View Bid Results For Time Relay Tenders

We found 2224 Bid Results related to time relay tenders. You can find Contractor details who won time relay tenders along with contract details in Bid awards announcements section.

Filters
Stage
1776
254
194
Tender Publishing Platform
475
1749
State / UT
36
288
248
246
129
125
117
98
97
93
82
79
73
71
70
65
62
60
41
40
34
25
21
13
12
7
7
4
4
3
2
2
2
1
1
1
1
Contract Value
672
644
660
244
Publish Date
4
1
0
0
0
Sector
30
436
421
177
174
164
136
121
113
82
67
46
41
40
36
33
32
22
21
14
13
10
6
4
4
2
2
2
1
1
1
Ownership
7
1132
475
377
207
27
3
1
Within keyword
Active filters:
Showing 1–45 of 2224 tenders matching your filters
Contract Date: Jul 02, 2026 Contract Value : 3.97 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
5.
Public Administrative Department #11415442 Price Bid
Tender for Site Of Ccms At Various Places Of Municipal Board Marwar Junction Area -Supply installation testing & commissioning of IK08 & IP56 3 phase 440V 50Hz, 7.5kw capacity centralized control and monitoring system panel (CCMS) made of fire retardent SMC steel material having lock & suitable for schedule on/off of street lights having following provision: Inbuilt on chip integreted energy metering with 3 nos CT having class 1 accuracy, Three phase auto phase selector power supply with withstanding capability up to 500 VAC, Instant mode, Fixed Mode, Astronomical Mode, Hybrid Mode, Interval Mode, Offset in Sunset and Sunrise Timing for scheduling, Provision for measurement of all three phase electrical parameters like voltage, current, power factor, power, frequency, energy with atleast class 1 accuracy and compliant with IS13779 standard, UV-OV protection, backup battery 8 hrs, Andriod/iOS app and software to operate form computer, provision to add display device externally, support for RS485 communication, inbuilt GSM/GPRS 4G modem modem with 2G fallback, Real time GPS based clock, calendar, lithium ion battery backup for RTC clock, Three relay output, Minimum Ninety days data memory inbuilt backup facility, Controller shall be type tested with NABL approved lab for EFT or burst testing for conducted immunity in accordance with IEC 610000-4-4, For Future upgradation CCMS panel shall supports wireless Low Power Sub Ghz (865-867 MHz) communication with a maximum 100 nos. of individual node/Luminaire controller which can monitor ON/OFF status & Flicker detection of led lamp up to 400W. Network should support self-forming and self-healing RF mesh with open field range of 200 m. CCMS panel enclosure shall be made of Mild Steel material of minimum 16 gauge with MS base sheet of appropriate thickness. It shall have Four Pole Incoming MCB of 63 Amp, Single Pole Outgoing MCB of 32 Amp, 3 latching Relays with 63 Amp and 2P Rotary switch and MCB for Maintenance and Bypass Operation. Software should have undergone a Vulnerability Assessment and Penetration Testing (VAPT) as per OWASP, SANS CWE 24 or CERT-In Standard. Dedicated IoT communication GSM/GPRS SIMCard (with minimum 2 years of recharge)for 4G Communication with software application. 2 Year Data Hosting & Server Charges to be included with software. Software application should utilize a Low-Code/No-Code platform to simplify development and customization. It must be hardware-agnostic and compatible with other loT-based smart city applications. Pole mounting/surface mounting stand shall be included.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
6.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
9.
Power #11391976 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 220 Kv Substation Pilibhit Etsd Pilibhit; Substation, Switchyard; Service Provider - Inspection And Rectification Of Nulambo Make Sas Installed At 220 Kv S/S Pilibhit, The Following Works Are Including For Healthy Scada Communication:- , Replacement Of Defective Armored Optical Fiber Cable Splicing It If Required Any Anywhere In The Ring. , Replacing The Defective Fo Multimode St-St Port Patch Cord. , Checking And Rectifying The Healthiness Of Liu S And Its Communication Port. , Checking And Rectifying The Healthiness Of Iec 61850-7 Ethernet Switches. , Replacing Of Defective Cat -5/Lan Cable And Checking Its Healthiness. , Rectifying Communication Healthiness Mod Bus Rtu For Various Mfm Meters. , Rectifying And Checking Healthiness Of Gps System And Is Synchronization With All Relays. , Checking Of Healthiness Of All Protection Relays. , Reinstallation Of Old Backup To Scada Communication To Scada. , Checking Of All Required Event,Alarm,Numerical Dates Status And Signals To Scada From Various Bay And Feeders. , Checking The Sld Of S/S Scada Screen. , Checking Of All Required Operations Of Equipment Of Scada. , Configuration Of Ethernet Switches/Modems/Rtu Etc If Required. , Installation Of New Window For Nulambo Automation Software In Stand By Pc And Reinstalling The Old Backup Of Hmi -2 Making Both Hmi-I In All Respect At The Time Of Rectification All Required Material And Computer Parts Will Be Arranged By Department Without Extra Charges Execpt The Following Given Material Will Be Provided By Contractor. Scada Liecence Key, Activation Key, Old Sas Backup And Software Cd Will Be Provided By Department. , Supply:- , Supply Of Fiber Optical Multimode Patch Card Fot St-St Port. (Each 5 Meters) , Supply Of Fiber Optical Multimode Patch Card Fot Lt-St Port. (Each 10 Meters)
Contract Date: Ref. Documents Contract Value : 1.94 Lakh
Government Departments No of Bidders 4
Uttar Pradesh View Result →
12.
Power #11351298 Technical Bid
Tender for Procurement Of Minilec Make Various Timers, Relays Etc For 2X600mw, Sstpp, Mppgcl, Dongalia. , Single-Phase Preventer With Under And Over Voltage Protections. Model: Alv D2 System Supply: 415 V Ac Auxiliary Supply: 380 - 415 - 440 V Ac Protections: Single Phasing, Phase Sequence Reversal, Phase To Phase Voltage Unbalance, Under Voltage And Over Voltage Trip Delay: 3.5 ± 1.5 Sec. Output Contacts: 2 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Single-Phase Preventer. Model: Vsp D2 System Supply: 415 V Ac Auxiliary Supply: 240 V Ac Protections: Single Phasing, Phase Sequence Reversal, Phase-To-Phase Voltage Unbalance Unbalance: 30 V - 70 V Ac Trip Delay: 3.5 ± 1.5 Sec. Output Contacts: 2 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Single-Phase Preventer. Model: Vsp D1 System Supply: 415 V Ac Auxiliary Supply: 240 V Ac Protections: Single Phasing, Phase Sequence Reversal, Phase-To-Phase Voltage Unbalance Unbalance: 40 V Ac Trip Delay: 3.5 ± 1.5 Sec. Output Contacts: 1 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Under And Over Voltage Relay Model: D2 Vct1 (Upgraded Version Of Vcf D2) System Supply: 380 - 415 - 440 V Ac Protections: Under Voltage, Over Voltage And Neutral Fail Trip Delay: 1 - 10 Sec. Power On Delay: 1 - 10 Sec. Output Contacts: 2 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Single-Phase Preventer With Under And Over Voltage Protections. Model: S2 Vmr3 System Supply: 380 - 415 - 440 V Ac Protections: Single Phasing, Phase Sequence Reversal, Phase To Phase Voltage Unbalance, Under Voltage And Over Voltage Unbalance: 2% - 20%. Trip Delay: 1 - 10 Sec. Under Voltage: 285 - 425 V Ac Over Voltage: 400 - 520 V Ac Output Contacts: 2 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Water Level Controller Model: Wlc D1 With 3 Sensors. Auxiliary Supply: 415 V Ac Output Contacts: 1 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Multifunction Timer Model: D1 Etm1 Auxiliary Supply: 24 - 240 V Ac / Dc Operations: On Delay, Cyclic Delay On First, Cyclic Delay Off First, Interval Delay, Star Delta, Engine Start Delay, Instantaneous & Delayed Time Range: 0.1 Sec. - 100 Hrs. Output Contacts: 1 Construction Of + 1 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , On Delay Timer Model: S1 Ets1 Auxiliary Supply: 240 V Ac Operations: On Delay Time Range: 3 Sec. - 30 Sec. Output Contacts: 1 Construction Of Contact Rating: 5A @ 240 V Ac (Resistive Load) Mounting: Din Rail , Phase Failure Relay Model:- D2 Vmr 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
13.
Coal and Mines #11337639 AOC
Bids Are invited for Custom Bid For Services - Electrical Works For Maintenance Of Quarters And Manoranjan Kendra Of Urjagram Colony, Wani Area Under Mission Sehat - Point Wiring For Light/Bell/Exhaust Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Materia + Labour) , Point Wiring For Independent Plug In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Sw (Materia + Labour) , Point Wiring For Light/Bell Concealed Type In Min 20 Mm Hms Pvc Conduit With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No. Wg-Pw/Cw (Materia + Labour) , Point Wiring For Independent Plug, Concealed Type In Min 20 Mm Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wires, Modular Type Switch And Socket, Earthing And Required Accessories As Per Specification No Wgpw/ Sw (Materia + Labour) , Supplying Modular Type Switch 6A/10A On Provided Plate And Box With Wiring Connections Complete. ( Materia Only) , Supplying Modular Type Switch 16A On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type Bell-Push 6A/10A On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type 3 Pin 6A Multi Socketwith Safety Shutter On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying Modular Type 3 Pin 6/16A Multi Socket With Safety Shutter On Provided Plate And Box With Wiring Connections Complete. (Materia Only) , Supplying 6A 3 Pin Plug Top Bakelite Type Of 230V A.C. Supply. (Materia Only) , Supplying 16A 3 Pin Plug Top Bakelite Type Of 230V A.C. Supply. (Materia Only) , Supplying Flush Type Shockproof Plug Socket 6A & 16A (6 Pin) With 16A Switch Combined With Indicator L And Fuse With Gang Box On Wooden Board. (Materia Only) , Supplying Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Mains With 2X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No. Wg-Ma/Bw (Materia Only) , Supplying Pvc Insulated Pvc Round Sheathed Fr 1.5 Sq.Mm (30 No. X 0.25Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia Only) , Supplying Pvc Insulated Pvc Round Sheathed Fr 2.5 Sq.Mm (50 No. X 0.25Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia Only) , Supplying And Erecting Pvc Insulated Pvc Round Sheathed Fr 4 Sq.Mm (56 No. X 0.30Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv (Materia + Labour) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Wire Armoured (Round) Cable 1100 V, 2 Core 4 Sq Mm Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu (Materia + Labour) , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Wire Armoured (Round) Cable 1100 V, 2 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu (Materia + Labour) , Supplying Hms Pvc Conduit 25Mm Dia. With Pvc Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Materia Only) , Supplying Pvc Trunking (Pvc Casing-N-Capping) Of Size 20Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Materia Only) , Supplying Pvc Trunking (Pvc Casing-N-Capping) Of Size 25Mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Con. (Material Only) , Supplying Pvc Box Trunking Of Size 50X50mm With Accessories On Wall/Ceiling As Per Specification No. Wg-Ma/Box. (Material Only) , Supplying Gi Flexible Conduit 25Mm Dia. Conforming To I.S. With Required Number Of Couplings, Bushes, Check Nuts Etc. Complete (Material Only) , Supplying Spmcb 6A To 32A, C-Series With Rated Short-Circuit Breaking Capacity(Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Sp Mcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Dp Mcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying Fp Mcb 40A To 63A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Mcb (Material Only) , Supplying 4 Pole Isolator Only Switch Version Of Miniature Circuit Breakers Of 80/100A In Provided Distribution Board. (Material Only) , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 8 Ways (8 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Provided Iron/Gi Frame As Per Specification No. Sw-Mcbdb (Material + Labour) , Supplying & Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 10 Ways (10 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection Provided On Iron/Gi Frame As Per Specification No. Sw-Mcbdb (Material + Labour) , Providing, Erecting And Commissioning 2 Pole Rccb Only Of Electromagnetic Type With 30/100/300 Ma Sensitivity And Having Capacity Of 40A Complete As Per Specification No. Swrccb/ Rccb (Material Only) , Providing & Erecting 3 Pole Mccb, 415V, Up To 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb, 415V, 200A, Rated Short-Circuit Breaking Capacity25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magneticsetting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact.Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb 415V, 250A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu) Adjustable Thermal Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Providing & Erecting 3 Pole Mccb 415V, 630A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb (Material + Labour) , Supplying & Erecting On Load Change Over Switch 4 Pole, 415V, 200A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3 As Per Specification No. Sw-Swr/Cos. (Material + Labour) , Supplying, Erecting, Testing & Commisioning Static Energy Meter With 240V 50 Hz. Ac Supply 5 To 30 A, Accuracy Class 1.0 With Backlit Lcd Display, (Measuring And Display Kwh, Kvah,V, I, Pf, Frequency, Kw, Kva, Six Months History Of Energy & Md In Kw & Kva) With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weatherproof Pvc Wires Duly Tested By Electric Supply Company. , Providing Temporary Illumination Consisting Of White/Colour Series Lights With 8Mm Led Miniature L S Of 2 To 3.4V [1000 Nos] With Cap With Required Switchgears Erected And Dismantled With Rotor Effect As Approved With Scaffolding, Up To Three Days As Per Specification No. Te-Il/Srl (Material + Labour) , Supplying And Erecting Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Upto 16A To Use Independently Or In Conjunction With Contactor. (Material + Labour) , Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching On And Switching Off Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230V / 10A With 10 Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacity Contactors Timer Erected In Provided M.S. Box. (Material + Labour) , Supplying And Erecting Four Pole Power Contactor 430V, 40A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. (Material + Labour) , Supplying 12 V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged Complete With 36 Months Warranty Complete (Material Only) , Supplying, Erecting, Testing & Commisioning Of Required Size Electrolyte Copper Bus Patti Or Bar Tin Plated In Bus Bar Chamber/In Panel Or Any Other Purpose, Suitable For 500 Volt With Require Capacity Having Thermal Conductivity Of 400W Per Meter With Composition Pure Copper 99.9% Current Density 1.8 With Fixing Arrangement (Like Lug Or Bottle Type Lug) To Both The End With High Grade Polyolefin Insulation Sleeve Complete As Per Specification No. Cp-Bb (Material + Labour) , Supplying Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coil Suitable To Operate On 230V A.C. Supply Erected On Polished Double Wooden Block/Sunmica Block Of Suitable Size (Material Only) , Supplying Electronic Type Cordless Call Bell Erected On T.W. Board Having Portable Bell Push Working On 9V D.C. Battery And (Effective Range Upto 45 Meter) Bell On 250 V A.C. Supply. (Material Only) , Supplying 5W-7W, 230V Integral Type Led L Suitable For B-22/E-27 Base. (Material Only) Fg-Lp , Supplying 10-12W, 230V Integral Type Led L Suitable For B-22/E-27 Base. Fg-Lp , Supplying 18W, 230V Integral Type Led L Suitable For B-22/E-27 Base. Fg-Lp , Supplying & Erecting Integral Post Top Lantern Fixtures (Light House Type) Suitable Upto Led 18 W L Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole/ Bracket As Per Specification No. Fg-Odf/Ptl. (Material + Labour) , Supplying Pvc Surface Modular Double Mounting Plate 3 Modules Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 6 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 8 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 12 Module Complete. (Material Only) , Supplying Pvc Surface Modular Double Mounting Plate 16/18 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module Complete.(Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Complete. (Material Only) , Supplying Pvc Surface Modular Switch Box With Double Mounting Plate For 16/18 Module Complete. (Material Only) , Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E Class Insulation. (Material + Labour) , Making Trench In Soft Soil Having 0.75M Depth And Minimum 0.3M Width For Laying Provided Cables Up To Voltage Level Of 1.1Kv Complete As Per Specification No. Cw-Exn-Ctr , Supplying 6 To 32A, 10Ka, Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. (Material Only)
Contract Date: Ref. Documents Contract Value : 6.45 Lakh
Boards / Undertakings / PSU No of Bidders 4
Maharashtra View Result →
14.
