View Bid Results For Rust Converter Tenders

We found 104 Bid Results related to rust converter tenders. You can find Contractor details who won rust converter tenders along with contract details in Bid awards announcements section.

Filters
Stage
96
5
3
Tender Publishing Platform
62
42
State / UT
22
15
11
10
9
6
5
5
5
4
4
4
4
4
3
3
2
2
2
2
2
1
1
Contract Value
31
29
31
13
Publish Date
0
0
0
0
0
Sector
17
28
20
11
10
9
7
4
3
2
2
2
1
1
1
1
1
1
Ownership
4
62
24
14
4
Within keyword
Active filters:
Showing 1–3 of 104 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 94,048
Government Departments No of Bidders 4
West Bengal View Result →
5.
Educational and Research Institute #11161433 Price Bid
Procurement Of Equipment, Instruments, Machinery, Tools Etc. Related To Laboratories And Workshops Of Electronics And Telecommunication Engg., Engineering Physics, Engineering Mechanics Of Mirik Government Polytechnic, Mirik, Dist. Darjeeling, 734214 , Spherometer (Screw Pitch 0.05 Mm And Lc 0.005 Mm) , Concave Mirror (Focal Length 20 Cm) , Convex Mirror (Focal Length 20 Cm) , Concave Surface (Focal Length 20 Cm Diameter 50 Mm) , Hooks Law Apparatus (Consisting Of 30 Cm Long Mirror Scale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand) , Mercury (Distilled Liquid Mercury, Grade Std.-Biotech Grade) , Flywheel Apparatus (Thickness: 4.4 Cm Diameter :20 Cm) , Cantilever (Length 100 Cm, Hook At One End, C Clamp) , Light Weight Hanger (Metal Slotted Weight Mechanics Physics Experiment Equipment Set With Hook With Weight Of Each Mass Of The Order Of 50Gm Or 100 Gm) , Inverse Square Law Apparatus (Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter) , Stopwatch (Digital Stopwatch With Ms Count) , High Resistance Box (Resistance Box Plug With 1 To 10 K Ohm Resistance) , Winch Crab Single Purchase With Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut.String, Weight Box With Pan. ] , Winch Crab Double Purchase Without Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut. ] , Worm And Worm Wheel Single Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Worm And Worm Wheel Double Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Wheel & Axle Simple Without Weight [Standard Setup For Lab.] , Simple Screw Jack With Weight [Experiment Set Up Screw Jack ( Weights)All Metallic Construction Accurately Machine Cut Screw With A Pitch Of 5 Mm Carrying A Double Fanged Turn Table Of About 20 Cm Diameter. Fitted On A Heavy Cast Iron Base And Complete With Two Adjustable Pulleys, Cord And Hook. Weights Are Included.] , Combined Inclined Plane & Friction Slide Apparatus Iron Base & With Weight [Standard Setup For Lab.] , Parallel Forces Apparatus [Experiment Set Up Simple Supported Best Type Supported At Its End. For Verification Of Condition Of Equilibrium Of Parallel Forces, Law Of Lever & Forces On Beam Etc. Consisting Of Two Compression Thrust Type 10 Kg Tubular Spring Balances Fixed On Wooden Polished Board, A Wooden Beam With Steel Back Plate. Complete With Two Strups, Hooks & Two 10Kg Weights. ] , To Verify Lami’S Theorem [Gravesand Apparatusboard: Wooden With Metal Base Pulley: Z-Pullies (2 Nos) With Adjustable Distance Weight Set: 5X50 G (3 Sets). ] , Simple Jib Crane Apparatus Iron Stand With Weight [Experiment Set Upwith Consisting Of A Tubular Compression Balance, Pivoted About An Axis Fitted To The Base. The Tie Chain Has An Adjustable Angle Bracket And Fitted With A 10Kg Extension Balance. Completion Wooden Base With 1.2 Meter Jib. With Weights. ] , Mini Drafter, T Square, Protractor, Set Squares, Compass, Divider [Made Out Of Wood. To Be Used In Chalk Board] , Model Of Geometric Constriction (Solid Cube, Solid Primed, Cylinder, Cone, Hexagon, Tetrahedron ) [Made Out Of Wood. To Be Used In Chalk Board] , Amplitude Modulation And Demodulation Trainer Kit [Message Signal:100 Hz To 2.8 Khz, Carrier Signal 28 Khz To 108 Khz,Modulation : Balanced Modulator, Amplifier : Op Amp Based, Demodulation : Diode Detector & Lpf(6Th Order)] , Frequency Modulation Anddemodulation Kit [On-Board Message Signal With Variable Amp/Freq,On Board Carrier Signal Fm Modulation Using Xr 2206Ic,Demodulation Using Pll Detector And Lpf 4Th Order Lpf,Internal Power Supply +5V , +12V/ 500 Ma] , Super Heterodyne Am Radio Receiver Trainer Kit To Measure Sensitivity, Selectivity And Fidelity [On Board Variable Capacitor Tuning,Receiving Antenna,Local Oscillator,Bfo, Rf Amplifier, Mixer,If Amplifiers, Detectors, Agc,Audio O/P Amplifier, Speaker.Frequency Range: 400Khz To 1700Khz,If Frequency: 455 Khz.] , Pam, Pwm And Ppm Modulation And Demodulation Trainer Kit [Provides Sine Waveform Output Of 250Hz, 500Hz, 1 Khz, And 2 Khz With Amplitude Adjustments Of 0 - 5Vp-P. Switch Selectable Sampling Clock Of 4, 8, 16, 32 Khz. On-Board Features Analog Sample Circuit/Output, Sample & Hold Circuit/Output, Flat Top Circuit/Output, 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz.] , Analog Signal Sampling & Reconstruction Trainer Kit [±15V D.C. At 100Ma, Ic Regulated Power Supply, A.F. Signal Generator For Modulating Signal.Sampling Clock Generator To Provide Sampling Clock And Gate Pulse. Modulator Circuit For Flat-Top Natural And S/H Circuit. Demodulator Circuit To Reconstruct Input (Sinewave)] , Telephone Receiver Trainer Kit [Line In Section : One Dot Line Connection Port.Handset : One Handset Connection Port. Keyboard : 4X3 Matrix Keyboard.Dialer : Tone And Pulse. Facilities : Redial Up To 32 Digits, Mute, Redial, Flash, Pause Switches.Indicators : Line In, Hook, Tone And Ringer, Call Mute Section.Control : Ringer Volume Control, Ringer Speed Control.Speech Path : Fully Non-Blocking.Dial Pulse Ratio : 10 Pps + / - 10%.] , 100Mhz Digital Oscilloscope [Bandwidth: 100 Mhz, 2 Analog Channels+ Ext With Probes Included Rise Time: =3.5 Ns, Real-Time Sample Rate Of 1 Gsa/S 1% Dc Gain Accuracy Should Support Rs232/Uart, I2c And Spi Bus Triggers And Decodes Usb And Ethernet Connectivity] , 30Mhz Analog Cro [Dual Trace Dual Channel Oscilloscope. Bandwidth: 20Mhz. Full Bandwidth Sweeping Circuit , Tv-H / Tv-V Synchronization And Trigger-Lock To Observe All Kinds Of Signals Stably. Y Deflection Operation: Y1, Y2, Alt, Chop, Add, Mode.Horizontal Sweep Mode: Auto, Trig, Lock, Single.X-Y Mode Input: X-Axis Yi And Y-Axis Y2.] , 2 Mhz Function Generator [Frequency: 1Hz – 2 Mhz Sine, Square, Triangle, Ttl Output] , Digital Storage Oscilloscope (100 Mhz) [Bandwidth 100 Mhz, Channels: 2+, Display: Tft Color Lcd Of Suitable Size (Capacitive Touchscreen). Sampling Rate: 1 Gsa/S Real Time, Sampling Mode: Normal, Average (2, 4, 8, 16, 32, 64, 128, 256), Peak Detect. Mathematics: A+B, A-B, A×B, Fft (Fast Fourier Transform). Fft Windows: Rectangle, Hanning, Hamming, Blackman. Auto Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1-2 (Rise), Delay1-2(Fall) ] , Trainer Kit For Rectifier With And Without Capacitor Filter For : — (A) Half-Wave Rectifier, (B) Full-Wave Rectifier, (C) Bridge Rectifier [Transformer Rating : 9-0-9V/200Ma, Rectifiers : Half Wave; Full Wave - Bridge, Center Tapped Rectifier,On-Board Dc Voltmeter : 0 - 20V,On-Board Ac Voltmeter : 0 - 20V,Load : Variable Resistive Load 10K,Filter Circuit : In-Built- Capacitor (3Nos.),In-Built- Inductor (1No.),Input Line Voltage : 230V Ac ± 10%, 50Hz] , Push-Pull Amplifier Trainer Kit [I.C Regulated Power Supply : +6 V.Digital Ac Voltmeter: 0 – 20 V.Digital Ac Milliammeter : 0 – 200 Ma.Set Of Resistances.Set Of Capacitors.Two Transistors Cl 100 And Ck 100.Connecting Wire.] , Fet Characteristics Trainer Kit [Variable Dc Regulated Power Supply Of 0-5V At 250Ma. Dual Range Dc Voltmeter Of 1.5V/15V.Dc Ammeter Of 0-20Ma.] , To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Bandwidth, Midband Gain, Input Impedance And Output Impedance For: (A) Single-Stage Amplifier (B) Double-Stage Amplifier [Sine Wave Oscillator 15Hz To 150Khz In Four Ranges With Amplifier & Amplitude Adjustable.Three Decade Resistances Bank In Steps Of 1K, 10K & 100K Per Steps Total Step 30.Two Pnp Transistors.] , Mosfet Characteristics Trainer Kit [On Board Ammeter And Voltmeter,Dual Variable Dc Power Supplies,On Board Mosfet And Fet With Resistors To Perform Experiments] , To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — (A) C-E Configuration, (B) C-C Configuration, (C) C-B Configuration [Power Supply 1) 0-1V Dc 2) 0-10V Dc.Meters Dc 65Mm Four Dial V, V , Ma Ua/ Ma.Transistor Cl100/ Similar] , Component Development System [Power Supplies On Boards 0-15 V And 0-30 V, 250 Ma Each Variable.Fixed Dc Regulated Power Supplies 15 V/250 Ma And 5 V/250 Ma.Ac Power Supply 15-0-15 V For Rectifier Applications.Various Components On The Trainer Set. ] , Kcl & Kvl Trainer Kit [Two Dc Ic Regulated Power Supplies 0-12 V/150 Ma, Two Mr65 Square/Digital Meters For Voltage & Current Measurement, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Power Cords 230 V, 50 Hz] , Thevenin’S And Norton’S Theorems Trainer Kit [Power Supply 2?3?0?V, Regulated & Short Circuit Proof Variable Dc Voltage Source – 01 No. Fixed Resistance Of Different Values. Dc Voltmeter.Dc Ammeter. Glass Fuse For Short Circuit Protection. On/Off Switch With Indication Light. Patch Cords Suitable To The Terminals With Board For Easy Interconnection.All Above Accessories Will Be Fitted On Bakelite Sheet Fixed On Box.] , Superposition Theorem Trainer Kit [Instrument Comprises Of Two Fixed Output Dc Regulated Power Suppliesof 12V & 5V At 500 Ma Current, Three Moving Coilmeter, Circuit Diagram Printed On The Front Panel & Connections Ofsupplies, Meter & Resistances Brought Out At 4Mm Sockets. ] , Maximum Power Transfer Theorem Trainer Kit [Ammeter 30Ma Dc. Voltmeter 12V Dc. Power Supplies: Dc Supply Ic Regulated 0-12V Dc, 150Ma. Operated On Mains Power 230V, 50Hz +10% Components Are Mounted On The Panels Are: Resistances 2Watts Variable Resistor Voltage Control Through Potentiometer. Fuse For Short Circuit Protection. Patch Cords 4Mm.] , Reciprocity Theorem Trainer Kit [Instrument Comprises Of One Fixed Output Dc Power Supply Of 12V At 300 Ma Current, Two Moving Coil Meters, Circuit Diagram Printed On The Fornt Panel & Connections Of Supplies, Meters & Resistances Brought On Terminals.] , Series And Parallel Resonant Circuit Trainer Kit [Analog Meters: Ammeter 20Ma Ac. Voltmeter 20V Ac. Components Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch.] , Low Pass And High Pass Filter( Rc & Lc) Constant K Type Trainer Kit [Instrument Comprises Low Pass Circuit Rc Type Instrument Comprises Low Pass Circuit Lc Type Instrument Comprises High Pass Circuit Rc Type Instrument Comprises High Pass Circuit Lc Type Instrument Fitted In Highly Shockproof Plastics Box] , T And ? Type Attenuator Trainer Kit [Instrument Comprises Ofdc Ic Regulated Power Supplies 0-15V/150Ma. Two Mr65 Square / Digital / Round Meters For Voltage & Current Measurement. T And Pie Network Provided On The Board. Variable Resistor Using Band Switch Is Mounted On The Board. Instrument Fitted In Highly Shockproof Plastics Box. Sufficient No Of 4Mm Patch Cords For Interconnection Instruction Manual For Student Workbook. Power Cords 230V, 50Hz] , To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: (A) Open Termination, (B) Short Termination, And © Matched Termination. [Transmission Line : Coaxial Cable 100M ( 25M X 4 Nos) Impedance Matching Resistance : 0 To 100 ( 02 Nos ) Test Generator : 1. Sine Wave : 4 Khz To 4 Mhz. 2. Square Wave : 10 Khz. Interconnections : 4 Mm Sockets On All Input / Output Connections. Test Points : 10 On Board Circuit Mimic : Illustrates Functional Blocks For Ease Of Experimentation Power Requirement : 230V 10% 50Hz, 1 Ac. Accessories Provided : I. Set Of Patch Cords. Ii. Bnc To Bnc Cable. Iii. Bnc To Crocodile. Iv. Detailed Instruction Manual.] , Digital Trainer Kit (Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor.) [Dc +5V , 400Ma; Dc +12V, 250Ma; Dc -12 V, 250Ma, Dc0 To + 30V: Variable 100Ma,Ac Output: 12V-Ct-12V, 150Ma; Logic Data 8-Bit Debounced Set/Clear Ttl Output With Bicolour Led; Clock Generator I Hz To 200Khz Variable & Manual, Ttl & /Ttl(Complement) With Bicolour Led;Logic Probes 8-Bit 3-State Led Display High, Low, High Impedance; Function Generator Sine, Square, Triangle, 1 Hz To 250 Khz;Bread Boards : 3 X 820 Tie-Points; Total Short Circuit Protection From Any To Any Point On Board] , Complete Setup To Implement The Truth Table Of Encoder,Decoder, Multiplexer And De-Multiplexer. [The Trainer Kit Should Be Able To Verify The Truth Tables Of Truth Table Ofencoder,Decoder, Multiplexer And De-Multiplexer.] , Complete Setup To Design/Construct Parity Generator, Checker And Comparator. [Industry Standard Specification To Perform Relevant Experiments. ] , Flip Flop Trainer Kit [Kit For Verification Of Jk, Sr, D, And T Flip-Flop Truth Tables] , Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design / Construct Programmable Up/Down Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design Controlled Shift Register And Study Their Function. [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Study Different Memory Ics [Industry Standard Specification To Perform Relevant Experiments. ] , A/D & D/A Converter Trainer [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Interface Ttl And Cmos Ics. [Industry Standard Specification To Perform Relevant Experiments. ] , 8051 Trainer Kit [Operating Frequency : 10Mhz Crystal,40-Pin Ic Base | 40Pin-Zif Socket,2×16 Char Lcd Display,32 I/O Pins,32Kb-Sram,32Kb-Eeprom.] , Ct-31/51 Or 8031/51 Microcontroller Trainer Kit With Led Display, Usb Interface & Inbuilt Power Supply [Operating At 10/12 Mhz, On Board 8K Ram,8/16K Bytes Of Eeprom,48 I/O Lines,Hexadecimal Keyboard And Six Seven Segment Displays,Rs-232C Interface,Usb Interface] , Ct-31/51Lcdadu8031/51 Microcontroller Trainer With Lcd Display, Usb Interface, Adc, Dac& Inbuilt Power Supply [Trainer Based On 8051/89C52 Microcontroller.On Board 32K Ram.64 K Bytes Of Eeprom.20 X 2 Lcd Display.48 I/O Lines. Onboard Adc & Dac.] , Adc Interface Module [Usb Interface, Adc Module Module 10 Channel 12Bit Ad Sampling Data Acquisition Stm32 Uart Communication Adc Module] , Dac Interface Module [Operating Voltage 2.7-5.5 V. Interface Type I2c. Resolution 12 Bits.] , Lcd Display Module [Display Contents :16 * 2 Characters (5*8 Dots ). Lcd Size :80 X 36 Mm .Lcd Thickness :9.5 Mm.] , Keyboard Interface Module [5X4 Keys Matrix Keyboard. ] , Dc Motor Controller Module [Driver Module : L298n. Motor Supply Voltage (Max.): 46V.Motor Supply Current (Max.): 2A. ] , Stepper Motor Controller Interface Module [Robocraze Stepper Motor(28Ybj-48 Dc 5V 4 Phase 5 Wire) + Uln2003 Driver Board Compatible With Arduino] , Trafic Light Controller Module [Led Traffic Lights Signal Module/Digital Signal Output Traffic Light Module] , Temperature Measurement Module [Electrobot Dht11 Digital Temperature & Humidity Sensor Module For Arduino And Rpi] , Operational Amplifier Trainer Kit ( Ic 741 ) [Inbuilt Variable/Fixed Dc Regulated Power Supplies.Output Voltages : 0-5Vdc (2Nos.) (Variable), +12Vdc (Fixed).Transistor & Components Provided Ic : 741.Transistor : Cl 100 (Npn).] , Active Filter Trainer Kit (Lpf, Hpf, Bpf) [Opamp Based First Order Lpf, Hpf, Bof Trainer Kit (Mi-A14)] , Application Of Ic555 Timer Trainer Kit (Astable & Monostable Mv) [In-Built Regulated Dc Power Supply.On Board Manual Pulse Generator For Triggering The Monostable And Bistable Circuit.Inbuilt Led Output Indicator.Symbols And Diagram Are Printed On Glass Epoxy Pcb.] , Opamp Based Oscillator Trainer Kit ((A) Hartley, (B) Colpitt, (C) Phase Shift, (D) Wein Bridge) [Op-Amp Oscillator Trainer Mi-A13. Frequency 50-60 Mhz.] , Crystal Oscillator Trainer Kit (741 Based) [Industry Standard Specification To Perform Relevant Experiments. ] , Function Generation Kit (Using Icl8038) [Icl8038 Function Signal Generator Sine Triangle Wave Kit Diy Professional K5e8.Uses Icl8038 And High-Speed Op Amp, Higher Accuracy. Low Distortion Sine Wave: 1%.] , Voltage Regulator Trainer Kit (Using Ic723) [0-35V D.C. At 250Ma, Countinously Variable Unregulated Power Supply.D.C. Milliammeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 50Ma And 250Ma.D.C. Voltmeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 10V And 40V.Ic 723 Fitted On Base.Three Potentiometers.] , Function Generator Trainer Kit [Frequency Ranges: 1? Hz To 1?0? Hz, 1?0? Hz To 1?0?0? Hz Fuse:3?5?0? Ma, Slow Blow Automation Grade: Manual Power Supply:Max 2?3?0?V Ac, 5?0? Hz +/- 1?0?%] , Maxwells Bridge Trainer Kit [The Kit Contains A Bridge With Provision For Connections Of Capacitors And An Unknown Inductor. In Built Ac Supply [ 1 Khz And 2 Vpp ] And Dc Supply [ +5 V ] On Board. Two Nos Dial Resistances [ 50 Ohm To 200 Ohm ] And [ 1 Ohm To 11 Ohm ] In Step. A Dc And Ac Null Detector Using Selector Switch. A Dial Type Variable Capacitor [ Range 0.2 Uf Ro 1.2 Uf ] And Six Nos. Unknown Inductors [ Range 1 Mh To 12 Mh ].] , Lvdt Trainer Kit [Excitation Source Built In Ac Source 2.5 Khz Sine Approx. L.V.D.T. In Non Metallic Structure. Micrometer One (For Displacement) Displacement Range 10Mm. Test Points Sockets At Different Places For Signals. Potentiometer Two For Zero & Calibration Adjust Display (Mm) 3.5 Digit Digital Power Supply Ic Regulated Phase Detection Balanced Demodulator Power Supply Short Circuit &Overload Protected Mains 230V/50Hz Ac] , Strain Gauge Trainer Kit [Strain Gauge: 4 Mounted Upon Cantilever 150X3.5X3.5Mm, Stable Dc Voltage For Strain Gauge Bridge, Opamp Based,Precision Instrumentation Amplifier With Variable Gain,Potentiometer For Zero And Calibration Adjust,3.5 Digit Display For Strain/Weight, 230V 50Hz Ac] , Temperature Transducers Kit Using (A) Rtd (Pt-100) (B) Thermistor. [12 - 0 - -12 V 500Ma To Drive Digital Integrated Circuitry. 5 - 0 - -5 V 250Ma To Drive A To D Converter Signal Conditioning And Amplifying :Analog To Digital Converter. Display : 31/2 Digit Led Display Of 200 Mv Fsd Initial Set : Single Turn Potentiometer To Set Initial Temperature ( Room Temperature) Final Set : Single Turn Potentiometer To Calibrate The Instrument ( Max. Temperature) Select : 2 Way Rotary Switch To Select Rtdand Thermistor. Power On : Rocker Switch To Control Power Supply To The Instrument.] , Calibration Of A Single-Phase Energy Meter By Phantom Loading Trainer Kit [Usage/Application: Lab Experiment Connection:4?-Mm Patch Cord Single Phase Automation Grade:Manual Power:2?0?0? W Voltage:2?2?0?-2?4?0? V] , Calibration Of A Voltmeter Using Crompton Potentiometer Trainer Kit [This Trainer Is Supplied Along With Highly Regulated Dc Power Supplies To Operate The Unit. Further To Calibrate Pmmc Meters, Necessary Ratio Boxes Also Provided. Resistors Used In This Unit For Coarse And Fine Are Very Standard Type Made Of Manganin. This Enable The User To Measure The Potential In A Circuit Close To Micro Volts. Necessary Schematic/Wiring Diagram Printed On The Panel To Follow And Conduct Experiments. User Manual And 4Mm Patch Cords Supplied. Accessories Included: Necessary Dc Power Supplies, Ratio Boxes & Galvanometer Are Provided Alongwith The Unit.] , Cro Demonstration Kit [Crt : 6Rectangular Screen With Internal Graphical 8X10 Division (1Div-1Cm) Vertical Deflection Display : Ch1, Ch2, Add, Alt & Chop Deflection Factor : 5Mv/Div To 5V/Div +3%, 1Mv/Div To 1V/Div, +5% (X5), 10 Steps Rise Time : <17.2Ns Maximum Input Voltage : 250 (Dc + Ac Peak Value) When <1Khz (250V, Dc +Ac) Input Coupling : Ac, Dc & Gnd Polarity Selection : + (Ch2 Only) Display Mode : 1, 10 & X-Y Horizontal Deflection Time Base : 0.2Us/Div To 0.2S/Div, 9 Ranges Sweep Expansion : X10 Accuracy : +3% Triggering Mode : Auto, Norm, Tv-V, Tv-H Triggering Source : Int, Line & Ext. Trigger System Auto : 20Hz-20Mhz Norm : 0.5 Div Int, 0.5 Vp-P Ext Tv-H : At Least 1 Div Or 1 Vp-P Input Impedance : 1Mohm X-Y Phase Difference : <3 Degree, Dc-50 Khz Calibration Waveform : Frequency 1Khz 2%,Voltage 0.5 V 1%, Block Diagram Printed On The Top Panel, Power Requirement: 220 Vac +10% , 50 Hz] , Q-Meter Kit Formeasurement Ofq Of Coils. [Inductance Range:199.9Mµh-19.99H Resistance Range (Ohm):19.99O-19.99M? Capacitance Range:199.9P-1.999?F Capacitance Accuracy: ±(1%±2) Digital Lcr Bridge Meter Power:220 Volts/50Hz ±10%] , Spectrum Analyzer Trainer Kit [Industry Standard Specification To Perform Relevant Experiments. ] , Public Address System Trainer Kit [To Test The Performance Of Loudspeaker And Microphone; Power Output: 100W Rms At 10% Thd Pre-Amplifier Output: 200Mv; Line Output: 1V/ 1K?; Input Channels: Mic: 2Nos; Frequency Response : 65 Hz To 15 Khz +/- 3Db Tone Controls : Bass, Treble, Master 1Control; Speaker Outputs : 4 , 8 , 16 , 70-100V Line Matching; Speakers : 2 Nos; Microphones : 2 Nos(Dynamic Microphone)] , Demonstration Kit Of Black & White Tv Trainer [To Learn The Practical Aspects And Faults Which Would Occur Often In The Black And White Tv. All The Fault Switches Are Provided To Conduct Fault And Observe The Output. The Test Points Are Provided To Determine The Voltages At The Different Sections Of The Tv And Observe The Signal Output Of The Various Sections. The Output Is Monitored On A 20” Picture Tube.] , Demonstration Kit Of Colour Pattern Generator For Colour Tv [They Should Be Able To Make Various Patterns, Including Vertical Bar Patterns, Horizontal Bar Patterns, Circle Patterns, 100% White Patterns, Check Patterns, Horizontal Bar Patterns, Vertical Bar Patterns, Color Bar Patterns, Red Color Patterns, Green Color Patterns, Blue Color Patterns,Yellow Color Patterns, Magenta Color Patterns, And Cyan Color Patterns. Learning Materials To Be Included: Theory, Procedure, Reference Results, Etc.] , Demonstration Kit Of Colour Led Tv Trainer [Display Type: Led; Hd Screen Size: 24 Inch (50Cm) Or More; Display Resolution: 1600 X 900 Pixels Or More; Video Interface: Video Input/ Vga, Hdmi And Or Dvi Input; Audio Output Power: 8W X 2; Receiving System: Pal Bg/I/Dk And Ntsc; Channel Coverage: Vhf-2-12, Uhf21-69; Catv (X~Z+2, S11s41) Mains Supply: 110-260V Ac ± 10%, 50/60Hz; Power Consumption: 35W] , Demonstration Kit Of Dth Trainer Kit [Colour Tft Lcd: 5.7” Tft Lcd; Rf Input: 950 - 2150 Mhz; Rf Output: 470 Mhz Two 862Mhz; Video Output: Pal/Ntsc; Uplink Satellite: Insat 4B; Test Points: 34 Nos.; Included Accessories: Mains Cord, Power Supply, Remote, Dish Antenna With Accessories, Lnb] , Demonstration Kit Of Photocopier [Interface Hi-Speed Usb 2.0 Copy Speed Simplex To Simplex Up To 20 Ppm In A4 (21 Ppm In Letter) Scan Method Color Cis Compatibility Twain, Wia Fault-Creating Facilities For Crum, Thermistor, Stepper Motor, Pickup Clutch, Feed Sensor, Width Sensor, Scanner Stepper Motor, Scanner Sensor, And Printer Door. Various Fault Switch With Test Points Provided On-Board.] , Demonstration Kit Of Fully Automatic Washing Machine Trainer Kit [Semi/Fully Automatic Washing Machine Mechanical Controls 30 Minutes Timer, Wash/Spin Control Atleast 6 Liter Capacity Machine Fault Switches For Wash Motor, Spin Motor, Lid Opening, Buzzer Etc All Faults Are Mounted On Pcb With Enclosure] , Demonstration Kit Of Microwave Oven Trainer Kit [Type: Solo; Capacity: >15 Ltr; Power Consumption: 600 Watt Or More: Child Lock And Alarm, Various Test Points] , Demonstration Kit Of Refrigerator [Industry Standard Specification To Perform Relevant Experiments. ] , Demonstration Kit Of Air Conditioner. [Industry Standard Specification To Perform Relevant Experiments. ] , Tdmpulse Code Modulation Trainer Kit [Crystal Frequency: 12/16 Mhz On Board Generators, 1. Adjustable Amplitude Sine Generator Of 500Hz & I Khz (Synchronised) 2. Variable Amplitude Dc Level (2 Nos.) Input Channels: Two Multiplexing: Time Division Multiplexing Modulation: Pulse Code Modulation Sync Signals: Pseudo Random Sync. Code Modulation Error Check Code: Off, Odd, Even, Hamming Operating Modes: Fast 240 Khz Channel (Approx) And Slow I Khz Channel (Approx) Pc - Pc Communication: 2 Channel Via Rs 232 Baud Rate: Selectable From 300 To 2400 Fault Switches : 8 Nos. Through 8 Way Dip Switch For Troubleshooting At Different Blocks Should Include Various Test Points] , Tdm Pulse Code Demodulation Trainer Kit [2 Channel Time Division Multiplexed Pulse Code Modulation Receiver. Fast (240 Khz/Channel Approx) And Slow (1Hz. /Channel Approx.) Mode Of Operation Pseudo Random Sync. Code Generator For Frame Synchronization. Receiver Clock Generation Using Pll. Error Detection Of None, Even, Odd, Hamming. Error Correction Using The Hamming Code Technique None, Even, Odd, Hamming Parity Selections Two Nos. Of 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz. Four Switched Faults For Fault Selection Block Description Screen Printed On Glassy Epoxy Pcb] , Fdm Transmitter / Receiver Kit [Two Variable Modulating (Sinusoidal) Input Channels With Provision Of Voice Inputs Two Dsbsc Modulators For Frequency Band Translation Of Two Test Signals Two Carrier Generators Two Sets Of Audio Input Amplifier One Adder/Transmission Amplifier Two Demodulators Two Low Pass Filters For Smooth Output] , Ask / Psk / Fsk Modulation And Demodulation Kit [The Kit Should Have An Integrated Ask / Psk / Fsk Modulation And Demodulation. Various Functional Block Diagrams Are Provided On-Board For Teaching/Training. Test Points To Visualize The Signals On Oscilloscopes] , Microwave Test Bench (Klystronbased) [Complete Klystron-Based Test Bench Study Of The Characteristics Of The Klystron Tube And To Determine Its Tuning Range, To Determine The Frequency & Wavelength In A Rectangular Waveguide Working On Te 10 Mode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , Microwave Test Bench (Gunn Based) [To Study The V-I Characteristics Of Gunn Diode, To Study The Voice Communication By Using Microwave Test Bench, To Study The Following Characteristics Of Gunn Diode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , 24 Awg Tinned Single Strand Jumper Wire Spool Blue Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Green Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Red Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Black Colour [90 Meter Spool] , Flexible Electric Wire [2 Core, Twisted Flexible, Red And Black, 0.5 Sq Mm Copper Core, 50M Length] , Soldering Wire [Flux Core, Coil Type (Wire Of 100Gm )] , Inductor 1 Mh [8X10 Mm Radial Leaded Power] , Inductor 10 Mh [8X10 Mm Radial Leaded Power] , Led Red, Green, Blue, White Colour. Fifty Numbers Of Each Colour Led. [0.5W, Through Hole Type] , Ic 7400 [Ttl Ic-Quad 2-Input Nand Gate] , Ic 7402 [Ttl Ic-Quad 2-Input Nor Gate] , Ic 7404 [Ttl Ic-Hex Inverter Gate] , Ic 7408 [Ttl Ic-Quad 2-Input And Gate] , Ic 7432 [Ttl Ic-Quad 2-Input Or Gate] , Ic 7486 [Ttl Ic-Quad 2-Input Xor Gate] , Ic 7474 [Ttl Ic-Dual D Positive Edge Triggered Flip-Flop, Asynchronous Preset And Clear] , Ic 7476 [Ttl Ic-Dual J-K Flip-Flop, Asynchronous Preset And Clear] , Ic 7490 [Ttl Ic-Decade Counter (Separate Divide-By-2 And Divide-By-5 Sections)] , Ic 7495 [Ttl Ic-4-Bit Shift Register, Parallel In, Parallel Out, Serial Input] , Ic 74200 [Ttl Ic-256-Bit Ram (256X1)] , Ic 74147 [Ttl Ic Encoder] , Ic 74138 [Ttl Ic 3 To 8 Line Decoder] , Ic74151 [Ttl Ic Multiplexer] , Ic74138 [Ttl Ic Demultiplexer] , Ic 74169 [Ttl Ic Up-Down Counter] , Ic 74180 [Ttl Ic Parity Checker/Generator] , Ic 74Ls83 [Ttl Full Adder With Carry Ic] , Ic 74330 [Ttl Ic-Pla (12 Inputs, 50 Terms, 6 Outputs)] , Ic 4077 [Cmos Ic Xnor Gate] , Ic 4001 [Cmos Ic Nor Gate] , Ic 4011 [Cmos Ic Nand Gate] , Ic 4070 [Cmos Ic Exor Gate] , Ic 4071 [Cmos Ic Or Gate] , Ic 4077 [Cmos Ic Ex-Nor Gate] , Ic 4081 [Cmos Ic And Gate] , Ic 4093 [Cmos Ic Nand Gate] , Ic74ls47 [Bcd To 7-Segment Decoder/Driver Ic (7447 Ic) Dip-16 Package] , Lts542 [7-Segment Display - Common Anode] , Lts543 [7-Segment Display - Common Cathode] , Ic Dac0808 [Dac0808 8-Bit Digital To Analog D/A Converter Ic Dip-16 Package] , Ic Adc0809 [Adc0809 8-Bit A/D Converter With 8-Channel Multiplexer Ic Dip-28 Package] , Ic723 [Voltage Regulator Ic Input Voltage Up To 40V Output Voltage Adjustable From 2 To 37V Positive Or Negative Supply Operation Series, Shunt, Switching Or Floating Operation Output Current To 150Ma Without External Pass Transistor Adjustable Current Limiting] , Icl8038 [Function Generator Ic Wide Frequency Range - 0.001Hz To 300Khz Variable Duty Cycle - 2% To 98% High Level Outputs - Ttl To 28V Simultaneous Sine, Square, And Triangle Wave Outputs] , Ad633 [Analog Multiplier Ic 4-Quadrant Multiplication Low Cost, 8-Lead Soic And Pdip Packages Complete—No External Components Required Laser-Trimmed Accuracy And Stability Total Error Within 2% Of Full Scale Differential High Impedance X And Y Inputs High Impedance Unity-Gain Summing Input Laser-Trimmed 10 V Scaling Reference] , Lm566 [Vco Ic Wide Supply Voltage Range: 10V To 24V Very Linear Modulation Characteristics High Temperature Stability Excellent Supply Voltage Rejection 10 To 1 Frequency Range With Fixed Capacitor Frequency Programmable By Means Of Current, Voltage, Resistor Or Capacitor] , Ic Ne555 [Ne555 Timer Ic Dip-8 Package, Pack(Set) Of 30 Ics] , Ic 741 Op-Amp (Dip) [741 Ic - Dip Package - General Purpose Op-Amp Ic, Pack(Set) Of 50 Op-Amps] , Transistor 2N3904 [Pack (Set) Of 20 Transistors] , Transistor Bc107b [Pack (Set) Of 20 Transistors] , Diode 1N4007 [Pack (Set) Of 50 Diodes] , Fet- Bfw10 [Pack (Set) Of 50 Field Effect Transistors] , Zener Diode 5.6V, 1W [Pack (Set) Of 20 Zener Diodes] , Potentiometer 1 K?, 10 K?,100 K? Power Rating: 1W [20 Nos Of Each Value] , Wire Stripping Pliers, 6 Inch Long [Stainless Steel, Rust Resistant.] , Long Nose Mini-Pliers [Stainless Steel, Rust Resistant.] , Resistor 33O, 56O, 68O, 82O, 100O, 120O, 200O, 220O, 270O, 330O, 390O, 470O, 680O, 1K?,1.5K?. Maximium Power Rating 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Resistor 2.2K?, 2.7K?, 3K?, 4.7K?, 5.6K?, 6.8K?, 8.2K?, 10K?, 20K?, 36K?, 56K?, 68K?, 100K?, 470K?, 1M?, 2M? Maximium Power Rating: 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Disk Ceramic Capacitor Of Values 220 Pf, 0.01 ?F, 0.024?F, 0.1?F, 0.24?F [Pack(Set) 25 Nos Of Capacitors For Each Valueh] , Disk Ceramic Capacitor Of Values 10?F(63V), 100?F, 220?F, 470?F(50V) [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Polypropylene Capacitor Of Values 0.001 ?F,0.01 ?F, 0.1 ?F, 0.22 ?F [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Tantalum Capacitor 10 ?F (25 V) [Pack(Set) Of 25 Capacitors] , Incandescent Bulb, 40W, 100W, 200 W [With Tungstenfilament And B22 Connector]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
West Bengal View Result →
6.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
7.
Power #10640145 Price Bid
Maintenance, Servicing, Calibration And Stamping Of2 Nos. 100 Tonne Capacity ‘Avery’ Make Electronic Weigh Bridge Installed At Ash Dyke Area For Wet Ash For The Period Of One Year; 1 Charges For Inspection And Servicing Of Control Panel, Indicator And Circuits Of 100 Ton Capacity Electronic Weighbridge With 8 Nos. Of Load Cells Installed In The Ash Dyke Area For Wet Ash Measurement. 2 Charges For Calibration & Obtaining Annual Statutory Stamping For The Weighbridge Installed In The Ash Dyke Area From The Assistant Controller Of Legal Metrology, Salem Inclusive Of Providing Necessary Assistance. 3 Charges For Dismantling The Monitor, Cpu, Printer And Other Allied System, Through Cleaning, Assembling And Putting Into Service And Checking The Computer System 2 Nos. Of The 2 Nos Weighbridge Systems. ( Two Nos. Of Weighbridge Systems Are Available In Site ) . ( Once In 2 Months For Service & Checking ) 4 Charges For Cleaning Of Mud And Ash Deposits Over The Load Cell And Load Cell Chamber.This Work Includes Removing The Cover Plate Of Load Cell Chamber, Remove The Mud, Ash Deposits And Fix The Cover Plate. Cleaning Of Mud And Ash In Between The Platform And Ramp And Ensure Free Movement Of Weighbridge Platform. 5 Charges Forpainting With One Coat Of Rust Converter, One Coat Of Epoxy Red Oxide Primer And One Coat Ofepoxy High Build Coal Tar One Over The Other With Proper Intervals Over The Structures, Weighbridge Platform And Supports. 6 Hire Charges For T & Ps And Charges For Consumables For Item Sl. No. 4 & 5 7 Ii ) 25 Nb Ball Valve 1 No. ( Leader Makegun Metal Valve )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
8.
Chemicals and Fertilizers #9821440 AOC
Bids Are Invited For 1 STARTER TYPE- 2SM127,12 VOLTS ,PART NO.26925225A ROTATION CLOCKWISE ,MAKE-LUCAS -TVS FOR 17 T TATA MAKE TRAILOR 2516TC 300130009 2 NO 2 LUCAS TVS MAKE STARTER MOTOR FOR 30T CRANE/LUB TRUCK TYPE-GB55-12V LUC AS PART NO GB55-12P-189C. 300057731 2 NO 3 COMPLETE COACH FAN WITH SWIVEL MOUNTING BRACKET TYPE CF-200, 24V DC MAKE:REMI UDYOG FOR CRANES 300109883 10 NO 4 MINIATURE BULBS 12V, 3W PIN TYPE,SINGLE POINT, CLEAR GLASS FOR AUTOMOBILE 300082598 50 NO 5 MINIATURE BULBS 24V, 6W PIN TYPE,SINGLE POINT, CLEAR GLASS FOR AUTOMOBILE 300082599 50 NO 6 HALOGEN BULB TYPE H4-24V-100/90W MAKE MICO/LUMAX OR EQUIVALENT 300082600 50 NO 7 HOLDER FOR HALOGEN BULB 24V,90W WITH THREE WIRES OF LENGTH 2 FOR AUTOMOTIVE USE 300082601 15 NO 8 HYDRAULIC CRIMPING TOOL SET HAND OPERATED HYDRAULLIC COMPRESSION LIGHT WEIGHT COMPACT DESIGN TOOL WITH A TWO STAGE SETTING OF HIGH AND LOW PRESSURE FOR QUICK OIL OUTPUT. FOR USE WITH INTERCHANGEABLE DIE SET OF 25SQ.MM TO 400SQ.MM. RELIABLE, POSITIVE CRIMPING MECHANISM INCORPORATING CALIBRATED PRESSURE RELIEF VALVE. COMPRESSION FORCE: - 16 METRIC TONS. MAXIMUM STROKE: - 24MM TO 32MM. OPERATING PRESSURE: - 10,000PSI/700KG/CM2. DIES TO BE SUPPLIED ALONGWITH THE CRIMPING TOOL. DIE TO BE MANUFACTURED OF HIGH GRADE ALLOY STEEL. CAPCAITY: 25 SQ MM TO 400 SQ MM. MAKE: XTRA, DOWELLS, JAINSON OR EQUIVALENT OR REPUTED MAKE. WARRANTY/GUARANTEE: 1 YEAR FROM THE DATE OF SUPPLY. 300138146 1 NO 9 PHOTOELECTRONIC SMOKE DETECTOR -SENSOR - FOR ALARM SYSTEM- WHITE COLOR MODEL-MI-PSE-S2-IV. M200S2 DETECTOR SERIES. MAKMORLEY-IAS BY HONEYWELL DIMENTIONS :( QXH) 102MMX43MM, OPERATING VOLT: 15-32VDC, O/P CURRENT: 10.8MA SENSOR TO BE FIT WITH B501AP BASE. APPROVED BY EN54 (LPCB & CPD) MAKE: MAKMORLEY-IAS BY HONEYWELL OR EQUIVALENT. 300139920 4 NO 10 CORDLESS IMPACT WRENCH GDS 14.4V- LI PROFESSIONAL .BATTERY 2.6AH, NO LOAD SPEED- 0-2800RPM, TORQUE- 160NM, BATTERY VOLTAGE: 14.4V, TOOLHOLDER: 1/2 EXTERNAL SQUARE. SCREW DIAMETER: M6-M16. WITH BATTERY CHARGER AL 1860CV, 2X 2.6AH BATTERIES, BELT CLIP, HAND STRAP & CARRYING CASE. PART NO.0 601 9A1 TFO OF BOSCH 300105354 1 NO 11 LED TUBE ROD 4 FOOT,T8, 230 V AC, 50 HZ,20w+/-2, BASE CAP G13 BI PIN, MINIMUM 1600 LUMENS, COOL WHITE TEMPERATURE RANGE: 5500 6500K, CRI- MIN 70, LM80 CERTIFIED, MAKE: CROMPTON/BAJAJ/ EQUIVALENT MAKE 300115070 100 NO 12 5 AMP/ 15AMP SWITCH SOCKET COMBINED 6-PIN TERMINALS, 250VOLTS MAKE: ANCHOR OR EQUIVALENT, AS PER LATEST BIS STANDARD 300055324 5 NO 2 13 STRAIGHT SHANK TWIST DRILL HSS JOBBER SIZE: 3 MM.ADDISON/IT. 350000847 50 NO 14 STRAIGHT SHANK TWIST DRILL OF HSS JOBBER, SERIES SIZE: 4 MM.DIA. MAKE: A DDISON/IT. 350000850 50 NO 15 STRAIGHT SHANK TWIST DRILL OF HSS SIZE: 5 MM.DIA. MAKE: JOBBER, ADDISON, I.T. 350000853 10 NO 16 LED FLOOD LIGHT FITTING, 50W ± 5W, 230V AC, COOL WHITE, IP65, 4KV SURGE PROTECTED, LUMEN: MIN 100 LUMEN/WATT, TEMPERATURE RANGE: 5500-6500K, CRIMIN 70 SQUARE SHAPE, BIS APPROVED, MAKE:SYSKA/ BAJAJ/EQUIVALENT MAKE 300129404 50 NO 17 DC182B Reversing Contactor, 48DC volt, 150A, Double Pole, Changeover Contacts Changeover Contacts, Albright Curtis Dc 182B-7, 48Volt or DC182B537T make: Albright/Curtis or equivalent 300156679 4 NO 18 Emergency Disconnect switch,48VDC, 125A heavy-duty compact emergency battery disconnect switch, Red/Black, range-12v-48DC volt+ min 125A, SinglePole, Single-Throw (SPST), Model: Albright/Curtis ED-125-34, 48Volt, Make: Albright/Curtis or equivalent 300156680 30 NO 19 Jumbo Traction controller,48V 450A, 632T44221, Rating 48VDC, 450A, SEVCON Powerpak Traction controller 48V 450A 632T44221 used in 48 DCvolt 4 wheel jumbo electrical system Make: EVS or SEVCON, Part no. 632T44221 300156681 2 NO 20 2000W Step Down Voltage Converter, 230VAC/110VAC, 50Hz/60Hz Digital Display & Thermal Reset Switch and Heavy-Duty transformer Make & model : Axvolt 2000W Elite or equivalent 300156682 1 NO 21 Battery Terminal Coat (250 ml), Rust and Corrosion Protect- Battery Terminals Enhances Battery Life Make & model: 3M Battery Terminal Coat (250 ml) 300156683 15 NO 22 RETROFIT KIT FOR 4WHEEL JUMBO, Kit shall consist of prewired all acceesories for operation of 4wheel jumbo supplied by 36volt battery along with frame Mosfet Controller, Main contactors, Directional contcators, Foot pedal control, base plate & supporting frame to mount all accessories. Complete wiring kit along with motor cable assembly for installation 300156684 2 NO 23 Weatherproof PLEXO3 IP65 cabinets 8 Module 415volt, Impact-resistant reinforced polystyrene material Cabinets with earth + neutral terminal block supplied, with Din rail , transparant door, Lockable door handle, tamper-evident cover and faceplate Legrand Cat- 601978 or equivalent 300156685 15 NO 24 Weatherproof PLEXO3 IP65 cabinets 4 Module 415volt, Impact-resistant reinforced polystyrene material Cabinets with earth + neutral terminal block supplied, with Din rail, transparant door, Lockable door handle, tamper-evident cover and faceplate Legrand Cat-601974 or equivalent 300156686 10 NO 25 Weatherproof PLEXO3 IP65 cabinets 12 Module 415volt, Impact-resistant reinforced polystyrene material Cabinets with earth + neutral terminal block supplied, with Din rail , transparant door, Lockable door handle, tamper-evident cover and faceplate Legrand Cat-601981 or equivalent 300156687 15 NO 26 Themisto TH-B830 Breadboard 830 Points Themisto 830-pin breadboard in white color provides an extensive prototyping area with 830 interconnected holes, allowing you to build complex circuits for all types of components, Fit for jumper wire of 0.8mm diameter standard 2.54mm hole spacing, Color legend on distribution strips Themisto TH-B830 or equivalent 300156688 20 NO 3 27 Pre-wired 0.75 Kw Forward Reverse Motor Starter with enclosure, 3Ph Voltage: 415 V AC IP54, forward- reverse- stop push button of Green, Red, Black color, Starter should provide complete protection of overloading , R-F ineterlock, LK, Schneider, siemens, or equivalent 300156634 1 NO 28 TOGGLE SWITCH, DPDT WITH CENTRE OFF, 230AC, 24V DC, 20A, MOULDED BODY, SCREW TERMINALS, 300085865 30 NO 29 BAR PRIMARY TYPE EPOXY CAST RESIN LV CURRENT TRANSFORMER.RATIO-1000/1A CLASS-5P10, BURDEN-15VA, CONT.CURRENT-1.2xIN, ALF-10, Ith=60IN, Idyn= 2.5Ith INSULATION CLASS-MIN.E. STANDARD- IEC 60044-1 & IS 2705-1 CT TERMINALS SHALL BE ENGRAVED AND TERMINAL COVER TO BE PROVIDED. RTC SHALL BE SUBMITTED ALONG WITH THE CT. MAKE RISHABH/AE/MECO/PRAGATI/KAPPA 300138546 5 NO 30 BAR PRIMARY TYPE EPOXY CAST RESIN LV CURRENT TRANSFORMER.RATIO-1250/1A CLASS-5P10, BURDEN-10 VA, CONT.CURRENT-1.2xIN, ALF-10, Ith=60IN, Idyn=2.5Ith INSULATION CLASS-MIN.E. STANDARD- IEC 60044-1 & IS 2705-1 CT TERMINALS SHALL BE ENGRAVED AND TERMINAL COVER TO BE PROVIDED. RTC SHALL BE SUBMITTED ALONG WITH THE CT. MAKE- RISHABH/AE/MECO/PRAGATI/KAPPA 300146973 5 NO 31 BAR PRIMARY TYPE EPOXY CAST RESIN LV CURRENT TRANSFORMER.RATIO-1600/1A CLASS-5P10, BURDEN-10 VA, CONT.CURRENT-1.2xIN, ALF-10, Ith=60IN, Idyn=2.5Ith INSULATION CLASS-MIN.E. STANDARD- IEC 60044-1 & IS 2705-1 CT TERMINALS SHALL BE ENGRAVED AND TERMINAL COVER TO BE PROVIDED. RTC SHALL BE SUBMITTED ALONG WITH THE CT. MAKERISHABH/AE/MECO/PRAGATI/KAPPA 300146969 10 NO 32 DIGITAL MULTIFUNCTION METER FOR 3PH-3W/4W, LT SYSTEM. INPUT: 415[L-L] VOLT, 50HZ, 1A. PROGRAMMABLE CT PRIMARY, NO PT. TRMS MEASUREMENT, ELECTRICAL PARAMETERS: 3PH V [L-L, L-N], I, IN, HZ, KW, KVA, KVAR AND ENERGY. ACCURACY: 0.5%, SIZE: 96X96 MM PANEL MOUNTING, 3 LINE 4 DIGIT LED DISPLAY, AUX. SUPPLY: 80-240AC/DC UNIVERSAL. RISHABH MODEL 3430. 300094380 15 NO 33 FUSE 200A, 690V(IEC), 200 kAIC, HIGH SPEED, SQUARE BODY, TOP FUSE STATUS INDICATOR, FUSE, BLADE END X BLADE END, CLASS aR, DIN 43 620, AS PER ATTACHED SPECIFICATION SHEET, MAKE EATON CATLOGUE NO 170M1370 OR EQUIVALENT 300154564 10 NO 34 FUSE LINK, HIGH SPEED SQUARE BODY FUSE, 16A, AC690V, 200KA, DIN 000, gR, DIN, IEC 60269, DUAL INDICATOR, LIVE GRIPPING LUGS MAKE BUSSMANN OR EQUI, PART NO 170M1559D OR EQUI. 300150144 30 NO 35 FUSE LINK, HIGH SPEED SQUARE BODY FUSE, 25A, AC690V, 200KA, DIN 000, gR, DIN, IEC 60269, DUAL INDICATOR, LIVE GRIPPING LUGS MAKE BUSSMANN OR EQUI, PART NO 170M1561D OR EQUI. 300150143 30 NO 36 FUSE HRC TYPE HF 63 A CAT.NO.SF 90159 L&T MAKE. 300056422 30 NO 37 FUSE HRC, DIN TYPE, RATING:63AMP, 500V AC, SIZE 000, MAKE: SIEMENS, TYPE 3NA7 822-0RC 300056377 30 NO 38 MOTOR PROTECTION RELAY MPR302, 4-11A, AUXILARY SUPPLY 240VAC, WITH THERMAL OVERLOAD, EARTH FAULT, SINGLE PHASING, LOCKED ROTOR AND UNDERCURRENT PROTECTION, CAT. NO. MPR302BE040, MAKE- L&T OR EQUIVALENT 300140111 5 NO 4 39 MOTOR PROTECTION RELAY MPR303, 8-22A, AUXILARY SUPPLY 240VAC, WITH THERMAL OVERLOAD, EARTH FAULT, SINGLE PHASING, LOCKED ROTOR AND UNDER CURRENT PROTECTION, CAT. NO. MPR303BE080, MAKE- L & T OR EQUIVALENT 300140137 5 NO 40 MOTOR PROTECTION RELAY MPR304, 16-44A, AUXILARY SUPPLY 240VAC, WITH THERMAL OVERLOAD, EARTH FAULT, SINGLE PHASING, LOCKED ROTOR AND UNDER CURRENT PROTECTION, CAT. NO. MPR304BE160, MAKE- L & T OR EQUIVALENT 300140138 5 NO 41 MOTOR PROTECTION RELAY MPR304, 32-88A, AUXILARY SUPPLY 240VAC, WITH THERMAL OVERLOAD, EARTH FAULT, SINGLE PHASING, LOCKED ROTOR AND UNDER CURRENT PROTECTION, CAT. NO. MPR305BE320, MAKE- L & T OR EQUIVALENT 300140139 5 NO 42 NUMERICAL UNDER VOLTAGE RELAY WITH AUX. AND INPUT SUPPLY 230V AC 2WIRE PROTECTION FOR VOLTAGE : 40% 90%, TIME : 0-10 SEC SETTABLE (AS PER ATTACHED SPECIFICATIONS) 300080276 3 NO 43 NUMERICAL EARTH FAULT RELAY AUX. SUPPLY 230V AC INPUT THROUGH 1A CT DEFINITE AND INVERSE TIME PROTECTION (AS PER ATTACHED SPECIFICATIONS) 300080277 3 NO 44 Disel Pump Battery UPS LP 12-7.0(12V7.2Ah), make: Leoch, Exide Type :Offline/Standby, Form Factor: Tower Model, Battery Type: smf Overload Protection: No, Color: black /white Input Voltage: 12 V, Input Frequency: 50 Output Voltage: 12 V, Output Frequency: 50 Output Power Wattage: 84 W, Efficiency: 100%, Output Waveform: Any Transfer Time: 0 ms, Number of Outlet Plugs: 2 Dimensions: Width: 6.4 cm, Height: 9.4 cm, Depth: 15.1 cm, Weight:3.5kg Battery CapacityP: 7.2, Domestic Warranty: 1 Year 300148030 2 NO 45 HIGH PRESSURE ELECTRIC WASHER FOR VALVE CLEANING AS PER FOLLOWING SPECIFICATION: 1. COLD WATER HIGH PRESSURE TYPE 2. SUPPLY: 220-240 VAC SINGLE PHASE SUPPLY 3. ELECTRIC CABLE LENGTH: 5M 4. WORKING PRESSURE: 110-139 BAR 5. HOSE LENGTH: 5M 6. PUMP RPM: 1450 7. FLOW RATE: 500-599 LPH 8. MOTOR RATING: 1.6 KW 9. DETERGENT TANK:1L 10. STANDARD SPRAY GUN 11. IPX5 RATED WASHER 12. SPRAY LANCE: 1000MM MATERIAL SHOULD BE PROVIDED WITH ACCESSORIES TO CONNECT TO ORDINARY GARDEN HOSE FOR WATER INLET. 300150141 6 NO Total Quantity : 790
Contract Date: Ref. Documents Contract Value : 23.90 Lakh
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
9.
Educational and Research Institute #9808971 AOC
Bids Are Invited For 18650 Lithium Ion Battery - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Pure Nickel Strip 99 Point 6 Percent - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 18650 1X1 Single Battery Cell Spacer Holder - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Battery Spot Welder 5000W - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 18650 3S, 20A, 12 Point 6V Lithium Bms Battery Protection Board - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 3S 40A,12Point6v,18650 Li Ion Lithium Battery Protection - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 7S 24V, 20A Bms 18650 Lithium Battery Protection Board - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 6S 12A, 24V, Pcb Bms Protection Board - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ar Cross Filament Strapping Tape - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 2 Point 5 Sq Mm Flame Retardant Electric Wire - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1 Point 5 Sq Mm Flame Retardant Electric Wire - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Multi Function Crimping Stripper Tool - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Pvc Heat Shrink Sleeve For Lithium Battery - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Battery Voltage Internatal Resistance Meter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Pvc Insulation Tape, Blue - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Silicone Oil Lubricant Spray 550Ml For Treadmill - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Multipurpose Spray, Lubricant, Rust Remover - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Banana Audio Connector - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Taparia Multi Purpose Combination Pliers - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Stanley 84 214 22 130Mm 5Point25 Inch Wire Stripper - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Long Nose Plier 6Inch, Versatile Hand Tools - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Towerpro Mg995 Plastic Gear Servo Motor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Towerpro Sg90 Mini Servo - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Esun Pla Plus 1Point75mm 3D Printing Filament 1Kg White - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Esun Pla Plus 1Point75mm 3D Printing Filament 1Kg Silver - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Esun Pla Plus 1Point 75Mm 3D Printing Filament 1Kg Black - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Esun Pla Plus 1Point75mm 3D Printing Filament 1Kg Grey - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 3D Printer Extruder Nozzle Of 22 Pieces - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 3D Print Tool Kit Set - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 3D Printer Filament Storage Bags With Manual Air Pump - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Soldering Station With Hot Air Gun Handle , Soldering Iron - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 6 Flexible Arms Soldering Station With Swiveling Alligator Clip - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Xy128vc 5Point0 Xinya 3 Pin Screw Terminal Block - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 2 Pin 5 Point 08Mm Pitch Pluggable Screw Terminal Block - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 201 Series 4 Pin Male Female Connector With Crimping Pins - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1X40 Pin 2Point54mm Berg Strip Male Connector - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1000 Kv Bldc Brushless Dc Motor For Drone - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Carbon Fiber Quadcopter Drone Frame Kit - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Pro Range Propellers 1Cw Plus 1Ccw 1Pair - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Apm 2 Point 8 Flight Controller With Built In Compass - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1200Tvl Cmos Camera With 2 Point 1Mm Lens Fpv Camera - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ewrf 5Point8g Uvc Otg Android Av Phone Receiver - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ts5828l 5Point 8G 600Mw 40Ch Transmitter With Antenna - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Df13 6 Pin Flight Controller Cable - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , F4 V3s Plus Flight Control Osd 2 6S - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Power Module Pm02 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Neo 6M Gps Module With Eprom - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Neo M8n Gps With Compass For Pixhawk - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Simonk 30A Bldc Esc Electronic - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Stanley 2000W Variable Temperature Heat Gun - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 200W 20A Dc Dc Buck Converter Step Down Module - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 200W Dc Dc Boost Converter 6 35V To 6 55V Step Up - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Wz3605e 80W 5A Adjustable Buck Boost - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Scr Speed Controller Dimmers Voltage Regulator - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Scr Characteristics Trainer - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Egs002 Eg8010, Ir2113 Dc Ac Spwm - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Festnight Compact Variable Voltage Controller - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Kbpc5010 50A 1000V Diode Bridge Rectifier - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Fnirsi P6100 Oscilloscope Probe - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ammeter 0 250 Micro Amp - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Triac Characteristics Apparatus With Regulated - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Fluke 101 Digital Multimeter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Rechargeable Aa Battery With Charger - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Battery Charger With 2 X Aa And 2 Aaa Batteries - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Universal Battery Charger - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 5X20mm 250V 5A Glass Tube Fuse - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 5X20mm 250V 2A Glass Tube Fuse - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 5X20mm 250V 10A Glass Tube Fuse - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Rechargeable Batteries Aa 1300Mah - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Rechargeable Aaa 900Mah Batteries - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Teflon Tubing Tube, 6Mm Id X 8Mm Od Teflon Tube - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Teflon Tubing Tube, 4Mm Id X 6Mm Od Teflon Tube - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Carbon Conductive Tape - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Temperature Sensors High Accurate - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Gas Sensors Nox, Voc - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Humidity Sensors With High Accurate For Industrial Purpose - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Electrical Safety Gloves, 33Kv - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 24Awg Single Core Teflon Wire 1 Meter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Opamp Tl082cp Integrated Circuits - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Standard 4Mm Banana Plug To 45Mm - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Edm 80 Desk Stand Analog 0 To 500Mv Dc Moving Coil Milli Voltmeter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Edm-80 Desk Stand Analog 0 To 10Ma Dc Milli Ammeter Moving Coil - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Xt60 Connector Male Housing 10Cm Silicon Wire 14Awg - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Xt60 Plug Female Connector With 14Awg Silicon Wire - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Xt60 Male And Female Plug Bullet Welding Terminal - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Analog 0 To 500 Ua Micro Ammeter Moving Coil Ampere Meter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Resistance Decade Box Rdb6 1 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Capacitance Decade Box 1 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 5 Dials Decade Inductance Box Ml 3005 Ml 3005 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Multi Meter Test Probes Cable Set Test Model - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1By2w Zener Diode Bzx55c16v Zener Voltage - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1N4007 1W Diodevoltage - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Bc547 Npn Dip Transistor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Bc557 Pnp Transistor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 2N2222 Npn Transistor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Bc107 Npn Transistor Bc107 Transistor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Capacitor Kit 1000 Microfaradmaterial - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Irf540n To 220 3 Mosfet - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 3 In 1 Aluminum Heat Sink Set For Raspberry Pi 3By4 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Stackable Banana To Banana Plug Test Leads - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 10K Ohm 3Pin 13Mm Shaft Potentiometer - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 7400 74Hc00, 74Hc00n Quad 2 Input Nand Gate - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Triple 3 Input Nand Gates With Open Collector Output - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Cd4001be Nor Gate, Cd4001, 4001 Ic - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 74Hc27d Triple 3 Input Nor Gate Ic Soic - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 74Hc86 Quad 2 Input Exor Gate Ic Dip - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Sn74hc04n 7404 Ic Inverter,74Hc04 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Sn74hc08n 7408 Ic And Gate Logic Gate - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 74Hc86 Quad 2 - Input Exor Gate Ic Dip - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ic Or Gate Logic Gate, 74Ls32, - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ne555 555 Timer Ic Astable Monostable Timer 555 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ga12 N20 12V 1000Rpm Dc Gear Motor With Encoder - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Gb37y3530 12V 83R Metal Dc Geared Motor Encoder - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Encoder Motor Set, Micro Dc12v High Torsion Dc Geared Motor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ir Break Beam Sensor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Xl4015 5A Step Down Adjustable Power Supply With Led Voltmeter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Oscilloscope Test Probe Bnc To Crocodile Probe - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Raspberry Pi 5 Model 1Gb Rammodel Raspberry Pi 5 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Raspberry Pi Zero W Wireless - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Official Arduino Due Board A000062 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Stm32f4discovery St Stm32 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Arduino Nano Usb A Mini B 1Point2m Cable - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 1N5822 1W Schottky Diode Maximum - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Crystal Oscillator 1Mhz Scientech 1Mhz - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 35Cm Usb 2Point0 A To Mini 5 Pin B Cable - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Hdmi 30Meter 98Point42ft Hdmi Cable - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 5 Inch Touch Screen Hdmi Interface Tft Lcd - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 600Mm Trapezoidal 4 Start Lead - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 12Mm 5Mw Red Point Laser Module Cht1230 P - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 12V Warm White 5050 Smd Led Strip 1Meter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Esp32 Wrover B Board For Arduino - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Pbs 422Ad Plastic Push Button Latching Switch 22Mm - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Tactile Push Button Switch 6X6x5 - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ad8232 Ecg Heart Rate Monitoring Sensor Module Kit - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ds18b20 Water Proof Temperature Probe - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , As608 Optical Fingerprint Sensor Fingerprint Module - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Flame Sensor Module - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Groove Coupler Speed Measuring Sensor Module - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Pro Range 12V 600 Rpm Johnson Geared Dc Motor - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , 2Point0 Channel Digital Stereo Audio Power Amplifier Board - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Mp3 Bluetooth 4Point1 Decoder Board - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Bosch Gis 500 Temperature Meter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Standard 5V, 2A Power Supply Adapter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Arduino R3 Original - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Oscilloscope Probe Clip, 100Mhz - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Fluke 101 Digital Multimeter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Ac Dc Converter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Oscilloscope Probe, Passive, 200 Mhz, 600 V, Oscilloscopes - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Tms320f28379d Launch Xl - Specifications And Accessories Shall Meet The Bid Specification Document Criteria , Digital Ac Dc Clamp Meter - Specifications And Accessories Shall Meet The Bid Specification Document Criteria Total Quantity : 7072
Contract Date: Ref. Documents Contract Value : 15.11 Lakh
Boards / Undertakings / PSU No of Bidders 3
Andhra Pradesh View Result →
10.
