View Bid Results For Tin Ducts Tenders

We found 103 Bid Results related to tin ducts tenders. You can find Contractor details who won tin ducts tenders along with contract details in Bid awards announcements section.

Filters
Stage
46
32
25
Tender Publishing Platform
11
92
State / UT
17
29
25
10
8
4
4
4
4
4
4
1
1
1
1
1
1
1
Contract Value
58
8
23
14
Publish Date
0
0
0
0
0
Sector
15
18
17
14
12
12
9
9
2
2
2
2
1
1
1
1
Ownership
5
59
17
15
11
1
Within keyword
Active filters:
Showing 1–3 of 103 tenders matching your filters
1.
Tourism #11266721 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Jul 03, 2026 Contract Value : 5.42 Crore
Government Departments No of Bidders 2
3.
Housing Urban and Rular Development #11229363 AOC
Misc. Repairs And Other Civil Works Of Tiles, Doors, Windows,Wooden Flooring, Shed And Internal And External Painting In C.M. Bunglow Civil Line Nagpur.(Only For Society).-= 1 Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand 2 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 3 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete. 4 Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 1190 to 1202 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete. a) Flooring 5 Providing and laying Vitrified MATT finishhaving decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmakeshadeandpatternfor flooringinrequiredpositionlaidonabedofbondingchemicalfillingjointscuringand cleaning etc .complete. 6 Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 7 Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 8 Providing and fixingTable top white wash basin of size 120x635x405mm rubber plugs and brass chain, withpillar cock, C.P.Angular stop cock long thread, continentalincluding S.S. bottle trap of approved make havingnecessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. 9 ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete. 10 Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension ?63.50 x 38.10 x 1.02 mm at weight 0.547 kg/Rmt. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 kg/Rmt. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. And handle section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. and top section 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box 11 Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to give the appearance of tiles of 30 cm x 30 cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete. With Crushed Sand. 12 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 14 Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etccomplete 15 Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete.b) Granite 16 Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. 17 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. 18 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc.as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete.Spec. No. : As directed by Engineer-in-charge. 19 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (a) 2.00 mm thick. 20 Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. 21 Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. 22 Removing W.C. Pan including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the service-able materials as and where directed includingthrowing the unserviceable materials out side etc. complete. 23 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 24 Providing and fixing 10 cm PVC nahani trap with grating etc. complete. 25 Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. 26 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 27 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 28 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 29 Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 30 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 31 Providing and fixing C.P. BIB cock with wall flange jaquar or equivalent make continental (CAT.NO. CON-047) including necessary sockets/ union nut etc. complete. 32 Providing and fixing C.P. Angular stop clock with wall flange Jaquar make or equivalentcontinental (CAT.NO. CON-059) including necessary sockets/union nut etc. complete. 33 Providing and fixing C.P. pillar cock long neck with aerator jaquar or equivalent make continental (CAT.NO. CON -021) including necessary sockets/union nut etc. complete. 34 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 35 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 36 Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. 37 Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets & necessary fittings and tested as per municipal requirement etc. complete. 38 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres 39 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 40 Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover. 41 Providing & constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover etc. complete. 42 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange jaquar or equivalent ?make continental (CAT.NO. CON-273 UPR) including necessary sockets/union nut etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 45 Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) 46 Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. 5 km leadloading unloading 47 Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated materialetc. complete. 48 Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 kg) 49 Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 kg) 50 Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kg/sq.m of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaningetc. complete. (using 100% crushed sand) 51 Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards,screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 52 Providing and fixing Shutter to wall Cupboard consisting of Teak Wood styles and Rails 25 mm thick and 75 mm wide with panel insert of 12 mm thick particle Board with one approved coloured Laminated Face on one side 1.5 mm thick, bonded with Phenol Formaldehyde Synthetic Resin including Lipping Beading. Iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). 53 Providing and fixing valley gutter of 22 B.W.G. (0.8 mm) plain galvanised iron sheets 90 cm wide with teak wood planking 20 mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). 54 Providing and fixing C.P. 2 Way BIB cock with wall flange of approvedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge. 55 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) 56 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 57 Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. 58 Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete 59 Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessaryscrew, making proper adjustment for smoothoperation etc. complete as per sample approved by Engineer in-chareg. 60 ProvidingHydrulic door closer .... 61 ProvidingSuper Jet Spry with flange 2 in 1 faucet 1.50 mtr long. 62 Providing Skilled plumber with tools as per direction of Engineer Incharge. 63 Providing skilled carpentor with tools as per direction of Engineer Incharge 64 Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface and including scraping etc. complete. 65 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 66 Providing and applying single coats ofexterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete. 67 Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete 68 Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 69 Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. 70 Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete 71 Providing curtain rod dropping with channel MAC brand of superiar quaility including all required material labour etc complete. as directed by engineer incharge......... 72 Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and maketo door shutter including removing existing the same inoriginal position making prope radjustment for smooth operation etc. complete as per sample approved by Engineer incharge. 73 Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and maketo door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. 74 Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and maketo door/window shutter including removing existing the same inoriginal position making proper adjustment for smooth operationetc.complete as per sample approved by Engineer in-charge. 75 ProvidingHandle 150 mm Chromium plated (Rounded shape). 76 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. 77 Providing and injecting epoxy grout including structuring of crack in the body of slab girder by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete. 78 Providing & fixing Decorative wall paper superior quality including adhesive to fix at wall etc complete. as directed by engineer incharge......... 79 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 80 Providing & fixing Mica laminate as per ISI 0.1 mm thick etc complete...... 81 Providing & fixing 19 mm plywood 710 bwp full red core with report etc complete...... 82 Providing & fixing 12 mm plywood 710 bwp full red core with report etc complete...... 83 Providing & fixing teak wood batterns 50x25 mm etc complete...... 84 Providing & fixing plain glass 6 mmetc complete...... 85 Providing & fixing teak wood batterns 70x45 mm etc complete...... 86 Providing & fixing door stopper etc complete...... 87 Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. 88 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 89 Providing and Laying wearing laminate wooden or eqiuvalent flooring 8 mm thick in attractive strips for conference hall. 90 Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 kg/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 91 Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. 92 Providing and Fixing Vertical Blinds of approved Make and shade of 100mm regular fabric with powder coated aluminium channel with telting PVC chain & bottom weight plate with allnecessaryfixturesandfittingetc.complete.(SampletobefinalbyEngineerIn-charge prior execution of work) 93 Providing and applying French polish for required finish on previously polished wood including knotting, preparing the surfaces, scaffolding etc. complete as directed 94 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. 95 Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 96 Providing and fixing C.P. sink cock with raised J shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete. 97 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete. 98 Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. 99 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 100 BASIC TEST OF CEMENT :-Standerd Consistancy Fineness, Specific Graviti, Setting Time (Initial & final, Compressive Strength, Soundness. 101 BASIC TEST OF BRICK :-Water Absorption, (Set of 5 Brick), Comoressive Strength (Set of 5 Blocks), Efflorescence (Set of 5 Bricks) 102 CERAMIC TILES/ VITRIFIED TILES :- Water Absorption, Modules of Rapture (Set of 6 Tiles) 103 BASIC TEST OF C. C. TILES. :-Flexural test(Set of 6 tiles) Water Absorption,(Set of 6 tiles) Resistance to wear(Set of 6 tiles). 104 BASIC TEST OF Fine Aggregate Fineness Modulus (Sieve Analysis) silt and cley content..... 105 BASIC TEST OF Concrete Paving Block :- Compressive strength, Water Absorption, (Set of 8 Blocks ) 106 BASIC TEST OF STONE / RUBBLE/ Crushing Value/Compressive strengh, Water 107 Providing royalty charges against royalty paid by the contractor to the Revenue department for supply of different construction materials for whichroyalty is necessary.(Royalty charges will be paid to contractor after sumbitting valid documents of revenue authority)Royalty for naturalSand (Royalty + Surcharges 2% & Distt. mineral foundation cess 10%)
Contract Date: Jun 04, 2026 Contract Value : 15.18 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
4.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
5.
Public Administrative Department #10761690 Price Bid
Palika Kshetra Mein Ward No.01 Se 25 Tak Vibhinn Sthano Par Octagonal Pole Evam Led Light Lagane Ka Kary , Supply And Erection Of M.S. Galvanized Octagonal Pole ( As Per Bsen 40-3-3:2003 /Bsen 10025/Is 2062 Is:875 Part-1 – 2015/ For Ms Plate For Base Flange )Of Following Length And Dimension As Per Table P-01 With Base Plate On The Cement Concrete Foundation Of M- 20 Grade (1:1.5:3) As Per Is 456/Is 2911. With The Help Of Anchor Bolts Of Grade 6.8 (Is: 1367 P Iii ). The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Octagonal Ms Poles Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. (See Table P -01 For Specs.) 7 Mtr. , Supply, Erection And Fixing Of Hot Dipped Galvanised M.S. Overhang (48.3 X 3.25 Mm) With Cap (400 X 88.9 / 114.3 X 3.25 Mm) Over The Existing Poles. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Single Arm Overhang , Supply, Erection And Fixing Of Hot Dipped Galvanised M.S. Overhang (48.3 X 3.25 Mm) With Cap (400 X 88.9 / 114.3 X 3.25 Mm) Over The Existing Poles. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Double Arm Overhang , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured/ Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points (A), (B), (C), Mentioned Below:- (A) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I (B) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 (Part 0 To 64 ) For Testing Procedures. (C) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr. Armoured Cable 16.0 Sq. Mm 2 Core , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Unarmoured/ Armoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points (A), (B), (C), Mentioned Below:- (A) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I (B) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 (Part 0 To 64 ) For Testing Procedures. (C) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr. Armoured Cable 16.0 Sq. Mm 3.5 Core , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C ,Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 3 X 4 Sq. Mm. , Sitc Of Chemical Gel Earthing System Of Dual Pipe Technology Made Of With B Class G I Pipe As Per Is 1239 ( Part-1):2004 Of Medium Duty Of Following Sizes As Per Points Mentioned (A), (B), [C), (D), (E) Below :- (A) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 35- 40 Ka For Withstanding 1 Second . (B) To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043- 1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts (C) Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Self Certificate For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Gi Pipe 3000 Mm Long, 50 / 25Mm, Terminal 40Mm X 6 Mm Gi Strip , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass (For Cu Strip) / Gi (For Gi Strip) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 25Mm X 5Mm Copper Strip , Providing & Fixing Of Ik07 Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Lm6/ Adc12 Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc/Toughened Glass Cover (Uv Stablzation Report Submitted For Uv Cover ) And Secondary Lens On Each Led & Should Be Smd Type . The System Level Luminaire Efficacy >=120 Lm/ Wt With High Power Leds Is To Be Used And Potted Driver Must Be Potted & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85% ,Thd(I) <10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current <1000Ma Shown In Lm79 Report. The Luminaire Shall Be Bis Certified And T.C. Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened ,Color Rendering Index >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr. Led Street Light Fixture 90 Watt , Supply And Installation Of Spike Of M.S. Rod 20Mm Dia 3.0Mtr. Long For Earthing Of (Tower/Pole) Drive Into Earth By Mechanical Means Sturcture Connection The Spike With Cross Arm Top Hamper Pcc Pole, Lattics Tower To Earth Etc. Complete As Per Technical Specification Of Discom. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing, Lowering, Laying & Jointing Mdpe/ Hdpe Pipes (Class-Pe 80) Pn 12.5 Composite Pipes For Extra Length For House Service Connections As Per Drawing And Specifications Complete Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. With Hdpe Pipe 32 Mm Dia Service Pipe , Providing & Fixing Of Iso Certified Company Made Tp&N 415 V Side Handle Operated Double Break Fuse Switch Unit In Sheet Steel Enclosure As Per Pwd Specification For Electrical Works Conforming To Is/Lec 60947-3 : 1999 (W/O Hbc Fuses) Including Making Connections With Suitable Lugs, Testing Etc. As Required. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr. 63 A Rating , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work , Refer Annexure A Attached With This Bsr . 3 Pole Power Contactors With Following Ac 3 Rating 80 Amp , Providing & Fixing Of Powder Coated Crca Sheet On Existing Angle Iron Frame By Means Of Nuts And Bolts And Making Holes , Etc. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 2.5 Mm Thick , Supplying And Fixing Of Aluminium (Iec 60105 Iso 209-1,2) / Copper (Iec 60028) Bus Bar As Per Pwd Specification For Electrical Works, By Means Of Smc / Dmc Type Insulator, High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Electrolytic Grade (Cu-Etp) Tin Coated Annealed Copper Bus Bars Iacs 100% Grade , P &F In Position Frame Made Out Of M.S. Angle (Riveted Or Welded) Finished With Two Coat Of Red Oxide And Enamel Paint Including Cutting, Welding, Holes Etc. Of Following Sizes As Required. 40Mm X 40Mm X 5Mm , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (B/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/Sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Four Pole Mcb 80 A Rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
6.
Educational and Research Institute #10758945 Price Bid
The Items Rate Contract For Supply Of Civil Works At Nit Silchar Exclusive Of All Taxes And Levies, Including Carrying Charges. Civil Material Rate Contract , Civil Building & Road Items , Gi Pipe 80Mm (Tata / Neozone Medium) , Gi Pipe 65Mm (Tata / Neozone Medium) , Gi Pipe 50Mm (Tata / Neozone Medium) , Gi Pipe 40Mm (Tata / Neozone Medium) , Gi Pipe 32Mm (Tata / Neozone Medium) , Gi Pipe 25Mm (Tata / Neozone Medium) , Gi Pipe 20Mm (Tata / Neozone Medium) , Gi Pipe 15Mm (Tata / Neozone Medium) , Gi Tee 15Mm , Gi Tee 20Mm , Gi Tee 25Mm , Gi Tee 32Mm , Gi Tee 40Mm , Gi Tee 50Mm , Gi Tee 65Mm , Gi Tee 80Mm , Gi Bend 15Mm , Gi Bend 20Mm , Gi Bend 25Mm , Gi Bend 32Mm , Gi Bend 40Mm , Gi Bend 50Mm , Gi Bend 65Mm , Gi Bend 80Mm , Gi Elbow 15Mm , Gi Elbow 20Mm , Gi Elbow 25Mm , Gi Elbow 32Mm , Gi Elbow 40Mm , Gi Elbow 50Mm , Gi Elbow 65Mm , Gi Elbow 80Mm , Gi Union Socket 15Mm , Gi Union Socket 20Mm , Gi Union Socket 25Mm , Gi Union Socket 32Mm , Gi Union Socket 40Mm , Gi Union Socket 50Mm , Gi Union Socket 65Mm , Gi Union Socket 80Mm , Gi Socket15mm , Gi Socket20mm , Gi Socket25mm , Gi Socket32mm , Gi Socket40mm , Gi Socket50mm , Gi Socket65mm , Gi Socket80mm , Gi Reducing Elbow 15Mm X 20Mm , Gi Reducing Elbow 15Mm X 25Mm , Gi Reducing Elbow 15Mm X 32Mm , Gi Reducing Elbow 15Mm X 40Mm , Gi Reducing Elbow 15Mm X 50Mm , Gi Reducing Elbow 20Mm X 25Mm , Gi Reducing Elbow 20Mm X 32Mm , Gi Reducing Elbow 20Mm X 40Mm , Gi Reducing Elbow 20Mm X 50Mm , Gi Reducing Elbow 25Mm X 32Mm , Gi Reducing Elbow 25Mm X 40Mm , Gi Reducing Elbow 25Mm X 50Mm , Gi Reducing Elbow 32Mm X 40Mm , Gi Reducing Elbow 32Mm X 50Mm , Gi Reducing Elbow 32Mm X 65Mm , Gi Reducing Elbow 40Mm X 65Mm , Gi Reducing Elbow 40Mm X 80Mm , Gi Reducing Elbow 65Mm X 80Mm , Gi Reducing Tee 15Mm X 20Mm , Gi Reducing Tee 15Mm X 25Mm , Gi Reducing Tee 15Mm X 32Mm , Gi Reducing Tee 15Mm X 40Mm , Gi Reducing Tee 15Mm X 50Mm , Gi Reducing Tee 20Mm X 25Mm , Gi Reducing Tee 20Mm X 32Mm , Gi Reducing Tee 20Mm X 40Mm , Gi Reducing Tee 20Mm X 50Mm , Gi Reducing Tee 25Mm X 32Mm , Gi Reducing Tee 25Mm X 40Mm , Gi Reducing Tee 25Mm X 50Mm , Gi Reducing Tee 40Mm X 32Mm , Gi Reducing Tee 40Mm X 65Mm , Gi Reducing Tee 40Mm X 80Mm , Gi Reducing Tee 50Mm X 32Mm , Gi Reducing Tee 65Mm X 80Mm , Gi Reducing Socket 15Mm X 20Mm , Gi Reducing Socket 15Mm X 25Mm , Gi Reducing Socket 15Mm X 32Mm , Gi Reducing Socket 15Mm X 40Mm , Gi Reducing Socket 15Mm X 50Mm , Gi Reducing Socket 20Mm X 25Mm , Gi Reducing Socket 20Mm X 32Mm , Gi Reducing Socket 20Mm X 40Mm , Gi Reducing Socket 20Mm X 50Mm , Gi Reducing Socket 25Mm X 32Mm , Gi Reducing Socket 25Mm X 40Mm , Gi Reducing Socket 25Mm X 50Mm , Gi Reducing Socket 40Mm X 32Mm , Gi Reducing Socket 40Mm X 65Mm , Gi Reducing Socket 40Mm X 80Mm , Gi Reducing Socket 65Mm X 80Mm , Gi Nipple 15Mm X 32Mm , Gi Nipple 15Mm X 50Mm , Gi Nipple 15Mm X 65Mm , Gi Nipple 15Mm X 80Mm , Gi Nipple 15Mm X 100Mm , Gi Nipple 15Mm X 150Mm , Gi Nipple 15Mm X 200Mm , Gi Nipple 15Mm X 225Mm , Gi Nipple 20Mm X 32Mm , Gi Nipple 20Mm X 50Mm , Gi Nipple 20Mm X 65Mm , Gi Nipple 20Mm X 80Mm , Gi Nipple 20Mm X 100Mm , Gi Nipple 20Mm X 150Mm , Gi Nipple 20Mm X 225Mm , Gi Nipple 25Mm X 32Mm , Gi Nipple 25Mm X 50Mm , Gi Nipple 25Mm X 65Mm , Gi Nipple 25Mm X 80Mm , Gi Nipple 25Mm X 100Mm , Gi Nipple 25Mm X 150Mm , Gi Nipple 25Mm X 225Mm , Gi Nipple 25Mm X 300Mm , Gi Nipple 32Mm X 100Mm , Gi Nipple 32Mm X 150Mm , Gi Nipple 40Mm X 50Mm , Gi Nipple 40Mm X 65Mm , Gi Nipple 40Mm X 80Mm , Gi Nipple 40Mm X 100Mm , Gi Nipple 40Mm X 150Mm , Gi Nipple 40Mm X 225Mm , Gi Nipple 40Mm X 300Mm , Gi Nipple 50Mm X 50Mm , Gi Nipple 50Mm X 65Mm , Gi Nipple 50Mm X 80Mm , Gi Nipple 50Mm X 100Mm , Gi Nipple 50Mm X 150Mm , Gi Nipple 50Mm X 225Mm , Gi Nipple 50Mm X 300Mm , Gi Nipple 65Mm X 50Mm , Gi Nipple 65Mm X 65Mm , Gi Nipple 65Mm X 80Mm , Gi Nipple 65Mm X 100Mm , Gi Nipple 65Mm X 150Mm , Gi Nipple 65Mm X 225Mm , Gi Nipple 65Mm X 300Mm , Gi Plug 15Mm , Gi Plug 20Mm , Gi Plug 25Mm , Gi Plug 32Mm , Gi Plug 40Mm , Gi Plug 50Mm , Gi Plug 65Mm , Gi Plug 80Mm , Brass Bib Cock Royal Make , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore , Brass Bib Cock Jaguar Make , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore , Brass Stop Cock Royal Make , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore , Brass Stop Cock Jaguar Make , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore , Gun Metal Gate Valve With C.I. Wheel (Zest / Zoloto Make) , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore. , (C) 25Mm Nominal Bore , (D) 32Mm Nominal Bore , (E) 40 Mm Nominal Bore , (F) 50 Mm Nominal Bore , (G) 65 Mm Nominal Bore , (H) 80 Mm Nominal Bore , Ball Valve (Brass) (Zest / Zoloto Make) , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore , (C) 25 Mm Nominal Bore , (D) 32Mm Nominal Bore , (E) 40 Mm Nominal Bore , Gun Metal Non- Return Valve (Zest Make) , (A) 25 Mm Nominal Bore , (I) Horizontal , (Ii) Vertical , (B) 32 Mm Nominal Bore , (I) Horizontal , (Ii) Vertical , (C) 40 Mm Nominal Bore , (I) Horizontal , (Ii) Vertical , (D) 50 Mm Nominal Bore , (I) Horizontal , (Ii) Vertical , (E) 65 Mm Nominal Bore , (I) Horizontal , (Ii) Vertical , (F) 80 Mm Nominal Bore , (I) Horizontal , (Ii) Vertical , Brass Ferrule With C.I. Mouth Cover , (A) 15 Mm Nominal Bore , (B) 20 Mm Nominal Bore , (C) 25 Mm Nominal Bore , Uplasticised Pvc Connection Pipe With Brass Unions , (A) 30 Cm Length , (I) 15 Mm Nominal Bore , (Ii) 20 Mm Nominal Bore , (B) 45 Cm Length , (I) 15 Mm Nominal Bore , (Ii) 20 Mm Nominal Bore , (C) 60 Cm Length , (I) 15 Mm Nominal Bore , (Ii) 20 Mm Nominal Bore , Gyser Connection Pipe , Gland Packing (8Mm) , Gland Packing (12Mm) , Greese , Plastic Bib Cock 1/2 (Prayag Make) , Plastic Bib Cock 3/4 (Prayag Make) , Push Bib Cock Female Tread , Push Bib Cock With Reducer , Cp Pillar Cock Royal Make , Cp Pillar Cock Jaguar Make , Cp Shower Royal Make , Cp Shower Jaguar Make , Cp Spray Shower Without Arms 15Mm Dia Royal Make , Cp Spray Shower Without Arms 15Mm Dia Jaguar Make , Cp Shower With Bend 15Mm Dia Royal Make , Cp Shower With Bend 15Mm Dia Jaguar Make , Telephonic Chrome Plated (C.P.) Shower With Hook W/O Tube Sonamake , Telephonic Chrome Plated (C.P.) Shower With 1.5M Pvc Flexible Tube And Cp Hook(Light) Of Agmeco Make , Chrome Plated (C.P.)Basin Mixer - Jaguar / Marc Make , Basin Couplin (Big Size) , Urinal Pipe , Chrome Plated (C.P.)Wall Mixer - Jaguar / Marc Make , White Vitreous Water Closet Squatting Pan (Indian Type W.C Orissa Pattern) Of Size 580 X 440 Mm With 100 Mm Sci P Or S Trap - Parryware / Hindware Make , White Vitreous China Pedestal Type Water Closet (European Type W.C Pan 400Mm High ) Of Parryware/Hindware Make , White Vitreous China Flat Back Type Lippedfront Urinal Basin Of (455X360x267)Mm Of Parryware / Hindware , 5 Lits Capacity Cistern (Hindware / Parryware) , 10 Lits Capacity Cistern (Hindware / Parryware) , Cp Stop Cock (Jaquar Make) , Cp Angle Stop Cock (Jaquare Make) , Cp Bib Cock (Jaquare Make) , Cp Bib Cock 15Mm Big Size (Jaquar Make) , Plumber Zink , Basin Waste Pipe , Waste Coupling , Cp 3 In 1 Bib Cock (Sona Make) , Pvc Water Tank Syntex Make , (A) 2000 Lits Capacity , (B) 1000 Lits Capacity , (C) 500 Lits Capacity , Gi Tank Connection , (A) 80Mm , (B) 65Mm , (C) 50Mm , (D) 40Mm , (E) 32Mm , (F) 25Mm , M. Seal Plumber , White Cement , Mirror With Plastic Frame Of Size 500X400mm , 63Mm Pvc Pipe (Supreme / Prince) , 63Mm Pvc Bend (Supreme / Prince) , 63Mm Pvc Tee (Supreme / Prince) , 110Mm Pvc Pipe (Supreme / Prince) , 110Mm Pvc Bend (Supreme / Prince) , 110Mm Pvc Door Bend (Supreme / Prince) , 110Mm Pvc Tee (Supreme / Prince) , 110Mm Pvc Door Tee (Supreme / Prince) , 150Mm Pvc Pipe (Supreme / Prince) , 150Mm Pvc Bend (Supreme / Prince) , 150Mm Pvc Door Bend (Supreme / Prince) , 150Mm Pvc Tee (Supreme / Prince) , 150Mm Pvc Door Tee (Supreme / Prince) , 63Mm Pvc Coupler , 110Mm Pvc Coupler , 150Mm Pvc Coupler , Pvc Clip With Screws For Fixing 63Mm Pipe , Pvc Clip With Screws For Fixing 110Mm Pipe , Pvc Clip With Screws For Fixing 150Mm Pipe , Ci Plug , Ci15mm , Ci 20Mm , Ci 25Mm , Ci 40Mm , Ci 50Mm , Cp Royal Make Long Neck Bib Cock , Cp Jaquar Make Long Neck Bib Cock , Cp Royal Make Long Neck Pillar Cock , Cp Jaquar Make Long Neck Pillar Cock , Ci Sluice Valve 100Mm Heavy Quality , Blade For Tread Cutting 15Mm - 25Mm , Blade For Tread Cutting 32Mm -50Mm , 30Mm Flush Door Isi Make , 35Mm Flush Door Isi Make , 4Mm Thick Commercial Ply Board , 6Mm Thick Commercial Ply Board , 9Mm Thick Commercial Ply Board , 12Mm Thick Commercial Ply Board , 16Mm Thick Commercial Ply Board , 19Mm Thick Commercial Ply Board , 4Mm Thick Weather Proof Ply Board , 6Mm Thick Weather Proof Ply Board , 9Mm Thick Weather Proof Ply Board , 12Mm Thick Weather Proof Ply Board , 16Mm Thick Weather Proof Ply Board , 19Mm Thick Weather Proof Ply Board , 40Mm X 48Mm Wood Reinforced Pvc Door Chowkhats Fixed To The Columns / Stiffeners / Walls With Necessary Holdfast / Sleeves Etc , Polymer Reinforced Moulded Pvc Door Shutters Fixed To The Chowkath With Necessary Hinges, Screws, Bolts Etc , A) 24Mm Thick , B) 29Mm Thick , Opc Cement , (A) Star , (B) Dalmia , (C) Crown , (D) Topcem , Ppc Cement , (A) Star , (B) Dalmia , (C) Topcem , Ppc Cement - Star / Dalmia / Topcem (Size Of The Tin: 30Cm X 45Cm) , Coarse Sand (Size Of The Tin: 30Cm X 45Cm) , 20Mm Down Crusher Stone (Size Of The Tin: 30Cm X 45Cm) , 10Mm Down Crusher Stone (Size Of The Tin: 30Cm X 45Cm) , Coarse Sand (With Forest Royalty) , Coarse Sand (Without Forest Royalty) , 40Mm Down Crusher Stone (With Forest Royalty) , 40Mm Down Crusher Stone (Without Forest Royalty) , 20Mm Down Crusher Stone (With Forest Royalty) , 20Mm Down Crusher Stone (Without Forest Royalty) , 10Mm Down Crusher Stone (With Forest Royalty) , 10Mm Down Crusher Stone (Without Forest Royalty) , 6Mm Down Crusher Stone (With Forest Royalty) , 6Mm Down Crusher Stone (Without Forest Royalty) , Sand Gravel Including Forest Royalty , 1St Class Brick , 2Nd Class Brick , Brick For Soling , Reinforcement Tata / Sail , (A) 8Mm Dia , (B) 10Mm Dia , (C) 12Mm Dia , (D) 16Mm Dia , (E) 20Mm Dia , (F) 25Mm Dia , Binding Black Wire , Coconut Rope , Plastic Rope , Muli Bamboo , Bathua Bamboo , Bakal Bamboo , Glass Strip , (A) 25 Mm Wide , (I) 4 Mm Thick , (Ii) 6 Mm Thick , (B) 40 Mm Wide , (I) 4 Mm Thick , (Ii) 6 Mm Thick , (C) 50 Mm Wide , (I) 4 Mm Thick , (Ii) 6 Mm Thick , (D) 65 Mm Wide , (I) 4 Mm Thick , (Ii) 6 Mm Thick , 4Mm Thick Clear Glass , 4Mm Thick Floasted Glass , 5Mm Thick Clear Glass , 5Mm Thick Floasted Glass , 6Mm Thick Clear Glass , 6Mm Thick Colour Glass , Glass Putty Shalimar Brand , Glass Clip , Gypboard Ceiling Board 9.5Mm Thick , Gypboard Ceiling Board 12.5Mm Thick , Cgi Sheet Tata Shaktee 0.63Mm Thick , Cgi Sheet Ridging , (E) 0.63 Mm Thick , (I) 150 Mm Lapping , (Ii) 230 Mm Lapping , Galvanized J Or L Hook , 8Mm Dia To 16Mm Dia Nut Bolts , Bitumen Washer 25 Mm Dia X 3 Mm Thick , 1.6 Mm Thick Limpet Washer , Corrugated 1.20 Mm Thick Transparent Fibre Sheet Roofing , 1.2Mm Thick Transparent Fibre Sheet Ridging , (A) 1.20 Mm Thick - 150 Mm Lapping , (B) 1.20 Mm Thick - 300 Mm Lapping , Ms Square Bar (8Mm, 10Mm, 12Mm) , Ms Flat (20Mm X 4Mm, 20Mm X 5Mm, 25Mm X 4Mm, 25Mm X 5Mm, 25Mm X 6Mm, 40Mm X 4Mm, 40Mm X 5Mm, 40Mm X 6Mm, 50Mm X 4Mm, 50Mm X 5Mm, 50Mm X 6Mm) , Ms Angle(20X20x3, 25X25x3, 25X25x5, 31X31x3, 35X35x5, 37X37x3, 40X40x3, 40X40x5, 40X40x6, 50X50x5, 50X50x6, 60X60x6, 65X65x6, 75X75x6) , Cement Primer (Jonson / Nerolac / Berger / Asian) , White Distemper (Jonson / Nerolac / Berger / Asian) , Colour Distemper (Jonson / Nerolac / Berger / Asian) , Weather Coat (Jonson / Neolac / Berger / Asian) , Red Oxide Primer , Wood Primer , Synthetic Paint (Jonson / Nerolac / Berger / Asian) , Thineer , Paint Brass 25Mm , Paint Brass 50Mm , Paint Brass 75Mm , Paint Brass 100Mm , Electro Coloured Iron Fittings , A) Sliding Door Bolts , I) 300Mm X 16Mm , Ii) 250Mm X 16Mm , B) Tower Bolts , I) 300Mm X 10Mm , Ii) 250Mm X 10Mm , Iii) 200Mm X 10Mm , Iv) 150Mm X 10Mm , V) 100Mm X 10Mm , C) Cast Iron Stove Door Handles , I) 75Mm , Ii) 100Mm , Iii) 150Mm , D) Ms Door Handles , I) 75Mm , Ii) 100Mm , Iii) 150Mm , E) Ms Gate Shutter Hook & Eye , I) 75Mm , Ii) 100Mm , Iii) 150Mm , Iv) 250Mm , V) 300Mm , F) Ms Wire Hasp And Staples , I) 90Mm / 75Mm , Ii) 115Mm , Iii) 150Mm , G) Ms Butt Hinge , I) Heavy Type , I) 50Mm X 40Mm X 2.5Mm , Ii) 75Mm X 60Mm X 3.15 , Ii) Medium Type , I) 50Mm X 37Mm X 1.5Mm , Ii) 75Mm X 47Mm X 1.60Mm , Iii) 100Mm X 58Mm X 1.90Mm , Iii) Light Type , I) 50Mm X 30Mm X 0.90Mm , Ii) 75Mm X 40Mm X 1.12Mm , Iii) 100Mm X 50Mm X 1.25Mm , H) Ms Pariamentary Hinge , I) 75Mm ( 100Mm X20mm X2.24Mm ) , Ii) 100Mm (125Mm X 27Mm X 2.80Mm) , Ii) 125Mm (125Mm X 27Mm X 2.80Mm) , I) Ms Double Acting Spring Hinge , A) 100Mm , B) 125Mm , C) 150Mm , J) Ms Continuous Hinge , 35Mm X 1.00M , K) Ms Door Latches , I) 300Mm X 20Mm X 6Mm , Ii) 250Mm X 10Mm X 6Mm , L) Ms Mortice Night Latches , M) Ms Rim Latches , I)100Mm , Ii)125Mm , Iii) 150Mm , Anodised Aluminium Fittings , A) Sliding Door Bolts , I) 300Mm X 16Mm , Ii) 250Mm X 16Mm , B) Tower Bolts , I) 300Mm X 12Mm , Ii) 250Mm X 12Mm , Iii) 200Mm X 12Mm , Iv) 150Mm X 10Mm , V) 100Mm X 10Mm , C)Door Handles , I) 75Mm , Ii) 100Mm , Iii) 150Mm , D)Gate Shutter Hook & Eye , I) 100Mm , Ii) 125Mm , Iii) 150Mm , Iv) 250Mm , V) 300Mm , E)Butt Hinge , I) 50Mm X 35Mm X 3.2Mm , Ii) 75Mm X 45Mm X 3.20Mm , Iii) 75Mm X 65Mm X 4Mm , Iv) 100Mm X 63Mm X 3.2Mm , V) 100Mm X 75Mm X 4Mm , F)Pariamentary Hinge , I) 75Mm ( 100Mm X31mm X6.5Mm ) , Ii) 100Mm (50Mm X 22.5Mm X 6.5Mm) , G) Continuous Piano Hinge , 40Mm X .8M , H) Mortice Night Latches , I) Rim Latches , I) 100Mm , Ii) 125Mm , Iii) 150Mm , J) Fan Light Pivot , K) Fan Light Catcher , L) Hydraulic Door Closure , M) Mortice Lock Vertical Type , I) 65Mm( Godrej With Handle(2 Lever) , Ii) 75Mm(Godrej With Handle(4 Lever) , Iii) 100Mm(Godrej With Handle (6 Lever) , Iv) Aldrop With In Built Lock-6 Lever Kadi Tala(Godrej Make) , V) Pin Cylinder Mortise Lock Oliver/Matiz/Victoria -Godrej Make , N) Drawer Locks , I) 40Mm , Ii) 50Mm , Iii) 65Mm , Iv) 75Mm , O) Cupboard Locks , I) 40Mm , Ii) 50Mm , Iii) 65Mm , Iv) 75Mm , P) Finger Plate , Q) Kicking Plate , S) Wardrobe Knob , T) Door Stopper With Rubber Stopper , Brass Fittings , A) Sliding Door Bolts , I) 300Mm X 16Mm , Ii) 250Mm X 16Mm , B) Tower Bolts , I) 300Mm X 10Mm , Ii) 250Mm X 10Mm , Iii) 200Mm X 10Mm , Iv) 150Mm X 10Mm , V) 100Mm X 10Mm , C)Door Handles , I) 75Mm , Ii) 100Mm , Iii) 150Mm , D)Gate Shutter Hook & Eye , I) 100Mm , Ii) 150Mm , Iii)250Mm , Iv) 300Mm , E)Butt Hinge , I) 125Mm X 50Mm X 4Mm , Iii) 100Mm X 50Mm X 4Mm , Iii) 100Mm X 40Mm X 2.5Mm , Iv) 75Mm X 50Mm X 4Mm , V) 75Mm X 40Mm X 2.5Mm , Vi) 50Mm X 40Mm X 2Mm , F)Pariamentary Hinge , I) 75Mm ( 75Mm X20mm X 3.2Mm ) , Ii) 100Mm (100Mm X 27Mm X 5Mm) , Ii) 150Mm (100Mm X 27Mm X 5Mm) , G) Hasp And Staple , I) 90Mm , Ii) 115Mm , Iii) 150Mm , H) Spring Hinge , I) 100Mm , Ii) 125Mm , Iii) 150Mm , I) Flush Bolts , I) 250Mm X 20Mm X 4Mm , Ii) 150Mm X 20Mm X 4Mm , Iii) 100Mm X 20Mm X4mm , J) Door Latches , I) 300Mm X 16Mm X 5Mm , Ii) 250Mm X 16Mm X 5Mm , K) Night Latches , I) Mortice Night Latches (Godrej Make) , Ii. Rim Latches (Godrej Make) , L) Fan Light Pivot , M) Fan Light Catcher , N) Mortice Lockl Vertical Type , I) 65Mm , Ii) 75Mm , O) Mortice Cylindrical Type(Godrej Make)-Polished Brass , P) Drawer Locks , I) 40Mm , Ii) 50Mm , Iii) 65Mm , Iv) 75Mm , Q) Cupboard Locks , I) 40Mm , Ii) 50Mm , Iii) 65Mm , Iv) 75Mm , R) Finger Plate , S) Kicking Plate , U) Wardrobe Knob , V) Door Stopper With Rubber Stopper , W) Ball Catcher , X) Magnet Catcher , Y) Peeping Plate , Door Closer & Floor Spring , A) Godrej , A) Single Speed Door Closer( Size166.5X 48Mmx 67Mm)-Model C071 , B) Double Speed Door Closer( Size 140Mm X 39Mm X 60Mm)- Model Number C 752 , C) Heavy Duty Door Closer( Size 180 Mm X 65Mm X 64Mm) , D) Sleek Door Closer( 215Mm X 51Mm X 45Mm) , E) Concealed Door Closer ( 230Mm X 76.5Mm X 30.5Mm) , Pin (19 X 17) , Pin (19 X 20) , Blind , (A) Vertical Blinds , (A) Regular , I) 100 Mm , Ii)89 Mm , Iii) 75 Mm , Iv) 50 Mm , (B) Blackout , I) 100 Mm , Ii)89 Mm , Iii) 75 Mm , Iv) 50 Mm , (B) Horizontal Blinds , I) 15Mm Micro Blind , Ii) 25 Mm Slim Line Blind , Iii) 25 Mm Perforated Blind , Iv) 25 Mm Printed Blind , V) 25 Mm Dust Guard Blind , Vi) 25 Mm Pearl Finish Blind , Vii) 25 Mm Special Effect Blind , Viii) 25 Mm Timber Blind , Screw 50 X 10 , Screw 25 X 7 , Screw 20 X 6 (Full Tread) , Screw 20 X 7 (Full Tread) , Screws 35 X 8 , Screws 25 X 8 , Screws 15 X 8 , Aluminium Sheet 0.50Mm , Ms Pipe , (I) 25Mm Diameter (Medium) , (Ii) 32Mm Diameter (Medium) , (Iii) 40Mm Diameter (Medium) , (Iv) 50Mm Diameter (Medium) , (V) 65Mm Diameter (Medium) , (Vi) 80Mm Diameter (Medium) , (Vii) 100Mm Diameter (Medium) , (Viii) 125Mm Diameter (Medium) , (Ix) 150Mm Diameter (Medium) , Bituminus Tarfelt , Dr. Fixit Epoxy Bonding Agent 211 , Chowkhat For Door & Window (Sundi / Teak / Gamari) , (A) 4 X 3 , (B) 5 X 3 , 1/3Panelled 2/3 Glazed Wooden Shutters For Doors/Windows Including Oxidised Iron Butt Hinges (100Mm X75 Mm X3.55 Mm) With Necessay Screwsincluding Glass Panes With 1St Class Local Wood (Gamari/Hollock/Bonsum). 40Mm Thick , Providing, Fitting And Fixing Full Panelled Doors/ Windows Including Oxidised M.S Butt Hinges (100Mm X75 Mm X3.55Mm) With Necessary Screws. With 1St Class Local Wood (Gamari/Hollock/Bonsum). 35Mm Thick , Non-Asbestor High Impact Polylropylene Reinforced Cement 6Mm Thick Corrugated Sheets (As Per Is:14871) Roofing Up To Any Pitch And Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Plain And Bitumen Washers Or With Self Drilling Fastner And Epdm Washer Etc. , Boulder For Rubble Masonary With Forest Loyalty, Other Taxes & F.O.R Nit Silchar. , Soft Broom , Hard Broom , Lime Powder , 250Mm Hume Pipe Np2 , 300Mm Hume Pipe Np2 , 450Mm Hume Pipe Np2 , 600Mm Hume Pipe Np2 , 900Mm Hume Pipe Np2 , 250Mm Hume Pipe Np3 , 300Mm Hume Pipe Np3 , 450Mm Hume Pipe Np3 , 600Mm Hume Pipe Np3 , 900Mm Hume Pipe Np3 , Collar 250Mm , Collar 300Mm , Collar 450Mm , Collar 600Mm , Collar 900Mm , Cp Towel Rod Sona Make 450Mm Long , Ceramic Wall Tiles 30Cm X 20Cm Somany / Jonson , Ceramic Floor Tiles 30Cm X 30Cm Somany / Jonson , Ceramic Floor Tiles 30Cm X 30Cm Somany / Jonson (Matt Finish) , Vitrefied Floor Tiles 60Cm X 60Cm Somany / Jonson , Decorative Plastic Bracket With Screws & Clamps For Curtain , Decorative Brass Bracket With Screws & Clamps For Curtain , Decorative Aluminium Bracket With Screws & Clamps For Curtain , Steel Brass , Best Quality Bleaching Powder , Commode Seat Cover (Hindware / Parryware) , Syntex Cover 500 Lits Capacity , Syntex Cover 1000 Lits Capacity , Syntex Cover 2000 Lits Capacity , Syntex Cover 5000 Lits Capacity , Plastic Gutka , Interior Wall Putty (Asian/ Narolac/Jk/Berger) , Cp Gratings (100 Mm) , Cp Soap Tray , Brass Nail , Sink Coupling (100 Mm) , Sink Coupling More Than 100Mm , Cp Couplin (Small Size) 40Mm , Cp Extension Cord 1/2X 3 , Cp Towel Rod Sona Make 600Mm Long , Aluminum Window Stopper , Moisquito Net , Good Quality Flexible Pvc Pipe Pipe - 25Mm (30.00M In Length) , Iron Nail , (A) 1/2 Inch (12.5Mm) , (B) 3/4 Inch (18.25 Mm) , (C ) 1 Inch (25Mm) , (D ) 1.5 Inch (40Mm) , (E) 2 Inch (50Mm) , (F) 2.5 Inch (65Mm) , (G) 3 Inch (75Mm) , (H) 4 Inch (100Mm) , (I) 5 Inch (125Mm) , First Class Timber Scant (Sal/Teak/Sundi) , (A) 25Mm X 25Mm Timber Scant , (A) 25Mm X 50 Mm Timber Scant , (A) 50Mm X 50 Mm Timber Scant , (A) 75Mm X 50 Mm Timber Scant , (A) 75Mm X 75Mm Timber Scant , (C ) 50Mm X 50 Mm Timber Scant , (D) 100 Mm X 75 Mm Timber Scant , (E) 125 Mm X 100 Mm Timber Scant , Iron Hexagonal Bolt , ( A) 75 Mm(L) X 10 Mm(Dia) , (B) 75 Mm(L) X 12 Mm(Dia) , (C ) 75 Mm(L) X 14 Mm(Dia) , (D ) 75 Mm(L) X 16 Mm(Dia) , ( E) 100 Mm(L) X 10 Mm(Dia) , (F) 100 Mm(L) X 12 Mm(Dia) , (G ) 100 Mm(L) X 14 Mm(Dia) , (H ) 100 Mm(L) X 16 Mm(Dia) , Hexagonal Nut With Washer , (A) 10Mm , (B) 12 Mm , (C ) 14 Mm , (D) 16Mm , Roof Srew , Roof Srew Cap (Umbrella Cap) , Pipe Clamp , (A) 63Mm Dia Pipe Clamp (U Shaped) Of Ms Flat , (B) 75Mm Dia Pipe Clamp (U Shaped) Of Ms Flat , (C) 100 Mm Dia Pipe Clamp (U Shaped) Of Ms Flat , (D) 125Mm Dia Pipe Clamp (U Shaped) Of Ms Flat , Murcha Clamp , Gi Wire 24 Swg , Gi Wire 16 Swg , Chiken Wire Mesh , Sand Paper 80 No. , Lime Brass 150Mm , Steel Window Latch 150Mm , Stainless Steel Sink 24 X 12 , Stainless Steel Sink 8 X 12 , Solvent Cement , Sypon , Wash Basin (Make: Hindware) Size: 22 Inch * 18 Inch , Wash Basin With Pedestal (Make: Hindware) Size: 22 Inch * 18 Inch , Pvc Reducer 110Mm X 90Mm , 110Mm Pvc Long Bend (Supreme / Prince) , Pvc Tail Piece 110Mm , 110Mm Dia Door Cap For Door Bend (Make: Prince) , Gi Flange 4 , Taflon Tape , Haxsaw Blade (Double Side) , Cp 15Mm Clamp , Cp 20Mm Clamp , Cp 25Mm Clamp , Nut & Bolt 18 , Godrej Lock Big Size , Godrej Medium Big Size , Godrej Small Big Size , Good Quality Lock Big Size , Good Quality Medium Big Size , Good Quality Small Big Size , Black Putty , Cgi Screw 2 , Cgi Screw Cap 1 , Rubber Gasket , Nut & Washer , Grease (Best Quality) , Aluminium Window Roller , Aluminium Window Rubber , Aluminium Window Lock (Star Lock) , Road Marking Paint (Shalimar Make) , Chowkhat Clamp , Fevicol Sh , Cgi Sheet Ridging 0.63 Mm Thick - 600 Mm Lapping X 1.50M Width , Toilet Tissue Papper With Stand , Herpic 500 Ml , Phenyl Black , Phenyl White , Nepthalin Ball , Washing Powder (Nirma) , Good Quality Wiper , Good Quality Toilet Brass , M.O.P , Sulphuric Acid (600Ml) , Best Quality Empty Plastic Drum 50 Lits Capacity , Best Quality Empty Plastic Drum 100 Lits Capacity , Best Quality Empty Plastic Drum 200 Lits Capacity , Cistern Long Wash Pipe Pvc , Cp Royal Make Stop Cock Concealed , Cp Hand Shower With Pipe Royal / Jaquar Make , Cp 2 In 1 Bib Cock (Royal / Jaquar Make) , Cp 2 In 1 Bib Cock With Hand Shower (Marc / Royal) , Brash Spandle 15Mm , Plastic Bucket 10Lits (Cello) , Plastic Mug 1 Lit (Cello / Milton) , Steel Altala 4 , Odonil 73Mm , Odonil 48Mm , Odonil Gel Base 75Mm , Bleaching Powder , Washing Powder , Hydrochloric Acid (Lit)/Suitable Floor Cleaner , Spin Mop With Extendable Handle Stainless Steel Rod With Replacement Mop Refill , Heavy Dusting Dusting Cloth Of 2 X 2 , Citronala 50Ml , Good Quality Cowdung , Urea , Melathin , D.O.P , Potash , Round Up Chemical (Ustaad) , Good Quality Earth (Polymathi) , Pipe Wrench 12. Make: Taparia , Pipe Wrench 14. Make: Taparia , Pipe Wrench 18. Make: Taparia , Adjustable Wrench 12. Make: Taparia , Adjustable Wrench 18. Make: Taparia , Pipe Die Set , Monkey Wrench 12 , Hammper 500 Gm , Hammper 1000 Gm , Haxo Frame , Haxo Blade Double Side , Screw Driver 8. Make: Taparia , Screw Driver 10. Make: Taparia , Screw Driver 12. Make: Taparia , Plyier 8 , Drill Machine. Make Jk/Iti , Good Quality Wood Panon , Triangular File 4 , Glass Cutter , Chisel 40Mm , Chisel 25Mm , Chisel 20Mm , Combination Stone (Taparia) , Ball Pen Hammer (Tata) 500Gm , Ball Pen Hammer (Tata) 200Gm , Tenant Saw 16 , Pliers 8 (Tata) , Hss Drill Bit 6.5Mm , Hss Drill Bit 8Mm , Hss Drill Bit 10Mm , Hss Drill Bit 12Mm , Hss Drill Bit 16Mm , Hammer Drill Machine. Make Jk / Iti , Masonry Hammer Drill Bit 6Mm , Masonry Hammer Drill Bit 8Mm , Masonry Hammer Drill Bit 10Mm , Masonry Hammer Drill Bit 12Mm , Flat Chisel 6 , Flat Chisel 8 , Cpvc Pipe Sdr 11 3Mtr Length 15Mm , Cpvc Pipe Sdr 11 3Mtr Length 20Mm , Cpvc Pipe Sdr 11 3Mtr Length 25 Mm , Cpvc Pipe Sdr 11 3Mtr Length 32Mm , Cpvc Pipe Sdr 11 3Mtr Length 40Mm , Cpvc Pipe Sdr 11 3Mtr Length 50Mm , Cpvc Pipe Sdr 13.5 3Mtr Length 15Mm , Cpvc Pipe Sdr 13.5 3Mtr Length 20Mm , Cpvc Pipe Sdr 13.5 3Mtr Length 25Mm , Cpvc Pipe Sdr 13.5 3Mtr Length 32Mm , Cpvc Pipe Sdr 13.5 3Mtr Length 40Mm , Cpvc Pipe Sdr 13.5 3Mtr Length 50Mm , Cpvc Elbow 90 Degree 15Mm , Cpvc Elbow 90 Degree 20Mm , Cpvc Elbow 90 Degree 25Mm , Cpvc Elbow 90 Degree 32Mm , Cpvc Elbow 90 Degree 40Mm , Cpvc Elbow 90 Degree 50Mm , Cpvc Reducer Elbow 90 Degree 20X15mm , Cpvc Reducer Elbow 90 Degree 25X15mm , Cpvc Reducer Elbow 90 Degree 25X20mm , Cpvc Reducer Elbow 90 Degree 32X20mm , Cpvc Reducer Elbow 90 Degree 32X25mm , Cpvc Reducer Elbow 90 Degree 40X20mm , Cpvc Reducer Elbow 90 Degree 40X25mm , Cpvc Reducer Elbow 90 Degree 40X32mm , Cpvc Reducer Elbow 90 Degree 50X20mm , Cpvc Reducer Elbow 90 Degree 50X25mm , Cpvc Reducer Elbow 90 Degree 50X32mm , Cpvc Reducer Elbow 90 Degree 50X40mm , Cpvc Tee 15Mm , Cpvc Tee 20Mm , Cpvc Tee 25Mm , Cpvc Tee 32Mm , Cpvc Tee 40Mm , Cpvc Tee50mm , Cpvc Coupler 15Mm , Cpvc Coupler 20Mm , Cpvc Coupler 25Mm , Cpvc Coupler 32Mm , Cpvc Coupler 40Mm , Cpvc Coupler 50Mm , Cpvc Male Adapter Plastic Threaded 15Mm , Cpvc Male Adapter Plastic Threaded 20Mm , Cpvc Male Adapter Plastic Threaded 25Mm , Cpvc Male Adapter Plastic Threaded 32Mm , Cpvc Male Adapter Plastic Threaded 40Mm , Cpvc Male Adapter Plastic Threaded 50Mm , Cpvc Reducing Male Adapter Plastic Threaded 20X15mm , Cpvc Reducing Male Adapter Plastic Threaded 25X20mm , Cpvc Female Adapter Plastic Threaded 15Mm , Cpvc Female Adapter Plastic Threaded 20Mm , Cpvc Female Adapter Plastic Threaded 25Mm , Cpvc Female Adapter Plastic Threaded 32Mm , Cpvc Female Adapter Plastic Threaded 40Mm , Cpvc Female Adapter Plastic Threaded 50Mm , Cpvc Union 15Mm , Cpvc Union 20Mm , Cpvc Union 25Mm , Cpvc Union 32Mm , Cpvc Union 40Mm , Cpvc Union 50Mm , Cpvc End Cap 15Mm , Cpvc End Cap 20Mm , Cpvc End Cap 25Mm , Cpvc End Cap 32Mm , Cpvc End Cap 40Mm , Cpvc End Cap 50Mm , Cpvc Tank Nipple 15Mm , Cpvc Tank Nipple 20Mm , Cpvc Tank Nipple 25Mm , Cpvc Tank Nipple 32Mm , Cpvc Tank Nipple 40Mm , Cpvc Tank Nipple 50Mm , Cpvc Tank Nipple(With One Side Pipr Fitment) 20Mm , Cpvc Tank Nipple(With One Side Pipr Fitment) 25Mm , Cpvc Tank Nipple(With One Side Pipr Fitment) 32Mm , Cpvc Tank Nipple(With One Side Pipr Fitment) 40Mm , Cpvc Tank Nipple(With One Side Pipr Fitment) 50Mm , Cpvc Hex Nipple 20Mm , Cpvc Hex Nipple 25Mm , Cpvc Hex Nipple 32Mm , Cpvc Hex Nipple 40Mm , Cpvc Hex Nipple 50Mm , Cpvc Elbow 45 Degree 15Mm , Cpvc Elbow 45 Degree 20Mm , Cpvc Elbow 45 Degree 25Mm , Cpvc Elbow 45 Degree 32Mm , Cpvc Elbow 45 Degree 40Mm , Cpvc Elbow 45 Degree 50Mm , Cpvc 3 Way Elbow 20Mm , Cpvc Reducer Coupler 20X15mm , Cpvc Reducer Coupler 25X15mm , Cpvc Reducer Coupler 25X20mm , Cpvc Reducer Coupler 32X15mm , Cpvc Reducer Coupler 32X20mm , Cpvc Reducer Coupler 32X25mm , Cpvc Reducer Coupler 40X15mm , Cpvc Reducer Coupler 40X20mm , Cpvc Reducer Coupler 40X25mm , Cpvc Reducer Coupler 40X32mm , Cpvc Reducer Coupler 50X15mm , Cpvc Reducer Coupler 50X20mm , Cpvc Reducer Coupler 50X25mm , Cpvc Reducer Coupler 50X32mm , Cpvc Reducer Coupler 50X40mm , Cpvc Converter Bushing 15Mm , Cpvc Converter Bushing 20Mm , Cpvc Converter Bushing 25Mm , Cpvc Converter Bushing 32Mm , Cpvc Converter Bushing 40Mm , Cpvc Converter Bushing 50Mm , Cpvc Bushing 20X15mm , Cpvc Bushing 25X15mm , Cpvc Bushing 25X20mm , Cpvc Bushing 32X15mm , Cpvc Bushing 32X20mm , Cpvc Bushing 32X25mm , Cpvc Bushing 40X15mm , Cpvc Bushing 40X20mm , Cpvc Bushing 40X25mm , Cpvc Bushing 40X32mm , Cpvc Bushing 50X15mm , Cpvc Bushing 50X20mm , Cpvc Bushing 50X25mm , Cpvc Bushing 50X32mm , Cpvc Bushing 50X40mm , Cpvc Reducer Tee 15X15x20mm , Cpvc Reducer Tee 20X15x15mm , Cpvc Reducer Tee 20X15x20mm , Cpvc Reducer Tee 20X20x15mm , Cpvc Reducer Tee 25X25x15mm , Cpvc Reducer Tee 25X25x20mm , Cpvc Reducer Tee 32X32x15mm , Cpvc Reducer Tee 32X32x20mm , Cpvc Reducer Tee 32X32x25mm , Cpvc Reducer Tee 40X40x15mm , Cpvc Reducer Tee 40X40x20mm , Cpvc Reducer Tee 40X40x25mm , Cpvc Reducer Tee 40X40x32mm , Cpvc Reducer Tee 50X50x15mm , Cpvc Reducer Tee 50X50x20mm , Cpvc Reducer Tee 50X50x25mm , Cpvc Reducer Tee 50X50x32mm , Cpvc Reducer Tee 50X50x40mm , Cpvc Brass Elbow 90 Degree 15X15mm , Cpvc Brass Elbow 90 Degree 20X15mm , Cpvc Brass Elbow 90 Degree 20X20mm , Cpvc Brass Elbow 90 Degree 25X15mm , Cpvc Brass Elbow 90 Degree 25X20mm , Cpvc Brass Elbow 90 Degree 25X25mm , Cpvc Brass Elbow 90 Degree 32X15mm , Cpvc Brass Elbow 90 Degree 32X20mm , Cpvc Brass Elbow 90 Degree 32X32mm , Cpvc Brass Elbow With Clamp 20X15mm , Cpvc Brass Tee 15X15x15mm , Cpvc Brass Tee 20X20x15mm , Cpvc Brass Tee 20X20x20mm , Cpvc Brass Tee 25X25x15mm , Cpvc Brass Tee 25X25x20mm , Cpvc Brass Tee 25X25x25mm , Cpvc Brass Tee 32X32x15mm , Cpvc Male Adapter Brass Threaded 15Mm , Cpvc Male Adapter Brass Threaded 20Mm , Cpvc Male Adapter Brass Threaded 25Mm , Cpvc Male Adapter Brass Threaded 32Mm , Cpvc Male Adapter Brass Threaded 40Mm , Cpvc Male Adapter Brass Threaded 50Mm , Cpvc Male Adapter Brass Threaded 65Mm , Cpvc Male Adapter Brass Threaded 80Mm , Cpvc Reducing Male Adapter Brass Threaded 20X15mm , Cpvc Reducing Male Adapter Brass Threaded 25X15mm , Cpvc Reducing Male Adapter Brass Threaded 25X20mm , Cpvc Union Male Adapter Brass Threaded 20Mm , Cpvc Union Male Adapter Brass Threaded 25Mm , Cpvc Female Adapter Brass Threaded 15Mm , Cpvc Female Adapter Brass Threaded 20Mm , Cpvc Female Adapter Brass Threaded 25Mm , Cpvc Female Adapter Brass Threaded 32Mm , Cpvc Female Adapter Brass Threaded 40Mm , Cpvc Female Adapter Brass Threaded 50Mm , Cpvc Female Adapter Brass Threaded 65Mm , Cpvc Female Adapter Brass Threaded 80Mm , Cpvc Reducing Female Adapter Brass Threaded 20X15mm , Cpvc Reducing Female Adapter Brass Threaded 25X15mm , Cpvc Reducing Female Adapter Brass Threaded 25X20mm , Cpvc Reducing Female Adapter Brass Threaded 32X15mm , Cpvc Union Female Adapter Brass Threaded 20Mm , Cpvc Union Female Adapter Brass Threaded 25Mm , Cpvc Brass Elbow Male Adapter Brass Threaded 20X15mm , Cpvc Brass Tee Male Adapter Brass Threaded 20X20x15mm , Cpvc Brass Elbow Long 20X15mm , Cpvc 3 In 1 Mixer Adapter All Top(6) 20X15mm , Cpvc 3 In 1 Mixer Adapter All Top(6) 25X15mm , Cpvc Top And Bottom (6) 20X15mm , Cpvc Top And Bottom (6) 25X15mm , Cpvc Top And Side (6) 20X15mm , Cpvc Top And Side (6) 25X15mm , Cpvc Hot Up And Cold Down (6) 20X15mm , Cpvc Hot Up And Cold Down (6) 25X15mm , Cpvc Hot Side And Cold Down (6) 20X15mm , Cpvc Hot Side And Cold Down (6) 25X15mm , Cpvc All Top (7) 20X15mm , Cpvc All Top (7) 25X15mm , Cpvc Top And Bottom (7) 20X15mm , Cpvc Top And Bottom (7) 25X15mm , Cpvc Top And Side (7) 20X15mm , Cpvc Top And Side (7) 25X15mm , Cpvc Hot Up And Cold Down (7) 20X15mm , Cpvc Hot Up And Cold Down (7) 25X15mm , Cpvc Hot Side And Cold Down (7) 20X15mm , Cpvc Hot Side And Cold Down (7) 25X15mm , Cpvc 3 In 1 Mixer Adapter With Mabt Top 20X15mm , Cpvc 3 In 1 Mixer Adapter With Mabt Bottom 20X15mm , Cpvc 3 In 1 Mixer Adapter With Mabt Top And Side 20X15mm , Cpvc Kitchen Mixer Adaptor Down 20X15mm , Cpvc Kitchen Mixer Adaptor Straight 20X15mm , Cpvc Extension Nipple 15X25mm , Cpvc Extension Nipple 15X40mm , Cpvc Extension Nipple 15X50mm , Cpvc Extension Nipple 15X65mm , Cpvc Extension Nipple 15X80mm , Cpvc Ball Valve 15Mm , Cpvc Ball Valve 20Mm , Cpvc Ball Valve 25Mm , Cpvc Ball Valve 32Mm , Cpvc Ball Valve 40Mm , Cpvc Ball Valve 50Mm , Cpvc Ball Valve With Brass Threaded (One Side) 20Mm , Cpvc Ball Valve With Brass Threaded (One Side) 25Mm , Cpvc Ball Valve With Brass Threaded (One Side) 32Mm , Cpvc Ball Valve With Brass Threaded (Two Side) 20Mm , Cpvc