The Date Of Supply) Immediate Onsite Service Support At The Extension Centres, In Case Of Repair. Service For The Supplied Hearing Aid And The Necessary Accessories Should Be Available In The Market For A Minimum Period Of 5 Years From The Date Of Supply.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
28.
Defence #10776168 Price Bid
Tender For Urgent Infrastructure Upgrades At Ada-Nftc; 1 Demolishing brickwork in cement mortar manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material away from the site as per directions of Engineer-in-charge. 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. And maintaining the required slight slope at the entrance for easy movement of vehicles * Nominal concrete 1:4:8 or leaner mix. 3 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for existing tiles. All dismantled materials should be taken away from the site. 4 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes away from the site as per direction given by Engineer-in-charge. 5 Dismantling G.I. pipe including stacking of dismantled pipesas per direction of Engineer in-Charge with Internal Work- Exposed on wall.All dismantled materials should be taken away from the site. 6 Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including disposal of unserviceable materialsaway from the site. 7 Dismantling/Removal of existing MS grill windows located at 1st& 2nd floor, scope includes shifting those windows to a suitable place and finishing works after removal(plastering and leveling, painting etc) 8 Charges towards removing existing UPVC window &refixing of another place cost including civil work painting etc approximate size of UPVCwindows 1.2mtrX1.5mtr. 9 Dismantling, shifting and reassembling of exciting wooden storage located at room no 14 of size 2m x 0.5m with neat and attractive finish, including transportation, shifting, labor, complete and all other details as per ADA instructions. 10 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by manual or mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge. 11 Charges towards Rental bases movable Scaffolding, installation charges include labor, loading - unloading, two time transportation. 12 Providing and laying of Cement Concrete 1:4:8 with 40 mm nominal size aggregates for flooring bed of 150mm thickness. Including the cost of all materials, labor, compaction, leveling, at all levels, leads and lifts, curing, shuttering etc complete as per ADA instructions. 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure in all shapes and sizes in with Cement mortar 1:4 (1 cement : 4 coarse sand). The rate is inclusive of cost of transportation, labour for shifting, necessary tools & machineries etc., with all leads and lifts and as directed by Engineer in charge. 14 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure with Cement mortar 1:4 (1 cement :4 coarse sand). The rate is inclusive of cost of transportation, labor for shifting, necessary tools & machineries etc., with all leads and lifts and as directed by Engineer in charge. 15 Providing and laying vitrified floor tiles of size 600x600 mm with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colors and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc complete as per ADA instructions.Including Size of Tile 600x600 mm/300mmx450mm (dadoing same as rough plastering ). 16 Providing and fixing Ist quality vitrified wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours,of any size as approved by Engineer-in-Charge, in dado, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 17 12 mm cement plaster of mix for Internal plastering with 1:4 (1 cement: 4 fine sand)etccomplete as per ADA instructions. 18 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. (Ceiling)etccomplete as per ADA instructions. 19 Rough cast plaster with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement: 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement: 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement with ordinary cement finish using ordinary cement etc complete as per ADA instructions. 20 Providing and applying two component high performance polymer modified cementitious waterproofing, FosrocNitocoat CM 210 or equivalent having minimum parameter (a) Resistance to positive water pressure bar(DIN 1048)Pt 5: 5 (50 m head of water).(b) Resistance to negative water pressure (ITM / FTM-181): 3 bar (30 m head of water).(c) Static crack accommodation: 0.9mm.(d) Abrasion resistance (ASTM D4060): Wear Index (equivalent to 40 N conc).(e) CO diffusion resistance (Taywood method) :> 50 m - after 5,000 hrs QUV2.(f) BS 6920: 1990 Effect on Water Quality.(g) Water Byelaws Scheme approved, product listing No. 0510522.(h) DIN 1048: Water Penetration Test.(i) Fire Tested to BS 476: 1987 Parts f and g.The system includes base preparation of cleaning, brushing and removal of flaky Materials, grouting the porous area with cementitious grout, proper coving between slab and wall junctions and applying FosrocNitocoat CM210 in two coats with total Consumption @ 3.8kg/M2. Coating shall be done on the Entire horizontal surface and vertical surface. 21 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high-pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer linesetccomplete as per ADA instructions. 22 Wall painting with acrylic emulsion paint of approved shade to give an even shade with two or more coats etccomplete as per ADA instructions. 23 Providing & rendering approved shade ofsynthetic enamel paint 02 or more coats over a coat of Zinc Chromate metal primer by scrapping worn-out surfaces of existing wooden doors, MS frames/ shutters / window grills, filling cracks and crevices etc., complete. All as per OEM specification and as per sample available atADA. All works to be done as per ADA Instructions. 24 French spirit polishing of approved shade with two or more coats including a coat of wood filler etc complete as per ADA instructions. 25 Supply and fixing of 4mm ACP cladding or puff panels wherever required as per directions of Engineer-in-charge. 26 Providing, fabricating & installation of wall mounted wooden storage units of depth 450 mm, made out of 18mm thick ply wood, external surface finish with 01mm thick laminate matching to the existing color& shade and all exposed side finish with teakwood beading, internal surface finished with 0.80 mm laminate, with standard hardware’s such as lock, C type PC handles, piano hinges, skirting, locking arrangement, etc. complete neat and attractive finish, including transportation, shifting, labor etc,. And as per sample available at ADA. 27 Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Two track two panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqmupto 4.00 sqm.) 28 Provision of cloth hanging board of plywood board with higher capacity cloth hangers and should match with existing laminate to maintain aesthetics, scope includes shifting of existing board to the placeas per user requirement 29 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. 30 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 31 Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting andmaking good the walls and floor wherever required etc complete as per ADA instructions.Single half stall urinal with 5 litreP.V.C. automatic flushing cistern. 32 Providing and fixing of White Vitreous China Wash basin size 550x400 mm with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require etc complete as per ADA instructions. 33 Providing, fabricationand installation of ventilators/windowmesh shutter made out of powder coated Aluminumsectionsof size 1 ½” x ¾” (medium gauge) andTataSS mesh fillerincludinganchoring to wall/ceiling,filling the gaps with silicon, transportation, labor etc complete as per sample available at ADA. 34 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ Sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/Sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. 35 Providing and fixing 100 mm sand cast Iron grating for gully trap. 36 Providing and fixing mirror of superior glass (of approved quality) of Rectangular shape 1500x450 mm with plastic moulded frame of approved make and shade with 6 mm thick hard board backing including all accessories etc complete as per ADA instructions. 37 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour with 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not less than 190 gms including all accessories etc complete as per ADA instructions. 38 Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. 39 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge etc complete as per ADA instructions. 40 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls including all accessories etc complete as per ADA instructions. 20 mm nominal dia Pipes 41 25 mm nominal dia Pipes 42 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter 43 110 mm diameter 44 Providing and fixing brass stop cock of approved quality with 15 mm nominal bore including all accessories etc complete as per ADA instructions. 45 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931 with 15 mm nominal bore including all accessories etc complete as per ADA instructions. 46 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 with 15mm nominal bore including all accessories etc complete as per ADA instructions. 47 Providing and fixing PTMT grating of approved quality and colour with Circular type of 100 mm nominal dia including all accessories etc complete as per ADA instructions. 48 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms including all accessories etc complete as per ADA instructions. 49 Providing and Fixing C.P health faucet of approved quality conforming to IS: 8931. 15mm nominal bore (jaquar make cat no: ALD -CHR-573)as directed by engineer i/charge. 50 Providing and fixing CPVC Control valve 25 mm nominal bore as per the direction of Engineer in charge. 51 Providing and fixing CPVC Control valve 40 mm nominal bore as per the direction of Engineer in charge. 52 Supply and installation of Stainless steel Tissue paper holders of approved model. 