Health and Family Welfare #9736762 AOC
Tender For Supply Of Dental Items , Ortho Impalants And Other Items , Medicins And Lab Items , Inj. Loxcard 50 Ml 2% , Inj. Clonidine 30 Mg , Inj. Clonidine 150 Mg , Inj. Dexmedetomidine 100 Mcg , Prolene 3 - 0 , Abdominal Drainge Kit , Inj. Butorphanol Tartirate 1Mg/Ml , Noramal Saline 3 Ltr , Inj. Betaloc 5 Mg , Inj. Cardarone 3 Ml , Brain Circuit , Irregatton & Aspiration Cannula No. 23 G , Hydro Direction Cannula , Laryngcal Mask Airway Size No. 3 , Curved Conjuctive Scissor , Nasopharngeal Air Way No. 6 , Nasopharngeal Air Way No. 7 , Nitrous Oxide Inhalation , Chlorpheniramine Tablet 4 Mg , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Levamasole Tablet 50 Mg , Levamasole Tablet 150 Mg , Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent , Cloxacillin Capsule 500 Mg , Methyldopa Tablet 250 Mg , Methyldopa Tablet 500 Mg , Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle , Betamethasone Dipropionate Cream 0.1% W/W , 5 Gm , White Petrolatum Jelly 100 %, 50 Gm Jar , Pyridium Tablet 200 Mg , Pilocarpine (Hydrochloride Or Nitrate) Eye Drops 2 %, 5 Ml Squeeze Vial , Ichthoimol Glycerine Solution 10 Ml Vial , Mometasone + Terbinafine Ointment 15 Gm , Methyl Ergometrine Tablet 125 Mcg , Olanzapine Tablet 20 Mg , Perampenel 2 Mg , Atomoxitine Capsule 10 Mg , Formoterol (6Mcg) + Budesonide (200Mcg) (Foracort Inhaler) , Chloroquine Phosphate Tablet 250 Mg, Equivalent To 155 Mg Chloroquine Base , Primaquine Tablet 15 Mg , Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg , Weekly Iron Folic Acid Tablet Each Tablet Containing 60 Mg Elemental Iron+500 Mcg Folic Acid, Sugar Coated ,Blue Colour , Iron And Folic Acid Tablet ( Wifs Junior ) Containing Dried Ferrous Sulphate Ip Equivalent To Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet. Tablet Are Sugar Coated And Pink Coloured Tablets With Only Edible Colours Used Tablet Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet , Waterproof Bed Sheet , Adult Diapers , Eatraction Forcep Set , Elevator Set , Peristel Elevator , Kidney Tray , Plastic Filling Instrument , Ball Burnisher , Steel Cemant Spatula , Artery Forceps , Hand Sealer Set , Glass Slab , Weighing Scale Digital Adult One Year Warranty , Weighing Scale Digital Paediatric One Year Warranty , Stadiometer , Measuring Tape , Thermometer Digital , Digital Bp Appratus Automatic One Year Warranty , Cotton Swabs , Sims Speculum - Metal , Cuscos Speculum (Large / Medium / Small) Metal , Spot Examination Lamp , Ayres Wooden Spatula , Endocervical Cytobrush , Combi - Brush , Coplin Jar Glass , Coplin Jar Plastic , Stethoscope Good Quality Isi Certified , Cyclophosphamide Tablet 50 Mg , Etoposide Capsule 50 Mg , Lenalidomide Tablet 10 Mg , Tamoxifen Citrate Tablet 20 Mg , Dexamethasone Tablet 4 Mg , Dexamethasone Tablet 8 Mg , Temozolamide Tablet 250 Mg , T- Connector , Y- Connector For 8-10 Mm , Uro Bag (Neonates)- 100 Ml , Surfactant- Survanta(Synthetic)(25 Mg/1Ml), Exosurf (Bovine) , Chest Drain (Adults) , Td Vaccine , Nicotine Pastilles 2 Mg , Nicotine Pastilles 4 Mg , Tablet Buspirone 5 Mg , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 15Cm X 15 Cm Square (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging , Potassium Peroxomonosulphate 50% W/W Containig Aldehyde Free Disinfectant , 5 Kg , Anterior Chamber Kellmann Multi Flex 4 Point Fixation Type Optical Diameter 6Mm,Overall Length 12.5 Mm, Dioptric Range 10D To 30 D , I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye) , Guide Wire Teflon Coated J Tip , Guide Wire Teflon Coated V Straight Tip , Naocl 5.25% Solution Isi/ Iso/Ce/Marked. , Topical Fluoride Apf Gel 1.25% , T Plus Eye Drops , Paracine Eye Drop , Gatiquin - P Eye Drop , Tropicamide Eye Drop , Gatiquin - P Eye Drop , Novacide Solution , Two Slot Easy & Convenient Operation For Destroying Needles & Syringes, Where Needle Burns Electrically And Syringe Is Cut Manually Using Sharp Steel Blade Within Seconds. Economical, Sturdy, Simple To Operate Healthcare & Surgical Machine Consuming Low Power. Powder Coated Strong Metal (Copper) Body With Shock-Proof Main Circuit Breaker And Provision Of On/Off Switch With Pilot Lamp. , Inj. Vitamin D3 / Cholecalciferol(600000.0 Iu/Ml) , 1 Annual Periodical Maintenance Of Vitamin C 150 Mg/1.5 Ml, 2 Amps Of Vitamin B12 2500 Mcg, Folic Acid 0.7 Mg, Niacinamide 12 Mg/1 Ml (Eldervit Inj.) , Silver Alloy Non-Gamma-2 Lathe Cut Alloy (Dpi/Dentsply/Prevest) , Eugenol (Dpi/Dentsply/Prevest) , Zinc Oxide Powder (Dpi/Dentsply/Prevest) , Pit & Fissure Sealant ( 6 Ml Bottle) Solution , Cavity Varnish 5% Sodium Fluoride (Dentsply / 3 M / Dpi) , Zinc Phosphate Cement , Powder And Liquid (Harvard / Prevest / Dpi) , Formocresol Formalin, Cresol Glycerin ,Formocresol Formalin Bp 20% V/V , Cresol Ip 32% V/V , Glycerin Ip Qs (Prevest / Shofu/ Dpi) , Air Rotor Spray Bottle (Nsk/ Kavo / Confident) , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) (Prevest/ Blossom) , Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution (3 M / Ivoclar/ Shofu) , Electronic Dental Chair With Adequate Accessories (Handpieces, Compressor,Three Way Syringe , Instruments For Manual Cleaning Of Teeth (Api / Samit / Gdc) , Ultrasonic Scaler (Woodpacker / Satelac/ Ems) , Polishing Kit (Shofu/ Dentsply/ Coltene) , Dental X-Ray Unit (Tecnomac / Trophy / Gomax) , Light Cure Gun (Woodpacker / 3 M / Unicorn) , Extraction Forceps (Adult) (Gdc/ Api/ Samit) , Extraction Forceps (Pedo) (Gdc / Api/ Samit) , Restorative (Filling) Instruments (Gdc / Api/ Samit) , Three Way Syringe , Spoon Excavator (Gdc / Api/ Samit) , Fluoride Standard 100 Ppm (Orion) 475 Ml , Hybrid Composite Resin For Anteriors (Shofu/Coltene/3M) , Mineral Trioxide Aggregate (Angulus/Dentsupply/3M) , Petroleum Jelly , Dycal (Septodent/Dentsupply/3M) , Suction Tips Disposable , Orafill-G (Prevest) , Glass Slab , Kidney Trey , Chetal Forcep , Pmt Set (Gdc / Api/ Samit) , Cement Spatula (Gdc / Api/ Samit) , Bone File (Gdc / Api/ Samit) , Surgical Scissor (Gdc / Api/ Samit) , Pain Off Liquid , Glass Bead Sterlizer , Elevator Straight (Gdc / Api/ Samit) , Glass Ionomer Cement- Type-Ix (Gc Fuji/Shofu/3M). , Cryer Elevator (Gdc / Api/ Samit) , Hockey Stick Elevator (Gdc / Api/ Samit) , Luxator Set (Gdc / Api/ Samit) , Uv Chamber , Gutta Percha 17 4% (Dentsply / Diadent/ Meta) , Gutta Percha 20 4% (Dentsply / Diadent/ Meta) , Gutta Percha 25 4% (Dentsply / Diadent/ Meta) , Gutta Percha 20 6% (Dentsply / Diadent/ Meta) , Endorotary Files Orifice Opener (Dentsply / Diadent/ Meta) , Endorotary Files Glide File (Dentsply / Diadent/ Meta) , Endorotary Files 20 4% 21Mm (Dentsply / Diadent/ Meta) , Endorotary Files 20 4% 25Mm (Dentsply / Diadent/ Meta) , Endorotary Files 25 4% 21Mm (Dentsply / Diadent/ Meta) , Endorotary Files 25 4% 25Mm (Dentsply / Diadent/ Meta) , Endorotary Files 20 6% 25Mm (Dentsply / Diadent/ Meta) , 7Th Generation Bonding Agent (3 M / Coltene/ Shofu) , Sodium Hypchloride 5 Ltr 10 % Packing , Diamond Burs Tr 13,Br 41, Straight ( Mani) , K-Files Assorted 21Mm 15No. (Mani/Dentsupply) , K-Files Assorted 21Mm 20No. (Mani/Dentsupply) , K-Files Assorted 21Mm 25No. (Mani/Dentsupply) , K-Files Assorted 21Mm 30 No. (Mani/Dentsupply) , K-Files Assorted 21Mm 15-40 No.. (Mani/Dentsupply) , K-Files 25 Mm 15-40 No. (Mani/Dentsupply) , K-Files Assorted 21 Mm 10No. (Mani/Dentsupply) , K-Files 21Mm 8 No. (Mani/Dentsuply) , Guttapercha Point No. 15-40 /45 -80 (Dentsply / Diadent / Meta) Hey Are Radiopaque, Biocompatible, And Come In Standardized Lengths To Fit Various Canal Depths. , Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer , Trey For Instruments , Dental Rvg (Vatec / Carestream/ Satelac) , Endomotor With Apex Locator (Nsk / W & H / Dentsply) , Arch Bar ( Orthomax/Samit/Dentsuply) , Ss Wire Gauge 26 (Orthomax/Samit/Dentsuply) , Ss Wire Gauge 28 (Orthomax/Samit/Dentsuply) , Rotary Gp 30 # 4 % , Rotary Gp 25- 40 # 4 % , Guttapercha Point No. 15-40 /45 -80 (Dentsply / Diadent / Meta) Hey Are Radiopaque, Biocompatible, And Come In Standardized Lengths To Fit Various Canal Depths. , Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer , Trey For Instruments , Dental Rvg (Vatec / Carestream/ Satelac) , Endomotor With Apex Locator (Nsk / W & H / Dentsply) , Physiodispenser (Nsk, W&H/ Merarhon/Woodpacker) , Dental Implant Kit (Ossteum /Denteum/ Noris/Addin) , Dental Implant Different Sizes(Osstem/Nobel Biocare/ Addin) , Abutment (Straight/Angulated) (Osstem/Nobel Biocare/ Addin) , Gingival Former (Osstem/Nobel Biocare/ Addin) , Dental Bone Caliper (Osstem/Nobel Biocare/ Addin) , Distal End Cutter (Long Handle (Eltee/Jj Ortho/North American)) , Flush End Distal End Cutter (Eltee/Jj Ortho/North American)) , Wingart Pliar (Eltee/Jj Ortho/North American) , Methews Pliar (Eltee/Jj Ortho/North American) , Wire Tucker (Eltee/Jj Ortho/North American) , Plc (Soft Ligature Wire Cutter , Hard Wire Cutter (Gdc/Jj Ortho) , Torqueing Pliar ( Male) (Jj Ortho/ Modern Ortho) , Torqueing Pliar (Female) (Jj Ortho/ Modern Ortho) , Buccal Tube Holder (Jj Ortho/ Modern Ortho) , Bracket Holder (Modern Ortho/North American) , Bracket Gauze Set (Jj Ortho/ Modern Ortho) , D-Bonding Pliar (Cat/Jj Ortho) , Delarosa Pliar (Jj Ortho/ Modern Ortho) , V- Band Forming Pliar (Gdc/Jj Ortho) , Moons Cutter (Gdc/Jj Ortho) , Three Jaw Wire Bending Pliar (Gdc/Jj Ortho) , Tweed Pliar (Eltee/Jj Ortho/North American) , Crimpable Hook Pliar (Eltee/Jj Ortho/North American) , Curved Hoe Pliar (Eltee/Jj Ortho/North American) , Band Removing Pliar (Eltee/Jj Ortho/North American) , Adams Pliar (Eltee/Jj Ortho/North American) , Wire Syncher (Eltee/Jj Ortho/North American) , Lite Composite (Ortho Organiser) , Ortho Solo Primer (Ortho Solo/ Ortho Organiser) , Metal Brackets (O22, Mbt) (Ortho Organiser) , Buccal Tube (Ortho Organiser) , Molar Band With Buccal Tube (Ortho Organiser) , Band Pusher (Ortho Organiser) , Etchent , Cheek Retracter (Ortho Organiser) , Modules (Ortho Organiser) , E Chain Closed (Ortho Organiser) , Ligature Wire ( Oo9, 010) (Ortho Organiser) , Orthodontic Wire (Niti) (Ortho Organiser) , Orthodontic Wire (Ss) (Ortho Organiser) , Tma Wire Straight (Ortho Organiser) , Mini Implants (Sk Surgical/ Favanchor) , Mini Implant Screw Driver (Sk Surgical/ Favanchor) , Rail System All Sizes (Ao / Sorat / Image) , Compression Distraction Unit (All Sizes) (Ao / Sorat / Image) , End Clamp (Ao / Sorat / Image) , Central Clamp (Ao / Sorat / Image) , Swivel Clamp (Ao / Sorat / Image) , Allen Key (Ao / Sorat / Image) , 6.5 Mm Taper Cut Schanz Pins (All Size) (Ao / Sorat / Image) , Ilizarov Half Rings (All Sizes) (Ao / Sorat / Image ) , Ilizarov Wires (Trocar Tip & Bayonet Tip) 1.8 Mm (Ao / Sorat / Image) , Oilve Wires (Ao / Sorat / Image) , Male And Female Post (All Sizes) (Ao / Sorat / Image) , Washers (All Sizes) (Ao / Sorat / Image) , Rancho (All Sizes) (Ao / Sorat / Image) , Conical Washers (Ao / Sorat / Image) , Ilizarov Plates (All Sizes) (Ao / Sorat / Image ) , Hinges (Ao / Sorat / Image) , Bolts (All Sizes) (Ao / Sorat / Image) , Nut (All Sizes) (Ao / Sorat / Image) , Wire Fixation Bolts (Side) (Ao / Sorat / Image) , Wire Fixation Bolts (Centre) (Ao / Sorat / Image) , Angled L Spanners (Bolt Head And Nut Shape) (Ao / Sorat / Image) , Precontoured Distal Fibular Plates (All Sizes) (Ao / Sorat / Image) , One Third Tubular Plate (All Sizes) (Ao / Sorat / Image) , Semi Tubular Plate (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Dcp (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Lc Dcp (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Lcp (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Recon Plate (Locking & Non Locking) All Sizes (Ao / Sorat / Image) , 3.5 Mm Cortical Screw (All Sizes) (Ao / Sorat / Image) , 4.0 Mm Cancellous Screw (Solid) With Washer , Partially Threaded (16 Mm, 32 Mm All Sizes) (Ao / Sorat / Image) , 4.0 Mm Cancellous Screw (Cannulated) With Washer , Partially Threaded (16 Mm, 32 Mm All Sizes) (Ao / Sorat / Image) , 3.5 Mm Cortical Locking Head Screw (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Broad Lcdcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Narrow Lcdcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Broad Lcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Narrow Lcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Cortical Screw (All Sizes) (Ao / Sorat / Image) , 6.5 Mm Cancellous Screw Solid With Washer (Fully & Partially Threaded , 16 Mm , 32 Mm , All Sizes) (Ao / Sorat / Image) , 6.5 Mm Cancellous Screw Cannulated With Washer (Partially Threaded , 16 Mm , 32 Mm , All Sizes) (Ao / Sorat / Image) , 5.0 Mm Cortical Locking Head Screw (All Sizes) (Ao / Sorat / Image) , Proximal Femoral Locking Plate (All Sizes) (Ao / Sorat / Image) , Dhs Plate (Standard Barrel) (Ao / Sorat / Image) , Dhs Plate (Short Barrel) (Ao / Sorat / Image) , Richard Screw (All Sizes) (Ao / Sorat / Image) , Dcs Plate (All Sizes) (Ao / Sorat / Image) , 95 Degree Angle Blade Plate (Condylar Blade Plate) 95 Degree (With All Sizes Blade Length) (Ao / Sorat / Image) , Osteotomy Blade Plate (120 Degree) ( 65 Mm, 75 Mm, 85 Mm) (Ao / Sorat / Image) , Distal Femoral Lcp (All Types , All Sizes , With Screws) (Ao / Sorat / Image) , Proximal Tibial Locking Hockey Plate (All Sizes , With Screws) (Ao / Sorat / Image) , Proximal Tibial Raft Plate System (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Reconstruction Plate Locking & Compression For Pelvie Reconstruction (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Proximal Tibial Postero Medical Locking Plate With Screws Of All Types (3.5 Mm) (Ao / Sorat / Image) , Proximal Tibial T Plates (Locking & Non - Locking ) With Screws Of All Types , All Sizes (Ao / Sorat / Image) , Proximal Tibial L Plates (Locking & Non - Locking ) With Screws Of All Types ,Both Sided, All Sizes (Ao / Sorat / Image) , Distal Tibial Malleolar Locking Plate (All Sizes, With Screws) (Ao / Sorat / Image) , Distal Tibial Metaphyseal Locking Plate (All Sizes, Both Sides , With Screws) (Ao / Sorat / Image ) , Distal Tibial Anterolateral Locking Plate (All Sizes, Both Sides , With Screws) (Ao / Sorat / Image) , 3.5 Mm Precontoured Clavicular Plate (All Sizes, With Screws) (Ao / Sorat / Image) , Clavicle Hook Plate (All Sizes, With Screws) (Ao / Sorat / Image) , Proximal Humerus Locking Plate (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Distal Humerus Lateral Column Precontoured Locking Plate (All Sizes , Both Sides , With Screws) (Ao / Sorat / Image) , Distal Humerus Medical Column Precontoured Locking Plate (All Sizes , Both Sides , With Screws) (Ao / Sorat / Image) , Distal Humerus Extra Articular Precontoured Locking Plate With Screws Of All Types (All Sizes , Both Sides , With Screws) (Ao / Sorat / Image) , Precontoured Radial Head Plate With Screws Of All Types (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Proximal Ulnar Precontoured Locking Plate With Screws Of All Types (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Distal Radius Precontoured Locking Plate (With And Without Varialbe Locking Option) All Sizes Both Sides , With Screws) (Ao / Sorat / Image) , Herbert Cannulated Headles Screws (All Sizes) (Ao / Sorat / Image) , Femur Interlocking Nail With Locking Bolt (All Sizes) (Ao / Sorat / Image) , Proximal Femoral Recon Nail (All Sizes) (Ao / Sorat / Image) , Proximal Femoral Nail 0 Helical Blade Screw For Femoral Head (All Sizes) (Ao / Sorat / Image) , Tibial Interlocking Nail (All Sizes) (Ao / Sorat / Image) , Tibial Interlocking Nail Bolt (All Sizes) (Ao / Sorat / Image) , Expert Tibial Interlocking Nail Ss (All Sizes) (Ao / Sorat / Image) , Expert Tibial Interlocking Nail Bolts Ss (All Sizes) (Ao / Sorat / Image) , High Tibial Osteotomy Plate With Screws Of All Types (All Sizes , With Screws) (Ao / Sorat / Image) , Humerus Nail System (All Sizes) (Steel , All Sizes) (Ao / Sorat / Image) , Schanz Pin (Cortical, Cancellous & Tapering) (Steel , All Sizes) (Ao / Sorat / Image) , Universal Clamps (Steel , All Sizes) (Ao / Sorat / Image) , Universal Tubular Rods, (Steel , All Sizes) (Ao / Sorat / Image) , Universal Rod To Rod Clamps (Steel , All Sizes) (Ao / Sorat / Image) , Universal T Clamp (All Sizes) (Steel, All Sizes) (Ao / Sorat / Image) , Nut (External Fixator, Steel, All Sizes) (Ao / Sorat / Image) , Bolts (External Fixator, Steel, All Sizes) (Ao / Sorat / Image) , Ha Coated Schanz Pin (Steel, All Sizes) (Ao / Sorat / Image) , Femoral Components Of All Sizes And Offsets Including Cdh Stem (Cement In Cement Stem) (Stryker / Johnson Johnson / Zimmer / Meril) , Cement Restrictor (Stryker / Johnson Johnson / Zimmer / Meril) , Stem Centralizer (Stryker / Johnson Johnson / Zimmer / Meril) , Acetabular Cup (Highly Cross Linked, All Sizes) (Stryker / Johnson Johnson / Zimmer / Meril) , Bone Cement (40 Gm) (Stryker / Johnson Johnson / Zimmer / Meril) , Femoral Head (All Sizes & Offsets - 288 Mm , 32 Mm, 36 Mm (Stryker / Johnson Johnson / Zimmer / Meril) , Femoral Component (All Offsets, Fits : Metaphyseal Fit, Metaphysion - Diaphyseal Fit And Metallurgy : , Hydroxyapatite Coating , Tracecualr Metal - Tantalum (Stryker / Johnson Johnson / Zimmer / Meril) , Acetabular Component (Various Hole Combinations, Different Sizes & Shapes : Hemispherical , Oblong, Peripheral Fit) (Stryker / Johnson Johnson / Zimmer / Meril) , Screw For Actabular Fixation (Stryker / Johnson Johnson / Zimmer / Meril) , Uncemented Cup (Stryker / Johnson Johnson / Zimmer / Meril) , Acetabular Liner (Highly Cross Linked Polyethylene) (Stryker / Johnson Johnson / Zimmer / Meril) , Femoral Head (All Sizes & Offsets - 28 Mm , 32 Mm, 36 Mm) (Stryker / Johnson Johnson / Zimmer / Meril) , Bone Cement (40 Gm) (Stryker / Johnson Johnson / Zimmer / Meril) , Femoral Components (All Metallurgy) (Stryker / Johnson Johnson / Zimmer / Meril) , Tibial Component (All Types : Posterior Stabilized , Pcl Sparing, Semi - Constrained, Constrained) (Stryker / Johnson Johnson / Zimmer / Meril) , Highly Cross Linked Polyethylene Insert (Stryker / Johnson Johnson / Zimmer / Meril) , Femoral Components (All Metallurgy) With Extension Rod (Stryker / Johnson Johnson / Zimmer / Meril) , Tibial Component (All Types : Posterior Stabilized , Pcl Sparing , Semi - Constrained , Constrained) With Extension Rod (Stryker / Johnson Johnson / Zimmer / Meril) , Metallic Augmentation Blocks(Stryker / Johnson Johnson / Zimmer / Meril) , Tibial Extension Rod (Stryker / Johnson Johnson / Zimmer / Meril) , Articulated Antibiotic Cement Spacer (Femur & Tibia) (Stryker / Johnson Johnson / Zimmer / Meril) , Rotating Hinged Knee System (Stryker / Johnson Johnson / Zimmer / Meril) , Bone Cement (40 Gm) (Stryker / Johnson Johnson / Zimmer / Meril) , Endo Button (Fixed Loop & Variable Loop) (Stryker / Johnson Johnson / Zimmer / Meril) , Interferential Screw (Metal & Bioabsorable) (Stryker / Johnson Johnson / Zimmer / Meril) , Washer (Spiked & Non Spiked) (Stryker / Johnson Johnson / Zimmer / Meril) , Nitional Guide Wire (Stryker / Johnson Johnson / Zimmer / Meril) , Bone Staple (Stryker / Johnson Johnson / Zimmer / Meril) , Pedicle Screw (Titanium Hydroxyapatite Coated , All Sizes 4.5 Mm, 5.5 Mm, 6.5 Mm, 7.5 Mm) (Stryker / Johnson Johnson / Zimmer / Meril) , Pedicle Screw (Titanium Biaxial & Polyxial , All Sizes 4.5 Mm, 5.5 Mm, 6.5 Mm, 7.5 Mm) (Stryker / Johnson Johnson / Zimmer / Meril) , Connecting Rods (Titanium All Sizes 4.5 Mm, 5.5 Mm, 6.5 Mm, 7.5 Mm) (Stryker / Johnson Johnson / Zimmer / Meril) , Cage (Titanium , Peek, Mesh , All Sizes) (Stryker / Johnson Johnson / Zimmer / Meril) , Suture Anchor (Single Loaded For Single & Double Row) (Stryker / Johnson Johnson / Zimmer / Meril) , Suture Anchor (Double Loaded Fibertape) (Stryker / Johnson Johnson / Zimmer / Meril) , Arthroscopic Cannula (Stryker / Johnson Johnson / Zimmer / Meril) , Suture Passer (All Angles, Chia Wire) (Stryker / Johnson Johnson / Zimmer / Meril) , Suture Anchor (Single Loaded For Single & Double Row) (Stryker / Johnson Johnson / Zimmer / Meril) , Suture Anchor (Double Loaded Fibertape) (Stryker / Johnson Johnson / Zimmer / Meril) , Arthroscopic Cannula (Stryker / Johnson Johnson / Zimmer / Meril) , Suture Passer (All Angles , Chia Wire) (Stryker / Johnson Johnson / Zimmer / Meril) , Burr (Stryker / Johnson Johnson / Zimmer / Meril) , Shaver (Stryker / Johnson Johnson / Zimmer / Meril) , All Inside Meniscus Suture (Stryker / Johnson Johnson / Zimmer / Meril) , Ultrabraid / Fiberwire Suture (All Sizes) , Modular Bipolar Femoral Prosthesis (Uncemented) All Sizes , Modular Bipolar Femoral Prosthesis (With Bone Cement) , Antibiotic Bone Cement (40 Gm) , Bone Cement 40 Gm , Pulse Lavage (All Sizes) , Sterile, Single-Use Surgical Drapes For Orthopedic Procedures (E.G., Knee Replacement), Typically Made From Fluid-Repellent, Non-Woven Materials Like Sms Or Ssmms (Approx. (43) Gsm). Key Features Include A Reinforced Area, An Elastic Aperture (Approx. 62 Mm) For The Knee,, And Dimensions Roughly 240X350 Cm To 240X370 Cm, Designed For, Infection Control. Knee O Drape , Cling Drape , Ioban , Stockinet , Universal Knee Brace , Disposable Sterile Sheets , Drain No. 14 , Drain No. 16 , G - Dress Of Various Sizes , Lightweight And Comfortable · Adjustable Neckline · Good Strength Characteristics · High Barrier Performance · Meets En13795 Requirements For Standard Performancesterilized Disposable Surgical Gown , Inj. Bupivaccine 20 Ml , 5-0 Silk Suture For Eye Surgery , 8-0 Vicryl Suture For Eye Surgery , Cartoviejo Calipers For Eye Surgery , Utrata Capsulorlexige Forceps For Eye Surgery , Green Blade , Oxygen (Medicinal Gas) Inhalation , Nitrous Oxide Inhalation , Morphine Injection 10 Mg/Ml, 1 Ml Ampoule , Morphine Tablet 20 Mg , Tramadol Hydrochloride Capsule 100 Mg , Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule , Pethidine Injection 50 Mg/Ml, 1Ml Ampoule , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent , Metronidazole Tablet 200 Mg , Hydroxycobalamin Injection 1 Mg/ Ml , Warfarin (Sodium) Tablet 2 Mg , Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms , Nifedipine Capsule(Sublingual) 5 Mg , Podophylline Resin Topical Solution 25% , 10 Ml Bottle , Furosemide Tablet 20 Mg , Mifepristone Tablet 25 Mg , Misoprostol Tablet 25 Mg , Chlorpromazine (Hydrochloride) Tablet 100 Mg , Fluphenazine Injection 25 Mg, 1 Ml Ampoule , Haloperidol Tablet 5 Mg , Risperidone Injection Long Acting 25 Mg , Olanzapine Injection 405 Mg , Olanzapine Injection 10 Mg , Olanzapine Injection 210 Mg Long Acting , Olanzapine Injection 300 Mg Long Acting , Donepezil Injection 10 Mg , Buprinorphine Tablet 2 Mg , Buprinorphine Tablet 0.4 Mg , Methylphenidate Tablet 5 Mg , Tranylcypromine Tablet 5 Mg , Buprenorphine Transdermal Patch 10 Mcg/Hour , Buprenorphine Transdermal Patch 20 Mcg/Hour , Agomelatine Tablet 25 Mg , Cariprazine Tablet 1.5 Mg , Pyridoxine Tablet 10 Mg , Chloroquine Phosphate Injection 40 Mg/Ml , Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50 Ml Bottle , Quinine Sulphate Tablet 300 Mg , Quinine Dihydrochloride Injection 300 Mg/Ml, 2 Ml Ampoule , Temphos 50% Ec 5 Liter Pack , Malathion Technical 95%, 250 Kg , Deltamethrin 2.5% Wp, 25 Kg , Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) , Pyrethrum Extract 2% , Coupons For Hepatitis C Virus Genotype Testing (Pcr) , Coupons For Hepatitis C Virus Rna Viral Load (Pcr) € Svr , Coupons For Hepatitis Be Antigen Test , Coupons For Hbv Dna Quantitative Test(For Diagnosis Of Hepatits-B) , Molecular Biology Grade Water As Per Requirement , Screw Capped Storage Vial 2Ml (500 Vials) Per Pack 2 Ml , 100 Well Micro Tube Storage Box , Single Channel Variable Volume Micropipette 20-200 Ul , Rnase And Dnase Degradation Solution , Rnase And Dnase Degradation Solution Wipes , Anti Hemophillic Factor Ix Vial Injection Size 500 Iu , Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule , Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole , Deferiprone Tablet 500 Mg , Desferrioxamine Injection 500 Mg , Medroxyprogesterone Acetate Injection Ip (Dmpa ) 25 X 1X 1Ml (Contraceptive Injection For Im Use Only) , Quadruple Blood Bags 450 Ml (Hll) , Quadruple Blood Bag With Sagm 350 Ml (Hll) , Quadruple Blood Bag With Sagm 450 Ml (Hll) , Reagents Bovine Albumin 22% , Dacarbazine Injection 200 Mg, 10Mg/Ml Vial , Dacarbazine Injection 500 Mg , Epirubicin Injection 10 Mg, 2Mg/Ml Vial , Fluorouracil Injection 1 Mg , Gemcitabine Injection 200Mg, 100Mg/Ml Vial , Gemcitabine Injection 1000Mg, 10Mg/Ml Vial , Isophosphamide Injection 200Mg, 100Mg/Ml Vial , Tamoxifen Citrate Tablet 10 Mg , Actinomycin Injection 0.5 Mg , Thalidomide Tablet 100 Mg , Exemestene Tablet 1 Mg , Morphine Tablet 10 Mg , Morphine Tablet 30 Mg Special Repair , Buprinorphine Patch 5 Mg , Buprinorphine Patch 10 Mg , Buprinorphine Patch 15 Mg , Trastuzumab Injection 150 Mg , Trastuzumab Injection 450 Mg , Onco Bcg Injection , Mitomycin Injection 40 Mg , Bortezomib Injection 2 Mg , Ifosfamide Injection 1 Gm , Codon Set , Oxygen Tubing, Suction Tubing (Different Colours) , Grip Lock , Octopus Arc-Biannual Rate Contract Connector (Length 1-10 Cm 1.5*2.5, 2-10 Cm 1.5*2.8)Pur Vol- 0.57 Ml , Q-Way 6 Inches ,Sterlized Using Ethylene Oxide , Transpore 2 , Transpore 4 , Anti Diptheria Serum , Hepatitis B Vaccine (R Dna) I.P. , Urine Screening Through Dry Chemistry Rapid Testing Kit/Strips For Multiple Drug Uses:- 1. Morphine/ Opiates 2. Buprenorphine 3. Tramadol 4. D. Propoxyphene 5. Benzodiazepines Test Kit Kit (Urine Drug Kit) , Nicotine Patches , Tablet Vareniciline 0.5Mg , Tablet Vareniciline 1 Mg , Cbnaat Tb Cartridges - , Early Childhood Development (Ecd) Kit For Ashas - , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 6.5 Cm X 5 Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 15.5 Cm X 8.5Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 25 Cm X 10 Cm , (Pack Of 100) , Coutery Pad (Single Unit) , Chest Tube Drainage With Water Seal Bag No.28 , Chest Tube With Water Seal No.32 , Turp Loop , Craner Wire Splint , Bb Splint (Bohler- Braun) , Bed Side Pulley , Skeletal Traction , 3-0 Mesh For Lap Ingunal Hernia A)Right Side B)Left Side , Partial Absorble (10X6 Cm)Vicryl Mesh For Ipom , Stainless Steel Wire 26 G. Soft Isi/ Iso/Ce/Marked. , Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed , Denture Spirit-Surgical Spirit With Methyl Salicylate, Diethyl Phthalate And Caster Oil Dentured Alchol, 500 Ml Bottle(Covid) , Lox 10 % Spray 50 Ml , Cell Seaker , Right Angle Needle , Sickle Knife , Micro Scissors - Straight , Set For Stapedectomy , Micro Suction Tips Set Of 5 Different Sizes , Wire Speculum / Screw Speculum , Hydro Cannula , Phaco Machine Cassette , Lead Standard 12 Leads , Acquisition Mode (Simultaneous 12 Leads Acquisition) Samplin Rate 100 Hz, Ad Converter 24 Bits , Operation Mode Manual Auto , Rhtym 1 Channel 1 Minute, Memory 1000 Cases , Polarzing Volatage + 300Mv, Noise Leve 15U , Threshold 20Uv, Ac 100-240 V , 50 /60 Hz, Dc 14.4V 2500 Mah, 36.00 Wh , Inupt Mode Floating And Defibriliation Protection ( Ecg Machine) , Dialer , Chopper , Phaco Tip , Rhesis Forceps , Nuclear Express Or Hook , Conjuctival Scissor , Lims Forceps , Inj. Carpinol (Pilocarpine Nitrate Ip 0.5 %Iv) , Blurehex Dye , Needle No. 26 ½ , Phaco ( Tip & Sleeve) Alcon , Phaco Cassettes , Frost , Cement Spatula , Metal Cutting Bur , Composite Syring , Bond Adhesive , X- Ray Lead ( R & L) , Nucleic Acid Extr Silica Bead , Drill Bit 10 , Drill Bit 6 , Lignocaine Spray 10 % 10 Gm , Turp Set (Oblique Topline Telescope 30, Enlarged View, Diameter. 4Mm,Length 30 Cm, Autoclable .) , Chromic Catgut No. 1 Blunt Needle (Liver Suture) , Inj. Laxicard 50 Ml Iv , Inj. Methyldopa , Screw Removed Forceps Plies Type , Self Centering Forceps 12 , Self Centering Forceps 4 , Self Centering Forceps 6 , Semen Diluting Fluid 125 Ml (Nice) , Sensorcaine Injection 0.5% 20 Ml , Limss Forceps , Wire Veetis , Diluent 20000 Ml (Automated Haematology Analyzer) Three Part (Medonic M - Series M32 B Part Iii Cell Counter) That Prepares Blood Samples For Analysis By Creating An Isotonic Environment For Red Blood Cells And Platelets, And Also Helps In Lysing Red Blood Cells. It Is A Crucial Component For Accurate And Reliable Blood Cell Counts And Differentials , Lyse 5000 Ml (Automated Haematology Analyzer) Three Part (Medonic M - Series M32 B Part Iii Cell Counter) That Prepares Blood Samples For Analysis By Creating An Isotonic Environment For Red Blood Cells And Platelets, And Also Helps In Lysing Red Blood Cells. It Is A Crucial Component For Accurate And Reliable Blood Cell Counts And Differentials , Medonic M - Series M 32 B Con - Sol 3 Ml , 21 G 1 Needle (Dispo Van/ Hmd / Bd) , 23 G 1 Needle (Dispo Van/ Hmd / Bd) , Microscopic Cover Glass (English Glass) (Blue Star / Gem -Dx / Boroit) , Blood Bag Tube Sealer With Battery Backup , Sidox Fogging Agent , Lox 5 % Iv Injection , Mesh. Ethico Left Right 15 / 5 , Mesh. Ethico Left Right 7.5/ 5 , Nalbuphin Injection , Butadol Injection , Mercury Pure Triple Distilled (Dpi/Dentsply/Prevest) , Calcium Hydroxide , Paste System Based And Catalyst -Radiopaque (Septodent / Dentsply / Dpi) , Gum Paint (Dr. Reddy / Shofu) , Mini Plates Isi/ Iso/Ce/Marked. , Guide Wire Teflon Coated J Tip , Guide Wire Teflon Coated V Straight Tip , Gum Paint , Flowable Composite , Gates Glidden Drill No. 1 , Gates Glidden Drill No. 2 , Gates Glidden Drill No. 3 , Iopa Film Size 30 Mm X 40 Mm , Iopa Film Size 31 Mm X 41Mm , Air Rotor Spray Bottle , Dental Chair Covering Sterilized Cling Foil Rolls Isi/ Iso/Ce/Marked. , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) , Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution , Sgpt 5X20ml Erba , Crysta Gic , Suction Tip , Burr Cutting (Tungsten Carbide) ( 2Mm, 3 Mm, , 4 Mm, 5 Mm, 6 Mm, 7Mm) , Intralipid 20 % 10 Ml Inj. , Salmonella Kit (Antigen Types (O, H, Ah, Bh), Pack Sizes (E.G., 2+2X5ml, 4X5ml For 100 Tests), Requirement For Positive/Negative Controls, (Widal )Slide/Applicator Sticks, Storage At 2-8°C, Long Shelf Life (18-24 Mo), And Performance Features Like =98% Specificity & Rapid (=3 Min) Results For Slide Tests, Ensuring Reliable Typhoid Diagnosis. ) Arkray , Magna Pure 24 Total Na Isolation Kit, Pack Size-96(Covid) , Magna Pure 24 Processing Cartridge, Pack Size-48(Covid) , Magna Pure 24 Tip Ptark (Comes With Pierecing Tools)Pack Size-48(Covid) , Magna Pure Tip 1000 Ul, Pack Size-3840(Covid) , Framestrips With Flat Caps High Profile, Pack Size-120(Covid) , Magna Pure Sealing Foil,Pack Size-100(Covid) , Mplct Na Isolation Kit- Lysis/ Binding Buffer Refill, Pack Size-100Ml(Covid) , Framestrip With Flat Caps-Low Profile(Covid) , Magna Pure 96 External Lysis Buffer(Covid) , Light Cycler -480 Multiwell 11 Plate 96(Covid) , Light Cycler 8-Tube Strip Adapter Plate(Covid) , Manual Rna Extraction Kit-50 Test(Covid) (Mylab / Altona) , Tocilizumab Injection 400 Mg/20 Ml(Covid) , Lc Prep Lysi/Bind Buff Dna,Mbp , Dexamethasone 6 Mg Tablet(Covid) 6 Mg , Coronil Kit Coronil Kit Each Contains(80Tab+80Tab+20Ml) , Tocilizumab 80 Mg , Sars-Cov-2 Sequencing Kits Test Kit Kit , Corbevax Vaccine,10 Ml Vial , Direct Ldl 1X30/1X10ml Erba , Ppt 10Tu Arkray / Beacon , Absolute Alchol 99.95 % 5 Lt , Coupling Jar Glass , Coupling Jar Plastic , Esr Tube (Western Gren) Disposable , Thermal Paper For Bio Analyzer 1 X 1 , Slide Tray , Pti Uniplastin Quantitive Kit , Anti Ab 10 Ml , Reagent Bovine Albumin 22 % , Anti D Igg + Igm , 5 Second Test Result Chemical Bio Sensor Technology With Capillary System Having No Coding System (Automatic Calibration) With At Least 450 Test Memory. Memory Measuring Range Should Be 10-500 Mg/Dl. Should Be Standard (Aaa) Alkaline Battery/Li Ion Battery Operated With Lcd Size To Be At Least 50Mm (Diagonally).With ±5Variance. Strip Should Have Shelf Of Minimum 12 Month At Time Of Delivery Glucometer Should Be Isi/Usfda/Ce Certified/ Approved Product. Glucostrip (500 Strips With Meter) , Racked Filter Pipette Tips (Sterile) 20 Ul , Racked Filter Pipette Tips (Sterile) 100 Ul , Racked Filter Pipette Tips (Sterile) 200 Ul , Racked Filter Pipette Tips (Sterile) 1000 Ul , Filter Pipette Tips (Sterile) 200 Ul , Filter Pipette Tips (Sterile) 1000 Ul , Sensitivity Discs (Pbl /Himedia) , Ethanol 500 Ml , Dropper Plastic (Abdos/Tarson) 3 Ml , Glass Slide (1 * 100) Blue Star , Cmark , Crp One Test (Arkray/ Aggape/ Tulip) , Glycine 3 Ltr , Inoculating Loop 10 Mm With Holder , Zn Stain , Stragiht Wire With Holder , Cedar Wood Oil , Ph Meter , Sterile Swab Sticks , Spirit Lamp With Gas Cylinder , Glass Rods , Discarding Jar Plastic , H2o2 Reagent , Koh Reagent , Oxidase Strips , Pepton Water , Sterile Swab , Catalase Reagents , Anti Sensitivity Drugs Vancomycin , Anti Sensitivity Drugs Azitrhomycin , Anti Sensitivity Drugs Levlofloxacin , Anti Sensitivity Drugs Doxycylline , Anti Sensitivity Drugs Cefoxitin , Anti Sensitivity Drugs Amoxiclav , Anti Sensitivity Drugs Meropenum , Anti Sensitivity Drugs Pipertazobactum , Anti Sensitivity Drugs Aztreonam , Anti Sensitivity Drugs Gentamycin , Anti Sensitivity Drugs Ceftrixone , Anti Sensitivity Drugs Ceftazidime , Anti Sensitivity Clindamycin Pencillin , Anti Sensitivity Ampicillin , Anti Sensitivity Imiperum , Crp Latex 100 Test , Rf Latex 100 Test , (Copper Condenser, Anti-Rust Coating, Anti-Freeze Thermostat, White, ) 5 Years Comprehensive Warranty , Energy Rating: 3 Star. Annual Energy Consumption: 1464.72, 3 Star Window Ac 2 Ton , Gold Fin+ - Increase Durability, Ocean Black Protection, Ez Clean Filter; Low Gas Detection; 100% Copper Condenser; Hi Grooved Copper; Smart Diagnosis System; Comfort Air; Monsoon Comfort; Self Diagnosis; Auto Clean; On/Off Timer; Sleep Mode; Diet Mode Plus; Fan Speed Steps: 6 1.5 Ton 3 Star Split Ac , Hospimax Automated Blood Coagulation Analyzer - Pt Kit 280 Test (With Washer , Reagent R1, Roter, Cleaner & Control) , Hospimax Automated Blood Coagulation Analyzer - Aptt Kit 720 Test (With Washer , Reagent R1 , Roter, Cleaner & Control) , Hiv Protection Kit , Acetic Acid 99.9 % Pure 500 Ml Bottel , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria , Forceps Big , Forceps Small , One Strip Dengue Combo Test (Ns1 Igg Ogm) , One Strip Hiv-Hcv-Hbsag Combo Test , Hiv 1+2 And Syphillis Combo Test , Troponin T Test , Chikungunya Antibody Test , Elisa Plate Reader (Erba) , Elisa Plate Reader With Led (Athenese/ Meril) , Elisa Plate Washer (Erba) , Elisa Plate Washer (Athenese / Meril) , Urine Strip Analyzer , Hav (Elisa Kit) , Hev (Elisa Kit) , Leptospirosis (Elisa Kit) , Scrub Typhus Elisa Kit , Rcm Media (Ready To Use) , Agar / Agar Media (Ready To Use) , Test Tube Rack (Aluminium) , Slide Tray (Aluminum) , Nichrome Wire Loop , Grams Stain (Ready To Use) , Laboratory Forceps , Laboratory Tempreature Meter , 5-0 Polypropylene , Micirocentrifuge Tube Sterile 1.5 Ml , Sodium Hydroxide Pallets 500 Gm , Trisodium Citrate 500 Gm , Pottasium Dihydrogen Orthophosphate 500 Gm , Sodium Phosphate Monobasic Dehydrate 500 Gm , Pcr Tubes (0.2 Ml) , Maqintosh Sheet Reusable Size 10 Meter Good Quality , Durable, Waterproof, And Flexible Rubber Or Vinyl-Coated Fabrics Designed For Clinical , Sharp Container , Steam Indicator Strips , Biological Indicator Steam , Autoclave Tape , Stablizer 4 Kva Or Higher To Handle Up To ~12.5A Of Current, Or Around 2 Kva Specifically For Inverter Models. Key Specs Include A Working Range Of 160V-270V Or 130V-300V For Extreme Fluctuations, Digital Display, Time-Delay System, And High/Low Voltage Cut-Off. , Benzakonium Chloride Surface Disinfectant 1 Ltr , Non-Absorbable, Braided, Coated Green Polyester (Polyethylene Terephthalate) Suture Designed For High-Tension, Long-Term Tissue Support, Often Used In Orthopedic And Cardiovascular Surgery. It Features Excellent Knot Security, High Tensile Strength, And Is Typically 75Cm Or 90Cm In Length, With Various Needle Configurations Such As V-40 (48Mm) Or V-55 (55Mm). Ethibond No. 5 , Hmf Sachet , K -90 Catheter , Blood Agar Media 500 Gm , Maconke Agar Media 500 Gm , Nutrient Hinton Agar Media 500 Gm , Cled Media 500 Gm , Xld Media 500 Gm , Dca Media 500 Gm , Agar Powder 500 Gm , Pottasium Tellurite Media 500 Gm , Triple Sugar Iron Media 500 Gm , Motility Test Media 250 Gm , Nutirent Broth 500 Gm , Methyl Red Indicator 125 Ml , Kovacs Indole Reagent , Macconkey Broth Neutral Red (Double Strength) , Macconkey Broth Neutral Red (Single Strength) , Koh (Pottasium Hydroxide) Pallets , Oxidase Discks Packet (50/Pack) , Blood Culture Bottles 100 Ml , Antibiotic Octa Disc Rings (For Gp , Gn, Pseudomonas Uti, Pathogen , Sputum Pathogen) 10 / Pck , Antibiotic Sensitivity Reading Scale (Vernier Calipers) , Albert Stain A & Albert Stain B (Per Bottle 125 Ml) , Iodine Solution 1 Litre , Plastic Petri Dishes 90 Mm , Inoculating Nichrome Straight Wire , Inoculataing Nichrome Wire Loop , Bunsen Burner With Lpg Gas Supply , Plastic Discard Jars 2 Ltr , Electronic Balance Upto 30 Decimal Places For Culture Media , Digital Rectangular Laboratory Hot Plate Temperature Control , Pointed Tweezers , Incubator (Temperature & Time Regulated ) 18 X 18 X 18 , Vertical Autoclave Capacity 80 Ltrs , Autoclavable Bag 15 Kg , Autoclavalbe Bag 30 Kg , Filter / Absorbent Paper , Glass Slide Plain 76/26, 50 Pcs/ Pack , Cover Slip Glass 0.13 X 0.17 Thick, 18 X 18 Mm , 50 Pcks , Glass Rod Size 4 Feet , Dropping Bottles 120 Ml , Dropper 1 Ml , Antibiotic Octa Disc Rings For Culture Sensitivity Testing (For Bacteria Gram Positive, Gram Negative, Pseudomonas, Urine Pathogen, Sputum Pathogen) 10 Pack , Stool Container Specimen Cups With Spoon Lid 50 Ml , Rack For Stains , Refrigerator For Lab 200 Litre , Conical Glass Flask Capacity 1000 Ml , Conical Glass Flask Capacity 250 Ml , Plastic Measuring Cylinder Capacity 500 Ml , Plastic Measuring Cylinder Capacity 100 Ml , Test Tube Capacity 27 Ml , Test Tube Capacity 7 Ml , Test Tube Capacity 5 Ml , Test Tube Capacity 3 Ml , Test Tube Racks (18 X 150) For 27 Ml , Test Tube Racks (12 X 100) For 27 Ml , Test Tube Racks (12 X 75) For Ml Test Tube , Sterile Barrier Protection Between Operator And Equipment. This Cover Protects The Fluid Contamination During The Surgery. Easy To Draping And Maintenance. Minimize The Procedure Timings. Adhesive Patches And Tie Use For Tight Fittings. Easy To Operate With Sterile Hands During Surgical Procedure. Shrink Resistant Nature.C-Arm Cover , Bowie Dick Sheet , Chemical Indicator
Contract Date: Mar 19, 2026 Contract Value : 20.00 Lakh
Government Departments No of Bidders 4
11.
Defence #9609242 AOC
Tender For Repair, Maintenance And Replacement Of Ht Cables, Gods, Vcbs, Rmus, Transformers And Connected E And M Items At Af Stn Suratgarh; 1 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engineer-In-Charge. 2 All as per item No. 1 here-in-before but in PCC/floor/road 3 All as per item No. 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre 4 Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified. 5 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified. 6 M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniqueand necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure and sealing the end of pipe complete all as specified and directed. 7 M&L for laying GI Tubing light grade 100 mm dia for cable potection in road/ floor all as specified and directed 8 Supplying and laying ofsize 90 mm dia (OD-90 mm & ID-75 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 9 Supplying and laying ofsize 120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 10 Taking out HT/ LT cable of any size/ description from trenches/ floors/ road/ wall/ pipe/ pole and removing & reusefrom site incl making good the disturbed surfaces to match with existing surface all as directed. 11 Relaying/ Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to panel board/ VCBat existing places or provided by MES forcarrying to other location, upto 33000/11000 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 300 sqmm 3 core obtained from item No.10above with required aluminium cable lugs, heat shrink joints specified and directed.Note:The cableJoints and protection pipe and Earth work (if cable laying new rout)shall be meausred seperatly. 12 Supply, laying in trenches/ with pole, jointing and testing of HT 11 KV rated XLPE insulated, PVC bedded earth system stranded aluminium conductor cable 3 core, 95 Sqmm inclusive all incoming and out-going electric connections, complete all as specified and as directed. 13 All as per item No 12 above but of size 3 core 120 sqmm 14 All as per item No 12 above but of size 3 core 150 sqmm 15 All as per item No 12 above but of size 3 core 300 sqmm 16 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 17 All as per item No 16 above but joint of size 120 to 185 sqmm 18 All as per item No 16 above bu joint of size 240 to 300 sqmm 19 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 20 All as per item No 19 above butjoint of size 120 to 185 sqmm 21 All as per item No 19 above butjoint ofsize 240 to 300 sqmm 22 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 23 All as per item No22 above but straight through joint of size 120 to 185 sqmm 24 All as per item No 22 above but straight through joint ofsize 240 to 300 sqmm 25 S&F in replacement cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 33 KV, 3 core 300 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed. 26 All as per item No 25 above but indoor type joint 27 All as per item No 25 above but straight through type joint 28 Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.90m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge. 29 Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed. 30 S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator/ polymer including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33KV grade complete incl taking down old/unsv all as specified and directed. 31 Supply and fixing disc type insulators, porcelain vitreous white brown or green, 145mm hight and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 120 KN for11000 Volts /33000 volts (use suitable string ) with highest voltage capacity 12 KV including taking down existing cracked/unserviceable disc type insulator complete all as specified and directed. 32 Taking down old U/S GO switch any type and size from HT 2/4 poles structures. 33 S & FGang operated switch outdoor type 11000 Volts, 200 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 9 Nos., channel, knife blades, GI pipe medium grade 25 mm dia for operating mechanism worked from ground level , locking arrangement with handle all as specified. 34 S & FGang operated switch outdoor type 11000 Volts, 400 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 12 Nos. with dropout fuse set, channel, knife blades, GI pipe medium grade 40 mm dia for operating mechanism worked from ground level, locking arrangement with handle all as specified. 35 All as per item No 34 but for 33 KV 400 Amp, operating horizontal direction incl taking down old/unsvall as specified and directed 36 S&F in replacement expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 20 Amp incl taking down old/unsv fuse unit complete all as specifed and directed. 37 S&F in replacement HT 33 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 400 Amps incl taking down old/unsvcomplete all as specified and directed. 38 Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacingthe defective major spares parts including provn of minor bolts nuts etc all as specified and directed.Note: Major spare parts will be measured & paid seperately under relevant items of Sch-A 39 Supply only Male contact/ moving Contact Blade 40 Supply only Female contact/Fix Contact Jaw 41 Supply only Tinned copper Flexible jumper 200A/400 A 42 Supply only MS jumper carrier 43 Supply only Back Connector plate 44 Supply only Petroleum Jelly 45 Dismantling/ Taking down old unserviceable lightning arrestor 11 KV from HT 2/4 poles structures. 46 M&L for HT 11 KV lightening arrestor expulsion type having discharge capacity of 65 KA, suitable for 11 KV HT line includng making connection with existing GI earth wire. 47 S&F of lightning arrestors expulsion type complete with all fittings, suitable for 33 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester allcomplete all as specified and directed. 48 Supply and fixing of Jumper for HT OH Lines 33/11 KVbus system to GOD and GOD to DO Fuse unit with jumper made of aluminium conductorinsulated with colour coding, (Red Green , Blue) with all conneted item i.e nut bolt, U G clamps etc up to length of size 3 to 5 Mtr all as specified and directed by Engineer -in-charge. 49 Dismantling concrete poles/ struts of any size complete all as specified and directed. 50 Demolition of concrete (coping of PCC/ GI pole/ Road) of any description and in any position 51 Supply and erecting in true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacingcomplete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch A). 52 PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed. 53 PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed. 54 M&L for PCC 1:2:4 type B1 using 20mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for PCC/RCC/Steel tubular pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed. 55 M & L for scrapping of old painted surfaces of electric pole covered by dust and other depositedmaterials by cleaningwith wire cup brush on drill /grinderfromsteel tubular pole of length upto 11 metres including cross arms,bracing, clamps etc and painting with one coat of Epoxy zinc phosphate primer and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, all as specified & directed by Engineer-in-Charge. 56 M & L for scrapping existing deteriorated complete removal of old paint bywith wire cup brush on drill /grinderfrom the steel tubular 2 pole structure of 9.0-11.0 mtr height above ground levelwithout removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, including one coat ofEpoxy zinc phosphate primer to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed. 57 All as per Ser item No. 56 above but for 4 pole structure. 58 All as per Ser item No. 56 above but for 6 pole structure. 59 Dismantling ACSR or AAC conductor complete all as specified and directed. 60 Supply andfixing aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: -(a) 6/1 x 3.0- Ferret (b) 6/1 x 2.59- Weasel(c) 6/1 x 2.11- Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c)on Page 384 of SSR-2010 Part-II (Rates). 61 M& L for Stringing of ACSR conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 62 M& L for Stringing of GI cradle Guaredconductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 63 M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed 64 Supply and fixing PVC moulded LT Line separator suitable for 4 lines OH system. Make- Denson/Mex-well/JB/Jaipuriya brothers 65 Surface excavation over the areas around the substations not exceeding 45 cm depth and averaging 30 cm deep and getting outspoil inhard & dense soil including levelling the surface. 66 M&L forscreened river sand/ tibba filling on the levelled ground surface/ducts in sub stations/below 2 pole & 4 pole structures etc 67 M&L stone aggregate of size 35 to 40mm spreading over sand layerin the substation areas including proper leveling all as directed and shown at site. 68 M&L stone aggregate of size 20 to 25mm spreading over sand layer in the sub stations areas including proper levelling all as directed . 69 M&L taking out spreadedaggrgate of any size &sieving the aggrgate & dust/ sand & relaying the aggregate after sieving in the sub stations 70 M&L brick work with sub class B brick straight cured on plan exc 6m mean radious built in cm 1:4 71 Rendering/cement plastering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortor 1:4 finished even and smooth without using extra cement 72 S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk),forming holes of Fe 410-W (Gde E- 250) quality without any attachmen use for cable duct cover at substncomplete all as directed. 73 M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External)with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified. 74 Material and labour for fixing of display Board of 60cmx30cm forearth pit made out of 2 mm thick MS sheet welded on angle iron legs 0.75 mtr long (02Nos) of size 40x40x6mm duly embeddedin PCC block 1:2:4, type B-1, using gradedcrushedstone aggregate, of size 23x23x30cm fixed in ground including necessary earthwork. Display Board shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in- Charge. The following is to be written on the board:- (a) Earth Pit No. -(b)Connected To -(c) Checked on -(d) Next due date.-(e) Ohmic Value 75 Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge. 76 Supply and fixing of synthetic insulating matsuitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed. 77 Supply and fixingEarthing dischard rod(ISI Marked), extendable upto 18 feet height with rubber hand grip and suitable size copper wire suitable for working with 11 KV HT lines complete all as specified and directed. Make: Jaipuria/Rashtriya Electricals 78 Supply and fixAluminium thimble/lugs suitable for 50 sqmm to 95 sqmm XLPE cable all as specified and directed. 79 Supply and FixAluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed. 80 Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engineer-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule 81 Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting ofcable at both endafter removing carbon /burnt insulation part of cable by cutting refixing cable withnew cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge all as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per daywill be recoverd per complaint. 82 M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note: GI stripbeyond 7.5Mtr length from earth electrode shall be measured and paid separately). 83 All as per item No 82 above but with 4 mm dia GI wire as earthing lead andGI protection pipe 20mm dia medium grade. 84 M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item) 85 S&F earthing strip 32x6mm GI fixed to wall/pole/buried in ground /drawn in pipe complete. 86 S&F earthing strip 20x3.0 mm copperfixed to wall/pole/buried in ground /drawn in pipe complete. 87 S&F GI wire 4mm dia iron fixed to wall/pole/buried in ground /drawn in pipe complete. 88 S & F Danger notice plate for HT poles size 1.6 mm thick mild steel sheet vitreous enemelled white letter figures and converntionl skull and bones maked in red colour with MS clamp of flate iron 25X3mm size, bolts, nuts, size of plate 25 X20 Cm complete all as directed by Engineer-In-Charge. 89 Dismantling unserviceable any size of cross arms from pole /structures/anti-climbing device etc complete allas specified and directed. 90 M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engineer-In-Charge. 91 M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed. 92 Cutting/trimming of tree branches under OH LT/HT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers smal bushes etc of under OH line upto 60 mitre each span complete all as specified and directed.Note: Materials/T&P like Axies, Daw, rope and the like will be provided by the contractor without any extra cost to the Govt. 93 M&L for stay assembly complete with MS stayplate 300x300x6mm thick galvanized stay rodnot less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I.Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be measured and paid separately under relevant items. 94 M&L for Galvanised stay strand, size 7/4mmcomplete. 95 M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete. 96 Overhauling/ servicing /calibration of HT VCB 400/630 Amps 33 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v)Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare parts shall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 97 Overhauling/ servicing /calibration of HT VCB 400/800 Amps 11 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v) Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare partsshall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 98 Supply and fixing in replacement microprocess numerical relay for 33/11 KV VCB tripping system ( 03 Over Current/02 O/C , 01 Earth Fault and high set instantaneous protection in single unit) suitable for opration on 24V DC-110V DCall as per Model No CGI14N/CGI4C of Make: Crompton Greaves or equivalent in AREVA(Note:ifExisting relays are of Electromagnetic type, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 99 Supply and fixing in replacement Ammeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 100 Supply and fixing in replacement voltmeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh(Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 101 M & L for Vaccum Interrupter type WL-33379 or as per exixtingsuitable for 11 KV VCB Panelcomplete all as specefied and directed. 102 M & L for Isolating contact assembly 400/800 Amps with complete set of contact (set of six) suitable for 11 KV VCB Panelcomplete all as specefied and directed. 103 Supply and fixing in replacement indicator lamp assembly 24V DC in (Red,Yellow, White, Green & Blue colour) for HT panels complete all as specified and as directed. 104 Supply install, testing and commissioning in replacementof Power packunit input voltage 90-270 Volts and out put voltage 24 Volts DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unitcomplete all as specified and as directed 105 Supply install, testing and commissioning in replacement of Power packunit input voltage 110 Voltage and out put voltage 24 Volt DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed 106 Supply and fix Motor cut off switch complete all as specified and directed 107 Supply and fix ZZ Switch complete all as specified and directed 108 Supply and fix HRC Kit kat fuse 2A, 4A,6A ,10A & 20 A complete all as specified and directed 109 Supply and fix Closing coil 24V DC complete all as specified and directed. 110 Supply and fix Tripping coil 24V DC complete all as specified and directed 111 Supply and fix of Multifunction meter (V,A,P,PF) for 11 KV VCB as per existing sample complete all as specified and directed. 112 Supply and fix of Big gear and small gear set complete all as specified and directed. 113 Supply and fix of TNC switch 11 KV/33 KVpanel complete all as specified and directed. 114 Supply and fix Segment gear complete all as specified and directed. 115 Supply and fix of 11 KV Spring charging motor 220V AC/DC complete all as specified and directed. 116 Supply and fix Motor & Gear assembly 110V DC and 220 ACfor 11 KV VCB Panelcomplete all as specefied and directed. 117 M&L for painting to VCB,Fire stand post ,duct plate etc atinstallations with two coats of synthetic enamel paint after making the suface free from oil/grease/rust and applying a coat of red oxide primer complete including writing details as per directed like as SM Nos/feeder detail etc. all as specified and as directed. 118 S & F in repair Aux relay Buch/WTI/OTIfor 11 KV VCB panel ,Auxiliary supply 24Volt DC as per existing complete all as specified and directed. 119 S & F Cast resin type 11KV VCB three phase current transformer having ratio 100+50/5+5Aas per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second 120 S & f 11KV VCB three phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 121 S&F in replacement HT fuse wire upto 60 amp asper site requirement mounting on insulator of 2 Pole/4 Pole structure complete with fused barrelfor 11 KV complete all as specifed and directed. 122 Disconnecting, opening of HT Capacitor bank of any description and any make of rating 11 KV indoor capacitor switching APFC paneland outdoor capacitor bank type with automatic/manual control having output 2400 KVAR (Step rating proposed : 400 KVAR x 2+800 KVAR x 2 desired 0.99) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etcand replacement of unserviceable parts with new one, reassembling the HT Capacitor Bankafter overhauling/ servicing and its testing complete all a specified and directed. Note:Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch A as supply only 123 Spply only HT HRC Fuses suitable for 11 KV, 400 KVAR complete all as specified and directed. 124 Spply onlyHT HRC Fuses suitable for 11 KV, 800 KVAR complete all as specified and directed. 125 Spply only NDVR Relay suitable for 400 KVAR step complete all as specified and directed. 126 Spply only Contactor coil 127 Spply only Copper bus bar 50x10 mm length 1 mtras per site requirement 128 Dismantling and taking down by removing HT and LT connection of indoor /outdoor type 11/0.433 KV transformer of capacity up to 200 KVA from existng platform/4 Pole/inside sub station Lowering the same carefully and shifting to other location within Air force station(both tech & resdential) as directed by Engineer-in-charge with and including re-installation by means of arrangement and testing and including additional/alterationfoundation according manufactures complete all as specified and directed . Note : (a) Installation of transformer , testing and connecting the both HT/LT cables , commissioning of transformer after checking voltage and loading at full load shall deemed to be included in quoted rates .(b) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation, the rent and foundation for additional/alteration shall deemed to be included in the quoted rate. 129 All as per srl item No128, abovebut capacity of transformer more than200 KVA andupto 500KVA complete all as specified and directed . 130 Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity 100 KVA to 250 KVA, after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper/aluminium wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oilwill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 131 All as per Srl item No 130 above but of capacity 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed. 132 S & F in replacement brass terminal rod with nuts , boltswasher and bushing suitable for HT and LT side of the transformer of any make and capacity upto 200 KVA complete all as specified and directed . 133 All as per srl item No132, abovebut capacity of transformer more than200 KVA andupto 630KVA complete all as specified and directed . 134 S & F in replacement tap changing switch suitable for operation on 11/0.433 KV distribution transformer with tappings on 2.5% , 5% and 7.5% on requirement basis for upto 630 KVA capacity transformer complete all as specified and directed . 135 Supply and Filling in replacement superior quality silica jel inside the breather assembly and fixing properly with transformer complete all as specified & directed. 136 S & F in replacementoil valve for drain out/filling in screwed both ends with iron wheel head suitable for transformers up to 200 KVA capacity complete all as specified anddirected. 137 All as per srl item No 136, abovebut capacity more than 200 KVA andupto 630 KVA complete all as specified and directed . 138 M & L for fabrication HT / LT side box covers made of bakelite sheet10 mm thickness with proper nuts bolts incl cutting sheet to required size , drilling holes for nuts/bolts etc complete allas specified and directed. 139 S & F in replacement oil temperature gauge 0 -120 degree analogue dial type for transformer complete all as specified & directed 140 M & L for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto65 KV/40KV (RMS) atstandardgap of electrodes 2.5 mm for one minute in 33 KV/11 KV transformer capacity 3 MVA TO 5 MVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed.Note:(i) Contractorwill have to arrange the dehydration machine and transformer oil dielectric strength testing equipmentas mentioned and same shall be deemed to be included in the item rate quoted.(ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item. 141 Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT33 KV transformer/HT 11 KV AVR transformer/11 KV distribution transformer all as as specified and directed. 142 Supply only super enameled copper conductor wire of suitable gauge and size as per requirement for rewinding of 33/11/0.433 KV power/distribution transformer complete all as specified and directed . 143 Supply only super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed. 144 Supplying and fixing in replacement, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers. 145 All as per Serial item No144 here-in-before butcapacity 200 KVA to 315 KVA 146 All as per Serial item No 144 here-in-before but capacity 400 KVA to 630 KVA 147 Supplying and fixing in replacement, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andconnecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers and reconnection 148 All as per Serial item No 147 here-in-before but200 KVA to 315 KVA 149 All as per Serial item No 147 here-in-before but 400 KVA to 630 KVA 150 Supplying and fixing in replacement,all unserviceable gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 200 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.(i) The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washersetc. (ii)Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. 151 All as per Serial item No 150 here-in-before butmore than 200 KVAand up to 630 KVA 152 S & F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers,capacityupto 200 KVA complete all as specified and directed. 153 All as per Serial item No152 here-in-before butcapacity more than 200 KVA and upto 630 KVA 154 Supply and fixing in replacement 3mm thick Sheet glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer upto capacity 630 KVA complete all as specified and directed. 155 Supply and fixing in replacement thermometer of transformer upto capacity 630 KVA complete all as specified and directed. 156 M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type)according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 160KVA transformer outdoor/indoor complete all as specified and directed 157 All as per item No: 156 but capacity above 200 KVA and upto 630 KVA. 158 Repair to distribution Power transformer 33/11 KV outdoor type of capacity 3 MVA to 5 MVA , after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete,replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of all gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable HT bushes, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the Transformer and TTRtesting with complete all as specified and directed by Engineer-in-Charge. Note :- Transformer oil /Winding wirewill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 159 Supply and fix inreplacement WTIrelay suitable for 3.15 MVA /5 MVA transformer control panel completeall as specified and directed by Engr-in-charge. 160 Supply and fix inreplacement OTI relay suitable for 3.15 MVA/ 5 MVA transformer control panel complete incl taking down unsv all as specified and directed by Engr-in-charge. 161 Supply and fixinreplacement Mastertripping relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 162 Supply and fixinreplacement Differntial protectionrelay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 163 Supply, fixing and testingin replacement Buchholz relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 164 Supply and fix inreplacement Over/Under voltage protectionrelay with display suitable for 3.15 MVA/5 MVA transformer/ 33 KV VCBcontrol panel complete with testing and calibrationincl taking down unsvall as specified and directed by Engr-in-charge. 165 Supply & Fixmarshaling box complete with all sensor/Meter/indicatorfor protection of winding temprature , oil temprature etc suitable for 5 MVA/3MVA Transformeror as per existing incl connection andtaking down unsv all as specified and directed. 166 M&L for overhauling of the 11 kV Automatic Voltage Regulator (AVR) involves a comprehensive inspection, cleaning, testing and restoration process to ensure reliable performance and accurate voltage regulation. The scope includes the following :-(a) Initial Inspection: Visual and mechanical inspection of the AVR and associated components to assess overall condition and identify faults or degradation.(b) Dismantling: Safe removal and disassembly of the AVR unit including checking connections, terminals and internal assemblies.(c) Cleaning: Removal of dust, oil, moisture, and other contaminants using appropriate cleaning agents and techniques.(d) Component Testing: Electrical testing of control circuits, sensing mechanisms and regulating components to detect wear, drift or failure.(e) Replacement of minorParts: Replacement of defective or worn-out components such as resistors, capacitors, relays, or control cards with compatible, high-quality spares. 167 (f) Reassembly and Calibration: Reassembling the AVR and performing calibration to manufacturer specifications for optimal voltage regulation performance.(g) Final Testing: Functional testing under simulated or actual load conditions to verify stability, response time and output regulation.(h) Reporting: Preparation of a detailed service report including findings, actions taken, test results and recommendations.Note :- (i) Restore the AVR to its original working condition with improve efficeincy andreliable operation of the 11 KV system.(ii) The above work shall be carried out by the authorised manufacturer and rate for the same are included in this item. Nothing shall be paid extra on this account. Note :- Following Major spare parts will be measured & paid seperately 168 Supply only AVR Carbon roller assemblycomplete all as specified and directed 169 Supply only tag and tail assey AVRcomplete all as specified and directed 170 Supply only B4c limitt switchcomplete all as specified and directed 171 Supply only PCB sensing relaycomplete all as specified and directed 172 Supply only Motor 40 KG with Gearcomplete all as specified and directed 173 Supply only Delta change flip flopcomplete all as specified and directed 174 Supply only TDR 240 V AC complete all as specified and directed 175 Supply only Aux Contactorcomplete all as specified and directed 176 Supply, installation, testing and commissioning of 11 kV, 630 Amp, 3 Pole, Outdoor Type Load Break Switch (LBS) with manually operated gang mechanism, suitable for breaking load current under normal service conditions, complete with insulators, arcing horns, operating mechanism, earth blades, padlocking arrangement and all other necessary accessories for safe and efficient operation ,The LBS shall be mounted on hot dip galvanized steel support structure duly fabricated with base frame, operating pipe, crank and handle, including providing and casting of cement concrete foundation in 1:3:6 type C-2 (using 40 mm graded stone aggregate) with necessary excavation, formwork, curing and finishing smooth, including grouting of bolts and painting of steel structure with two coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Contract Date: Feb 16, 2026 Contract Value : 31.31 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
12.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
14.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
15.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
16.
Health and Family Welfare #9300981 Technical Bid
Tender For Supply Of Dental Items , Ortho Implants And Other Items , Medicins And Lab Items , Inj. Loxcard 50 Ml 2% , Inj. Clonidine 30 Mg , Inj. Clonidine 150 Mg , Inj. Dexmedetomidine 100 Mcg , Prolene 3 - 0 , Abdominal Drainge Kit , Inj. Butorphanol Tartirate 1Mg/Ml , Noramal Saline 3 Ltr , Inj. Betaloc 5 Mg , Inj. Cardarone 3 Ml , Brain Circuit , Irregatton & Aspiration Cannula No. 23 G , Hydro Direction Cannula , Laryngcal Mask Airway Size No. 3 , Curved Conjuctive Scissor , Nasopharngeal Air Way No. 6 , Nasopharngeal Air Way No. 7 , Nitrous Oxide Inhalation , Chlorpheniramine Tablet 4 Mg , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Levamasole Tablet 50 Mg , Levamasole Tablet 150 Mg , Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent , Cloxacillin Capsule 500 Mg , Methyldopa Tablet 250 Mg , Methyldopa Tablet 500 Mg , Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle , Betamethasone Dipropionate Cream 0.1% W/W , 5 Gm , White Petrolatum Jelly 100 %, 50 Gm Jar , Pyridium Tablet 200 Mg , Pilocarpine (Hydrochloride Or Nitrate) Eye Drops 2 %, 5 Ml Squeeze Vial , Ichthoimol Glycerine Solution 10 Ml Vial , Mometasone + Terbinafine Ointment 15 Gm , Methyl Ergometrine Tablet 125 Mcg , Olanzapine Tablet 20 Mg , Perampenel 2 Mg , Atomoxitine Capsule 10 Mg , Formoterol (6Mcg) + Budesonide (200Mcg) (Foracort Inhaler) , Chloroquine Phosphate Tablet 250 Mg, Equivalent To 155 Mg Chloroquine Base , Primaquine Tablet 15 Mg , Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg , Weekly Iron Folic Acid Tablet Each Tablet Containing 60 Mg Elemental Iron+500 Mcg Folic Acid, Sugar Coated ,Blue Colour , Iron And Folic Acid Tablet ( Wifs Junior ) Containing Dried Ferrous Sulphate Ip Equivalent To Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet. Tablet Are Sugar Coated And Pink Coloured Tablets With Only Edible Colours Used Tablet Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet , Waterproof Bed Sheet , Adult Diapers , Eatraction Forcep Set , Elevator Set , Peristel Elevator , Kidney Tray , Plastic Filling Instrument , Ball Burnisher , Steel Cemant Spatula , Artery Forceps , Hand Sealer Set , Glass Slab , Weighing Scale Digital Adult One Year Warranty , Weighing Scale Digital Paediatric One Year Warranty , Stadiometer , Measuring Tape , Thermometer Digital , Digital Bp Appratus Automatic One Year Warranty , Cotton Swabs , Sims Speculum - Metal , Cuscos Speculum (Large / Medium / Small) Metal , Spot Examination Lamp , Ayres Wooden Spatula , Endocervical Cytobrush , Combi - Brush , Coplin Jar Glass , Coplin Jar Plastic , Stethoscope Good Quality Isi Certified , Cyclophosphamide Tablet 50 Mg , Etoposide Capsule 50 Mg , Lenalidomide Tablet 10 Mg , Tamoxifen Citrate Tablet 20 Mg , Dexamethasone Tablet 4 Mg , Dexamethasone Tablet 8 Mg , Temozolamide Tablet 250 Mg , T- Connector , Y- Connector For 8-10 Mm , Uro Bag (Neonates)- 100 Ml , Surfactant- Survanta(Synthetic)(25 Mg/1Ml), Exosurf (Bovine) , Chest Drain (Adults) , Td Vaccine , Nicotine Pastilles 2 Mg , Nicotine Pastilles 4 Mg , Tablet Buspirone 5 Mg , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 15Cm X 15 Cm Square (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging , Potassium Peroxomonosulphate 50% W/W Containig Aldehyde Free Disinfectant , 5 Kg , Anterior Chamber Kellmann Multi Flex 4 Point Fixation Type Optical Diameter 6Mm,Overall Length 12.5 Mm, Dioptric Range 10D To 30 D , I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye) , Guide Wire Teflon Coated J Tip , Guide Wire Teflon Coated V Straight Tip , Naocl 5.25% Solution Isi/ Iso/Ce/Marked. , Topical Fluoride Apf Gel 1.25% , T Plus Eye Drops , Paracine Eye Drop , Gatiquin - P Eye Drop , Tropicamide Eye Drop , Gatiquin - P Eye Drop , Novacide Solution , Two Slot Easy & Convenient Operation For Destroying Needles & Syringes, Where Needle Burns Electrically And Syringe Is Cut Manually Using Sharp Steel Blade Within Seconds. Economical, Sturdy, Simple To Operate Healthcare & Surgical Machine Consuming Low Power. Powder Coated Strong Metal (Copper) Body With Shock-Proof Main Circuit Breaker And Provision Of On/Off Switch With Pilot Lamp. , Inj. Vitamin D3 / Cholecalciferol(600000.0 Iu/Ml) , 1 Annual Periodical Maintenance Of Vitamin C 150 Mg/1.5 Ml, 2 Amps Of Vitamin B12 2500 Mcg, Folic Acid 0.7 Mg, Niacinamide 12 Mg/1 Ml (Eldervit Inj.) , Knee Drape , Silver Alloy Non-Gamma-2 Lathe Cut Alloy (Dpi/Dentsply/Prevest) , Eugenol (Dpi/Dentsply/Prevest) , Zinc Oxide Powder (Dpi/Dentsply/Prevest) , Pit & Fissure Sealant ( 6 Ml Bottle) Solution , Cavity Varnish 5% Sodium Fluoride (Dentsply / 3 M / Dpi) , Zinc Phosphate Cement , Powder And Liquid (Harvard / Prevest / Dpi) , Formocresol Formalin, Cresol Glycerin ,Formocresol Formalin Bp 20% V/V , Cresol Ip 32% V/V , Glycerin Ip Qs (Prevest / Shofu/ Dpi) , Air Rotor Spray Bottle (Nsk/ Kavo / Confident) , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) (Prevest/ Blossom) , Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution (3 M / Ivoclar/ Shofu) , Electronic Dental Chair With Adequate Accessories (Handpieces, Compressor,Three Way Syringe , Instruments For Manual Cleaning Of Teeth (Api / Samit / Gdc) , Ultrasonic Scaler (Woodpacker / Satelac/ Ems) , Polishing Kit (Shofu/ Dentsply/ Coltene) , Dental X-Ray Unit (Tecnomac / Trophy / Gomax) , Light Cure Gun (Woodpacker / 3 M / Unicorn) , Extraction Forceps (Adult) (Gdc/ Api/ Samit) , Extraction Forceps (Pedo) (Gdc / Api/ Samit) , Restorative (Filling) Instruments (Gdc / Api/ Samit) , Three Way Syringe , Spoon Excavator (Gdc / Api/ Samit) , Fluoride Standard 100 Ppm (Orion) 475 Ml , Hybrid Composite Resin For Anteriors (Shofu/Coltene/3M) , Mineral Trioxide Aggregate (Angulus/Dentsupply/3M) , Petroleum Jelly , Dycal (Septodent/Dentsupply/3M) , Suction Tips Disposable , Orafill-G (Prevest) , Glass Slab , Kidney Trey , Chetal Forcep , Pmt Set (Gdc / Api/ Samit) , Cement Spatula (Gdc / Api/ Samit) , Bone File (Gdc / Api/ Samit) , Surgical Scissor (Gdc / Api/ Samit) , Pain Off Liquid , Glass Bead Sterlizer , Elevator Straight (Gdc / Api/ Samit) , Glass Ionomer Cement- Type-Ix (Gc Fuji/Shofu/3M). , Cryer Elevator (Gdc / Api/ Samit) , Hockey Stick Elevator (Gdc / Api/ Samit) , Luxator Set (Gdc / Api/ Samit) , Uv Chamber , Gutta Percha 17 4% (Dentsply / Diadent/ Meta) , Gutta Percha 20 4% (Dentsply / Diadent/ Meta) , Gutta Percha 25 4% (Dentsply / Diadent/ Meta) , Gutta Percha 20 6% (Dentsply / Diadent/ Meta) , Endorotary Files Orifice Opener (Dentsply / Diadent/ Meta) , Endorotary Files Glide File (Dentsply / Diadent/ Meta) , Endorotary Files 20 4% 21Mm (Dentsply / Diadent/ Meta) , Endorotary Files 20 4% 25Mm (Dentsply / Diadent/ Meta) , Endorotary Files 25 4% 21Mm (Dentsply / Diadent/ Meta) , Endorotary Files 25 4% 25Mm (Dentsply / Diadent/ Meta) , Endorotary Files 20 6% 25Mm (Dentsply / Diadent/ Meta) , 7Th Generation Bonding Agent (3 M / Coltene/ Shofu) , Sodium Hypchloride 5 Ltr 10 % Packing , Diamond Burs Tr 13,Br 41, Straight ( Mani) , K-Files Assorted 21Mm 15No. (Mani/Dentsupply) , K-Files Assorted 21Mm 20No. (Mani/Dentsupply) , K-Files Assorted 21Mm 25No. (Mani/Dentsupply) , K-Files Assorted 21Mm 30 No. (Mani/Dentsupply) , K-Files Assorted 21Mm 15-40 No.. (Mani/Dentsupply) , K-Files 25 Mm 15-40 No. (Mani/Dentsupply) , K-Files Assorted 21 Mm 10No. (Mani/Dentsupply) , K-Files 21Mm 8 No. (Mani/Dentsuply) , Guttapercha Point No. 15-40 /45 -80 (Dentsply / Diadent / Meta) Hey Are Radiopaque, Biocompatible, And Come In Standardized Lengths To Fit Various Canal Depths. , Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer , Trey For Instruments , Dental Rvg (Vatec / Carestream/ Satelac) , Endomotor With Apex Locator (Nsk / W & H / Dentsply) , Arch Bar ( Orthomax/Samit/Dentsuply) , Ss Wire Gauge 26 (Orthomax/Samit/Dentsuply) , Ss Wire Gauge 28 (Orthomax/Samit/Dentsuply) , Rotary Gp 30 # 4 % , Rotary Gp 25- 40 # 4 % , Guttapercha Point No. 15-40 /45 -80 (Dentsply / Diadent / Meta) Hey Are Radiopaque, Biocompatible, And Come In Standardized Lengths To Fit Various Canal Depths. , Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer , Trey For Instruments , Dental Rvg (Vatec / Carestream/ Satelac) , Endomotor With Apex Locator (Nsk / W & H / Dentsply) , Physiodispenser (Nsk, W&H/ Merarhon/Woodpacker) , Dental Implant Kit (Ossteum /Denteum/ Noris/Addin) , Dental Implant Different Sizes(Osstem/Nobel Biocare/ Addin) , Abutment (Straight/Angulated) (Osstem/Nobel Biocare/ Addin) , Gingival Former (Osstem/Nobel Biocare/ Addin) , Dental Bone Caliper (Osstem/Nobel Biocare/ Addin) , Distal End Cutter (Long Handle (Eltee/Jj Ortho/North American)) , Flush End Distal End Cutter (Eltee/Jj Ortho/North American)) , Wingart Pliar (Eltee/Jj Ortho/North American) , Methews Pliar (Eltee/Jj Ortho/North American) , Wire Tucker (Eltee/Jj Ortho/North American) , Plc (Soft Ligature Wire Cutter , Hard Wire Cutter (Gdc/Jj Ortho) , Torqueing Pliar ( Male) (Jj Ortho/ Modern Ortho) , Torqueing Pliar (Female) (Jj Ortho/ Modern Ortho) , Buccal Tube Holder (Jj Ortho/ Modern Ortho) , Bracket Holder (Modern Ortho/North American) , Bracket Gauze Set (Jj Ortho/ Modern Ortho) , D-Bonding Pliar (Cat/Jj Ortho) , Delarosa Pliar (Jj Ortho/ Modern Ortho) , V- Band Forming Pliar (Gdc/Jj Ortho) , Moons Cutter (Gdc/Jj Ortho) , Three Jaw Wire Bending Pliar (Gdc/Jj Ortho) , Tweed Pliar (Eltee/Jj Ortho/North American) , Crimpable Hook Pliar (Eltee/Jj Ortho/North American) , Curved Hoe Pliar (Eltee/Jj Ortho/North American) , Band Removing Pliar (Eltee/Jj Ortho/North American) , Adams Pliar (Eltee/Jj Ortho/North American) , Wire Syncher (Eltee/Jj Ortho/North American) , Lite Composite (Ortho Organiser) , Ortho Solo Primer (Ortho Solo/ Ortho Organiser) , Metal Brackets (O22, Mbt) (Ortho Organiser) , Buccal Tube (Ortho Organiser) , Molar Band With Buccal Tube (Ortho Organiser) , Band Pusher (Ortho Organiser) , Etchent , Cheek Retracter (Ortho Organiser) , Modules (Ortho Organiser) , E Chain Closed (Ortho Organiser) , Ligature Wire ( Oo9, 010) (Ortho Organiser) , Orthodontic Wire (Niti) (Ortho Organiser) , Orthodontic Wire (Ss) (Ortho Organiser) , Tma Wire Straight (Ortho Organiser) , Mini Implants (Sk Surgical/ Favanchor) , Mini Implant Screw Driver (Sk Surgical/ Favanchor) , Rail System All Sizes (Ao / Sorat / Image) , Compression Distraction Unit (All Sizes) (Ao / Sorat / Image) , End Clamp (Ao / Sorat / Image) , Central Clamp (Ao / Sorat / Image) , Swivel Clamp (Ao / Sorat / Image) , Allen Key (Ao / Sorat / Image) , 6.5 Mm Taper Cut Schanz Pins (All Size) (Ao / Sorat / Image) , Ilizarov Half Rings (All Sizes) (Ao / Sorat / Image) , Ilizarov Wires (Trocar Tip & Bayonet Tip) 1.8 Mm (Ao / Sorat / Image) , Oilve Wires (Ao / Sorat / Image) , Male And Female Post (All Sizes) (Ao / Sorat / Image) , Washers (All Sizes) (Ao / Sorat / Image) , Rancho (All Sizes) (Ao / Sorat / Image) , Conical Washers (Ao / Sorat / Image) , Ilizarov Plates (All Sizes) (Ao / Sorat / Image) , Hinges (Ao / Sorat / Image) , Bolts (All Sizes) (Ao / Sorat / Image) , Nut (All Sizes) (Ao / Sorat / Image) , Wire Fixation Bolts (Side) (Ao / Sorat / Image) , Wire Fixation Bolts (Centre) (Ao / Sorat / Image) , Angled L Spanners (Bolt Head And Nut Shape) (Ao / Sorat / Image) , Precontoured Distal Fibular Plates (All Sizes) (Ao / Sorat / Image) , One Third Tubular Plate (All Sizes) (Ao / Sorat / Image) , Semi Tubular Plate (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Dcp (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Lc Dcp (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Lcp (All Sizes) (Ao / Sorat / Image) , 3.5 Mm Recon Plate (Locking & Non Locking) All Sizes (Ao / Sorat / Image) , 3.5 Mm Cortical Screw (All Sizes) (Ao / Sorat / Image) , 4.0 Mm Cancellous Screw (Solid) With Washer , Partially Threaded (16 Mm, 32 Mm All Sizes) (Ao / Sorat / Image) , 4.0 Mm Cancellous Screw (Cannulated) With Washer , Partially Threaded (16 Mm, 32 Mm All Sizes) (Ao / Sorat / Image) , 3.5 Mm Cortical Locking Head Screw (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Broad Lcdcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Narrow Lcdcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Broad Lcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Narrow Lcp (All Sizes) (Ao / Sorat / Image) , 4.5 Mm Cortical Screw (All Sizes) (Ao / Sorat / Image) , 6.5 Mm Cancellous Screw Solid With Washer (Fully & Partially Threaded , 16 Mm , 32 Mm , All Sizes) (Ao / Sorat / Image) , 6.5 Mm Cancellous Screw Cannulated With Washer (Partially Threaded , 16 Mm , 32 Mm , All Sizes) (Ao / Sorat / Image) , 5.0 Mm Cortical Locking Head Screw (All Sizes) (Ao / Sorat / Image) , Proximal Femoral Locking Plate (All Sizes) (Ao / Sorat / Image) , Dhs Plate (Standard Barrel) (Ao / Sorat / Image) , Dhs Plate (Short Barrel) (Ao / Sorat / Image) , Richard Screw (All Sizes) (Ao / Sorat / Image) , Dcs Plate (All Sizes) (Ao / Sorat / Image) , 95 Degree Angle Blade Plate (Condylar Blade Plate) 95 Degree (With All Sizes Blade Length) (Ao / Sorat / Image) , Osteotomy Blade Plate (120 Degree) ( 65 Mm, 75 Mm, 85 Mm) (Ao / Sorat / Image) , Distal Femoral Lcp (All Types , All Sizes , With Screws) (Ao / Sorat / Image) , Proximal Tibial Locking Hockey Plate (All Sizes , With Screws) (Ao / Sorat / Image) , Proximal Tibial Raft Plate System (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Reconstruction Plate Locking & Compression For Pelvie Reconstruction (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Proximal Tibial Postero Medical Locking Plate With Screws Of All Types (3.5 Mm) (Ao / Sorat / Image) , Proximal Tibial T Plates (Locking & Non - Locking ) With Screws Of All Types , All Sizes (Ao / Sorat / Image) , Proximal Tibial L Plates (Locking & Non - Locking ) With Screws Of All Types ,Both Sided, All Sizes (Ao / Sorat / Image) , Distal Tibial Malleolar Locking Plate (All Sizes, With Screws) (Ao / Sorat / Image) , Distal Tibial Metaphyseal Locking Plate (All Sizes, Both Sides , With Screws) (Ao / Sorat / Image) , Distal Tibial Anterolateral Locking Plate (All Sizes, Both Sides , With Screws) (Ao / Sorat / Image) , 3.5 Mm Precontoured Clavicular Plate (All Sizes, With Screws) (Ao / Sorat / Image) , Clavicle Hook Plate (All Sizes, With Screws) (Ao / Sorat / Image) , Proximal Humerus Locking Plate (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Distal Humerus Lateral Column Precontoured Locking Plate (All Sizes , Both Sides , With Screws) (Ao / Sorat / Image) , Distal Humerus Medical Column Precontoured Locking Plate (All Sizes , Both Sides , With Screws) (Ao / Sorat / Image) , Distal Humerus Extra Articular Precontoured Locking Plate With Screws Of All Types (All Sizes , Both Sides , With Screws) (Ao / Sorat / Image) , Precontoured Radial Head Plate With Screws Of All Types (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Proximal Ulnar Precontoured Locking Plate With Screws Of All Types (All Sizes, Both Sides, With Screws) (Ao / Sorat / Image) , Distal Radius Precontoured Locking Plate (With And Without Varialbe Locking Option) All Sizes Both Sides , With Screws) (Ao / Sorat / Image) , Herbert Cannulated Headles Screws (All Sizes) (Ao / Sorat / Image) , Femur Interlocking Nail With Locking Bolt (All Sizes) (Ao / Sorat / Image) , Proximal Femoral Recon Nail (All Sizes) (Ao / Sorat / Image) , Proximal Femoral Nail 0 Helical Blade Screw For Femoral Head (All Sizes) (Ao / Sorat / Image) , Tibial Interlocking Nail (All Sizes) (Ao / Sorat / Image) , Tibial Interlocking Nail Bolt (All Sizes) (Ao / Sorat / Image) , Expert Tibial Interlocking Nail Ss (All Sizes) (Ao / Sorat / Image) , Expert Tibial Interlocking Nail Bolts Ss (All Sizes) (Ao / Sorat / Image) , High Tibial Osteotomy Plate With Screws Of All Types (All Sizes , With Screws) (Ao / Sorat / Image) , Humerus Nail System (All Sizes) (Steel , All Sizes) (Ao / Sorat / Image) , Schanz Pin (Cortical, Cancellous & Tapering) (Steel , All Sizes) (Ao / Sorat / Image) , Universal Clamps (Steel , All Sizes) (Ao / Sorat / Image) , Universal Tubular Rods, (Steel , All Sizes) (Ao / Sorat / Image) , Universal Rod To Rod Clamps (Steel , All Sizes) (Ao / Sorat / Image) , Universal T Clamp (All Sizes) (Steel, All Sizes) (Ao / Sorat / Image) , Nut (External Fixator, Steel, All Sizes) (Ao / Sorat / Image) , Bolts (External Fixator, Steel, All Sizes) (Ao / Sorat / Image) , Ha Coated Schanz Pin (Steel, All Sizes) (Ao / Sorat / Image) , Arthroplasty Set (Tkr And Thr Set) (Stryker / Johnson Johnson / Zimmer) , Arthroscopy Set (For Knee And Shoulder) (Stryker / Johnson Johnson / Zimmer) , Inj. Bupivaccine 20 Ml , 5-0 Silk Suture For Eye Surgery , 8-0 Vicryl Suture For Eye Surgery , Cartoviejo Calipers For Eye Surgery , Utrata Capsulorlexige Forceps For Eye Surgery , Green Blade , Oxygen (Medicinal Gas) Inhalation , Nitrous Oxide Inhalation , Morphine Injection 10 Mg/Ml, 1 Ml Ampoule , Morphine Tablet 20 Mg , Tramadol Hydrochloride Capsule 100 Mg , Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule , Pethidine Injection 50 Mg/Ml, 1Ml Ampoule , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent , Metronidazole Tablet 200 Mg , Hydroxycobalamin Injection 1 Mg/ Ml , Warfarin (Sodium) Tablet 2 Mg , Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms , Nifedipine Capsule(Sublingual) 5 Mg , Podophylline Resin Topical Solution 25% , 10 Ml Bottle , Furosemide Tablet 20 Mg , Mifepristone Tablet 25 Mg , Misoprostol Tablet 25 Mg , Chlorpromazine (Hydrochloride) Tablet 100 Mg , Fluphenazine Injection 25 Mg, 1 Ml Ampoule , Haloperidol Tablet 5 Mg , Risperidone Injection Long Acting 25 Mg , Olanzapine Injection 405 Mg , Olanzapine Injection 10 Mg , Olanzapine Injection 210 Mg Long Acting , Olanzapine Injection 300 Mg Long Acting , Donepezil Injection 10 Mg , Buprinorphine Tablet 2 Mg , Buprinorphine Tablet 0.4 Mg , Methylphenidate Tablet 5 Mg , Tranylcypromine Tablet 5 Mg , Buprenorphine Transdermal Patch 10 Mcg/Hour , Buprenorphine Transdermal Patch 20 Mcg/Hour , Agomelatine Tablet 25 Mg , Cariprazine Tablet 1.5 Mg , Pyridoxine Tablet 10 Mg , Chloroquine Phosphate Injection 40 Mg/Ml , Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50 Ml Bottle , Quinine Sulphate Tablet 300 Mg , Quinine Dihydrochloride Injection 300 Mg/Ml, 2 Ml Ampoule , Temphos 50% Ec 5 Liter Pack , Malathion Technical 95%, 250 Kg , Deltamethrin 2.5% Wp, 25 Kg , Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) , Pyrethrum Extract 2% , Coupons For Hepatitis C Virus Genotype Testing (Pcr) , Coupons For Hepatitis C Virus Rna Viral Load (Pcr) € Svr , Coupons For Hepatitis Be Antigen Test , Coupons For Hbv Dna Quantitative Test(For Diagnosis Of Hepatits-B) , Molecular Biology Grade Water As Per Requirement , Screw Capped Storage Vial 2Ml (500 Vials) Per Pack 2 Ml , 100 Well Micro Tube Storage Box , Single Channel Variable Volume Micropipette 20-200 Ul , Rnase And Dnase Degradation Solution , Rnase And Dnase Degradation Solution Wipes , Anti Hemophillic Factor Ix Vial Injection Size 500 Iu , Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule , Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole , Deferiprone Tablet 500 Mg , Desferrioxamine Injection 500 Mg , Medroxyprogesterone Acetate Injection Ip (Dmpa ) 25 X 1X 1Ml (Contraceptive Injection For Im Use Only) , Quadruple Blood Bags 450 Ml (Hll) , Quadruple Blood Bag With Sagm 350 Ml (Hll) , Quadruple Blood Bag With Sagm 450 Ml (Hll) , Reagents Bovine Albumin 22% , Dacarbazine Injection 200 Mg, 10Mg/Ml Vial , Dacarbazine Injection 500 Mg , Epirubicin Injection 10 Mg, 2Mg/Ml Vial , Fluorouracil Injection 1 Mg , Gemcitabine Injection 200Mg, 100Mg/Ml Vial , Gemcitabine Injection 1000Mg, 10Mg/Ml Vial , Isophosphamide Injection 200Mg, 100Mg/Ml Vial , Tamoxifen Citrate Tablet 10 Mg , Actinomycin Injection 0.5 Mg , Thalidomide Tablet 100 Mg , Exemestene Tablet 1 Mg , Morphine Tablet 10 Mg , Morphine Tablet 30 Mg Special Repair , Buprinorphine Patch 5 Mg , Buprinorphine Patch 10 Mg , Buprinorphine Patch 15 Mg , Trastuzumab Injection 150 Mg , Trastuzumab Injection 450 Mg , Onco Bcg Injection , Mitomycin Injection 40 Mg , Bortezomib Injection 2 Mg , Ifosfamide Injection 1 Gm , Codon Set , Oxygen Tubing, Suction Tubing (Different Colours) , Grip Lock , Octopus Arc-Biannual Rate Contract Connector (Length 1-10 Cm 1.5*2.5, 2-10 Cm 1.5*2.8)Pur Vol- 0.57 Ml , Q-Way 6 Inches ,Sterlized Using Ethylene Oxide , Transpore 2 , Transpore 4 , Anti Diptheria Serum , Hepatitis B Vaccine (R Dna) I.P. , Urine Screening Through Dry Chemistry Rapid Testing Kit/Strips For Multiple Drug Uses:- 1. Morphine/ Opiates 2. Buprenorphine 3. Tramadol 4. D. Propoxyphene 5. Benzodiazepines Test Kit Kit (Urine Drug Kit) , Nicotine Patches , Tablet Vareniciline 0.5Mg , Tablet Vareniciline 1 Mg , Cbnaat Tb Cartridges - , Early Childhood Development (Ecd) Kit For Ashas - , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 6.5 Cm X 5 Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 15.5 Cm X 8.5Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 25 Cm X 10 Cm , (Pack Of 100) , Coutery Pad (Single Unit) , Chest Tube Drainage With Water Seal Bag No.28 , Chest Tube With Water Seal No.32 , Turp Loop , Craner Wire Splint , Bb Splint (Bohler- Braun) , Bed Side Pulley , Skeletal Traction , 3-0 Mesh For Lap Ingunal Hernia A)Right Side B)Left Side , Partial Absorble (10X6 Cm)Vicryl Mesh For Ipom , Stainless Steel Wire 26 G. Soft Isi/ Iso/Ce/Marked. , Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed , Denture Spirit-Surgical Spirit With Methyl Salicylate, Diethyl Phthalate And Caster Oil Dentured Alchol, 500 Ml Bottle(Covid) , Lox 10 % Spray 50 Ml , Cell Seaker , Right Angle Needle , Sickle Knife , Micro Scissors - Straight , Set For Stapedectomy , Micro Suction Tips Set Of 5 Different Sizes , Wire Speculum / Screw Speculum , Hydro Cannula , Phaco Machine Cassette , Lead Standard 12 Leads , Acquisition Mode (Simultaneous 12 Leads Acquisition) Samplin Rate 100 Hz, Ad Converter 24 Bits , Operation Mode Manual Auto , Rhtym 1 Channel 1 Minute, Memory 1000 Cases , Polarzing Volatage + 300Mv, Noise Leve 15U , Threshold 20Uv, Ac 100-240 V , 50 /60 Hz, Dc 14.4V 2500 Mah, 36.00 Wh , Inupt Mode Floating And Defibriliation Protection ( Ecg Machine) , Dialer , Chopper , Phaco Tip , Rhesis Forceps , Nuclear Express Or Hook , Conjuctival Scissor , Lims Forceps , Inj. Carpinol (Pilocarpine Nitrate Ip 0.5 %Iv) , Blurehex Dye , Needle No. 26 ½ , Phaco ( Tip & Sleeve) Alcon , Phaco Cassettes , Frost , Cement Spatula , Metal Cutting Bur , Composite Syring , Bond Adhesive , X- Ray Lead ( R & L) , Nucleic Acid Extr Silica Bead , Drill Bit 10 , Drill Bit 6 , Lignocaine Spray 10 % 10 Gm , Turp Set (Oblique Topline Telescope 30, Enlarged View, Diameter. 4Mm,Length 30 Cm, Autoclable .) , Chromic Catgut No. 1 Blunt Needle (Liver Suture) , Inj. Laxicard 50 Ml Iv , Inj. Methyldopa , Screw Removed Forceps Plies Type , Self Centering Forceps 12 , Self Centering Forceps 4 , Self Centering Forceps 6 , Semen Diluting Fluid 125 Ml (Nice) , Sensorcaine Injection 0.5% 20 Ml , Limss Forceps , Wire Veetis , Diluent 20000 Ml (Automated Haematology Analyzer) Three Part (Medonic M - Series M32 B Part Iii Cell Counter) That Prepares Blood Samples For Analysis By Creating An Isotonic Environment For Red Blood Cells And Platelets, And Also Helps In Lysing Red Blood Cells. It Is A Crucial Component For Accurate And Reliable Blood Cell Counts And Differentials , Lyse 5000 Ml (Automated Haematology Analyzer) Three Part (Medonic M - Series M32 B Part Iii Cell Counter) That Prepares Blood Samples For Analysis By Creating An Isotonic Environment For Red Blood Cells And Platelets, And Also Helps In Lysing Red Blood Cells. It Is A Crucial Component For Accurate And Reliable Blood Cell Counts And Differentials , Medonic M - Series M 32 B Con - Sol 3 Ml , 21 G 1 Needle (Dispo Van/ Hmd / Bd) , 23 G 1 Needle (Dispo Van/ Hmd / Bd) , Microscopic Cover Glass (English Glass) (Blue Star / Gem -Dx / Boroit) , Blood Bag Tube Sealer With Battery Backup , Sidox Fogging Agent , Lox 5 % Iv Injection , Mesh. Ethico Left Right 15 / 5 , Mesh. Ethico Left Right 7.5/ 5 , Nalbuphin Injection , Butadol Injection , Mercury Pure Triple Distilled (Dpi/Dentsply/Prevest) , Calcium Hydroxide , Paste System Based And Catalyst -Radiopaque (Septodent / Dentsply / Dpi) , Gum Paint (Dr. Reddy / Shofu) , Mini Plates Isi/ Iso/Ce/Marked. , Guide Wire Teflon Coated J Tip , Guide Wire Teflon Coated V Straight Tip , Gum Paint , Flowable Composite , Gates Glidden Drill No. 1 , Gates Glidden Drill No. 2 , Gates Glidden Drill No. 3 , Iopa Film Size 30 Mm X 40 Mm , Iopa Film Size 31 Mm X 41Mm , Air Rotor Spray Bottle , Dental Chair Covering Sterilized Cling Foil Rolls Isi/ Iso/Ce/Marked. , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) , Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution , Sgpt 5X20ml Erba , Crysta Gic , Suction Tip , Burr Cutting (Tungsten Carbide) ( 2Mm, 3 Mm, , 4 Mm, 5 Mm, 6 Mm, 7Mm) , Intralipid 20 % 10 Ml Inj. , Salmonella Kit (Antigen Types (O, H, Ah, Bh), Pack Sizes (E.G., 2+2X5ml, 4X5ml For 100 Tests), Requirement For Positive/Negative Controls, (Widal )Slide/Applicator Sticks, Storage At 2-8°C, Long Shelf Life (18-24 Mo), And Performance Features Like =98% Specificity & Rapid (=3 Min) Results For Slide Tests, Ensuring Reliable Typhoid Diagnosis. ) Arkray , Sodium Hypchloride 5 Ltr 10 % Packing , Magna Pure 24 Total Na Isolation Kit, Pack Size-96(Covid) , Magna Pure 24 Processing Cartridge, Pack Size-48(Covid) , Magna Pure 24 Tip Ptark (Comes With Pierecing Tools)Pack Size-48(Covid) , Magna Pure Tip 1000 Ul, Pack Size-3840(Covid) , Framestrips With Flat Caps High Profile, Pack Size-120(Covid) , Magna Pure Sealing Foil,Pack Size-100(Covid) , Mplct Na Isolation Kit- Lysis/ Binding Buffer Refill, Pack Size-100Ml(Covid) , Framestrip With Flat Caps-Low Profile(Covid) , Magna Pure 96 External Lysis Buffer(Covid) , Light Cycler -480 Multiwell 11 Plate 96(Covid) , Light Cycler 8-Tube Strip Adapter Plate(Covid) , Manual Rna Extraction Kit-50 Test(Covid) (Mylab / Altona) , Tocilizumab Injection 400 Mg/20 Ml(Covid) , Lc Prep Lysi/Bind Buff Dna,Mbp , Dexamethasone 6 Mg Tablet(Covid) 6 Mg , Coronil Kit Coronil Kit Each Contains(80Tab+80Tab+20Ml) , Tocilizumab 80 Mg , Sars-Cov-2 Sequencing Kits Test Kit Kit , Corbevax Vaccine,10 Ml Vial , Direct Ldl 1X30/1X10ml Erba , Ppt 10Tu Arkray / Beacon , Absolute Alchol 99.95 % 5 Lt , Coupling Jar Glass , Coupling Jar Plastic , Esr Tube (Western Gren) Disposable , Thermal Paper For Bio Analyzer 1 X 1 , Slide Tray , Pti Uniplastin Quantitive Kit , Anti Ab 10 Ml , Reagent Bovine Albumin 22 % , Anti D Igg + Igm , Cover Sample Size (0.5-1.5 ?L), Measurement Range (E.G., 20-800 Mg/Dl), Testing Time (5-10 Seconds), Enzyme Type (Glucose Oxidase Or Fad-Gdh), Hematocrit Range, And Compatibility With Specific Glucometers . Key Features Include No-Coding Technology, Single-Use Design, And Storage Requirements (Vial, Cool, Dry Placeglucostrip (300 Strips With Meter) (Sensacore) , Racked Filter Pipette Tips (Sterile) 20 Ul , Racked Filter Pipette Tips (Sterile) 100 Ul , Racked Filter Pipette Tips (Sterile) 200 Ul , Racked Filter Pipette Tips (Sterile) 1000 Ul , Filter Pipette Tips (Sterile) 200 Ul , Filter Pipette Tips (Sterile) 1000 Ul , Sensitivity Discs (Pbl /Himedia) , Ethanol 500 Ml , Dropper Plastic (Abdos/Tarson) 3 Ml , Glass Slide (1 * 100) Blue Star , Cmark , Crp One Test (Arkray/ Aggape/ Tulip) , Glycine 3 Ltr , Inoculating Loop 10 Mm With Holder , Zn Stain , Stragiht Wire With Holder , Cedar Wood Oil , Ph Meter , Sterile Swab Sticks , Spirit Lamp With Gas Cylinder , Glass Rods , Discarding Jar Plastic , H2o2 Reagent , Koh Reagent , Oxidase Strips , Pepton Water , Sterile Swab , Catalase Reagents , Anti Sensitivity Drugs Vancomycin , Anti Sensitivity Drugs Azitrhomycin , Anti Sensitivity Drugs Levlofloxacin , Anti Sensitivity Drugs Doxycylline , Anti Sensitivity Drugs Cefoxitin , Anti Sensitivity Drugs Amoxiclav , Anti Sensitivity Drugs Meropenum , Anti Sensitivity Drugs Pipertazobactum , Anti Sensitivity Drugs Aztreonam , Anti Sensitivity Drugs Gentamycin , Anti Sensitivity Drugs Ceftrixone , Anti Sensitivity Drugs Ceftazidime , Anti Sensitivity Clindamycin Pencillin , Anti Sensitivity Ampicillin , Anti Sensitivity Imiperum , Crp Latex 100 Test , Rf Latex 100 Test , (Copper Condenser, Anti-Rust Coating, Anti-Freeze Thermostat, White, ) 5 Years Comprehensive Warranty , Energy Rating: 3 Star. Annual Energy Consumption: 1464.72, 3 Star Window Ac 2 Ton , Gold Fin+ - Increase Durability, Ocean Black Protection, Ez Clean Filter; Low Gas Detection; 100% Copper Condenser; Hi Grooved Copper; Smart Diagnosis System; Comfort Air; Monsoon Comfort; Self Diagnosis; Auto Clean; On/Off Timer; Sleep Mode; Diet Mode Plus; Fan Speed Steps: 6 1.5 Ton 3 Star Window Ac , Hospimax Automated Blood Coagulation Analyzer - Pt Kit 280 Test (With Washer , Reagent R1, Roter, Cleaner & Control) , Hospimax Automated Blood Coagulation Analyzer - Aptt Kit 720 Test (With Washer , Reagent R1 , Roter, Cleaner & Control) , Hiv Protection Kit , Acetic Acid 99.9 % Pure 500 Ml Bottel , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria , Forceps Big , Forceps Small , One Strip Dengue Combo Test (Ns1 Igg Ogm) , One Strip Hiv-Hcv-Hbsag Combo Test , Hiv 1+2 And Syphillis Combo Test , Troponin T Test , Chikungunya Antibody Test , Elisa Plate Reader (Erba) , Elisa Plate Reader With Led (Athenese/ Meril) , Elisa Plate Washer (Erba) , Elisa Plate Washer (Athenese / Meril) , Urine Strip Analyzer , Hav (Elisa Kit) , Hev (Elisa Kit) , Leptospirosis (Elisa Kit) , Scrub Typhus Elisa Kit , Rcm Media (Ready To Use) , Agar / Agar Media (Ready To Use) , Test Tube Rack (Aluminium) , Slide Tray (Aluminum) , Nichrome Wire Loop , Grams Stain (Ready To Use) , Laboratory Forceps , Micirocentrifuge Tube Sterile 1.5 Ml , Sodium Hydroxide Pallets 500 Gm , Trisodium Citrate 500 Gm , Pottasium Dihydrogen Orthophosphate 500 Gm , Sodium Phosphate Monobasic Dehydrate 500 Gm , Pcr Tubes (0.2 Ml) , Laboratory Tempreature Meter , 5-0 Polypropylene
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
18.