Ball Valve With Brass Threaded (Two Side) 25Mm , Cpvc Ball Valve With Brass Threaded (Two Side) 32Mm , Cpvc Ball Valve Handle 15Mm , Cpvc Ball Valve Handle 20Mm , Cpvc Ball Valve Handle 25Mm , Cpvc Ball Valve Handle 32Mm , Cpvc Ball Valve Handle 40Mm , Cpvc Ball Valve Handle 50Mm , Cpvc Non Return Valve 20Mm , Cpvc Non Return Valve 25Mm , Cpvc Cross Tee 15Mm , Cpvc Cross Tee 20Mm , Cpvc Cross Tee 25Mm , Cpvc Tee Holder 15X15x15mm , Cpvc Tee Holder 20X20x15mm , Cpvc Tee Holder 25X25x15mm , Cpvc Elbow Holder 15X15mm , Cpvc Elbow Holder 15X20mm , Cpvc Threaded End Plug 15Mm , Cpvc Threaded End Plug 20Mm , Cpvc Expansion Loop 15Mm , Cpvc Expansion Loop 20Mm , Cpvc Expansion Loop 25Mm , Cpvc Expansion Loop 32Mm , Cpvc Expansion Loop 40Mm , Cpvc Expansion Loop 50Mm , Cpvc Step Over Bend 15Mm , Cpvc Step Over Bend 20Mm , Cpvc Step Over Bend 25Mm , Cpvc Step Over Bend 32Mm , Cpvc Step Over Bend 40Mm , Cpvc Step Over Bend 50Mm , Cpvc Short Bend 15Mm , Cpvc Short Bend 20Mm , Cpvc Short Bend 25Mm , Cpvc Short Bend 32Mm , Cpvc Short Bend 40Mm , Cpvc Short Bend 50Mm , Cpvc Sweep Bend - Socket At Both Side 20Mm , Cpvc Sweep Bend - Socket At Both Side 25Mm , Cpvc Sweep Bend - Socket At Both Side 32Mm , Cpvc Flange With Gasket - End Cap Open 25Mm , Cpvc Flange With Gasket - End Cap Open 32Mm , Cpvc Flange With Gasket - End Cap Open 40Mm , Cpvc Flange With Gasket - End Cap Open 50Mm , Cpvc Flange With Gasket - End Cap Closed 25Mm , Cpvc Flange With Gasket - End Cap Closed 32Mm , Cpvc Flange With Gasket - End Cap Closed 40Mm , Cpvc Flange With Gasket - End Cap Closed 50Mm , Cpvc Long Concealed Valve 15Mm Quarter Triangle , Cpvc Long Concealed Valve 15Mm Quarter Square , Cpvc Long Concealed Valve 15Mm Quarter Round , Cpvc Long Concealed Valve 15Mm Quarter Plastic (Cp) , Cpvc Long Concealed Valve 15Mm Full Triangle , Cpvc Long Concealed Valve 15Mm Full Square , Cpvc Long Concealed Valve 15Mm Full Round , Cpvc Long Concealed Valve 15Mm Full Plastic (Cp) , Cpvc Long Concealed Valve 20Mm Quarter Triangle , Cpvc Long Concealed Valve 20Mm Quarter Square , Cpvc Long Concealed Valve 20Mm Quarter Round , Cpvc Long Concealed Valve 20Mm Quarter Plastic (Cp) , Cpvc Long Concealed Valve 20Mm Full Triangle , Cpvc Long Concealed Valve 20Mm Full Square , Cpvc Long Concealed Valve 20Mm Full Round , Cpvc Long Concealed Valve 20Mm Full Plastic (Cp) , Cpvc Long Concealed Valve 25Mm Quarter Triangle , Cpvc Long Concealed Valve 25Mm Quarter Square , Cpvc Long Concealed Valve 25Mm Quarter Round , Cpvc Long Concealed Valve 25Mm Quarter Plastic (Cp) , Cpvc Long Concealed Valve 25Mm Full Triangle , Cpvc Long Concealed Valve 25Mm Full Square , Cpvc Long Concealed Valve 25Mm Full Round , Cpvc Long Concealed Valve 25Mm Full Plastic (Cp) , Cpvc Short Concealed Valve 15Mm Quarter Triangle , Cpvc Short Concealed Valve 15Mm Quarter Square , Cpvc Short Concealed Valve 15Mm Quarter Round , Cpvc Short Concealed Valve 15Mm Quarter Plastic (Cp) , Cpvc Short Concealed Valve 15Mm Full Triangle , Cpvc Short Concealed Valve 15Mm Full Square , Cpvc Short Concealed Valve 15Mm Full Round , Cpvc Short Concealed Valve 15Mm Full Plastic (Cp) , Cpvc Short Concealed Valve 20Mm Quarter Triangle , Cpvc Short Concealed Valve 20Mm Quarter Square , Cpvc Short Concealed Valve 20Mm Quarter Round , Cpvc Short Concealed Valve 20Mm Quarter Plastic (Cp) , Cpvc Short Concealed Valve 20Mm Full Triangle , Cpvc Short Concealed Valve 20Mm Full Square , Cpvc Short Concealed Valve 20Mm Full Round , Cpvc Short Concealed Valve 20Mm Full Plastic (Cp) , Cpvc Short Concealed Valve 25Mm Quarter Triangle , Cpvc Short Concealed Valve 25Mm Quarter Square , Cpvc Short Concealed Valve 25Mm Quarter Round , Cpvc Short Concealed Valve 25Mm Quarter Plastic (Cp) , Cpvc Short Concealed Valve 25Mm Full Triangle , Cpvc Short Concealed Valve 25Mm Full Square , Cpvc Short Concealed Valve 25Mm Full Round , Cpvc Short Concealed Valve 25Mm Full Plastic (Cp) , Cpvc Concealed Valve Quarter Turn- Mini Spindle With Plastic Knob 15Mm , Cpvc Concealed Valve Quarter Turn- Mini Spindle With Plastic Knob 20Mm , Cpvc Concealed Valve Quarter Turn- Mini Spindle With Plastic Knob 25Mm , Cpvc Single Lever Concraled Diverter (Tap& Shower) 20Mm (Working Condition At 0.8/ Input Pressure Medium Flow) , Cpvc Single Lever Concraled Diverter (Tap& Shower) 20Mm (Working Condition At 0.5/ Input Pressure High Flow) , Cpvc Front Plates For Single Lever Concealed Diverter ( Tap And Shower- Medium Flow) Oval Design , Cpvc Front Plates For Single Lever Concealed Diverter ( Tap And Shower- Medium Flow) Arch Design , Cpvc Front Plates For Single Lever Concealed Diverter ( Tap And Shower- Medium Flow) Round Design , Cpvc Front Plates For Single Lever Concealed Diverter ( Tap And Shower- High Flow) Oval Design , Cpvc Front Plates For Single Lever Concealed Diverter ( Tap And Shower- High Flow) Arch Design , Cpvc Front Plates For Single Lever Concealed Diverter ( Tap And Shower- High Flow) Round Design , Cpvc Single Lever Concealed Diverter (Shower) 20Mm , Cpvc Front Plates For Single Lever Concealed Diverter (Shower) Oval Design , Cpvc Front Plates For Single Lever Concealed Diverter (Shower) Arch Design , Cpvc Front Plates For Single Lever Concealed Diverter (Shower) Round Design , Cpvc Flush Valve 32X32mm , Cpvc Flush Valve 40X32mm , Cpvc Y- Strainer 25Mm , Cpvc Y- Strainer 32Mm , Cpvc Water Hammer Arrestor Type A 15X15x15mm , Cpvc Water Hammer Arrestor Type B 20X20x20mm , Cpvc Plastic Clamp 15Mm , Cpvc Plastic Clamp 20Mm , Cpvc Plastic Clamp 25Mm , Cpvc Plastic Clamp 32Mm , Cpvc Plastic Clamp 40Mm , Cpvc Plastic Clamp 50Mm , Cpvc Ss Clamp 15Mm , Cpvc Ss Clamp 20Mm , Cpvc Ss Clamp 25Mm , Cpvc Ss Clamp 32Mm , Cpvc Ss Clamp 40Mm , Cpvc Ss Clamp 50Mm , Cpvc Power Coated Metal Clamp 15Mm , Cpvc Power Coated Metal Clamp 20Mm , Cpvc Power Coated Metal Clamp 25Mm , Cpvc Power Coated Metal Clamp 32Mm , Cpvc Power Coated Metal Clamp 40Mm , Cpvc Power Coated Metal Clamp 50Mm , Cpvc Rubber Washer-Tank Nipple 15Mm , Cpvc Rubber Washer-Tank Nipple 20Mm , Cpvc Rubber Washer-Tank Nipple 25Mm , Cpvc Rubber Washer-Tank Nipple 32Mm , Cpvc Rubber Washer-Tank Nipple 40Mm , Cpvc Rubber Washer-Tank Nipple 50Mm , Cpvc Rubber Washer-Union 15Mm , Cpvc Rubber Washer-Union 20Mm , Cpvc Rubber Washer-Union 25Mm , Cpvc Rubber Washer-Union 32Mm , Cpvc Rubber Washer-Union 40Mm , Cpvc Rubber Washer-Union 50Mm , Cpvc Rubber Washer- Fapt 15Mm , Cpvc Rubber Washer- Fapt 20Mm , Cpvc Rubber Washer- Fapt 25Mm , Cpvc Rubber Washer- Fapt 32Mm , Cpvc Rubber Washer- Fapt 40Mm , Cpvc Rubber Washer- Fapt 50Mm , Cpvc Yellow Medium Solvent Cement 15Ml Tube , Cpvc Yellow Medium Solvent Cement 29.5Ml Tube , Cpvc Yellow Medium Solvent Cement 59Ml Tube , Cpvc Yellow Medium Solvent Cement 59Ml Tin , Cpvc Yellow Medium Solvent Cement 118Ml Tin , Cpvc Yellow Medium Solvent Cement 237Ml Tin , Cpvc Yellow Medium Solvent Cement 473Ml Tin , Cpvc Yellow Medium Solvent Cement 946Ml Tin , Cpvc Heavy Duty Orange Solvent Cement 118Ml Tin , Cpvc Heavy Duty Orange Solvent Cement 237Ml Tin , Cpvc Heavy Duty Orange Solvent Cement 473Ml Tin , Cpvc Heavy Duty Orange Solvent Cement 946Ml Tin , Cpvc Purple Primar Solvent Cement 237Ml Tin , Cpvc Solvent Cement- Brush , Cpvc Pipe 3Mtr. Length (Sch 40) 65Mm , Cpvc Pipe 3Mtr. Length (Sch 40) 80Mm , Cpvc Pipe 3Mtr. Length (Sch 40) 100Mm , Cpvc Pipe 3Mtr. Length (Sch 40) 150Mm , Cpvc Pipe 3Mtr. Length (Sch 80) 65Mm , Cpvc Pipe 3Mtr. Length (Sch 80) 80Mm , Cpvc Pipe 3Mtr. Length (Sch 80) 100Mm , Cpvc Pipe 3Mtr. Length (Sch 80) 150Mm , Cpvc Elbow 90 Degree 65Mm , Cpvc Elbow 90 Degree 80Mm , Cpvc Elbow 90 Degree 100Mm , Cpvc Elbow 90 Degree 150Mm , Cpvc Tee 90 Degree 65Mm , Cpvc Tee 90 Degree 80Mm , Cpvc Tee 90 Degree 100Mm , Cpvc Tee 90 Degree 150Mm , Cpvc Coupler 65Mm , Cpvc Coupler 80Mm , Cpvc Coupler 100Mm , Cpvc Coupler 150Mm , Cpvc End Cap 65Mm , Cpvc End Cap 80Mm , Cpvc End Cap 100Mm , Cpvc End Cap 150Mm , Cpvc Flange -End Cap Open 65Mm , Cpvc Flange -End Cap Open 80Mm , Cpvc Flange -End Cap Open 100Mm , Cpvc Flange -End Cap Open 150Mm , Cpvc Flange -End Cap Closed 65Mm , Cpvc Flange -End Cap Closed 80Mm , Cpvc Flange -End Cap Closed 100Mm , Cpvc Flange -End Cap Closed 150Mm , Cpvc Rubber Gasket For Flange 25Mm , Cpvc Rubber Gasket For Flange 32Mm , Cpvc Rubber Gasket For Flange 40Mm , Cpvc Rubber Gasket For Flange 50Mm , Cpvc Rubber Gasket For Flange 65Mm , Cpvc Rubber Gasket For Flange 80Mm , Cpvc Rubber Gasket For Flange 100Mm , Cpvc Rubber Gasket For Flange 150Mm , Cpvc Short Bend 65Mm , Cpvc Short Bend 80Mm , Cpvc Short Bend 100Mm , Cpvc Short Bend 150Mm , Cpvc Reducer Coupler 65X20mm , Cpvc Reducer Coupler 65X25mm , Cpvc Reducer Coupler 65X32mm , Cpvc Reducer Coupler 65X40mm , Cpvc Reducer Coupler 65X50mm , Cpvc Reducer Coupler 80X50mm , Cpvc Reducer Coupler 80X65mm , Cpvc Reducer Tee 65X20mm , Cpvc Reducer Tee 65X25mm , Cpvc Reducer Tee 65X32mm , Cpvc Reducer Tee 65X40mm , Cpvc Reducer Tee 65X50mm , Cpvc Reducer Tee 80X50mm , Cpvc Reducer Tee 80X65mm , Cpvc Female Adapter Plastic Threaded- Fapt 65Mm , Cpvc Female Adapter Plastic Threaded- Fapt 80Mm , Cpvc Female Adapter Plastic Threaded- Fapt 100Mm , Cpvc Male Adapter Plastic Threaded- Mapt 65Mm , Cpvc Male Adapter Plastic Threaded- Mapt 80Mm , Cpvc Male Adapter Plastic Threaded- Mapt 100Mm , Cpvc Bushing (Sch 80) 65X50mm , Cpvc Bushing (Sch 80) 80X50mm , Cpvc Bushing (Sch 80) 80X65mm , Cpvc Bushing (Sch 80) 100X50mm , Cpvc Bushing (Sch 80) 100X65mm , Cpvc Bushing (Sch 80) 100X80mm , Cpvc Bushing (Sch 40) 15X50mm , Cpvc Bushing (Sch 40) 15X65mm , Cpvc Bushing (Sch 40) 15X80mm , Cpvc Bushing (Sch 40) 15X100mm , Cpvc Elbow 45 Degree 65Mm , Cpvc Elbow 45 Degree 80Mm , Cpvc Elbow 45 Degree 100Mm , Cpvc Union 65Mm , Cpvc Union 80Mm , Cpvc Union 100Mm , Cpvc Ss Bolts For Butterfly Valves M12x125mm , Cpvc Ss Bolts For Butterfly Valves M16x125mm , Cpvc Ss Bolts For Butterfly Valves M16x150mm , Cpvc Ss Bolts For Butterfly Valves M16x160mm , Cpvc Butterfly Valve 40Mm , Cpvc Butterfly Valve 50Mm , Cpvc Butterfly Valve 65Mm , Cpvc Butterfly Valve 80Mm , Cpvc Butterfly Valve 100Mm , Cpvc Butterfly Valve 150Mm , Cpvc Ball Valve 65Mm , Cpvc Ball Valve 80Mm , Cpvc Ball Valve 100Mm , Body In Cpvc 15Mm , Body In Cpvc 20Mm , Body In Cpvc 25Mm , Cpvc Brass Mechanism Long, Qt 15Mm And 20Mm , Cpvc Brass Mechanism Long, Ft 15Mm And 20Mm , Cpvc Brass Mechanism Short, Qt 15Mm And 20Mm , Cpvc Brass Mechanism Short, Ft 15Mm And 20Mm , Cpvc Brass Mechanism Long, Qt 25Mm , Cpvc Brass Mechanism Long, Ft 25Mm , Cpvc Brass Mechanism Short, Qt 25Mm , Cpvc Brass Mechanism Short, Ft 25Mm , Cpvc Extension Tube Long , Cpvc Extension Tube Short , Cpvc Flange , Cpvc Knobs Plastic , Cpvc Knobs Round , Cpvc Knobs Square , Cpvc Knobs Triangle , Cpvc Ceramic Disc , Allen Key (For Round Knob) , Grub Screw (For Round Knob) , Screw With Washer (For Triangle And Square Knob) , Red & Blue Buttons , Rubber Washer , Cpvc Threaded End Plug , Spindle Medium Flow , Spindle High Flow , Sleeve Flange Medium Flow , Sleeve Flange High Flow , Body Sleeve And O-Ring Medium Flow , Body Sleeve And O-Ring High Flow , Cartrige Medium Flow , Cartrige High Flow , Hex Nut Medium Flow , Hex Nut High Flow , Extension Tube High Flow , Fv Operating Mechanism , Fv Wall Flange With Washer , Ys Filter Mesh 25Mm , Ys Filter Mesh 32Mm , Ys Hex Nut 25Mm , Ys Hex Nut 32Mm , Upvc Pipes (Sch 40) 3 Mtr Length 15Mm , Upvc Pipes (Sch 40) 3 Mtr Length 20Mm , Upvc Pipes (Sch 40) 3 Mtr Length 25Mm , Upvc Pipes (Sch 40) 3 Mtr Length 32Mm , Upvc Pipes (Sch 40) 3 Mtr Length 40Mm , Upvc Pipes (Sch 40) 3 Mtr Length 50Mm , Upvc Pipes (Sch 40) 3 Mtr Length 65Mm , Upvc Pipes (Sch 40) 3 Mtr Length 80Mm , Upvc Pipes (Sch 40) 3 Mtr Length 100Mm , Upvc Pipes (Sch 40) 3 Mtr Length 150Mm , Upvc Pipes (Sch 80) 3 Mtr Length 15Mm , Upvc Pipes (Sch 80) 3 Mtr Length 20Mm , Upvc Pipes (Sch 80) 3 Mtr Length 25Mm , Upvc Pipes (Sch 80) 3 Mtr Length 32Mm , Upvc Pipes (Sch 80) 3 Mtr Length 40Mm , Upvc Pipes (Sch 80) 3 Mtr Length 50Mm , Upvc Pipes (Sch 80) 3 Mtr Length 65Mm , Upvc Pipes (Sch 80) 3 Mtr Length 80Mm , Upvc Pipes (Sch 80) 3 Mtr Length 100Mm , Upvc Pipes (Sch 80) 3 Mtr Length 150Mm , Upvc Elbow 90 Degree (Sch 80) 15Mm , Upvc Elbow 90 Degree (Sch 80) 20Mm , Upvc Elbow 90 Degree (Sch 80) 25Mm , Upvc Elbow 90 Degree (Sch 80) 32Mm , Upvc Elbow 90 Degree (Sch 80) 40Mm , Upvc Elbow 90 Degree (Sch 80) 50Mm , Upvc Elbow 90 Degree (Sch 80) 65Mm , Upvc Elbow 90 Degree (Sch 80) 80Mm , Upvc Elbow 90 Degree (Sch 80) 100Mm , Upvc Elbow 90 Degree (Sch 80) 150Mm , Upvc Union (Sch 80) 15Mm , Upvc Union (Sch 80) 20Mm , Upvc Union (Sch 80) 25Mm , Upvc Union (Sch 80) 32Mm , Upvc Union (Sch 80) 40Mm , Upvc Union (Sch 80) 50Mm , Upvc Union (Sch 80) 65Mm , Upvc Union (Sch 80) 80Mm , Upvc Union (Sch 80) 100Mm , Upvc Union (Sch 80) 150Mm , Upvc Tee (Sch 80) 15Mm , Upvc Tee (Sch 80) 20Mm , Upvc Tee (Sch 80) 25Mm , Upvc Tee (Sch 80) 32Mm , Upvc Tee (Sch 80) 40Mm , Upvc Tee (Sch 80) 50Mm , Upvc Tee (Sch 80) 65Mm , Upvc Tee (Sch 80) 80Mm , Upvc Tee (Sch 80) 100Mm , Upvc Tee (Sch 80) 150Mm , Upvc Tank Nipple (Sch 80) 15Mm , Upvc Tank Nipple (Sch 80) 20Mm , Upvc Tank Nipple (Sch 80) 25Mm , Upvc Tank Nipple (Sch 80) 32Mm , Upvc Tank Nipple (Sch 80) 40Mm , Upvc Tank Nipple (Sch 80) 50Mm , Upvc Tank Nipple (Sch 80) 65Mm , Upvc Tank Nipple (Sch 80) 80Mm , Upvc Tank Nipple (Sch 80) 100Mm , Upvc Tank Nipple (With One Side Pipe Fitment) 20Mm , Upvc Tank Nipple (With One Side Pipe Fitment) 25Mm , Upvc Tank Nipple (With One Side Pipe Fitment) 32Mm , Upvc Tank Nipple (With One Side Pipe Fitment) 40Mm , Upvc Tank Nipple (With One Side Pipe Fitment) 50Mm , Upvc Hex Nipple 20Mm , Upvc Hex Nipple 25Mm , Upvc Hex Nipple 32Mm , Upvc Hex Nipple 40Mm , Upvc Hex Nipple 50Mm , Upvc Coupler (Sch 80) 15Mm , Upvc Coupler (Sch 80) 20Mm , Upvc Coupler (Sch 80) 25Mm , Upvc Coupler (Sch 80) 32Mm , Upvc Coupler (Sch 80) 40Mm , Upvc Coupler (Sch 80) 50Mm , Upvc Coupler (Sch 80) 65Mm , Upvc Coupler (Sch 80) 80Mm , Upvc Coupler (Sch 80) 100Mm , Upvc Coupler (Sch 80) 150Mm , Upvc Converter Coupler 25Mm , Upvc Converter Coupler 32Mm , Upvc Converter Coupler 40Mm , Upvc Converter Coupler 50Mm , Upvc Female Adapter Plastic Threaded - Fapt 15Mm , Upvc Female Adapter Plastic Threaded - Fapt 20Mm , Upvc Female Adapter Plastic Threaded - Fapt 25Mm , Upvc Female Adapter Plastic Threaded - Fapt 32Mm , Upvc Female Adapter Plastic Threaded - Fapt 40Mm , Upvc Female Adapter Plastic Threaded - Fapt 50Mm , Upvc Female Adapter Plastic Threaded - Fapt 65Mm , Upvc Female Adapter Plastic Threaded - Fapt 80Mm , Upvc Female Adapter Plastic Threaded - Fapt 100Mm , Upvc Male Adapter Plastic Threaded - Fapt 15Mm , Upvc Male Adapter Plastic Threaded - Fapt 20Mm , Upvc Male Adapter Plastic Threaded - Fapt 25Mm , Upvc Male Adapter Plastic Threaded - Fapt 32Mm , Upvc Male Adapter Plastic Threaded - Fapt 40Mm , Upvc Male Adapter Plastic Threaded - Fapt 50Mm , Upvc Male Adapter Plastic Threaded - Fapt 65Mm , Upvc Male Adapter Plastic Threaded - Fapt 80Mm , Upvc Male Adapter Plastic Threaded - Fapt 100Mm , Upvc Reducing Male Adapter Plastic Threaded- Mapt 20X15mm , Upvc Elbow 45 Degree (Sch 80) 15Mm , Upvc Elbow 45 Degree (Sch 80) 20Mm , Upvc Elbow 45 Degree (Sch 80) 25Mm , Upvc Elbow 45 Degree (Sch 80) 32Mm , Upvc Elbow 45 Degree (Sch 80) 40Mm , Upvc Elbow 45 Degree (Sch 80) 50Mm , Upvc Elbow 45 Degree (Sch 80) 65Mm , Upvc Elbow 45 Degree (Sch 80) 80Mm , Upvc Elbow 45 Degree (Sch 80) 100Mm , Upvc End Cap (Sch 80) 15Mm , Upvc End Cap (Sch 80) 20Mm , Upvc End Cap (Sch 80) 25Mm , Upvc End Cap (Sch 80) 32Mm , Upvc End Cap (Sch 80) 40Mm , Upvc End Cap (Sch 80) 50Mm , Upvc End Cap (Sch 80) 65Mm , Upvc End Cap (Sch 80) 80Mm , Upvc End Cap (Sch 80)100Mm , Upvc Reducer Coupler 20X15mm , Upvc Reducer Coupler 25X15mm , Upvc Reducer Coupler 25X20mm , Upvc Reducer Coupler 32X15mm , Upvc Reducer Coupler 32X20mm , Upvc Reducer Coupler 32X25mm , Upvc Reducer Coupler 40X15mm , Upvc Reducer Coupler 40X20mm , Upvc Reducer Coupler 40X25mm , Upvc Reducer Coupler 40X32mm , Upvc Reducer Coupler 50X15mm , Upvc Reducer Coupler 50X20mm , Upvc Reducer Coupler 50X25mm , Upvc Reducer Coupler 50X32mm , Upvc Reducer Coupler 50X40mm , Upvc Reducer Coupler 65X20mm , Upvc Reducer Coupler 65X25mm , Upvc Reducer Coupler 65X32mm , Upvc Reducer Coupler 65X40mm , Upvc Reducer Coupler 65X50mm , Upvc Reducer Coupler 80X50mm , Upvc Reducer Coupler 80X65mm , Upvc Reducer Tee 20X20x15mm , Upvc Reducer Tee 25X25x15mm , Upvc Reducer Tee 25X25x20mm , Upvc Reducer Tee 32X32x15mm , Upvc Reducer Tee 32X32x20mm , Upvc Reducer Tee 32X32x25mm , Upvc Reducer Tee 40X40x15mm , Upvc Reducer Tee 40X40x20mm , Upvc Reducer Tee 40X40x25mm , Upvc Reducer Tee 40X40x32mm , Upvc Reducer Tee 50X50x15mm , Upvc Reducer Tee 50X50x20mm , Upvc Reducer Tee 50X50x25mm , Upvc Reducer Tee 50X50x32mm , Upvc Reducer Tee 50X50x40mm , Upvc Reducer Tee 65X65x20mm , Upvc Reducer Tee 65X65x25mm , Upvc Reducer Tee 65X65x32mm , Upvc Reducer Tee 65X65x40mm , Upvc Reducer Tee 65X65x50mm , Upvc Reducer Tee 80X80x50mm , Upvc Reducer Tee 80X80x65mm , Upvc To Cpvc Converter- Coupler (Sch 80) 15Mm , Upvc To Cpvc Converter- Coupler (Sch 80) 20Mm , Upvc To Cpvc Converter- Coupler (Sch 80) 25Mm , Upvc To Cpvc Converter- Coupler (Sch 80) 32Mm , Upvc To Cpvc Converter- Coupler (Sch 80) 40Mm , Upvc To Cpvc Converter- Coupler (Sch 80) 50Mm , Upvc Bushing (Sch 80) 20X15mm , Upvc Bushing (Sch 80) 25X15mm , Upvc Bushing (Sch 80) 25X20mm , Upvc Bushing (Sch 80) 32X15mm , Upvc Bushing (Sch 80) 32X20mm , Upvc Bushing (Sch 80) 32X25mm , Upvc Bushing (Sch 80) 40X15mm , Upvc Bushing (Sch 80) 40X20mm , Upvc Bushing (Sch 80) 40X25mm , Upvc Bushing (Sch 80) 40X32mm , Upvc Bushing (Sch 80) 50X15mm , Upvc Bushing (Sch 80) 50X20mm , Upvc Bushing (Sch 80) 50X25mm , Upvc Bushing (Sch 80) 50X32mm , Upvc Bushing (Sch 80) 50X40mm , Upvc Bushing (Sch 80) 65X50mm Cts , Upvc Bushing (Sch 80) 65X50mm , Upvc Bushing (Sch 80) 80X50mm Cts , Upvc Bushing (Sch 80) 80X50mm , Upvc Bushing (Sch 80) 80X65mm , Upvc Bushing (Sch 80) 100X50mm Cts , Upvc Bushing (Sch 80) 100X50mm , Upvc Bushing (Sch 80) 100X65mm , Upvc Bushing (Sch 80) 100X80mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 25Mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 32Mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 40Mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 50Mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 65Mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 80Mm , Upvc Flange With Gasket - End Cap Open (Sch 80) 100Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 25Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 32Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 40Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 50Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 65Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 80Mm , Upvc Flange With Gasket - End Cap Closed (Sch 80) 100Mm , Upvc Brass Elbow 90 Degree 15X15mm , Upvc Brass Elbow 90 Degree 20X15mm , Upvc Brass Elbow 90 Degree 20X20mm , Upvc Brass Elbow 90 Degree 25X15mm , Upvc Brass Elbow 90 Degree 25X20mm , Upvc Brass Elbow 90 Degree 25X25mm , Upvc Brass Tee (Sch 80) 15X15x15mm , Upvc Brass Tee (Sch 80) 20X20x15mm , Upvc Brass Tee (Sch 80) 20X20x20mm , Upvc Brass Tee (Sch 80) 25X25x15mm , Upvc Brass Tee (Sch 80) 25X25x20mm , Upvc Brass Tee (Sch 80) 25X25x25mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 15Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 20Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 25Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 32Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 40Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 50Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 65Mm , Upvc Female Adapte Brass Threaded - Fabt (Sch 80) 80Mm , Upvc Reducing Female Adapter Brass Threaded - Fabt 20X15mm , Upvc Reducing Female Adapter Brass Threaded - Fabt 25X15mm , Upvc Reducing Female Adapter Brass Threaded - Fabt 25X20mm , Upvc Reducing Female Adapter Brass Threaded - Fabt 32X15mm , Upvc Reducing Female Adapter Brass Threaded - Fabt 32X20mm , Upvc Union- Fabt (Sch 80) 15Mm , Upvc Union- Fabt (Sch 80) 20Mm , Upvc Union- Fabt (Sch 80) 25Mm , Upvc Union- Fabt (Sch 80) 32Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 15Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 20Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 25Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 32Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 40Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 50Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 65Mm , Upvc Male Adapte Brass Threaded - Fabt (Sch 80) 80Mm , Upvc Reducing Male Adapter Brass Threaded- Mabt 20X15mm , Upvc Reducing Male Adapter Brass Threaded- Mabt 25X20mm , Upvc Union - Mabt (Sch 80) 15Mm , Upvc Union - Mabt (Sch 80) 20Mm , Upvc Union - Mabt (Sch 80) 25Mm , Upvc Union - Mabt (Sch 80) 32Mm , Upvc Short Bend (Sch 80) 15Mm , Upvc Short Bend (Sch 80) 20Mm , Upvc Short Bend (Sch 80) 25Mm , Upvc Short Bend (Sch 80) 32Mm , Upvc Short Bend (Sch 80) 40Mm , Upvc Short Bend (Sch 80) 50Mm , Upvc Short Bend (Sch 80) 65Mm , Upvc Short Bend (Sch 80) 80Mm , Upvc Short Bend (Sch 80) 100Mm , Upvc Short Bend (Sch 80) 150Mm , Upvc Sweep Bend-Socket At Both Sides (Sch 80) 15Mm , Upvc Sweep Bend-Socket At Both Sides (Sch 80) 20Mm , Upvc Sweep Bend-Socket At Both Sides (Sch 80) 25Mm , Upvc Sweep Bend-Socket At Both Sides (Sch 80) 32Mm , Upvc Stepover Bend (Sch 80) 15Mm , Upvc Stepover Bend (Sch 80) 20Mm , Upvc Stepover Bend (Sch 80) 25Mm , Upvc Stepover Bend (Sch 80) 32Mm , Upvc Stepover Bend (Sch 80) 40Mm , Upvc Stepover Bend (Sch 80) 50Mm , Upvc Reducer Elbow 90 Degree (Sch 80) 20X15mm , Upvc Reducer Elbow 90 Degree (Sch 80) 25X15mm , Upvc Reducer Elbow 90 Degree (Sch 80) 25X20mm , Upvc Cross Tee (Sch 80) 15Mm , Upvc Cross Tee (Sch 80) 20Mm , Upvc Cross Tee (Sch 80) 25Mm , Upvc Ball Valve (Sch 80) 15Mm , Upvc Ball Valve (Sch 80) 20Mm , Upvc Ball Valve (Sch 80) 25Mm , Upvc Ball Valve (Sch 80) 32Mm , Upvc Ball Valve (Sch 80) 40Mm , Upvc Ball Valve (Sch 80) 50Mm , Upvc Ball Valve With Brass Threaded (One Side) 20Mm , Upvc Ball Valve With Brass Threaded (One Side) 25Mm , Upvc Ball Valve With Brass Threaded (One Side) 32Mm , Upvc Ball Valve With Brass Threaded (Two Side) 20Mm , Upvc Ball Valve With Brass Threaded (Two Side) 25Mm , Upvc Ball Valve With Brass Threaded (Two Side) 32Mm , Upvc Ball Valve Handle 15Mm , Upvc Ball Valve Handle 20Mm , Upvc Ball Valve Handle 25Mm , Upvc Ball Valve Handle 32Mm , Upvc Ball Valve Handle 40Mm , Upvc Ball Valve Handle 50Mm , Upvc Non Return Valve 20Mm , Upvc Non Return Valve 25Mm , Upvc Gate Valve 15Mm , Upvc Gate Valve 20Mm , Upvc Gate Valve 25Mm , Upvc Butterfly Valve 40Mm , Upvc Butterfly Valve 50Mm , Upvc Butterfly Valve 65Mm , Upvc Butterfly Valve 80Mm , Upvc Butterfly Valve 100Mm , Upvc Butterfly Valve 150Mm , Upvc Ss Bolts For Butterfly Valves M12x125mm , Upvc Ss Bolts For Butterfly Valves M16x125mm , Upvc Ss Bolts For Butterfly Valves M16x150mm , Upvc Ss Bolts For Butterfly Valves M16x160mm , Upvc Elbow 90 Degree (Sch 40) 65Mm , Upvc Elbow 90 Degree (Sch 40) 80Mm , Upvc Elbow 90 Degree (Sch 40) 100Mm , Upvc Elbow 90 Degree (Sch 40) 150Mm , Upvc Tee (Sch 40) 65Mm , Upvc Tee (Sch 40) 80Mm , Upvc Tee (Sch 40) 100Mm , Upvc Tee (Sch 40) 150Mm , Upvc Coupler (Sch 40) 65Mm , Upvc Coupler (Sch 40) 80Mm , Upvc Coupler (Sch 40) 100Mm , Upvc Coupler (Sch 40) 150Mm , Upvc End Cap (Sch 40) 150Mm , Upvc Reducer Bushing (Sch 40) 150X50mm , Upvc Reducer Bushing (Sch 40) 150X65mm , Upvc Reducer Bushing (Sch 40) 150X80mm , Upvc Reducer Bushing (Sch 40) 150X100m , Upvc Reducer Coupler (Sch 40) 65X20mm , Upvc Reducer Coupler (Sch 40) 65X25mm , Upvc Reducer Coupler (Sch 40) 65X32mm , Upvc Reducer Coupler (Sch 40) 65X40mm , Upvc Reducer Coupler (Sch 40) 65X50mm , Upvc Reducer Coupler (Sch 40) 80X50mm , Upvc Reducer Coupler (Sch 40) 80X65mm , Upvc Reducer Tee (Sch 40) 65X65x20mm , Upvc Reducer Tee (Sch 40) 65X65x25mm , Upvc Reducer Tee (Sch 40) 65X65x32mm , Upvc Reducer Tee (Sch 40) 65X65x40mm , Upvc Reducer Tee (Sch 40) 65X65x50mm , Upvc Reducer Tee (Sch 40) 80X80x50mm , Upvc Reducer Tee (Sch 40) 80X80x65mm , Upvc Short Bend 9Sch 40) 15Mm , Upvc Short Bend 9Sch 40) 20Mm , Upvc Short Bend 9Sch 40) 25Mm , Upvc Short Bend 9Sch 40) 32Mm , Upvc Short Bend 9Sch 40) 40Mm , Upvc Short Bend 9Sch 40) 50Mm , Upvc Short Bend 9Sch 40) 65Mm , Upvc Short Bend 9Sch 40) 80Mm , Upvc Short Bend 9Sch 40) 100Mm , Upvc Flange With Gasket - End Cap Open(Sch 40) 150Mm , Upvc Flange With Gasket - End Cap Closed(Sch 40) 150Mm , Upvc Rubber Gasket For Flange 25Mm , Upvc Rubber Gasket For Flange 32Mm , Upvc Rubber Gasket For Flange 40Mm , Upvc Rubber Gasket For Flange 50Mm , Upvc Rubber Gasket For Flange 65Mm , Upvc Rubber Gasket For Flange 80Mm , Upvc Rubber Gasket For Flange 100Mm , Upvc Rubber Gasket For Flange 150Mm , Upvc Ss Clamp 15Mm , Upvc Ss Clamp 20Mm , Upvc Ss Clamp 25Mm , Upvc Ss Clamp 32Mm , Upvc Ss Clamp 40Mm , Upvc Ss Clamp 50Mm , Upvc Power Coated Metal Clamp 15Mm , Upvc Power Coated Metal Clamp 20Mm , Upvc Power Coated Metal Clamp 25Mm , Upvc Power Coated Metal Clamp 32Mm , Upvc Power Coated Metal Clamp 40Mm , Upvc Power Coated Metal Clamp 50Mm , Upvc Plastic Clamp 15Mm , Upvc Plastic Clamp 20Mm , Upvc Plastic Clamp 25Mm , Upvc Plastic Clamp 32Mm , Upvc Plastic Clamp 40Mm , Upvc Plastic Clamp 50Mm , Upvc Concealed Valve Quarter Turn-Mini Spindle With Plastic Knob 15Mm , Upvc Concealed Valve Quarter Turn-Mini Spindle With Plastic Knob 20Mm , Upvc Concealed Valve Quarter Turn-Mini Spindle With Plastic Knob 25Mm , Upvc Y- Strainer 25Mm , Upvc Y- Strainer 32Mm , Upvc Concealed Flush Valve 32X32mm , Upvc Concealed Flush Valve 40X32mm , Upvc Long Concealed Valve 15Mm Quarter Triangle , Upvc Long Concealed Valve 15Mm Quarter Square , Upvc Long Concealed Valve 15Mm Quarter Round , Upvc Long Concealed Valve 15Mm Quarter Plastic (Cp) , Upvc Long Concealed Valve 15Mm Full Triangle , Upvc Long Concealed Valve 15Mm Full Square , Upvc Long Concealed Valve 15Mm Full Round , Upvc Long Concealed Valve 15Mm Full Plastic (Cp) , Upvc Long Concealed Valve 20Mm Quarter Triangle , Upvc Long Concealed Valve 20Mm Quarter Square , Upvc Long Concealed Valve 20Mm Quarter Round , Upvc Long Concealed Valve 20Mm Quarter Plastic (Cp) , Upvc Long Concealed Valve 20Mm Full Triangle , Upvc Long Concealed Valve 20Mm Full Square , Upvc Long Concealed Valve 20Mm Full Round , Upvc Long Concealed Valve 20Mm Full Plastic (Cp) , Upvc Long Concealed Valve 25Mm Quarter Triangle , Upvc Long Concealed Valve 25Mm Quarter Square , Upvc Long Concealed Valve 25Mm Quarter Round , Upvc Long Concealed Valve 25Mm Quarter Plastic (Cp) , Upvc Long Concealed Valve 25Mm Full Triangle , Upvc Long Concealed Valve 25Mm Full Square , Upvc Long Concealed Valve 25Mm Full Round , Upvc Long Concealed Valve 25Mm Full Plastic (Cp) , Upvc Short Concealed Valve 15Mm Quarter Triangle , Upvc Short Concealed Valve 15Mm Quarter Square , Upvc Short Concealed Valve 15Mm Quarter Round , Upvc Short Concealed Valve 15Mm Quarter Plastic (Cp) , Upvc Short Concealed Valve 15Mm Full Triangle , Upvc Short Concealed Valve 15Mm Full Square , Upvc Short Concealed Valve 15Mm Full Round , Upvc Short Concealed Valve 15Mm Full Plastic (Cp) , Upvc Short Concealed Valve 20Mm Quarter Triangle , Upvc Short Concealed Valve 20Mm Quarter Square , Upvc Short Concealed Valve 20Mm Quarter Round , Upvc Short Concealed Valve 20Mm Quarter Plastic (Cp) , Upvc Short Concealed Valve 20Mm Full Triangle , Upvc Short Concealed Valve 20Mm Full Square , Upvc Short Concealed Valve 20Mm Full Round , Upvc Short Concealed Valve 20Mm Full Plastic (Cp) , Upvc Short Concealed Valve 25Mm Quarter Triangle , Upvc Short Concealed Valve 25Mm Quarter Square , Upvc Short Concealed Valve 25Mm Quarter Round , Upvc Short Concealed Valve 25Mm Quarter Plastic (Cp) , Upvc Short Concealed Valve 25Mm Full Triangle , Upvc Short Concealed Valve 25Mm Full Square , Upvc Short Concealed Valve 25Mm Full Round , Upvc Short Concealed Valve 25Mm Full Plastic (Cp) , Upvc Blue Medium Solvent Cement 29.5Ml Tube , Upvc Blue Medium Solvent Cement 59Ml Tube , Upvc Blue Medium Solvent Cement 118Ml Tin , Upvc Blue Medium Solvent Cement 237Ml Tin , Upvc Blue Medium Solvent Cement 473Ml Tin , Upvc Blue Medium Solvent Cement 946Ml Tin , Upvc Clear Medium Solvent Cement 118Ml Tin , Upvc Clear Medium Solvent Cement 237Ml Tin , Upvc Clear Medium Solvent Cement 473Ml Tin , Upvc Clear Medium Solvent Cement 946Ml Tin , Upvc Heavy Duty Grey Solvent Cement 118Ml Tin , Upvc Heavy Duty Grey Solvent Cement 237Ml Tin , Upvc Heavy Duty Grey Solvent Cement 473Ml Tin , Upvc Heavy Duty Grey Solvent Cement 946Ml Tin , Upvc Purple Primar Solvent Cement 237Ml Tin , Repair Patch 3X6inch , Repair Patch 6X9inch , Repair Patch 9X12inch , Uv Light , Body In Upvc 15Mm , Body In Upvc 20Mm , Body In Upvc 25Mm , Upvc Brass Mechanism Long, Qt 15Mm And 20Mm , Upvc Brass Mechanism Long, Ft 15Mm And 20Mm , Upvc Brass Mechanism Short, Qt 15Mm And 20Mm , Upvc Brass Mechanism Short, Ft 15Mm And 20Mm , Upvc Brass Mechanism Long, Qt 25Mm , Upvc Brass Mechanism Long, Ft 25Mm , Upvc Brass Mechanism Short, Qt 25Mm , Upvc Brass Mechanism Short, Ft 25Mm , Upvc Extension Tube Long , Upvc Extension Tube Short , Upvc Flange , Upvc Knobs Plastic , Upvc Knobs Round , Upvc Knobs Square , Upvc Knobs Triangle , Upvc Ceramic Disc , Allen Key (For Round Knob) , Grub Screw (For Round Knob) , Screw With Washer (For Triangle And Square Knob) , Red & Blue Buttons , Rubber Washer , Upvc Threaded End Plug , Fv Operating Mechanism , Fv Wall Flange With Washer , Ys Filter Mesh 25Mm , Ys Filter Mesh 32Mm , Ys Hex Nut 25Mm , Ys Hex Nut 32Mm , Upvc Pipes (Sch 40) 3Mtr. Length 15Mm , Upvc Pipes (Sch 40) 3Mtr. Length 20Mm , Upvc Pipes (Sch 40) 3Mtr. Length 25Mm , Upvc Pipes (Sch 40) 3Mtr. Length 32Mm , Upvc Pipes (Sch 40) 3Mtr. Length 40Mm , Upvc Pipes (Sch 40) 3Mtr. Length 50Mm , Upvc Pipes (Sch 80) 3Mtr. Length 15Mm , Upvc Pipes (Sch 80) 3Mtr. Length 20Mm , Upvc Pipes (Sch 80) 3Mtr. Length 25Mm , Upvc Pipes (Sch 80) 3Mtr. Length 32Mm , Upvc Pipes (Sch 80) 3Mtr. Length 40Mm , Upvc Pipes (Sch 80) 3Mtr. Length 50Mm , Room Freshner , Hand Wash 200 Ml( Dettol / Savlon) , Colin 500 Ml , Lizol500 Ml , Urinal Coupling , Soap Tray , Urinal Spraeder , Celling Broom , Detto/ Savlon Soap , Pvc Flexibalepipe 25 Mm , Acrylic Colour Emulsion Paint (Jonson / Nerolac / Berger / Asian) , Paint Brass Roller , Honda Brush Cutter Umk 435T U2nt , Tank Nipple 40 Mm Dia Pipe , Tank Nipple 50 Mm Dia Pipe , Ball Valve With Brass Treaded Two Side 32Mm Dia Pipe , Ball Valve With Brass Treaded Two Side 40Mm Dia Pipe , Ball Cock With Aluminum Rod & Pvc Ball 25 Mm Dia , Urinal Waste Pipe 24 Inch. , Besin Coupling , Aluminium Window Rubber , Measurement Tape 30M , Measurement Tape 15M , Measurement Tape Steel 3M , Measurement Tape Steel 5M , Curtain Wall Consealed Clamp , Cp 2 In 1 Pillar Cock (Jaguar Make) , Ag Green Pure Chill 120 Pss - Uv , Aluminium Door Lock , Nylon Rope , 1.25Mm Stainless Steel Curtain Rod 20 Long , 1.25Mm Brass Curtain Rod 20 Long , Precast Chequered Cement Tiles 22 Mm Thick , 18-22Mm Thick Kota Stone , Granite Slab More Than 4 Sqft , Marble Slab More Than 4 Sqft , Upvc U Clamp , (A) 15Mm , (B) 20Mm , (C) 25Mm , (D) 32Mm , (E) 40Mm , (F) 50Mm , Cpvc U Clamp , (A) 15Mm , (B) 20Mm , (C) 25Mm , (D) 32Mm , (E) 40Mm , (F) 50Mm , Aluminum Grill , Araldite - 180 Gm , Aluminum Paint , Chauk Powder , Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineerin-Charge. , Screws Of Size (5.5X 55 Mm) , Epdm Seal , Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+ 0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns , (A) Ridges Plain (500 - 600Mm) , (B) Flashings/ Aprons.( Upto 600 Mm) , (C) North Light Curves , (D) Barge Board (Upto 300 Mm) , (E) Crimp Curve , (F) Gutter .(600 Mm Over All Girth) , Flex Tape (Multipurpose Waterproof Flex Patch Bond Super Strong Instantly Stops Water Leakage Repair Duct Rubberized 10Cm Gorilla Tape) , Flexi Kwik , Aluminium A Interlock (Coloured) Best Quality- 16 Ft , Aluminium A Interlock (Natural) Best Quality- 16 Ft , Aluminium H-Section (Coloured) Best Quality- 16 Ft , Aluminium H-Section (Natural) Best Quality- 16 Ft , Aluminium A-Section (Coloured) Best Quality- 16 Ft , Aluminium A-Section (Natural) Best Quality- 16 Ft , Aluminium 2-Track Top (Coloured) Best Quality- 16 Ft , Aluminium 2-Track Top (Natural) Best Quality- 16 Ft , Aluminium 2-Track Bottom (Coloured) Best Quality- 16 Ft , Aluminium 2-Track Bottom (Natural) Best Quality- 16 Ft , Aluminium 3-Track Top (Coloured) Best Quality- 16 Ft , Aluminium 3-Track Top (Natural) Best Quality- 16 Ft , Aluminium 3-Track Bottom (Coloured) Best Quality- 16 Ft , Aluminium 3-Track Bottom (Natural) Best Quality- 16 Ft , Aluminium T-Clip (Coloured) Best Quality- 12 Ft , Aluminium T-Clip (Natural) Best Quality- 12 Ft , Aluminium Angle (Coloured) 12 Ft , Aluminium Angle (Natural) 12 Ft , Aluminium Rubber (Fixed Rubber) , Aluminium Door Far , Aluminium Door Middle (Coloured) Best Quality- 12 Ft , Aluminium Door Middle (Natural) Best Quality- 12 Ft , Aluminium Door Verticle (Coloured) Best Quality- 12 Ft , Aluminium Door Verticle (Natural) Best Quality- 12 Ft , Aluminium Door Top (Coloured) Best Quality- 12 Ft , Aluminium Door Top (Natural) Best Quality- 12 Ft , Aluminium G-Roller 4 Inch , Aluminium H-Handle 400Mm , Aluminium H-Handle 450Mm , Aluminium H-Handle 300Mm , Aluminium H-Handle 350Mm , Aluminium Drill Bit 9/64 (3.57 Mm) , Aluminium Drill Bit 1/8 (3.17 Mm) , Aluminium Drill Bit 7/64 (2.78 Mm) , Cutting Wheel , Open Level Hinge 12 Inch , Open Level Hinge 14 Inch , Open Level Hinge 10 Inch , Sand Paper 120 No , Sand Paper 100 No , Aqua Guard Diverter , Ac Ceiling Board (4X4)Ft , Aluminium Wall Conceal Best Quality , Aluminium Clamp For Curtain Rod Best Quality , Cp Health Faucet (Toilet Hand Shower Jet Sprey) , Terminator Liquid , Tiles Cleaner Liquid , Ss Screw 35X8 , Ss Screw 25X7 , Ss Screw 20X5 , Screw 19X8 (1000 Pcs) , Window Shutter (Sundi/ Gamari/ Segun) , Black Phenyl 450Ml , Cp Towel Ring (Solid/ Hollow) , Pvc Mosquito Net , Aluminium Ladder 8 Steps , Aluminium Ladder 5 Steps , Tiles Cutter Machine (Jk/Kpt/Bosch) , Tiles Cutter Blade (Taparia/ Bosch) , Granite Cutter Machine (Jk/ Kpt/ Bosch) , Ladies Urinal Pan( Hindware/ Parryware) , Particle Board , Aluminium P-Vot , Iron Z Section Pegstay , Brass Hinge 100Mm , Brass Hinge 75Mm , Iron Window Handle (Right & Left) , Joint Bolt For Cgi Sheet 25Mm , Joint Bolt For Cgi Sheet 32Mm , Best Quality White Polythene For Shuttering , Normal Quality Colour Polythene For Shuttering , Wooden Bit , Fevicol Sr 998 ( 5Ltr Tin) , Plastic Rope , Exterior Wall Putty (Asian/ Narolac/Jk/Berger) , Exterior Cement Primer , Ss Hinge 100Mm , Ss Hinge 75Mm , Aluminium Door Roller 100Mm , Aluminium Door Roller 150Mm , Aluminium Door Roller 125Mm , Cp Towel Rod 24 Inch , Cp Soap Tray , Brass Door Handle 100Mm , Brass Door Handle 150Mm , Brass Door Handle 200Mm , Ss Piano Type Hinge 6 Ft , Ss Pin (19 X 20) , Mp Lock 9350 (Cupboard Lock) Godrej Make , Cistern 10 Ltr With Push Button , Coconut Brush , Ss Screw 50 X 10 , Ss Screw 25 X 7 , Ss Screw 20 X 6 (Full Tread) , Ss Screw 20 X 7 (Full Tread) , Ss Screws 35 X 8 , Ss Screws 25 X 8 , Ssscrews 15 X 8 , Body Screw 35X25 , Body Screw 35X38 , Screw 19X17 (800 Pcs/Pkt) , Dustbin 40 Ltrs Swing Type , Dustbin 50 Ltrs Swing Type , Dustbin 200 Ltrs Wheel Type , Stainless Steel Friction Stay 10 , Stainless Steel Friction Stay 12 , Stainless Steel Friction Stay 19 , Gasket , Carbolic Acid , Big Size Pillar Cock (Royal Make) , Bullet Screw (Basin Fitting Screws) , Plank (For Fitting Of Pillar Cock & Bib Cock) , Pvc Solvent 500 Ml Pack , Chain Wrench 2 , Chain Wrench 3 , Chain Wrench 4 , Iron Hammer Drill Bit 4 , Iron Hammer Drill Bit 6 , Iron Hammer Drill Bit 8 , Iron Hammer Drill Bit 12 , Iron Hammer Drill Bit 16 , Iron Hammer Drill Bit 22 , Hardened Self Tapping Screw 8X13 , Hardened Self Tapping Screw 8X19 , Electric Geyser 10Ltrs ( Make -Crompton/Usha/V-Guard/ Havels , Electric Geyser 15Ltrs ( Make - Crompton/Usha/V-Guard/ Havels , Electric Geyser 20Ltrs ( Make -Crompton/Usha/V-Guard/ Havels , Electric Geyser 25Ltrs ( Make -Crompton/Usha/V-Guard/ Havels , Aluminium Open Level Hinge 8 Inch , Aluminium Open Level Hinge 10 Inch , Aluminium Open Level Hinge 12 Inch , Aluminium Open Level Hinge 14 Inch , Aluminium Open Level Hinge 16 Inch , Best Quality Hang Gloves , Best Quality 3 In 1 Sink Cock For Laboratory , Wood Cutter Machine , Best Quality Aluminium Spirit Level With Magnet 30Cm , Best Quality Aluminium Spirit Level With Magnet 45Cm , Best Quality Aluminium Spirit Level With Magnet 60Cm , Best Quality Aluminium Spirit Level With Magnet 100Cm , Wood Cutter Blade 100Mm , Best Quality White Polythene , Shuttering Cloth , Iron Paper , Cp Stop Cock (Royal Make) , Cp Angle Stop Cock (Royal Make) , Cp Bib Cock (Royal Make) , Cp Bib Cock 15Mm Big Size (Royal Make) , Big Size Pillar Cock (Jaguar Make) , Printer Cartridge , Pipe Cutter 42Mm , Best Quality Carpentary Tool Box (Big Size) , Best Quality Plumbing Tool Box (Big Size) , Aluminium Section , Aluminium Glazing Clip , Aluminium Glazing Clip Gusket , Damp Proof Putty , Dr. Fixit Chemical 302 , Dr. Fixit Chemical 301
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
7.
Law and Justice #10684159 Price Bid
Procurement Supply And Installation Of Kitchen Equipments And Appliances E-Tender For Procurement Supply And Installation Of Kitchen Equipments And Appliances For Gst And C Ex Canteen Of Chennai South Commissionerate Chennai -35. , Kitchen Equipments Burner , Stainless Steel Single Burner Ranger ( 304G ) Size:600 X 600 X 450Mm I ) Top Fabricated In Stainless Steel 304G 18Swg Thickness Sheet. With Ms 40X6mm Heavy Angle Support. Ii ) Side Panel Fabricated In Stainless Steel 304G, 20Swg Thickness Sheet With Air Ventilation Laser Holes. Iii ) Legs Made Out Of Stainless Steel 304G , 40 X 40Mm 16Swg Square Tube With Adjustable Nylon Bullet Legs Iv ) Cross Support Made Out Of Stainless Steel 304G, 16Swg 25 X 25Mm Square Tube. V ) Using G9 Burner With Unit And All Fitting Accessories. , Stainless Steel Double Burner ( 304G ) Size: 1219 X 600 X 450I ) Top Fabricated In Stainless Steel 304G 18Swg Thickness Sheet. With Ms 40X6mm Heavy Angle Support. Ii ) Side Panel Fabricated In Stainless Steel 304G, 20Swg Thickness Sheet With Air Ventilation Laser Holes. Iii ) Legs Made Out Of Stainless Steel 304G , 40 X 40Mm 16Swg Square Tube With Adjustable Nylon Bullet Legs Iv ) Cross Support Made Out Of Stainless Steel 304G, 16Swg 25 X 25Mm Square Tube. V ) Using G9 Burner With Unit And All Fitting Accessories. , Sink , Stainless Steel Single Sink ( 304G ) Size: 600 X 600 X 850 +150I ) Sink Top & Splash Back Fabricated In Stainless Steel 304G 18Swg Thickness Sheet. Ii ) 450 X 450 X 300 Tank Fabricated In Stainless Steel 304G16swg Thickness Sheet. Iii ) Legs Fabricated In Ss 304G 50Mm Dia Round Pipe With 2 Dia Adjustable Nylon Bullet Legs. Iv ) Cross Support Made Out Of Stainless Steel 304G16swg 425X25mm Square Tube. , Stainless Steel Triple Sink Unit ( 304G ) Size: 1800 X 600 X 850 +150I ) Sink Top & Splash Back Fabricated In Stainless Steel 304G 18Swg Thickness Sheet. Ii ) 450 X 450 X 300 Tank Fabricated In Stainless Steel 304G 16Swg Thickness Sheet. Iii ) Legs Fabricated In Stainless Steel 304G 50Mm Dia Round Pipe With 2 Dia Adjustable Nylon Bullet Legs. Iv ) Cross Support Made Out Of Stainless Steel 304G16swg 25X25mm Square Tube. , Rack , Pot Rack ( 304G ) 4 Tier Size: 900 X 600 X 1800 I ) Legs Made Out Of Stainless Steel 304G50mm Dia16swg Round Pipe With Adjustable Nylon Bush. Ii ) Leg Cross Support Made Out Of Stainless Steel 30430 X 30Mm Square Tube. Iii ) Cross Support Made Out Of Stainless Steel 304G16swg 20Mm Dia Round Tube , Storage Rack ( 304G ) Size: 600 X 600 X 1800 I ) Storage Shelves Fabricated In Stainless Steel 304G 20Swg Thickness Sheet, Under Stiffner Support. Ii ) Legs Fabricated In Stainless Steel 304G , 40 X 40Mm Square Tube With Adjustable Nylon Bullet Leg. , Work Table , I ) Work Table Top Fabricated In Stainless Steel 304G , 18Swg Thickness Sheet Under Stiffner Support Ii ) Middle And Bottom Shelves Fabricated In Stainless Steel 304G, 20Swg Thickness Sheet With Under Stiffner Support. Iii ) Legs Made Out Of Stainless Steel 304G, 50Mm Dia Round Tube With Adjustable Nylon Bullet Legs. , Freezers , I ) Freezers Inner Body And Tank Fabricated In Stainless Steel 304G , 22Swg Thickness Sheet. Ii ) Outer Body And Doors Fabricated In Stainless Steel 202G , 22Swg Thickness Sheet. Iii ) Inner And Outer Body Between Gap Filled With Puff Insulation. Iv ) Freezer Door Fabricated With Self Closing System. V ) Using Kirlosker Compressor For Freezing Unit. Vi ) Providing Temperature Digital Meter. , I ) Chiller Inner Body And Tank Fabricated In Stainless Steel 304G 22Swg Thickness Sheet. Ii ) Chiller Outer Body And Door Fabricated In Stainless Steel 202G 22Swg Thickness Sheet. Iii ) Chillers Inner And Outer Body Between Gap Filled With Puff Insulation Iv ) Providing Self-Closing Doors With Magnet V ) Using Kirlosker Compressor For Freezing Unit. Vi ) Providing Temperature Digital Meter. , Counter , Bainmarie Counter ( 304G ) 1 / 1 Gnpan - 5Nos Capacity [ Size: 1828 X 686 X 850 ] I ) Bainmarie Tank Fabricated In Stainless Steel 304G16swgthickness Sheet. Ii ) Side Covers And Panels Fabricated In Stainless Steel 304G20swg Thickness Sheet. Iii ) Providing 2 Nos3000watt Heater With Controller. Iv ) Legs Fabricated In Stainless Steel 304G50mm Dia16swg Thickness Pipe With Adjustable Nylon Bullet Legs. , Nutral Counter ( 304G ) Size: 1145 X 686 X 850 I ) Counter Top Fabricated In Stainless Steel 304G18swg Thickness Sheet With Under Stiffner Support. Ii ) Middle And Bottom Shelves Fabricated In Stainless Steel 304G20swg Thickness Sheet With Stiffner Support. Iii ) 3 Side Panels Fabricated In Stainless Steel 304G20swg Thickness Sheet. Iv ) Legs Fabricated In Stainless Steel 304G50mm Dia16swg Thickness Pipe With Adjustable Nylon Bullet Legs. , Shelves / Racks , Ms Slotted Angle Rack 5 Tier Size: 900 X 450 X 2100 I ) Shelves Fabricated In Ms 16Swg Sheet With Stiffner Support. Ii ) Legs Fabricated In Ms 14Swg Thickness Sheet With Lazer Holes. Iii ) Leg And Tray Connecting Clamps Fabricated In 14Swg Thickness Sheet. , Vegetable Rack ( 304G ) 4 Tier Size: 900 X 450 X 1800I ) Tray Fabricated In Stainless Steel 304G18swg Thickness Sheet With Laser Air Ventilation Holes Ii ) Legs Fabricated In Stainless Steel 304G 16Swg Thickness 50Mm Dia Round Tube With Adjustble Nylon Bullet Legs. , Onion Potato Bin ( 304G ) Size: 1219 X 600 X 900I ) Onion / Pototo Bin Base Fabricated In Stainless Steel 304G18swg Thickness Sheet Under Stiffner Support. Ii ) Post And Top Frame Fabricated In Stainless Steel 304G16swg40 X 40Mm Square Tube With Adjustable Nylon Bullet Legs. Iii ) Top Lid Fabricated In Ss 304G20swg Thickness Sheet. Iv ) Outer And Inner Partition Fabricated In Stainless Steel 304G6mm Round Rods. , Rice Pallet ( 304G ) Size: 762 X 762 X 150Mm I ) Pallet Top Frame And Inner Cross Pipe Fabricated In Stainless Steel 304G16swg40 X 40 Mm Square Tube With Adjustable Nylon Bullet Legs Ii ) Legs Connecting Cross Pipe Fabricated In Stainless Steel 304G 25X25mm Square Tube , Trolley , Service Trolley ( 304G ) Size: 18 X 30I ) Tray Fabricated In Stainless Steel 304G18swg Thickness Sheet. Ii ) Frame Fabricated In Stainless Steel 304G25mm Dia Round Tube With Base Wheel , Platform Trolley ( 304G ) Size: 36 X 24 X 34 I ) Base Fabricated In Stainless Steel 304G18swg Sheet. Ii ) Base Frame Fabricated In 304G40x40mm Square Tube Iii ) Handle Post And Handle Fabricated In Ss 304G16swg40x40mm Square Tube. Iv ) Providing Johnson Heavy Wheel , Exhaust System , I ) Hood: ( 42 Ft Approx ) A ) Hood Full Body Fabricated In Stainless Steel 202G 22Swg Thickness Sheet. B ) Filters And Greese Trap Fabricated In Stainless Steel 202G 22Swg Sheet. C ) Providing Light Box On The Top. Ii ) Stainless Steel Ducting ( 130 Sqft Approx ) A ) Duct Fully Fabricated In Stainless Steel 202G 22Swg Sheets With Support Materials. Iii ) Gi Ducting ( 130 Sqft Approx ) Iv ) Exhaust Motor7.5 Hp Motor 1 Nov ) Starter3 Phase Dol L&T Starter For Exhaust Motor1 No , Fabricated Air System I ) Stainless Steel 250 Sqft Approxa ) Fresh Air Ducting Fabricated In Stainless Steel Sheet 22Swg Thickness Sheet B ) Providing Adjustable Fresh Air Grills Ii ) Gi150sqft Approx A ) Fresh Air Ducting Fabricated In Gi Sheet 22Swg Thickness Sheet With Ms Supporting Angles. B ) Providing Adjustable Fresh Air Grills Iii ) Fresh Air Grill10 Nos Iv ) Fresh Air 2Hp Blower 2 Nos V ) 3 Phase Dol L&T Starter For Exhaust Motor1 No , Electrical Appliances , Preethi Mixi Xpro , Dough Kneeder ( 10 Kg Capacity ) Ponmani Motor , Commercial Tilting Grinder Consists Of Stone As Grinder Suguna Motor ( 7 Ltrs Capacity ) , Commercial Tilting Grinder Consists Of Stone As Grinder Suguna Motor ( 10 Ltrs Capacity ) , Potato Peeling Machine ( 10 Kg Capacity ) Ponmani Motor , Commercial Vegetable Cutting Machine ( Small ) , Sujatha Fruit Mixie , Bluestar Storage Water Coolers ( 150 Ltrs ) [ Pc15150-3T ] , Commercial Vegetable Cutting Machineblade , Coconut Scrapper Machine ( Ponmani Motor ) , Micro Oven ( 23 Litres ) , Electric Sandwich Griller ( Double ) , Tata C Class 1 / 2 Pipe With Support Clamp, Elbow, Tee Coupling And 3+3 Manifold System With Appropriate Commercial Fitting Like Vanaz 30Psi , Vanazf Valve , Double Bottle Connection, Copper, Control Valve And Pressure Gauge Meter ( 80 Rft Approx ) , Stainless Steel False Ceiling600sqft Approxproviding And Fixing Of Stainless Steel Grid System:Stainless Steel Grid Made Out Of Ss 202G 22Swg Thickness Sheet. Using Hot Dipped Galvanized Steel Section, Exposed Surface Chemically Cleaned Capping Prefinished In Backed Polyester Paint Wall Angle Of Size 19X19x3000mm Used In Periphery Of The Ceiling Fixed To The Wall / Partition / Rcc Coloumn / Band Walls With The Help Of Screws At 600Mm C / C. Main Runner Of Size 3600X15mmx38h Suspended At 1200Mm C / C By Using Regular Suspension Systems By Using 2.5Mm Dia G.I.Wire Hanger Securely Fixed To The Structure Soffit Of R.C.C Slab By Using 6Mm Fastener With J Bolt At Every 1200Mm ( Max ) And 600Mm Long Cross Tee Of Size 15Mmx38h To Be Interlocked Between In Main Runner At 600Mm And 1200Mm To Form Grid Size Of 1200X600mm And 600X600mm And Finaly Laying Of Ss Grid. , Vessels / Consumables , Aluminium Handi With Lid Spl ( 35Kg ) , Aluminium Handi With Lid Spl ( 25Kg ) , Aluminium Handi With Lid Spl ( 10Kg ) , Aluminium Handi With Lid Spl ( 5Kg ) , Aluminium Anna Koodai , Stainless Steel Square Tray , Stainless Steel Rice Colander , Gas Lighter , Knife , Stainless Steel Thuduppu , Stainless Steel Jarni , Stainless Steel Basin , Stainless Steel Bucket , Stainless Steel Jug , Stainless Steel Hot Box 10Ltr , Stainless Steel Drum , Stainless Steel Tope Set , Stainless Steel Karandi Long No:5 , Stainless Steel Sauce Pan , Mskadai 24 , Ms Knife , Stainless Steel Lemon Squcer , Stainless Steel Veg Grater , Stainless Steel Anda , Ms Kadai 30 , Ms Thuduppu , Ms Oil Jarni , Ms Oil Stainer , Ms Ural , Chopping Board ( 12X18x1 ) , Stainless Steel Masala Box ( 12 Com ) ( 1 / 2Kg Capacity ) , Stainless Steel Water Tumbler , Stainless Steel Tea Tumbler , Pradeep Cookpot Half Size ( 93Ltr ) ( 60Cm ) , Pradeep Cookpot Half Size ( 71Ltr ) ( 55Cm ) , Pradeep Cookpot Full Size ( 170Ltr ) ( 60Cm ) , Pradeep Cookpot Full Size ( 130Ltr ) ( 55Cm ) , Pradeep Cookpot Full Size ( 98Ltr ) ( 50Cm ) , Plastic Action Drum With Lid [ 80 Ltrs ] , Plastic Action Drum With Lid [ 60 Ltrs ] , Stainless Steel Sqr Tin With Lid [ 10 Kg Capacity ] , Stainless Steel Sqr Tin With Lid [ 5 Kg Capacity ] , Stainless Steel Sqr Tin With Lid [ 3 Kg Capacity ] , Plastic Round Container ( 1 Kg Capacity ) , Plastic Round Container ( 2 Kg Capacity ) , Aluminium Tray , Aluminium Sauce Pan , Aluminium Holes Anna Koodai , Nilkamal Pallet , Nilkamal Crate ( Jbc64320 ) , United Ap Spoon , Ms Oil Dosa ( Big ) Karandi , Ms Chinese Kadai , Stainless Steel Chinese Karandi ( No: 6 ) , Stainless Steel Net Stainer ( No: 12 ) , Ms Dosa Karandi ( No: 2 ) , Wood Roller , Wood Manai , Stainless Steel Tea Stainer ( No: 7 ) , Stainless Steel Juice Stainer ( No: 7 ) , Stainless Steel China Plate For Tumbler Storage In Table , Nilkamal Dustbin With Dome Lid ( 80 Ltrs ) , Aluminium Rice Colander , Stainless Steel Anda With Lid & Handle ( 4 Pcs ) , Stainless Steel Kattori ( Size: 4 1 / 2 ) , Stainless Steel Coffee Dabara With Tumbler Set , Stainless Steel Breakfast Plate , Stainless Steel Lunch Plate , Stainless Steel Snacks Plate
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
8.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
9.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
10.