53 Providing and fixing of PVC Nahanitrap (floortrap ) of approvedqualityandmake and confirming to ISI specificationsincluding construction ofCC : 1:2:4as directedby Engineer-in – charge including all accessories etc complete as per ADA instructions. 54 Providing, fabricating & Installation of Full height Aluminum Partition including doors. All the Vertical & Horizontal members shall be powder coated AL Sections of size 65 x 40 x 1.2 mm heavy gauge forming a grid as per drawing enclosed. The partition shall be rigidly fixed to wall / Ceiling / floor, etc for stability, the filler material shall be 05 mm thick clear glass or pin head glass fixed using AL snap fit clips, rubber gaskets, etc complete as per samples available at ADA. 55 Providing & fixing interior partition of 8mm thick ply board fixed with minimum wooden support at backside between the existing ms tube frames and later pasted with approved matt finished laminates on the partition as per the approved design including labor, material, transport etc complete. 56 Supply and fixing of 0.50mm Meta cabcolor coated Roofing sheet along with necessary hardware, cap all as per specification of OEM, etc complete as per sample available at ADA. 57 Providing, fabricating and installation of MS frame structure using hollow section, angle sections and suitable anchoring nuts and bolts of ISI make incl civil work, scaffolding required for erection of structure, curing, etc, complete. 58 Supply, Installation and commissioning of recess mounted 2 x 2 36 Watts LED fitting to be fixed on ceiling by using anchor fasteners, including suitable PVC insulating copper flexible wire connectionetc, complete all as per instructions ofADA and OEM standards. 59 Supply of LED round recess mount down lighter with 9W system wattage. Housing shall be with powder coated pressure die cast aluminium alloy with corrosion resistant polyester powder coat & with extended heat sink. Diffuser/cover made of Lexan plastic material. Rated life shall be L70 @ 50000Hrs. which shall has inbuilt electrical protection like over/under voltage, short circuit, over load, open circuit &miswiring. Driver is on constant current driver output driver @ 0.6A with PF >0.9 with line voltage @ 220-240V @ 50/60Hz, driver efficiency> 85% & THD < 15%. LED Efficiency> 130 lm/W at 1W & fixture efficiency > 100Lm/W with CRI >75 with injection molded polycarbonate lens. 60 Supply of Decorative Wall light of 2 LED with 10W system wattage.Rated life shall be L70 @ 50000Hrs. which shall has inbuilt electrical protection like over/under voltage, short circuit, over load, open circuit &miswiring. Driver is on constant current driver output driver @ 0.6A with PF >0.9 with line voltage @ 220-240V @ 50/60Hz, driver efficiency> 85% & THD < 15%. LED Efficiency> 130 lm/W at 1W & fixture efficiency > 100Lm/W with CRI >75 with injection molded polycarbonate lens. Similar to Havells LUMILINE+BS10WLED865SPCSS 61 Supplying and Installation of exhaust fan of 1440rpm of 450mm (18) size with bracket blades complete for light duty suitable to operate on 230V 50Hz 62 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 63 Supply , Installation, commissioning & testing of 8 Module box to be accommodate with 01No of 10AmpsMCB & 03Nos of 5/15A power socket outlet fixed on wall (with boxes) 5A indicator switch type, housed in table as required by user. 64 Supply , Installation, commissioning & testing of 6 Module box to be accommodated with 01No of 10AmpsMCB & 02Nos of 5/15A power socket outlet fixed on wall (with boxes) 5A indicator switch type, housed in table as required by client. 65 Supply and Laying of 2.5Sqmm 3Core PVC Flexible copper cable. (For UPS points) 66 Provision of fixing of Casing/Capping of 2” x 2” box for the ups as well as raw power points on wall with suitable fixtures 67 Supply and installation of customized table :-Pre stand table of size 1800 x 900 x 750 mm.Table top- 25 mm thick action Tesa pre-laminated board.Legs: 25 mm thick PLPB with 2mm PVC edge bonding finish.With necessary hardware of EBCO company and 18 mm thick modesty. 68 Supply & installation High back Pure leather revolving chairs for officer, size approximately 76.10L x 76.10D x 114-131.50H CM Leather high back chair. 69 Supply & installation of Mid back Pure leather revolving chairs for visitor’s size approximately 76.10L x 76.10D x 96.50-114H CM Leather Mid back chair. 70 Supplying and installation of Single bed sized wooden Cot. 71 Providing and fixing diningtable consisting of 25 mm thick PLPB table topedge bounded, 25 mm thick PLPB with edge bonded End table,18 mm thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg., as per specifications, as directed by Engineer in charge (4 seater). 72 Providing wooden Dining upholstered chairs as per selection. 73 Mattresses Dimensions: 183L X 76W X 12.7T in cm Support Type and Comfort Layer: PU Foam Mattress Features: Reversible Mattress
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Apr 16, 2026 Contract Value : 9.98 Lakh
Government Departments No of Bidders 1
Madhya Pradesh View Result →
31.
Public Administrative Department #10720277 Price Bid
Tender For Sewerage Project Of Nagar Palika Parishad Betulunder Amrut 2.0; 1 SEWERAGE PROJECT OF NAGAR PALIKA PARISHAD BETULUNDER AMRUT 2.0 for more details Refer Tender document 2 Survey, Soil investigation, Design, Construction and commissioning of Sewerage System in NAGAR PALIKA PARISHAD BETUL area including.1. Providing, laying, jointing, testing and commissioning of sewerage pipeline including construction of manholes and sewer appurtenances with road restoration works complete2. Providing house sewer chambers and laterals for connecting sewer to consumer sewer lines.3. Providing House Sewer Connection for approximately 17655 Nos including construction of collecting chamber, Public toilets, and institutions etc.4. Design, construction, testing and commissioning of3 Nos Intermediate Sewage Pumping stationIPS-1of capacity of 4.97 MLD, IPS-2-5.38 MLDand IPS-3- 4.03 MLD with pumping systemsincluding all necessary civil, electromechanical and instrumentation works complete for successful completion of the project.5. Design, construction, testing and commissioning of 1 no. Sewage Treatment Plant (STP) of capacity 16.0 MLD with main pumping station (MPS) including all necessary civil, electromechanical and instrumentation works complete for successful completion of the project.6. Supply installation testing commissioning of complete Electromechanical system. which includes but not limited to suitable rating of Transformer, DG Set, substation, HT & LT transmission line, All pump motor set, all HT (VCB Panel), LT panels, all VFD’s & starter panels, APFC panels, EOT & mechanical cranes, all pipes and fittings, all valves (mechanical and motorized), earthing, cable tray arrangement etc.in line with CPHEEO requirement, complete in all respect. for intermediate pumpingstation and Sewage treatment plants.7. Preparation of maps of proposed sewerage network and property connection to be laid under the contract with GIS mapping.8. Supply installation testing and commissioning of PLC- SCADA and OCEMS for monitoring and controlling of sewerage system as per requirement of NGT guideline and PCB norms.9. Supply installation testing commissioning of complete instrumentation system applicable for STP area and IPS area as per CPHEEO manual and system requirement. 10. Operation and Maintenance of the scheme for 5 years and 5 years defect liability after successful commissioning of scope of complete works. Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
Madhya Pradesh View Result →
32.
Power #10704531 Price Bid
Preliminary Route Survey Of Transmission Lines Of Different Voltage Gradients For Gec-Ii Scheme Under Tsc-Jhansi.- 1 Preliminary / Detailed Route Survey Using Gps, Total Work Stations, Long Range Of Following Transmission Lines ( A. ) 765 Kv: 18.5 Km. ( B. ) 400 Kv: 256 Km.Under Tsc Jhansi For Gec-Ii Scheme / Projectthe Details Of Transmission Lines Is Given As Below:- 2 765 Kv Lilo Of 765 Kv Lpgcl-Fatehabad ( Agra ) Ckt Ii Line @ 765 Kv S / S Talbehat ( 18.5 Km. ) 3 400 Kv Lilo Of 400 Kv Orai-Orai Pg ( 765 ) Ckt-I Line @ 400 Kv S / S Garautha ( 53 Km. ) 4 400 Kv Lilo Of 400 Kv Orai-Orai Pg ( 765 ) Ckt-Ii Line @ 400 Kv S / S Garautha ( 53 Km. ) 5 400 Kv D / C Talbehat - Garautha Line Ontwin Htls ( 130 Km. ) 6 400 Kv Lilo Of 400 Kv Orai ( 400 ) - Banda 2Nd Ckt.@ 400 Kv Maheba ( 20 Km. ) 7 Preliminary / Detailed Route Survey Using Gps, Total Work Stations, Long Range Of Following Transmission Lines ( C ) 220 Kv: 529 Km.Under Tsc Jhansi For Gec-Ii Scheme / Projectthe Details Of Transmission Lines Is Given As Below:- 8 220 Kv Lilo Of 220 Kv Mahoba-Banda ( 400 ) Line @ 220 Kv Hamirpur ( 35 Km. ) 9 220 Kv Hamirpur ( 220 ) - Mehba ( 400 ) Line ( 100 Km. ) 10 220 Kv D / C Charkhari - Garautha ( 400 ) Line ( 67 Km. ) 11 220 Kv D / C Talbehat - Lpgcl Plant Line On Htls ( 36 Km. ) 12 220 Kv S / C Dakore - Maheba ( 400 ) Line ( 42 Km. ) 13 220 Kv S / C Lalitpur-Madawara Line ( 55 Km. ) 14 220 Kv S / C Bamaur-Garautha ( 400 ) Line ( 34 Km. ) 15 220 Kv S / C Lalitpur-Birdha Line ( 30 Km. ) 16 220 Kv S / C Bangra-Garautha ( 400 ) Line ( 45 Km. ) 17 220 Kv S / C Kabrai - Charkhari Line ( 40 Km. ) 18 220 Kv S / C Jaitpur - Charkhari Line ( 45 Km. ) 19 Preliminary / Detailed Route Survey Using Gps, Total Work Stations, Long Range Of Following Transmission Lines ( D ) 132 Kv: 196.5 Km.Under Tsc Jhansi For Gec-Ii Scheme / Projectthe Details Of Transmission Lines Is Given As Below:- 20 132 Kv Lilo Of 132 Kv Banda-Kabrai Line @ 400 Kv S / S Banda ( 1.5 Km. ) 21 132 Kv Lilo Of 132 Kv Bharua-Sarila Line @ Hamirpur ( 4 Km. ) 22 132 Kv Lilo Of 132 Kv Mahoba-Panwari-I Line @ Charkhari ( 25 Km. ) 23 132 Kv D / C Baberu - Pailani Line ( 40 Km. ) 24 132 Kv Lilo Of 132 Kv Bharua-Sarila Line @ Muskara ( 8 Km. ) 25 132 Kv S / C Kuthond - Madhogarh Line ( 36 Km. ) 26 132 Kv Lilo Of 132 Kv Panwari - Sarila Line @ Gohand ( 20 Km. ) 27 132 Kv S / C Kadaura - Hamirpur ( Patara ) Line ( 32 Km. ) 28 132 Kv D / C Madawara - Mehrauni Line ( 30 Km. ) 29 Rates Qouted By The Bidders Shall Be Without Taxes. Taxes Applicable If Any To Paid Extra
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
34.