Defence #8763782 Technical Bid
Job Order Repair Of Vehicle Tata Mobile Vehicle Ba No 12C 094690P ( 207 Di ) , Repair Of Vehicle Tata Mobile Ba No 12C 094690P ( 207 Di ) Job Order For Opening Removing , Dismanting The Defected Unserviceable / Non Functional Items / Spares From The Existing Vehicle . Segregating The Servicable And Unservicable Spares Parts With The Held Of Manpower At Site As Required . Repairing Of Repairable Spares And Replacement Unsv Spares Also Refitting Including Cleaning , Greasing And Oiling Etc . To This Effect Testing Will Bew Carried Out Unit The Satsfaction Of The Users I . E . Oic Mt / Me . All New Spares / Items Must Be In Proper Size , Make Model Etc As Per The Existing Items / Spares Of The Above Said Vehicle . Water Pump-01 , Gasket For Water Pump-01 , Glow Plug-03 , Overhauling Engine Kit-01 , Gasket Cly Head Cover-01 , Timing Belt-01 , Gasket Cat Converter , Gear Crank Shaft -01 , Oil Seal-01 , M Seal-01 , M Seal-01 , Threebond-02 , Clutch Realese Fork-01 , Rubber Hose-01 , Hose Clamp-01 , Oil 15W40-7500Ml , Air Filter-01 , Filter Element-01 , Hose-01 , Plug-01 , Cap Radiator-01 , Clamp-01 , Brake Fluid-100Ml , Coolant 1Ltr-02 , Rust Off-01 , Bulb Holder-01 , Black Tape-01 , Oil Filter-02 , Seal Kit-02 , Rt Suspension Kit 32 Dia Ar Bar-01 , Offer Drg Assy-02 , Head Lamp Assy Lh-02 , Brake Pad Safari Antisqueal-02 Note : All Unservicale Spares / Items Are The Contractors Property , Necessary Credit May Be Given By The Vendor At The Time Of Quoting Rates .
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
West Bengal View Result →
19.
Railways #8670675 AOC
Supply Of Rust Converter Confirming To Is 13515-1992 (Reaffirmed Year 2023), It Should Be In Single Pack System Of Organic Base. The Solvent Base Should Be A Blend Of Liquid Isocyanate Per-Polymer With Reducing Agent. Note:- (I) Supply Should Accompany The Batchs Work Test Certificate For The Quality Of Goods In Conformity To Specified Standards Along With The Supply. (Ii) Guarantee / Warranty Period: - 30 Months From The Date Of Supply & The Supply Should Accompany With Guarantee / Warranty Certificate. (Iii) Material Safety Data Sheet (Msds) For The Material To Be Provided Along With The Supply. (Iv)Date Of Supply Shall Not Be More Than Two Months From The Date Of Manufacture. (V) Packing Should Be Of 5/10/20 Ltrs In Cans.Rust Converter Confirming To Is 13515-1992 (Reaffirmed Year 2023), It Should Be In Single Pack System Of Organic Base. The Solvent Base Should Be A Blend Of Liquid Isocyanate Per-Polymer With Reducing Agent. Note:- (I) Supply Should Accompany The Batchs Work Test Certificate For The Quality Of Goods In Conformity To Specified Standards Along With The Supply. (Ii) Guarantee / Warranty Period: - 30 Months From The Date Of Supply & The Supply Should Accompany With Guarantee / Warranty Certificate. (Iii) Material Safety Data Sheet (Msds) For The Material To Be Provided Along With The Supply. (Iv)Date Of Supply Shall Not Be More Than Two Months From The Date Of Manufacture. (V) Packing Should Be Of 5/10/20 Ltrs In Cans.,Rust Converter Confirming To Is 13515-1992 (Reaffirmed Year 2023), It Should Be In Single Pa Ck System Of Organic Base. The Solvent Base Should Be A Blend Of Liquid Isocyanate Per-Polymer With Reduci Ng Agent. Note:- (I) Supply Should Accompany The Batchs Work Test Certificate For The Quality Of Goods In Co Nformity To Specified Standards Along With The Supply. (Ii) Guarantee / Warranty Period: - 30 Months From Th E Date Of Supply & The Supply Should Accompany With Guarantee / Warranty Certificate. (Iii) Material Safety Data Sheet (Msd
Contract Date: Jan 29, 2026 Contract Value : 18,690
Government Departments No of Bidders 1
20.
Railways #8659992 AOC
Supply Of Procurement Of Universal Fail Safeprocurement Of Universal Fail Safe,Supply Of Electronics For Universal Fail Safe Block Interface As Per Irs Specification No. I Rs:S-104/2012 Ver.O ( Latest Amendment ) Suitable For Deltron Make Ufsbi Along With Installation & C Ommissioning Of Ufsbi Systems Along With Its Accessories. Supply Of Pre- Wired Powder Coated Ms Cab Inet At Least 36U(1.6M) Approx For Housing Ufsbi Electronic Modules, Relay Racks, Spd Modules, 4 Nos Of Qn1 (8F/8B) Relays Per Pair, Etc. As Required For Commissioning Of Ufsbi Electronics In Automatic Bl Ock Signalling Application Suitable For Deltron Make Ufsbi. Supply Of Rs232 To Fiber Converter For Oper Ating Ufsbi Equipment As Per Irs Specification. No.Irs:-S-104/2012 Ver.0 On Dark Fiber Suitable For De Ltron Make Ufsbi. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] , Supply Installation, Wiring, Testing & Commissioning Of Dual Redundant Arrangement Of Ufsbi Electronics For Exchange Of Vital Relay State Information Between Two Different Signaling Installa Tions Pertaining To Abs Ib Signalling Application Working On Ofc/Quad Media In Set And Consisting Of F Ollowing Sub Systems A) Electronics For Ufsbi Interface In Redundancy As Per Irs Spec At The Irs S-104 /2012 See 0 (Latest Amendment) Qty. Two Nos. Modem For Ufsbi (For Use Of Secondary Media Ofc /Qu Ad) Qty. Two Nos. C) Automatic Media Changeover Of Modem Working On Redundant Channels For Data Transmission On Ofc/Quad Qty. Two Nos. D) Pre Wired 36-U Floor Mounter Ms Cabinet Suited To Fit Tw O Sets Of Ufsbi Electronics With Siemens Grey/Smoke Grey Powder Coating (Rust Proof And Long Life), Ti Ned 3-4 Mm Thick Tined Acrylic / Polycarbonate /Glass Sheet Fitted On Front Door And Metal Back Door, With Double Lock And Bottom Cable Entry Facility Qty. One No. Item (A) Shall Be Inspected By Rdso And Item (B), (C) & (D) By Change Ufsbi Rk On Be Consignee Along With Oem Test Report Note 1 Pair Shall Co Nsist Of 2 Sets Of Above Mentioned Items. [ Warranty Period: 30 Months After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Page 1 Of 9 Run Date/Time: 29/09/2025 12:02:38Stores/Northern Rly Tender Document , Universal Fail Safe Block Interface ( As Per Rdso Spec. No. Irs-S-104/2012 Ver. 0 With La Test Amendments ) Suitable To Work On Ofc/1 Quad Cable As 16 Input & 16 Output. Multiplexer For Ib Sig Nalling Including 68 No.S Of Qn1 (8F/8B) Relays For System Commissioning [ Warranty Period: 30 Mont Hs After The Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ]
Contract Date: Jan 27, 2026 Contract Value : 79.34 Lakh
Government Departments No of Bidders 1
Uttar Pradesh View Result →
21.
Defence #8647848 AOC
Tender For Repairs Maintenance Of Periodical Services To Overhead Tanks Under Ge(W) Jrc; 2 Surface preparation: Empty the water from water tank Removal of old existing plaster of wall and floor from inside of water Tanks and disposal of unserviceable rubbish out site the campus as per direction of the Engineer Incharge with in 3 km. Cleaning of surface of loose dust and dirt cement slurry etc. by means of wire brush, dust removing brush and scraper etc. In case of Pot Holes /Cracks same shall be repaired with cement putty admixed with Multi Purpose Polymer as per manufacturer instructions etc. (Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 3 Gola on Mother Slab:Providing and Making of PCC coving (gola) of size 75 mm x 75 mm with concrete Mix (1:2:4), cement, sand, grit and including cost of mixing water proofing compound of approved make etc. complete as per direction by Engineer In Charge (Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 4 Waterproofing coat : Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent , having 80 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 5 Providing and sealing all pipe insertions in wall and floor with epoxy mortar by making covong arround pipe.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 6 Horizontal & Protection & Slope : layingslope making and protection to the waterproofing treatment with 30 mm avg. thick M20 grade screed for floors, including admixed with PC based integral waterproofing compound SmartCare Vitalia, etc. complete, as per manufacturers specifications(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 7 Vertical wall & Protection : Providing and applying 20-25 mm thick with CM 1:4for wallplasteringadmixed with PC based integral waterproofing compound SmartCare Vitalia, etc. complete, as per manufacturers specifications (Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent). 8 Anti Bactirial Protective Coat for Potable Water tank - over plastered surface : Supplying and applyingtwo coats of SmartCare Epoxy TriBlock to pre-dampened plastered surface @ 2.60 sqm/kg. Coating shall be certified by CFTRI as per 21CFR-175-300 of USFDA, with adhession strength 3 MPa as per ASTM D 4541:02. The coating shall be able to withstand positive hydrostatic pressure of 4 bars as per DIN 1048.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 9 Removal of damaged Concrete-surface Preparation: Removal of existing affected, distressed, loose cover concrete including loose damaged concrete from all structural members up to beyond the corroded steel reinforcements to a depth of 10 mm minimum behind the reinforcement only at affected concrete (Good & sound concrete should not be chipped / damaged) by chipping / hacking with chisel and hammer or by mechanical means like light weight chisel hammer, chippers, making saw cut at periphery to avoid feather edge including replace the damaged reinforcement by welding as per existing dia of bar and removal and disposal of debris at plant area including labour, tools, electricity, plant and machineries etc. complete as directed by Engg.in charge. Depth of chipping may vary from 20 to 100 mm.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 10 Rust Treatment of exposed rebars using APCOREP RUSTREM : Providing & applying Alkaline Rust converting primer APCOREP RUSTREM in two coats conforming to IS-13515 to exposed existing rebars after removing & cleaning loose rust by wire brush and leave it for 6-8 hours. The rust converter shall have a minimum pH of 7.5 and shall be able to convert both hematite and magnetite forms of rust and shall pass 400 alternate immersion cycles in 3.5 % NaCl as per ASTM G 31.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 11 Corrosion protection of exposed rebars using APCOREP RUSTCOAT RB : Providing and applying anti-corrosive coating APCOREP RUSTCOAT RB (CSIR/CBRI know how) in 2 coats with time interval of minimum 12 hours.The coating shall have same coefficient of thermal expansion as that of concrete with bond strength of more than 2.5 MPa both with steel and concrete.This coating shall be applied over APCOREP RUSTREM coated rebars(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 12 Corrosion protection of unexposed rebars using APCOREP CPCI Coating on concrete : Providing and applyingconcrete penetrating, migratory bipolar corrosion inhibitor APCOREP CONPROTECK CPCI by brush/spray with dosage of 4Sqm/ ltr, over the entire chipped off / exposed concrete area including material, equipment, labour etc. complete in order to arrest further corrosion of reinforcement bars. The application of APCOREP CONPROTECK CPCI shall shift corrosion potential by minimum 100 mV wrt control and shall reduce corrosion current by 60% wrt control by accelerated corrosion test (Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 13 Providing & applying a bond coat of Epoxy Bonding Agent based chemical on the entire surface before the application of Apcorep RM - Polymer modified mortar when the the bonding surface is tacky.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 14 Application of Polymer modified mortar/Smart Care Repair mortar - Providing and applying single component, dual shrinkage compensated, high strength , fibre reinforced thixotropiccementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1 Day and 45 Mpa at 28 days and capable of applying upto 50 mm thick in single layer such as APCOREP Repair mortar of Asian Paints or equivalent, to the prepared concrete area for thickness up to 50 mm, after applying cement based bonding coat as per detail specification , befored the epoxy bonding agent becomes tack free initially by hand and finally finishing the same with trowel carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface where the thickness of application is less than 50 mm in patches as per specification . Item rate is inclusive of all material labour tool , plant , machineries curing etc. complete and as directed by Engineer in charge . Payment to be made in sq. meter for thickness up to 50 mm of PMM for patch area repaired.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 15 Polymer modifiedHi- Flow Smartcare Microconcrete (For repair thickness more than 50 mm & Up to 70 mm):- Providing and laying special repair material micro-concrete for reinstatement of members having thickness of repair more than 50 mm and jacketing using single component, high strength, high flow cementitious microconcrete having compressive strength minimum of M40 at 28 days such as smartcare Microconcrete LH, blended with washed SSD , graded low absorption high density aggregate of size 3mm to 10 mm at 50 % by weight of microconcrete (if thickness is 100 mm or more) and water as per data sheet and pouring into the shuttering if required than birds peak type form work using suitable arrangement or if required using pumping device for uniform flow of microconcrete. The side shuttering can be removed after minimum of 24 Hours, preferably 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate at all heights, including all material, labour, tools, plants and machineries, curing etc. complete as directed by Engineer in charge (Payment shall be made in square meter for thickness up to 100 mm of microconcrete of area repaired including shuttering). 16 Material and labor for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism)having RPM not less than 1500, sandingpad of 80 Grit having dia of 7/9to make thesurface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/chajjas to be done with repair mortar to get even surfaces incl preparation of old sufaces of wall/ceiling by filling cracks by berger bison putty/crack filler of approved brand and make good smoothen surface by sand paper and applying two coat of premium acrylic smooth exterior emulsion paint of approved colour with silicon additive & color stay technology, Excellent dirt pick up resistance of Berger paint Ltd or equivalent of other approved make low VOC less than 50gm/ltr as per the LEEDS specification, Anti Algal Properties in two coats @ 1.79 Ltr(Undiluted)/10 sq mtrs diluted with water as per manufacturer instruction applied over one coat of acrylic waterbased exterior grade primer @ 0.90ltr (undiluted)/10SQM diluted with water in 1:1 ratio as per manufacturer instruction and all coats including primer to be applied with fully automatic airless spray machineof paint application with a flow speed of min 1 ltr per minutehaving a pressureof3300PSI all as specified and directed.Allow 6-8 hrs todry the surface in subsequent of paints and incl necessary scaffolding at any height complete all as specified and as directed by Engineer-in-Charge.(Product make : Berger/Asian/Dr Fixit/Sika/Fosroc or equivalent) 17 M&L for rewriting/repainting to existing writing letters or figures not exc 30 cm height in block Roman, Italian or Indian letters including stops, comma, arrows, brackets, dashes etc on sign board (Black or yellow base) including two coats of oil paint over a coat white base synthetic enamel paint, all as directed.
Contract Date: Jan 09, 2026 Contract Value : 45.43 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
23.
Civil Aviation #8553625 AOC
Tender For Construction Of Apron And Taxiway At Kishangarh Airport. Sh Electrical Work.; 1 Supply of Medium Intensity Elevated type omni directional LEDTaxiway edge Light fitting (LED type) for aviation visual aids requirements complete with LEDs, optic lens, power converter,two pin secondary lead, central column assembly, breakable coupling, base plate, gaskets, bolts etc. and all other standard accessories required as per ICAO and conforming to technical specifications. 2 Supply of omni directional Inset Type Taxi way edge Light Fitting complete with shallow base, matching body made of die cast aluminium, pr-focused LED lamp and driver units suitable to work on 15 w 6.6/6.6 amps Isolating transformer with all accessories confirming to ICAO requirement complete as required. 3 Supplyof following type Bi-directional inset type High intensity Runway Edge light fitting for aviation visual aids requirements complete with shallow base of side cable entry, matching body of the fitting complete with 2 x 105 Watts, 6.6 amps pre-focused reflector halogen lamp connected heat resistant accessories, prism assembly, optical assembly, O ring seal, pressure relief test plug, hardware, Cover Gas Kit and all other standard accessories required as per ICAO and conforming to technical specifications. 4 Clear/Clear 5 Clear/Yellow 6 Supply of Single core, 06 Sqmm, 5 KV,XLPE insulated & PVC seathed stranded copper conductor, antitermite & antirodent Airport lighting cable confirming to IS 7098 (Part-II) with up to date ammendement and as per technical specifications. 7 Supply of Single core, 16 Sqmm, 5 KV,XLPE insulated & PVC seathed stranded copper conductor, antitermite & antirodent,Airport lighting cable confirming to IS 7098 (Part-II) with up to date ammendement and as per technical specifications. 8 Supply of 2 core 4 sqmm 600 V grade, copper conductor, EPR insulated, PCP sheathed, underground secondary cable complete as specified complete as required and conforming to technical specifications. 9 Supply of following type, 5 KV grade, 50 Hz, series Isolating Transformer encapsulated in polyester resin, finally moulded in neoprene type rubber with primary and secondary connectors etc and all other standard accessories required as per ICAO and conforming to technical specifications. 10 15 W, 6.6/6.6 Amps. 11 45 W, 6.6/6.6 Amps. 12 100 W, 6.6/6.6 Amps. 13 200 W, 6.6/6.6 Amps. 14 Supply of 5 KV grade plug & receptacle (Essna Connector) of type I class B connector & suitable for field attachment with5 KV grade PVC insulated and PVC sheathed single core 6 sqmm copper conductor cable as etc complete as required and conforming to technical specifications. 15 Supply of 5 KV grade plug & receptacle (Essna Connector) of type I class B connector & suitable for field attachment with5 KV grade PVC insulated and PVC sheathed single core 16 sqmm copper conductor cable as etc complete as required and conforming to technical specifications. 16 Supply of 1.1 KV grade plug & receptacle (Essena Connector) of type II class B connector & suitable for field attachment with1.1 KV grade PVC insulated and PVC sheathed 2 core 4 sqmm copper conductor cable etc complete as required and conforming to technical specifications. 17 Supply, installation, testing and commissioning offollowing ratingIndoor type air cooled constant current regulator of microprocessor controlled, thyristor type suitable for operation on 230 Volts + 10%, 50 Hz input AC supply with 5 steps variation of current output, suitable for local and remote control operation with suitable control supply and able to communicate with PC or PLC controlled system, withoutput current indicated on multifunction digital display, overcurrent, over voltage, open circuit and earth fault protection and earthleakage meter, positive back indication equipments, hours run counter,complete as required, confirming to ICAO requirements and as per technical specifications. 18 4.0 KW 19 7.5 KW 20 Design, Manufacturing, Supply, installation, connection, testing and commissioning of illuminated taxiway/ runway guidance signages of various sizes made of anodized 2 mm (nominal) thick extruded aluminum profile frame with suitable stiffening supports for structural rigidity, 1.5 mm thick aluminum back cover, 4 mm thick poly carbonate sheet with glare free face, supporting legs, breakable coupling etc. The letters and symbols shall be internally pasted/ screen printed with required coloring. The sign boards shall be uniformly internally illuminated with required number of LEDs strips to achieve required illumination level, alongwith drivers, internal control circuit, automatic changeover to function on both main & standby (runway/ taxiway) circuits etcand shall operate without any flickering when operated on input source of 2.8 Amps. to 6.6 amps. series current. The suitable arrangement shall be made for water tightness and locking arrangement. The signages shall be installed on 1:2:4 grade cement concrete of size 400x400x500 mm for each leg and total base of 150 mm thick for the distance of 1.5 mtr. all around the board including installation of isolating transformer, crimping/ jointing of plug & receptacles, laying of secondary leads, connections, earthing etc. complete as required. The taxiway guidance signages shall be as per ICAO and confirming to technical specifications. (legends shall be as approved by Engineer‐in‐charge). 21 Design, Manufacturing and Supply of illuminated taxiway/ runway guidance signages of various sizes made of anodized 2 mm (nominal) thick extruded aluminum profile frame with suitable stiffening supports for structural rigidity, 1.5 mm thick aluminum back cover, 4 mm thick poly carbonate sheet with glare free face, supporting legs, breakable coupling etc. The letters and symbols shall be internally pasted/ screen printed with required coloring. The sign boards shall be uniformly internally illuminated with required number of LEDs strips to achieve required illumination level, alongwith drivers, internal control circuit, automatic changeover to function on both main & standby (runway/ taxiway) circuits etcand shall operate without any flickering when operated on input source of 2.8 Amps. to 6.6 amps. series current. The suitable arrangement shall be made for water tightness and locking arrangement. The taxiway/runway guidance signages shall be as per latestICAO guidlines and confirming to technical specifications. (legends shall be as approved by Engineer‐in‐charge). 22 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID 51mm nominal) 23 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal) 24 Supply of cast iron isolating Transformer housing box, water tight round type, metal container of outside size 330 mm dia, height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick , cast iron moulding suitable to receive a light fitting base plate/ cover plate on the top and underground for housing transformer, power cable and having one/two/ three nos holes as per site requirement on the periphery centre, 75 mm above bottom surface suitable to receive of 50 mm and 15mm dia GI/DWC HDPE/HDPE pipe as required. The box should have two SS earth bolts of M10x40 mm tapped inside near the hole (4 away from the hole centre) and having drain hole at the bottom suitably tapped to receive 15mm dia GI pipe and having clear opening of 220 mm at the top surface and 06 Nos. M10 tapped hole having centre to centre distance of 260mm to receive fittings/base plate and bolts, etc complete as required. 25 Installation of transformer housing boxes with a base concrete of 1:3:6 of size 630x630x100mm thick, all round concrete of 1:2:4, 150mm thick top sloped with 1:2:4 cement including providing and fixing 300mm long 15mm dia B class GI pipe with check nut for drainage of water including excavation of soil and refilling, adjustment of CI boxes etc. complete as required. 26 Installation, testing and commissioning of medium intensity LED type taxiway edge light fitting on the existing transformer housing box including installation of isolating transformer, crimping/jointing of plug & receptacles, layingofsecondaryleads, connections, earthing etc. complete as required andincludes supplyofallmaterials excluding fixture, secondary lead, isolating transformer and plug & receptacles. 27 Installation, testing and commissioning of inset type runway/ taxiway edge light by core cutting in therunway/taxiway/apron pavement, fixing the shallow base with dobefil and hardener, installation of isolating transformer, crimping/jointing of plug & receptacles, layingofsecondaryleads, connections, earthing etc. complete as required andincludes supplyofallmaterials excluding fixture, secondary lead, isolating transformer and plug & receptacles. 28 Laying one number 5 KV grade Airfield lighting cable of sizesingle core6 / 16 Sqmm, 2x4 Sqmm secondary cablein the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. 29 Laying of one number 5 KV grade Airfield lighting cable of size single core 6/16 Sqmmand 2x4 Sqmm secondary leadin the existing masonry duct as required. 30 Excavation of the trench in the hard rock not exceeding 1.5 metres in width, and lift upto 1.5 meters, including getting out the excavated soil and disposal of excavated soil as directed with in a lead of 50 mtrs. 31 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 32 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 33 Providing and fixing 6 SWG dia G.I. wire on surface or in the existing / DWC/HDPE/ metal pipe for loop earthing along withcable etc complete as required. 34 Kerfs cutting with machine in taxiway/runway of PQC/bituminous surface of suitable depth and width for 1 or 2 nos secondary lead along with earth cables and laying of secondary lead and earth cable by wrappingtape i/c refilling the same by suitable sealing materialetc. complete as required and as per instruction of EIC. 35 Upgradation and integration of existing Electro System make Airifeld lighting control and monitoring system (ALCMS) for newly added taxi-C lighting facilities including taxiway edge lights, guard lights, Signages etc complete with all required upgradation/enhancement of software and hardware for the units installed in ATC and CCR hall meeting ICAO/FAA. 36 Supply of FAA certified / compliant model, Elevated, Uni-directional, Yellow, suitable for ICAOall weather operation, LED Runway Guard lights complete with Two elevated LED light fittings, driver, site programmable flash control unit ( switching device), cable lead with plug, Lense, glass, optical assembly, seal, hardware and all standard accessories, ready for site installation along with breakable coupling and base plate as per site requirement etc. compatible to existing ALCMS conforming to latest ICAO / CAR requirement as per specifications complete as required. 37 Installation, testing & commissioning of elevated type Runway guard light fittings i/c installation of isolating transformer, crimping/jointing of plug & receptacles,makingconnectionsi/csupplyofallmaterials excluding fixture, plug & receptacles & isolating transformer etc. as required. 38 Dismantling of existing taxiway lights and shifted to electrical store as per direction of EIC. 39 Design, SITC of 20 Mtr High mast , GI Polygon continuously tapered in three sections suitable for wind speed as per applicable IS 875 Parts- 3, with raising lowering system comprising , head frame, luminaries carriage suitable to install min 10 luminaries in Asymmetrical arrangement as per lighting Design, double drum winch, 6mm diameter SS wire rope , trailing Cu. cable suitable current carrying capacity between top carriage and the base terminal (inside mast) including supplying & laying of required length of 1.1 KV grade of suitable size XLPE insulated PVC sheathed armoured Aluminium conductor power cable between Feeder Pillar of High Mast and Base Terminal in DWC HDPE pipe of suitable size alongwith supplying & making end termination with heavy duty Brass compression gland , with connector, intergal power tool motor, manual handle ,lightning Arrestor , junction box ,weather proof and vandal resistant door flush with the exterior surface containing a terminal plate thick backlite sheet with 32 Amp heavy duty connector for loop in loop out cable terminations. including of followings.... 40 Supply & fixing of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plate and common template. 41 Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and other accessories. 42 Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all other accessories.. 43 Supply & fixing of LED type single dome aviation obstruction light.-02 Nos 44 ITC of minimum 10 nos LED luminaries. 45 Supply of outdoor stand mounted feeder pillar, Installation of the feeder pillar by grouting the stand in concrete, dust and vermin proof with 2 Nos. (1No for Incoming supply and 1 No for spare) 32A TPN MCB incomer including necessary arrangement for auto/mannual and remote control/operation, single dial time switch, 22A TP contactor for the automatic switching of luminaries, power tool control with suitable contactors and raise and lower push button, terminals for incomer 35 sqmm and outgoing 16 & 2.5 sq.mm -01 set etc. complete as required. 46 Dismantling of existing 20 Mtr Highmast and shifting at new location or storein Airport as per instruction of EIC, with the help of suitable tools and plants. 47 Installation, Testing & Commissioning of existing old highmast of 20 Mtr height at new location in the airport as per instruction of EIC etc. complete as required including of followings....(i) Erection of the high mast with the help of suitable tools and Machinery. (ii)Installation of luminaries carriage andluminaries i/c connections.(iii) Installation of existng feeder pillar by grouting the stand in 1:2:4 concrete up to the depth of 100mm and up to 0.5 mtrall around the panel. -01 set 48 Design, Fabricarication, Supply, installation, testing and commissioning of vermin proof, dust proof, front operated, cubicle type, floor mounted, extendable on both sides, outdoor LT panel made out of 2 mm thick CRCA sheet duly rust inhibited, stove enameled, powder coated paint, fully compartmentalized complete with double hinged front door with lockable arrangement etc. including necessary iron channel stand, control wiring, with mechanical interlocking, etc. and having following accessories.INCOMER2 Nos. 400A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Each Incomer shall have one set of the following items:Digital Multifunction Meter, suitable for measure Volatge, Current, Energy, frequency, power factor etc.withCT ratio programmable and auto ranging along with suitable range CTs.1 Set of Indication Lamps, LED type, R,Y,Band MCCB ON, and OFF lamps with protection MCBs.BUS COUPLER1 Nos. 400A 4P MCCB(Ics=Icu=36 KA) with rotary operating mechanismincluding terminal extension.Bus coupler shall have indication ON, and OFF lamps with protection MCBs.BUS BAR1 Set of 600A TPN Busbars of aluminium alloy.OUTGOING02 Nos. 125 A FP MCCB (Ics=Icu=25 KA) with thermal magnetic release.06 Nos. 63 A FP MCCB (Ics=Icu=25 KA) with thermal magnetic release.02 Nos. 32 A FP MCCB (Ics=Icu=25 KA) with thermal magnetic release.10 Sets (1 Set for each outgoing) LED type ON and OFF Indication Lamps with protection MCBs.10 Sets of Rotary operating mechanismincluding terminal extension for all the MCCBs. 49 Desing, Supplying, installation, testing and commissioning ofsection of existing LT Panel section suitable for 04 nos outgoing415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in cubical type compartmentalized CRCA sheet steel of 2 mm thick for frame work and3 mm thick for gland plated i/c. cleaning and finishing complete withpowder coating in approved shade, having 800 Amp. capacity extensible type 4- pole Aluminium alloy bus-bars (approx length-3 mtr) of high conductivity, DMC/SMC bus bar supports with suitable short circuit withstand capacity., bottom base channel of MS section of size not less than 75mm X 40mm X 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 50 mmx5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Alu. busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half i/c. providing following switchgears :-OUTGOING2 Nos. 63 A FP MCCB (Ics=Icu=30 KA) with thermal magnetic release.2 Nos. 40 A FP MCCB (Ics=Icu=30KA) with thermal magnetic release.4 Sets ( Set of 02 for each outgoing) LED type ON & OFF Indication Lamps with protection MCBs.4 Sets (set of 03 for each outgoing) LED type R,Y,B Indication Lamps with protection MCBs.Digital Multifunction meter with RS 485 port -01 no. for each outgoing.CT of suitable ratio -01Set of 03 CTs for each outgoing.4 Sets of terminal spreader for 63 A & 40 AFP MCCBs. 50 Supply of 1100 V Flexible,following Cable with bright annealed bare copper conductor,FR PVC Insulated & PVC Sheathed round Wires as per IS-694 up to date ammended. 51 10 core 2.5 Sqmm 52 4 core 2.5 Sqmm 53 Laying one number 1.1 KV grade highmast control cable of size up to 10 core2.5 Sqmm.in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. 54 Supply of 500W, LED flood light with high pressure die cast Aluminium / standard alloy Housing and LEDs of approved make pasted on diecast housing and high efficiency diffuser, Driver installed on cast luminium housing and prewired upto the terminal block. It shall have luminaire efficacy of not less than 110 lm/W with constant current driver output,Operating voltage range 240V, 50Hz AC supply,CRI>70, CCT from 5700K - 6500K with PF≥0.95 andTHD<10% & surge protection of ≥10KV suitable for outdoor applications.The luminaire shall be minimum IP-66 protected, with 05 year warrenty from OEM etc. complete as required. 55 Supply of 400W, LED flood light with high pressure die cast Aluminium / standard alloy Housing and LEDs of approved make pasted on diecast housing and high efficiency diffuser, Driver installed on cast luminium housing and prewired upto the terminal block. It shall have luminaire efficacy of not less than 110 lm/W with constant current driver output,Operating voltage range 240V, 50Hz AC supply,CRI>70, CCT from 5700K - 6500K with PF≥0.95 andTHD<10% & surge protection of ≥10KV suitable for outdoor applications.The luminaire shall be minimum IP-66 protected, with 05 year warrenty from OEM etc. complete as required. 56 Supply of following size 1.1 kv grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required. 57 4 Cx50 Sqmm 58 4 Cx25 Sqmm 59 Supply of 3.5C x 150 Sq.mm size 1.1 kv grade, XLPE insulated and PVC sheathed, FRLS at outer sheath, Aluminium conductor armoured power cable conforming to IS: 7098(Part-1) 1988 with up to date amendments etc. complete as required. 60 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5 Core x 150 Sq.mmsize cable in the existing RCC/ HUME/ STONEWARE/ METAL/ HDPE/DWC pipe as required. 61 Laying of one number PVC insulated and PVC sheathed/ XLPE 4 core aluminium conductor cable of 1.1 KV grade of size above 35 Sqmm and up to95 Sq. mm in the existing RCC/HUME/METAL/HDPE Pipe as required. 62 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size up to 35 sq. mm in the existing RCC/ HUME/ METAL/HDPE/DWC pipe as required. 63 Supplying and making end termination with suitable size 4 pole terminal blockand aluminium lugs for 4C X 25 sq. mm PVC insulated and PVC sheathed / XLPE, Armoured,aluminium conductor cable of 1.1 KV grade as required. 64 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(i).4C X 50 sq. mm 65 Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 x 150 Sqmm, PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete as required. 66 Supply of90 mm high density polyethylene HDPE pipe (PE- 80, PN-6) as per IS - 4984 with up to date amendment along with accessories like socket, bend, couplers etc. complete as required. 67 Supply of110 mm high density polyethylene HDPE pipe (PE- 80, PN-6) as per IS - 4984 with up to date amendment along with accessories like socket, bend, couplers etc. complete as required. 68 Laying of HDPE pipe (PE- 80, PN-6) of size up to110 mm (OD) in suitable depth by trencheless horizontal directional drilling (HDD) method by deploying HDD machines with necessary arrangements complete as required as per the site requirements.(Excluding the cost of HDPE Pipe) 69 Supply and fixing of outdoor use power point having Input (16 Amp x 5 Pin = 01 Plug) and Output (16 Amp x 3 Pin = 04 Socket, 16 Amp x 5 Pin = 02 Socket)with suitable Protection MCB & RCD mounting on the angle of 40mm X 40mm X 5mm including fixing in CC (1:3:6) foundation 300mm X 300mm X 300mm, with all accessoriesetccomplete as required.Make/Model:- PowerNPack/PDB02 or equivalent. 70 Numbering of GLF fittings with letters in yellow on black back ground as per inscription approved of Engineer in charge as required.
Contract Date: Oct 04, 2025 Contract Value : 1.40 Crore
Boards / Undertakings / PSU No of Bidders 3
25.
Defence #8519250 AOC
Rate Contract For Supply Of Kirloskar Make Generator Spare Parts , Rate Contract Of Generator Spare Parts For Kirloskar Make (Any Where In Hq 15 Corps Zone) , Special Washer - M14 Bolt Cart Part No 02.001.04.0.00 , Disc Plug Cart Part No 02.001.13.0.00 , Split Bush Cart Part No 02.001.14.0.00 , Coupling Disc Kg 42.3, Sae 11.5 Cart Part No 02.001.16.0.00 , Spring Washer(M8) Cart Part No 02.002.05.0.00 , Oil Spray Nozzle Assly Cart Part No 02.002.10.0.00 , Hard Washer 13 X21 X1.5 Cart Part No 02.005.04.0.00 , Scraper Ring Cart Part No 02.014.09.0.Pr , Inline Fip: Ha294 G1 20.5 Hp at 1500 Rpm Cpcb-Ii Cart Part No 02.015.04.0.00 , Shim Ring: Cyl Liner 0.2Thk Cart Part No 02.019.03.0.00 , Cylinder Liner Cart Part No 02.019.04.0.00 , Liner For Scraper Ring Cart Part No 02.019.08.0.Pr , Piston Pin Cart Part No 02.020.02.0.00 , Piston Ring Set Cart Part No 02.020.40.0.00 , Piston Assembly Cart Part No 02.020.50.0.00 , Piston Ring Set Alcan3r Cart Part No 02.020.60.0.00 , Small End Bush (S/F) Cart Part No 02.021.03.9.00 , Connecting Rod Bolt Cart Part No 02.021.04.0.00 , 3R1040tc Small End Bush Cart Part No 02.021.11.9.Pr , Cylinder Head Bolt 12X211 Cart Part No 02.022.03.0.00 , Washer Cart Part No 02.022.04.0.00 , Washer Cart Part No 02.022.06.0.00 , Button For Injector Yoke Cart Part No 02.022.07.0.00 , Locking Screw Cart Part No 02.022.09.0.00 , Valve Cup Cart Part No 02.022.11.0.00 , Valve Collet Cart Part No 02.022.12.0.00 , Valve Spring Cart Part No 02.022.13.0.00 , Valve Seat Insert -Inlet Cart Part No 02.022.15.0.00 , Valve Seat Insert -Exhaust Cart Part No 02.022.16.0.00 , Valve Guide Cart Part No 02.022.17.0.00 , Wire Snap Ring Cart Part No 02.022.18.0.00 , Spring Cup Cart Part No 02.022.21.0.00 , Nut M8 (Brass) Cart Part No 02.022.24.0.00 , Copper Washer Cart Part No 02.022.25.0.00 , Valve Collet-3-Groove Cart Part No 02.022.28.0.00 , Valve Seat Insert (Exhaust) Cart Part No 02.022.31.0.00 , Valve Seat Insert: Exhaust Cart Part No 02.022.31.7.00 , Cylinder Head Reconditioning Kit Ha Engine ( Bs Ii) Cart Part No 02.022.50.0.00 , Cylinder Head Reconditioning Kit Ha Engines (Indl Bsiii & Pg Cpcb) New Model (Post) Cart Part No 02.022.60.0.00 , Valve Tappet Cart Part No 02.024.01.0.00 , Sealing Ring Bottom Cart Part No 02.024.02.0.00 , Sealing Ring Cap Cart Part No 02.024.03.0.00 , Spring Cart Part No 02.024.04.0.00 , O Ring: Top P.R. Tube 5.3X17 21507 Cart Part No 02.024.05.0.00 , Washer Cart Part No 02.024.09.0.00 , Rocker Arm: Adj Screw Cart Part No 02.024.13.0.00 , Oil Metering Screw Cart Part No 02.024.14.0.00 , V.R.Toe Cart Part No 02.024.15.0.00 , Valve Rocker Assly Cart Part No 02.024.20.0.00 , Gasket For Rocker Cover Cart Part No 02.024.21.0.00 , Bush For Support Cart Part No 02.024.25.0.00 , Nut: Rocker Adj Screw Cart Part No 02.024.27.0.00 , Rocker Cover Cart Part No 02.024.32.0.00 , Push Rod Tube Cover: Ha Cart Part No 02.024.33.0.00 , Washer(Rocker Lever) Cart Part No 02.024.38.0.00 , Rocker Cover Gasket Cart Part No 02.024.41.0.00 , Push Rod: Welded Cart Part No 02.024.48.0.00 , Rocker Lever Assembly Cart Part No 02.024.50.0.00 , Push Rod: Welded Cart Part No 02.024.70.0.00 , Rocker Cover Gasket Cart Part No 02.024.97.0.00 , Nozzle Washer (Thickness - 3Mm) Cart Part No 02.025.01.0.00 , Expansion Module For Kg645 Cart Part No 02.026.10.0.Pr , Kg640i Controller Unit With Renesas Hardware Cart Part No 02.026.100.0.Pr , Genset Control Unit Gc2111 Cart Part No 02.026.11.0.Pr , Kg934 Front Facia Cart Part No 02.026.13.0.00 , Gc2112 Controller Unit Cart Part No 02.026.14.0.Pr , Kg645 C Controller Unitsp 3 Hardware 12V Cart Part No 02.026.26.0.Pr , Kg645 B Genset Control Unit Cart Part No 02.026.27.0.Pr , Kg640 Controller Unit (Sp-3 Hardware 12V) Cart Part No 02.026.31.0.Pr , Kg645 Controllerunit With 4-20Ma Cart Part No 02.026.32.0.Pr , Kg645e Controller Unit (Sp-3 Hardware 12V) Cart Part No 02.026.34.0.Pr , Kg640c Controller Unit For Cpcb4 Engine Cart Part No 02.026.36.0.Pr , Kg645c Dedicated For Png Dv8 Engine Configuration Cart Part No 02.026.37.0.Pr , Genset Control Unit Gc2111 Cart Part No 02.026.61.0.Pr , Ball Bearing (20X47x14) Cart Part No 02.027.05.0.00 , Rubber Grommet Cart Part No 02.029.04.0.00 , Injector With Conical Sac S Type Nozzle Cart Part No 02.030.03.0.00 , Injector Cart Part No 02.030.08.0.00 , Bush For Injector Cart Part No 02.035.08.0.00 , Rubber Sleeve Cart Part No 02.036.03.0.00 , Dipstick Guide Cart Part No 02.037.04.0.00 , Dual Banjo Bolt-M8 Cart Part No 02.037.06.0.00 , Joint : Exh Inlet Cart Part No 02.045.08.0.00 , Set Of Joints Cart Part No 02.050.10.0.Sp , Set Of O Rings: Ha294 Cart Part No 02.051.10.0.00 , Cylindrical Dowel Between Cr Case And F W Hsg Cart Part No 02.052.04.0.00 , Counter Weight Cart Part No 02.053.02.0.00 , Crankshaft Assly With Gear Cart Part No 02.053.10.0.00 , Lube Oil Pump Assly With Drvg Gear Cart Part No 02.056.50.0.00 , Air Inlet Mfold: Ha2 Finish Cart Part No 02.058.01.0.00 , Joint: Air Inlet Manifold Cart Part No 02.058.07.0.00 , Exhaust Mfold: Ha2 Cart Part No 02.059.01.0.00 , Set Of Joints Cart Part No 02.060.20.0.00 , Lower Cowling Cart Part No 02.061.01.0.00 , Top Air Baffle Cart Part No 02.062.01.0.00 , Rear Cowling Cart Part No 02.063.01.0.00 , Exhaust Air Baffle Cart Part No 02.064.10.0.00 , Cooling Air Blower Asslytwo Belt Cart Part No 02.067.20.0.00 , Upper Cowling Assly Cart Part No 02.068.10.0.00 , Breather Tube Cart Part No 02.069.01.0.00 , Stopper For Breather Tube Cart Part No 02.069.03.0.00 , V Belt: A46 Cart Part No 02.071.01.0.00 , Lub Oil Pipe Cart Part No 02.074.02.0.00 , Delivery Tube Cart Part No 02.081.01.0.00 , Sealing Ring - Lube Oil Cooler Cart Part No 02.083.02.0.00 , Lube Oil Cooler- Aluminium Cart Part No 02.083.04.0.00 , Rs485 High Voltage300v Ac Or 250 Dcprotection Kit Cart Part No 02.083.56.0.00 , Ecu For Gas Engine Cart Part No 02.086.01.0.Pr , Sub Assly Leak Off Pipe Cart Part No 02.088.20.0.00 , Exhaust Mfold Cum Silencer With Clip Cart Part No 02.091.01.0.00 , Fuel Pipe: 7.5 14X14b- 700 Wb Cart Part No 02.102.02.0.00 , Fuel Pipe Return Fip To Tank Cart Part No 02.102.13.0.00 , Front Cover Cart Part No 02.1031.01.0.00 , Headertopfor Spin On Filter Finish Cart Part No 02.1033.06.0.00 , Joint: Crankcase & Header Cart Part No 02.1033.09.0.00 , Header Assembly Cart Part No 02.1033.20.0.00 , Bracket: Alternator Cart Part No 02.1035.01.0.00 , Sae 1 Flywheel Housing Suitable For Dowel Mtg. Cart Part No 02.104.02.0.00 , Exhaust Manifold Cart Part No 02.1046.01.0.00 , Crank Pulley Cart Part No 02.1047.01.0.00 , Plate For Fuel Filter Mtg Cart Part No 02.112.01.0.00 , Flywheel Assly Cart Part No 02.116.10.0.00 , Wet Pm Kit (W/O Oil) For 02.1168 Cart Part No 02.116.8.0.Sp , Lever For Engine Stopping Cart Part No 02.118.01.0.00 , Sleeve: Nozzle Cart Part No 02.120.04.0.00 , Cylinder Head Assly Cart Part No 02.120.30.0.00 , Belt Guard : Frp Cart Part No 02.121.01.0.00 , Wiring Harness Tie 200Mm Lengthin Black Colour Cart Part No 02.1216.01.0.00 , Bearing Housing Cart Part No 02.124.01.0.00 , Crankcase Assembly Cart Part No 02.1263.10.0.00 , Crankcase Assembly Cart Part No 02.1263.20.0.00 , Belt (Avx 10 1500) Cart Part No 02.1266.01.0.00 , Belt: Avx 10 1545 Spz Cart Part No 02.1266.03.0.00 , Alternator Mtg Bracket Cart Part No 02.1268.01.0.00 , Piston Assembly Cart Part No 02.182.10.0.00 , Piston Ring Set (Tc) Cart Part No 02.182.30.0.00 , Cylinder Liner Cart Part No 02.183.01.0.00 , Joint For Cover Plate Cart Part No 02.187.24.0.Pr , Gasket For Iot Sensor For 20Kva R-Jio Cart Part No 02.187.28.0.Pr , Fuel Spout For R Jio Cart Part No 02.187.29.0.Pr , Wet Pm Kit (W/O Oil) For 02.2136... Cart Part No 02.213.6.0.Sp , Adaptor Pepper Pot Silencer Cart Part No 02.238.01.0.00 , Power Panel Assembly For Apu 3 5 Kw Cart Part No 02.240.40.0.Pr , 7 5Kw Apu Fuel Level Sensor Cart Part No 02.243.49.0.Pr , Set High Press Pipe Ha294 Cart Part No 02.298.90.0.00 , Air Inlet Manifold Sf Start Pilot Cart Part No 02.301.01.0.00 , Adaptor: Long Extension Shaft Belt Cart Part No 02.302.01.0.00 , Spinon Lube Filter Ctg Ha294 Cart Part No 02.320.02.0.00 , Exhaust Silencer Cart Part No 02.322.01.0.00 , Rain Cap Cart Part No 02.322.03.0.00 , Fuel Pipe: Nozzle Overflow To Fuel Tank Cart Part No 02.342.05.0.00 , Rubber Pad For Fuel Tank Mounting Cart Part No 02.347.03.0.00 , Special Stud For Fuel Tank Cart Part No 02.347.04.0.00 , Wiring Harness: Ha294 With Alt Cart Part No 02.365.20.0.00 , Dipstick Assly Cart Part No 02.401.10.0.00 , Fuel Pipe Return With Union Nut Cart Part No 02.408.05.0.00 , Fuel Pipe Inlet M14x15 Banjo One Side M16x15 Union Cart Part No 02.408.06.0.00 , Starter 12V Cart Part No 02.410.03.0.Pr , Fuel Level Gauge Mech:Dial 95 Mm Cart Part No 02.411.02.0.00 , Valve Pair: Ha Crome Plated Cart Part No 02.422.40.0.00 , Engine Safety Unit 12/24V 6 Led Cart Part No 02.424.02.0.00 , Esu 6Lpd Type: V Belt & Hooter O/P 12Vdc Cart Part No 02.424.05.0.00 , Washer (Id 13 X Od 30 X 5Th) For Alternator Cart Part No 02.430.03.0.00 , Hard Washer ( 11 I.D. X 19 O.D. X 1.5 Th ) Cart Part No 02.438.23.0.00 , Piston Assembly Cart Part No 02.443.35.0.00 , Piston Assembly Complete Cart Part No 02.443.50.0.00 , Valve Seat Insert-Inlet Cart Part No 02.445.04.0.00 , Valve Seat Insert -Exhaust Cart Part No 02.445.05.0.00 , Valve Pair Inlet & Exhaust Cart Part No 02.445.10.0.00 , Injector Cart Part No 02.447.08.0.00 , Cam Shaft & Gear Assembly Cart Part No 02.448.10.0.00 , Genset Power Panel Assemblysf Kg 541,For 3Ph Cart Part No 02.467.70.0.Pr , Control Panel Schematic For 15Kva3ph With Kg640 Ip A Cart Part No 02.468.80.0.Pr , Control Panel Schematic For 15Kva1ph With Kg640 Ip A Cart Part No 02.468.90.0.Pr , Control Panelschematicfor 15Kva 3Ph Ha2 With Kg640ip B Cart Part No 02.469.80.0.Pr , Control Panel Schematic For 15Kva Ha2 1Ph With Kg640ip B Cart Part No 02.469.90.0.Pr , Relay Card With 3 Relayfor Start Stop Cart Part No 02.472.25.0.00 , Stop Solenoid With 12V 10A 75Mm Cart Part No 02.477.01.0.00 , Sub Assembly Of Engine Stopping Lever Cart Part No 02.478.20.0.00 , Adaptor: Lube Oil Supply To Fp& Pr Gauge Sendor Cart Part No 02.480.04.0.00 , Fuel Pump: Ha294 Lla-Llr Cart Part No 02.480.10.0.00 , Injector Cart Part No 02.481.01.0.00 , Fuel Return Pipem12x1 5 Adaptor And M14x1 5 Union Nut Cart Part No 02.486.42.0.Pr , Anti Vibration Mounts Cart Part No 02.492.01.0.00 , Button For Inector Yoke Cart Part No 02.494.01.0.00 , Hose Clamp -Const Press Spr Band Cart Part No 02.500.08.0.00 , Nozzle Leak Off Pipe Cart Part No 02.500.30.0.00 , Digital Line Voltage Monitormodel Vmrd Msp Cart Part No 02.508.38.0.Pr , Deflector Plate ( Ha - Light Weight Ccase ) Cart Part No 02.519.06.0.00 , Joint: Front Cover Cart Part No 02.520.02.0.00 , Flywheel Assembly Cart Part No 02.523.10.0.00 , Flywheel: Sub Assly Cart Part No 02.523.20.0.00 , Fuel Hose 5.1 D X11.5 X12.7 O Cart Part No 02.525.06.0.00 , Combined Leak Off Pipe Nozzle To Fip Cart Part No 02.525.10.0.00 , Fuel Hosehp Leakoff Pipe To Tank Pipe Cart Part No 02.525.12.0.00 , Comb Leakoff Pipe Nozzle To Fip Cart Part No 02.525.20.0.00 , Combined Leak Off Pipe: Ha2 Cart Part No 02.525.50.0.00 , Fuel Filling Hose S Type Cart Part No 02.526.07.0.00 , Flywheel Housing Cart Part No 02.528.03.0.00 , Engine Mounting Foot G.E.( F.P. Side ) Cart Part No 02.532.01.0.00 , Engine Mounting Foot Ge (Fp Side) Cart Part No 02.532.02.0.00 , Engine Mounting Foot For Fwestarter Side Cart Part No 02.532.03.0.00 , Engine Mounting Foot For Fwefuel Pump Side Cart Part No 02.532.04.0.00 , Cam Shaft Assembly ( With 18 Mm Cam Gear ) Cart Part No 02.534.10.0.00 , Fuel Pump Gear Cart Part No 02.535.01.0.00 , Intermediate Gear Support Cart Part No 02.536.03.0.00 , Intermediate Gear Assembly Cart Part No 02.536.10.0.00 , Crankshaft Gear (18Mm Width) Cart Part No 02.537.01.0.00 , Crankshaft Assly With Gear Cart Part No 02.537.10.0.00 , Expansion Bellow Cart Part No 02.538.04.0.00 , Pipe For Expansion Bellow To Silencer Inlet( For Ha2 ) Cart Part No 02.538.06.0.00 , Residential Silencer Cart Part No 02.538.10.0.00 , Rain Cap Cart Part No 02.538.12.0.00 , Tail Pipe For Ha2 Cart Part No 02.538.29.0.00 , Silencer Cart Part No 02.538.50.0.00 , Silencer: Ha2 9 Dia Body Cart Part No 02.538.70.0.00 , Silencer Assembly Cart Part No 02.538.81.0.Pr , Lube Oil Sump Cart Part No 02.539.30.0.00 , Air Cleaner Element Cart Part No 02.541.02.0.00 , Belt (Ax60) Cart Part No 02.542.02.0.00 , Air Cleaner Element Cart Part No 02.542.05.0.00 , Bracket: Air Filter Cart Part No 02.542.06.0.00 , Air Cleaner Assly: Dry Type Cart Part No 02.542.10.0.00 , Air Inlet Hose Cart Part No 02.542.13.0.00 , Air Inlet Hose Cart Part No 02.542.18.0.00 , Hose For Air Cleaner Cart Part No 02.542.21.0.Pr , Dry Type Air Cleaner Assly For Ha2 Cart Part No 02.542.30.0.00 , Fuel Filling Hose Cart Part No 02.544.04.0.00 , Drain Pipe: Lube Oil Sump- Ha294 Cart Part No 02.544.05.0.00 , Expansion Bellow 2.5: 2Ply Cart Part No 02.545.06.0.00 , Hex Weld Nutm8x1 25 Cart Part No 02.554.02.0.00 , Hex Weld Nutm6x1 00 Cart Part No 02.554.05.0.00 , Hex Weld Nut -M4x0.7 Cart Part No 02.554.22.0.00 , Suction Tube Assly Cart Part No 02.556.10.0.00 , Wiring Harness Assly Cart Part No 02.567.10.0.00 , Engine Wiring Harness Cart Part No 02.570.10.0.00 , Front Cowling Cart Part No 02.571.05.0.00 , Rear Cowling Cart Part No 02.571.06.0.00 , Hot Air Ducting Cart Part No 02.571.20.0.00 , Hot Air Ducting: Com Side Open Cart Part No 02.571.30.0.00 , Hot Air Ducting Cart Part No 02.571.50.0.00 , Combined Leak Off Pipe Nozzle To Pump (M12 Banjo) Cart Part No 02.583.10.0.00 , Double Row Angular Contact Ball Bearing Cart Part No 02.585.03.0.00 , Fan: 1211 Blades S/F Cart Part No 02.589.01.0.00 , Adaptor On Crank Pulley For Fan Mountingc I Cart Part No 02.589.04.0.00 , Flywheel Hsgmachiningsae 1S F Cost Reduction Cart Part No 02.594.01.0.Sp , Flywheel Assly Cart Part No 02.595.10.0.00 , Piston Assembly Completeha294 Cpcb Ii Cart Part No 02.618.100.0.Pr , Piston Assembly Cart Part No 02.618.30.0.00 , Piston Assembly Cart Part No 02.618.80.0.00 , Set Of High Pressure Pipe: Ha294 Cart Part No 02.619.90.0.00 , Silencer Strip Clamp ( Hr Black Paint Cart Part No 02.627.05.0.00 , Belt: Spz Avx10 X 1564 Cart Part No 02.637.01.0.00 , 18 Blowing Fan 230V 1Ph 50Hz Ip 55 Cart Part No 02.638.05.0.00 , Exhaust Fan With Front Grill, 18,415V, 3 Phase, 1400 Rpm, 50Hz Cart Part No 02.638.69.0.Pr , Anti Vibration Mounts Cart Part No 02.650.01.0.00 , Anti Vibrn Mtg -Alternator Cart Part No 02.650.02.0.00 , Anti Vibration Mounts Cart Part No 02.650.03.0.00 , Kit Group Assembly For Conversion Of Horizontal Stop Solenoid To Vertical Pum Cart Part No 02.665.10.0.00 , Fuel Pump: Ha294 Cmvr Stage I Cart Part No 02.687.01.0.00 , Piston Assly 3 Ring Cmvr-Ii Cart Part No 02.689.30.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 02.692.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 02.692.02.0.00 , Fuel Pipe (Fuelfilter To Fuel Pump) Cart Part No 02.692.06.0.00 , Fuel Pipe(Feed Pump To Fuel Filter) Cart Part No 02.692.07.0.00 , Control Panel Assly Foriraq,With Electrical Lop/Lot Gause Cart Part No 02.700.10.0.00 , 12 V Dcrelay Board Two Relay Cart Part No 02.701.02.0.00 , Genset Control Unit Ems 927V3 V4 Cart Part No 02.709.05.0.00 , Glass Fuse 1Amp 20 Mm Cart Part No 02.709.22.0.00 , Super Capacitor 120F Ga Drawing With Mounting Cart Part No 02.709.27.0.Pr , Fuel Pipe Pre-Filter To Tank Cart Part No 02.712.06.0.00 , 12V Dc,110Ah,Smf Battery,Model :Smf N100 Cart Part No 02.731.40.0.00 , Fuel Inlet Pipe Cart Part No 02.751.12.0.00 , Fuel Inlet Pipem14x1 5 Banjo And M16x1 5 Union Nut Cart Part No 02.751.21.0.Pr , Plastic Fuel Spout And Cap Cart Part No 02.752.41.0.00 , Emergency Stop Push Button Protection Cart Part No 02.759.13.0.00 , Emergency Push Button With No Contactnon Lachable Cart Part No 02.759.14.0.Pr , Left Hand Lock With Catcher Padlock Arrangementupto 10 Kva Cart Part No 02.759.21.0.Pr , Right Hand Lock With Catcher Padlock Arrangementupto 10 Kva Cart Part No 02.759.22.0.Pr , Lever Lock For Canopy Cart Part No 02.759.23.0.Pr , Left Hand Lock With Catcher & Padlock Arrangement (Relience_Infra) Cart Part No 02.759.31.0.Pr , Right Hand Lock With Catcher & Padlock Arrangement (Relience_Infra) Cart Part No 02.759.32.0.Pr , Fuse Terminal Cart Part No 02.771.39.0.00 , Diode Forword Bais For Kg15st To Kg30st Alternator Type Cart Part No 02.804.12.0.00 , Diodereverse Bais For Kg15st To Kg30st Alternator Type Ta3a3 Cart Part No 02.804.13.0.00 , Excitor Rotor Assembly For Kg15st To Kg30st Alternator Type Ta3a5 Cart Part No 02.804.15.0.00 , Terminal Block: Kg15st-30St Cart Part No 02.804.21.0.00 , Rra Condenser Diode, Varistor Cart Part No 02.811.01.0.Asp , Sae 3, De Brkt- Prot. Screen Asly ? Kg28. Kva Rating:- (15-20, 1Ph & 20-30, 3Ph) Cart Part No 02.811.03.0.Asp , Excitor Stator-15/20 Kva 1 Phase Cart Part No 02.811.05.0.Asp , Exciter Rotor Cart Part No 02.811.06.0.Asp , Coupling Disc Set With Hardware- 15/20 Kva 1 Phase Cart Part No 02.811.09.0.Asp , Engine Wiring Harness Assembly Cart Part No 02.840.50.0.00 , Engine Wiring Harness Assly With Fuel Level Gems Sensor Cart Part No 02.840.60.0.00 , Junction Box (Ip55) Assembly Cart Part No 02.845.55.0.Pr , Lube Oil Pressure Switch Cart Part No 02.846.11.0.00 , Lube Oil Pressure Switch Cart Part No 02.846.12.0.Pr , Engine Wiring Harness Assembly Cart Part No 02.846.60.0.00 , Engine Wiring Harness Ha294 Sf Gc 2111 Unit Cart Part No 02.846.95.0.Pr , Engine Wiring Harness For 15Kva Ha2 Emerald Cart Part No 02.847.30.0.Pr , Engine Wiring Harness For 20Kva 1Ph Genset-Rjio Cart Part No 02.851.20.0.Pr , 12V Relay Board 1A-70A Cart Part No 02.854.57.0.00 , Nylon Cable Tie, Length: 1 Cart Part No 02.857.19.0.00 , 3 Phase 12V Rear Mounting W/O Display Cart Part No 02.859.06.0.00 , 1 Phase 12V Rear Mounting W/O Display Lvm Koel Cart Part No 02.859.09.0.00 , 12 Vdc Relay Board Three Channel Cart Part No 02.870.05.0.00 , Battery Charger 10A 12 Vdc Cart Part No 02.872.18.0.00 , Battery Charger 10A 12Vdc Cart Part No 02.872.22.0.Pr , 4 Pole 50 Amp Mcb Cart Part No 02.887.03.0.00 , Koel Green Alternatorkg 15 S Sframel Kg 42 3 Asae 2 11 5 230V50 Hz0 8 Pf Cart Part No 02.901.01.0.Pr , Koel Green Alternatorkg 15 S T Framel Kg 40 Esae 2 11 5 415V50 Hz0 8 Pf Cart Part No 02.901.03.0.Pr , Wiring Harness With Socket Cart Part No 02.910.10.0.00 , Wiring Harness From Engine To Amf Panel In Canopy Cart Part No 02.913.20.0.00 , Wiring Harness: 15Kva Cart Part No 02.920.20.0.00 , Fuel Tank Unit With 356 Effective Height Cart Part No 02.928.50.0.Pr , Assembly Of Air Guide Ring & Brush Cart Part No 02.930.10.0.00 , Wiring Harness Assly S/F Ha2 Cart Part No 02.935.10.0.00 , Wiring Harness Assly With Cld Cart Part No 02.938.20.0.00 , Wiring Harness Assly Cart Part No 02.938.70.0.00 , Current Transformer Cart Part No 02.944.08.0.00 , Double Pole Mcb 6A Cart Part No 02.944.11.0.00 , Power Terminal 50 Sq Mm Cart Part No 02.944.78.0.00 , Glass Fuse Link 15A 20 Mm Cart Part No 02.945.08.0.00 , Battery Tester Ut675a Uni T Cart Part No 02.950.05.0.Sp , Battery Cable Assembly21 Sq.Mm Cart Part No 02.950.10.0.00 , Control Panel Assembly Ha Ve Ve Cart Part No 02.958.10.0.Pr , Wiring Harness: Ha294 Industrial Va/Ve Cart Part No 02.958.30.0.00 , Control Panel Assembly Ha Va Ve Oem Based Cart Part No 02.959.10.0.Pr , Wiring Harness Assembly Ha294 Va Ve Oem Based Cart Part No 02.959.30.0.00 , 4Pin Powermate Male Housing Cart Part No 02.961.14.0.00 , 6Pin Powermate Male Housing Cart Part No 02.961.15.0.00 , 6 Pin Connector Cart Part No 02.961.16.0.00 , Connector Assembly For Control Panel With L0 Controller Cart Part No 02.961.60.0.00 , Single Pole Mcb 10A (A9n1p10c) Cart Part No 02.974.37.0.00 , Mccb100aftfm4pole Spreader Kit Cart Part No 02.974.77.0.Pr , Dse2157 Dsenet Output Expansion Module Cart Part No 02.991.33.0.00 , B Kit Overhaul Ha294 - Ktl Cart Part No 02.999.11.0.00 , Push Rod Kit: Ha2 Cart Part No 02.999.13.0.00 , One Time Filter Kit 0.5 Ltr Cart Part No 02.999.17.0.00 , Ha 294 (Pg) Service Kit - B Check Cart Part No 02.999.35.0.00 , Ha294 Sr Ii/394 Pg Serv Kit B Chk Cart Part No 02.999.36.0.00 , Ha294 (Pg) Service Kit With Air Filter C Chk Cart Part No 02.999.37.0.00 , Ha294 Sr Ii Pg Service Kit With Air Filter -C Check Cart Part No 02.999.38.0.00 , Wet Pm Kit (W/O Oil) For 02.2129,02.8303,02.2147,02.2122,02.8302,02.8312,02.8314 - Ha294 Cart Part No 02.999.38.0.Sp , Wet Pm Kitw O Oilfor 15Kva 02 8301 Ha294 G1 Cart Part No 02.999.45.0.Sp , Wet Pm Kit (W/O Oil) For 02.2119 ,02.2115-Ha-294 Cart Part No 02.999.46.0.Sp , Wet Pm Kit (W/O Oil) For 02.8306,02.8323,02.8331,02.8336,02.2129,02.9020,02.9006,02.8314,02.8 Cart Part No 02.999.48.0.Sp , Wet Pm Kit (W/O Oil) For 03.1143, 03.1176, 03.2004 - Ha394 Cart Part No 02.999.57.0.Sp , Half Overhaul Kit For Ha494 Cart Part No 02.999.60.0.00 , Wet Pm Kit (W/O Oil) For 02.2109.10 - Ha294 Cart Part No 02.999.78.0.Sp , Major Overhaul Kit Cart Part No 02.999.80.0.00 , Wet Pm Kit (W/O Oil) For 02.1144, 02.1158, 02.1204 - Ha294 Cart Part No 02.999.83.0.Sp , Wet Pm Kit (W/O Oil) For 02.1143, 02.1186 - Ha294 Cart Part No 02.999.84.0.Sp , Wet Pm Kit (W/O Oil) For 02.2133... - Ha2 Cart Part No 02.999.85.0.Sp , Wet Pm Kit (W/O Oil) For 02.2119 - Ha294 Cart Part No 02.999.86.0.Sp , Wet Pm Kit (W/O Oil) For 03.8906 - Ha394 Cart Part No 02.999.87.0.Sp , Conversion Kit From Kg 934 To Kg 645 Cart Part No 02.999.91.0.Sp , Conversion Kit From Kg 541 To Kg 645 For Dc Card Cart Part No 02.999.92.0.Sp , Conversion Kit From Kg 541 To Kg 645 For Ac+Dc Card Cart Part No 02.999.93.0.Sp , Conversion Kit From Kg 541 To Kg 640 For Dc Card Cart Part No 02.999.94.0.Sp , Conversion Kit From Kg 541 To Kg 640 For Ac+Dc Card Cart Part No 02.999.95.0.Sp , Conversion Kit From Kg 541 To Kg 640 For Chhota Chilli Cart Part No 02.999.96.0.Sp , Negative Insulated Starter 12 Vdc, 2 Wire - 2.7Kw Cart Part No 02.M801.09.0.00 , Cylinder Head Temperature Sensors Cart Part No 02.M801.10.0.00 , Cam Bush Cart Part No 03.001.04.0.00 , Screw Plug Cart Part No 03.001.06.0.00 , Slotted Pin Cart Part No 03.001.07.0.00 , Deflector Plate Cart Part No 03.001.08.0.00 , Precoated Stud (For Fuel Pump Mounting) Cart Part No 03.001.12.0.00 , Thrust Washer -Drive End,Top Cart Part No 03.001.19.0.00 , Thrust Washer (Drive End,Bottom) Cart Part No 03.001.21.0.00 , Bolt : Mb Cap Hex Head M14x2x128 Cart Part No 03.001.22.0.00 , Washerfor Fuel Pump Mounting Cart Part No 03.001.25.0.00 , Crankcase Assly W O Bearings Cart Part No 03.001.50.0.00 , Gasket: Fuel Pump Cart Part No 03.003.11.0.00 , Overflow Valve Assly Cart Part No 03.003.60.0.00 , Crankshaft Gear Cart Part No 03.005.02.0.00 , Thrust Washer For Camshaft Cart Part No 03.006.02.0.00 , Bush For Tachometer Cart Part No 03.006.03.0.00 , Camshaft Gear Cart Part No 03.006.04.0.00 , Camshaft & Gear Assly Cart Part No 03.006.10.0.00 , Oil Seal Housing: F Cart Part No 03.007.01.0.00 , Joint For Oil Seal Hsg Cart Part No 03.007.04.0.00 , Oil Seal(115X140x12) Cart Part No 03.007.06.0.00 , Rotary Shaft Seal Teflon Cart Part No 03.007.91.0.00 , Intermediate Gear Support Cart Part No 03.008.05.0.00 , Split Bush : Support Cart Part No 03.008.06.0.00 , Intermediate Gear Assly Cart Part No 03.008.10.0.00 , Screen Plate Cart Part No 03.010.02.0.00 , O Ring: L.O. Pump 1.57X65 - 21508 Cart Part No 03.010.11.0.00 , Relief Valve Cart Part No 03.010.13.0.00 , Spring: Relief Valve Cart Part No 03.010.14.0.00 , Lube Oil Pump Assly With Drvg Gear Cart Part No 03.010.50.0.00 , Union Screw Cart Part No 03.011.02.0.00 , Double Cone Ring Cart Part No 03.011.03.0.00 , Clip For Pipe Cart Part No 03.011.04.0.00 , O Ring: Delivery Tube: 3X14- 21508 Cart Part No 03.012.02.0.00 , Yoke Spring (Pipe Clamp) Cart Part No 03.012.04.0.00 , Delivery Tube Cart Part No 03.012.11.0.00 , Cover Cart Part No 03.013.03.0.00 , O Ring: 3X78 Silicone Cart Part No 03.013.04.0.00 , Joint: Front Cover Cart Part No 03.013.05.0.00 , Oil Seal (65X85x13) Cart Part No 03.013.06.0.00 , O Ring (3.2 X 78 Silicon) Cart Part No 03.013.11.0.00 , Joint For Front Cover( Asbestoss Free) Cart Part No 03.013.12.0.00 , Rotary Shaft Seal(Ge) Teflon Cart Part No 03.013.91.0.00 , Tachometer Plug Cart Part No 03.014.05.0.00 , Spring For Cup Cart Part No 03.014.06.0.00 , Sub Assembly Of Spring & Tachodrive Cup Cart Part No 03.014.10.0.00 , Bolt: Crank Pulley Updated 110Mm Cart Part No 03.016.02.0.00 , Washer: Crank Pulley Bolt Cart Part No 03.016.03.0.00 , Breather Tube Cart Part No 03.017.06.0.00 , Lower Cowling Cart Part No 03.019.01.0.00 , Rubber Grommet Cart Part No 03.019.05.0.00 , Union Screw Cart Part No 03.020.02.0.00 , Double Cone Ring Cart Part No 03.020.03.0.00 , Rubber Bush Cart Part No 03.020.05.0.00 , Spacer Cart Part No 03.020.06.0.00 , Sealing Ring Cart Part No 03.020.08.0.00 , Front Cowling Cart Part No 03.021.01.0.00 , Top Air Baffle Cart Part No 03.022.01.0.00 , Rubber Grommet Cart Part No 03.022.02.0.00 , Rubber Grommet Cart Part No 03.022.03.0.00 , Rear Cowling Cart Part No 03.023.01.0.00 , Special Plain Washer - M6 Cart Part No 03.023.02.0.00 , Assly Of Exh Air Baffle & Screen Plate Cart Part No 03.024.20.0.00 , Fan Pulley98 Pcda Section2 Grooves Cart Part No 03.025.15.0.00 , Assly Of Cooling Blower Cart Part No 03.025.40.0.00 , Banjo Bolt Cart Part No 03.027.04.0.00 , Leak Off Pipe Cart Part No 03.027.07.0.00 , Leak Off Pipe Assly Cart Part No 03.027.10.0.00 , Leak Off Pipe Sub Assly Cart Part No 03.027.20.0.00 , Cowling Assly: Welded Cart Part No 03.029.10.0.00 , Spacer(11 X 18 X18 L ) Cart Part No 03.030.05.0.00 , Screen Plate Assembly Cart Part No 03.033.10.0.00 , Starter 12V Cart Part No 03.034.01.0.00 , Starter Ring 121T 3.175Mod Cart Part No 03.035.02.0.00 , Bolt : Flywheel M10x35 Long Cart Part No 03.035.03.0.00 , O Ring: Dipstick 2X5 21515 Cart Part No 03.036.01.0.00 , Dipstick Assly Cart Part No 03.036.10.0.00 , Inlet Manifold Cart Part No 03.037.01.0.00 , V Belt A49 1278 Length Cart Part No 03.037.04.0.00 , Sealing Ring: Bowl 89X102x3.2T Cart Part No 03.040.03.0.00 , Banjo Bolt Cart Part No 03.040.06.0.00 , Joint: Lube Filter Asbestos Free Cart Part No 03.040.07.0.00 , Lube Oil Filter Header Cart Part No 03.040.11.0.00 , Lube Oil Filter Element Cart Part No 03.040.19.0.00 , Mounting Assly: Lube Oil Filter Cart Part No 03.041.10.0.00 , Blanking Plate Cart Part No 03.047.01.0.00 , Mud Slingerge Side Cart Part No 03.049.07.0.00 , Flywheel Bolt: M10x50 Cart Part No 03.050.02.0.00 , Flywheel Assembly Cart Part No 03.050.10.0.00 , Flywheel Assembly Cart Part No 03.050.20.0.00 , Flywheel Assembly Cart Part No 03.050.75.0.Pr , Fuel Pipe: Fuel Filter To Fip Cart Part No 03.052.03.0.00 , Bracket For Fuel Filter Cart Part No 03.052.06.