Water Resources and Irrigation #11335994 Technical Bid
Tender for Repair To Pumping Machinery Of 5 Cusec Vt Pump Set Of Unit Iv Along With Extension Of Column Pipe And Other Allied Works At Lis Katal Batal. , The Job Involve Disconnecting The Electrical Connection Of Motor Of Unit Iv And Dismantling The Slip Ring Motor From The Ratchet Assembly By Way Of Decoupling The Required Coupling Nuts And Bolt. Lifting The Motor From Base Frame With The Help Of Existing Mono Rail And Chain Pulley Block, Then Keeping It Aside. Dismantling The Ratchet Assembly From The Discharge Head And Lifting It Aside. Dismantling The Delivery Line From The Discharge Head And Suction Column By Way Of Unscrewing The Required Nuts And Bolt. Lifting The Discharge Head And Keeping It Aide. Extracting Out The Column Suction Pipe, Line Shaft, Spider Guide One By One By Way Of Dismantling The Required Nut And Bolt And Unscrewing The Line Shaft From Each Socket, Then Finally Extracting Out The 2 Stage Vt Pump Of 5 Cusec Discharge, Head Load Carriage Of Pump, Line Shafts, Sleeves, Stuffing Box And Sockets Along With Discharge Head To Road Side Up To Loading Point With The Help Of Skilled Manual Labour And Then Loading Into A Mechanical Transport For Carrying To Work Shop For Repairs With The Help Of Crane/Tools, Tackles Using Manual Labour. Complete Job Includes Cost Of Labour, Carriage Charges And Hire Charges Of Tools And Tackles. Repair To Stuffing Box By Providing And Fitting Of New Bronze Bush As Per Sample To Required Size After Re Metalling, Finishing And Drilling Holes And Making Internal Threads On Stuffing Box As Per Requirement For Securing Studs. Repair To Top Shaft By Way Of Rebuilding With Machine Able Ss Electrode At Worn Out Portions And Then Threading And Making Key Way Of Required Size. Dismantling The 2 Stage Vt Pump By Way Of Cutting Of Rusted Bolts, Nuts And Studs And Separating The Discharge Bowl, Suction Bowl From Pump Body And Then Dismantling The Two Stage Pump To Extract The Damaged Impellers And Pump Shaft. Repairs To 05 Cusec Vt Pump By Way Of Providing/ Fitting Of Neck Ring Of Stainless Steel Material- 02 Nos. By Casting, Turning And Boring To The Required Size And Press Fitting The Same In The Pump Body Then Locking Properly. Repair To Pump Shaft By Way Of Welding Turning And Finishing To Required Size And Then Threading It And Making Of Key Way On Shaper To The Required Size. Repair To Ist And Iind Stage Impeller By Fabrication Of 1 No. Neck Ring Each For Impellers And Then Press Fitting It On The Impeller And Locking It Properly And Rebuilding The Worn Out Portion With Machine Able Ss Electrode And Turning, Machining It To Its Original Shape And Size. Repair To Stuffing Box By Providing And Fitting Of New Bronze Bush As Per Sample To Required Size After Metalling, Finishing And Drilling Holes And Making Internal Threads On Stuffing Box As Per Requirement. Repair To Top Shaft By Way Of Rebuilding With Machineable Ss Electrode At Worn Out Portions And Then Threading And Making Key Way On Shaper To The Required Size. Fabrication Of New Check Nut Of Given Size. Providing And Fitting Of New Ci Spider Guide 01 Nos. Along With Rubber Bush As Per Sample. Fabrication/ Providing And Fitting Of 04 Nos Pump Body Bushes. Repairs To 02Nos Line Shaft By Way Of Welding, Turning And Making Threads As Per Sample. Providing And Fitting Of 02 No Sleeve For Line Shaft By Making Internal Threads Of Required Size. providing and Fixing Of Rubber Sheet Joints For Flanges 05 Nos Cut To Required Size. The Job Includes Fitting Of The Pump Using New Nuts And Bolts/ Studs. Fabrication/ Providing And Fitting Of Well Mouth As Per Sample And Strainer To The Bell Mouth Of Pump Body.Connecting The Bottom Suction Pipe Piece With The Pump Body Along With Line Shaft With Socket And Required Nuts And Bolts And Rubber Sheet Joints Of Appropriate Size Then Lowering The Pump In The Sump Using Tools And Tackles With The Help Of Manual Labour And Existing Chain Pulley Arrangement. Connecting All The Suction Pieces With Required Nuts, Bolts And Rubber Sheet Joints, Line Shaft With Socket, Fixing Of Spider Guide On Line Shaft Ensuring That The Spider Guide Bush Remain At Center Of Sleeves.Fitting All The Suction Pipes, Line Shaft, And Spider Guide In Similar Manner. Fabrication/Providing And Fitting Of New Suction Column Of 10 Inch Dia Of 2.5Ft Approximately With Flange Welded To Its Ends Along With Line Shafts, Spider Guides, Sleeves And Socket If Required. The Flanges Should Have 2.5 Inch (Min) Collar Width And 16Mm Thickness. The Pipes Ends Should Have Been Faced To Accommodate The Spider Guide Accurately Without Any Play. The Ends Of Pipes Should Have 04 Nos Wedge Welded To Their Ends To Support/ Give Strength To Welded Flanges. Then Fitting The Additional Fabricated Pipe Piece Before Discharge Head On The Top Piece Of Suction Pipe With Required Nuts, Bolts And Rubber Sheet Joints, Fitting The Stuffing Box With Gland Set And Gland Packing, Fitting Of Ratchet Assembly, Then Assembling The Motor By Providing And Fitting Bushes Of Appropriate Sizes And With Existing Coupling Nuts, Bolts. Giving All The Electric Connection And Testing The Running Of Pump On Full Load And Checking Of Any Type Of Leakage At Suction Column Joints.Complete Job Includes Cost Of Material, Hire Charges Of Tools And Tackles Required For Execution Of Job, Carriage, Transportation, Labour Charges And Testing Complete At Lis Katalbatal. Material Of Construction Should Be As Below:- I Line Shaft/ Line Shafts Sleeves :- Stainless Steel (Aisi-410) Ii Column Pipes Complete As Per Site Condition. :- Steel As Per Is: 210 Of 1978/Grade A Of Is:2062 1984 With Latest Amendments And Is: 4270 Iii Nuts And Bolts :- High Tensile Steel Iv Line Shaft Coupling :- Steel As Peris1030 Of 1982 With Latest Amendment V Other Component :- Conforming To Is 1710 With Latest Amendments For Such Duty, Head Variations And Quality Of Raw Water Vi Thickness Of Pipe :- 08Mm Dismantling The 120 Hp Oil Immersed Star Delta Starter From Installed Position Of Pumping Unit No. Iv After Disconnecting All Electrical Connections From Input And Output Side. Loading In Transport For Carriage To Workshop For Repair. Repair To Starter By Way Of Extracting Out The Damaged Copper Contact Points Both Moving And Fixed, Thimbles, No Volt Coil, Tripping System, Overload Relay And Replacing The Same With New Ones, Repairs To Operating Mechanism. Providing/Filling Of 20 Liters Transformer Oil For Topping Of Starter After De-Moisturizing The Existing Oil. Back Carriage Of The Starters To Lis. Installation Of Starter By Proving And Fitting New Nuts And Bolts Required Commissioning And Test. Giving All The Electric Connection By providing and Fixing New Thimbles Of Appropriating Rating/Size. Note: The Bidders Are Advised To Visit The Site And Quote The Rates Including The Rebate On Old Material. Any Modification/Alternation If Needed At The Time Of Execution Of Job Shall Be Carried Out At Site Accordingly , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
15.
Agriculture #11328645 AOC
Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Duvcon,Indosaw Moisture Meter; Duvcon,Indosaw; Annual Maintenance Contract (Amc); Quarterly; Yes - Maintenance Service/ Repair Of Moisture Metre (Mm) , Repair Of Mm Printer , Repair Of Power Adapter Of Mm (9V) , Repair Of Power Adapter Of Mm Printer (5V) , Repair Of Mm Printer Data Cable (Rs 232) , Repair Of Operating/ Ratchet Handle , 74148 , 1-K , 10K Present , 14 Pin Dip Ic Holder , 16 Pin Dip Holder , 203, 105, 502, 503 Tre Ot , 22 Ohm , 25 V, 10 Uf , 25V, 100 Uf , 25V, 470 Uf , 28 Pin Dip Holder , 4.7 K Network Resistance , 40 Pin Handle , 40 Pin Header Set , 40 Pin Male Header , 470 Ohm 1% Tolerance , 5V Dpdt , Atmega 328P Set , Base Plate Complete , Battery Compartment , Bell Switch , Beveal Gear , Bevel Pin , Bevel Pinion , Bottom Plunger , Bracket , Buzzer , Carrier Handle , Com. Meggar Box , Complete Pcb With Printer Facility , Complete Sticker (Duvcon) , Complete Sticker (Indosaw) , Connector Lead 12 Pins , Connector Lead 2/3 Pins , Crystal 6.144 Mhz , Dc Socket/ Phono Socket , Electronic Switch , Eprom , F.N.D. Board , Guide Nut , Ic 146818A , Ic 4051 , Ic 7135 , Ic 74373 , Ic 7447 , Ic 7448 , Ic 7600 , Ic 7660 , Ic 7805/ Ic Regulator 7805 , Ic Base 16 Pins , Ic Base 20 Pin , Ic Base 28 Pins , Ic Base 8 Pin , Insulation Disc , Keypad (Duvcon) , Keypad (Indosaw) , Keypad Duvcon , Lcd/ Led/ Pcb Display , Lead Screw , Max 232 , Max 8031/ Micro Controller , Mm Body (Duvcon) , Mm Body (Indowsaw) , Module Cell For Date & Time , Pcb Press Switch , Pinion Bush , Pointer , Pre Volt Circuit Set , Pressue Plate , Printer Ic , Printer Port , Relay , Rice Module , S 9014 , S9014 , Spur Gear , Spur Gear Axle , Spur Pinion , Switching Transistor (Bc 107) , Temprature Sensor , Test Cup , Test Cup Handle , Thrust Bearing , Timer Ic 7555 , Transformer , Trimpot 1M, 5K, 20 K Or 50 K , Volume Cup A , Volume Cup B , Volume Cup C , Wire 1.25 , Wooden Base , Lcd Controller , Display Ic , Ratchet Handle , Supply Set , Cell Leak Proof 1.5V , Oil & Greasing , Ic 7400 , Funnel Strip , Complete Gear Set , Electronic Led Card , Ad Converter
Contract Date: Ref. Documents Contract Value : 10,693
Boards / Undertakings / PSU No of Bidders 3
18.
Civil Aviation #11313210 Technical Bid
Tender for Procurement And Supply Of Aircraft Special Tools / Equipment, Spares Etc. On One Time Requirement Basis With The Type Of Aircraft In Use , Ifr 4000 , Ifr 6000 , 406 Mhz Elt Annual Inspection Kit , Pitot Static Leak Tester , Master Landing Compass , Battery Capacity Tester , Battery Charger , Main Landing Wheel (C 142.5000-16.00) , Nose Landing Wheel (C 142.5000-17.00) , Main Tank Closure (L 143.7231-01.00) , Float Device L.H (L 143.7231-08.00A) , Float Device L.H (L 143.7231-08.00B) , Float Device R.H L (143.7241-08.00A) , Float Device R.H L (L143.7241-08.00B) , Sealing (Z 42.7231-01.21) , Ring (155N-607-9,6) , Sealing (Z 42.7231-00.41) , Cylindrical Spring Washer (Ln-0365) , Shortened Screw (C-142.8211-00.33) , Shortened Screw (C-142.8211-00.32) , Screw (L-242.8233-00.27) , Screw (L-242.8233-00.30) , Screw (Z-42.8210-00.27) , Sealing (Z-143.1500-22.00) , Lock Bolt (Bn 0643 1050 008) , Float Device (L 143.7231-07.00 ) , Float Device (L 143.7231-07.00A) , Nose Landing Gear Installation (C142.5210-00.00) , Disk Brake Complete (K 22-1200-7) , Starter (Mhb-4016) , Magneto (Right) (6350) , Magneto (Left) (6351) , Fuel Pump/Motor Assembly (A8150-B1) , Airspeed Indicator (1107.42-8) , Va Meter (Lun 2744.03) , Clock Astrotech (Lc-2 At420100) , Artificial Horizon (Lun1241a8g8w) , Turn And Bank Indicator (1394T100-14Rb) , Rpm Indicator (Lun1301.02) , Manifold Pressure Indicator (Lun1401.55-8) , Fuel Quantity Indicator (Lun1639.72) , Four Pointer Engine Indicator (Lun 1639.59) , Disk Brake Complete (K22-1200-7) , Brake Control From Left Seat (L143.5310-00) , Oil Filter (Ch48111-1) , Air Filter (Ba 105) , Relay (Tke52 Pdt) , Pitot Static Tester (1811D-605) , Relay (Tke 52 Pdt) , Relay (Tke 52) , Circuit Breaker (1110-F112-P1m1-1A) , Circuit Breaker (1110-F112-P1m1-2A ) , Circuit Breaker (1110-F112-P1m1-3A) , Circuit Breaker (1110-F112-P1m1-4A) , Circuit Breaker (1110-F112-P1m1-6A) , Aircraft Battery (G-246) , Ignition Harness (L 67U20609) , Ignition Harness (R 67U20608) , Spark Plug (Rem 38E) , Spark Plug (297656) , Fuel Difference Pressure Indicator (831147) , Air Filter (825.750) , Oil Filter (825016) , Master Cylinder /Handbrake Lever (830196) , Fuel Filters (830566) , Main Wheel Tire (830072) , Main Wheel Complete (830070) , Nose Wheel Assy (832449) , Nose Wheel Tire (830083) , Lh Door Kit (1215201 Contains Cover Plate Left P/N 1215210071) , Rh Door Kit (1215202 Contains Cover Plate Right P/N 1215210061) , Drive Mechanism Bell Crank (Pipistrel P/N 1181065) , Hex Self-Locking Nut (Pipistrel P/N5011053) , Loctite 243-Thread Locking Compound (Pipistrel P/N 5091023) , Air Brake Moment Measurement Kit -Special Tool (Pipistrel P/N 1190459) , Torque Stripe Paint , Nose Wheel Inner Tube (5051003) , Nose Wheel Tire Tost (5050036) , Main Wheel Tube (5051002) , Brake Disc (1140003) , Brake Pad (1140028) , O-Ring (5057028) , O-Ring (5057026) , Brake Pad And Disc Kit (1140124) , Brake Cylinder (1140017) , Brake Cylinder (1140019) , Deep Groove Ball Bearings (5080022)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
19.