Health and Family Welfare #10551406 Price Bid
Tender For Remaining Electrical Work Phc Building At Sadri District Jodhpur - 1 (Integrated Elect. BSR 2021) Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18SWGHotDippedGalvanized ModularBox withearth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pinceilingrose/lampHolder/3pinconnector,screwsetc, making connections,all as per pre approved by Engineer in charge, testingetc.completeasrequired. Forspecificationofcopper Conductor,Phenolic Laminated sheets & Electrical/ Wiring accessories referChapterE-04,E-05&E -07 .For additional technicalparametersofproducts/ work, refer Annexure A attached with this BSR. 2 Medium point (up to 6 mtr.) 3 Long point(up to 10 mtr..) 4 WiringoftwincontrollightpointasperPWDspecificationfor electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulatedunsheathedflexiblecopperconductor 1.1kVgrade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,2 nos. 18 SWG Hot Dipped Galvanized Modular Box with earth terminal ,2Nos6AtwowayModularswitch,3pinceilingrose/lamp holder/ 3pinconnector,Modularfaceplatewith gridplate, screws etc,all as per pre approved by Engineer in charge,making connections,testingetc. completeasrequired. Forspecification ofcopper Conductor, PhenolicLaminated sheets&Electrical/ Wiringaccessories referChapterE-04,E-05&E-07. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Medium point (up to 6 mtr.) 5 Long point(up to 10 mtr..) 6 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification forelectricalWorkswithISI marked1.5 sq.mmnominalsizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and1.5 sq.mmnominalsize FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit&itsallaccessories(J.B.,Bendsetc.),roundtiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, makingconnections,testingetc.completeasrequired. For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work refer Annexure A attached with this BSR . On board 7 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1 x 1.5 sq.mm 8 3x 1.5 sq.mm 9 2 x 2.5 sq. mm. + 1x1.5sqmm 10 1 x 4.0 sq.mm 11 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 12 1 x 6.0 sq.mm 13 4 x 6.0 sq.mm 14 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 16.0 sq.mm 17 S&Ffollowingsizes(dia.)ofISImarkedMMS(IS:9537P-III) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptancetests reports byanyNABLaccreditedlabfortheconduitshallbesubmitted before execution & All as per pre approved by Engineer in charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . MMS ( IS:9537 P - III ) PVC conduit 18 25 mm 19 32 mm 20 Supplying andLaying ISImarkedP.V.C. insulated submersible cable as per PWD specification for electrical Works confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type Aor C,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6.0 Sq.mm 3 core flat / Round 21 Providing & Fixing of phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 75 mm dia 22 P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single pole MCB6 A to 32 A rating 24 Double pole MCB 40 A rating 25 Four pole MCB 50-63 A rating 26 Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . IP-43 Double door (single phase) 27 16 Way (16 O/G +2 I/C) 28 IP-43 Double door (Three phase) 6 Way ( 18 O/G + 8 I/C ) 29 Providing & Fixing of metal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base insheet steel( CRCA ) powed coated enclosure as per PWD specification for electrical Works conforming to Is 8623 & IEC 61439-3 (without MCB) including , all as per pre approved by Engineer in charge,making connections,, testing etc.as required .OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 A Double Pole(single phase Three pin ) 30 Providing & Fixing of recessed/surface mounting heavy duty sheet steel not less then 1.2 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . For TPN 6 way DB 31 Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Providing & Fixing of ISI marked (IS:2268-1994) gong bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 33 Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 5 step fan regulator 100 watt 2 Module 34 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35 SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:- (a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure (b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. (d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 36 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 37 Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type 38 Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field- programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Digital type Confirming to IEC 62053-21 Below 500 A 39 Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Red/yellow/Green colour 40 Blue / white Colour 41 Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . C T Class 1, Ratio upto 150/5, Burden 5 VA 42 Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range - 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 43 Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV 44 SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 45 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 46 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Open execution type 160 A 47 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 %& as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Armoured Cable 6.0 Sq. mm 2 core 48 10.0 Sq. mm 2 core 49 35.0 Sq. mm 4 core 50 Providing & laying of Double wall corrugated pipe confirming to IS : 14930 P - 1 & 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required( Excavation of Earth to be paid Extra as required. ) of following Outer Dia. / Inner dia as per IS:4984:1995. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 110 / 95 mm 51 SITC of chemical Gel earthing system of Dual Pipe Technology made of with B Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second. (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts. (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell GI pipe 2000 mm long, 80 / 50 mm, Terminal 50mm x 6 mm GI Strip 52 Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 25mm x 3mm Alum. Strip 53 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 100 mm dia. 54 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start,aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to al lthe performance requirements laid down in IS 374:2019 inluding all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 55 Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR300 mm sweep(900/1400 RPM) 56 Making of hole in wall (brick/stone) of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: Up to 457 mm size 57 P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Up to 380 mm size 58 Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 15 Ltr. 59 25 Ltr. 60 SITC of ISO Certified company made MNRE approved & confirming to IS:12933 P-1,2,3 & 5 Flat Plate Collector type solar hot water system with collector, insulated stainless steel (SS grade:304) storage tank with electrical back up with Portable Residual Current Device ( PRCD ) facility form OEM , CRCA Powder coated /MS stand for Collector & Tank etc. as required. of following capacity complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 100 litre/ day 61 Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Suitable for 4 LED Tube shape fixture 1 X 18/20 W 62 Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. Surface Mounting LED Downlight 18/20W 63 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attached with this BSR. Suspended Mounting/Surface Mounting 36W LED light fixture 2x2 with acrylic / prismatic front cover. 64 Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stabilization report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumenmaintained,colorRendering Index>70 andCCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . LED Street Light fixture 70 Watt 65 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fasteners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 66 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest amendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, separated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 67 Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessary connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, Un-sheilded Information Outlet 68 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single Aperture 69 Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 U wall mounted Enclosure 70 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 12 Ports 71 Supply , Installation, Testing and Comissioning of Unmanaged Switch Plug-and-play easy setup with no configuration or no software needed, following Port fast ethernet - 8 10/100/1000 MBPS gigabit auto-negotiation RJ45 ports, IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 24 Port 72 Supply Installationtesting&CommissioningofISOcertified manufacturer made Monoblock motor pump set ISI marked (IS:9079- 2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2- 1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, . Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. Appropriate type test certificate / OEM test report shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM 73 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 74 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest amendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord 1 Mtr 75 2 Mtr 76 Supply , Installation, Testing and Commissioning of ISO certified company made Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year OEM warranty both compressor and PCB. NABL accelerated as per IS/ISO/IEC 17025 standards / CPRI/ ERDA lab testing reports as per IS 1391(Part-2) 2018 with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Non Invertor Type 1.5 TR with 3 star rating of BEE (ISEER not less then 3.5 ) 77 Providing & Fixing of ISI marked (IS : 15778 - 2007) Rigid CPVC drain water piping 6 kg/ cm2 with fittings like elbow, soket, Tee etc & support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20 mm dia 78 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp plug top making connection etc complete in all respect. NABL accelerated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kVA 79 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accommodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 50 mm dia per running inch length 80 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 81 Supply , Installation, Testing and Commissioning of ISO certified company made self contained drinking water coolar with BEE Rated energy efficient hermetic sealed type compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz ac supply,Full stainless steel (S304)body and tank , stainless steel water tray, minimum two nos faucets and suitable drainage system complete in all respect with 300mm height MS fabricated and painted plateform. complete in all respect of the following capacity. NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 82 Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 kg 83 Providing & Fixing in position frame made out of M.S. angle (riveted or welded) as per IS: 2062-2011 finished with two coats of red oxide and two coats of enamel paint including cutting, welding, holes etc. of following sizes as required. All drawing as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 35mm x 35mm x 5mm 84 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 A one way switch 85 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR6 A3/5 pin shuttered socket
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
11.
Health and Family Welfare #10551402 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Setrawa Block Dechu District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
12.
Public Administrative Department #10545789 Price Bid
Work-01 , Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal / Circular Cross-Sections Designed To Withstand The Maximum Wind Speed As Per Is 875, The Pole Shaft Shall Be Made From Sheet Steel (Ht Steel Conforming To Grade S355jo) And Confirming To Bsen 10025 And Shall Be Continuously Tapered With Single Longitudinal Welding. There Shall Not Be Any Circumferential Welding. The Welding Of Pole Shaft Shall Be Done By Submerged Arc Welding (Saw) Process. Pole Shafts Shall Be Provided With The Rigid Flange Plate Of Suitable Thickness (Fe 410 Conforming To Is 226 / Is 2062) With Provision For Fixing 4 No. Foundation Bolts, This Base Plate Shall Be Fillet Welded To The Pole Shaft At Two Locations I.E. From Inside And Outside.The Octagonal Poles Shall Have Lockable Door Of Approximate 500 Mm Length At The Elevation Of 500 Mm From The Base Plate With Bakelite Sheet Having 6A Sp Mcb And 16 Sqmm Stud Type Connector ( 4 Nos) Inside The Pole At Door Opening For Cable Connection Of Following Length And Dimension As Per Table P-01 With Base Plate And Foundation Bolt On The Existing Cement Concrete Foundation.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 9 Mtr. , Supply And Fixing Of Pole Oem Fabricated Hot Dipped Galvanised M.S. Overhang (48.3 X 3.25 Mm) With Cap (400 X 88.9 / 114.3 X 3.25 Mm) Over The Existing Poles. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Single Arm Overhang , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) <10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current <750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 18750 Lm , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.16 Sq. Mm 4 Core , 25 Sq. Mm 3.5 Core , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity >99.7 %, Round / Flat Strip Armouring, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr6 Sq. Mm 3 Core , Plate Earthing As Per Is:3043 With Copper Earth Plate Of Purity >95% Of Size 600Mm X 600Mm X 3.0Mm By Embodying 3 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Surface By Means Of Earth Strip Dmc Insulator Including Riveting/ Soldering/ Welding, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass (For Cu Strip) / Gi (For Gi Strip) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 20Mm X 3Mm Copper Strip , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsrsingle Pole Mcb (With B/C Curve Tripping Characteristics) 40 A Rating , Providing And Laying Rcc Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Table P-4 With Following Procedure & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Pole Foundation For Octagonal Pole From 7 Mtr. To 9 Mtr. , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .90 Mm , Supply & Laying Following Size B Class , G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc. For Laying Earth Conductor/ Strip / Cable In Ground/ Surface/ Recess As Required. All As Per Pre Approved By Engineer In-Charge. (Earth Excavation Will Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annex Ure A Attached With This Bsr . 80 Mm Dia. , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Labour Charges For Trimming Of Tree Branches/Plants And Prepairing Route Approaches For Electric Proposed Line Complete With Prior Permission Of Local Authority In Writing , Taking Proper Shutdown From Discom Office And Inform To Discom After Complete The Work. , Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:-(A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided(B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire.[C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra )(F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra )(H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .3 Pole Power Contactors With Following Ac 3 Rating 250 Amp , Sitc Of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr4 Pole Mccb With Microprocessor Based Release With Adjustable O/L & S/C Setting With Inbuilt Instantaneous And Ground Fault Protection, 250 Amp , 50 Ka , Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Red/Yellow/Green Colour , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day Reserve (Analog Type ) , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsrsingle Pole Mcb (With B/C Curve Tripping Characteristics) 100 A Rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
13.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
14.
Health and Family Welfare #10363172 Price Bid
Tender For Electrification Work In Phc Building At Khetasar Block Osian District Jodhpur; 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
15.
Housing Urban and Rular Development #10350279 Price Bid
Tender For Construction Of Labour Ward In Hostpitalgangashahar - Bikaner ( Electricalwork ) Construction Of Labour Ward In Hostpital Gangashahar - Bikaner ( Electricalwork ) - 1 Note:-Please read Annexure A for each Items if not uploaded in e tender, see on pwdraj website.Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 On board 7 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories with own OEM CM/L No. as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 8 20 mm 9 25 mm 10 32 mm 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 1 x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 1 x 6.0 sq.mm 16 4 x 16.0 sq.mm 17 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 18 Single pole MCB (With B/C curve tripping Characteristics) 19 6 A to 32 A rating 20 Four pole MCB (With B/C curve tripping Characteristics) 21 50/63 A rating 22 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 Metal door (Three phase) IK-09 and IP-43with Metal end box 24 6 Way 25 Providing & Fixing ofISI marked (IS:1293) 16 ampunbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 26 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 27 25 Amp.2 Moduleswitch With LedIndicator 28 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 25 Amp. 2 Module Socket 30 Providing & Fixing of modular type 100/120W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 5 step fan regulator 2 Module 32 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 33 Blanking plate 34 Modular MCB 6 A to 32 ASP 35 Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 36 1/2 Module 37 3 Module 38 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 1-2 Module 40 3 Module 41 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 42 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 43 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 44 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 45 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 46 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 47 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 48 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 49 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 50 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 51 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade 54 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Blue / white Colour 56 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 4 pole MCCB With Thermal Magnetic release 58 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 59 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 60 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 61 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 62 Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosuresuitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3. powder painted complete with din railmaking internal DBterminations,detachable gland plate, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable 64 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 Open execution type 66 400 A 67 Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity, bus barfixed on porcelain/DMC insulators at approved spacingincluding making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 450 mm long , 4 strip 69 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 95.0 Sq. mm 71 3.5 core 72 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 73 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 74 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 75 50.0 Sq.mm 76 95.0 Sq.mm 77 Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 300mm x 50mm x 1.6mm 79 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 63mm 81 Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 82 17.2 mm thick and 3 Mtr. Long 83 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 84 32mm x6mm G.I. ( Hot Dipped) Strip 85 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 86 10 SWG G.I. ( Hot Dipped) Wire 87 Supply & Fixing of phenolic laminated boardof 6.4 mm thick forfresh air fan/exhaust fan up to size of 300 mm onexisting window frame including cost of board, cutting of hole , Nut bolts etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 89 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 90 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side complete with minimum weight of 750 gm. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 300 mm sweep 94 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 Up to 380 mm size 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 25 Ltr. 99 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 100 Recessed Mounting 101 Minimum lumen output 1300 lm 12 W 102 Minimum lumen output 1950 lm 18 W 103 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 104 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Recessed Mounting 106 Minimum lumen output 4200 lm 36W 107 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 108 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
16.
Health and Family Welfare #10276803 Price Bid
Tender For Electrification Work At Construction Of Chc Building At Jhinjhiyali District Jaisalmer - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 20 mm 13 25 mm 14 32 mm 15 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 16 1 x 1.5 sq.mm 17 2 x 2.5 sq. mm. + 1x1.5sqmm 18 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 19 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 20 1 x 4.0 sq.mm 21 4 x 6.0 sq.mm 22 4 x 10.0 sq.mm 23 Providing & Fixing of ISI marked surface type buzzer (IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 24 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25 75 mm dia 26 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 27 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 5 step fan regulator 2 Module 360 dgree rotating 29 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 30 Blanking plate 31 25 Amp. 2 Module Motor Starter with on / off Push button 32 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 33 25 Amp. 2 Module Socket 34 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 36 Up to 380 mm size 37 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 38 3 pair 39 5 pair 40 50 pair 41 20 pair 42 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 43 20 Pairs 44 50 Pairs 45 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 46 1.2 mm thickM. S. Sheet boxes 47 175mm x 100mm x 60mm 48 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 49 3.0 mm thick 50 Providing & Fixing of flush typenon modular single line telephone jackmade out fromindustrial grade Polycarbonate or fire resistant ABS material, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Cat 6, Un-sheilded Information Outlet 54 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Single Aperture 56 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 Single pole MCB (With B/C curve tripping Characteristics) 58 6 A to 32 A rating 59 Triple pole MCB(With B/C curve trippingCharacteristics) 60 6 A to 32 A rating 61 50/63 A rating 62 Four pole MCB (With B/C curve tripping Characteristics) 63 6 A to 32 A rating 64 50/63 A rating 65 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 66 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 67 6Way(Incomer 8,Sub Incomer2+2+2) 68 8Way(Incomer 8,Sub Incomer2+2+2) 69 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 Two pole 100/300mA sensitivity 71 63 A rating 72 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 73 Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box 74 6 Way 75 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 76 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 77 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 78 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 79 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 80 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 81 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 17.2 mm thick and 3 Mtr. Long 83 Plate Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 25mm x 3mm copper strip 86 25mm x 3mm G.I. ( Hot Dipped) Strip 87 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 89 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 90 300 mm sweep(900/1400 RPM) 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 Wall mounting type with Adjustable Vertical Angle 95 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 97 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 98 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 99 Surface Moutning 100 Minimum lumen output 3600 lm 101 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 102 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 103 Surface Mounting (with extruded alumn. Housing ) 104 Minimum lumen output 1950 lm 105 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 106 6.0 Sq. mm 107 4 core 108 10.0 Sq. mm 109 4 core 110 16.0 Sq. mm 111 4 core 112 25.0 Sq. mm 113 3.5 core 114 50.0 Sq. mm 115 3.5 core 116 70.0 Sq. mm 117 3.5 core 118 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 4 x 6.0 sq.mm 120 4 x 10.0 sq.mm 121 4 x 16.0 sq.mm 122 3.5 x 70.0 sq.mm 123 3.5 x 50.0 sq.mm 124 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 125 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 126 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 127 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 128 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 129 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 130 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 131 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 132 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 133 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 134 Electrolytic grade Aluminium bus bar 6010 grade 135 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 Three phase Ammeterwith Inbuilt Selector Switch 137 Three phase Voltmeter with Inbuilt Selector Switch 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio upto 150/5, Burden 5 VA 141 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 142 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 143 Red/yellow/Green colour 144 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 146 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 148 Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phasesensing compensationpower factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 149 6 to 8 stage 150 Providing & Fixing of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 151 up to 6 KVAR 152 10 KVAR 153 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 154 3 pole MCCB With Thermal Magnetic release 155 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 156 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 157 4 pole MCCB With Thermal Magnetic release 158 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 159 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 160 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 161 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 162 LED Street Light fixture with Minimum lumen output 3700 lm 163 LED Street Light fixture with Minimum lumen output 8700 lm 164 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 165 SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be ofcarbon + S.S.The stator body of single phase pumpshall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 166 1.5 HP, 1-Ø, (18 -26) Mtr, (126 - 78) LPM 167 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 168 B class 50mm dia 169 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 170 For Three phase Submersible / Mono block pump 171 3.0 HP to 5.0 HP ( Star / Delta starter ) 172 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 173 6.0 Sq.mm 3 core flat / Round 174 Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 175 150mm x 50mm x 1.6mm 176 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 177 50mm x 50mm x 6mm 178 35mm x 35mm x 5mm 179 Providing & Fixing ofCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 10 AMP 181 32 AMP 182 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Open execution type 184 125 A 185 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 186 Poles with Octagonal Cross Section 187 7 Mtr. 188 Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 189 160 mm X 225 mm X 100 mm 190 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 191 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 192 1/2 Module 193 3 Module 194 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 1-2 Module 196 3 Module 197 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 15 Ltr. 199 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 Single arm overhang 201 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I 202 A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . 203 B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled 204 C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. 205 D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 206 E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA. 207 F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 208 G) Servicing Contract of DG Set from OEMs Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. 209 H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. 210 I) DG set will be offered for Inspection and Testing at Manufacturers Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 211 50 KVA at 0.8 pf 415V 50Hz 3-ǿ 212 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 50 to 82.5 KVA 214 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 215 8 SWG copper Wire 216 Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length)includingcutting,welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect.(Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 217 125 mm dia 218 P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 219 Supply, installation, testing & commissioning of following size & Material air termination rods confirming to IEC/EN 62561 with suitable OEM recommendedmounting arrangement on parapet wall all as per standard , complete as required. the test report accredited by third party accreditation body like VDE/ ILAC/ DAkkS/ UL/ NABL is to be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 220 1500 mm long, 10 mm Dia. Aluminium / AlMgSi 221 Supply & Fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 10 / 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1, tested to carry from 100KA (10/350μs) lightning current the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 222 Supply and Fixing of stainless steel clamp for holding 8mm dia. conductor on Parapet Wall / Side Fl 20 mm, Height- 20 mm & Complied as per Standard EN 62561-4. With accessories SS Screw and Gitty etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 223 Supply & LayingofAluminum / SS / AlMgSi Round Conductor confirming to IEC/EN 62561 etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. ( Supporting Clamps to be paid Extra )All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 224 8 mm Dia. Aluminium conductor 225 Supply and Fixing of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor with25 mm x 6 mm GI strip etc. as required. the test report accredited by third party accreditation body likeVDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 226 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 227 24 Ports 228 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 230 1 Mtr 231 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 232 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 233 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 234 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 235 1.5 TR ISEER not less then 3.8 236 2.0 TR ISEER not less then 3.8 237 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 238 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 4 kVA 240 5 kVA 241 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 242 25 mm 243 SITC of Interconnecting refrigerantcopper pipe forsplit/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizesas per OEM requirement & specifications including class O Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 244 Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existingsurface or recessed PVC/ MS conduit/casing capping/ Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 245 Armoured 246 4 core x 2.5 Sq.mm 247 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 249 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 250 4 kg 251 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 252 Capacity 4.5 Kg.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
17.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
18.
Public Administrative Department #10252967 Price Bid
Tender For Work Of Installing Octagonal Poles And Led Lights At Various Places In Ward No. 01 To 25 In The Municipality Area; 1 Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in allrespect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. (See Table P -01 for specs.) 7 Mtr. 2 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Single arm overhang 3 Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Double arm overhang 4 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured/ Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Armoured Cable 16.0 Sq. mm 2 core 5 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured/ Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures. (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. Armoured Cable 16.0 Sq. mm 3.5 core 6 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge, making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3 x 4 sq. mm. 7 SITC of chemical Gel earthing system of Dual Pipe Technology made of with B Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :- (a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . (b) To ensure the moisture content and electrical conductivity, 25 kgfor 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for lowresistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043- 1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts (c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . GI pipe 3000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip 8 Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 25mm x 5mm copper strip 9 Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/ToughenedGlass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I)<10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures WordMark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. LED Street Light fixture 90 Watt 10 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 11 Providing, lowering, laying & jointing MDPE/ HDPE pipes (Class-PE 80) PN 12.5 composite pipes for extra length for house service connections as per drawing and specifications complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. With HDPE pipe 32 mm dia service pipe 12 Providing & Fixing of ISO certified company made TP&N 415 V side handle operated double break fuse switch unit in sheet steel enclosure as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 (W/O HBC fuses) including making connections with suitable lugs, testing etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR. 63 A rating 13 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 3 pole Power contactors with following AC 3 Rating 80 Amp 14 Providing & Fixing of Powder coated CRCA sheet on existing angle iron frame by means of nuts and bolts and making holes , etc. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with thisBSR . 2.5 mm thick 15 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer AnnexureA attached with this BSR . Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade 16 P &F in position frame made out of M.S. angle (riveted or welded) finished with two coat of red oxide and enamel paint including cutting, welding, holes etc. of following sizes as required. 40mm X 40mm X 5mm 17 Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Four pole MCB 80 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
19.
Health and Family Welfare #10187107 Price Bid
Tender For Electrification Work In Phc Building At Moriya District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
20.
Health and Family Welfare #10187103 Price Bid
Tender For Electrification Work In Phc Building At Bhudkiya District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
21.
Health and Family Welfare #10187085 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Manihari Block Pali District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
22.
Health and Family Welfare #10187079 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Sadri Block Desuri District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
23.
Health and Family Welfare #10187077 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Takhatgarh Block Sumerpur District Pali - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
24.
Health and Family Welfare #10187074 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Dhawa, Block Dhawa District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
25.
Health and Family Welfare #10187067 Price Bid
Tender For Electrification Work In Bphu And Bphl At Chc Bhaniyana Block Bhaniyana District Jaisalmer - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 11 20 mm 12 25 mm 13 32 mm 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 2 x 2.5 sq. mm. + 1x1.5sqmm 16 1 x 4.0 sq.mm 17 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 18 4 x 6.0 sq.mm 19 4 x 10.0 sq.mm 20 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 21 1.2 mm thickG Iboxes 22 100mm x 100mm x 60mm 23 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 3.0 mm thick 25 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 26 75 mm dia 27 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 Single pole MCB (With B/C curve tripping Characteristics) 30 6 A to 32 A rating 31 Four pole MCB (With B/C curve tripping Characteristics) 32 50/63 A rating 33 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 34 Metal door (Three phase) IK-09 and IP-43with Metal end box 35 8 Way 36 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 37 Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box 38 4 Way 39 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 IP -67 Surface/Wall mounted socket 43 32 A 3 pin(2P+E) 44 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 45 5 step fan regulator 2 Module 360 dgree rotating 46 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 47 4 pole MCCB With Thermal Magnetic release 48 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 49 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 50.0 Sq. mm 51 3.5 core 52 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 53 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 54 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 55 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 56 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 57 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 58 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 59 17.2 mm thick and 3 Mtr. Long 60 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 25mm x 3mm Alum. Strip 62 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 64 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 300 mm sweep(900/1400 RPM) 66 380 mm sweep(900/1400 RPM) 67 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 Up to 380 mm size 69 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 71 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 72 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 Surface Mounting (with extruded alumn. Housing ) 74 Minimum lumen output 2400 lm 75 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 LED Street Light fixture with Minimum lumen output 8700 lm 77 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 32 mm Dia. 79 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Cat 6, Un-sheilded Information Outlet 82 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Single Aperture 84 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 86 2 Mtr 87 Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic,should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc., as per latest ammendments of TIA/EIA 569Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 12 Ports 90 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.5 TR ISEER not less then 3.8 93 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kVA 95 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 96 100 mm dia per running inch length 97 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 20 mm 99 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 101 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
26.
Power #10181686 Price Bid
Tender For Development Of 11Th Floor In Modern Style Cubical Office With All Civil, Electrical, Fire, Ac Work, 1 Laying And Jointing Pvc Pipe. Heading 2 Providing Good Quality Markeen For Proper Bindig File And Document As Per Direction Of E-I-C. 3 Providing Labour For Proper Arrangement Of Binding File And Shifting Files And Furniture From One Place To Another Place With Required Labor, T&P For Proper Completion Of Work. 4 Dismantling Doors Or Window Leaves Including Stacking Ofmaterials As Directed By The Engineer I / C Within A Dist. 60 M. 5 Dismantaling Doors And Windowschowkhatsincluding Stacking Of Materials As Directed By Engg-In-Charge Within A Distance Of 60 Meters. 6 Dismantling Reinforced Cement Concrete Or Reinforced Brick Work, Including Stacking Of Dismantled Materials As Directed By Theengineer-Incharge Within A Distance Of 60 Metres. 7 Scrapping Old White Or Colour Wash Or Distemper Including Disposal Of Refuseas Directed By The Engineer-I / C Within A Distance Of 60 M. 8 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. 9 Disposal Of Rubbish / Debris Out Side The Uppcl Area As Per Direction Of Er / In- Charge Including Cartage, Labour And Materials, T&P Etc. Required For Proper Completion Of The Work. ( No. Deduction For Voids Shall Be Made ) . 10 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- ( Part I ) :2011 ( Board With Bis Certification Marks ) . 11 Providing And Fixing False Ceiling At All Heights With Integral Densifiedr Armstrong False Ceiling Tiles Of Size 595X595 X12 Mm Of Approved Texture, Design And Patterns Having Nrc ( Noise Reduction Coefficient ) Of 0.50 ( Minimum ) As Per Is 8225:1987, Light Reflectance Of 85% ( Minimum ) . Non Combustible As Per Bs:476 ( Part-4 ) , Fire Performance As Perbs:476 ( Part 6 &7 ) , Humidity Resistance Of 100%, Thermal Conductivity < 0.043 W / M K As Per Astm 518:1991, In True Horizontal Level Suspended On Interlocking Metal Powder Coated T-Grid Of Hot Dipped Galvanised Iron Section Of 0.40 Mm Thick On Silhouette Profile, Rotary Stiched Double Webbed White With 6 Sub Head : 26- New Technologies And Materials 1632 Mm Reveal Profilewhite / Black ) , Comprising Of Main-T Runners Of Size 15X42 Mm Of Length 3000 Mm, Cross - T Of Size 15X42 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 15X42 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items ( Galvanizing @ 80 Grams Per Sqm ) I.E. 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 22X19x0.40 Mm Of Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450 Mm Center To Center And 40Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In- Charge. 26.23.1 With 12 Mm Thick Armstrong Miniralfobre Sound Absorbing Sheet 12 Providing And Laying Floor Of 10 Mm Thick Vitrifiedtiles In Flooring Or Skirting Of Approved Brand ( Bell, Johnson Or Equi. Make ) Size Of 600X600 Mmof Approved Shade, Colour And Pattern , Laid Over Base Cement Mortar 1:4 Mix Including Finishing The Joints With White Cementmixed With Pigment To Match The Shade Of Tile Including Cost Of All Material, Labour And T&P Required For Proper Completion Of The Work. 13 Same As 12.18 Above But For Providing And Fixing 8 Mm Thick Vitrifiedtiles In Flooring Or Skirting With Adhesive Of Approved Quality On Existing Smooth Floor Including Cost Of All Material, Labour And T&P Required For Proper Completion Of The Work. 14 Providing And Laying Of16 Mm Thick Granite ( Black / Brown ) Inflooring Or Skirting , Of Approved Shade, Colour, Size And Pattern , Laid Over Base Cement Mortar 1:4 Mix Including Finishing The Joints With White Cementmixed With Pigment To Match The Shade Of Granite Floor Including Cost Of All Material, Labour And T&P Required For Proper Completion Of The Work, As Per Direction Of Engineer Incharge. 15 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite Work 16 Providing , Making & Fixing Wall Panneling As Per Drawing From Seasoned Wood Ofmirindiframe Of 2X1.5 Size Placed Horizontally And Vertically Both Way @ 2 C / C. The Frame Workfitted In Floor With The Help Of Nails , Screw Then Framework To Be Covered With 12 Mm Thick Plywood Fromthe Help Of Fevicol, Nails And Screw. Then Making Grooves With 6Mm Mdf Ply With The Help Of Fevicol, Nails And Screw. The Final Surface To Be Finished With 1Mm Thick Laminateand Grooves Topolished As Per Design..As Per Requirement And Direction Of Engineer I / C Including Cost Of All Material, Labour, T & P Etc Required For Proper Completion Of Work 17 Providing , Making & Fixing Fullheightwooden Partitions As Per Drawing From Seasoned Wood Ofmirindiframe Of 2X1.5 Size Placed Horizontally And Vertically Both Way @ 2 C / C. The Frame Workfitted In Floor With The Help Of Nails , Screw Then Framework To Be Covered With 12 Mm Thick Plywood From Both Side With The Help Of Fevicol, Nails And Screw. Then Making Grooves With 6Mm Mdf Ply With The Help Of Fevicol, Nails And Screw. The Final Surface To Be Finished With 1Mm Thick Laminate On Both Sides And Grooves To R Polished As Per Design..As Per Requirement And Direction Of Engineer I / C Including Cost Of All Material, Labour, T & P Etc Required For Proper Completion Of Work. 18 Providing , Making & Fixing Low Heightwooden Partitions As Per Drawing From Seasoned Wood Ofmirindiframe Of 2X1.5 Size Placed Horizontally And Vertically Both Way @ 2 C / C. The Frame Workfitted In Floor With The Help Of Nails , Screw Then Framework To Be Covered With 12 Mm Thick Plywood From Both Side With The Help Of Fevicol, Nails And Screw. Then Making Grooves With 6Mm Mdf Ply With The Help Of Fevicol, Nails And Screw. The Final Surface To Be Finished With 1Mm Thick Laminate On Both Sides And Grooves To Be Polished As Per Design.. Top Of Partition Shall Be Coverd With Teak Wood Beading With Polish As Per Requirement And Direction Of Engineer I / C Including Cost Of All Material, Labour, T & P Etc Required For Proper Completion Of Work. 19 Providing & Fixing Of Flush Door Laminated Both Side Complete With All Fittings, Round Mortis Lock, Door Closer Etc All Complete All Complete As Per Drawing, Specification And Directionas Approved By The Architect / Engineer -In-Charge 20 Applying Birla Or Equivalent Putty On New Interior Or Exterior Surface Over One Coat Of Water Based Cement Primer Of Ici Or Equivalent Brand For Smoothening And Levelling Of The Surface As Per Requirement And Direction Of Engineer I / C Including Cost Of All Material, Labour, T & P Etc Required For Proper Completion Of Work. 21 Painting One Coat With Acrylic Emulsion Paint Of Berger / Asian / Ici Or Equivalent Paint ( Paint And Water In The Ratio 1:1 By Volume ) Over Prepared And Primed Surface Of Cement Concrete, Cement Plaster And Bricks Including All Labour, Material And T&P Etc Required For Proper Completion Of The Work, ( Preparation Of Base With Birla Putty Etc. And A Coating Of Primer Shall Be Paid Extra ) . 22 Same As Above In Item No.But For Every Coat After First Coat Of Acrylic Emulsion Paint Of Berger / Asian / Ici Or Equivalent Paint. 23 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requiredincluding Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 24 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5.50 Mm Thickness: 25 Providing And Fixingacp In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Acpof 4.0 Mm Thickness 26 Providing And Fixing Sun-Film Of Gareware Or Equivalent Make Onglass Panes Of Door And Window Shutters Including Cost Of Allmaterials, Labour And T&P Etc. Required For Proper Completion Ofthe Work. 27 Providing And Fixing In Place A Full Height Storage Cabinet 450 Mm Deep Made With 19 Mm Thick Isi Marked Ply Borad, All Interior Surfaces To Finished With Pasting Of 0.8 Mm Thick Mica And All Exterior Surfaces To Be Finshed With Pasting Of 1 Mm Thick Mica Of Texture And Colour As Approved By Engineer In Charge Including All Labour, T&P, Other Items Like ( But Not Limited To ) Fevicol, Nails Screws, Higes, Sliders, Door Handles, Multipurpose Lock Of Godrej Or Equivalent Rate Etc. Required For Proper Completion Of Works, To Be Measured Interms Of Front Area Only 28 Providing And Fixing In Place A Full Height Storage Cabinet 450 Mm Deep Made With Ms Sheet Of 1.2 Mm Thickness With Proper Locking Arrangment, Handle Etc Required , Painting With Spray Enamel Paintingas As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 29 Providing & Fixing Of Excutive Office Computer Work Station Cum Work Table In 11Th Floor Of Shakti Bhawan Extn. Building. The Unit Shall Be Of Size 0.9X0.60 Mtr Worktop & 0.76 Mtr Hight. The Entire Above Unit Shall Be Fabricatrd With 19 Mm Block Board Superior Quality Swastik Made All Extirior Surface With Approved Quality 1 Mm Sunmica Laminate And Intirior Faces Finished With 10X20 Mm Thick Sprit Polish Teak Wood Beading.T.One No Drawer Nd One Flap Door Fabricated With The Help Of 19 Mm Block Board Swastik Block Board / Green Or Equivalenthe Cup-Board Shall Have Lockablemagnet Door Fabricated With 19Mm Block Board Fixed To Cup-Board With Magnet And Having In Handle The Main Table Rack Shall Be Approved Matel Handle And Necessery M.P Lock. All Drawrs Shall Be Provided With Approved Qaulity Slider Machnism. The Foot Board Shall Be Also Provided In Above Three Peace. Excutivework Station .The Work Include Cost Of All Labour, Material T&P Required For Proper Completion Of Work. 30 Cement Concrete With 2Cm Gauge Approved Hard Stone Ballast, Coarse Sand ( F.M. 1.8 To 2.5 ) And Cement In Proportion Of 4:2:1Including Supply Of All Materials, Labour, Side Shuttering Ifrequired And T&P Etc. Required For Proper Completion Of Work. 31 First Class Half Brick Work In Superstructurein 1:4 Cement And Coarse Sandf.M.1.8 To 2.5 ) Mortar In S.S.Including Supply Of All Materials, Labour & T&P Etc. Required For Proper Completion Of Work. 32 Rcc Work With Cement, Approved Coarse Sand And2 Cm Gauge Graded Approved Hard Stone Ballast Like Granite, Quartzite Etc From Dalla, Jhansi Or Other Quarries In Proportion 1:1.5:3In Lintels Of Doors And Windows, Excluding Supply Of Reinforcement & Its Bending But Including Its Fixing And Binding The Same With Binding Wire, Including Cost Of All Other Materials Labour And T&P. 33 Mild Steel Or Iron Work In Heavy Sizes Such As Trusses Built Up Gates, Door Framesh, Record, Racks Roof Work Gates Etc Wrought To Required Frorm Including Holes Rivetting Or We4lding Where Necessary And Also Fixing In Proper Position And Alignment Including Cost Of All Materiasl Supplied By Contractor. 34 Provinding & Fixing Of Ancor Fastner Wedge Type ( 12 Mm Dia 50 Mm Long ) Including Supply Of All Labour, T&P Etc. Required For Proper Completion Of The Work 35 12 Mm Thick Plaster With Cement Mortar Consisting Of One Part Of Cement & Six Part Of Coarse Sand ( 1:6 ) , Minimum Thickness Not To Be Less Then 10 Mm Including Supply Of All Material, Labour And T&P Etc For Proper Completion Of Work. 36 Supply And Fixing 24 B.W.G , G.C. Iron Sheet Roofing .Fixed In Position With J Or U Bolts 10 Mm. Dia With G.I. Limpet & Bitumen Washers Including Supply Of All Materials, Labour, Wastage. And T&P Etc. Required For Proper Completion Of The Work. 37 Supply And Laying 6 Mm Thickglazed Tiles Of Size 300X450 Mm In Skirting / Dado Laid With1:3 Cement And Approved Coarse Sand Mortar Finished With Whitecement Slurry, Jointing And Polishing Complete, Including Supplyof All Materials, Labour And T&P Etc. Completion Required For Proper Completion Of The Work. 38 Providing And Fixing Full Way20 Mm Dia G.M. Gate Valvewith Wheel, Isi Mark Heavy Quality Including Supply Of All Materials, Labour And T&P Required For Proper Completion Of Work. 39 Providing And Fixing Full Way 65 Mm Dia G.M. Gate Valvewith Wheel, Isi Mark Heavy Quality Including Supply Of All Materials, Labour And T&P Required For Proper Completion Of Work. 40 Making Water Connection Of Pipe Line With Mains ( 25 Mm To 100 Mm ) Dia. By Providing And Fixing Ferrule ( 25 Mm Dia ) Gi Union And Nipple Including Cutting And Threading The Pipe, Inspection, Testing, Cutting And Making Good The Road, Executing Bond With Nagar Maha Palika, Fixing Of Pipe Line Upto The Points Near The Building Complete Work Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of Work. 41 Providing And Fixing 600 Mm X 450 Mm Beveled Edge Mirror Of Atul, Kiran Makeglass With Indian Polish 6.50 Mm Thick Complete With Back Of 600 Mm X 450 Mm X 6 Mm Hard Board Sheet Fixed To Wooden Cieats With C.P. Brass Screws And Washers Including Supply Of All Materials, Labour And T&P Etc.Required For Proper Completion Of The Work. 42 Providing And Fixing 750 Mm X 20 Mm Size C.P. Brass Towel Rail Of Approved Qualityincluding Bracketsincluding Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work And Cutting And Making Good The Wall Plaster Etc. Required For Work. 43 Providing And Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Brass Screws Including Supply Of All Materials, Labour And T&P Etc.Required For Proper Completion Of The Work. 44 Supply And Fixing 100 Mm Pvc Nahani Trap India Make Of Heavy Approved Quality Complete With Ci Grating, Includingsupply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. 45 Providing And Fixing Ci Grating 100 Mm Dia Includingall Materials, Labour Cartage T&P Etc.Required For Proper Completion Of The Work. 46 Providing And Laying , Pvc ( Finolex Orquivalent ) Pipe Excluding Cost Of Excavation, C.C. Etc Including Its Jointing And Connection, Allmaterials, Labour And T&P Etc. Required For Proper Completion Of The Work 110 Mm Dia. 47 Providing And Fixing 110 Mm Dia Swr, Pvc ( Finolex Or Equivalent ) Bends Including Cost Of All Materials, Labour And T&P Etcrequired For Proper Completion Of The Work. 48 Providing And Fixing 110 Mm Dia Swr, Pvc ( Finolex Or Equivalent ) Trap Including Cost Of All Materials, Labour And T&P Etcrequired For Proper Completion Of The Work. 49 Providing And Fixing 110 Mm Dia Swr, Pvc ( Finolex Or Equivalent ) Socket Including Cost Of All Materials, Labour And T&P Etcrequired For Proper Completion Of The Work. 50 Providing And Fixing 110 M M Dia Swr, Pvc ( Finolex Or Equivalent ) Plain Teeincluding Cost Of All Materials, Labour And T&P Etcrequired For Proper Completion Of The Work. 51 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : ( A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry 52 Core Cutting Work 160 Mm Dia For Brick / Rccwall Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. 53 Providing And Fixing Of Supreme Make Or Equivalent Make 160 Mm Dia Pvc Pipe Of 6 Kg Pressure For Ground Floor To 04Th Floor Vertically In Duct / Wallincluding Cost Of Scafolding, All Labor Material, T&P Etc Required For Proper Completion Of The Work 54 Supply And Fixing Of Of Waste Coupling Of Make Model No-Ald-705L130of Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 55 Supply And Fixing Ofhealth Faucet Model No-Ald-Chr-565 With 1.00 Mtr Long Flexible Tube In Chrome Finish And Wall Hookof Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 56 Supply And Fixing Ofsingle Piece-Wc With Uf Soft Close Slim Seat Cover, Fixing Accessories, Accessories Set And Cistern Fittings, Size: 370X670x720 Mm, P Trap-180Mm Model Lys-Wht-38851S220ufsm Of Jaguar Make Or Equivalent. Make The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work As Approved By E / I. 57 Supply And Fixing Of Wash Basin Vanity+Mirrorsize-605X470x540 Padestal Model No- Kb0331 Of Kerovit Make The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work As Approved By E / I. 58 Supply And Fixing Of Paper Holder Model No Ahs-1553 Of Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 59 Supply And Fixing Of Soap Dispencer Model No Akp-35735P Of Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 60 Supply And Fixing Of Two Way Bib Cock With Wall Flange Model Noopp-15041Pm Of Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 61 Supply And Fixing Ofurinal With Fixing Accessories, Size: 370X315x620 Mm Model -Urs-Wht-13253O F Jaguar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 62 Supply And Fixing Ofsensor Mini Concealed Type Flushing Valve For Urinal Complete Set With Installation Box ( Battery Operated ) Model-Snr-Stl-51083 Jaguar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 63 Supply And Fixing Of Basin Trap With Regular Swinging Spout ( Wall Mounted Model ) Withmodel No-Flr-Chr-5347N Of Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 64 Supply And Fixing Of Angular Stop Cock With Wall Flange Model No-Opp-15053Pmof Jaquar Make Or Equivalent. Make As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 65 Supply & Placing Of Wooden Planter Made With 19 Mm Block Board Size 600X600x600 Mm With Natural Indoor Plants As Approved By E / I. The Work Includes Cost Of All Labour, Material T&P For Proper Completion Of Work 66 Providing & Fixing Of Roller Blinds Of Approved Shade As Per Drawing & Specificationas Approved By The Architect / Engineer -In-Charge 67 Wiring Point For Light With 1.5 Sq.Mm Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable Inpvc Conduitwith 1.5 Sq.Mm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit Pipe Concealed In The Wall Complete With Copper Earth Continuity Wire Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3 Mm Thick Phenolic Laminated Backlite Sheet Etc, Complete In All Respect, As Directed Including Matching Colour Wash.For Light / Fan Points With Modular Type Switch In Place Of Piano Type Switch. 68 Wiring Point For Fan / Fresh Air Fan ( Light Duty Exhaust Fan ) With 1.5 Sq.Mm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduitconcealed In The Wall Complete With Copper Earth Continuity Wire Gp Box, Piano Type Switch & Ceiling Rose / Angle / Batten Holder On 3 Mm Thick Phenolic Laminated Backlite Sheet Etc, Complete In All Respect, As Directed Including Matching Colour Wash. With 1.5Sq. Mm. Frlsh Pvc Insulated Multidtrand Copper Conductor Cable As Earthwire Drawninside The Conduit Add For Light / Fan Points With Modular Type Switch In Place Of Piano Type Switch.For Light / Fan Points With Modular Type Switch In Place Of Piano Type Switch 69 Wiring Point For Call Bell With 1.5 Mm. Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit Pipe Concealed In The Wall, Complete With Copper Earth Continuity Wire And Piano Type Bell Push Or 2 Pin Socket Etc., Complete In All Respect Including Matching Colour Wash. For Call Bell Point With Modular Type Bell Push In Place Of Piano Type Bell Push. 70 Supply And Fixing Of Call Bell Of Approved Make On Polished Mdfeg / Teak Ply Board Including Making Connection Etc. Complete In All Respect. 71 Wiring Point For Plug With 1.5 Sq.Mm Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq.Mm Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earthwire Drawn Inside The Conduit Concealed In The Wall, Complete With Copper Earth Continuity Wire, Gp Box, Piano Type Switch And Socket Etc. Complete In All Respect Including Matching Colour Wash. For Plug Point With Modular Switch & Socket In Place Of Piano Type Type Switch & Socket. 72 Supply And Fixing Of Power Plug With 20 Amp. / 250 Volt Flush Type Modular Switch And 5 Pin 20 Na / 250 Volt Flush Type Universal Modular Socket Switch On Concealed M.S. Box Including Supply Of All Material, Labour T&P Etc. Required For Proper Completion Of Work. For Plug Point With Modular Switch & Socket In Place Of Piano Type Type Switch & Socket. 73 Supply And Wiring Of Submain With Two Number 2.5 Sq.Mm Frlesh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia. Heavy Duty ( 2 Mm Thick ) Pvc Conduitwith 1 Number 1.5 Sq.Mm. Frlesh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable As Earth Continuity Wire Concealed In Wall, With One Number Copper Earth Continuity Wire Etc. Complete In All Respect. 74 Supply And Wiring Of Submain With Two Number 4 Sq.Mm Frlesh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2 Mm Thick ) Pvc Conduit On Consealed In Wall, Complete With One Number Copper Earth Continuity Wire Including Matching Colour Wash Etc., Complete In All Respect. 75 S / F Sheet Steel Encloser Surface / Flush Mounting Feeted With 20Amp. 2 Pin & Earth Meatel Clad Scrapping Earth Plug And Socketcomplete In All Respect. As Respect As Directed At Site By Engineer In Charge. 76 Supply & Fixing Of 36 Watt Indoor Recess Mounting Led Square Fitting For Armstrong Cieling Having Powder Coated Die Cast Aluminium Housing Body With Extended Heat Sink And Diffuser Of Special Polycarbonate Material And Driver Set Complete In Allrespect. 77 Supply And Fixing Ofrecess / Surface / Pendent Mounting Round 6 Watt / 8 Watt Led Down Lighter Havingpowder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflecter And Driver Set Complete All Respect . 78 Supply And Laying Of Aluminium Conductor Pvcinsulated Armoured Served Sheathed Cables 1100 Volts Grade At A Depth Of 750 Mm Below Ground Level Over A Cushion Of 75 Mm. Thick Sand All Around And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer Incharge, Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc.35 Sq.Mm 3-1 / 2 Core 79 Supply And Fixing Of Plain Or Pin Type Copper Tin Plated Cable Socket ( Lug ) To The Cable Leads, Insulating With Tape And Making Connection Etc. Complete In All Respect As Per Direction Of The Enginner-Incharge 80 Supply And Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armourd Served Sheathed Underground Cable Including Rubber Ring Etc. Complete In All Respect. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. 81 S&F Of 125 Amp 3 Pole Mccb ( 25 Ka ) Thermal Magnetic Release. 82 S / F 6 Amp To 32 Amp. Spmcb ( 10K ) C Curve 83 100Amp Tpn415 V 4Pole Isolater 84 S&F Surface / Flush Mounting 6 Way Vtpn Distribution Board With Additionalmetal Door Without Mcb Complete In All Respect, As Directed By Engineer In Charge. 85 Supply And Fixing And Concealing Of 20Mm Dia. 2Mm Thick Pvc Conduit Pipe With Isi Mark Embossed And With Pvc Accessories Confirming To Is No. 3419 For Drawing Wires Duly Sealed At Joints With Original Resin / Adhesive To Make The Complete Piping Rigid, Plastering With Cement Sand Mortar Finished To The Level With Matching Colour Wash Including Cost Of All Material Labour And T&P Etc Required For Proper Completion Of The Work As Per Directions And To The Satisfaction Of Engineer In Charge. 86 Supply And Fixing And Concealing Of 25 Mm Dia. 2Mm Thick Pvc Conduit Pipe With Isi Mark Embossed And With Pvc Accessories Confirming To Is No. 3419 For Drawing Wires Duly Sealed At Joints With Original Resin / Adhesive To Make The Complete Piping Rigid, Plastering With Cement Sand Mortar Finished To The Level With Matching Colour Wash Including Cost Of All Material Labour And T&P Etc Required For Proper Completion Of The Work As Per Directions And To The Satisfaction Of Engineer In Charge. 87 Supply And Fixing And Concealing Of 32 Mm Dia. 2Mm Thick Pvc Conduit Pipe With Isi Mark Embossed And With Pvc Accessories Confirming To Is No. 3419 For Drawing Wires Duly Sealed At Joints With Original Resin / Adhesive To Make The Complete Piping Rigid, Plastering With Cement Sand Mortar Finished To The Level With Matching Colour Wash Including Cost Of All Material Labour And T&P Etc Required For Proper Completion Of The Work As Per Directions And To The Satisfaction Of Engineer In Charge. 88 Supplying And Drawing Of Utp 4 Pair Cat-6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required 1 Run Of Cable. 89 Supply And Fixing Of 400Mm Wall Fan Of Crompton / Havells / Make. 90 S&F Cat6 Utp 24 Awg Patch Cord 1 M, Plug 30U Snagless. 91 S&F Cat6 Utp 24 Awg Patch Cord 2 M, Plug 30U Snagless. 92 Supply & Fixing Of 24 Ethernet Ports Switch With 2Sfp Ports. 93 Supply Of Jack Cat 6 Keystone Utp-White. 94 Supply And Testing Of Contuinity Of Face Plate- Double ( Keystone Jack Square ) . 95 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.2 Pair. 96 Supply& Laying Of20 Pair Telephone Cable Complete With Connections, Testing And Commissioning Etc. As Required. 97 S&F Mdf Box For Telephone 50 Pair. 98 A ) - At First Remove The Fiber Glass Wool Insulation With Cover From The Existing Duct And Shifted Outside From Shakti Bhawan Premisess.B ) - Secondly Dismantle The Duct From The Celling By Properly By Skilled Duct Man By Chain Pulley And Other Accessories And Shifted From Required Floor To The Basement. 99 Supply, Installation, Balancing And Commissioning Of Fabricated At Site Gss Sheet Metal Rectangular / Round Ducting Complete With Neoprene Rubber Gasket, Elbow, Splitter Dampers, Vanes, Hangers, Support Etc As Per Drawing And Specification Of Following Sheet Thickness Complete As Required. 100 ( A ) 22 Gauge 101 ( B ) 24 Gauge 102 Supply And Fixing Of 19 Mm Thickness Duly Laminated Aluminium Foil Mat Finishnitrile Rubber Insulation On Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Required. 103 Supplying, Fixing, Testing And Commissioning Of Supply Air Diffusers Of Powder Coated Aluminium With Volume Control Dampers Complete As Required. 104 Supplying, Fixing, Testing And Commissioning Of Return Air Diffusers Of Powder Coated Aluminium Without Volume Control Dampers Complete As Required. 105 Supplying, Fixing, Testing And Commissioning Of Gi Volume Control Duct Dampers Complete Withneoprene Rubber Gasket, Nuts, Bolts Etc As Required. 106 Charges For Highly Skilled Fitter. 107 Labour Charge For Dismantle False Celling And Refixing The Same, Ducting Work By Fitter, Grade-2. 108 Dismantling Of Pvc Armoured Cable 2 Core 1.5 Sq. Mm. 109 Dismantling Of Smoke Detector With Base. 110 Dismantling Of Response Indicator. 111 Supply Installation, Testing And Commissioning Of2 Core 1.5 Sq Mm Pvc Insulated Copper Conductor Armoured Cable With Saddle Including Termination All Labour And Material As Required. 112 Installation, Testing And Commissioning Of Multi Sensor Smoke Detector With Base Complete As Required. 113 Installation Testing And Commissioning Of Response Indicator.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
27.
Power #10168894 Price Bid
Tender For Construction Of Division Office Building And Misc. Civil Works For Newly Created Office Of Xen (Oandm) At Kathumar Alwar - 1 PART-A 2 1.34Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 3 1.36Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 4 1.8E/W in excavation by mechanical means (hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5m in whichor 10 sqm on plan) including dressingof sidesand ramming of bottoms, lift up to 1.5 m, including taking outthe excavated soil and depositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils. 5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. (A) 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (3.1.6) 6 RR stone masonry for with hard stone in foundation and plinth in CSM above 30cm thick wall in CM 1:6 (1cement :6 Sand) (6.1.6) 7 Add extra for Random Rubble stone masonry with hard stone in(A) Wall upto 30cm. and less thickness. (6.3.4) 8 4.1Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 9 4.9Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 10 4.2Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 11 4.3Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 12 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :(A) Columns, pillars, posts and struts etc. (4.10.3) 13 (B) Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. (4.10.2) 14 5.2.2Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) 15 Halfbrick masonry in superstructure, above plinth level upto floor V level using bricks of designation 75.Cement mortar 1 : 4 (1 cement : 4 coarse sand) (1cement:6 coarse sand). (5.8.2) 16 6.18.1Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 :Upto 15 cm. thick. 17 4.13.2Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Hot rolled deformed bars (IS : 1139). 18 10.17.1Grading roof for water proofing treatment withwater proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 19 12.7Finishing with neat cement (punning). 20 10.22Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 21 11.26Random rubble dry stone Kharanja under floor. 22 9.5/B-9Providing & fixing T-iron frames for doors, windows and ventilators of mild steel Tee - sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 23 S & F in walls machine cut and polished stone shelves,tands and in 1:3 with machine cut edges:(A) Kota stone minimum 30 mm thick (6.17.3) 24 (B) Sand or other approved stone 25mm thick. (6.17.1) 25 8.13.2.1/B-8Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehydration in glue both sides with approved steel fittings complete as per annexure ‘A’ 30mm thick. Commercial veneer both side. 26 8.14/B-8Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 27 (16.1.1.1)P & F anodized aluminum work (Anodized to be got done from approved Anodiser) for doors, windows, ventilators and partition with extruded built up standard tubelar and other sections of approved make confirming to IS : 733 & IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasters i/c necessary filling up of gas at junctions, at top , bottom and sides with required PVC / Neoprene felt etc. aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required i/c cleat angle Aluminium snap beading for glazing/paneling , C.P. brass/stainless steelscrews, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer in charge.(Glazing and paneling to be paid for separately). (a) For fixed Portion.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 28 (b) For shutters of doors, windows and ventilators including P&F hinges / rollers etc. and making provision for fixing of fittings wherever required( locks shall be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) (16.1.2.1) 29 16.2Extra for shutters of slidingaluminum windows 30 16.5.2/B-16 P&F glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/Neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer in charge.(Cost of aluminium snap beading shall be paid in basic item.). With glass panes of 5.0mm thickness (weight not less than 13.75 kg/S.pm.) as per IS: 2835. 31 16.11S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding. 32 8.7 (a)Extra for providing frosted glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 33 16.15Providing and fixing sun control film, thickness of film 1 Mil Visible Light Transmittance 4-24% & Solar Energy Transmittance 42-51% & Total solar Energy rejection 37-43%of approved colour and shade , complete in all respect , at all level , as directed by engineer- in -charge. 34 (16.44.2)Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 50mmx48mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Powder coating aluminum ( minimum thickness of powdercoating 50 micron) 35 9.10Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). 36 16.6.1/B-16P&F double action hydraulic floor spring of approved brand and manufacture to aluminium door shutter confirming to IS : 6315 including cost of cutting floors and cover plate with brass pivot and single piece M.S. With stainless steel cover plate. 37 16.8/B-16 P/F 100mm brass locks for Aluminium door including necessary cuttingand making good etc. complete. 38 16.9.2Providing and fixing aluminium U shape handle of size 100mm with SS screws etc. Complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminium 39 8.26Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. 40 12.2.2Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finished: (A) 20mm thick 41 12.3.2Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: (A) 20mm thick 42 (B) 12mm thick (12.3.3) 43 12.5/B-126mm thick cement plaster to celling of mix 1:3 (1 cement : 3 fine sand) 44 7.12Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 45 7.13Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 46 7.5.6(ii)Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Rajasthan Black1501 Cm2 to 3600 Cm2 Tiles 47 7.6.2(i)Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone WorkFull Edge moulding 48 7.23Providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter V type including machine polishing to groove to give high gloss finish etc. complete as per design approved by engineer in charge 49 7.8Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone workincluding necessaryholesfor pillar taps etc. including rubbing and polishing of cut edges etc. complete 50 7.25.1P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.size600 mm X 600mm 51 (B-11.17.4)Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)Ordinary cement without any pigment. 52 P & F of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80X25 mm X 1.25mm thick with 1.00mm MS sheet to spot welded including holdfasts of 15X3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts & twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate & spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer in charge. (9.39) 53 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. 54 9.8.1(A) Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 55 16.56(a)Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Grade 304 56 13.34.1Making of holein R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EIFromdiameter 100mm to 150mm 57 16.58/B-16 Supplying and fixing Rollor Blinds of good quality and approved make made out of Imported fabric including Roller Mechanism and lock with chain system with all necessary hooks etc. complete as per direction and sample approved by engineer-in-charge. 58 10.33.2Providing & fixing calcium silicate perforated ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge of thickness of tiles as mentioned below:-8 mm thick 59 12.45.1Applying priming coat :With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 60 12.46.1 /B-64Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (A) Two or more coats on new work. 61 12.22.1Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.New Plastered Surface (three or more coats) 62 12.37.1 /B-12Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: (A)New work (two or more coats) over and i/c scrapping and priming coat with cement primer. 63 12.42Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 64 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 65 12.19Making grooves as per design in plaster 10mm to 20mm wide. 66 (3.8)Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification . 67 1.2.2P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. 68 1.3P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 69 17.48P/F wall mounted 600mm long grab bar as approveddesign, made of 35mm stainless stell pipe having anti-bacterial Nylon surface with contour finish for better grip. Grab bar should be mounted on wall at height of 800mm from the finish floor level complete in all respect as per Harmonized guidline & Satification of Engineer-in Charges. Make Cera (B2210106) 70 1.7.2P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I white for EWC. 71 1.59P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 72 2.33.5 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 73 1.65 P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge 74 1.52.1P & F Soap Dish or Tray of approved quality/make C.P. brass 75 1.51.2P & F Toilet Paper Holder with rod of approved quality/make: C.P. brass heavy & Superior quality. 76 1.69.2Providing & Fixing premium qulaity WVC Urinal with PVC waste pipe, dome couplings, concealed iron brackets or screws etc. complete.Flat Back (large) or half stall size 590x375x390 mm. 77 1.16.3P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble. 78 1.66P & F C.P. brass Urinal Spreader for Large Urinal of heavy duty of approved make as per direction of Enginner-in-Charge 79 1.36.4P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 580 mm x 450 mm 80 1.40P & F 1st quality WVC pedestal for wash basin. 81 (1.38.9.1) P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :1.0 mm thick stainless steel AISI -304 & IS 13983-1994kitchen sink of approved make as per Engineer-in-chargewith large waste coupling. Overall size 18 x 16 x 6(inches)Bowl size 16x14x6 (inches) 82 P & F Towel Rall or Ring of approved quality/make.C.P. brass Towel Rail with brackets 450x20mm. (1.47.3) 83 2.26.2/S-2P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 300 ltr capacity 84 P & F looking Mirrors with P.V.C. frame of approved (Atul, Modi Guard, Saint Gobin or equivalent).Size 500 x 400 mm.(1.45.1) 85 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)(A) 20mm nominal size. (2.38.2) 86 (B) 25 mm nominal size (2.38.3) 87 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).(A) 20mm nominal size (2.39.2) 88 (B) 25 mm nominal size (2.39.3) 89 2.7.3 /S-2P & F Bib cock (IS: 8931 Mark), Superior quality of approved make:(A) C.P. brass bib cock 15mm nominal bore. 90 2.11.1/S-2P & F Ball Cock (IS: 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. Not less than 300 gm,15mm. 91 P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make:(A) Gun metal 15 mm nominal bore. (2.15.1) 92 (B) Gun metal 25 mm nominal bore. (2.15.3) 93 1.20.2P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVCbend as per IS : 7231 . 94 2.12.1/S-2P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked) 95 P & F 15mm. Dia Connection pipe of approved quality/ make: (A) PVC Pipe with C.P. Brass nuts upto length 450mm.(2.13.3) 96 (3.19.1)Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M 97 3.22.3Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth. 98 3.27.1Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect. 99 P & L CC 1:5:10( stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150mm thick bed concrete ( Width W= Dia of pipe in Cm + 30Cm.) conrete width to be reduced from width W at centre of pipe to 0 at top of pipe(Excluding cost of pipe).100 mm diameter S.W. Pipe.(3.3.1) 100 Construction of chamberin all typeof soli with300 mm. thick masonry in CM 1:6 m 10Cmthick C.C1:5:10 infoundation, 20mm thick inside plaster in CM 1:6, finshed with floatinf neat cenent50 mm thickM-15 grade C.C flooring, Ferro work etc. complete as perdesing includingdisposal of surplus earth within a lead of50 mtr. Inside size 300 X 300 mm depth upto 0.5 M Cement cover with frame.(3.21.1) 101 P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant.(A) 75 mm dia. (3.16.2) 102 (B) 110mm dia. (3.16.3) 103 P & F rigid pvc pipe fittings (IS : 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant :110 mm dia.(A)Bend 45˚(3.17.8.ii) 104 (B) Bend 87.5˚.(3.17.9.ii) 105 (C) Vent Cowel (3.17.12.ii) 106 (D) Plain Tee (3.17.3 (ii)) 107 (E) Door Tee (3.17.4 (ii)) 108 (F) Gully trap (3.17.27) 109 Supply & Fixing G.I. Union ISI marked in G.I pipes line as required complete in all respect of size . (A)15 mm dia nominal bore B Class. (2.32.1) 110 (B)25 mm dia nominal bore B Class. (2.32.3) 111 P & F Grating of approved quality/ make Stainless steel sheet size 125 mm dia. (1.48.1) 112 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. (A) Short point (up to 3 mtr.) (1.1.1) 113 (B) Medium point (up to 6 mtr.) (1.1.2) 114 © Long point(up to 10 mtr.) (1.1.3) 115 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board (1.3.1) 116 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR (7.36) 117 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 2 x 2.5 sq. mm. + 1x1.5sqmm (4.1.7) 118 (B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (4.1.14) 119 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 8 SWG G.I. ( Hot Dipped) Wire. (14.6.8) 120 14.2Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing. (17.2.2) 122 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 mm Dia. (18.18.1) 123 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR. (5.9) 124 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). 6 A to 32 A rating. (6.1.1.2) 125 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR. Four pole Isolator. 63 A rating. (6.2.3.2) 126 6.10.3.4Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR.Metal door (Three phase) IK-09 and IP-43with Metal end box.12 Way 127 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 6.0 Sq. mm 2 core. (11.2.2.1) 128 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(A)LED Street Light fixture with Minimum lumen output 11225 lm. (18.12.6) 129 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg. (24.67.3) 130 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.12) 131 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.13) 132 Providing & Fixing of IS 11037:1984marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(7.20) 133 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) (15.7.1) 134 15.11.2Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 300 mm sweep 135 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .(A) Recessed MountingMinimum lumen output 4200 lm. (17.4.1.3) 136 (B) Surface MoutningMinimum lumen output 4200 lm. (17.4.2.3) 137 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Surface Mounting (with extruded alumn. Housing )(A) Minimumlumen output 650 lm. (17.3.2.1) 138 (B) Minimum lumen output 1300 lm. (17.3.2.2) 139 7.26Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 7.27.3Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. 10 A bell push 141 20.1Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 20.5.1Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Single Aperture 143 20.4.1Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6, Un-sheilded Information Outlet 144 20.6.2Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 145 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord(A) 2 Mtr . (20.7.1.3) 146 (B) 3 Mtr (20.7.1.4) 147 20.16.4Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .15 U Rack with Width 600 mm & Depth 400 mm + 100 mm 148 20.18.2Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .24 Port 149 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR.(A) 32 mm. (1.4.3) 150 (B) 20 mm. (1.4.1) 151 (2.2.1) Construction of Tube Well from ground level and upto 100 mtr. depthto accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. by percussion/ rotary drilling methodas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications for removal of overburden. The work includes the cost oflowering of casing pipe, but excludes the cost of casingpipe. Nominal bore 200 mm dia. 152 Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.Nominal bore 150 mm dia. (P 2.3.1) 153 (B) Add 15% extra on above item (Item No 2.3.1 to 2.3.3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. (P 2.3.4) 154 (E-112/21.2.2.1)Supply & fixing of PVC threaded casing pipes for Tube well (IS 12818:1992) of3mtr. Each for depth up to 1200 ft. Plain and strainer Casing CS for Depth upto 400ft. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . more than400 ft to 1200 ft. Depth 40mm dia 155 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. (P 2.22) 156 (4.8.4)S & F tube well cover of M.S.sheet (6mm thick) with nuts and boltscomplete for casing size:200mm dia Nominal bore 157 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 3 core 6.0 Sq.mm (P 2.19.2) 158 (E-112/21.3.2)Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .16mm (suitable above 50mm & up to 75mm OD pipe) 159 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes. 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) (P 2.11.2) 160 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 200 mm dia nominal bore of 5.4mm thickness. (P 2.12.3) 161 21.6.1.4SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump setssuitable for 100/150mm dia borewell.The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011with required accessories including making connection suitable for Bore well. The job includes labour part of lowering ofriser pipe G.I./H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. 3.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound 162 21.13.1.2SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . For single phase Submersible / Monoblockpump. 2.0 HP to 3.0 HP (DOL starter) 163 (R-34/7.16.2.5)Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of high intensity grade sheeting exclusive of lettering, border and signs fixed over aluminium sheeting, 2mm thick fixed on a mild steel angle iron frame 50mmx50mmx6mm supported on mild steel angle iron post 75x75x6mm upto the top of sign board, length of post from bottom of sign board is 2.85m upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cmx45cmx60cm, 60cm below ground level as per approved drawing and as per MORTH specifications clause 801 Double angle post 120cm x 90cm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
28.