Health and Family Welfare #10560878 Price Bid
Printing And Supply Of Iec Materials , Printing & Supply Of Iec Materials: , Poster On Hiv / Aids 17X22 , One Color , 80 Gsm Map Litho . , Poster Four Ways Of Transmission Hiv / Aids 17X22 , One Color , 80 Gsm Map Litho . , Poster Ictc Related 17X22 , One Color , 80 Gsm Map Litho . , Handbooks Of Talking Points For Peer Educators ( 1 For Each Peer Educator ) Self Help Group And Collectivization 5 . 25X3 . 75 , 120Gsm , 4 Color , 12 Pages , Flip Books ( 1 For Each Orw & Peer Educator ) * Peer Education 11X8 . 25 , 200 Gsm Art Paper , 68 Pages , 4 Colour , Woro Binding With Triangular Hardboard Stand , Folder Hiv / Aids Ke Kuchh Buniyadi Jankari Single Fold , A4 *Open Siaze 4 Color , Art Paper 100 Gsm , Sticker Basic Of Hiv / Aids 100 Gsm , 4 Color , Back Gumming 12X18 , Filip Book Condom Prayog Ke Type Samjhauta 11X5 . 25 , 200 Gsm Art Paper , 68 Pages , 4 Color Printing Boro Binding , With Trinaggular Hard Board Stand . , Brouchure Hiv / Aids Related 4 Color , A4 ( Open Singh , 2 Fold 70 Gsm Maplitho . , Pamphlet Jaan Hai To Jahan Hai Migrant Folder 4 Color , A4 ( Open Size ) , 2 Fold , 70 Gsm Maplitho , Small Booklet Jankari Ka Khajana 5 . 25X5 . 5 100 Gsm Art Paper 68 Pages 4 Color Woro Binding With Triangular Hardboard Stand . , Filip Book Hiv / Sti / Industry / Vpl-Hiv Se Bachav 11X5 . 25 , 200 Gsm Art Paper , 68 Pages , 4 Color Printing Boro Binding , With Trinaggular Hard Board Stand . , Client File Legal Size ( Office File ) With Lamination 300 Gsm 4 Color Print Art Paper ( Gatta , Specification As Psacs Is Using The File , Mini Syndromic Case Management Flowchart Size 12 . 5X9 Inch2 , Card Sheet , Color Printing , 300Gsm . , Flowchart Of Syphilis Screening And Treatment Of Pregnant Women & New Born Size 12 . 5X9 Inch2 , Card Sheet , Color Printing , 300Gsm . , Flex Banner 3X2ft . , Brochure Ek Pahel- Social Welfare Schemes 4 Color; A4 ( Open Size ) ; 2 Fold;70 Gsm , Maplitho . , Jeevan Darshika-Booklets For Plhivs Jeevan Darshika 3 . 25X4 . 5; 32 Pages ( Including Cover ) ; 4 Color; 100 Gsm Art Paper; Centre Stitch , Poster On Hiv / Aids 17X22; One Color Font - Red; 80 Gsm; Map Litho , Poster Positive Living Positive Faces ( Male And Female ) 20X30; One Color; 80 Gsm; Map Litho , Brochure Basic Information On Hiv / Aids Single Fold; A4 ( Open Size ) 4 Color , Art Paper , 100 Gsm , Poster Orphan And Vulnerable Children 17X22; 4 Color; Art Paper , 80 Gsm; Maplitho , Card Patient Treatment Record ( White Card ) 3 Fold Wood Paper ( 300 Gsm White Board ) , Durable & Good Quality , Size: 31 X 23 Cm , Inner Pocket- 1 , Six Printing Sides , White Colour , Item Should Be Durable And Of Good Quality , Patient Booklet ( Green Booklet ) No . Of Pages- 20 , Size: 21 X 15 Cm , Inner Side Paper Colour- White , Type Of Binding: Simple ( Stapled ) , Cover Page- Bottle Green Colour Card Board 13 . 2 Kg , 100 Gsm Mablitho , Diary For Blood Bank ( Field Staff ) Diary For Enter Daily Activities Along With Monthly Planner Sheets & Iec Of Blood Donation 9 . 5X7 Color Size; 2 Color; 150 Pages; Inside 20 Page; 120 Gsm Art Paper With 4 Color Printing; Maplitho Paper 80 Gsm;Cover 300 Gsm Art Paper With Lamination; , Calendars ( Posters Sheet ) Rational Use Of Blood Art Paper 120 Gsm; Top-Middle-Bottom Gumming; 17X22 , Poster Blood Donation Related 17X22; One Color; 80 Gsm; Map Litho , Brochure Blood Donation Related 4 Color; A4 ( Open Size ) ; 2 Fold;70 Gsm , Maplitho .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 14
Uttar Pradesh View Result →
35.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
36.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
37.