Educational and Research Institute #11308091 AOC
Tender for Purchase Of Fpga Board For Vlsi Lab , Xc6slx16 Based On Xilinx Spartan-6 Fpga Features 14579 Logic Cells 136 Kb Of Block Ram 2 Nos Of Clock Management Tiles(Cmt) 2 Nos Of Memory Controller Block(Mcb) 186 User Installation Of Lines 2278 Kb Of Distributed Ram 32 Nos Of Dsp Slices 16 Nos Of Digital Input Using Slide Switches With Led Indication 16 Nos Of Digital Output Using Discrete Leds 16 2 Lcd Is Provided For Display The Text Message One Reset Switch One Switch For Giving Manual Clock Fpga Configuration Through On Board Xilinx Usb To Jtag Programmer With Isolation To Configure Fpga On Board Flash Prom Xcf04s(Programmable Through Usb To Jtag Programmer) Total 186 Installation Of Pins: 100 Pins Used For Integrating Peripheral Like Led , Switches Etc., Balance Pins Are Available To User In 3 Nos Of 20 Pin Header 1 No Of 26 Pin Headers To Interface Vlim Cards Like Traffic Light Controller / On - Board Tlc Factory Settable On Board Programmable Pll Oscillator From 1Mhz To 100 Mhz Using Jumpers 4 Nos Of 7 Segment Led Display One Relay And Buzzer Provided Stepper & Dc Motor Drive Provided On Board(Motor Optional) 4*4 Matrix Key Provided On Board I2c Rtc Interface On Board Temperature Sensor Interface Spi Based Analog To Digital Converter Resolution:12 Bits Number Of Channel: 2 Channel Input Range: 0 To 3.3V Speed:1 Msps Spi Based Digital To Analog Converter Resolution:12 Bits Number Of Channel: 2 Channel Input Range: 0 To 3.3V Speed: 8.5Μs Setting Time Adc Inputs And Dac Outputs Are Terminated At J801 Connector Housed In A Sleek Plastic Cabinet With Built In Smps 5V / 2A Compatible With Xilinx Ise Web Pack Software ( Version 12.1 And Above) 12V Dc Motor 0.5Kg Stepper Motor , Purchase Of Fpga Board For Vlsi Lab , Xc6slx16 Based On Xilinx Spartan-6 Fpga Features 14579 Logic Cells 136 Kb Of Block Ram 2 Nos Of Clock Management Tiles(Cmt) 2 Nos Of Memory Controller Block(Mcb) 186 User Installation Of Lines 2278 Kb Of Distributed Ram 32 Nos Of Dsp Slices 16 Nos Of Digital Input Using Slide Switches With Led Indication 16 Nos Of Digital Output Using Discrete Leds 16 2 Lcd Is Provided For Display The Text Message One Reset Switch One Switch For Giving Manual Clock Fpga Configuration Through On Board Xilinx Usb To Jtag Programmer With Isolation To Configure Fpga On Board Flash Prom Xcf04s(Programmable Through Usb To Jtag Programmer) Total 186 Installation Of Pins: 100 Pins Used For Integrating Peripheral Like Led , Switches Etc., Balance Pins Are Available To User In 3 Nos Of 20 Pin Header 1 No Of 26 Pin Headers To Interface Vlim Cards Like Traffic Light Controller / On - Board Tlc Factory Settable On Board Programmable Pll Oscillator From 1Mhz To 100 Mhz Using Jumpers 4 Nos Of 7 Segment Led Display One Relay And Buzzer Provided Stepper & Dc Motor Drive Provided On Board(Motor Optional) 4*4 Matrix Key Provided On Board I2c Rtc Interface On Board Temperature Sensor Interface Spi Based Analog To Digital Converter Resolution:12 Bits Number Of Channel: 2 Channel Input Range: 0 To 3.3V Speed:1 Msps Spi Based Digital To Analog Converter Resolution:12 Bits Number Of Channel: 2 Channel Input Range: 0 To 3.3V Speed: 8.5Μs Setting Time Adc Inputs And Dac Outputs Are Terminated At J801 Connector Housed In A Sleek Plastic Cabinet With Built In Smps 5V / 2A Compatible With Xilinx Ise Web Pack Software ( Version 12.1 And Above) 12V Dc Motor 0.5Kg Stepper Motor
Contract Date: Jun 25, 2026 Contract Value : 73,160
Statutory Bodies & Commissions/Committees No of Bidders 3
20.
Railways #11305529 AOC
Supply Of Procurement Of Bpac/Ufsbiprocurement Of Bpac/Ufsbi,Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply Of Complete Set Of Block Proving Axle Counter Using Ufsbi For Single Line As Per Irs;S- 105/2012(Ver-0) Or Latest Consisting Of (A) Block Panel As Per Rdso Drg No. Rdso/S/32019=2N O.(B) Wired Relay Rack Consisting Of Rdso Approved & Pre Inspected Ufsbi And Rdso Approved & Pre I Nspected Relays With Bases As Per Rdso Drg No. Rdso/S/32020=2No.(C)Block Telephone As Per Rdso Drg No. Rdso/Spn/191/2006=02No.(D) Universal Fail Safe Block Interface=02 No. With Media Changeov Er [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Sse/C/Signal/Jallandhar Punjab 2.00 Set , Block Panel Bpac (Block Proving With Digital Axle Counter) Using Ufsbi Double Line Co Mplete Description As Per Anexxure Attached [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Page 1 Of 14 Run Date/Time: 01/12/2025 15:39:49Stores/Northern Rly Tender Document , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest With Latest Amendment. Complete Description As Per Annexxure Attached. [ Warrant Y Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing, Commissioning Of Block Proving With Axle Counter Using Bl Ock Panel And Ufsbi For Double Line Operation As Per Rdso Specification No.Irs:S-105/2012 (Ver.0) Or L Atest With Latest Amendment. Complete Description As Per Annexxure Attached. [ Warranty P Eriod: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing, And Commissioning (As The Case May Be) Of Block Proving B Y Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Spec No. Irs: S-105/2012 [Ver.0] With Latest Amendment. Each Set Consisting Of Following: (I) Universal Fail Safe Block Interface C Omplete With All Accessories As Per Spec No. Irs: S-104/2012 [Ver.0] With Latest Version And Amendme Nt. Qty-02 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drg No. Rdso/S/32017 For D Ouble Line ( With Latest Amdt.)- Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement A S Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg No. Rdso/S/32018 With Latest Amdt. And Supply Of All Type Of Relays (Iv) Block Telephone With Accesso Ries As Per Rdso Spec No. Rdso/Spn/191/2006, Qty-2 Nos. With All Type Lighting Protection And Inbuilt Automatic Media Change Over Of Modems Working On Redundant Channel For Data Transmission On Ofc/ Quad-1 Pair And Secondary Modem For Ufsbi For Use With Secondary Media Ofc/Quad-1 Pair. Or Suppl Y, Installation, Testing, And Commissioning (As The Case May Be) Of Microprocessor Based Station Maste R Block Panel For Double Line Block Instrument With Block Telephones As Per Rdso/Spn/175/2005 With Automatic Media Change Over Material And Description: - (I) Microprocessor Based Station Master Bloc K Panel For Double Line Instrument With Block Telephone As Per Rdso/Spn/175/2005- Version 1 Or Lates T (B) Block Telephone As Per Rdso Spec No.Rdso/Spn/191/2005 Or Latest (Inspection By Rdso)- Qty-2 Nos. (Ii) Supply Of Microprocessor Based Ssbpac (D) Block Instrument For Double Line As Per Rdso/Spn/ 175/2005 Version 1 Or Latest Qty-2 Nos (Iii) Supply Of Lighting And Surge Protection Devices Or Power Lin E 24 V Dc, Class-C Qty-02 Nos (Iv) Supply Of Lighting And Surge Protection Devices For Data Lines Class D Qty. 2 Nos. (V) Supply Of All Type Of Relays For Double Line (Vi) Auto Communication Change Over Units Working On Redundant Channel For Data Transmission On Ofc/Quad-1 Pair And Secondary Modem For Us E With Secondary Media Ofc/Quad-1 Pair. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver.1. 0) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interf Ace Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S/320 17 For Double Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32018 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Teleph One With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type Of Lig Hting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem For Bpac Usi Ng Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 2.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver.1. 0) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interf Ace Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S/320 17 For Double Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32018 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Teleph One With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type Of Lig Hting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem For Bpac Usi Ng Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 2.00 Set , Supply, Installation And Commissioning Of Block Proving By Axle Counter Using Block Pan El And Ufsbi For Double Line Operation As Per Rdso Specification No.Irs:S-105/2012 (Ver.0) With Latest Amendment. Each Set Consisting Of Following; (I) Universal Fail Safe Block Interface Complete With All A Ccessories As Per Spec. Irs:S-104/2012(Ver.0) With Latest Version And Amendment Qty-2 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drawing No. Rdso/S/32019 For Double Line (With Lates T Amendment).-Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg .No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. No. Rdso/S/32 020 With Latest Amendment And Supply Of All Type Of Relays (Iv) Block Telephone With Accessories As Pe R Rdso Spec. No. Rdso/Spn/191/2006. Qty-2 No. With All Type Lighting Protection Or (B) Supply, Install Ation, Testing, Execution And Commissioning Of Microprocessor Based Station Master Block Panel For Do Uble Line Block Instrument With Block Telephones As Per Rdso/Spn/175/2005 And Description: (1) Supp Ly Of (A) Microprocessor Based Station Master Block Panel For Double Line Instrument With Block Telepho Nes As Per Rdso/Spn/175/2005- Version 1 Or Latest (B) Block Telephone As Per Rdso Specification No. Rdso/Spn/191/2005 Or Latest (Inspection By Rdso)- Qty. 2 Nos (2) Supply Of Microprocessor Based Ss Bpac Block Instrument For Double Line As Per Rdso/Spn/175/2005 Version 1 Or Latest (Inspection By Rd So) Qty 2 Nos. (3) Supply Of Lighting And Surge Protection Devices Or Power Line 24V Dc, Class-C Qty. 2 Nos. (4) Supply Of Lighting And Surge Protection Devices For Data Lines Class-D Qty. 2 Nos. (5) Supply Of All Type Of Relays For Double Line [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Er (Sig)/Jrc, Punjab 2.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver 1.0 ) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interface Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S /32019 For Single Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sea Ling Arrangement As Per Rdso Drg No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32020 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Tel Ephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type O F Lighting Protection (V) Supply Of Of Automatic Media Changeover Along With Additional Modem For Bpa C Using Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 1.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver 1.0 ) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interface Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S /32019 For Single Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sea Ling Arrangement As Per Rdso Drg No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32020 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Tel Ephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type O F Lighting Protection (V) Supply Of Of Automatic Media Changeover Along With Additional Modem For Bpa C Using Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 5.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver 1.0 ) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interface Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S /32019 For Single Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sea Ling Arrangement As Per Rdso Drg No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32020 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Tel Ephone With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type O F Lighting Protection (V) Supply Of Of Automatic Media Changeover Along With Additional Modem For Bpa C Using Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Senior Section Delhi 1.00 Set , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Rdso Specification No. Irs:S-105/2012 ( Ver.0) Or Latest Complete Description As Per Annexxure Attached. [ Warranty Period: 30 Months Aft Er The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing & Commissioning Of Block Proving With Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No. Irs:S-105/2025 ( Ver.1. 0) Or Latest With Latest Amendment Each Set Consisting Of Following: (1) Universal Fail Safe Block Interf Ace Complete With All Accessories As Per Specification Irs-S-104/2012 ( Ver.0) With Latest Version And Amendments Qty. 2 Nos Ii.Block Panel Complete With All Accessories As Per Rdso Drg. No. Rdso/S/320 17 For Double Line ( With Latest Amendments ) Qty. 02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg No. Rdso/S/32018 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. Rdso/S/32018 With Latest Amendment And Supply Of All Types Of Relays (Iv) Block Teleph One With Accessories As Per Rdso Specification No. Rdso/Spn/191/2005 Qty-02 Nos With All Type Of Lig Hting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem For Bpac Usi Ng Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Page 5 Of 14 Run Date/Time: 01/12/2025 15:39:49Stores/Northern Rly Tender Document , Supply, Installation, Testing And Commissioning (As The Case May Be) Of Block Proving By Axle Counter Using Block Panel And Ufsbi For Single Line Operation As Per Spec. No.Irs: S105/2012 [Ve R.0] With Latest Amendment. Each Set Consisting Of Following: (I) Universal Fail Safe Block Interface Com Plete With All Accessories As Per Spec No. Irs: S-104/2012 [Ver.0] With Latest Version And Amdt. Qty-0 2 Nos. (Ii) Block Panel Complete With Accessories As Per Rdso Drg. No.Rdso/S/32019 For Single Line (W Ith Latest Amdt.)-Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Dr G.No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg. No. Rdso/S/3 2020 With Latest Amendment And Supply Of All Type Of Relays (Iv) Block Telephone With Accessories As P Er Rdso Spec.No.Rdso/Spn/191/2006, Qty-2 Nos. With All Type Lighting Protection. (V) Automatic Media Changeover Of Modems Working On Redundant Channels For Data Transmission On Ofc/Quad-1 Pair And Secondary Modem For Ufsbi For Use With Secondary Media Ofc/Quad-1 Pair. Or Supply, Installation, Te Sting & Commissioning (As The Case May Be) Of Microprocessor Based Station Master Block Panel For Si Ngle Line Block Instrument With Block Telephone As Per Rdso/Spn/175/2005 And Description: (I) Microp Rocessor Based Station Master Block Panel For Single Line Instrument With Block Telephone As Per Rdso /Spn/175/2005- Version 1 Or Latest (B) Block Telephone As Per Rdso Spec No. Rdso/Spn/191/2005 Or L Atest (Insp. By Rdso)-Qty-2 Nos. (Ii) Microprocessor Based Ssbpac (D) Block Instrument For Single Lines Per Rdso/Spn/175/2005 Version 1 Or Latest (Insp. By Rdso) Qty-2 Nos (Iii) Lighting And Surge Protectio N Devices Or Power Line 24 V Dc, Class-C Qty-02 Nos (Iv) Lighting And Surge Protection Devices For Data Lines Class D Qty. 2 Nos. (V) Supply Of All Type Of Relays For Single Line (Vi) Auto Communication Chang Eover Units Working On Redundant Channels For Data Transmission On Ofc/Quad-A Pair And Secondary Modem For Use With Secondary Media Ofc/Quad-1 Pair. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing, Commissioning Of Block Proving With Axle Counter Using Bl Ock Panel And Ufsbi For Single Line Operation As Per Rdso Specification No.Irs:S-105/2012 (Ver.0) Or La Test With Latest Amendment. Each Set Consisting Of Following; (I) Universal Fail Safe Block Interface Co Mplete With All Accessories As Per Spec. Irs:S-104/2012(Ver.0) With Latest Version And Amendment Qty -2 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drawing No. Rdso/S/32019 For Singl E Line (With Latest Amendment).- Qty-02 Nos. (Iii) Relay Rack With Due Locking And Sealing Arrangement As Per Rdso Drg.No. Rdso/S/32020 Including All Relays And Wiring As Wiring Diagram As Per Rdso Drg . 6No. Rdso/S/32020 With Latest Amendment And Supply Of All Type Of Relays (Iv) Block Telephone With Accessories As Per Rdso Spec. No. Rdso/Spn/191/2006 Qty-2 No. With All Type Lighting Protection (V) Supply Of Automatic Media Changeover Along With Additional Modem As Per Manufacturers Specificati On For Bpac Using Ufsbi. This Includes Transportation Of Material From Consignee Store To Site Of Work. Or Supply, Installation, Testing And Commissioning (As The Case May Be) Of Microprocessor Based Stati On Master Block Panel For Single Line Block Instrument With Block Telephones As Per Rdso/ Spn / 175/2 005 And Description: (1) Microprocessor Based Station Master Block Panel For Single Line Instrument Wit H Block Telephones As Per Rdso/Spn/175/2005- Version 1 Or Latest (B) Block Telephone As Per Rdso Sp Ecification No. Rdso/Spn/191/2005 Or Latest-Qty. -2 Nos (8) Microprocessor Based Ssbpac (D) Black In Strument For Single Line As Per Rdso/Spn/175/2005 Version 1 Or Latest Qty 2 Nos. (Iii) Lightening And S Urge Protection Devices For Power Line 24V Dc, Class-C Qty. 2 Nos. (Iv) Lightening And Surge Protection Devices For Data Lines Class-D Qty. 2 Nos. (V) Supply Of All Type Of Relays For Single Line (Vi) Auto Comm Unication Changeover Units Working On Redundant Channels For Data Transmission On Ofc/Quad-1 Pair And Secondary Modern For Use With Secondary Media Ofc/Quad-1 Pair. [ Warranty Period: 30 Month S After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply, Installation, Testing And Commissioning (As The Case May Be) Of Block Proving By Axle Counter Using Block Panel And Ufsbi For Double Line Operation As Per Rdso Specification No . Irs: S-105/2012 (Ver.0) With Latest Amendment. Each Set Consisting Of Following; (I) Universal Fail Safe Bloc K Interface Complete With All Accessories As Per Sepc. Irs:S-104/2012 (Ver.0) With Attest Version And A Mendment Qty-2 Nos. (Ii) Block Panel Complete With All Accessories As Per Rdso Drawing No. Rdso/S/ 32017 For Double Line (With Latest Amendment).- Qty-02Nos. (Iii) Relay Rack With Die Locking And Sealing Arrangement As Per Rsso Drg.No. Rdso/S/32018 With Latest Amendment And Supplu Of All Type Of Rela Ys (Iv) Block Telephone With Accessories As Per Rdso Spec. No. Rdso/Spn/191/2006. Qty ? 02 No. With All Type Lighting Protection. (V) Automatic Media Changeover Of Modems Working On Redundant Channe Ls For Data Transmission On Ofc/ Quad-1 Pair And Secondary Modem For Ufsbi For Use With Secondary Media Ofc/Quad-1 Pair. Or Supply, Installation, Testing And Commissioning (As The Case May Be ) Of M Icroprocessor Based Station Master Block Panel For Double Line Block Instrument With Block Telephones As Per Rdso/ Spn/175/2005 And Description: (I) Microprocessor Based Station Master Block Panel For D Ouble Line Instrument With Block Telephones As Per Rdso/Spn/175/2005- Version 1 Or Latest (B) Block T Elephone As Per Rdso Specification No. Rdso/Spn/191/2005 Or Latest ? Qty-2 Nos. (Ii) Microprocessor Based Ssbpac (D) Block Instrument For Double Line As Per Rdso /Spn/175/2005 Version 1 Or Latest ? Qt Y 2 Nos. (Iii) Lightening And Surge Protection Devices For Power Line 24V Dc, Class-C Qty. 2 Nos. (Iv) Lig Htening And Surge Protection Devices Data Lines Class- D Qty. 2 Nos. (V) Supply Of All Type Of Relays? For Double Line (Vi) Auto Communication Changeover Units Working On Redundant Channels For Data Transmi Ssion On Ofc/Quad-1 Pair And Secondary Modem For Use With Secondary Media Ofc/Quad-1 Pair. [ Wa Rranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Sr Section Engineer/Sig- Punjab 2.00 Set
Contract Date: Jun 18, 2026 Contract Value : 2.41 Crore
Government Departments No of Bidders 1
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
22.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
23.