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 03.052.07.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Inlet Cart Part No 03.052.08.0.00 , Fuel Pipe ( Feed Pump To Fuel Filter) Cart Part No 03.052.11.0.00 , Fuel Pipefuel Filter To Fip Cart Part No 03.052.12.0.00 , V Belt A49 1278 Length Cart Part No 03.054.01.0.00 , Gear End Foot Cart Part No 03.056.01.0.00 , Crankcase Foot Cart Part No 03.057.01.0.00 , Belt Guard Cart Part No 03.059.01.0.00 , Spacer For Belt Guard On Front Cover Cart Part No 03.059.03.0.00 , Spacer For Belt Guard On Bt Unit Cart Part No 03.059.04.0.00 , Hex Spacer For Belt Guard On Ge Foot Cart Part No 03.059.05.0.00 , Support For Belt Guard On Fan Body Cart Part No 03.059.06.0.00 , Spacer: Belt Guard Cart Part No 03.060.05.0.00 , Washer Cart Part No 03.060.08.0.00 , Support For Belt Guard On Fan Body Cart Part No 03.060.11.0.00 , Air Cleaner Assly Cart Part No 03.061.20.0.00 , Air Cleaner Clamp Cart Part No 03.061.21.0.00 , Bowl Cart Part No 03.061.22.0.00 , Sealing Ring Cart Part No 03.061.23.0.00 , Cone Ring Bet Bowl&Preclean Cart Part No 03.061.26.0.00 , Pre Cleaner For Air Cleaner Cart Part No 03.061.40.0.00 , Oil Bath Air Cleaner With Rubber Sleeve Cart Part No 03.061.70.0.00 , Bracket: Air Cleaner Cart Part No 03.063.01.0.00 , Hose For Air Cleaner: 70 Idx 80L Cart Part No 03.063.02.0.00 , Bracket Cart Part No 03.064.05.0.00 , Link For Ball Joint Cart Part No 03.064.07.0.00 , Bush Cart Part No 03.064.09.0.00 , Washer For Stopping Lever Cart Part No 03.064.11.0.00 , Sub Assembly Of Engine Stopping Lever Cart Part No 03.064.20.0.00 , Knurled Nut Cart Part No 03.065.04.0.00 , Spherical Washer Cart Part No 03.065.05.0.00 , Assly Speed Adjustment Unit S/F Cart Part No 03.065.30.0.00 , Adaptor: Temp Gauge Cart Part No 03.067.01.0.00 , Set Of Joints Cart Part No 03.068.10.0.Sp , Set Of Washers Cart Part No 03.068.12.0.00 , Set Of O Rings: Ha394 Cart Part No 03.069.10.0.00 , Set Of Copper Washer Cart Part No 03.069.30.0.00 , Gear End Foot Cart Part No 03.071.01.0.00 , Flywheel End Foot Fil Side Cart Part No 03.072.01.0.00 , Adaptor: Spin On Lof Cart Part No 03.075.10.0.00 , Lifting Hook Cart Part No 03.076.02.0.00 , O Ring: B.T. Unit 4X18-21511 Cart Part No 03.080.03.0.00 , B.T. Unit Sub Assly Cart Part No 03.080.90.0.00 , Belt Tension Unit With Actuator Cart Part No 03.080.91.0.00 , Leak Off Pipe Assly Cart Part No 03.081.10.0.00 , Cover For Flywheel Housing Cart Part No 03.086.02.0.00 , Flywheel Housing Cart Part No 03.086.03.0.00 , Gas Mixer Cart Part No 03.086.11.0.Pr , Crank Pulley Cart Part No 03.087.01.0.00 , Spacer ( 11 X 20 X 9 L ) Cart Part No 03.088.03.0.00 , Belt Tensioning Pulleyassembly Cart Part No 03.093.110.0.00 , B.T. Unit Assembly With Actuator Cart Part No 03.093.160.0.Pr , B.T. Unit Sub Assly Cart Part No 03.093.90.0.00 , Belt Tension Unit With Actuator Cart Part No 03.093.91.0.00 , Belt Tension Sub Assly With Actuator Cart Part No 03.093.92.0.00 , B.T. Unit Assembly With Actuator Cart Part No 03.093.93.0.00 , B.T. Unit Sub Assly & Actuator Cart Part No 03.093.94.0.00 , Rocker Cover Cart Part No 03.095.01.0.00 , Adaptor For Extension Shaft Cart Part No 03.096.01.0.00 , Rear Cowling Cart Part No 03.105.01.0.00 , Ducting & Cover Assembly For Hydraulic Cooler Cart Part No 03.106.20.0.00 , Bracket: Alternator Cart Part No 03.107.02.0.00 , Spacer (11X20x24 L ) Cart Part No 03.107.04.0.00 , Spacer ( 9X20x21l ) Cart Part No 03.107.05.0.00 , Flywheel Housing Cart Part No 03.108.03.0.00 , Special Washer Cart Part No 03.109.03.0.00 , Plate For Fuel Filter Cart Part No 03.113.01.0.00 , Plate For Fuel Filter Cart Part No 03.113.02.0.00 , Joint: Exhaust Bend Cart Part No 03.114.02.0.00 , Pin Cart Part No 03.117.02.0.00 , Adaptor For Tachodrive Cart Part No 03.117.04.0.00 , U Clamp Cart Part No 03.119.04.0.00 , Clamping Plate ( For U Clamp) Cart Part No 03.119.05.0.00 , Exhaust Manifold: Silencer With Clamp Cart Part No 03.119.20.0.00 , Rain Cap Sub Assly Cart Part No 03.120.20.0.00 , Rain Cap Sub Assly Cart Part No 03.120.30.0.00 , Sub Assembly Of Bend & Rain Cap Cart Part No 03.120.40.0.00 , Spacer Cart Part No 03.121.05.0.00 , Plate For Stopping Bar Cart Part No 03.121.06.0.00 , Sub-Assembly Of Guide Plate & Torsion Spring Cart Part No 03.121.20.0.00 , Ammeter -(50-0-50)Amps Cart Part No 03.124.01.0.00 , Alternator Pulley: 24V Cart Part No 03.128.01.0.00 , Bracket: Alternator Mtg Cart Part No 03.128.02.0.00 , Damping Bush Cart Part No 03.128.03.0.00 , Tension Adjusting Lever Cart Part No 03.128.06.0.00 , Bracket For Alternator Cart Part No 03.128.08.0.00 , Alternator: 24V Cart Part No 03.130.01.0.00 , Fan Pulley (82 Pcd, A Section, 2 Grooves) Cart Part No 03.135.04.0.00 , Impeller With Bush (Updated) Cart Part No 03.135.10.0.00 , Assly Of Cooling Blower Cart Part No 03.135.40.0.00 , Fan Body Stator & Impell Sub Assly Cart Part No 03.135.60.0.00 , Exhaust Fan, 12, 230Vac, 1400Rpm. Cart Part No 03.137.06.0.00 , Start Push Button Cart Part No 03.147.16.0.00 , Stop Push Button, (Xb5 Aa42n + 1No) Cart Part No 03.147.19.0.00 , Alternator: 12V 35A Cart Part No 03.148.05.0.00 , F002 G1b 704Chargine Alternator 12V, 35Amp With 2 Wire System Cart Part No 03.148.70.0.00 , Alternator Pulley F: 81 Pcd Cart Part No 03.149.01.0.00 , Spacer(11 X 20 X 6.5 L) Cart Part No 03.149.02.0.00 , Tension Adjusting Lever Cart Part No 03.149.03.0.00 , Spacer Cart Part No 03.180.08.0.00 , Spacer For Hot Air Ducting Cart Part No 03.180.12.0.00 , Spacer (Bar) Cart Part No 03.182.02.0.00 , Assembly A V Mtg Cart Part No 03.190.10.0.00 , Spacer Cart Part No 03.192.02.0.00 , Bracket For Stopping Bar Cart Part No 03.199.01.0.00 , Bracket For Prressure Gauge Sendor Unit Cart Part No 03.203.01.0.00 , Air Cleaner Bracket Cart Part No 03.203.25.0.00 , Hose: Air Cleaner Cart Part No 03.203.29.0.00 , Reducer Hose For Air Cleaner Cart Part No 03.203.33.0.00 , Exhaust Diffuser Cart Part No 03.203.34.0.00 , Hose For Air Cleaner Cart Part No 03.203.56.0.00 , Adaptor For Inlet Connection Cart Part No 03.208.02.0.00 , Wet Pm Kit (W/O Oil) For 03.2107,03.2145 Cart Part No 03.210.7.0.Sp , Rotex Solenoid Operated Fuel Magnet Valve Cart Part No 03.215.83.0.00 , Reciprocating Air Compressor Cart Part No 03.215.98.0.00 , Air Cleaner For Ha3 Engine Cart Part No 03.216.71.0.00 , 1 2Inch Bsp Straightmale Adaptor Length 42Mm A F 22 25Mm Id 14Mm Cart Part No 03.216.86.0.00 , Automatic Voltage Regulatoravr Cart Part No 03.217.24.0.00 , Fueltank For 7.5 Kw Apu Cart Part No 03.217.28.0.00 , Fuel Level Sensor Cum Switch Cart Part No 03.217.29.0.00 , Vulkan Coupling (Vulastik-Coupling Between Alternator & Compressor) Cart Part No 03.218.87.0.00 , Engine Wiring Harness For Hhp Apu Cart Part No 03.219.21.0.00 , Solenoid Drain Valve Kit Cart Part No 03.219.27.0.00 , Vulkan Coupling Between Alternator Compressor Megiflex B Coupling 1040S Cart Part No 03.219.49.0.00 , 1 Inch Bspp Swivel Elbowone Side Male One Side Swivel Female Cart Part No 03.219.57.0.00 , 1 2 Inch Bsp 90 Degelbowboth Side Malemoc Forged Steel 1000Psi Cart Part No 03.219.58.0.00 , Air Filterinsert Cart Part No 03.221.129.0.Sp , Air Filter Cart Part No 03.221.39.0.00 , 72V Dc Coil For 2 2 Direct Acting Normally Closed Solenoid Valvesolenoid Valv Cart Part No 03.221.66.0.00 , Fuel Strainer Cart Part No 03.222.62.0.00 , Vulkan Coupling (Vulastik-Coupling Between Alternator & Compressor) Cart Part No 03.222.95.0.00 , Exhaust Fan (450Mm) With Connector Cart Part No 03.224.01.0.00 , Exhaust Fan 15230V50hzflow Direction Motor To Blade Cart Part No 03.224.17.0.Pr , Current Transformer 30 52 5 Va Cart Part No 03.231.09.0.00 , Cam Shaft & Gear Assembly Cart Part No 03.236.10.0.00 , Cam Shaft & Gear Assembly Cart Part No 03.236.20.0.00 , Camshaft & Gear Assembly Cart Part No 03.236.40.0.00 , Flange For Starter Cart Part No 03.238.01.0.00 , Metalic Breather Pipe (Long) Cart Part No 03.239.01.0.00 , Mushroom Push Button Model Nozb5ac4with No Contact And Collar Cart Part No 03.240.82.0.00 , Amf65 Apu Controllertypeapumaster7 5Kw Cart Part No 03.240.83.0.00 , Amf65 Apu Controllertypeapuslave7 5Kw Cart Part No 03.240.84.0.00 , Fuel Pump Cart Part No 03.247.10.0.00 , Fuel Pipefilter Leak Off To Tank Cart Part No 03.248.02.0.Pr , Nozzle To Nozzle Leak Off Pipe Cart Part No 03.248.20.0.00 , Leak Off Pipe (Nozzle Leak Off To Filter Leak Off) Cart Part No 03.248.60.0.00 , Diode Forrectifier Unit Cart Part No 03.250.81.0.00 , Diode Forrectifier Unit Cart Part No 03.250.82.0.00 , Power Contactorac1 160A 48 130Vdcmodel No Af116 30 11 Cart Part No 03.250.93.0.00 , Power Contactor3p72v Dc Cart Part No 03.250.94.0.00 , Drain Pipe For Lub Oil Sump 320 Mm Cart Part No 03.254.07.0.00 , Anti Vibration Mounts Cart Part No 03.274.01.0.00 , Non Return Valve Cart Part No 03.291.13.0.00 , Adaptor M16x1.5 To 1/4 Bsp Cart Part No 03.291.16.0.00 , Pulley: Alternator 24V Spz Cart Part No 03.294.01.0.00 , Engine Wiring Harness Assembly Cart Part No 03.312.90.0.00 , Engine Wiring Harness Assembly Cart Part No 03.313.40.0.00 , Engine Wiring Harness Ha394with Rotry Pump Cart Part No 03.314.50.0.Pr , Stanadyne Rotary Fip For Ha394 Tci 40Hp 1500Rpmcpcbiiengine Cart Part No 03.340.04.0.00 , Inline Fip For Ha394tci G1 Engine -32 Hp @ 1500 Rpm Cart Part No 03.340.07.0.00 , Engine Wiring Harness Assembly(Without V Belt) Cart Part No 03.360.10.0.00 , Wiring Harness Cart Part No 03.360.20.0.00 , Silicon Coated Fiber Glass Clothsize After Forming 18X 14X 13With Fittings Cart Part No 03.423.51.0.00 , Assembly Of Hot Air Ducting ( Combined - Upward Open ) S/F Ha 394 Cart Part No 03.485.10.0.00 , Hot Air Ducting Assly: Side Open Cart Part No 03.485.20.0.00 , Wiring Harness With Pump Mounted Stop Solenoid Cart Part No 03.489.10.0.00 , Fuel Tank Assembly Cart Part No 03.503.10.0.00 , Bracket For Vsc Unit Cart Part No 03.508.01.0.00 , Bracket: Fixed Speed Ha294 Cart Part No 03.508.13.0.00 , Sub Assly Of V S Unit On F P Cart Part No 03.520.10.0.00 , Exhaust Mfold: Central Open Cart Part No 03.530.01.0.00 , Sub Assembly Of Exhaust Manifold And Adaptor Cart Part No 03.530.10.0.00 , Lube Oil Press Gauge Pipe 1.3M Cart Part No 03.593.01.0.00 , O Ring: Compressor Cart Part No 03.609.15.0.00 , O Ring: Cover Plate Cart Part No 03.609.17.0.00 , Cover Plate For Compressor Cart Part No 03.609.19.0.00 , Lub Oil Supply Pipe Assemblyccase To Comp Cart Part No 03.609.60.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 03.635.16.0.00 , Fuel Return Pipe Cart Part No 03.635.17.0.00 , Fuel Pipefeed Pump To Tank Unit Cart Part No 03.635.36.0.00 , Clamp For Dip Stick Guide Cart Part No 03.648.01.0.00 , Raised Dipstick Assly Cart Part No 03.648.50.0.00 , Du Fuel Filter 1.1 L W/O Valve Cart Part No 03.656.20.0.00 , Special Banjo Bolt(Losupply To Pump) Cart Part No 03.660.07.0.00 , Fuel Pump Assly Cart Part No 03.660.10.0.00 , Snap On Terminal Dowel Cart Part No 03.665.05.0.00 , Hub For Fuel Pump Gear Cart Part No 03.716.01.0.00 , Fuel Pump Gear Cart Part No 03.716.02.0.00 , Washer Fuel Pump Gear Cart Part No 03.716.03.0.00 , Eccentric Ring For Fip Gear Cart Part No 03.716.07.0.00 , Leak Off Pipe Assly Cart Part No 03.721.10.0.00 , Set Of High Press Pipe: Dha394 Cart Part No 03.723.90.0.00 , Front Cover Cart Part No 03.731.01.0.00 , Front Cover Cart Part No 03.731.05.0.00 , Inlet Cap For Oil Bath Air Cleaner Cart Part No 03.732.01.0.00 , Exhaust Manifold To Suit Tr 43 Turbo Charger Cart Part No 03.734.03.0.00 , Hose (Compressor Out) Cart Part No 03.734.04.0.00 , Lub Oil Drain Pipefront Cover Side Cart Part No 03.736.04.0.00 , Lub Oil Drain Pipeturbo Side Cart Part No 03.736.05.0.00 , Lube Oil Cooler- Aluminium Cart Part No 03.750.01.0.00 , Cac-In Pipe Assembly (Cac-Side) Cart Part No 03.752.10.0.00 , Adaptor: Press Gauge Sendor Cart Part No 03.769.02.0.00 , Joint For Cover Cart Part No 03.774.04.0.00 , Lube Oil Sump: Flat Face Cart Part No 03.829.30.0.00 , Suction Tube Cart Part No 03.830.20.0.00 , Wiring Harness Ha394 P.G.Engine With Alt Cart Part No 03.842.20.0.00 , Wiring Harness: Engine To Control Panel Cart Part No 03.907.20.0.00 , Adapter Ring For Sae1 To Sae2 Cart Part No 03.910.01.0.00 , Crankshaft Assly With Cr Gear Cart Part No 03.913.30.0.00 , Crankshaft Assembly Cart Part No 03.913.40.0.00 , Engine Start Push Button Cart Part No 03.918.17.0.00 , Engine Stop Push Button Cart Part No 03.918.18.0.00 , Fuel Filter 0.5 L Wo O-Ring Cart Part No 03.922.10.0.00 , Spinon Fuel Filter 0.6L Sbowl Cart Part No 03.922.40.0.00 , Fuel Filter Element Cart Part No 03.922.42.0.00 , Adaptor For Pricol Lube Oil Pressure Sensor Cart Part No 03.924.01.0.00 , Wiring Harness Assembly Ha3 Cart Part No 03.943.20.0.00 , Fuel Pump Variable Speed_ Ha394 Cmvr Stage I Cart Part No 03.947.01.0.00 , Punch For Disc Plug Cam Bore Cart Part No 03.950.20.0.00 , Mandrel For Oil Seal Ge Cart Part No 03.950.21.0.00 , Engine Safety Unit (Krb 203A With Timer For Cold Starting Aid) Cart Part No 03.963.02.0.00 , Off/On Selector Switch Cart Part No 03.963.19.0.00 , Selector Switch 2Way Cart Part No 03.963.22.0.00 , Emergencyswitch Cart Part No 03.963.23.0.00 , Flywheel Housing Cart Part No 03.974.01.0.00 , Flywheel Housingsae3 Cart Part No 03.974.03.0.00 , B Kit Overhaul Ha394 - Ktl Cart Part No 03.999.15.0.00 , Push Rod Kit: Ha3 Cart Part No 03.999.20.0.00 , Wet Pm Kit (W/O Oil) For 03.2106, 03.9003, 03.8803,03.8901, 03.8902, 03.8903 - Ha394 Cart Part No 03.999.25.0.Sp , Wet Pm Kit (W/O Oil) 03.2001, 03.2015 - Ha394 Cart Part No 03.999.27.0.Sp , Wet Pm Kit (W/O Oil) For 02.1174 - Ha294 Cart Part No 03.999.28.0.Sp , Wet Pm Kit (W/O Oil) For 03.107 - Ha394 Cart Part No 03.999.29.0.Sp , Ha394 Pg Service Kit With Air Filter C Check Cart Part No 03.999.35.0.00 , Wet Pm Kit (W/O Oil) For 03.2105 - Ha394 Cart Part No 03.999.89.0.Sp , Precoated Screw Plug Cart Part No 04.001.08.0.00 , Ccase Assly W/O Bearing Cart Part No 04.001.90.0.00 , Socket Head Bolt: M12x1.75X60 -10.9 Cart Part No 04.005.12.0.00 , Camshaft & Gear Assembly Cart Part No 04.006.30.0.00 , Camshaft And Gear Asslycmvr Stage Iii Cart Part No 04.006.40.0.00 , Comb Leak Off S/F Pipes: Ha4 Cart Part No 04.008.01.0.00 , Sub Assembly Leak Off Pipe (Industrial) Cart Part No 04.010.20.0.00 , Suctiontubesubassembly Cart Part No 04.011.40.0.00 , Exhaust Air Baffle Cart Part No 04.014.01.0.00 , Inlet Manifold Cart Part No 04.016.01.0.00 , Lower Cowling Cart Part No 04.019.01.0.00 , Lower Cowling For Ha494t Bs Iii Cart Part No 04.019.03.0.00 , Lube Oil Cooler Cart Part No 04.020.01.0.00 , O Ring: Lube Oil Cooler 2.5X26 -21502 Cart Part No 04.020.02.0.00 , Lube Oil Cooler: Ha494tc Cart Part No 04.020.03.0.00 , Top Air Baffle Cart Part No 04.021.01.0.00 , Upper Cowling Welded Assly Cart Part No 04.022.10.0.00 , Bolt: Flywheel-M10x45 Lg Cart Part No 04.024.02.0.00 , Subassembly Of Fw&Starter Ring Cart Part No 04.024.10.0.00 , Flywheel(C-108 Pto,Flexible Coup.Centa) Modified For Width Cart Part No 04.024.20.0.00 , Spacer (11X20x13.8L) Cart Part No 04.028.02.0.00 , Washer (Top) Cart Part No 04.030.02.0.00 , Anti Vibration Mounts Assly Cart Part No 04.030.20.0.00 , Torsional Vibration Damper Cart Part No 04.031.02.0.00 , Joint Cart Part No 04.032.02.0.00 , Hydraulic Pump Gear Cart Part No 04.032.03.0.00 , Lock Nut Cart Part No 04.032.04.0.00 , Flange Cart Part No 04.032.05.0.00 , O Ring Suction Flange 2 65X23 6I D Cart Part No 04.032.06.0.00 , Flange (Small) For Hyd Pump Cart Part No 04.032.07.0.00 , O Ring Del Flange2 5X19 21507 Cart Part No 04.032.08.0.00 , Ferrule For Delivery Pipe Cart Part No 04.032.12.0.00 , Flange (Outlet) Cart Part No 04.032.14.0.00 , Set Of Joints Cart Part No 04.034.10.0.Sp , Set Of Joints Cart Part No 04.034.20.0.Sp , Set Of O Rings Ha494 Cart Part No 04.035.10.0.00 , Plate For A V Mounting Cart Part No 04.037.01.0.00 , Flywheel Assly Cart Part No 04.039.10.0.00 , Bracket: Fuel Filter Cart Part No 04.040.04.0.00 , Stopping Bar Assembly Cart Part No 04.051.50.0.00 , Exhaust Mfold Cum Silencer Cart Part No 04.052.30.0.00 , V Belt : A48x 1252 Long Cart Part No 04.062.01.0.00 , Spacer: Bottom A V Mtg Cart Part No 04.080.01.0.00 , Assly Of Cooling Blower Cart Part No 04.081.10.0.00 , Fuel Pipe 80,14X14b,235 Cart Part No 04.089.01.0.00 , Flexible Pipe Lop Gauge (2.5 M Long) Cart Part No 04.091.01.0.00 , V Belt: Failure Switch Khd-224 5023 Cart Part No 04.106.01.0.00 , Hot Air Ducting Assly Cart Part No 04.108.10.0.00 , Exhaust Mfold: Ha4 Finish Cart Part No 04.110.01.0.00 , Start Key Switch Cart Part No 04.135.02.0.00 , Flywheel Assembly Cart Part No 04.135.10.0.00 , V Belt: A47 1227 Long Cart Part No 04.140.01.0.00 , Belt Guard Cart Part No 04.141.01.0.00 , Spacer (Bar) Cart Part No 04.141.03.0.00 , Breather: Box Type Cart Part No 04.157.01.0.00 , Crank Pulley: Narrow 2Gr Cart Part No 04.195.01.0.00 , Crank Pulleyfor Mud Slinger Cart Part No 04.195.05.0.00 , Bracket: V Belt Switch Cart Part No 04.196.02.0.00 , Pulley: Fan 98Pcd Spz 1Gr Cart Part No 04.197.01.0.00 , Alternator Pulley Cart Part No 04.198.01.0.00 , Spacer For B Tension Lever Cart Part No 04.198.04.0.00 , Hose: Air Cleaner Cart Part No 04.203.08.0.00 , Hose For Air Cleaner Cart Part No 04.203.09.0.Pr , Air Inlet Manifold Cart Part No 04.214.01.0.00 , Wet Pm Kit (W/O Oil) For 04.2421, 04.2445 - Ha494 Cart Part No 04.242.1.0.Sp , Overhaul Kit Ha494 Bsii Indl Appl Cart Part No 04.246.30.0.00 , V Belt Ax51 Raw Cog Lp1341 Cart Part No 04.249.01.0.00 , V Belt Cogged Ax49 Raw Edge Lp1279 Cart Part No 04.249.02.0.00 , V Belt: Lp1131 Ax43 Raw Edge Cogged Cart Part No 04.250.01.0.00 , Hub For Fuel Pump Gear Cart Part No 04.266.01.0.00 , Filter Header: Lube Oil & Fuel Filter Cart Part No 04.268.01.0.00 , Adaptor For Pr.Gauge Conn. Cart Part No 04.268.02.0.00 , Spinon Lube Oil Filter Cart Part No 04.270.01.0.00 , Spin On Filter For Lubricating Oil Cart Part No 04.270.08.0.Pr , Intermediate Ring(1 Mm Thk.) Cart Part No 04.291.03.0.00 , Intermediate Ring: 1.3Mm Cart Part No 04.291.06.0.00 , Intermediate Ring 1.5Mm Thk Cart Part No 04.291.11.0.00 , Intermediate Ring(2.0 Mm Thick) Cart Part No 04.291.22.0.00 , Cylinder Head Assly Cart Part No 04.291.30.0.00 , Sealing Washer Cart Part No 04.292.04.0.00 , Nozzle Cart Part No 04.295.01.0.00 , Washer For Inj Cart Part No 04.295.03.0.00 , Injector Cart Part No 04.295.10.0.00 , Fuel Filter Cartridge Cart Part No 04.296.01.0.00 , Sealing Ring For Filter(Khd No 111 8693) Cart Part No 04.296.02.0.00 , Lube Oil Supply Hose Cart Part No 04.304.02.0.00 , Inlet Manifold Cart Part No 04.308.01.0.00 , Exhaust Silencer: Ha494tc Cart Part No 04.329.01.0.00 , Exhaust Silencer (S/F L&T) Cart Part No 04.329.04.0.00 , Exhaust Silencer Cart Part No 04.329.07.0.00 , Crank Pulley (238 Pcd,3 Gr,A Sect) Cart Part No 04.334.05.0.00 , Wet Pm Kit (W/O Oil ) For 4H.3422 - Ha494 Cart Part No 04.342.2.0.Sp , Pull Type Accelarator Lever (Indital) Cart Part No 04.355.01.0.00 , Set Of High Press Pipe Cart Part No 04.358.90.0.00 , Rubber Sealing Ring Cart Part No 04.362.03.0.00 , Assembly Air Guide Ring & Brush Cart Part No 04.362.10.0.00 , Hose: Air Cleaner Cart Part No 04.363.02.0.00 , Exhaust Silencer: Tractor Short Cart Part No 04.364.04.0.00 , Exhaust Silencer Cart Part No 04.364.08.0.00 , Hose: Air Cleaner Cart Part No 04.364.11.0.00 , Sub Assly Flex Exh Pipe: 2.5Idx550l Cart Part No 04.364.20.0.00 , Flexible Pipe Sub Assly Cart Part No 04.364.40.0.00 , Alternator: 12V 55A Cart Part No 04.367.01.0.00 , Lube Oil Sump: Side Drain Cart Part No 04.375.01.0.00 , Adaptor: Lube Filter Ha2 Cart Part No 04.378.05.0.00 , Hose: Air Cleaner S/F 24 V Alt Cart Part No 04.387.02.0.00 , Main Element Forair Cleaner Cart Part No 04.403.11.0.00 , Air Cleaner Assembly Cart Part No 04.403.20.0.Pr , Fuel Pump Ha494 Non Cmvr Variable Speed Cart Part No 04.416.40.0.00 , Lube Oil Sump: Flat Face Cart Part No 04.417.30.0.00 , Lube Oil Sump Assly With Baffle Plate Cart Part No 04.417.31.0.Pr , Lube Oil Sump: Flat Face Cart Part No 04.417.50.0.00 , Fip Assly 9 5 Dia Cart Part No 04.422.20.0.00 , Suction Tube Assly: Press Sump Cart Part No 04.444.20.0.00 , Dipstick Assly: Press Sump 210-170X25-38 Cart Part No 04.445.10.0.00 , Wiring Harness With Alternator Cart Part No 04.450.20.0.00 , Suction Tube Cart Part No 04.451.20.0.00 , Drain Pipe For Lube Oil Sump Cart Part No 04.452.01.0.00 , U-Clamp For Sump Drain Pipe Cart Part No 04.452.03.0.00 , Adaptor For Sump Drain Cart Part No 04.452.06.0.00 , V Belt Cogged Spz-Lp1280 98 Pcd Cart Part No 04.465.01.0.00 , Belt Cart Part No 04.465.02.0.Pr , V Belt ( Spzx 1280L) Blower Fan Pulley Cart Part No 04.465.03.0.Pr , Banjo Bolt Cart Part No 04.474.05.0.00 , Rubber Hose: Air Inlet Cart Part No 04.475.01.0.00 , Actuator Adc225 Gs 12V With Lever Cart Part No 04.493.01.0.00 , Spacer For Bracket Cart Part No 04.499.01.0.00 , Spacer For Alternator Mtg Bracket Cart Part No 04.499.04.0.00 , Bracket For Cable Type And Low Idle Speed Adjustment Cart Part No 04.508.01.0.Pr , Fuel Pipe: Tank To Feed Pump 1700Mm Cart Part No 04.513.01.0.00 , Dipstick Assly Cart Part No 04.529.40.0.00 , Fuel Level Mech Gauge 160Mm Cart Part No 04.536.02.0.00 , Fuel Pipe Filter To Feed Pump Cart Part No 04.536.03.0.00 , Fuel Pipe Pre-Filter To Tank Unit Cart Part No 04.536.04.0.00 , Fuel Pipe (Inlet) M14 X 1.5 Banjo (Both Sides) Length 950Mm Cart Part No 04.536.11.0.00 , Fuel Pipe From Tank To Fuel Filter Cart Part No 04.536.21.0.Pr , Fuel Pipe From Fuel Filter To Tank Cart Part No 04.536.23.0.Pr , Fuel Pipe From Pre Filter To Fuel Transfer Pump Cart Part No 04.536.26.0.Pr , Fuel Pipe From Pre Filter To Fuel Junction Box Cart Part No 04.536.27.0.Pr , Fuel Pipe From Fuel Transfer Pump To Feed Pump Cart Part No 04.536.29.0.Pr , Wiring Harness: Engine To Control Panel Cart Part No 04.540.20.0.00 , Air Inlet Manifold Cart Part No 04.564.01.0.00 , Adaptor For Air Inlet Manifold Cart Part No 04.564.02.0.00 , Exhaust Manifold Finish With External Egr Arrengment For Ha4t Cmvr Iii Cart Part No 04.566.02.0.00 , Joint: Ejr Pipe: Ha Bsiii Cart Part No 04.566.04.0.00 , Turbocharger Cart Part No 04.568.10.0.00 , Hose: Lube Oil Drain Turbo Cart Part No 04.574.04.0.00 , Adaptor For Lube Oil Pipe On Cranckcase Cart Part No 04.574.06.0.00 , Clip For Lube Oil Inlet Pipe Cart Part No 04.574.07.0.00 , Bracket For Clip Mounting Cart Part No 04.574.08.0.00 , Rubber Sleeve For Lube Oil Pipe Cart Part No 04.574.09.0.00 , Exhaust Diffuser Cart Part No 04.575.01.0.00 , Joint: Exhaust Diffuser Cart Part No 04.575.04.0.00 , Spacer For Tension Lever Cart Part No 04.576.02.0.00 , Primary Air Cleaner Element Cart Part No 04.586.03.0.00 , Air Cleaner Safety Element Cart Part No 04.586.04.0.00 , Air Cleaner Assly+ Strainer Cart Part No 04.586.30.0.00 , Air Cleaner Assly: Dry Type Cart Part No 04.587.10.0.00 , Hose: Air Cleaner Cart Part No 04.588.02.0.00 , Restriction Indicator Cart Part No 04.588.05.0.00 , Hot Air Ducting Sf Ha494 Tc Engine With Kkk Turbocharger Cart Part No 04.592.10.0.00 , Sub Assembly Of Cam Shaft (Cpcb) With Chilled C.I. Cam Shaft Cart Part No 04.594.20.0.00 , Fuel Pump Assembly Cart Part No 04.595.10.0.00 , Injector Cart Part No 04.596.03.0.00 , Exhaust Silencer Cart Part No 04.599.01.0.00 , Rain Cap: Black Cart Part No 04.599.02.0.00 , Box Type Breather Cart Part No 04.600.01.0.00 , Wet Pm Kit (W/O Oil) For 4H.6007 Cart Part No 04.600.7.0.Sp , Adaptor For Exhaust Silencer Cart Part No 04.612.01.0.00 , Fuel Pipe (S/F041221)1400 L, 95 Id, 14 Banjo Cart Part No 04.613.01.0.00 , Expansion Bellow Cart Part No 04.625.02.0.00 , Silencer Cart Part No 04.625.10.0.00 , Hot Air Ducting Assly Cart Part No 04.666.10.0.00 , V Belt Cogged-Avx10 1265L Blower Pulley Cart Part No 04.668.01.0.00 , V Belt Coggedspax1260lblower Pulley Cart Part No 04.668.02.0.Pr , V Belt Cogged Avx 10-1136 For Alternator Pulley Cart Part No 04.669.01.0.00 , Assembly Air Guide Ring Cart Part No 04.670.10.0.00 , Starter: 12V 2.7Kw Cart Part No 04.677.01.0.00 , Valve Seat Insert: Exhaust Cart Part No 04.684.02.0.00 , Cylinder Head Assemblycomplete Cart Part No 04.684.70.0.00 , Con Rod Assly: Wo Le Brg Cart Part No 04.685.20.0.00 , Pulley: Fan 79Pcd Spz 1Gr Cart Part No 04.690.01.0.00 , Con Rod Assly: Mas Bal Wo Le Brg Cart Part No 04.691.20.0.00 , Connecting Rod Bolt Cart Part No 04.692.03.0.00 , Connecting Rod Assly Cart Part No 04.692.10.0.00 , Belt: Spzx Section Alt24v Lp1180 Cart Part No 04.708.01.0.00 , Adaptor For Rotary Fuel Pump Mounting Cart Part No 04.725.02.0.00 , Hub For Fip Gear Cart Part No 04.725.04.0.00 , Exhaust Manifoldfinish Cart Part No 04.734.03.0.00 , Turbocharger Cart Part No 04.735.02.0.00 , Joint: Turbo Inlet Cart Part No 04.750.02.0.00 , Joint: Lube Oil Outlet Flange Cart Part No 04.751.02.0.00 , Hose: Lube Oil Drain Ha494 Bs3 Cart Part No 04.751.03.0.00 , Lube Oil Drain Pipe: Front Cover Ha4 Cart Part No 04.751.05.0.00 , Turbo Oil Inlet Pipe Cart Part No 04.751.120.0.00 , Lube Oil Inlet Pipe Assly Cart Part No 04.751.60.0.00 , Cac Outlet Pipe To Inlet Manifold Cart Part No 04.752.01.0.00 , Hose (Cac Out) Cart Part No 04.752.03.0.00 , Hose (Cac-In) Cart Part No 04.752.08.0.00 , Intercooler Assembly For Ha4 Tcicpcb Ii Cart Part No 04.752.10.0.00 , Bracket For Fuel Filter Cart Part No 04.755.01.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 04.755.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 04.755.03.0.00 , Combine Leak Off Pipe Injector To Fuel Filter Cart Part No 04.755.06.0.00 , Fuel Pipefrom Combined Leakoff To Fuel Tank Cart Part No 04.755.07.0.00 , Comb Leak Off Pipe: Ha Bsiii Cart Part No 04.755.10.0.00 , Fuel Pipefeed Pump To Filter Cart Part No 04.755.16.0.Pr , Fuel Pipefuel Filter To Fuel Pump Cart Part No 04.755.18.0.Pr , Leakoff Pipe For Fuel Pump To Junctionbox Cart Part No 04.755.33.0.Pr , Primary Filter Element Cart Part No 04.760.01.0.00 , Safety Filter Element Cart Part No 04.760.02.0.00 , Air Cleaner Assly: Dry 8M3 Cart Part No 04.760.10.0.00 , Fuel Level Gauge Mech: Dial 140 Mm Cart Part No 04.768.03.0.00 , Wiring Harness S/ F Ha4 With Pump Mounted Stop Solenoid Cart Part No 04.773.10.0.00 , High Pressure Pipe Assly Cart Part No 04.785.90.0.00 , Engine Wiring Harness Assembly Cart Part No 04.786.60.0.00 , Engine Wiring Harness With Governor And Cold Start Cart Part No 04.786.81.0.00 , Exciter Rotor Cart Part No 04.805.15.0.00 , Terminal Block: Kg35st-125St Cart Part No 04.805.21.0.00 , Terminal Block For 225 Frame (Ta3l10) Cart Part No 04.805.38.0.00 , Terminal Block For 280 Frame (Ta3t10) Cart Part No 04.805.39.0.00 , Rotating Rectifier Assly For Kg200/225/280 Frame Kg35 To Kg200 Kva Altrnators Cart Part No 04.805.49.0.00 , Fuel Pump Cart Part No 04.813.10.0.00 , Nozzle Leak Off Pipe Cart Part No 04.815.20.0.00 , Assembly Instrument Panel With Meters Altr Hr Cart Part No 04.859.40.0.00 , 4 Pole Mcb 63 Amp Cart Part No 04.861.01.0.00 , Ems 18 Comunication Module For Rs 485 Out Put Cart Part No 04.931.11.0.00 , 1 Relay+Board, 12Vdc, 5A, 2C/O Cart Part No 04.942.07.0.00 , 1 Relay+Board, 24Vdc, 5A Cart Part No 04.942.08.0.00 , 1 Relay Board230vac5a Cart Part No 04.942.09.0.00 , Crankshaft Assly Integral Cart Part No 04.956.40.0.00 , Fip: Ha494 Tcicpcb-Ii Cart Part No 04.978.01.0.00 , Standyne Rotary Fip For Ha 494 Tci G1 Cart Part No 04.978.05.0.00 , Wet Pm Kit (W/O Oil) For 4.1153 - Ha494 Cart Part No 04.999.05.0.Sp , Wet Pm Kit (W/O Oil) For 04.8908 - Ha494tci G1 Cart Part No 04.999.06.0.Sp , Ha494 Pg Service Kit B Check Cart Part No 04.999.35.0.00 , Ha494 Pg Service Kit With Air Filter -C Chk Cart Part No 04.999.36.0.00 , Ha494 Cpcb Ii Service Kit - B Check Cart Part No 04.999.37.0.00 , Ha494 Cpcb Ii Service Kit With Air Filter - C Check Cart Part No 04.999.38.0.00 , Wet Pm Kit (W/O Oil) For 04.2145, 04.2121... Ha-494 Cart Part No 04.999.40.0.Sp , Wet Pm Kit (W/O Oil) For 4.8901,4.8904,3.8805- Ha494tci G1 Cart Part No 04.999.52.0.Sp , Wet Pm Kit (W/O Oil) For 04.2015 - Ha494 Cpcb Vertical Solonoid Cart Part No 04.999.56.0.Sp , Service Kit: 500Hrs Ha494 Bsiii Indl Transit Mixer Cart Part No 04.999.80.0.00 , Wet Pm Kit (W/O Oil ) For 04.9102 Cart Part No 04.999.81.0.Sp , Serv Kit A: 500 Hrs Ha494 Bsiii Indl Concrete Pump Cart Part No 04.999.85.0.00 , Wet Pm Kit (W/O Oil) For 04.8901 - Ha494 Cart Part No 04.999.86.0.Sp , Service Kit B 500 Hrs: Ha494 Bsiii Indl Concrete Pump Cart Part No 04.999.90.0.00 , Lub Oil Supply Hosec Case To Fuel Pump Cart Part No 04.M001.05.0.00 , Ccase Assly W/O Bearing Cart Part No 06.001.50.0.00 , Crankshaft Assembly Cart Part No 06.004.40.0.00 , Camshaft & Gear Assly Cart Part No 06.005.10.0.00 , Camshaft And Gear Assly Cmvr Ii Cart Part No 06.005.20.0.00 , Cam Shaft & Gear Assembly Cart Part No 06.005.50.0.00 , Comb Leak Off Pipe: Ha694 Cart Part No 06.006.01.0.00 , Union Screw Cart Part No 06.008.02.0.00 , Double Cone Ring Cart Part No 06.008.03.0.00 , Clamping Strap Cart Part No 06.008.04.0.00 , Sub Assembly Of Suction Tube Cart Part No 06.008.20.0.00 , Counter Sunk Socket Head Screw. Cart Part No 06.010.01.0.00 , Lub Oil Pump Assly Cart Part No 06.010.130.0.00 , Lube Oil Pump Assly Cart Part No 06.010.60.0.00 , Joint: Air Inlet Manifold To Cac Pipe Cart Part No 06.011.07.0.00 , Joint: Cac Pipe Cart Part No 06.011.08.0.00 , Cac-In Pipe ( Cac Side) Cart Part No 06.011.18.0.00 , Crank Pulley Assly Cart Part No 06.017.10.0.00 , Assly Of Crank Pulley ( Modified For Banded Belt) Cart Part No 06.017.40.0.00 , Lower Cowling Sub Assly Cart Part No 06.019.10.0.00 , Lower Cowlings Fmodified Cooler 06 1631 Cart Part No 06.019.40.0.00 , Lube Oil Cooler Cart Part No 06.020.01.0.00 , Sealing Ring Lube Oil Cooler Cart Part No 06.020.02.0.00 , Lube Oil Cooler -Ha6 Cart Part No 06.020.07.0.00 , Sealing Ring Cart Part No 06.020.08.0.Pr , Front Cowling Cart Part No 06.021.01.0.00 , Front Cowling Cart Part No 06.021.04.0.00 , Top Air Baffle Cart Part No 06.022.01.0.00 , Exhaust Air Baffle Cart Part No 06.024.10.0.00 , Ball Bearing(25X52x15) Cart Part No 06.025.13.0.00 , Fan Pulley (119 Pcd, A Section, 2 Grooves- Modified For Cart Part No 06.025.14.0.00 , Assly Of Cooling Blower Cart Part No 06.025.40.0.00 , Sub Assly Leak Off Pipe Cart Part No 06.027.20.0.00 , Air Inlet Manifold G.E.Opening Cart Part No 06.028.01.0.00 , Air Inlet Manifold Cart Part No 06.028.05.0.00 , Air Inlet Manifold Cart Part No 06.028.06.0.00 , Upper Cowling Cart Part No 06.029.10.0.00 , Banded Wrapped Belt 2Ja1310lp (1310 Mm Effective Pitch) Cart Part No 06.031.01.0.00 , Banded Cogged Belt: Lp1310 2Jax50 Cart Part No 06.031.04.0.00 , Banded Wrapped Belt 2Ja 51 -1328Mm Pitch Length Cart Part No 06.032.01.0.00 , Banded Wrapped Belt: 2Ja 52 1354 Long Cart Part No 06.032.02.0.00 , Belt :2Jax51 Lp -1326 Banded Cogged Cart Part No 06.032.03.0.00 , Belt: Lp1352 Banded Cogged 2Jax52 Cart Part No 06.032.04.0.00 , Starter Motor 12V 3Kw Cart Part No 06.033.01.0.00 , Starter 12V Cart Part No 06.034.02.0.00 , Starter 24V Cart Part No 06.034.06.0.00 , Hose: Inlet Manifold Cart Part No 06.037.01.0.00 , Hose: Inlet Manifold Cart Part No 06.037.03.0.00 , Lube Oil Filter Element Cart Part No 06.040.01.0.00 , Lube Oil Filter Assly Cart Part No 06.040.10.0.00 , Special Nut: Brass Cart Part No 06.046.02.0.00 , Exhaust Mfold Ge Top Open Cart Part No 06.046.10.0.00 , B.T. Unit Sub Assly Cart Part No 06.047.90.0.00 , Belt Tension Unit With Actuator Cart Part No 06.047.91.0.00 , Air Cleaner Oil Bath Cart Part No 06.048.01.0.00 , Pre Cleaner Cart Part No 06.048.02.0.00 , Clamp For Pre Cleaner Cart Part No 06.048.03.0.00 , Air Cleaner Clamp Cart Part No 06.048.05.0.00 , Air Cleaner Assly Cart Part No 06.048.10.0.00 , Bracket For Air Cleaner Cart Part No 06.049.01.0.00 , Hose: Air Cleaner Cart Part No 06.049.02.0.00 , Set Of Joints Cart Part No 06.050.10.0.Sp , Set Of O Rings: Ha694 Cart Part No 06.051.10.0.00 , V Belt : A 52 1354 Long Cart Part No 06.052.01.0.00 , Set Of High Pressure Pipe Cart Part No 06.055.90.0.00 , Rain Cap Cart Part No 06.065.20.0.00 , Sub Assembly Of Rain Cap With Modified Bend Cart Part No 06.065.30.0.00 , Sub Assembly Of Exhaust Cart Part No 06.066.20.0.00 , Exhaust Mfold: 4Cyl Cart Part No 06.069.01.0.00 , Exhaust Mfold: 2Cyl Cart Part No 06.069.02.0.00 , Compression Ring Cart Part No 06.069.03.0.00 , Compression Ring Cart Part No 06.069.04.0.00 , Joint (For Exh. Silencer) Cart Part No 06.069.07.0.00 , Exhaust Manifold4 Clysub Assly With Adaptor For Exhaust Silencer Cart Part No 06.069.20.0.00 , Spacer (Bar) For Actuator Cart Part No 06.072.03.0.00 , Stopping Bar Cart Part No 06.072.20.0.00 , Crankshaft Gear: Knurled Cart Part No 06.073.01.0.00 , Crankshaft Assly With Cr Gear Cart Part No 06.073.50.0.00 , Spacer Plate Cart Part No 06.074.14.0.00 , Gasket: 1.5Mm Thk Cart Part No 06.074.15.0.00 , Washer -Sheet Metal L.O.Sump Cart Part No 06.074.16.0.00 , Lube Oil Sump: Flat Face Cart Part No 06.074.30.0.00 , O Ring2 6X45 21511 Cart Part No 06.076.04.0.00 , Adaptor: Dipstick Assly Cart Part No 06.077.05.0.00 , Stop Solenoid 12V 20Mm Foot Mtg Cart Part No 06.081.01.0.00 , Mounting Plate (Lube Oil Filter Side) Cart Part No 06.082.02.0.00 , Mounting Plate (Starter Side) Cart Part No 06.082.03.0.00 , Ball Bearing(25X62x17) 6305Z,C3 Cart Part No 06.085.05.0.00 , Fan Pulley (90 Pcd A Section, 2 Grooves) Cart Part No 06.085.12.0.00 , Assly Cooling Blower Hyd Oil Cooler Cart Part No 06.085.40.0.00 , Fan Body Stator & Impell Sub Assly Cart Part No 06.085.60.0.00 , Fan Body: With Rubber Cart Part No 06.085.70.0.00 , Sub Assembly Of Fan Body, Stator And Impeller (Angular Bearing) Cart Part No 06.085.80.0.00 , Mounting Strap Cart Part No 06.086.03.0.00 , Vacuator Valve Cart Part No 06.086.04.0.00 , Temp Switch Cart Part No 06.087.02.0.00 , Ammeter (60-0-60 Amps) Cart Part No 06.087.06.0.00 , U Clamp Cart Part No 06.089.02.0.00 , Clamping Plate Cart Part No 06.089.03.0.00 , Clamping Plate ( S/F - 04.329.04.0.00 Silencer) Cart Part No 06.089.04.0.00 , U Clamp ( S/F - 04.329.04.0.00 Silencer) Cart Part No 06.089.05.0.00 , Clamping Plate Cart Part No 06.089.06.0.00 , U Clamp Cart Part No 06.089.07.0.00 , End Cover For Bell Housing Cart Part No 06.091.01.0.00 , Suction Tube Cart Part No 06.092.10.0.00 , Hub On Crank Pulley Cart Part No 06.097.01.0.00 , V Belt: A51 1328 Long Cart Part No 06.098.01.0.00 , Cowling Assly Cart Part No 06.101.10.0.00 , Spark Arrestor Cart Part No 06.105.01.0.00 , Solenoid Valve 12V Cart Part No 06.107.02.0.00 , Adaptor On Fuel Pump (Bar)(M12 X 15) Cart Part No 06.107.11.0.00 , Adaptor On Fuel Pump M14x1 5 Cart Part No 06.107.14.0.00 , Flame Heater 12V Cart Part No 06.107.16.0.00 , Fuel Pipe Solenoid To Heater Cart Part No 06.107.20.0.00 , Fuel Pipe Fip To Solenoid Cart Part No 06.107.30.0.00 , Fuel Pipe Assly Fuel Pump To Soln Sr2000 Cart Part No 06.107.40.0.00 , Flame Heater 24V System Cart Part No 06.108.01.0.00 , Solenoid Valve 24V Cart Part No 06.108.02.0.00 , Bimetal Switch 24 V Cart Part No 06.108.03.0.00 , Spacer 9X20x9thick Cart Part No 06.158.01.0.00 , Spacer(9X18x25thick) Cart Part No 06.158.02.0.00 , Fuse Holder With 100 Amp Fuse Cart Part No 06.1684.06.0.00 , Fip For Ha694 Tci Engine Cpcb Ii Cart Part No 06.1724.01.0.00 , Standyne Rotary Fip For Ha 694 Tci G1 Cart Part No 06.1724.22.0.00 , Spacer For Fuel Filter Cart Part No 06.211.01.0.00 , Plastic Tube: 500Mm Bar Cart Part No 06.216.01.0.00 , Plastic Tube For Breather Pipe 1200 Mm Cart Part No 06.216.94.0.Pr , One Pipe Exh Manifold F Cart Part No 06.219.01.0.00 , Two Pipe Exh Manifold F Cart Part No 06.219.02.0.00 , Sealing Ring Cart Part No 06.219.03.0.00 , Rubber Hose For Drain Pipes Cart Part No 06.224.11.0.00 , Assembly Of Lub Oil Inlet Pipe Cart Part No 06.224.30.0.00 , Nut (Special) Cart Part No 06.225.03.0.00 , Pre Cleaner Assly Cart Part No 06.229.20.0.00 , Pre Cleaner Assembly Cart Part No 06.229.60.0.00 , Silicon Coated Fiber Glass Clothsize After Forming 15X 7X 10With Fittings Fo Cart Part No 06.245.22.0.00 , Primary Filter Element Cart Part No 06.246.02.0.00 , Safety Air Filter Elemnt Cart Part No 06.246.03.0.00 , Dipstick Assly Cart Part No 06.248.10.0.00 , Air Inlet Manifold Cart Part No 06.254.01.0.00 , Adaptor: Bet Exh Mold & Turbo Cart Part No 06.255.01.0.00 , Bracket For Turbocharger Mounting Cart Part No 06.256.01.0.00 , Joint: Turbo Exh Outlet Cart Part No 06.256.03.0.00 , Hose: Air Cleaner Cart Part No 06.260.02.0.00 , Hose: Air Inlet Manifold Cart Part No 06.260.03.0.00 , Bracket For Alternator (24 V Gac 5R) Cart Part No 06.265.04.0.00 , Dowel Bolt For Alternator Cart Part No 06.265.05.0.00 , Tension Lever Cart Part No 06.265.06.0.00 , Exhaust Silencer: Ha694 Cart Part No 06.266.01.0.00 , Intermediate Ring: 1.1Mm Cart Part No 06.292.01.0.00 , Rain Cap Assly Cart Part No 06.309.02.0.00 , Clamp For Exhaust Pipe Cart Part No 06.309.04.0.00 , Bracket: Alternator Cart Part No 06.326.03.0.00 , Bush Cart Part No 06.326.09.0.00 , Tension Lever Cart Part No 06.326.13.0.00 , Fuel Pipe Feed Pump -Fuel Filter Cart Part No 06.333.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 06.333.02.0.00 , Bracket Cart Part No 06.333.03.0.00 , Bracket For Fuel Filter Cart Part No 06.333.07.0.00 , V Belt: Ax50 Lp1303 Raw Edge Cogged Cart Part No 06.337.01.0.00 , V Belt: Lp1254 Ax48 Raw Edge Cogged Cart Part No 06.338.01.0.00 , Rubber Hose: Air Cleaner 100X100x80l Cart Part No 06.347.03.0.00 , V Belt: Lp 1362 Ax52 Raw Edge Cogged Cart Part No 06.353.01.0.00 , V Belt Ax46 Raw Edge Cogged Cart Part No 06.354.01.0.00 , Hydraulic Pump Dowty Ip 3052 Cart Part No 06.357.02.0.00 , Adaptor On Unloader Valve Cart Part No 06.358.12.0.00 , Assly.Of Crank Pulley And Damper Cart Part No 06.363.10.0.00 , T Bolt Clamp Klipco Tb72/Jupitor ( 79 To 87 Dia) Cart Part No 06.376.03.0.00 , T Bolt Clamp Cart Part No 06.376.04.0.00 , Tbolt Clamp Klipco Tb64 Jupitor 50 To 64 Dia Cart Part No 06.376.05.0.00 , Tbolt Clamp (Range From Dia 116 To 123) Cart Part No 06.376.08.0.00 , Clamp For Battery Cart Part No 06.387.05.0.00 , Digital Temperature Switch Guage Cart Part No 06.387.41.0.00 , Sub Assly Of Cam Shaft Hyd Pump Cart Part No 06.389.10.0.00 , Inlet Manifold Cart Part No 06.398.01.0.00 , Hose: Air Cleaner Cart Part No 06.403.01.0.00 , Exhaust Diffuser (Upward Open) Cart Part No 06.420.01.0.00 , Set Of Joints Cart Part No 06.429.10.0.Sp , Spinon Lube Oil Filter Cart Part No 06.436.01.0.00 , Fuel Pump Assly Cart Part No 06.441.10.0.00 , Spacer 20 X 9 X 8.5 Th. Cart Part No 06.442.02.0.00 , Bracket For Air Cleaner Cart Part No 06.465.01.0.00 , Hose: Air Cleaner Cart Part No 06.465.03.0.00 , Flange For Exhaust Diffuser Down Open Cart Part No 06.468.02.0.00 , Joint: Exh Diffuser Cart Part No 06.468.03.0.00 , Joint: Exhaust Cart Part No 06.468.04.0.00 , Hot Air Ducting: Upward Opening Cart Part No 06.469.10.0.00 , Rubber Sealing Ring Cart Part No 06.471.03.0.00 , Assembly Air Guide Ring & Brush Cart Part No 06.471.10.0.00 , Set Of High Press Pipe: Dha694 Cart Part No 06.473.90.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 06.474.03.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 06.474.04.0.00 , Fuel Filter Element Assly Cart Part No 06.474.05.0.00 , Adaptor For Air Bleed Filter Cart Part No 06.474.19.0.00 , Fuel Pipe From Combined Leak Off To Tank Cart Part No 06.474.24.0.00 , Combined Leak Off Pipefrom Nozzle Leak Off To Filter Leak Off Cart Part No 06.474.25.0.00 , Fuel Filter Bsiii Ha494 Ha694 Cart Part No 06.474.50.0.00 , Front Cover Cart Part No 06.482.01.0.00 , Adaptor On Crank Pulley Cart Part No 06.484.06.0.00 , Fan: 390Mm Od 11 Blades Cart Part No 06.484.11.0.00 , Adaptor Forfan Cart Part No 06.484.12.0.00 , Exhaust Diffuser Upward Open Cart Part No 06.488.01.0.00 , Belt: Ax47, Lp1227 Raw Edge Cogged Cart Part No 06.491.01.0.00 , Fuel Pipe (Return) M12 X 15 Male Plug X M14 X 15 Banjo (900 Cart Part No 06.5001.21.0.00 , Fip Assly 9 5 Dia Cart Part No 06.527.30.0.00 , Fip Assly: 9.5 Dia Cart Part No 06.529.20.0.00 , Belt : Lp-1150 Ax44 Raw Edge Cogged Cart Part No 06.531.01.0.00 , Pre Cleaner Assly Cart Part No 06.550.20.0.00 , Pre Cleaner Cart Part No 06.550.50.0.00 , Suction Tube Cart Part No 06.555.20.0.00 , Assembly Iinstument Panel With Meters(Altr,Hr) Cart Part No 06.573.50.0.00 , Wiring Harness Ha694 P.G.Engine With Alt Cart Part No 06.574.20.0.00 , Adapter For Exhaust Silencer Cart Part No 06.586.02.0.00 , Left Hand Lock With Catcher (Upto 82.5 Kva) Cart Part No 06.597.94.0.00 , Lh Lock With Catcher 100-600 Kv Cart Part No 06.598.03.0.00 , Rh Lock With Catcher 100-600 Kva Cart Part No 06.598.04.0.00 , Rh Lock With Catcher To 82.5 Kva Cart Part No 06.598.05.0.00 , Expansion Bellow Assly 3 Cart Part No 06.602.10.0.00 , Hose Tail: Fuel Leak Off Conn Cart Part No 06.610.02.0.00 , Fuel Pipe: 9.5 I.D.X4000 L Cart Part No 06.610.03.0.00 , Adaptor For 2R1040 For Water Connection Cart Part No 06.610.08.0.00 , Hose Tail Connection S/F M14 Cart Part No 06.610.10.0.00 , Sleeve For Exhaust Silencer Cart Part No 06.628.02.0.00 , Valve Guide Cart Part No 06.631.01.0.00 , Valve Stem Seal Cart Part No 06.631.02.0.00 , Fuel Pipe Tank To Feed Pump Cart Part No 06.635.14.0.00 , Fuel Pipe 4Mtr And Clamps Cart Part No 06.654.10.0.00 , V Belt: Lp1176 Ax45 Raw Edge Cogged Cart Part No 06.672.01.0.00 , Lube Oil Sump Cart Part No 06.677.10.0.00 , Adaptor For Autotimer Cart Part No 06.699.01.0.00 , Fuel Pump Gear Cart Part No 06.699.02.0.00 , Leak Off Pipe Assly Cart Part No 06.711.10.0.00 , Rpm Indicator: Built In Regulator Cart Part No 06.712.01.0.00 , T- Bolt Clamp ( 90 Mm) Cart Part No 06.713.03.0.00 , Tbolt Clamp104 Mm Cart Part No 06.713.04.0.00 , Fuel Pipe (Return) M12x15 Male Plug X M14x15 Banjo Cart Part No 06.718.02.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 06.718.04.0.00 , Fuel Pipe Pre-Filter To Feed Pump Cart Part No 06.718.05.0.00 , Fuel Pipe Inlet: M14x1.5 Banjo Both Side 650Mm Cart Part No 06.718.11.0.00 , Cam Shaft & Gear Assembly Cart Part No 06.738.10.0.00 , Right Angle Adaptor For Sc160 Comp Cart Part No 06.751.01.0.00 , Banjo Bolt (M22x1.5) Cart Part No 06.751.06.0.00 , Banjo Coupling Cart Part No 06.751.40.0.00 , Primary Filter Element Cart Part No 06.757.03.0.00 , Safety Air Filter Elemnt Cart Part No 06.757.04.0.00 , Air Cleaner Assly + Strap Cart Part No 06.757.30.0.00 , Mounting Strap Assembly (For Air Cleaner) Cart Part No 06.757.40.0.00 , Air Cleaner Assly+ Strap Cart Part No 06.761.20.0.00 , Adaptor: Turbocharger Mounting Cart Part No 06.764.02.0.00 , Joint: Turbocharger Cart Part No 06.764.03.0.00 , Bracket For Turbocharger Mounting Cart Part No 06.765.01.0.00 , Swivel Adaptor Cart Part No 06.765.02.0.00 , Turbocharger Cart Part No 06.766.10.0.00 , Turbocharger Cart Part No 06.766.20.0.00 , Assembly Of Lube Oil Inlet Pipe Cart Part No 06.767.10.0.00 , Sub Assembly Of Lube Oil Drain Pipe (Long) Cart Part No 06.767.20.0.00 , Subassembly Of Lube Oil Drain Pipe Cart Part No 06.767.30.0.00 , Spacer For Footgear End Cart Part No 06.769.04.0.00 , Hose: Air Cleaner Cart Part No 06.770.01.0.00 , Plate For Air Cleaner Mounting Cart Part No 06.770.02.0.00 , Hose: Air Cleaner Cart Part No 06.770.03.0.00 , Dipstick Assembly Cart Part No 06.776.10.0.00 , Dipstick Assembly Cart Part No 06.776.30.0.00 , Expansion Bellow Cart Part No 06.786.20.0.00 , Stopping Bar For Stop Solenoid Cart Part No 06.791.01.0.00 , Stop Solenoid 24V Sing Coil 75 Dia Cart Part No 06.793.01.0.00 , Nozzle Leak Off Pipe Cart Part No 06.819.20.0.00 , Rubber Hose (82 X 82 X 90 Deg) For Air Cleaner Cart Part No 06.820.01.0.00 , Exhaust Bend ( 76.2 X 70.5 X 90 Deg ) Cart Part No 06.821.01.0.00 , Expansion Below (3.0) Cart Part No 06.821.04.0.00 , Assembly Air Guide Ringmount Cart Part No 06.866.10.0.00 , Electrical Dwgfor Anti Condensation Heater Control Panel230v Ac1 Ph 50Hz Cart Part No 06.875.25.0.Pr , Rubber Hose ( Turbo Air Outlet ) Cart Part No 06.886.04.0.00 , One Pipe Exhaust Manifold Cart Part No 06.887.01.0.00 , Joint: Egr Pipe-Ha6 Bsiii Cart Part No 06.887.07.0.00 , Joint For Egr Pipe 50 Crs Exhmanifold End Cart Part No 06.887.09.0.00 , Crankcasew O Bearing For Bs Iii Va Ve Cart Part No 06.890.40.0.00 , Adaptor On Crank Case Cart Part No 06.891.05.0.00 , Hose ( L.O Turbo Drain ) --S/F L.H.D --Sa Cart Part No 06.891.07.0.00 , Adaptor (On Crankcase For Torbo Inlet Pipe) Cart Part No 06.891.13.0.00 , Assembly Of Lube Oil Inlet Pipe Cart Part No 06.891.40.0.00 , Wiring Harnessfor Esu Unitside Mounted Control Panel Cart Part No 06.915.20.0.00 , Indicating Lamp Green- 240V Cart Part No 06.953.18.0.00 , Terminal Type Cts 2 5Un Cart Part No 06.953.38.0.00 , Wiring Harness With Pump Mounted Stop Solenoid Cart Part No 06.971.10.0.00 , Mounting Ring For Turbo Cart Part No 06.972.01.0.00 , Dog Bone For Kkk27 Turbo Cart Part No 06.972.02.0.00 , B.T. Unit Assly & Actuator Cart Part No 06.973.40.0.00 , Sub Assembly Of B.T Unit (Modified For Banded Belt) Cart Part No 06.973.60.0.00 , B.T Unit Assembly (Modified) With Actuator Plate Cart Part No 06.973.70.0.00 , B.T. Unit Sub Assly Modified Cart Part No 06.973.90.0.00 , Assembly Of Belt Tension Unit Cart Part No 06.973.95.0.00 , Relay 12 Vdc 100 Amp Capacitytype Bgr 215 Cart Part No 06.980.07.0.00 , Engine Wiring Harness For Ha694 S F 934 Unit Cart Part No 06.998.10.0.00 , Wet Pm Kit (W/O Oil) For 06.8901...,06.8903... - Ha694tci G1 Cart Part No 06.999.12.0.Sp , Wet Pm Kit (W/O Oil) For 6.2145 - Ha694 ( 12V Cpcb ) Cart Part No 06.999.13.0.Sp , Ha694 Cpcb Ii Service Kit - B Check Cart Part No 06.999.35.0.00 , Ha696 Cpcb Ii Service Kit With Air Filter - C Check Cart Part No 06.999.36.0.00 , Wet Pm Kit (W/O Oil) For 06.2445 - Ha694 Cart Part No 06.999.68.0.Sp , Wet Pm Kit (W/O Oil) For 06.2401, 06.2402 - Ha694tc Cpcb Vertical Solonoid Cart Part No 06.999.69.0.Sp , Wet Pm Kit (W/O Oil) For 06.2421 - Ha 694 Cart Part No 06.999.90.0.Sp , 6A, 1 Pole, Mcb Cart Part No 06.M801.17.0.00 , Core Plug For Oil Gallery Cart Part No 08.001.18.0.00 , Valve Stem Seal Cart Part No 08.010.12.0.00 , Hard Washer For Balancer Shaft Cart Part No 08.013.05.0.00 , Joint: Feed Pump Cart Part No 08.021.02.0.00 , Fork For Injector Cart Part No 08.030.04.0.00 , Steel Ball Hard 1/4 Dia Cart Part No 10.004.11.0.00 , Woodruff Key Cart Part No 10.007.02.0.00 , Key: Flywheel Cart Part No 10.007.03.0.00 , Jt Cr Case Fwe M B Hsgsspl Ss Ko 1243 Cart Part No 10.008.07.0.00 , Nut (7/16 Bsf) Cart Part No 10.011.04.0.00 , Stud: 5/16 Bsf X 1-5/16 Lg Cart Part No 10.013.08.0.00 , Valve Tappet (Steel) Av1 Cart Part No 10.016.04.0.00 , Governor Spring(1500 & 1800 Rpm) Cart Part No 10.018.02.0.00 , Governor Wt Assly: 1500 Rpm Cart Part No 10.018.10.0.00 , Hard Washer (F) Cart Part No 10.020.03.0.00 , Joint: F-Bkt & Adapt-Pl Cart Part No 10.024.07.0.00 , Joint: Adapt-Pl & Ccase Cart Part No 10.024.11.0.00 , Joint: Fp Bkt & Ccase Cart Part No 10.025.08.0.00 , Lead Seal (5945010300) Cart Part No 10.027.02.0.00 , Jointt-0010 Cart Part No 10.027.11.0.00 , Joint-0015 Cart Part No 10.027.12.0.00 , Joint: 0.005 Al Cart Part No 10.027.29.0.00 , Joint: Fp Bracket & Shims Cart Part No 10.027.35.0.00 , Washer For Injector Cart Part No 10.029.07.0.00 , Oil Seal Cart Part No 10.030.05.0.00 , Lube Oil Filter Element Cart Part No 10.031.05.0.00 , Jt-Rcover Cart Part No 10.033.01.0.00 , Sealing Ring - Fuel Filter(7.5X63.3) Cart Part No 10.034.03.0.00 , Element Fuel Filter With Grommet Av1 Cart Part No 10.034.13.0.00 , Joint: Water Flange Cart Part No 10.043.02.0.00 , P K Drive Screw 1/8X3/8 (Rivet) Cart Part No 10.046.02.0.00 , Extension Shaft (7.625 Long) Cart Part No 10.062.01.0.00 , Strainer Holder Cart Part No 10.079.02.0.00 , V Belt A-33 Cart Part No 10.122.05.0.00 , Joint: Water Inlet Mfold Cart Part No 10.323.03.0.00 , Gear Pump-Av1,Sr,With Rel.Valve Cart Part No 10.366.40.0.00 , Overload Stopper Assly Cart Part No 10.710.10.0.00 , Flywheel Key Puller Cart Part No 10.950.12.0.00 , Locking Pinffor Intbrg Hsg Cart Part No 11.002.04.0.00 , Gear Cover Plate Cart Part No 11.006.02.0.00 , Jt Gear Cover Plate& Ccase Cart Part No 11.006.04.0.00 , Rack Adjscrew(Twin Fuel Pump Linkage) Cart Part No 11.013.22.0.00 , Set Screw Cart Part No 11.013.23.0.00 , Jt Gear Cover& Gr Cover Plate Cart Part No 11.014.04.0.00 , Inspection Cover (F) - Av2 Cart Part No 11.015.01.0.00 , Joint: Insp Cover Cart Part No 11.015.03.0.00 , Fuel Filter Element -Av2 Cart Part No 11.018.04.0.00 , Govn Push Rodf W E Cart Part No 11.037.03.0.00 , Assly Of Gov Push Rod Gear Endtwin Cart Part No 11.037.20.0.00 , Dowelf Cart Part No 11.169.05.0.00 , Fuel Filter Element Cart Part No 11.203.09.0.00 , Bracket For Fuel Filter(C.I.) Cart Part No 11.203.19.0.00 , Fuel Filter Assly Cart Part No 11.203.50.0.00 , Fuel Filter Assly(0.5 Lit)(Vave) Cart Part No 11.203.95.0.00 , L O Pipe Assly -Ccase-Fwe Brg Hsg Cart Part No 11.242.10.0.00 , Washer For Cylinder Head Nut Cart Part No 12.001.06.0.00 , O Ring: Push Rod Tube Viton Cart Part No 12.005.05.0.00 , Rubber Bush: Bottom Cart Part No 12.005.08.0.00 , Support For Push Rod Tube Cart Part No 12.005.09.0.00 , Joint: Push Rod Tube Support Cart Part No 12.005.11.0.00 , V Belts A40 Cart Part No 12.020.03.0.00 , V Belt A-54 Cart Part No 12.034.01.0.00 , Cogged V Belt - Ax-54 Cart Part No 12.034.02.0.00 , Vsc Arrgmt.Cable Type Cart Part No 12.042.10.0.00 , Vsc Unit Assly With Bkt.& Cable.- Remote Cart Part No 12.143.10.0.00 , Fuel Pipe: Tank To Feed Pump Ta1/Ta2 Cart Part No 13.027.02.0.00 , Air Cleaner Element-Av2 Cart Part No 13.046.07.0.00 , O-Ring(28 Idx2.5,21509 Cart Part No 16.014.19.0.00 , Plug-Nylon Cart Part No 16.014.21.0.00 , Decom.Arrangement. Cart Part No 16.016.70.0.00 , Hollow Dowel Cart Part No 16.051.11.0.00 , Ring Set- Sv1 (Std.) Cart Part No 18.006.51.0.00 , Gasket-Head(Corpac)(Tv1/Ak65) Cart Part No 18.009.03.0.00 , Fuel Oil Strainer Cart Part No 18.011.26.0.00 , Filter Casing Assembly (Metallic Plug) Cart Part No 18.026.40.0.00 , Dipstick Assly With O Ring S/F Single Cyl.E Cart Part No 18.026.50.0.00 , Oil Filling Body - Tv1 Cart Part No 18.034.17.0.00 , Cap For Fuel Tanknew Cart Part No 18.051.61.0.00 , Dipstick Assembly Metallic Cart Part No 18.067.30.0.00 , Flexible Pipet To F Cart Part No 18.078.02.0.00 , Starter Ring Cart Part No 18.097.05.0.00 , Camshaft Extension Shaft 4.437Long Cart Part No 18.137.01.0.00 , Intermediate Bearing Housing Assly Tv2 Cart Part No 19.002.30.0.00 , Cr Shaft Cart Part No 19.003.30.0.00 , Cogged V Belt - Ax-53 Cart Part No 19.190.02.0.00 , Oil Seal Flywheel End 73 Od Clockwise Cart Part No 19.216.03.0.00 , Oil Seal Flywheel End Cart Part No 19.216.04.0.00 , Main Brg.Hsg(Fwe)Fw Hsg+Main Brg. Cart Part No 19.216.30.0.00 , Main Brg Hsg(Fwe) Fw Hsg+Main Brg Cart Part No 20.007.30.0.00 , Anti Vibration Mounts Cart Part No 20.367.01.0.00 , Joint For Adaptor Cart Part No 21.115.03.0.00 , Joint: Exh Adaptor Cart Part No 21.115.04.0.00 , Support For Altbracket Cart Part No 21.255.01.0.00 , Pulley For Alternator Cart Part No 21.255.02.0.00 , Lever Belt Tension For Alternator Cart Part No 21.255.03.0.00 , Alternator Bracket Finishe Series Agri Engines Cart Part No 21.255.06.0.00 , Extension Shaft For Crank Pulleyfinishbolted Crpulley Cart Part No 21.267.06.0.00 , Bolt For Crank Pulley Cart Part No 21.267.07.0.00 , Adaptor For Pressure Switch Cart Part No 21.279.02.0.00 , Lube Oil Press Sendor 0.75 +/- 0.15 B Cart Part No 21.279.04.0.00 , Adaptor For Sender Unit Cart Part No 21.343.01.0.00 , Wet Pm Kit (W/O Oil) For 21.1042 Cart Part No 21.999.08.0.Sp , Plug For Breather Tube Cart Part No 22.078.04.0.00 , Rubber Sleeve(12Dia) Cart Part No 22.118.01.0.00 , Rubber Sleeve (20Dia) Cart Part No 24.083.01.0.00 , Hard Washerbar Cart Part No 29.213.09.0.00 , R.E.Bearing M6 Rh Threads Cart Part No 29.224.28.0.00 , R.E.Bearing M6 Lh Threads Cart Part No 29.224.29.0.00 , Crankcase Assembly Cart Part No 2H.001.50.0.00 , Cam Shaft & Gear Assembly Cart Part No 2H.003.10.0.00 , Retaining Plate For Intermediate Gear Cart Part No 2H.004.04.0.00 , Support For Intermediate Gear Cart Part No 2H.004.11.0.00 , Joint: Gear Cover Cart Part No 2H.005.11.0.00 , Oil Seal Housing: Flywheel End Cart Part No 2H.006.01.0.00 , Joint For Oil Seal Housing Cart Part No 2H.006.11.0.00 , Plate: Rubber Moulding Cart Part No 2H.006.20.0.00 , O Ring: Cylinder Liner Cart Part No 2H.008.07.0.00 , Cyl Liner Assembly Cart Part No 2H.008.10.0.00 , O Ring: Cylinder Liner- Viton Cart Part No 2H.008.11.0.00 , Piston Assembly Cart Part No 2H.009.10.0.00 , Piston Ring Set 105 Dia Cart Part No 2H.009.30.0.00 , Piston Ring Set Cart Part No 2H.009.35.0.00 , Piston Ring Set Cart Part No 2H.009.55.0.00 , Hub: Fuel Pump Gear Cart Part No 2H.011.02.0.00 , Delivery Body Cart Part No 2H.013.01.0.00 , Delivery Body Cart Part No 2H.013.10.0.00 , Joint: Delivery Body Cart Part No 2H.013.11.0.00 , Delivery Tube Cart Part No 2H.014.01.0.00 , O Ring: Delivery Tube Cart Part No 2H.014.02.0.00 , Fuel Pump Cover With Joint Cart Part No 2H.017.10.0.00 , Joint For Cover For Fuel Pump Gear Cart Part No 2H.017.11.0.00 , Cover For Hydraulic Pump Gear Cart Part No 2H.018.01.0.00 , Joint: Hydraulic Pump Cover Cart Part No 2H.018.11.0.00 , Oil Metering Orifice Cart Part No 2H.022.06.0.00 , Injector Yoke Cart Part No 2H.023.01.0.00 , Injector Cart Part No 2H.023.10.0.00 , Nozzle Cart Part No 2H.023.91.0.00 , Clip For Breather Pipe Cart Part No 2H.028.03.0.00 , Joint: Air Inlet Manifold Cart Part No 2H.032.11.0.00 , Crank Pulley Cart Part No 2H.034.01.0.00 , Alternator Pulley Cart Part No 2H.034.02.0.Pr , Precoated Drain Plug Cart Part No 2H.035.02.0.00 , Drain Plug Assembly Cart Part No 2H.035.10.0.00 , Gear Casing Cart Part No 2H.036.01.0.00 , Gear Casing Cart Part No 2H.036.02.0.00 , Front Cover Cart Part No 2H.037.04.0.00 , Timing Pointer Cart Part No 2H.037.06.0.00 , Joint: Front Cover Cart Part No 2H.037.11.0.00 , Thrust Washer Cart Part No 2H.038.02.0.00 , Assly Intermediate Gear & Bush Cart Part No 2H.038.10.0.00 , Plate With Rubber Moulding: Oil Seal Housing Cart Part No 2H.039.10.0.00 , Earthing Bolt Of M10x35 For Shanti Projectrolled Brass Type Cart Part No 2H.046.03.0.00 , Earthing Nut For Shanti Brass M10x1 5 Cart Part No 2H.046.04.0.00 , Earthing Washerm10 Brass Cart Part No 2H.046.05.0.00 , Fuel Pump Cart Part No 2H.048.10.0.00 , Inline Fip For 2R1040 G1 Engine25 5 Hp 1500 Rpmcpcb Ii Cart Part No 2H.048.11.0.00 , Hose: Fuel Filling Hose 10 & 15 Kva Genset Cart Part No 2H.059.12.0.00 , Worm Drive Hose Clip (20-25 Mm) Cart Part No 2H.064.03.0.00 , Hose Thermostat To Radiator Cart Part No 2H.065.01.0.00 , Pipe Radiator To Pump Inlet Cart Part No 2H.065.02.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 2H.065.03.0.00 , Hose: Thermostat To Radiator Cart Part No 2H.065.06.0.00 , Hose: Radiator Outlet To Pump Inlet Cart Part No 2H.065.07.0.00 , Suction Tube Assembly Cart Part No 2H.071.30.0.00 , Leak Off Pipe Cart Part No 2H.088.03.0.00 , Leak Off Pipe Assly Cart Part No 2H.088.10.0.00 , Combined Leak Off Pipe: M12 Union Cart Part No 2H.088.20.0.00 , Lube Oil Pressure Sendor Cart Part No 2H.092.11.0.00 , Air Inlet Manifold Cart Part No 2H.094.01.0.00 , Inlet Manifold Cart Part No 2H.094.02.0.00 , R-121 Avr Cart Part No 2H.1025.10.0.00 , Joint: Rocker Cart Part No 2H.107.02.0.00 , Joint For Rocker Cover Cart Part No 2H.107.04.0.00 , Rocker Cover Cart Part No 2H.107.10.0.00 , L Oheader Assembly Cart Part No 2H.109.10.0.00 , Spring Band Clip Cart Part No 2H.112.01.0.00 , Worm Drive Clamp (29 To 45 Dia) Cart Part No 2H.112.02.0.00 , Spring Clamp (Constant Pressure Clamp) Cart Part No 2H.112.06.0.Pr , Hose Clamp 12 To 18 Mm Jupiter Cart Part No 2H.112.07.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 2H.116.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 2H.116.02.0.00 , Fuel Inlet Pipem14x15 Banjo M16x15 Union Nut Cart Part No 2H.116.12.