Housing Urban and Rular Development #10063632 Price Bid
Complete Tentage Arrangement On Ground 13-17 Panipat ( Haryana ) For Occasion Of Parkash Parv Utsav On 24Th April, 2022 - 1 Main Sabha Mandap ( 165 X 512 ) Installation Of German Made Fire Proof & Water Proof Structure With Clear Span Of 60Mtr Minimum Clear Height 18 To 20 Stable With Any Kind Of Wind Pressure. 2 The Ceilingand Sides Of Structure Covered With Theme Work Alongwith Printed Monogramme On The Good Quality Fabric As Per Direction Of The Officer-In-Charge. 3 Langar Hall ( 80 X 400 ) 2 Nos. Installation Of German Made Fire Proof & Water Proof Structure With Clear Span Of 30Mtr Minimum Clear Height 15 Stable With Any Kind Of Wind Pressure. 4 The Ceilingand Sides Of Structure Covered With Theme Work Alongwith Printed Monogramme On The Good Quality Fabric As Per Direction Of The Officer-In-Charge. 5 Stage Setup 120X 60 X 8Ft High Ms Structure ( Scaffolding ) With Double Ply On Top, Steel Railing , Carpet Flooring, Both Side 8F. Wide Landing And 12Ft Length , Steps Of 12 Inches Width And 6Inches Ht From 8 Ft Ht To 0 Ft- 4 Sets , Skirting Of The Stage Using Double Layered Aesthetic Looking Chunnat Cloth, Alongwith Spate Wooden Surface Stage Of 32 X 24 X 2 Feet For Palki Sahib With Thematic Design With Stage Masking Connected With Ram For The Proper Visibility And Excess To The Devotees Under The Direction Of Officer-In-Charge. 6 Air Conditioning ( 200 Tr ) Of The Stage ( Cooling As Per Weather Requirement . The Inner Units Of The Air Conditioner To Be Placed On The Periphery Of The Stage Concealed Under Flower Beds , With Steel Duct Mouth Fitted With Aesthetic Looking Nozzles As Per The Engineer Incharge. 7 High Quality Flower Decoration Bed On Stage 12 X 120 And Floral Work On Stahe Back Drop Flower Bunchs With Heavy Floral Work On Baba Ji Beed Sahib, As Per The Engineer Incharge 8 Sound System Line Array Speakers 16 Pair Array, 8 Pair Sub, Etc. With Amplifier, Mixer, Podium Mics, Stand Mics Cordless Mics, Etc As Per The Engineer Incharge For Appx. 70000 Pax. 9 Lights- Stage Lighting 50 Profile Spot, 120 Led Pars, All Necessary Cabling, Earthing I / C Connections With Technicians As Per The Engineer Incharge. 10 Providing And Fixing / With Stand60 Plasma With Live Streaming As Per The Engineer Incharge. 11 Led Screens With Live Streaming Inside 12 X 8 With Truss Hanging As Per The Engineer Incharge. 12 Mist Fans I / C Cabling And Necessary Connectios As Per The Engineer Incharge. 13 Soundproof Pedstal / Wall Fans / Ceiling Fan I / C Cabling And Necessary Connectios As Per The Engineer Incharge. 14 Commercial Dessert Big Cooler 15 Wooden Planks Flooring 19Mm Ply As Per The Engineer Incharge. 16 New Non Woven Synthetic Design Print Carpet / Plain Carpet ( As Per Design Approved ) As Per Actual Site Requirement And The As Per The Engineer Incharge. 17 Good Quality Mattress Covered With Clean Bed Sheet In All Area As Per The Engineer Incharge. 18 High Platform For Media, Console And Camera Finished With Woven Synthetic Carpet As Per The Engineer Incharge. 19 Golden Thematic Design Railing Of 4 Height And G.I. Pipe Barricadingcovered With Cloth In The Remaining Areaas Per Actual Site Requirement And The As Per Engineer Incharge. 20 Complete Event Theme Work For 400Th Parkash Parv Of Guru The Bahadur Sahib Ji Of Entire Venue I.E. ( A ) Front Elevation Façade Of 120 Rft 32Ft Ht. ( Made By Mdf, Ply, Iron Structure, Fibre, Carving Pillars Etc.. ) With Heavy Floral Work. ( B ) Stage Backdrop Work Look And Feel Of Gurudwara Sahib120 X 28 Ht ( Made By Mdf, Ply, Iron Structure, Fibre, Carving Pillars Etc.. ) With Heavy Floral Work. ( C ) 2 Gate Of 20 Feet For Media Lounge And Cm Lounge Look And Feel Of Gurudwara Sahib ( Made By Mdf, Ply, Iron Structure, Fibre, Carving Pillars Etc.. ) With Heavy Floral Work. ( D ) 100 X 200 Ft Passage With Heavy Indian Floral Work ( Orange And Yellow Marie Gold With Touch Of Green Leaves ) 21 Mojo Barricading With Minimum 4 Feet Height As Per The Engineer Incharge. 22 Temporary Security Light In Complete Function Area With Lighting Including Wiring Switch Gear Earthing Etc. Including Services Of Electricians As Per The Engineer Incharge. ( 1 ) Light Metal Halide 400W. 23 ( 2 ) Plug Points 5 Amp Or As Per Requirement 24 Flag :- Satin Cloth Fabric With Golden Printed Symbol With M.S. Pipe As Per The Theme Of The Event As Per The Engineer Incharge. 25 Exhibition Hall ( 82 X 240 ) Installation Of German Made Fire Proof & Water Proof Structure With Minimum Clear Height 18 To 20 Stable With Any Kind Of Wind Pressure. 26 The Ceilingand Sides Of Structure Covered With The Good Quality Fabric As Per Direction Of The Officer-In-Charge. 27 Exhibition Hall Side Wall Made By Mdf With Paint Finish With Spot Lights 28 200 Ton Ac Capacity With Cablings And Necessary Connections As Per The Engineer In Charge 29 Pa System For Audience Centre Fill Speakers For Audience Audio Mixer Complete With Wiring Etc. Including Followings As Per Requirement Of Site Having Following. Foot Monitors Top Delay, 36 Channel Mixture, Amplifier As Per Sound, Wires, Snake Cable, 2 Polidum Mic, 4 Cordless Mic, Corded Mic As Per Requirement, 2 Headset Mic I / C Operators & Required Staff At Least One Sound Engineer, Sound Technician, Sub Technician Etc. Note:- The Bidder Is Supposed To Have Visited The Site And Checked The Requirement Of Audio System For Complete Function Area I.E. Exhibition Hall As Per The Engineer Incharge. 30 Installation Of Fire Proof & Water Proof Structure For Chief Minister Loung-80 X 120 Sq.Feet With Air Conditioner, High Quality Interior, Furniture, Appropriate Lighting And Air Conditioning, Wooden Flooring With Dining Area With Non Woven Synthetic Carpet ( Green ) With Complete Furniture, Fabric Ceiling With Mdf Side Wall And Vip Toilet Van Etc. As Per The Engineer Incharge. 31 Installation Of Fire Proof & Water Proof Structure For Media Center 60 X 100 With Air Conditioner, High Quality Interior, Furniture, Appropriate Lighting And Air Conditioning, With Complete Furniture, Wooden Planks Flooring With Non Woven Synthetic Carpet ( Green ) , Drinking Water Etc. As Per The Engineer Incharge. 32 Tentage Truss For Kitchen Area & Washing Area With Side Wallkitchen Area ( 65 X 100 ) As Per The Engineer Incharge. 33 Serving Table With Frill And Covers As Per The Engineer Incharge. 34 Tentage Truss With Sides Cover Of ( 65 X 200 ) Each Which Will Utilized As Joda Ghar, Completewith Appropriate Arrangment Ofsteel Racks For Shoesas Per Direction Of The Officer-In-Charge . 35 Police Control Room Of Water Proof Tentage With Sides Cover As Per The Engineer Incharge.. 36 Pdg. Cctv / Hd For Surveillance Camera System Including Monitors Complete With Required Recording Equipments, Cabling Testing And Operation Including Required Operators To Cover The Complete Function Area Including Supply Of Recording On Cd. 37 Help Desk Of Water Proof Tentage With Sides Cover As Per The Engineer Incharge. 38 Lost And Found Of Water Proof Tentage With Sides Cover As Per The Engineer Incharge. 39 Development Of Toilet Compounds, 6 Nos. Toilets For Male ( 12 Wc + 20 Urinals + 6 Wash Basin ) 3 Nos. And For Female ( 20 Wc + 6 Wash Basin ) 3 Nos. For With Complete Water Supply And Houskeeping. 40 Ss Standing Wash Basin I / C Water Supply And Fitting 41 Urinals For Open Area Like Parking Etc. As Per The Engineer In Charge 42 Chemical Toilets As Per The Engineer In Charge 43 Toilet Vans For Media Lounge, Police Control, Medical Assitance Etc. As Per The Engineer Incharge 44 Providing / Installation Of 63Kva Gensetwith Load Distribution, Mains, Sub Mains, Suitable No. Of Earthing As Required At Site Ofi / C Cabling, And Fuel For Gen Set Including Services Of Operators, Mechanic Etc. For 1 Day At Various Locations Of Function Site As Per Requirement And Directions Of The Engineer Incharge For Smooth Running Of Entire Function. 45 Providing / Installation Of 125Kva Gensetwith Load Distribution, Mains, Sub Mains, Suitable No. Of Earthing As Required At Site Ofi / C Cabling, And Fuel For Gen Set Including Services Of Operators, Mechanic Etc. For 1 Day At Various Locations Of Function Site As Per Requirement And Directions Of The Engineer Incharge For Smooth Running Of Entire Function. 46 Providing / Installation Of 250Kva Gensetwith Load Distribution, Mains, Sub Mains, Suitable No. Of Earthing As Required At Site Ofi / C Cabling, And Fuel For Gen Set Including Services Of Operators, Mechanic Etc. For 1 Day At Various Locations Of Function Site As Per Requirement And Directions Of The Engineer Incharge For Smooth Running Of Entire Function. 47 Providing / Installation Of Loud Speekers In The Radius Of 2 Km. Area With All Necessary Connections On Main Roads For Relay Of Live Sound As Directed By Officer-In-Charge. 48 High Quality Sofa 2 / 3 Seater 49 Banquet Chairs With Covers 50 Centre Table 51 Installation Of 3M X 3M German Pagoda Structure With Side Cover & Front Façade At Various Locations Asdirected By Officer-In-Charge. 52 Installation Of 5M X 5M German Pagoda Structure With Side Cover 53 View Cutter With Structure & Cloth 54 Rope Barricading 55 Tin Barricading With Double Side Masking At 9Ft Ht. 56 Railing For Baba Ji Beed Sahib 57 Dustbin 80 Ltrs. 58 Providing And Fixing Of Fire Extigushar Abc Type 6 Kg. 59 G.I. Pipe Earth Complete With Salt And Charcol Etc.Note:- Rates Are Inclusive Loading, Unloading & Both Side Carriage And Will Not Be Paid Extra.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
29.
Public Administrative Department #9832565 AOC
Tender for Various Civil Work Of Ramai Samajbhavan At Bhankheda In Pr. No. 08-Dismantling brick masonry in lime or cement mortar and stacking the materilsas directed with all leads, lifts etc.-Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 3 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. 4 Providingsoling using80mm sizetrapmetalin15cm.Layer includingfilling voidswith Crushed sand/grit, ramming, watering etc. complete. 5 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/ quartzite/ gneissmetalforbedblocks, foundationblocksand suchotheritems includingbailingoutwater, Steelcentering,formwork,laying/pumping,compacting, roughening themifspecialfinishistobeprovided,finishingunevenand honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfully automaticmicro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 6 Providingsecond class Burnt Brick masonry with conventional/ I.S. typebricksincement mortar1:6insuperstructureincluding strikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete 7 ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 8 ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand rougheningthesurfaceifspecialfinishistobeprovidedandcuring etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 9 ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20 oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandings asper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish isto be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 10 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 11 Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetailed designsanddrawingsorasdirectedincluding cutting,fabricating, hoisting,erectingfixinginposition,Makingriveted/bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. 12 Providing andfixing colourcoatedZincalume (R)AZ150(min150 gms/sq.mt.totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallichotdipcoatedwithAluminium-Zincalloy(55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshall haveatotalcoatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center.The endribshall bedesignedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) 13 Providing internal cement plaster 12mmthick in single coat in cementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 14 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickin cementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surfaceofthebasecoatroughtoreceivethesandfacedtreatment6 to8mm thickin cementmortar1:4finishingthesurfacebytaking outgrainsandcuringforfourteendays scaffolding etc.complete. 15 Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. 16 Providingandapplyingprimingcoatonconcrete/masonary/ AsbestosCementplastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. 17 Providing and applying Royale Luxury Emulsion of approved make on internal wall surface asdetailedbelowScrappingforsurfacewith emerypaperandwipecleanforarea. wall primer withbrushby adding mineralturpentine oil by 8 to 10 % or water by 15 to 20% allowing to dryfor 6 to8 hoursAfter applying Asian / Berger / Nerolac / Dulex Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of4to6hoursofactivity.Scrapping withemerypaper andwipecleanApplying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 %or 65 to 70 % by roller. (With prior approval of S.E.) 18 Providingandapplyingtwocoatsofexterior weathershieldpaintof approved manufactureandofapprovedcolourtotheplastered surfaces including cleaning ,preparing the plastersurface ,applying primercoat,scaffoldingifnecessary,andwateringthesurfacefortwo daysetccomplete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary 19 Providingandapplyingtwocoatsoflead/zincbaseoil paint/ bituminiouspaintofapprovedcolour to new structural steel work andironworkinbuildingsincludingscaffoldingif necessary, cleaningandpreparingthesurfaceetc. complete.(excludingprimer coat). 20 ProvidingandfixinginpositionGypsum boardfalseceilingwith12.5 mm thickGypsum boards, screwed/fixedtotheunderstructureof suspendedG.I.Gridconstructedand suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum centerto centerdistanceof600milimetreperimeterchannelandintermediate channelsat maximumcentertocenterdistance1200milimetre galvanizedgridshouldbefixedto reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws.The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels.Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed inall respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. 21 Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. 22 Providingandfixinginposition.(asperI.S.1868/1982)Aluminium slidingwindowoftwotracks with rectangular pipehavingoverall dimension63.50x38.10x1.02mm atweight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/Running metre.Top andside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10mmatweight0.469Kilogram / Runningmetre.Andhandlesection 40x18x1.25mmatweight0.417Kilogram/Runningmetre.andtop section 40 x 18 x 1.25 mm at weight 0.417 Kilogram /Runningmetre.As perdetaileddrawingsandasdirectedbyEngineerincharge with allnecessaryAluminium sectionsfixturesandfasteningssuchasroller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. 23 Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete 24 Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panelswithoutventilatorasper detaileddrawingexcludingthedoorframe,stainlesssteel fixtures and fastening and finishing the wood work with oil painting 3 coats complete 25 Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12mmwithrollerwheelsconfirmingtogradeF.G.150fittedwithsnapheaded rivetsof minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clearspaceof150mmbetweentwo setsofcrossingswithholdfasts,stoppers,spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). 26 Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/candfixing inwallwith6 Nosofholdfastof12mm diabars500mm longincluding primer and oil painting etc, complete) frame size 60 mm x 100 mm . 27 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock, chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. 28 Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mm of8to10mmthicknessandconfirmingIS.15622- 2006(GroupBla)ofapprovedmake, shadeandpatternforflooring inrequiredpositionlaidonabedof1:4cementmorar including neat cement float, filling joints, curing and cleaning etc. complete. 29 Providing and laying vitrified matt finish tileshaving size 590 mm to 605 mm x to 605 mm of8to10mmthicknessandconfirmingIS.15622- 2006(GroupBla)ofapprovedmake, shadeandpatternfordadoand skirtinginrequiredpositionfixedin1:4cementmortar including neat cement float, filling joints, curing and cleaning etc. complete. 30 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 31 Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application of TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. 32 ProvidingandfixingP.V.C.Rainwaterpipesof110mmouter diameterandhavingwall thicknessof2.2to2.7mmconfirmingto I.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket withsolventcementandproperlyresting theshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. 33 Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternon bedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete. 34 ProvidingandfixingOrissatypewhiteglazedearthenware575mm waterclosetpan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 35 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jetandfittingincludingcuttingandmakinggoodto thewallsandfloorstestingetc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 36 Providing andfixing White GlazedEarthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall 37 Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32mm dia. P.V.C flush pipe withfittings andflushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall 38 ProvidingandfixingwhiteglazedearthenwareWashHandBasinof 45cmx30cmsize including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 39 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting andfixingofaccessories suchasinlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters 40 Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 41 Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 42 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 43 Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating,bend, connecting piece of UPVC pipe up to the outside face of wall,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 44 Providing and fixing 15 cm rigid PVC Nahanitrap including PVC grating ,bend,connectingpieceofUPVCpipeuptotheoutsidefaceofwall ,makingthegood damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) 45 Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 46 Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. 47 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 48 Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. 49 ProvidingandfixingC.P.TwowayBIBcockofapprovedmake continental including necessary sockets/union nut etc. complete. 50 Providing , laying and fixing ,jointingEco- drain 200 mm SN 4 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings suchabends,teestees,coupler etc,jointingwithrubberlubricantincludingnecessary excavation, trench refilling with selective excavated materialetc. complete. 51 Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hotdipzinccoatingincluding fabricating glazing withplain/obscuredglasspanes5mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. 52 Providing and fixing board displaying information, such as Name of work, Tender cost,NameofContractor,Workcompletionandliability periodetc,havingrectangularshapeof1.20mx0.90msize madeout18 gauge(1.25mm)thickmildsteelsheetpaintedwith onecoat ofZinc chromate stoving primer and two coats ofenamelpainton front side and greystoveenamelonbacksideandborder/messages/symbolsetc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3mmframewithproperlycrossbracedM.S.anglesofsize 35mmx35mmx3mmdulypaintedincludingTwoM.S.angleironpostsof size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x75cmincluding, excavation, refilling, transportation, and labour etc complete. Spec. Number As directed by Engineer in Charge 53 TransportationofMaterialobtainedfromdebriesofvarioussorts including necessary excavation / loosing including loading,unloading and conveying and disposing as directed.
Contract Date: Mar 18, 2026 Contract Value : 34.72 Lakh
Local Bodies No of Bidders 7
Maharashtra View Result →
30.
Defence #9629534 AOC
Tender For Repair/ Maintenance Of Internal Electrification And External Water Supply At Parundu, External Electric Supply At 4N Det And External Water Supply At 7N Detunder Ge Tirunelveli.; 1 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking creditand making good disturbed surfaces of walls, floors etc. 2 Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing cappingalong with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :- 3 One light point controlled by one switch 4 One fan point controlled by one regulator / switch 5 One 3 pin socket outlet 5 amps socket onindependent board 6 One 3 pin socket outlet 5 amps socket on Same Board 7 One light point controlled by two Nosof two way switches 8 One bell/buzzer point controlled by one push button 9 All description as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and as directed. 10 Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed. 11 Supply and fixing in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed. 12 Supply and fix in replacement switch piano flush type single pole one way 5 A 240 Volts complete all as specified and as directed. 13 Supply and fix in replacement switch Socketcombination 2 in 1,5 Amps Flush type 240 Voltscomplete all as specified and as directed. 14 Supply and fix in replacement switch Socketcombination 5 Amps / 16 amps, 5 in 1 flush type 240 Voltscomplete all as specified and as directed. 15 Supply and fix in replacementceiling rose3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed. 16 Supply and fix in replacement Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed. 17 Supply and fix in replacementStepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc completeall as specified and as directed. 18 Supply and fix in replacement Bell push flush type5 A 240 Volts complete all as specified and as directed. 19 Supply and fix inreplacement Modular switch 1 way 5A, 1 Module complete all as specified and as directed. 20 Supply and fix inreplacement Modular switch 1 way 16A, 1 Module complete all as specified and as directed. 21 Supply and fix inreplacement Modular bell push ,5 A, 1 Module complete all as specified and as directed. 22 Supply and fix inreplacement Modular Socket 5A-2/3 pin combined 2 Module complete all as specified and as directed. 23 Supply and fix inreplacement Modular Socket5A / 15A - 2 / 3 pin combined 2 Module complete all as specified anddirected 24 Supply and fix in replacement Modular fan regulator step type , 2 Module complete all as specified and as directed. 25 Supply and fix inreplacement Modular switch 2 way 5A, 1 Module, flush type complete all as specified and as directed. 26 Taking down carefully old unserviceable sub main wiring with aluminum /copper conductor cable 4/6 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. 27 Material and labour for sub main wiring with two run single core4 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor FRLS-H cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia/PVC casing capping 20 mm including conduit accessories all as specified and directed.Note: Three runs of 4 Sqmm cable and one run of 20mmconduit / casing capping will be measured as one unit length. 28 Material and labour for sub main wiring with two run single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cableas earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed.Note: Three runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length. 29 Material and labour for sub main wiring with four runs single core 6 sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor FRLS-H cableas earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed.Note: Five runs of 6 Sqmm cable and one run of 25 mm conduit / casing capping will be measured as one unit length. 30 Supply and fix in replacement Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC )complete all as specified and directed. 31 Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 4 way DB,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections,complete all as specified and as directed. 32 Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 8 way DBwith 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 33 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,SPN 12 wayDB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 34 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,TPN 4 wayDB ,415 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed. 35 Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,VTPN 4 wayDB with IP 43-IK 09 ,disconnecting electric connections, complete all as specified and as directed. 36 Supply and fix in replacementMCB SP 5 A to 32 A, B curve, 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 37 Supply and fix in replacementMCB SPN 32 Amps, C curve 10 kAincluding , Disconnecting electric connections,completeall as specified and as directed. 38 Supply and fix in replacementMCB TP25A - 63 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 39 Supply and fix in replacementMCB TPN 16 A- 32 Amps, C curve 10 kAincluding , Disconnecting electric connections,completeall as specified and as directed. 40 Supply and fix in replacementMCB TPN40A- 100 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed. 41 Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth stripof size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge 42 Supply and fix in replacement Lightning Protection Single point air termination aluminum rod 12mm dia 300mm long with base plate complete all as specified and as directed by the Engineer-in-Charge . 43 Supply and fix in replacement Test point terminal box made out of Gun metal or Phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screwscomplete all as specified and as directed by the Engineer-in-Charge . 44 Supply and fix in replacement Aluminium strip of 25x 3.15mm fixed with screws/ clamps / insulators for roof conductors and down conductors above ground level complete all as specified and as directed by the Engineer-in-Charge. 45 Supply and fix in replacement MCCB3 pole 415 volts25 to100 Amps, with rupturing capacity 16 KA complete all as specified and as directed 46 Supply and fix in replacement MCCB3 pole 415 volts125 Amps, with rupturing capacity 16 KA complete all as specified and as directed 47 Taking down geyser of any make/ type and any capacity after disconnecting the water and electric line connections from any height, bringing down to floor, dismantling the Geyser and overhauling by means of repair/replacement of the defective spares, cleaning externally and internally re-assembling the geyser, fixing in same position and testingfor satisfactory working etc complete.Note:Replacement of defective spares shall be measured and paid under relevant item separately. 48 Supply only Neon lamp indicator (Green and Red) 49 Supply only Bottom flange with inlet and outlet pipe (Apparatus plate) 50 Supply only Thermostat conforming to IS 3017 51 Supply only Flexible connection pipe set of two for cold and hot water 52 Supply only Heating element 2.0 KW 53 Supply Siphon assembly 54 Supply and fix Modular switch SP 1 way 16 Amp with indicator complete all as specified and as directed 55 Taking down ceiling fan 1200mm/1400mm sweep from any height and bringing down to floor, dismantling the ceiling fan and overhauling by means of replacing defective ball bearing, bushes, split pins, grease, packing, winding and cleaning externally, re-assembling the ceiling fan and checking, refixing in its position complete all as specified and directed.Note: (i) Rewinding, replacement of bearing and capacitors shall be measured and paid separately.(ii) All other petty repairs used for this work shall be included in the quoted rate. 56 All as per item No.55 but for exhaust fan 300mm including replacing of rusted nut and bolts complete all as specified and directed. 57 All as per item No.55 but for exhaust fan 450 mm including replacing of rusted nut and bolts complete all as specified and directed. 58 Supply and fix ball bearing suitable for any sweep ceiling fan complete all as specified and directed. 59 Material and labour for rewinding with super enameled copper wire including varnishing, drying and connection complete all as specified and directed. 60 Material and labour for painting of ceiling fans at site with synthetic enamel paint by spray painting including filing cavities with filler in one coat after cleaning dust complete all as specified and directed. 61 Supply and fixing exhaust fan heavy duty 250mm sweep plastic body 900RP, 230V, 50 Hz with louvers, cutting the wall and fixing all as specified and directed.(Note Old exhaust fan to be deposited after taking down to MES store) 62 Supply and fix in replacement louvers for exhaust fan of any sizeincluding taking down old unserviceable louvers and removing the material for taking credit complete all as specified and directed. 63 Supply and fix in replacement Condensor 2.5 to 4 mfd for Ceiling/exhaust fan, including taking down old unserviceable material for taking credit complete all as specified and directed. 64 Supply and fixin replacementFlame proof switch socket &plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earthcomplete all as specified and directed. 65 Supply and fixin replacement Switch flame proof rotary type with termination box in LM6, 16A, single pole 250Vcomplete all as specified and directed. 66 Supply and fix in replacement LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completeall as specified and directed 67 Supply and fixing LED light fitting in replacement 1x9W/1X10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 68 Supply and fix in replacementLED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 69 Supply and fix in replacement LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed 70 Supply and fix in replacement round shape 6 watt (6 inch) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 71 Supply and fix in replacement round shape 12 watt (8 inch) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 72 Supply and fix in replacement square shape 300x30mm size 15 watt220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 73 Supply and fix LED1x4 feet, 40Watt, recess mounted light fitting environment friendly, new generation, aesthetically designed ultra modern with high transmitive diffuser suitable for indoor spaces complete all as specified and directed 74 Supply and fix LED in replacement vertical mounting integral highbay/medium bay in hangar ceiling at 10 metre height LED IP65lumnnaire,luminous flux 15000 luminous efficacy 150 lmW, IK 08 surge protection luminaries surge protection level until 4kV along with necessary chain, hooks to hold the bolt and hang the light fitting complete all as specified and directed 75 Supply and fix in repairs LED Security light fitting 35 W LEDcomplete with all accessories internally pre wired and connecting up with twin / three core flexible copper conductor cable of suitable size from ceiling rose to fitting etc, including necessary bracket complete all as specified and as directed. 76 Supply and fix in replacement LED light fitting 2x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including all accessoriescomplete all as specified and as directed. 77 Providing comprehensive annual maintenance periodical/preventive maintenanceincluding annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specificationby providing one AC/Refrigeration mechanic including replacement ofcomponents as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-(a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil.(b) Cleaning of air filters, indoor unit grillSupply and fixingilters through air blower.(c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period.(d) Check and replace the refrigerant pipe once in a contract period or as and when required.(e) Check and repair the minor electrical fault in incoming supply.(f) Check and replace the water PVC pipe.(g)Replacementof faulty spares/components(h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional(Each Job contains 3 Complaints) 78 Supply only the following new items for 1.5 / 2.00 Ton CapacitySplit type AC including testing and commissioning etc complete all as directed. 79 Capacitor 36/45/50 MFD. 80 Air filters. 81 Outdoor fan motor 82 Indoor fan motor 83 Indoor blower 84 Copper condenser coil unit (for A/C) 85 Indoor motor capacitor 2.5 MFD. 86 Outdoor fan motor capacitor 3 to 6 MFD 87 Non return valve (For gas top up charging) 88 Remote control suitable forinverter model Split AC. 89 Electronic components for repairs to PCB 90 PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . 91 PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . 92 Copper pipe of size 1/2 for suction line with foam insulation 93 Copper pipe of size 1/4 for discharge line with foam insulation 94 Swing Motor for indoor unit 95 Supply and fixPVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for AC complete all as specified and as directed. 96 Supply and fixMetal plug top for AC 97 Supply and fixing compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :- 98 Split type AC 1.5 Ton capacity. 99 Material and labour for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPMCB, complete all as specified and directed by Engr-in charge. 100 Supply and fix in repairs LED Security light fitting 25 W LEDcomplete with all accessories internally pre wired and connecting up with twin / three core flexible copper conductor cable of suitable size from ceiling rose to fitting etc, including necessary bracket complete all as specified and as directed. 101 Supply and fix in replacement flat panel 36 watt 2x2 feet 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed 102 Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type ofsoil, complete all as specified 103 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified 104 Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge. 105 Spreading of riddled earth obtained from trenchesfor cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured) 106 Supply and laybricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to thelength of the brick; complete all as specified and directed. 107 Supply and fix in replacement MCCB4 pole 415 volts63 Amps, with rupturing capacity 16 KA complete all as specified and as directed 108 Supply and fix in replacement MCCB4 pole 415 volts100 Amps, with rupturing capacity 16 KA complete all as specified and as directed 109 Material and labour in replacement of GI pipe light grade of size 80mm diafor protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed by the Engineer-in-Charge . 110 Servicing of high mast light control gear suspension system with stainless steel wire rope guage and double drum winch with luminaries mounting arm pulley assembly complete all as specified and directed by Engr-in-charge. 111 Supply and fixing in replacement LED flood light 150Watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP6 protectionwith impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge. 112 Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables 3.5 core 70 sqmm, armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland and lugs on both end termination including laying, connecting to various switches inpanel board, testing and commissioning complete all as directed & as specified. 113 Supply and fixing L bus bar box outdoor type made up of MS sheet 3mm thk of size 600x500x300mm CPRI approved with supporting angle of size 50x5xmm, 800mm long with nut, bolts and washers of suitable size for fixing on ground with PCC 1:3:6 mix, 20mm aggregate for foundation providing Aluminum bus bar 400m long and 40x5mm thick, 04 nos with supporting insulators and colour coded PVC sleeves including necessary bottom plat whole for entry o cables complete all as specified and directed. 114 Supply and fix in replacementGI tubingmedium gradeincluding provision of necessary fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories laid in trenchesall as specified and directed by Engineer-in-Charge of following bore sizes:- 115 (a) 20 mm bore steel tubing 116 (b) 25 mm bore steel tubing 117 (d) 40 mm bore steel tubing 118 (e) 50 mm bore steel tubing 119 (f) 80 mm bore steel tubing 120 Supply and FixingGI tubingmedium grade including provision of fittings like Tee,Bend,Socket,Elbow, Short pieces connectors, plugs, unions, etc and accessories on walls/roofs all as specified and directed by Engineer-in-Charge of following bore sizes:- 121 (a) 20 mm bore steel tubing 122 (b) 25 mmbore steel tubing 123 (d) 40 mm bore steel tubing 124 (e) 50 mm bore steel tubing 125 Monthly testing of potable water samples for checking fitness for drinking purposeat the district water testing lab complete all as specified and directed. 126 Monthly testing of raw water/potable water samples for checking fitness for domestic consumption at the district water testing lab complete all as specified and directed. 127 Supply and fixing of gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2,for iron pipe of following sizes complete all as specified and directed. 128 (a) 20 mm bore 129 (b) 25 mmbore 130 (c) 32 mmbore 131 (d) 40 mm bore 132 (e) 50 mm bore 133 Supply and fix in repairbrass float valve, ISI marked high pressure with polythene float and fly nut complete, screwed of following size / bore including necessary GI fittings such as elbow, reducer, nipple complete all as specified and directed. 134 (a) 20 mm dia 135 (b) 25 mm dia 136 (c) 40 mm dia 137 (d) 50 mm dia 138 Supply and fix Pressure gauge 5 dia, 0 to 14 Kg/cm2 range fixing on delivery pipe of pump set and removing existing defective pressure gauge and taken as credit complete all as specified and as directed. 139 Supply and fixsluice valves flanged end, cast iron body, flanged and drilled and non rising type stainless steel spindlewith nut, long body, class P N 1.6, conforming to IS 14846 of 2000 for following sizesincluding all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed by Eng-in-Charge of following sizes. 140 (a) Sluice Valve, Class PN 1.6, 63mm dia 141 (b) Sluice Valve, Class PN 1.6, 80mm dia 142 (c) Non Return Sluice Valve, 80mm dia 143 Supply and fixFoot Valve screwed / flanged including necessary fittings like connectingflanges of following sizes. 144 (a) Foot Valve 50 mm dia 145 (b) Foot Valve63 mm dia 146 Replacement of GI flange having holes(ISI marked) suitable for 40mm bore pipe including jointing material such as rubber gasket bolt units and washers etc in place of unserviceable all as directed. 147 All as per item No.106 above but Suitable for 50 mm bore pipe 148 All as per item No.106 above but Suitable for 80 mm bore pipe 149 Replacement of GI union of both end lock nut screwed with leak proof washer connected to existing GI tubing of 20mm bore completeall as directed. 150 All as per item No.109 above but Suitable for 25 mm bore pipe 151 All as per item No.109 above but Suitable for 40 mm bore pipe 152 All as per item No.109 above but Suitable for 50 mm bore pipe 153 Material and labour forby scraping / cleaning with wire brushes to remove the old painting from pump, motor, coupling guard, MS common base frame and painting with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer as specified below here in after for pump sets:-(a)Motor and pump - Smoke Grey colour (b) Coupling guard and motor air grill - Post office Red colour.(c)Common base frame - Black colour (d)Suction line and delivery line in side pump house - Navy blue colour for fresh water pipe lines. 154 Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 1 / 2 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for main repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items.(ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch A but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below(iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. 155 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 156 Supply onlyBall bearings (drive and non drive end)Make 157 Supply onlyElectro dynamically balanced bronze impeller 158 Supply onlyImpeller Key 159 Supply onlyWater Seal 160 Supply only Terminal connection with terminal box 161 Supply only Condensor suitable capacity / MFD 162 All as per item No 114 herein before but pump set of capacity 3 HP Note: The cost of spares shall be paid under relevant items given below as Supply only. 163 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 164 Supply only Ball bearing (Drive and Non drive end) 165 Supply only Cooling fan blade 166 Supply only Cooling fan cover with suitable screws 167 Supply only Terminal box with terminal connection 168 Supply only Electric dynamically balanced bronze impeller 169 Supply only Shaft mild steel 170 Supply only Gun Metal bush 171 Supply only Gland cup with bolts and nuts 172 Supply only Flange drilled suitable size with bolts, nuts and washersincluding rubber gasket 173 Supply only Air cock nozzle brass 174 Supply only Shaft coupling 175 Supply only chlorine test kit. 176 Supply only impeller key 177 Supply only water seal 178 Supply only Condensor of suitable capacity/MFD 179 Supply only Calcium Hypochlorite 65% to 70% Chlorine content in granular form (Calcium based Granular disinfectant for water treatmentof drinking water ). Packed in 45 Kgs each Drum. Make:- Sree Rayalaseema Hi Strength Hypo Ltd.(Brand :- PURI CHLOR)or approved by NMPT Committee of E-in-Cs Branch.Note:- The contractormust submit the NSF Certificate of the product, FSSAI Registration and COC (Certificate of Compliance) in original from manufactures by All India Authorized MES Distributor for each batch of product delivered indicating. Including chemical analysis report by all India authorized MES Distributor. Product must have min. 65% Chlorine Contents suitable for Human Consumption. 180 Material and Labour Cleaning valve chamber of any size by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of valve chamber all as directed by Engineer-in-charge. 181 Material and labour for disconnectany size/ model of pump set from the foundation bed to carry out minor repair work such as greasing, gland rope packing, nut & bolts, washers and flanged and complete the correctrotational alignment for smooth functioning all as directed by the Engr-in- charge. 182 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 1 HP-5 HPincluding taking out old unserviceable all as directed. 183 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 2HP-5 HPincluding taking out old unserviceable all as directed. 184 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for sluice valve 63/80mm diaincluding taking out old unserviceable all as directed. 185 Removal of dust and cleaning the Earth pitand washingthe same, applying one coat of white wash , writing the letters such as for Pump set Numberas required at sitewith enamel paint of black colour on pit cover complete all as specified and as directed. 186 Material and labour for Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit, 25mm dia/PVC casing capping 32 mmand conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed.Note: Four runs of 4sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length. 187 Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified 188 Demolition of cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge. 189 Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed. 190 Material and labour for preparation of new steel surface and applying two coats of approved colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 191 Material and labour for attending breakdown complaints like no water supply in service tank, pipe line leakages etc and also removing air lock in OTM/Single living accommodations with help of required tools and man power with items like GI fittings of any size/dia, union, elbow, tee, bend, nipple, socket etc including excavation upto 1.0 cum if required for rectification of leakage of GI pipe all as specified and directed.Note:-(i) Rate of items like union, elbow, nipple ,coupler, bend socket shall be included in the unit quoted rate.(ii) Rate of excavation upto 1 cum shall be included in the unit quoted rate. 192 Taking down defective mono block / Centrifugal pump setfrom foundation by opening of coupling and foundation bolts and transporting to workshop for repairing and reassembling after servicing and overhauling complete with oiling/greasing, lubricating the parts including repair / replacement of worn out parts and replacement of base foundation nuts and bolts and re-installing ,necessary electrical connection and testing for satisfactory performance complete all as specified and directed by Engineer - in - Charge.for electric driven pump set of 5 HP capacity Note:- (i) The rate quoted for this item shall includes labour charge only for main repair and replacement of defective/UNSV spares/accessories. Spares are to measured and paid separately under subsequent items.(ii) Cost of other minor items/spares such as nut, bolts washers, gaskets,etc which are not covered under Sch A but required for effective functioning of the plant shall be deemed to included in this item. (ii) The cost of spares shall be paid under relevant items given below(iii)In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. Note: The cost of spares shall be paid under relevant items given below as Supply only. 193 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 194 Supply only Ball bearing (Drive and Non drive end) 195 Supply only Cooling fan blade 196 Supply only Cooling fan cover with suitable screws 197 Supply onlyTerminal box with terminal connection 198 Supply only Electric dynamically balanced bronze impeller 199 Supply only Flange drilled suitable size with bolts, nuts and washers including rubber gasket 200 Supply only Air cock nozzle brass 201 Supply only Shaft coupling 202 All as per Slitem No : 152herein before but defective open well submersible pump set of capacity1 HP/2 HP1 Ph, 240 Voltsincluding taking up the pump set fromopen well/UG sump after disconnecting the electrical and pipeline connection, completewithout any damage to the pump set or thepipes and transporting to workshop including repair/replacement of worn out parts, servicing and overhauling complete with oiling/greasing, lubricating the parts and reassembling and painting of submersible pump set with motor with two coat of synthetic enamel paint over a coat of red oxide after clearing and scrubbing and shifting back to bore well, lowering commissioning and testing on full load complete all as specified and directed by Engineer-in-charge.Note: In case of any damage to thepipes during the time of removal of the pump set ,contractor shall be responsible for repairing the same without any extra cost to the government. 203 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 204 Supply only Thrust bearing 205 Supply only Electro dynamically balanced bronze impeller 206 Supply only Gun Metal bush 207 Supply only Gland Cup with bolts and nuts 208 Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket 209 Supply only Shaft Mild steel 210 Supply only Rotor sleeve 211 All as per Slitem No 152 herein before but pump set capacity 5 HP . Note: The cost of spares shall be paid under relevant items given below as Supply only. 212 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 213 Supply only Thrust bearing 214 Supply only Electro dynamically balanced bronze impeller 215 Supply only Gun Metal bush 216 Supply only Gland Cup with bolts and nuts 217 Supply only GI Flange drilled suitable size bolts, nuts, washers and rubber gasket 218 Supply only Shaft Mild steel 219 Supply only Rotor sleeve 220 All as per Slitem No 152 herein before but Non- clogging submersible pump set capacity 7.5 HP . Note: The cost of spares shall be paid under relevant items given below as Supply only. 221 Rewinding of motorcoil complete as per IS-396 of 1953 using super enamelled copper wire ofadequate gauge and weight including replacement of all insulation material and terminal lead for power supply and other petty items required for making motor functional. 222 Supply only Thrust/ball bearing 223 Supply only Electro dynamically balanced bronze impeller 224 Supply only Cooling fan blade 225 Supply only terminal box with terminal connectors 226 Supply only Shaft Mild steel 227 Supply only Gun Metal bush 228 Cleaning the internal and external surface of UG sump / Static water tankof capacity up to 10000 gallons and well by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall and top surface of sump including writing particulars such as capacity of sump, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed 229 Cleaning the internal and external surface of Shallow well of size 4.50 mtr dia. and 6 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed 230 Cleaning the internal and external surface of deep Open well of size 7-10 mtr dia. and 10-15 mtr depth by scrapping/brushing and removing all silt dust etc from walls, floors, clean with water and bleaching powder and applying one coat of lime wash to all internal surfaces and complete removal of sand,dust.dirt and other unwanted coatings from the exterior wall surfaces by suitable means and painting with weather proof oil bound distemper to complete side wall of shallow well including writing particulars such as depth of shallow well, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting topipe lines and valves with approved colour (Pipe line exposed above surface) of any size complete all as directed 231 Cleaning the internal surfaces of Over Head Tank at 45 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 100000 Litres capacity 232 Cleaning the internal surfaces of Over Head Tank at 15 m height / staging by scrapping down/brushing and removing all silt dirt, algae etc from walls, floors, washing/ cleaning with water and applying one coat of white wash to all internal surfaces of walls and ceilings complete including writing particulars such as capacity of OH tank, date of cleaning and due date of cleaning etc using white paint on black back ground with height of letter to match with the existing size including painting to incoming and outgoing pipe lines and valves/valve chambers with approved colour (Pipe line exposed above surface) of any size complete all as directed all as directed by Engineer-in-charge for 15000 Ltr capacity. 233 NOTE FOR SL ITEM NO 188 TO 192 -1. T & P for dewatering UG Sump / Static Tank has to be arranged by the contractor. Rate quoted is inclusive of material and labour required for dewatering. Nothing extra shall be paid separately. 2. All the operations should be executed by trained workers and technicians, properly dressed along with gum boots, safety harness to work as per the direction of Engineer in charge. Contractor shall bring suitable fittings to connect cleanout pipe and suitable length pipe using cleanout facility if available and operational without damaging water tank. Nothing extra shall be paid separately. Contractor shall be responsible for complete cleaning, suction, disposal activity and thereafter. Any damages to water tank during cleaning operation shall be repaired by the Contractor with no cost to MES. Contractor shall ensure and implement safe working conditions for his laborers during execution , all necessary safety measures and harness shall be used before taking-up work. Suitable lighting and ventilation should be provided by the contractor before cleaning of covered tanks. Agency shall be solitary responsible for the lapses in the safety during the work and allied compensations. Nothing extra shall be paid separately, etc. complete as per direction of Engineer In-charge. 234 Supply and fix Three phase direct online starter, suitable for 1 HP - 5 HP Pump/motor including necessary electrical connections and taking down old unserviceable all as directed. 235 Supply and fix Three phase direct online starter , suitable for7.5 HP Pump/motor. including necessary electrical connections and taking down old unserviceable all as directed. 236 Supply and fixSingle phase direct online starter, suitable for0.5 - 2 HP Pump/motor including necessary electrical connections and taking out old unserviceable all as directed. 237 Supply and fix single phase preventer 3 phase 415 voltsincluding taking out old unserviceable all as directed.. 238 Material and Labour Cleaning rain water collection well (depth 3 mtr: meant for collection of rain water and pumping away the collected water by submersible pumps of 7.5 HP during rainy season) by removing all unwanted particles such as mud, sand, dust, dirt, decayed leaves etc. and applying two coats of white wash to all internal and external surfaces of collection well including painting of submersible pumps 7.5 HP and connected pipe lines ( 2 Pump sets in each rain water collection chamber) with synthetic enamel paint of approved colour all as directed by Engineer-in-charge. 239 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for pump size 2HP-5 HPincluding taking out old unserviceable all as directed. 240 Supply and fix Gland rope (graphite rope ) (size 1/2,1/4,3/4) suitable for Sluice valves 63/80mm dia including taking out old unserviceable all as directed. 241 Supply and connecting flat three core, PVC insulated industrial Flat cable for submersible motor, 4 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 242 Supply and connecting flat three core, PVC insulated industrial flat cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 243 Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type ofsoil, complete all as specified 244 Material and labour for rendering 10mm thickin cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified and as directed by the Engineer-in-Charge. 245 Material and labour for providing cement concrete 1:2:4 Type B0 using 12.5mm graded aggregate as in copings, complete all as specified and as directed by the Engineer-in-Charge. 246 Material and labour for fixing valve chamber cover in replacement, fabricated from MS sheet 3mm thickness, fixing Angle at all sides, with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement complete all as specified and as directed by the Engineer-in-Charge.
Contract Date: Feb 07, 2026 Contract Value : 32.56 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
31.
Heavy Industries and Public Enterprises #9514337 Price Bid
Tender For Supply And Installation Of Street Light High Mast And Decorative Street Light Poles In Remaining Dark Zone At Ia. Sikandrabad With 03 Year Amc. - Part-A High Mast 06 Nos. decorative light and LED Tiranga. Supply & Fixing of 16 Mtr. High Mast shaft of approved make with rising system hot dip galvanized in side & out side dip, heaving pole sheet thickness 3 mm top dia minimum 150 mm bottom dia 360 mm base plate 32 mm thick suitable for wing velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as had frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia double drum winch, including making suitable foundation as per manufacture drawing, site regiment along with foundation bolts, nuts washers, anchor plates etc. complete in all respect.Make Bajaj / Cromptonetc with approved UPSIDA prescribed Logo 2 Supply & fixing of factory wired integral200 W LED floodlight luminaries with die cast aluminium housing built with driver set confirming to IP 66 protection (with 5 years of warranty) complete in all respect,Cat.-AA(Bajaj/Philips/Wipro or equal brand approved in UPPWD) 3 Supply and fixing 25A TPN capacity of automatic street light cubicle control panel painted with anticorrosive alkali and acid proof paint consisting of time switch TSO 100 series with ML-3 contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. complete in all respect. 4 Supplying and laying of 16 sq.mm 4 core aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top complete in all respects. (Havells/Polycab/Grandley or equal brand as approved by E/I.) 5 Supply & Laying of63 mm HDPE pipe ISI marked along with all accessories like socket,bend,couple etc. confirming to IS 14930 Part II complete with fitting and cutting,jointing etc in existing treanch. including cost of material,labour and T&P. 6 Supply & fixing of 16 sq. mm 4 core brass nickle plated compression gland for PVC insulated cable complete in all respect. 7 Supply & fixing of 16 sq. mm 4 core size pin or plan type copper tin plated socket/lug to cable leads with insulated tape and making connection to point complete in all respect. 8 Supply & fixing of 50 mm dia GI pipe B classfor climbing up the cable from ground to over head line LT pole complete withGI fitting including material,labour and T&P as per SIDC Sch item No. 25A.1(LS 6.0 mtr for each HM) 9 Supply & fixing of 100 mm dia GI pipe B classfor climbing up the cable from ground to over head line LT pole complete withGI fitting including material,labour and T&P as per SIDC Sch item No. 25(LS 6.0 mtr for each HM) 10 Supply & fixing MS clamp made out from 50x6mm MS flat for securing GI Pipe/HDPE with ST pole. 11 Providing & fixing 32mm x6mm G.I. earth strip on surface or in recess including cost of GI saddle/Al. Alloy/cadmium/PVC fastener etc.plated iron screw etc. as required for connections. (5M for each) 12 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect as per drawing UPPWD Sch. No. 701 13 Supply & fixing of LED light Strip with driver on street light pole at two no. 24 meter entrance roads including cost work T&P men and material complete in all respect. The LED strip should be in tri Colour as red, white and green (each colour 6 mtr.respectively.) With 01 Year warranty against defects/damage/missing. 14 Supply & Fixing of 4.0 Mtr. long Decorative Ornamental Pole duly PU (Poly Urethane) Painted made of high tensile GI Steel Pipe.The Top section of pole must have Cast Aluminum Embellishments through out thelength. Base Plate size 350x350x12mm with PCD of 350mm. Foundation bolts set of M16x450mdeoorative pole made of Mild Steel with a total height of 4mtr aboveground level with single arm bracket of ornamental decorative street light 60W and predefined laser cut pattern in house laser machine in the top portion of the bracket of the pole as per design. Pole bottom base section shall be 220x220x1000mm, 2mm thiclmess column with three side predesigned laser cut and illumination. the surroundings in 20W with notioeable mode, top section pole of 90x3000x3mm & top bracket with laser cut pattern design one side of IOOOmm to hold the street light of 60W as per shared drawing. The base plate of pole shall be of size 350x350x10mm. Provision for inside termination box with 4way connector & Inoa 6 AMPS MCB for local isolation. Light fixture shall be made of aluminium of size 600x580mm of street light distribution of 60W for area lighting. Light output of souroe is more than 110lm/ watt, CRl>80, SPD 4k, operating voltage 140-270V. Fitting is IP65, wired with Branded LED and constant current driver. Proper thermal management for longer life of fixture. Led burning of 50,000 hours. The pole is coated with UV stabilized powder coat and cured in in-house powder coating machine. The decorative pole is suitable for outdoor lighting application. Pole light is complete in all aspects with all aooessories & foundation bolts. mx 4 Nos made of EN8 grade steel should be used only for erection. A lockable door of suitable size should be provided at bottom section for termination and connection with backelite sheet and connector, MCB, foundation bolts, Bottom dia-350mm up to 1200mm height from base plate.Top section dia 90mm & toleranoe as per IS code or approved by engineer in charge, Supply and fixing of decorative 60 Watt LED Post top indirect/suspended light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect with 5years warantee.Technical specification, make & profile as approved by engineer in charge.CAT AA. 15 Supply and wiring of sub main with 02 nos.of 2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of work as directed E/I 16 Supply and laying of 10 sq.mm 4 corealuminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. (Cable laid in Ex. DWC Pipe) (as per UPPWD approved make list) 17 S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (c) 25 sq. mm 18 S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated, underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer- incharge as per UPPWD sch. no. 503 (j) 25 sq. mm 3.5 core 19 S/F of palm or pin type copper tin plated cable socket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (c) 10 sq. mm 20 S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated, underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connected with the earth as per direction of Engineer- incharge as per UPPWD sch. no. 503 (b) 10 sq. mm 4 core 21 Part-2 Street Lights : Supply & fixing 90W LED Street light having die cast aluminium body and diffuser with driver set suitable for 90 Watt confirming to IP 66 protection complete in all respect with surge protection device. Minimum CAT AA (Crompton/Philips with 5 year warrenty against defects,damaged & missing)Make: Crompton/Philips/Bajaj/Wipro 22 Supply & fixing 130 W LED Street light having die cast aluminium body and diffuser with driver set suitable for 130 Watt confirming to IP 66 protection complete in all respect with surge protection device. Minimum CAT AA (Crompton/Philips with 5 year warrenty against defects,damaged & missing)Make: Crompton/Philips/Bajaj/Wipro 23 Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-39 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 24 S/F of street light junction box made of SMC material complete with 4 way terminal block, cable gland etc. 25 S/F of 6 Amp to 32 Amp SP MCB (10KA) B curve 26 Supply & fixing 32mm dia,1.20M long GI bend pipe with 02 nos. clamp of 50x6mm MS Flat suitable for fixing street light on ST pole including cost of men and T&P. 27 S/E of D clamps of 38mm X 6mm flat iron for wall/ roof type service bracket with bolts, nuts etc, complete in all respects including painting with aluminium paint 28 Supply & fixing of 100 x 110 mm shackle insulator /100 x 80 mm pin insulator including G.I. Bolts/ spindle nuts etc.Complete in all respect. 29 Supply, sagging & tensioning of 6 SWG GI earth wire including cost of material, men and T&P 30 Supply & fixing insulated piercing connector set suitable for ABC cable/Insulated Conductor including cost of material,men and T&P. 31 Suppy,laying & drawing of3x1.5 Sq mm PVC insulated copper cable for Street/flood lights connection in existing pipe/surface/air as required including cost of material, men and T&P.(Havells/Polycab/Grandlay) 32 Supplying and laying of 25 sq.mm 3.5 core aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and on top complete in all respects. 33 Supply and laying of 16 sq mm 2 core aluminium conductor PVC insulated , armoured , served ,sheathed cable 1100 v grade in existing pipe/surface/pole etc. (Havells/Polycab/Grandley/Gloster) 34 Supply & fixing of 25 sq. mm 3.5 core cable socket/lug with insulated tape in cable termination complete in all respect. 35 Supply & fixing of 16 sq. mm 2 core cable socket/lug with insulated tape in cable termination complete in all respect. 36 Supply & fixing of 25 sq. mm 3.5 core brass nickle plated compression gland for PVC insulated cable complete in all respect. 37 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete inall respect. The armouring of the cable shall be properly connected with the earth as per direction of EngineerIn charge. 38 Supply & fixing 40A TPN capacity of automatic street light cubical panel painted with anti corrosive alkali and acid proof paint consisting of digitel/time switch TSO 100 series with ML-3 contactors,HRC fuses/MCB/MCCB/ isolating switch metering instrument & instrument box with CTs etc or as directed . Design & material will be approved by Engineer in charge. 39 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(Approved make) 40 Providing & fixing 32mm x6mm G.I. earth strip on surface or in recess including cost of GI saddle/Al. Alloy/cadmium/PVC fastener etc.plated iron screw etc. as required for connections. 41 Supply & Laying of 90 mm dia (OD-90 mm & ID-76 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend,couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sand cushioning andprotective covering etc. complete in all respect 42 Supply & fixing of 50 mm dia GI pipe B classfor climbing up the cable from ground to over head LTlinepole/Metering point complete withGI fitting including material,labour and T&P. 43 Supply & fixing of 100 mm dia GI pipe B classfor climbing up the cable from ground to over head LTlinepole/Metering point complete withGI fitting including material,labour and T&P. 44 Supply & fixing MS clamp made out from 50x6mm MS flat for securing GI Pipe/HDPE with ST pole. 45 Supply and fixing of MS/GI clamp as per design suitable for fixing shackle insulator, made out for 50x6mm M.S. Flat including nut, bolt & washer. 46 Supply & erection of stay set at 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19 mm 600 mm double screw tightener, 7/3.5 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in all respect 47 Supply , Sagging & tensoning of overhead line with insulated ACSR weasel conductor including binding etc complete in all respects. 48 Supply,sagging,tensioning,jointing and binding of ACSR Weasel conductor including cost of aluminium tape binding wire and jointing sleeves complete in all respects including materiaI,men an T&P for proper completion of work . 49 Fabrication, supply and fixing of work information board in M.S. frame made by 50mm dia Square Pipe of Stainless steel grade SS-304 & 16 mm thick base plate with back supporting of bracing by MS flat of 25x6mm and 2.85 Mtr long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green color with white letters as required and shall be fixed at a height of 1.2 Meter from ground by providing 0.45x0.45x0.60 Mtr cement concrete stone pad as per drawing enclosed.The Borad Should be installed within 07 day of signing of Contract Boand.) 50 Part-3 AMC of work :S&F single unit Aviation obstruction blinking RED LED Light with making connection etc. complete in all respect on top of the as per direction of engineer incharge. (CAT AAA) as per UPPWD Sch item No. 409 51 S&F junction box made from MS Sheet of 200x300x100mm duly painted, complete with cable glands, connector etc. suitable for 24 Nos. Flood lights connection.ED-II(39)/Dt: 01.06.2022 52 S&F Annealed tinned Copper flexible soft PVC/Rubber insulated trailing cable of 4.0 sq.mm 5 core in full length suitable upto 30 Mtr height. ED-II(39)/Dt: 01.06.2022 53 Supply and fixing of male-female plug socket for 16 meter high mast lighting system complete in all respects.ED-11(39)/Dt: 01.06.2022 54 Rewinding/Repairing of 1.5 HP 3 Phase 415V Burnt AC Power Tool Motor with B-Class super enamel Copper wire including dismantling and re-fixing at Original place 55 Supply & top-up gear oil in winch machine by opening gear box including cost of material, men and T&P. 56 Oiling & greasing of SS wire rope set and other moving parts by lowering down.re-hoisting of lantarn carriage including cost of material, men and T&P 57 S&F double drum 750 Kg winch machine suiable for high Mast Light including making/modification proper arrangement for installation in existing shaft. 58 Supply & fixing Gl lantern carriage made from 50NB ERW Class B Pipe suitable for 16/20/30 mtr lighting fixing including lowering & hoisting of system and all other associated work along with cost of men, material and T&P. 59 S&F of stainless steel grade AIS1316 steel wire rope set 6-8 mm diameter in full length suitable for 12/16/20/30 Mtr height on existing winch machine including making/modification proper arrangement for installation in existing machine. 60 Supply & fixing 3-Phase, 63A 415V Power Contractor ML-3 type or equel for Automatic Street & High Mast Control Panel in cluding cost of Connection, men and T&P. 61 Supply & fixing Astronomical time switch L&T/Siemens/C&S or equel brand including cost of connection, material, men and T&P. 62 S&F of 63 amp. 4 pole MCB (10KA cat B) for control panel complete in all respects 63 S&F of 40 amp. double pole MCB (10KA cat B) for control panel complete in all respects 64 S&F of 100 Amp. T.P. Isolator CAT B 65 S&F of 80 to 100 Amp 4 pole MCCB (16 KA) ThermalMagnetic release 66 Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-39 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 67 Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC Insulated and PVC sheathed/XLPE aluminium conductor 25/35/50 sq.mm 3.5 core cable of 1100 v grade complete rates 68 Supplying and laying of 16 sq.mm 4 core aluminium conductor PVC insulated, armoured, served, sheathed cable 1100 V grade at a depth of 750 mm below ground level with existingG.I./M.S./DWC or Hume pipe in road crossing or along the wall complete in all respects. (Havells/Polycab/Grandley or equel brand as approved by E/I.) 69 Supply and wiring of submain with 2 number 2.5 sqmm FRLSH PVC insulated single core multistranded copper conductor cable in existing conduit complete in all respects complete. 70 Providing operating cum maintenance staff of the entire street light network for routine maintenance of street lighting system, administrative, site office and staff colony etc including dismantling & re fixing of other street lights of UPSIDA with travelling expenses etc. (Electrician cum supervisor 01 nos, electrician 01 nos, helper 03 nos) 71 Supply & fixing jointing sleeve for Insulated ACSR Weasel conductor for cost of all material, men and T&P 72 S&F of 6-32 amp. double pole MCB (10KA cat B) for control panel complete in all respects. 73 Supply & fixing Sheet steel enclosure for SP/DP MCB with neutral link and earth terminal 74 Painting letters (Pole No.) 2.5cm up to 8.0 cm size complete on Street light Pole/Panel/Other electrical properties under UPSIDA including cost of all material, men and T&P (To be done after 1 year) 75 Cleaning & spray painting of ST bend pole and power ST pole (above 10 meters) with one coat of red oxide primer and two coat of alum. paint/PU paint as per direction of Engineer incharge including cost of all material, men and Hydraulic crane, other T&P. (Burger/Nerolac/ Asian make) (To be done after 1 year) 76 Trimming of tree branch around the street light pole/ST pole/Central Varge for proper illumination & proper disposal of tree branch collecting on trolley or similar moving item including cost of men, trolley, T&P etc. (1000 x 3 Year) 77 Strengthen of Other ST pole foundation by providing new concerting including cost of all material men and T&P. 78 Dismantling & re-grouting of street light/Steel tubler (upto 12 Mtr long) Tilt/sick bend pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 04 Nos. support of 65x65x6mm or higher size MS angle in suitable length with the help of welding/cutting as per technical specification. 79 Providing pole earthling of an existing pole by inserting MS Rod 2000x2500mm in vertically ground level and connecting the pole with the help of 6 SWG GI wire including cost of all material, men and T&P. in industrial area as per UPSIDA/UPPCL Technical specification. 80 Hiring Charge of 80-100 feet expandable street light repairing hydraulic lift, capacity 300 Kg including cost of operator, mounting vehicle and fuel etc. (8 Hrs x 4 day x 36 Month) 81 Cost of material spares, wire, fuse, small accessories, alum. lug upto 16 sqmm, small cable gland, insulation tap, plastic tie, screw, nut & bolts,old cloth, cleaning spray and other small associated required for up gradation work etc.,
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
32.