Health and Family Welfare #10551406 Price Bid
Tender For Remaining Electrical Work Phc Building At Sadri District Jodhpur - 1 (Integrated Elect. BSR 2021) Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18SWGHotDippedGalvanized ModularBox withearth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pinceilingrose/lampHolder/3pinconnector,screwsetc, making connections,all as per pre approved by Engineer in charge, testingetc.completeasrequired. Forspecificationofcopper Conductor,Phenolic Laminated sheets & Electrical/ Wiring accessories referChapterE-04,E-05&E -07 .For additional technicalparametersofproducts/ work, refer Annexure A attached with this BSR. 2 Medium point (up to 6 mtr.) 3 Long point(up to 10 mtr..) 4 WiringoftwincontrollightpointasperPWDspecificationfor electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopperconductor 1.1kVgrade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG Hot Dipped Galvanized Modular Box with earth terminal ,2Nos6AtwowayModularswitch,3pinceilingrose/lamp holder/ 3pinconnector,Modularfaceplatewith gridplate, screws etc,all as per pre approved by Engineer in charge,making connections,testingetc. completeasrequired. Forspecification ofcopper Conductor, PhenolicLaminated sheets&Electrical/ Wiringaccessories referChapterE-04,E-05&E-07. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Medium point (up to 6 mtr.) 5 Long point(up to 10 mtr..) 6 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification forelectricalWorkswithISI marked1.5 sq.mmnominalsizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit&itsallaccessories(J.B.,Bendsetc.),roundtiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, makingconnections,testingetc.completeasrequired. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work refer Annexure A attached with this BSR . On board 7 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1 x 1.5 sq.mm 8 3x 1.5 sq.mm 9 2 x 2.5 sq. mm. + 1x1.5sqmm 10 1 x 4.0 sq.mm 11 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 12 1 x 6.0 sq.mm 13 4 x 6.0 sq.mm 14 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 16.0 sq.mm 17 S&Ffollowingsizes(dia.)ofISImarkedMMS(IS:9537P-III) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptancetests reports byanyNABLaccreditedlabfortheconduitshallbesubmitted before execution & All as per pre approved by Engineer in charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . MMS ( IS:9537 P - III ) PVC conduit 18 25 mm 19 32 mm 20 Supplying andLaying ISImarkedP.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type Aor C,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6.0 Sq.mm 3 core flat / Round 21 Providing & Fixing of phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 75 mm dia 22 P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single pole MCB6 A to 32 A rating 24 Double pole MCB 40 A rating 25 Four pole MCB 50-63 A rating 26 Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . IP-43 Double door (single phase) 27 16 Way (16 O/G +2 I/C) 28 IP-43 Double door (Three phase) 6 Way ( 18 O/G + 8 I/C ) 29 Providing & Fixing of metal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base insheet steel( CRCA ) powed coated enclosure as per PWD specification for electrical Works conforming to Is 8623 & IEC 61439-3 (without MCB) including , all as per pre approved by Engineer in charge,making connections,, testing etc.as required .OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 A Double Pole(single phase Three pin ) 30 Providing & Fixing of recessed/surface mounting heavy duty sheet steel not less then 1.2 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . For TPN 6 way DB 31 Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Providing & Fixing of ISI marked (IS:2268-1994) gong bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 33 Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 5 step fan regulator 100 watt 2 Module 34 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 36 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 37 Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type 38 Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field- programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type Confirming to IEC 62053-21 Below 500 A 39 Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Red/yellow/Green colour 40 Blue / white Colour 41 Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA 42 Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range - 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 43 Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV 44 SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 45 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 46 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Open execution type 160 A 47 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 %& as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Armoured Cable 6.0 Sq. mm 2 core 48 10.0 Sq. mm 2 core 49 35.0 Sq. mm 4 core 50 Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. ) of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 110 / 95 mm 51 SITC of chemical Gel earthing system of Dual Pipe Technology made of with B Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second. (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts. (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell GI pipe 2000 mm long, 80 / 50 mm, Terminal 50mm x 6 mm GI Strip 52 Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 25mm x 3mm Alum. Strip 53 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 100 mm dia. 54 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start,aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to al lthe performance requirements laid down in IS 374:2019 inluding all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 55 Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR300 mm sweep(900/1400 RPM) 56 Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: Up to 457 mm size 57 P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Up to 380 mm size 58 Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 15 Ltr. 59 25 Ltr. 60 SITC of ISO Certified company made MNRE approved & confirming to IS:12933 P-1,2,3 & 5 Flat Plate Collector type solar hot water system with collector, insulated stainless steel (SS grade:304) storage tank with electrical back up with Portable Residual Current Device ( PRCD ) facility form OEM , CRCA Powder coated /MS stand for Collector & Tank etc. as required. of following capacity complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 100 litre/ day 61 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 4 LED Tube shape fixture 1 X 18/20 W 62 Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. Surface Mounting LED Downlight 18/20W 63 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attached with this BSR. Suspended Mounting/Surface Mounting 36W LED light fixture 2x2 with acrylic / prismatic front cover. 64 Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stabilization report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumenmaintained,colorRendering Index>70 andCCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . LED Street Light fixture 70 Watt 65 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fasteners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 66 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest amendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, separated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 67 Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessary connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, Un-sheilded Information Outlet 68 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single Aperture 69 Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 U wall mounted Enclosure 70 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 12 Ports 71 Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play easy setup with no configuration or no software needed, following Port fast ethernet - 8 10/100/1000 MBPS gigabit auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 24 Port 72 Supply Installationtesting&CommissioningofISOcertified manufacturer made Monoblock motor pump set ISI marked (IS:9079- 2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2- 1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, . Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 73 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 74 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest amendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord 1 Mtr 75 2 Mtr 76 Supply , Installation, Testing and Commissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accelerated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Non Invertor Type 1.5 TR with 3 star rating of BEE (ISEER not less then 3.5 ) 77 Providing & Fixing of ISI marked (IS : 15778 - 2007) Rigid CPVC drain water piping 6 kg/ cm2 with fittings like elbow, soket, Tee etc & support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 mm dia 78 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect. NABL accelerated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kVA 79 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accommodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running inch length 80 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 81 Supply , Installation, Testing and Commissioning of ISO certified company made self contained drinking water coolar with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray, minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 82 Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kg 83 Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35mm x 35mm x 5mm 84 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 A one way switch 85 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR6 A3/5 pin shuttered socket