Water Resources and Irrigation #11293228 AOC
Periodical and Emergent electrical maintenance under jurisdiction of Khatra Electrical and Water supply section during the year of 2025-26.- 1 Emergent Electrical maintenance work as & when required basis under the jurisdiction of Khatra Electrical & Water supply section i.e. KMD office, KC-II Div, Raipur Sub-div, Khalashi Shed, Kangsabati Upper and lower colony etc. under the jurisdiction of KMD. 2 a) Electrican 3 b)Helper for Electrician 4 Periodical and Emergent electricial maintenance work and pump operation for one year under jurisdiction of Khatra Electrical and Water supply section Khatra Electrical & Water supply section i.e. KMD office, KC-II Div, Kangsabati Upper and lower colony etc. 5 a) Electrican 6 b)Helper for Electrician 7 Opening the Ceiling fan testing, checking and Re-winding by supplying super enamelled copper wire of appropriate gauge, minilex paper, mica sheet, changing the loops, overhauling, backing, varnishing, re-fitting and using and measuring r.p.m. for ceiling fan above 36 sweep up to 60 sweep. 8 Supplying following sizes Capacitor of 250V rating: 2.5 MFD Capacitor (Universal Make or equivalent). 9 Supply Philips LED tube, model no : Mas LEDtube 1200mm 18W865 T8 I - 2100lm, 10 Supply of 2X20 T8 tube holder alongwith2 nos. 20 Watt T8 LED Tubes Specification T8 LED Tube , CCT-6500K, Lumen-2200, Make-Magik/ any, approved make. 11 Supply and fixing of smart bright essential street light complete with all accessories to be fixed / projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 72 watt with Toughend glass , 130 lm/w, Spd 15 kva at least and 5 years warrenty etc, Surya/ Crompton make. 12 Supply of Havells make, NU Bulb Plus 9W 865 B22 3 Star, 13 Supply of 6.0 sqmm FR stranded Copper wire, polycab/ Mescab /finolex, 14 Supply of 1.5 sq.mm FR stranded Copper Wire, Polycab/Mescab/finolex . 15 Supply of 5 A, piano key type Switch , Anchor/ havells . 16 Supply 5 A, 3 pin Piano flush type Socket Anchor/ havells. 17 Supply of Step Type Electronics Fan regulator, Anchor/ havells . 18 Supply of 16A kit kat rewireable fuse, havells/ standerd/ flora. 19 Supply of ammeter selector switch Current in Each phasewith OFF, 4 Pos. 90° angle of throw (OFF-R-Y-B). 20 Supply of voltmeter selector switch Votage between phaseswith OFF, 4 Pos. 90° angle of throw (OFF-RY-YB-BR). 21 Supply of 22.5 mm Hole Dia Mushroom Type Push Button. 22 Supply of 22.5 mm dia LED indicating lamps (red,yellow, blue) 23 Supply of 240VAC analog time switch for ON-OFF control of street light, L&t/Legrand make. 24 Supply of 3 pole power contactor type ML 2, 40A current rating , L&t/Legrand make. 25 Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 225mm sweep RPM 9001 1400(9) , EPC/Crompton make. 26 Opening the following Exhaust fan (1 Phase/3 Phase) /Stand Fan/Cabin Fan testing, checking, Re-winding by supplyingsuper enamelled copper wire of appropriate gauge, minalex paper, mica sheet, changing the loops, overhauling, becking, varnishing, re-fitting and testing and measuring r.p.m. etc.Cabin Fan (16 or 40 em, dia sweep), 27 Properly checking of the motor ( upto 75 HP), testing of developed IR value, load current factor, terminal lead joints, terminal bar etc. necessary repairing works. 28 Supplying of approved make high speed ceiling fan (ISImarked) of following sizes having double ball bearingcomplete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts 1200mm, Usha make. 29 Supply and delivery of direct on line ( DOL) strater panel board conforming to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+10%) AC, single phase, 50HZ(+5yo) comprising of ammeter, voltmeter, thermal overload relay,2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with l/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:- 1.5 H.P. (Relay Range 9-14 Amp.) 30 Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 200A, L&T make.
Contract Date: Aug 11, 2025 Contract Value : 9.66 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
26.
Defence #11286957 Technical Bid
Tender for Sch A Part- I To Ix: Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated As Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Dg Set) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (External Water Supply) , Total Amount Of Sch A Part-Ix (External Electric Supply) , Schedule A Part-X (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva Complete All As Specified And As Directed By Engr-In- Charge. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard/ Volina , Supply, Install, Testing And Commissioning Of Silent Diesel Engine Generating Set, 100 Kva/80 Kw, 1500 Rpm, 3 Phase, 415 V, 50 Hz, Power Supply Alternator Along With Fuel Tank, Control Panel., Battery And Complete Set Installed In Sound Acoustic Enclosure And Standard Accessories And Fittings With Power Factor 0.8, Plain Cement Concrete Foundation Suitable For The Generator Set As Per Manufacturers Instructions Complete With Standard Accessories And Microprocessor Based Integrated Dg Set Controller With Coupled To Alternator Rated At 100Kva/80 Kw At 415 Volts, Set Mounted On Channel Iron Base Frame Complete With Sub-Base With Batteries, Avm Pads And Std Panel All As Per Guideline Of Latest Cpcb Iv+ Norms All As Specified And Directed And Comprising Of The Following: , Note For Item No. 11.30 (I) Engine: Engine With Direct Injection, Water Cooled, 3 Cylinders, In-Line,4 Strokes Rated At Developing 126.8 Bhp @ 1500 Rpm For Continuous Duty Of Suitable For 100 Kva Alternator With Provision Of 10% Over Load For One Hour In Every 12 Hour Running Confirming To Bs 5514/ Iso 3046 Standard Totally Enclosed As Per Oem Specification And Directed By Engr-In-Charge. The Engine Has The Following Specification:- A) Mechanical Fip B) Mechanical Governor C) Turbocharger, Exhaust Manifold, Stainless Steel Exhaust Flexible Connection D) Radiator Cooled, With After Cooled E) Plate Type Lube Oil Cooler F) Filters G) Lube Oil H) Dry Type Replaceable Paper Element Air Cleaner J) Flywheel Housing And Flywheel To Suit Single Bearing Alternator K) Starting Motor-Electric, Battery Charging Alternator L) First Fill Lube Oil And Coolant (Ii) Alternator: Brushless Alternator, Self -Excited, Self -Regulated, Floor Mounted With All And / Or Roller Bearings, Statically And Dynamically Balanced Screen Protected Acoustic Enclosure Confirming To Is 4722 / Is 13364, Ip-23 Protection With H Class Insulation Limited Temperature Rise Of Class H, Automatic Voltage Regulator From No Load To Full Load, Ammeter Capacity Of Delivery 100 Kva, 415 Volts, 3 Phase, 50 Hz And Lagging For Ac Supply And Will Be Suitable For Tropical Conditions All As Per Oem And Directed By Engr-In-Charge. (Iii) Instrument Panel : Engine Instrument Panel Consisting Of On/Off Starting Switch With Key Lubricating Oil Pressure Gauge, Water Temperature Gauge, Battery Charging Indicating Lamp, Hour Meter With Rpm Indicator, Safety Control Against High Temperature Of Water, Over Speed Stop With Double Driver Adopter As Per Oem Specification And Directed By Enge-In-Charge. (Iv) Other Fittings: (A) Battery Charger : Battery Charger Having Electric Circuit Consisting Of Rectifiers, Capacitors And Resistance Etc. The Battery Charger Should Be Able To Charge 12 Volts 88 Ah Battery At A Time (V) Dg Set Shall Be Supplied Along With Acoustic Original Enclosure Of The Manufactures Suitable For 100 Kva Dg Set And All Connecting Accessories As Per Latest Cpcb Iv+ Norms , (Vi) The Diesel Oil, Lub Oil Etc. For Smooth Functioning Of Dg Set During Ph-I & Ph-Il Complete Testing And Full Tank Filing Of Diesel Oil After Ph-I & Ph-Ii Testing, Topping Of Lub Oil Etc. Required For Commissioning And Testing Of Dg Set. (Vii) Amf Panel: - Supply Installing Commissioning & Testing In Microprocessor Based Amf Panel Board Factory Made, Out Door Type Ip-65, Cubical Type, Vermin Proof, Dust Proof, Water Proof Made Out Of 3.15 Mm Thick Crca Sheet And Angle Iron Frame Of Size 50X50x6 Mm Inside Depth Not Less Than 50 Cm And Size Suitable To Accommodate The Following Accessories With Insulated Tpn Copper Busbar Of Rating Not Less Than 1.5 Times The Rated Capacity Of The Incomer Mccb Suitable For 100Kva Dg Set. Hinged Door With Locking Arrangement Duly Painted With Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Both Internally And Externally And Connecting With Cable With Lugs Including Internal Wiring With Copper Cable Of Suitable Size Using Lugs Compressing The Following Accessories All As Directed. (Notes : The Rate Quoted Shall Include For Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ) And Copper Bus Bar 240 Amps Duly Colour Sleeved Mounted On Epoxy Insulators-01 Set. Note:(I) Amf Panel Suitable For 100 Kva Dg Set To Connect With Grid Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. The Amf Panel Has The Following Specification:- A) 160A, 4 Pole Contactor For Alternator With Thermal Over Load Relay B) 160A, 4 Pole Contactor For Mains C) Mcb For Short Circuit Protection D) Indication Led (Dg On, Load On Dg, Main On, Load On Main, Battery Charge On) E) Push Buttons (Engine Start/Stop, Generator Contactor Close/Trip, Main Contactor Close/Trip If Provided, Fault Accept/Reset) F) Voltmeter & Ammeter And Other Connecting Accessories And Safety Features For Successful Auto Operation Of 100 Kva Dg Set. (Viii) Excavation, Earthwork And Provn Of Plain Cement Concrete Plinth Of Suitable Sizes For Installation Of Dg Set & Connected Accessories Complete As Per Oem/ Site Requirements. , S&F Square Profile Led Lighting Fixture With Extruded Polycorbonate, Environmental Friendly, Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output, With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. Make:Havells Led Pride Essential Cat No Lhexawp7un1w020 Or Equivalent Makes Cg/Philips/Wipro/Luker. , S&F Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb As Incomer Ip43 Protection Double Door: Plain 6 Way With Suitable Rated Busbar, Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separately. , S&F Mccb 4 Pole, 415 V, Adjustable Type Thermal Magnetic Release, 125 Amps With Breaking Capacity 25 Ka And Making Connection With Suitable Size Of Copper Lugs Etc Complete All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 50 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , M&L For Cutting Of Existing 40 Mm Dia Pipe For Inserting Tee Of Size 40X40x20 Mm Including Lead Joint And Excavation Etc Complete, All As Specified And As Directed , Supply, Install, Testing And Commissioning, Factory Made And Tested (Including Cpri Type Test Certified) Lt Panel Board Out Door Type, Floor Mounted, Compartmentalised And Ip-63 Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, All As Specified And Directed, Having Bus Bar Chamber With Insulated Aluminium Bus Bars 250 Amps Rating Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet And With Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Front And Rear Opening Type With Aprons For Cable Entry With Double Door Shutter And Locking Arrangement With And Including Following Items. (Notes : The Rate Quoted Shall Include Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ).Note: Panel Board Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. Incoming :- (A) Mccb 4 P, 415 Volt 160 Amps, 32Ka, 50 Hz With Fixed Thermal And Magnetic Setting -01 No Outgoing :- (B) Mccb 4 P, 415 Volt 125 Amps, 25Ka, 50 Hz -01 Nos. (C) Mccb 4 P, 415 Volt 63 Amps, 10 Ka, 50 Hz -02 Nos. (D) R,Y,B Indicators (E) Multifunction Digital Square Type Intelligent Panel Meter To Measure Voltage, Current, Frequency, & Power Factor - 01 No
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 13
Maharashtra View Result →
27.