Housing Urban and Rular Development #9493817 Technical Bid
Tender For Kareli - Nurulla Road to Askari Market Road Block C and Block D Housing Scheme and Nurulla Road from Mahavir Chauraha to Karamat Ki Chowki near Sasur Khedari River and also till the connecting road - Clearing grass and removal of rubbish upto a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201. 3 Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 60 metres as per instructions of E-I-C. (By Mechanical means). 4 i) Cement Concrete 5 ii) Reinforced cement concrete/ R.B. 6 Dismantling of flexible pavements and disposal of dismantled material up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical specification Clause 202. Bituminous / Granular Courses (By Mechanical means) 7 Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap. 8 Removing all type of Hume Pipes and Stacking within a lead of 1000 metres including T&P, Earthwork and Dismantling of Masonry Works. 9 (i) Up to 600 mm dia 10 Removal of telephone / Electric poles / Street light / Lamp post including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately 11 Disposal of moorum/building rubbish malba/ similar unserviceable, dismantled or waste material by mechanical transport Including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. Note- Item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 12 Dewatering using 10HP to 70HP diesel engine pump set including Hire charges, cost of Diesel, Engine oil, pump operator, labor charges, conveyance of pump set and fuel to site and back, loading, unloading and any other incidental charges etc., complete. (Hire charges for Diesel Pump set for 10 HP) 13 [B] Bill No. 2 - Earthworks 14 Excavation for road work in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and leading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections and transporting to the embankment location within all lifts and lead upto 1000m 15 Removal of unserviceable soil including excavation loading and disposal but excluding replacement by suitable soil which shall be paid separately as per clause 305 16 i) Lead upto 1000 M 17 ii) Lead upto 8000 M 18 Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out construction of shoring and bracing, removal of stumps and other deleterious matter dressing of sides and bottom, backfilling the excavation earth to the extent required and utilizing the remaining earth locally for road work. 19 Mechanical Means (Depth upto 1.5 m) 20 i) Excavation 21 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 22 [C] Bill no. 3 - Development of Carriageway 23 Stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: Providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with IRC-SP-72-2015 , IRC-37-2012 & 2018 and IRC SP 89 (part II) 2018. Cementitious additive @ rate of minimum 5 - 7% and CCS/CS additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. The additive spreader shall have variable working width sufficient to cover whole pavement lane. The in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. The resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per IRC 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. The entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. The tandem roller be followed by Pneumatic Tyre Roller. The minimum unconfined compressive strength (UCS) of stabilized sub base/ base should be 4.5 to 7 MPa after 7 / 28 days of curing as per IRC-SP- 72-2015 , IRC-37-2012 & 2018 . Also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The gradation mixes and materials should be as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The train of equipments to be used are binder spreader- water Tanker- Additive Truck- Recycler- Padfoot Roller (20 Tonne) + Single Drum Compactor- Grader- Tandom Roller- Pneumatic TyreRoller (20 Tonne) 24 SAMI LAYERProviding and laying Stress Absorbing Membrane Interlayer (SAMI)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of claues 703-3, laid over a tack coat of paving grade Bitumen 80- 100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement Surface. 25 Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. (Tack Coat on Bituminous surfaces ) 26 Providing and laying 40mmthickBitumencarpete(B.C.) with 100-120 TPh hot mix plant producing and average output of 75 tonege par hour using crushed aggregates of specified grading premixed with bitumen binder(VG-30) @ 5.40% of mix as per MOST specification clause. etc all comp of work. 27 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from aggregat aggregate natural sources, Portland Pozzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall. be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 28 M.S. (TOR steel or plain) in plain work such as RCC or RB work including binding for proper shape and including supply of steel and its wastage bend, hooks and authorized overlapping shall be measured and including cost of binding wire. Excluding GST (SOR-504). 29 [D] Bill No. 4 - Pedestrian Infrastructure (Footpath) 30 Sand Filling in Foundation Trenches as per Drawing & Technical Specification and as per direction of Engineer-in-charge. (including beneath all paver blocks, cobble areas for levelling purpose, etc.) 31 Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. (PCC below all paving area, Kerb Channel, Road edge kerb, Table top, Property edge beam) 32 Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 33 i) For Grading-I Material 34 Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications, PCC Grade M30using batching plant transit mixer & manual placing(80 mm thickness) r & manual placingand giving broom finish. (PCC with broom finish thickness 80 mm) 35 Providing and laying 75mm thick M-30 grade batch mix cement concrete and Applying stamping finish to the top surface of freshly laid plain/ reinforced cement concrete of specified grade in porticos, sidewalks, driveways, pool decks and open yards as per direction of the Engineer-in-Charge. The process shall include the following:-The concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. The approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. The approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the hole surface to be stamped is completed within the time while concrete is in plastic stage of setting.After stamping, the curing shall be done as per manufactures specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per theequirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface.The construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (Cost of concrete for flooring is not included in this item which shall be paid separately.) 36 80 mm thick C.C. paver block of M-35 grade with approved color design and pattern. 37 Supply and fixing of Tactile indicators made from SS-304 grade stainless steel. Warning Tactile indicator Shall be installed on the walking surface in a raised grid pattern of dots or stud. Minimum 36 studs to be placed in 300X300 mm area. Dimensions - 35mm Outer Dia x25mm Inner Dia, Stem Dia 8mmx12mm, Weight - 28grm.All the indicator will be installed into correctly drilled holes and place any suitable adhesive, All the indicators shall be aligned property, all complete as per direction of Engineer-in-charge. 38 Supply & fixing of Tactile indicators made from SS-304 grade stainless steel. Directorial Tactile indicator shall be installed on walking surface, consisting of a series of raised bar/strip. Min 4 bars/strip to be placed in direction perpendicular to distance of travel in 300X300 mm area. Dimensions-280mm L x 35mm W x 4.5mm, Stem Dia 8mmx12mm, Weight - 250grm All the indicator will be installed into correctly drilled holes and place any suitable adhesive, All the indicators shall be aligned property., all complete as per direction of Engineer-in-charge. 39 Providing and laying Tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colors and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge 40 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR-11.20) 41 Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. (Saucer drain along the road edge, Curved Kerbs at Property Entry/Exit, Curved Kerbs at side roads) 42 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 43 CC Grade M20 using batching plant transit mixer & manual placing all complete as per direction of E-I-C. 44 [E] Bill No. 5 -Parking 45 Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 (by mix in place method) 46 i) For Grading-I Material 47 Supplying and filling in plinth with sand under floors/in trenches, including watering, ramming, consolidating and dressing all complete with material (from source to site), labor and T&P etc. required for proper completion of the work. (Including Royalty). 48 Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days and giving broom finish. (PCC) 49 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved color design and pattern. 50 [F] Bill No. 6 -Cycle track 51 Nil 52 [G] Bill No. 7 - Traffic Signs, Markings and Other Road Appurtenances 53 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer[1]in-Charge.(Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 54 Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply and fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrile) or HIPS (High-impact Polystyrene) or Acrylonitrile Butadiene Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall support a load of 13,635 kg tested in accordance with ASTM D4260. The Reflective panels shall consist, of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face. Lenses shall be moulded of methyl methacrylate conforming to ASTM D788 of equivalent. The slop or retro-reflecting surface shall preferably ba 5+/.5 degree lo base and the area of each retro -reflecting surface shall not be less than 13.00 $Q.cm. the marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the Engineer . In addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. In case the markers are, displaced , damaged . get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer , at his own cost. The rate shall include all materials, labor, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge, 55 RPM With Shank 56 Solar Power Road Marker The solar studs shall be made of aluminum alloy and polycarbonate material which shall be absolutely weather resistant and strong enough to support to load of 13,635 kg tested in accordance with ASTM D4280. Its color may be white, red, yellow, green or blue or combination as directed by the Engineer. Its water resistance shall meet the requirements of IP 65 in accordance with IS: 12063:1987 category 2 for the protection against water ingress. The dimensions of solar studs shall not be less than 100 mm * 100 mm * 10 mm. It shall have super bright LEDs so as the provide long visibility from a distance of more than 800 m. Its flashing rate shall not be less than 1 Hz. Its should be able to give the prescribed performance in the temperature range of -40 degree C to +55 degree C. Its life shall be not less than 3 Years. The rate shall include all material, labor, equipments, fabrication, transportation erection, installation and incidentals all complete as per direction of the engineer-in-charge 57 R.CC work (1:1.5:3) (M-20) with cement course sand &20mm the stone grit including all complete cement concrete with cement sand &20mm gauge stone Grit with the proportion of (1:1.5:3)including all complete the work (MORTH RA-12.8 C, Case-II) 58 M.S. or Iron work plain or Tor for RCC work including cutting, bending, rivetting or welding etc. where necessary. Excluding GST (S.I.No-504) 59 Painting Two Coats on New Concrete Surfaces - Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces 60 M.S. or Iron work of heavy sizes section such as Trusses, built up gates, record racks, roof work, gates etc. Including rivetting or welding where necessary. Excluding GST (S.I.No-503) 61 Painting of M.S. Grill with enamul paint etc all complete work. (S.I. 15.15 new item no.) 62 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. 63 Providing and fixing of retro- reflectorized cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting type-IVvide clause 801.3, 2mm thick aluminum sheeting, 1.5 mm thick supported on mild steel angle iron post 75mm* 75mm *6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cm* 45cm*60 cm, 60 cm below ground level as per the approved drawing. The retroreflective sheeting shall be tested for a certificate of having the sheeting coefficient of retro reflection, daytime, color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoors weathering and its having passed these tests shall be obtained from international/ government laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should be also obtained from Indian condition within 3 years of launching ofproduct by the manufacturing abroad. Alternatively, a certificate conforming to ASTM specification (D4956-09) on Artificial accelerated weathering requirement from a reputed laboratory in India can be accepted provisionally. In such a situation , the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per IRC 67:2012 . Legends, letters, numerals, and borders etc. should be as per MoRT&H specification 801.3.7. Proof of the same in form of government reports shall be uploaded while quoting tender. 64 90 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 65 60 cm equilateral triangle with diffinitation plate size (20cm x 60 cm) 66 60 cm circular with diffinitation plate size (20cm x 60 cm) 67 80mm x 60mm rectangularwith diffinitation plate size (20cm x 60 cm) 68 60 mm x 45 mm rectangularwith diffinitationplate size (20cm x 60 cm) 69 60cm x 60cm square with diffinitation plate size (20cm x 60 cm) 70 90 cm high octagon 71 Direction and place Identification signs up to 0.90 sqm size Board Providing and erecting direction and place identification retro-reflectorized sign as per IRC-67 made of high intensity grade sheeting The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/ Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends, letters, numerals and borders etc. should be as per MoRT&H specification No-801.3.7. Sheet fixed over aluminum sheeting 2 mm thick with area not exceeding 0.9 sqm. Supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60cm., below ground level as per approved drawing, complete. 72 Direction and place Identification signs with size more than 0.90 sqm size BoardProviding and erecting direction and place identification retro-reflectorized sign as per IRC-67 made of high intensity grade sheeting The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime color and luminance, shrinkage, flexibility. liner removal, adhesion, Impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends, letters, numerals and borders etc. should be as per MoRT&H specification No-801.3.7. Sheet fixed over aluminum sheeting 2 mm thick with area exceeding 0.9 sqm. Supported on a mild steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing, complete. 73 Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per IRC :67 74 Brick Masonry Work in Cement Mortar 1:4 (1Cement: 4 Coarse Sand) in Foundation complete with Cement Concrete Bricks procured from C&D Waste Recycling Plant Baswar excluding Pointing and Plastering, as per Drawing and Technical Specifications. 75 Struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 finerness modulus.SOR 2022 SI no574 76 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 sand)and as per direction of Engineer in charge. 77 Finishing walls with ready mixed Premium acrylic emulsion paint (company depot tinted) having Volatile Organic Compound (VOC)less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali, & fungal resistance, dirt resistance exterior paint of required shade with silicon additive(for painting wall, street furniture) New work (two or more coats applied @1.43 liter/10sqm over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm) 78 Supplying and Fixing of cast iron antique style bench having weight of sides not less than 72 kg (36 kg each) fitted with fibre rectangle strip (should not be less than 50 mm X 25 mm and 1.6mm thick. Length of Bench should not be less than 6 ft (end to end of castiron support). 79 [H] Bill no. 8 - Utility and street light cabling 80 Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.(PCC below pipe of Storm water, Sewer, Water, Inspection chamber for storm water, telecom chamber, power chamber and sewer) 81 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete (Storm water, sewer) 82 600 mm dia RCC pipes 83 Providing of 7- Way 40mm Multi Ducts with solid permanently solidly lubricated Silicone in inner layer for ICT fiber cables conforming to ASTM F 2160, ASTM D 2444 and /or equivalent Indian standard. External Sheathshall be in Orange Colorand shall be free from visual defects like blisters, shrink holes,flaking, scratches, groove lines & surface roughness. The color of the 7 nos. PLB HDPE ducts shall be Green, blue, yellow, Brown, violet, Grey , Red for differentiation. Outer sheet thicknessshall be 1.2mm +/-0.2mm. The inner surface of the multi channel ducts shall be spirally ribbed & shall be of a configuration for faster installation of cables. Wall thickness(mm) of each of the ducts Excluding rib height shall be 2.9mm +/- 0.3mm. ISO Requirements- ISO 9001, 14001, 18001, complete as per specifications and directions of Engineer-in-charge. (7 way multi utility duct for OFC) 84 Supply of HDPE pipe of size 110mm for distribution system conformingn to latest/ relevant I.S. 4984/1995 Specifications with all jointing materials and specials conforming to latest /relevant I.S. specifications including F.O.R. destination and all taxes and insurance etc. with loading, unloading and Carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of Engineer-in-charge.110mm dia HDPE pipe PN-6 class PE-100 85 Supply of HDPE pipe of size 63mm for distribution system conformingn to latest/ relevant I.S. 4984/1995 Specifications with all jointing materials and specials conforming to latest /relevant I.S. specifications including F.O.R. destination and all taxes and insurance etc. with loading, unloading and Carting up to site of work, also including specials for these pipes and lowering them into the trenches and laying true to alignment and gradient and jointing etc. complete (including testing of pipe lines and cutting of pipes for making up the length but excluding the cost of trenches) all complete as per instructions of Engineer-in-charge.63mm dia HDPE pipe PN-6 class PE-100 86 RCC Grade M20 using batching plant transit mixer & manual placing ( Side wall, bottom slab for all inspection chamber i.e. storm water, telecom, power, sewer, water) 87 Supply and installation on site - Recessed double seal ofwith a clear opening of750*750 mm DI manhole cover and frame(material- ductile iron grade 500/7) of class B125 having minimum load capacity 125 KN Load as per EN124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by Engineer in chargedesign approved by Engineer in charge. 88 Supply and installation on site - Recessed double seal ofwith a clear opening of750*750 mm DI manhole cover and frame(material- ductile iron grade 500/7) of class D400 having minimum load capacity 400 KN Load as per EN124-2, the top cover( should have 2 no. of keyholes ) as per the design approved by Engineer in chargedesign approved by Engineer in charge. (storm water) 89 Supply and fixing Gully Grates RED 048 GRH – 300* 750mm D.I. GULLY GRATE & FRAME IN D400 LOAD CLASS , as per BS EN 124 Black Bitumen Paint, all complete as per direction of Engineer-in-charge. 90 Constructing rcc rectangular type manholewith a floating coat of neat cement, foundation concrete 1:6:12mix (1 cement : 6 coarse sand : 12 graded brick bats 40 mm nominal size), and making necessary channel in cement concrete of M-25 grade finished with a floating coat of neat cement, all complete as per standard design and instruction of E-I-C. 91 Restoration of water pipeline in case of damage 92 [I] Bill no. 9 - Horticulture / Landscaping works 93 Trenching in ordinary soil up to required depth including removal and stacking of serviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clods etc. and making the trenched area with designed mounds, paths and sitting spaces etc. to proper levels by filling with earth or earth mixed with manure and properly watering complete work in required topography as per drawing & specifications. 94 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 95 Supplying and stacking at site dump manure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 96 Mixing earth and manure in specified proportion or as directed. 97 Rough dressing the trenched ground including breaking the clods. 98 Fine dressing the ground 99 Spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 100 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 101 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of officer in charge 102 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 103 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. 104 Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 105 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 106 Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 107 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 108 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 109 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 110 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 111 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 112 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 113 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size ofPoly bags & as per direction of the officer-in-charge. 114 Providing and stacking of Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 115 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 116 Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 117 Providing and fixing MS iron tree guard 60 cm dia and 2 metre high above ground level formed of 4 Nos (25 x 6 mm) and 8 Nos (25 x 3 mm) vertical MS riveted to 3 Nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia and 30 mm long bolts including painting two coats with paint of approved brand over a coat of priming, complete in all respects. 118 Street Light Works (Excluding GST) 119 Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect 120 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. Cat: AAA 121 Supply and laying of 16 sq.mm. 4 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 122 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. 123 Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia38mm terminal Dia 12 mm ,outer GIpipe of 16 SWG and inner GI pipe of 12 SWG withHot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. 124 Making Connection of each street light by S/L 1.5 sqmm FRLSH copper wire complete as per Direction of engineer in charge. 125 Supply & fixing of 9 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length each ) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 126 Supply & Laying of 63 mm Dia (OD-63 mm & ID- 51 mm Nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers, etc. conforming to IS 14930, part II complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 127 Supply and fixing for automatic street light cubical control Juction Box painted with anti-corrosive alkali and acid proof pait consisting of 6 Amps MCB (B - Curve) complete in all respect 128 Supply and fixing of 16 sq.mm plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 129 Supply and fixing of 40 Amp. capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 130 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 131 Supply/ erection of surface mounted decorative pole 4500 mm long having Base plate 300x300x12 mm with the bottom dia 139 mm upto 1 mtr long with the thickness of 3.6 mm and the top dia is 76 mm upto 3.5 mtr. Log. Decorative pole made out of Galvanized iron tube with cast Aluminium embellishments. The poles are painted with Polyturetnane paint. The pole have service window at the bottom on the pole for housing the MCB and terminal strips and as per attached drawings. 132 S/F of Single Arm decorative Bracket 100 mm long made of Cast iron/ Aluminium embellishments painted with Polyturetnane paint. 133 Supply of LED decorative drop down light made of aluminium housing fitted with polycarbonate diffuser having 500 mm dia with 70 w. 134 Supplyandlayingof aluminiumconductorPVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core 135 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 40 A TPN 136 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 16 sq. mm 137 Supply & Laying of 63 mm Dia (OD-63 mm & ID- 51 mm Nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers, etc. conforming to IS 14930, part II complete with fitting and cutting, jointing, etc. direct in ground (75 cm below ground level) including excavation & refilling the trench but excluding sand cushioning & protective covering etc, complete as required. 138 Supply and Laying 6 swg G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required. 139 Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia38mm terminal Dia 12 mm ,outer GIpipe of 16 SWG and inner GI pipe of 12 SWG withHot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. 140 Part - B Utility Shifting (Including GST) 141 Converstion of LT Overhead Line by Underground LT Line 142 LT XLPE insulated cable of size 3.5x400 sqmm. 143 LT XLPE insulated cable of size 3.5x240 sqmm. 144 LT XLPE insulated cable of size 3.5x150 sqmm. 145 LT XLPE insulated cable of size 3.5x70 sqmm. 146 9 mtr long stp 147 HDPE Pipe 140mm dia PEB0, PN-6 148 HDPE Pipe 120 mm dia PEB0, PN-6 149 HDPE Pipe 75 mm dia P880, PN-6 150 Aluminium Crimping Lugs 400sqmm 151 Aluminium Crimping Lugs 240sqmm 152 Aluminium Crimping Lugs 150sqmm 153 Aluminium Crimping Lugs 70sqmm 154 6 SWG G.l. wire for earthing along cables. 155 Cable end termination using total double compression brass glands and crimping type Cu. Thimbles for 3.5x400 Sqmm. LT Cable 156 Cable end termination using total double compression brass glands and crimping type Cu. Thimbles for 3.5x240 Sqmm. LT Cable 157 Cable end termination using total double compression brass glands and crimping type Cu. Thimbles for 3.5x150 Sqmm. LT Cable 158 Cable end termination using total double compression brass glands and crimping type Cu. Thimbles for 3.5x70 Sqmm. LT Cable 159 MAIN LT PANEL AT SUB STATION- 400 KVA (Type A-2)lncomer- 1 Set of 800 Amp. TP MCCB with Spreader & Extended handleMetering on lncomer - 1 Set of Digital Ammeter with ASS- 1 Set of Digatal Voltmeter with VSS- 1 Set of LED type Phase lndicating Light (22.5 mm.)with Control MCBsOutgoing- 6 Set of 250 Amp. TP MCCB with Spreader & Extended handte( 5 Nos. + 1 No. for capacitor panel)- 2 Set of 100 Amp. TP MCCB with Spreader & Extended handle 160 MAIN LT PANEL AT SUB STATTON- 250 KVA (Type A-2) lncomer- 1 No. 630 Amp. TP MDO ACB with Inbuilt MPR Release with I onToff tnai.ating LightMetering on lncomer - 1 Set of Digital Ammeter with ASS- I Set olDigital Volt-meLer wirh VSS- 1 Set of LED type Phase Indicating Light (22.5 mm.J with Control MCBs Outgoing - 5 Set of 250 Amp. TP MCCB with Spreader & Exrended handle- 2 Set of 100 Amp. TP MCCB with Spreader & Extended handle flnstallation ofLT Distribution Boards for LT underground system (Type A,B&CJ) 161 Supply , installation, testing & commissioning of outdoor type feeder pillar panetto be made of 2 mm CRCA sheet and covers will be j.6mm CRCA sheet dulypowder coated paint with 300 amps Al. busbar. (Type-B2)lncomer - 250 Amp. TP MCCB - 1 No.Outgoing - 63 Amp. TP MCCB - 5 Nos.lnstallation of LT Distribution Boards forLT underground system (Type-A, B & C) 162 Outdoor type feeder pillar panel to be made of 2 mm CRCA sheet and covers will be 1.6mm CRCA sheet duly powder coated paint with 300 amps Al. busbar. [Type-B3] Incomer - 100 Amp. TP MCCB - 1 No. Outgoing - 63 Amp. TP MCCB - 4 Nos.lnstallation of LT Distribution Boards for LT qnderground system [Tvpe-A, B & Cl 163 Lockable distribution boxes of size 450X400mm with bus bar 100 Amp. TPN to feed upto 10 houses (Type C) 164 XLPE LT Service armoured Cable for single phase,2x6 sq. mm.(pVC armoured Consumer Service Cablel 165 XLPE LT Service armoured Cable for single phase,2x10 sq. mm.(pVC armoured Consumer Service CableJ 166 XLPE LT Service armoured Cable for three phase,4x10 sq. mm.[pVC armoured Consumer Service Cablel 167 XLPE LT Service armoured Cable for three phase,4x1.6 sq. mm.(pVC armoured Consumer Service Cablel 168 XLPE LT Service armoured Cable for three phase,4x25 sq. mm.(PVC armou[ed Consumer Service Cable) 169 PVC PIPE 32 MM DIA 170 PVC PIPE 50 MM DIA 171 Electronic KWH Meter 1PX2W with Box. For single phase consumer 172 Electronic KWH Meter 3PX4W Static meter with Box.For three phase consumer 173 carriage , Laying of 3.5Cx400 sq.mm size LT XLPE insulated cable underground in HDPE pipe size 140 mm dia. 174 carriage, Laying of 3.5Cx150/240 sq.mm size LT XLPE insulated cable underground in HDPE pipe size 1.20 mm dia. 175 carriage ,Laying of 3.5CX70 sq.mm size LT XLPE insulated cable underground in HDPE pipe size 75mm dia. 176 Painting of STP incuding paints [2 ltr red oxide and 2 Ltr Alluminum paint for each pole.l 177 Grouting of ST pole 178 CARTAGE , ERECTION AND DISMENTLING CHARGES 22% OF MATERIALS COST 179 Conversion of 11KV Overhead/Underground Line by 11KV Line Underground 180 11 Kv cable size 3x185 sq.mm XLPE 181 STP 11M-IS 410 SP-55 182 G.l pipe 4 dia 183 TOP channel 100x50x2240 mm 184 HDPE Pipe 160 mm dia PE 80, pN-6 185 Service clamp O/S 186 Clamp for fixing pipe to pole 187 11 Kv cable jointing kit size 3x185 sq.mm XLPE O/D 188 11 Kv cable jointing kit size 3x185 sq.mm XLPE S/T 189 Earthing complete. 190 M.S. Nut & Bolt with washer 191 Bracing angle 65x65x6x2700 mm with clamp 192 Stone Pad 193 Number plates with Clamp 194 Danger board & clamp with bolts & nuts 195 Stay complete 196 G I Barbed Wire 197 carriage , Layrng of 3X185 sq.mm size 11 KV XLPE insulated cable underground in HDPE pipe dia 160 mm. 198 Painting of STP incuding paints (2 Itr red oxide and Z Lt. Allrn inrm pal,1t for each pole.) 199 Grouting of ST pole 200 Grouting of Stay set 201 CARTAGE , ERECTION AND DISMENTLING CHARGES 22% OF MATERIALS COST 202 Conversion of 33KV Overhead/ Underground Line by 33KV Line underground 203 Cable Al. 3x300 sq.mm. XLPE 33 KV 204 STP 11M-IS 410 SP-55 205 G.l pipe 6 dia 206 M.S.Top channel 100x50x2240 mm 207 HDPE Pipe 200 mm dia PE 80, pN-6 208 Service clamp O/S 209 Clamp for fixing pipe to pole 210 Bracing angle 65x65x6x4300 mm with clamp 211 33 KV cable jointing kit 3X300 Se MM outdoor 212 33 KV cable jointing kit 3X300 Se MM Straight Through 213 Earthing of pole by MS earthing rod of 2OX25O0 mm & 6 SWG earthr.ng wire etc. 214 M.S. Nut & Bolt with washer 215 Number plates with Clamp 216 Danger board & clamp with bolts & nuts 217 Stay complete (Stay rod 15X1800mm, Stay wire 5 KG,, Stay clamp, Boult & nut rvith grouting 218 Daner bqard barbed wire includin jumpering 219 carriage , Layrng of 3X300 sq.mm size 33 KV XLPE insulated cable underground in HDPE pipe dia 200 mm. 220 Painting of STP incuding paints (2 Itr red oxide and Z Lt. Allrn inrm pal,1t for each pole.) 221 Grouting of ST pole 222 Grouting of Stay set 223 CARTAGE , ERECTION AND DISMENTLING CHARGES 22% OF MATERIALS COST 224 INSTALLATION OF 250 KVA TRANSFORMER ON DP FOR THE SHIFTING OF 3 No. 250 KVA. 9 No.400 KVA & 3 NO. 630 KVA TRANSFORMER 225 STP 11M-IS 410 SP-55 226 MS channel 100x50x2240 mm 227 SERVICE CLAMP FOR ROUND POLE 228 M.S. BOLT AND NUTS OFF SIZE WITH WASHER 229 L.T. CABLE 3.5OX4OO SO M 230 LTXLPE Insulated,Unarmoured Aluminium Singlc Corc Cable,1x240sq. mm.Sizc 231 LT XLPE Insulatcd,Unarmoured Aluminium Singlc Core Cablc,1x400 sq. mm.Size 232 EARTHING OF 250 KVA T/F WITH G.I. PIP[ 233 EARTHING ROD COMPLET. 234 1 1 KV D.O. FI]SE SETS 235 1 1 KV TPMO 236 D.D. WIRE 70 qs mm 237 250 KVA T/F 238 L.T. CUBICAL B0X complete 239 L,T. CABLE 3.50X240 SQ MM 240 STAY SET COMPLETE, 241 ALUMINIMUM LUG 70 SQMM 242 ALUMINIMUM LUG 240 SQMM 243 ALUMINIMUM LUG 400 SQMM 244 PVC TAPE 245 T/F BUSHING CONNECTOR OF COPPER STRIP 246 Labour , Cartage & Errection Charges and Dismentaling of existing T/F 247 Dismentling and Cartage from site to store Charges 7% (Other Misclenous Charges)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
33.
Housing Urban and Rular Development #9483563 Technical Bid
Tender For Work Of Street Lighting From Culvert Of Road No. 8 To Ssp Office In Anand Vihar Housing Scheme - Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & backfilling and Required T&P completee in all respect.. SOR SI NO 641/18 (make - philips / crompton / bajaj / utkarsh) 2 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. SOR SI NO 501/18 (make - gloster / havells / universal) 10 sq. mm 4 core 3 16 sq. mm 4 core 4 Supply and fixing of plain or pin type copper tin plated cable socket( lug ) to the cable leads, insulating with tape and making connectionetc. complete in all respect as per direction of the Engineer- Incharge. SOR SI NO 504/1810 sq. mm 5 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 65 and above Protection complete in all respects.SOR SI NO. 1424/18 CAT AAA (make - philips / crompton / bajaj / havells / eveready) 6 Supply and Wiring of submains with two nos. of 2.5 sq. mm.FRLSHPVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge. SOR SI NO. 289/18 7 S&F of 6 Amp to 32 Amp. MCB (10 KA) C Curve CAT A. SOR SI NO 1002/18 CAT AAA 8 S/F of 2.5mt. long 20mm dia MS earth rod with 6 SWG GI earth wire, nut, bolt & washer etc all complete. PR 9 Supply and burying of 600mm x 600mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG G.I. wire in 15 mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal / coke and salt at least 150 mm thick alround etc. as per directions of Engineer-in-charge complete in all respect. SIN-703/18 10 Supply and fixing of following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.SOR SI NO 807/18 (make - L&T / siemens / havells)40 A TPN 11 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. DSR S.I. No. 14.15.1/2022(make - dure line / line duct)63 mm dia (OD-63 mm & ID-51 mm nominal) @247 X 0.85212=210.47 12 S&F of 63 Amp. 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. CAT -B PWD SOR S.I. No. 316/2018(make - L&T / siemens / havells)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Uttar Pradesh View Result →
34.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
35.
Heavy Industries and Public Enterprises #9472378 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area, Amausi (Part-1) District Lucknow Under Aiim-2 - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 13 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 16 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 18 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 19 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 21 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 22 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 24 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.(as per UPPWD approved make list) 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 26 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 29 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 30 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 31 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(as per UPPWD approved make list) 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 34 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 35 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(as per UPPWD approved make list) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete asrequired.(as per UPPWD approved make list) 37 Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.(as per UPPWD approved make list) 38 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 39 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 44 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.)(as per UPPWD approved make list) 46 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 47 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 50 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 51 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 52 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 53 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 54 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 55 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 57 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 59 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 60 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 62 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 63 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 65 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 66 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 67 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I.(as per UPPWD approved make list) 68 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 69 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 70 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 74 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 75 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect.(as per UPPWD approved make list) 76 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 77 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate(as per UPPWD approved make list) 78 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate (as per UPPWD approved make list) 79 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 80 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 81 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia(as per UPPWD approved make list) 82 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 83 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates as per previous sanctioned(as per UPPWD approved make list) 84 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Havells, Polycab, Grandlay, Gloster, KEI make) 85 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 86 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. (as per UPPWD approved make list) 87 Lettering with black japan paint of approved brand and manufacturer(as per UPPWD approved make list) 88 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 89 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 90 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 91 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 93 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 96 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 97 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 300 sq.mm 3 core 11 KV HT XLPE Cable (Havells, Polycab, Grandlay, Gloster, KEI make) 98 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc.. 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list)(Havells, Polycab, Grandlay, Gloster, KEI make) 99 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 103 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size. rate as per sanctioned vide Job no. ED-I (83) Dt. 25.11.2021(as per UPPWD approved make list) 104 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. Rates as per sanctioned vide job no.ED-1 (83) Dt. 25.11.2021(as per UPPWD approved make list) 105 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 106 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल )(as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 110 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 111 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 112 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 113 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 114 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 115 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I.(as per UPPWD approved make list) 116 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I.(as per UPPWD approved make list) 117 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I.(as per UPPWD approved make list) 118 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 119 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I.(as per UPPWD approved make list) 120 Supply & Installation of Top Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 121 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 122 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I.(as per UPPWD approved make list) 123 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 124 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I.(as per UPPWD approved make list) 125 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 126 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 127 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.. Main LT Panel #1 INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 128 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 129 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 130 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Havewlls, Polycab, Grandlay, Gloster, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(Havewlls, Polycab, Grandlay, Gloster, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Havells, Polycab, Grandlay, Gloster, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Havells, Polycab, Grandlay, Gloster, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 136 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 137 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 138 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core (Havells, Polycab, Grandlay, Gloster, KEI make) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 145 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 146 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 155 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 156 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 157 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 158 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed atsite by Engineer in charge.(as per UPPWD approved make list) 159 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 160 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 161 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 163 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 164 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 165 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable)(as per UPPWD approved make list) 166 Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P.(as per UPPWD approved make list) 167 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 170 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work.(as per UPPWD approved make list) 171 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 172 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 173 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 174 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
36.
Public Administrative Department #9470838 Technical Bid
Beautification and improvement work of Adonis Nimbu Park situated at Nazul - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 3 Synthetic Acrylic Surface , 8 Layer cushion System 4 Supplying and Fixing of Frog Bin - FRP outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPDB11, Make Fun Play/ Kompain/ Arihant) PSR 5 Supplying and Fixing of Imperial Bench 4 outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPGD11, Make Fun Play/ Kompain/ Arihant) PSR 6 Supplying and Fixing of Turbo Tower outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPCL35 , Make Fun Play/ Kompain/ Arihant) PSR 7 structural steel work riveted, bolted or welded in built up sections, trussses and framed work including cutting, including cutting, hoisting, fixing in position and applying a priming coat of approve steel primer all complete DSR 10.2 8 Providing and fixing bolts including nuts and washers complete.DSR 10.20 9 Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works DSR 13.50.2 10 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work DSR13.52.1 11 Aqua soft RO Plant250 LPH 12 Surise water cooler 200 LTR FSS 13 Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.DSR 2023 / 18.48A 14 Excavation in foundation in ordinary soil (loam clay or sand) including lift up to 1.5 m and lead up to 30m. And including filling watering and ramming of excavated earth into the space between the building and the sides removal and disposal of surplus earth as directed by the engineer in charge up to a distance of 30m from the doundation trenches including all T&P phowarah and basket etc. complete. 15 Cement Concrete with 40 mm gauge approvedStone ballast ,Coarse sand and cement in proportions of 8:4:1 including supply of all materials, labours,tools & plants etc. required for poper completion of the work, Excluding GST 16 Same as item no Above For lintel in 1:1.5:3 (1 cement : 1.5 Coarse sand :3 Graded stone aggregate 20 mm nominal size (Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks) 17 Same as item no Above For lighter beams in 1:1.5:3(1 cement : 1.5 Coarse sand :3 Graded stone aggregate 20 mm nominal size 18 Same as item no Above For slabs in 1:1.5:3(1 cement : 1.5 Coarse sand :3Graded stone aggregate 20 mm nominal size 19 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers 20 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform 21 Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the workand including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. 22 Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete 23 P/F MS grills of required pattern in frames of windows fixed to opening/wooden frames with rawl plugs screws etc. 24 Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 25 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation .50 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 26 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation .50 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 27 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 28 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 29 Providing and fixing panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Second class teak wood - 35 mm thick shutters. 30 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class Teak wood 31 Providing & fixing glass panes with putty and glazing clips in steel / Wooden doors, windows, clerestory windows, all complete with : 5 mm thick glass panes 32 Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :125x65x2.12 mm 33 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete 200x10 mm 34 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete 200x10 mm 35 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 36 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 37 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 38 Add for plaster drip course/groove in plaster the all or in ceiling vertically or horizontally as required. 39 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 40 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab over 0.50 sqm 41 Finishing walls with Premium Acrylic Smooth exterior paint with Siliconeadditives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 42 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 43 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work 44 Painting or varnishing on iron works in small areas or new wood work with one coat of ready mixed priming paint & two coats of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and t & p etc. required for proper completion of work. paint to be used should confirm to the IsI no. 103 1950. 45 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand)admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surfacewith trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm 46 8.2, Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 8.20.1, Red sand stone - 30mm thick gang saw cut stone 47 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).DSR Horticulture 2020; 2.25 48 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 49 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). DSR Horticulture 2020; 2.8 50 Hedge Plant 2.57.3 (Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) DSR Horticulture 2020; 2.57) 51 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020; 6.7 52 Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge. DSR Horticulture 2020; 5.3 53 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy infull bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge.,DSR Horticulture 2020; 5.12 54 Providing and Displaying Cycus revoluta specimen , having 45 to 50 freshand healthy, leaves having 30cm to 35cm circumfrance of base stem welldeveloped in 40 cm challi, as per direction of the officer-in-charge.DSR Horticulture 2020;5.15 55 Providing and stacking of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge.DSR Horticulture 2020; 6.25 56 Providing and Displaying Cyprus Golden Conical Shape 150 to 165 cmht., with fresh and healthy Golden colour foliage in 35cm Cement Pot asper direction of the officer-in-charge.DSR Horticulture 2020; 5.18 57 Providing and Displaying Ficus Retusa topiary well developed with fresh &healthy 5 to 6 big ball specific size and shape 180 to 210cm ht in 40 cmCement Pot as per direction of the officer-in-charge. DSR Horticulture 2020; 5.24 58 Providing and Displaying Foxtail palm well developed with fresh & healthyfoliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of theofficer-in-charge.DSR Horticulture 2020, 5.30 59 Providing and Displaying Furcaria Variegated hybrid well developed withfresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Potas per direction of the officer-in-charge. DSR Horticulture 20205.32 60 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-charge.DSR Horticulture 2020 8.14 61 Providing and stacking of Murraya exotica of height 45-60 cm. in poly bagsof size 15 cm as per direction of the officer-in-charge.DSR Horticulture 2020, 8.46 62 Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of theofficer-in-charge.DSR Horticulture 2020, 8.48 63 Providing and stacking of Plumbego capensis well developed with freshand healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Potas per direction of the officer-in-charge..DSR Horticulture 2020, 8.55 64 Providing and stacking of Tabernaemontana coronaria (chandni variegated) of height 45-60 cm. with 3-4 branches earthen pots of size 20 cm as per direction of the officer-in-charge.DSR Horticulture 2020, 8.61 65 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm.in big poly bags of size 25 cm as per direction of the officer-in-charge.DSR Horticulture 2020, 7.16 66 Providing and stacking of Allamanda cathartica of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 9.1 67 , Providing and stacking of Bignonia venusta (Golden shower) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.9.3 68 Providing and stacking of Ipomoea purpurea (Morning glory) of height30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge., 9.7 69 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge., 9.12 70 Providing and stacking of Vernonia elaegnifolia (curtain creeper) plant of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge., 9.14 71 Providing and stacking of Petra volubilis of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge., 9.11 72 Trenching and Back Filling. Sanctioned Rate. 73 Supplying Testing & Installation of Garden Spike Light 12W WWMake Philips/ Wipro/ Lusteretc all complete of direction of engineer in charge. 74 Supply and fixing of decorative16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. Alluminium make approx 2 feet height 75 Supply, Installation, Testing and Commissioning of LED RGB/RGBWfloodlighting luminaire for facade lighting with Die-cast aluminiumhousing, powder-coated finish, of following wattage. Luminaireshall be capable of producing dynamic color changing light for with16 million colors by DMX/Ethernet based control. The beam angleof the fitting shall be narrow, medium, wide or asymmetric as perthe requirement. Luminaire shall be complete with driver andcapable of operating at line voltage without any separate powersupply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixtureshall be suitable to operate at an ambient temperature range of -10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be atleast L70:50000 burning hours at 50°C. Luminaire shall beconforming to BIS (IS 10322) and shall be complete with allnecessary accessories required for proper working of fixtureincluding weather proof connection cables, water proof connectorsetc. as required. 250 W 1.3 76 6.00 Sqmm 4 Core (Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ) 77 25.00 Sqmm 3.5 Core (Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ) 78 70.00 Sqmm 3.5 Core (Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ) 79 63 mm dia (OD-63 mm & ID-51 mm nominal) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 80 90 mm dia (OD-90 mm & ID-76 mm nominal) Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 81 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 82 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 83 50 mm dia. (Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince)) 84 P-Trap type Floor Trap 110 x 75 mm(Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince)) 85 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 86 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 87 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. 88 Same as in item no. 1 but for fan. and light duty exhaust fan 89 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. 90 Add for light / fan points with modular type switches in place of piano type switches 91 Add for plug point with modular switch & socket in place of piano type switch & socket 92 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work 93 2 x 4 sq. mm.In 20 mm dia conduit. Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 94 2 x 10 sq. mm.In 25 mm dia conduit. Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 95 12 WAYS CAT-B (S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge.) 96 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) 97 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) 98 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B 99 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . 100 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. 101 10 sqmm 2core (Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.) 102 10 sq.mm. Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 103 10 sqmm 2core (Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor.) 104 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. 105 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. 106 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. 107 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA 108 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. 109 300 mm sweep 110 300 mm sweep 900 rpm ((Make : Bajaj / Crompton / Havells) Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete )
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
37.
Public Administrative Department #9466543 Technical Bid
Tender For Work Of Setting Up A Gazebo In Front Of The Canteen Located In Dr. Ram Manohar Lohia Park Under Gomti Nagar Scheme - Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and belowDSR 15.12.1 2 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completeDSR 13.88 3 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortarDSR 15.7.4 4 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mmDSR 15.23.1 5 Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge. 6 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi chambered frame, sash and mullion/coupler (where ever required)extruded profiles having minimum wall thickness of .70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 To 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash 7 mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rof of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge.Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed>45 m/sec as per IS 875-Part 3 (ii) Sites with structure height more than 20m for all wind speeds9.147.A4. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Heigh above 1.8 m)DSR 9.147.A4.2 7 Toughened glass 12 mm thicknessDSR 8778 8 Stainless steel wire guage (Grade-304) aperture 1.4 mm and0.50mm dia wireDSR 8737 9 Weather Silicon sealantDSR 8646 10 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). 11 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 13 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 14 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 15 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primerDSR 13.41.1 16 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 17 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 18 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mm 19 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. 20 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured. 21 LDA approved steel 22 Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fastlugs or with dash fasteners of required dia & length (hold fast lugs ordash fastener shall be paid for separately). Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the doorframe to be Jointed with galvanized brackets and stainless steel screws,joints mitred and Plastic welded. The hinge side vertical of the framesreinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the framecomplete as per manufacturer’s specification and direction of Engineerin-charge 9.117.1 Extruded section profile size 48x40 mm 23 9.118 Providing and fixing to existing door frames.9.118.1 24 mm thick factory made PVC door shutters made of stylesand rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by meansof M.S. galvanised/ plastic brackets of size 75x220 mm havingwall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollow section of size100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. U cleats.The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thicknessof 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturers specification anddirection of Engineer-in-charge. (For W.C. and bathroom doorshutter). 24 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil DSR 2023, 2.6 25 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.8 26 Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 8.2.2 Granite stone slab of colour black, Cherry/Ruby red8.2.2.1 Area of slab upto 0.50 sqm 27 8.2.2.2 Area of slab over 0.50 sqm 28 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand): 25mm thick External Area Repair 29 Providing & fixing of Dustbin made in mild steel frame with painting & polish and frame wooden member fixed in m.s. frame including painting polishing as per drawing & design all complete in direction of engineer in charge. 30 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications includingc c 1 :2 :4 grouting, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge 31 Supplying and stacking of good earth at site including royalty and carriage upto 20 km lead complete (earth measured in stacks will be reduced by 20% for payment). (1x2x13.50x18.50) 32 Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bagsof size 25 cm as per direction of the officer-in-charge.DSR 2020 Horti./8.32 33 Providing and stacking of Tabernaemontana coronaria (chandni variegated) of height 45-60cm. with 3-4 branches earthen pots of size 20 cm as per direction of the officer-in-charge.DSR 2020 Horti./8.61 34 Providing and stacking of Tabernaemontana coronaria (chandni variegated) of height 45-60cm. with 3-4 branches earthen pots of size 20 cm as per direction of the officer-in-charge.DSR 2020 Horti./8.61 35 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen pots of size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-charge.DSR 2020 Horti./8.14 36 Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branchedin earthen pots of size 25 cm as per direction of the officer-in-charge.DSR 2020 Horti./8.48 37 Providing and stacking of snow bush of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.Quatation rate 38 Providing and stacking of mokatia of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.Quatation rate 39 Providing and stacking of Ixoraof height 75-90 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.Quatation rate 40 Trenching and Back Filling. Sanctioned Rate. 41 Supply and fixing of 3500mm decorative ribbed steel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8 & with having for twin nos bracket. The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 42 Supply and fixing of 534 mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore or equivalent repuateted make Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 43 Supply and fixing of decorative16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. Alluminium make approx 2 feet height 44 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 45 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 46 Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 47 6.00 Sqmm 4 Core (Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ) 48 25.00 Sqmm 3.5 Core (Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ) 49 70.00 Sqmm 3.5 Core (Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ) 50 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN 51 63 mm dia (OD-63 mm & ID-51 mm nominal) (Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required) 52 90 mm dia (OD-90 mm & ID-76 mm nominal) (Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required) 53 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 2.6.1 54 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8, 4.1.8 55 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but Excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All Work Above Plinth Level DSR 5.37.2.1 56 Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. Thermo-Mechanically Treated bars. 57 Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. completeDSR 11.35 58 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR 10.1 59 Providing wood work in frames of / Railing / false ceiling, partitionsetc. sawn and fixed in position with necessary stainless steel screws etc. Sal wood9.3.1 60 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR5.9.1 61 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 13.4.2 62 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with :Second class teak woodDSR 11.33.1 63 French spirit polishing :Two or more coats on new works including a coat of wood filler DSR 13.68.1 64 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. 65 Same as in item no. 1 but for fan. and light duty exhaust fan 66 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. 67 Add for light / fan points with modular type switches in place of piano type switches 68 Add for plug point with modular switch & socket in place of piano type switch & socket 69 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work 70 2 x 4 sq. mm.In 20 mm dia conduit. (Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects.) 71 2 x 10 sq. mm.In 25 mm dia conduit. (Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects.) 72 12 WAYS CAT-B (S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge.) 73 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) 74 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) 75 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B 76 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . 77 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. 78 10 sqmm 2core (Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.) 79 10 sq.mm. (Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge.) 80 10 sqmm 2core (Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor.) 81 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. 82 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. 83 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. 84 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA 85 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. 86 300 mm sweep (Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete ) ((Make : Bajaj / Usha / newtek / Havells)) 87 300 mm sweep 900 rpm (Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete ) ((Make : Bajaj / Crompton / Havells)) 88 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 89 Providing and fixing the taps attached to the shower divertor and the the sink 90 Providing and fixing the shower heads 91 Providing and fixing the shower diverters 92 32 mm dia (for wash basin) Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 93 40mm nominal outer dia pipes (Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.) 94 50mm nominal outer dia pipes (Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge.) 95 15mm nominal outer dia pipes (Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc.) 96 20mm nominal outer dia pipes (Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc.) 97 25mm nominal outer dia pipes (Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc.) 98 32mm nominal outer dia pipes (Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chase and making good the wall etc.) 99 40 mm nominal bore (Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end)) 100 50 mm nominal bore (Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end)) 101 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. 102 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 103 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. 104 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 105 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. 106 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 107 150 x 100 mm. size P type (Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design) 108 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 109 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 110 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 111 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) (Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince)) 112 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 113 50 mm dia. (Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince)) 114 P-Trap type Floor Trap 110 x 75 mm(Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince)) 115 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 116 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Uttar Pradesh View Result →
38.