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
38.
Health and Family Welfare #10551402 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Setrawa Block Dechu District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
39.
Communications and Information Technology  #10457552 Price Bid
Supply Installation Testing Commissioning And Equipment For Gold Ornament Cluster Supply, Installation, Testing, Commissioning And Trail Run Of Machinery And Equipment For Gold Ornament Cluster Under Mse Cdp Scheme. , Gold Cluster Ornament , Supply And Installation Of Faceting And Milling Machine (Cnc Machine) For Bangles And Wedding Bands Double Head With Variable Speed Control, Computerizes Six Axis System. Specification: Number Of Head Horizontal & Vertical 02. Type Of Main Centre Universal 03. Number Of Axis (5+2) ‘X Longitude, ‘W D-Tilting, ‘Z Vertical For Depth, ‘R 360° Horizontal Rotary For Angular Position & Machining, ‘H Horizontal Spindle, ‘V Vertical Spindle, 04. Travel Of Axis ‘X Longitude 60 Mm, ? Rotating For Job - Continuous Rotary/Index, 2 To 400 Divisions, ‘W Tilting (Semi Rotary) Degree -40° To 90°, 05. Type Of Optional Accessories For Optimum Operation. Optional Accessories Can Be Fitted For Flat And Half Round Bangles And, Bands (Rings) 06 Milling Spindle Speed Horizontal (Servo Motor) Vertical (Hf Ac Built-In Motor With Pneumatic Tool Change Water Cooled Spindle). Min. 1000 Rpm To Max. 9000 Rpm, Min. 10,000 Rpm To Max. 60,000 Rpm ‘? Rotary,07. Spindle Motor Power Vertical, Horizontal, 1.5 Kw, 0.4 Kw,08. Electrical Supply 220V Ac / 50 Hz, 09. Total Required Electrical Load 3 Kva, 10. Air (Pneumatic) Supply Dry And Oil Free Air With 6 Bar / 87 Psi And 4 Cfm /120 Lpm Flow Rate, 11. Dimension (L X W X H) 94 X 97 X 156 Cm. 37 X 38 X 61 Inch.12 Floor Space Required (L X W X H) 155 X 161.5 X 156 Cm. 61 X 63.5 X 61 Inch,13 Net Weight With Standard Accessories 327 Kg Approx., 15 Shipping Dimension With Standard Accessories (L X W X H) Box-1 - 75 X 92 X 120 Cm. 29.5 X 36 X 47 Inch, Box-2 - 119 X 122 X 181 Cm. 47 X 48 X 71 Inch., Box-3 - 32 X 63 X 42 Cm. 12.5 X 25 X 16.5 Inch. To Include Additional Supporting Machine Tools And Materials. Fully Automatic And To Include Software Installation, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Udh - 701 Vekaria Make Or Its Equivalent. , Supply And Installation Of Bangle And Ring Turning Machine Specification: 1.5 To 3 Specification: Bangle Turning Machine (Without Any Accessories)- With Standard Inside Bangle Turning Socket - 1 Pc.- With Standard Outside Bangle Turning Mandrel - 1 Pc.- Bangle Turning Tool Holder - 1 Pc. Bangle Nylon Collets Set- Set Of 33 Inside Turning Collets (Size From 2” To 3”) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Or Its Equivalent. , Supply And Installation Of Bangle And Ring Profiling Machine 2 To 3 No.S 17 To No. 49 With Bangle Stretcher /Pep Tools. Specification: Combined Double Head (Horizontal And Vertical) *Simple To Calculate Divisions Up To 120 Parts*Robust Base With Mounting Holes For Hassle Free Operating*Dual Motor (1 For Each Head) (0.17 Hp/ 2800 Rpm)*Spindles (Rpm) - Horizontal – 5600 / Vertical – 6500* Motor 0.25 Hp* Machine Dimension 76X76x82 Cm, Bangle Nylon Collets With 1 Bangle Holder For Diamond Cut Faceting, Ring Nylon Collets With 1 Ring Holder For Diamond Cut Faceting, Ball Attachment, Half Ball Collets Set Of 6, Chain Attachment And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Model Sku: 16.0701 (Bangle Ring Turning Machine) Or Its Equivalent. , Supply And Installation Of Laser Engraving Machine 12000Mm/Sec, Cooling Systemspecification: Platform - Safety Enclosure, Operating Mode - Mopa Pulse Fiber Laser, Wave Length - 1064 Nm, Pulse Frequency - Upto 2000 Khz, Output Power - 20 Watt Mopa Pulse Fibre Engine, Focusing Optics (Nm) - 100, 163, 254, Cooling Capacity - Fully Air Cooled, Heat Sink, Profile Laser (Optional) - Visible, Red Beam Pilot Laser, Laser Safety Compliance - Fda (Cdrh), Csa, Ce.With High Speed Fiber Laser Marking Technology Marking/Deep Engraving /Cutting On Precious Metals, With Dust / Fumes Collection Unit.Pulse Fiber Laser (Mopa Engines) And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: 3802 Series Laser Marker With Rotary & Laptop Of Laser Star Make From Italy Or Its Equivalent. , Supply And Installation Of Cnc Router Machine With 3D Printer With Supporting Printing Material Specification: Jewelers Engraving 3-4 Axis With Zczb Wax Printer/ Stablizer /Struller/ Chemical /Computer Set /Heater Cleaning Tools/Back Up Ups. Molding Method - Mjp, Molding Size - 294*211*144 Mm, Printing Mode - Xhd:1200*1200*1600 Dpi:16, Dimension Accuracy - + 0.04 Mm/20 Mm, Power Supply - Ac 220-240 V, 50 Hz, 3 Kw, Overall Size - 1415*790*1160 Mm, Overall, Weight - 380 Kg, Package Size - 1700 *1000*1400 Mm, Application Software - 3D Print Data Support Format - .Stl/.Slc, Operation Environment - 18-28 ° C / 30-70 % Humidity And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. , Supply And Installation Of Digital Weighing Machine - Set Of 10 Machines With Calibration Set Up Specification: Weighing Capacity: 62 G, Resolution: 0.1 Mg, Calibration: External, Display Type: Clear Reverse Backlit Lcd Display, Standard Interface: Rs -232 C Repeatability: 0.1 Mg, Weighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: A&D Japan Or Its Equivalent. , Supply And Installation Of Ball Making Machine With Full Set Of Sheet Drawing Of Pipe Making, Soldering, Sheet Striping Machine, Hammering With All Standard Accessories Specification: Power: Single Phase, 220 V, Weight: 158 Kg, Dimensions: 45 X 76 X 106 Cm Suitable For Production Of Small To Large Sized Round, Long Oval, Long Barrel Shaped Balls From Strip Or Tube By Changing Dies, Size: 1.8Mm - 8 Mm, Ac Power 2 Hp Motor, 80-100 Balls Per Minute With Oil Pump, Weight 350Kg, Material Die Steel, Suitable For Production Of Balls Or Other Shapes Chain In Small Dimensions By Changing Dies From 0.60Mm Up To 2.00Mm, Ac Power 1 Hp Motor, 80-100 Links Per Minute With Oil Pump, Weight 300Kg. (Approx), High Grade Die Steel Material. With Separate Sheet Metal Drawing Machine Setup, To Manufacture Hallow And Solid Gold Ball Shapes, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Laser Welding Machine 130 Joule Capacity With 150 Joule Cap.Specification: Source Type - Nd: Yag (Flashlamp), Wavelength - 1064 Nm Output Power (Watts) - 60 W /80 W, Maximum Peak Power - 11 Kw, Pulse Frequency - 0.5 - 50 Hz, Beam Diameter - 0.05 - 2.00 Mm, Burst /Speed Welding - Optimized To Energy Values, Max Pulse Energy - 180 J, Pulse Performance Profile Technology - Exclusive Integrated Software, Soft Touch Resonator Technology - Beam Profile Technology (Optional), Supply Circuit - 120 V Or 230 V (+ 10 %)50/60 Hzfunctionality: 1. Automatic Energy Save Mode, 2. Integrated Preventive Maintenance Alerts, 3. Multi Language System Display, 4. 99 Memory Settings, 5. Preprogrammed Application Parameters Ceramic Cavity New Technology, 6. Inbuilt Cooling System Specially Designed For Jewelry Industry, And 7. Less Maintenance And More Efficient Power Supply Technology., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Workmake/Model: Laser Star Brand Pedistal/Stablizer Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. 10 Mm (3/8 Inch) Letter & Number Punch Set (0 To 9) & 27 Letters, Type Of Product: Punch, Weight: 995 G, Size: 10 Mm, Material: Carbon Steel, Usage: Professional I.E., On Gold And Silverand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries / Kravetto Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. Material Stainless Steel, Model Name/Number Devi: Embossing Dies, Weight 50 Gm Gross Weight 70 Gm, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/ Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes)Pattern Dimensions 3Mm - 50Mm, Material D2 D3, Usage/Application Bangle Ring Jewellery Making As Per Required Designs Quantity - 400 Pieces And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern Type: Round, Pattern Dimensions: As Per Requirements, Usage/Application: Coin Making, Material Stainless Steel, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polished, Hardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Ofgold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern: Type Square, Pattern Dimensions: As Per Requirements, Usage /Application: Coin Making, Material: Bronze And Hard Ss, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polishedhardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply And Installation Of Digital Vacuum Pressure Casting Gold Melting Machine Capacity: 2.4Kg, With Digital Display And Cooling System.Fully Automatic Casting Machine Brand/ Reiacetech Wax Mono Endura / Indigenous Furnace 6 To 8 Flask Capacity/Matrix Investment Mixer 5 Flask/ Steam Machine /Ultra / De-Waxing/Water Jet/Manual Wax Injector/ Tools /Materials For Casting/ Cylinders Powder / Stabilizer Set For All The Machine And Support Materials. Specification:Power: 11 .0 Kw, Frequency: 6 Khz, Ac Line, (50/60 Hz), 3 Phase:400 V + 10%, Melting Temperature (Max): 1300 ° C, Crucible Capacity: 3 Kg Au, Crucible Volume: 208 Cm3, Flask Size (Min): 87 Mm X 127 Mm, Flask Size (Max): 120 Mm X 300 Mm, Vacuum Pump: Included , Weight: 290 Kg (639.3 Lb), Dimensions: 70 Cm X 101 Cm X 135 Cm, Inlet Water Temperature: 35 ° Cfunctionality: Vacuum Casting Machine With Auto/Manual Technology Operating Process With High Pressure Vacuum Motor. Add On Machines For Pre Casting And Post Casting: Reiacetech Wax Injector From Italy Or Its Equivalent. Ingenious Furnace 6 To 8 Flask Capacity With 4 Side Heating Capacity. Indeginous Investment Mixer 5 Flask Capacity. Steam Machine For Gold Tree Cleaning, Manual Wax Injector Ultra Sonaic Machine, Steam De-Waxing Machine, Tool And Consumables For Casting