Railways #11285147 AOC
Supply Of seven Varieties Of Utv Spares , 1.Brake Valve(Sa-9 ) Pt.No-Utvi-06 25/00-05 No, 2. C2w Relay Valve Pt.No-Utvi-06 13/00-05 No. 3.Throttle Valve Control Tc-2, Pt.No-Utvi-06 17/00-05 No. 4. Unloader Valve, Pt.No-Utvi-06 05/00-05 No. 5.Parking Brake Valve, Pt.No-Utvi-06 15/00-05No 6.Reducing Valve Pt.No: Utvi-06/22/00-05Nos. 7. Emergency Valve Pt.No:Utvi-06/19/00-05No,Emergency Brake Valve To Phooltas Part No : Utvi-06 19/00. Make: Phooltas Or Equivalen T [ Warranty Period: 12 Months After The Date Of Delivery ] ] , Pressure Reducing Valve To Phooltas Part No: Utvi-06 22/00. Make: Phooltas Or Equival Ent [ Warranty Period: 12 Months After The Date Of Delivery ] ] , Parking Break Valve To Phooltas Part No: Utvi-06 15/00. Make: Phooltas Or Equivalent [ Warranty Period: 12 Months After The Date Of Delivery ] ] , Air Unloader Valve (Sh) To Phooltas Part No: Utvi 06 05/00. Make: Phooltas Or Stone In Dia Only [ Warranty Period: 12 Months After The Date Of Delivery ] ] , Sa 9 In Dir Brake Valve To Phooltas Part.No -Utvi-06-25/00 Sil Part No - 30201407 , Id No :503067 Make: Phooltas Or Sil Only [ Warranty Period: 12 Months After The Date Of Delivery ] ] , C2w Relay Valve Oem: Utv/Rbmv To Phooltas Part No: Utvi-06 13/00. Make: Phooltas Or S Tone India Only. [ Warranty Period: 12 Months After The Date Of Delivery ] ] , Throttle Control Valve Tc-2 Way To Phooltas Pt No: Utvi-06 17/00 Or Tvs Pt No: M83 0030 Make: Phooltas Or Tvs Only. [ Warranty Period: 12 Months After The Date Of Delivery ] ] Page 1 Of 6 Run Date/Time: 25/04/2025 11:12:30Stores/Southern Rly Tender Document
Contract Date: Jun 15, 2026 Contract Value : 1.16 Lakh
Government Departments No of Bidders 1
28.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
29.
Petroleum and Natural Gas #11279164 AOC
Bids Are invited for Custom Bid For Services - Hiring Of One Time Services For Maintenance Of Field Instruments And Control Valve For Uran Plant Instrumentation Section - Removal From Line, Dismantling, Cleaning Of Valve & Actuator Parts, Inspection, Reassembly & Pressure Testing (For Leakage) & Actuator (For Pneumatic Supply Leakage). Supply & Replacement Of Gland Packing, Etc. To Arrest Leakage & Followed By Servicing Of I/P & Valve Positioner, Air Filter Regulator, Etc. & Its Calibration. Bonnet Gasket To Be Replaced With New (Unit Rate To Be Quoted Per Inch Of Valve Size) , Welding & Machining Of Valve (Inch Of Valve Size) , Lapping Of Control Valves: Lapping & Testing With Water / Air & Arresting Of Seat Leakage Within The Permissible Limit As Per Valve Data Sheet Or As Per Requirement (Unit Rate To Be Quoted Per Inch Of Valve Size) , Cage Grinding & Polishing (Unit Rate To Be Quoted Per Inch Of Valve Size) , Removal From Line And Installation Of The Valve Into The Pipe Line For Globe Valves, Butterfly Valves ,Shutoff Valves/On-Off Valves/Shutdown Valves& Ball Valves (Unit Rate To Be Quoted Per Inch Of Valve Size). , Stelliting At Seat Contact Of Valve Plug And Seat (Rate To Be Quoted As Per Inch Of Valves Size) , Online Servicing Of Control Valve Which Includes Servicing & Calibration Of Valve Positioner / Smart Positioner (Parts Replacement Not Covered) & I/P Converter, Stem Greasing, Servicing Of Filter Regulator, Relays And Stroke Checking - For All Type Valves & Actuator. , Disassembly Of Actuators (Including Piston Cylinder Actuators), Cleaning Of Parts, Greesing, Reassembly, Testing Of Joints, Testing And Calibration Of Actuators, Servicing, Cleaning And Calibration Of Positioners / Smart Positioners (Parts Replacement Not Covered), I/P & Air Filter Regulator (For Globe / Butterfly Valves) (Unit Rate To Be Quoted Per Inch Of Valve Size) , For 8 To 10 , For 4 To 6 , For 2 To 3 , Removal Of Level Gauges (Reflex / Magnetic) From The Flanges / Union Of The Vessels . Cleaning Of The Gauges And The Refitting The Same. If Any Leakage Found After Taking In Line, The Same Should Be Rectified By The Contractor.( Unit Rate To Be Quoted Per Gauge Glass). , Same As Item 120 But For Pvc Flanges/Valves,Cocks (Unit Rate To Be Quoted Per Guage Glass) , Level Switches & Transmitters : Dropping The Level Switches & Transmitters From The Vessel / Standpipe, Removal Of Floats, Cleaning Of Transmitters / Switches Cage Inside & Outside, Hydro Testing. After Hydro Testing, Refitting Of Floats & Flanges & Calibration Thereafter. (Unit Rate To Be Quoted Per No.) , Size : Up To 3 , Size : 4 To 6 , Size : 8 To 12 , Size : 14 And Above , Assembling & Dismantling Of Scaffolding As Per Requirement (Rate Per Cubic Meter) (Scaffolding Material Shall Be Provided By Ongc) , Valve Transportation Charges To And Fro (Unit Rate To Be Quoted Per Consignment) : , 2 1/2 , 3 , 4 , 6 , 8 To 12 , 14 To 20 , 22And Above
Contract Date: Ref. Documents Contract Value : 9.65 Lakh
Boards / Undertakings / PSU No of Bidders 2
Maharashtra View Result →
30.
Educational and Research Institute #11277941 Technical Bid
Tender For Purchase Of Lab Equipments-- 1 Purchase Of Lab Equipments 2 Acidity Test Kitspecifications:Ethyl Alcohol Sodium Carbonate Solution Universal Indicator Solution Laboratory-Grade Test Tubes Droppers Colour Comparison Chart For Test Result Comparison Chemicals Supplied In Labelled Containers With Safety Instructions Suitable For Laboratory Educational And Testing Applications 3 Single Phase Resistive Loadspecifications:Type: Single Phase Loading Rheostat Power Rating: 5 Kw Supply: 230 V Ac, Single Phase, 50 Hz Total Number Of Load Steps: 8 Approximate Dimensions: 18 × 18 × 22 Inches (L × B × H) Comprising Electrical Load Resistors Suitable For Laboratory Loading Applications Resistors Shall Be Special Cement-Insulated Type Mounted On Powder-Coated Ms Panel/Enclosure Individual On/Off Rotary Switches Provided For Load Selection Mounted On Rubber Wheels/Casters For Portability 4 Three Phase Resistive Load Specifications:Rating: 5.25 Kw Supply: 415 V Ac, 3-Phase, 50 Hz Total Number Of Load Steps: 6 Main Switch To Be Provided Approximate Dimensions: 18 × 18 × 22 Inches (L × B × H) Comprising Special Cement-Insulated Electrical Load Resistors Mounted On Powder-Coated Ms Panel/Enclosure Individual On/Off Rotary Switches For Load Selection Mounted On Rubber Wheels/Casters For Portability Suitable For Laboratory Load Testing Applications Proper Insulation, Ventilation, And Earthing Arrangement To Be Provided 5 Three Phase Capacitor Bank Specifications: 3-Phase Capacitor Bank Rating: 2 Kvar Voltage: 440 V Ac Frequency: 50 Hz Heavy Duty Self-Healing Capacitor Units Powder Coated Ms Enclosure Compact Panel Mounted/Floor Mounted Construction Proper Ventilation Arrangement To Be Provided Capacitor Duty Contactor/Switch To Be Provided Fuse/Mcb Protection To Be Provided Discharge Resistors To Be Provided For Safety Proper Earthing Arrangement Provided 6 3 Phase Auto Transformer Starter Specifications: 3-Phase Variable Autotransformer Input: 415 V Output: 0–470 V Ac (Continuous) Current: 15 A Copper Wound, Carbon Brush Type Heavy Duty Toroidal/Core Construction Mounted In Powder Coated Ms/Crca Enclosure Front Panel Mounted Voltage Control Knob With Scale Indication Proper Insulated Terminals Provided Floor/Bench Mounted Type Suitable For Laboratory Use Input / Output Terminal Arrangement Provided Mcb/Fuse Protection Provided Proper Earthing Terminal Provided Ventilation Arrangement For Heat Dissipation 7 3 Floor Lift Interfacing Model Specifications: Type: Table-Top Lift Model Floors: 3 Levels Structure: Transparent Acrylic / Ms Frame Cabin: Moving Lift Car With Guide Rails Drive: Dc Geared Motor / Stepper Motor Motion: Up/Down Movement, Floor Indication Leds (1, 2, 3) Direction Indicators (Up/Down), Start & Stop Atevery Stage, Over Load Limit Control Three-Floor Lift Operation Plc Interfacing And Programming Floor Selection Logic Automatic Stopping At Floors Direction Indication System Educational Demonstration Of Elevator Automation 8 Mcb Elcb Trainer Kit Specifications: 1 Phase/3 Phase, 2/3/4 Pole, 3A-16A Single Pole Mcb 2-5Amps Two Pole Elcb 30Ma Lamp Load Single Phase 5Amps Panel Enclosure And Terminal Outlets 9 Signal Generator Specifications: Frequency Range: 0.1 Hz To 5 Mhz. Display: 4 To 6 Digit Led Display Output Waveforms: Sine, Triangle, Square, ± Pulse, ± Ramp. Amplitude: 0 – 20 Vp-P. Rise Time: 10 Dso Specifications: Bandwidth: 50 - 100 Mhz. Sampling Rate: 1Gs/S. Channels: 2 (Minimum) Power Supply: 100V–240V Ac, 50-60 Hz Automatic Measurement: Vpp, Vavg,Rms, Frequency, Period, Vmax, Vmin, Rise Time, Fall Time, + Width, - Width, +Duty, - Duty Etc., Horizontal Scale: 5 Ns/Div – 50 S/Div Or Equivalent Vertical Resolution: 8 Bits (2 Channels Simultaneously) Vertical Sensitivity: 1 Mv/Div – 10 V/Div (At Input) Waveform Math: +, -, X , ÷, Invert, Fft Etc., Waveform Storage: 16 Waveforms Or Equivalent Communication Interface: Usb Host, Usb Interface. 7-Inch Color Display Or Equivalent Input Impedance - 1 Mω ±2%, // 20 Pf 2 × Passive Probes (1X/10X) 11 Pwm Based Step Down Dc Chopper Using Mosfet/Igbt Kit Specifications: Pwm Based Step-Down Dc Chopper (Buck Converter) Power Device : Power Mosfet / Igbt Based Switching Circuit Input Supply : 24 V Dc To 110 V Dc Or Derived From 230 V Ac Mains Through Rectifier Unit Output Voltage :(0 To Vin) Variable Dc Output Current : Up To 5 A Dc Maximum With Suitable Load Resistor (R Load) Pwm Duty Cycle Control Provided Pwm Generation And Control Circuit Inbuilt Gate Driver Circuit Provided 12 Dual Output Regulated Dc Variable Power Supplyspecifications: • Input Voltage: 230V/50 Hz Ac. • Output Voltage: (0–30)V Dc. • Output Current: (0–2)A Dc. • Protection Circuit: Over Voltage, Over Current, And Short-Circuit Protection. • High Efficiency: Greater Than 85%. • Low Ripple And Noise: Less Than 50 Mv. • Digital Display. 13 8051 Micro Controller Kit Specifications: • Operating Voltage: +5 V Dc. • Flash Memory: 4 Kb (At89C51) / 8 Kb (At89S52). • Ram: 128 Bytes Internal Ram. • 16 × 2 Alphanumeric Lcd Display. • Push Buttons / Tactile Switches. • Dip Switches For Digital Input. • Inbuilt Adc Interface: Ldr, Potentiometer. • Inbuilt Dac Interface. • Inbuilt Stepper Motor Driver With Stepper Motor. • Inbuilt Dc Motor Driver With Dc Motor. • 1 × 4 Led Array, 1 × 4 Keypad, 1 × Relay. • 1 × Buzzer, 16 × 2 Lcd Display, 1 × Pwm Driver. • 1 × Hardware Interrupt Key, Inbuilt Rtc. • Inbuilt Eeprom And Uart Module. • 4 × 7-Segment Display. • Supports Both Assembly And C Language Programming. • Pc Interfaceable. 14 Stepper Motor Drive Kit Specifications: Working Model 8051 Micro Controller Kit Capable For Stepper Motor Drive Kit 15 Digital Trainer Kit Specifications: 5V Dc, 1A Regulated Power Supply ±12V Dc / ±15V, 200 Ma Regulated Power Supply Solderless Breadboard To Accommodate 8 × 16-Pin Ics, Zif (Zero Insertion Force) Ic Sockets Logic Input And Output Leds For Output Monitoring 16 Buffered Led Outputs 16 Debounced Switch Inputs Variable Clock Generator: 0.5 Hz To 50 Hz Single Pulse Output: 100 Ms (Buffered, Positive And Negative Outputs) One Seven-Segment Display With 4 Bcd Inputs Built-In Logic Probes Built-In Logic Switches Manual Clock: Debounced Push Button (One Pulse Per Press) 16 8 Bit Adc/Dac Interface Boardspecifications: • Thermistor / Lm35 Input In One Channel. • Variable Input (0–5) V In Another Channel. • 8 Leds For Digital Output Indication.• Necessary Control Signals Provided For Adc0809. • 8-Bit Dac Using Dac0808. • 8-Bit Digital Input From Controller. • Single-Channel Dac Output:(0–10) V. • Power Supply:±12 V Or ±15 V For Analog Circuitry Please Enable Macros To View Boq Information = Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Jun 12, 2026 Contract Value : 2.48 Lakh
Government Departments No of Bidders 1
34.