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 2H.116.14.0.Pr , Fuel Inlet Pipe (M14x1.5 Banjo ) Cart Part No 2H.116.21.0.00 , Fuel Pipe Return With M14 Male Plug M14x1 5 Banjo Cart Part No 2H.116.22.0.00 , Pipe Union Bolt (M14 X 1.5) Cart Part No 2H.116.23.0.00 , Fuel Pipe Return With M12 Male Plugm14x1 5 Banjo Cart Part No 2H.116.26.0.Pr , Anti Vibration Mounts Cart Part No 2H.122.01.0.00 , Anti Vibration Mounts Cart Part No 2H.122.03.0.00 , Crankcase Foot (Gear End,Fuel Pump Side) Cart Part No 2H.124.03.0.00 , Crankcase Foot (Gear End,Starter Side) Cart Part No 2H.124.04.0.00 , Support For Mounting Foot Cart Part No 2H.124.05.0.00 , Bracket For Fuel Filter Cart Part No 2H.127.41.0.00 , 72V Dc Coil For Solenoid Drain Valve Cart Part No 2H.131.27.0.00 , Expansion Bellow: Exh Mfold Cart Part No 2H.135.02.0.00 , Expansion Bellow: Two Ply Cart Part No 2H.135.03.0.00 , Radiator Balance Water Tank Cart Part No 2H.139.05.0.00 , Radiator Fan: 15 Dia Pusher Cart Part No 2H.139.07.0.00 , Radiator Fan 17 Cart Part No 2H.139.65.0.00 , Copper Radiator Assembly Cart Part No 2H.139.70.0.Pr , Aluminium Radiator Assembly Cart Part No 2H.139.75.0.00 , Canopy Door Bidding 18Mm Dia. Bulb For Cpcb Project( 1 No = 1 Mtr ) Cart Part No 2H.148.01.0.00 , Canopy Door Switch2a250v Push To Off Cart Part No 2H.148.11.0.Pr , Silencer Cart Part No 2H.154.01.0.00 , Flange (At Silencer Inlet & Outlet) For 2R1040,3R1040 Silent Set Cart Part No 2H.154.02.0.00 , Silencer Flange Vave Cart Part No 2H.154.04.0.00 , Battery Stud For 17 5 Kva Silent Set Cart Part No 2H.160.04.0.00 , Silencer Assembly Cart Part No 2H.161.20.0.00 , Breather Pipe Cart Part No 2H.164.01.0.00 , Fuel Tank Unit S F 219 Effective Tank Height Cart Part No 2H.1649.31.0.Pr , Fuel Tank Unit S/F 230 Effective Tank Height Cart Part No 2H.1649.33.0.Pr , Silencer Cart Part No 2H.174.10.0.00 , Fuel Tank Unit Cart Part No 2H.177.19.0.Pr , Silencer Cart Part No 2H.188.10.0.00 , Bend For Tail Pipe Cart Part No 2H.193.02.0.00 , Feed Pump Cart Part No 2H.201.10.0.00 , Flywheel Assembly Cart Part No 2H.205.10.0.00 , Battery Charger Dc To Dc Converter I P Supply 60 To 90 Vdc Cart Part No 2H.226.26.0.00 , Dc Cti P0 150Ampo P 0 5 Vdccontrol Volatge5vdc 24Mm Id Cart Part No 2H.226.28.0.00 , Power Relay, 1 C/O, 2 Ch, 12V Dc, 70A Cart Part No 2H.226.32.0.00 , Relay, 2 C/O , 2Ch, 12Vdc, 5A Cart Part No 2H.226.33.0.00 , Battery Clamping Stud (M8) Cart Part No 2H.228.02.0.00 , Connector Assly: Control Panel With Kg934 Cart Part No 2H.241.60.0.00 , Connector Assembly For Control Panel With Kg645 Unit Cart Part No 2H.241.70.0.00 , Engine Wiring Harness Assembly Cart Part No 2H.268.20.0.00 , Engine Wiring Harness For 2R1040 Engine Cart Part No 2H.268.50.0.Pr , Engine Wiring Harness For 2R 20Kva Emerald Cart Part No 2H.268.70.0.Pr , Engine Wiring Harness Assembly Cart Part No 2H.269.50.0.00 , Engine Wiring Harness Assembly Cart Part No 2H.269.60.0.00 , Engine Wiring Harness Assembly Cart Part No 2H.269.70.0.00 , Rubber Hose: Air Cleaner Cart Part No 2H.277.03.0.00 , Primary Air Cleaner Element Cart Part No 2H.277.05.0.00 , Vacuuator Valve For Air Cleaner Cart Part No 2H.277.06.0.00 , Safety Element Forair Cleaner Cart Part No 2H.277.09.0.00 , Pvc Pipe For Air Cleaner Cart Part No 2H.277.19.0.00 , Air Cleaner Assly+ Strainer Cart Part No 2H.277.20.0.00 , Hose For Pvc Pipe Cart Part No 2H.277.21.0.00 , Hose For Pvc Pipe Cart Part No 2H.277.23.0.00 , Bracket For Air Cleaner Cart Part No 2H.277.24.0.00 , Hose For Air Cleaner Cart Part No 2H.277.26.0.00 , Assembly Of Air Cleaner (Air Cleaner + Strap + Rain Cap) Cart Part No 2H.277.40.0.00 , Dry Type Air Cleaner Assly For 2R Cart Part No 2H.277.90.0.00 , Adaptor For Lub Oil Pressure Switch Cart Part No 2H.279.21.0.00 , Starter 12Vdc 2 7Kw Suitable For 20 Deg Cart Part No 2H.301.02.0.Pr , Wet Pm Kit (W/O Oil ) For 2H.3014 - 2R1040 Cart Part No 2H.301.04.0.Sp , Wet Pm Kit (W/O Oil) For 2H.3017,2H.3020,2H.8303,2H.8306,2H.9024 - Model : 2R1040 Cart Part No 2H.301.7.0.Sp , Starter 12V 2.7Kw With Sealing Feature Cart Part No 2H.302.02.0.00 , 4 Pole 40 Amp Mcb Cart Part No 2H.313.01.0.00 , Pipe For Fuel Tank Breather With M12 X 1.5 Union Cart Part No 2H.316.08.0.00 , Anti Vibration Mounts Cart Part No 2H.332.01.0.00 , Anti Vibration Mounts Cart Part No 2H.332.02.0.00 , Anti Vibration Mounts Cart Part No 2H.332.04.0.00 , Anti Vibration Mount Cart Part No 2H.332.05.0.00 , Anti Vibration Mount For Radiator Cart Part No 2H.332.08.0.Pr , Sealing Washer Cart Part No 2H.345.32.0.Pr , Plastic Fuel Filling Spout With Lock Mesh Cart Part No 2H.345.36.0.Pr , Current Transfarmor 50/5, 2.5 Va Cart Part No 2H.467.04.0.00 , Amf Control Panel For 14Kw Dg Setreliance Jio Cart Part No 2H.471.40.0.00 , Coil, 220V Ac, 50Hz, Contactor 4 Pole, Type: Type-Lc1e80004m5wb) Cart Part No 2H.471.86.0.00 , Conversion Kit Kg934 To Kg645w O Controller For Dc Interface Card Cart Part No 2H.472.30.0.Pr , Conversion Kit Kg934 To Kg645w O Controllerfor Ac Dc Interface Card Old Type Cart Part No 2H.472.40.0.Pr , Canopy Wiring Harness For 2R1040 Genset Cart Part No 2H.481.40.0.Pr , Hose: Air Cleaner Cart Part No 2H.542.06.0.00 , Expansion Bellow 270Mm Cart Part No 2H.545.01.0.00 , Pad Lock For Canopy Cart Part No 2H.561.32.0.00 , Control Panel Schematic For 20Kva3ph With Kg640 Ip A Cart Part No 2H.764.60.0.Pr , Varistor For Kgs 160And Kgs180 Alt. Frame Alt. Frame Cart Part No 2H.811.05.0.00 , Kirloskar Green Avr (Model : Tavr-10/Tavr-20/Tavr-14 Cart Part No 2H.811.32.0.00 , Koel Green Avr: Suitable To External Adjust Potentiometer Cart Part No 2H.811.33.0.00 , Rotating Rectifier Assembly With Forward And Reverse Diode Cart Part No 2H.811.35.0.00 , Excitor Rotor Assembly(16A105) S/F Kg164e,Kg164f,Kg164g Cart Part No 2H.811.36.0.00 , Excitor Rotor Assembly(16S105)S/Fkg164h,Kg164j,Kg184a,Kg184b,Kg184c,Kg184d Cart Part No 2H.811.37.0.00 , Excitor Stator Assembly(16A106)S/Fkg164e,Kg164f,Kg164g Cart Part No 2H.811.38.0.00 , Excitor Stator Assembly(16S106)S/Fkg164h,Kg164j,Kg184a,Kg184b,Kg184c,Kg184d. Cart Part No 2H.811.39.0.00 , Terminal Block(16A110)S/F Kg.164E,Kg164f,Kg164g,Kg164h,Kg164j,Kg184a,Kg184b,Kg184 Cart Part No 2H.811.42.0.00 , Fan With Key For 164 Frame (16A108) Cart Part No 2H.811.43.0.00 , Flexible Discs Cart Part No 2H.811.73.0.00 , Koel Green Alternatorkg 20 S T Framel Kg 40 Hsae 2 11 5 415V50 Hz0 8 Pf Cart Part No 2H.817.14.0.Pr , Koel Green Alternatorkg 20 S S Framel Kg 42 3 Csae 2 11 5 230V50 Hz0 8 Pf Cart Part No 2H.818.14.0.Pr , D120 Avr Cart Part No 2H.818.15.0.00 , Koel Green Alternator Kg42 3Csae3 11 520Kva 20Kw At Upf230 V50 Hz Cart Part No 2H.818.16.0.Pr , Avr (Model- Tavr27) Cart Part No 2H.818.35.0.00 , Wet Pm Kit (W/O Oil) For 2H.8307.10 Cart Part No 2H.830.7.0.Sp , Fuel Level Sensor 110Mm Height(Pricol C20 5289) Cart Part No 2H.850.14.0.00 , Hour Meter Cart Part No 2H.857.06.0.Pr , Indicating Lamp 12 V Dc Green Colour Type-3Plbr3l Cart Part No 2H.864.12.0.00 , Indicating Lamp 12 V Dc Red Colour Type-3Plbr4l Cart Part No 2H.864.13.0.00 , Control Relay 12Vdc 3Chanel Cart Part No 2H.865.52.0.00 , Canopy Temperature Switch 2 - 85 Deg C Cart Part No 2H.865.56.0.00 , Neutral Linck 10 A Capacity Cart Part No 2H.866.07.0.00 , Earthing Cable (Braded) Forgenset 4Mm Dia. With Suitable Lug. Alt. To Base Plate Cart Part No 2H.868.02.0.00 , Lvm: 2C/O 3Ph Wo Phase Sequence Monitoring Cart Part No 2H.871.05.0.00 , Battery Charger 12V10a Cart Part No 2H.872.23.0.Pr , Digital Line Voltage Monitor Pr-07 Cart Part No 2H.875.02.0.00 , Selector Switch 3 Way With Off, 3 Pole Cart Part No 2H.876.04.0.00 , Relay Board 2Ch. 2C/O 12 V Din Mounted Cart Part No 2H.876.05.0.00 , Current Transformer 200 5A 2 5Va Cl 1 0Typene 310 Cart Part No 2H.880.11.0.Pr , 1 Amp Single Pole Mcb Cart Part No 2H.881.05.0.00 , 0 5 Amp Single Pole Mcb Cart Part No 2H.881.07.0.Pr , Fuse Blown Indicator 12 /24 Vdc Black Colour R Cart Part No 2H.892.09.0.00 , End Plates For4 Sq Mmterminal Stripsqty As Req Cart Part No 2H.892.12.0.00 , Water Tempsensor Cart Part No 2H.910.01.0.Pr , Mandrel For Intermediate Gear Mounting With Bush Cart Part No 2H.950.10.0.00 , Gasketfor L Series Governor Mounting Cart Part No 2H.956.01.0.00 , Header (For Locooler & Spin-On-Filter) Cart Part No 2H.964.01.0.00 , Header For Lube Oil Cooler & Spin On Filter (3 Plates) Cart Part No 2H.964.03.0.00 , Header: Spin On Filter Wo Cooler Cart Part No 2H.964.04.0.00 , Crankshaft Assembly Cart Part No 2H.966.10.0.00 , Crankshaft Assembly Cart Part No 2H.966.20.0.00 , 12V Relay Board-70 Amp Cart Part No 2H.970.02.0.00 , Auxillary Contact Block 2No 2Nctype Laen22 Cs94114oooo Cart Part No 2H.974.32.0.00 , Auxillary Contact Block Cart Part No 2H.974.37.0.Pr , Mcb 10A 1P C Curvetype A9n1p10c Bb10100c Cart Part No 2H.974.42.0.Pr , Contactor 100A 4P Ac1 With 220Vac Coil Type Cart Part No 2H.974.46.0.00 , Mechnical Inter Lock Type Laem4 Cs93095oooo Cart Part No 2H.974.47.0.Pr , Surge Suppressor Type Laercu Cs94163booo Cart Part No 2H.974.48.0.Pr , Mccb 100A 2P 3Ptype Ezc100h2100 Du100 Cart Part No 2H.974.55.0.Pr , Contactor 60A 63A 4P Ac1 With220vac Coiltype Lc1e38004m5wb240vac Coilcs970 Cart Part No 2H.974.58.0.Pr , Contactor Mcx1380a4pac1 With 240Vac Coil Voltage Cart Part No 2H.974.63.0.Pr , Mcb6a,1Pc-Curve,Type-Auseries Cart Part No 2H.974.66.0.Pr , Mcb2a,1Pc-Curve Cart Part No 2H.974.69.0.Pr , Contactor 95 A 3P Ac1 With (240Vac Coil, Type- Lc1e95u5/ 240Vac Coil) Cart Part No 2H.974.82.0.Pr , Mcb4a,1Pc-Curve Cart Part No 2H.974.91.0.Pr , Mcb 32A,1P C-Curve, Type-Au Series Cart Part No 2H.974.92.0.Pr , 100A Wide Band Contactor-240V,50Hz Cart Part No 2H.974.93.0.Pr , Terminal Bar- 30/40 Kva 1 Phase, 45/75Kva 3Phase Cart Part No 2H.976.01.0.00 , Exciter Rotor Cart Part No 2H.976.07.0.00 , Rra Aassembly Cart Part No 2H.976.08.0.00 , Wound Exciter Rotorrating5 To 12 5 Kva 1Ph7 5 To 20 Kva 3Ph Sem040ro002b Fr Cart Part No 2H.976.17.0.00 , Wound Exciter Statorrating5 To 12 5 Kva 1Ph7 5 To 20 Kva 3Ph Sem040st001b Fr Cart Part No 2H.976.18.0.00 , Fan, Rating 5 To 12.5 Kva Cart Part No 2H.976.19.0.00 , Coupling Disk Sae 11.5 (Ag318196) Cart Part No 2H.976.22.0.00 , De Flange Sae 3 Rating5 To 12 5 Kva 1Ph 7 5 To 20 Kva 3Phpma046pu002bframekg4 Cart Part No 2H.976.23.0.00 , Nde Flange (Mc),Rating-5 To 12.5 Kva 1Ph,7.5 To 20 Kva 3Ph,(Pma029pu003b),Frame-Kg40 Cart Part No 2H.976.24.0.00 , Terminal Bar,Rating-5 To 12.5 Kva 1Ph,7.5 To 20 Kva 3Ph,(Pla092ai002b),Frame-Kg40 Cart Part No 2H.976.25.0.00 , Cylinder Head Assembly Cart Part No 2H.979.30.0.00 , Valve Rocker Assembly Cart Part No 2H.982.20.0.00 , Cylinder Head Assemblysingle Jacket Cart Part No 2H.983.30.0.00 , 100 Ampcontactor Assembly Cart Part No 2H.999.07.0.Sp , Set Of Joints 2R1040 G1 Cpcb Ii Engine Cart Part No 2H.999.10.0.Sp , Wet Pm Kit (W/O Oil) For 2H.3005, 2H.3010 - 2R1040 Cart Part No 2H.999.11.0.Sp , Wet Pm Kit (W/O Oil) For 2H.8322,2H.8322.Pb,2H.8307-2R1040 G1 Cart Part No 2H.999.14.0.Sp , Thermostat Element 60C Cart Part No 30.182.01.0.00 , Hose Clip Cart Part No 30.650.02.0.00 , Protection Cap Cart Part No 30.735.06.0.00 , Plain Washer For Bearing Cap Cart Part No 34.001.07.0.00 , Nut: Cyl Head Stud M14x1.5 Cart Part No 34.001.18.0.00 , Dome Nut Cart Part No 34.001.19.0.00 , Dowel For Gear Casing Cart Part No 34.001.23.0.00 , Plain Washer Cart Part No 34.001.29.0.00 , Precoated Plugfor Oil Gallery Cart Part No 34.001.35.0.00 , Key For Crank Shaft Cart Part No 34.003.02.0.00 , Crankshaft Plug - Aluminium Cart Part No 34.003.07.0.00 , Washer For Aluplug Cart Part No 34.003.08.0.00 , Crankshaft Gear Cart Part No 34.005.01.0.00 , Crankshaft Gear Cart Part No 34.005.02.0.00 , Intermediate Gear Cart Part No 34.007.20.0.00 , Thrust Plate Cart Part No 34.009.02.0.00 , Valve Tappet Cart Part No 34.010.06.0.00 , Cup For P R Tube Cart Part No 34.011.02.0.00 , Spring For Push Rod Tube Cart Part No 34.011.05.0.00 , Rubber Bush Top Cart Part No 34.011.06.0.00 , Rubber Bush Bottom Cart Part No 34.011.07.0.00 , Oil Sealfwe 100 X 120 X 12Ptfe Cart Part No 34.012.05.0.00 , Oil Seal: Cr Seal Cart Part No 34.012.12.0.00 , Oil Seal: Gear End Cart Part No 34.012.13.0.00 , Valve Seat Insert: Inlet Cart Part No 34.013.03.0.00 , Valve Seat Insert: Exhaust Cart Part No 34.013.04.0.00 , Valve Guide Cart Part No 34.013.05.0.00 , Stud For Rocker Support Cart Part No 34.013.06.0.00 , Stud For Rocker Support Cart Part No 34.013.07.0.00 , Valve Guide Cart Part No 34.013.08.0.00 , Cup For Valve Spring Cart Part No 34.013.13.0.00 , Valve Stem Seal Cart Part No 34.013.19.0.00 , Valve Cart Part No 34.013.70.0.00 , Joint: Fuel Pump Cart Part No 34.016.12.0.00 , Banjo Bolt With Strainer Cart Part No 34.016.15.0.00 , Feed Pump W/O Bowl Filter Cart Part No 34.016.40.0.00 , Leak Off Pipe Cart Part No 34.016.60.0.00 , Fuel Pump Gear Cart Part No 34.017.04.0.00 , Washer For Fuel Pump Gear Cart Part No 34.017.05.0.00 , Lube Oil Pump Assly Cart Part No 34.018.10.0.00 , Jt For L O P Body Cart Part No 34.020.02.0.00 , O Ring : Del Body 2.7X17-21516 Cart Part No 34.020.03.0.00 , Delivery Body Cart Part No 34.020.20.0.00 , Joint: Lube Oil Filter Adaptor Cart Part No 34.021.05.0.00 , Joint For L.O.Filter Adaptor (Sspl-Ss/Ko/1194) Cart Part No 34.021.06.0.00 , Banjo Bolt Cart Part No 34.023.06.0.00 , Piston Pin Cart Part No 34.025.24.0.00 , Dowel For Con Rod Cart Part No 34.026.02.0.00 , Connecting Rod Bolt Cart Part No 34.026.03.0.00 , Relief Valve Assly Cart Part No 34.028.20.0.00 , Banjo Bolt : 10X1 Cart Part No 34.030.05.0.00 , Sealing Ring: Fuel Filter Cart Part No 34.032.01.0.00 , Prefilter Element Cart Part No 34.032.02.0.00 , Fuel Filter Element Cart Part No 34.032.03.0.00 , Fuel Filter Element Cart Part No 34.032.12.0.00 , O F Valve Assly Cart Part No 34.032.60.0.00 , Leak Off Pipe Connection Cart Part No 34.034.05.0.00 , Fuel Pipe 90,14X14 B,260 Wb Cart Part No 34.035.03.0.00 , Perforated Disc Cart Part No 34.036.50.0.00 , Cap Assly Cart Part No 34.036.60.0.00 , Joint: Flange/Fuel Spout Cart Part No 34.040.02.0.00 , Clip For Rain Cap Mounting On Exhaust Silencer Cart Part No 34.042.02.0.00 , Starter Ring Cart Part No 34.043.02.0.00 , Dowel Cart Part No 34.046.02.0.00 , Flywheel Bolt: M14x15x40 Cart Part No 34.046.05.0.00 , Flywheel Bolt: M14x15x45 Cart Part No 34.046.07.0.00 , V Belt A56 Cart Part No 34.053.01.0.00 , Pin For Stopping Cable Cart Part No 34.077.05.0.00 , Diaphragm Cart Part No 34.084.01.0.00 , Joint: Rocker Cover Cart Part No 34.088.02.0.00 , Start/Stop Button 12V/24V40a Cart Part No 34.101.03.0.00 , Joint Ss: Adaptor On Ex Mfold Cart Part No 34.107.06.0.00 , Gasket (For Inlet Air Heater) Cart Part No 34.107.12.0.00 , Fuel Pipe 7.5 14X14 B 700 Wb Cart Part No 34.151.01.0.00 , Clip For Flexible Pipe With Sleeve Cart Part No 34.151.03.0.00 , Fuel Pipe 7.5 14X14 B 700 Pb Cart Part No 34.151.04.0.00 , Clip For Flexible Pipe With Sleeve Cart Part No 34.151.06.0.00 , Fuel Pipe: Wire Braided Cart Part No 34.174.01.0.00 , Lube Oil Temp Gauge Cart Part No 34.183.03.0.00 , Adaptor For Pressure Switch Cart Part No 34.184.01.0.00 , Pressure Switch 0.8 To 1.2 Cart Part No 34.184.02.0.00 , Pin Cart Part No 34.188.05.0.00 , Joint For Blanking Plate Non Asbestos Cart Part No 34.242.11.0.00 , Flexible Pipe: Lop Gauge Cart Part No 34.250.02.0.00 , Flange For 20 Flexible Exhaust Pipe Cart Part No 34.265.03.0.00 , Spacer Cart Part No 34.312.03.0.00 , Intermediate Gear Cart Part No 34.341.10.0.00 , Flywheel Pulling Stud And Bolt Cart Part No 34.950.07.0.00 , Push Rod Kit Cart Part No 34.990.01.0.00 , Oil Seal(Spr.)Indg. Cart Part No 34.999.02.0.00 , Fuel Filter Kit 0.5 Ltr Cart Part No 34.999.15.0.00 , High Pressure Pipe Assembly Cart Part No 35.008.70.0.00 , V Belt A55 Cart Part No 35.047.01.0.00 , Fuel Pipe 8Mm Id 14X14b 2M Long Pb Cart Part No 35.107.01.0.00 , Fuel Pipe: 8.0 14X14 B 2500L Pb Cart Part No 35.107.02.0.00 , Ext Nozzle Leak Off: 4.4 14Bx12u, 2500Pp Cart Part No 35.107.03.0.00 , Starter 12V Cart Part No 36.010.06.0.00 , H P Pipe Setcomplete Bend Rb01 Fwe Cart Part No 36.011.80.0.00 , Fuel Pipe 8.0 14 B 1000 Wb Cart Part No 36.040.01.0.00 , Fuel Pipe Cart Part No 36.040.03.0.Pr , Joint Ring: Liner Cart Part No 38.002.03.0.00 , Joint: Cyl Liner To Block Cart Part No 38.002.06.0.00 , Joint Liner To Head0 25 Mm Cart Part No 38.002.13.0.00 , Tube Cart Part No 38.002.15.0.00 , Sealing Ring: Water Ferrule Cart Part No 38.002.18.0.00 , V Belt B46 Cart Part No 38.006.01.0.00 , Joint: Water Pump Volute Cart Part No 38.009.05.0.00 , Joint: Water Inlet Manifold Cart Part No 38.013.11.0.00 , Joint: Water Outlet Manifold Cart Part No 38.014.11.0.00 , W T Gauge 3.6 Cap 40-100 Cart Part No 38.022.11.0.00 , Water Temp Gauge 1.8M Cart Part No 38.027.02.0.00 , Stud For Gear Casing Cart Part No 38.054.01.0.00 , V Belt: B47 1237 Long Cart Part No 38.066.01.0.00 , Set Of Joints Cart Part No 38.100.10.0.00 , Fuel Pipe: 400Mm Cart Part No 38.156.01.0.00 , Fuel Pipe: 9.0 14X14b 520 Wb Cart Part No 38.156.02.0.00 , Set Of O Rings Cart Part No 38.164.10.0.00 , Hose: Radiator To Pump Cart Part No 38.167.14.0.00 , Hose: Engine To Radiator Cart Part No 38.167.15.0.00 , Valve Guide Cart Part No 38.181.02.0.00 , Valve Seat Insert Exhaust Cart Part No 38.181.03.0.00 , Valve Pair Cart Part No 38.181.70.0.00 , Lube Oil Filter Assly Cart Part No 38.195.20.0.00 , Cylinder Head Bolt: Short Cart Part No 38.196.02.0.00 , Cyl Head Stud: Long Cart Part No 38.196.03.0.00 , Gasket: Cylinder Head 1.2Mm Thk Cart Part No 38.197.05.0.00 , Cyl Head Steel Gasket 0.80 Mm Thk Cart Part No 38.197.06.0.00 , Cyl Head Steel Gasket 1.0Mm Thk Cart Part No 38.197.07.0.00 , Cyl Head Steel Gasket 1.2 Mm Thk Cart Part No 38.197.08.0.00 , Cyl Liner Assembly Cart Part No 38.197.10.0.00 , Piston Ring Set Cart Part No 38.198.30.0.00 , Piston Assembly Cart Part No 38.198.90.0.00 , Push Rod Tube Assembly Cart Part No 38.201.10.0.00 , Water Pump Assembly Cart Part No 38.207.40.0.00 , Fuel Filter With Sealing Wire Cart Part No 38.226.03.0.00 , Leak Off Pipe Sub Assly Cart Part No 38.258.10.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 38.260.01.0.00 , Hose: Radiator To Water Pipe Cart Part No 38.260.03.0.00 , Hose: Water Outlet Manifold To Radiator Cart Part No 38.260.04.0.00 , Aluminium Radiator For Rv2 Cpcb Engines Cart Part No 38.260.90.0.00 , Cogged V Belt: B X47 Cart Part No 38.359.01.0.00 , Anti Vibration Mounts Cart Part No 38.394.01.0.00 , Wet Pm Kit (W/O Oil) For 38.1325, 39.1302- Rv3 G-Drive Cart Part No 38.999.77.0.Sp , Fuel Pipe: 7.5 14X14b 320 Wb) Cart Part No 39.027.22.0.00 , Ball Joint Assy Cart Part No 39.032.10.0.00 , Thermostat Element 74? Cart Part No 39.040.09.0.00 , Fuel Connectionfor M14 Banjo Bolt Cart Part No 39.092.10.0.00 , Set Of Joints For Swaraj 735 Tractor Cart Part No 39.130.10.0.00 , Hose: Radiator Cart Part No 39.169.02.0.00 , Water Pump Assly With Pulleyrv 3 Std Cart Part No 39.170.10.0.00 , Set Of Joints Cart Part No 39.173.10.0.00 , Set Of High Pressure Pipes Cart Part No 39.179.10.0.00 , Crankcase (Lh) Assembly Cart Part No 39.185.20.0.00 , Set Of Joints Cart Part No 39.220.10.0.00 , Joint For Lub Oil Sumpc Isump Cart Part No 39.224.02.0.00 , Water Pump Assly: 120 Pcd Cart Part No 39.230.10.0.00 , Hose: Water Pipe To Tee Connection Cart Part No 39.231.01.0.00 , Hose: Radiator To Water Pipe Cart Part No 39.231.03.0.00 , Leak Off Pipe Sub Assly Cart Part No 39.236.10.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 39.237.02.0.00 , Combined Leak Off Pipe Cart Part No 39.238.10.0.00 , Drain Pipe: Lube Oil Sump Cart Part No 39.240.01.0.00 , Wet Pm Kit (W/O Oil) For - 39.3001 - Rv3 Cart Part No 39.300.01.0.Sp , Fip Nut Cart Part No 39.405.03.0.00 , Wiring Harness Engine To Control Panel Cart Part No 39.901.10.0.00 , Wiring Harness Assly: Eng To Control Cart Part No 39.902.10.0.00 , Wet Pm Kit (W/O Oil) For 39.1335 - Rv3 G Drive Cart Part No 39.999.03.0.Sp , Wet Pm Kit (W/O Oil) For 39.3005… 39.3004... Rv3( Al. Radiator) Cart Part No 39.999.33.0.Sp , Stud(For Front Axle Support) Cart Part No 3H.001.02.0.00 , Crankcase Assembly Cart Part No 3H.001.60.0.00 , Cam Shaft & Gear Assembly Cart Part No 3H.003.10.0.00 , Subassly Of Egr Camshaft For 3R1040ta / Tc Cpcb Ii Cart Part No 3H.003.30.0.00 , Fuel Injection Pump Cart Part No 3H.004.20.0.00 , Lube Oil Pump Assly. Cart Part No 3H.005.10.0.00 , Sub Assly Lo Pump Int Gear & Bush Cart Part No 3H.005.30.0.00 , Assly For Internal Gear Cart Part No 3H.005.60.0.00 , Lube Oil Pump Cart Part No 3H.005.70.0.00 , Suction Tube Cart Part No 3H.006.20.0.00 , Header: Lube Oil Cooler -Filter Cart Part No 3H.007.01.0.00 , Joint: Header Cart Part No 3H.007.02.0.00 , Adaptor For Spin On Filter Cart Part No 3H.007.05.0.00 , Lube Oil Cooler & Header Assly Cart Part No 3H.007.10.0.00 , Lube Oil Cooler (3 Plate) Cart Part No 3H.007.11.0.00 , Joint: Lube Oil Cooler Non Asbestos Cart Part No 3H.007.13.0.00 , Joint: Header Cart Part No 3H.007.15.0.00 , Header For Lub Oil Cooler Spin On Remote Filter Cart Part No 3H.007.18.0.Pr , Lube Oil Cooler Cart Part No 3H.007.19.0.00 , Lub Oil Cooler Header Assly Cart Part No 3H.007.30.0.00 , Cyl Head Gasket 1.22 Mm Thk Cart Part No 3H.009.06.0.00 , O Ring: Nozzle Cart Part No 3H.009.11.0.00 , Cylhead With Core Plugs Cart Part No 3H.009.30.0.00 , Oil Metering Orifice (Dia 8) Cart Part No 3H.010.06.0.00 , Valve Rocker Assembly Cart Part No 3H.010.10.0.00 , High Pressure Pipe Assembly Cart Part No 3H.011.10.0.00 , Leak Off Pipe Assly Cart Part No 3H.012.20.0.00 , Inlet Manifold Cart Part No 3H.013.03.0.Pr , Gasket For Air Inlet Manifold Cart Part No 3H.013.04.0.Pr , Joint: Rocker Cover Cart Part No 3H.014.11.0.00 , Joint For Rocker Cover Cart Part No 3H.014.13.0.00 , Inlet Manifold Cart Part No 3H.015.01.0.00 , Joint: Air Inlet Mfold Cart Part No 3H.015.11.0.00 , Adapter For Exhaust Silencer Cart Part No 3H.016.02.0.00 , Exhaust Manifold Cart Part No 3H.016.04.0.00 , Oil Supply Pipefor Fuel Pump Cart Part No 3H.016.08.0.00 , 50 Hrs - A Check Maintenance Kit Cart Part No 3H.019.11.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 3H.019.13.0.Sp , Flywheel Assembly (S/F Ace Tractor) Cart Part No 3H.021.20.0.Pr , Dipstick Assembly Cart Part No 3H.024.10.0.00 , Breather Pipe Cart Part No 3H.028.01.0.00 , Breather Pipe Cart Part No 3H.028.06.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 3H.029.02.0.00 , Lower Clamp(For Radiator Pipe) Cart Part No 3H.029.03.0.00 , Top Clamp(For Radiator Pipe) Cart Part No 3H.029.04.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 3H.029.05.0.00 , Hose For Thermostat To Radiator Cart Part No 3H.029.08.0.00 , Clip For Hose Cart Part No 3H.029.17.0.00 , Gasket (Rocker Cover) Cart Part No 3H.032.04.0.Pr , Rubber Hose : Air Cleaner Cart Part No 3H.034.04.0.00 , Valve Rocker Lever (Assy Complete) Cart Part No 3H.034.30.0.Pr , Front Cover Cart Part No 3H.039.01.0.00 , Cover Plate For Front Cover Compressor Mounting Cart Part No 3H.039.04.0.00 , Joint: Cover Plate Cart Part No 3H.039.05.0.00 , H Ppipefor Cyl1 Cart Part No 3H.040.10.0.Pr , Hppipefor Cyl2 Cart Part No 3H.040.20.0.Pr , Hppipefor Cyl3 Cart Part No 3H.040.30.0.Pr , Hppipepump To Rail Cart Part No 3H.040.40.0.Pr , Hppipepump To Rail Cart Part No 3H.040.50.0.Pr , Pulley: Alternator 68 Pcd Cart Part No 3H.041.02.0.00 , Pulley: Alternator 68 Pcd Spz Cart Part No 3H.041.04.0.00 , Oil Filling Body 57 Mm Height Cart Part No 3H.042.01.0.00 , Joint: Oil Filling Body Cart Part No 3H.042.03.0.00 , Joint: Adaptor Cart Part No 3H.043.03.0.00 , Flywheel Sub Assly. Cart Part No 3H.054.10.0.00 , Cross Member Forradiator Support Cart Part No 3H.057.03.0.00 , Thermostat Assembly Cart Part No 3H.061.10.0.00 , Lub Oil Sumpsheet Metal Cart Part No 3H.064.07.0.Pr , Assembly Dipstick Fabricated Oil Sump Cart Part No 3H.064.30.0.Pr , Set Of Copper Washer Cart Part No 3H.074.10.0.00 , Set Of Joints Cart Part No 3H.074.20.0.Sp , Crank Case Foot ( Starter Side) Cart Part No 3H.079.03.0.00 , Crank Case Foot F W Efuel Pump Side Cart Part No 3H.079.04.0.00 , Dipstick Assembly Cart Part No 3H.082.20.0.00 , Flywheel Housing Cart Part No 3H.085.01.0.00 , Flywheel Housing Cart Part No 3H.085.03.0.00 , Uego Sensor For Gas Engines Cart Part No 3H.086.53.0.Pr , Flywheel Assembly Cart Part No 3H.088.10.0.00 , Adaptor (For Crank Case) Cart Part No 3H.096.04.0.Pr , Crankcase Assly With Mb Cap Cart Part No 3H.096.10.0.Pr , Crankcase Assly With Mb Cap Cart Part No 3H.096.40.0.Pr , Crankshaft Assly With Gear Cart Part No 3H.099.10.0.00 , Fuel Pump F002 A0z 776For 3R1040na49 5Hp 2200 Rpm Cart Part No 3H.1007.01.0.00 , Fip (Plain Element) For 3R1040tc_42Hp@1500Rpm For Cpcbii Cart Part No 3H.1007.04.0.00 , Fuel Injection Pump Cart Part No 3H.1007.05.0.00 , Fip: 3R1040_45Hp@2000Rpm Cart Part No 3H.1007.06.0.00 , Turbocharger Cart Part No 3H.1008.01.0.00 , Turbocharger Cart Part No 3H.1008.04.0.00 , High Pressure Pipe Assembly Cart Part No 3H.1009.60.0.00 , Bracket For Relay Box Mtg Cart Part No 3H.1017.02.0.Pr , Egr Cooler 3 Kw Cart Part No 3H.1018.01.0.Pr , Engine Wiring Harness For 3Rta Crdi Cpcb4engine Cart Part No 3H.1043.10.0.Pr , Engine Wiring Harness For 3Rta 40Kva Crdi Cpcb4engine Cart Part No 3H.1043.50.0.Pr , Oil Supply Pipe (For Turbocharger) Cart Part No 3H.1051.10.0.Pr , Cac Cold Pipe Cart Part No 3H.1053.03.0.00 , Piston Assembly Cart Part No 3H.106.30.0.00 , Piston Assembly Complete Cart Part No 3H.106.60.0.00 , Compressor: Sc160 Cart Part No 3H.107.02.0.00 , Adaptor: Compressor Cart Part No 3H.107.03.0.00 , C Type Stop Lever Cart Part No 3H.113.01.0.00 , Reducing End Cart Part No 3H.113.02.0.00 , Screw Plug Cart Part No 3H.113.03.0.00 , Washer Cart Part No 3H.113.04.0.00 , Gear Casing Cart Part No 3H.115.03.0.00 , Adaptor Plate Cart Part No 3H.120.01.0.00 , Gear Cart Part No 3H.120.02.0.00 , Joint: Adaptor Plate Cart Part No 3H.120.03.0.00 , Digital Rpm Meter Hourmeter Cart Part No 3H.130.01.0.00 , Magnetic Pick Up M16x15 Threading Length 60 Mm Cart Part No 3H.130.03.0.00 , Digital Rpm Meter Hourmeter Cart Part No 3H.130.05.0.00 , Fuel Filter Element Primary Cart Part No 3H.132.01.0.00 , Fuel Filter Element Secondary Cart Part No 3H.132.02.0.00 , Sealing Ring (Fuel Filter) Cart Part No 3H.132.03.0.00 , Spinon Fuel Filter 0.6L Tbowl Cart Part No 3H.132.10.0.00 , Water Jacket Heater Kim Hot Type Tps152gt12 000240V Ac 1500W With 120 140F Ther Cart Part No 3H.133.11.0.00 , Stop Solenoid Assly Cart Part No 3H.135.10.0.00 , Water Connection Cart Part No 3H.136.11.0.00 , Water Connection 0.75- 14 Nptf Threads Cart Part No 3H.136.12.0.00 , Adaptor: Oil Sump Male Both Side Cart Part No 3H.147.03.0.00 , Adaptor: Oil Sump Male Benjo Type Cart Part No 3H.147.04.0.00 , Adaptor: Lube Oil Sump Cart Part No 3H.147.07.0.00 , Adaptor: Lube Oil Drain Cart Part No 3H.147.09.0.00 , Injector Cart Part No 3H.148.01.0.00 , Banjo Bolt Cart Part No 3H.148.53.0.00 , Nozzle Leak Off Pipe:Kva20/25 Cart Part No 3H.151.10.0.00 , Radiator Drain Pipe Cart Part No 3H.153.01.0.00 , Adaptor: Drain Cock Cart Part No 3H.153.02.0.00 , Plug For Drain Cock Cart Part No 3H.153.08.0.00 , Radiator Drain Pipe For 82.5 Kva Internaco Project Cart Part No 3H.153.09.0.00 , Drain Cock Cart Part No 3H.153.11.0.00 , Adaptor With Hose Tail Cart Part No 3H.153.12.0.00 , Adaptor With Hose Tail Cart Part No 3H.153.14.0.00 , Drain Cock Cart Part No 3H.153.21.0.00 , Strip Clamp Cart Part No 3H.160.01.0.00 , Fuel Injection Pump: 3R1040pg Cart Part No 3H.171.10.0.00 , Inlet & Outlet Connection Cart Part No 3H.173.04.0.00 , Breather For Fuel Tank Cart Part No 3H.173.05.0.00 , Leak Off Pipe Assembly Cart Part No 3H.175.10.0.00 , Fuel Inlet Pipe: 20-25Kva 750Mm Long Cart Part No 3H.181.01.0.00 , Fuel Return Pipe Cart Part No 3H.181.02.0.00 , Fuel Pipereturn M12x1 5 Male Plug X M16x1 5Union550mm Lengthfor 10 To 125 Kva Cart Part No 3H.181.03.0.00 , Fuel Pipeinlet M12 1 5Mai Plugm16 1 5 Union For 10 To 125 Kva Trailer Mounted550 Cart Part No 3H.181.04.0.00 , Fuel Pipe Return M12x15 Male Plug X M16x15union Cart Part No 3H.181.05.0.00 , Fuel Pipe Return M12x1.5 Male Plug & M16x1.5 Union Nut 900Mm Long Cart Part No 3H.181.13.0.00 , Fuel Pipe Return: M12 Male Plug 14 Union Nut: 400Mm Long Cart Part No 3H.183.16.0.00 , Fuel Pipe Return With M12 Male Plug14 Union Nut250mm Long Cart Part No 3H.183.17.0.00 , Fuel Pipe Return With M14 X 15 Male Plug & ,M14 X 15 Union Nut 250Mm Cart Part No 3H.183.21.0.00 , Fuel Pipe Return With M14 X 1 5 Male Plugm14 X 1 5 Union Nut400mm Long Cart Part No 3H.183.24.0.00 , Fuel Return Pipe M14x1 5 Male Plugm16x1 5 Union Nut Cart Part No 3H.183.25.0.Pr , Fuel Inlet Pipe Metailic Pre-Filter To Tank Cart Part No 3H.183.27.0.Pr , Fuel Pipe Return With M14 Male Plug M16 Union Nut Cart Part No 3H.183.33.0.Pr , Fuel Return Pipem22x1 5 Male Plug M22x1 5 Union Nut Cart Part No 3H.183.37.0.Pr , Air Inlet Manifold For Shanti (Aluminium) Cart Part No 3H.185.01.0.00 , Rocker Cover Cart Part No 3H.190.10.0.00 , Rocker Cover Cart Part No 3H.190.30.0.00 , Fuel Filter Mounting Bracket Spin On Type Cart Part No 3H.191.01.0.00 , Header For L.O. Cooler & Filter S/F Water Jacket Heating Cart Part No 3H.192.01.0.00 , Battery Cable 35Sqmm Cart Part No 3H.208.40.0.Pr , Cold Start Kit Assembly For L3 Level Application 12V System3r Cart Part No 3H.211.70.0.Pr , Hose-Thermostat To Radiator Cart Part No 3H.217.04.0.00 , Drain Pipe For Lub Oil Sump For 6R1080t,6R1080tawith Length 640Mm Cart Part No 3H.219.03.0.00 , Dial Type Mechanical Fuel Level Gauge (105Mm) Cart Part No 3H.219.05.0.00 , Expansion Bellow: 3R Vave Genset 290Mm Cart Part No 3H.223.05.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 3H.241.03.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 3H.241.04.0.00 , Injector Leak Off Pipe 3R1190 Cpcb4 Cart Part No 3H.246.11.0.Pr , Fuel Pipe I/L - M16x1.5 Union Cart Part No 3H.280.01.0.00 , Pipe (From Radiator Outlet To Water Pump Inlet) Cart Part No 3H.282.01.0.00 , Hose From Water Pump In To Radiator Out Cart Part No 3H.282.04.0.00 , Pipefrom Radiator Outlet To Water Pump Inlet Cart Part No 3H.282.05.0.00 , Spout For Fuel Filling Cart Part No 3H.283.05.0.00 , Fuel Pipe (Feed Pump To Filter) Cart Part No 3H.289.03.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 3H.289.07.0.00 , Fuel Pipe Feed Pump To Tank Unit Cart Part No 3H.289.14.0.00 , Fuel Pipe (Feed Pump To Tank Unit) Cart Part No 3H.289.15.0.00 , Fuel Pipefeed Pump To Tank Unit Cart Part No 3H.289.21.0.Pr , Hose: Thermostat To Radiator Cart Part No 3H.291.01.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 3H.291.02.0.00 , Bracket For Stay Cart Part No 3H.291.03.0.00 , Stay For Radiator Cart Part No 3H.291.04.0.00 , Hose: Make Up Connection Cart Part No 3H.291.07.0.00 , Hose: Make Up Connection Cart Part No 3H.291.09.0.00 , Aluminium Radiator: 3R Cart Part No 3H.291.10.0.00 , Hose From Water Pump In To Radiator Outlet Cart Part No 3H.291.101.0.Pr , Hosethermostat To Radiator Cart Part No 3H.291.102.0.Pr , Hose: Radiator To Pump Inlet Cart Part No 3H.291.18.0.00 , Breather Hose Cart Part No 3H.291.29.0.00 , Hose For Make Up Connection Cart Part No 3H.291.32.0.00 , Hosethermostat To Radiator Cart Part No 3H.291.37.0.Pr , Pipe - Thermostat To Rad In. Cart Part No 3H.291.41.0.00 , Hose: Thermostat Outlet To Radiator In Cart Part No 3H.291.42.0.00 , Hose- Metallic Pipe To Radiator In. Cart Part No 3H.291.43.0.00 , Hose - Radiator To Pump In Pipe Cart Part No 3H.291.44.0.00 , Hose: Make Up Connection Cart Part No 3H.291.46.0.00 , Pipe Thermostat To Radiator In Cart Part No 3H.291.47.0.Pr , Pipe From Radiator To Pump Inlet Cart Part No 3H.291.48.0.Pr , Aluminium Radiator Assly: 3R1040 Cart Part No 3H.291.90.0.00 , Aluminium Radiator Assembly For 3R1040 Cpcb Engines Cart Part No 3H.291.94.0.00 , Aluminium Radiator Assembly Cart Part No 3H.291.95.0.Pr , Aluminium Radiator Assembly Cart Part No 3H.291.96.0.Pr , Leak Off Pipe Cart Part No 3H.292.01.0.00 , Leak Off Pipe Cart Part No 3H.292.02.0.00 , Clamp Cart Part No 3H.292.05.0.Pr , Crankshaft Assembly Cart Part No 3H.299.10.0.00 , Crankshaft Assly Without Gear Cart Part No 3H.299.20.0.00 , Wet Pm Kit (W/O Oil) 3H.3001, 3H.3012 - 3R1040 Cart Part No 3H.300.1.0.Sp , Bracket For Fuel Filter Mounting Cart Part No 3H.301.01.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 3H.301.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No 3H.301.03.0.00 , Charging Alternator 12V, 35A Cart Part No 3H.315.01.0.00 , Charging Alternator 35A13 5V Regulator With Battery Sensing Cart Part No 3H.315.03.0.Pr , Stud Coupler 70Mm Cart Part No 3H.328.11.0.00 , Lube Oil Drain H& Pump Assembly Cart Part No 3H.345.10.0.00 , 125A, 4Pole Mccb, Model: Lv516312, Mak Cart Part No 3H.352.14.0.Pr , Rad Water Fill Cap With Rubber Seal For Canopy Cart Part No 3H.408.31.0.00 , Ceramic Wool 64 Density Cart Part No 3H.408.54.0.00 , Flame-Proof High Density Foam 70 Density, Cart Part No 3H.408.88.0.00 , Ss Lh Hinge For Canopy Cart Part No 3H.408.90.0.00 , Ss Rh Hinge For Canopy Cart Part No 3H.408.91.0.00 , Hose: Air Cleaner Cart Part No 3H.415.06.0.00 , Pvc Pipe For Air Cleaner Cart Part No 3H.415.07.0.00 , Air Cleaner Assly: 4.5M3 Cart Part No 3H.415.10.0.00 , Hose For Air Cleaner With Restriction Indicator Port Cart Part No 3H.415.22.0.00 , Hose For Pvc Pipe Cart Part No 3H.415.23.0.00 , Pvc Pipe For Air Cleaner Cart Part No 3H.415.24.0.00 , Air Cleaner Assembly Cart Part No 3H.415.25.0.00 , Primary Element Cart Part No 3H.415.46.0.00 , Avm Cylindricalh 30 X Dia 30 X M8radiator 40 45 Sh Cart Part No 3H.432.03.0.Pr , Control Panel Schematic For 45Kva3ph With Kg645 Ip A Cart Part No 3H.465.40.0.Pr , Control Panel Schematic For 45Kva 3Ph 3Rta With Kg645 Ip B Cart Part No 3H.465.50.0.Pr , Control Panel Schematic For 45Kva3ph With Kg640 Ip A Cart Part No 3H.465.70.0.Pr , Control Panel 25 30 Kva For 3Rt 3Ph With Kg640ip B Cart Part No 3H.470.80.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No 3H.488.02.0.Pr , Fuel Pipe (Pre Filter To Tank Unit) Cart Part No 3H.488.03.0.Pr , Fuel Pipe Return With M14 X 1.5 Male Plug & ,M14 X 1.5 Union Nut Cart Part No 3H.488.04.0.Pr , Air Cleaner Hose Cart Part No 3H.488.06.0.Pr , Hose For Pvc Pipe Cart Part No 3H.488.07.0.Pr , Exhaust Pipe (Doc Outlet To Bellow) Cart Part No 3H.488.12.0.Pr , U Clamp For Doc Cart Part No 3H.488.14.0.Pr , Clamping Plate For Doc Cart Part No 3H.488.16.0.Pr , Fuel Pipepre Filter To Tank Unit Cart Part No 3H.488.33.0.Pr , Air Cleaner Hose To Turbo Cart Part No 3H.488.34.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No 3H.488.43.0.Pr , Hosethermostat To Radiator Cart Part No 3H.488.44.0.Pr , Crankcase Assembly Cart Part No 3H.501.20.0.00 , Special Banjo Bolt Assemblyfor Oil Spray Nozzle Cart Part No 3H.501.30.0.00 , Oil Spray Nozzle Assly Cart Part No 3H.501.40.0.00 , Inlet Manifold Cart Part No 3H.502.01.0.00 , Inlet Manifold Cart Part No 3H.502.03.0.00 , Exhaust Manifold Cart Part No 3H.503.01.0.00 , Hose: Turbocharger Cart Part No 3H.504.03.0.00 , Air Pipe Cart Part No 3H.504.05.0.00 , Lube Oil Supply Pipe Cart Part No 3H.505.01.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 3H.505.02.0.00 , Air Pipe (Turbo Side) Cart Part No 3H.506.02.0.00 , Bracketfor Air Pipe Cart Part No 3H.506.05.0.00 , Joint For Air Pipe Cart Part No 3H.506.06.0.00 , Air Pipe (Cac Side) Cart Part No 3H.506.08.0.00 , Air Pipe (Cac To Inlet Manifold) Cart Part No 3H.506.11.0.00 , Air Pipe (Turbo Side) Cart Part No 3H.506.17.0.00 , Cac Hose (Hot Side 4 Plies) Cart Part No 3H.506.18.0.00 , Cac Hosecold Side Cart Part No 3H.506.19.0.00 , Exhaust Diffuser Cart Part No 3H.518.01.0.00 , Bracket For Diffuser Cart Part No 3H.518.02.0.00 , Valve Rocker Assembly Cart Part No 3H.519.20.0.00 , Adaptor On Inlet Manifold Cart Part No 3H.520.01.0.00 , Cps Module Cart Part No 3H.577.01.0.00 , 1 Pin Connectorf350 Seriesmssl Tt Amp Uvs Cart Part No 3H.577.05.0.Sp , Engine Wiring Harness Assembly Cart Part No 3H.577.20.0.00 , Engine Wiring Harness Assembly Cart Part No 3H.577.80.0.00 , Cold Start Wiring Harness Sf Flange Heater Cart Part No 3H.578.100.0.00 , Engine Wiring Harness Assembly Cart Part No 3H.578.40.0.00 , Engine Wiring Harness With Cps 4-20Ma Gems Sensor Cart Part No 3H.578.50.0.00 , Engine Wiring Harness With Cps 3R 45 Kva Cart Part No 3H.578.60.0.00 , Engine Wiring Harness Assembly Cart Part No 3H.579.20.0.00 , Engine Wiring Harness Sf 3R Engine Cart Part No 3H.580.10.0.00 , Engine Wiring Harness 30Kva 3R Cart Part No 3H.580.20.0.Pr , Temp Sensor Pigtail Cart Part No 3H.580.40.0.Pr , Selector Switch 3Way With Off5 Pole Cart Part No 3H.581.56.0.Pr , Selector Switch 6A 3Way With Off4 Pole Cart Part No 3H.581.57.0.00 , Selector Switch 6A 2Way With Off2 Pole Cart Part No 3H.581.58.0.00 , Engine Wiring Harness With Cps 3R Sf Kg934 Cart Part No 3H.584.10.0.00 , Engine Wiring Harness For 3Rt 30Kva Emerald Cart Part No 3H.584.40.0.Pr , Mcb, 2Pole, 2 Amps Cart Part No 3H.5960.33.0.00 , Engine Wiring Harness For 3Rta 30Kva Crdi Cpcb4engine Cart Part No 3H.6257.40.0.Pr , Exhaust Doc Pipe Benddoc Out To Bellow In Cart Part No 3H.768.03.0.Pr , Silencer Assembly Cart Part No 3H.792.40.0.Pr , Terminal Block Assembly- 25-40 Kva 1 Phase Cart Part No 3H.816.01.0.Asp , Sae 3,De Brkt- Prot. Screen Asly - Kg32 Cart Part No 3H.816.03.0.Asp , Excitor Rotor With Rra Kg32 M L H 55 6Pkva Rating30 401Ph Cart Part No 3H.816.05.0.Asp , Koel Green Alternatorkg30 S T Framem Ecp28a Vl 4Sae 3 11 5 415V50 Hz0 8 Pf Cart Part No 3H.816.23.0.Pr , Wet Pm Kit (W/O Oil) For 3H.8322 Cart Part No 3H.832.2.0.Sp , Relay Board-12Vdc Therm Elect Cart Part No 3H.853.01.0.00 , 12V Control Panel Assembly For Ff Pumpset With Male Connector Cart Part No 3H.853.10.0.00 , Control Panel 24V Fighting Cart Part No 3H.854.10.0.00 , Mcb: 32A Sp Cart Part No 3H.864.04.0.00 , Mcb Single Pole 6Amp - A9n1p06c Cart Part No 3H.864.09.0.00 , Amf Panel Dwg Of 3R 30Kva 3Ph For Reliance Infratel Cart Part No 3H.864.40.0.Pr , Glass Fuse 20 Mm Length 4 Amp Cart Part No 3H.870.08.0.00 , Battery Charger : 4A 24 Vdc Cart Part No 3H.870.15.0.00 , Mcb 50A 3Pole Cart Part No 3H.894.07.0.00 , Koel Green Alternatorkg 25 S T Framel Kg 42 3 Bsae 3 11 5 415V50 Hz0 8 Pf Cart Part No 3H.901.01.0.Pr , Koel Green Alternatorkg 25 S S Framel Kg 42 3 Fsae 3 11 5 230V50 Hz0 8 Pf Cart Part No 3H.901.02.0.Pr , Koel Green Alternatorkg35 S S Framel Kg 42 3 Jsae 3 11 5 230V50 Hz0 8 Pf Cart Part No 3H.901.04.0.Pr , Koel Green Alternatorkg35 S T Framel Kg 42 3 Esae 3 11 5 415V50 Hz0 8 Pf Cart Part No 3H.901.05.0.Pr , Clip 25 Dia For Flexible Pipe Cart Part No 3H.905.02.0.00 , Clip 20 Dia For Flexible Pipe Cart Part No 3H.905.04.0.00 , Rubber Sleeve For Tempswitch Cart Part No 3H.905.05.0.00 , Tie Wrap 200 Mm Length Cart Part No 3H.905.07.0.00 , Rubber Sleeve 16 Dia Cart Part No 3H.905.15.0.00 , Rubber Sleeve 27 Dia Cart Part No 3H.905.16.0.00 , P-Clip Cart Part No 3H.905.18.0.Pr , Wiring Harness With Connector For Switches Cart Part No 3H.913.10.0.00 , Wiring Harness For Ff Pumpset Allication Cart Part No 3H.922.10.0.00 , Hosethermostat To Radiator Cart Part No 3H.9457.25.0.Pr , Hose Radiator To Pump In Pipe Cart Part No 3H.9457.27.0.Pr , Gear Casining Cart Part No 3H.962.01.0.00 , Camshaft Assly Cart Part No 3H.968.20.0.Pr , Cylinder Head Gasket Cart Part No 3H.969.02.0.Pr , Cyl Head With Valve Guide Valve Seat Insert Cart Part No 3H.969.20.0.Pr , Cylinder Head Assembly Cart Part No 3H.971.30.0.00 , Bracket For Fuel Filter Cart Part No 3H.972.02.0.00 , Kit For Replacement Of Interface Card From 3H.982.31 And 3H.982.32 To 3H.989.12 Cart Part No 3H.989.11.0.Sp , Dc Interface Card Cart Part No 3H.989.12.0.00 , Engine Wiring Harness Cart Part No 3H.990.10.0.Pr , Connecting Rod Assyw O Bearing Cart Part No 3H.991.10.0.00 , Leak Off Pipe Cpcb, M12u Cart Part No 3H.992.01.0.Pr , Bracket For Doc Mounting Cart Part No 3H.995.01.0.Pr , Doc_3R1190_Na Cart Part No 3H.995.04.0.Pr , Conrod Bearing Set For 3H 9801Engine Cart Part No 3H.999.08.0.Sp , Set Of Joints Cart Part No 3H.999.10.0.Sp , Wet Pm Kit (W/O Oil) For 3H.8422,3H.8422.Pb,3H.8423,3H.8407,3H.8408,3H.8409,3H.8411,3H.84 Cart Part No 3H.999.15.0.Sp , Wet Pm Kit (W/O Oil ) For 3H.8902 Cart Part No 3H.999.19.0.Sp , Wet Pm Kit (W/O Oil) For 3H.3025, 3H.3030, 3H.3031, 3H.8301,3H.8403, 3H.8503, 3H.8506, 3H.90 Cart Part No 3H.999.20.0.Sp , Wet Pm Kit (W/O Oil ) For 3H.8951 Cart Part No 3H.999.21.0.Sp , Wet Pm Kit (W/O Oil) For 3H.3017 - 3R1040 ( Cpcb ) Cart Part No 3H.999.84.0.Sp , Crankshaft Pulley Cart Part No 3H.M001.01.0.00 , Hose Thermstat To He Inlet Cart Part No 3H.M412.03.0.00 , Hose Pipe: Inlet Manifold Cart Part No 40.002.06.0.00 , Hose: Water Outlet Manifold Cart Part No 40.003.02.0.00 , Spacer For Fan (15 Mm) Cart Part No 40.054.03.0.00 , V Belt: B48 1262 Long Cart Part No 40.123.01.0.00 , O Ring: Cyinder Liner -21507 Cart Part No 42.003.02.0.00 , Cyl Liner Assembly Cart Part No 42.003.20.0.00 , Sealing Bush: Cyl Hd Stud Cart Part No 42.004.19.0.00 , Valve Seat Insert Exh Cart Part No 42.004.21.0.00 , O Ring: P R Ferrule 2.7X18 - 21509 Cart Part No 42.004.22.0.00 , Jointcyl Liner To Head 0 40Mm Thick Cart Part No 42.004.23.0.00 , Ferrule Tube Cart Part No 42.004.26.0.00 , Sealing Ring Cart Part No 42.004.28.0.00 , Valve Pair Cart Part No 42.004.70.0.00 , Sleeve: Nozzle Holder Cart Part No 42.005.05.0.00 , Piston Pin Cart Part No 42.008.02.0.00 , Piston Ring Set Std Rb00 Cart Part No 42.008.72.0.00 , Joint: Cyl Head To Exh Manifold Cart Part No 42.014.02.0.00 , Joint: Cyl Head To Air Inlet Manifold Cart Part No 42.014.03.0.00 , Exhaust Silencer Cart Part No 42.066.02.0.00 , Starting H&Le Cart Part No 42.091.30.0.00 , Adaptor: 23Mm Cart Part No 42.102.01.0.00 , Sump Drain Pipe: 700Mm Benjo On Both Side Cart Part No 42.107.01.0.00 , Water Separator Cart Part No 43.075.10.0.00 , Mud Collector - Filter Cart Part No 43.075.20.0.00 , Anti Vibration Mounts Cart Part No 44.035.05.0.00 , Leak Off Pipe Cart Part No 45.052.01.0.00 , Hose Cart Part No 45.106.05.0.00 , Cyl Liner Assembly Cart Part No 46.005.10.0.00 , Push Rod Cart Part No 46.008.20.0.00 , Set Of Jointsrb22 Rb00 Cart Part No 46.039.10.0.00 , Set Of Copper Washer Cart Part No 46.039.30.0.00 , Flexible Pipe: 1 Mt Long Cart Part No 46.048.01.0.00 , Electric Water Temp Gauge 12V Cart Part No 46.065.02.0.00 , Electric Water Temp Gauge 40-120 Degc24v Cart Part No 46.066.02.0.00 , Collet Pair Cart Part No 46.072.04.0.00 , Joint: Cyl Head 1.00 Cart Part No 46.072.22.0.00 , Steel Joint:Cyl Head 1.2Mm Cart Part No 46.072.23.0.00 , Steel Joint:Cyl Head 1.4Mm Cart Part No 46.072.24.0.00 , Steel Joint:Cyl Head 1.6Mm Cart Part No 46.072.25.0.00 , Joint: Cyl Head 1.1Mm Th Cart Part No 46.072.26.0.00 , Cyl Head Joint:1.3Mm Cart Part No 46.072.27.0.00 , Steel Joint:Cyl Head 1.5Mm Cart Part No 46.072.28.0.00 , Lube Oil Temp Gauge Elect:40-150/160 D Cart Part No 46.084.01.0.00 , Lube Oil Temp Gauge Ele:40-150/160 D Cart Part No 46.085.01.0.00 , Sensor Unit: Elec Temp Gauge Cart Part No 46.085.02.0.00 , Adaptor For Exhaust Silencer Cart Part No 46.148.01.0.00 , Elec Hour Meter 12V Cart Part No 46.177.01.0.00 , Electronic Hour Meterr 24V Cart Part No 46.178.01.0.00 , Magnetic Pickup Cart Part No 46.179.05.0.00 , Valve Pair Cart Part No 46.188.70.0.00 , Lube Oil Press Gauge 0-10 Kg/Sqcm Cart Part No 46.244.01.0.00 , Electrical Lube Oil Press Gauge 0-10Bar Cart Part No 46.250.01.0.00 , Lube Oil Press Gauge Electrical:0-10 Bar 24V Cart Part No 46.251.01.0.00 , Rubber Sleeve 38X10 For Pr Gauge Sensor Cart Part No 46.252.02.0.00 , Lube Oil Pressure Sensor With Switch Three Point Dual Wiper Type Cart Part No 46.252.05.0.00 , Wiring Harness For Elec Pr Gauge Sendor Cart Part No 46.252.20.0.00 , Wiring Harness For Lube Oil Pressure Cart Part No 46.252.40.0.00 , Hour Meter Digital Cart Part No 46.253.02.0.Pr , Silensor Clamp Cart Part No 46.256.05.0.00 , Rubber Block 0.12 Rb Coupling Cart Part No 46.349.04.0.00 , Inner Member0 12 Rb Coupling Cart Part No 46.349.05.0.00 , Coupling: 0.12 Rb Cart Part No 46.349.10.9.00 , Set Of Copper Washer Cart Part No 46.353.08.0.00 , Expansion Bellow Assly: 2.5 Cart Part No 46.357.10.0.00 , Sleeve For Exhaust Silencer 55 2 Dia Cart Part No 46.367.03.0.00 , Water Pump With Spindle Brg Cart Part No 46.388.03.0.00 , Alternator: 12V 35A Cart Part No 46.390.01.0.00 , Push Rod Kit Cart Part No 46.999.01.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 47.002.02.0.00 , Joint Bet Cr Case & Block (0.80 Mm Thick Cart Part No 47.014.02.0.00 , Joint: Cyl Block 0.80 Mm Thk Cart Part No 47.014.08.0.00 , Copper Shim Cart Part No 47.014.09.0.00 , Copper Shim: 0.50 Mm Cart Part No 47.014.11.0.00 , Thermostat Cover-Horizontal Outlet Pointing Towards Rights Side Viewing Tow Cart Part No 47.025.03.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 47.027.01.0.00 , Joint: Brg Housing Water Pump Cart Part No 47.033.02.0.00 , Lube Oil Filter Assly Cart Part No 47.035.10.0.00 , Set Of Joints Cart Part No 47.045.10.0.00 , Set Of O Rings: Rb33-Rb00 Cart Part No 47.045.20.0.00 , Set Of Copper Washer Cart Part No 47.045.30.0.00 , Spacer For Fan Cart Part No 47.051.01.0.00 , Set Of Joints Cart Part No 47.094.10.0.00 , Set Of O Ringsfor Swaraj 855 Tractor Cart Part No 47.094.20.0.00 , Set Of Copper Washer Cart Part No 47.094.30.0.00 , Primary Filter Element Cart Part No 47.113.04.0.00 , Safety Filter Element Cart Part No 47.113.05.0.00 , Restriction Indicator -20Wg Cart Part No 47.113.15.0.00 , Restriction Indicator 47.113.15.0. Wit Cart Part No 47.113.18.0.Pr , Radiator Fan: Rr Engine 15 Pusher Cart Part No 47.127.01.0.00 , Rubber Bush: Top Cart Part No 47.204.04.0.00 , Joint For Cooler Cover Plate Cart Part No 47.212.04.0.00 , Sealed Water Saparator Assembly Cart Part No 47.277.10.0.00 , Water Separator Cart Part No 47.278.01.0.00 , Water Separator Cart Part No 47.278.05.0.00 , Gear Casing Gasket Cart Part No 47.297.04.0.00 , Wet Pm Kit (W/O Oil) For 47.3001 - Rb33 Cart Part No 47.300.01.0.Sp , Wet Pm Kit (W/O Oil) For 46.3001,46.3004,46.3006,46.4004 - Rb22 Cart Part No 47.300.1.0.Sp , Wet Pm Kit (W/O Oil) For 47.3013,47.3027,47.3037,47.9017,47.9027 - Rb33 Cart Part No 47.301.3.0.Sp , V Belt Cogged (Bx-48) Cart Part No 47.305.01.0.00 , Bearing For Hydraulic Gear Cart Part No 47.307.05.0.00 , Drive Shaft Assembly Cart Part No 47.307.20.0.00 , V Belt Bx52 Cog Cart Part No 47.329.02.0.00 , Cap Assembly Cart Part No 47.383.30.0.00 , Hose: Water Pipe To Adaptor Cart Part No 47.387.01.0.00 , Hose: Radiator To Water Pipe Cart Part No 47.387.03.0.00 , Hose: Radiator To Thermostat Cart Part No 47.387.07.0.00 , Hose (Thermostat To Radiator) Cart Part No 47.491.01.0.00 , Hose: Radiator To Pump Inlet Cart Part No 47.491.04.0.00 , Make-Up Hose Cart Part No 47.491.05.0.00 , Makeup Hose: Rb33 Cart Part No 47.491.09.0.00 , Aluminium Radiator: Rb33 Cart Part No 47.491.90.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 47.492.01.0.00 , Piston Assembly Cart Part No 47.507.20.0.00 , Expansion Bellow Cart Part No 47.512.10.0.00 , Joint: Gear Casing Cart Part No 47.515.02.0.00 , Leak Off Pipe Sub Assly Cart Part No 47.531.10.0.00 , Piston Assembly Cart Part No 47.533.10.0.00 , Piston Ring Set Cart Part No 47.533.30.0.00 , Joint For Rocker Cover Cart Part No 47.541.02.0.00 , Stepless Ear Clamp Cart Part No 47.542.02.0.00 , 50 Am. Terminal(Male) Type-280075-2 Cart Part No 47.569.12.0.00 , Oetiker Clamp Id361 Cart Part No 47.601.01.0.00 , Oetiker Clamp With 565 Id Cart Part No 47.601.08.0.00 , Push Rod Kit Cart Part No 47.990.01.0.00 , Wet Pm Kit (W/O Oil) For 47.1523 - Rb33 Cart Part No 47.999.11.0.Sp , Wet Pm Kit (W/O Oil) For 47.3024 - Rb33 Cart Part No 47.999.12.0.Sp , Wet Pm Kit (W/O Oil) For 47.3021 - Rb33 Sr Ii Cart Part No 47.999.27.0.Sp , Wet Pm Kit (W/O Oil) For 38.3001- Rb33 Sr Ii Cart Part No 47.999.34.0.Sp , Wet Pm Kit (W/O Oil) For 47.3008, 47.3012 - Rb33 Plus Cart Part No 47.999.62.0.Sp , Hose: Thermostat To Radiator 160Lg Cart Part No 48.019.02.0.00 , Hose Cart Part No 48.019.06.0.00 , Adaptor : Water Pump Cart Part No 48.019.07.0.00 , Joint: Water Pump Adopter Cart Part No 48.019.08.0.00 , Clamp For Raised Dip Stick Guide Cart Part No 48.032.07.0.00 , Set Of Jointsrb44 Rb00 Cart Part No 48.039.10.0.00 , Set Of Copper Washer Cart Part No 48.039.30.0.00 , Dowel Bolt: Alternator -M10x130lg Cart Part No 48.067.03.0.00 , Bush For Alternator 32Mm Cart Part No 48.067.04.0.00 , Leak Off Pipe 1000 Mm Long Cart Part No 48.112.01.0.00 , Plate For Fuel Filter Cart Part No 48.113.01.0.00 , Overhaul Kit Rb44 Jcb Cart Part No 48.115.30.0.00 , O Ring Cart Part No 48.117.03.0.00 , Fuel Filter Element Pre Cart Part No 48.117.04.0.00 , Fuel Filter Element Micro Cart Part No 48.117.05.0.00 , Fuel Filter 1.1 L Twin Bowl Cart Part No 48.117.10.0.00 , L.O.P.G.Pipe - 2 Mtr Long Cart Part No 48.121.01.0.00 , Sealing Ring: Push Rod Tube Cart Part No 48.122.01.0.00 , Fuel Pipe Cart Part No 48.129.01.0.00 , Outer Element Cart Part No 48.145.02.0.00 , Inner Element Cart Part No 48.145.03.0.00 , Air Cleaner Assly: Dry Type Cart Part No 48.145.10.0.00 , Sealing Ring For Water Ferrule Cart Part No 48.155.04.0.00 , Set Of Joint Cart Part No 48.156.10.0.00 , Set Of O Rings Cart Part No 48.156.20.0.00 , Set Of Copper Washer Cart Part No 48.156.30.0.00 , Joint: Bearing Housing Cart Part No 48.173.08.0.00 , Fuel Pipe-9.5,14X14b,450R Cart Part No 48.188.01.0.00 , Radiator Fan 17Dia-Pusher Cart Part No 48.212.01.0.00 , Anti Vibrn Mtg: Bottom Radiator Cart Part No 48.213.08.0.00 , Radiator Cap: 7Psi Sealed Cart Part No 48.213.15.0.00 , Thermostat Bypass Hose Cart Part No 48.214.04.0.00 , Rubber Hose Cart Part No 48.215.04.0.00 , Pre Cleaner Assly Cart Part No 48.215.10.0.00 , Flex Pipe -Engine To Cooler Cart Part No 48.231.03.0.00 , Plug For Dip Stick Hole Cart Part No 48.288.02.0.00 , Jupiter Worm Drive Clamp,Type 603,65Mm Dia(S/F 65Mm Hose O.D.) Cart Part No 48.305.06.0.00 , Worm Drive Hose Clamp 80Mm Cart Part No 48.305.07.0.00 , Hose Clamp: 110Mm Dia Cart Part No 48.305.08.0.00 , Silencer Assly Cart Part No 48.318.10.0.00 , Sucker Fan 494 Dia Metallic Cart Part No 48.338.02.0.00 , Holder For Inner Cable Cart Part No 48.340.02.0.00 , Fuel Pipe: M14xm14-1800 Length Cart Part No 48.406.01.0.00 , Spacer For Support Bracket Cart Part No 48.414.01.0.00 , Lube Oil Supply Hose: Fip Cart Part No 48.417.01.0.00 , Alternator: 24V 40A Cart Part No 48.436.01.0.00 , Actuator Cart Part No 48.503.01.0.00 , Fuel Filter Kit 1.1 Ltr Cart Part No 48.999.20.0.00 , Set Of Joints Cart Part No 49.079.10.0.00 , Set Of O Rings: Rb66-Rb00 Cart Part No 49.079.20.0.00 , Set Of Copper Washer Cart Part No 49.079.30.0.00 , Radiator Fan: 494 Dia Pusher Cart Part No 49.080.01.0.00 , Worm Drive Hose Clip Cart Part No 49.097.01.0.00 , Worm Drive Hose Clip Cart Part No 49.097.07.0.00 , Hose Clip Size No 1 28X30 Cart Part No 49.097.08.0.00 , Nut: Ss M8 Cart Part No 49.106.02.0.00 , Exhaust Silencer Cart Part No 49.114.01.0.00 , O Ring: Element Header Cart Part No 49.117.06.0.00 , Fan: 20 Pusher Cart Part No 49.119.01.0.00 , Joint: Turbo Inlet Cart Part No 49.120.04.0.00 , Joint: Inlet Pipe Cart Part No 49.121.03.0.00 , Joint: Drain Pipe Cart Part No 49.121.05.0.00 , Off/On/Start Switch 1160A Cart Part No 49.135.03.0.00 , Low Oil Pres Switch 1.7Kg/Cmsq Cart Part No 49.156.01.0.00 , Bracket For Rpm Meter (Fitted On Body) Cart Part No 49.162.01.0.00 , V Belt: Bx51 Raw Edge Cogged Cart Part No 49.202.01.0.00 , Air Inlet Cap Cart Part No 49.403.03.0.00 , Coupling 0.24 Rb Cart Part No 49.438.10.9.00 , Rubber Block 0.2 Rb Coupling Cart Part No 49.462.04.0.00 , Coupling: 0.20 Rb Cart Part No 49.462.10.9.00 , Hose(For Drain Pipe) Cart Part No 49.472.08.0.00 , Piston Assembly Cart Part No 49.480.10.0.00 , Piston Ring Set (3Ring) Cart Part No 49.480.30.0.00 , Relay For Stop Solenoid Cart Part No 49.626.05.0.00 , Engine Safety Unit: Krb101 Cart Part No 49.902.02.0.00 , Blanking Plate For Cam Bore Cart Part No 4H.001.03.0.00 , Sealing Cap Cart Part No 4H.001.05.0.00 , Hollow Dowel (16 Dia) Cart Part No 4H.001.13.0.00 , Joint: Cam Bore Blanking Plate Cart Part No 4H.001.14.0.00 , Precoated Plug Cart Part No 4H.001.22.0.00 , Monoblock Ccase W/O Bearing Cart Part No 4H.001.70.0.00 , Crankshaft Gear Cart Part No 4H.002.01.0.00 , Crankshaft Gear Assly Cart Part No 4H.002.20.0.00 , Crankshaft Assly. With Gear Cart Part No 4H.002.60.0.00 , Thrust Washer - Cam Shaft Cart Part No 4H.003.02.0.00 , Camshaft Sub Assly Cart Part No 4H.003.20.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.003.70.0.00 , Camshaft Gear Assembly Cart Part No 4H.003.80.0.00 , Lo Supply Hose Fip M10 Banjo X 235 Cart Part No 4H.006.01.0.00 , Delivery Valve Cart Part No 4H.006.04.0.00 , Fuel Pump: 9 Mm Lift Vsc Cart Part No 4H.006.10.0.00 , Lub Oil Supply Pipe, Crankcase To Fuel Pump, 210 L Cart Part No 4H.006.13.0.00 , Valve Guide Cart Part No 4H.007.02.0.00 , Valve Seat Insert-Inlet Cart Part No 4H.007.03.0.00 , Valve Seat Insert-Exhaust Cart Part No 4H.007.04.0.00 , Bolt For Cylinder Head. Cart Part No 4H.007.07.0.00 , Button For Injector Yoke Cart Part No 4H.007.08.0.00 , Gasket: Cylinder Head 1.10 Thk Cart Part No 4H.007.11.0.00 , Cyl Head Gasket 1.22 Mm Thk Cart Part No 4H.007.24.0.00 , Valve Seat Insertinlet Semi Finish Cart Part No 4H.007.39.9.00 , Valve Pair Inlet & Exhaust Cart Part No 4H.007.40.0.00 , Cylinder Head Reconditioning Kit 4R1040 Engines (Pg & Indl Bsii) Cart Part No 4H.007.55.0.00 , Valve Rocker Assly Cart Part No 4H.008.10.0.00 , Rocker Shaft Sub Assly Cart Part No 4H.008.20.0.00 , Rocker Cover Joint Metalic Cart Part No 4H.009.12.0.00 , Gasket (For Rocker Cover) Cart Part No 4H.009.15.0.00 , Leak Off Pipe Assly Cart Part No 4H.010.23.0.00 , Leak Off Pipe Assembly Cart Part No 4H.010.29.0.00 , Auto Timer Cart Part No 4H.012.01.0.00 , Fuel Pump Gear Cart Part No 4H.012.02.0.00 , Bolt Assly.(Autotimer) Cart Part No 4H.012.20.0.00 , Suction Tube Assly Cart Part No 4H.015.10.0.00 , Hydraulic Pump Gear Cart Part No 4H.016.01.0.00 , Crank Pulley: Finish Cart Part No 4H.019.01.0.00 , Mud Slinger Cart Part No 4H.019.93.0.00 , Spacer For Mud Slinger Cart Part No 4H.019.94.0.00 , Spacer For Fan Ejcb 3Dx Cart Part No 4H.020.02.0.00 , Spacer: Fan Cart Part No 4H.020.03.0.00 , Radiator Fan: Ejcb Cart Part No 4H.020.91.0.00 , Joint: Delivery Volute Cart Part No 4H.021.03.0.00 , Water Pump Pulley: 120Pcd Spa Section Cart Part No 4H.021.08.0.00 , Water Pump Assly 345 Crs Cart Part No 4H.021.20.0.00 , Water Pump Assly Wo Del Vol 345Crs Cart Part No 4H.021.30.0.00 , Joint: Water Outlet Manifold Cart Part No 4H.022.11.0.00 , Thermostat Bypass Hose Cart Part No 4H.023.02.0.00 , Bypass Hose: 58Mm Long Cart Part No 4H.023.03.0.00 , Thermostat Bypass Hose Cart Part No 4H.023.06.0.Pr , Vacuator Valve Cart Part No 4H.024.03.0.00 , Primary Filter Element Cart Part No 4H.024.12.0.00 , Safety Filter Element Cart Part No 4H.024.13.0.00 , Air Cleaner Assly Cart Part No 4H.024.70.0.00 , Set Of High Press Pipe: 530X1.5 Id Cart Part No 4H.025.10.0.00 , Oil Filling Body Sub Assly Cart Part No 4H.027.10.0.00 , Joint: Oil Filling Body Cart Part No 4H.027.11.0.00 , Exhaust Manifold (End Opening) Cart Part No 4H.028.01.0.00 , Hose: Dry Type Air Cleaner Cart Part No 4H.029.02.0.00 , T Bolt Clamp, Klipco Tb 88 /Jupitor ( 92 To 100 Dia ) Cart Part No 4H.029.05.0.00 , T Bolt Clamp Tb78: 84 Cart Part No 4H.029.06.0.00 , Air Inlet Manifold Cart Part No 4H.030.01.0.00 , Mettalic Joint: Inlet Manifold Cart Part No 4H.030.06.0.00 , Joint: Air Inlet Manifold Cart Part No 4H.030.11.0.00 , Bracket For Fuel Filter Cart Part No 4H.031.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.031.04.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 4H.031.05.0.00 , Clamp Cart Part No 4H.031.06.0.00 , Rubber Sleeve Cart Part No 4H.031.07.0.00 , Clamp Assembly Without Rubber Sleeve Cart Part No 4H.031.30.0.00 , Lifting Hook Cart Part No 4H.033.01.0.00 , Engine Lifting Hook Cart Part No 4H.033.03.0.00 , Dipstick Assly Cart Part No 4H.034.10.0.00 , Gasket: Exh Manifold Cart Part No 4H.035.02.0.00 , Gasket: Exh Adaptor S.S. Cart Part No 4H.035.03.0.00 , Plastic Cover For Exhaust Manifold Opening Cart Part No 4H.035.05.0.00 , Exhaust Mfold Ge Top Open Cart Part No 4H.035.07.0.00 , Adaptor: Exhaust Silencer Cart Part No 4H.036.01.0.00 , Flywheel Housing Cart Part No 4H.038.01.0.00 , Flange: Starter 13- 6Mm Eff Cart Part No 4H.038.02.0.00 , Blanking Plate For Flywheel Housing Cart Part No 4H.038.04.0.00 , Water Inlet Connection 38 Core Cart Part No 4H.039.01.0.00 , Joint: W.I Conn & Therm Hsg Cart Part No 4H.039.02.0.00 , Thermostat Housing Cart Part No 4H.040.01.0.00 , Gear End Foot(Fuel Pump Side) Cart Part No 4H.042.05.0.00 , Gear End Foot(Alternator Side) Cart Part No 4H.042.06.0.00 , Pulley: Alternator 90 Pcd Cart Part No 4H.044.01.0.00 , Pulley Alternator ( 84.3 Pcd, S/F Ecel - 6H.2117) Cart Part No 4H.044.05.0.00 , Mounting Subassembly For Alternator Cart Part No 4H.044.20.0.00 , V Belt Cart Part No 4H.046.01.0.00 , V Belt Raw Edged Cogged Cart Part No 4H.046.02.0.00 , Flywheel Housing Cart Part No 4H.047.11.0.00 , Adaptor Sae 3 To Sae 4 For Ltk Cart Part No 4H.047.12.0.00 , Hp Pipe Complete Set 700 Mm Cart Part No 4H.050.60.0.00 , High Pressure Pipe Assembly Cart Part No 4H.050.70.0.00 , Joing: Bearing Housing Cart Part No 4H.052.11.0.00 , Joint: Delivery Volute Cart Part No 4H.052.12.0.00 , Water Pump Assly With Del Vol 282.5 Crs Cart Part No 4H.052.20.0.00 , Water Pump Assembly (Higher Bearing Size) Cart Part No 4H.052.95.0.00 , Thermostat Housing M14 Tap Both Sides Cart Part No 4H.053.01.0.00 , Thermostat Cover(Pg - 116 Height) Cart Part No 4H.053.02.0.00 , Thermostat Housing Cart Part No 4H.053.04.0.00 , Joint: Thermostat Cover Cart Part No 4H.053.08.0.00 , Thermostat Housing Assly(Pg) Cart Part No 4H.053.10.0.00 , Joint: Thermostat Housing Cart Part No 4H.053.11.0.00 , Joint: Thermostat Cover Cart Part No 4H.053.12.0.00 , Assembly Thermostat Housing Cart Part No 4H.053.50.0.00 , Thermostat Housing Assemblyboth M14top Cover Towards Fip Cart Part No 4H.053.60.0.00 , Adaptor M10x15 For Lop Guage Cart Part No 4H.057.08.0.00 , Crankcase Foot Cart Part No 4H.061.01.0.00 , Crankcase Foot Cart Part No 4H.061.02.0.00 , Flywheel End Footfor Ltk Cart Part No 4H.061.13.0.00 , Flywheel End Footfor Ltk Cart Part No 4H.061.14.0.00 , Suction Tube Cart Part No 4H.064.10.0.00 , Suction Tube Assly.(Sheet Metal Sump) Cart Part No 4H.064.20.0.00 , Starter Bracket: Pg Cart Part No 4H.065.02.0.00 , Bracket Starter Cart Part No 4H.065.03.0.00 , V Belt: Xpa 1250 Cogged Cart Part No 4H.069.01.0.00 , Belt: Spax 1300 Cogged Cart Part No 4H.069.02.0.00 , Hose: Radiator To Waterpump 45X45x130l Cart Part No 4H.073.01.0.00 , Hose: Pipe To Water Pump 45X45x80l Cart Part No 4H.073.02.0.00 , Pipe: Radiator To Water Pump Inlet Cart Part No 4H.073.03.0.00 , Upper Clamp For Pipe Cart Part No 4H.073.04.0.00 , Lower Clamp For Pipe Cart Part No 4H.073.05.0.00 , Pipe(Radiator To Pump Inlet) Cart Part No 4H.073.07.0.00 , Hose: Thermostat To Radiator Cart Part No 4H.073.08.0.00 , Metalic Breather Hose Cart Part No 4H.073.16.0.00 , Hose Water Pump Inlet To Radiator Outlet Cart Part No 4H.073.36.0.Pr , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 4H.077.02.0.00 , Fuel Pipe ( Fuel Filter To Fuel Pump ) Cart Part No 4H.077.03.0.00 , Radiator Support Starter Side Cart Part No 4H.081.01.0.00 , Radiator Support Fuel Pump Side Cart Part No 4H.081.02.0.00 , Cross Member Forradiator Support Cart Part No 4H.081.03.0.00 , Lube Oil Sump: 3Cx Cart Part No 4H.085.01.0.00 , Set Of Joints (Turbo Pg Engine) Cart Part No 4H.087.05.0.Sp , Set Of Joints Cart Part No 4H.087.10.0.Sp , Set Of O Rings Cart Part No 4H.087.20.0.00 , Set Of Copper Washers Cart Part No 4H.087.30.0.00 , Set Of Joints Cart Part No 4H.087.40.0.Sp , Set Of O Rings For Pg: 4H.3031 Cart Part No 4H.087.50.0.00 , Set Of Copper Washer 4H.3031 Cart Part No 4H.087.60.0.00 , Set Of Joint: 4R Tc/Ta Bsiii Application Engines Cart Part No 4H.087.96.0.Sp , Set Of Joint: 4R Tc/Ta Bsiii Application Engines Cart Part No 4H.087.97.0.Sp , Accelerator Lever Pull Type (37 Mm) Cart Part No 4H.088.01.0.00 , Accelerator Lever Pull Type (27 Mm) Cart Part No 4H.088.02.0.00 , Pull Type Accelerator Lever Cart Part No 4H.088.03.0.00 , Bracket For Mounting Accelerator & Stop Cable Cart Part No 4H.088.04.0.00 , Stop Lever Cart Part No 4H.089.01.0.00 , Thermostat Cover Cart Part No 4H.096.03.0.00 , Thermostat & Housing Cart Part No 4H.096.10.0.00 , Thermostat And Mounting (M14 Adapator On Both End ) Cart Part No 4H.096.40.0.00 , Radiator Cart Part No 4H.1005.20.0.00 , Aluminium Radiator Assly Cart Part No 4H.1005.60.0.00 , Rocker Cover Cart Part No 4H.1009.90.0.00 , Dipstick Assly: 290Mm Cart Part No 4H.1027.10.0.00 , Dipstick Assembly Cart Part No 4H.1027.20.0.00 , Rocker Cover Cart Part No 4H.1028.10.0.00 , Gear Casing Cart Part No 4H.1034.01.0.00 , Gear Casing Cart Part No 4H.1034.02.0.00 , Engine Wiring Harness For 4K Crdi Cpcb 4+ Cart Part No 4H.1043.10.0.Pr , Engine Wiring Harness For 4K 125Kva Cpcb4+ Engine Cart Part No 4H.1043.20.0.Pr , Engine Wiring Harness For 4K 125Kva Cpcb Iv Cart Part No 4H.1043.80.0.Pr , Flywheel L T8 10Dp St Ring Cart Part No 4H.1044.10.0.00 , Engine Wiring Harness For 4R 82.5Kva Cpcb4+ Cart Part No 4H.1045.30.0.Pr , Engine Wiring Harness For 4R 82.5Kva Cpcb4+ Cart Part No 4H.1045.40.0.Pr , Dipstick Assembly Complete 350 Mm, S.F.35 Deg Sump Cart Part No 4H.1047.10.0.00 , Hose Cart Part No 4H.1048.02.0.00 , Turbocharger For 4Rta 1800 Rpm Engine (K24 2460 Gga 6.11) Cart Part No 4H.1050.10.0.00 , 120 Ohm1/4 Watt Mfr Type Resistance Cart Part No 4H.1062.11.0.00 , Spacer: Ext Manifold Cart Part No 4H.107.02.0.00 , Primary Filter Element Assly Cart Part No 4H.1086.01.0.00 , Safety Filter Element Cart Part No 4H.1086.02.0.00 , Air Cleaner Assly: Radial Seal Cart Part No 4H.1086.10.0.00 , Locating Bolt 80 Mm : Eye Bolt Cart Part No 4H.1089.01.0.00 , Locating Bolt 60Mm Cart Part No 4H.1089.02.0.00 , Bracket: Stay Rod Cart Part No 4H.1091.05.0.00 , Driven Hub For Compressor Cart Part No 4H.1093.01.0.00 , Housing For Compressor Drive Arrangement Cart Part No 4H.1093.02.0.00 , Driving Hub For Compressor Cart Part No 4H.1093.03.0.00 , Spider Coupling (For Compressor Drive) Cart Part No 4H.1093.04.0.00 , Joint Gear Casing Side Cart Part No 4H.1093.06.0.00 , Gear For Compressor Driving Cart Part No 4H.1093.07.0.00 , Deep Groove Ball Bearing Both Side Sealed (55 X 90) Cart Part No 4H.1093.08.0.00 , Leak Off For Fip Cart Part No 4H.1097.21.0.Pr , Leaf Off For Rail And Fip For 4K Cart Part No 4H.1097.22.0.Pr , Leak Off For Injector Cart Part No 4H.1097.23.0.00 , Fuel Pipefeed Pump To Fuel Filter Cart Part No 4H.1097.31.0.00 , Fuel Pipefuel Filter To Fip Cart Part No 4H.1097.32.0.00 , Front Cover (Hydraulic Pump Gear Bore) Cart Part No 4H.1098.01.0.00 , Cover (Hydraulic Pump Gear Bore) Cart Part No 4H.1098.02.0.00 , Joint: Cover Plate Cart Part No 4H.1098.03.