Public Administrative Department #9463829 Technical Bid
Tender for the remaining work (development work and electrification work) of Sanskriti School under construction under CG City Scheme, 1 ROAD WORK 2 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. DSR 16.1 3 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD SOR 4 Providing and laying design mix cement concrete of M-30 grade, inroads/ taxi tracks/ runways, using cement content as per designmix, using coarse sand and graded stone aggregate of 40 mm nominalsize in appropriate proportions as per approved & specified designcriteria, providing dowel bars with sleeve/ tie bars wherever required,laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdyM.S. channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints ( 10 mm wide x 50 mmdeep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction ofEngineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement content in M-30 is @ 340 Kg/Cum. Excess/Less cement Used as per design mix is separately.DSR 16.43.2 5 Providing and fixing in position pre-moulded joint filler in expansion joints.DSR 16.45 6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD SOR 504 7 PARKING 8 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 9 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD 10 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturers specifications & direction of Engineerin-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. DSR 16.91.2 11 Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. DSR 16.63 12 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment. (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69 13 DRAIN 14 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.DSR 2.8.1 15 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)DSR 4.1.8 16 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level DSR 5.33.1 17 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD 504 18 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) DSR 13.7.1 19 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2 20 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1 21 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.DSR 23.9 22 COLUMN UPTO 10 FT 23 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6. 24 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work,including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level DSR 5.37.1 25 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 26 RETAINING WALL 27 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 28 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 29 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 30 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 31 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size). DSR4.1.6 32 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 33 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR 5.9.2 34 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 35 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 36 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 37 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm DSR 22.23.2 39 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. DSR 22.1.1 40 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone DSR 22.2.1 41 SKYLIGHT & BRICK WORKS 42 Providing & fixing of roof with multilayer standing seam polycarbonate panel system of 18mm thickness (min) including all standard fixing accessories on top of the supporting structure (paid extra) complete & as per the direction of the engineer in charge. The panels should work on angular daylighting concept with translucent and opaque combination of louvers inside, for better thermal insulations and diffusion of light especially with white and clear combination designed for tropical regions & shading throughout the day for better ambient temperature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The entire panel system shall be with a width from min 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on purlin with snap on connectors with grip lock double tooth locking mechanism and will be secured on MS Structure/ purlins (will be paid separately) with HDSS Fastener and double tooth polycarbonate connector for best stability and having a pull-out load of min 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels cell structure be in truss bridge design or commonly called X structure for better strength and stability. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on polycarbonate panel which have been exposed to UV for a min. of 500 hours as per ASTM G155. Panels shall not have yellowness Index as per ATSMD 1925 of 15 units when tested on a sample exposed to UV for 500 hours as per ASTM G 155. U value shall not be more than 2.0W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cp/ Aluminium U/F profile/ Glazing Bar (all mill finish) for ends as required. Trained and factory authorized layout with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge.Colour: as per approval. 43 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 44 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 45 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 46 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) DSR 13.5.2 47 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 48 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) DSR 13.46.1 49 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 50 CHAIN LINK FENCING 51 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 52 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 53 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 54 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 55 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR 4.1 56 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 57 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 58 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 59 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 60 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade DSR 16.70.2 61 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes DSR 10.16 62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 63 M.S. GRILL WORKS 64 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding DSR 9.48.1 65 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece DSR 10.5.2 66 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 67 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 68 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 69 BASEMENT WORK 70 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 71 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 72 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 73 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). DSR 4.1.10 74 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1 75 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 76 BASKETBALL COURT 77 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 78 Synthetic Specification: -Providing and laying of ITF Classified material. 8 layers System Synthetic Acrylic for Synthetic Basketball Court:-(1 layer) Conrete Primer(2 layer) Resurfacer(3 layer) Cushion Rubber(4 layer) Top CoatWhite Line Marking as per standard 79 Basketball pole fix type 6” round pipe , Projection 2*20 Acrylic board 20mm Malaysia with dunking ring (3 spring) 80 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P. 81 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 82 SPORTS FACILITIES 83 LAWN TENNIS COURT 84 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 85 Synthetic Specification: -Providing and laying of ITF Classified imported material (AcryCoat Made In Europe)8 layers System Synthetic Acrylic for Synthetic Court :-• (1 Layer) Concrete Primer • (2 layers) Acrylic Resurfacer• (3 layers) Cushion • (2 layers) Top Coat•Line Marking 86 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P 87 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 88 Pole socket type 80*80 mm , thickness (4 mm) with net 89 SKATING RING 90 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 91 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverableseparately). DSR 16.75 92 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksDSR 10.25.2 93 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete.New work (Two or more coats) DSR 16.47.1 94 HORTRICULTURE AND LANSCAPING 95 Supply and stacking of of good earth at site including royaltyand carriage up to 1 Km DSR 2.2 96 Supply and stacking of sludge at site including royalty and carriage up to 1 Km DSR 2.3 97 Supply and stacking of dump manure from approved source at site including carriage up to 1 Km DSR 2.4.3 98 Rough dressing the trenched ground including breaking of clods DSR 2.5 99 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.6 100 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.7 101 Spreading of sludge, dump manure and or good earth and mixing as per direction of engineer incharge DSR 2.8+2.9 102 Grassing with selection No-1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn. free from weeds and fit for moving and disposal of rubbish as directed DSR 2.10.1 103 Half brick circular treeguard in brick 1.25 m internal dia and of ht 1.20 m above ground and 0.20 m below ground..... DSR 2.15 104 Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. DSR 2.54 105 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. DSR 2.56 106 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge DSR 7.5 107 Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge DSR 7.24 108 Supply and stacking of Ficus bengalensis (Bargad) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR 7.28 109 Supply and stacking of Ficus elastica Decora (Rubber plant) plant of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.DSR 7.31 110 Supply and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-incharge DSR 7.63 111 Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. DSR 7.75 112 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge DSR 2.28 113 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge DSR 2.33 114 Plumbing Detail 115 SANITARY FIXTURES 116 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1 117 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DSR 17.78 118 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.. DSR 17.80 119 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 120 Providing and fixing toilet paper holder : C.P. brass DSR 17.34.1 121 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single holebasinmixer. 122 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm. DSR 17.10.1.1 123 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore DSR 18.53.1 124 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore DSR 18.51.1 125 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore DSR 18.16.1 126 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 127 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. MR 128 Providing and fixing of SS coat hook complete in all respect as approved by Engineer In Charge MR 129 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.DSR 17.70.1 130 Providing and fixing of SS grab bar complete in all respect as approved by Engineer In Charge MR 131 Providing and fixing urinal partition chinaware complete in all respect MR 132 Providing and fixing of sink mixer complete in all respect. MR 133 Providing and fixing SS labourtory sink as per detailMR 134 Providing and fixing laboratory sink mixer complete in all respect.MR 135 Providing and fixing drinking water sink complete in all respects MR 136 SOIL , WASTE AND VENT SYSTEM 137 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings: 75 mm dia 138 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 100 mm dia 139 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 150 mm dia 140 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless : 100 mm inlet and 100 mm outlet DSR 17.60.1 141 Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. DSR 18.58.1.1 142 Providing and fixing floor clean out plug consist of CI bend & GI socket heavy class with Brass cap & key for opening male threaded cap etc. including lead caulked to CI pipescomplete in all respects as per drawing / sample approved by Engineer -in -ChargeFCO (floor clean out plug shall be flushed with floor finish: 100 mm dia/150 mm dia 143 Water Supply system 144 Inside Toilets 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work. DSR 18.9 146 15 mm nominal outer dia. Pipes. 147 20 mm nominal outer dia. Pipes. 148 25 mm nominal outer dia. Pipes. 149 Distribution lines 150 Providing and fixing of GI Pipes medium class IS :1239 including all required fittings etc. DSR 18.12 151 20 mm dia. nominal bore 152 25 mm dia. nominal bore 153 32 mm dia. nominal bore 154 40 mm dia. nominal bore 155 50 mm dia. nominal bore 156 65 mm dia. nominal bore 157 80 mm dia. nominal bore 158 100 mm dia. nominal bore 159 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore DSR 18.13.1 160 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore DSR 18.13.2 161 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). DSR 18.14 162 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore: DSR 18.17 163 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. DSR 18.17.2 164 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore DSR 18.17.3 165 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore DSR 18.17.4 166 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore DSR 18.17.5 167 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore DSR 18.17.6 168 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore DSR 18.18.1 169 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore DSR 18.18.2 170 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore DSR 18.18.3 171 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 172 Providing and fixing submrsible vertical drainage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand bysolid hanldling 40 mm size.discharge 5 lps and head-15 mtr 173 Providing and fixing submrsible vertical sewage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand by solid hanldling 40 mm size.discharge 5 lps and head-15 mtr 174 RAIN WATER SYSTEM 175 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 100 mm dia 176 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 150 mm dia 177 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 200 mm dia 178 Making of 600x600 mm size khurah complete in all respects including water proofing etc. 179 EXTERNAL SEWARAGE AND DRAINAGE 180 GARDEN IRRIGATION 181 Providing and fixing HDPE pipes conforming to IS:4984 PE 63 Class IV (6 kg/sqcm) including all fittings, e.g.couplings, tees, bends, reducers and screwed adoptors, welded joint as per manufacturers recommendations. 182 a) 32 mm O.D. 183 b) 40 mm O.D. 184 c) 63 mm O.D. 185 Providing and fixing uPVC Schedule 40 pipes conforming to ASTM D-1785complete with uPVC Schedule 40 fittings including necessary cutting of pipes, jointing with HDPE pipe with sadddle fitting completewith testing and commissioning of pipe lines : (a) 1 nominal size 186 Providing and fixing 25 mm brass dia quick coupling valve fitting with auto-close lid, SS spring, brass valve, complete in all respects (Harit model HT-71Bor eq.). 187 Providning and fixing bronze ball valve with screwed female/flangedends with stainless steel valve and spindle, glass fileed tefelon seating and gland packing, quarter turn lever operate full bore design, hydraulically tetsed to 20 kg/sqcm 188 a) 25 mm nominal bore 189 b) 40 mm nominal bore 190 a) 50 mm nominal bore 191 Providing and fixing cast iron flanged wafer type butterfly Valve with quarter turn operation complete in all respects confirming to IS:13095 PN1.0: (a) 65 mm dia 192 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. cover 500x450 mm R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 193 Providing and fixing 15 mm N.B. air release valve alongwith FTA I/c 1 no. ball valve for fixing to HDPE pipeline complete 194 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 195 SEWERAGE 196 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 197 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (b)Extra over 1 (a) above for excavation over 1.5 m depth . 198 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (a) 200 mm OD 199 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 250 mm OD 200 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (c) 300 mm OD 201 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. :(a) 200 mm OD 202 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. (b) 250 mm OD 203 Providing and fixing square mouth S.W. gully trap grade A complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water & gas tight SFRC Cover with frame of 260x260 mm size clear opening, frame of size 390x390 mm with weight of frame to be not less than 10 Kg and cover of size 300x300 mm with weightof cover not to be not less than 9 Kg as per standard design: (a) 180X 150 mm size P type with F.P.S. bricks of class designation 75 204 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 205 Extra for depth beyond 45 cm of brick masonary chamber : for 455X610 mm size : With F.P.S. bricks 206 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand)inside cement plaster 12mm thick with cement mortar1:3 ( 1 cement :3 coarse sand ) finished with floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement 3 Coarse sand: 6graded stone aggregate 40mm nominal size) and making necessary channelin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) finished witha floating coat of neat cement all complete as per standard design: 0.91 m deep with SFRC cover and frame ( Heavy duty HD-20 gradedesignation) 560mm internal diameter conforming to IS:12592 total weightof cover and frame to be not less than 182 kg, fixed in cement concrete1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (excavation, foot rests and 12 mm thick cement plaster at the surface shall be paid seperately): with F.P.S. bricks class desigantion 75 207 Extra depth for circular type manhole 0.91 m internal dia (at bottom) with beyond 0.91 m to 1.67 m, withF.P.S. bricks class designation 75 208 DRAINAGE SYSTEM 209 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 210 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (b) Pipes, cables etc. exceeding 300 mm dia. 211 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(a) 200 mm OD 212 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 250 mm OD 213 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 300 mm OD 214 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (a) 200 mm OD 215 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (b) 250 mm OD 216 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (a) Inside size 90X80 cms and 60 cms deep including SFRC cover with frame (heavy duty) 500 mm dia clear opening 217 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (b) Inside size 120X90 cms and 90 cms deep including SFRC cover with frame (Extra heavy duty) 560 mm dia clear opening. 218 Extra for additional depth of manholes: (a) Size 90X80 cms beyond 60 cms depth 219 Extra for additional depth of manholes: (b) Size 120X90 cms beyond 90 cms depth 220 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 221 Constructing brick masonary road gully chamber 50X45X60 cm with bricksof class designation 75 in cement mortar 1:5 (1 cement: 5 fine sand) including 500X450 mm precast RCC horizontal grating with frame complete as per standard design:With F.P.S. bricks 222 Making connection of stormwater lines with existing municipal manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: (a) For pipes 250 to 450 mm diameter 223 FIRE FIGHTING WORKS 224 FIRE FIGHTING 225 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(a) 80 mm dia ( 4.85mm thickness) 226 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(b) 100 mm dia ( 5.40mm thickness) 227 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(c) 150 mm dia ( 5.40mm thickness) 228 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(a) 100 mm dia 229 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(b) 150 mm dia 230 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(a) 100 mm dia 231 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(b) 150 mm dia 232 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:( a) 65 mm dia 233 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:(b) 150 mm dia 234 Supply, Installation, Testing and Commisioning ofC.I.`Y strainer with bronzeperforatedsheetbasket includingrubber gasket, flanges, nuts, bolts and washers, complete as required.: (a) 150 mm dia 235 Supply, Installation, Testing and Commisioning of SS single head fire hydrant valvewith80 mm N.B.flangedinlet, brass spindal, one no. 63 mm dia femaleinstantaneousoutlet type. G.M. coupling,blank cap, chain. Conforming to IS:5290.Includingtappingfromwet riser complete as required. 236 Supply, Installation, Testing and Commisioning ofHose pipe, 63 mm diaand15mts long, duly reinforced, rubberlined suitable forbrusting pressurenot lessthan22Kg/Sqcm. conformingtoIS 636-1988type A with gun metal heavy dutyinstantaneous type coupling ( Pairmale&femaleparts) conforming to IS 903. Complete as required. 237 Supply, Installation, Testing and Commissioning of63 mm dia instantaneouspattern branchshort SSpipe,16 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required. 238 Supply, Installation, Commisioning of standard firemans axe with heavy rubber handle. 239 Supply, Installation, Testing and Commissioning ofinletbreaching havingC.I.bodyfourway SS 63 mm diainstantaneousinlets conforming toIS 903fittedwithnon returnvalves, 25 mm diagun metal drain cock, blank cap, brasschains and 150 mm dia flanges with allaccessories suitableforlocal fire tender complete as required. 240 Supply, Installation, Testing and Commissioning ofSS Fire Brigadeadopter assemblywith150mm diaoutlet,suitableforlocalfire tender complete as required. 241 Supply, Installation, Testing and Commissioning of weather proof cabinet of size not less than0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.)suitably markedon the outside with the letters FIRE HOSE including necessary lockingarrangement and painting in red coloursuitableto accomodate, externalyard hydrant valve, 2 nos15 mtrlongHose pipe, branch pipe, nozzle and fire mans axe. It shall be mounted on boundary wall complete as required. 242 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.: Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.: M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 70 m Head 243 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump): Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.: 2280 lpm at 70 m Head 244 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) : Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.: Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.: M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.: Suitable cement concrete foundation duly plastered and with anti vibration pads. : 180 lpm at 70 m Head 245 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 246 INCOMING:250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc:LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING:( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 247 Jockey Pump : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL 248 Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 249 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe 250 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 251 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 252 FINISHING WORK 253 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) DSR 21.1.1.2 254 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)DSR 21.1.2.2 255 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides DSR 21.2.2 256 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness: DSR 21.3.2 257 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm: DSR 9.95.1 258 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm: DSR 9.96.1 259 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm: DSR 9.97.1 260 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm: DSR 9.100.1 261 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: Twin rubber stopper: DSR 9.101.2 262 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturers specification.: Two or more coats on new work: DSR 13.42.1 263 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall conform to ASTM 6063). : Floor Joint of 100 mm gap: DSR 5.44.1 264 Providing and fixing of expansion joint system related with wall joint (internal / external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.): Wall Joint of 100 mm gap:DSR 5.45.1 265 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) : Roof Joint of 100 mm gap : DSR 5.46.1 266 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 267 CONNECTING BRIDGE 268 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer allcomplete. DSR 10.2 269 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 270 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62 271 ROOF SKYLIGHT -18 mm THK POLYCARBONATE SHEET Supply and Installation of polycarbonate multi-layered, Multicell Xfix Connectible modular panel system for, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Standing seam polycarbonate panel system of minimum 18 mm thick (Min.) Panels with bigger width will be preferred for reducing number of joints in the roof.Panels shall be with grip lock double tooth lockingmechanism with interlocking connectible connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS tructure (will be paid Separately) with self-drilling screws and specialsTrapezoidal Heavy Duty Fastener/ Al- Cleat to ensure a pull-out load of min. 7000N (7KN) testedas per ISO 6892:1998 and IS 1608: 2005. The min width of the panel system shall be 900mm (min.). 272 Panels shall be uniform in color UV protected in combination with seven layers for required lux level, along with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels with morelayers will be preferred for better insulation and improved shading coefficient. Prices includes All accessories including Aluminum profiles with EPDM Gaskets, at alternate edges with taper cutting to achieve the required profile, aesthetics and performance criteria. U value shall not be more than 1.8 Watt/m2K as per EN ISO 1077- 2:2018 and respective third Party test certificate shall be produced before procurement. 273 Panels shall have an X cell structure also called truss bracing design to have more strength and flexibility simultaneously. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155.Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factoryauthorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. 274 LEVELLING 275 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. SOR 2.31 276 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.32 277 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.33 278 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.: Beyond 60 cm girth upto and including 120 cm girth: SOR 2.33.2 279 EXTERNALELECTRICAL 280 COMPACT SUB STATIONS - 01 (with OLTC) 281 Supply, Installation, testing and Commissioning of 11 kV / 0.415 KV Compact Sub Station(with OLTC)outdoor plinth mounted type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated VCB compact switchgear (RMU) having metal enclosed robotically sealed/welded stainless steel tank , L T Panel, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type, otherassociated equipment etc. complete as required conforming to detailed specification. 282 The enclosure shall have modular construction usingG.I. sheets and shall be painted with polyurethane paint from the exterior of approved shade. The enclosure for LT switchgear & HT switchgear shall be provided with IP54ingress protection. The transformer compartment will have IP23 ingress protection. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment.Transformer compartment door shall be interlocked with HT breaker.The transformer used shall be specially designed for low losses and shall be hermetically sealed & with corrugated tank. 283 The L T ACB shall have inbuiltmicroprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases with Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 284 L T Panel BUS : 415 Volts, 3 phase 50 HZTPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. 285 The Transformer losses should confirm to IS - 1180 Part-1 (2014) efficiency Level - 2[ 1.86 KW at 50% load & 5.3 KW at 100% load shall not exceeds by 5.0% of the maximum total loss values. 286 The combination of CSS shall be as per details below:- 287 (a) Supply of 3 way 11kV ,3Phase, 50Hz, 3 wire , earthed neutral, Indoor type floor mounted, non extensible, having hinged arc proof cable doors, breaking capacity 18.4 kA,VCB Ring Main Unit enclosed in robotically laser welded stainless steel tank having IP67 degree of protection consisting of following:- 288 (i) 1 Nos. 630Amps Fault making load breaking spring assisted SF6 Ring Switches, fitted with fixed type voltage indicator device as per IEC 61958 along with associated sensor and fault passage indicator.(ii) 2 No. 630Amps tee off spring assisted type vacuum circuit breaker unit with self powered series trip microprocessor based numericalover current and Earth faultrelay for protection, fitted with fixed type voltage indicator device as per IEC 61958, along with associated sensor and fault passage indicator and ring core type protection Current transformer along with LV compartment with Ammeter with selector switches.(iii)Air Insulated Metering panel connected along with above unit , 18.4 kA , 630 amps, having Potential transformer,connected jumpers / Bus Bar, LV Compartment to incorporate Votmeter andEnergy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI as per the requirement (at incoming VCB) (Please refer SLD). 289 (b)1 No. 11 KV/415 V, 630 KVA three phase (with %Z is 4.5%) , 50 HZ, DYn11, +10% to -10%in 2.5% equal steps ON LOADTAP CHANGER (OLTC), oil cooled, outdoor mounting type, hermitically sealed, corrugated wall design low loss transformer with Cu winding and standard fittings.(minimum 240 Sq MM HT (E) XLPE AL cable are used for the connectivity between transformer &HT Breaker) 290 LT Bus Bars : 1000 AMP,500 Volts, 3 phase 50 HZTPN. The current density of bus bar shall not exceed1.0 sqmm / Amp 291 Neutral Bus : - Separate 2 nos 32 x 6 mm Copper insulated strip (with conductivity mim 99%) directly connected from neutral point of transformer. 292 (c )Incoming cum Outgoing - 415 VoltL.T. breaker Panel having 1000 Amp FP ACB, 50 kA fixed type, with microprocessor based O/L, E/F, S/C, Inst. S/C releases with CT/PT, ammeter with ASS, Voltmeter with VSS, PF meter, Hz meter, energy enalyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI,phase indicating lamps, On/Offf/Trip indication. 630 KVA Compact Sub Station. 293 DIESEL GENERATING SET 294 Supply, Installation, testing and Commissioning ofSilent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization / PLC based load manager, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. 295 Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. 296 Instrument Panel - Engine mounted Instrument Panel fitted withand having digital display for followings : 297 Start stop switch with keyWater temperature indicationLubrication oil pressure indication.Lubrication oil temperature indication.Battery charging indicationRPM indicationOver speed indicationLow Lube oil trip indicationEngine hours indication 298 Alternator- Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required. 299 Note : - Alternator should have with all other accessories as per specified in Technical specfications. 300 Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.Inbuilt Fuel tank ofstandard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.Daily service Fuel tank of990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system,level indicators and all standard accessories etc. as required.Exhaust Silencer - Exhaust manifold with residential silencer.The D G set should be supplied with required hardware for external PLC based auto load management system.Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. 301 550 KVA 302 Supply, Fixing, testing and Commissioning of Exhaust gas piping system ofClass `B MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil.The measurement shall be doneon the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will gowell above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will beconfirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval): 300 mm dia (wall thickness - 4.85 mm) (for 625 KVA DG sets) 303 Supply & fixing of SSBellow of following diameter : 300 mm dia(for 500 KVA DG sets) 304 Supply & fabrication ofD G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MSangle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation. 305 FUEL PIPING 306 Providing and fixing in position the following MSpipes classC (As per IS : 1239) cut to required lenghts and installed with screwed joints including providing and fixing in position the necessary fittings like elbows, tees and reducers, sockets, MS supports and accessories including digging and refilling earth where required for buried pipes / suspended from ceiling including pipe hanger / clamped from wall including hardware complete as per site requirement.: 25 mm NB MS pipes (IS: 1239, 4.0 mm thick) 307 Providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with PVC grip, teflon seat, screwed ends tested to a pressure of 10 kg/sqcm suitable for HSD complete.:25 mm nominal bore 308 Supply, installation, testing and commissioning of Fuel Level sensor (for Low & high level) 309 MAIN LT PANEL & SUB DISTRIBUTION PANELS 310 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete withsuitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 311 INCOMING-800 Amp. MCCB-1 Nos.OUTGOINGS -1 nos. 200 AMPS TP MCCB. (25 KA)2 no. 100 AMPS TP MCCB. (25 KA)2 nos. 63 AMPS TP MCCB. (25 KA)1 nos. 200 AMPS TP MCCB. (25 KA) (for spare)1 nos. 100 AMPS TP MCCB. (25 KA) (for spare)1 nos. 63 AMPS TP MCCB. (25 KA) (for spare) 312 AUTOMATIC POWER FACTOR CORRECTION PANEL(CAPACITOR PANEL) 313 Supply, Installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 200 KVAR A P F C Panel consisting of 5 / 10 / 15 / 20 / 25 / 50 KVAR at 415 Volts (rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust &vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623All outgoings MCCBs shall be thermal-magnetic based with inbuilt O/L & S/C release.All MCCBs shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CTs, PTs, etc 314 Capacitor duty contactors should be used for switching individual capacitor banks.The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.The capacitor panel shall be integrated with the main L T Panel as per schematic diagram 315 INCOMINGIncomer circuit breaker has been included in the main panel.1 set- 3 CTs , ratio 600/5A Class 1.0 accuracy 15 VA burden formetering.1Nos- (0-600A) digital Ammeter with selector switchMicro processor based automatic power factor control relay (3phase) (including power factor meter) in 9 steps for automaticcut off or add on capacitor units to keep the power factor at0.95 with variation of loads. All associated auxiliary contactors /relays shall be provided with in the scope of work.Phase indicating lamps with HRC fuses, and indicating in eachcapacitor chamber unit to indicate On/Off status of capacitorunit.BUS BARS600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivityelectrolytic Aluminium bus bar with conductivity on min 57 to58% of suitable length, SMC / DMC supports, with colourcoding and insulated by heat shrinkable sleeves and clips onshrouds for joints. The current density of bus bar shall beminimum 1.0 sq mm / amp.The Maximum allowable temperature for the Bus bar to berestricted to 85 deg C. The temperature rise should berestricted to 35 deg C above ambient temperature. 316 OUTGOINGS -2 nos. of 125 AMPS TPN 25 KA MCCB and 150 amps AC3 dutycontactor with 50 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.2 nos. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 25 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 20 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 40 AMPS TPN 25 KA MCCB and 50 amps AC3 dutycontactor with 15 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 32 AMPS TPN 25 KA MCCB and 40 amps AC3 dutycontactor with 10 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 16 AMPS TPN 25 KA MCCB and 20 amps AC3 dutycontactor with 5 KVAR heavy duty MPP type at 415 V capacitorbank (rated Voltage 440 Volts) , auto-manual selector switch,start stop push button for manual operation including on/offindicating lamps and delay timer complete.1 SET 200 KVAR CAPACITOR PANEL 317 Electrical Panel-1 (Block-1)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamberetc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 318 Electrical Panel-2 (Block-2)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving andmounted on non hygroscopic supports such as CMC/BMCsupport withdeteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 5 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 319 Electrical Panel-3 (Block-3)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and otherparameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 813 (E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 320 Electrical Panel-4 (Block-4)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/ 812 (C)INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 321 Electrical Panel-5 (Block-5)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/813(E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 322 Lighting Panel for Basement :Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 / 811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 5 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 323 UPS O/G Panel:Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as perIS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 2 nos.40 AMP MCCB 18 no.25 AMP MCCB 18 no.40 AMP MCCB 1 no. (spare)25 AMP MCCB 1 no. (spare) 324 CO2 Gas Flooding System For Main LT PanelSupply, installation, testing and commissioning of Polymer Tube Detection based CO2 Gas Flooding System For Main LT Panel, Consisting of the following components: CO2 Cylinder, 4.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 325 CO2 Cylinder, 2.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 326 Filling adopter 327 D/I Adopter for converting the indirect valve to function as Direct System. 328 FET End of Line adapter with Pressure gauge for Automatic fireuppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives. 329 Pressure Switch to monitor Pressure drop in the tube, switchpoint 11 Bars. 330 Flexible Polymer Detection Tube made by special modified Polyamide (PA), Color Red, High grade quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, Melting Point approx. 220 degrees Celsius when heating up with 10 K/minute, Steady load tested upto max. 80° C. The lowest operating temperature is stipulated at minus 40°C. Service Pressure 20 Bar, Burst Pressure at 20 Deg C approx 120 Bars, Release Temperature : Rapid heat increase in temperature at 20 bars pressure approx 150 Deg to 180 Deg C (Without Flame) 331 Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries +electrical wiring to make each entire system functional.(Indeginous) 332 Containing all required fitting and fixing 333 Installation & Commissioning Charges includes complete setup of the system, Installation of Cylinders on specially designed brackets, Laying of sensor tubes using tube attachments and Cable ties, fixing end of line plugs and end of line adapters, pressurizing tube @ 15-18 Bars using Nitrogen pressurizingagent. 334 Supplying and fixing and connection of the following rating, four Pole MCCB (25 KA), 415 volts, at the incomer / outgoing in seperate enclosure, complete with connections, testing and commissioning etc. as required : 100 AMP FP MCCB (25 KA) micro processor based. 335 (VI) INVERTORSupply, installation, testing and commissioning of on lineUPS with builtin parallal redundancy, as per following detailsTechnology : Micro processor based controls, True on line,Double conversion type, should have cold start facility.Input :- (mains / local D G set compatibility)a) Voltage : 415 V / 3 Phaseb) Voltage Variation : - 20% to + 20%c) Input Frequency : 50 Hz.d) Frequency Variation : + 10%e) Automatic phase sequence correction facilityOutput :-a) Voltage : 230 V / 1 Phase, 415 V / 3 Phaseb) Voltage Variation : + 1%c) Frequency Variation : 50 Hz. + 0.1%Overall Efficiency : > 90%Charger : Should have built in charger to suit systemrequirement.Battery type : Sealed Maintenance Free - SMF (Global Yuasa /Exide)Battery Backup = 15 min.External battery backup will be usedDisplay : Should have LCD display with event logging facility.Upgradeability : Should be upgradeable to work as parallelredundant UPS in load sharing mode.Software Communication : Should have SNMP (Simple NetworkManagement Protocol) compatibilityRating : 30 KVA 336 SUB-HEAD - 1 : S/F MODULAR TYPE SWITCH / SOCKET & SUBMAINS 337 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.DSR 1.57 338 Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. DSR 1.14 339 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.4) 340 2 X 16 sq. mm + 1 X 6 sq. mm earth wire(DSR 1.14.6) 341 4 X 6 sq. mm + 2 X 6 sq. mm earth wire(DSR 1.14.9) 342 4 X 10 sq. mm + 2X6 sq. mm earth wire(DSR 1.14.10) 343 SUB-HEAD - 2 : DISTRIBUTION BOARDS & CIRCUIT BREAKERS 344 S/F of surface / flush mounting SPN Distribution board with additional metal door without MCB complete in all respects as directed at site by Engineer-in-charge. a) 12 WAYS CAT A (UPSOR 1025(A) 345 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. (a) 4 WAYS CAT A (UPSOR 1026 (A) 346 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. 6 WAYS : CAT A (UPSOR 1027(A) 347 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. : 8 WAYS: CAT A (UPSOR UPSOR 1028(A) 348 Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA) : CAT A(UPSOR 1002 349 Supply & fixing of 63 Amp DP MCB (10 KA) :CAT A : UPSOR 1011 350 S/F of 63 amp FP MCB (10 K.A.) :CAT A : UPSOR 1020 (A) 351 S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.UPSOR 394 352 S&F and making connection of 63 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. UPSOR 398 353 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. UPSOR 1109 354 S&F single pole MCB blanking plate UPSOR 1034(B) 355 SUPPLY AND LAYING OF CABLES & ACCESSORIES 356 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor byclamps etc UPSOR (501) 357 6 sqmm 3 core 358 10 sqmm 4 core 359 16 sqmm 4 core 360 25 sqmm 3 1/2 core 361 35 sqmm 3 1/2 core 362 50 sqmm 3 1/2 core 363 95 sqmm 3 1/2 core 364 120 sqmm 3 1/2 core 365 150 sqmm 3 1/2 core 366 185 sqmm 3 1/2 core 367 240 sqmm 3 1/2 core 368 300 sqmm 3 1/2 core 369 deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required. 370 Supply fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge (UP SOR 504) 371 6 sqmm 372 10 sqmm 373 16 sqmm 374 25 sqmm 375 35 sqmm 376 50 sqmm 377 70 sqmm 378 95 sqmm 379 120 sqmm 380 150 sqmm 381 185 sqmm 382 240 sqmm 383 300 sqmm 384 Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor UPSOR 503 385 6 sqmm 3 core 386 10 sqmm 4 core 387 16 sqmm 4 core 388 25 sqmm 3 1/2 core 389 35 sqmm 3 1/2 core 390 50 sqmm 3 1/2 core 391 95 sqmm 3 1/2 core 392 120 sqmm 3 1/2 core 393 150 sqmm 3 1/2 core 394 185 sqmm 3 1/2 core 395 240 sqmm 3 1/2 core 396 300 sqmm 3 1/2 core 397 Supply of ISI marked Copper conductor PVC insulated cable as per IS 1554 armoured, served, sheathed 1100 volts grade. : 25 sqmm 1 core 398 Laying and testing of aluminium / copper conductor cable PVC / XLPE insulated armoured, served, sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray or inside existing RCC / HDPE DWC pipe complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) / end terminations to the cable leads, insulating with tape and making connections with brass / nickle plated flame proof double compression glands, providing cable tags complete in all respect upto the satisfaction of Engineer-incharge. (The supply of terminations and glands shall be under seperate item): (a) 25 sqmm 1 core 399 Supply and laying of ISI marked Copper conductor PVC insulated control cable as per IS 1554 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including end termination, double compression glands, supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-incharge. Armoured 400 6 x 2.5 sq mm armoured (DG to Main LT panel interfacing) 401 12 x 2.5 sq mm armoured (2 runs DG controlling) 402 12 x 2.5 sq mm armoured ( For Transformer contro wiring) 403 2 x 4 sq mm armoured (for Battery charging) 404 Supply of 3 core stranded aluminium conductor 11 KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments) a) 240 sq. mm 3 core 405 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of following size in the existing masonry open duct etc. as required.a) Size exceeding 120 sq. mm. But not exceeding 400 sq. mm. 406 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 407 Supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 408 CABLE TRAY 409 Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches or installed over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.: The support for 1000mm, 900 mm and 750 mm wide cable tray will be by 50 x 50 x 6 mm MS angle, for 600mm and 450 mm wide cable tray will be by 40 x 40 x 5 mm MS angle, for 300mmwide cable tray will be by 32 x 32 x 5 mm MS angle, for 150mmwide cable tray will be by 25 x 25 x 4 mm MS angle. 410 900 mm (W) X 50 mm (H) X 2 mm (T) 411 750 mm (W) X 50 mm (H) X 2 mm (T) 412 600 mm (W) X 50 mm (H) X 2 mm (T) 413 450 mm (W) X 50 mm (H) X 2 mm (T) 414 300 mm (W) X 35 mm (H) X 1.5 mm (T) 415 150 mm (W) X 35 mm (H) X 1.5 mm (T) 416 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 417 90 mm dia (OD-90 mm & ID-76 mm nominal) (DSR 14.16.2) 418 160 mm dia (OD-160 mm & ID-135 mm nominal) DSR 14.16.4) 419 MISCELLANEOUS ITEMS EXTERNAL ELECTRICAL 420 Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.21) 421 Providing and fixing H.V. danger notice plate of 250 mm x 200 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.22 422 S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) UPSOR 1134 423 Supply and fixing of Fist aid box as approved by Indian red cross conforming to IS : 2217. 424 Supply of rubber gloves of 11 KV grade as per IS : 4770. 425 Supply and fixing of cable route maker as directed by Engg-incharge. UPSOR 505 426 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality. to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels) UPSOR 1136 427 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality to withstand 45 KV dielectric strength as per IS 15652 complete in all respects. (For 11 KV Panels) UPSOR 1136 428 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.a) 300 mm dia. DSR 14.14.4 429 Supply and erection of pregalvanized Ladder type cable trays made out 25mm x 75mm x 25mm x 2.5mm GI Section all along (as runner) and 20mm x 30mm x 20mm x 2.5 mm GI Section (as rungs) at every 250mm interval c/c including tees, bends, crossings, reducers, couplings to be laid over head on wall or hanged from ceiling including all neccessary supports, brackets (50x50x6 MS Angle) at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts &bolts complete in all respects. 430 900 mm (W) X 75 mm (H) 431 750 mm (W) X 75 mm (H) 432 EARTHING 433 BODY / SAFETY EARTHING (FOR BODY OF ALL ELECTRICAL EQUIPMENTS LIKE RISING MAINS, TRANSFORMER, DG SETS,LIFTS ETC. 434 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. Further GI strips from equipments shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel). please refer submitted drawing. 435 Providing & fixing 25mm x 5mm G.I. strip on surface, in recess or in ground including connections etc. as required (LT Panel,Cable Trays & Elevator). DSR 5.15 436 Providing & fixing 32mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (Pig tail) UPSOR 717 437 Providing & fixing 50mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (SubstationGrid) 438 NEUTRAL EARTHING 439 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound.(borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6mm. please refer submitted drawing. 440 Providing & fixing 32mm x 6mm insulated Copper strip on surface, in recess or in ground including connections etc. asrequired. 441 SOLAR PLANT 442 ON-Line Solar Photovoltaic system plant including suitable rating Poly crystalline Silicon PV Modules having a efficiency of minimum 15% (without any power export arrangement), String combiner box, DC Distribution board etc. complete as required. Scope of work also includes supply, installation of GI structure, (80 micron) in suitable section complete with all accessories and hardware including civil work as required at site for mounting PV panels.: 15 kWp SET 170 415 V, 3 phase, 50 Hz AC power string inverter (Grid intractive) with stand & all protection and controls having overall efficeiency of not less than 95%. : 15 kWp (nominal) SET 171 AC distribution board made of 2 mm CRCA sheet, power coated having IP55 degree of protection (for indoor installation) for terminating 415 V, 3 phase, 50 Hz power suppled from inverter complete height with following multifunction: - Digital multifunction meter (EM 6400 of Schnieder or equal) - 40 Amp TPN MCB (10 KA) - Phase indicating lamps. SET 1Lighting Arrestor SET 1Surge Protector SET 1 443 STREET / EXTERNAL LIGHTING 444 Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.(UPSOR 653) 445 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect.Category AAA (UPSOR 1455) 446 Supply and fixingof LED Street light Fitting having die cast aluminium body and diffuserwith driver set suitable for 45 watt to 50 Watt. Confirmingto IP 65 and above protectioncomplete in all respect.Category AAA (UPSOR 1443) 447 Supply and fixingof 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminiumbody with drive set . Confirming to IP 65 and above Protection complete in all respect.Category AAA (UPSOR) MR 448 Supply and fixingof 3 Watt to 4 Watt LED Spot/Spike light Confirming to IP 65 and above Protection complete in all respect. Category AAA (UPSOR 1441) 449 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect.Category AAA 450 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation,excavation & back filling and Required T&P completee in all respect. 451 Supply installation, testing and commissioning of 3x2.5 sqmm flexible fire retardant copper connecting wire of required length from MCB in cable junction box of pole to luminaire along with MCB & Connector complete as required. 452 Supply & burrying of 40 mm dia x 4.50 m long G.I. pipe vertically for earthing having 12 mm dia holes spaced 75 mm apart drilled upto 2 meter brom the bottom complete with one earthing lead of no. 6 to 8 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switchboard (from apron to switch board the cost of GI pipe & GI wire will be extra), 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect. 453 Supply & burrying of 600mm x 600 mm x 6.0 mm G.I. plate, vertically for pole earthing with its top at least 3 m below ground level complete 20mm dia. G. I. pipe and funnel for watering and one earthing lead of no. 8 to 10 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . 454 Supplying & Laying of one number 8 SWG G. I. wire in 15 mm. dia. G. I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P and other material required for proper completion of the work as directed at site. 455 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 456 INCOMER : 457 f (ii) 40 AMP TPN MCB (10 KA) 458 e (ii) 25 AMP TPN MCB (10 KA) 459 OUT GOINGS : 460 4 nos. 6-32 AMP DP MCB (10 KA) 461 24 nos. 6-32 AMP DP MCB (10 KA) 462 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 10 sqmm 3 core 463 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Size not exceeding 35 sq. mm. 464 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Size not exceeding 35 sq. mm. 465 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe etc. as required. Size not exceeding 35 sq. mm. 466 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. e) 6 sqmm 3 core 467 Deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
39.
Heavy Industries and Public Enterprises #9463652 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area Naini Prayagraj (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required. (as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 13 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 16 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 18 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 19 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (as per UPPWD approved make list) 20 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (as per UPPWD approved make list) 21 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (as per UPPWD approved make list) 22 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 24 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 25 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 26 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 29 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 30 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 31 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required (as per UPPWD approved make list) 32 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 33 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 34 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 35 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.(as per UPPWD approved make list) 36 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 37 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 38 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 39 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard.(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer along with Photo Biological Safety Standard. (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 45 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 46 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (as per UPPWD approved make list) 47 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 48 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 50 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 51 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 52 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 53 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 54 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 55 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 57 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. Incomer100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos, 100/5A 5VA class 1 resin cast CT - 1 set Outgoing. 63 A FP 10 kA MCB - 2 nos. , 40 A DP 10 kA MCB - 20 nos.(as per UPPWD approved make list) 60 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 63 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 66 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 67 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 68 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection(as per UPPWD approved make list) 69 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I.(as per UPPWD approved make list) 70 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 74 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 75 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 76 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 77 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect.(as per UPPWD approved make list) 78 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 79 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(61) dated 22.10.2020(as per UPPWD approved make list) 80 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023(as per UPPWD approved make list) 81 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 82 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 83 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia (as per UPPWD approved make list) 84 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 85 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates as per previous sanctioned Estimate Job No. ED-1(61) dated 22.10.2020 (as per UPPWD approved make list) 86 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properly connected with earth conductor by clamps etc. (Havells,Polycab,Grandlay,Gloster,KEI) 87 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 88 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size. rate as per sanctioned vide Job no. ED-I (83) Dt. 25.11.2021(as per UPPWD approved make list) 89 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. (as per UPPWD approved make list) 90 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kg(as per UPPWD approved make list) 91 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I. (as per UPPWD approved make list) 92 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I. 93 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I. (as per UPPWD approved make list) 94 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I. (as per UPPWD approved make list) 95 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. 96 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I. (as per UPPWD approved make list) 97 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications. (as per UPPWD approved make list) 98 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor (as per UPPWD approved make list) 99 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 185 sq.mm 3 core 11 KV HT XLPE Cable (Havells,Polycab,Grandlay,Gloster,KEI) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB). ( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021 (as per UPPWD approved make list) 103 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P. (as per UPPWD approved make list) 104 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल ) (as per UPPWD approved make list) 105 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect. (as per UPPWD approved make list) 109 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (as per UPPWD approved make list) 110 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 111 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I.. (as per UPPWD approved make list) 112 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 113 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I. (as per UPPWD approved make list) 114 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I. (as per UPPWD approved make list) 115 Supply & Installation of Top Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 116 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 117 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I. (as per UPPWD approved make list) 118 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work. (as per UPPWD approved make list) 119 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I. (as per UPPWD approved make list) 120 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 121 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 122 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 123 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 124 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Havells,Polycab,Grandlay,Gloster,KEI) 125 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(Havells,Polycab,Grandlay,Gloster,KEI) 126 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe)(Havells,Polycab,Grandlay,Gloster,KEI) 127 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Havells,Polycab,Grandlay,Gloster,KEI) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core (Havells,Polycab,Grandlay,Gloster,KEI) 132 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 133 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 134 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 135 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 140 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 141 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 142 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 143 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 151 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge. (as per UPPWD approved make list) 152 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 153 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 154 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge.(as per UPPWD approved make list) 155 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 156 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 157 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 158 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to Nagar Nigam Store as per direction of E/I. (as per UPPWD approved make list) 159 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge. (as per UPPWD approved make list) 160 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge. (as per UPPWD approved make list) 161 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge. (as per UPPWD approved make list) 162 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work. (as per UPPWD approved make list) 163 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P. (as per UPPWD approved make list) 164 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect. (as per UPPWD approved make list) 165 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I. (as per UPPWD approved make list) 166 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe.(as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
40.
Public Administrative Department #9460902 Technical Bid
Tender for phase-2 construction and development work of Dev Van in Vineet Khand, Gomti Nagar Scheme.,1 KIDS PLAY EQUIPMENTS ( ref. senior citizen park) 2 Supplying and Fixing of Standered Multi seater See Saw outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPSS12, Make Fun Play/ Kompain/ Arihant) PSR 3 Supplying and Fixing of Turbo Tower outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPCL35 , Make Fun Play/ Kompain/ Arihant) PSR 4 Supplying and Fixing ofMonkey Climber outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPCL43, Make Fun Play/ Kompain/ Arihant) PSR 5 Supplying and Fixing of Balancing Bridge outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge. (Model No. FPTH41, Make Fun Play/ Kompain/ Arihant) PSR 6 Supplying and Fixing of Four Seater Merry Go Round outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPMR11, Make Fun Play/ Kompain/ Arihant) PSR 7 Supplying and Fixing of7 Ht. FRP Wave Slide outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPSD51, Make Fun Play/ Kompain/ Arihant) PSR 8 Supplying and Fixing of Frog Bin - FRP outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPDB11, Make Fun Play/ Kompain/ Arihant) PSR 9 Supplying and Fixing of Imperial Bench 4 outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPGD11, Make Fun Play/ Kompain/ Arihant) PSR 10 HORTICULTURE 11 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). DSR Horticulture 2020; 2.25 12 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 13 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). DSR Horticulture 2020; 2.8RA 14 Fine dressing of the ground DSR Horticulture 2020; 2.7, RA 15 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. DSR Horticulture 2020; 2.25 16 Plantation Work 17 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) DSR Horticulture 2020; 2.57 RA 18 Hedge Plant /Ground cover 2.57.3 19 Grass Cover 20 Providing & laying Selection no. 1 doob grass turf with earth 50mm to60mm thickness of existing ground prepared with proper level and rammingwith required tools wooden and than rolling the surface with light rollermake the surface smoothen and light watering the same maintenance for30 days or more till the grass establish properly,as per direction of officer in charge DSR Horticulture 2020; 2.34 21 EDGE SHRUBS AROUND STRUCTURES AND PATHWAYS 22 Providing and stacking of Iresine herbstii, of height 20-30 cm. full of branches well developedin 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020;10255 23 Bush Rose in different colour 2 to 3 healthy branch 30 cm and above ht. well developed with8 or more flowers / flower buds in 20 cm Earthen pot / Plastic pot as per direction of theofficer-in-charge. DSR Horticulture 2020;4.90 24 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen potsof size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-char DSR Horticulture 2020;8.14 25 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020; 6.7 26 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marrypalmar, Cherry Blossom etc. well developed with fresh & healthy bushy infull bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of theofficer-in-charge. DSR Horticulture 2020; 5.12 27 FLOWER GARDEN 28 AlyssumDSR Horticulture 2020; 10.1.1 29 Brachycome 10.1.4 30 Daisy hybrid 10.1.15 31 Dahlia double 10.1.14 32 Salvia Hybrid different colour 10.1.29 33 Gomphrena 10.2.5 34 Kochia 10.2.6 35 Portulaca hybrid 10.2.7 36 Vinca Hybrid 10.2.9 37 Zinnia hybrid 10.2.10 38 CIVIL WORK 39 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil DSR 2023, 2.6 40 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. DSR 2.25 41 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) (PWD SOR 2021/SI-4.1.8) 42 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc for mass concrete DSR 5.9.1 (UP SOR 8.20) 43 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 6.4.2 44 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 13.4.1 45 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 13.46.1 46 Making bajri path including preparation of subgrade, supplying and laying brick aggregate of 50 mm nominal size 7.5 cm deep with blinding material consisting of 12 mm moorum and 12 mm red bajri consolidated with road roller. PWD SOR 2021/ 16.10 47 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but Excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All Work Above Plinth Level DSR 5.33A 48 Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. -Thermo-Mechanically Treated bars.PSR 49 Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete DSR 11.35 50 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR 10.2 51 Providing wood work in frames of / Railing / false ceiling, partitionsetc. sawn and fixed in position with necessary stainless steel screws etc. Sal woodDSR 9.3.1 52 French spirit polishing :Two or more coats on new works including a coat of wood fillerDSR 13.68.1 53 Painting or Vanishing on iron works in small areas or new wood work with One coat of ready mixed priming paint & Two coats of approved superior ready mixed paint of clear syuthetic varnish including supply of all materials, labour and T & P etc. required for proper completion of work. Paint to be used should confirm to the I.S.I. No. 103 1950. DSR 13.67.1 54 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate SOR 2020-21 55 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.3.3 Sanction Rate 56 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.10.3 Sanction Rate 57 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 58 brick ballast 40 mm class 150PWD SOR 59 brick ballast 40 mm class 150 PWD SOR 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) 61 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. PWD 16.64 62 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate, PWD 11.3.1 63 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mmPWD 11.41A.1.3 64 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.2 65 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.PWD 22.6 66 SEATING 67 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications including, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge PSR ( AYAPPA PHASE 1) 68 DUSTBINS 69 Providing & fixing of Dustbin made in mild steel frame with painting & polish and frame wooden member fixed in m.s. frame including painting polishing as per drawing & design all complete in direction of engineer in charge.PSR REF. from Khargapur 70 EXTERNAL LIGHTING AND ELECTRICAL 71 Supply and fixing of 3500mm decorative ribbed steel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8 & with having for twin nos bracket. The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 72 Supply and fixing of 534 mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore or equivalent repuateted make Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 73 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required sor 2018 E &M708 74 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.DSR5.7(E&M) 2014 75 Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)PWD 711 E-M 2018 SCHEUDLE 76 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD 501,E-M 2018 SCHEUDLE 77 6.00 Sqmm 4 Core (g) 78 25.00 Sqmm 3.5 Core (J) 79 70.00 Sqmm 3.5 Core (M) 80 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN PWD 807 f 81 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) (PWD SOR 2021/SI-4.1.8) 82 Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. .(PWD SOR 2021/SI-4.3.2) 83 PAINTING 84 Painting of graphics on the wall till 2 - 2.5 meter s in height in specific designs and colors as guided by engineer in charge PSR 85 SPEAKER SYSTEM ( REF. FROM BEGUM HAZRAT MAHAL) 86 Supplyinstallationtesting andcommisioning of weatherised Two-Way 5.25 inch (135mm) Coaxial Speaker with Components:• 5¼” highly weather-resistant driver• ¾” soft-dome highly weather-resistant tweeter and can handle 80WPinkNoise PowerHandling(160Wprogram)indirect8Ώ setting, plus built-in 30W 70V/100V multi-tap transformer, should have Fully isolated center chamber for wiring protection, Frequency Response (-10 dB): 55 Hz - 18 kHz; (±3 dB): 65Hz - 16 kHz;PowerRating1:160WcontinuousProgram(2hrs),80W (320W peak), Continuous Pink Noise (2 hrs), 45 W (180W peak) Continuous Pink Noise (100hrs), Maximum Input Voltage: 23.3 V,Sensitivity2:86dB,1W@1m(ave.80Hz-16kHz),Nominal Coverage Angle: 360° horizontal, 160° vertical (primary listening 10°to 50°upfromground),Directivity Index(DI):3.4dB, Maximum SPL 3: 105 dB @ 1m, Low Frequency Driver: 135 mm (5.25in)diameterLFdriver,Kapton™former,35.5mm(1.4in) voice coil, polypropylene cone and polyurethane surround, High Frequency:19mm(0.75in)diameterHFdriverPolyetherimide (PEI) dome. Complete in all respects and as directed by engineer in charge. (JBL/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 87 Supply, installation, testing and commissioning ofAmplifiers for Main Speakers with Four-channel 2400 WattNetwork amplifier withDSPwithClassD/TDtechnology,PowerHandling:4× 2400W @ 4/8 Ohms, 4 × 950 W @ 16 ohms Max power per channel in case of bridge mode / Power managmenet should be 4200watts @ 4 ohms and 4800 watts @ 8ohms,InputSignaltoNoiseRatio >108dB,LoadImpedance Stereo/Dual Mode 2Ω - 16Ω; 70Vrms and 100Vrms 96KHz SampleRate; DSPFeatures:classic/linear-phase/FIRspeaker processing platform with four throughputs; DSP Features: Group control with Raised Cosine MESA EQ asymmetric filters Peak and RMS limiters, Support Multiple make Speaker presets Comprehensiveclockingmanagementsystemwithlowlatency samplerateconversion;ProtectionFeatures:VeryHigh Frequency Protection ,DirectCurrentProtection ,Short Circuit Protection,Temperatureprotectionetc,Eightdual-redundant Dante network audio inputs, 4 Analog Inputs, Control port Certifictaion:CE,ETL(ANSI/UL,CSA),BIS.(Crown/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 88 Supplying,installationTestingandCommissioningof2Cx4sq mmCopperSpeakerCableinPVCConduitofspecifiedmake, complete with all accessories etc complete as as per the attached approved make list and with proper connections etccomplete in all respect as directed by Engineer-in-charge.. 89 Supplying,installationTestingandCommissioningof2x2.5sq mmCopperSpeakerCableinPVCConduitofspecifiedmake, complete as per the attached approved make list and with proper connections etccomplete in all respect as directed by Engineer-in-charge.. MR 90 Supply,Installation,testingandcommissioningofSpeakercagemade of SS Jali for theft protection. complete in all respect as directed by Engineer-in-charge.. MR 91 Supply, Installation,testingand commissioningofPoE Ethernet Controllerwith minimum8programmablebuttonandVolume Control,dual-gang US Decoraor dual-gang EU formfactor, push/rotary encoder, encoder ring, with sleep functionality, supportminimum2LCDscreenhaving64x128pixelsscreen resolution, Configured within Audio Architect via drag-and-drop, powerconsumption300mAmaxat48VDCwithVW-1Rated. (JBL/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 92 SURVILLANCE SYSTEM 93 PLINTH AREA RATES CPWD 2023, Supply installation , testing and commissioning of IP based CCTV system for building security comprising of PTZ/FIXED CAMERA, CABLING , RECORDING , DISPLAY SYSTEM HARDWARE SOFTWARE SUPPORT,FOR EXTERNAL SURVILLANCE 6.10.2 , For two entrances only 94 INTERNAL ELECTRICAL WORKS 95 GATE 96 WIRINGPOINTS 97 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 98 Same as in item no. 1 but for fan. and light duty exhaust fan (AS PER UPPWD -2018) 140 B 99 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 100 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187 A 101 Add for plug point with modular switch & socket in place of piano type switch & socket. (AS PER UPPWD -2018) 187 C 102 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 103 MAINS & SUBMAINS 104 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 105 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221 B 106 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 107 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 108 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 109 12 WAYS CAT-B (AS PER UPPWD -2018) 1025A 110 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 111 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 112 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 113 EARTHING 114 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 115 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 116 CABLES 117 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 2core (AS PER UPPWD -2018) 501 118 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm.(AS PER UPPWD -2018) 504 119 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018) 503 120 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects.(AS PER UPPWD -2018) 1120 121 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 122 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect.(AS PER UPPWD -2018) 1402 123 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 124 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 125 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep (M.R.) 126 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 127 LIBRARY AND SHOP 128 WIRINGPOINTS 129 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 130 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 131 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 132 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187 A 133 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 134 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 135 MAINS & SUBMAINS 136 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 137 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221B 138 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223B 139 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 140 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 141 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 142 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 143 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 144 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B(AS PER UPPWD -2018) 1033 145 EARTHING 146 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 147 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 148 CABLES 149 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 2core (AS PER UPPWD -2018) 501 150 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 151 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018) 503 152 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 153 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 154 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018) 1402 155 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 156 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 157 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 158 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm M.R. 159 HALL (ELECTRICALINSTALLATIONS) 160 WIRINGPOINTS 161 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 162 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 163 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 164 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187A 165 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 166 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 167 MAINS & SUBMAINS 168 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 169 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221 B 170 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018)223 B 171 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 172 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 173 12 WAYS CAT-B (AS PER UPPWD -2018)1025 A 174 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018)1002 175 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018)1010 176 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018)1033 177 EARTHING 178 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . (AS PER UPPWD -2018)703 179 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site.(AS PER UPPWD -2018)721 180 CABLES 181 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 182 10 sqmm 2core (AS PER UPPWD -2018)501 183 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 184 10 sq.mm. (AS PER UPPWD -2018)504 185 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 186 10 sqmm 2core (AS PER UPPWD -2018)503 187 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018)1120 188 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018)1122 189 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018)1413 190 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 191 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 192 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm M.R. 193 LIBRARY AND SHOP (ELECTRICALINSTALLATIONS) 194 WIRINGPOINTS 195 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 196 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 197 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 198 Add for light / fan points with modular type switches in place of piano type switches(AS PER UPPWD -2018) 187 A 199 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 200 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 201 MAINS & SUBMAINS 202 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 203 2 x 4 sq. mm.In 20 mm dia conduit.(AS PER UPPWD -2018) 221 B 204 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 205 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 206 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 207 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 208 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 209 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 210 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 211 EARTHING 212 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 213 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 214 CABLES 215 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.10 sqmm 2core 501 216 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 217 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018)503 218 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 219 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 220 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018)1402 221 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 222 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 223 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 224 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 225 GUARD ROOM (ELECTRICALINSTALLATIONS) 226 WIRINGPOINTS 227 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 228 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 229 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 230 Add for light / fan points with modular type switches in place of piano type switches(AS PER UPPWD -2018) 187 A 231 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 232 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 233 MAINS & SUBMAINS 234 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 235 2 x 4 sq. mm.In 20 mm dia conduit.(AS PER UPPWD -2018) 221 B 236 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 237 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 238 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 239 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 240 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 241 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 242 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 243 EARTHING 244 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 245 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 246 CABLES 247 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.10 sqmm 2core 501 248 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 249 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018)503 250 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 251 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 252 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018)1402 253 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 254 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 255 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 256 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 257 LIBRARY (PLUMBING WORKS ) 258 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 259 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 260 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 261 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 262 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 263 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps.M.R. 264 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. M.R. 265 HALL PLUMBING WORKS 266 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 267 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 268 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 269 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 270 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 271 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 272 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 273 KITCHENPLUMBING WORKS 274 ACCESSORIES 275 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : PWD 19.7 (DAR17.10) 276 Providing and fixing the taps attached to the shower divertor and the the sink M.R. 277 Providing and fixing the shower heads M.R. 278 Providing and fixing the shower divertersM.R. 279 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia (for wash basin) PWD 17.28.1.1 280 WATER SUPPLY PIPES AND FITTINGS 281 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 282 Internal work exposed on wall 283 40mm nominal outer dia pipes. (PWD 18.75) 284 50mm nominal outer dia pipes PWD 18.9.6 285 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 286 Concealed work including cutting chase and making good the wall etc. 287 15mm nominal outer dia pipes PWD 18.8.1 288 20mm nominal outer dia pipes PWD 18.8.2 289 25mm nominal outer dia pipes PWD 18.8.3 290 32mm nominal outer dia pipes PWD 18.84 291 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 292 40 mm nominal bore PWD 18.17.3 293 50 mm nominal bore PWD 18.17.4 294 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions.DSR 18.21.2.1 295 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. PWD18.49.1 296 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. PWD 18.50.1 297 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931.PWD 18.52.1 298 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. PWD 18.53.1 299 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredRange of four urinal basins with 10 litre white P.V.C. automatic flushing cistern PWD 17.4.4 300 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard designDSR 18.32.1 301 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm. size P type PWD 19.4.2.1 &19.4.2 302 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms DSR 17.70.1 303 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 304 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD 18.48 305 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 306 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) M.R. 307 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 308 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 309 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 310 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 311 50 mm dia. 312 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 313 P-Trap type Floor Trap 110 x 75 mm 314 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 315 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 316 GUARD ROOM AND TOILET BLOCK PLUMBING WORKS 317 ACCESSORIES 318 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : PWD 19.7 (DAR17.10) 319 Providing and fixing the taps attached to the shower divertor and the the sink 320 Providing and fixing the shower heads 321 Providing and fixing the shower diverters 322 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 323 32 mm dia (for wash basin) PWD 17.28.1.1 324 WATER SUPPLY PIPES AND FITTINGS 325 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 326 Internal work exposed on wall 327 40mm nominal outer dia pipes 18.7.5 328 50mm nominal outer dia pipes 18.9.6 329 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 330 Concealed work including cutting chase and making good the wall etc. 331 15mm nominal outer dia pipes 18.8.1 332 20mm nominal outer dia pipes 18.8.2 333 25mm nominal outer dia pipes18.8.3 334 32mm nominal outer dia pipes 18.8.4 335 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 336 40 mm nominal bore 18.17.3 337 50 mm nominal bore 18.17.4 338 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. 18.21.2.1 339 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 18.49.1 340 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms.18.50.1 341 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 18.52.1 342 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931.18.53.1 343 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredRange of four urinal basins with 10 litre white P.V.C. automatic flushing cistern 17.4.4 344 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 18.32.1 345 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm. size P type PWD 19.4.2.1 &19.4.2 346 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms DSR 17.70.1 347 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 348 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD 18.48 349 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 350 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) 351 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 352 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 353 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 354 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 355 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 356 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 357 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
41.
Public Administrative Department #9460897 Technical Bid
Tender for construction work of Kalyan Mundap at Khasra No. 55, Daud Nagar, Faizullaganj, Lucknow., 1 Shelter House (Part - A) 2 Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 Constuction of subgrade with material obtained from avaliable land (for local earth work) Construction of embankment with approved material obtained from avaliable land as pormited and approved by engineer-in-chage and as per technical specification clause 301.3.4.1 with all lifts and leads, spreading grading to required slope and compacting to meet requiredment of table 300.0 and 300.2 as per technical specification clause 301.5 with centre up to 15 km.(by Analysis) 4 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 em deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 7 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion@ 7.51itres I sqm ofthe vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 11 Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 12 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. 13 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 14 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 15 Centering and shuttering including strutting, propping etc. and removal of form for staircases (including landing) 16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 or more. 17 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 up to plinth level) 18 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum(M-25 above plinth level) 19 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 20 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 21 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 22 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) 23 Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 24 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm 25 Providing and Fixing Ist quality ceramic glazed wall tiles conforming to IS :15622 (thickness to be specified by the manufacturer), of approved make in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm , including pointing in white cement mixed with pigments of matching shade complete. 26 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. 27 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 28 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 29 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 30 Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 2.5 metre). 31 Fixed window I ventilator without mullion I transom. Using R 1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre) (UPVC Window) 32 Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). (UPVC Window) 33 Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above). (Height above 1.8 metre) (UPVC Window) 34 Providing and fixing lSI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including lSI marked Stainless Steel butt hinges with necessary screws 35 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 36 Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete. 250x16mm 37 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10mm 38 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100mm 39 Providing and fixing aluminium hanging floor door stopper, lSI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper 40 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 41 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1 .4 mm wide aperture with matching wood beading 42 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 43 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 44 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 45 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10x 160 mm 46 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 47 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 48 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 49 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 50 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 51 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 52 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 53 6 mm cement plaster to ceiling of mix : 1:3 (1 Cement : 3 fine sand) 54 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 55 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 56 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 57 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats 58 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 59 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. 60 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(c) The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixedslurry. 61 Supplying and Stacking Filling sunken floor with over burntjhama brick aggregate 120mm to 40mmincluding compacting of materials complete as specified and directed for all levels. 62 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm 63 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm 64 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2845 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement 5 coarse sand) admixed with water proofing compound conforming to IS: 2845 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs (c) After two days of proper curing applying a second coat of cernent slurry using 2.75 kg/ sam of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1) cement 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth With average thickness of 120 mm and minimum thickness at khurra as 65 mm 65 FIRE FIGHTING (PART - B) 66 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 67 (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 68 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 69 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 70 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 71 450 lpm at 35 m Head 72 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 73 Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet 74 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 75 Providing, laying,of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia 76 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia 77 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia 78 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 79 INTERNAL HYDRANT 80 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal 81 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal 82 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 83 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required Gun metal: 84 Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926 Make: NEWAGE 85 Fire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h)with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating 86 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe 87 SUBHEAD-II :FIRE EXTINGUSHER 88 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and wheel type valve with initial Charge as per IS: 15683:2018 specification, bearing ISI Mark & EIL approved. Make: SAFEX Capacity 4.5KG 89 Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge. Capacity 6KG 90 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 91 SUBHEAD-III : FIRE CONTROL PANELS 92 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panelMCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. Same as above item but following mountings. INCOMER:- 1 Nos. 100 Amps. 4P MCCB ( 35 KA) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASSBUS BARS: 150 Amps. TP&N aluminium bus bars OUT GOINGS:-2 Nos.25 Amps. TPN MCB (10 KA) 93 Copper Power Cables, Solid Copper Conductor upto 6 sq. mm & Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured (Glavanised wire for cables up to 10x1.5 sq. mm, 8x2.5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm & balance all galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098 4 Core X 10 sqmm. Aluminium Armoured 94 Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 4 Core X 10 sqmm. Aluminium Armoured 95 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 96 6 C x 2.5 Sqmm 97 2 C x 2.5 Sqmm 98 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 99 25 mm Conduit 100 32 mm Conduit 101 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. 102 INTERNAL, EXTERNAL PLUMBING WORKS & DRAIN (Part - C) 103 SANITARY INSTALLATIONS & C.P FITTINGS 104 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 105 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 106 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 107 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge 108 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 109 Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore 110 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge. 111 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) (15 mm nominal bore 112 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 113 Providing and fixing toilet paper holder : C.P. brass 114 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) .15 mm nominal bore 115 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet : 150 mm diameter 116 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore 117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 118 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 119 Upvc WASTE & VENT PIPES AND FITTINGS 120 Providing and fixing in floor and wall face Ringfit SWR PVC Conventional system for soil and waste water pipes conforming toType B including jointing with seal ring. (i) Double socketed pipes. 121 110mm dia SWR P.V.C. pipe 122 90mm dia SWR P.V.C. pipe 123 Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof 124 Providing and fixingcPVC pipes complete with cPVCfittings and clamps, including cutting and making good walls etc. ( for wash basin waste ) 32mm dia nominal bore 125 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc.(a) for 100mm dia pipe. 126 Providing & fixingUPVC Coupler 127 a) 110 mm dia. 128 b)90 mm dia. 129 Providing and fixing trap of self cleansing design with screwed down or hinged grating with hopper complete, including cost of cutting and making good the walls and floors : (a) 100mm inlet & 90mm outlet. 130 Providing and fixin SWR PVC. 90° elbow withincluding fittings complete. 131 a) 110mm 132 b) 90mm 133 Providing and fixing 45° elbow withincluding fittings complete. 134 a) 110mm 135 b) 90mm 136 Providing and fixing SWR PVC T Band with access doorincluding fittings complete. 137 110x110x110mm 138 90x90x90mm 139 Providing and fixing SWR PVC Y including fittings complete. 140 110x110x110mm 141 90x90x90mm 142 Providing and fixing END CAP withincluding fittings complete. 143 a) 110mm 144 b) 90mm 145 Providing and fixingcast iron terminal guard. 146 110 mm 147 INTERNAL RAIN WATER DRAINAGE WORK 148 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia(SW pipe) 149 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 150 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 151 Coupler 110 mm 152 Bend 87.5 degree 110 mm Bend 153 Shoe (Plain) 110 mm Shoe 154 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 155 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 156 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 157 INTERNALWATER SUPPLY WORKS 158 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 159 20mm dia nominal outer dia pipes 160 25mm dia nominal outer dia pipes 161 32mm dia nominal outer dia pipes 162 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..Internal work & external 163 20mm dianominal bore 164 25mm dianominal bore 165 32mm dia nominal bore 166 40mm dia nominal bore 167 Providing and fixing gun metal gate valve with wheel of approved quality. 168 20mm dia nominal bore 169 25mm dia nominal bore 170 32mm dia nominal bore 171 40mm dia nominal bore 172 EXTERNALSEWERAGE & RAIN WATERSYSTEM 173 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 174 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter 175 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe 176 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design : 150 mm.dia. RCCPipes 177 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 178 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 179 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 180 Extra for depth for manholes:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 181 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 182 EXTERNAL DRAIN 183 Earthworkinsurfaceexcavationnotexceeding30 cm indepth but exceeding 1.5m in width as well as 10 sq.m. on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m, as directed by Engineer-in-Charge:All kind od soil. 0.30 m & Above 184 Providing and laying in posotion cement concrete of specifiedgrade excluding the cost of centering and shuttering - All workup to plinth level. 1:5:10 ( 1 cement : 5 coarse sand {zone-III} : 10 graded stone aggregate 40mm nominal size) 185 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 186 Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the workand including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. 187 Centering and shuttering including strutting, propping etc. and removal of form for foundation footing bases bo column etc for mass concrete etc. for mass concrete. 188 BORE WELL 189 External W/S arrangements with T.W. boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements etc . 190 6 PVC casing pipe of ISI mark. 191 P/ F 2 GI pipe (B) class. 192 Nylon mesh for filter. 193 Plastic dori. 194 Solvent cement. 195 6 End cap. 196 6 Submersible cap. 197 2 MS clamp (Heavy). 198 2 GI elbow. 199 2: X 6 GI nipple. 200 1.5 HP 9 Stage submersible pump of ISI mark with automatic panel. 201 2.5 sqm. Submersible cable. 202 Drilling charges for 6 dia tubewell. 203 Pea Gravel. 204 2 MS socket. 205 Cartage of material upto site. 206 INTERNAL ELECTRIFICATION WORK (Part - D) 207 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B 208 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 209 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 210 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 211 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 212 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 213 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 214 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 215 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 216 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 217 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 218 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 219 20 mm 220 25 mm 221 32 mm 222 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 223 Supplying and fixing brass batten/ angle holder including connection etc. as required. 224 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 225 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 1 or 2 Module (75mmX75mm) 226 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 227 Telephone socket outlet 228 TV antenna socket outlet 229 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1Pair 230 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 231 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 232 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 233 Lighting Fixtures (Lights/Fans) : 234 Supply, Installation, Testing and commissioning of 1200 mm sweep BEE 5 star rated, ceilingfan with Brush Less Direct Current(BLDC) motor class of insulation:B, 3 nos blades, 30 cm long down rod, 2nos canopies shackle kit safety rope copper winding, Power factor not less than 0.9, service valur minimum 6.00, Air delivery min 210 Cum/Min, 350 RPM THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts washers, temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz single phase AC supply, earthing etc complete as required (i) BEE 5 Star rated-1200 mm sweep 235 Armoured Cables (Cable/Gland/Lug) : 236 Supplying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 237 size 10 sq mm x 2 core 238 size 10 sq mm x 4 core 239 size 16 sq mm x 4 core 240 size 35 sq mm x 3-1/2core 241 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm 242 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 243 Upto 35 sq. mm 244 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 245 Upto 35 sq. mm 246 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 247 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 248 2 X 10 sq. mm (19mm) 249 4 X 10 sq. mm (25mm) 250 4 X 16 sq. mm (28mm) 251 3½ X 25 sq. mm (28mm) 252 3½ X 35 sq. mm (32mm) 253 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm 254 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm 255 Earthing Work : 256 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 257 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 258 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 259 L.T. Switch Panel Board : DBs & MCBs : 260 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 261 Single pole 262 Triple pole and neutral 263 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 264 40 A 265 63 A 266 Supplying and fixing following way, surface/recess mounting vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link , earth bar, din bar for mounting MCBS but without MCBs and incomer as required 8 way(4+24) , Double door 267 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 268 8 way (4 + 24), Double door 269 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 270 Miscellaneous Items : 271 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 272 Supply and Fixing of shock treatment chart.prescribedas per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. 273 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 274 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 275 Non-Schedule Items 276 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 277 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 278 CCTV WORK (Part - E) 279 SITC of 2 MP Dome Camera, 1/2.8 Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), H.265+/ H265/ H.264+ & H.264, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE, Support mobile monitoring 280 SITC of 2 MP Bullet Camera 1/2.8 Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), 2.8mm/F2.0 lens (4/6mm optional), H.265+/H265/H.264+ & H.264, IP67, DWDR, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE,Support mobile monitoring 281 Supply, Installation, Testing & Commissioning of 24Channel Network Video Recorder with specifications as follow: Supported Image Format H.264+/H.264, H.265+/H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 32; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 2x 8TB can be installed. Certification: UL, CE, BIS, FCC. 282 24 Port POE Switch ,Unmanaged PoE, 24 100M PoE, 1 1000M PoE, 1 1000M SFP, 250m Transmission, 6KV Surge Protection, 225W 283 SITC of 2U Rack with complete accessories. 284 Supply , Installtion , Testing and Comissioning of CAT6Apatch cord 3 feet for rack side switch to jack panel connectivity. Approved Makes:Belden/Siemon/Panduit/Derwiser/ Rit 285 SITC of 8 TB Survillance Hard Disk 286 Supply and laying of CAT 6 UTP cable 287 Supply and laying of 25mm dia PVC conduit including accessories. 288 SITC of 49 flat screen FHD professional LED suitable for 24x7 operation with remote control and wall mount unit/floor stand complete with making connection etc as per list of approved makes. 289 STREET POLE WITH LED LAMP & HIGH MAST (Part - F) 290 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single Arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. 291 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 80 Watt. Confirming to IP 66 Protection complete in all respect. 292 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 293 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.3 output (1output per phase) and suitable for three phase supply 294 Supply & fixing of anticlimbing device fabricated from G.I.(flat) of 25 mm x 6mm size in a shape of ring of the pole size, having G.I. flat pointed fins of length 225 mm in 8 nos. including all the materials, labour, T&P and other material required for proper completion for work and to the satisfaction of Engineer-in-Charge. 295 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. CAT. - AAA 296 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size 297 size 6 sq mm x 3 core 298 size 10 sq mm x 4 core 299 size 25 sq mm x 3-1/2core 300 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed, underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable 301 size 6 sq mm x 3 core 302 size 10 sq mm x 4 core 303 size 25 sq mm x 3-1/2core 304 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 305 size 6 sq mm 306 size 10 sq mm 307 size 25 sq mm 308 Earthing Work : 309 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required 310 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required 311 D.G. SET 30 KVA (Part - G) 312 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping.Supplying, installation, testing and commissioning of Silent Type DG Sets,AMF Panel, Bus Ducting/ Cables from DG Sets to Essential Panel, Synchronizing Panel where required, DG Set enclosure room sound insulation/ventilation/smoke exhaust as required, Earthing of DG Set system, control cabling, Fuel tank/piping, DG set Exhaust piping/Exhaust Chimney as per CPCB norms, Civil works connected with DG Sets including Foundation as required. DG Set Compatible for synchronising Panel30 KVA 313 Supply and fixing of M.S. Fencing frame duly fabricated from M.S. angle iron 50mm x 50mm x 5mm /40mm x 40mm x 5mm with M.S. flat 40 x 6 mm with M.S. welded 10 SWG, Mesh Jali best quality 25 x 25 mm on fencing frame with 6 Nos. M.S. Fasteners of required size duly painted complete in all respects. The Fencing frame of different sizes as site requirement. 314 Add Extra For RCC Foundation Work for D.G. Set Including Cost of Exaust Pipe with Structure and Other Misc. Work and T&P etc. Complete in all respect as per directed by Engineer In-Charge. 315 Earthing System : 316 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 317 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 318 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as requiredide. 319 Boundary Wall & Entrance Gate (Part - H) 320 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lifts up to 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m. - in ordinary soil . 321 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 322 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 323 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 324 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 325 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 up to plith level) 326 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 above plinth level) 327 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 ormore. 328 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1 :6 (1 cement : 6 coarse sand) 329 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 Cement : 6 coarse sand) 330 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm). 331 Making Groove in plaster 10 to 12 mm wide x 8mm deep in plaster vertically or horizontally as required . 332 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 333 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 334 Interlocking Tiles (Part - I) 335 Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per technical specification clause-401 336 Providing and Laying of interlocking concrete Block pavement having thicking 80 mm as per drawing and technical specification Clause 1504. (Exclusive G.S.B.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Uttar Pradesh View Result →
42.
Heavy Industries and Public Enterprises #9460660 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area, Amausi (Part-1) District Lucknow Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 13 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 16 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 18 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 19 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 21 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 22 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 24 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required.(as per UPPWD approved make list) 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 26 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 29 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 30 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 31 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.(as per UPPWD approved make list) 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 34 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 35 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required.(as per UPPWD approved make list) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete asrequired.(as per UPPWD approved make list) 37 Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc.complete as required.(as per UPPWD approved make list) 38 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 39 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 44 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.)(as per UPPWD approved make list) 46 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 47 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 50 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 51 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 52 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 53 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 54 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 55 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 57 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 59 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 60 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 62 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 63 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 65 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 66 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 67 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I.(as per UPPWD approved make list) 68 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 69 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 70 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 74 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 75 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect.(as per UPPWD approved make list) 76 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 77 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate(as per UPPWD approved make list) 78 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate (as per UPPWD approved make list) 79 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 80 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 81 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia(as per UPPWD approved make list) 82 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 83 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates as per previous sanctioned(as per UPPWD approved make list) 84 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Havells, Polycab, Grandlay, Gloster, KEI make) 85 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 86 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. (as per UPPWD approved make list) 87 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021(as per UPPWD approved make list) 88 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 89 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 90 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 91 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 93 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 96 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 97 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 300 sq.mm 3 core 11 KV HT XLPE Cable (Havells, Polycab, Grandlay, Gloster, KEI make) 98 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc.. 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list)(Havells, Polycab, Grandlay, Gloster, KEI make) 99 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB).( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 103 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size. rate as per sanctioned vide Job no. ED-I (83) Dt. 25.11.2021(as per UPPWD approved make list) 104 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. Rates as per sanctioned vide job no.ED-1 (83) Dt. 25.11.2021(as per UPPWD approved make list) 105 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 106 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021 (11KV भूमिगत केबल )(as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 110 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 111 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints. 300 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 112 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 113 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 114 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 115 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I.(as per UPPWD approved make list) 116 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I.(as per UPPWD approved make list) 117 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I.(as per UPPWD approved make list) 118 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 119 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I.(as per UPPWD approved make list) 120 Supply & Installation of Top Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 121 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 122 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I.(as per UPPWD approved make list) 123 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 124 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I.(as per UPPWD approved make list) 125 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 126 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 127 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.. Main LT Panel #1 INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 128 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 129 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.. Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 130 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Havewlls, Polycab, Grandlay, Gloster, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(Havewlls, Polycab, Grandlay, Gloster, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Havells, Polycab, Grandlay, Gloster, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Havells, Polycab, Grandlay, Gloster, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 136 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 137 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Havells, Polycab, Grandlay, Gloster, KEI make) 138 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core (Havells, Polycab, Grandlay, Gloster, KEI make) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 145 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 146 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 155 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 156 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 157 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 158 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed atsite by Engineer in charge.(as per UPPWD approved make list) 159 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 160 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 161 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 163 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 164 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 165 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable)(as per UPPWD approved make list) 166 Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P.(as per UPPWD approved make list) 167 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 170 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work.(as per UPPWD approved make list) 171 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 172 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 173 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 174 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
43.
Heavy Industries and Public Enterprises #9460658 Technical Bid
tender for Electrical Upgradation Of Upsida Industrial Area, Ram Nagar Phase-I And Ii, Chandauli (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required. (as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 10 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 11 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 13 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 14 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 16 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 17 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 18 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (as per UPPWD approved make list) 19 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (as per UPPWD approved make list) 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (as per UPPWD approved make list) 21 Supplying and fixing brass batten/ angle holder including connection etc. as required. (as per UPPWD approved make list) 22 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 23 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 24 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door (as per UPPWD approved make list) 26 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 27 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 28 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 29 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 30 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required (as per UPPWD approved make list) 31 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required. (as per UPPWD approved make list) 32 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.(as per UPPWD approved make list) 34 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.(as per UPPWD approved make list) 35 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 36 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 37 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 38 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 39 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture (Make-Bajaj, Philips, Wipro, Crompton) 40 Supply,installation, testing andcommissioning of24W Surface Mounted Round Led Downlighter delivering minimum system lumen of 2400 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white with Optics: HET Diffuser. Ingress Protection should be IP20. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 41 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories. (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty) (as per UPPWD approved make list) 45 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (as per UPPWD approved make list) 46 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 47 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply (as per UPPWD approved make list) 48 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 49 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 50 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 51 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (as per UPPWD approved make list) 52 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 53 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 54 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required (as per UPPWD approved make list) 55 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 56 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 57 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos.(as per UPPWD approved make list) 58 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. Incomer100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos, 100/5A 5VA class 1 resin cast CT - 1 set Outgoing. 63 A FP 10 kA MCB - 2 nos. , 40 A DP 10 kA MCB - 20 nos.(as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 60 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 63 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 66 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness (as per UPPWD approved make list) 67 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection(as per UPPWD approved make list) 68 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I. (as per UPPWD approved make list) 69 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area.complete in all respect as per direction of E/I. (as per UPPWD approved make list) 70 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I. (as per UPPWD approved make list) 71 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I. (as per UPPWD approved make list) 72 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I. (as per UPPWD approved make list) 73 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I. (as per UPPWD approved make list) 74 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED (as per UPPWD approved make list) 75 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M (as per UPPWD approved make list) 76 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules completein all respect. (as per UPPWD approved make list) 77 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification. (as per UPPWD approved make list) 78 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(61) dated 22.10.2020 (as per UPPWD approved make list) 79 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023 (as per UPPWD approved make list) 80 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I. (as per UPPWD approved make list) 81 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect. (as per UPPWD approved make list) 82 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps.i) 100mm dia (as per UPPWD approved make list) 83 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete inall respect as per direction of E/I. (as per UPPWD approved make list) 84 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I(as per UPPWD approved make list) 85 Supply and laying of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 86 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 87 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework. Rates (as per UPPWD approved make list) 88 Lettering with black japan paint of approved brand and manufacturer (as per UPPWD approved make list) 89 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 90 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area.complete in all respect as direction of E/I. (as per UPPWD approved make list) 91 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I. (as per UPPWD approved make list) 92 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P ,men material for completion of Work complete in all respect as direction of E/I. (as per UPPWD approved make list) 93 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I. (as per UPPWD approved make list) 94 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect. UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 95 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I. (as per UPPWD approved make list) 96 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications. (as per UPPWD approved make list) 97 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor (as per UPPWD approved make list) 98 Supply and laying of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 99 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection.(A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB). )Make-ABB, Schneider, Siemens, Crompton Greaves) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection.(A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB). Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection.(A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB). Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. (as per UPPWD approved make list) 103 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 104 Lettering with black japan paint of approved brand and manufacturer (11KV भूिमगत केबल )(as per UPPWD approved make list) 105 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable(as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable(as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable(as per UPPWD approved make list) 108 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect. (as per UPPWD approved make list) 109 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (fromappron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thickalround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also).Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (as per UPPWD approved make list) 110 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as requiredcomplete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 111 Deigging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I. (as per UPPWD approved make list) 112 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 113 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 114 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I.(as per UPPWD approved make list) 115 Supply & Installation of Top Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 116 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I.(as per UPPWD approved make list) 117 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I.(as per UPPWD approved make list) 118 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 119 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I.(as per UPPWD approved make list) 120 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect. UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 121 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 122 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting,M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Main LT Panel #1INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos. (as per UPPWD approved make list) 123 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. Sub LT PanelIncomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 124 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type (as per UPPWD approved make list) 125 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 126 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe)(as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 127 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe)(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe)(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(as per UPPWD approved make list)(Polycab, Grandlay, Gloster, Havells, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core(as per UPPWD approved make list) (Polycab, Grandlay, Gloster, Havells, KEI make) 134 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core(as per UPPWD approved make list) 135 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core(as per UPPWD approved make list) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core(as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core(as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core(as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core(as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core(as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core(as per UPPWD approved make list) 142 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm(as per UPPWD approved make list) 143 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm(as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm(as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm(as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm(as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm(as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm(as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm(as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm(as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm(as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm(as per UPPWD approved make list) 153 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V gradesingle core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed (as per UPPWD approved make list) 154 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal)(as per UPPWD approved make list) 155 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal)(as per UPPWD approved make list) 156 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 157 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used)(as per UPPWD approved make list) 158 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable(as per UPPWD approved make list) 159 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used)(as per UPPWD approved make list) 160 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to JE store as per direction of E/I.(as per UPPWD approved make list) 161 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 162 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 163 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable, Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 164 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <=0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstruction cement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work.(as per UPPWD approved make list) 165 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 166 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 167 Supply , installation of 5 zone central control unit (main frame) configured for 512 station,connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 168 Supply & Laying of 6Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 corepower cable in 50mm Dia HDPE Pipe.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
44.