Defence #11266541 AOC
Bids Are Invited For Es4929b-C60h-10A - 2P Mcb10ac Curve , Es4929b-C60h-25A - 2P Mcb25ac Curve , Es4929b-Cad50 - Schnider Contactor 10A,5 No, 690V, 24V Dc Coil , Es4929b-Nsx160f-Dc-Tm160 - Schnider Mccb, Tm160 Dc, 160 A , Es4929b-Nsx160f-Dc-Tm80 - Schnider Mccb, Tm80 Dc, 80 A , Es4929b-Zb4-Bk1333-1-0-2 - Turn Button , Es4929b-1Sax121001r1104 - Ef19-6.3 - Electronic Overload Relay For Af09 Af38 , Es4929b-1Sax221001r1101 - Ef45-30 - Electronic Overload Relay For Af09...Af38 , Es4929b-1Sbl237001r1300 - Contactor Af26-30-00-13 - 3P - Ac3 400V 26A , Es4929b-415-230100Va - Transformer 415/230V 100Va , Es4929b-415-230220Va - Transformer 415/230V 220Va , Es4929b-440-230-24V100-50Va - Transformer,415 /230 V+ 24V 100+50 Va , Es4929b-440-230-24V220-60Va - Transformer,415 /230 V+ 24V 220+60 Va , Es4929b-A9f54204 - Ic60h/B 4A 2P Circuit Breaker , Es4929b-A9n3p06c - 6 Amps Tp 10 Ka Mcb , Es4929b-A9n3p50c - 50 Amps Tp 10 Ka Mcb , Es4929b-C60h-20A - 2P Mcb20ac Curve , Es4929b-C60h-32A - 2P Mcb32ac Curve , Es4929b-Gv2-Mc02 - Enclosure For Motor Circuit Breaker,32A , Es4929b-Gv2me03 - Schneider Overload Breaker 3P,0.25-0.4A,690V , Es4929b-Gv2-Me05 - Mcb 3P, 0.6-1A,400V , Es4929b-Gv2-Me07 - 3 415V, 1.6-2.5Amp Motor Circuit Breaker , Es4929b-Gv2-Me08 - 3 415V, 4-6.3Amp Motor Circuit Breaker , Es4929b-Gv2-P16 - 3 415V, 9-14Amp Motor Circuit Breaker , Es4929b-Gv2-P20 - 3 415V, 13-18Amp Motor Circuit Breaker , Es4929b-Gv2-P21 - 3 415V, 13-18Amp Mcb , Es4929b-Gv3-P65 - 3 415V, 48-65Amp Motor Circuit Breaker , Es4929b-Gvad0110 - Add. Block Protection Unit, 1No+1Nc,6A/240V , Es4929b-Gv-An11 - Add. Block, 48-65Amp Trip Unit , Es4929b-Gv-Au225 - Under Voltage Release 220V, 50 Hz, For Mcb , Es4929b-Gv-Au385 - Under Voltage Release 400V, 50 Hz, For Mcb , Es4929b-Ins250 3P - Schneider Switch Disconnector 3P 250A , Es4929b-La1-Kn40 - Add.Block Aux Contacts 4No, 10 A , Es4929b-Ladr4 - Add. Time Delay Block Aux Contacts,1No+1Nc,10A , Es4929b-Lc1-D09p7 - Contactor 440V,3P, 9A, 230V Ac Coil , Es4929b-Lc1d115p7 - Schneider Main Contactor 440V,115A,3P,1No+Nc Contact , Es4929b-Lc1-D18ap7 - Schnider Contactor 3P 3No, 440V 18A, 230V Coil , Es4929b-Lc1-D18p7 - Contactor 440V,3P, 18A, 230V Ac Coil , Es4929b-Lc1-D65ap7 - Contactor ,3 415V, 48-65Amp , Es4929b-Lc1-K0910m7 - Contactor 3P Ac, 440 V ,9A Aux 1 No. , Es4929b-Lv429795-Nsx100n-M - Circuit Breaker Compact Nsx 100N, 50Ka At 415V Ac Micro , Es4929b-Lv510306 - 80 Amps Tp 25 Ka Mccb , Es4929b-M6200a0a0b0a0a0p - Digital Kw Meter (With Option Card Code 8) , Es4929b-Rxm4ab1p7 - Plug In Relay, D02, 6A, 4 C/O 230V Ac , Es4929b-S8vk-G06024 - Omron Power Supply Pls 220V/24Vdc , Es4929b-Type428a - Mcb Distribution Box 440X370x130 , Es4929b-Xb4-Bvm3 - Pilot Light, Signal Lamp, 230V Ac , Es4929b-Xb4-Bw33m5 - Switch Start, 240V Ac,1No/1Nc , Es4929b-Zb4bd5 - Selector Switch, 3 Position , Es4929b-Zb4-Bk1533-1-0-2 - Turn Button, 690V,20A , Es4929b-Zb4-Bvm3 - Signal Lamp, 230V , Es4929b-Zb4-Bz009 - Bracket For Selector Switch , Es4929b-Zbe101-No - Add. Single Block Contact,1No,6A,600V , Es4929b-Zbe102-Nc - Add. Single Block Contact,1Nc,10A,600V , Es4929b-Zbv-B1 - Power On Indication (White), Schnider Total Quantity : 135
Contract Date: Ref. Documents Contract Value : 8.64 Lakh
Government Departments No of Bidders 1
Andhra Pradesh View Result →
Contract Date: Jun 11, 2026 Contract Value : 3.10 Lakh
Government Departments No of Bidders 1
37.
Agriculture #11260240 Technical Bid
Tender For Supply Of Electrical Spares Item , Electrical Spares Item , {Electrical Store/Material} Hf Hrc Fuse Link 63A, 415 V Ac, 14X51 Cylindrical Type, 80 Ka, Make : L&T (El0363) Hf Type, 63 Annual Periodical Maintenance , {Electrical Store/Material} Hrc Fuse 320 Annual Periodical Maintenance Din Type 170M3817D Bussmann (El0371) Semiconductor Fuse, Type -170M3817D , Electrical Store/Material} Hrc Fuse Links 16A, 415V,Ofafn00Gg, 80Ka Abb (El0356) Type - Ofafn00Gg , Electrical Store/Material} Hrc Fuses 100A 3Na78030Rc (Din)- 120Ka,Make :Siemens (El0365) Type - 3Na78030Rc, 100Amp , Electrical Store/Material} Hrc Fuses 16A 3Na78050Rc (Din)- 120Ka,Make :Siemens (El0348) Type - 3Na78050Rc, 16 Amp, Nh000 , Electrical Store/Material} Hrc Semiconductor Fuse 1000 Annual Periodical Maintenance (690V) (El0373) 1000 Amp,690Vac, Type - 170M6814D, Din-3, Semiconductor Fuse , Electrical Store/Material} Hrc-Fuse 600/630 Annual Periodical Maintenance (El0374) 630 Amp, Type - Nh3 (469) , Electrical Store/Material} Copper Flexible Flate Cable 3Cx2.5Sq. Mm (El0169) , {Electrical Store/Material} P.V.C.Flex. Copper Round Wire 3 Core*1.5Mm2 (El0518) , Electrical Store/Material} Pvc Allu. Flate Wire 2Core *1.5Mm2 (El0515) , {Electrical Store/Material} Pvc Alluminium Flate Wire 2 Core * 2.5Mm (El0514) , Electrical Store/Material} Pvc Copper Wire 2.5 Mm Single Core (El0164) , {Electrical Store/Material} Pvc Flexible Copper Cable 2 Core 2.5 Mm (El0168) , Electrical Store/Material} Pvc Flexible Round Copper Cable 3Corex2.5Mm (El0519) , {Electrical Store/Material} Pvc Flexible Round Copper Cable 3Corex4Mm (El0163) , {Electrical Store/Material} Pvc Flexible Round Copper Cable 4Corex4Mm (El1085) , Electrical Store/Material} Pvc Insulated Flexible Unarmed Round Copper Cable 4Corex25Sqmm (El0522) (470) , Electrical Store/Material} Air Break Power Contactor 1Sbh143001R8122 Nl22E 24V Dc 2No+2Nc,Make : Abb (El0270) Model - Nl22E, Coil Voltage - 24 Volt Dc , Electrical Store/Material} Air Break Power Contactor 1Sbh143001R8122 Nl22E 24V Dc 2No+2Nc,Make : Abb (El0270) Model - Nl22E, Coil Voltage - 24 Volt Dc , Electrical Store/Material} Air Break Power Contactor Lcif 265,Coil Volt-220Vac Make : Schneider (El0204) , Electrical Store/Material} Cbct Make-Schneider,630/0.15A. Cl-3.0, Item Code- Ct34P,Material Code-S1A11721,Drawing No.- Sia1166402,Hsv/Il-0.66/3Kv For 1 Min, As Per Is2705 (El0762) , {Electrical Store/Material} Gfp 13 Relay Module For Ct33P&Ct34P Mccb Make- Schneider,Modie-Gfp13,Make-Schneider,Ct Ratio- 630A/0.15A,Time Delay 0.5 To Inst.{Sec),Sensitiivity 10 To 60%Xln (El0451) , Electrical Store/Material} Mccb Type-Dy 125U,100Amp Make : L&T (El0887) , Electrical Store/Material} Mpcb 3Vu1340-Imjoo 3.2-5.0A,Make: Siemens (El0904) , {Electrical Store/Material} Mpcb 3Vu1340-Inl0D 8-13A,Make: Siemens (El0900) , Electrical Store/Material} Mpcb Auxiliary Contact Block(2 No+ 2Nc) Siemens 3Rv1901‐1A (El1478) Aux Contact Block For Mpcb , 1No + 1 Nc , Electrical Store/Material} Mpcb Auxiliary Contact Block(2 No+ 2Nc) Siemens 3Rv1901‐1A (El1478) Aux Contact Block For Mpcb , 1No + 1 Nc , {Electrical Store/Material} Power Contractor Icie 50M7, 220V (El0187) Model - Lc1E 50M7, Coil Voltage - 220Vac , {Electrical Store/Material} Spare Contactor Kit Lc1F 160,Make: Schnieder (El1226) , Electrical Store/Material} Spare Kit For 3Tf52 Contactor Make :Siemens,3Ty7520-0Ya (El1154) , Electrical Store/Material} Switch Disconnector Fuse Unit 630 Amp, Model: Cvs 630N, 690Vac,Uimp 8Kv,Ue(V)220/240, Iec/En 60947-2 Make : Schneider (El0310) (471) , Electrical Store/Material} Air Break Power Contactor 1Sbl177001R1110, Af16-30-10-11,Make : Abb (El0272) Model - Af16(Af16-22-00-11), Coil Voltage 20-60 Volt Dc, 50/60 Hz , {Electrical Store/Material} Axial Fan ,Make-Ebm Papst,Model-2218F/2 Tdhhp, 48Vdc, 1.0Amp, 48Watt, 5000R/Min, Var .233Ep, (36-72V Dc), Pin- 3Axd50000037992A, 4Wire, (El0256) , {Electrical Store/Material} Contactor , Make - Abb, Model -Af370-30 Coil Code- 11, 24-60V 50/60Hz, 20-60V Dc (El0216) Model - Af16(Af16-22-00-11), Coil Code-11, Coil Voltage 24-60 Volt, 50/60 Hz, 20-60V Dc , {Electrical Store/Material} Vfd 5.5Kw , 7.5 Hp Model Acs 355 - 03E-12A5-4, Ip-20/Ul Open Type, Ul Type 1 With Multi 1 Option, Pn 5.5Kw, 7.5 Hp U1 3 Ph 400V-480V,I1 19A/16A, I1 With Ext. Choke 11A/9.5A, F1 48-63 Hz, U2 3Ph 0-U1V, I2 12.5A (150% 1/10 Min.),F2 0-599 Hz. (El1541) Vfd With Cdp Display , {Electrical Store/Material} Vfd 7.5Kw , 10 Hp Model Acs 355 - 03E-15A5-6, Ip-20/Ul Open Type, Ul Type 1 With Multi 1 Option, Pn 7.5Kw, 10 Hp U1 3 Ph 400V-480V,I1 22A/18A, I1 With Ext. Choke 12A/10A, F1 48-63 Hz, U2 3Ph 0-U1V, I2 15.6A (150% 1/10 Min.),F2 0-599 Hz. (El1542) Vfd With Cdp Display (472) , Electrical Store/Material} 3 Phase Induction Motor Abb 3Kw, Voltage‐ 415±10% Amp‐6.5A Rpm‐ 1443 Duty‐S1 Frame Size‐ M2Bax100Lb4, Type‐ 1Mb14/1M3601 (El0106) Flange Mounted , Electrical Store/Material} 3 Phase Slipring Induction Motor, 3.4 Kw Rpm‐ 900 Voltage 415Vac, Rotor Voltage 110 V, Rotor Current 21A (El0087) Foot Mounted , Duty- S4, Type - Mp13M613, Ip - 55, Con. 415 Star, Ins.Cl - F, , Electrical Store/Material} 3Phase Induction Motor 3.7Kw(5Hp)Voltage‐ 690Vac Currunt‐ 4.2Amp Rpm 1440 Duty S1, Connection‐ Star Frame Size‐ Sev112M, Flange Mounted , Marathon (El0105) , Electrical Store/Material} Air Circuit Breaker, Abb Sace Emax, Model‐ Sace E1N 08, Iu=800A, Ue=690Vac, 3 Pole (El1530) Type - Draw Out , Electrical Store/Material} Induction Electric Motor 3 Phase 2.2Kw, Rpm1440, Eff 84.3,Pf 0.85,690Vac,Fram Size Se100L,Ip55,50Hz,Type Tefc Make : Marithon (El0430) Foot Mounted , Electrical Store/Material} Power Capictor 25 Kvr (El1602) Model- App-B25160C4027T780, Fn - 50, Con. -3 Phase Delta, 415 Volt - 20.7 Kvar -28.8 A, 440Volt - 23.3 Kvar - 30.5 A, 480Volt - 27.7 Kvar - 33.3 A (473)
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 7
38.