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.1120.10.0.00 , Piston Assembly Complete(Gas Engine) Cart Part No 4H.1122.10.0.00 , Lube Oil Sump Cart Part No 4H.1128.01.0.00 , Spacer For Radiator Fan (35 Mm) Cart Part No 4H.1141.01.0.00 , Dipstick Assly: S/F Fab Sump Cart Part No 4H.1143.10.0.00 , Dipstick Assly Cart Part No 4H.1143.20.0.00 , Flywheel Assembly Cart Part No 4H.1171.10.0.00 , Flywheel Assembly Cart Part No 4H.1171.30.0.00 , Flywheel Assly Cart Part No 4H.1171.60.0.00 , Flywheel Assembly Cart Part No 4H.1171.85.0.Pr , Piston Ring Set 105 Dia Cart Part No 4H.1172.30.0.00 , Piston Assembly Cart Part No 4H.1172.70.0.00 , Gear Casing Cart Part No 4H.1174.01.0.00 , Gear Casing Cart Part No 4H.1174.02.0.00 , Gear Casing Cart Part No 4H.1174.04.0.00 , Gear Casing (For 4K / 6K Engine) Cart Part No 4H.1174.11.0.00 , Exhaust Mfold Cen Up Open Cart Part No 4H.1176.01.0.00 , Crankcase With Mb/Caps (Line Bore Operation) Cart Part No 4H.1179.40.0.00 , Flywheel Housing Cart Part No 4H.1180.01.0.00 , Flywheel Housing Cart Part No 4H.1183.01.0.00 , Flywheel Housingsae 3 Cart Part No 4H.1183.06.0.Pr , Alternator: 12V 65A Cart Part No 4H.1188.01.0.00 , Cover For Fuel Pump Bore Cart Part No 4H.1190.02.0.00 , Joint For Fuel Pump Gear Cover Cart Part No 4H.1190.03.0.00 , Condenser Diode & Varistor-45/62.5Kva-1 Phase Cart Part No 4H.1196.01.0.Asp , Terminal Block Assembly- 45-62.5 Kva 1 Phase Cart Part No 4H.1196.02.0.Asp , Koel Green Alternatorkg82 5 S T Framel Kg 443 Bsae 3 11 5 415V50 Hz0 8 Pf Cart Part No 4H.1196.12.0.Pr , Koel Green Alternatorcoastalhumid Environmentkg82 5 S T Framekg 44 3 B2 Cart Part No 4H.1196.17.0.Pr , Primary Element For 6M3 Air Cleaner (2990217219) Cart Part No 4H.1198.01.0.00 , Safety Element For 6M3 Air Cleaner (2990217223) Cart Part No 4H.1198.02.0.00 , Air Cleaner: Dry Typ 6 P92 Cart Part No 4H.1198.10.0.00 , Hose: Radiator To Thermostat Cart Part No 4H.1205.01.0.00 , Push Rod Cart Part No 4H.1205.02.0.00 , Hose: Makeup Water Connection Cart Part No 4H.1205.03.0.00 , Aluminium Radiator Assly: 4R1040 Cart Part No 4H.1205.90.0.00 , Radiator With 17 Fan Cart Part No 4H.1205.92.0.00 , Water Pump Assly 282.5 W/O Pulley Cart Part No 4H.1210.10.0.00 , Hose For Brather Pipe 4Rt Cart Part No 4H.1216.02.0.00 , Bracket For Speed Adjustment Cart Part No 4H.122.01.0.00 , Bar For Speed Adjustment Cart Part No 4H.122.02.0.00 , Hose: Air Cleaner Cart Part No 4H.1221.02.0.00 , Rubber Hoseturbo Toair Cleaner Cart Part No 4H.1221.04.0.00 , Engine Mtg. Foot (Fip Side) Cart Part No 4H.1223.03.0.00 , Engine Mtg. Foot ( Starter Side) Cart Part No 4H.1223.04.0.00 , Mounting Plate For Fuel Filter Cart Part No 4H.1228.01.0.00 , Emergency Stop Pbwith N0 Element Hormony Rangerelease Mushroom Type Xb5 Cart Part No 4H.1234.09.0.00 , Cover For Camshaft Bore On Gear Casing Cart Part No 4H.1235.02.0.00 , Gear Casing Joint Cart Part No 4H.1235.03.0.00 , Cover Joint Cart Part No 4H.1235.05.0.00 , Timing Pointer Cart Part No 4H.1235.06.0.00 , Gear Casing Cart Part No 4H.1235.08.0.00 , Mud Slinger Cart Part No 4H.1235.12.0.00 , Joint For Gear Casing Cart Part No 4H.1235.13.0.00 , Gear Casing Cart Part No 4H.1235.17.0.00 , Lube Oil Sump Cart Part No 4H.1247.01.0.00 , Thermostat Hosuing Assembly Cart Part No 4H.125.60.0.00 , Adaptor For Fan Cart Part No 4H.1253.02.0.00 , Fule Pipe - Fule Pump To Fuel Filter (475 Hose Length) Cart Part No 4H.1266.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.1266.02.0.00 , Current Transfarmor 100/5, 5 Va Cart Part No 4H.1268.05.0.00 , Poly V Beltsect 4Pk 1255 Cart Part No 4H.1269.01.0.00 , Flywheel Assembly Cart Part No 4H.1274.10.0.00 , Front Cover Cart Part No 4H.1284.05.0.00 , Cover For Fuel Pump Gear Cart Part No 4H.1284.07.0.00 , Fuel Pump Gear Cart Part No 4H.1284.09.0.00 , Hub For Fuel Pump Gear Cart Part No 4H.1284.11.0.00 , Adaptor For Fuel Tank Breather With M12 X 1.5 Both Side Cart Part No 4H.1285.04.0.00 , Lub. Oil Sump Drain Pipe S/F New Lub. Oil Hand Pump Cart Part No 4H.1285.07.0.00 , Bush For Avm Locking Cart Part No 4H.1285.43.0.00 , Breather Hose Pipe Cart Part No 4H.1285.88.0.Pr , Flywheel Housing Cart Part No 4H.1288.01.0.00 , Exhaust Mfold: K26 Turbocharger Cart Part No 4H.129.02.0.00 , Hexagonal Socket Head Cap Screw (Copper Coated) Cart Part No 4H.129.03.0.00 , Mud Slinger S/F 4H.1295.01 Crank Pulley Cart Part No 4H.1295.02.0.00 , Pulley: Crank 4R1040 Jcb Eng Cart Part No 4H.1295.11.0.00 , Crankshaft Pulley S/F Gear Casing (6Pk 143 Pcd) Cart Part No 4H.1295.14.0.00 , Crankshaft Pulley ( 172P.C.D. Spa, 1Gr ) Cart Part No 4H.1295.21.0.00 , Pulley: Alternator 68 Pcd Cart Part No 4H.1296.01.0.00 , Water Pump Pulley: 120Pcd Cart Part No 4H.1297.01.0.00 , Alternator Pulley: 90 Pcd A Sec Cart Part No 4H.1298.01.0.00 , Exhaust Diffuser Cart Part No 4H.130.03.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.130.04.0.00 , Swivel Adaptor Cart Part No 4H.130.05.0.00 , Adaptor Ring On K26 Turbocharger Cart Part No 4H.130.06.0.00 , Joint Ss: Adaptor Ring Cart Part No 4H.130.07.0.00 , Oil Metering Orifice Cart Part No 4H.1301.04.0.00 , Crankcase Without Bearings Cart Part No 4H.1301.10.0.00 , Crankcase Assly With Mb Cap (4K1080 4V) (4H.1301.110.0.Pr) Cart Part No 4H.1301.110.0.Sp , Crankcase Assly With Mb Cap4k1080 4V Cart Part No 4H.1301.220.0.Sp , Crankcasemonoblockwith Sealing Cap Cart Part No 4H.1301.60.0.00 , Piston Cooling Nozzle Cart Part No 4H.1301.90.0.00 , Crankshaft Assly Cart Part No 4H.1302.10.0.00 , Fuel Pump 4R1040tc 105 Hp 2200 Rpm Cart Part No 4H.1308.02.0.00 , Fuel Pump 4R1040tc 110 Hp 2500 Rpmf 002 Aoz 638 Cart Part No 4H.1308.03.0.00 , Fuel Pump 4R1040tc Cart Part No 4H.1308.04.0.00 , Fuel Pump 4R1040tc 96 Hp @ 2200 Rpm Cart Part No 4H.1308.06.0.00 , Turbocharger: K24 Cart Part No 4H.1308.09.0.00 , Fuel Injection Pump For 4R1040t Engine105hp 2200Rpm Cart Part No 4H.1308.16.0.Pr , Air Delivery Pipe Cart Part No 4H.131.01.0.00 , Sleeve Cart Part No 4H.131.02.0.00 , Bracket For Air Delivery Pipe Cart Part No 4H.131.03.0.00 , Heat Shield Cart Part No 4H.131.04.0.00 , Hose: Radiator Inlet Cart Part No 4H.1318.01.0.00 , Injector S-Type (5X0.284X150x13 , 950 Htf; Nha No. E043 2252 00) Cart Part No 4H.1319.01.0.00 , Injector Cart Part No 4H.1319.03.0.00 , Adaptor: Turbocharger Side Cart Part No 4H.132.02.0.00 , Adaptor: Crankcase Side Cart Part No 4H.132.04.0.00 , Lube Oil Inlet Pipe: K24 Turbo Cart Part No 4H.132.21.0.00 , Lube Oil Drain Pipe: K24 Turbo Cart Part No 4H.132.23.0.00 , Joint: Adaptor Turbo Side Cart Part No 4H.132.27.0.00 , Joint: Adaptor Ccase Side Cart Part No 4H.132.28.0.00 , Joint: Lube Oil Drain Pipe Cart Part No 4H.132.29.0.00 , Joint: Adaptor Ccase Side Cart Part No 4H.132.31.0.00 , Adaptorfor Turbo Drain ( Crankcase Side ) Cart Part No 4H.132.32.0.00 , Nozzle Leak Off Pipe Cart Part No 4H.1321.01.0.00 , Leak Off Pipe Assembly Cart Part No 4H.1321.02.0.Pr , Leak Off Pipe Assly Cart Part No 4H.1323.20.0.00 , Leak Off Pipe Assly: 4R1050ta Cpcb Cart Part No 4H.1323.30.0.00 , V Belt: Xpa 1345 Raw Edged Cogged Cart Part No 4H.133.02.0.00 , V Belt Spax 1332 Cart Part No 4H.133.03.0.00 , Koel Green Alternatorkg 62 5 S T Framel Kg 42 3 Ksae 3 11 5 415V50 Hz0 8 Pf Cart Part No 4H.1331.07.0.00 , Koel Green Alternatorcoastal Humid Environment Kg 62 5 S T Framekg 42 3 K Cart Part No 4H.1331.08.0.Pr , 58.5Kva 1Ph ,230V, Alternator With Special Cart Part No 4H.1331.25.0.Pr , Spacer 30 Mm For Fan Mounting Cart Part No 4H.1333.01.0.00 , Rubber Hose (Heat Exchanger To Thermostat) Cart Part No 4H.1343.02.0.00 , Adaptor(For Heat Exchanger) Cart Part No 4H.1343.04.0.00 , Bracket For Heat Exchanger Mntg Cart Part No 4H.1343.05.0.00 , Heat Exchanger(S/F Fresh Water) For 4R1040 F.F. Engines Cart Part No 4H.1343.14.0.00 , Hose He To Water Pump S F 3000Rpm Cart Part No 4H.1343.24.0.Pr , Air Cleaner F.F. Engines Cart Part No 4H.1345.01.0.00 , Air Cleaner Assemblys F Fire Fighting Cart Part No 4H.1345.10.0.00 , Guard For Air Cleaner Cart Part No 4H.1345.12.0.00 , Air Cleaner F.F. Engines Cart Part No 4H.1346.01.0.00 , Air Cleaner Assembly, S/F Fire Fighting Cart Part No 4H.1346.20.0.00 , Startersolenoid(Dumore, 535-0127) 12V For F.F. Engines Cart Part No 4H.1347.01.0.00 , Clamp For Raised Type Dipstick Cart Part No 4H.1353.30.0.00 , Water Heaterkim Hotstarttps102gt12 0031Kw240v Cart Part No 4H.1355.01.0.00 , Hose For Water Heater Pipe Cart Part No 4H.1355.05.0.00 , Rubber Hose(For Water Heater) Cart Part No 4H.1355.13.0.00 , Fuel Pipe From Feed Pump To Fuel Filter Cart Part No 4H.1359.22.0.Pr , Fuel Pipe From Fuel Filter To Fip Cart Part No 4H.1359.24.0.Pr , Turbocharger Cart Part No 4H.136.10.0.00 , Turbocharger K16 2371N 5 82 For 4R1040tc Hyundai Cart Part No 4H.136.11.0.Pr , Turbocharger Cart Part No 4H.136.20.0.00 , Rectifier Diode Bridge 16Amp Hind Model No Hb37 02 Cart Part No 4H.1364.12.0.00 , Fire Pump Engine Display Controller 12Vdc Cart Part No 4H.1364.33.0.00 , Selector Switch Assembly M22 Wrk A K10 K01 Maintained Cart Part No 4H.1364.37.0.00 , Selector Switch Assembly Cart Part No 4H.1364.38.0.00 , Instrument Control Panel Assembly Digital Disply 12Vdc Cart Part No 4H.1364.60.0.00 , Fuel Supply Pipe (From Supply Block To Fuel Pump) Cart Part No 4H.1374.06.0.00 , Fuel Supply Pipe For 4R1040na Engine Cart Part No 4H.1374.08.0.00 , Leak Off Pipe Assembly Cart Part No 4H.1374.09.0.Pr , Fuel Supply And Retun Block Cart Part No 4H.1375.03.0.00 , Extension Pipe For Fuel Supply Cart Part No 4H.1375.06.0.00 , Extension Pipe For Fuel Return Cart Part No 4H.1375.07.0.00 , Gasket: Cylinder Head 1.22 Mm Thk Cart Part No 4H.1377.02.0.00 , Cylinder Head Assembly Complete Cart Part No 4H.1377.30.0.00 , Lss Turbocharger For 6K1080 Crdi Cart Part No 4H.1378.07.0.Pr , Plastic Cap For Water Pump Inlet Cart Part No 4H.138.23.0.00 , Suction Tube Cart Part No 4H.1385.40.0.00 , Lube Oil Sump Assly Cart Part No 4H.1386.10.0.00 , Lube Oil Sump Assembly Cart Part No 4H.1386.50.0.00 , Camshaft Assy4k Engine Cart Part No 4H.1387.10.0.00 , Camshaft Assy4k Engine Cart Part No 4H.1387.40.0.00 , Camshaft Assembly4k Engine 4V Common Rail Cart Part No 4H.1387.80.0.Pr , Dipstick Assembly Cart Part No 4H.1388.50.0.00 , Sub Assembly Of Rocker Cover & Breather Tube Cart Part No 4H.139.30.0.00 , Fip: 4R1040t Cart Part No 4H.1390.01.0.00 , Adaptorfor Breather Pipe Cart Part No 4H.140.01.0.00 , Breather Pipe Cart Part No 4H.140.03.0.00 , Radiator Cap Cart Part No 4H.1410.20.0.00 , Aluminium Radiator Assembly Cart Part No 4H.1410.40.0.Pr , Adaptor On Header Cart Part No 4H.1415.01.0.00 , Adaptor: Throttle Cabel Mtg Bkt Cart Part No 4H.1415.02.0.00 , Banjo Bolt Cart Part No 4H.1415.03.0.00 , Rubber Sleeve For Header (Spin On Filter Mounting Arrengement) Cart Part No 4H.1415.04.0.00 , Rubber Sleeve For Header (Spin On Filter Mounting Arrengement) Cart Part No 4H.1415.05.0.00 , Joint: Header Cart Part No 4H.1415.06.0.00 , Hose For Lub Oil 960 Mm (Both Ends Straight) Cart Part No 4H.1415.07.0.00 , Hose: Lube Oil 1030Mm One End 90? Cart Part No 4H.1415.08.0.00 , Rubbler Sleeve For Adblue Tank Clamp (25Litrs) Cart Part No 4H.1415.09.0.Pr , Hose For Lube Oil 600 Mm Cart Part No 4H.1415.12.0.00 , Bracket For Lub Oil Filter Mounting Cart Part No 4H.1415.13.0.00 , Hose For Lube Oil - Header To Filter Cart Part No 4H.1415.16.0.00 , Oil Return Pipe Cart Part No 4H.1415.17.0.Pr , Hose: Make Up Connection Cart Part No 4H.1424.03.0.00 , Hose: Make Up Water Connection Cart Part No 4H.1425.02.0.00 , Pipe (Thermostat To Radiator) Cart Part No 4H.1425.03.0.00 , Hose: Make Up Water Connection Cart Part No 4H.1425.04.0.00 , Aluminium Radiator: 4R1040t Cart Part No 4H.1425.20.0.00 , Aluminium Radiator Assembly Cart Part No 4H.1425.40.0.Pr , Injector Cart Part No 4H.1429.01.0.00 , Injector Cart Part No 4H.1429.05.0.00 , P Type Injectorassly Cart Part No 4H.1429.10.0.00 , Injector Assembly With Nozzle Cart Part No 4H.1429.14.0.00 , Injector Cart Part No 4H.1429.18.0.00 , Injectors For 3R1040ta G1 Cpcbii(56 Hp @ 1500 Rpm, Nha No. F002 C8z 981, Nozzle Tip N Cart Part No 4H.1429.23.0.00 , Injector With Vco 5X0 190X150x13deg17he 480Htfa 433 390 755With 3Mm Injector S Cart Part No 4H.1429.26.0.Pr , Packing Foot (Fwe,Starter Side) Cart Part No 4H.143.02.0.00 , Valve Seat Insert -Inlet Cart Part No 4H.1432.02.0.00 , Valve Seat Insert: Inlet Cart Part No 4H.1432.02.9.00 , Valve Seat Insert-Exhaust Cart Part No 4H.1432.03.0.00 , Valve Seat Insert: Exhaust Cart Part No 4H.1432.03.9.00 , Cylinder Head Assly Cart Part No 4H.1432.30.0.00 , Valve Pair Inlet & Exhaust Cart Part No 4H.1432.41.0.00 , Cylinder Head Assly Cart Part No 4H.1432.60.0.00 , Cylinder Head Reconditioning Kit 4R1040 Series (Indl Bsiii & Pg Engine Post 2011) Cart Part No 4H.1432.90.0.00 , Rocker Support Assembly Cart Part No 4H.1433.40.0.00 , Joint: Turbo Cart Part No 4H.1437.01.0.00 , Joint: Adaptor Cart Part No 4H.1437.02.0.00 , Adaptor (Turbocharger) Cart Part No 4H.1437.04.0.00 , Turbocharger Cart Part No 4H.1437.06.0.00 , Turbocharger Cart Part No 4H.1437.10.0.00 , Adaptor For Turbo Drain Cart Part No 4H.1437.11.0.00 , Jointfor Turbocharger Cart Part No 4H.1437.15.0.Pr , Joint Cart Part No 4H.1437.16.0.Pr , Oil Inlet Pipe Cart Part No 4H.1437.18.0.Pr , Lube Oil Drain Pipe Assembly Cart Part No 4H.1437.20.0.00 , Lube Oil Supply Pipe For Turbocharger Cart Part No 4H.1437.50.0.00 , Lube Oil Supply Pipe For Turbocharger Cart Part No 4H.1437.70.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 4H.1437.80.0.00 , Prsessure Gauge(0 - 100 Psi) Cart Part No 4H.1438.01.0.00 , Flexible Hose 1 1/4 Bsp Both Side S/F 6R1080ta Cooling Line. Cart Part No 4H.1438.24.0.00 , Avm For Cooling Line Mtg. S/F 6R & Sl90 Cart Part No 4H.1438.41.0.00 , Header For Lube Oil Cooler & Spin On Filter Cart Part No 4H.144.04.0.00 , Lube Oil Cooler -8 Plates Cart Part No 4H.144.05.0.00 , Header (For Lube Oil Cooler & Spin On Filter) (8 & 12 Plates) Cart Part No 4H.144.06.0.00 , Lub Oil Cooler8 Plates Cart Part No 4H.144.08.0.00 , Luboil Header Assembly Cart Part No 4H.144.100.0.00 , L O Cooler Header Assly Cart Part No 4H.144.60.0.00 , Drive Shaft[2040] For Fire Fighting Pump Application Cart Part No 4H.1441.19.0.00 , Injector Cart Part No 4H.1454.07.0.00 , Special Stud For Injector Cart Part No 4H.1454.13.0.00 , Nut For Injector Stud Cart Part No 4H.1454.14.0.00 , High Pressure Pipe Assembly Cart Part No 4H.1455.150.0.Pr , Engine Wiring Harnessassembly With 4Pin &15 Pin Connector Cart Part No 4H.1464.20.0.00 , Extended Harness Assembly Cart Part No 4H.1464.30.0.00 , Engine Wiring Harnessassembly With 4Pin &15 Pin Connector Cart Part No 4H.1464.40.0.00 , Engine Wiring Harness With Csa Unit With 420Ma Gems Sensor Cart Part No 4H.1464.70.0.00 , Engine Wiring Harness For 125Kva 4K With B12 Ecu Cart Part No 4H.1465.30.0.Pr , Engine Wiring Harness With Csa Unit Sf 4K1080 Engine Cart Part No 4H.1465.40.0.Pr , Engine Wiring Harness For 125Kva 4K With Csa Unit Cart Part No 4H.1465.50.0.Pr , Engine Wiring Harness For 4K 125Kva With Csa Unit Cart Part No 4H.1465.60.0.Pr , Engine Wiring Harness For 125Kva 4K With B12 Ecu Emerald Cart Part No 4H.1465.70.0.Pr , 2 7 Kw Grs Starter Cart Part No 4H.1465.72.0.Pr , Krm For Dse 4522 A2 Without Data Plan Cart Part No 4H.1469.02.0.Pr , Actuator Xadc225d1s 12For Fire Fighting Appln Cart Part No 4H.1475.03.0.00 , Governor Card Esd 5160For Fire Fighting Appln Cart Part No 4H.1475.04.0.00 , Mtgbracket For 24V Alternator Cart Part No 4H.1481.01.0.Pr , Water Pump Pulley : 100 Pcd Cart Part No 4H.1483.11.0.00 , Water Pump And Fan Pulley Cart Part No 4H.1483.12.0.00 , Water Pump Pulley-105 Pcd, Poly V,6Pk Cart Part No 4H.1483.15.0.00 , Alternator Pulley: 56.5 Pcd Cart Part No 4H.1484.11.0.00 , Alternator Pulley Cart Part No 4H.1484.12.0.00 , Alternator Pulley (59 Pcd, Poly V, 6Pk) Cart Part No 4H.1484.15.0.00 , Alternator Pulley59 Pcdpoly V8pk Cart Part No 4H.1484.16.0.Pr , Assembly For Raised Dipstick Cart Part No 4H.1488.10.0.00 , Dipstick Assembly Cart Part No 4H.1488.40.0.00 , V Belt Spax 1265 Cart Part No 4H.1489.01.0.00 , Exhaust Diffuser For Cmvr Turbo S/F Terex Series-Ii Project Cart Part No 4H.1491.01.0.00 , Poly V Belt Cart Part No 4H.1493.01.0.00 , Poly V Belt (8 Pk 1215 Epdm) Cart Part No 4H.1493.02.0.Pr , Poly V Belt (6Pk-1190) Cart Part No 4H.1493.03.0.00 , Poly V Belt 8Pk 1148 Epdm Cart Part No 4H.1493.07.0.Pr , Raw Water Pipe Cac To He Cart Part No 4H.1494.25.0.Pr , Actuator Assembly 12V Dc For Air Cooled Engines Cart Part No 4H.150.42.0.Pr , Actuator Assembly 12V Dc For 4Rta And 6Rta Ff Engines Cart Part No 4H.150.43.0.Pr , Actuator Assembly 12V Dc For Water Cooled Engines Cart Part No 4H.150.44.0.Pr , Actuator Assembly 12V Dc For 6R Engines Pg Cart Part No 4H.150.46.0.Pr , Actuator Assembly 12V Dc For Ea10 Engines Cart Part No 4H.150.48.0.Pr , Actuator Assembly 12V Dc For Ea16 Engines Cart Part No 4H.150.49.0.Pr , Actuator Assembly 24V Dc For Sl90 Ind Application Cart Part No 4H.150.51.0.Pr , Actuator Assembly 12V Dc, With Spring (Energies To Run) Cart Part No 4H.150.53.0.Pr , Actuator Assembly 12V Dc Cart Part No 4H.150.56.0.Pr , Actuator Assembly 12V Dc Cart Part No 4H.150.57.0.Pr , Actuator Assembly 12V Dc For 4Rna Ff Engines Cart Part No 4H.150.58.0.Pr , Actuator Assembly 12V Dc For R810 Ff Engines Cart Part No 4H.150.61.0.Pr , Actuator Assembly 24V Dc For Sl90 Ff Engines Cart Part No 4H.150.62.0.Pr , Actuator Assembly 24V Dc For 6R Engines Ff Cart Part No 4H.150.63.0.Pr , Piston Assly R1040na Cmvr Stg-Ii Cart Part No 4H.1502.10.0.00 , Turbocharger Hsg: Tr59_6.1 Cart Part No 4H.1519.01.0.00 , Turbocharger Cart Part No 4H.1519.02.0.00 , Turbocharger Cart Part No 4H.1519.04.0.00 , Tr59_6.1 Hsg Turbocharger Cart Part No 4H.1519.05.0.00 , Turbo In Lub Oil Pipe Cart Part No 4H.1519.10.0.00 , Turbo Out Lub Oil Pipe Cart Part No 4H.1519.20.0.00 , Flywheel Assembly Cart Part No 4H.1524.10.0.00 , Injector For 4R/6R Fmul Engines (F002 C8z 994) Cart Part No 4H.1529.02.0.00 , Piston Assembly Cart Part No 4H.153.10.0.00 , Rotary Fip: 4K1080ta 125 Kva Cart Part No 4H.1534.01.0.00 , Fip 12V System With Csa Cart Part No 4H.1534.11.0.00 , 4K Cpcb Ii Fip 24V System With Csa Cart Part No 4H.1534.12.0.00 , Injector Cart Part No 4H.154.10.0.00 , Exhaust Manifold For K-26 Turbocharger Cart Part No 4H.1543.01.0.00 , Air Pipeturbocharger To Inlet Manifold Cart Part No 4H.1543.02.0.00 , Air Pipe Turbo To Inlet Manifold Cart Part No 4H.1543.03.0.Pr , Exhaust Manifold Cart Part No 4H.1543.04.0.Pr , Bracket For Remote Hand Primer Pump Mounting Cart Part No 4H.1546.01.0.00 , Adaptor For Air Cleaner For Ace Cart Part No 4H.1547.01.0.00 , Flywheel Assembly Cart Part No 4H.1548.10.0.00 , Motorpal Fuel Injection Pump For 4R1040ta 2600 & 2350 Rpm Cart Part No 4H.1549.04.0.00 , Sub Assly Spl Banjo Bolt (For Oil Spray Nozzle) Cart Part No 4H.156.07.0.00 , Crankcase Assly Without Bearingsw O Guide Cart Part No 4H.156.100.0.00 , Piston Cooling Nozzle Cart Part No 4H.156.11.0.00 , Ccase Assly W/O Bearing Cart Part No 4H.156.20.0.00 , Mounting Bracket For Alternator Cart Part No 4H.1563.01.0.00 , Mounting Bracket For Alternator Cart Part No 4H.1563.02.0.Pr , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 4H.158.04.0.00 , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 4H.158.05.0.00 , Flywheel Housing Sae 3, 144.5 Width Cart Part No 4H.1584.01.0.00 , Bracket For Fuel Solenoid(Cold Starting Kit) Cart Part No 4H.1590.01.0.00 , Fuel Pipe Assembly Solenid To Heater Cart Part No 4H.1590.10.0.00 , Hose: Air Cleaner Cart Part No 4H.1591.01.0.00 , Sub Assembly Of Rocker Cover & Breather Pipe Cart Part No 4H.160.10.0.00 , Fuel Injection Pump 4R1040na 60Hp@1900Rpm Cart Part No 4H.1605.10.0.00 , Breather Pipe Cart Part No 4H.161.05.0.00 , Clip For Breather Pipe Cart Part No 4H.161.06.0.00 , Joint: Breather Pipe Cart Part No 4H.161.11.0.00 , Bend Pipe For Breather Hose Cart Part No 4H.161.15.0.00 , Bend Pipe For Breather Hose Cart Part No 4H.161.21.0.00 , Bend Pipe For Breather Hose Cart Part No 4H.161.27.0.Pr , Set Of Joints Cart Part No 4H.1612.56.0.Sp , Valve Seat Insert: Exhaust Cart Part No 4H.1613.04.9.00 , Valve Seat Insert: Inlet Cart Part No 4H.1613.05.9.00 , Injector Sleeve Cart Part No 4H.1613.06.0.00 , O Ring For Injector Sleeve Cart Part No 4H.1613.07.0.00 , Valve Stem Seal Cart Part No 4H.1613.11.0.00 , Valve Cup Cart Part No 4H.1613.14.0.00 , Spring Cup Cart Part No 4H.1613.15.0.00 , Valve Collet Cart Part No 4H.1613.16.0.00 , Valve Spring Cart Part No 4H.1613.17.0.00 , Valve Bridge Cart Part No 4H.1613.18.0.00 , Dowel For Rocker Support (4K1080 4 Valve) Cart Part No 4H.1613.27.0.00 , Cyl Head Assemblycomplete Cart Part No 4H.1613.30.0.00 , Valve Bridge (Finish) Cart Part No 4H.1613.36.0.00 , Cylinder Head Gasket -Mls Cart Part No 4H.1613.37.0.00 , Valve Guide & Snap Ring Assembly Cart Part No 4H.1613.50.0.00 , Bolt For Cylinder Head Cart Part No 4H.1613.52.0.Pr , Crank Pulley Cart Part No 4H.1613.53.0.Pr , Cylinder Head Gasket Cart Part No 4H.1613.54.0.Pr , Inlet & Exhaust Valve Pair Cart Part No 4H.1613.90.0.00 , Push Rod Cart Part No 4H.1614.16.0.00 , Spacer: Head & Rocker Box Cover Cart Part No 4H.1614.21.0.00 , Spacer (Id 9 X Od 14 X 9.5 L) Cart Part No 4H.1614.38.0.Pr , Valve Rocker Assembly Cart Part No 4H.1614.80.0.00 , Flywheel Housing Cart Part No 4H.1616.01.0.00 , Adaptor On Flywheel Cart Part No 4H.1617.02.0.00 , Flywheel Cart Part No 4H.1617.10.0.00 , Lube Oil Sump Cart Part No 4H.1618.01.0.00 , Baffle Plate Cart Part No 4H.1618.03.0.00 , Assembly Suction Tube Cart Part No 4H.1619.20.0.00 , Fan Spacer 60 Mm Cart Part No 4H.1621.02.0.00 , Spacer For Fan (50 Mm) Cart Part No 4H.1621.03.0.00 , L Odrain Pipe Cart Part No 4H.1622.02.0.Pr , Adaptor Assly For Turbo Drain Cart Part No 4H.1622.03.0.00 , Lo Drain Pipe Assembly Cart Part No 4H.1622.04.0.00 , Head Machined For Bolt 50.003.08.020 - Hyundai Project Cart Part No 4H.1622.05.0.00 , Rocker Box Cart Part No 4H.1624.02.0.00 , Grommet (For Rocker Cover) Cart Part No 4H.1625.03.0.00 , Rocker Cover Cart Part No 4H.1625.11.0.00 , Baffle Plate Cart Part No 4H.1625.23.0.00 , O Ring For Rocker Cover Cart Part No 4H.1625.26.0.00 , Dome Nut Cart Part No 4H.1625.27.0.00 , Spherical Washer Cart Part No 4H.1626.03.0.00 , Nozzle Clamp Cart Part No 4H.1626.05.0.00 , Nozzle Clamp (Finish) Cart Part No 4H.1626.08.0.00 , Joint: Air Inlet Manifold Cart Part No 4H.1629.03.0.00 , Inlet Manifold Cart Part No 4H.1629.04.0.00 , Gasket For Exhaust Manifold Cart Part No 4H.1630.02.0.00 , Exhaust Manifold Cart Part No 4H.1630.07.0.00 , Gasket (Bet. Cylinder Head & Exhaust Manifold) Cart Part No 4H.1630.09.0.Pr , Crankshaft Pulley Cart Part No 4H.1636.01.0.00 , Pulley For Alternator Cart Part No 4H.1637.01.0.00 , O Ring Cart Part No 4H.1641.02.0.00 , Thermostat & Housing Cart Part No 4H.1641.10.0.00 , Fuel Tank Unit Cart Part No 4H.1649.06.0.00 , Joint For Cover Plate Cart Part No 4H.1649.14.0.00 , Fuel Tank: 130 High Cart Part No 4H.1649.21.0.00 , Fuel Tank S/F: 180 High Cart Part No 4H.1649.24.0.00 , Fuel Tank Unit S F 205 Effective Tank Height Cart Part No 4H.1649.31.0.Pr , Fuel Tank Unit S F 180 Effective Tank Height Cart Part No 4H.1649.34.0.00 , Fuel Tank Unit With 272 Effective Height Cart Part No 4H.1649.37.0.00 , Fuel Tank Unit 280Mm Cart Part No 4H.1649.41.0.00 , Fuel Tank Unit S F 276 Effective Tank Height Cart Part No 4H.1649.42.0.Pr , Fuel Injection Pump Turbo -V.S. Cart Part No 4H.165.10.0.00 , Piston Assembly: Gallery Cooled Piston Cart Part No 4H.1650.10.0.00 , Piston Ring Set Cart Part No 4H.1650.20.0.00 , Piston Assembly Cart Part No 4H.1650.60.0.00 , Piston Assembly Complete Cart Part No 4H.1650.75.0.Pr , High Pressure Pipe Assembly Cart Part No 4H.1653.50.0.00 , Leak Off Pipe Cart Part No 4H.1658.01.0.00 , Leak Off Pipe For Fip & Injector Cart Part No 4H.1658.04.0.00 , Leak Off Pipe (For Filter) Cart Part No 4H.1658.07.0.00 , High Pressure Pipe Assembly Cart Part No 4H.1659.50.0.00 , Rubber Hose: Air Cleaner Cart Part No 4H.166.06.0.00 , Bracket For Air Cleaner Cart Part No 4H.166.08.0.00 , Air Cleaner Assly: Dry Type Cart Part No 4H.166.10.0.00 , Primary Filter Element Cart Part No 4H.166.11.0.00 , Clamp For Dipstick Assy. For 35 Deg Inclination Oil Sump Cart Part No 4H.1660.01.0.00 , Dipstick Assly Cart Part No 4H.1660.10.0.00 , Crank Pulley With Poly V Groove Cart Part No 4H.1661.01.0.00 , Water Pump Pulley Poly V Groove-138 Pcd Cart Part No 4H.1662.01.0.00 , Water Pump Pulley : Poly V Groove Cart Part No 4H.1662.11.0.00 , Alternator Pulley With Poly V Groove 90 Pcd Cart Part No 4H.1663.01.0.00 , Poly V Belt Cart Part No 4H.1664.01.0.00 , V Belt Sect 6Pk -1215 Poly Cart Part No 4H.1664.02.0.00 , 62 5 Kvaalternator Terminal Box Cart Part No 4H.1666.05.0.00 , 62.5 Kva Alternator Fan Cart Part No 4H.1666.06.0.00 , Alternatorwound Exciter Stator Cart Part No 4H.1666.07.0.00 , 62.5 Kva Alternator Wound Exciter Rotor Cart Part No 4H.1666.08.0.00 , 62.5 Kva Alternator Diode Bridge Rectifier Cart Part No 4H.1666.11.0.00 , Alternatorde Adaptor M Clsap 423Sae 3 60 Kva Cart Part No 4H.1666.12.0.00 , 62.5 Kva Alternator Nde Flange Cart Part No 4H.1666.14.0.00 , 62.5 Kva Alternator Coupling Disc Assly Cart Part No 4H.1666.15.0.00 , Space Heater Kit Cart Part No 4H.1666.16.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.167.01.0.00 , Adaptor Ring On K24 Turbocharger Cart Part No 4H.167.02.0.00 , Joint: Adaptor Ring Cart Part No 4H.167.03.0.00 , Dipstick Bracket S F Jcb Cart Part No 4H.1678.02.0.00 , Air Delivery Pipe Cart Part No 4H.168.01.0.00 , Rubber Hose: Compressor Outlet- K24 Turbo Cart Part No 4H.168.03.0.00 , Rubber Hose Cart Part No 4H.168.11.0.00 , Relay (12 Vdc)Mounting Box Cart Part No 4H.1684.09.0.00 , Cold Starting Kit Cart Part No 4H.1684.18.0.00 , Cold Start Power Relay Mounting Box Cart Part No 4H.1684.32.0.Pr , Engine Heater Wiring Kit Cart Part No 4H.1684.60.0.00 , Cold Startting Kit Cart Part No 4H.1684.71.0.Sp , Multifunction Timer Relay 12 240 V Ac Dc 2 C Ore22r2mmw 1Cmdtf Cart Part No 4H.1685.23.0.Pr , Assembly For 4K Engine Heater Kit Cart Part No 4H.1686.50.0.00 , 4K Air Heater Wiring Harness Cart Part No 4H.1686.60.0.Pr , Control Panel Assembly For 125Kva 4K Cpcb4 Cart Part No 4H.1686.90.0.Pr , Cold Start Kit Main Assembly For L3 Level Application 12V System4k 125Kva Cart Part No 4H.1689.30.0.Pr , Cold Start Kit Assembly For L3 Level Application 12V System82 5Kva Cart Part No 4H.1689.70.0.Pr , Inlet Cap (76 Dia Pipe) Cart Part No 4H.169.01.0.00 , Air Cleaner Assembly Cart Part No 4H.169.10.0.00 , Cold Start Kit Main Assembly For L2 Level Application(12V System) 4K 125Kva Cart Part No 4H.1690.30.0.Sp , Control Panel Schematic For 82 5Kva3ph With Kg645 Ip A Cart Part No 4H.1696.80.0.Pr , Control Panel Schematic For 82 5Kva3ph With Kg640 Ip A Cart Part No 4H.1696.90.0.Pr , Lifting Hook Cart Part No 4H.170.01.0.00 , Lifting Hook Cart Part No 4H.170.04.0.00 , Rotary Fip: 4R1040tc76 Hp @ 2200 Rpm Cart Part No 4H.1705.02.0.00 , Jointfor Rotary Fip Cart Part No 4H.1705.04.0.00 , Rotary Fip: 4R1040tc76 Hp @ 2200 Rpm Cart Part No 4H.1705.08.0.00 , Charging Alternator Cart Part No 4H.1706.01.0.00 , Charging Alternatorsealed Type12 14V 90A Cart Part No 4H.1706.11.0.Pr , Pulley 65 Pcd Spa V Section For Sealed Alternator Cart Part No 4H.1706.12.0.Pr , Pulley 68 Pcd Poly V 6Pk For Sealed Alternator Cart Part No 4H.1706.13.0.Pr , Rotary Fip 4R1040ta296 Hp @ 2200 Rpm Cart Part No 4H.1707.10.0.00 , Rotary Fip :4R1040ta3105 Hp @ 2200 Rpm Cart Part No 4H.1708.20.0.00 , Fan: 494 Dia 30 Deg Cart Part No 4H.1710.10.0.00 , Fan: 494 Dia 30 Deg Cart Part No 4H.1710.20.0.00 , Fuel Return Line Nrv Adaptor (Type Ii) Cart Part No 4H.1711.12.0.00 , Air Pipe(Turbocharger To Cac) Cart Part No 4H.1712.02.0.00 , Air Pipe(Cac To Air Inlet) Cart Part No 4H.1712.03.0.00 , Hose: Make Up Connection Cart Part No 4H.1712.07.0.00 , Stay Rod: Radiator Cart Part No 4H.1712.09.0.00 , Vent Pipe:Radiator Cart Part No 4H.1712.11.0.00 , Air Delivery Bend Cart Part No 4H.1712.15.0.00 , Hose: Air Pipe -Tc To Cac Cart Part No 4H.1712.18.0.00 , Bracket For Air Pipe Cart Part No 4H.1712.22.0.00 , Bracket For Gas Outlet Manifold Cart Part No 4H.1712.23.0.00 , Hose T-Bolt Clamp Cart Part No 4H.1712.24.0.00 , Air Pipe (Radiator To Bend Pipe) Cart Part No 4H.1712.28.0.00 , Bracket For Cac Pipe Cart Part No 4H.1712.29.0.00 , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 4H.1712.31.0.00 , Cac Hose (Hot Side 4 Plies) Cart Part No 4H.1712.32.0.00 , Cac Hose (Cold Side) Cart Part No 4H.1712.33.0.00 , Bracket For Cac Pipe Support Cart Part No 4H.1712.36.0.00 , Cac Hose (Cold Side) Cart Part No 4H.1712.39.0.00 , Air Pipe (Radiator To Bend Pipe) Cart Part No 4H.1712.49.0.Pr , Drain Pipe800 Mm Long Cart Part No 4H.1713.02.0.00 , Lube Oil Drainpipe From Pump To Base Plate Cart Part No 4H.1713.03.0.00 , Drain Pipe From Sump To Hand Pump Cart Part No 4H.1713.04.0.00 , Pipe-Thermostat To Radiator Cart Part No 4H.1714.05.0.00 , Hose: Radiator To Water Pump Cart Part No 4H.1714.06.0.00 , Pipe (Thermostat To Radiator Inlet) Cart Part No 4H.1714.07.0.00 , Expansion Bellow Cart Part No 4H.1715.01.0.00 , Expansion Bellow Cart Part No 4H.1715.04.0.00 , Expansion Bellow Cart Part No 4H.1715.05.0.00 , Anti Vibration Mounts Cart Part No 4H.1716.01.0.00 , Anti Vibration Mounts Cart Part No 4H.1716.02.0.00 , Spacer For Fan (40Mm) Cart Part No 4H.1717.02.0.00 , Fan Assly: 26 Pusher Cart Part No 4H.1717.03.0.00 , Spacer For Fan Cart Part No 4H.1717.07.0.00 , Pipe Radiator To Water Pump Cart Part No 4H.1718.02.0.00 , Breather Hose Rocker Cover To Bend Pipe Cart Part No 4H.1718.07.0.00 , Breather Hose Cart Part No 4H.1718.08.0.00 , Rotary Fip: 4R1040ta190 Hp @ 2200 Rpm Cart Part No 4H.1719.01.0.00 , Actuator With Spring Cart Part No 4H.1720.01.0.00 , Ecu: 4K1080ta-125 Kva Cart Part No 4H.1720.02.0.00 , Actuator With Reverse Spring Cart Part No 4H.1720.05.0.00 , Ecu With Csa Output Cart Part No 4H.1720.12.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.1724.10.0.00 , Cam Shaft & Gear Assembly Cart Part No 4H.1724.20.0.00 , Rotary Fip: 4R1040ta4110 Hp @ 2500 Rpm Cart Part No 4H.1729.01.0.00 , Control Panel Schematic For 4K 125Kva With Csa Unit Cart Part No 4H.1738.75.0.Pr , Adaptor For Air Cleaner Cart Part No 4H.174.02.0.00 , Poly V Belt : 6Pk 1230 Cart Part No 4H.1744.01.0.00 , Crankshaft Pulley 6Pk 145 Pcd Cart Part No 4H.1745.01.0.00 , Crank Pulley: Poly V Groove Cart Part No 4H.1746.01.0.00 , Water Pump Pulley: V Groove Cart Part No 4H.1747.01.0.00 , Alternator Pulley: Poly V Groove Cart Part No 4H.1748.01.0.00 , Crank Pulley: Poly V Groove Cart Part No 4H.1749.01.0.00 , Alternator Pulley: Poly V Groove Cart Part No 4H.1750.01.0.00 , Crank Shaft Pulley With Poly V Groove (P6pk172) Cart Part No 4H.1755.01.0.00 , Gear Casing Cart Part No 4H.178.02.0.00 , Mud Slinger (Bottom Side) Cart Part No 4H.178.07.0.00 , Bracket For Silencer Cart Part No 4H.1787.04.0.00 , Hose: Air Cleaner Cart Part No 4H.1787.05.0.00 , Hose: Air Cleaner Cart Part No 4H.1788.05.0.00 , Front Cover Cart Part No 4H.179.02.0.00 , Mud Slinger (Top Side) Cart Part No 4H.179.04.0.00 , Engine Wiring Harness: Kg934 Cart Part No 4H.1790.10.0.00 , Engine Wiring Harness Assembly Cart Part No 4H.1790.60.0.00 , Panel To Engine Wiring Harness Cart Part No 4H.1790.70.0.00 , Wiring Harness Assly: Surge Suppress Cart Part No 4H.1791.60.0.00 , Exhaust Manifold Cart Part No 4H.1792.01.0.00 , Engine Wiring Harnessassembly Sf Dse 4522 A2 Unit With Governerfor 4K Engine Cart Part No 4H.1792.30.0.Pr , Cross Member Forradiator Support Cart Part No 4H.1793.01.0.00 , Lube Oil Supply Pipe Assly Cart Part No 4H.1795.10.0.00 , Lube Oil Drain Pipe Assembly Cart Part No 4H.1795.20.0.00 , Hose: Pre Clean To Air Clean Bsiii Cart Part No 4H.1796.05.0.00 , Air Cleaner Assly 8 M3/Min Cart Part No 4H.1796.10.0.00 , Silencer Cart Part No 4H.1797.01.0.00 , Tail Pipe For Exhaust Silencer Of76 Hp 2200 Rpm Bs Iii Engine Cart Part No 4H.1797.02.0.00 , Clamp Assembly Cart Part No 4H.1797.20.0.00 , Bracket For Accelerator & Stop Cable Mounting Cart Part No 4H.1799.02.0.00 , Piston Assembly Cart Part No 4H.180.10.0.00 , Piston Assembly Completefor Fmul Application Cart Part No 4H.180.100.0.00 , Piston Assembly Cart Part No 4H.180.120.0.00 , Piston Assembly Complete Cart Part No 4H.180.15.0.00 , Hose: Water Pump To Radiator Cart Part No 4H.1800.01.0.00 , Dry Type Air Cleaner Assembly (8-M3min) Cart Part No 4H.1808.10.0.Pr , Crankshaft Assly With Gear Cart Part No 4H.181.10.0.00 , Crankshaft Assembly Cart Part No 4H.181.30.0.00 , Air Cleaner Safety Element Cart Part No 4H.1810.01.0.00 , Air Cleaner Primary Element Cart Part No 4H.1810.02.0.00 , Hose Redicer Bet Air Cleaner And Pre Cleaner Cart Part No 4H.1810.03.0.00 , Rubber Sleeve Small -For Pre-Cleaner Cart Part No 4H.1810.04.0.00 , Rubber Sleeve Large - For Air Cleaner Cart Part No 4H.1810.05.0.00 , Air Cleaner Cart Part No 4H.1810.50.0.00 , Air Cleaner Assly Cart Part No 4H.1810.60.0.00 , Exhaust Diffuser Cart Part No 4H.1812.01.0.00 , Poly V Belt 6Pk:1325 4R1040ta Cart Part No 4H.1814.02.0.00 , Fan: 494 Dia 35 Deg Cart Part No 4H.1818.10.0.00 , Fan: 494 Dia 35 Deg Cart Part No 4H.1819.10.0.00 , Exhaust Silencer Cart Part No 4H.1820.01.0.00 , Diffuser Cart Part No 4H.1821.01.0.00 , Bracket: Exh Diff Support Cart Part No 4H.1822.04.0.00 , Exhaust Diffuser Cart Part No 4H.1822.05.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.1822.07.0.Pr , Hose: Air Cleaner Cart Part No 4H.1823.01.0.00 , B12 E Governor Harness Diagram Serial Programming Cart Part No 4H.1825.11.0.Pr , B12 E Governor Serial Programming Harness Cart Part No 4H.1825.12.0.Pr , Engine To Panel Wiring Harnessassembly With 4Pin15 Pin Connector Cart Part No 4H.1825.30.0.00 , Crankshaft Pulley Cart Part No 4H.1827.02.0.00 , Crankshaft Pulley Cart Part No 4H.1827.03.0.00 , Bracket For Air Cleaner Mounting Cart Part No 4H.1828.01.0.00 , Hose: Air Cleaner Cart Part No 4H.1828.02.0.00 , Hose: Air Cleaner Cart Part No 4H.1828.03.0.00 , Safety Filter Element Cart Part No 4H.183.01.0.00 , Air Cleaner Assly: 8M3 Indl Cart Part No 4H.183.10.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 4H.1832.01.0.00 , Fuel Pipe: Mud Filter To Feed Pump Cart Part No 4H.1832.02.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.1832.03.0.00 , 230V Ac 16Mm Red Colour Lamp Cart Part No 4H.1840.15.0.00 , Crank Pulley Cart Part No 4H.1867.01.0.00 , Hose For Air Cleanerbs Iii Cart Part No 4H.1873.01.0.00 , Hose For Precleaner Cart Part No 4H.1873.02.0.00 , Raised Dipstick Assly Cart Part No 4H.1874.10.0.00 , F 002 A0z 964 Inline Fip4r1040ta102 Hp1500 Rpm Cpcb Ii Cart Part No 4H.1890.02.0.00 , Engine Wiring Harness Assembly With Kg 934 Cart Part No 4H.1904.40.0.00 , Engine Wiring Harness For 82 5Kva 4R1040 Emerald Cart Part No 4H.1904.90.0.Pr , Engine Wiring Harness For 4Rta Engine Cart Part No 4H.1905.70.0.Pr , Shim For Speed & Phase Sensors Cart Part No 4H.1911.03.0.00 , Shim For Speed Phase Sensorsthick 0 8 Cart Part No 4H.1911.06.0.00 , Shim For Speed Phase Sensorsthick 1 1 Cart Part No 4H.1911.07.0.00 , Shim For Speed Phase Sensorsthick 1 5 Cart Part No 4H.1911.08.0.00 , Hub For Fuel Pump Gear S F Common Rail Engine Cart Part No 4H.1915.01.0.00 , Pipe Assembly (From Pump To Solenoid) Cart Part No 4H.1926.01.0.00 , Pipe Assemblysolenoid To Heater Cart Part No 4H.1926.02.0.00 , Bracket For Solenoid Mounting Cart Part No 4H.1926.03.0.00 , Routed High Pressure Pipe 1Pump To Rail Cart Part No 4H.1927.101.0.Pr , Routed High Pressure Pipe 2Pump To Rail Cart Part No 4H.1927.102.0.Pr , Routed High Pressure Pipe Cylinder 1Rail To Injector Cart Part No 4H.1927.111.0.Pr , Routed High Pressure Pipe Cylinder 2Rail To Injector Cart Part No 4H.1927.112.0.Pr , Routed High Pressure Pipe Cylinder 3Rail To Injector Cart Part No 4H.1927.113.0.Pr , Routed High Pressure Pipe Cylinder 4Rail To Injector Cart Part No 4H.1927.114.0.Pr , Gear Casings F Hydraulic Pump Cart Part No 4H.1930.01.0.Pr , Bracket For Alternator Mounting Cart Part No 4H.1930.03.0.Pr , Cover For Cam Bore Cart Part No 4H.1930.06.0.Pr , Cover For Hyd. Pump Bore Cart Part No 4H.1930.07.0.00 , Joint (For Gear Casing) Cart Part No 4H.1930.08.0.00 , Joint (For Compressor Cover) Cart Part No 4H.1930.09.0.00 , Joint (For Gear Cover) Cart Part No 4H.1930.11.0.00 , Joint (For Fip Cover) Cart Part No 4H.1930.12.0.00 , Cam Tone Wheels F Common Rail Cart Part No 4H.1932.05.0.Pr , Cam Tone Wheel3 Tooth Cart Part No 4H.1932.08.0.Pr , Bend Pipe For Throttle Cart Part No 4H.1934.05.0.Pr , Gasketfor Adaptor Cart Part No 4H.1934.06.0.00 , Valve Bridge (Finish) (4K 4V, Common Rail) Cart Part No 4H.1938.03.0.Pr , Adaptorfor Centrifuge Luboil Filter Cart Part No 4H.1939.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.1942.02.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No 4H.1942.03.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 4H.1942.12.0.00 , Fuel Pipefuel Filter To Fip Cart Part No 4H.1942.13.0.00 , High Pressure Pipe Assembly Cart Part No 4H.1943.60.0.00 , Lube Oil Pump Cart Part No 4H.1944.30.0.00 , Cylinder Head Assly Complete Cart Part No 4H.1946.70.0.Pr , H.P.Pipe Complete Set (700 Mm) Cart Part No 4H.1950.60.0.00 , Exhaust Diffuser Cart Part No 4H.1951.01.0.00 , Jointbetween Turbo Diffuser Cart Part No 4H.1951.02.0.00 , Bracket For Diffuser Cart Part No 4H.1951.03.0.00 , Heat Shield (Integral With Diffuser Joint) Cart Part No 4H.1951.04.0.00 , Bracket For Diffuser Support Cart Part No 4H.1951.17.0.Pr , Oil Supply Pipe For Fip Cart Part No 4H.1960.10.0.Pr , Exhaust Diffuser Cart Part No 4H.1966.01.0.Pr , Locating Bolt : 65Mm Eye Bolt Cart Part No 4H.198.02.0.00 , Spacer (For Eye Bolt) Cart Part No 4H.198.03.0.00 , Belt Guard Cart Part No 4H.198.04.0.00 , Belt Gaurd For Alternator Cart Part No 4H.198.07.0.00 , Belt Guard For Charching Alt Cart Part No 4H.198.19.0.00 , Belt Guard For Alt Cart Part No 4H.198.21.0.00 , Charging Alternator Belt Guard Cart Part No 4H.198.61.0.Pr , Closed Crankcse Ventilation (Ccv) Cart Part No 4H.1989.01.0.Pr , Adaptor Cart Part No 4H.1989.09.0.Pr , Headerfor Lub Oil Cooler Spin On Filter Cart Part No 4H.1990.01.0.Pr , Gasket For Lub Oil Header Cart Part No 4H.1990.02.0.Pr , Header Cart Part No 4H.1990.03.0.Pr , Socket Head Grub Screw - M24x1.5X40 Cart Part No 4H.1990.04.0.Pr , Socket Head Grub Screw - M20x1.5X30 Cart Part No 4H.1990.05.0.Pr , Alternator Fan Od 421 Mm Frame Kg 44 3 Cart Part No 4H.1996.55.0.Pr , Belt V Type A Section Epdm V13x1318 Cart Part No 4H.1998.01.0.00 , Ecu Cart Part No 4H.1999.02.0.00 , Ecu Cart Part No 4H.1999.03.0.Pr , Joint: Sheet Metal Sump Cart Part No 4H.201.01.0.00 , Hose: Air Cleaner Cart Part No 4H.215.01.0.00 , Exhaust Manifold Cart Part No 4H.220.01.0.00 , Fuel Filter Cartridge Cart Part No 4H.2206.01.0.00 , Fuel Filter Assly Cart Part No 4H.2206.10.0.00 , Fuel Filter Assly-Rotry Fip Cart Part No 4H.2206.30.0.00 , Main Fuel Filter Cartridge With 3 Stage Water Separation Cart Part No 4H.2206.60.0.Pr , Expansion Bellow: K24 Turbo Cart Part No 4H.221.06.0.00 , Hexagonal Socket Head Cap Screw M8x18l Cart Part No 4H.221.07.0.00 , Exhaust Diffuser Cart Part No 4H.221.08.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.221.09.0.00 , Lube Oil Inlet Pipe Cart Part No 4H.222.01.0.00 , Lube Oil Drain Pipe Cart Part No 4H.222.03.0.00 , Air Inlet Manifold Cart Part No 4H.223.01.0.00 , Air Inlet Manifold(S/F Flame Heater Mounting) Cart Part No 4H.223.03.0.00 , Inlet Manifold Cart Part No 4H.223.04.0.00 , Inlet Manifold Cart Part No 4H.223.05.0.00 , Joint: Air Inlet Manifold Cart Part No 4H.223.11.0.00 , Bracket For Air Pipe Cart Part No 4H.224.02.0.00 , U Clamp Cart Part No 4H.224.03.0.00 , Air Pipe: Cac To Air Inlet Mfold Cart Part No 4H.224.04.0.00 , Air Pipe Turbo Side Cart Part No 4H.224.06.0.00 , Air Pipe Cac Side Cart Part No 4H.224.07.0.00 , Joint: Air Pipe Cart Part No 4H.224.08.0.00 , Cap Forcacpipe Cart Part No 4H.224.13.0.00 , Air Delivery Bend Cart Part No 4H.224.14.0.00 , Spacer (Between Turbo & Air Pipe) Cart Part No 4H.224.15.0.00 , O Ring: Spacer - Turbo & Air Pipe) Cart Part No 4H.224.16.0.00 , Air Pipecac To Air Inlet4k1080 4V Cart Part No 4H.224.17.0.00 , Air Pipe Cac To Inlet Manifold Cart Part No 4H.224.21.0.00 , Joint: Air Inlet Manifold & Air Pipe Cart Part No 4H.224.35.0.00 , Air Pipe (Bend) Cart Part No 4H.224.43.0.00 , Air Pipe Cart Part No 4H.224.44.0.00 , Flange Heater Cart Part No 4H.224.45.0.00 , Flange Heater 24V Cart Part No 4H.224.48.0.00 , V Bend Clampdia 72 4 Cart Part No 4H.224.53.0.Pr , Spacer (Cac Pipe & Bend Pipe) Cart Part No 4H.224.54.0.Pr , O Ring Cart Part No 4H.224.57.0.Pr , Cac Hosecold Side Cart Part No 4H.224.68.0.Pr , Air Delivery Pipe Cart Part No 4H.224.72.0.Pr , Flange Heater 0 5 Kw Cart Part No 4H.224.98.0.Pr , Flange Heater 1 5Kw Cart Part No 4H.224.99.0.Pr , Bracket For Radiator Stay Cart Part No 4H.225.01.0.00 , Stay For Radiator Cart Part No 4H.225.02.0.00 , Spacer For Bracket Cart Part No 4H.225.06.0.00 , Vent Pipe Cart Part No 4H.225.09.0.00 , Adaptor Forvent Pipe Cart Part No 4H.225.11.0.00 , Hose: Makeup Water Line Cart Part No 4H.225.12.0.00 , Spacer For Vent Connection Cart Part No 4H.225.13.0.00 , Adaptor: Water Temp Switch Cart Part No 4H.225.14.0.00 , Adaptor For Water Temp. Sensor Cart Part No 4H.225.22.0.00 , Stay For Radiator Cart Part No 4H.225.25.0.00 , Adaptor For Water Temp Switch Cart Part No 4H.225.29.0.00 , Adaptor For Raw Water Tempswitch Cart Part No 4H.225.43.0.Pr , Flange Heater 12V Dc 1000 Watts Cart Part No 4H.225.61.0.Pr , Pipe (Thermostat To Radiator Inlet) Cart Part No 4H.226.02.0.00 , Rubber Pipe: Radiator Out To Water Pump Cart Part No 4H.226.06.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 4H.226.08.0.00 , Hose: Make Up 4R Ta Cart Part No 4H.226.14.0.00 , Hose :Thermostat To Radiator Inlet Cart Part No 4H.226.15.0.00 , Hose: Rad Out To Engine In Cart Part No 4H.226.16.0.00 , Air Cleaner Mtg Bracket Cart Part No 4H.227.01.0.00 , Hose: Air Cleaner Cart Part No 4H.227.02.0.00 , Air Cleaner Bracket For 6H.412.20 Air Cleaner Cart Part No 4H.227.11.0.00 , Hose: Air Cleaner Cart Part No 4H.227.12.0.00 , Rubber Hose (For Air Cleaner) Cart Part No 4H.227.22.0.00 , Crankcase Foot(F P Side 225 Ht) Cart Part No 4H.228.01.0.00 , Crankcase Foot (Starter Side 225 Ht) Cart Part No 4H.228.02.0.00 , Bracket For Mud Filter Cart Part No 4H.228.11.0.00 , Spacer For 24V Starter (29.8 Mm Width) Cart Part No 4H.230.01.0.00 , Suction Tube Cart Part No 4H.231.10.0.00 , Adaptor: Lube Oil Press Sensor Cart Part No 4H.235.01.0.00 , Adaptor For Lopswitch Cart Part No 4H.235.11.0.00 , Adaptor For Lop Sensor Cum Switch Cart Part No 4H.235.12.0.00 , Adaptor Cart Part No 4H.235.15.0.00 , Intermediate Gear Support Cart Part No 4H.237.01.0.00 , Intermediate Gear Support Cart Part No 4H.237.02.0.00 , S.G.Iron Foot Cart Part No 4H.239.01.0.00 , Water Pump Sub Assembly Cart Part No 4H.242.10.0.00 , Major Overhaul Kit Cart Part No 4H.246.10.0.Sp , Major Overhaul Kit 4R1040 Cmvr Cart Part No 4H.246.20.0.Sp , Leak Off Pipe Sub Assly Cart Part No 4H.247.10.0.00 , Water Pump Assly With Pulley Cart Part No 4H.251.10.0.00 , Leak Off Pipe Sub Assly Cart Part No 4H.252.10.0.00 , Leak Off Pipe Assly: 4K1080ta Cart Part No 4H.252.30.0.00 , Inlet Exhaust Valve Pair Cart Part No 4H.253.41.0.Sp , Feed Pump Cart Part No 4H.2579.03.0.00 , Hosefor Air Cleaner 45 X 45 X 90Deg Cart Part No 4H.258.05.0.00 , Crankshaft Pulley Cart Part No 4H.261.01.0.00 , Water Pump Pulley-120 Pcd Spa Section Cart Part No 4H.262.01.0.00 , Alternator Pulley(90 Pcd) Cart Part No 4H.263.01.0.00 , Radiator Fan 17 Inch Sucker Cart Part No 4H.267.01.0.00 , Radiator Fan: 24 Pusher Cart Part No 4H.271.01.0.00 , Gasket For Turbochargerbetexhmanifold Turbocharger Cart Part No 4H.277.05.0.00 , Turbocharger Cart Part No 4H.277.10.0.00 , Monoblock Crankcase W O Bearing Cart Part No 4H.292.10.0.00 , Lube Oil Sump: Ci Btm Drain Plg Cart Part No 4H.294.02.0.00 , Baffle Plate Cart Part No 4H.294.04.0.00 , Flywheel Assembly Cart Part No 4H.295.10.0.00 , Suction Tube Assembly Cart Part No 4H.297.20.0.00 , Silencer Bracket Cart Part No 4H.301.01.0.00 , U-Clamping Stud Cart Part No 4H.301.02.0.00 , Joint: Turbo (Diffuser Side) Cart Part No 4H.302.03.0.00 , Spacer For Radiator Fan (40 Mm) Cart Part No 4H.303.02.0.00 , Wet Pm Kit (W/O Oil) For 4H.3048 Cart Part No 4H.304.8.0.Sp , Coolant Testing Kit Cart Part No 4H.307.10.0.00 , Alternator: 12V 90A Cart Part No 4H.311.02.0.00 , Plate For Fuel Filter: Inlet Mfold Cart Part No 4H.317.01.0.00 , Nozzle Leak Off Pipe Cart Part No 4H.323.10.0.00 , Suction Tube Cart Part No 4H.324.10.0.00 , High Pressure Pipe Set 700Mm Cart Part No 4H.325.10.0.00 , Pipe, Radiator To Pump Inlet Cart Part No 4H.328.01.0.00 , Hose: 45 Idx 5.2 Thk X 95L Cart Part No 4H.328.02.0.00 , Clamp Top For Water Inlet Pipe (Ltk) Cart Part No 4H.328.05.0.00 , Clamp Bottom For Water Inlet Pipe (Ltk) Cart Part No 4H.328.06.0.00 , Bush For Alternator Mounting Cart Part No 4H.329.05.0.00 , Locating Bolt: M8x35 Cart Part No 4H.329.23.0.00 , Eye Bolt (190Mm) Cart Part No 4H.329.24.0.00 , Swivel Piece Cart Part No 4H.329.26.0.00 , Locating Bolt M10 X55mm Cart Part No 4H.329.27.0.00 , Lub Oil Supply Hose Cart Part No 4H.333.01.0.00 , Fuel Filter Ctg-Duplex Type Cart Part No 4H.333.03.0.00 , Fuel Leak Off Pipe: Wire Braided Cart Part No 4H.334.02.0.00 , Flywheel Housing Cart Part No 4H.339.01.0.00 , Exhaust Manifold Cart Part No 4H.343.03.0.00 , Sealing Washer ( For M6) Cart Part No 4H.345.32.0.Pr , Inlet Manifold (Top & Fwe Opening) Cart Part No 4H.346.01.0.00 , Blanking Plate For Inlet Manifold Cart Part No 4H.346.06.0.00 , Joint: Blanking Plate Cart Part No 4H.346.07.0.00 , Inlet Manifold (Top Opening) Cart Part No 4H.346.11.0.00 , Joint: Exhaust Diffuser Cart Part No 4H.357.02.0.00 , Joint For Front Cover ( Ts 9013 ) Cart Part No 4H.358.04.0.00 , Gear End Oil Seal 80X105x12 Cart Part No 4H.358.06.0.00 , Oil Deflector Plate Cart Part No 4H.358.12.0.00 , Lube Oil Sump: Drain Plug-Fip Side Cart Part No 4H.359.01.0.00 , Joint For Lub Oil Sump Cart Part No 4H.359.02.0.00 , Hose Straight: 70Mm L Central Hump Cart Part No 4H.366.07.0.00 , Hose: Turbo Drain Pipe 170Mm Cart Part No 4H.366.08.0.00 , Hose For Turbo Drain Pipe Cart Part No 4H.366.12.0.00 , Bolt : Crank Pulley Cart Part No 4H.370.02.0.00 , Crankshaft Gear Cart Part No 4H.371.02.0.00 , Crankshaft Assly Cart Part No 4H.371.50.0.00 , Shaft: Lube Oil Pump Intermediate Gear Cart Part No 4H.372.01.0.00 , Hard Washer - Intermediate Gear Cart Part No 4H.372.02.0.00 , Cover For Fuel Pump Bore Cart Part No 4H.373.01.0.00 , O Ring: Fuel Pump Cover Cart Part No 4H.373.02.0.00 , Adaptor For Tacho Drive Unit Cart Part No 4H.375.01.0.00 , Joint: Tacho Drive Unit Adaptor Cart Part No 4H.375.02.0.00 , Injector Cart Part No 4H.376.20.0.00 , Camshaft Subassembly Cart Part No 4H.380.20.0.00 , Leak Off Pipe Assly. Cart Part No 4H.381.20.0.00 , Exhaust Manifold Cart Part No 4H.383.01.0.00 , Header (For Lo& Spin On Filter) Cart Part No 4H.385.01.0.00 , Lube Oil Cooler -12 Plates Cart Part No 4H.385.02.0.00 , Spacer: Fan Cart Part No 4H.390.01.0.00 , Water Pump Pulley 108 Pcd Cart Part No 4H.394.01.0.00 , Thermostat Housing Cart Part No 4H.395.10.0.00 , Lub Oil Sumpfor 4Wd Engine Cart Part No 4H.396.06.0.Pr , Dipstick Assembly For 4Wd Engine Cart Part No 4H.396.10.0.Pr , Exhaust Diffuser With Triangular Flange Cart Part No 4H.398.05.0.00 , Dog Bone For K24 Tc Cart Part No 4H.398.11.0.00 , Tc Housing For Dog Bone Cart Part No 4H.398.12.0.00 , Exhaust Diffuser With Triangular Flange Cart Part No 4H.398.13.0.00 , Bracket For Exhaust Diffuser Cart Part No 4H.398.14.0.00 , Plate For Fuel Filter Cart Part No 4H.399.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.399.02.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No 4H.399.03.0.00 , Raised Dipstick Assembly(350 Mm) Cart Part No 4H.401.10.0.00 , Thermostat Hsg Assembly Cart Part No 4H.402.20.0.00 , Bracket For Air Cleaner Cart Part No 4H.404.01.0.00 , Rubber Hose Cart Part No 4H.404.02.0.00 , Adapter For Air Cleaner Cart Part No 4H.404.03.0.00 , Pipe: Radiator-Pump Inlet Cart Part No 4H.405.01.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 4H.405.02.0.00 , Hose: Make Up Water Connection Cart Part No 4H.405.03.0.00 , Hose: Thermostat To Radiator Inlet Cart Part No 4H.405.04.0.00 , Rubber Hose: Radiator Air Vent Cart Part No 4H.405.05.0.00 , Stainless Steel Hose Clip S/F 45 To 61 Mm Hose O.D. (To Replace 50519/11) Cart Part No 4H.405.06.0.00 , Stainless Steel Hose Clip S/F 35 To 41 Mm Hose O.D (To Replace 50519/08) Cart Part No 4H.405.07.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 4H.405.08.0.00 , Hose: Water Pump Inlet To Radiator Outlet Cart Part No 4H.405.09.0.00 , Radiator Support( F.I.P. Side) Cart Part No 4H.406.01.0.00 , Radiator Support (Starter Side) Cart Part No 4H.406.02.0.00 , Stay (For Radiator) Cart Part No 4H.406.04.0.00 , Air Pipe (Turbocharger To Inlet Manifold) Cart Part No 4H.410.01.0.00 , Air Cleaner Assly: 9.5M3/M Cart Part No 4H.412.03.0.00 , Pvc Pipe For Air Cleaner (Suction Side) Cart Part No 4H.412.05.0.00 , Bracket For Air Cleaner Cart Part No 4H.412.09.0.00 , Hose For Air Cleaner Cart Part No 4H.412.32.0.Pr , Thermostat Assembly Cart Part No 4H.415.10.0.00 , Adaptor (For Temperature Gauge) Cart Part No 4H.416.01.0.00 , Alternator: 24V 55A Cart Part No 4H.422.01.0.00 , Alternator: Wo Blocking Diode Cart Part No 4H.422.02.0.00 , High Press Pipe Set 640Mm Cart Part No 4H.425.10.0.00 , Avr Programming Kit Usd2dxr Cart Part No 4H.4251.76.0.00 , Tail Pipe For 4R1190ta 82 5Kva Cpcb Iv Cart Part No 4H.429.03.0.Pr , Exhaust Flange For Pipe Outlet (8 Holes X 20 Dia X 190.5 Pcd / 230 O.D. X 110 I.D. X 116 Cart Part No 4H.429.08.0.Pr , Lifting Hookgear End Side Cart Part No 4H.433.02.0.00 , Crankshaft Assly. With Gear Cart Part No 4H.437.10.0.00 , Rubber Hose Cart Part No 4H.442.01.0.00 , Sleeve (For Air Cleaner Hose) Cart Part No 4H.442.02.0.00 , Rubber Hose Cart Part No 4H.442.03.0.00 , Hose: Air Cleaner Cart Part No 4H.442.04.0.00 , Adaptor For Lube Oil Supply Pipe Cart Part No 4H.443.02.0.00 , Joint: Adaptor (On Crankcase) For Turbo & Compr Oil Cart Part No 4H.443.07.0.00 , Lube Oil Inlet Pipe (For Compressor) Cart Part No 4H.444.01.0.00 , Adaptor For Oil Supply Pipe To Compressor Cart Part No 4H.444.02.0.00 , Lube Oil Inlet Pipe (For Compressor) Cart Part No 4H.444.03.0.00 , Joint For Exhaust Silencer With (174 Od) S/F Un Shanti Cart Part No 4H.445.08.0.00 , Rain Cap Cart Part No 4H.446.50.0.00 , Fuel Pipe Cart Part No 4H.448.36.0.00 , Fuel Cap Cart Part No 4H.448.37.0.00 , Fuel Pipe 75 Mm Length Cart Part No 4H.449.03.0.00 , Spacer For Battery Clampingi D7 O D12 Length 20 For Shanti Proj Cart Part No 4H.450.06.0.00 , Terminal Sleeve (Red) Cart Part No 4H.450.16.0.00 , Terminal Sleeve (Black) Cart Part No 4H.450.17.0.00 , Battery Cable 50 Sqmm For L3 Cold Start Cart Part No 4H.450.26.0.Pr , Battery Cable 50 Sqmm For L3 Cold Start Cart Part No 4H.450.70.0.Pr , Clamping Fasteners Assembly Cart Part No 4H.450.90.0.Pr , Water Pump Belt 3 Cart Part No 4H.465.46.0.00 , Rubber Hose: Radial Seal Air Cleaner Cart Part No 4H.471.03.0.00 , Stud Coupler (115 Mm Long) Cart Part No 4H.472.02.0.00 , Nut : M6x1lh Thread Cart Part No 4H.472.03.0.00 , Spacer ( I.D 7,O.D 13 , L 25 Mm ) Cart Part No 4H.472.04.0.00 , Spacer 7Id, 13Od & 10 Mm Long Cart Part No 4H.472.05.0.00 , Lever For Electronic Actuator Cart Part No 4H.472.07.0.00 , Bracket For Actuator Cart Part No 4H.472.09.0.00 , Spacer For Linkage Cart Part No 4H.472.13.0.00 , Lever For Electronic Actuator Cart Part No 4H.472.14.0.00 , Volt Suppressor: B12 Ecu Cart Part No 4H.472.15.0.00 , Bracket For Actuator Cart Part No 4H.472.66.0.00 , Bracket For Actuator Cart Part No 4H.472.67.0.00 , Tension Spring Cart Part No 4H.482.03.0.00 , Spring Holding Bolt Modified, Ltk Cart Part No 4H.482.09.0.00 , Bracket For Stop Lever Mounting Cart Part No 4H.482.14.0.00 , Adaptor For Fuel Inlet (Both End M14x15) Cart Part No 4H.486.01.0.00 , Adaptor M14 X M16 U Cart Part No 4H.486.05.0.00 , Leak Off Pipe Sub Assly Cart Part No 4H.486.10.0.00 , Fuel Pipe From Fuel Tank To Feed Pump Cart Part No 4H.486.103.0.Pr , Fuel Pipe Tank To Mud Filter Cart Part No 4H.486.13.0.00 , Fuel Return Pipe Cart Part No 4H.486.14.0.00 , Fuel Pipe Cart Part No 4H.486.15.0.00 , Fuel Return Pipe Cart Part No 4H.486.21.0.Pr , Drain Pipe Cart Part No 4H.486.24.0.00 , Fuel Pipe (Prefilter To Tank Unit) Cart Part No 4H.486.26.0.00 , Breather Hose Cart Part No 4H.486.33.0.00 , Fuel Return Pipe Cart Part No 4H.486.46.0.00 , Fuel Pipe Prefilter To Fip Cart Part No 4H.486.92.0.00 , Fuel Pipe (Feed Pump To Tank Unit) Cart Part No 4H.487.45.0.00 , Flange Cart Part No 4H.487.84.0.00 , Fuel Filling Hose: 36-125Kva For Skid Mounted Genset Cart Part No 4H.488.03.0.00 , Inlet And Oulet Connection For Fuel Tank Mail End Connection210 Height Cart Part No 4H.488.04.0.00 , Fuel Inlet Pipe Metailic Fip To Pre-Filter Cart Part No 4H.488.16.0.Pr , Fuel Inlet Pipe Metailic Pre Filter To Tank Cart Part No 4H.488.17.0.Pr , Fuel Hose-1 Cart Part No 4H.488.81.0.Pr , Fuel Hose-2 Cart Part No 4H.488.82.0.Pr , Fuel Pipewith Adaptor Cart Part No 4H.488.83.0.Pr , Fuel Pipe (From Tank To Nrv) Cart Part No 4H.488.84.0.Pr , Fuel Pipe (From Nrv To Pre-Filter) Cart Part No 4H.488.86.0.Pr , Kit For Electrical Fuel Feed Pump Fitment In 4K Cart Part No 4H.488.90.0.Sp , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Cart Part No 4H.489.11.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 1 Cart Part No 4H.489.12.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-1) Cart Part No 4H.489.14.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) Cart Part No 4H.489.15.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-3) Cart Part No 4H.489.16.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Cart Part No 4H.489.18.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Cart Part No 4H.489.19.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 1 Cart Part No 4H.489.21.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 2 Cart Part No 4H.489.22.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 3 Cart Part No 4H.489.23.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 4 Cart Part No 4H.489.24.0.Pr , Adaptor (On Air Inlet Mfold, Adaptor) Cart Part No 4H.491.01.0.00 , Spacer For Control Pannel (9Mm I.D. & 15Mm O.D. 10Mm L) Cart Part No 4H.493.08.0.00 , Adaptor For Lub Oil Supply Pipem10x1m10x1 Cart Part No 4H.495.01.0.00 , Flywheel Assly With Starter Ring Cart Part No 4H.505.10.0.00 , Sub Assembly Of Suction Tube Cart Part No 4H.506.10.0.00 , Rail Hfrn16+Rsd+Plv For 4K1080tae (122.1Kw @ 2500Rpm) Cev3 Cart Part No 4H.508.03.0.Pr , Phase Sensor Pg 3 8 For 4K1080tae122 1Kw 2500Rpmcev3 Cart Part No 4H.508.06.0.Pr , Engine Speed Sensor Dg6k For 4K1080tae122 1Kw 2500Rpmcev3 Cart Part No 4H.508.07.0.00 , Engine Speed Sensor Dg6k For 4K1080tae122 1Kw 2500Rpmcev3part No 0 281 002 Cart Part No 4H.508.07.0.Pr , Temperature Sensor: 4K1080tae 122.1Kw Cart Part No 4H.508.08.0.00 , Manifold Absolute Pressure Sensor Ds S3 Tf 4Bar For 4K1080tae122 1Kw 2500Rpm Cart Part No 4H.508.09.0.00 , Injector Cart Part No 4H.508.16.0.Pr , High Pressure Pump Cb28-3L-Ohw Cart Part No 4H.508.24.0.00 , Cri Injector For Bs Iv Project300 X 142 X 7 Cart Part No 4H.508.70.0.Pr , Cri Injector For Bs Iv Project Ks Nozzle375 X 142 X 7 Cart Part No 4H.508.73.0.Pr , Manifold Absolute Pressure Sensor For Na Gas Engines Cart Part No 4H.508.81.0.Pr , Injector Leak-Off Line Retaining Ring Cart Part No 4H.508.83.0.Pr , Injector For 6K1080ta 200 Kva Cpcb4 7 X 142 X 510K 1 3He 10 5 Cart Part No 4H.508.86.0.Pr , Phase Sensor 50% Threshold For Dv Cart Part No 4H.508.91.0.Pr , Intake Manifold Pressure Temperature Sensor(140Degc)_32Mpp14-3-Env_C Cart Part No 4H.508.94.0.Pr , Joint: Exh Diffuser Cart Part No 4H.522.03.0.00 , Exhaust Difusser Cart Part No 4H.522.04.0.00 , Adaptor: Oil Supply Cart Part No 4H.527.01.0.00 , Lube Oil Supply Assly Cart Part No 4H.527.10.0.00 , Lub Oil Drain Pipe Assembly Cart Part No 4H.527.20.0.00 , Silencer Assembly Cart Part No 4H.529.21.0.Pr , Expansion Bellow Cart Part No 4H.529.24.0.Pr , V Belt : Xpb1540 Cart Part No 4H.534.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.535.02.0.00 , Fuel Pipe: M12xm14-900L Cart Part No 4H.535.03.0.00 , Fuel Pipem12 X M141400 L Cart Part No 4H.535.04.0.00 , Hose: Air Cleaner Cart Part No 4H.536.02.0.00 , Hose: Air Cleaner Cart Part No 4H.536.04.0.00 , Adopter For Alternator Mounting Cart Part No 4H.541.02.0.00 , Spacer (10.5 I.D X 20 O.D. X 23 Length / Material - En1a Or M.S.) Cart Part No 4H.541.05.0.00 , Lifting Hook Gear End Side Cart Part No 4H.544.01.0.00 , Exhaust Adaptor Cart Part No 4H.546.01.0.00 , Mcb, 1Pole, 20 Amps Cart Part No 4H.5460.56.0.00 , Mcb, 1Pole, 4 Amps Cart Part No 4H.5460.58.0.00 , Bracket For Return Spring Cart Part No 4H.548.01.0.00 , Thermostat & Housing Cart Part No 4H.550.10.0.00 , Spacer: Radiator Fan 30Mm Cart Part No 4H.554.01.0.00 , Flange Cart Part No 4H.555.22.0.Pr , Lube Oil Cooler & Header Assly Cart Part No 4H.560.10.0.00 , Lub Oil Cooler And Header Assembly Cart Part No 4H.560.30.0.Pr , Lub Oil Cooler Header Assembly Cart Part No 4H.560.40.0.Pr , Spacer: 11 Idx 24 Od X 25.5 L Cart Part No 4H.561.01.0.00 , Fuel Pumpk Element: 4R1040 Cart Part No 4H.562.10.0.00 , Controller 8610 Mk Ii Cart Part No 4H.5660.81.0.00 , Hose: Fuel Filling Cart Part No 4H.572.07.0.00 , Dipstick Assembly Cart Part No 4H.573.10.0.00 , Raised Dipstick Assly: 350Mm Cart Part No 4H.578.10.0.00 , Low Fuel Level Sensor 145Mm Cart Part No 4H.585.14.0.00 , Fuel Level Sensor Cart Part No 4H.585.16.0.Pr , Fuel Injection Pump For 4R1040t Pg Cart Part No 4H.592.10.0.00 , Fuel Injection Pump : 4R1040ta-Pg Cart Part No 4H.594.10.0.00 , Leak Off Pipe Assly Cart Part No 4H.598.10.0.00 , Avmspolybond Modelp 772 For Ace Cart Part No 4H.606.02.0.00 , Flywheel Assly Cart Part No 4H.615.10.0.00 , Crank Pulley 172 Pcd, 1 Gr,Spa Cart Part No 4H.616.01.0.00 , Mud Slinger (For P92) Cart Part No 4H.616.03.0.00 , Water Pump Pulley: 120Pcd Cart Part No 4H.618.01.0.00 , Water Pump Assly 282.5 Crs Pulley Cart Part No 4H.618.10.0.00 , Adaptor For Air Cleaner Cart Part No 4H.626.11.0.00 , Rubber Hose For Air Cleaner Cart Part No 4H.626.12.0.00 , Bracket For Air Cleaner Mounting On Inlet Manifold Cart Part No 4H.626.13.0.00 , Spacer For Air Cleaner Bracket (Od 20X Id 9 X L 52) Cart Part No 4H.626.14.0.00 , Mounting Plate For Fuel Filter Cart Part No 4H.626.15.0.00 , Bracket: Alternator Mounts Cart Part No 4H.641.03.0.00 , Hose: Air Cleaner Cart Part No 4H.643.01.0.00 , Fuel Pump: 4R1040pg Cart Part No 4H.652.10.0.00 , Expansion Bellow Cart Part No 4H.655.01.0.00 , Set Of Joints Cart Part No 4H.656.03.0.Sp , Set Of Oring (For 4H.2416/4H.3421/4H.3521 Cart Part No 4H.656.23.0.00 , Set Of Copper / Rubber Washer Cart Part No 4H.656.53.