Unit, Stabilizer Set, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Melting Machine With Digital Display And Cooling System Capacity: 2Kg With Digital Display And Cooling System, Two Models With Chiller From 50 Gm To 2 Kg, Melting Capacity / Rio Grande Melting Machine With Digital Display With Graphite Crucible Sets And 50 Gm To 500 Gm Capacity (2 Or 3 Qty Required) Specification: With Ceramic Based Crucible With Digital Thermocouple Heating Sensor Display Screen, Power - 440 V 3 Phase, Water Cooler - 35 Littre (In Built), Weight - 120 Kg, Dimensions - 36 X 30 X 45 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Refinery Machine 2Kg Charged Up To 6 Kg Per Day With Digital Display And Cooling System Should Have Excellent Thermal Insulation To Prevent Loss. Specification: Gold Refining Unit, Power Supply: 400 V / 3 Phase, Power: 0.3 Kw, Dimension In Mm: 1200 X 670 X 1120, Weight: 80 Kgs. To Have Low Running Costs, Fully Automated Process With Process Control And With Fumes Filter & Exhaust Filter And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Koras Refining Unit With Auto Stirrer Set Up With Acrylic Material Or Its Equivalent. , Supply And Installation Of Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed Specification: Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: High Pressure Hydraulic Die Cutting Machine From Hk Brand Or Its Equivalent. , Supply And Installation Of Mesh Chain Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of Box Chain Making Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of V-Chain Making Machine With Standard Accessories Specification: Motor: 0.50 Hp Pmdc Motor & Drive Speed Control Rpm 0 – 1500. 180 Wt. 1 Year All India Warranty. Table: Machine Cabinet Steel Mattel & Weight 49Kg. Electronic Panel: Dc Drive Full Electronic Panel• Sensor (Auto Cut)• Heater (37 Wt., Temperature 800O). Features: Automatic Machine For Venetian Chains, Variable Speed Controller, Forced Lubrications System With Oil Tank And Electronic Brake Sensor, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Best Indian Heavy Duty Machine/ Vekaria Brand Or Its Equivalent. , Supply And Installation Of 12 Pass Wire Drawing Machine With Full Set Of Standard Accessories Specification:Max. Wire Diameter (Guage/Mm) = 20/0.91 To 18/1.22.•Min. Wire Diameter (Guage/Mm) = 36/0.91 To 36/0.19.•Main Motor = 1.5 To 2 Hp.•Cooling Motor = 0.25 Hp.•Machine Weight =225 To 345 Kg. Heavy Duty Sturdy Metal Frame That Holds The Motor.•Transmission Drive.•Speed Control Drive.•Cooling Liquid Tank And Sprayer.•The Unwinding Reel.•The Motorized Winding Reel With Adjustable Clutch.•Steel Palermo For Longer Durability Of Machine. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent. , Supply And Installation Of Sheet And Wire Drawing Machine With Standard Accessories With Heavy Duty Motor Capacity And Auto Stopper Technology Specification: Wire & Sheet Rolling Mill For Gold & Silver • Roller Length 200 Mm X 100 Mm. • Heavy Duty Machine • Bronze Bushings • 5 Hp Electric Motor • Three Phase Power Supply • Hardened Ground Steel • Roller Mouth Openness: 20 Mm. • Weight 800 Kg, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent , Supply And Installation Of Laser Marking Machine Specification: Karat Mark: Laser Marker (20 / 30 W Power) Specification: Laser Power: 20 W-30 W, Laser Wavelength: 1064 Nm, Frequency Range: 20 - 120 Khz 1-600 Khz, Beam Diamter: 7+1 7 + 0.5, Format Supported: All Vector Files And Image Files (Bmp, Jpg, Gif, Tga, Png, Tif, Ai, Dxf, Dst, Plt), Scan Field: 100 X 100 Mm Scan Speed <<7000 Mm/S, Power Regulating Range: 10 -100 %, Cooling Method: Air Cooling, Operating Environment - 0° C - 40 ° C (Non -Condensing), Electricity Demand - 220 V (110 V)/50 Hz (60 Hz), Size & Weight - Around 24 X 17 X 15 In, Gross Weight Around 22 Kgs, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make /Model: Alpha Laser Marker (20/30 W Power) , Supply And Installation Of Xrf Machinemistral Sdd, Item Note: Xrf Karat Meter (Sdd) Stabilizer / Support Specification:Intended Use: Energy Dispersive X-Ray Measuring Instrument (Edxrf) To Determine Thin Coatings, Trace Elements And Alloys. Element Range Aluminium (13) To Uranium U (92) - Up To 24 Elements Simultaneously. Designs Bench Top Unit With Upward Opening Hood, Measurement Direction: From Bottom To Top, X-Ray Source, X-Ray Tube Micro Focus Tube With Tungsten Target And Beryllium Window, High Voltage Three Steps: 10 Kv, 30 Kv, 50 Kv, Aperture (Collimator) 4X Changeable: 00.2 Mm (7,9 Mils), Ø 0.6 Mm (23.6 Mils), Ø1 Mm (39.4 Mils). Primary Filter: 6X Changeable: Ni, Free, Al 1000 ?M (39.4 Mils). Al 500 ?M (19.7 Mils). Al 100 ?M (3.9 Mils), Mylar 100 Um (3.9Mils)Measurement Spot Depending On The Measuring Distance And On The Aperture In Use, The Actual Measurement Spot Size Is Shown In The Video Image. Smallest Measurement Spot Approx. 0.3 Mm (11.8 Mils) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Fisher Xrf Sdd Brand Or Its Equivalent. , Supply And Installation Of Assay Balance: 0.001 Mg Accuracy With Mettler Toledo Scale Je3002 G/M Gold Scale 3.200 With Digital Display. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232 C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Analytical Balance Machine With Digital Display With All Standard Accessories. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Precision Balance Machine With Digital Display With All Standard Accessories. Specification:Weighing Capacity: 62 Gresolution: 0.1 Mgcalibration: Externaldisplay Type: Clear Reverse Backlit Lcd Displaystandard Interface: Rs -232 Crepeatability: 0.1 Mgweighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of 50Gm, 100Gm, 200Gm, E2 Class Wire Weight With Display Attachment Item Note: 50Mg. E-2 Class Wire Weight With Nabl Calibration Certificate. Specification: Calibration Units With Stainless Steel Measuring Exact Weight Standards For Weighing Machines Block. Weights Intended To Ensure Traceability Between National Mass Standards (With Values Derived From The International Prototype Of The Kilogram) And Weights Of Class E2 And Lower. Class E1 Weights Or Weight Sets Shall Be Accompanied By A Calibration Certificate, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Tools And Equipment For Sampling Balling Pliers, Couplers, Scraping Tools, Tongs, Forceps, Rolling Mill Etc. For Complete Assay Set Up Please The Link As Provided Below, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Furnaces, Scrubbers, Parting Tray Etc. Item Note: For Hallmarking Full Setup Center Required. (3 Phase Power, Pollution Clearance Certificate Bis Approval Fee, And All Things) Specification: Annealing Furnace With 220V / Single Phase Along With Supporting Materials. Assay Supplies: Assay Laboratory Spare Parts And Consumables, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work For Complete Assay Set Up Please The Link As Provided Above Against Item No. 29 , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements..I)Cctv Cameras With Night Vision2 Megapixel Ip Cameras With Motorized Verifocal& Pixel Zoom ; Progressive Scan Cmos 1/2.8 Or 1/3Format; Focal Length 2.8 To 12Mm; Zoom Range – 4.2X Varifocal; Multiple Simultaneous Stream; Streams First Stream : Full Hd, 1~30Fps; 1280X720, 1~30 Fps; 704X576, 1-30Fps, Second Stream 704X576, 1~30Fps; 352X288 10~30Fps; Video Compression 32 Kbps ~ 16 Mbps, Support Cbr/Vbr; H.264 Version 3, High Profile Encoding And Motion Jpeg Format Support; 1920(W) X 1080(H) Or Higher Active Pixels; Built-In Ir With 2 Or More Epled; Sw Supported Digital Wdr ; Auto Blc; Sd Memory Slot Upto 32Gb Class 10; Minimum Illumination Icr Colour 0.1 Lux (F1.2 Agc On) B/W 0.001 Lux (F2 Agc On); Shutter Speed 1/25-1/10,000S ; Multiple Resolution 4Cif(704X576), Cif (352X288); 12Vdc / 24Vac / Ieee802.3Af Poe (Rj-45) Support; Supporting All Network Protocols (List The Supporting Protocols); 10/100 Base-T, I/O Audio Support, Audio Compression G.711; Multi-Level User Access With Password Protection; Ip Address Filtering; Https Encrypted Data Transmission; Ieee 802.1X Port-Based Authentication For Network Protection; Ip Address Filtering Https Encrypted Data Transmission; Operating Temperature -10 Deg C To +55Deg C,Onvif Compliant, 36 Months Comprehensive Warranty. Ce, Fcc, Emc & Rohs Certification; And Ul Certification For Core Adaptor Are Mandatory; Onvif Complaint Make: Cp-Plus/Cp-Unc-Tb21zl6s-Vmds27125/Panasonic/Pi-Spw 201Dl/Bosch/ Nti 50022-A3s. Integration Of Cctv System To The Central Server Unified Command Centre Solution Platform (Uccs) At District Police Headquarters Command Center(Dphcc) In Coordination With The Police Department / Designated Agencyand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of 32 Channel Network Video Recorder(Nvr) : Supply, Installation, Testing And Commissioning Of 32Ch Embedded 4K Nvr 4Sata Expandable Up To 40Tb, Audio Input & Output, Two Way Communication Supported, G7.11 Audio Format Support, 320Mb Recording Throughput, 16 Alarm Inputs & 4 Outputs, Rs485, Esata And Rs232 To Be Supported With Maximum 16 Users, Op. Temp -10 To 50 Deg. C, Ndaa Compliant, Ul/Ce/Fcc Certified, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Cp-Plus/Panasonic/Pi-Spw 201Dl/Bosch/ Octavision/Hikvision. , Supply And Installation Of Wallmounting Network Rack Supplyand Fixing Of 6 U Wallmounting Network Rack With Power Spike Including All Accessories Etc., Complete. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make:Hcl / Vall , Supply And Installation Of 8Port Poe Switch Supply & Fixing Of Small Business 8 Port Gigabit Poe Managed Switch, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. Make:Netgear/Dlink , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Lan Cable Cat -6 Utp Cable And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : D Link / Amp / Molex / Legrand / Krone, , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Hard Disk 8 Tb And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : Segate/ Sv-35/Toshiba. , Supply And Installation Of Air Conditioner A/C 2.0 Tonne A/C With Low Power Drive Module.Supply And Transportation Of Inverter Model Cool Type Split Ac Unitwith High Wall Mounted Single Split 100% Copper Indoor And Outdoor Condencing Unit Hermetically Sealed Compressor Suitable For Operation On 230V, 50Hz, 1Phase Ac Supply Capable Of Performing Heat Cool Dehumidifying Air Circulating And Filtering With Cooling And Condensing Units With 3.0 Mts Of Copper Piping, Insulation Kit And 4 Mts Of 4 Core Copper Flexible Chord (Voltage Range 160- 264 Volts) And Cordless Remote Control With Warranty Of Compressor For 5 Years And Comprehensive Maintenance For 2 Years2.0 / 1.8 Tr 5 Star Capable Of Delivering 21600 Btu/Hr And Above With Operating On Refrigerant R-32 / R-410 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Daikin / Toshibha / Carrier / Blue Star / Hitachi Or Equivalent , Supply And Installation Of Computers: Core-I7 10Th Gen Processor, 8Gb Ram, 1Tb Hdd, Windows 10 Pro. Specification: General :Wired Usb Keyboard & Optical Scroll Mouse 1 X Ps/2 Combo Port 2 X Usb 3.2 Gen 1 Ports 6 X Usb2.0 Ports 1 X Rj-45 Port 1 X Hdmi Port 1 X Vga Port 1 X Audio Port (Line Out/Line In/Mic In) 1 X Pci Express X16 Gen 3.0 Slot 1 X Pci Express X1 Gen 2.0 Slot 1 X Audio Port (Line Out/Line In/Mic In) 450W 19V/0.84A 80Mm X 310Mm X 395Mm 510Mm X 360Mm X 182Mm 12.5 Kg (Total Pc) Ce, Rohs Table Top 3 Years Warranty Cpu, Monitor, Keyboard & Mouse, User Manual, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Ups 10 Kva System (8 Kwatt ) Specification:Input Voltage 80 / 400 / 415 Vac; 3 Phase, Ninput Voltage Range ± 15%Input Frequency 50 / 60 Hzinput Frequency Range ± 10%Input Power Factor > 0,85Output Power Factor 0,8Output Voltage 380 / 400 / 415 Vac; 3 Phase, Noutput Frequency 50 Hz / 60 Hz (Selectable)Battery Type No Maintenance Batterybattery Unit 30Charge Voltage 405 Vdcbattery Charge Time 8 Hours To 90% Capacity After Deep Dischargebattery Test Automatic And Manuel Battery Test Systemover Load Capacity 100% ~ 125% Load 10 Minutes; 125% ~ 150% Load 1 Minute; > 150% Load On The Bypassdimension Wxhxd (Mm) 490 X 1200 X 680Weight ~ 240 Kg., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Generator (20Kva Dg Set) Specification: Power: 20 Kva (16Kw) Fuel Consumption (At 100% Load): 5.09 Ltrs/Hr Fuel Tank Capacity: 63 Ltrs Phase: 3 Phase Dry Weight (Kg): 720 Frequency: 50 Hz Engine: 2 Cylinder, In-Line 4 Stroke, Radiator Cooled Engine, Electrical Starter Motor With Soft Start Engagement Feature, Battery Charging Alternator. 1 X 12 V Dc Battery, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
40.
Power #10389362 AOC
Supply, Erection, Installation, Testing And Commissioning Of Control And Relay Panels Including Laying Of Cables From Switchyard To New Ecr Building Of Proposed 1X660 Mw Unit At Atps Chachai. , Supply Portion , Singlex Control, Relay (M1, M2) And Annunciations Panel For 220 Kv Transmission Lines As Per Schedule Of Requirements Clause No.25.07.00 , Singlex Control, Relay And Annunciations Panel For Bus Coupler And Transfer Tie Breaker For 220 Kv As Per Schedule Of Requirementsclause No.25.08.00 , Singlex Control, Relay And Annunciations Panel For 500 Mva Ict As Per Schedule Of Requirementsclause No.25.10.00 , Singlex Control, Relay And Annunciations Panel For 20 Mva Transformer(220 Kv Side) As Per Schedule Of Requirementsclause No.25.10.00 , Bus Bar Protection Panel With Dr For 16 No. 220 Kv Feeder Bay Along With Lbb Protection Including All Accessories Clause No. 25.13.00 ( Double Main & Transfer Bus Switchyard Scheme) , Singlex Control, Relay And Annunciations Panel For 20 Mva (33 Kv Side)As Per Schedule Of Requirementsclause No.25.11.00 , Singlex Control, Relay And Annunciations Panel For 33 Kv Feederas Per Schedule Of Requirementsclause No.25.11.00 , Singlex Control, Relay And Annunciations Panel For 33 Kv Solar Incoming Feeder As Per Schedule Of Requirementsclause No.25.11.00 , Singlex Control, Relay And Annunciations Panel For Bus Coupler For 33 Kv As Per Schedule Of Requirementsclause No.25.12.00 , Diagnostic Station For Numerical Relay & Bus Bar Relay With Disturbance Recording System Including Relay Software Alongwith Local Display Monitoring System Of The Substation As Per Schedule Of Requirementsclause No.25.09.00 , Gps System And Time Synchronization Facility For All Protection Relay And Energy Meter As Per Schedule Of Requirements Clause No. 27.00.00 , Supply Of Indoor Type 415/220 Volts Ac Power Distribution Switch Boards (Acdb) As Per Schedule Of Requirements Clause No.26.00.00 , Supply Of Indoor Type 220 Volts Dc Power Distribution Switch Boards (Dcdb) As Per Schedule Of Requirements Clause No. 26.00.01 , Trivector Meter- Energy Monitoring System With Pc System And Licensed Free Software As Per Schedule Of Requirements Clause No. 29.00.00 , Mandatory Spares As Per Clause No. 22.00.0 , Work Portion , Charges For Complete Erection, Testing & Commissioning Of Various Panels , 2 Core 2.5 Sq. Mm Cable Lying For 220 Kv Bays , 5 Core 4 Sq. Mm Cable Lying For 220 Kv Bays , 5 Core 2.5 Sq. Mm Cable Lying For 220 Kv Bays , 10 Core 2.5 Sq. Mm Cable Lying For 220 Kv Bays , 14 Core 2.5 Sq. Mm Cable Lying For 220 Kv Bays , 19 Core 2.5 Sq. Mm Cable Lying For 220 Kv Bays , 5 Core 2.5 Sq. Mm Cable Lying For 33 Kv Bays , 10 Core 2.5 Sq. Mm Cable Lying For 33 Kv Bays , Erection And Commissioning Of Acdb , Erection And Commissioning Of Dcdb , Earthing For The Panels Along With Earth Pits As Per Schedule Of Requirements Clause No. 09.07.00
Contract Date: Jun 16, 2026 Contract Value : 4.49 Crore
Government Departments No of Bidders 2
Madhya Pradesh View Result →
41.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
42.
Health and Family Welfare #10363172 Price Bid
Tender For Electrification Work In Phc Building At Khetasar Block Osian District Jodhpur; 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
43.
Power #10311585 Price Bid
Tender For Work Related To Replacement Of Control And Relay Panel Installed At 220Kv S/S Pratapgarh Under Electicity Transmission Division Pratapgarh., 1 Following work at 220KV S/S Pratapgarh 2 Shifting of new DPP Relay Panel from Store to Loading point by Crane/ Hydra & loading in Truck at 132 KV S/S Gadwara. The Crane charges, T&P and man power will be provided by contractor on his own cost. 3 Carriage of New 02No. DPP Relay Panel from 132 KV S/S Gadwara to 220KV S/S Pratapgarh (Approx Distance 20km.) The vehicle charges, T&P and man power will be provided by contractor on his own cost. 4 Unloading & Shifting of new DPP Relay Panel from unloading point to site by Crane/ Hydra at 220 KV S/S Pratapgarh The Crane charges, T&P and man power will be provided by contractor on his own cost. 5 Dismentalling of old DPP Relay Panel (Make Siemens) Installed in Control room by opening of cable connections, earthing flats, nuts, bolts etc. including safe disconnection of TBC scheme and cable loop panel to panel cable connection etc. & making of new loop connection (temporary) for other helthyness of running control panels as required. the work also includes identification of the control cables by providing suitable ferrules etc. for later use and safe shifting of the panels from control room to store Place/site at sub-station. 6 Insallation of new DPP Relay Panel (Make Nelumbo & Sifang) in control room after shifting from storage place, its grouting & earthing and termination of control cables in control and relay panel as per cable schedule including providing & fixing of cable gland of appropriate sizes and ferrules etc. with all other associated works as per technical specification including safe reconnection of TBC scheme and Panel to panel cables connection etc. The work also includes control cables connection as required between control panels for looping. The commmissiong of the realy panle shall be done jointly with T&C wing including troubleshooting as needed/necessary. Also inter connection diagram as per new Relay panel shall be submitted and got approved by the concerned supervsing engineer/incharge before start of work. after completaion of work shedule shall be provided as executed mentioning cable Tag, TB No. & ferrules for relay panel on A4 Size 100 gsm clear print. 7 Laying of following Size control cable in place of running jointing cable wetween Realay Panel to Circuit Braker & CT Juction Box in switchyard as per drawing with proper tagging. Ferruling and dressing, binding with clamp/cable tie on cable rack in tunnel and trench. The cable shall be passing through cable hall cable rack & tunnels rack and trench. The work also include opening of trench cover and re-fixing them from trench after completion of work satisfactorily. 8 6 core X 2.5 Sq. mm 9 4 core X 2.5 Sq. mm 10 Dismentalling and removing of following size old & unused/Dameged/defective/burst etc. Control cable from different cable rack in tunnel & trench. The work includes opening of its binding, collecting, shifting to site storage Place along with opening of trench cover and re-covering after completion of work satisfactorily. 11 6 core X 2.5 Sq. mm 12 4 core X 2.5 Sq. mm 13 Earthing of the New DPP Relay Panel with MS flat of size 50x6 mm. (MS flat will be provided by Department free of cost) with riser already connecting with epuipment as per standard. 14 work of commissioning, configuration and testing of New DPP Relay Panel (Make Nelmbo, Sifang) Testing must necessarily be carried out with the help of electronic secondary relay testing kit. All the requiredtests releted to above distance protection relay should be done axactly in accordance with the electrical norms and standard as per the guidance of T&C wing. 15 With GST
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
44.