Water Resources and Irrigation #11259242 Price Bid
Tender for Repairs To 25 Hp Motor Of Hc Pump Unit I, Starter Of Pumping Unit I Along With Other Allied Works At Lis Rathana. , Decoupling Of 5 Cusec Pump Of Hc Pump Unit No I From Motor And Then Dismantling The Motor And Pump From The Base Frame. Carriage & Shifting Of Dismantled Motor Of Lift Irrigation Station Rathana On Head Load Through Path In Fields To Roadside Using Manual Labour And Then To Workshop By Carriage Vehicle. Repairs To 25 Hp Motor Of Pumping Unit No I Of Lift Irrigation Station Rathana By Extracting Out Old Damaged Winding Manually And Cleaning Of Stator Slots. Complete Rewinding Of The Stator By Using Standard Copper Wire Of Requisite Gauge. Varnishing After Rewinding Of Stator. Repair To Rotor Shaft By Way Of Metal Filling With Welding, Turning And Finishing To Required Size. Providing And Fitting Of New Bearings-2 NoS On Driving And Non Driving Ends Of The Motor, Bearing Plates- 2 NoS, End Terminals, Nuts And Bolts.Job Includes Cost Of Material, Labour Charges, Fitting And Installation Charges Of Motor At Site. The Firm Should Quote Rate Including The Rebate On Old Copper Scrap. Replacement Of Coupling Pulley Of Pumping Unit No I By Way Of Fabrication Of New Coupling Set As Per Sample And According To The Size Of Motor And Pump Shaft. Providing And Fitting Of 8 NoS New Coupling Nuts & Bolts, Rubber Bushes& Key Way. Repair To Panel Cum Starter Of 25Hp Of Pumping Unit I At Lis Rathana By Way Of Replacing Protection Relay, Replacing Of Damaged 01 No Contractor. Making All The Electric Connections And Testing The Panel On Partial/Full Load Repair To 200 Mm Diameter Foot Valve Of Pumping Unit No I By Way Of Dismantling Parts. Cleaning Of All Internal Parts To Remove Silt And Rust. Fabrication Of Foot Valve Plate As Per Size, New Leather Washer, Hinge Pin, New Nuts & Bolts. The Job Includes Dismantling And Fitting It With Foot Valve At The End Of Suction Pipe. Back Shifting After Carrying Out Repairs Of Motor, Foot Valve & Starter To Site. The Job Includes Loading, Un-Loading, Fitting, Testing, Manual Labour, Carriage Charges Of Vehicle (To & Fro), Tools & Tackles Etc. Complete Job Note:- The Tenderers Are Requested To Visit The Site And Quote The Rate Including Rebate On Old Parts As Per Site Conditions. Any Modifications/ Alterations Of The Job, Absolutely Necessary If Required At The Time Of Execution May Be Done As Per Actual Site Conditions. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
39.
Housing Urban and Rular Development #11259231 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Repair/Servicing And Maintenance Of 66Tr Packaged Air Conditioning Unitsin Ward No. 19 Of Govt. Smgs Hospital, Jammu.. Mhdj/E-Nit 20 Of 2026-27 Dated: 25.04.2026 Due : 04.05.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Repair/Servicing And Maintenance Of 66Tr Packaged Air Conditioning Units In Ward No.19 At Govt. Smgs Hospital Jammu. Servicing Of Blowers By Way Of Alignment Checking, Strengthening To Blower Brackets And Testing At Site - 2 Jobs. Complete Servicing Of Idu Coil And Odu Unit Chemical Or Water, As Per Site Requirement, Through Pump To Remove Unwanted Dust From It And Also Washing And Cleaning Of Air Filters, Drainage, Line Cleaning Etc. For At Least Two Times At Periodic Interval- 4 Jobs. Recharging Compressors With 20 Kg Refrigerant-R410 Gas - 1 Job. Replacing Of Worn-Out Fan Belts As Per Requirement- 6 Nos. Repair Of Outdoor Fan Motors By Way Replacement/Rewinding Of Old Damaged/Worn-Out Motors As Per Requirement - 2 Nos. Replacing Of Worn-Out/Damaged Pcbs As Per Sample- 1 Nos. Restoration By Way Of Replacement Of Worn-Out/Damaged Electrical Wires/Cables Of Assorted Sizes In Order To Replace Worn-Out/Damaged Wire/Cables Of Electrical Panel Of Idu.Replacement Of Worn-Out/Damaged Contactors - 3 Nos. And Tpn (63 A) - 3 Nos. Or As Per Site Requirements.Providing And Fitting Of Protection/ Monitoring Relays As Per Site Requirement - 1 Job. Replacement Of 150 Kva Avr Protection Relay By Way Of Supply Installation Testing and Commissioning of New Relayas Per Sample. The Job Further Includes Replacement Of Control Wiring And Replacement Of Old Worn-Out/ Damaged 4P 200 A 50 Ka Bcc At Site With New One Along By Way Of Supply Installation Testing and Commissioning of New One As Per Sample Using Special Tools And Tackles Along With Manual Labour As Per Site Requirement.Complete Job As Per Directions Of Engineer-In-Charge And Includes Cost Of Material, All Kinds Of Taxes, Labour Charges, Tools & Tackles, Other Unforeseen Materials Required For Execution Of Job And Also Involves Cost Of Technicians, As And When Required To Attend The Complaints Of Machines And Its Rectification. Moreover, All The Electro-Mechanical Materials Used Should Conform To Relevant Is/Bis/Ce Standards And Codes. Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
40.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
41.
Public Administrative Department #11249892 Price Bid
Tender for Supplying, Lowering, Testing And Commissioning Of Vertical Type, Multistage, Totally Enclosed Water Filled Deep Well Submersible Pumping Set Complete I/C Connection Etc. As Reqdd Three Phase 5.0 Hp Having Discharge Of 108 Lpm Approx. At 92 M Head. , Supply, Installation, Testing And Commissioning Of Cubical Type Control Panel Board For Single Phase & Three Phase Submersible Pumping Set Of Following Rating Complete With Contactor, Relay , Mcb ,Condenser ,Voltmeter, Ammeter And Indication Lamp Etc Including Connections Etc As Reqd.D 5 Hp (Three Phase) , P&F Following Sizes Of Pvc Insulated & Pvc Sheathed Copper Conductor 3 Core Submersible Cable Confirming To Is.694/1990 Etc. As Reqd.C 3X4sq.Mm , Supply, Installation, Testing and Commissioning Of Hot Press Moulded Smc Panel/Canopy Box Of Size(Od) 920 Mm X 460 Mm X 260 Mm & (Id) 900 Mm X 450 Mm X250 Mm , Anti - Corrosive, Dust Proof, Rust Proof, Shock Proof , Self-Extinguishing Property , Resistant To Heat , Vermin Proof, Ultra Violet Stabilized, Pilfer Resistant, Suitable For Mounting 1 No. 3 Phase Starter, 1 No. 63 annual periodical maintenance 4 Pole Isolator And 1 No. 3 Phase Energy Meter, Socket For Outgoing Connection With Pilferage Proof Smc Door Duly Welded With S/S Handle Having Danger Logo On Its Outer Surface And With 1 No Hot Dip Galvanized Iron Stand For A Base Of Size 40 Mm X 40 Mm X 5 Mm And Height Of The Stand Is 600 Mm Including 300 Mm Height Below The Ground With Side Strip Of Size 25 X 5 Mm , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63A , Supply Of Xlpe Insulated Pvc Sheathed Al. Conductor Armoured Cable 1.1Kv Grade Conforming To Is-7098 Of Following Size:-4C*6 Sqmm , Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground (75 Cm Below Ground Level) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required.63 Mm Dia (Od-63 Mm & Id-51 Mm Nominal). , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. Upto 35 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required , Boring/Drilling Bore Well Of Required Dia For Casing/ Strainer Pipe, By Suitable Method Prescribed In Is: 2800 (Part I), Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart/ Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90 Metre Depth Below Ground Level.(A)All Types Of Soil 300 Mm Dia , Rocky Strata Including Boulders 300 Mm Dia , Boring/Drilling Bore Well Of Required Dia For Casing/ Strainer Pipe, By Suitable Method Prescribed In Is: 2800 (Part I), Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart/ Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer -In-Charge, Beyond 90 Metre & Upto 150 Metre Depth Below Ground Level. Rocky Strata Including Boulders 300 Mm Dia , Providing, Lowering And Fixing/Placing In Vertical Position Ms Slotted Casing Medium ( B-Class) Pipe Of Following Size Conforming To Is 1239/3589 Part-I (2004) At All Depth, Both Ends Threaded As Required.C) 200Mm(Nominal Bore) , Providing, Lowering And Fixing/Placing In Vertical Position Ms Slotted Casing Medium ( B-Class) Pipe Of Following Size Conforming To Is 1239/3589 Part-I (2004) At All Depth, Both Ends Threaded As Required.C) 150Mm(Nominal Bore) , Providing, Lowering And Fixing/Placing In Vertical Position Ms Black Casing Medium ( B-Class) Pipe Of Following Size Conforming To Is 1239/3589 Part-I (2004) At All Depth, Both Ends Threaded As Required.C) 200Mm(Nominal Bore) , Providing, Lowering And Fixing/Placing In Vertical Position Ms Black Casing Medium ( B-Class) Pipe Of Following Size Conforming To Is 1239/3589 Part-I (2004) At All Depth, Both Ends Threaded As Required.C) B) 150Mm(Nominal Bore) , Supply, Lowering And Fixing Following Size Of G.I. Pipe (M-Class) I/C Cutting Threading On Both Sides Etc. Isi Marked Etc As Reqd.D) 50Mm(Nominal Bore) , Gravel Packing In Tubewell Construction In Accordance With Is: 4097,Including Providing Gravel Fine/ Medium/ Coarse, In Required Grading &Sizes As Per Actual Requirement, All Complete As Per Direction Of Engineer-In-Charge , Supplying And Fixing Following Sizes Of Insulated Steel Flexible Safety Rope For Holding Submersible Pump Set I/C Clips Etc Complete As Reqd.A 6 Mm , Development Of Tube Well In Accordance With Is : 2800 (Part I) And Is: 11189, To Establish Maximum Rate Of Usable Water Yield Without Sand Content (Beyond Permissible Limit), With Required Capacity Air Compressor, Running The Compressor For Required Time Till Well Is Fully Developed, Measuring Yield Of Well By V Notch Method Or Any Other Approved Method, Measuring Static Level & Draw Down Etc. By Step Draw Down Method, Collecting Water Samples & Getting Tested In Approved Laboratory, I/C Disinfection Of Tubewell, All Complete, Including Hire & Labour Charges Of Air Compressor, Tools & Accessories Etc., All As Per Requirement And Direction Of Engineer-In-Charge. , S & F Ms Clamp Made Up Of Iron Flat Of Size 50X6 Mm With 4 Nut Bolt For Holding The Gi Pipe Pipe As Reqd. 50 Mm , S & F Following Size Of G.I. Socket. As Reqd. 50M , S & F Following Size Of G.I. Elbow. As Reqd.. 50Mm , S & F Following Size Of G.I. Union. As Reqd.50Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
43.
Railways #11247924 AOC
Supply Of Relay Qnnirelay Qnni,Q-Series Twin Neutral Line Relay Qnn1 Type, 6F/2B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc. And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acdek. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn-1 Type, 4F/4B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acehj. [ Warranty Period: 30 Months After The D Ate Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn1 Type, 6F/2B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc. And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acdek. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn-1 Type, 4F/4B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acehj. [ Warranty Period: 30 Months After The D Ate Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn1 Type, 6F/2B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc. And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acdek. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn-1 Type, 4F/4B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acehj. [ Warranty Period: 30 Months After The D Ate Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn1 Type, 6F/2B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc. And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acdek. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn1 Type, 6F/2B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc. And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acdek. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Q-Series Twin Neutral Line Relay Qnn-1 Type, 4F/4B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acehj. [ Warranty Period: 30 Months After The D Ate Of Delivery ] ] Page 2 Of 8 Run Date/Time: 20/11/2025 16:08:55Stores/North Western Rly Tender Document , Q-Series Twin Neutral Line Relay Qnn-1 Type, 4F/4B, 24V Dc Complete With Plug Board ( Base Plate), Connectors And Retaining Clips Etc And Conforming To Brs-960 And Rdso Spec.No.Irs:S-3 4 & S-23. The Interlocking Code For This Unit Shall Be Acehj. [ Warranty Period: 30 Months After The D Ate Of Delivery ] ]
Contract Date: Jun 09, 2026 Contract Value : 2.69 Crore
Government Departments No of Bidders 1
46.