Heavy Industries and Public Enterprises #9460652 Technical Bid
Tender For Electrical Upgradation Of Upsida Industrial Area, Partapur, Meerut (Part-1) Under Aiim-2, 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 2 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C(as per UPPWD approved make list) 3 Wiring for twin control light pointwith 1.5 Sq.mm FRLS PVC insulatedcopperconductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(as per UPPWD approved make list) 4 Wiringforlight /powerplugwith 2 x 4 Sq.mm. FRLS PVC insulated, copper conductor single core cable insurface / recessed medium class PVCconduitalongwith 1 no. 4 Sq.mm FRLS PVC insulated copper conductor single core cable forloopearthing as required.(as per UPPWD approved make list) 5 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.(as per UPPWD approved make list) 6 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (as per UPPWD approved make list) 7 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 8 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 9 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire (as per UPPWD approved make list) 10 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 11 Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire (as per UPPWD approved make list) 12 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (as per UPPWD approved make list) 13 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm (as per UPPWD approved make list) 14 Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (as per UPPWD approved make list) 15 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 150 mm X 150 mm X 60 mm deep (as per UPPWD approved make list) 16 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 200mm x 150mm x 100mm deep (as per UPPWD approved make list) 17 Supplying and fixing of METAL BOX following sizes (nominal size) on surface or in recesss with suitable size of phenolic laminated sheet cover in front including painting etc as required. 250mm x 300mm x 100mm deep (as per UPPWD approved make list) 18 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 19 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 20 Supply and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(as per UPPWD approved make list) 21 Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(as per UPPWD approved make list) 22 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.(as per UPPWD approved make list) 23 Supplying and fixing brass batten/ angle holder including connection etc. as required.(as per UPPWD approved make list) 24 Supplying and fixing 20 A, 240 volts, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (as per UPPWD approved make list) 25 Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, C curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required.. single pole (as per UPPWD approved make list) 26 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. (as per UPPWD approved make list) 27 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 6 way, Double door(as per UPPWD approved make list) 28 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). 8 way, Double door(as per UPPWD approved make list) 29 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 8 way, Double door (as per UPPWD approved make list) 30 Supplying and fixing followingway Single pole and neutral, sheet steel, MCB distribution board , 240volts on surface / recess, completewithtinned copper bus bar, neutral bus bar, earth bar,dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator). 16 way, Double door (as per UPPWD approved make list) 31 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps (as per UPPWD approved make list) 32 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (as per UPPWD approved make list) 33 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required(as per UPPWD approved make list) 34 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 2 nos 3 pin 5/6 amps modular socket outlet and 2 nos 5/6 amps. modular switch, connection etc. as required.(as per UPPWD approved make list) 35 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (as per UPPWD approved make list) 36 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 37 Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. (as per UPPWD approved make list) 38 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (as per UPPWD approved make list) 39 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (as per UPPWD approved make list) 40 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. (as per UPPWD approved make list) 41 Supply,installation, testing andcommissioning of2ft 10W LED Batten delivering an initial system lumen of 1000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 6500K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.9 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 42 Supply,installation, testing andcommissioning of 4ft 20W LED Batten delivering an initial system lumen of 2000 lumens & the luminaire shall be with system efficacy ≥ 100 lm/W. The housing should be made of Extruded Aluminium with polycarbonate diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , PF ≥ 0.95 ,THD ≤ 10%, 50,000 Hrs LED Life with L70 Criteria and Ingress Protection of IP20. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture(Make-Bajaj, Philips, Wipro, Crompton) 43 Supply,installation, testing andcommissioning of18W Surface Mounted Round Led Downlighter delivering minimum system lumen of 1800 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing is Pressure Die Cast Aluminium, powder coated white. IP20 , Optics: HET Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered with isolated type electronic driver in polycarbonate / metal enclosure with input voltage range of 100 to 265V , THD ≤ 10% & PF ≥ 0.90, 50,000 Hrs LED Life with L70 Criteria. The LED Driver shall be of same make and made in India for ease of repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer (Make-Bajaj, Philips, Wipro, Crompton) 44 Supply,installation, testing andcommissioning of 10W Bulkhead delivering minimum system lumen of 1000 lm& the luminaire shall be with system efficacy ≥ 100 lm / W. Housing & Rim is Pressure Die Cast Aluminium. The Luminaire shouuld have ingress protection of IP65 and IK rating of IK08along with Opal Polycarbonate Diffuser. The operating CCT shall be 5700K with CRI of ≥80. The luminaire shall be BIS Registered and should have input voltage range of 140 to 280V along with THD ≤ 10% & PF ≥ 0.95. The Luminaire shouuld have a life class of 50,000 Hrs LED Life with L70 Criteria. Luminaire shall have minimum surge protection of 2.5KV. The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacturer(Make-Bajaj, Philips, Wipro, Crompton). 45 Supply,installation, testing andcommissioning of Aviation obstruction light with LED lamp, toughened clear glass, with all accessories as per standard item with all accessories.(Make-Bajaj, Philips, Wipro, Crompton) 46 Supply of AC230/250 volts, 50 HZ exhaust fanincluding providingnuts, bolts, mounting frame, Louvers shutters and other accessories etc.complete . 250-300 mm sweep (Heavey Duty)(as per UPPWD approved make list) 47 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(as per UPPWD approved make list) 48 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep (as per UPPWD approved make list) 49 Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & Off of street lights at sun set & sun rise or twilight (Auto ON, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. . 3 output (1 output per phase) and suitable for three phase supply(as per UPPWD approved make list) 50 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 51 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 200 mm dia (OD-200 mm & ID-175 mm nominal) (as per UPPWD approved make list) 52 Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 53 Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(as per UPPWD approved make list) 54 Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required.. 1 or 2 Module (75mmX75mm) (as per UPPWD approved make list) 55 Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required.. one run (as per UPPWD approved make list) 56 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required(as per UPPWD approved make list) 57 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. Telephone socket outlet (as per UPPWD approved make list) 58 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.. TV antenna socket outlet (as per UPPWD approved make list) 59 Supply, Installation, Testing & Commissioning ofBuilding Panel cubicle type, made out of min 2mm thick CRCA sheet (load bearing), totally enclosed, IP42, free standing, floor mounting, dust and vermin proof, powder coated, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene / PU gasket, IS 8623etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification. iNCOMER100/125A FP 35kA MCCB with each havingmicroprocessor basedrelease with adjustable OL, SC and EF protection - 1 nos. Busbar1 Set of 150 A TPN busbars of high conductivity electrolytic quality Aluminium alloy and suitable size earthing conductor through out the panel for its earthing. Instruments each2A, C curve SP MCB - 3 nos.RYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F, kW, kWh, Acc class 1.100/5A 5VA class 1 resin cast CT - 1 setOutgoing.63 A FP 10 kA MCB - 8 nos. 40 A DP 10 kA MCB - 4 nos. (as per UPPWD approved make list) 60 Supply, Installation, Testing & Commissioning of Streetlighting panel, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, free standing, floor mounting, dust and vermin proof, powder coated, outdoor type, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, rotary handle, spreaders, 3mm thick gland plate, hinged type door with neoprene gasket, IS 8623 etc. The panel shall include supply & installation of following switchgears, metering instruments and accessories as per specification.Incomer63A, TPN, switch disconnector unit (Isolator), AC23, 415V, 50Hz, complete with handle assembly having door interlock - 1 no. Busbar1 Set of 100 A TPN busbars of high conductivity electrolytic quality Aluminium alloy. Instruments2A, C curve SP MCB - 3 nosRYB indication lamp, LED type - 3 nos.1 No 3 phase Digital Multi function meter to read V, A, F Acc class 1.63/5A 5VA class 1 resin cast CT - 1 setOutgoing.40A TP+NL C curve MCB -8 nos.16A SP+NL C curve MCB -3 nos.Necessary space provision and control wiring for satisfactory operation of Astronimical time switch for automatic switching ON & OFF of street lights.(as per UPPWD approved make list) 61 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 2 core (as per UPPWD approved make list) 62 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 10 sqmm 4 core (as per UPPWD approved make list) 63 Supply and laying of ISI marked aluminium conductor FR XLPE insulated cable as per IS 7098, &cable, armoured, served, sheathed1100 volts grade. 50 sqmm 3 1/2 core (as per UPPWD approved make list) 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) (as per UPPWD approved make list) 65 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm) (as per UPPWD approved make list) 66 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.. 3.5 x 50 Sq mm (35 mm) (as per UPPWD approved make list) 67 Supply and installing following size of perforated hot dipped GI cable trays(galvanisation thickness not less than 50 microns) with perforations not more that 17.5% in convenient sections, jointed with connectors, suspended from the ceiling with GI suspenders / fixed to walls with suitable GI clamps, including bolts and nuts, bends, reducers, Tees, cross members etc as required.150 mm width x 50 mm depth x 1.6 mm thickness(as per UPPWD approved make list) 68 SITC of 5/6 KVA 1 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS,with isolationtransformer,with 26Ahx x 16 nos SMF Batteries for back up, with required cabling for incoming & outgoing connection (as per UPPWD approved make list) 69 Supply & Erection of Steel rail/steel tubular pole bottom G.I. complete with 1/6th of over all length of pole in cement concrete with one foot square /one fit dia cement plinth alround the pole above ground level. The foundations of underground will be of cement concrete in the ratio of 1:2:4. The Stone ballast/ Brick- ballast used will be 1.25cm (1/2X1) size with stone pad 30x30x7.5cm, at the base, including all material, labour & T&P required for the proper completion of work including C.I. Cap. 410 SP -55/ 227Kgcomplete in all respect as per direction of E/I. (as per UPPWD approved make list) 70 S/F of Straight M.S. Channel 125x65 mm (10.7 Kg./M) 3.2 M long as per design for cross area. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 71 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 72 S/Fixing angle iron 50x50x6mm (4.5Kg./M) length as per design for bracing of the D.P. Structure.complete in all respect as per direction of E/I.(as per UPPWD approved make list) 73 S/Fixing clamp suitable for securing then channel as above item with the poles made out of MS flat 50x6mm including all bolts, nuts, washer etc. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 74 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole. complete in all respect as per direction of E/I.(as per UPPWD approved make list) 75 Supply, Stringing, tensioning, jointing and binding of all sizes of G.I. / G.S. wire on Steel tubular poles. The binding of G.I. / G.S. wore shall be done with the specified size of G.I. wire or as per direction of Engineer-In-Charge on the specified countings on the poles. Weight of G.I. /G.S. Wire is to be determined by measuring taut horizontal distance between centres of two adjacent pole and compounding the weight of wire by using a standard table of weights of G.I. /G.S. wire. 2% extra may be added for sag at the direction of the Engineer-In-Charge. All inclusive of T& P, Men & material for proper completion of works as per direction of Engineer-In Charge of work/site and in street adhrence to Drg and Work No. UPSIDC/ED(as per UPPWD approved make list) 76 Painting of Support and allmountings on it with two/three coats of alluminium paints with an under cost of Red-oxide paint on length of the supports above the ground level or as per direction of Engineer-in-charge of work/site, inclusive of all T& P , Men & material for proper completion of work. B) Pole Above 10M(as per UPPWD approved make list) 77 Supply and fixing danger board fabricated from 10 No. gauge M.S. Sheet as per I.E. Rules complete in all respect. (as per UPPWD approved make list) 78 Supply & fixing of anticlimbing device fabricated from G.I. flat of 25 mm X 6mm size in a shape of ring of the polesize , having G.I. flat pointed fins of length 225mm in 8 Nos. and also barbed wire in 200mm length above the said ring, including material labour and T&P required for Proper completion of the work as per specification.(as per UPPWD approved make list) 79 S/F of 33KV with 11KVA 4Nos. Set B&S type strain disc insulators 120KN E&M strength complete in all respects as per direction of E/I. Busbar in two section (Jaishree,Bhel,RR,WS, Rama make) (as per UPPWD approved make list) 80 S/F of 33KV pin insulator with pin on main terminal gantry, as per direction of E/I (jaishree,bhel,RR, WS, Rama make) rates as per previous sanctioned estimate job no. ED-1(296) dated 07.11.2023(as per UPPWD approved make list) 81 Supply & Installation of 33 KV F-Bracket with clamp nut & bolt complete in all respect as per direction of E/I.(as per UPPWD approved make list) 82 Supply & grouting of stay rod, complete with all its components specified here-in -under and supply & fixing of stay clamps including all bolts, nuts, washers etc. to the pole along with binding nozzling and requisite tensioning of stay wire of under given size together T&P men & material for proper completion of work as per direction of Engineer- in-charge of work/site and strict adhrerrence to Drawingwork no. UPSIDC/ED/ complete in all respect.(as per UPPWD approved make list) 83 Supply & fixing of G.I. pipe B class for climbing up the cable from ground to overhead line including all accessories, materials, labour and T& P required for proper completion of the work as per specification but excluding cost of clamps. i) 100mm dia (as per UPPWD approved make list) 84 S/F of M.S. Clamp made out of 50x6mm M.S. Flat for securing G.I. pipe with S.T. Pole complete in all respect as per direction of E/I.(as per UPPWD approved make list) 85 S/F of P.G. clamp suitable for Panther/Dog/Weasel Conductor for jumpering completein all respect as per direction of E/I rates(as per UPPWD approved make list) 86 Supply , Laying , Testing & Commissioning of 3 core standered aluminiumconductor 300 sq.mm 3 core 33 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11KV/33 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc. (Grandlay, Gloster, Polycab, Havells, KEI make) 87 Providing and fixing of precast reinforced cement concrete 1:1.5:3 (1 cement: 1.5coarse sand: 3 gradedstone aggregate 20mm nominal size ) Kilometer stone as per standard design including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work concrete in foundation painting and lettering etc. which shall be paid for separately 35X93.5X10cm size.(as per UPPWD approved make list) 88 Finishing with epoxypaint (two coat or more coat) at all location prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface etc. complete on concretework.(as per UPPWD approved make list) 89 Lettering with black japan paint of approved brand and manufacturer rates as per sanctioned vide Job no. ED-I(83) Dt. 25.11.2021(as per UPPWD approved make list) 90 Supply and making of 33 KV, 3x300 sq.mm XLPE Cable outdoor heat shrinkable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. (as per UPPWD approved make list) 91 S/F of Straight M.S. Channel 100x50 mm (7.9 Kg./M) 2.24 M long as per design for cross area. complete in all respect as direction of E/I.(as per UPPWD approved make list) 92 Supply & fixing of VShape M.S. Channel 75X 40mm (6.8Kg/M) as per design for cross-arm including all T&P & Men & material for proper completion of work complete in all respect as per direction of E/I.(as per UPPWD approved make list) 93 Supply & fixing 11KV disc & fittings on cross arm/clamp fixed on S.T. poles includingall T& P , men material for completion of Work complete in all respect as direction of E/I.(as per UPPWD approved make list) 94 Supply & fixing 11KV pin with insulator on cross-arms fixed on S.T. Poles including all T&PMen & material for proper completion of work. complete in all respect as direction of E/I.(as per UPPWD approved make list) 95 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I.(as per UPPWD approved make list) 96 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as direction of E/I.(as per UPPWD approved make list) 97 Dismantling & regrouting of street light /LT line 12 tilt/sick bend/ STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 4no. Support of 65X65X6 mm or higher size MS angle in suitable length with help of welding/cutting withgrouting as per technical specifications.(as per UPPWD approved make list) 98 Supply, Sagging , tensioning , jointing & binding of specified ACSR Conductor including cost of Al. tape, binding wire & jointing sleeves etc. standard table weight of the conductor shall be taken by measuring span from pole centre to centre and giving and allowance of 3% for sag , jumpers & cut lengths.The rate includes the cost of P.G.Clamps bindng wires, alluminium tape & jointing sleeves if required. All inclusive of T&P , men & materialfor proper completion of the work as per direction of Engineer-in-charge. d) ACSR Dog Conductor(as per UPPWD approved make list) 99 Supply, laying, Testing & Commissioning of following size 11 KV HT XLPE Cable (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cablesconfirming to I.S. 7098 (Part-II with latest amendments) 11 KV grade at a depth of 900 mm below ground level in Existing HDPE/MS Pipe. The armouring of cable shall be properlyconnected with earth conductor by clamps etc..185 sq.mm 3 core 11 KV HT XLPE Cable(Grandlay, Gloster, Polycab, Havells, KEI make) 100 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Five ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and4 Nos. outgoing 630Amp VCB) with SCADA compatible.( Make-ABB, Schneider, Siemens, Crompton Greaves) 101 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) four ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 3 Nos. outgoing 630Amp VCB) with SCADA compatible. ( Make-ABB, Schneider, Siemens, Crompton Greaves) 102 Supply, erection, Installation, testing & commissioning of RMU (Ring main Unit) Three ways 630Amp. 12KV rating (FPI type) with metering components (CT & PT) suitable for operation on 11 KV, 3 Phase, 50Hz AC Supply free Standing floor Mounting totally enclosed dust, tight , bermin proof outdoor type sheet steel clad switch disk connector with locking device interlock for cable components comprising of following components, including construction of plinth suitable for substation make ABB,Schneider, Seimens, Crompton, with all O/C and E/F self powered protection. (A) 11KV outdoor type RMU in the 11KV ring with FPI (fault passage indicate) and auxiliary power & metering components with following configuration (1 No. Incomer 630Amp. VCB and 2 Nos. outgoing 630Amp VCB) with SCADA compatible.( Make-ABB, Schneider, Siemens, Crompton Greaves) 103 Supply & fixing of welded wire mesh fencing of 5X3X2.4Meter and 2X2.4M gate including excavation base concrete & brick work with back filling etc. complete in all respect. Rates as per sanctioned vide job no. ED-I (83) Dt.25.11.2021(as per UPPWD approved make list) 104 Numbering of HT Pole etc with black enamel paint after making suitable size base with the help of yellow enamel paintof approved brand as technical specification, appropriate priming coat, preparation of surface and including cost of material, men and T&P.(as per UPPWD approved make list) 105 Lettering with black japan paint of approved brand and manufacturer (11KV भूमिगत केबल )(as per UPPWD approved make list) 106 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Outdoor Terminations 185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 107 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I. Indoor Terminations185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 108 Supply and making of following size outdoor heat shrinkable jointing kits/Straight through joints for 11 KV XLPE Cable after carefully removing the insulation of the cable duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes,cotton tape,plumbing material and lugs etc. complete in all respect as direction of E/I.Straight Joints185 sq.mm 3 core 11 KV HT XLPE Cable (as per UPPWD approved make list) 109 S/B of 40 mm dia x 4.5 mtr. long G.I. pipe vertically for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. from the bottom complete with earthing lead of no.6 to 8 SWG GI wire in G.I.pipe upto appron upto switch board 30 cm square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect.(as per UPPWD approved make list) 110 Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing (This will apply for earthing of poles also). (as per UPPWD approved make list) 111 Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. complete in all respect as direction of E/I. (as per UPPWD approved make list) 112 Digging of depth of 900 mm below ground level over a cushion of 100mm thick five river sand all around on protect with wall bricks on sides and and on top put acrosscomplete in all respect as direction of E/I. (as per UPPWD approved make list) 113 Supply and insatallation, testing & commissioning of outdoor type Aluminium wound oil cooled transformer of rating 63 KVA, 11/0.4 KV Alum. wound as Technical specification of UPPCL complete in all respect as per direction of E/I. (as per UPPWD approved make list) 114 Supply & fixing of 11KV TPMO Set with Polymer Insulator complete in all respect as per direction of E/I.(as per UPPWD approved make list) 115 Supply & fixingof3phase DO Set complete in all respect as per direction of E/I. (as per UPPWD approved make list) 116 Supply & Installation of Top Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 117 Supply & Installation of Dropper Channel complete in all respect as per direction of E/I. (as per UPPWD approved make list) 118 Supply & Installation of MS Angle 75x75x6x2028mm complete in all respect as per direction of E/I. (as per UPPWD approved make list) 119 Supply & fixing straight M.S. Channel 100X50mm (7.9Kg./M) 1.15 M long as per design for cross-arm includingall T& P & Men & material for proper completion work.(as per UPPWD approved make list) 120 Supply & Installation of Clamps with Bolt & Nut complete in all respect as per direction of E/I. (as per UPPWD approved make list) 121 Supply & Installation of 11 KV F-Bracket with clamp nut & bolt complete in all respect.UPPCL RESSPO Annexure 1 (Pt. 07) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 122 Supply & fixing MS Earthing Rod Earthing having 20mm dia and 2540mm long suitable for ST Pole complete in all respect as per direction of E/I. (as per UPPWD approved make list) 123 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Main LT Panel #1INCOMER: 800 Amp. MCCB-1 NoOUTGOING: 200 Amp.MCCB-3 Nos., 100 Amp.MCCB-1No & 63 Amp.MCCB-1No (as per UPPWD approved make list) 124 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Main LT Panel #1INCOMER: 630 Amp. MCCB-1 NoOUTGOING: 200 Amp. MCCB-2 Nos. 100 Amp-MCCB-1 No& 63 Amp. MCCB-2 Nos.(as per UPPWD approved make list) 125 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.Sub LT Panel Incomer 200 Amp. TPN-1 NoOutgoings 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos.(as per UPPWD approved make list) 126 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc.The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp onincoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle typeswitch board shall be of cat A B & B-II and pedestal type for Cat-B and C only..Incoming100 Amp. TPN-1 NoOutgoing(a) 63 Amp. TNP-2 Nos. (ii) Cat. B. Cubicle Type(as per UPPWD approved make list) 127 Supply, Installation & commissioning of 40A TPN Centralized Group control Monitoring/CCMS street light control Panel having communication technology of GSM/GPRS/3G/4G/5G, real time clock with battery backup, controller power consumption <10 W, operating voltage 140 to 270V AC, built in surge protection 4 kv, External surge protection 40kv , Ingress protection IP55, having self protection from short circuit, over voltage, overload, Trip /events and anti theft alert provision. The cubical of panel painted with anti-corrosive alkali and acid proof powder coated paint suitable for Pole/Wall/ Structure mounting provision complete in all respect. (Including SaaS Charges) complete in all respect as per direction of E/I. (as per UPPWD approved make list) 128 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 10 sq.mm 4 core(Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 129 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.16 sq.mm 4 core (Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 130 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.25 sqmm 3.5 core(Cable laid in Ex. DWC Pipe) (Grandlay, Gloster, Polycab, Havells, KEI make) 131 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.70 sq.mm 3.5core(Grandlay, Gloster, Polycab, Havells, KEI make) 132 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge.95 sq.mm 3.5 core (Grandlay, Gloster, Polycab, Havells, KEI make) 133 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 120 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 134 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 240 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 135 Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground levelin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)..over a cushion of 75 mm. thick sand all around and protected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.OEM must have its own in house NABL accrediated Laboratory for testing procedure. All Material as per Technical specificition pre approved by Engineer in charge. 300 sq.mm 3.5 core(Grandlay, Gloster, Polycab, Havells, KEI make) 136 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 10 sq.mm 4 core (as per UPPWD approved make list) 137 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 16 sq.mm 4 core (as per UPPWD approved make list) 138 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 25 sq.mm 3.5core (as per UPPWD approved make list) 139 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 70 sq.mm 3.5core (as per UPPWD approved make list) 140 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 95 sq.mm 3.5 core (as per UPPWD approved make list) 141 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 120 sq.mm 3.5 core (as per UPPWD approved make list) 142 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 240 sq.mm 3.5 core (as per UPPWD approved make list) 143 Supply & fixing of following size brass nickle plated compression gland for PVC insulated & armoured served sheathed underground cable including rubber ring etc. complete in all respect. brass nickle plated compression gland for PVC insulated cable complete in all respect. 300 sq.mm 3.5 core (as per UPPWD approved make list) 144 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 10 sq. mm (as per UPPWD approved make list) 145 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 16 sq. mm (as per UPPWD approved make list) 146 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 25 sqmm (as per UPPWD approved make list) 147 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 35 sq. mm (as per UPPWD approved make list) 148 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 50 sq. mm (as per UPPWD approved make list) 149 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 70 sq. mm (as per UPPWD approved make list) 150 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 95 sq. mm (as per UPPWD approved make list) 151 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 120 sq. mm (as per UPPWD approved make list) 152 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 150 sq. mm (as per UPPWD approved make list) 153 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 240 sq.mm (as per UPPWD approved make list) 154 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge 300 sq. mm (as per UPPWD approved make list) 155 Supply and Wiring of submains with two nos. of 2.5 sq.mm.FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by Engineer in charge.(as per UPPWD approved make list) 156 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 160 mm dia (OD-160 mm & ID-135 mm nominal) (as per UPPWD approved make list) 157 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.T&P. 63 mm dia (OD-63 mm & ID-51 mm nominal) (as per UPPWD approved make list) 158 Dismantling of damaged ST Pole which cause to any accident of men & UPSIDA property in industrial area including cost of men and T&P and shifting to store charge. (as per UPPWD approved make list) 159 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. ACSR conductor (old & used) (as per UPPWD approved make list) 160 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge.LT Cable & AB Cable (as per UPPWD approved make list) 161 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. GI Earth wire(old & used) (as per UPPWD approved make list) 162 Dismantling of HT/LT Network Pole, Conductor, double pole structure, over head cable , existing street lights network on Main approcah Road including cartage and shifting to Store upto 1.0km as per instruction of Engineer in charge. HT Cable (33KV or 11KV Cable) (as per UPPWD approved make list) 163 Safely Dismantling of existing street lights including PVC Cable, bend pipe, clamp etc. from ST pole including cost of men and T&P with cartage site to JE store as per direction of E/I.(as per UPPWD approved make list) 164 Supply,Installation,Testing and Commissioning of Wall or Floor Mounted type 3.3 kW/230V,50Hz Electric Vehicle Chraging Station having 3-Pin socket(single)/Outpot- 3.3 Kw/16 Amps, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App,, SIM/Wi0Fi/GSM/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 165 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 7.2 kW to 7.5 kW Charger AC Single phase Type-2 AC charger, Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 166 Supply, Installation, Testing and Commissioning ofWall or Flooe Mounted type 22 kW Charger 415V, 50 Hz, Type-2 AC, 32A outpot, with attached single Gun & cable Cummunication Protocol RFID/OTP/MQTT/OCPP or higher, user Authentication via App, LAN/4G SIM/Wi-Fi/Bluetooth Suport complete with PI65 Protection,Surge protection, Earth fault protection and connection cable , Installation & other associated work including cost of all material,freight,Men and T&P. The Charger should be compatible with all electric vehicles copper power cable, stand & canopy, fabrication of foundation other associated work including cost of all material,freight, Men and T&P. as per technical specification approved by Engineer in charge.(as per UPPWD approved make list) 167 Supply, Installation , Testing and Commissioning of 7.0 MeterAutomatic boom barrier with RFID system comprising Hydraulic pumpunit , Plunger pistons, balancing by compression spring ,internal stopsadjustable for open or close beam positions ,System operating Voltage 230 ± 10 % Volt, AC 50 Hz, Reverse/Forward Motor, working power supply 24 V.D.C,including UHF RFID reader with pole5.0 KV online UPS ofMin. 30 minute back up for the Barrier . The Boom raise/lower time <= 0.8 sec ,Stand alone with push Button switch & wirelessremote control and cable with on/off switch and Remote can be integrated with Access,Control system with card, Key and Biomentic as per tender specification ,Optical beam sensor / photo cell be provided to prevent barrier from closing on the vehicles.Twin Channel Exit Push putton for open close with green and red Buttons.The control unit is housed in weather proofhousing with IP 54/ IP 55 Enclosure including cost ofconstructioncement/ concrete foundation, Y shape Barrier arm rest fixure, RFID tokens, Supply & fixing of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs,tags, identifiers, fixures, clamps, screws, nut - bolts etc. Men and T&Pas required for completion the work. (as per UPPWD approved make list) 168 Supply, Installation, Testing and Commissioning ofmulticolur traffic LED light of polycarbonate, 24 V DC Micro Controller based Traffic Signal Controller mounted in IP-65 M.S Powder coated Panel , 24V DC RED FULL LED Traffic Light with 300mm Polycarbonate housing.4V DC AMBER FULL LED Traffic Light with 300mm Polycarbonate housing, 24V DC GREEN Arrow LED Traffic Light with 300mm Polycarbonate housing, M.S powder coated Junction Box with terminal connectors,M.S clamps for fitting lights and suitable poleof approved material having upto 3 mm thikness with 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling complete in all respect including cost of all material,men and T&P.(as per UPPWD approved make list) 169 Supply, Installation, Testing and Commissioning of AIR QUALITY MONITORING SYSTEM/(OCEMS) With LED Display board of Size 6.0x4.0 ft or higher having Data logger(RS485 based), PM 2.5 Sensor, Pm 10 sensor, SO2 Sensor, CO2 Sansor, NO2 Sansor, CO Sensor, Noise& Smoke Sensor. The system shoubd be provision of Real time data display & downloding option,Wi-Fi/internet Computor connectivity, Cost of online UPS, Frame Fabrication & RCC foundation cost , Pole mounting acessories, installation charge online complete in all respect.(as per UPPWD approved make list) 170 Supply , installation of 5 zone central control unit (main frame) configured for 512 station, connection with EPABX & fire alarm system, 5 zone master control station,outdoor type ip 52 protection wall/column mounted station, weatherproof canopy,ip 65, 15w, horn type loud speaker, driver unit, station jb, loud speaker jb, desk top station, extension amplifier, cone type box,pdb with required incoming and out going feeder complete in all respect as per direction of E/I.(as per UPPWD approved make list) 171 Supply & Laying of 6 Core Signal & Loudspeaker Cable (Can be provided in 2 sets) and 3 core power cable in 50mm Dia HDPE Pipe. (as per UPPWD approved make list)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
45.
Agriculture #9455770 Technical Bid
Tender For Competitive E-Bidding For Fabrication Job Work For Bisalpur Kisan Sahkari Chini Mills ., Ltd., Bisalpur ( Pilibhit ) For The Season 2024-25 - 1 Description2 Pipeline work from 1/2 dia to 12 dia (M.S.)3 Dismantling of old street pipe line and dumping it in scrap yard4 Fitting/erection of new pipe5 Making new weld in the pipe line and fitting it in place6 Making new cross, tee, reducer, nipple in the pipe line7 Dismantling of valve8 Fitting of valve9 Cutting of old street flange and fitting new flange in place10 Opening of Magma Mascot Molasses Syrup Gas and Lime pipe lines, cleaning them and fitting them in place11 Cutting and removing street coils of different units and making and fitting new coils from the pipe12 Pipeline work of more than 12 dia (M.S.)13 Dismantling of old street pipe line and dumping it in scrap yard (dismantling)14 Fabricating of new pipe and putting it in place Erection15 Making and fitting new bend in the pipe line16 Making and fitting new cross, tee, reducer, nipple17 Dismantling the valve18 Fitting the valve19 Cutting the old flange and making and fitting new flange in place20 Cutting and removing the gully coil of different units and making and fitting new coil from the pipe21 Dismantling the round/square tank and placing it at the specified place and making a new tank as per the instructions with a new plate and making all connections as per the instructions and giving leak proof trial (size 1.00 m dia / less than 1.00 m dia)22 Cutting and removing the syrup line from the syrup sulphiter to the syrup tank, replacing the weak part and cleaning and re-installing it23 Dismantling the round/square tank and placing it at the specified place with 3/5/6 mm plate (size more than 1.00 m dia)24 Removing the round/square tank Fabrication of new 8/10/12 mm plate and fitting in place (erection & fitting) (size 1.00 m.25 Fabricate new throat manhole including flange and blind of various units and fit it with flange at the site (above 12 dia)26 Dismantling of light structure27 Fabricate and erect light structure28 Dismantle heavy structure29 Fabricate and erect heavy structure30 Strengthen heavy structure31 Construct platform at various stations as per instructions and install railings, stairs etc.32 Fabricate pump/motor duct as per requirement and fit it at the site33 Patch the throat area of ​​various round/square tanks/vapor pipe/body34 Fitting of throat brass tube of size 42 x 45 x 4000 mm / 42x45x2000 mm for quad, juice heater, vapor line juice heater and semiconductor Remove and expand by inserting tube and give trial after hydraulic testing. (Brass & S.S.)35 Remove all brass/S.S. tubes of pan and expand by inserting new tube and give trial after hydraulic testing.36 Dismantling the neck/damaged cone at any place and fabricating a new plate and fixing it at the original place. From 0.6 m. diameter to 1.00 m. diameter37 - Similarly - 1.00 m. diameter to 1.50 m. diameter38 - Similarly - 1.50 m. diameter to 2.00 m. diameter39 - Similarly - 2.00 m. Diameter more than40 Making and installing a new lane for involute casing blower upto 2 m. anywhere in the mill and giving leak proof trial and making all connections as per requirement and cutting and removing the old lane and putting it at the specified place41 Straightening the old plates taken out from various plants and making them ready for use42 Welding the lanes of various plants again and making them leak proof43 Making sheds including structure etc. for various D.V.44 Cutting and dismantling the damaged and rotten juice gutter anywhere in the mill and making and installing a new one as per instructions and giving successful trial45 Mill house work46 Cutting and removing the crooked and cut rails/square bars of can unloader and levelling the line by installing square bars and giving successful trial after strengthening it47 Cutting and removing the damaged and rotten runner of can carrier, secondary rack carrier and inter rack carrier and giving satisfactory trial by installing a new runner at the same place. 48 Hard facing on the runners of all rack carriers of the mill49 Cut out the neck and damaged runner base of can carrier, secondary rack carrier, inter rack carrier and replace it with a new runner base and give a satisfactory trial.50 For adjusting the chain of can carrier under can chopper can leveler, make a tightening arrangement under the can carrier and give a satisfactory trial.51 Cut out the lane and damaged side plate of can carrier and replace it with a new plate and give a satisfactory trial.52 Cut out the neck, side, top and discharge plate of fiberizer and replace it with a new 10/12 mm, MS plate as per the drawing and fit it and give a trial.53 Make and fit the side plate of mills pressure suit with a new 25/32 mm plate as per the drawing/sample and give a satisfactory trial. 54 Repairing the side plate/top/bottom plate of pressure suit by installing SS plate and replacing its broken teeth with new/repaired ones and giving a successful trial55 Repairing the static collar by installing SS plate and giving a successful trial56 Cutting the side plate of the pressure suit for static collar of mills and making a new one from 25/32 mm plate as per sample and removing the old SS plate and installing the new SS plate and welding it again in the side plate57 Cutting out the throat portion of bottom/side plate of rack carrier and secondary rack and taking it out and fabricating it with a new plate and giving a successful trial58 Repairing the damaged rack of rack carrier as per instructions59 Making new racks of all the rack carriers of mill 60 Cutting and removing the half round shoot from the neck of the rack carrier and making and installing a new one as per the instructions and aligning it61 Cutting and dismantling the neck and damaged juice tray of the mill and making and installing a new juice tray as per the instructions and giving a successful trial62 Cutting and repairing the neck portion of the juice tray and gutter fitted in the mill and welding them63 Making and installing a juice overflow box for juice maceration on the mill so that proper juice maceration takes place64 Making a half round of the roundness of the roller from 6 mm plate for covering the TRPF roller installed on the mill from below and joining it with the upper shoot and bolting it to the TRPF. Check by running and give satisfactory trial65 Make oil guard/tray below the mill in such a way that oiling in the pinion continues66 Make a new half round neck on top of mills chopper/leveler and fit it after welding67 Make a new taper box for juice extraction fitted on the side plate of mills pressure suit from outside68 Cut and remove the lane live steam line related to mill turbine and fit new saddle 40 line in its place and make all connections and give leak proof trial size 6/5/469 Dismantle both head stocks of mill no. 1 and place them at the specified place and fit the new head stock and align it and give satisfactory trial70 Boiler71 Cut and remove the lane and damaged side plate of bagasse carrier bagasse elevator and replace it with the provided plate72 Cut and remove the lane and damaged bottom plate of bagasse carrier bagasse elevator and replace it with new one Installing plate73 Renovating the bagasse chute falling from RBC to welt conveyor so that bagasse keeps sliding continuously and giving successful trial74 Renovating the bagasse silo blower fitted on the bagasse elevator, after balancing, installing it and giving successful trial75 Cutting and removing the screens of the bagasse silo which have melted, making and installing a new one as per sample/drawing and giving successful trial76 Cutting and removing the throat portion of 14 inch bagasse silo pipe, making and installing a new one as per sample/drawing and giving successful trial77 Installing half round chute as per instructions after boiler no. 1 at the rear end side of RBC and giving trial78 Boiler no. - Repair and correct sliding doors of boilers 1,2 and 3 and give satisfactory trial79 Cut and remove throat damper in flue gas ducting of boiler no. 1,2 and 3 and make and install a new one and give successful trial80 Cut and remove throat damper/valve in ID fan in flue gas line of boiler and install it in its place and give successful trial81 Boiler no. - Make new throat ducting before and after ID fan of 1,2 and 3 and install it in its place and give leakproof trial. 82 Remove the throat involute casing of ID fan of boiler no. 1 and 2 and place it at the specified place and make a new casing and install it in its place and give leakproof trial. 83 Cut and remove the throat ducting of FD/ID/SA fan and make and install a new one as per sample/drawing and give successful trial. 84 Make and install a new throat cone of ID fan of boiler. 85 Repair the throat box plate of air heater of boiler no. 1,2,3 as per instructions. 86 Cut and remove the throat ash shoot of boiler no. 3 and install it in its place. 87 Replace the throat and weak blowdown line and get it welded by IBR approved welder and install it in its place and give successful trial. Size 488 Cut and remove the gully waffle and throat structure of cyclone of wet scrubber and install new waffle in its place and give trial89 Cut and remove the gully/weak pipe line MS/SS of betascrubber and install new pipe and welding and give trial successfully90 Clean the chimney of boiler thoroughly and do two coat painting from inside and outside91 Renovate the bagasse suit falling from RBC/welt conveyor to bagasse yard so that bagasse keeps moving continuously and give trial successfully92 Cut and remove the gully air ducting going from FD in boiler no. 1, 2 and make new ducting with new plate and make it leak proof and give trial successfully93 Remove the gully mesh of ash pond along with frame and fit the given mesh and fit it with new frame94 Cut and remove the gully and damaged runner along with throat structure of bagasse elevator/bagasse carrier and install new one in its place Give satisfactory trial by installing runner95 Cut and remove the neck and damaged runner base (trough) of bagasse elevator/bagasse carrier and give satisfactory trial by installing new runner base (trough) in its place96 Boiling house (clarification house)97 Make necessary flange/blind for hydraulicizing vapour line juice heater and make it hydraulic and remove blind again and weld vapour pipe and give leak proof trial98 Replace weak cell, compartment plate, gully roof and recovery tower of juice sulphiter and give satisfactory trial99 Cut and remove gully partition plate of juice heater header and make it with new plate and install it in its place and give satisfactory trial100 Fabricate the gully cooler body of sulphur furnace by bending it with new 10/12 mm plate and give satisfactory trial101 Cut and remove the neck cell and cover plate of sulphur furnace, fit flange in new cell and make connections of air, steam, water and gas pipeline and Give satisfactory trial102 Repair the melted melters of sulphur furnace with new plates and give satisfactory hydraulic trial103 Dismantle the coolers of sulphur furnace and make new ones and install them and give successful trial104 Remove the entire body of sulphur furnace including cooler body, coil, flange, nipple etc. 105 Making the coil of cooler of sulphur furnace from new pipe and fitting it with flange and giving satisfactory trial.106 Making the melter and receiver of sulphur furnace from new plate and giving successful hydraulic trial.107 Removing the worn out coil of door/graver and making a new coil and installing it.108 Replacing the arm of door/graver.109 Cutting and removing the juice/mud box and dome from the neck of door/graver and fabricating a new one in its place and giving satisfactory trial.110 Replacing the internal tuff (tray) of door/graver and cutting and removing the old one and making a new one by installing a new plate/agil.111 Making and installing a new flash tank from the neck of door/graver and giving satisfactory trial.112 Replacing the mud tray of vacuum filter with 8 mm plate.113 Removing the vacuum filter agitator and installing a new agitator. 114 Dismantling the throat condenser of vacuum filter, fabricating it and fitting it in place and giving a leakproof trial.115 Fabricating the throat downtake of quad/vapor cell with the given plate and giving a satisfactory trial.116 Repairing the valve fitted on the quad and giving a satisfactory leakproof trial.117 Fabricating a new valve at the throat of quad/vapor cell and giving a satisfactory trial.118 Dismantling the external catcher of quad, fabricating it with a new plate and fitting it in place and giving a satisfactory trial.119 Cutting and removing the topcone of quadseval and fitting it in place after repairing the valve and giving a satisfactory trial.120 Cutting and removing the catcher of vapor pipe of semicondenser and making it with a new plate and giving a satisfactory trial.121 Dismantling of hollow plate of body of various units quad and fitting new 10/12 mm plate at its place and giving satisfactory trial.122 Fabricating and fitting new umbrella of vapor cell and giving satisfactory trial.123 Removing old mud separation plate (skirt) inside graver and making and fitting new one by bending it from 6/8 mm plate.124 Cutting and removing defective scroll of mud mixture and fabricating and fitting a new one and giving satisfactory trial.125 Boiling house (pan station)126 Replacing weak and hollow coil of pan and syrup sulphiter and giving leak proof trial.127 Fabricating and fitting new top cover of syrup sulphiter and giving trial. 128 Dismantling of the neck plate of the body of various units of pan and fitting a new 10/12 mm plate in its place and giving a satisfactory trial.129 Fabricating a new venturi of the condenser of the pans with S.S./M.S. as per the drawing/sample, fitting it and giving a satisfactory trial.130 Removing the neck wall of the pan and sending it to the scrap yard and fabricating a new plate and giving a leakproof trial.131 Repairing the wall on the pan and giving a satisfactory leakproof trial.132 Fabricating a new umbrella of the pan and fitting it and giving a satisfactory trial.133 Cutting and removing the neck taper part of the pan and putting it in the scrap yard and taping it with a 12 mm thick plate and welding it and strengthening it and giving satisfactory trial134 Dismantling of external catcher of pan, fabricating it with a new plate and fixing it in its original place and giving satisfactory trial135 Folding and fixing the steam jacket of pan with a 10 mm plate136 Patching the weak cell of pan / juice heater / quad calenderia with a 10 mm plate and giving leak proof trial137 Cutting and removing the neck catcher of vapour pipe of pan and putting it in the specified place and making a new one with a 12 mm plate and fixing it and giving leak proof trial after making all connections138 Cutting and removing the neck and weak vapour pipe of quad / pan and putting it in the specified place and making a new one with a 10 mm plate and fixing it and giving leak proof trial after making all connections139 Cutting and removing the neck body cell of 40/60 ton pan and putting it in the specified place and making a new one with a 10 mm plate and giving leak proof trial Make it as per drawing using 12/16 mm plate and fit it and give leak proof trial.140 Weld the leak welding of bottom cone of pan and calenderia by applying plate and give successful trial.141 Make leak gate valve of all crystallizers new and give leak proof/satisfactory trial.142 Repair the broken driving shaft of crystallizer and give it running after alignment etc.143 Make the cut bushes in crystallizer (warm wheel) leak proof and fix new warm/wheel and make it leak proof.144 Completely dismantle the 1350 C/F machine installed in the mill along with staging column and place it at the specified place and make and install the necessary staging column platform for installing new 1500 C/F machine. 145 Repairing the gully cooling shaft of air cooled crystallizer and cutting and removing the gully coil and blinding it at the said place and fitting an arm in the shaft for air cooling, removing the drive for the said work and fitting it in place and giving a satisfactory trial.146 Boiling House (Centrifugal Station)147 Removing the gully/damaged discharge chute of centrifugal machines and fabricating a new chute and fitting it in place and giving a satisfactory trial.148 Cutting and removing the gully tray of the hopper and fabricating a new tray with a 3/4 mm plate and preparing and fitting a cleat with an angle of 75 mm and fitting the new tray in place and giving a satisfactory trial.149 Cutting and removing the gully/damaged driving portion of the hopper and riveting it to a new 10/12 mm plate and fitting it in place and giving a satisfactory trial.150 Removing the gully air valves of the hopper and repairing it as required and making and fitting it with a new plate and giving a satisfactory trial.151 Dismantling the throat base frame of sugar hopper and making a new one and giving it a successful trial152 Dismantling crystallizer no. 10 and putting it in the scrapyard and replacing it with crystallizer installed for C-1 in the mill and giving it a successful trial153 Cutting and removing the throat and leaking coils of vertical crystallizer and installing new coils at the said place and giving a satisfactory hydraulic trial154 Welding the throat arm of vertical crystallizer and fitting it with a new pipe and giving a hydraulic trial155 Cutting and removing the throat jacket of twin vertical crystallizer and placing it at the specified place and making and fitting a new one and giving a leak proof trial156 Removing the defective paddle of magma/pugmill and making and fitting a new one157 Dismantling the soft of magma mixture and making and fitting a new one and giving it a successful trial158 Removing the throat/defective body of mud mixture/pugmill/magma mixture and fitting it with a new plate Fabricate and fit new ones in place and give trial159 Remove defective clusters of spray pond and fit new ones160 Make and fit new cover of SC-1100 / SC1350 KT centrifugal machine161 Open and clean the choke of spray pond and fit all nozzles in place and also fit new or old nozzles162 Cut and remove the throat pipe of pipe/header/section above 12 dia of spray/injection and fabricate and fit new ones in place163 Make new gasket and footwall mesh of injection/injection pump MF 40/40164 - Tadav -8 UP-2/10 UP-1 mesh165 Make new and fit steam coil in syrup/molasses/massification tank166 Fit new vertical injection pump at the specified place and make connections with valve in injection header as per requirement and cut/make tin shed as per requirement successfully Conducting trial167 Making necessary staging, column, platform for new sugar grader and installing new sugar grader168 Replacing weak arm of air cooled crystallizer169 Cutting and removing tail pipe of pan/quad and fitting new tail pipe170 Cutting and removing mini condenser on pan and making and fitting new mini condenser in place171 Cutting and removing caladria of pan no. 7 and fitting new caladria and making all connections and giving leak proof trial.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttar Pradesh View Result →
46.
Power #9355489 Technical Bid
Design, Engineering, Manufacture, Survey, Supply, Transportation, Erection, Testing & Commissioning of 1x6.3 MVA, 33/11KV Receiving Station including 33 KV Line at GMC Associate Hospital Rajouri on Turnkey Basis.” under the jurisdiction of Executive Engineer, Sub Transmission Division KALAKOTE, JPDCL Jammu- 1 33 KV LINE BAY OF SINGLE BUS SCHEME (2 Nos); (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 2 SITC OF SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type)with allied accessories and heavy duty pad clamps. 4 33kV C&R Panel along withO/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port 5 33 kV Isolator With Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 6 33 kV Isolator Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 7 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 8 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) 9 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 10 33 kV Polymer Post Insulator36kV,170kV Impulse, creepage distance 1224m 11 SITC OF GI STEEL STRUCTURES 12 Nominal Bore 200, 5.9 mm Thick 13 Galvanised Steel Structures 14 Galvanised Nuts & Bolts 15 SITC OF CONTROL CABLES 16 Supply, Laying, Testing & Commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 17 Supply, Laying, Testing & Commissioning of 04Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 18 Supply, Laying, Testing & Commissioning of 02 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS as per relevant Standards 19 Lugs, Ferrules etc. 20 SITC OF CONDUCTOR & HARDWARE 21 Providing & Fixing 200 mm² ACSR Conductor Panther 22 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 23 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 24 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 25 GI Earth wire 7/4.00 mm sq. 26 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 27 COST FOR 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 28 SITC OF SUB‐STATION MAIN EQUIPMENT 29 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 30 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 31 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 32 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 33 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 34 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 35 SITC OF GI STEEL STRUCTURES 36 Nominal Bore 200, 5.9 mm Thick 37 Galvanised Steel Structures 38 Galvanised Nuts & Bolts 39 SITC OF CONTROL CABLES 40 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 41 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 42 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 43 Lugs, Ferrules etc. 44 SITC OF CONDUCTOR & HARDWARE 45 Providing & Fixing 200 mm² ACSR Conductor Panther 46 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 47 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 48 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 49 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 50 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 51 SITC of 6.3 MVA 33/11KV Power Transformer; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 52 6.3MVA 33/11kV, ONAN, Copper wound, Out-door Type, conventional Power Transformer, Oil Filled with OLTC and all accessories including HT and LT Terminal connections and Tertiary Winding. 53 Providing & Fixing of Al Bus bars for transformer terminals of suitable size with color coding, heat shrinkable sleeves covered including drilling, welding etc as per requirement to be fixed on LV side of transformer as per relevant Standards 54 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 55 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 56 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 57 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 58 COST FOR 11 kV INDOOR SWITCHGEAR OF 6.3MVA, 33/11 KV SUBSTATION; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 59 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+4)SET 60 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 61 11 kV3- Core XLPE 400 mm² armoured, FRLS 62 11 kV3-Core XLPE 120 mm² armoured, FRLS 63 11 kV Indoor Heat Shrinkable Cable Termination Kits 64 11 kV Outdoor Heat Shrinkable Cable Termination Kits 65 11 kV Indoor Heat Shrinkable Cable Termination Kits 66 11 kV Outdoor Heat Shrinkable Cable Termination Kits 67 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 68 11 Mtr. Long Pole (ST-410 SP56) 69 9 Mtr. Long Pole(ST-410 SP33) 70 33kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 71 33kV HGF Set 3-Phase, 3-Pole, 200 Amp 72 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 73 Galvanisedironof sorts including CH Angle brases Clamps etc. 74 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Copper wound) (1No. Spare) 75 120 mm²PVCLT Cable 4 Core, armoured, FRLS 76 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 77 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of size 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 78 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 79 11kV Bus Bar Fuse Set Out Door type for Auxilary Transformer 80 COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 81 Compound wall of Receiving Station By way of mass concreting in foundations and 228mm brick wall of 2 m height including main gate and allied works 82 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 83 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 84 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 85 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 86 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 87 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 88 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 89 Borewell 125mm dia and 100mtr in depth with 2HP Submersible Pump including distribution complete job. 90 BUILDING: A. Control Room Building on ground floorcomplete with Column and Beam structures with 1 no J.E. Room , 1 Store room, 1 Battery Room and a main hall including a luminium windows, cable ducts for power and control cable, Toilet (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and o ther fixtures) 2 coat of putty with Priming coat and Reputed Colour of 2 coats to the entire building as per the direction of concerned engineer , painting of doors and windows etc. Overhead water Storage tanks . Water Supply . Septic Tank complete with Sanitary Fittings including kota stone floor. including RCC slab in furnished conditioncomplete in all respects.(Note: The Contractor shall submit the building drawing in all respects i.e. structural / architectural prepared by authorized Architect for approval from the dept for execution of works.) 91 BUILDING:B. Staff Quarters on 1st floor with Column and Beam structures includingToilets (completewith WC, Washbasin and fittings), electric fittings(fans, LEDtubelights, leds powerpoints and other fixtures of reputed make) Putty of 2 coats , Priming 2 coatsand reputed colour as directed by concerned Engineer to the entire buildingComplete in all respect painting of doors and windows etc. Overhead water Storage tanks . Pantry Room with all the Fittings. Water Supply . including Tile and marble flooring with periphet and Stairs Complete, two room complete with beding chair etc. as per the direction of engineer incharge.(Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechuralprepared by authorised Architect for approval from the dept for execution of works.) 92 Development of land by removing weeds, wild grass and endulation if any, ornamental land scaping and growing of ornamental trees in unbuilt areas/road sides and Construction of approach path by Way of Cement concreteing/ Interlocking tiles/blacktopping including drains complete. 93 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 94 COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATIONS; (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 95 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 96 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 97 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 98 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 99 Providing of Rubber Mat 1mx2m 19mm thick 100 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 101 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 102 Providing of Industrial safety Helmet 103 Providing of Rubber Gloves for 33 kV level 104 Providing of Rubber Gloves for 11kV level 105 Providing of Industrial Safety Belt with comfort foam reinforment 106 Providing of Safety volcanized rubber Shoes 107 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 108 Providing of HV Detectors all voltages with fibre rod 109 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 110 Providing of Forged Adjustable wrench of 22mm and 32mm size 111 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 112 Providing of Nose Plier 113 Providing of Normal Plier 114 Providing of Sledge hammer of 2Kg with handle 115 Providing of forged Chisel long shank type 116 Providing of HSS Cabron steel Hack saw with frame and set of 6 blade withtwo sided teeths 117 Providing of Measuring tape of 12 feet spring loaded 118 Providing of Precise 1 feet long bubble based water level 119 Providing of 600 watt hand drill with drill bits of HSS Hammer type 120 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feetdimensions with different chambers 121 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 122 Providing of Screw driver tester neon lamp based 123 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 124 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 125 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 126 Providing of foldable multi-purpose aluminium ladder 127 Office Steel Chairs wih Armrest 128 Office Table of Standard Size with Sufficient Drawers 129 Office Almirah With Locker of reputed make 130 Cost of Installation of Capacitor Bank (INCLUDING ALL CIVIL WORKS& EARTHING OF EQUIPMENTS AS DIRECTED BY THE ENGINEER INCHARGE) 131 11 KV Capacitor bank 2.4MVAR with VCB Panel with complete arrangement for connection with 11 KV incomer panel, Series Reactor, Isolator, RVT, Surge Arrestor, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with Structure, foundation and accessories. 132 SITC OF 33 KV LINE 133 11 Mtr. Long Pole (ST-410- SP56) 134 GI V cross-arm with top Bracket including clamps 135 GI Channel X-Arm including clamps and braces 136 GI Wire SSS 137 100 mm² AL59 Aluminium Claded Steel Conductor 138 PG Clamps for 100mm² ACSR Conductor 139 Tension Clamps with bail & IPC (Insulation Piercing Conductors) 140 Alignment Ties 141 IPC (Insulation Piercing Conductors) from bare to CC (Covered Conductor) 142 IPC from CC to CC Connection 143 IPC with Aluminium bail for Earthing 144 Mid Span Joint 145 33 kV Isolator without Earthing Blade (36kV, 2500A, Outdoor, 3 poles, 25 kA) 146 33kV Polymeric composite Pin Insulator 36kV, 10kN,Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm 147 33kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting 148 Galvanized Nuts and Bolts. 149 Danger Plates with Clamps 150 Anti-Climbing Device with Clamps 151 Earthing Complete by GI Pipe 40 mm or GI Rod20mm, 3 mtr long through GI Strip. 152 Red Oxide 153 Aluminium Paint 154 Cement bottoming for 11 Mtr Long ST Pole, 0.78 Cum/Pole 155 Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete 156 SITC OF 11 kV LINE 157 8 Mtr. Long Pole( ST-410 SP15) 158 GI V cross-arm with top Bracket including clamp 159 GI Channel X-arm including clamps and braces 160 50 mm² ACSR Conductor 161 PG Clamps for 50 mm² ACSR Conductor 162 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 163 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 164 Galvinized Nuts and Bolts 165 Danger Plates with Clamps 166 Anti-Climbing Device with Clamps 167 Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. 168 Red Oxide 169 Aluminium Paint 170 Cement bottoming 1:2:4 mix as per REC standards .45cum /pole 171 Aluminium Jointing Sleeves 172 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Jammu And Kashmir View Result →
47.