Health and Family Welfare #10276803 Price Bid
Tender For Electrification Work At Construction Of Chc Building At Jhinjhiyali District Jaisalmer - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 20 mm 13 25 mm 14 32 mm 15 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 16 1 x 1.5 sq.mm 17 2 x 2.5 sq. mm. + 1x1.5sqmm 18 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 19 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 20 1 x 4.0 sq.mm 21 4 x 6.0 sq.mm 22 4 x 10.0 sq.mm 23 Providing & Fixing of ISI marked surface type buzzer (IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 24 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25 75 mm dia 26 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 27 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 5 step fan regulator 2 Module 360 dgree rotating 29 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 30 Blanking plate 31 25 Amp. 2 Module Motor Starter with on / off Push button 32 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 33 25 Amp. 2 Module Socket 34 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 36 Up to 380 mm size 37 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 38 3 pair 39 5 pair 40 50 pair 41 20 pair 42 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 43 20 Pairs 44 50 Pairs 45 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 46 1.2 mm thickM. S. Sheet boxes 47 175mm x 100mm x 60mm 48 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 49 3.0 mm thick 50 Providing & Fixing of flush typenon modular single line telephone jackmade out fromindustrial grade Polycarbonate or fire resistant ABS material, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Cat 6, Un-sheilded Information Outlet 54 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Single Aperture 56 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 Single pole MCB (With B/C curve tripping Characteristics) 58 6 A to 32 A rating 59 Triple pole MCB(With B/C curve trippingCharacteristics) 60 6 A to 32 A rating 61 50/63 A rating 62 Four pole MCB (With B/C curve tripping Characteristics) 63 6 A to 32 A rating 64 50/63 A rating 65 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 66 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 67 6Way(Incomer 8,Sub Incomer2+2+2) 68 8Way(Incomer 8,Sub Incomer2+2+2) 69 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 Two pole 100/300mA sensitivity 71 63 A rating 72 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 73 Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box 74 6 Way 75 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 76 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 77 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 78 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 79 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 80 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 81 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 17.2 mm thick and 3 Mtr. Long 83 Plate Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 25mm x 3mm copper strip 86 25mm x 3mm G.I. ( Hot Dipped) Strip 87 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 89 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 90 300 mm sweep(900/1400 RPM) 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 Wall mounting type with Adjustable Vertical Angle 95 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 97 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 98 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 99 Surface Moutning 100 Minimum lumen output 3600 lm 101 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 102 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 103 Surface Mounting (with extruded alumn. Housing ) 104 Minimum lumen output 1950 lm 105 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 106 6.0 Sq. mm 107 4 core 108 10.0 Sq. mm 109 4 core 110 16.0 Sq. mm 111 4 core 112 25.0 Sq. mm 113 3.5 core 114 50.0 Sq. mm 115 3.5 core 116 70.0 Sq. mm 117 3.5 core 118 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 4 x 6.0 sq.mm 120 4 x 10.0 sq.mm 121 4 x 16.0 sq.mm 122 3.5 x 70.0 sq.mm 123 3.5 x 50.0 sq.mm 124 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 125 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 126 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 127 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 128 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 129 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 130 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 131 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 132 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 133 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 134 Electrolytic grade Aluminium bus bar 6010 grade 135 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 Three phase Ammeterwith Inbuilt Selector Switch 137 Three phase Voltmeter with Inbuilt Selector Switch 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio upto 150/5, Burden 5 VA 141 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 142 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 143 Red/yellow/Green colour 144 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 146 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 148 Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phasesensing compensationpower factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 149 6 to 8 stage 150 Providing & Fixing of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 151 up to 6 KVAR 152 10 KVAR 153 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 154 3 pole MCCB With Thermal Magnetic release 155 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 156 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 157 4 pole MCCB With Thermal Magnetic release 158 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 159 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 160 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 161 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 162 LED Street Light fixture with Minimum lumen output 3700 lm 163 LED Street Light fixture with Minimum lumen output 8700 lm 164 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 165 SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be ofcarbon + S.S.The stator body of single phase pumpshall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 166 1.5 HP, 1-Ø, (18 -26) Mtr, (126 - 78) LPM 167 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 168 B class 50mm dia 169 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 170 For Three phase Submersible / Mono block pump 171 3.0 HP to 5.0 HP ( Star / Delta starter ) 172 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 173 6.0 Sq.mm 3 core flat / Round 174 Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 175 150mm x 50mm x 1.6mm 176 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 177 50mm x 50mm x 6mm 178 35mm x 35mm x 5mm 179 Providing & Fixing ofCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 10 AMP 181 32 AMP 182 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Open execution type 184 125 A 185 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 186 Poles with Octagonal Cross Section 187 7 Mtr. 188 Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 189 160 mm X 225 mm X 100 mm 190 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 191 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 192 1/2 Module 193 3 Module 194 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 1-2 Module 196 3 Module 197 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 15 Ltr. 199 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 Single arm overhang 201 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I 202 A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . 203 B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled 204 C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. 205 D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 206 E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA. 207 F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 208 G) Servicing Contract of DG Set from OEMs Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. 209 H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. 210 I) DG set will be offered for Inspection and Testing at Manufacturers Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 211 50 KVA at 0.8 pf 415V 50Hz 3-ǿ 212 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 50 to 82.5 KVA 214 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 215 8 SWG copper Wire 216 Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length)includingcutting,welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect.(Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 217 125 mm dia 218 P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 219 Supply, installation, testing & commissioning of following size & Material air termination rods confirming to IEC/EN 62561 with suitable OEM recommendedmounting arrangement on parapet wall all as per standard , complete as required. the test report accredited by third party accreditation body like VDE/ ILAC/ DAkkS/ UL/ NABL is to be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 220 1500 mm long, 10 mm Dia. Aluminium / AlMgSi 221 Supply & Fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 10 / 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1, tested to carry from 100KA (10/350μs) lightning current the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 222 Supply and Fixing of stainless steel clamp for holding 8mm dia. conductor on Parapet Wall / Side Fl 20 mm, Height- 20 mm & Complied as per Standard EN 62561-4. With accessories SS Screw and Gitty etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 223 Supply & LayingofAluminum / SS / AlMgSi Round Conductor confirming to IEC/EN 62561 etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. ( Supporting Clamps to be paid Extra )All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 224 8 mm Dia. Aluminium conductor 225 Supply and Fixing of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor with25 mm x 6 mm GI strip etc. as required. the test report accredited by third party accreditation body likeVDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 226 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 227 24 Ports 228 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 230 1 Mtr 231 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 232 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 233 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 234 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 235 1.5 TR ISEER not less then 3.8 236 2.0 TR ISEER not less then 3.8 237 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 238 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 4 kVA 240 5 kVA 241 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 242 25 mm 243 SITC of Interconnecting refrigerantcopper pipe forsplit/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizesas per OEM requirement & specifications including class O Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 244 Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existingsurface or recessed PVC/ MS conduit/casing capping/ Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 245 Armoured 246 4 core x 2.5 Sq.mm 247 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 249 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 250 4 kg 251 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 252 Capacity 4.5 Kg.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
45.
Health and Family Welfare #10187107 Price Bid
Tender For Electrification Work In Phc Building At Moriya District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
46.
Health and Family Welfare #10187103 Price Bid
Tender For Electrification Work In Phc Building At Bhudkiya District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
47.
Health and Family Welfare #10187085 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Manihari Block Pali District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
48.
Health and Family Welfare #10187079 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Sadri Block Desuri District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
49.
Health and Family Welfare #10187077 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Takhatgarh Block Sumerpur District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
50.
Health and Family Welfare #10187074 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Dhawa, Block Dhawa District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
TenderDetail
Loading tenders