Power #11237449 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Residential; 2755929; Service Provider - Operation And Maintenance Of Water Treatment Plant Having One Flash Mixer With Agitator And Clarification Tank Having Rotating Bridge, Two Filter Beds, One Chemical House Having Two Alum Solution Tanks With Agitator, 132 Kl Overhead Tank, One Sump Well And Its Pumps Motor Filter Water Sump And 1To 3 Nos Pumps And Motor Upto 30 Hp, 2 Nos Pumps And Motor Upto 60Hp, And All Other Accessories Including Cleaning Of Clarification Tank , Filter Water Reservoir Tank 2 Nos With Site Pit And Out Side Back Wash Pit Including Cost Of All Labour T&P , Cost Of All Consumables Such As Grease, Lubricating Oil, Mobil Oil, Gear Oil, Packing Seat, Coupling Of Gear Box , Gland Dori Etc. Required For Proper Completion Of Work. Work Includes The Up Keeping And Cleaning Of Surrounding Area Of Filteration Plant, Daily Collection Of Treated Water S Le From Filteration Plant And Submitting The Same To Chemistry Lab Of 2X210mw For Testing And Collection Of Report And Maintaning The Test Register. Work Also Includes The Watch & Ward Of The Filtration Plant Complax Round The Clock And Daily Cleaning/Dusting Of All Equipments Fixed At Filteration Plant As Pump, Motors, Main Switches, Starters Etc. And Disposal Of Debries Out Side The Periphery Of Filtration Plant. , Operation Of Tube Well Daily By A Suitable Experienced Operator Continuously Or In Different Intervals As Per Program Fixed By Engineer-In-Charge Including Opening And Closing Of Valves, Greasing Of Motor, Changing Of Fuse Wire Etc. As Required For Proper Running Of Tube Well/Pump Set Of 15 Hp Inside Power House Area (Store Area). , Operation Of Over Head Tank 190 Kl And Pump House Near Type-Ii Area (Near Ministrial Club) As Required Including All Valves, Indicator And Cleaning Of Stairs, Structure And Area Inside Boundary Wall And Its Watch And Ward 24 Hrs. Daily. , Operation Of Pump Set Of 15 Hp And Tubewell Near Inter College Area (Type Iii) As Required Three Times Daily , Re-Winding Of Ac Mono Block, 3 Phase Motor, With Best Quality Insulating Material, Including All Charges Of Dismantling Of Motor And Its Pertaining Items Such As Suction And Delivery Pipes If Required And Stacking In Departmental Store And Including All Charges For Re Fixing Of Motor And Also Fixing Of Motor At Any Tube Well/ Pump House As Per Direction Of Engineer- In -Charge, Including Supply And Fixing Of All Material Like Nut, Bolt, Washer Packing Welding Grinding Of Shaft Etc. And Testing Of Motor Etc. All Complete . All Waste Material Like Burnt Wire Shall Be The Property Of The Contractor.3 Hp To 5 Hp , 7.5 Hp To 10 Hp , 15 Hp , Same As Item No 5 But Rewinding Of Submersible Motor Of Following Pump.1 Hp To 3 Hp , 5 Hp To 7.5 Hp , Repairing Of Following Submersible Pump Including All Charges Of Dismantling Pump And Its Purchasing Item Such As T&P Etc.1 Hp To 3 Hp , 5 Hp To 7.5 Hp , Providing & Fixing Of Bearings S.K.F. Or Nbc (From Main Distributor Produced With Orignal Cash Memo) Equivalent Make Including Removing Of Bearing From Pump/Motor Including Cost Of All Labours Material, T&P Etc. All Complete, 3 Hp To 5 Hp , 7.5 Hp To 10 Hp , 15 Hp , Supply & Filling Of 16/30 Gauge Approved Ram Nager Betwa Sand In Filter Bed Of Filtration Plant Situated In Colony Area Of Parichha Thermal Project, Parichha. , Taking Out Of Gear Box Fixed A Colony Water Treatment Plant Rotating Bridge, Opening Its Nut & Bolts, Replacement Of Gear Oil Big Oil Seal No. (Kds/1335/P25 Die 175.3), Small Oil Seal No. Kds-2705, Including Packing , Oiling, Tightening Of Nut & Bolts And Assembling , Reerecting , Repairing The Same On Bridge With Flocculate Or Rotating Bridge Including Making Proper Alignment With All Required Arrangements Including The Cost Of All Material, T&P Etc. Required For Proper Completion Of Work. , Repair Of Warm Shaft And Gear Of Gearbox Of Suitable Make By Filling Of Required Type Of Material Over Gear And Shaft (Warm Shaft) And Cutting Grove, Thread Etc. Over If On The Lathe Machine As Per Specification. Including The Cost Of All Material, T&P, Carriage Etc. Required For Proper Completion Of Work. , Same As In Item No 17 Above But For Providing And Fixing Of Rotating Shaft , Providing Fixing Of Thrust Bearings S.K.F. Or Nbc Make Of Approved Quality For Reduction Gearbox Of Approved Make And Including Removal Of Old Bearing, Checking Of Bore Size Inner And Outer And Fixing It In Proper Alignment Including Cost Of All Labours Material, T&P Etc. All Complete, For Warm Shaft (Gear Shaft) , For Rotating Shaft. , Opening Out Complete Assembly Of 25 Hp Pump And Column Pipes Fitted Of The Pump House Near 450 Kl Over Head Take, Repairing And Re-Fixing Including Other Cost Of All Material Such As Rubber Bush Bearing, Nut Bolts And Gland Plate Etc. Machinery Work, Grinding, Cutting Threading, Transportations Etc. If Required And General Over Hauling Of Complete Pumps For Proper Completion Of Work. , Same As In No. 21 Above But For 30 Hp Pups Installed At Colony Filtration Plant. , Supply And Fixing Of The Following Starter L&T Or Other Equivalent Approved Make For Following Motors., 5 Hp Ml-1 , (7.5 Hp-10) Ml-2 , (15 Hp-20 Hp) Ml-2 , Above 20 To 25 Hp Ml-2 , Providing And Fixing Of Bush Of Approved Quality For 5 Hp To 15 Hp Pumps Including The Cost Of All Labour Involved For Opening Out & Re Fixing Of Bush In Pumps And T&P Etc. For Proper Completion Of Work. , Cleaning Of Over Head Tank 450 Kl Capacity Of 28 Meter Staging, Removing & Cleaning Of Silt Mud Sludge Etc, And Its Disposal At Ground With In 30 M Lead And Washing Inside The Tank Disinfecting The Bottom Surface And Walls Of The Tank With Water, Containing Bleaching Powder Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. , Same As Above In Items No.28 But For 100 Kl To 190 Kl Capacity Over Head Tank Of 15 To 20 Meter Staging , Same As Above In Items No.28 But For 50 Kl To 150 Kl Capacity Under Ground Water Tank. , Supply And Fixing Of Gland Plate For Upto 10 Hp Water Pump Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. , Repair Of Starter For Electric Motor, Opening Out , Choking , Changing Its Oil, Minor Parts Such As Nut, Bolts, Washer, Damaged Contacts And Other Parts Required Including Of All Material, T&P Etc. Required For Proper Completion Of Work.(Cost Of Relay Sale Be Paid Extra As Per Actual) , Providing And Fixing (150 Mm Dia To 200 Mm Dia) Non Return Value (Nrv) Isi Make Of Approved Quality Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work.(With Minimum 6 Months Guarantee.) , Providing And Fixing Brass/Gunmetal Impeller For 30 Hp Vlt/Turbine Pump Installed At Filtration Plant In Colony Area As Per Details Given Below And As Per S Le. Including Supply Of All Material Like Seal Ring Lock Vollet , Bearing Coupling , Bush Packing, Nut, Bolt And All Other Material, T&P Etc. Required For Proper Completion Of Work. Make Warthanth/ Jonston /Jyoti, Capacity 180 M3 /Hr , Speed 1460 Rpm Head , 30 M) , Providing And Fixing Of Impeller For The Following A.C. Mono Block Pumps Of Kirloskar Or Other Approved Make Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. 5 Hp To 7.50 Hp , 10 Hp To 15 Hp , Providing And Fitting The Following Items Upto 15 Hp Ac Mono Block Pumping Set All Material, T&P Etc. Required For Proper Completion Of Work With Pvc Cooling Fan Of Approved Quality. , P/F Key Way Of Coupling , Re-Metallising Of Bearing Seat On Rotarshaft And Machining , P/F Terminal Plate. , P/F Cooling Fan Cover Of Motor. , P/F Terminal Box Of Motor. , Replacing Of Set Of Main Contact Of Starter (L&T) Make Of Isi Mark Including The Cost Of All Labour, Material And T&P Etc. Required For Proper Completion Of Work. , P/F Of Condenser Of 45 Mfd Isi Mark For 2 H.P. Single Phase 230 V.A.C. Starter. , Repairing Of Following Sluice Valve Including Opening Out And Refixing Of Sluice Valve Accessories Such As Nut, Bolt, Glane, Repaired Spendil Etc. Including The Cost Of Machinery Arrangement, Nut, Bolt, Packing Etc. All Complete.(Min. Three Months Guaranty) Filling Required Type Of Metal Over Spindle And Gutka For Spindle And Machining Cutting Threading Over Spindle Its Clearing Of Rod On Lath Machine And Gutka Fixing In Spendil Etc. Or Replacement With New One (Old Material Will Be Property Of Contractor) And Re-Fixing Of All Accessories Including All Cost And Labour Material, T&P Etc. Required For Proper Completion Of Work.80 Mm Dia , 100 Mm Dia , 150 Mm Dia , 200 Mm Dia , 250 Mm Dia , 300 Mm Dia To 400 Mm Dia , Filling Required Type Of Metal Over Sluice Valve Seat Both Sides Including Cutting , Grinding, Welding , Fixing , Of Nut , Bolt, Washer In Sluevalve If Required Including Of Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of Work.80 Mm Dia , 100 Mm To 125 Mm Dia , 150 Mm Dia To 250 Mm Dia , 300 Mm To 400 Mm Dia , Providing Cotton Mosquito Proof Net Covers To Water Beds Of Filter Plant Of Size Approximate 6.20X4.0X0.90 M Doubly Stitched From Inside And Outside With Minimum 25 Mm Wide Cotton Strip Including Cost Of Material Labour, Cartage, Taxes T&P Etc. Complete. , Hiring Charges Of Breaker Including Cost Of Tractor,Operator Deisel ,Lead Upto 50 Meter And All T&P Required For Execution Of Work. , Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 25 To 40 Mm Nominal Bore , 50 To 80 Mm Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc External Work, 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , 125 Mm Dia , 150 Mm Dia , Same As Above In Item No. 5 But Without Excavation, 15 Mm Dia , 20 Mm Dia , Providing & Fixing Of G.I. Reducing Socket For ‘B Class Pipe Of Following Dia Including Supply Of All Material, Labour T&P Etc. Complete. 20 X 15 Mm Dia , 25 X 20 Mm Dia , 50 Mm To Any Smaller Size , 65 Mm To Any Smaller Size , 80 Mm To Any Smaller Size , 100 Mm To Any Smaller Size , Dismantling G.I. Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually/ By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer-In-Charge, 15 Mm To 40 Mm Nominal Bore , Above 40 Mm Nominal Bore , Supply And Fixing Of G.I. Tee For Class B Pipe Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete. 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , Supply And Fixing G.I. Bend/Elbow Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete. 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes;75 Mm Diameter , Same As Above But 110 Mproviding And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes;110 Mm Diameterm Outer Dia , Providing And Fixing 110X25 Mm Outer Dia Pvc Saddle Or 110 Mm Outer Dia Pvc Including Rubber Ring Including All Excavation, Refilling The Trenches Including Cost Of All Material Labour T&P Etc. , Providing And Fixing Pvc Flange Tail Piece For 110/90 Mm Outer Dia Pvc Pipe Line , Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertions Etc. (The Tail Pieces If Required Will Be Paid Separately) :100 Mm Diameter Class I , 150 Mm Diameter Class I , Providing And Fixing G.I. Union In Existing G.I. Pipe Line, Cutting And Threading The Pipe And Making Long Screws Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required : 15 Mm Nominal Bore. , 20 Mm Nominal Bore. , 25 Mm Nominal Bore. , 50 Mm Nominal Bore. , Repair Of Leakage In G.I./C.I./M.S./Pvc Pipe Line Of 20 Mm Dia To 200 Mm Dia Including Necessary Excavation Dismentalling And Relaying Of Pipe And Refilling Of Trenches Also Including Supply And Replacement Of Nuts/Bolts Washes Socket Flange Tail Piece, Spun Yard Safeda Welding Etc. Complete. 20 Mm Dia To 40 Mm Dia Pipe Line , 50 To 125 Mm Dia , 150 To 200 Mm Dia , Repair Of Reflex Valve By Removing It From Pipe Line Or Section And Of Pumping Set From Any Tube Well Opening Its Nuts And Bolts Replacing The Rubber/Leather Washer Making It Water Tight By Lightening Of Nuts And Bolts Reerecting/Refixing The Same In Pipe Line On In Tube Well Suction And Including Cost Of Job For Diameter Ranging From 100 Mm To 200 Mm Dia Including Taking Out Suction Pipe Of Required. , Supplying And Fixing Of G.I. Tee For Class B Pipe Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete.40X40x15/20 Mm Dia , 50X50x15/20 Mm Dia , Providing And Fixing 100 Mm Dia C.I. N.R.V. I.S.I. Marked Approved Quality Including Cost Of Al Labour, T&P Etc. Required For Proper Completion Of Work , Supply Of D Joint Of Following Dia Including Cost, Cartage Etc. Complete. 65Mm To 80 Mm Dia , 100 Mm Dia , 150 Mm Dia , Dismantling Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50Metres Lead As Per Direction Of Engineer-In-Charge : Water Bound Macadam Road , Bituminous Road , Cleaning Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) : 25 Mm Nominal Bore , 50 Mm Nominal Bore , 65 Mm Nominal Bore , 80 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete,15 Mm Nominal Bore , 20 Mm Nominal Bore , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5M, Disposed Earth To Be Levelled And Neatly Dressed. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) , Providing And Fixing Brass Stop Cock Of Approved Quality Weight Not Less Than 400 Gram. 15 Mm Nominal Bore. , Attending To Petty Maintenance Services Like Plumbing, Welding, Carpenting, Mason With One Carpenter Plumber Or Mason And One Helper Per Hour , Dewatering By Pump Of Capacity 5/7.5 Hp With 4 Meter Sump And 50 Meter Pump Length Including Installation, Operator/Helper, Desiel/Fuel Etc As Per Direction Of Engineer In Charge.
Contract Date: Ref. Documents Contract Value : 36.48 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
47.
Water Resources and Irrigation #11236109 Price Bid
Tender for Repairs To 6 Cusec X 15 Mtr Head Horizontal Split Casing Pump Of Unit-Iii Along With Allied Mechanical And Electrical Works At Lift Irrigation Station Jandi Nud , Dismantling Of 6 Cusec Horizontal Centrifugal Pump Coupled With 50 Hp Motor Of Unit No-Iii At Lis Jandi Nud By Way Of Decoupling The Motor From The Pump Shaft By Removal Of Nuts And Bolts Of Pulley Set. Dismantling The Pump From The Base Frame ,Suction Pipe Line And Delivery Pipe Line. Shifting The Pump And Coupling Pulley Set From Lis To Nearest Road Site By Head Load And Carriage To Work Shop In Mechanical Transport For Repair. Dismantling And Extraction Of All Worn Out/Damaged Parts I.E. Pump Shaft, Impeller, Bearings, Sleeves, Bush, Check Nuts, Nuts & Bolts, Gland Plate, Gland Studs. Properly Cleaning The Internal Surface Of Pump Casing. Remetalling /Brazing Of Pump Shaft And Turning To Bearing Size And Threading At Positions Of Check Nuts. Repairs To Impeller By Filing Cavities, Cracks And Finishing To Original Size. Providing And Fitting 2 NoS Of New Bearings On Driving And Non Driving End Of The Pump, 2 NoS Neck Rings, 2 NoS Shaft Protection Sleeves, 1 NoS Check Nuts, Nuts & Bolts, Fabrication Of 2 NoS New Gland Plate With Providing And Fitting Of 2 NoS New Gland Studs On Ends Of Pump. Repair To Bearing Housing On Non Driving End Of Pumping Unit By Providing And Fitting Of Bush, Turning And Fitting Of Bush To Make Inner Diameter Of Bearing Housing Suitable For Fitment Of Bearing. Reassembling All Parts Of Pump With Proper Greasing Of Bearings And Providing And Fitting Of Gasket Sheet Between Upper And Lower Part Of The Pump. Providing And Fitting Of Graphite Packing Of Suitable Size On Both Ends Of Pump. Then Back Carriage Of The Pump In The Pump House After Carrying Out Necessary Repair. Job Also Includes Replacement Of Damaged Motor Leads Of Motor Terminal Box By Way Of Supplying And Installation Of New Heavy Duty Insulated Copper Leads Suitable For 50 Hp Motor Of Unit No. Iii . Re-Installation Of Pump In Proper Alignment With 50 Hp Motor. Providing Of All The Electrical Connections. Testing On Full Load At Site. Repair To 50 Hp Starter Of Unit No-Ii At Lis Jandi Nud By Way Of Extracting The Damaged Worn Out Parts. Repair To Tripping System By Brazing And Finishing Required Size, Providing And Fitting Of No Voltage Coil, Overload Relay, Moving And Fixed Contact Point. Replacement Of Worn Out Thimbles Nuts-Bolts And Internal Leads Duly Soldered Properly. Topping Up Of Ats With 10 Litres Transformer Oil. Reassembling The Same At Site. Repair To 250 Mm Foot-Valve Of Unit No-Iii By Providing And Fitting Of New Flapper Plate With Hinges, New Inter-Mediate Plate, New Set Of Nut-Bolts, Leather Washers . Re-Assembling The Same And Installation At Site And Testing. The Job Also Includes Electrification Of Pump Room Building By Using Standard Quality Materials As Per Site Requirement For Lightening And Power Circuits By Wiring Of Approximately 70 M Length For Various Light And Power Points, providing and Fixing Of 3 No. Led Light Points/Lights (15 Watts) Inside Pump Room. Job Includes Fitting Of 1 No. Flood Light Of 50 Watts Of Reputed Make Outside Pump Room For Illumination Of Approach Path And Lis Area. Complete Job. Note: The Tenderers Are Requested To Visit The Site And Quote The Rate As Per Site Conditions. Any Modifications/Alterations Of The Job Felt Necessary If Required At The Time Of Actual Execution May Be Done As Per Actual Site Conditions. The Firm Should Offer Rebate On Old Material. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
49.
Power #11223257 Technical Bid
Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
TenderDetail
Loading tenders