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 4H.657.01.0.00 , Header For L.O.C & Filter S/F Water Jacket Heater Cart Part No 4H.658.01.0.00 , Bracket For Water Separator Cart Part No 4H.665.01.0.00 , Push Button ( For Heater) Cart Part No 4H.671.02.0.00 , Thermostat And Housing Assembly Cart Part No 4H.673.10.0.00 , Flywheel Housing Cart Part No 4H.682.01.0.00 , Blanking Plate For Starter Bore Cart Part No 4H.682.02.0.00 , Flange For Starter Cart Part No 4H.682.03.0.00 , Flywheel Housing Cart Part No 4H.682.04.0.00 , Starter Ring Cart Part No 4H.683.01.0.00 , Exhaust Manifold (Fwe Top Open) Cart Part No 4H.685.11.0.00 , Air Pipe(Turbo To Inlet Pipe) Cart Part No 4H.686.12.0.00 , Assly Lube Oil Inlet Pipe: K24 Tc Cart Part No 4H.687.50.0.00 , Lube Oil Drain Pipe Cart Part No 4H.687.60.0.00 , V Belt Xpa 1280 Cart Part No 4H.692.01.0.00 , V Belt Spa X 1280 X 2 Pair Cart Part No 4H.692.02.0.00 , V Belt: Spa 1300Ar Armide Wrap Cart Part No 4H.692.03.0.00 , Eye Bolt : Dia 12X 220 Long Cart Part No 4H.703.07.0.00 , Eye Bolt (Dia.12 X 220 Length) Cart Part No 4H.703.15.0.Pr , Bracket For Accelerator Cable Cart Part No 4H.715.01.0.00 , Adaptorfor Solenoid Cart Part No 4H.719.12.0.Pr , Leak Off Pipe Assembly Cart Part No 4H.719.20.0.00 , Elect Rpm Cum Hour Meter 24V Sf 172 Pcd C Pulley 90 Pcd Alt Pulley 12 Pole Altr Cart Part No 4H.723.01.0.00 , Fuel Pipe (90,14X14b-90 Deg, 700 Wb) Cart Part No 4H.739.03.0.00 , Fuel Pipe: 7.5 14X14b-90 Deg520 Wb Cart Part No 4H.739.04.0.00 , Recovery Tank With Pipe:4Rta Cart Part No 4H.760.03.0.00 , Stay Rod: Radiator Cart Part No 4H.761.02.0.00 , Aluminium Radiator Assembly Cart Part No 4H.761.95.0.Pr , Recovery Tank With Pipe (For 2R To 4R Radiators) Cart Part No 4H.762.03.0.00 , Exhaust Manifold Cart Part No 4H.763.02.0.00 , Air Pipe Tc To Inlet Mfold Cart Part No 4H.764.11.0.00 , Lube Oil Inlet Pipe Cart Part No 4H.765.02.0.Pr , Platefor Turbo Oil In Pipe Cart Part No 4H.765.03.0.Pr , Assly Lube Oil Inlet Pipe Cart Part No 4H.765.50.0.00 , L O Drain Arrangement For K24 Vs Turboterex Vectra Cart Part No 4H.765.60.0.00 , Leak Off Pipe Assembly Cart Part No 4H.769.10.0.00 , Leak Off Pipe Assly Cart Part No 4H.769.20.0.00 , Hose: Air Cleaner Cart Part No 4H.774.04.0.00 , Flange (At Silencer Inlet & Outlet) For 4R1040,4R1040t Silent Set Cart Part No 4H.775.04.0.00 , Residential Silencer For 62 5 Kva Cart Part No 4H.777.01.0.00 , Adaptor (5/8 Inch Unf X M14) Cart Part No 4H.779.01.0.00 , Thermostat & Hsg Assly Cart Part No 4H.779.10.0.00 , Thermostat And Hsg Assembly Cart Part No 4H.779.20.0.00 , Thermostat And Housing (1/2Npt-M14 Housing, 90Deg Bend Cover To Fip Side) Cart Part No 4H.779.60.0.00 , Thermostat And Hsg Assembly Cart Part No 4H.779.80.0.00 , Gear End Foot Cart Part No 4H.781.01.0.00 , Gear End Foot Cart Part No 4H.781.02.0.00 , Nylock Nut For Jcb Loging (M8x1.25) Cart Part No 4H.781.11.0.00 , Nylock Nut(M14x 2) Cart Part No 4H.781.13.0.00 , Drain Pipe For Lube Oil Sump Cart Part No 4H.790.07.0.00 , Hose: Air Cleaner Cart Part No 4H.791.03.0.00 , Exhaust Silencer Cart Part No 4H.792.40.0.00 , Exhaust Silencer Set: 82.5Kva Cart Part No 4H.792.50.0.00 , Exhaust Silencer Cart Part No 4H.792.60.0.00 , Exhaust Manifold (Ge, Top Open) Cart Part No 4H.793.11.0.00 , Flexible Rubber Coupling Cart Part No 4H.807.06.0.Pr , Sae 2De Brkt- Prot. Screen Asly -Kg34. Kva Rating:- (45-62.5, 1Ph & 82.5-160, 3Ph) Cart Part No 4H.837.03.0.Asp , Excitor Stator Kg34 H=55Mm 8P. Kva Rating:- (45-62.5, 1Ph & Cart Part No 4H.837.04.0.Asp , Exciter Rotor Cart Part No 4H.837.05.0.Asp , Fan Assembly Kg34kva Rating45 62 51Ph Cart Part No 4H.837.06.0.Asp , Drain Pipe For Lub Oil Sump Cart Part No 4H.844.02.0.00 , Emergency Push Stop Button Cart Part No 4H.851.02.0.00 , Emergency Stop Push Button Tunr To Relesenc Elment Cart Part No 4H.851.11.0.00 , Power Terminal Board Cart Part No 4H.863.14.0.00 , Relay Board Cart Part No 4H.864.02.0.00 , Relay Board: 4 Relay Cart Part No 4H.865.01.0.00 , Fuse Holder With Fuse Blown Indicator Cart Part No 4H.865.08.0.00 , Glass Fuse 2Amp20 Mm Cart Part No 4H.865.09.0.00 , Single Pole Mcb 32A Cart Part No 4H.865.16.0.00 , Selector Switch Cart Part No 4H.865.17.0.00 , Control Terminal 6 Sq.Mm,600V,50A,Type Cart Part No 4H.865.22.0.00 , Power Terminal Board 125 Amp.4 Way 8 Mm Stud Cart Part No 4H.865.23.0.00 , Relay Board 2 & 1/2 12V Dc Cart Part No 4H.865.27.0.00 , Relay Board (4 Relay ) Contact Raiting 5 Amp.12 V Dc 1 C/Owith Relay. Cart Part No 4H.865.33.0.00 , Earthing Cable (Braded) 6Mm Dia. With Suitable Lug. Alt. To Base Plate For50 & 72 Cart Part No 4H.872.03.0.00 , Mccb 200A,3 Pole Cart Part No 4H.873.01.0.00 , Battery Charger - 6A 12V Cart Part No 4H.878.07.0.00 , 2A Electrical Charger Cart Part No 4H.878.12.0.00 , 12V, 2A, Battery Charger, 15Kv Common Mode Surge Isolation Cart Part No 4H.878.14.0.Pr , Egt Inlet Outlet Joint Cart Part No 4H.881.01.0.Pr , Ad Blue Tank Clamp (25Lits) Cart Part No 4H.881.03.0.Pr , Vdo Sensor Assembly Cart Part No 4H.890.40.0.00 , Fuel Pipe: M14xm14b Parallel 750L Cart Part No 4H.896.07.0.00 , Fuel Pipe: M14xm14 Banjo With 60 Deg, 370 L, 9.5 Id Cart Part No 4H.896.08.0.00 , Fuel Pipe Inlet: M14xm14 Banjo Both Side 900L Cart Part No 4H.896.09.0.00 , Spacer For Air Cleaner Bracket (Od 20X Id 9 X L 39) Cart Part No 4H.899.02.0.00 , Hose: Air Cleaner Cart Part No 4H.899.03.0.00 , Sleeve For Air Cleaner Hose Cart Part No 4H.899.04.0.00 , Rubber Hose: K24 Tc Cart Part No 4H.899.11.0.00 , Engine Wiring Harness Assembly For Paver Application Bsiii Cart Part No 4H.900.30.0.00 , Koel Green Alternatorkg 125 S T Framel Kg 44 3 Dsae 2 11 5 415V50 Hz0 8 Pf Cart Part No 4H.901.05.0.Pr , Koel Green Alternatorcoastalhumid Environment Kg 125 S T Framekg 44 3 D1 Cart Part No 4H.901.08.0.Pr , Koel Green Alternator40kva Kg32 1L4css Frame Msae 3 Vol 11 5230V50hz0 8 P Cart Part No 4H.901.11.0.Pr , Koel Green Alternator40kva St Frame Mkg32 2S4csae3 Vol 11 5415V50hz 0 8 P Cart Part No 4H.901.12.0.Pr , Koel Green Alternator, 45Kva, St Frame:M, Kg32 2S4c, Sae3 Vol 11.5, 415V, 50Hz, 0.8 P. Cart Part No 4H.901.14.0.Pr , Wiring Harness: 4R1040 Cart Part No 4H.905.20.0.00 , Relay 12Vdc100a Model Bgr 256 Cart Part No 4H.906.11.0.00 , Wiring Harness Assembly 4R1040ta Cart Part No 4H.906.70.0.00 , Coolant Temp Switch 95 +1/-3 Deg Cart Part No 4H.907.01.0.00 , Coolant Temp Switch 1041 3 Deg Cart Part No 4H.907.03.0.00 , Wiring Harness Assembly For Kpcl With Etr Type Sol. Cart Part No 4H.924.30.0.00 , Injector Cart Part No 4H.933.02.0.00 , Injector Cart Part No 4H.933.04.0.00 , Fuel Injection Pump 4R1040na Engine (76Hp @ 2200Rpm) Cart Part No 4H.933.10.0.00 , Fuel Injection Pump For 4R1040na49 Hp 2200 Rpmwith Stop Leverbs Iii Industrial Cart Part No 4H.933.35.0.Pr , Lube Oil Sump Fabricated (35 Deg, 265 Ht, Drain Plug On Fwe & Ge Both)) Cart Part No 4H.940.01.0.00 , Lub Oil Sump Fabricated (30 Deg S/F Jcb Vmt 850 ) Cart Part No 4H.940.02.0.00 , Sub Assembly Of Suction Tube Cart Part No 4H.941.10.0.00 , Cover Plate For Flywheel Housing Cart Part No 4H.944.02.0.00 , Flywheel Assembly Cart Part No 4H.947.10.0.00 , Flywheel Assembly Cart Part No 4H.947.20.0.00 , Washer For Weld Stud M5 Cart Part No 4H.948.96.0.00 , Crankpulley Holding Spanner Cart Part No 4H.950.04.0.00 , Lseries 43Mm Integrated Mixer With Throttle Body Cart Part No 4H.956.03.0.00 , Communication Cable L Series Rs232 Communications Assembly Cart Part No 4H.956.032.0.Sp , Spark Plug : Size M12 Cart Part No 4H.956.05.0.00 , 26941102 A Lucas Distributor Cart Part No 4H.956.12.0.00 , Ht Cable Set Cart Part No 4H.956.13.0.00 , Distributor Ignition Coil 26941094A Cart Part No 4H.956.15.0.00 , R 600Z Zpr Zero Pressure Regulator Cart Part No 4H.956.39.0.00 , Sealed Ball Bearing: Deep Groove Single Row Cart Part No 4H.956.44.0.00 , Gasket For L-Series Governor Mounting Cart Part No 4H.956.59.0.00 , Pipe G I Braided1 5 Meter Long For The Gas Supply From The Solenoid Valve To Ze Cart Part No 4H.956.83.0.00 , Adaptor 1Bsp To 3 4Bsp Cart Part No 4H.956.84.0.00 , L-Series (25Mm) Integrated Mixer With Throttle Body(8404- Cart Part No 4H.956.98.0.00 , Timing Pointer Cart Part No 4H.964.01.0.00 , Set Bolt M8 ( Rolled Brass) For Panel Earthing Cart Part No 4H.971.18.0.00 , M8 Nut Rolled Brass For Panel Earthing Shanti Project Cart Part No 4H.971.19.0.00 , M8 Brass Washer For Panel Earthing Cart Part No 4H.971.23.0.00 , Expansion Bellow Cart Part No 4H.973.10.0.00 , Canopy Wiring Harness For 125Kva 4K Cpcb4+ Cart Part No 4H.978.80.0.Pr , Breather Pipe Cart Part No 4H.979.06.0.00 , B12 Ecu 40Kva Appl Cart Part No 4H.985.12.0.00 , Wiring Harness Assly: Cpcb Cart Part No 4H.986.20.0.00 , Battery Cable 50 Sq Mm For 24V System Cart Part No 4H.996.20.0.Pr , Cambush Pressing Tool Cart Part No 4H.998.32.0.Tol , Core Plug Pressing Tool Cart Part No 4H.998.33.0.Tol , Deflector Plate Guide Cart Part No 4H.998.34.0.Tol , Nozzle Puller Cart Part No 4H.998.35.0.Tol , Piston Guide Cart Part No 4H.998.36.0.Tol , Stem Seal Cart Part No 4H.998.37.0.Tol , Valve Spring Tool Cart Part No 4H.998.38.0.Tol , Oil Seal Fwe Tool Cart Part No 4H.998.39.0.Tol , Liner Installation Tool Cart Part No 4H.998.40.0.Tol , Core Plug 52Mm No Cart Part No 4H.998.41.0.Tol , Liner Puller Original No Cart Part No 4H.998.42.0.Tol , Gear End Oil Seal Mandril No Cart Part No 4H.998.43.0.Tol , Wet Pm Kit (W/O Oil) For 4H.2401... - 4R1040t Cart Part No 4H.999.09.0.Sp , Cold Start Kit L3 For 4K Cart Part No 4H.999.120.0.00 , Wet Pm Kit (W/O Oil) For 4H.3501 - 4R1080 Cart Part No 4H.999.13.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3445 - 4R1040t Cart Part No 4H.999.16.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3523,4H.3545,4H.3555,4H.3558, 4H.8905, 4H.8932- 4R1040ta G1 Cart Part No 4H.999.19.0.Sp , Wet Pm Kit (W/O Oil) For 4H.6001,4H.7902 - 4K 1080Ta Cart Part No 4H.999.21.0.Sp , Wet Pm Kit (W/O Oil) For 4H.7922 - 4K1080ta G2 Cart Part No 4H.999.24.0.Sp , Set Of Joints Cart Part No 4H.999.30.0.Sp , 4R1040 Cpcb Ii Service Kit - B Check Cart Part No 4H.999.35.0.00 , 4R1040 Cpcb Ii Service Kit With Air Filter - C Check Cart Part No 4H.999.36.0.00 , Wet Pm Kit (W/O Oil) For 4H.5001, 4H.5006 - 4R1080 Cart Part No 4H.999.37.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3045,4H.3048- 4R1040 Cart Part No 4H.999.47.0.Sp , Half Overhaul Kit 4R1040 Indl Cart Part No 4H.999.50.0.00 , Wet Pm Kit (W/O Oil) For 4H.3023, 4H.3017, 4H.3002, 4H.2002- 4R1040 Cart Part No 4H.999.54.0.Sp , Major Overhaul Kit 4R1040 Bsiii Cat, Cnh, Ecel, Ace, Atlas Application Engines Cart Part No 4H.999.60.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3420, 4H.3401- 4R1040t Cart Part No 4H.999.61.0.Sp , Wet Pm Kit (W/O Oil ) For 4H.8041 Cart Part No 4H.999.62.0.Sp , Wet Pm Kit (W/O Oil) For 4H.3031, 4H.3025 - 4R1040 Cart Part No 4H.999.64.0.Sp , Major Oh Kit 4R1040 Bsiii Terex, Apollo, Ecel, Ajax Application Engines Cart Part No 4H.999.70.0.Sp , Solenoid Valve S-0106 Cart Part No 4H.999.71.0.Sp , Pressure Regulator First Level For 62.5 Kva (R 4601) Cart Part No 4H.999.73.0.Sp , Zpr 1 Bsp (F) (R 6301) Cart Part No 4H.999.74.0.Sp , Wet Pm Kit (W/O Oil) For 4H.2501 - 4R1040 Ta Cart Part No 4H.999.75.0.Sp , Wet Pm Kit (W/O Oil) For 4H.7901, 4H.7902, 4H.7905 - 4K1080ta G2 Cart Part No 4H.999.76.0.Sp , Service Kit 500 Hrs: 4R1040 Bsiii Indl Cart Part No 4H.999.80.0.00 , Air Filter Kit A-4R1040 Bs3 Indl Cart Part No 4H.999.85.0.00 , Air Filter Kit B -4R1040 Bs3 Indl Cart Part No 4H.999.90.0.00 , Doc Catalyst (7.5 Dia X 5 Length, 15 G/Cft, 5/1 Pt:Pd, Fresh) Cart Part No 4H.Egt4.10.0.Pr , Scr Catalyst First Brick - Fresh (7.5 Dia X 7 Length, Wcl 2.5 G/In3) Cart Part No 4H.Egt4.14.0.Pr , Scr Catalyst Second Brick - Fresh (7.5 Dia X 7 Length, 2.1 G/In3 On 5” Length, Asc 2 Cart Part No 4H.Egt4.16.0.Pr , 7.5 V Band Clamp (Docto Mixer)_82601021 Cart Part No 4H.Egt4.21.0.Pr , 7 5Gasket Doc To Mixer 82544598 Cart Part No 4H.Egt4.22.0.Pr , Dosing Module B444 606 505Dm2 2 3 Hole5 Bar Cart Part No 4H.Egt4.23.0.Pr , Adblue Levelquality Temp Sensor For 25 Ltr Tank Cart Part No 4H.Egt4.26.0.Pr , 7.5 Egt System Assembly (Cpcb 4+ ) Cart Part No 4H.Egt4.61.0.Sp , Buzzerwithlamp,12Vac/Dc Cart Part No 4H.M821.26.0.Pr , Split Cotter Pin 3 2X22 Cart Part No 50.001.04.022. , Set Bolt - M5x0.8X25- 8.8 Cart Part No 50.002.05.025. , Set Bolt - M6x1x35 - 8.8 Cart Part No 50.002.06.035. , Set Bolt - M6x1x40 - 8.8 Cart Part No 50.002.06.040. , Set Bolt - M6x1x50 - 8.8 Cart Part No 50.002.06.050. , Set Bolt M6x1x60 8 8 Cart Part No 50.002.06.060. , Set Bolt - M8x1.25X16 - 8.8 Cart Part No 50.002.08.016. , Set Bolt - M8x1.25X25 - 8.8 Cart Part No 50.002.08.025. , Set Bolt - M8x1.25X30 - 8.8 Cart Part No 50.002.08.030. , Set Bolt : M8x1.25X35 -8.8 Cart Part No 50.002.08.035. , Set Bolt - M8x1.25X40 - 8.8 Cart Part No 50.002.08.040. , Set Bolt : M8x1.25X45 - 8.8 Cart Part No 50.002.08.045. , Set Bolt - M8x1.25X50 - 8.8 Cart Part No 50.002.08.050. , Set Bolt - M8x1.25X55 - 8.8 Cart Part No 50.002.08.055. , Set Bolt - M8x1.25X60 - 8.8 Cart Part No 50.002.08.060. , Set Bolt - M8x1.25X65 - 8.8 Cart Part No 50.002.08.065. , Set Bolt: M8x1.25X70 -8.8 Cart Part No 50.002.08.070. , Set Bolt - M8x1.25X75 - 8.8 Cart Part No 50.002.08.075. , Set Bolt - M8x1.25X80 - 8.8 Cart Part No 50.002.08.080. , Set Bolt - M8x1.25X85 - 8.8 Cart Part No 50.002.08.085. , Set Bolt - M8x1.25X90 - 8.8 Cart Part No 50.002.08.090. , Set Bolt - M8x1.25X95 - 8.8 Cart Part No 50.002.08.095. , Set Bolt: M8x1.25X100 -8.8 Cart Part No 50.002.08.100. , Set Bolt - M8x1.25X105 - 8.8 Cart Part No 50.002.08.105. , Set Bolt - M8x1.25X110 - 8.8 Cart Part No 50.002.08.110. , Set Bolt - M8x1.25X115 - 8.8 Cart Part No 50.002.08.115. , Set Bolt - M8x1.25X120 - 8.8 Cart Part No 50.002.08.120. , Set Bolt - M8x1.25X125 - 8.8 Cart Part No 50.002.08.125. , Hexagonal Headed Bolt - M8 X 130L Cart Part No 50.002.08.130. , Set Bolt - M8x1.25X140 - 8.8 Cart Part No 50.002.08.140. , Set Bolt M8x1 25X150 8 8 Cart Part No 50.002.08.150. , Set Bolt - M10x1.5X20 - 8.8 Cart Part No 50.002.10.020. , Set Bolt - M10x1.5X25 - 8.8 Cart Part No 50.002.10.025. , Set Bolt - M10x1.5X30 - 8.8 Cart Part No 50.002.10.030. , Set Bolt - M10x1.5X35 - 8.8 Cart Part No 50.002.10.035. , Set Bolt - M10x1.5X40 - 8.8 Cart Part No 50.002.10.040. , Set Bolt - M10x1.5X45 - 8.8 Cart Part No 50.002.10.045. , Set Bolt - M10x1.5X50 - 8.8 Cart Part No 50.002.10.050. , Set Bolt - M10x1.5X55 - 8.8 Cart Part No 50.002.10.055. , Set Bolt - M10x1.5X60 - 8.8 Cart Part No 50.002.10.060. , Set Bolt - M10x1.5X65 - 8.8 Cart Part No 50.002.10.065. , Set Bolt - M10x1.5X70 - 8.8 Cart Part No 50.002.10.070. , Set Bolt - M10x1.5X75 - 8.8 Cart Part No 50.002.10.075. , Set Bolt - M10x1.5X80 - 8.8 Cart Part No 50.002.10.080. , Set Bolt - M10x1.5X85 - 8.8 Cart Part No 50.002.10.085. , Set Bolt - M10x1.5X90 - 8.8 Cart Part No 50.002.10.090. , Set Bolt - M10x1.5X100 - 8.8 Cart Part No 50.002.10.100. , Set Bolt - M10x1.5X110 - 8.8 Cart Part No 50.002.10.110. , Set Bolt - M10x1.5X115 - 8.8 Cart Part No 50.002.10.115. , Set Bolt - M10x1.5X120 - 8.8 Cart Part No 50.002.10.120. , Set Bolt - M10x1.5X125 - 8.8 Cart Part No 50.002.10.125. , Set Bolt - M10x1.5X130 - 8.8 Cart Part No 50.002.10.130. , Set Bolt - M10x1.5X140 - 8.8 Cart Part No 50.002.10.140. , Set Bolt - M10x1.5X150 - 8.8 Cart Part No 50.002.10.150. , Set Bolt : M10x1.5X160 -8.8 Cart Part No 50.002.10.160. , Set Bolt - M12x1.75X30 - 8.8 Cart Part No 50.002.12.030. , Set Bolt M12x1 75X35 8 8 Cart Part No 50.002.12.035. , Set Bolt - M12x1.75X40 - 8.8 Cart Part No 50.002.12.040. , Set Bolt - M12x1.75X45 - 8.8 Cart Part No 50.002.12.045. , Set Bolt - M12x1.75X50 - 8.8 Cart Part No 50.002.12.050. , Set Bolt - M12x1.75X55 - 8.8 Cart Part No 50.002.12.055. , Set Bolt - M12x1.75X60 - 8.8 Cart Part No 50.002.12.060. , Set Bolt - M12x1.75X65 - 8.8 Cart Part No 50.002.12.065. , Set Bolt - M12x1.75X70 - 8.8 Cart Part No 50.002.12.070. , Set Bolt - M12x1.75X90 - 8.8 Cart Part No 50.002.12.090. , Set Bolt - M12x1.75X100 - 8.8 Cart Part No 50.002.12.100. , Set Bolt M12x1 75X120 8 8 Cart Part No 50.002.12.120. , Set Bolt M12x1 75X125 8 8 Cart Part No 50.002.12.125. , Set Bolt - M12x1.75X150 - 8.8 Cart Part No 50.002.12.150. , Set Bolt - M12x1.75X160 - 8.8 Cart Part No 50.002.12.160. , Set Bolt - M12x1.75X200 - 8.8 Cart Part No 50.002.12.200. , Set Bolt - M14x2x45 - 8.8 Cart Part No 50.002.14.045. , Set Bolt - M14x2x50 - 8.8 Cart Part No 50.002.14.050. , Set Bolt - M14x2x60 - 8.8 Cart Part No 50.002.14.060. , Set Bolt M14 X 75 Cart Part No 50.002.14.075. , Set Bolt - M16x2x40 - 8.8 Cart Part No 50.002.16.040. , Set Bolt - M16x2x45 - 8.8 Cart Part No 50.002.16.045. , Set Bolt - M16x2x50 - 8.8 Cart Part No 50.002.16.050. , Set Bolt - M20x2.5X60 - 8.8 Cart Part No 50.002.20.060. , Set Bolt - M20x2.5X70 - 8.8 Cart Part No 50.002.20.070. , Set Bolt - M20x2.5X75 - 8.8 Cart Part No 50.002.20.075. , Hexagonal Headed Bolt - M4 X 12L Cart Part No 50.003.04.012. , Hexagonal Headed Bolt - M4 X 16L Cart Part No 50.003.04.016. , Set Screw - M5x0.8X10 - 8.8 Cart Part No 50.003.05.010. , Screw M5 X 16 Mm Cart Part No 50.003.05.016. , Set Screw - M5x0.8X20 - 8.8 Cart Part No 50.003.05.020. , Set Screw - M6x1x10 - 8.8 Cart Part No 50.003.06.010. , Set Screw: M6x1x12 -8.8 Cart Part No 50.003.06.012. , Set Screw - M6x1x14 - 8.8 Cart Part No 50.003.06.014. , Set Screw - M6x1x15 - 8.8 Cart Part No 50.003.06.015. , Set Screw: M6x1x16 -8.8 Cart Part No 50.003.06.016. , Set Screw M6x1x18 8 8 Cart Part No 50.003.06.018. , Set Screw - M6x1x20 - 8.8 Cart Part No 50.003.06.020. , Set Screw Cart Part No 50.003.06.022. , Set Screw - M6x1x25 - 8.8 Cart Part No 50.003.06.025. , Set Screw - M6x1x30 - 8.8 Cart Part No 50.003.06.030. , Set Screw - M6x1x35 - 8.8 Cart Part No 50.003.06.035. , Set Screw - M6x1x40 - 8.8 Cart Part No 50.003.06.040. , Set Screw Cart Part No 50.003.06.045. , Set Screw - M6x1x50 - 8.8 Cart Part No 50.003.06.050. , Set Screw - M6 X O60 Long Cart Part No 50.003.06.060. , Set Screw - M8x1.25X10 - 8.8 Cart Part No 50.003.08.010. , Set Screw - M8x1.25X14 - 8.8 Cart Part No 50.003.08.014. , Set Screw - M8x1.25X15 - 8.8 Cart Part No 50.003.08.015. , Set Screw: M8x1.25X16 -8.8 Cart Part No 50.003.08.016. , Set Screw - M8x1.25X18 - 8.8 Cart Part No 50.003.08.018. , Set Screw: M8x1.25X20 -8.8 Cart Part No 50.003.08.020. , Set Screw - M8x1.25X22 - 8.8 Cart Part No 50.003.08.022. , Set Screw: M8x1.25-8.8 Cart Part No 50.003.08.025. , Set Screw: M8x1.25X30-8.8 Cart Part No 50.003.08.030. , Set Screw - M8x1.25X35 - 8.8 Cart Part No 50.003.08.035. , Set Screw M8x1 25X40 8 8 Cart Part No 50.003.08.040. , Set Screw - M8x1.25X45 - 8.8 Cart Part No 50.003.08.045. , Set Screw - M8x1.25X50 - 8.8 Cart Part No 50.003.08.050. , Set Screw - M8x1.25X55 - 8.8 Cart Part No 50.003.08.055. , Set Screw M8x1.25X60 Cart Part No 50.003.08.060. , Set Screw Cart Part No 50.003.08.080. , Set Screw - M10x1.5X15 - 8.8 Cart Part No 50.003.10.015. , Set Screw: M10x1.5X20 -8.8 Cart Part No 50.003.10.020. , Set Screw: M10x1.5X25 -8.8 Cart Part No 50.003.10.025. , Set Screw: M10x1.5X30 -8.8 Cart Part No 50.003.10.030. , Set Screw: M10x1.5X35 -8.8 Cart Part No 50.003.10.035. , Set Screw - M10x1.5X40 - 8.8 Cart Part No 50.003.10.040. , Set Screw - M10x1.5X45 - 8.8 Cart Part No 50.003.10.045. , Set Screw - M10x1.5X50 - 8.8 Cart Part No 50.003.10.050. , Set Screw - M10x1.5X55 - 8.8 Cart Part No 50.003.10.055. , Set Screw - M10x1.5X70 - 8.8 Cart Part No 50.003.10.070. , Set Screw - M12x1.75X20 - 8.8 Cart Part No 50.003.12.020. , Set Screw - M12x1.75X25 - 8.8 Cart Part No 50.003.12.025. , Set Screw - M12x1.75X30 - 8.8 Cart Part No 50.003.12.030. , Set Screw - M12x1.75X35 - 8.8 Cart Part No 50.003.12.035. , Set Screw - M12x1.75X40 - 8.8 Cart Part No 50.003.12.040. , Set Screw - M12x1.75X45 - 8.8 Cart Part No 50.003.12.045. , Set Screw - M12x1.75X50 - 8.8 Cart Part No 50.003.12.050. , Set Screw - M12x1.75X55 - 8.8 Cart Part No 50.003.12.055. , Set Screw Cart Part No 50.003.12.060. , Set Screw M14x2x30 8 8 Cart Part No 50.003.14.030. , Set Screw M14x2x35 8 8 Cart Part No 50.003.14.035. , Set Screw - M14x2x40 - 8.8 Cart Part No 50.003.14.040. , Set Screw - M14x2x50 - 8.8 Cart Part No 50.003.14.050. , Set Screw - M14x2x55 - 8.8 Cart Part No 50.003.14.055. , Set Screw - M16x2x40 - 8.8 Cart Part No 50.003.16.040. , Set Screw - M16x2x50 - 8.8 Cart Part No 50.003.16.050. , Set Screw - M20x2.5X50 - 8.8 Cart Part No 50.003.20.050. , Set Screw - M20x2.5X60 - 8.8 Cart Part No 50.003.20.060. , Nut - M4x0.7 - Gr.8.8 Cart Part No 50.006.04.000. , Nut - M5x0.8 - Gr.8.8 Cart Part No 50.006.05.000. , Nut: M6x1 - Gr8 Cart Part No 50.006.06.000. , Nut M8x1.25 -Gr8 Cart Part No 50.006.08.000. , Nut : M10x1.5 -Gr8 Cart Part No 50.006.10.000. , Nut: M12x1.75 - Gr8 Cart Part No 50.006.12.000. , Nut - M14x2 - Gr.8.8 Cart Part No 50.006.14.000. , Nut - M16x2 - Gr.8.8 Cart Part No 50.006.16.000. , Nut M18x2 5 Gr 8 8 Cart Part No 50.006.18.000. , Nut - M20x2.5 - Gr.8 Cart Part No 50.006.20.000. , Nut M8x1 Gr 8 Cart Part No 50.007.08.000. , Nut - M16x1.5 - Gr.8 Cart Part No 50.007.16.000. , Lock Nut - M6x1 - Gr.8 Cart Part No 50.008.06.000. , Lock Nut - M10x1.5 - Gr.8 Cart Part No 50.008.10.000. , Nut Cart Part No 50.009.10.000. , Lock Nut - M14x1.5 - Gr.8 Cart Part No 50.009.14.000. , Lock Nut 20X1.5 Cart Part No 50.009.20.000. , Stud - M6x1x16 - 8.8 Cart Part No 50.010.06.016. , Stud - M6x1x20 - 8.8 Cart Part No 50.010.06.020. , Stud - M6x1x35- 8.8 Cart Part No 50.010.06.035. , Stud - M8x1.25X16 - 8.8 Cart Part No 50.010.08.016. , Stud - M8x1.25X20 - 8.8 Cart Part No 50.010.08.020. , Stud: M8x1.25X25 - 8.8 Cart Part No 50.010.08.025. , Stud -M8x 1.25X30 -8.8 Cart Part No 50.010.08.030. , Stud: M8x1.25X35 -8.8 Cart Part No 50.010.08.035. , Stud-M8x1.25X40 -8.8 Cart Part No 50.010.08.040. , Stud: M8x1.25X45 -8.8 Cart Part No 50.010.08.045. , Stud: M8x1.25X50 - 8.8 Cart Part No 50.010.08.050. , Stud-M8x1.25X55 -8.8 Cart Part No 50.010.08.055. , Stud: M8x1.25X60 - 8.8 Cart Part No 50.010.08.060. , Stud- M8 X1.25 X 65 Mm - 8.8 Grade Cart Part No 50.010.08.065. , Stud: M8x1.25X75 - 8.8 Cart Part No 50.010.08.075. , Stud - M8x1.25X80 - 8.8 Cart Part No 50.010.08.080. , Stud - M8x1.25X85 - 8.8 Cart Part No 50.010.08.085. , Stud M8x1.25X090 Gr. 8.8 Cart Part No 50.010.08.090. , Stud - M8x1.25X95 - 8.8 Cart Part No 50.010.08.095. , Stud Cart Part No 50.010.08.100. , Stud: M10x1.5X25 - 8.8 Cart Part No 50.010.10.025. , Stud-M8x1.25X55 -8.8 Cart Part No 50.010.10.030. , Stud: M10x1.5X35 - 8.8 Cart Part No 50.010.10.035. , Stud: M10x1.5X45 -8.8 Cart Part No 50.010.10.045. , Stud: M10x1.5X50 - 8.8 Cart Part No 50.010.10.050. , Stud - M10x1.5X60 - 8.8 Cart Part No 50.010.10.060. , Stud - M10x1.5X65 - 8.8 Cart Part No 50.010.10.065. , Stud - M10x1.5X70 - 8.8 Cart Part No 50.010.10.070. , Stud: M10x1.5X75 - 8.8 Cart Part No 50.010.10.075. , Stud Cart Part No 50.010.10.110. , Stud M12x1 75X25 8 8 Cart Part No 50.010.12.025. , Stud - M12x1.75X30 - 8.8 Cart Part No 50.010.12.030. , Stud Cart Part No 50.010.12.150. , Stud - M12x1.75X200 - 8.8 Cart Part No 50.010.12.200. , Socket Head Screw - M6x1x14 - 8.8 Cart Part No 50.011.06.014. , Socket Head Screw - M6x1x16 - 8.8 Cart Part No 50.011.06.016. , Socket Head Screw - M6x1x20 - 8.8 Cart Part No 50.011.06.020. , Socket Head Screw - M6x1x25 - 8.8 Cart Part No 50.011.06.025. , Socket Head Screw M6x1x30 Cart Part No 50.011.06.030. , Socket Head Screw: M8x1.25X16-8.8 Cart Part No 50.011.08.016. , Socket Head Screw M8x1.25X20 -8.8 Cart Part No 50.011.08.020. , Socket Head Screw - M8x1.25X25 - 8.8 Cart Part No 50.011.08.025. , Socket Head Screw - M8x1.25X30 - 8.8 Cart Part No 50.011.08.030. , Socket Head Screw - M8x1.25X35 - 8.8 Cart Part No 50.011.08.035. , Socket Head Screw - M8x1.25X40 - 8.8 Cart Part No 50.011.08.040. , Socket Head Screw M8x1 25X45 8 8 Cart Part No 50.011.08.045. , Socket Head Cap Bolt(M8x50 Long) Cart Part No 50.011.08.050. , Socket Head Screw - M8x1.25X55 - 8.8 Cart Part No 50.011.08.055. , Socket Head Cap Bolt M8x60 Lg Cart Part No 50.011.08.060. , Socket Head Screw - M8x1.25X70 - 8.8 Cart Part No 50.011.08.070. , Socket Head Screw: M8x1.25X75-8.8 Cart Part No 50.011.08.075. , Socket Head Screw - M8x1.25X90 - 8.8 Cart Part No 50.011.08.090. , Socket Head Screw - M10x1.5X20 - 8.8 Cart Part No 50.011.10.020. , Socket Head Screw - M10x1.5X25 - 8.8 Cart Part No 50.011.10.025. , Socket Head Screw - M10x1.5X30 - 8.8 Cart Part No 50.011.10.030. , Socket Head Screw M10x1 5X35 8 8 Cart Part No 50.011.10.035. , Socket Head Screw - M10x1.5X40 - 8.8 Cart Part No 50.011.10.040. , Socket Head Screw - M10x1.5X50 - 8.8 Cart Part No 50.011.10.050. , Socket Head Screw - M10x1.5X120 - 8.8 Cart Part No 50.011.10.120. , Socket Head Screw - M12x1.75X40 - 8.8 Cart Part No 50.011.12.040. , Set Bolt - 5/16 Inch Bsfx2 Inch Long - 8.8 Cart Part No 50.013.02.014. , Set Bolt - 5/16 Inch Bsfx2-3/4 Inch Long - 8.8 Cart Part No 50.013.02.017. , Set Bolt - 5/16 Inch Bsfx3.0 Inch Long - 8.8 Cart Part No 50.013.02.018. , Set Bolt - 3/8Bsfx1-5/8L - 8.8 Cart Part No 50.013.03.012. , Set Screw - 5/16Bsfx5/8L - 8.8 Cart Part No 50.014.02.004. , Set Screw - 5/16Bsfx1L - 8.8 Cart Part No 50.014.02.007. , Set Screw - 5/16Bsfx1-1/2L - 8.8 Cart Part No 50.014.02.011. , Nut - 5/16 Bsf Normal Class - Grade P Cart Part No 50.015.02.000. , Lock Nut - 5/16Bsf Normal Class - Gr.P Cart Part No 50.016.02.000. , Lock Nut - 1/2Bsf Normal Class - Gr.P Cart Part No 50.016.05.000. , Socket Head Grub Screw Cart Part No 50.022.03.006. , Socket Head Grub Screw - M6 X 08 Cart Part No 50.022.06.008. , Slotted Cheese Head Screw - M3x16 Cart Part No 50.025.03.016. , Slotted Cheese Head Screw M5x15 Cart Part No 50.025.05.015. , Stud 5/16Bsfx1.1/8 Grade R Cart Part No 50.030.02.004. , Stud 5/16Bsfx1.1/2 Grade R Cart Part No 50.030.02.007. , Split Cotter Pin - 1/16X1/2 Cart Part No 50.036.03.001. , Split Cotter Pin - 1/8X1-1/2 Cart Part No 50.036.07.010. , Self Locking Nyloc Nut - M5 Cart Part No 50.037.05.000. , Self Locking Nyloc Nut - M6 Cart Part No 50.037.06.000. , Self Locking Nyloc Nut - M8 Cart Part No 50.037.08.000. , Self Locking Nyloc Nut - M16 Cart Part No 50.037.16.000. , Wing Nut M6 Cart Part No 50.047.05.000. , Screw Cart Part No 50.051.12.035. , Set Screw: M12x1.75X 50L - 10.9 Cart Part No 50.051.12.050. , Set Screw 10.9 Class Cart Part No 50.051.16.050. , Set Screw 10.9 Grade Cart Part No 50.051.16.070. , Set Bolt-M10x30-10.9 Cart Part No 50.052.10.030. , Set Bolt M10x35 10 9 Cart Part No 50.052.10.035. , Bolt 10X80 10.9 Grade Cart Part No 50.052.10.080. , Set Bolt-M12x30-10.9 Cart Part No 50.052.12.030. , Set Bolt: M12 X 45 - 10.9 Cart Part No 50.052.12.045. , Set Bolt-M12x65-10.9 Cart Part No 50.052.12.065. , Set Bolt M14gr.10.9 Cart Part No 50.052.14.045. , Set Bolt: M14 X 80 Cart Part No 50.052.14.080. , Set Bolt Cart Part No 50.052.14.100. , Set Bolt-M16x150-10.9 Cart Part No 50.052.16.150. , Set Bolt-M20x60-10.9 Cart Part No 50.052.20.060. , Headless Pipe Plug1/8-27 Nptf Cart Part No 50.056.02.000. , Headless Pipe Plug1/2-14 Nptf Cart Part No 50.056.06.000. , Headless Pipe Plug1-11.5 Nptf Cart Part No 50.056.08.000. , Allen Headed Bolt M4 X 35L Cart Part No 50.076.04.035. , Socket Head Cap Screw M5x020 12 9 Cart Part No 50.076.05.020. , Allen Screw Cart Part No 50.076.05.035. , Socket Head Cap Screw - M6x012 - 12.9 Cart Part No 50.076.06.012. , Socket Head Cap Screw M6x040 12 9 Cart Part No 50.076.06.040. , Allen Bolt M6 X 050 Cart Part No 50.076.06.050. , Chc Screw Cart Part No 50.076.08.030. , Allen Screw Cart Part No 50.076.08.040. , Socket Head Cap Screw M8x70 -12.9 Cart Part No 50.076.08.070. , Socket Head Cap Screw M8x90 -12.9 Cart Part No 50.076.08.090. , Allen Screw Cart Part No 50.076.10.020. , Socket Head Cap Screw-M10x25-12.9 Cart Part No 50.076.10.025. , Socket Head Cap Screw-M10x30-12.9 Cart Part No 50.076.10.030. , Socket Head Cap Screw M10x045 12 9 Cart Part No 50.076.10.045. , Socket Head Screw - M10x1.5X55 - 12.9 Cart Part No 50.076.10.055. , Socket Head Cap Screw-M10x60-12.9 Cart Part No 50.076.10.060. , Allen Screw M 10 X 70 Mm Cart Part No 50.076.10.070. , Socket Head Cap Screw M10x75 12 9 Cart Part No 50.076.10.075. , Socket Head Cap Screw-M16x35-12.9 Cart Part No 50.076.16.035. , Socket Head Screw (Din912 M16x50 -12.5) Cart Part No 50.076.16.050. , Socket Head Screwdin912 M16x7012 5 Cart Part No 50.076.16.070. , Allen Screw Cart Part No 50.076.16.090. , Nut (Ss) - M8x1.25 Cart Part No 50.080.08.000. , S.S. Nut M10-Aisi-304 Cart Part No 50.080.10.000. , Banjo One Sided Sf M18 Bolt - For 1/2 Rubber Hose. Cart Part No 50.085.12.000. , Oil Seal 32X45x6w21502 Cart Part No 50.302.36.000. , Dowel Pins Cart Part No 50.401.04.012. , Dowel Pin - Bar Cart Part No 50.401.05.010. , Dowel (5 X 10) Cart Part No 50.401.06.010. , Dowel Cart Part No 50.401.06.012. , Dowel Pin Cart Part No 50.401.06.014. , Dowel Pin Cart Part No 50.401.06.025. , Dowel Pin Cart Part No 50.401.07.012. , Dowel Pin 6X30 Cart Part No 50.401.07.030. , Dowel Cart Part No 50.401.08.012. , Dowel Cart Part No 50.401.08.014. , Dowel Pin Cart Part No 50.401.08.016. , Dowel Pin 8X25 Cart Part No 50.401.08.025. , Dowel Pin 8X45 Cart Part No 50.401.08.045. , Dowel Pin 8X60 Cart Part No 50.401.08.060. , Dowel Pin 8X65 Cart Part No 50.401.08.065. , Dowel Pin 10X20 Cart Part No 50.401.09.020. , Dowel Pin Cart Part No 50.401.10.030. , Key(Impeller) Cart Part No 50.402.06.014. , Woodruff Key (4 X 6.5) Cart Part No 50.405.10.000. , Woodruff Key Cart Part No 50.405.12.000. , Circlip External 15 Mm Cart Part No 50.501.15.000. , Circlip External : 16 Mm Cart Part No 50.501.16.000. , Circlip External - 20 Mm Cart Part No 50.501.20.000. , Circlip External - 25 Mm Cart Part No 50.501.25.000. , Circlip External - 30 Mm Cart Part No 50.501.30.000. , Circlip External - 35 Mm Cart Part No 50.501.35.000. , Circlip External - 40 Mm Cart Part No 50.501.40.000. , External Circlip (55 Dia Shaft) Cart Part No 50.501.55.000. , Circlip Internal : 32 Mm Cart Part No 50.502.32.000. , Circlip (Internal)-35 Mm Cart Part No 50.502.35.000. , Circlip Internal - 40 Mm Cart Part No 50.502.40.000. , Circlip: Internal 42Mm Cart Part No 50.502.42.000. , Circlip Internal : 45 Mm Cart Part No 50.502.45.000. , Circlip Internal - 47 Mm Cart Part No 50.502.47.000. , Circlip Internal - 52 Mm Cart Part No 50.502.52.000. , Circlip Internal-55Mm Cart Part No 50.502.55.000. , Circlip Internal - 62 Mm Cart Part No 50.502.62.000. , Circlip Internal 68 Mm Cart Part No 50.502.68.000. , Circlip Internal - 72 Mm Cart Part No 50.502.72.000. , Circlip Internal - 80 Mm Cart Part No 50.502.80.000. , Circlip Internal - 90 Mm Cart Part No 50.502.90.000. , Banjo Cart Part No 50.503.04.000. , Banjo Bolt: M8x1.25 Cart Part No 50.504.01.000. , Banjo Bolt: M10x1.5 Cart Part No 50.504.02.000. , Banjo Bolt: M12x1.5 Cart Part No 50.504.03.000. , Banjo Bolt :M14x1.5 Cart Part No 50.504.04.000. , Banjo Bolt - M16x1.5 Cart Part No 50.504.05.000. , Banjo Bolt: M18x1.5 Cart Part No 50.504.06.000. , Banjo Bolt M22x1 5 Cart Part No 50.504.07.000. , Banjo Bolt M30x1 5 Cart Part No 50.504.09.000. , Spring Washer - M5 Cart Part No 50.505.05.000. , Spring Washer -M6 Cart Part No 50.505.06.000. , Spring Washer - M8 Cart Part No 50.505.08.000. , Spring Washer - M10 Cart Part No 50.505.10.000. , Spring Washer - M12 Cart Part No 50.505.12.000. , Spring Washer - M14 Cart Part No 50.505.14.000. , Spring Washer - M16 Cart Part No 50.505.16.000. , Spring Washer - M18 Cart Part No 50.505.18.000. , Spring Washer - M20 Cart Part No 50.505.20.000. , Spring Washer - M24 Cart Part No 50.505.24.000. , Plain Machined Washer - M4 Cart Part No 50.506.04.000. , Plain Machined Washer - M5 Cart Part No 50.506.05.000. , Plain Machined Washer - M6 Cart Part No 50.506.06.000. , Plain Machine Washer - M8 Cart Part No 50.506.08.000. , Plain Machined Washer - M10 Cart Part No 50.506.10.000. , Plain Machine Washer - M12 Cart Part No 50.506.12.000. , Plain Machined Washer - M14 Cart Part No 50.506.14.000. , Plain Machined Washer - M16 Cart Part No 50.506.16.000. , Plain Machined Washer M18 Cart Part No 50.506.18.000. , Plain Machined Washer - M20 Cart Part No 50.506.20.000. , Plain Machined Washer - M22 Cart Part No 50.506.22.000. , Plain Machined Washer - M24 Cart Part No 50.506.24.000. , Plain Punched Washer - M6 Cart Part No 50.507.06.000. , Plain Punched Washer - M8 Cart Part No 50.507.08.000. , Plain Punched Washer - M10 Cart Part No 50.507.10.000. , Plain Punched Washer M12 Cart Part No 50.507.12.000. , Copper Washer (6X9) Cart Part No 50.508.03.000. , Copper Washer (6X10) Cart Part No 50.508.04.000. , Copper Washer (8X12) Cart Part No 50.508.05.000. , Copper Washer (8X14) Cart Part No 50.508.06.000. , Copper Washer (10X14) Cart Part No 50.508.07.000. , Copper Washer (10X16) Cart Part No 50.508.08.000. , Copper Washer (12X16) Cart Part No 50.508.09.000. , Copper Washer (12X18) Cart Part No 50.508.10.000. , Copper Washer (14X18) Cart Part No 50.508.11.000. , Copper Washer (14X20) Cart Part No 50.508.12.000. , Copper Washer (16X20) Cart Part No 50.508.13.000. , Copper Washer (16X22) Cart Part No 50.508.14.000. , Copper Washer (17X23) Cart Part No 50.508.15.000. , Copper Washer (18X22) Cart Part No 50.508.16.000. , Copper Washer (18X24) Cart Part No 50.508.17.000. , Copper Washer (20X24) Cart Part No 50.508.18.000. , Copper Washer (20X26) Cart Part No 50.508.19.000. , Copper Washer (20X27) Cart Part No 50.508.20.000. , Copper Washer (21X27) Cart Part No 50.508.21.000. , Copper Washer (21X31) Cart Part No 50.508.22.000. , Copper Washer (22X27) Cart Part No 50.508.23.000. , Copper Washer (22X29) Cart Part No 50.508.24.000. , Copper Washer( 22.2X28.5) Cart Part No 50.508.25.000. , Copper Washer (24X29) Cart Part No 50.508.27.000. , Copper Washer (26X32) Cart Part No 50.508.29.000. , Copper Washer (27X34) Cart Part No 50.508.31.000. , Copper Washer (28X33) Cart Part No 50.508.32.000. , Copper Washer (30X34) Cart Part No 50.508.33.000. , Copper Washer (30X36) Cart Part No 50.508.34.000. , Copper Washer (30X38) Cart Part No 50.508.35.000. , Copper Washer (48X52) Cart Part No 50.508.45.000. , Hose Clip Cart Part No 50.519.02.000. , Hose Clip 48Mm Cart Part No 50.519.09.000. , Banjo Bolt 1 4Bsp Cart Part No 50.538.03.000. , Spring Dowel Pin Cart Part No 50.540.09.016. , Spring Dowel (6 X 45) Cart Part No 50.540.10.045. , Spring Dowel Cart Part No 50.540.11.018. , Pipe Clipfor 2 Pipes Cart Part No 50.541.01.000. , Notched Pin Cart Part No 50.543.09.010. , Washer M5 Cart Part No 50.548.05.000. , Washer Cart Part No 50.548.06.000. , Spl Plain Machined Washer Cart Part No 50.548.08.000. , Special Plainwasher - M10 Cart Part No 50.548.10.000. , Spl Plain Washer - M12 Cart Part No 50.548.12.000. , Spl Plain Washer - M14 Cart Part No 50.548.14.000. , Washer Cart Part No 50.548.18.000. , Special Washer. Cart Part No 50.548.20.000. , Core Plug 1/4Bsp Cart Part No 50.601.02.000. , Drain Plug 3/8 Bsp Cart Part No 50.601.03.000. , Plug: M14x1.5 Cart Part No 50.602.14.000. , Core Plug Cart Part No 50.602.18.000. , Core Plug (Dish Type) Cart Part No 50.609.13.000. , Core Plug Cart Part No 50.610.10.000. , Core Plug Cart Part No 50.610.12.000. , Core Plug-Hexagonal Socket Head(Din-908) Cart Part No 50.610.14.000. , Core Plug Hexagonal Socket Head Din 908 Cart Part No 50.610.16.000. , Core Plug Hexagonal Socket Head(Din 908) Cart Part No 50.610.20.000. , Core Plug Hexagonal Socket Head(M22x1.5) Cart Part No 50.610.22.000. , Core Plug Cart Part No 50.610.24.000. , Core Plug(M27x2)-Hexagonal Socket Head(Din 908) Cart Part No 50.610.27.000. , Core Plug Hexagonal Socket Head Din 908 Cart Part No 50.610.30.000. , Core Plug Cart Part No 50.611.06.000. , Core Plug Hexagonal Headdin 7604 Cart Part No 50.611.07.000. , Worm Drive Hose Clip18 Mm Cart Part No 50.907.02.000. , Worm Drive Hose Clip (22 Mm) Cart Part No 50.907.03.000. , Worm Drive Hose Clip (25 Mm) Cart Part No 50.907.04.000. , Worm Drive Hose Clip (28 Mm) Cart Part No 50.907.05.000. , Hose Clip: Worm Drive 32Mm Cart Part No 50.907.06.000. , Worm Drive Hose Clip (41 Mm) Cart Part No 50.907.07.000. , Worm Drive Hose Clip (45 Mm) Cart Part No 50.907.08.000. , Worm Drive Hose Clip (55 Mm) Cart Part No 50.907.09.000. , Worm Drive Hose Clip (70 Mm) Cart Part No 50.907.10.000. , Worm Drive Hose Clip80 Mm Cart Part No 50.907.11.000. , Worm Drive Hose Clip90 Mm Cart Part No 50.907.12.000. , Worm Drive Hose Clip (102 Mm) Cart Part No 50.907.13.000. , Worm Drive Hose Clip (115 Mm) Cart Part No 50.907.14.000. , Worm Drive Hose Clip (127 Mm) Cart Part No 50.907.15.000. , Flanged Nut Grade 8 Cart Part No 50.908.05.000. , Flanged Nut Grade 8 Cart Part No 50.908.06.000. , Flangedm8 Nut Grade 8 Cart Part No 50.908.08.000. , Flanged Nut (Hexagon) Cart Part No 50.908.10.000. , Flanged Nut Grade 8 Cart Part No 50.908.12.000. , Falnged Bolt Grade 8.8 Cart Part No 50.911.05.014. , Flanged Bolt Grade 8.8M6 X 1 X 10 Cart Part No 50.911.06.010. , Flanged Bolt Grade 8.8M6 X 1 X 012 Cart Part No 50.911.06.012. , Flanged Bolt Grade 8.8M6 X 1.25 X 15 Cart Part No 50.911.06.015. , Flanged Bolt Grade 8.8M6 X 1.25 X 16 Cart Part No 50.911.06.016. , Flanged Bolt Grade 8.8M6 X 1 X 20 Cart Part No 50.911.06.020. , Flanged Bolt Grade 8.8M6 X 1 X 25 Cart Part No 50.911.06.025. , Flanged Bolt Grade 8.8M6 X 1 X 035 Cart Part No 50.911.06.035. , Flanged Bolt Grade 8.8M6 X 1 X 40 Cart Part No 50.911.06.040. , Flanged Bolt Grade 8.8M6 X 1 X 045 Cart Part No 50.911.06.045. , Flanged Bolt Grade 8.8M6 X 1 X 050 Cart Part No 50.911.06.050. , Flanged Bolt 8.8 Grade Cart Part No 50.911.06.055. , Flanged Bolt Grade 8.8M6 X 1 X 060 Cart Part No 50.911.06.060. , Flanged Bolt Grade 8.8M8 X 1.25 X 012 Cart Part No 50.911.08.012. , Flanged Bolt Grade 8.8M8 X 1.25 X 15 Cart Part No 50.911.08.015. , Flanged Bolt Grade 8.8M8 X 1.25 X 16 Cart Part No 50.911.08.016. , Flanged Bolt Grade 8.8M8 X 1.25 X 018 Cart Part No 50.911.08.018. , Flanged Bolt Grade 8.8M8 X 1.25 X 20 Cart Part No 50.911.08.020. , Flanged Bolt Grade 8.8M8 X 1.25 X 022 Cart Part No 50.911.08.022. , Flanged Bolt Grade 8.8M8 X 1.25 X 25 Cart Part No 50.911.08.025. , Flanged Bolt Grade 8.8M8 X 1.25 X 28 Cart Part No 50.911.08.028. , Flanged Bolt Grade 8.8 Cart Part No 50.911.08.030. , Flanged Bolt Grade 8.8M8 X 1.25 X 35 Cart Part No 50.911.08.035. , Flanged Bolt Grade 8.8M8 X 1.25 X 40 Cart Part No 50.911.08.040. , Flanged Bolt Grade 8.8M8 X 1.25 X 45 Cart Part No 50.911.08.045. , Flanged Bolt Grade 8.8M8 X 1.25 X 050 Cart Part No 50.911.08.050. , Flanged Bolt Grade 8.8M8 X 1.25 X 055 Cart Part No 50.911.08.055. , Flanged Bolt Grade 8 8 Cart Part No 50.911.08.060. , Flanged Bolt Grade 8.8M8 X 1.25 X 65 Cart Part No 50.911.08.065. , Flanged Bolt Grade 8.8M8 X 1.25 X 070 Cart Part No 50.911.08.070. , Flanged Bolt Grade 8.8M8 X 1.25 X 80 Cart Part No 50.911.08.080. , Flanged Bolt Grade 8.8M8 X 1.25 X 085 Cart Part No 50.911.08.085. , Flanged Bolt Grade 8.8M8 X 1.25 X 090 Cart Part No 50.911.08.090. , Flanged Bolt Grade 8.8M8 X 1.25 X 110 Cart Part No 50.911.08.110. , Flanged Bolt Grade 8.8M8 X 1.25 X 115 Cart Part No 50.911.08.115. , Flanged Bolt Grade 8.8M8 X 1.25 X 120 Cart Part No 50.911.08.120. , Flanged Bolt Grade 8.8M8 X 1.25 X 130 Cart Part No 50.911.08.130. , Flanged Bolt Grade 8 8M8 X 1 25 X 140 Cart Part No 50.911.08.140. , Flanged Bolt Grade 8.8 Cart Part No 50.911.10.015. , Flanged Bolt Grade 8.8M10 X 1.5 X 20 Cart Part No 50.911.10.020. , Flanged Bolt Grade 8.8M10 X 1.5 X 022 Cart Part No 50.911.10.022. , Flanged Bolt Grade 8.8M10 X 1.5 X 25 Cart Part No 50.911.10.025. , Flanged Bolt Grade 8.8M10 X 1.5 X 30 Cart Part No 50.911.10.030. , Flanged Bolt Grade 8.8M10 X 1.5 X 35 Cart Part No 50.911.10.035. , Flanged Bolt Grade 8.8M10 X 1.5 X 40 Cart Part No 50.911.10.040. , Flanged Bolt Grade 8 8M10 X 1 5 X 50 Cart Part No 50.911.10.050. , Flanged Bolt Grade 8.8M10 X 1.5 X 55 Cart Part No 50.911.10.055. , Flanged Bolt Grade 8.8M10 X 1.5 X 65 Cart Part No 50.911.10.065. , Flanged Bolt Grade 8.8M10 X 1.5 X 70 Cart Part No 50.911.10.070. , Flanged Bolt Grade 8.8 Cart Part No 50.911.10.075. , Flanged Bolt Grade 8.8M10 X 1.5 X 80 Cart Part No 50.911.10.080. , Flanged Bolt Grade 8 8M10 X 1 5 X 85 Cart Part No 50.911.10.085. , Flanged Bolt Grade 8 8M10 X 1 5 X 90 Cart Part No 50.911.10.090. , Flanged Bolt Grade 8 8 M10 X 1 5 X 105 Cart Part No 50.911.10.105. , Flanged Bolt Grade 8.8M12 X 1.75 X 25 Cart Part No 50.911.12.025. , Flanged Bolt Grade 8.8M12 X 1.75 X 30 Cart Part No 50.911.12.030. , Flanged Bolt Grade 8.8M12 X 1.75 X 35 Cart Part No 50.911.12.035. , Flanged Bolt Grade 8.8M12 X 1.75 X 90 Cart Part No 50.911.12.090. , Flanged Bolt Grade 8.8M12 X 1.75 X 190 Cart Part No 50.911.12.190. , Flanged Bolt (Grade 10.9) M8 X 1.25 X 020 Cart Part No 50.912.08.020. , Hexagonal Flanged Bolts(Grade 10.9) Cart Part No 50.912.08.025. , Flanged Bolt Grade 8.8, M8x1.5X030 Cart Part No 50.912.08.030. , Flanged Bolt Cart Part No 50.912.08.035. , Hexagonal Bolts With Flange (Grade 10.9) Cart Part No 50.912.10.025. , Flanged Bolt 10.9 Grade Cart Part No 50.912.12.050. , Flanged Nut Grade 10.9 Cart Part No 50.915.06.000. , Flanged Nut 10.9 Grade Cart Part No 50.915.08.000. , Cambush Cart Part No 5H.001.08.0.Pr , Crankcase Assly With Mb Cap Cart Part No 5H.001.110.0.Pr , Crankcase Assly With Mb Cap Cart Part No 5H.001.70.0.Pr , Crankcase Assly With Mb Cap Cart Part No 5H.001.90.0.Pr , Crankshaft (Machining) With Integral Balance Weight Cart Part No 5H.005.03.0.00 , Crankshaft Asslywith Gear Cart Part No 5H.005.90.0.Pr , Cyl Head Assemblycomplete Cart Part No 5H.007.30.0.Pr , Cyl Head With Valve Guide Valve Seat Insert Cart Part No 5H.007.50.0.Pr , O Ring: Cylinder Liner Cart Part No 5H.008.02.0.00 , Cyl Liner Assembly Cart Part No 5H.008.10.0.00 , Piston Assembly Cart Part No 5H.009.10.0.00 , Piston Assly. Complete Cart Part No 5H.009.130.0.Pr , Piston Asslycomplete Cart Part No 5H.009.50.0.Pr , Piston Ring Set3 Ring Version Cart Part No 5H.009.60.0.Pr , Piston Asslycomplete Cart Part No 5H.009.90.0.Pr , Injector Clamp Cart Part No 5H.010.02.0.Pr , Dowel Pin (For Injector Clamp) Cart Part No 5H.010.03.0.Pr , Inlet Manifold Cart Part No 5H.013.01.0.00 , Inlet Manifold Cart Part No 5H.013.01.0.Pr , Inlet Manifold Cart Part No 5H.013.02.0.Pr , Exhaust Manifold4 Valve Cart Part No 5H.014.01.0.Pr , Exhaust Manifold Cart Part No 5H.014.02.0.00 , Exhaust Manifold Cart Part No 5H.014.03.0.Pr , Gasket (For Turbocharger) Cart Part No 5H.014.04.0.Pr , Expansion Bellow Cart Part No 5H.014.08.0.Pr , Exhaust Manifold With Hr Paint Cart Part No 5H.014.11.0.00 , Gear Casing Cart Part No 5H.015.02.0.00 , Joint Cart Part No 5H.015.14.0.Pr , Support For Idler Pulley Cart Part No 5H.015.23.0.Pr , Idler Pulley Cart Part No 5H.015.31.0.Pr , Cb18 Fuel Pump Cart Part No 5H.016.01.0.Pr , Oil Supply Pipefor Fuel Pump Cart Part No 5H.016.02.0.Pr , Hub(For Fuel Pump Gear) Cart Part No 5H.018.01.0.Pr , Spin On Cartridge For 5H019 02 0 Pr Bs Iv Pre Filter Cart Part No 5H.019.001.0.00 , Spin On Cartridge For 5H019 01 0 Pr Bs Iv Main Fuel Filter Cart Part No 5H.019.002.0.00 , Fuel Filter With Hand Primer Cart Part No 5H.019.01.0.00 , Pre Filter Cart Part No 5H.019.02.0.00 , Water In Fuel Switch (Common Rail) Cart Part No 5H.019.03.0.Pr , 50 Hrs - A Check Maintenance Kit Cart Part No 5H.019.13.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.019.14.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 5H.019.16.0.Sp , Adaptorrocker Cover Breather Hose Cart Part No 5H.020.02.0.Pr , Gasketbreather Adaptor Rocker Cover Cart Part No 5H.020.04.0.00 , Breather Pipe Cart Part No 5H.020.08.0.Pr , Breather Pipe Cart Part No 5H.020.13.0.Pr , Breather Pipe Cart Part No 5H.020.14.0.Pr , Hose Cart Part No 5H.020.15.0.Pr , Breather Pipe Cart Part No 5H.020.17.0.Pr , Hose (540L) Cart Part No 5H.020.18.0.Pr , Hose580l Cart Part No 5H.020.19.0.Pr , Hose660l Cart Part No 5H.020.21.0.00 , Cover For Cam Bore Cart Part No 5H.022.02.0.Pr , Cover Plate For Fuel Pump Cart Part No 5H.023.02.0.Pr , Camshaft Assembly Cart Part No 5H.024.20.0.Pr , Camshaft Assly Cart Part No 5H.024.50.0.Pr , Gasketbellow Exhaust Manifold Cart Part No 5H.025.02.0.00 , Expansion Bellowfor Exhaust Cart Part No 5H.025.04.0.Pr , O Ring (Egr Water In & Out) Cart Part No 5H.025.08.0.Pr , Gasketexhaust Pipe Egr Cooler Cart Part No 5H.025.11.0.Pr , Oringegr Cooler Water In Cart Part No 5H.025.13.0.Pr , Oringegr Cooler Water Out Cart Part No 5H.025.14.0.Pr , Expansion Bellow Cart Part No 5H.025.16.0.Pr , Egr Pipeegr Valve Side Cart Part No 5H.025.17.0.00 , Egr Pipeegr Valve Side Cart Part No 5H.025.17.0.Pr , Exhaust Pipebellow To Egr Cart Part No 5H.025.21.0.Pr , Egr Pipeegr Cooler Side Cart Part No 5H.025.22.0.00 , Adaptoregr Cooler Water In Cart Part No 5H.025.23.0.00 , Adaptoregr Cooler Water In Cart Part No 5H.025.23.0.Pr , Adaptoregr Cooler Water Out Cart Part No 5H.025.24.0.00 , Adaptoregr Cooler Water Out Cart Part No 5H.025.24.0.Pr , Egr Cooler 5 Kw Cart Part No 5H.025.25.0.00 , Gasketbetween Egr Cooler And Exhaust Pipe Cart Part No 5H.025.26.0.00 , Adaptor Cart Part No 5H.025.27.0.00 , Fuel Pipe (Fuel Pump To Fuel Filter) Cart Part No 5H.026.02.0.00 , Plate (For Fuel Pipe Clamp) Cart Part No 5H.026.04.0.Pr , Bracketfor Fuel Filter Cart Part No 5H.026.06.0.Pr , Egr Valve Assembly For 4R1190 Bs-Iv Cart Part No 5H.027.01.0.Pr , Adaptor Cart Part No 5H.027.03.0.Pr , Gasketegr Mixer Inlet Manifold Cart Part No 5H.027.05.0.Pr , Hoseegr Valve Water Inlet Cart Part No 5H.027.06.0.Pr , Hoseegr Valve Water Out Cart Part No 5H.027.07.0.Pr , Gasket Between Egr Valve And Egr Pipe Cart Part No 5H.027.08.0.00 , Gasket Between Egr Mixer And Egr Valve Cart Part No 5H.027.09.0.00 , Platefor Hose Clamp Cart Part No 5H.027.11.0.Pr , Clamp Cart Part No 5H.027.12.0.Pr , Clamp Cart Part No 5H.027.14.0.Pr , Spring Band Clamp Id 13.3-14 Cart Part No 5H.027.15.0.Pr , Adaptor Cart Part No 5H.027.16.0.Pr , Hose Cart Part No 5H.027.21.0.Pr , Hose (Crankcase To Egr Valve) Cart Part No 5H.027.22.0.Pr , Gasketthrottle Valve Mixer Cart Part No 5H.029.02.0.Pr , Gasketthrottle Valve Heater Cart Part No 5H.029.03.0.Pr , Spacerfor Intake Throttle Valve Cart Part No 5H.029.05.0.Pr , Intake Throttle Valve (Yazaki Connector) Cart Part No 5H.029.07.0.Pr , Vband Clamp Cart Part No 5H.030.01.0.Pr , Bracket For Ecu Mounting Cart Part No 5H.031.02.0.Pr , Gasketrocker Cover Cart Part No 5H.032.02.0.00 , Wire Mesh66 5X10x18 236 Gaugesteel Wire Cart Part No 5H.032.03.0.Pr , Baffle Plate Cart Part No 5H.032.04.0.Pr , Bolt For Rocker Cover Cart Part No 5H.032.05.0.Pr , Rocker Cover Cart Part No 5H.032.06.0.Pr , Baffle Plate Cart Part No 5H.032.09.0.Pr , Rocker Cover Assembly Cart Part No 5H.032.70.0.Pr , Valve Bridge (For Rocker Lever) Cart Part No 5H.034.09.0.Pr , Valve Rocker Leverassy Complete Cart Part No 5H.034.50.0.Pr , Shaft Sub Assembly (4 Valve) Cart Part No 5H.034.60.0.00 , Intake Rocker Arm – Hla Assembly Cart Part No 5H.034.70.0.Pr , Exhaust Rocker Arm – Hla Assembly Cart Part No 5H.034.80.0.Pr , Valve Rocker Lever (Assy Complete) Cart Part No 5H.034.90.0.Pr , Leakoff Pipe Cart Part No 5H.035.01.0.Pr , Platefor Leak Off Clamp Cart Part No 5H.035.08.0.Pr , Clamp Cart Part No 5H.035.11.0.Pr , Clamp (For Tube Od 6-6.5) Cart Part No 5H.035.17.0.Pr , Metallic Leak Off Pipe (Injector Side) Cart Part No 5H.035.18.0.Pr , Worm Drive Hose Clamp (Dia 6) Cart Part No 5H.035.19.0.Pr , Bracketdoc Mounting Cart Part No 5H.036.02.0.Pr , Bracket For Doc Mounting Cart Part No 5H.036.08.0.Pr , Bracket For Scr Mounting Cart Part No 5H.036.09.0.Pr , Urea Tank Assembly 4R1190ta Bsiv Cart Part No 5H.036.10.0.Pr , Adblue Tank Bracket Assly Cart Part No 5H.036.100.0.Pr , Urea Return Pipe Supply Module To Tank Cart Part No 5H.036.101.0.Pr , Urea Pipe (Tank To Supply Module) Cart Part No 5H.036.102.0.Pr , Clamp Two Pipe Clip Id 8 9 Cart Part No 5H.036.103.0.Pr , Coated Ceramic Substrate (5.2D X 5.25L) With 5G/Ft3 Pt Loading Cart Part No 5H.036.125.0.Pr , Water In Pipe Pipe (Crancase To Dosing Module) Cart Part No 5H.036.137.0.Pr , Water In Pipe Cart Part No 5H.036.143.0.Pr , Water Out Pipe (Dosing Module To Thermostat For Top Mounted)) Cart Part No 5H.036.148.0.Pr , Mounting Bracket For Doc Scr Cart Part No 5H.036.17.0.Pr , 4R1190ta Bsiv Urea Tank Assemblywith Modified Filter And Rua Table Urea Tank A Cart Part No 5H.036.18.0.Pr , Bracket For Scu Mounting Cart Part No 5H.036.19.0.Pr , Docupward Opening (Diesel Oxidation Catalyst) Cart Part No 5H.036.20.0.Pr , Doc Mounting Bracket Cart Part No 5H.036.24.0.Pr , Doc Mountingbracket Support 2 Cart Part No 5H.036.25.0.Pr , Doc Mountingbracket Support 1 Cart Part No 5H.036.26.0.Pr , Docdownward Opening 20 Cart Part No 5H.036.30.0.Pr , Urea Tank Air Vent Cart Part No 5H.036.31.0.Pr , Urea Tank O-Ring Cart Part No 5H.036.32.0.Pr , Urea Tank Filling Neck Cart Part No 5H.036.33.0.Pr , Urea Tank Locking Cap Cart Part No 5H.036.34.0.Pr , Urea Tank Adblue Sensor Cart Part No 5H.036.35.0.Pr , Urea Tank Filler Filter Cart Part No 5H.036.36.0.Pr , Urea Tank Drain Plug Cart Part No 5H.036.37.0.Pr , Jsr01144,O Ring For Sensor Cart Part No 5H.036.41.0.Pr , Adblue Level ,Quality Temp Sensor For 25 Ltr Tank Cart Part No 5H.036.43.0.Pr , 5H 036 70 0 00Doc 4 75 Ltr Na Type 4 Platform 1 Gm Cft 1 0 05 2X 5 2X 5 25L400 4 Cart Part No 5H.036.70.0.00 , Rubber Mount 25X20 Cart Part No 5H.036.88.0.Pr , Plate Cart Part No 5H.036.89.0.Pr , Rubber Strip Cart Part No 5H.036.96.0.Pr , Doc (Upward Opening) Cart Part No 5H.037.20.0.Sp , O Ring Air Sensor Adaptor Cart Part No 5H.039.02.0.Pr , Spacer Plate Cart Part No 5H.039.03.0.Pr , Pipe (Air Inlet) Cart Part No 5H.039.04.0.Pr , Adaptorfor Air Sensor Cart Part No 5H.039.05.0.Pr , V Band Clamp Cart Part No 5H.039.06.0.Pr , H Ppipefor Cyl1 Cart Part No 5H.040.10.0.00 , Hppipefor Cyl2 Cart Part No 5H.040.20.0.00 , Hppipefor Cyl3 Cart Part No 5H.040.30.0.00 , Hppipefor Cyl4 Cart Part No 5H.040.40.0.00 , Hppipepump To Rail Cart Part No 5H.040.50.0.00 , Hppipepump To Rail Cart Part No 5H.040.60.0.00 , Engine Wiring Harness For 4R1190na Bsiv Engine Cart Part No 5H.043.22.0.Pr , Engine Wiring Harness For 4R1190ta Bsiv Engine Cart Part No 5H.043.32.0.Pr , Header For Lub Oil Cooler And Spin On Filter Cart Part No 5H.045.01.0.00 , Headerfor Remote Lub Oil Filter Cart Part No 5H.045.02.0.Pr , Extension Wiring Harness For 4R1190ta Bs-Iv Engine 110Hp (For Top Mtg Egt) Cart Part No 5H.045.32.0.Pr , Extension Wiring Harness For 4R1190ta Bs Iv Engine 110Hpfor Flywheel Mtg Egt Cart Part No 5H.045.50.0.Pr , Lub Oil Cooler Header Assembly Cart Part No 5H.045.90.0.Pr , Heater Wire Support Bracket S F 4R1190 Bsiv Engine Cart Part No 5H.046.122.0.Pr , Air Cleaner Assembly (350 Kg/Hr) 90 Deg Bend Outlet Spout (Fp-G080726) Cart Part No 5H.050.10.0.Pr , Platefor Roller Tappet Cart Part No 5H.051.05.0.Pr , Platefor Roller Tappet Cart Part No 5H.051.07.0.Pr , Roller Tappet Assembly Cart Part No 5H.051.10.0.Pr , Push Rod (Welded) Cart Part No 5H.051.30.0.Pr , Adaptor (For Turbo Oil Inlet 11/16-16 Unf To 12) Cart Part No 5H.053.01.0.Pr , Adaptor Crankcase Sideunf 11 16 16 Cart Part No 5H.053.02.0.Pr , Lub Oil Supply Pipefor Turbocharger Cart Part No 5H.053.10.0.Pr , Drain Pipewith Flange And Sleeve Cart Part No 5H.053.20.0.Pr , Turbo Drain Pipe Cart Part No 5H.053.22.0.Pr , Lub Oil Supply Pipefor Turbocharger Cart Part No 5H.053.30.0.Pr , Drain Pipewith Flange And Sleeve Cart Part No 5H.053.40.0.Pr , Turbo Oil In Pipe Cart Part No 5H.053.50.0.Pr , Turbo Oil Drain Pipe Cart Part No 5H.053.60.0.Pr , Turbo Drain Pipe Cart Part No 5H.053.70.0.Pr , Drain Pipewith Flange Sleeve Cart Part No 5H.053.71.0.Pr , Turbo Drain Pipewith Flange Sleeve Cart Part No 5H.053.80.0.Pr , Crankshaft Pulley With Poly V Groove For 143 Pcd Cart Part No 5H.054.01.0.Pr , Pulley100 Pcdpolyv For Water Pump Cart Part No 5H.055.01.0.Pr , 115529021814 Turbocharger Cart Part No 5H.056.01.0.Pr , Turbocharger Cart Part No 5H.056.02.0.Pr , Turbocharger Cart Part No 5H.056.05.0.Pr , Turbocharger For 4R Cpcb4engine B1 055C81qs24a01enc110 24 058X71af18r70es Cart Part No 5H.056.07.0.Pr , Turbocharger For 4K1080ta Cpcb 4+ Engine Cart Part No 5H.056.10.0.Pr , Turbocharger For 4R1190t-Ht Top Mounted Orientation Cart Part No 5H.056.12.0.Pr , Turbocharger Top Mounted Cart Part No 5H.056.18.0.Pr , Flywheel Housing Sae3w155ss Bb Cart Part No 5H.057.01.0.Pr , Flywheel Assembly Cart Part No 5H.058.20.0.Pr , Thermostat Housing Assembly Opening Toward Exhaust And Tall Height Cart Part No 5H.059.10.0.Pr , Exhaust Diffuser Cart Part No 5H.060.01.0.Pr , Expansion Bellow Cart Part No 5H.060.03.0.Pr , Exhaust Pipe Cart Part No 5H.060.04.0.Pr , Gasket (Exahust Pipe And Doc ) Cart Part No 5H.060.05.0.00 , Exhaust Pipe Cart Part No 5H.060.07.0.Pr , Exhaust Pipebetween Diffuser And Expansion Bellow Cart Part No 5H.060.08.0.Pr , Exhaust Pipe With Bellow (Doc Side ) Cart Part No 5H.060.17.0.Pr , V Clamp For Dm 3.2 Cart Part No 5H.061.02.0.Pr , Lub Oil Sumpdrain Plug At Bottom Side Cart Part No 5H.062.01.0.Pr , Closed Crankcase Ventilationccv 4R1190ta Cart Part No 5H.063.01.0.Pr , Bracket For Ccv Mtg 4R1190ta Cart Part No 5H.063.02.0.Pr , Hoseblow By In Cart Part No 5H.063.03.0.Pr , Oil Drain Hose4r1190ta Cart Part No 5H.063.04.0.Pr , Blow By Out Hose (Ccv Side) Cart Part No 5H.063.05.0.Pr , Intermediate Pipeccv Out Cart Part No 5H.063.06.0.Pr , Clamp Dia9 11 Cart Part No 5H.063.08.0.Pr , Clamp Cart Part No 5H.063.12.0.Pr , Hose Pipe Oil Drain To Sump Cart Part No 5H.063.18.0.Pr , Mtg. Bracket For Ccv (4R1190na) Cart Part No 5H.063.19.0.Pr , Oil Drain Hose Pipeccv To Sump Cart Part No 5H.063.21.0.Pr , Oil Drain Hose Pipeccv To Ci Sump Cart Part No 5H.063.25.0.Pr , Bracketfor Ccv Mounting Cart Part No 5H.063.31.0.Pr , Hose Piperocker Cover To Ccv Cart Part No 5H.063.32.0.Pr , Hose Pipeccv To Air Inlet Pipe Cart Part No 5H.063.33.0.Pr , Oil Drain Hoseccv To Ci Sump Cart Part No 5H.063.34.0.Pr , Pipe (Oil Drain To Sump) Cart Part No 5H.063.52.0.Pr , Hose12 Id 60 L Cart Part No 5H.063.66.0.Pr , Lube Oil Sump Fabricated Cart Part No 5H.064.01.0.Pr , Lub Oil Sumpfabricated Cart Part No 5H.064.03.0.Pr , Gasket Cart Part No 5H.070.01.0.Pr , V-Band Clamp Cart Part No 5H.070.02.0.Pr , Assembly Of Emission After Treatment For 110 Hp Bs Ivdoc Dcom Tube Scrvari Cart Part No 5H.070.10.0.Pr , Docside Mounted Cart Part No 5H.070.100.0.Pr , Scrside Mounted Cart Part No 5H.070.110.0.Pr , 4R1190ta Bsiv Egt Strap Assembly Spare Part Cart Part No 5H.070.120.0.Sp , Strap For Egt Assembly Cart Part No 5H.070.121.0.Pr , 4R1190na Bsiv Egt Strap Assembly Spare Part Cart Part No 5H.070.130.0.Sp , Assembly Of Emission After Treatment For 110 Hp Bs Ivdoc Dcom Tube Scrvari Cart Part No 5H.070.20.0.Pr , Doctop Mounted Cart Part No 5H.070.200.0.Pr , Scrtop Mounteddownward Opening Cart Part No 5H.070.210.0.Pr , Poly V Belt 6Pk 1215 Epdm Cart Part No 5H.071.01.0.Pr , Poly V Belt 6Pk 1270 Epdm Cart Part No 5H.071.02.0.Pr , Poly V Belt(6Pk-1295-Epdm) Cart Part No 5H.071.06.0.Pr , Pfm Sensor Air Mass Flow Sensor B Samplevariant Cart Part No 5H.085.04.0.Pr , Dosing Module For 4R1190 Bs4 Cart Part No 5H.085.06.0.00 , Adblue Inlet Line Filter Cart Part No 5H.085.07.0.Pr , Nox Sensor Cart Part No 5H.085.08.0.Pr , Supply Module For 4R1190 Bs4 Cart Part No 5H.085.09.0.Pr , Service Kit; (Dm 3.2) Re-Assembly Kit (Clamp And Seal) Cart Part No 5H.085.10.0.Sp , Nox Sensor Suitable For 24V System Cart Part No 5H.085.11.0.Pr , Urea Filter Cart Part No 5H.085.16.0.Sp , Suction Connection Piece Cart Part No 5H.085.21.0.Sp , Delta P Sensor Cart Part No 5H.085.30.0.Pr , Filter Service Set For 4R1190ta Sm Cart Part No 5H.085.51.0.Sp , Inlet Connector Set For 4R1190ta Sm Cart Part No 5H.085.53.0.Sp , Outlet Connector Set For 4R1190ta Sm Cart Part No 5H.085.54.0.Sp , Backflow Connector Set 4R1190ta Sm Cart Part No 5H.085.55.0.Sp , Rubber Sleeve Between Air Cleaner And Pre Cleaner Cart Part No 5H.086.01.0.Pr , Air Pre-Cleaner Suitable For 4R1190na Engine Cart Part No 5H.086.10.0.Pr , Gas Train Assembly For 4R1190ta Ng1 Png Cart Part No 5H.086.101.0.Pr , Lifting Hook G Esuitable For Bracket Mounting Cart Part No 5H.087.01.0.Pr , Lifting Hook F W Elow Height Cart Part No 5H.087.02.0.Pr , Bracket Air Cleaner Zigzag Welding Cart Part No 5H.089.01.0.Pr , Hose Air Suction Id70xid90 Zigzag Epdm Cart Part No 5H.089.02.0.Pr , Bracket Air Cleaner Zigzag Single Z Shape Cart Part No 5H.089.03.0.Pr , Heat Shield Between Air Cleanerhose And Doc Cart Part No 5H.089.04.0.Pr , Flywheel Assembly Cart Part No 5H.090.20.0.Pr , Thermostat Housing Assembly Opening Upward Cart Part No 5H.091.10.0.Pr , Flywheel Housing Sae Cart Part No 5H.092.01.0.Pr , Flywheel Assembly Cart Part No 5H.093.20.0.Pr , Hose Air Suction Id70xid89 Bend Epdm Cart Part No 5H.095.02.0.Pr , Hose Air Suction Id89xid89 Bend Epdm Cart Part No 5H.095.03.0.Pr , Bracket Air-Pipe Zigzag Welding Cart Part No 5H.095.05.0.Pr , Bracket Alternator Zigzag Single Casting Cart Part No 5H.096.01.0.Pr , Bracket Lub Oil Filter Zigzag Single Cart Part No 5H.097.01.0.Pr , Flywheel Assembly Cart Part No 5H.099.20.0.Pr , Thermostat Assembly Low Mounted Intake Manifold Side Open Cart Part No 5H.102.10.0.Pr , Thermostat Housing Assembly Opening Toward Exhaust And Small Height Cart Part No 5H.105.10.0.Pr , Spacer For Fan Stud Mounting Id9 Od14 L70 Cart Part No 5H.106.01.0.Pr , Hose Air Suction Id70xid89 Zigzag Epdm Cart Part No 5H.107.02.0.00 , Fuel Pipe Pa12 M14 Banjo Fuel Pump To Fuel Filter Cart Part No 5H.108.02.0.Pr , Element Assembly Safety Cart Part No 5H.109.02.0.00 , Element Assembly Primary Cart Part No 5H.109.03.0.00 , Air Cleaner Assembly350 Kg Hr90 Deg Bend Outlet Spout Cart Part No 5H.109.10.0.Pr , Flywheel Assembly Cart Part No 5H.111.10.0.Pr , Pipe Turbo Compressor Out To Cac Cart Part No 5H.112.01.0.Pr , O Ring Id 48X Dia3 Cart Part No 5H.112.02.0.Pr , V Band Clamp Nomdia65 Cart Part No 5H.112.03.0.Pr , Bracket For Turbo Compressor Out Pipe Bend Single Cart Part No 5H.112.04.0.Pr , Ccv Pipe Od63 5At Turbocharger Suction Straight Metallic Cart Part No 5H.112.06.0.Pr , Hose Turbo Air Suction Id6063 5Straight Epdm Cart Part No 5H.112.07.0.Pr , U Clamp For Cac Pipe Support Pipe O D75 Cart Part No 5H.112.08.0.Pr , Clamping Plate For U Clamp Zigzag Single Cart Part No 5H.112.09.0.Pr , Plug Cap 1 827 Nptf For Air Cleaner Restriction Indicator Cart Part No 5H.112.10.0.Pr , Bracket Alternator Zigzag Single Casting Cart Part No 5H.113.01.0.Pr , Hose Air Suction Id127xid63.5 Bend Epdm Cart Part No 5H.114.02.0.Pr , Pipe Cac In Air Presure Id 65 Od 75 Zigzag Casting Al Cart Part No 5H.115.01.0.Pr , Pipe Cac Out Air Presure Od 70 Zigzag Casting Al Cart Part No 5H.115.02.0.Pr , Pipe Cac In Air Presure Id 65 Od 75 Zigzag Casting Al Cart Part No 5H.115.03.0.Pr , Pipe Exhaust Gas Presure Od 88.9 Zigzag Welding Cart Part No 5H.117.01.0.Pr , Bracket Exhaust Pipe Zigzag Single Cart Part No 5H.117.02.0.Pr , Gasket Exhaust Gas Crs 85X4 Diameter 9 Id 89 Ss Cart Part No 5H.117.03.0.Pr , Pipe Oil Filling Presure Od 50 8Thk2 Zigzag Welding Cart Part No 5H.118.01.0.Pr , Hose Oil Filling Presure Id 50 8 Id 60 Straight Epdm Cart Part No 5H.118.02.0.Pr , Spacer For Mounting Fan 10 Mm Width Cart Part No 5H.119.01.0.Pr , Air Cleaner Assembly350 Kg Hr90 Deg Bend Outlet Spout Cart Part No 5H.121.10.0.Pr , Bracket Air Cleaner Zigzag Welding Cart Part No 5H.122.01.0.Pr , Hose Air Suction Id70xid89 Zigzag Epdm Cart Part No 5H.122.02.0.Pr , Hose Air Suction Id70xid70 Zigzag Epdm Cart Part No 5H.122.03.0.Pr , Pipe Air Suction Od70 Metallic Straight Welding Cart Part No 5H.122.04.0.Pr , Pipe Air Suction Id15xod18 Zigzag Metallic Rubber Cart Part No 5H.123.01.0.Pr , Bracket Compressor Air Pipe Flat Single Cart Part No 5H.123.02.0.Pr , Air Cleaner Assembly350 Kg Hr90 Deg Bend Outlet Spoutg080747 Cart Part No 5H.124.10.0.Pr , Bracket For Ecu Wiring Harness Interface Connector Support Cart Part No 5H.125.201.0.Pr , Hose Air Suction Id70xid89 Zigzag Epdm Cart Part No 5H.127.02.0.Pr , Heat Shield Inbetween Alternator And Exhaust Manifold Cart Part No 5H.128.01.0.Pr , Pipe Air Suction Od 88.9 X 88.9 Straight Metallic Cart Part No 5H.132.01.0.Pr , Bracket Air-Pipe Flat Welding Cart Part No 5H.132.03.0.Pr , Air Cleaner Mounting Bracket Cart Part No 5H.133.01.0.Pr , Air Cleaner Assembly (350 Kghr) 90 Deg Bend Outlet I-0 O-41 (Fp-G080754) Cart Part No 5H.133.10.0.Pr , Remote Mounting For Air Suction Restriction Indicator Cart Part No 5H.139.10.0.Pr , Bracket For Scu Mounting Cart Part No 5H.140.06.0.Pr , Bracket For Ccv Cart Part No 5H.140.28.0.Pr , Bellow(Turbo Side) Cart Part No 5H.141.01.0.Pr , Exhaust Pipe (Exhaust Manifold To Bellow) Cart Part No 5H.141.02.0.Pr , Exhaust Pipe (Bellow To Doc) Cart Part No 5H.141.03.0.Pr , Exhaust Pipe (With Bellow Doc Side ) Cart Part No 5H.141.05.0.Pr , Exhaust Manifold Cart Part No 5H.141.06.0.Pr , Exhaust Pipe (Bellow To Doc) Cart Part No 5H.141.07.0.Pr , Exhaust Pipe (Turbo To Bellow) Cart Part No 5H.141.08.0.Pr , Exhaust Pipe (Turbo To Doc) Cart Part No 5H.141.11.0.Pr , Exhaust Pipe (Bellow To Doc) Cart Part No 5H.141.12.0.Pr , Bellow(Turbo Side) Cart Part No 5H.141.21.0.Pr , Joint (B/W Exhaust Pipe And Expansion Bellow) Cart Part No 5H.141.22.0.Pr , Hose For Remote Lub Oil Filter, Pressure, Id 16, M22 Both Side, Bend, Rubber And M Cart Part No 5H.1415.01.0.Pr , Hose For Remote Lub Oil Filterpressureid 16M22 Both Sidebendrubber And M Cart Part No 5H.1415.02.0.Pr , Hose For Remote Lub Oil Filterpressureid 16M22 One Side Bendrubber And Met Cart Part No 5H.1415.03.0.Pr , Hose For Remote Lub Oil Filterpressureid 16M22 Both Sidebendrubber And M Cart Part No 5H.1415.04.0.Pr , Water Out Pipe (Dosing Water Out To Thermostat) Cart Part No 5H.142.03.0.Pr , Hose (Dp Sensor Hps) Cart Part No 5H.143.01.0.Pr , Hose For Dp Sensor (Lps) Cart Part No 5H.143.02.0.Pr , Oil Drain Hose (Ccv To Sump) Cart Part No 5H.143.13.0.Pr , Turbo Out Hose Cart Part No 5H.143.18.0.Pr , Gasket For Exahust Pipe And Doc Cart Part No 5H.144.01.0.Pr , Gasket For Exahust Manifold And Pipe Cart Part No 5H.144.02.0.Pr , Heat Shield For Alternator Cart Part No 5H.144.03.0.Pr , Heat Shield On Expansion Bellow Cart Part No 5H.155.01.0.Pr , Air Cleaner Assembly 50 Deg Bend Outlet Spout Cart Part No 5H.155.20.0.Pr , Ccv_4R1190ta Bsv Cart Part No 5H.163.01.0.Pr , Closed Crankcase Ventilation_Ccv_4R1190na Bsv Cart Part No 5H.163.02.0.Pr , Coalescer Filter Element_Small Coalescer_Ccv_For Bsv & Tier Ivf Engines Cart Part No 5H.163.03.0.Pr , Coalescer Filter Element_Medium Coalescer_Ccv_For Bsv & Tier Ivf Engines Cart Part No 5H.163.04.0.Pr , 12V/3.3Kw Starter Motor With Gear Reduction (Model No. : Stm-27B04) Cart Part No 5H.302.01.0.Pr , 12V Starter Motor S F 4R1190 Bsiv Engine Cart Part No 5H.302.02.0.Pr , Cold Start Kit Bsiv 110Hp Ta Suitable For 5H 43545H 4359 Cart Part No 5H.435.40.0.Sp , Air Cleaner Hose To Turbo Cart Part No 5H.488.01.0.Pr , Adaptor M16 X 1.5 To M14 X 1.5 Cart Part No 5H.488.04.0.Pr , Coolent Pipe For (Dosing Module Out To Radiator In-1) Cart Part No 5H.488.28.0.Pr , Coolent Pipe For (Dosing Module Out To Radiator In-2) Cart Part No 5H.488.29.