Defence #9353987 Technical Bid
Tender For Provision Of Work Services For Solar Power Plant At Af Stn Adampur; 1 SCHEDULE `A PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 2 Construction of SUB STATION BLDGcomplete all as specified and shown on drawings. 3 NOTE: Schedule ‘A’ Part IIto X under Ser No. 2.01to 2.10 are Prepriced by MES. 4 Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 5 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION as listed in Schedule ‘A’Part III 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 7 Lump sum price worked out by the Contractor for “SOLAR POWER PLANT” as listed in Schedule ‘A’Part V 8 Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT” as listed in Schedule ‘A’Part VI 9 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’Part VII 10 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’Part VIII 11 Lump sum price worked out by the Contractor for“SEWAGE DISPOSAL ” as listed in Schedule ‘A’PartI IX 12 Lump sum price worked out by the Contractor for“AREA DRAINAGE” as listed in Schedule ‘A’Part X 13 Lump sum price worked out by the Contractor for“FENCING AND GATE” as listed in Schedule ‘A’Part XI 14 SCHEDULE `A PART - XII MISC ITEMSis not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. 15 INTERNAL ELECTRIFICATION 16 S&F LED light fitting 1 x 10 Watt, 220V, AC,box type with driver, holder incl making connection with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed. 17 S&F LED security light fitting 20 watt, input 110 to 220 voltsas per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed. 18 SOLAR POWER PLANT 19 Design, supply, erecting, installation, testing & commisssioning of ON Grid connected, ground mounted solar PV Plant of 737 KWp capacity at standard condition (irradience temp etc) at AF Stn Adampur (Longitude 75° 44 20 E, Lattitude 31° 26 14 N & elevation 244.54 mtr). The ripple content shall not exceed 3% on DC and harmonics shall not be more than 3%, Micro processor based directional & revese power flow protection shall be provided to ensure isolation of SPV from Grid at the time of fault including all connected equipments required for their smooth functioning comprising of the following major componenets all as specified:- 20 Supply, erecting, installation, testing & commissioning of framed dual glass bifacial Solar modules each consist of 144 cells (12x6+12x6), size of module 2278mm (L) x 1134mm (W) x 33mm (T) or as approved, M10 TOPCon N type mono bifacial solar cells not less than 585 Wpeach, front glass 2mm low iron printed semi tempered glass, back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate, IP68 weatherproof PPO junction box, compatible with IP68 rated MC4 connector alogwith 1400mm DC, Copper cable of 4sqmm size, anodized aluminium framehaving efficieny more than 22.5% at standard test condition. These panels shall be suitably fixed on Module mounting structure. The electrical Data of panel at standard test condition (STC) 1000W/m² irradiance, air mass 1.5 & 25°C cell temperature shall be as under:-(i) DC peak power (Pmax) - not less than 585 Wp. (ii) DC peak voltage (Vmp) - 44.15V (Approximate). (iii) DC peak current (Imp) - 13.25A (Approximate), (iv) Short circuit Current - 13.99A (Approximate). (v) Open circuit Voltage - 52.70V (Approximate). (vi) Module efficiency - 22.65% (Approximate). (vii) Operating temp range (-) 40°C to 85°C. (viii) Series fuse rating = 30A (Approximate). (ix) Junction box = IP68, weatherproof PPO. (x) IP68 rated MC4 connector compatiable. (xi) Anodised aluminium frame. (xii) front glass 2mm low iron printed semi tempered glass. (xiii) back glass 2mm low iron printed semi tempered glass, PID free & UV resistant encapsulate. (xiv) Sustain heavy snow upto 5400 Pa. (xv) Sustain wind loads upto 2400 Pa. 21 Note :-(a) The PV modules must be tested and approved by one of the IEC authorised test centers. In addn a PV module qualifacation test certificate as per IEC standard, issued by ETDC Bangalore or Solar Energy Centre will also be valid. (b) Warranty on output and life of structure shall be as under :-(i) Output wattage of PV modules shall not be less than 90% at the end of 10 years and 80% at the end of 25 years.(ii) The mechanical structure, electrical works and overall workmanship of the grid solar power plant must be warranted for a minimum of 5 years.(iii) Grid solar PV power plant must install necessary equipment to measure solar radiation, ambient temperature, solar energy meter 11 KV to measure grid solar power generation, wind speed and other weather parameters contnuously. Simullataneuosly measurement of the generation of DC power as well as AC power from the plant must be done. 22 (c) Each module shall have RFID tag bearing the following details. RFID reader shall be provided by contractor :-(i) Name of manufacturer of PV module (Should be made in INDIA). (ii) Name of manufacturer of solar cell (Should be made in INDIA). (iii) Month and year of manufacture (Separately for cell & module). (iv) Country of origin separetly for cell & module (Made in INDIA only). (v) Peak Wattage, Im, Vm and fill factor of the module. (vi) Date of year of obtaining IEC PV module, qualification, certificate. (vii) Unique serial no and model no. of Module. (viii) I-V curve of module. (ix) Name of the test Lab issuing IEC certificate. (x) Every module should have PID test report as per latest prevalling norms of MNRE & will be submitted to the GE. (xi) Solar cells & Modules shall meet DCR norms. 23 (d) Provision of earthing and earth strip/cables etc. for earth for solar PV module/Array as per latest IS/MNRE norms to be providied it will be measured and paid seperatly. (e) PV module shall confirm to IEC:61215, IEC: 61730, UL:61730-1 & 2 for construction, testing and safety qualifacation and latest minimum technical specifications. The module shall be manufactured in 2024 or subsquent year. Product warranty shall be for at least 12 years and performance warranty shall be at least 25 years. 24 (f) The contractor will submit the complete design of ON Grid connected Solar PV Plant alongwith complete design details, drawings, calculation sheet and connected documents within one month of acceptance of tender and before procurement of the material. The same shall be submitted to GE after vetting from IITs/NISE for approval of accepting officer. (i) The complete design will submitted to Accepting Officer through CWE for final approval before placing order of the materials to be used in Solar PV Plant. (ii) The test report of modules as per national and international standards and technical data shall be submitted by contractor to GE for approval of accepting officer. (iii) Minimum 0.5% of PV Module shall be tested for all electrical parameters incl efficieny & safety measure by the rep of AO at OEM factory premises before dispatch as per technical data sheet of the manufacturer. (iv) Contractor will submit 2% amount of total quoted amount against item Sl No 4.04 (PV Module) as performance security of PV Module in the form of FDR or BGR in favour of the Accepting Officer which will be refurned to the contractor on successful performance copletion of 25 years of PV Module.(v) Contractor will submit gurantee for at least 25 years performance of PV Module as per CA provision and in case of any manufacturing fault of any PV Module during the performance warranty of 25 years the same shall be replaced by the contractor without any extra cost. (vi) All the modules shall be of same make. (vii) Rates of testing at Factory premises of OEM or MNRE approved Lab are deemed to be included in the quoted rates.(g) Make : MNRE approved and as per list of makes mentioned in Appx D of the tender documents. 25 (viii) The solar power plant shall be got tested/ inspected by third party i.e. NISE or any other Govt approved lab as decided by Accepting officer. Cost of testing and all other arrangement for this shall be made by the contractor without any extra cost.Third party inspection/ testing shall be carried out after execution of complete work and all departmental testing. (ix) Acceptance/ Final test from rep of Accepting Officer shall be carried out after physical completion of solar power plant work.All arragement for this shall be made by the contractor without any extra cost. (x) The following tests shall be carried out: (i) Performance ratio test (ii) CUF (iii) Efficiency test (iv) Irradiance test (xi) All drawings and design duly supported with detail calculation and property of the equipment shall be submitted by the contractor within two months from the date of issue of work order for approval of the Accepting officer. 26 Design, supply, installation, testing & commissioning String PV Inverter of capacity not less than 250 KW. Input DC & output AC specification of the inverter shall be as under :-Input DC. Max input DC voltage not less than-1500V, rated input voltage not less than 1080V, start up voltage 550V, minimum MPPT voltage range 180-1500V DC, MPPT voltage range at full load 800-1300V DC, minimum number of string input 24, minimum number of MPP trackers-12, string per MPPT- 2 Nos, max input current per MPPT shall not be less than 30A, max short circuit current per MPPT shall not be less than 50A. 27 Output AC.Minimum AC output power 250 KVA@30°C, 235KVA @40°C, 220 KVA @ 50°C, max output current not less than 184A, Nominal 3 phase voltage- 800V, minimum Grid voltage range 640-920V, Frequency- 50/60Hz, Grid frequency range - 45~55Hz, Active power adjustment range- 0-100%, THDi- <3%, power factor 0.8 leading-0.8 lagging, 3 phase.Performance.Max efficiency - not less than 99.01%, European weighted efficiency - not less than 98.8%, outdoor string solar power grid tie inverter suitable to convert DC power of solar PV module/array to AC for further feeding to grid & conforming to IEC-61683 for efficiency, IEC-62109 (1&2) or equivalent for safety & IEC-62093 for reliabilty. The inverter shall be self-communicated with pulse width modulation (PWM) technology and shall be capable to synchronize with grid maximum in 1 minute. Maximum Power point tracker (MPPT) conforming to IEC-62093 shall be intergrated in the inverter to maximize energy drawn from the solar PV array. 28 The inverter shall have following protections:- (i) DC reverse polarity protection. (ii) Anti Islanding protection. (iii) Leakage current protection. (iv) Ground fault monitoring. (v) PV array string fault monitoring. (vi) Zero voltage ride through. (vii) DC switch. (viii) Anti PID protection. (ix) AFCI protection (Arc Fault Circuit Interrupter). (x) Over voltage. (xi) Under voltage. (xii) Overload. (xiii) Shorcircuit. (xiv) Earth fault. (xv) Under frequency and over frequency.Protection class/Overvoltage category- I/III. Input/output SPD- PV type-II & AC type-II standard. Electromagnetic compatibility (EMC) as per EN-61000-6-2&4. Safety standard as per IEC62109-1/2, IEC62116, IEC61727, IEC61683, IEC60068(1,214,30). Communication- RS485, USB, Bluetooth, Wi-fi, GPRS, PLC.Inverter shall monitor the following:-(i) DC input voltage (ii) DC input current (iii) DC ripple (iv) DC input power (v) AC output (vi) AC output current (vii) AC output power (viii) AC output frequency (ix) AC output power factor (x) Synchronization status (xi) Grid voltage (xii) Grid frequency (xiii) Grid (ii) Ground fault (iii) PV string fault montioning inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. 29 General specification:- (i) Ambient temperature range - (-) 30°C to (+) 60°C. (ii) Self consumtion power at night - < 2W, Topology- Transformerless. (iii) Degree of protection - IP66. (iv) Allowable relative humidity 0-100%, max operating altitude - not less than 4000M, (v) Noise - <60Db. (vi)Cooling - Smart forced air cooling. (vii) Display - LCD & Bluetooth+App.Rate for PCC foundation including required concreting and steel fixing as instruction and directed by engineer-in-charge are deemed to be included in quoted rates.Isolation method tranformer less smart forced cooling LED display, Rs 485/PLC communication, smart IV Curve Diagnosis, Type II SPD for both DC & AC with 5 years guarantee. Make: HITACHI/Delta/Sungrow.Note:- (i) Contractor shall submit parameter sheet of inverter duly recommended by GE & CWE for approval of AO before placing order to the company. (ii) All the inverter shall be of the same make & model. 30 MC4 CONNECTORSSupply, installation, testing & commissioning of solar MC4 connectors (Male and female both) having copper pin with tin plating with 1500 V DC & not less than 30 Amp. Current suitable for 4/6 sqmm cable, degree of protection IP-68, contact resistance < 2 mili ohm, insulation resistance >500 Mega ohm, insulation material PPO, protection class-II, application class A, standard EN 50521: 2008 TUV certified and shall also meet the requirement of IEC:61984 complete all as specified and directed. Make: Indygreen/Elmax/synergy/Eteilyte Technologies India Pvt Ltd . 31 Modules Mounting Structure (MMS) Design, supply and erect Module mounting structure made up of MS Hot dip Galvanised (80 Micron) as per IS 4759, GI frame Structure to hold approved solar panels mounting with all accessories.Fixing arrangements for fixing the PV solar modules & to withstand minimum horizontal wind speed of 170 km/ hr as per IS. It shall conforming to latest revesion of IS 2062 having Grade of 250 MPA. The MMS design shall be submitted by the contractor and shall be approved by AO. The solar panel shall be fixed at a tilt angle of 31° or as per designed SPV Plant. Note : The design should be similar as per drawing attached. 32 Mounting Structure shall have following specification:-(i) Nut, bolts and supporting structure including module mouting structure shall have to be adequately protected from atmosphere and weather prevalling in the Adampur Air Force Station. All fastners shall be of stainless steel of Grade SS 304.(ii) Two numbers of anti-theft fastners of stainless steel on two diagonally opposite comer of each module shall be provided.(iii) The rep of AO, shall visit the factory site of galvanising for each section of lot of dispatch to collect the samples at random & send the sample duly sealed & signed by him and rep of contractor to nearest NABL accredited Lab for testing. The lot will bedispatched from factory permises only after passing of sample from Lab. In case of failure of sample complete lot will be rejected. The quoted rates are deemed to include these provisions. 33 Note:- (i) cost of interconnecting copper cables along with cable trays (floors/ wall mounted) suitable to accommodate solar grade cables & cables upto invertersshall be measured and paid separately under relevant items. (ii) Earth work and foundation of MMS shall be measured and paid separately under relavent items (iii) MM structure shall be paid as per actual size installed st site. 34 M&L for tinned copper conductor, 6 Sqmm XLPO insulated and sheathed, UV-stabilized, single core multi-stranded DC cables- RED & BLACK (FOR PANEL INTER CONNECTION), complete as all specified below and directed.(1) Construction(i) tinned copper conductor IEC 60228, class-S(ii) Insulation/sheath:- electon beam cross linked halogen free & flame retardant compound (XLPO)(2) Electrical(i) Voltage Test: 6500V as per EN 50395 (ii) Max permissible operating Volatge:- DC 1.5 KV (conductor-conductor, non earthed system)(iii) Nominal Voltage :- AC 0.6/1.1 KV & DC -900/1.5 KV(3) Temperature(i) Amblent temp: (-) 40°C to (+) 90°C (ii) Max conductor temp (-) 40°C to (+) 120°C(4) Strandards & Material properties(i) Fire performance -IEC 60332-1-2(ii) Smoke emission:- IEC 610374/EN 50268-2(iii) Approval :- EN 50618, HIZ272-KMake: Polycab/Havells/Finolex/KEI India/RR KabelNote: (i) Routine testing of cable shall be carried out by rep of AO at the factory premises of OEM, before dispatch. 35 Supply and laying in trenches, 3.3 KV underground cable, XLPE insulated armoured heavy duty electric cable with aluminium conductor 3300 Volts grade, cross sectional area 300 Sqmm, 3.0 core multistranded, confirming to IS-7098 (Part-1):1988 suitable for earthed system including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall complete all as directed by Eng-in-Charge. (ACDB to LT Panel and LT Panel totransformer). 36 All same as per item No 4.17 above but size of 120 Sqmm 3.0 core (Busbar No 1 to ACDB No 1, Busbar No 2 to ACDB No 2 and Busbar No 3 to ACDB No 3) 37 M&L for 70 Sqmm 3.0 core, 1100 volts grade PVC Copper Cable flexible, conforming to IS 7098 (Part-2):1988 (Inverter No 1 to Busbar No 1, Inverter No 2 to Busbar No 2 and Inverter No 3 to Busbar No 3) complete all as specified and directed by Engr-in-Charge. 38 HT TRANSFORMER (INVERTER DUTY FOR SPV PLANT)Supply, installation, testing & commissioning of copper wound, step up cum inverter duty conforming to IS:2026 or latest IS standard, HT Transformer, outdoor type capacity not less than 1000 KVA, 0.800/11KV, 50 Hz, Dyn 11, ONAN class A for solar application, Star Delta Tapping + 7.5 % to -7.5% @ the step of 2.5% ON load type tap changer, with first filling of transformer oil as per IS:355, ISI marked , duly filtered & Dehydrated and other standard fitting/ accessories including Platform & foundation for Transformer installation as recommended by manufacturer. The total losses (No load + Full load) at 75 deg C shall not be more than 1% of rated capacity of transformer, Impendence 5%. The following are included:-(i) Name, rating & diagram plate. (ii) Tap changing switch. (iii) Earthng terminals. (iv) Lifting lugs. (v) Oil level indicator 150 mm dia with alarm & trip contact. (vi) Oil drain valve with plug (vii) Oil filter valve with plug. (viii) Conservator with oil filling hole with cap. 39 (ix) Thermometer pocket. (x) 4 Dial type thermometer stem type & with MRP. (xi) Air release plug. (xii) Silicagel breather. (xiii) Removable inspection opening on top cover. (xiv) Explosion vent. (xv) Bi-directional CI rollers. (xvi) Arching horn set. (xvii) Winding temperature indicator with alarm & trip contact. (iii) Marshalling box for 03 Nos. (iv) Magnetic oil level gaugue (v) Pressure release valve (PRV) with trip contact. (xviii) Conservator with oil filling hole with cap & drain plug and with bulit in diaphragm to avoid direct air contact with transformer oil. (xix) Oil level indicator with minimum level marking. (xx) HV cable box (xiv) LV cable box (xv) Bucholz relay with control connection upto HT VCB including testing at OEM premises.Note : Cost of PCC foundation as per OEM foundation drawing & necessary earth work (excavation, returning filling & making good to surface) shall be deemed to be included in quoted rate.Make:- GEC (Prolec)/ABB/Siemens/Schneider/ITE Gurgaon/CG Power & solution Ltd. 40 M&L for 50 Sqmm single core, 0.6/1.1 KV PVC insulated and PVC sheathed Copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 41 M&L for 6 sq.mm single core, PVC insulated and PVC sheathed copper flexible cable, IS :7098 complete as all specified and direcetd. (LA Top to Earth strip of pit) 42 M&L for 1 sq.mm , 2 core, RS 485 cable twisted shielded unarmoured copper cable complete as all specified and directed (Data Monitoring Cable for communication) 43 ACDB Panel for 750 KWp Inverters (3x250 KW inverters) Design, supply, installation, testing & commissioning of outdoor type, floor mounted ACDB Panel for 750 KW Inverters having 3 incoming & 1 outgoing, IP-65 protection rating with PCC foundation for civil works (Excavation, cutting, Grouting, PCC etc) Fabrication with 3.15 mm thick CRCA sheet steel, 7 tank power coated, floor mounted panel with 40x40x6mmMS angle stand, cable entry from bottom through gland plates, internal control wiring with suitable size copper cables, cable alley, three numbers 1200 Amps aluminium bus bar EC grade incld heat shrinkable PVC sleeves complete all as specified and directed and having following switchgears :- 44 OUTGOING:-1 No.800 Amp, 3 Pole,50Hz, 3 phase, ACB Drawout type, motorised charging, with microprocessor release, Icu = Ics = Icw 50 KA,suitable for 800 volt, 3 phase, 50 Hz with ACB spreader Link with R,Y,B LED indicating light, digital Multimeter 800 volts CL-1, 3 Nos Metering CT 800/5A TP SPD Type 1+2 40 KA. INCOMING :-3 x 250 Amp, Icu = Ics = 36 KA 3 pole MCCB microprocessr released with spreader links. The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01(b) Ammeter with selecter switch -01(c) Frequency meter - 01(d) R,Y, BIndication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three.(f) CT 800A/5A, CL-0.2, 5VA- Set of three(g) Auxiliary transformer 50 VA, 800V/230V - 01 NoNote:- Contractor shall submit drg of ACDB panel to GE for approval of accepting officer before procurement. 45 LT Panel for 750 KWp inverters Design, supply, installation, testing & commisssioning of outdoor type, floor mounted LT panel of 3.15mm thcik CRCA sheet steel powder coated for 750 KWp inverters having 1-input & 1- output, IP-65 rating, cable alley with PCC foundation for civil works (excavation, cutting, grouting, PCC etc) TP SPD,type 1+2 40 KA, MCCB extended ROHM, all cable entry from bottom through gland plates, 3 Nos control fuse 16A with base for SPD,three 1200 Amps Aluminium bus bars Ec grade incl heat, shrinkable PVC sleeves, Aluminium busbar links, internal wiring with suitable size copper cables, with 40x40x6mm MS angle stand , 7 tank powder coated, three 6A SP 10KA MCB C Curve etc complete all as shown on drawingscomplete all as specified and directed. 46 INCOMING:-1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links.OUTGOING1 No of 800 Amp 3 pole ACB, Icu = Ics = Icw = 50 KA- 800 Volts, drawout type, motorised charging, with microprocessor release ACB/MCCB Spreader links:- The panel should contains follwoing metering devices :(a) Volt meter with selecter switch -01 No(b) Ammeter with selecter switch -01 No(c) Frequency meter - 01 No(d) R,Y, B Indication Lamp LED type- 01 Set of three.(e) PT 800V/110V,-01 Set of three (f) CT 800/5A, CL -0.2 , 5VA - Set of three(g) Auxiliary transformer 50 VA, 800V/230V -01 No.Note:- Contractor shall submit drg of Panel to GE for approval of accepting officer before procurement. 47 COPPER BUSBAR CHAMBERM&L for outdoor type, floor mounted , vermin proof, totally enclosed bus bar chamber of not less than size 800 mm (H) x 800mm (W) x 600 (D) made out of 3.15 mm thick CRCA sheet , incl three number 300 Amps pure copper busbar having size of 200 MM (w) x 100 MM (thick), 0.5 Mtr length/ phase incld heat shrinkable PVC sleeves, duly supported on insulators, it shall be IP-65 rated. Cable entry from bottom and suitable for input of 70 sqmm, 1.1 KV copper cable and output of 120 sqmm, 1.1 KV XLPE cable, powder coated complete all cable entry from bottom through gland plates all as spceified and directed. 48 MONITORING SYSTEMDesign, Supply, installation, testing & commissioning of monitoring system to monitor the performance of the PV Module & inverter (Power arrray voltage, array current & AC parameters), energy yield temperature, irradiance level, humidity, Air Mass, wind velocity etc, and it could provide flexible interface to facilities PC based inverter monitioing and control via GPRS modem and internet/ethenet connection. This should have include web visulization system and data logger with integrated ethernet port. The monitoring system shall be comprises of following :-(a) 5G based plug and play RTU with smart data logger to connect inverters & sensors - 1 Set. (i) Modbus RS485 RTU. (ii) 2 Analog ports. (iii) Built in memory help store and send data in case of network failure. 49 (b) IP-67 Enclosure box (280mmx190mmx130mm) or as approved with SMPS power supply and other accessories to house the RTU - 01 No.(c) Access to web portal-server charges for 1 years data frequency 10 minutes.(i) Interractive Dashboard. (ii) Single line diagram. (iii) PR analysis. (iv) Solar radiation & weather data. (v) Graphics and reports. (vi) Generation analysis. (vii) Log reporting. (viii) String/MPPT monitoring. (ix) Plant/Inverter performance. (x) Superuser dashboard for centralized monitoring. (xi) Mobile app on android. (d) Weather sensors.(i) Solar radiation sensor with mounting kit - 01 No. (ii) Wind speed sensor with mounting kit - 01 No. (iii) Ambient temperature sensor with mounting kit - 01 No. (iv) Module temperature sensor with mounting kit - 01 No to be provided complete with readouts integrated with the data logging system. 50 (v) Analog to modbus module - 01 No. (vi) Wind direction sensor with mounting kit - 01 No.(e)All in one Desktop computer, 12 th Gen intel core i3, 21.5 inch monitor screen, FHD display, 8 GB RAM, 512 GB SSD with Window 11 including wireless keyboard and mouse complete. Make : HP / Dell/ Lenovo / Microsoft(f)Laser Jet Printer, print speed not less than 18 ppm, power consumption not more than 320 watt, capable to print on A4, A5, B5 & legal size paper, single function including power cable & USBcable, toner, installation CD and user manual complete. Make : HP / Canon/ Xerox 51 Note : The following information shall be displayed in the monitoring system:-(i) Individual module power generation, voltage, current, irradiance and temperature etc.(ii) Individual string power generation, voltage, current, irradiance and temperature etc.(iii) Total power generated of all strings, voltage, current, irradiance and temperature feeding to each invertor. (iv) input voltage, input current, output voltage, output current and power losses of each inverter.(v) Total power, voltage, current, temperature at input of solar transformer, also output parameters such as output voltage and output current of solar transformer. 52 EARLY STREAMER EMISSION (ESE)Supply, installation, testing & commissioning of 5m high, advance active on generating Early Streaner Emission (ESE) lightning arrestors with lightning counter to provide radius of protector of minimum 107 m at level-IV. The lightning arrestors shall conform to IEC 60099-4 or IS 3070 except to the extent modified in the specification. Arrestor shall be hemetically sealed units, self -supporting construction, suitable for mounting on lattice type support structurs complete as specified and directed by the EIC & shown in drawings. 53 Lightning Protection system on protective Early Streamer Emission (ESE) technology confirming by NFC 17-102-2011 and UNE 21186 Standard, Non electronics based deivce shall emit electronmagnetic impulse in the form of a streamer intothe air microseconds earilier than naturally.(i) Lightning impulse current (10/350 µs) in 100 KA tested (ii) Serial no mentioned in Each Model of Air Terminal quality certificate. (iii) Material metal housing stainless steel 304. (iv) central rod dia 20 mm elect/magnetic shielding (v) can be qualified in compliance of CPRI (central power research institute). Govt of India for the Impluse current of (8/20 µs) in 40 KA with 5 poistive & 5 negative impluse (vi) Covering radius 107 meter in Level-IV Protection with 8 mtr mast. 54 Lightning Air Terminal Adaptor. Supply of highly insulated polyplatic adaptor to fix the lighnting ESE air terminal with the mat. The adaptor shall have suitable metal connector/ connecting point in such a way the top portion shall be electrically connected to the central final trip (elevated sharp tip) of the ESE air terminal and the bottom portion shall be connected to the down conductor. 55 MAST GI (supporting mast): supply of GI mast for mounting the terminal & adaptor with the ESE air terminal i compliance with IEC 62561-1.(i) GI mast length:- 8 Mtr (ii) GI pipe heavy duty, bottom 80mm dia, 3m, middle pipe dia 65mm, 2m (iii) standard: IS 1239 Part I): 2004 (iv) Base plate: GI Base plate size (250x250x5mm) (v) both the GI mast to be connected with the help of 2 flanges with 4 GI plated nut bolt with washers. The base plate size in (300x300x6mm) GI with requisite fitted with 4 hold the mast. (v) Necessary concrete foundation, earth work for holding the lightning conductor in position is deemed to be included in quoted unit rate. 56 Guy Wire Kit: Supply of Guy wire GI Nickel coated 4mm dia. Covered with white sleeve for extra protection and avoiding rusting. Length of the Guy wire is 6 mtr x 3 no = 18 mtr with accessories like:(i) Guy wire Nickel coated with white convered waterproof sleeve-18 metre(ii) U clips - 6 nos (iii) Pin type zebra anchor fastner-4 nos (iv) O hook- type fastner/ eye bolt fastener-3 nos (v) GI nut bolt 12mm dia of suitable lenth - Nos as per site requirement. 57 Lightning Strike Counter: minimum sensitivity of 250 A at 100 KA.(i) Display Model: digital display (non- resettable type) (ii) Display Range: 000000 to 999999 (iii) Detected Maximum discharge current : 350 A, 10/350 microsecond wave (measurd according to NFC standards per IEC 60060-2)(iv) Tested as per IEC-60060-2 (v) Degree of protection : IP 65 (vii) Operating Temperature (*C): 20+~85 (viii) Strike count display 6 digt (ix) Standard NFC17 102 (2011) Make- Saboo Sysyems Pvt Ltd/KMV/ABB/Axis India Note: Item No 4.34 to 4.39 (i) Lightning arrrestor & its components shall preferably be supplied by same manufacturer. The installation shall be carried out by rep of manufacturer. Testing of LA shall be done in presence of Engineer- in- charge. 58 Chemical Gel Earthing system: Supply for advance chemical Gel earthing system of 1 No. of UL certified 7 CPRI tested environment friendly ground enhancing compund. The copper bonded rod shall be 3 mtr long, 17.2mm diameter 254 microns copper bonded steel rod surrounded with 25 Kg each or more quantity of resistance lowering grounding minerals ROHS certified. Distance between the rod shall be length of the rod all as shown on drawings.(i) Tested as per IEC 62561-2 (ii) CPRI tested at 5 positive & 5 Negative impluse 25 KA (iii) Meets the requirments as per IS 3043, IEC 60964-5-54, UL 467 (iv) Standard- As per IS-3043 & IEEE80-2000, Test certificate from NABL lab. Make : Pragati Electrocorp (P) Ltd Gurgaon / DEHN / JEF Techno 59 Pit Chamber-Round value box supply of FRP heavy duty UV resistance, weather proof earth pit cover as per OEM recommendations complete all as specified and diected. 60 M&L for UPVC pipes of 40 mm size for DC wires, having pressure capacity of 10 kg including fiting viz joints bends, tees, etc complete all as specified and directed. 61 M&L for UPVC pipes of 25mm size for DC wires, having pressure capacity of 10 kg including fiiting viz, joints, bends, tees etc complete all as specified and directed . Note:-(i) Earth work shall be measured and paid under relevant item. 62 M&L for perforated hot dipped galvanized iron cable tray having cable tray for AC & DC cable routine (300 x 50 x 5mm and 450 x 50 x 5mm) thickness 1.5 mm galvanization and perforation not more than 17.5% includeding fittings viz joints, bends, tees, etc in convenient section of length complete all as specified and directed. 63 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specifications:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip rod and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging handle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II class-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. 64 (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Separate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type (25 KA for 1 second) as per latest IEC:62271-200. (g) Vacuum bottles should be tested for 100 full short circuit operations. (h) Manual closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack battery backup for not less than 10 minutes. 65 (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contactor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 66 Supply, installation, testing and commissioning of three phase, 4 wire Bi-Directional HT CT/PT Digital Energy Meter automatic grade as per relevent IS, 110-240 V, (66 KV/Ѵ3/110/Ѵ3) industrial application, Optical Port, RS 232/485 communication current rating Imax 2A -/1A, automation grade, accuracy class 0.2s, D3M024 type and suitable to install between 66 KV Sub Station (Commercial supply of PSPCL) in replacement of existing PSPCL energy meter and 750 KWp Solar power plant, display parameters like KWh, KVArh, KVAh, KW, kVA, Frequency, Power Factor, Current, import and export of energey complete all as specified and directed by Engr-in-Charge. Make : Secure, model : Premier 300 or its technno commercial equivalent.Note : The contractor shall liaise with PSPCL for testing & calibration of the meter. Cost of the same deemed to be incuded in quoted rates. 67 ROAD/PATH/CULVERT 68 M&L for providing and marking broken centre/ side lines/zebra Lines, dashes, arrows etc on road pavement and the like of any description and width with thermoplastic paint hot applied with machine confirming to BS-3265 and according to the specification laid down by IRC and MOST (Mininstry of Surface Transpost) specification 2001 (4th revision) complete all as specified and directed. 69 EXTERNAL WATER SUPPLY 70 Construction of brick masonary valve pit of size 1000x1000x1000mm (internal dimension) with and including MS sheet cover fabricated from 3 mm thick MS sheet and frame of angle iron 40 mm x 40 mm x 5 mm with fixing arrangement hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil, returning, filling in approved soil, disposal of surplus soil to a distance not exceeding 50 metre, 150 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, brick work using pulverised fuel ash lime bricks in cement mortar 1:6, 15 mm plastering in cement mortar 1:4 both internally and externally, 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring complete all as specified and directed by Engr-in-Charge. 71 PVC HDPE rotational moulded 5000ltr capacity water storage tanks (Cylindrical vertical type with closed top) triple layered,fixed in position and making inlet and outlet water piping line connections complete all as specified. Note : Staging for PVC water tank shall be paid separately under respective item. 72 S&F Pumping sets, centrifugal monoblock, electric driven, single phase, 2HPhaving discharge capacity 3.2 LPS at 20 mtr head, suction x delivery size 50x40mm all as specified and directed by EIC. 73 Supply and fixing PVC air braided hose pipe 25mm dia. 74 M&L for provisioning of staging at 2 mtr height for PVC HDPE storage tank 5000ltr capacity. Note : S&F of PVC water tank of 5000 ltr capacity not included in this rate and shall be paid saparetly under respective item. 75 SEWAGE DISPOSAL WORKS 76 Supply and fixing ofLLDPE septic tank designed to carry sewage and sullage, water including excavation in anytype of soil, PCC 1:4:8, PVC Pipe from last manhole to septic tank, vent shaft, vent cowl and misc connection like PVC Tee, PVC bend etc. complete for PWTS-STBF-160-01 (1600 Lts Capacity) (Make - Sintex) 77 Soakage wells exc, in ordinary Soil, Foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / Filling with brick bats, complete of size 1.8 M dia X 3.0M deep. (CEJZ/STD-301/90 SHEET No 1/4to 4/4) 78 EXTERNAL ELECTRIC SUPPLY 79 Supply, installation, testing and commissioning of 11 KV, 630 Amp, 50 Hz, SF6 gas insulated, 21 KA/3 Sec 3 way Ring Main Unit of outdoor type, motor operated, extensible with 01 No. VCB 630 Amps as incommer and 02 Nos LBS as outgoing cable termination from front (Internal arc classification AFLR 21KA/1 Sec with bottom exhaust both for tank and cable box as per IEC:62271-200), enclosed in welded stainless tank having IP-67 degree of protection, leak rate of SF-6 gass less than 0.1% and tested as per IEC:62271-200, ring core type protection CT, line side isolator alongwith following technical specification:-(a) Electrical specification. (i) Nominal system voltage - 11 KV. (ii) Voltage variation on supply side - + 10 (iii) Corresponding higher system voltage - 12 KV. (iv) Transient condition - (-)20% or 10% combined variation of voltage and frequency. (v) Lightening impulse withstand voltage upto 75kVp. (vi) one minute dry/wet power frequency withstand voltage primiary - 28 KV. 80 (vii) Rated dynamic withstand current - 52.5 KA. (viii) No of short circuit operations at rated short circuit current of 21 KA for breaker - 50 Nos.(b) General specifications. All live parts, bus bars, shall be preferably be enclosed in non megnetic and non ferrite grade stainless steel tank grade SS-304 of minimum 2.5 thickness. The RMU shall be tested for internal arc test of 21 KA/1 Sec AFLR with bottom exhaust for safety of personnel for both tank as well as cable compartment as per IEC:62271-200. The outdoor enclosure shall have IP-55 protection for complete switchgears with top opening canopy & dedicated IP-55 cable compartment. The protection relay shall be for 3 o/c + 1 E/F (IDMT Type) self powered numerical protection relay with low and high set of over current and earth fault, MODBUS communicating alongwith RS-485 Port. Internal Arc classification should be with bottom exhaust only. The RMU should be SCADA compatible and trouble free operation at the temperature 40 degree C & above. 81 (C) Insulated Bus connected unit comprising of the following :(i)Air insulated enclosure with necessary bus connection via bushing VTs from manufacturer and according to IS:3156. (ii) Sinle phase bus PT for metering - 11 KV/rt3/110V/rt3, 50 VA, class 0.5. (iii)Auxillary transformer - 11 KV/230V AC, 1 KVA. (iv) Multifunction Meter - EM6400 NG class 0.5 for incomer(d) The following accessories should be included in deemed rate:(i) Antireflex operating hadle. (ii) Battery 24 V DC, 12 Ah. (iii) Battery charger 24V DC. (iv) Manometer with remote contact.Note : RMU should be manuctured, inspected by rep of the Acceptung Officer and invoiced from the OEM factory. 82 Supply, installation, testing and commissioning of Vacuum Circuit Breaker 630 Amps, having rupturing capacity 350 MVA, HT 11 KV, 3 phase 50 Hz, indoor type, totally enclosed metal clad constructed from Aluminium Zinc sheet steel of 2mm thickness for incomer as ICOG confirming to IEC-62271-200 complete with, overload and earth fault protection, ammeter, voltmeter complete as incomer circuit breaker all as specified and directed alongwith following technical specification:-(i) 630 Amps rating. (ii) Horizontolly draw out type. (iii) Trip road and have RoF type & Rack in Rack out motorised type. (iv) Motorised spring charging mechanism with integral spring charging hangle for manual spring charge. (v) Panel separation with every department like VCB, Metering, cable chamber & Bus bar chamber. 83 (vi) Cast resin current transformer 11 KV, 600-300/1+1A, core 1, class 0.5, 15VA wih metering and protection core including necessary control wiring & PT 11 KV, core-I class, 3 Pole, Core-II clause-0.5, 50 VA burden OVF 1.9 for 30 Second for metering & protection backed by HT & LT MCBs. (vii) Line PT should be mounted on rear side (top or bottom) of the panel. (viii) Accessories like local remote switch, breaker control through MCB, indicating lamp RYB, spring charging, DC supply healthy, breaker ON/OFF breaker in service/test, multi function meter with RS-485 port (EM-6400NG), Digital Ammeter and Volt Meter, (ix) Seprate master trip relay and anti pumping relay. (x) Comprehensive numerical protection relay should have built in integrated mimic compatible IEC-61850 for non-directional O/C, E/F,U/V, O/V protection type having following additional facility:-(a) Trip circuit supervision. (b) Distribution recorder. (c) Event log with date and time. 84 (c) Event log with date and time. (d) Conformal coating for harsh environment. (e) suitable to operate on 24 Volt DC for auxillary and control supply. (f) Fully internal arc type typed (25 KA for 1 second) as per latest IEC:62271-200. (g) Vocuum bottles should be tested for 100 full short circuit operations. (h) Mannal closing/tripping of CB with compartment door closed. (j) The panel shall be provided with power pack batter backup for not less than 10 minutes. (k) The height of the HT section should atleast be of 1400mm for human safety during the internal arc creation. (l) Breaker shall be provided with 6NO+1NC contacts for each position in service and test, (m) Wireless thermal sensor will be provided in each bus & each cable termination per panel, alongwith Zig-b contractor and the data of the same should be display on HMI. (n) The VCB shall be SCADA compatible. (o) The VCB interrupter, breaker & panel alongwith relay should be of same make for better coordination and better SCADA compatibility. 85 (E) Indicating lamps LED type(i) Breaker ON Red clolour - 01 No(ii) Breaker OFF Green Colour - 01 No(iii) Auto Trip indication amber colour- 01 No(iv) Trip circuit heathly clear - 01 No(v) Spring charged blue colour - 01 No(vi) RYB indication - 03 Nos(F) Accessories (i) Trip Neutral Close Switch - 01 No(ii) Space heater with thermostat - 01 No(iii) Local Remote Switch - 01 No(iv) 3 Pin Plug Connector - 01 No(v) MCB AC & DC - 02 Nos(G) Relays(i) Numerical relay 50/51/50N/51N, non communicable, non draw out type - 01 No(ii) Master trip relay - 01 No(iii) Auxillary relay for transformer (3 elecments) - 02 Nos 86 M & Lfor Boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure all as pecified and directed. 87 Supply, fixing, testing and commissioning of junction box incl AI bus bar with MCB SP 6A, 10 KA, C curve & PVC cable 2.5 sqmm 2 core weather proof, aluminium conductor upto 7.5 mtr length for connection for single or 3 incoming cable & for outgoing and single phase connection of secuirty light fitting from junction box , PVC conduit pipe upto junction box , enclosed in tehermo plastic enclouser,shock proof , weather , dust , rust & water proof internally embedded gasket with provision for cable entry of size 300x200x125mm alongwith MS clamps, through and incl suitable gland all as specified. 88 Supply, install , testing and commissioning of LT feeder pillar distribution panel board CPRI approved, outdoor type, weather/vermin proof, mae out of 3.15 mmm thick CRCA sheet duly powder coated of suitable size and medium channel 75mm base mounting frame double door factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type 3 phase and netural 200 Amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting busbar connection/linkage complete and conforming to IS : 8623 and IP 54 class of protection as per IS ; 2147 complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below completed and mounting the panel board on ground with PCC (1:3:6) , bedding upto a height 30cm above ground level complete all as specified and directed (OR CH/DH) 89 (a) Aluminium busbar 200 Amp for 3 phase & netural -1 Set. (b) MCCB 4 pole 100 Amps 25 KA at 415 V -1 No (incomig)(c) MCB TPN 32 amps, 10 KA , C curve -Nos (outgoing)-02 , spare-01). (d) MCB SP 16 A , 10KA , C Curve-2 Nos (for street lights). (e) Digital Voltmeter with selector switch 0 to 500 volt- 1 No. (f) Digital Ammeter with selector switch and CTs 0 to 500 Amps-01 No. (g) Timer switch with set of contactors - 1 No. (h) LED type indicator lamps (R 90 MANNING & OPERATION (M&O) UNDER PH-II 91 First year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following:-(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 92 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system.(b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs) 93 MANNING & OPERATION (M&O) UNDER PH-III 94 Second year manning and operation of 750KWp Solar Power plant round the clock by providing following staff on all days including Sunday and Holiday for trouble free functioning of the installation at Adampur to ensure maximum solar energy is fed to grid including following(i) Trouble free operation of the solar power plant. (ii) Monitor the performance of the solar plant by data logging. (iii) Monthly report preperation and reporting to customer on performance of power plant. (iv) Maintainance of module- periodic cleaning of module through water. (v) Schedule maintainance of invertor. (vi) Frequent testing of plant equipment by walk down checks to internal condition of equipments such as module perfomance, inverter test monitoring, system testing etc. (vii) Careful logging of operation data and periodically processing it to determine abnormal slowly detoriating conditions. (viii) Attendto emergency break down/repair of the component without any delay. (ix) Careful control and supervision of operation conditions (wide and rapid variation in voltage and frequency conditions do contribute to increase maintainance). (x) Regulate routine maintainance work such as keeping equipment clean, cleaning of solar PV Module, proper maintainance of inverters, maintainance of LT/HT cable lugs, Panels, MCCBs, Joints, 95 Transformer, VCBs etc of any type/size and capacity. (xi) Spare parts maintainance including replacement of defective parts. (xii) Securing all equipments/materials against damage/theft etc. (xiii) Keeping complete area neat & clean through spray chemicals and cleaning of grass at regular interval of time. (xiv) Servicing and maintainance of SCADA System and taking printout of all the data from SCADA once daily. (xv) The thermal imaging of PV Panels should be taken for checking its healthiness once as directed by the Engg-in-Charge. (xvi) The shutdown time of interval should be monitored and recorded. Min staff (s) to be employed (a)Sopervisor : 01 No in one shift of 8 Hrs ( 0800 Hrs to 1600 Hrs) having diploma in electrical Engg and having good knowledge of SCADA system. (b) Electrician (ITI Electrical) - 01 No in one shift (0800 Hrs to 1600 Hrs) (c) Helper (Min 10th pass) : 01 No in three Shifts. (0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs, and 2200 Hrs to 600 Hrs)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 7
48.
Power #9344905 Technical Bid
Construction Of 3.15Mva33/11Kv R/Stn At Saddamandi By Way Of supply installation testing and commissioning Of Transformer Bay, 11Kv I/D Switchgear, Common Misc Works At 33/11Kv Level.- 1 SITC 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME 2 SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 4 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 5 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 6 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 7 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 8 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 9 GI STEEL STRUCTURES 10 Galvanised Steel Structures 11 Galvanised Nuts & Bolts 12 SITC OF CONTROL CABLES 13 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 14 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 15 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 16 Lugs, Ferrules etc. 17 SITC OF CONDUCTOR & HARDWARE 18 Providing & Fixing 200 mm² ACSR Conductor Panther 19 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 20 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 21 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 22 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 23 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 24 SITC 11 kV INDOOR SWITCHGEAR OF 3.15MVA, 33/11 KV SUBSTATION 25 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+3)SET 26 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 27 11 kV3- Core XLPE 185 mm² armoured, FRLS 28 11 kV3-Core XLPE 120 mm² armoured, FRLS 29 11 kV Indoor Heat Shrinkable Cable 185 mm² Termination Kits 30 11 kV Outdoor Heat Shrinkable Cable 185 mm² Termination Kits 31 11 kV Indoor Heat Shrinkable Cable120 mm²Termination Kits 32 11 kV Outdoor Heat Shrinkable Cable120 mm² Termination Kits 33 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 34 9 Mtr. Long Pole(ST-410 SP33) 35 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 36 Galvanisedironof sorts 37 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Aliminium wound) (1no. Spare) 38 120 mm²PVCLT Cable 4 Core, armoured, FRLS 39 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 40 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of ize 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 41 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 42 MCCB ‐ 200 Amps 43 SITC OF COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATION 44 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 45 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 46 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 47 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 48 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 49 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 50 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 51 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 52 Cement Conceret R/B Wall in1:3:6 mix as per site requirement on the direction of concerned Engineer 53 SITC OF COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATION 54 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 55 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 56 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 57 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 58 Providing of Rubber Mat 1mx2m 19mm thick 59 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 60 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 61 Providing of Industrial safety Helmet 62 Providing of Rubber Gloves for 33 kV level 63 Providing of Rubber Gloves for 11kV level 64 Providing of Industrial Safety Belt with comfort foam reinforment 65 Providing of Safety volcanized rubber Shoes 66 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 67 Providing of HV Detectors all voltages with fibre rod 68 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 69 Providing of Forged Adjustable wrench of 22mm and 32mm size 70 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 71 Providing of Nose Plier 72 Providing of Normal Plier 73 Providing of Sledge hammer of 2Kg with handle 74 Providing of forged Chisel long shank type 75 Providing of HSS Cabron steel Hawk saw with frame and set of 6 blade with two sided teeths 76 Providing of Measuring tape of 12 feet spring loaded 77 Providing of Precise 1 feet long bubble based water level 78 Providing of 600 watt hand drill with drill bits of HSS Hammer type 79 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feet dimensions with different chambers 80 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 81 Providing of Screw driver tester neon lamp based 82 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 83 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 84 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 85 Providing of foldable multi-purpose aluminium ladder 86 Office Steel Chairs wih Armrest 87 Office Table of Standard Size with Sufficient Drawers 88 Office Almirah With Locker of reputed make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
49.
Power #9344903 Technical Bid
CONSTRUCTION OF 3.15MVA33/11KV R/STN AT UDHAN BY WAY OF supply installation testing and commissioning OF TRANSFORMER BAY, 11KV I/D SWITCHGEAR, COMMON MISC WORKS AT 33/11KV LEVEL.- 1 SITC 33 kV TRANSFORMER BAY OF SINGLE BUS SCHEME 2 SUB‐STATION MAIN EQUIPMENT 3 33 KV Vacuum Circuit Breaker (36 kV, 1250A, 26.2 kA, Outdoor Type) with allied accessories and heavy duty pad clamps. 4 33 kV Isolator with Without Earthing Blade with allied accessories and pad clamps(36kV,1250A, Outdoor,3 poles, 25 kA) with multi fingered female contacts with tin coated contacts, The isolator is to be provided a locking arrangement for un-authorized operation and auxilliary switch box (set of 3 Nos.). 5 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) 6 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less 7 33 kV C&R Panelalong with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Smart meter -5 Amps, DLMS Compliant with RS-485 port 8 33 kV Post Insulator Polymer 36kV,235kV Impulse, creepage distance 1224m 9 GI STEEL STRUCTURES 10 Galvanised Steel Structures 11 Galvanised Nuts & Bolts 12 SITC OF CONTROL CABLES 13 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 14 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 15 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS. 16 Lugs, Ferrules etc. 17 SITC OF CONDUCTOR & HARDWARE 18 Providing & Fixing 200 mm² ACSR Conductor Panther 19 Providing & Fixing of 630A T-clamps suitable for 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per relevant Standards 20 Providing & Fixing of Aluminium Tention Fittings of 0.2 ACSR Conductor having 8 no,s GI bolts of 19mm thick, as per Relevant Standards 21 Providing & Fixing Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN 22 Providing & Fixing of GI Earth wire 7/4.00 mm sq, with 4Nos. 13mtr long ST Poles for Shielding of 33KV Yard along with Power Transformer with proper earthingby GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm 23 Providing & Fixing of GI flat for earthing 50x6mm with epoxy insulator along with clampsas per relevant Standards 24 SITC 11 kV INDOOR SWITCHGEAR OF 3.15MVA, 33/11 KV SUBSTATION 25 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (1+3)SET 26 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) 27 11 kV3- Core XLPE 185 mm² armoured, FRLS 28 11 kV3-Core XLPE 120 mm² armoured, FRLS 29 11 kV Indoor Heat Shrinkable Cable 185 mm² Termination Kits 30 11 kV Outdoor Heat Shrinkable Cable 185 mm² Termination Kits 31 11 kV Indoor Heat Shrinkable Cable120 mm²Termination Kits 32 11 kV Outdoor Heat Shrinkable Cable120 mm² Termination Kits 33 11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch. 34 9 Mtr. Long Pole(ST-410 SP33) 35 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 36 Galvanisedironof sorts 37 100 KVA, 33/0.04 KV, 3-Phase Distribution Transformer with Bimetallic Terminal connectors Energy Level -2 (Aliminium wound) (1no. Spare) 38 120 mm²PVCLT Cable 4 Core, armoured, FRLS 39 Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole 40 Earthing of 100 KVA Substation-Excavation of earht pit of dia 650 mm & depth 3000 mm installation of earthing pipe of 40 mm Nominal bore & 4 mm wall thickness & length 2.5 mtr long as per IS 1239 GI Strip[ for neutral earthing of ize 75 mm x 10 mm & 50 mm x6 mm for connection of transformer body, G.O set & lightening arrestor as per IS 2629/85, GI Nuts & Bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. 41 Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or G.I Rod 20mm, 3.0 mtr long through welded with GI Strip 25x3 mm. 42 MCCB ‐ 200 Amps 43 SITC OF COMMON MISCELLENOUS WORKS IN 33/11kV SUBSTATION 44 G.I Chainlink Fencing of 33kv yard by way of mass concreting in foundations and chainlink fencing of 6 ft height using G.I Angle of size 65x65x6mm and G.I Flat iron 50x6mm 45 RCC Cable Duct for laying of 11 KV XLPE Cable from Power transformer to Control Room and Control Room to O/G Structures as per REC Approved Standard Drawing. 46 33/11 kV RCC Power Transformer Foundation (1:2:4) as per REC Approved Standarddrawing foundation complete job for 3.15 MVA Power Transformer 47 33 kV RCC Equipment foundation and Gantry foundationas per REC Approved Standarddrawing (VCB, Isolators, CTs, PIs, LAs etc) complete job 48 Earthing Mat using ( GI Flat 75 x 8mm) and (GI earth rod spikes 2.5 m long 20 mm dia), yard area, as per REC Standerd 49 Earthing Electrode ( 3m long 40mm dia GI pipe) through GI strip (50x6)mm for equipments 50 33 kV Yard concreting and metalling, yard area by providing, supply & laying 100mm thick PCC 1:4:8 using 20mm normal course aggregating and spreading 100mm three layer of 20mm single sized crushed/broken stone, as per REC Standerd 51 SITC of 120 Watts LED Street lights of following watts IP-66/67 protected with lens type LED, Pressure Di-cast aluminium body , 100+ LM/watt, Input voltage AC 85-265 Volts, efficacy 92%, life time more than 45000 Hrs. ( Crompton, Phillips, Jaguar, GE). To be mounted on 13mtr ST Poles including necessaryboxes/fabrication/modification as per requirement. ( the LED lights brand must have conducted the indian photometic test certificate of LM-79 and 80.) 52 Cement Conceret R/B Wall in1:3:6 mix as per site requirement on the direction of concerned Engineer 53 SITC OF COMMON MISCELLANEOUS EQUIPMENTS 33/11kV SUBSTATION 54 a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelenecopolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . 55 Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Doublebusbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories 56 Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCBs (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories 57 Providing of Bolt cutter of Taparia make BC-42 with allied accessories. 58 Providing of Rubber Mat 1mx2m 19mm thick 59 Providing of Fire ExtingiusherCo₂/ABCType of 4.5 kg capacity for controlroom 60 Providing of 3Sand Bucket Fire Extingiusherwith metallic stand andidentification plates 61 Providing of Industrial safety Helmet 62 Providing of Rubber Gloves for 33 kV level 63 Providing of Rubber Gloves for 11kV level 64 Providing of Industrial Safety Belt with comfort foam reinforment 65 Providing of Safety volcanized rubber Shoes 66 Providing of Telescopic Cabron fibre Earthing rod (set of 3 rods) 67 Providing of HV Detectors all voltages with fibre rod 68 Providing of Chrome vanadium forged Spanners of 10mm to 32mm sizering/u shaped. (set of 10 No.s) 69 Providing of Forged Adjustable wrench of 22mm and 32mm size 70 Providing of Screw drivers setflat cum star bit type dual end (set of 8 no.sof different sizes) 71 Providing of Nose Plier 72 Providing of Normal Plier 73 Providing of Sledge hammer of 2Kg with handle 74 Providing of forged Chisel long shank type 75 Providing of HSS Cabron steel Hawk saw with frame and set of 6 blade with two sided teeths 76 Providing of Measuring tape of 12 feet spring loaded 77 Providing of Precise 1 feet long bubble based water level 78 Providing of 600 watt hand drill with drill bits of HSS Hammer type 79 Providing of Tool Kit case plastic of Harry-kerry make of 2.5x1x1.5 feet dimensions with different chambers 80 Providing of Clamp meter with multi measuring parametersMarkoni/motwane/fluke make 81 Providing of Screw driver tester neon lamp based 82 Providing and fixing of industrial heavy duty chain block of 1 Ton capacitywith allied accessories complete 83 Providing of Chrome make socket set with ratchet and extension bars of10mm-32mm size sockets with allied accessories 84 Providing of Aluminum industrial ladder split 40 feet extension type withallied accessories 85 Providing of foldable multi-purpose aluminium ladder 86 Office Steel Chairs wih Armrest 87 Office Table of Standard Size with Sufficient Drawers 88 Office Almirah With Locker of reputed make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
50.
Power #9329427 Technical Bid
Supply, Fabrication and Erection of GI steel structures, earthing materials, Station equipments, Control panels, control cables, painting, handling of department equipments etc., for the upgradation of existing Muttam 33/11 kV SS into Muttam 110/33/11 KV SS in Cuddalore EDC- 1 Steel Items 2 Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint and first finishing coat of Aluminium Paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site.Non-specfied structures, Extension, Alterations, and Deductions as per station requirement. - Light section (other than Heavy section) 3 GI STEELS: Supply of various types of hot dip galvanised fabricated steel structures confirming to IS 2062 Gr A at site as per the std.design/ Drawing, including Freight & Handling, Loading, unloading, Labour, machinery and Consumables and as directed by the field Engineer at the SS site 4 110 KV Take Off/Strung Bus structure using Double Butt pole 200x100 RSJ. 5 110 KV Take Off/Strung Bus structure using Single pole 250x125 RSJ. 6 110 KV Power Transformer Gantry 7 110 KV AB Switch Structure 8 110 KV Pie Support Structure 9 110 KV CT or PT Structure 10 110 KV LAS Structure below Strung bus 11 Supply of various types of steels including Cost of steel, Freight &Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint and first finishing coat of Aluminium Paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables, and as directed by the field Engineer at the SS site. Other Station Structures 12 110KV Breaker Plat form 13 33/22 KV Breaker Plat form 14 Yard Fire Stand frame with Top Canopy cover 15 Battery Room Fire Stand 16 AC Junction Box fixing frame 17 Labour for the Erection of the fabricated steel structures at the SS site with Supply of GI Bolts, Nuts & Washers(Spring/Flat as required) confirming to IS including Labour, machinery and Consumables as required & as directed by the field Engineer. 18 110 KV Take Off/Strung Bus structure using Double Butt pole 200x100 RSJ. 19 110 KV Take Off/Strung Bus structure using Single pole 250x125 RSJ. 20 110 KV Power Transformer Gantry 21 110 KV AB Switch Structure 22 110 KV Pie Support Structure 23 110 KV CT or PT Structure 24 110 KV LAS Structure below Strung bus 25 33/22 KV Feeder Bay Structures with 4 Bays + 1 LV 26 Non-specfied structures, Extension, Alterations, and Deductions as per station requirement. 27 Light section (other than Heavy section) 28 Other Station Structures 29 110KV Breaker Plat form 30 33/22 KV Breaker Plat form 31 Yard Fire Stand frame with Top Canopy cover 32 Battery Room Fire Stand 33 AC Junction Box fixing frame 34 Supply and fabrication and erection of Eye Bolts/ grout bolt with 20/22 mm rod confirming to IS with propoer threading and 2 Nos MS Nuts as directed by the field engineer. 35 Grout Bolt 36 Eye Bolt 37 EARTHINGS: Supply of Various types of Steel materials confirming to ISS 2062 –Gr A including VAT, Freight, Handling, etc., at site for Earthing with Labour for Fabrication & erectionfor Earthing including Labour, Machinary and Consumablesas as Required and as directed by the Field Engineer. 38 Labour for excavating and refilling of earth /trench for earthmat, cable, etc., of any size/depth narrow excavation as directed by the field engineer. - Semi density Rock soil 39 Providing Earth bore 140/150 mm dia using power rig or 100/125 mm dia using hand bore set including the labour, lead, lift etc., sedimentary strata of clay & sand stone shale pebbles boulders etc., for earth Pits with supply and providing of Bentonite powder(Sodium Bentonite) 5Kg /Mtr depth of the bore mixed with low resistivity earths as directed by the field Engineer (Earth to be supplied by the contractor) 40 Supply and providing of 450-600 mm dia, 300 mm height, 36 mm thick cement collar for identification of earth electrode location as directed by the field engineer. 41 Labour for the loading/unloading/shifting of Department materials at stores or site by the Contractor WITHOUT using Boards crane for one operation. Non-Fragile Materials 42 110 kV Isolators 43 33/22/11 KV Isolators 44 Cables/Conductors including cutting and rewinding 45 Bus Bars 46 Steel Items 47 Fragile Materials- 110KV Breaker 48 33/22/11 KV Breaker 49 230/110 KV CT/PT/LAS/CVT/CC/WT/Others 50 33/22/11 KV CT/PT/LAS/DT/Others 51 110 V DC Battery Sets 52 110 kV Insulators 53 33/22/11 KV Insulators 54 AC/DC/C&R Panels of Non grid type, Single feeder Control/Relay Panels of Grid type 55 Labour for the erection of Strung bus and all related hardwares, fittings, clamps including Meggering, hoisting of insulators and consumables and as directed by the Field Engineer. 56 110 kV Sigle Conductor Strung Bus / Phase 57 Up to 33 KV Sigle Conductor Strung Bus / Phase 58 Labour for the erection of Insulator single pole stack for supports/Underhang including Meggering & other consumables and as directed by the field engineer. 59 110 kV or 66 kV 60 Up to 33 KV 61 Labour for the erection of Busbar including suitable Modifications of End Clamps, providing holes wherever necessary as directed by the field engineer 62 75 mm (1 length) 63 75 mm with Bend(1 length) 64 50 mm (1 length) 65 Labour for the Erection of Jumper/Droppers using Moose/Zebra/panther Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field engineer. 66 POWER CONNECTORS: Supply of Aluminium Power Connectors/Clamps/Fittings with SS Bolts and Nuts, including VAT, frieght etc.,confirming to IS confirming to ISas per the drawing and specification. 67 6- Bolt Tension fitting 68 4-Bolt Tension fitting 69 Switch end Clamp for Zebra 70 Switch end Clamp for Panther 71 Switch end Clamp for Mink 72 Switch end Clamp for 75 mm Bus 73 Switch end Clamp for 50 mm Bus 74 Seating Block for 75mm Busbar 75 Seating Block for 50mm Busbar 76 T Clamp for Zebra to Zebra 77 T Clamp for 75 mm Busto Zebra 78 T Clamp for 50 mm Busto Zebra 79 Free end clamp for 75 mm 80 Free end clamp for 50 mm 81 Reducer Clamp for 75 MM Bus to Zebra 82 PG Clamp for Zebra 83 PG Clamp for Panther 84 75 mm Corona Bell 85 50 mm Corona Bell 86 OUT DOOR BRAKERS: Labour for the Erection of 230/110 KV Breakers complete setusing Crane with proper levelling, proving holes cutting, jointing, bending of pipes wherever required and filling of SF6 gas, Providing conductor jumpers from the Breaker to CTs & Isolators, Supply & Erection of Earthing steels two Riser to Breaker Structure from Earthmat/electrode using 65x10 MS Flat Providing Flexible Copper Earthing loops to the Breaker earthing points, Supply & painting of first primer coat of redoxide and two coats of Bus green Enamel paint on to the Earth risers inculing cost of reputed make paints, consumable, ,, frieght, etc., and as directed by the field engineer. - 110 KV Breaker using Crane arranged by the Contractor 87 Labour for the Erection of 33/22/11 KV Breakers complete set using Crane with proper levelling, proving holes cutting, jointing, wherever required, Erection of 3 Nos CTs without crane, Providing conductor jumpers from Isolator/Bus to Breaker, Breaker to CTs, CTs to Isolators, Supply & Erection of Earthing steels Four Risers Breaker Structure from Earthmat/electrode using 50x08 MSF, Providing Flexible Copper Earthing loops to the Breaker earthing points, Supply & painting of first primer coat of redoxide and two coats of Bus green Enamel paint on to the Earth risers including cost of reputed make paints, consumable, frieght, etc, and as directed by the field engineer. - 33/22 KV Breaker using Crane arranged by the Contractor 88 MEASUREMENT TRANSFOREMER : Labour for the erection of 3 Nos Measurement transformer using crane, Supply and erectioon of earthing steels using( 65x10 for 230 KV SS ) 50x8 MSF & Flexible copper loops to CT/PT for equipments & Junction Box earthing structure earthing, erection of CT/PT Junction Boxes, supply and erection of fixing steels, Painting of Primer redoxide, Two Coats of Bus Green enamel paint on earthing steels with supply of reputed make paints, including, frieght & all consumables as directed by the field engineer. - 110 kV using crane arranged by the Contractor. 89 Labour for the erection of Potential Transformers, Supply and Erection of Earthing steels using 50x8 MSF & Flexible Copper loops to equipment & Junction box earthing, structure earting, Erection of Junction boxes, Supply and erection of Fixing steels, Painting of Primer Redoxide, Two coats of Bus Green enamel Paint on Earthing steels with supply of reputed make paints, including frieght & all consumables as directed by the field engineer. - 33/22 KV Bus PT (3 units) 90 ISOLATORS & HG FUSE SET: Labour for the Erection of Isolators to correct alignment , including the cost of Consumables and lubricants, Meggaring, replacement of insulators if necessary etc, Supply and erection of Earthing steels to Isolator Bases, Insulators, ABS Booms, Poles, Earth Blades, operating Mechanism earthing etc., using (65x10 MSF for 230 KV SS) 50x8 MSF, Supply and Erection of 25 x 3mm² Flexible Copper to the centre Rotating Insulators, Mechanism Box etc, Supply and Applying of one coat of Primer Redoxide paint and Two coats of Bus Green Enamel Paint on earthing material including VAT, Freight, consumables etc.,.as directed by the field engineer. 91 110 KV Isolators With Earth - hand Operated 92 110 KV Isolators W/O Earth - hand Operated 93 33 KV Isolator 94 Labour for erection of LAS station type with surge monitor/ accessories etc., (3 Nos single pole stack) including Supply and erection of Earthing steels, (connecting to earth electrode & mat) Supply and Painting of Primer Paints and Two coats of Enamel Paints of reputed make, including frieght, consumables etc., as directed by the filed Engineer. 95 110 KV LAS with surge Monitors. 96 33/22/11 KV LAS 97 CONTROL ROOM MATERIALS: Labour for the Erection of Control Panels includings consumables as directed by the field engineer. - Simplex type/AC/DC/C&R Panel of Non-Grid type, Battery Chargers, Single feeder Control/ Relay Panels of Grid type (P&C) 98 Labour for Erection of Battery set including two coats of painting of Acid proof paint on wooden stand and neatly stacking the Battery cells and fixing of connecting plates including any modifications/ alterations required as directed by field engineer - 110 V DC , 120 AH 99 Labour, Consumables for the Initial filling and First Charging of the Battery to the required AH input and thereafter atleast 3 cycles of Charge / Discharge of the Battery set till the battery is charged to its full Capacity as directed by the field Engineer - 110 V, 300/120 AH 100 Supply and Erection of 5m Grouting type lamp post of B class MS pipe (3 inch dia for 3mtrs & 2.5inch dia for 2mtrs) including single/double fitting (Straight or V type) fixing arrangements, 1 inch dia B class pipe arms, yard light box fixing flat and one coat of redoxide and one coat of aluminium paint. 101 Supply and Erection of reputed make street light fitting with 1x(70-75)W or 2x(35-40)W, 240V CGL/ PHILIPS make LED Light. 102 Supply of Erection of yard light fuse unit mounting box of size 200x200x150mm (BxHxD) out of 18 SWG (1.22mm) M.S Sheet including primer paint as per Drawing including the Supply, Fabrication and Erection of Box fixing Flat using 50x8MSF, Two coat of enamel paints, provided with 16/20A rewirable Porcelain Fuse carrier unit, 16 A Bakelite connenectors including its cost materials, consumables, frieght, etc and as directed by the fiels engineer on site requirements. (The box shall be vermin proof, shall be provided with sturdy hinges, with provision for cable entry and locking arangements). 103 Fabrication, supply and fixing of C.T/P.T junction box of size 400x300x150 mm of 16 SWG(1.6mm) M.S.sheet with primer coat paint, Supply, Fabrication and erection of Box fixing Flats using 50x8 MSF, Supply and Fixing of 25x3mm² Braided Flexible Copper loops to box earth., Two coat of Enamel Paint, provision for fixing terminal blocks/ MCBs including consumables, fright, etc., as directed by the field engineer on site requirements. (The box shall be vermin proof shall have sturdy hinges, & locking arrangements 104 Fabrication, supply and fixing A.C.distribution box of size 750x750x250 mm out of 14SWG (2mm) M.S.Sheet including primer paint coat, Supply, Fabrication and Erection of Fixing Flat using 65x10MSF, supply & fixing of 3 nos 200A and 6 nos 100A Porcelain fuse units, Supply and Painting of Two coat of Enamel Paint including cost of materials, consumables, fright, etc., as directed by the field engineer. The box shall be vermin proof shall have sturdy hinges, provision for mounting MCB and MCCB, detachable gland plate and locking arrangements. 105 Labour for erection of C.T/P.T junction box 106 PAINTING: Supply and Labour for the Second Finish Coat of Aluminium paint on standard Steel Structures including cost of Paints of reputed make, Consumables etc., as directed by the field Engineer. - 33/22 KV Feeder Bay Structures with 4 Bays + 1 LV 107 Labour charges for two coats of enamel painting in substation structures, steels etc., including the cost of reputed make paints and other consumables as directed by the field engineer.Other Station Structures 108 110 kV Breaker Plat form 109 33/22kV Breaker Plat form 110 Yard Fire Stand frame with top canopy cover 111 Battery Room Fire Stand 112 AC Junction Box fixing frame 113 250 x 125 RSJ Pole Bottom (height 0.45 to 0.5 m ) 114 200 x 100 RSJ Pole Bottom (height 0.45 to 0.5 m ) 115 Yard Light Pole Bottom 116 Labour charges for writing details in any finished surface/board including cost of enamel paints and other consumables as directed by the field engineer. 117 CABLES: Labour for erection of cable in duct / trench/clamping on structures neat laying in the ducts with identification aluminium tags in all duct corners for easy identification of cables including fabrication of clamps and fixing at uniform intervels as directed by the field engineer. 118 Up to 8 core 119 Above 8 Core 120 STATION ACCESSORIES: Supply and glanding of ISI mark cable gland of suitable size of reputed make including removing of insulation of cables and providing suitable holes as required and as directed by the field engineer. 121 16/19 mm 122 22/25 mm 123 28/32 mm 124 Supply and termination of cable core end dressed neatly including the cost of cable socket (Lug) ferrules, sleeves, tags, ties, strops, etc asdirected by the field engineer. (No. of core ends in unit of 1000 ) 125 Supply and erection of Vinyl Sticker cutting/ Printing on Vinyl Sticker/Foam board to be used for main equipment, slogan, name board & any other purpose of required sizes as directed by the field engineer. 126 Supply and erection of B class G.I.pipe for extension of tandem/down pipe for A.B.Switches and for any other work required as directed by the field engineer. - 40 mm Dia 127 Supply and provision of 12/25x3mm flexible braided copper / copper flats as required and as directed by the field engineer. 128 Supply &Crimping of Copper Lugs of Suitable sizes as required and as directed by the field engineer. 129 Supply and fixing Fuse unit of reputed make with ISI as directed by the field engineer including drilling &fixing. HRC Backlite Fuse units 130 16 AMPS 131 32 AMPS 132 Supply and fixing of HRC fuse of reputed make as directed by the field engineer. 133 2/5/10 Amps 134 32 AMPS 135 Supply and fixing of Hylem board 8/10 mm thick wherever required as directed by the field engineer 136 Supply and fixing of MCB of Havells/Schneider/ MDS/ Reputed make with ISI mark wherever required as directed by the field engineer. 137 32 AMPS - 3 phase, 4 pole 138 16 AMPS - single phase, single pole 139 Supply and fixing of AC single/ 3 phase 4 pole 415V ISI mark changeover switch of reputed make iron glad metal switch as required and directed by the field engineer. 140 32 Amps ( Single Phase- DPDT) 141 63 Amps ( 3 Phase- FPDT) 142 Supply and fixing of terminal blocks as directed by the field engineer. 143 Regular Type ( Non Disconnecting ) 144 Disconnecting type( Link type) 145 Supply and provision of M8,M10,M12 and M16 (full /Half thread)G.I.bolt and nuts of various sizes including plate/spring washers as required and as directed by the field engineer. 146 Supply & fixing of LC/Key board out of 75x 25 mm Alu. frame embedded with 12 mm pre-laminated wood particle board using screw on rear side, 2 Nos plain glass sliding shutter of 5 mm thick fixed with metal roller on Alu.channel with locking arrangements, glass piece handle shutters, wall clamp as directed by the field Engineer including cost of all materials & all consumables 147 Supply and fixing of godrej 6 lever navtol lock with triplicate keys for A.B.Switches and for any other purpose including the cost of ring and key token as directed by the field engineer. 148 FIRE FIGHTING EQUIPMENTS: Supply & providing of Mechanical foam type fire extinguisher with all accessories conforming to IS 149 50 litre trolly mounted 150 9 litre portable 151 Supply & providing of DCP (Dry Chemical Powder) type fire extinguisher with all accessories conforming to IS 152 25 KG Trolly Mounted 153 9/10 KG Portable 154 5/6 KG Portable 155 Supply and fabrication of sand drums, (size of 580mm dia & 420 mm height) with conical cover made of tin sheet to be provided with handle including the cost of barrel and other consumables as directed by the field engineer inlcuding the cost of sand. 156 Supply & Providing of Fire Buckets 10 Ltrs Capacity 157 Supply of fire fighting equipments Display Boards and as directed by the field Engineer. 158 Supply of First Aid Box and Artificial Respiration kit and as directed by the field Engineer. 159 Supply of Digital wallclock with including Time, Date/ month/ year, Temperature etc., 160 Supply of Aluminium self supporting extension ladder 35feet Length as per IS Standardas directed by the field Engineer. 161 Supply of Aluminium self supporting extension ladder 10feet Length as per IS Standard as directed by the field Engineer. 162 Supply of Telescopic Earth Rod with copper wire 10feet (SS type) as per IS Standard as directed by the field Engineer. 163 Supply of Discharge rod 10feet (SS type) as per IS Standard as directed by the field Engineer. 164 Supply of earth rod 10feet (SS type) as per IS Standard as directed by the field Engineer. 165 Supply of rubber gloves as per IS Standard as directed by the field Engineer. 166 Supply of rubber gauntlets as per IS Standardas directed by the field Engineer. 167 Supply of Emergency light with rechagreable battery as per IS Standard as directed by the field Engineer. 168 Supply of rechargeable High beam Torch light as per IS Standard as directed by the field Engineer. 169 Supply of 5kV Digital Insulation tester as per IS Standard and Specification as directed by the field Engineer. 170 Supply of 1kV Hand Operated Insulation tester as per IS Standard and Specification as directed by the field Engineer. 171 Supply of Digital Multimeter as per IS Standard and Specification as directed by the field Engineer. 172 Supply of Digital Earth tester as per IS Standard as directed by the field Engineer. 173 Supply of Rubber mat 2000*1000*10mm as directed by field Engineer. 174 Supply of Tools Kit (spanner set size upto 32mm make:Taparia) as directed by the field engineer. 175 Supply of BELT ROPE WHITE COTTON 16MM as directed by the field engineer. 176 Typing & printing of Commisioning reports, Booklets, Drawings including spiral Binding/stick file cost etc., 177 SGST & CGST (If applicable quote the value, if not enter 0) 178 IGST (If applicable quote the value, if not enter 0)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
TenderDetail
Loading tenders