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) Cart Part No 5H.488.31.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-1) Cart Part No 5H.488.32.0.Pr , Adblue Pipe For (Add Blue Tank Out To Supply Module In) Cart Part No 5H.488.34.0.Pr , Adblue Pipe For (Supply Module Back Flow To Add Blue Tank In) Cart Part No 5H.488.36.0.Pr , Coolent Pipe Forcrankcase Out To Dosing Model In 1 Cart Part No 5H.488.37.0.Pr , Coolent Pipe For (Crankcase Out To Dosing Model In-2) Cart Part No 5H.488.38.0.Pr , Coolent Pipe For (Crankcase Out To Dosing Model In-3) Cart Part No 5H.488.39.0.Pr , Coolent Pipe For (Crankcase Out To Dosing Model In-4) Cart Part No 5H.488.41.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No 5H.488.43.0.Pr , Fuel Pipe (Pre Filter To Tank Unit) Cart Part No 5H.488.44.0.Pr , Return Fuel Pipe Cart Part No 5H.488.49.0.Pr , Vci Dongle Only, For Tester Tool Uds Protocol Cart Part No 5H.501.50.0.00 , Industrial Pigtail Harness Cart Part No 5H.501.90.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No 5H.510.02.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.510.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.06.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.07.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.08.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.510.10.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.511.01.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.511.03.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No 5H.520.01.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.520.02.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.520.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.520.04.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.530.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.530.04.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.530.06.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.530.08.0.Sp , 500 Hrs - B Check Maintenance Kit Cart Part No 5H.535.01.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.535.03.0.Sp , 1000 Hrs - Ccheck Maintenance Kit Cart Part No 5H.536.01.0.Sp , High Temperature Sensor Darts200 Aw Id25 Mi54sensata Cart Part No 5H.800.13.0.Pr , Coated Dpf Cart Part No 5H.800.28.0.Pr , Exhaust Gas After Treatmentupward Opening Cart Part No 5H.801.10.0.Sp , Exhaust Gas After-Treatment (20° Downward Opening) Cart Part No 5H.801.20.0.Pr , Exhaust Gas After-Treatment (55° Upward Inlet Opening) Cart Part No 5H.801.30.0.Pr , Gasket Cart Part No 5H.802.04.0.Pr , 4R1190ta Bsv Dosing Mixer Subassembly Cart Part No 5H.802.13.0.Pr , 4R1190 Bsv Dosing Mixer Subassembly Bidding Joint To Mixer Inlet Side Cart Part No 5H.802.14.0.Pr , 4R1190 Bsv Dosing Mixer Subassembly Side Mounted Egt Cart Part No 5H.802.15.0.Pr , Doc Dpf Assembly Cart Part No 5H.802.20.0.Pr , Scr Assembly Cart Part No 5H.802.30.0.Pr , Doc Dpf Assembly Cart Part No 5H.802.50.0.Pr , Scr Assembly Cart Part No 5H.802.60.0.Pr , Connecting Rod End Bearing 4R1190 Cart Part No 5H.999.01.0.Sp , Bsiv Cold Start Kit Till 0 Degree Cart Part No 5H.999.02.0.Sp , Bs Iv Diagnostic Kit Cart Part No 5H.999.05.0.Sp , Bsiv 4R1190 Cold Start Kit For Top Mounted Egt Cart Part No 5H.999.06.0.Sp , Bsiv 1190 Cold Start Kit For Side Mounted Egt Cart Part No 5H.999.07.0.Sp , Bsiv 1190 Cold Start Kit For Side Mounted Nisarg Cart Part No 5H.999.08.0.Sp , Breather Box Cart Part No 5H.999.10.0.Sp , Dynapac Closed Crankcase Ventilation Kit Cart Part No 5H.999.13.0.Sp , Wet Pm Kit (W/O Oil) For 5H.3021 - 4R1190 Cart Part No 5H.999.14.0.Sp , Wet Pm Kit (W/O Oil) For 5H.2001 Cart Part No 5H.999.15.0.Sp , Bs Iv 74.5 Hp Na & Ht Engines Consumables Filter Kit For 50 Hrs, 500 Hrs, And 1500 Hr Cart Part No 5H.999.22.0.Sp , Bs Iv 74.5 Hp Na Engines Consumables Filter Kit For 1000 Hrs Cart Part No 5H.999.23.0.Sp , Bs Iv 74.5 Hpht Engines Consumables Filter Kit For 1000 Hrs Cart Part No 5H.999.24.0.Sp , Bs Iv 110 Hp Engines Consumables Filter Kit For 500 Hrs And 1500 Hrs Cart Part No 5H.999.25.0.Sp , Bs Iv 110 Hp Engines Consumables Filter Kit For 1000 Hrs Cart Part No 5H.999.26.0.Sp , Breather Assembly Kit Cart Part No 5H.999.27.0.Sp , Adblue Inlet Line Filter Cart Part No 5H.999.28.0.Sp , Wet Pm Kit (W/O Oil) For 5H.3008 - 4R1190 Cart Part No 5H.999.30.0.Sp , Wet Pm Kit (W/O Oil ) For 5H.8901 Cart Part No 5H.999.31.0.Sp , Bracket Bsv 4R1190 Wiring Harness Resting Bracket-3 Ht Cart Part No 5H.B074.127.0.Pr , Engine Wiring Harness For Bsv 4R1190 Na1 & Ta-H.T Engines For 74.5 Hp Na1 Cart Part No 5H.E074.110.0.Pr , Engine Wiring Harness For Bsv 4R1190 Ta-H.T 74.5 Hp Ta-Ht(Above Rocker Cover),74. Cart Part No 5H.E074.120.0.Pr , Engine Wiring Harness For Bsv 4R1190 Engines For 110 Hp Ta1 (Top Mounted), Cart Part No 5H.E110.110.0.Pr , Egt Wiring Harness For Bsv 4R1190 Na1 & Ta-H.T Engines For 74.5 Hp Na1 Cart Part No 5H.X074.110.0.Pr , Egt Wiring Harness For Bsv 4R1190 Na1 Ta H T Engines For 74 5 Hp Na1above Exha Cart Part No 5H.X074.111.0.Pr , Egt Wiring Harness For Bsv 4R1190 Engine Of 74.5 Hp Ta-H.T (Fwh Mounted) Cart Part No 5H.X074.120.0.Pr , Egt Wiring Harness For Bsv 4R1190 Ta1 Engines For 110 Hp (Top Mounted) Cart Part No 5H.X110.110.0.Pr , Egt Wiring Harness For Bsv 4R1190 Ta1 Engines For 110 Hptop Mounted Cart Part No 5H.X110.111.0.Pr , Egt Wiring Harness For Bsv 4R1190ta1 Engines For 110 Hp (Fwh Mounted) Cart Part No 5H.X110.120.0.Pr , Nut Cart Part No 60.007.03.0.00 , V Belt : A43 Cart Part No 60.053.01.0.00 , V Belt: A44 Cart Part No 60.060.01.0.00 , V Belt A-45 Cart Part No 60.139.01.0.00 , Governer Spring Cart Part No 61.143.08.0.00 , Strainer Cart Part No 65.073.01.0.00 , Monoblock Crank Case Without Bearings Cart Part No 6H.001.100.0.Pr , Piston Cooling Nozzle Assly Cart Part No 6H.001.17.0.00 , Adapter For Lub Oil Tempswitch Cart Part No 6H.001.21.0.00 , Crankshaft Assly With Bal Wt Cart Part No 6H.002.40.0.00 , Cam Shaft & Gear Assembly Cart Part No 6H.003.10.0.00 , Lube Oil Pump Assly Cart Part No 6H.004.10.0.00 , Suction Tube Cart Part No 6H.006.20.0.00 , Cyl Head Gasket 1.22 Mm Thk Cart Part No 6H.007.06.0.00 , Cylinder Head Assly Cart Part No 6H.007.10.0.00 , High Pressure Pipe Assembly Cart Part No 6H.009.70.0.00 , Exhaust Manifold (Finish) Cart Part No 6H.011.01.0.00 , Exhaust Manifold (Side Piece) Cart Part No 6H.011.04.0.00 , Exhaust Manifold (Central Piece) Cart Part No 6H.011.05.0.00 , Spacer Plate (For Turbo Charger) Cart Part No 6H.011.06.0.00 , Assembly Of Adaptor & Pipe Cart Part No 6H.012.03.0.00 , Rocker Shaft Assembly Cart Part No 6H.012.10.0.00 , Rocker Shaft Assembly Cart Part No 6H.012.140.0.00 , Rocker Shaft Assembly Cart Part No 6H.012.50.0.00 , Rocker Cover Gasket Cart Part No 6H.013.15.0.00 , Rocker Cover Cart Part No 6H.013.40.0.00 , Header(For Locooler & Spin On Filter) Cart Part No 6H.014.03.0.00 , Joint: Header Cart Part No 6H.014.11.0.00 , Header & Cooler Assly Cart Part No 6H.014.20.0.00 , Crankshaft Pulley Cart Part No 6H.018.02.0.00 , Extension Pulley (140 Pcd) Cart Part No 6H.018.03.0.00 , Crank Pulley For 6Rt/Ta Pg Engines Cart Part No 6H.018.06.0.Pr , Plate For Stay Cart Part No 6H.019.01.0.00 , Rubber Bush Cart Part No 6H.019.06.0.00 , Steel Bush Cart Part No 6H.019.07.0.00 , Special Washer Cart Part No 6H.019.08.0.00 , Stay For Radiator Cart Part No 6H.019.09.0.00 , Hose: Water Pipe Cart Part No 6H.019.12.0.00 , Stay For Radiator Cart Part No 6H.019.15.0.00 , Joint: Crankcase & Gear Casing Cart Part No 6H.020.04.0.00 , Joint: Crankcase & Gear Cover Cart Part No 6H.020.11.0.00 , Adaptor For Centrifugal Lube Oil Filter Cart Part No 6H.021.01.0.00 , Centrifuge Filter & Adapter Assly Cart Part No 6H.021.10.0.00 , Joint -Centrifugal Filter Adopter Cart Part No 6H.021.11.0.00 , Centrifuge Filter And Adaptor Assembly Cart Part No 6H.021.40.0.00 , Leak Off Pipe Sub Assly Cart Part No 6H.023.10.0.00 , Breather Pipe Cart Part No 6H.024.03.0.00 , Clip For Breather Pipe Cart Part No 6H.024.04.0.00 , Hose: Breather Pipe 32 Id Cart Part No 6H.024.05.0.00 , Breather Extension Pipe Cart Part No 6H.024.06.0.00 , Adaptorfor Breather Pipe Cart Part No 6H.024.10.0.Pr , Joint: Adaptor For Breather Cart Part No 6H.024.11.0.00 , Housing: Exh Outlet Cart Part No 6H.026.01.0.00 , Ss Joint: Turbo Outlet Cart Part No 6H.026.02.0.00 , Bracket For Gas Outlet Manifold Cart Part No 6H.027.01.0.00 , Gas Outlet Manifold Cart Part No 6H.027.02.0.00 , Copper Coated Bolt(M10x025) Cart Part No 6H.027.03.0.00 , Gas Outlet Manifold (6K1080 4V, Cpcb Ii) Cart Part No 6H.027.06.0.00 , Bracket For Air Cleaner Cart Part No 6H.028.01.0.00 , Air Pipe: Air Filter-Turbo In Cart Part No 6H.028.02.0.00 , Bracket For Air Pipe Cart Part No 6H.028.03.0.00 , Joint Ss: Turbocharger Cart Part No 6H.029.01.0.00 , Turbocharger Cart Part No 6H.029.06.0.00 , Turbocharger Cart Part No 6H.029.10.0.00 , Clamp For Cac Pipe Cart Part No 6H.030.03.0.00 , Joint: Air Pipe Cart Part No 6H.030.05.0.00 , Air Pipe(Cac To Inlet) Cart Part No 6H.030.07.0.00 , Air Pipe: Turbo To Cac T/C Side Cart Part No 6H.030.08.0.00 , Air Pipe: Turbo To Cac Cart Part No 6H.030.09.0.00 , Bracket For Air Pipe Cart Part No 6H.030.11.0.00 , Bracket Cart Part No 6H.031.01.0.00 , Pulley: Fan 140 Pcd B Sec Cart Part No 6H.031.03.0.00 , Washer (Fan Drive Pulley) Cart Part No 6H.031.06.0.00 , Bearing Housing Sub Assly Cart Part No 6H.031.10.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No 6H.032.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 6H.032.02.0.00 , Engine Mounting Foot (Ge) Cart Part No 6H.033.01.0.00 , Engine Mounting Foot (Fwe) Cart Part No 6H.033.02.0.00 , Engine Mounting Foot (Gear End Side) Cart Part No 6H.033.13.0.00 , Adaptor For Oil Pipe Cart Part No 6H.034.03.0.00 , Lube Oil Inlet Pipe: K20 Turbo Cart Part No 6H.034.04.0.00 , Lube Oil Drain Pipe: K26 Turbo Cart Part No 6H.034.05.0.00 , Lube Oil Drain Pipe: K26 Turbo Cart Part No 6H.034.11.0.00 , Lube Oil Inlet Pipe: K26 Turbo Cart Part No 6H.034.12.0.00 , Lub Oil Inlet Pipefor Turbocharger Cart Part No 6H.034.13.0.Pr , Lub Oil Drain Pipefor Turbocharger Cart Part No 6H.034.14.0.Pr , Pipe: Thermostat To Radiator Cart Part No 6H.036.03.0.00 , Pipe: Radiator To Pump Inlet Cart Part No 6H.036.04.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 6H.036.11.0.00 , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 6H.036.13.0.00 , Engine Foot ( Geae End Side ) Cart Part No 6H.038.01.0.00 , Engine Foot ( Flywheel End Side ) Cart Part No 6H.038.02.0.00 , Oil Seal Housing Cart Part No 6H.045.01.0.00 , Joint: Oil Seal Hsg Cart Part No 6H.045.11.0.00 , Lube Oil Pump Assembly Cart Part No 6H.047.150.0.00 , Lube Oil Pump Assly Cart Part No 6H.047.30.0.00 , Damper ( For Applications At 1800 Rpm & Above ) Cart Part No 6H.050.02.0.00 , Extension Pulley (140 Pcd) Cart Part No 6H.050.03.0.00 , Hose: Water Pipe Cart Part No 6H.056.02.0.00 , Vent Pipe For Radiator Cart Part No 6H.056.03.0.00 , Pipe Thermostat To Radiator Cart Part No 6H.057.01.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No 6H.057.02.0.00 , Air Pipe (Turbocharger To Inlet) Cart Part No 6H.058.01.0.00 , Joint: Air Pipe Cart Part No 6H.058.02.0.00 , Joint (12 Egt Outlet) Cart Part No 6H.058.16.0.Pr , Joint9 5Egt Inlet Cart Part No 6H.058.17.0.Pr , Exhaust Pipe With Bellow (Turbo To Egt Inlet) Cart Part No 6H.058.23.0.Pr , Set Of Copper Washer - 6R1080 Ta Cart Part No 6H.061.10.0.00 , Set Of Joints - 6R1080ta Cart Part No 6H.061.20.0.Sp , Set Of O-Rings: 6R1080ta 125 Kva Cart Part No 6H.061.30.0.00 , Hose: Waterpump Inlet To Heat Exchanger Cart Part No 6H.062.03.0.00 , High Pressure Pipe Assembly (Integral Sleeve 6.35.Dia) Cart Part No 6H.063.180.0.00 , High Pressure Pipe Assembly Cart Part No 6H.063.80.0.00 , Flywheel Housing Cart Part No 6H.065.01.0.00 , Flywheel Assembly Cart Part No 6H.068.10.0.00 , Fuel Pump Vs Cart Part No 6H.073.01.0.00 , Starter 24V Cart Part No 6H.077.01.0.00 , Adapter For Exhaust Silencer Cart Part No 6H.080.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No 6H.081.02.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No 6H.081.03.0.00 , Adaptor On Fuel Filter For Fuel Pipes Cart Part No 6H.081.15.0.00 , Crank Pulley Spa,Two Groove,172 Pcd Cart Part No 6H.084.01.0.00 , Bracket For Magnetic Pickup Cart Part No 6H.085.01.0.00 , Woodward Trim Down Pg Plus System For 6 Cylinder Natural Gas Genset Cart Part No 6H.086.10.0.Pr , H Tcable Set For 6 Cylinder Gas Engine Cart Part No 6H.086.34.0.Pr , Gas Train Assembly Cart Part No 6H.086.45.0.Pr , Adaptor For L.O.P.Switch (M14x1.5 -0.125-27 Nptf) Cart Part No 6H.097.01.0.00 , Fuel Injection Pump For 6K1080 Ta (160 Kva) Cart Part No 6H.100.10.0.00 , Camshaft & Gear Assly Cart Part No 6H.1001.10.0.00 , Actuator Cart Part No 6H.1003.01.0.00 , Ecu: Electronic Governor B1 Cart Part No 6H.1003.02.0.00 , Engine Control Unit Cart Part No 6H.1003.04.0.00 , Voltage Suppressor For B12 Ecu Cart Part No 6H.1003.05.0.00 , Flange Heater To Panel Wiring Harness Cart Part No 6H.1005.40.0.00 , Control Panel Assembly For 6K Electronic Governer With Kg 645 Control Panel Cart Part No 6H.1006.60.0.00 , Engine Wiring Harness Assembly With Kg 545 Cart Part No 6H.1008.30.0.00 , Engine Wiring Harness 6R 125Kva Cart Part No 6H.1008.80.0.00 , Engine Wiring Harness Assembly With Kg 545 Cart Part No 6H.1009.80.0.00 , Engine Wiring Harness For A Bank Cart Part No 6H.1011.130.0.Pr , Engine Wiring Harness For B Bank Cart Part No 6H.1011.140.0.Pr , Engine Wiring Harness Cart Part No 6H.1011.20.0.00 , Engine Wiring Harness S F Kg645 Unit 6R Gas Engine Cart Part No 6H.1011.40.0.Pr , Engine Wiring Harness For 6K Emerald Cart Part No 6H.1011.50.0.Pr , Engine Wiring Harness For 6R 62 5 Kva Png Genset Cart Part No 6H.1011.80.0.Pr , Gear Casing For 6K1080 Cart Part No 6H.1013.01.0.00 , Engine Wiring Harness Sf 6R 125Kva Cart Part No 6H.1014.30.0.Pr , Valve Seat Insert: Inlet Cart Part No 6H.1019.07.9.00 , Valve Seat Insert: Exhaust Cart Part No 6H.1019.08.9.00 , Cylinder Head Assembly6k Engine Cart Part No 6H.1019.50.0.00 , Valve Pair Cart Part No 6H.1019.60.0.00 , Mechanical Fuel Level Indicator Cart Part No 6H.1029.02.0.00 , Engine Wiring Harness For 6K Crdi Cpcb 4+ Cart Part No 6H.1043.10.0.Pr , Engine Wiring Harness For 6K Crdi Cpcb 4+ Optiprime 2X200kvaengine B Cart Part No 6H.1043.100.0.Pr , Engine Wiring Harness For 6K 200Kva Cpcb4engine Cart Part No 6H.1043.20.0.Pr , Wiring Harness Assembly For Fuel Pump Added 4K & 6K Genset Cart Part No 6H.1043.60.0.Pr , Engine Heater Wiring Harness Cart Part No 6H.1043.80.0.Pr , Engine Wiring Harness For 6K Crdi Cpcb 4+ Optiprime 2X200kvaengine A Cart Part No 6H.1043.90.0.Pr , Cold Start Kit Main Assembly For L2 Level Application 12V System6k Cart Part No 6H.1046.80.0.Pr , Cold Start Kit Sub Assembly For L2 12V System6k Cart Part No 6H.1046.90.0.Pr , Engine Heater Wiring Harness 6K Cart Part No 6H.1050.20.0.Pr , Lube Oil Sump Cart Part No 6H.1061.05.0.00 , Dipstick Assembly Cart Part No 6H.1061.10.0.00 , Joint: Suction Tube Cart Part No 6H.1062.07.0.00 , Clam For Suction Pipe Cart Part No 6H.1062.09.0.00 , Clamp Support Cart Part No 6H.1062.11.0.00 , Sub Assembly Of Suction Tube Cart Part No 6H.1062.50.0.00 , Delivery Body Cart Part No 6H.1063.01.0.00 , Delivery Tube Cart Part No 6H.1063.02.0.00 , O Ring: Delivery Tube Cart Part No 6H.1063.04.0.00 , Joint: Delivery Body Cart Part No 6H.1063.05.0.00 , Delivery Tube With Adaptors Assembly Cart Part No 6H.1063.06.0.Pr , Delivery Tube With Flange Cart Part No 6H.1063.10.0.00 , Lube Oil Pump Assly Cart Part No 6H.1064.70.0.00 , Lube Oil Pump Int Gear & Bush Assembly Cart Part No 6H.1065.10.0.00 , Crankcase Sub Assembly Cart Part No 6H.1066.140.0.Spr , Piston Cooling Nozzle Assly Cart Part No 6H.1066.60.0.00 , Joint For Header Cart Part No 6H.1081.03.0.00 , Header (For Lub Oil Cooler & Spin On Filter) (Machining) Cart Part No 6H.1081.05.0.00 , Cover Platefor Cooler Header Cart Part No 6H.1081.06.0.Pr , Header (For Common Rail) Cart Part No 6H.1081.07.0.Pr , Header For Lub Oil Cooler And Filter ( S/F Jacket Water Heater) Cart Part No 6H.1081.08.0.Pr , Header And Cooler Assemblycommon Rail Cart Part No 6H.1081.40.0.Pr , Header And Cooler Assemblycommon Rail Cart Part No 6H.1081.60.0.Pr , Lube Oil Cooler Assemblycommon Rail Cart Part No 6H.1081.70.0.Pr , Delivery Tube Cart Part No 6H.1087.01.0.Pr , Clamp Stripfor Delivery Tube Cart Part No 6H.1087.02.0.Pr , Gasket Cylinder Head & Crankcase Cart Part No 6H.1090.02.0.00 , Gasket (Between Cylinder Head & Crank Case) Cart Part No 6H.1090.04.0.Pr , Cyl Head Assemblycomplete6r1080 4 Valves Cart Part No 6H.1090.30.0.Pr , Cyl Head With Valve Guide Valve Seat Insert 4Vcommon Rail Cart Part No 6H.1090.50.0.Pr , Valve Rocker Assembly Cart Part No 6H.1091.50.0.00 , Rocker Box Cart Part No 6H.1092.06.0.00 , Rocker Cover (Finish) Cart Part No 6H.1093.01.0.00 , O Ring (For Rocker Cover) Cart Part No 6H.1093.12.0.00 , Breather Pipe Cart Part No 6H.1093.14.0.00 , Hoseocv To Drain Cart Part No 6H.1093.23.0.Pr , Joint For Air Inlet Manifold - 6R1080 - 4Valves Cart Part No 6H.1094.02.0.00 , Air Inlet Manifold Cart Part No 6H.1094.03.0.00 , Inlet Manifoldfinish Cart Part No 6H.1094.05.0.00 , H P Pipe Assembly 1Pump To Rail6k1080 4V Cart Part No 6H.1096.76.0.00 , Fuel Pipe Feed Pump To Fuel Filter Id 12 X Od 15 Cart Part No 6H.1097.08.0.Pr , Fuel Pipe Fuel Filter To Fip Id 12 X Od 15 Cart Part No 6H.1097.09.0.Pr , Leak Off Pipe Cart Part No 6H.1097.120.0.00 , Leak Off Pipe From Fip To Tank Id 6 X Od 12 -Polyamide Cart Part No 6H.1097.170.0.00 , Crankcasemonoblockwithout Bearings6r1080 4 Valve Cart Part No 6H.1098.50.0.Pr , Camshaft,Thrust Plate And Camgear Sub Assembly Cart Part No 6H.1099.10.0.Pr , Camshaft Assembly Cart Part No 6H.1099.20.0.00 , Camshaft Assembly Cart Part No 6H.1099.55.0.Pr , Recd Pressure Sensor_Ce10010213 Cart Part No 6H.110.03.0.Sp , Relay_24Vdc_Ce10010336 Cart Part No 6H.110.04.0.Sp , Relay_240Vac_Ce10010335 Cart Part No 6H.110.05.0.Sp , Relay Base_Ce10010436 Cart Part No 6H.110.06.0.Sp , Security Seal_2019 Cart Part No 6H.110.07.0.Sp , Siphon_Siphon0.5Inss Cart Part No 6H.110.08.0.Sp , Buzzer With Flasher_Ce10010287 Cart Part No 6H.110.09.0.Sp , Recd Avm -Silicon Pads (Set Of 4) Cart Part No 6H.110.10.0.Sp , Friction Pu Pads ( Set Of 4) Cart Part No 6H.110.11.0.Sp , Recd Pcd Panel_Chkpcd_V2 Cart Part No 6H.110.12.0.Sp , Recd Temperature Sensor_Ce10010029 Cart Part No 6H.110.13.0.Sp , Bush_Ss304, 0.5X0.25 Inch, Bsp Thread Cart Part No 6H.110.14.0.Sp , Socket_Ss, 0.5 Inch, Bsp Thread Cart Part No 6H.110.15.0.Sp , Socket_Ss, 0.25 Inch, Bsp Thread Cart Part No 6H.110.16.0.Sp , Programming Adapter Usb Converter Cart Part No 6H.110.17.0.Sp , Pcd Controller With Harnesss_Ciplpcdv1.0 Cart Part No 6H.110.18.0.Sp , Hub For Motorpal Fip Cart Part No 6H.1100.03.0.Pr , Oil Drain Pipefip To Sump Cart Part No 6H.1100.05.0.Pr , Lub Oil Sumpshallow Cart Part No 6H.1100.09.0.Pr , Fuel Pipefuel Filter To Fip Cart Part No 6H.1100.11.0.Pr , Fuel Pipefeed Pump To Fuel Filter Cart Part No 6H.1100.12.0.Pr , Leak Off Pipeinjector To Tank Cart Part No 6H.1100.13.0.Pr , Leak Off Pipefuel Filter To Tank Cart Part No 6H.1100.14.0.Pr , High Pressure Pipe Assembly Cart Part No 6H.1104.110.0.00 , Small End Bush For 6K1080 Ta (160 Kva) Cart Part No 6H.111.01.0.00 , Leak Off Pipe Assembly Cart Part No 6H.1124.20.0.00 , Leakoff Assly Cart Part No 6H.1124.30.0.00 , Comb Leakoff Pipe Assly Cart Part No 6H.1124.50.0.00 , Exhaust Bend Cart Part No 6H.1126.02.0.00 , Exhaust Silencer(5, Industrial Type) For 6R1080ta Engines For Fire Fighting Appli Cart Part No 6H.1126.03.0.00 , Air Cleaner F.F. Engines Cart Part No 6H.1128.01.0.00 , Hose: Air Cleaner Cart Part No 6H.1128.02.0.00 , Air Cleaner Assembly, S/F Fire Fighting Cart Part No 6H.1128.11.0.00 , Header For Lub Oil Cooler And Filter ( S/F Jacket Water Heater) Cart Part No 6H.113.01.0.00 , Crank Pulley With Poly V Groves Cart Part No 6H.1130.01.0.00 , Fan Drive Pulley (Poly V Section ,140 Pcd) Cart Part No 6H.1130.02.0.00 , Crank Pulley: Poly V Groove Cart Part No 6H.1130.05.0.00 , Crank Pulley Pcd 140, Pcd 143 Cart Part No 6H.1130.08.0.00 , Fan Pulley (Pcd 130) Poly `V, 7 Pk Cart Part No 6H.1130.09.0.00 , Crank Pulley 150 Pcd,Poly V,6Pk Cart Part No 6H.1130.11.0.00 , Crank Pulley (150 Pcd,Poly V,8Pk) Cart Part No 6H.1130.12.0.Pr , Fan Drive Pulley (140 Pcd Poly-V 7Pk) Cart Part No 6H.1130.14.0.00 , Crank Pulley Cart Part No 6H.1130.16.0.00 , Fip For 6R1080ta Firefighting Application Cart Part No 6H.1134.01.0.00 , Turbocharger For 6R1080ta Spp Firefighting Pump Application(K27.2 3371 Olake 15.21) Cart Part No 6H.1135.01.0.00 , Gasket For Turbo Drain Pipe Cart Part No 6H.1135.02.0.Pr , Water Cooled Cac For 6R1080ta Engine(Fire Fig Cart Part No 6H.1142.01.0.00 , Raw Water Pipecac To H E Cart Part No 6H.1142.12.0.Pr , Sticker(Engine Coolant Heater, 2000W) Cart Part No 6H.1143.02.0.00 , Bracket For Heat Exchanger Mtg Cart Part No 6H.1145.01.0.00 , Hose (H.Exchanger To W.Pump) Cart Part No 6H.1145.03.0.00 , Hose (Thermostat To He) Cart Part No 6H.1145.04.0.00 , Hose(Heat Exchanger To W.Pump) Cart Part No 6H.1145.05.0.00 , Exhaust Bend (For K27 Turbo) Cart Part No 6H.1149.02.0.Pr , Fuel Supply Pipe (From Supply Block To Fuel Pump) Cart Part No 6H.1154.02.0.00 , Leak Off Pipe Assembly Cart Part No 6H.1154.40.0.00 , Bracket For Cooling Line Mtg G E Cart Part No 6H.1156.09.0.Pr , Bracket For Cooling Line Mtg F W E Cart Part No 6H.1156.11.0.Pr , Cooling Line(1 1/4, 12V) Assly For Kfp6r-Uf25(6R1080ta) Engines S/F Flow Switch Cart Part No 6H.1156.50.0.00 , Safety Filter Element Cart Part No 6H.1160.01.0.00 , Primary Filter Element Cart Part No 6H.1160.02.0.00 , Hose Reducer (Air Cleaner To Air Pipe) Cart Part No 6H.1160.08.0.00 , Assembly Of Air Cleaner Cart Part No 6H.1160.40.0.00 , Expansion Bellow Cart Part No 6H.1167.01.0.00 , Diffuser Cart Part No 6H.1167.02.0.00 , Joint: Diffuser Cart Part No 6H.1167.05.0.00 , Bracket For Diffuser Cart Part No 6H.1167.06.0.00 , V Belt: 6R1080t/Ta 7Pk Cart Part No 6H.1171.01.0.00 , Poly V Belt (8 Pk 1206 Epdm) Cart Part No 6H.1171.04.0.Pr , Fuel Pipe Feed Pump Outlet Connection Cart Part No 6H.1175.01.0.00 , Fuel Pipe Feed Pump Inlet Connection Cart Part No 6H.1175.02.0.00 , Anti Vibration Mounts Cart Part No 6H.118.01.0.00 , Anti Vibration Mounts Cart Part No 6H.118.02.0.00 , Anti Vibration Mount For Radiator Cart Part No 6H.118.08.0.00 , Oil Supply Pipe Cart Part No 6H.1187.01.0.00 , Drain Pipe Cart Part No 6H.1187.02.0.00 , Turbo Oil Supply Pipe Cart Part No 6H.1187.04.0.Pr , Air Pipe Cart Part No 6H.1188.01.0.00 , Lube Oil Sump Cart Part No 6H.1189.01.0.00 , Exhaust Manifold6r Cart Part No 6H.1190.01.0.00 , Suction Tube (Sub. Assly.) Cart Part No 6H.1191.10.0.00 , Bypass Filter Cart Part No 6H.1193.02.0.00 , Adaptorfor Bypass Filter Cart Part No 6H.1193.04.0.Pr , Koel Green Alternatorkg125 S T Framekg 34 M 4Sae 2 11 5 415V50 Hz0 8 Pf Cart Part No 6H.1213.11.0.Pr , Alternator 125Kva, 415V, 50Hz, 3Ph, 0.8Pf, Sae1/14 Cart Part No 6H.1213.16.0.Pr , Camtone Wheel Cart Part No 6H.1233.02.0.00 , Counter Sunk Socket Headed Screw Cart Part No 6H.1233.03.0.Pr , Cover For Cambore Cart Part No 6H.1233.04.0.Pr , Fuel Pipe Feed Pump To Filter Cart Part No 6H.1249.01.0.00 , Fuel Pipe Filter To Fip Cart Part No 6H.1249.02.0.00 , Bracket For Fuel Filter Cart Part No 6H.1249.03.0.00 , Bracket (For Leak Off Mtg.) Cart Part No 6H.1250.03.0.00 , Leak Off Pipe Cart Part No 6H.1250.04.0.00 , Leak Off Pipe For Fip & Injector Cart Part No 6H.1250.05.0.00 , Oil Supply Pipe (Header To Fip) Cart Part No 6H.1251.03.0.00 , Oil Supply Pipe Cart Part No 6H.1251.18.0.Pr , Gear Casing4v Common Rail Cart Part No 6H.1257.01.0.Pr , Monoblock Crank Case Sub Assly6r1080 4 Valve Cart Part No 6H.1258.80.0.Pr , Turbocharger Cart Part No 6H.127.01.0.00 , Valve Rocker Assly (6K1080 4V,Common Rail) Cart Part No 6H.1301.10.0.Pr , Thermostat Housing Cart Part No 6H.1351.01.0.Pr , Gasketbetween Thermostat Cover Housing Cart Part No 6H.1351.03.0.Pr , Bracket For Gas Outlet Manifold Cart Part No 6H.137.03.0.00 , Housing (For Exhaust Outlet) Cart Part No 6H.138.01.0.00 , Air Pipe (Air Cleaner To Compressor) Cart Part No 6H.139.01.0.00 , Air Pipe (Turbocharger Side - Radiator Cac 800 X 800) Cart Part No 6H.139.02.0.00 , Lube Oil Inlet Pipe Assly:K27 Cart Part No 6H.141.10.0.00 , Lub Oil Drain Pipe Assembly Cart Part No 6H.141.20.0.00 , Lub Oil Inlet Pipe For S300 Turbocharger Cart Part No 6H.141.26.0.Pr , Lub Oil Inlet Pipe Assly Cart Part No 6H.141.50.0.00 , Lub Oil Inlet Pipefor Turbocharger Cart Part No 6H.141.70.0.Pr , Lub Oil Drain Pipefor Turbocharger Cart Part No 6H.141.80.0.Pr , Exhaust Manifold (Central Piece) Cart Part No 6H.143.02.0.00 , Nozzle Leak Off Pipe (M12 U) Cart Part No 6H.145.10.0.00 , Pipe: Radiator-Pump Inlet Cart Part No 6H.146.11.0.00 , Cylinder Head Assembly Cart Part No 6H.147.20.0.00 , Cylhead Assemblyp Type Cart Part No 6H.147.50.0.00 , Cylhead With Valve Guide And Insertss Type Cart Part No 6H.147.60.0.00 , Cylhead Assemblyp Type Cart Part No 6H.147.70.0.Pr , Injector Cart Part No 6H.155.10.0.00 , Air Delivery Pipe For Ural 375D Cart Part No 6H.165.01.0.00 , Cold Start Kit 6R (L3) Cart Part No 6H.1684.10.0.Sp , Cable Gland Assembly For 6K Engine. Cart Part No 6H.1686.10.0.Pr , Water Connection Hose Pipe Hotstart To Radiator -125 Kva Cart Part No 6H.172.21.0.00 , Water Connection Hose Pipe Hotstart To Engine -125 Kva Cart Part No 6H.172.22.0.00 , Hose: Make Up - 1000 Core Radiator Cart Part No 6H.172.28.0.00 , Con Rod Bearing (Upper) Cart Part No 6H.179.13.0.Pr , Con Rod Bearinglower Cart Part No 6H.179.14.0.Pr , Connecting Rod Assly (With Small End Bush) Cart Part No 6H.179.30.0.Pr , Con Rod Assembly Cart Part No 6H.179.50.0.Pr , Damper Cart Part No 6H.186.01.0.00 , Fuel Pump: 6R1080t V.S. Cart Part No 6H.188.10.0.00 , Fuel Filling Hose For 125 Kva Trailer Mounted Genset Cart Part No 6H.192.04.0.00 , Lfl Sensor ( Low Fuel Level ) 165 Mm Hight Cart Part No 6H.192.14.0.00 , Fuel Injection Pump :6R1080ta-Pg Cart Part No 6H.195.10.0.00 , Fuel Injection Pump For 6R1080t-Pg Cart Part No 6H.196.10.0.00 , Control Panel Schematic For 160Kva, 3Ph With Kg645 Ip+A Cart Part No 6H.2003.70.0.Pr , Control Panel Cart Part No 6H.2003.95.0.Pr , Power Panel Cart Part No 6H.2004.50.0.Pr , Engine Control Panel To Alternator Harness (Fot C.T. & 3Ph. Supply Conn.) Cart Part No 6H.2024.20.0.00 , Ct Wiring Harness For A Bank Cart Part No 6H.2024.80.0.Pr , Ct Wiring Harness For B Bank Cart Part No 6H.2024.90.0.Pr , Inlet Manifold Cart Part No 6H.204.03.0.00 , Rocker Cover Cart Part No 6H.222.10.0.00 , Subassembly Of Suction Tube Cart Part No 6H.224.30.0.00 , Joint: Gear Casing Cart Part No 6H.225.02.0.00 , Camshaft Gear Cart Part No 6H.226.02.0.00 , Thrust Plate Cart Part No 6H.226.03.0.00 , Camshaft, Thrust Plate & Camgear Sub Assly Cart Part No 6H.226.10.0.00 , Lube Oil Sump Cart Part No 6H.227.01.0.00 , Crankshaft Pulley Cart Part No 6H.228.01.0.00 , Front Cover Cart Part No 6H.229.01.0.00 , Monoblock Crankcase Without Bearing Cart Part No 6H.233.120.0.Pr , Crankcase With M Bcaps6h 233 90 0 Pr Cart Part No 6H.233.90.0.Sp , Piston Pin 42.1 Mm Dia For 6K1080ta Cart Part No 6H.247.14.0.00 , Piston Ring Set Cart Part No 6H.247.30.0.00 , Piston Assembly Cart Part No 6H.247.50.0.00 , Piston Assembly Cart Part No 6H.247.60.0.00 , Intermediate Gear Support S F Auto Timer Cart Part No 6H.267.01.0.00 , Gear Casing Cart Part No 6H.273.03.0.00 , Suction Tube Assly Cart Part No 6H.286.10.0.00 , Rotary Fip For 6R1080ta4 Engine169 Hp 2300 Rpm Cart Part No 6H.295.03.0.00 , Rotary Fip: 6R1080ta3 115Hp @ 2300Rpm Cart Part No 6H.295.05.0.00 , Rotary Fip For 6R1080ta1 Engine125 Hp 2300 Rpm Cart Part No 6H.295.07.0.00 , Radiator For 6R1080ta Canopied Genset With Stoneguard Cart Part No 6H.309.20.0.00 , Gear Casing ( For Fmul Engine ) Cart Part No 6H.311.04.0.00 , Con Rod Assly With Se Bush Cart Part No 6H.322.50.0.00 , Coupling 0.37Rb Cart Part No 6H.326.10.9.00 , Fan: 21 Pusher Met Cart Part No 6H.330.01.0.00 , Exh Manifold K27 Turbo Lagged (6H.143.01.0) Cart Part No 6H.342.01.0.00 , Breather Hose Cart Part No 6H.345.04.0.00 , Silencer Cart Part No 6H.352.01.0.00 , Joint: Exhaust Silencer Cart Part No 6H.352.02.0.00 , Flange( At Silencer Inlet And Outlet ) For 6R1080t And 6R1080ta Silent Set Cart Part No 6H.352.03.0.00 , Front Cover Cart Part No 6H.357.01.0.00 , Fan Adaptor Cart Part No 6H.360.01.0.00 , Hose Reducer For Turbo Cart Part No 6H.366.01.0.00 , Hose Silicone 3 For Cac Pipe Cart Part No 6H.366.03.0.00 , Lub Oil Sump (Shallow) Cart Part No 6H.378.01.0.00 , Dipstick Assembly Cart Part No 6H.378.20.0.00 , Crankshaft Assembly Cart Part No 6H.387.20.0.00 , Crankshaft Assembly (With Crank Gear) Cart Part No 6H.387.30.0.00 , Turbocharger For 6K1080ta 4V Cpcb Ii Engine Cart Part No 6H.391.01.0.00 , Turbocharger(For 6K-140 Kva Engine) K27 2964 Mxa 10.21 Cart Part No 6H.391.10.0.00 , Fip:6K1080 Ta Cpcbii Cart Part No 6H.394.02.0.00 , Inline Fip Ea40 2896 00For 6R1080 T150hp 1900Rpmcpcbii Engine Cart Part No 6H.394.03.0.00 , 4440 Motorpal Fipfor 6R1080ta 3000Rpm Cpcb Ii Engine Cart Part No 6H.394.05.0.Pr , Safety Air Filter Element Cart Part No 6H.411.01.0.00 , Primary Air Filter Element Cart Part No 6H.411.02.0.00 , Air Cleaner Assly+Safety Elemt Cart Part No 6H.411.10.0.00 , Air Cleaner Assly+Safety Elemt Cart Part No 6H.411.20.0.00 , Straight Rubber Hose Cart Part No 6H.412.03.0.00 , Hose For Air Suction Pipe Cart Part No 6H.412.06.0.00 , Air Cleaner Assly Wo Elemt Cart Part No 6H.412.10.0.00 , Hose: Air Cleaner Cart Part No 6H.412.11.0.00 , Hose: Air Cleaner Cart Part No 6H.412.12.0.00 , Air Cleaner Primary Element Cart Part No 6H.413.02.0.00 , Radial Seal Air Cleaner Assly,15 Cu Meter Cart Part No 6H.413.10.0.00 , Air Cleaner Assembly Cart Part No 6H.413.30.0.00 , Air Filter Primary Cart Part No 6H.413.32.0.00 , Piston Cooling Nozzle Assly Cart Part No 6H.426.10.0.00 , Dial Type Mechanical Fuel Level Gauge275mm Ht Cart Part No 6H.457.05.0.00 , Hose: Air Cleaner Cart Part No 6H.466.47.0.00 , Spacer For Starter Cart Part No 6H.466.51.0.00 , Coolant Pipe Fordosing Module Out To Radiator In 2 Cart Part No 6H.477.101.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Cart Part No 6H.477.102.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Cart Part No 6H.477.103.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) Cart Part No 6H.477.104.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) Cart Part No 6H.477.106.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 4 Cart Part No 6H.477.107.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 1 Cart Part No 6H.477.108.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 2 Cart Part No 6H.477.109.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 3 Cart Part No 6H.477.111.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 4 Cart Part No 6H.477.112.0.Pr , Bracket Assembly For Pipe Clamping On Dosing Module Cart Part No 6H.477.113.0.Pr , Fuel Inlet Pipe (Tank To Pre-Filter) Cart Part No 6H.477.114.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Cart Part No 6H.477.117.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2 Cart Part No 6H.477.118.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 5 Cart Part No 6H.477.119.0.Pr , O-Ring Cart Part No 6H.477.140.0.Sp , Filler Filter Cart Part No 6H.477.141.0.Sp , Drain Plug Cart Part No 6H.477.142.0.Sp , Air Vent Cart Part No 6H.477.143.0.Sp , Filling Neck Cart Part No 6H.477.144.0.Sp , Locking Cap Cart Part No 6H.477.145.0.Sp , Hose: Radiator Outlet To Water Pump Inlet Cart Part No 6H.477.15.0.00 , Aluminium Radiator Assly Cart Part No 6H.477.22.0.00 , Aluminium Radiator Assembly Cart Part No 6H.477.23.0.00 , Recovery Bottel 3 5 Ltrs Cart Part No 6H.477.26.0.Pr , 25L Ad Blue Tank Assembly Cpcb4 Cart Part No 6H.477.27.0.Pr , Metalic Pipe Thermostat To Rad In Cart Part No 6H.477.31.0.00 , Hose From Radiator To Pipe Cart Part No 6H.477.32.0.00 , Hose For Make Up Connection Cart Part No 6H.477.33.0.00 , Clamp For 160 Kva Cart Part No 6H.477.37.0.00 , Plate Cart Part No 6H.477.38.0.00 , Hose Between Pump Inlet And Radiator Pipe Outlet Cart Part No 6H.477.47.0.Pr , Fan 30`` Cart Part No 6H.477.52.0.Pr , Aluminium Radiator Assembly Cart Part No 6H.477.53.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Cart Part No 6H.477.94.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Cart Part No 6H.477.96.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 1 Cart Part No 6H.477.97.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 3 Cart Part No 6H.477.98.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-1) Cart Part No 6H.477.99.0.Pr , Engine Mounting Foot (Gear End Side) For 6R1080 Gas Genset Cart Part No 6H.487.01.0.00 , Air Cleaner Wo Safty Elemt 6M3 Cart Part No 6H.488.10.0.00 , Aluminium Radiator: 6R1080ta Cart Part No 6H.501.10.0.00 , Hose: Make Up Connection Cart Part No 6H.502.02.0.00 , Hose For Radiator Out To Water Pump In Cart Part No 6H.502.11.0.00 , Stay Rod (For Radiator) Cart Part No 6H.502.12.0.00 , Hose Thermostat To Radiator Inlet (45X45x155l) Cart Part No 6H.502.13.0.00 , Radiator Cart Part No 6H.502.40.0.00 , Lower Clamp For New Gear Casing6h 972 Cart Part No 6H.504.11.0.00 , Main Fuel Filter Cart Part No 6H.508.03.0.Pr , Pre Fuel Filter Cart Part No 6H.508.04.0.Pr , 6H 508 05 0 Pr Cartridge For Filter 6H 508 03 0 Pr 083689901 D 01 Cart Part No 6H.508.05.0.Pr , 6H 508 06 0 Pr Cartridge For Filter 6H 508 04 0 Pr E083689902 D 01 Cart Part No 6H.508.06.0.Pr , 500 Hrs - B Check Maintenance Kit Cart Part No 6H.508.16.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 6H.508.17.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No 6H.508.18.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No 6H.508.19.0.Sp , Cac Outlet Pipe Stage 1Cac To Inlet Manifold S F Schwing Bp2800 Cart Part No 6H.510.03.0.Pr , Cac Outlet Pipe Cac To Inlet Manifold Stage 2 Cart Part No 6H.510.04.0.00 , Rubber Hose For Cac Inlet Pipe Cart Part No 6H.510.07.0.00 , Rubber Hose For Cac Outlet Pipe Cart Part No 6H.510.08.0.00 , Radiator &Cac Assembly.(S/F - Schwing C.P) Cart Part No 6H.510.10.0.00 , Water Pipe Thermostat To Radiator Cart Part No 6H.510.11.0.00 , Stay For Radiator Cart Part No 6H.510.12.0.00 , Air Pipe (Turbocharger To Cac) Cart Part No 6H.516.01.0.00 , Air Pipe (Cac To Air Inlet) Cart Part No 6H.516.02.0.00 , Air Pipe Bend Pipe To Radiator Cart Part No 6H.516.04.0.00 , Air Pipe Cart Part No 6H.516.08.0.00 , Cac Pipe Cold Side Cart Part No 6H.516.21.0.Pr , Engine Wiring Harness Assembly Cart Part No 6H.520.10.0.00 , Set Of Joints Cart Part No 6H.522.40.0.Sp , Radiator Fan (22) Cart Part No 6H.540.01.0.00 , Expansion Bellow Cart Part No 6H.541.01.0.00 , Exhaust Bend (S/F- Schwing) Cart Part No 6H.546.01.0.00 , Spacer: Silencer - Turbocharger Cart Part No 6H.548.04.0.00 , Joint:Spacer & Silencer Cart Part No 6H.548.05.0.00 , Assembly Exhaust Silencer 6R1080ta Bs Iii Cart Part No 6H.548.10.0.00 , Silencer Clamp- 275 Dia Cart Part No 6H.553.21.0.00 , Fan Assly:22.5/6-6/2Zr/40/Pag/Pusher Cart Part No 6H.554.10.0.00 , Coolant Level Sensor For 6K Crdi Cart Part No 6H.565.13.0.00 , Breather Hose Cart Part No 6H.599.02.0.00 , Pipe Metallicfrom Air Cleaner To Tc Cart Part No 6H.599.04.0.00 , Hose: Air Cleaner Cart Part No 6H.599.05.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No 6H.599.11.0.00 , Fuel Return Pipe Cart Part No 6H.599.12.0.00 , Actuator & Ecu Mtg. Bracket Cart Part No 6H.599.13.0.00 , Fuel Pipe Feed Pump To Pre-Filter Cart Part No 6H.599.14.0.00 , Drain Pipe Cart Part No 6H.599.15.0.00 , Link M6x1 Cart Part No 6H.599.17.0.00 , Hose: Radiator Inlet Cart Part No 6H.599.21.0.00 , Radiator Outlet Hose Cart Part No 6H.599.22.0.00 , Fuel Pipe (Pre-Filter To Tank Unit Cart Part No 6H.599.23.0.00 , Fuel Pipe From Feed Pump To Pre Filter Cart Part No 6H.599.24.0.00 , Fuel Pipe From Feed Pump To Pre Filter Cart Part No 6H.599.29.0.Pr , Suction Hose Cart Part No 6H.599.36.0.Pr , Pvc Pipe For Air Cleaner Cart Part No 6H.599.42.0.Pr , Radiator Outlet Hose Cart Part No 6H.599.43.0.Pr , Bracket For Stop Solenoid Mtg. Cart Part No 6H.599.46.0.Pr , Linkm6 Cart Part No 6H.599.48.0.Pr , Fuel Inlet Pipe Cart Part No 6H.599.51.0.Pr , Fuel Inlet Pipeboth Side Union Nut Cart Part No 6H.599.53.0.Pr , Fuel Return Pipe Cart Part No 6H.599.74.0.Pr , Junction Box Support Bracket Cart Part No 6H.599.76.0.Pr , Fuel Pipe (From Tank To Nrv) Cart Part No 6H.599.84.0.Pr , Fuel Pipe (From Nrv To Pre-Filter) Cart Part No 6H.599.86.0.Pr , Kit For Electrical Fuel Feed Pump Fitment In 6K Cart Part No 6H.599.90.0.Sp , Wiring Harnessassembly For Starter Side Panel Cart Part No 6H.610.10.0.00 , Exhaust Silencer Cart Part No 6H.621.10.0.00 , Rh Lock With Catcher: 50Mm Thk Cart Part No 6H.623.25.0.00 , Lh Lock With Catcher: 50Mm Thk Cart Part No 6H.623.30.0.00 , Fuel Pump Gear Cart Part No 6H.652.01.0.00 , Hub For Motorpal Fip Fitment Cart Part No 6H.652.02.0.00 , Starter 12V 3Kw Cart Part No 6H.675.01.0.00 , Control Relay Cart Part No 6H.715.11.0.00 , Exhaust Temperature Sensor With 2Pin Connector, Cart Part No 6H.715.31.0.00 , Koel Green Alternatorkg 50 S Tframe Ls Kg423ksae 3 11 5 415 V50 Hz0 8 Pf Cart Part No 6H.801.05.0.Pr , Current Transformer(Set Of 3 Ct) 300/5A For Frame 254 Cart Part No 6H.831.09.0.00 , Fanhpd Rating 70 160 Kva Ag3141890000 Frame Kg44 3 Cart Part No 6H.831.16.0.00 , Wound Exciter Rotor Scl35rating 50 Kva 1Ph82 5 100 Kva Cart Part No 6H.831.17.0.00 , Wound Exciter Stator Scl35rating 50 Kva 1Ph 82 5 100 Kva Cart Part No 6H.831.18.0.00 , Wound Exciter Rotorrating 62 5 Kva 1 Ph125 160 Kva Cart Part No 6H.831.19.0.00 , Wound Exciter Stator-Lcl 50, Rating-62.5 Kva 1Ph, 125-160 Kva, (Sem443st004b), Fram Cart Part No 6H.831.21.0.00 , Diode Assembly Rating 70 60Kvaaem000re137bframe Kg44 3 Cart Part No 6H.831.22.0.00 , Nde End Shieldrating 70 160 Kva Ag2140080000 Frame Kg44 3 Cart Part No 6H.831.26.0.00 , Coupling Disc11 5Rating 70 160 Kva Pde352da021b Frame Kg44 3 Cart Part No 6H.831.27.0.00 , Avr- D350 Cart Part No 6H.831.30.0.00 , R450 To D350 Retro Fitment Kit For Kg45 Frame Cart Part No 6H.831.40.0.00 , Mccb 3 Pole125a Cart Part No 6H.846.05.0.00 , Relay Board 4 Channel Cart Part No 6H.846.06.0.00 , Relay Board 4Ch, 2 C/O,24 Vdc Cart Part No 6H.846.07.0.00 , Relay 100 Amp.Type- Bgr 213/24Vdc Cart Part No 6H.846.35.0.00 , Battery Charger: 10A 24 Vdc Cart Part No 6H.849.09.0.00 , 4 Pin Connector3102r 14S 2 P Sqg C C Cart Part No 6H.849.31.0.00 , Generator Control Unit Model Dse 4522 A2 Cart Part No 6H.877.14.0.Pr , On/Ff Selector Sw. Cart Part No 6H.880.12.0.00 , Emergency Stop Pb With Nc Element Cart Part No 6H.880.13.0.00 , Door Lock, Type-Dm3wl / Equiv - Die Cast , Standard Grip 30Mm Cart Part No 6H.880.16.0.00 , On/Ff Selector Sw.(With No Element ) Cart Part No 6H.880.32.0.00 , On/Off Selector Switch With No Element Cart Part No 6H.880.41.0.00 , Emg Stop With No Element Cart Part No 6H.880.42.0.00 , Emg Stop With Nc Element Cart Part No 6H.880.43.0.00 , 1Ncs2 Element Cart Part No 6H.880.45.0.00 , Avr-Mx 321 Type For Stamford Alternator 160 Kva At Ntp, 415 Volts, 50 Hz, 3 Phase, Cart Part No 6H.892.06.0.00 , Air Cleaner Mounting Bracket Cart Part No 6H.899.01.0.00 , Hose: Air Cleaner Cart Part No 6H.899.02.0.00 , Wiring Harness Asys F 6R1080ta125 Kva Cart Part No 6H.900.10.0.00 , Koel Green Alternatorkg160 S T Framel Kg 44 3 H Sae 2 11 5 415V50 Hz0 8 Pf Cart Part No 6H.901.03.0.Pr , Diode Assembly Kg 45 Cart Part No 6H.901.11.0.00 , Wound Exciter Rotor Kg 45 Cart Part No 6H.901.12.0.00 , Wound Exciter Stator Kg 45 Cart Part No 6H.901.13.0.00 , Terminal Bar For Kg 45 Cart Part No 6H.901.14.0.00 , Coupling Disc 14For Kg 45 Cart Part No 6H.901.17.0.00 , Nde Shield For Kg 45 Cart Part No 6H.901.21.0.00 , Koel Green Alternatorcoastalhumid Environment Kg160 S T Framel Kg 44 3 H Cart Part No 6H.901.28.0.Pr , De Adaptor Kg 40 (Sae 2) Cart Part No 6H.901.32.0.00 , Droop Current Transformer Kg 47.2 Cart Part No 6H.901.34.0.00 , 23-Pin Connector Ms-3102-R-32-6-P (Male Type Pins)+C&C+Sqg Cart Part No 6H.902.25.0.00 , Wiring Haness Assembly (Fire Fighting) Cart Part No 6H.902.30.0.00 , Temperature Switch Engine Coolant Cart Part No 6H.902.31.0.00 , Temperature Switch Engine Coolant Low Cart Part No 6H.902.32.0.00 , Temperature Switch Raw Water Cart Part No 6H.902.33.0.00 , Wiring Harness Assembly 6R1080ta Fm_Ul New Cart Part No 6H.902.35.0.00 , Flow Switch 4Rta Cart Part No 6H.903.11.0.Pr , Raw Water Flow Switch R1080ta Fm_Ul New Cart Part No 6H.903.13.0.Pr , Raw Water Flow Switch Sl90 Fm Ul New Cart Part No 6H.903.14.0.Pr , Engine Wiring Harness: 6R Cpcb Cart Part No 6H.924.20.0.00 , Wiring Harness (For Kpc 6H.2575) Cart Part No 6H.931.40.0.00 , Common Rail For 6K1080tae Project Cart Part No 6H.9408.01.0.00 , Hose: Air Cleaner Cart Part No 6H.949.02.0.00 , H T Cable Set Cart Part No 6H.956.13.0.00 , Distributor Driving Shaft For 6R Gas Engine Cart Part No 6H.956.28.0.00 , Gear Casing Cart Part No 6H.972.01.0.00 , Power Cables For A Bank Cart Part No 6H.977.130.0.Pr , Power Calbes For B Bank Cart Part No 6H.977.140.0.Pr , Canopy Wiring Harness For Optiprime 2 X 200Kva Cpcb4 Genset Cart Part No 6H.979.90.0.Pr , Current Transfarmor 200/5, 5 Va Cart Part No 6H.980.05.0.00 , Single Pole Mcb 16A Cart Part No 6H.983.11.0.00 , Shaft For Lube Oil Pump Intermediate Gear Cart Part No 6H.985.07.0.00 , Lube Oil Pump Assly Cart Part No 6H.985.30.0.00 , Joint: Suction Flange Cart Part No 6H.986.05.0.00 , Sub Asm Of Suction Tube Cart Part No 6H.986.30.0.00 , Funnel Filter Cart Part No 6H.986.31.0.00 , Funnel Filter 55 Lpm Cart Part No 6H.986.32.0.Tol , Funnel Filter 18.9 Lpm Cart Part No 6H.986.34.0.Sp , Gasket (Between Bearing Housing And Pump Volute) Cart Part No 6H.990.07.0.Pr , Gasketbet Crankcase And Pump Volute Cart Part No 6H.990.08.0.Pr , Pulley (For Water Pump) Cart Part No 6H.990.09.0.Pr , Water Pump Aasembly Cart Part No 6H.990.20.0.Pr , Fuel Pump 6R1080tc 169 Hp @ 2300 Rpm_F 002 Aoz 651 Cart Part No 6H.996.02.0.00 , Modification Kit For Oil Fuel Mixing Issue Cart Part No 6H.999.02.0.Sp , Main Bearing Kit For Bio Gas Cart Part No 6H.999.03.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3553... - 6R1080ta Cart Part No 6H.999.07.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8419... - 6K1080ta G2 Cart Part No 6H.999.08.0.Sp , Wet Pm Kit (W/O Oil) For 6H.2516 - R 1080 Ta Cart Part No 6H.999.21.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8303, 6H.8416 Cart Part No 6H.999.23.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3415, 6H.3531, 6H.3532, 6H.3533 - 6R1040 Cart Part No 6H.999.24.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3416, 6H.3445, 6H.3545, 6H.3552 - 6R1040 Cart Part No 6H.999.25.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3545 - 6R1080ta Cart Part No 6H.999.28.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8404,6H.5255, 6H.9460, 6H.9467, 6H.5245,- 6K1080ta G2 Cart Part No 6H.999.49.0.Sp , Wet Pm Kit (W/O Oil) For 6H.4435, 4H.3423, 6H.3532- 6R1080ta Cart Part No 6H.999.58.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3501 - 6R1080ta Cart Part No 6H.999.59.0.Sp , Major Overhal Kit For 6R1080 Bsiii Cart Part No 6H.999.60.0.00 , Wet Pm Kit (W/O Oil) For 6H.8425 - 6K1080ta G2 Cart Part No 6H.999.67.0.Sp , Wet Pm Kit (W/O Oil) For 6H.8422 - 6K1080ta G2 Cart Part No 6H.999.68.0.Sp , Wet Pm Kit (W/O Oil) For 6H.5045, 6H.5245 - 6K1080 Cart Part No 6H.999.70.0.Sp , Wet Pm Kit (W/O Oil) For 6H.3502..., 6H.2501... - 6R1080ta Cart Part No 6H.999.96.0.Sp , Doc Catalyst9 5Dia X 5Length15 G Cft5 1 Pt Pdfresh Cart Part No 6H.Egt4.10.0.Pr , 9 5Gasket Doc To Mixer 82429423 Cart Part No 6H.Egt4.23.0.Pr , Supply Module B444 606 940Sm 2 2 Evo Bl12 V9 Bar Cart Part No 6H.Egt4.24.0.Pr , 6H Egt4 28 0 Pr 9 5Egt System Assemblycpcb 4 Cart Part No 6H.Egt4.28.0.Sp , Wire Braided Pipe From Jacketed Leakoff To Fuel Collector Cart Part No 6H.M005.03.0.00 , Fuel Pipefuel Filter To Fuel Pump Cart Part No 6H.M081.02.0.00 , Fuel Pipefeed Pump To Fuel Filter Cart Part No 6H.M081.03.0.00 , Hose Thermostat To He Cart Part No 6H.M400.05.0.00 , Hose Thermostat To He Cart Part No 6H.M400.06.0.00 , Hose Between Cac Out To He In Cart Part No 6H.M400.72.0.00 , Heat Exchanger For 6R Fishing Engine Cart Part No 6H.M409.01.0.00 , Heat Exchanger For 6R Fishing Engine D101 Cart Part No 6H.M409.12.0.00 , Air Cleaner Model Jjm 02 Cart Part No 6H.M412.05.0.00 , K Sealent (80 Ml) Cart Part No 82.060.10.0.80 , Rust Buster Cart Part No 82.060.10.0.92 , Genset Alternator De/Nde Bearing Grease (500 Gm) For Power Car Application Cart Part No 82.170.50.0.50 , Mechnical Inter Lock Cart Part No Acl.0001.007.0.00 , Surge Suppressor Koel Make For Frame 1 Cart Part No Acl.0001.008.0.00 , Contactor Auxillary 1 No 1 Nc Contact For Top For Frame 1 , Koel Make (Type : Ku Cart Part No Acl.0001.110.0.00 , Mechnical Inter Lock Cart Part No Acl.0002.007.0.00 , Surge Suppressor , Koel Make For Frame 2( Type: Kas-3 ) Cart Part No Acl.0002.008.0.00 , Contactor Auxillary 1 No 1 Nc Contact For Top For Frame 2 , Koel Make (Type : Ka Cart Part No Acl.0002.110.0.00 , Mechnical Inter Lock Koel Make For Frame 3Typekar 180 Cart Part No Acl.0003.007.0.00 , Contactor Auxillary Cart Part No Acl.0003.220.0.00 , Contactor Auxillary 1 No 1 Nc Contact For Side For Frame 4 Koel Maketype Ka Cart Part No Acl.0004.110.0.00 , Mccb Auxuliary Shunt Release Contact Upto 100 Amp Koel Make For Type Kll1 Cart Part No All.0100.003.0.00 , Mccb Spreaders 100 125Amp3 Polekoel Make For Type Kll1 Set Of 6With Hardw Cart Part No All.0100.036.0.00 , Mccb Spreaders 100 Amp, 4 Pole, Koel Make For Type Kll1 ( Set Of 8) With Hardwar Cart Part No All.0100.046.0.00 , Mccb Auxuliary Shunt Release Contact 125-250 Amp Cart Part No All.0250.003.0.00 , Mccb Spreaders 250 Amp, 3 Pole Cart Part No All.0250.036.0.00 , Mccb Spreaders 250 Amp4 Polekoel Make For Type Kll3 Set Of 8With Hardware Cart Part No All.0250.046.0.00 , Mccb Auxuliary Shunt Release Contact 400-800 Amp Cart Part No All.0800.003.0.00 , Mccb Rotary Handle Koel Make, For Type Kll5 Cart Part No All.0800.005.0.00 , Mccb Spreaders 800 Amp3 Polekoel Make For Type Kll5set Of 6With Hardware Cart Part No All.0800.036.0.00 , Mccb Rotary Handle Koel Make, For Type Kll6 Cart Part No All.1250.005.0.00 , Regulating Sway Bar Cart Part No Ap1.001.12.0.Pr , Oil Safeguard Switch Cart Part No Ap1.001.15.0.Pr , Oil Level Switch Assembly Cart Part No Ap1.001.20.0.00 , Governor Gear Cup Assy Cart Part No Ap1.001.30.0.00 , Front Oil Seal 25X41 25X6 Cart Part No Ap1.002.02.0.00 , Crancase Cover Gasket Cart Part No Ap1.002.04.0.00 , Dipstick With Seal Cart Part No Ap1.002.06.0.Pr , Cylinder Head Gasket Cart Part No Ap1.003.05.0.00 , Exhaust Gasket Cart Part No Ap1.003.06.0.00 , Cylinder Head Assembly Cart Part No Ap1.003.10.0.00 , Pusher Cart Part No Ap1.005.06.0.Pr , Starter Motor Solenoid Cart Part No Ap1.006.04.0.00 , Starter Motor Assembly Cart Part No Ap1.006.10.0.00 , Recoil Starter Assembly Cart Part No Ap1.007.20.0.Pr , Filter Element Cart Part No Ap1.008.02.0.00 , Air Cleaner Assembly Cart Part No Ap1.008.10.0.00 , Filter Element Cart Part No Ap1.008.11.0.00 , Alternator Fan Cart Part No Ap1.009.03.0.00 , Rotor Fan Cart Part No Ap1.009.121.0.Pr , Alternator Rear Frame Cart Part No Ap1.009.15.0.00 , Voltage Regulator- 2 Kva Cart Part No Ap1.009.42.0.00 , Rotor Rear Fan Cart Part No Ap1.009.44.0.Pr , 2 6Kw Pm Alternator Assembly Cart Part No Ap1.009.55.0.Pr , Pm Alternator Module Cart Part No Ap1.009.64.0.Pr , Ignition Coil Cart Part No Ap1.010.01.0.00 , Ignition Coil Assembly Cart Part No Ap1.010.10.0.00 , Charge Coil Assembly Cart Part No Ap1.010.20.0.Pr , Muffler Cart Part No Ap1.011.01.0.00 , Catcon Element Cart Part No Ap1.011.18.0.Pr , Muffler For 2.8Kw Pmg Cart Part No Ap1.011.22.0.00 , Exhaust Gasket Muffler Cart Part No Ap1.011.29.0.Pr , Catcon & Catcon Pipe Assly For 2.6Kw Ccp196 (S/F Pmg Kcc) Cart Part No Ap1.011.45.0.Spr , Catcon And Catcon Pipe Assembly Cart Part No Ap1.011.50.0.Spr , Anti Vibration Mount708a Mix 01 Yellow 15 4 To 5 Alternator Side Cart Part No Ap1.012.01.0.Pr , Anti Vibration Mount708a Mix 02 Green 25 4 To 5 Engine Side Cart Part No Ap1.012.02.0.Pr , Piston Assembly Cart Part No Ap1.013.10.0.Pr , Carburetor Assembly Cart Part No Ap1.014.10.0.00 , Carburettor Metal Gasket Cart Part No Ap1.014.12.0.00 , Carburettor Connecting Block Gasket Cart Part No Ap1.014.13.0.00 , Carburettor Connecting Block Cart Part No Ap1.014.14.0.00 , Carburettor Metal Gasket Cart Part No Ap1.014.15.0.00 , Fine Regulating Spring Cart Part No Ap1.015.04.0.Pr , Back Spring Cart Part No Ap1.015.05.0.Pr , Ignition Switch Cart Part No Ap1.016.03.0.00 , Mcb 9 Amp Cart Part No Ap1.016.08.0.00 , Engine Power Harness For 2 8Kw Pmg Petrol Cart Part No Ap1.016.45.0.Pr , Regulator Charger Cart Part No Ap1.018.04.0.Pr , Fuel Gauge Cart Part No Ap1.022.05.0.00 , Fuel Tank Assembly 6.5 Ltr Cart Part No Ap1.022.10.0.00 , Fuel Filter Cart Part No Ap1.022.13.0.00 , Fuel Cock Cart Part No Ap1.022.14.0.00 , Fuel Cock Cart Part No Ap1.022.14.0.Pr , Fuel Filter And Fuel Pipe Assembly Cart Part No Ap1.022.35.0.Pr , Choke Cable Assembly Cart Part No Ap1.023.65.0.00 , Lub Oil Drain Pipe Assembly Cart Part No Ap1.026.11.0.00 , Axle Cart Part No Ap1.101.14.0.00 , Circlip Cart Part No Ap1.101.17.0.00 , Wheel-160 Cart Part No Ap1.101.18.0.00 , Digital Display Unit (Voltage-Frequency-Cummulative Hours-Running Hours) Cart Part No Ap1.120.003.0.00 , Complete Engine Assembly With 2 6Kw Pm Alternator Cart Part No Ap1.7001.100.0.Pr , Wet Pm Kit (W/O Oil) For Ap1.2001 - Ccp196 Cart Part No Ap1.999.88.0.Sp , Cylinder Head Gasket Cart Part No Ap5.003.05.0.Pr , Cylinder Head Cover Gasket Cart Part No Ap5.003.07.0.Pr , Recoil Starter Assembly Cart Part No Ap5.007.20.0.Pr , Ignition Coil Assembly Cart Part No Ap5.010.10.0.Pr , Carburetor Assembly Cart Part No Ap5.014.20.0.00 , Carburetor Gasket Cart Part No Ap5.014.46.0.00 , Stepper Motor Assy Cart Part No Ap5.014.47.0.00 , Gasket For Muffler Cart Part No Ap5.016.11.0.Pr , Oil Safeguard Switch Cart Part No Ap5.017.07.0.Pr , Amf Panel Assembly For 20 To 25 Kva3phamfi Wall Mounting Cart Part No Apk.0253.10.0.00 , Amf Panel Assembly For 20 To 30 Kva1phamfi Wall Mounting Cart Part No Apk.0301.10.0.00 , 63 Amp 4 Pole Rear Mounting Chageover Switch Koel Cart Part No Apk.0400.006.0.Pr , Amf Panel Assembly For 45 Kva3phamfi Wall Mounting Cart Part No Apk.0453.10.0.00 , Con Rod Bearing: 6R1080 Std Cart Part No B.006.4.00.003 , Con Rod Bearing: 6R1080 0.25 Cart Part No B.006.4.00.013 , Bearing C R Kir 6R 10800 50 Cart Part No B.006.4.00.023 , Connecting Rod Bearing 030 Cart Part No B.006.4.00.033 , Connecting Rod Bearing 040 Cart Part No B.006.4.00.043 , Bearing C R Kir 4R Tastd Cart Part No B.006.4.30.003 , Bearing C Rkir Ra2 B 012 4 00 023 Cart Part No B.012.4.00.023 , Brg C/R Cart Part No B.019.3.00.003 , Brg C/R 010Kir Tv1 Cart Part No B.019.3.00.013 , Brg C R020kir Tv1 Cart Part No B.019.3.00.023 , Connecting Rod Bearing Cart Part No B.019.3.10.003 , Con Rod Bearing Ra3 Cart Part No B.038.4.00.003 , Con Rod Bearing Ra3 Cart Part No B.038.4.00.013 , Con Rod Bearing: Ra3 Cart Part No B.038.4.00.023 , Con Rod Bearing: Ra3 030 Cart Part No B.038.4.00.033 , Connecting Rod Bearing 010 Cart Part No B.040.4.00.013 , Connecting Rod Bearing 020 Cart Part No B.040.4.00.023 , Con Rod Bearing: Sl90 Cart Part No B.055.4.00.003 , Connecting Rod Bearing 010 Cart Part No B.055.4.00.013 , Con Rod Bearing: Sl90 250Kva Cart Part No B.055.4.10.003 , Bearing C R Kir Sl90 250Kva0 25 Cart Part No B.055.4.10.013 , Bearing C R Kir Sl90 250Kva0 50 Cart Part No B.055.4.10.023 , Connecting Rod Bearing 030 U/S Cart Part No B.055.4.10.033 , Con Rod Bearing : Ha394 Cart Part No B.073.4.00.003 , Con Rod Bearing : Ha394 Cart Part No B.073.4.00.013 , Con Rod Bearing: Ha394 Cart Part No B.073.4.00.023 , Con Rod Bearing: Ha394 030 Cart Part No B.073.4.00.033 , Connecting Rod Bearing 040 Cart Part No B.073.4.00.043 , Con Rod Bearing :Ha394 Std Cart Part No B.073.4.10.003 , Con Rod Bearing: Ha394 0.25 Cart Part No B.073.4.10.013 , Con Rod Bearing: Ha394 020 U/S Nick Cart Part No B.073.4.10.023 , Con Rod Bearing: Ha394 030 U/S Nick Cart Part No B.073.4.10.033 , Con Rod Bearing: Ha 494 Cart Part No B.074.4.00.003 , Con Rod Bearing: Ha494 Cart Part No B.074.4.00.013 , Con Rod Bearing: Ha 494 Cart Part No B.074.4.00.023 , Con Rod Bearing: Ha494 Cart Part No B.074.4.00.033 , Con Rod Brg Ha494 Std Cart Part No B.074.4.10.003 , Con Rod Bearing Ha494 0.25 Cart Part No B.074.4.10.013 , Con Rod Bearing: Ha494 0.50 Cart Part No B.074.4.10.023 , Con Rod Bearing: Ha494 030 U/S Nick Cart Part No B.074.4.10.033 , Con Rod Bearing: Ha694 Cart Part No B.075.4.00.003 , Con Rod Bearing: Ha694 010 Cart Part No B.075.4.00.013 , Connecting Rod Bearing 020 Cart Part No B.075.4.00.023 , Connecting Rod Bearing 030 Cart Part No B.075.4.00.033 , Con Rod Bearing: Ha694 Std Nick Cart Part No B.075.4.10.003 , Con Rod Bearing: Ha694 010 U/S Nick Cart Part No B.075.4.10.013 , Connecting Rod Bearing 020 U/S Cart Part No B.075.4.10.023 , Con Rod Bearing: Ha294 Cart Part No B.093.4.00.003 , Con Rod Bearing: Ha294 010 Cart Part No B.093.4.00.013 , Connecting Rod Bearing 020 Cart Part No B.093.4.00.023 , Con Rod Bearing: Ha294 Std Nick Cart Part No B.093.4.10.003 , Con Rod Bearing: Ha294 010 U/S Nick Cart Part No B.093.4.10.013 , Con Rod Bearing: Dv10 Std Cart Part No B.547.4.00.003 , Kir 4R810 Ta B E Brg T4160030std Cart Part No B.552.0.10.003 , Bearing Big End: 4R810 Std Cart Part No B.552.4.00.003 , Con Rod Bearing: 4Rta Std Cart Part No B.584.4.00.003 , Connecting Rod Bearing 025 Cart Part No B.584.4.00.013 , Kir 4Rta C R Brg0 50 04692020 Cart Part No B.584.4.00.023 , Connecting Rod Bearing 075 Cart Part No B.584.4.00.033 , Kir 4Rta C/R Brg, 1.00, (04692020) Cart Part No B.584.4.00.043 , Con Rod Bearing: 6Tra Std Cart Part No B.584.4.10.003 , Con Rod Bearing: 6Rta 0.25 Cart Part No B.584.4.10.013 , Kir 6Rta C R Brg0 50 04692020 Cart Part No B.584.4.10.023 , Kir 6Rta C R Brg0 75 04692020 Cart Part No B.584.4.10.033 , Hollow Dowel Cart Part No B2.005.16.0.00 , Thrust Ring Half(G.E.-Top) Cart Part No B2.005.18.0.00 , Thrust Ring Half(G.E.-Bottom) Cart Part No B2.005.19.0.00 , Oil Safeguard Switch Cart Part No Bp1.001.02.0.Pr , Crankcase Assembly Cart Part No Bp1.001.10.0.00 , Oil Level Switch Assembly Cart Part No Bp1.001.20.0.00 , Crankcase Cover Gasket Cart Part No Bp1.002.02.0.00 , Intake Valve Guide Seal Cart Part No Bp1.003.02.0.00 , Cylinder Head Gasket Cart Part No Bp1.003.05.0.00 , Cylinder Head Assembly Cart Part No Bp1.003.10.0.00 , Cylinder Cover Gasket Cart Part No Bp1.003.13.0.00 , Spark Plug Cart Part No Bp1.003.17.0.00 , Spark Plug Cart Part No Bp1.003.18.0.00 , Cylinder Head Assembly Cart Part No Bp1.003.20.0.00 , Flywheel Assembly Cart Part No Bp1.004.10.0.Pr , Piston Assembly Cart Part No Bp1.005.10.0.00 , Piston Ring Set Cart Part No Bp1.005.20.0.00 , Con Rod Assly Cart Part No Bp1.005.30.0.00 , Crankshaft Assembly Cart Part No Bp1.005.40.0.00 , Starter Motor Cart Part No Bp1.006.10.0.00 , Pusher Cart Part No Bp1.007.09.0.00 , Intake Valve Cart Part No Bp1.007.15.0.00 , Exhaust Valve Cart Part No Bp1.007.16.0.00 , Valve Spring Cart Part No Bp1.007.18.0.00 , Valve Collet Cart Part No Bp1.007.24.0.00 , Filter Element Cart Part No Bp1.008.03.0.00 , Air Cleanergasket Cart Part No Bp1.008.08.0.Pr , Air Cleaner Assembly Cart Part No Bp1.008.10.0.00 , Carburetor Assembly Cart Part No Bp1.010.10.0.00 , Carburettor Connecting Block Cart Part No Bp1.010.22.0.00 , Carburettor Metal Gasket Cart Part No Bp1.010.23.0.00 , Carburettor Front Gasket Cart Part No Bp1.010.24.0.00 , Carburettor Metal Gasket Cart Part No Bp1.010.25.0.00 , Carburettor Connecting Block Gasket Cart Part No Bp1.010.26.0.00 , Muffler Cart Part No Bp1.011.01.0.Pr , Exhaust Gasket Cart Part No Bp1.011.08.0.00 , Catcon And Catcon Pipe Assembly Cart Part No Bp1.011.10.0.Spr , Recoil Starter Assembly Cart Part No Bp1.020.10.0.00 , Fuel Pipe Tank To Cock 160 Mm Cart Part No Bp1.022.02.0.00 , Fuel Pipe Cock To Filter 35 Mm Cart Part No Bp1.022.03.0.00 , Fuel Pipe Filter To Carburetor Cart Part No Bp1.022.04.0.00 , Fuel Pipe Clip Cart Part No Bp1.022.14.0.00 , Fuel Tank & Strainer Assly Cart Part No Bp1.022.30.0.00 , Mcb 13 Amp Cart Part No Bp1.023.41.0.00 , Speed Regulating Assembly Cart Part No Bp1.026.10.0.00 , Lub Oil Drain Pipe Assembly Cart Part No Bp1.026.11.0.00 , Spark Plug Cap Cart Part No Bp1.027.02.0.00 , Charge Coil Cart Part No Bp1.027.07.0.00 , Ignition Coil Assembly Cart Part No Bp1.027.10.0.00 , Charge Coil Assembly Cart Part No Bp1.027.20.0.00 , Wet Pm Kit (W/O Oil) For Bp1.3001 - Ccp302 Cart Part No Bp1.999.87.0.Sp , Bearing C Bush Kir Sl90 Cart Part No C.055.5.00.703 , C.073.6.00.003 Bearing C/Bush Kir Ha 394 Cart Part No C.073.6.00.003 , C.073.6.00.703 Bearing C/Bush Kir Ha 394 Cart Part No C.073.6.00.703 , Bearing Cam Bush Kir Dv10std Pf Cart Part No C.547.5.00.003 , Bearing C/Bush: Rb33 Std Pf Cart Part No C.597.6.00.003 , Cylinder Head Nut (Long) Cart Part No Cc1.001.003.0.00 , Cylinder Head Nut (Short) Cart Part No Cc1.001.004.0.00 , Rectangle Ring Gasket (4.1 X 4.25 X 2.3) Cart Part No Cc1.001.007.0.00 , Oil Seal: Rear 35X50x8 Cart Part No Cc1.001.011.0.00 , Oil Pressure Switch Cart Part No Cc1.001.012.0.00 , Oil Dipstickwith O Ring Cart Part No Cc1.001.018.0.00 , Sealing Plate Gasket Cart Part No Cc1.001.020.0.00 , Sealing Plate Cart Part No Cc1.001.021.0.00 , Thrust Piece And Locking Plate Cart Part No Cc1.001.022.0.00 , Needle Bearing 7941/15 Cart Part No Cc1.001.024.0.00 , Ball Bearing Cart Part No Cc1.001.025.0.00 , Crankcase Cover Gasket Cart Part No Cc1.001.026.0.00 , Bearing 6207 Cart Part No Cc1.001.027.0.00 , Oil Seal: Front 35X50x10 Cart Part No Cc1.001.033.0.00 , Drain Bolt Entension With Washer Cart Part No Cc1.001.036.0.00 , Start Switch Assembly Cart Part No Cc1.001.043.0.00 , Cylinder Head Stud (Long) M10x118 Cart Part No Cc1.001.052.0.00 , Cylinder Head Stud (Short) M10x105 Cart Part No Cc1.001.053.0.00 , Oil Drain Plug M16x15 With Gasket Cart Part No Cc1.001.054.0.00 , Cylinder Head Gasket 0.1 Cart Part No Cc1.001.061.0.00 , Cylinder Head Gasket 0.2 Cart Part No Cc1.001.062.0.00 , Cylinder Head Gasket 0.3 Cart Part No Cc1.001.063.0.00 , Cylinder Head Gasket 0.4 Cart Part No Cc1.001.064.0.00 , Cylinder Head Gasket 0.5 Cart Part No Cc1.001.065.0.00 , Cylinder Head Gasket 0.6Mm Cart Part No Cc1.001.067.0.00 , Cylinder Block Cart Part No Cc1.001.10.0.00 , Crankcase Cover Assembly Cart Part No Cc1.001.40.0.00 , Cylinder Head Assembly Cart Part No Cc1.001.50.0.00 , Gasket: Rocker Cover Cart Part No Cc1.002.008.0.00 , Rocker Arm Intake Cart Part No Cc1.002.009.0.00 , Adjusting Valve Spacer Cart Part No Cc1.002.011.0.00 , Valve Collet Cart Part No Cc1.002.012.0.00 , Valve Spring Seat Cart Part No Cc1.002.013.0.00 , Valve Spring Cart Part No Cc1.002.014.0.00 , Valve Guide Oil Seal Cart Part No Cc1.002.015.0.00 , Valve Spring Washer Cart Part No Cc1.002.016.0.00 , Intake Valve Cart Part No Cc1.002.021.0.00 , Exhaust Valve Cart Part No Cc1.002.022.0.00 , Rocker Cover Gasket Cart Part No Cc1.002.042.0.00 , Rocker Cover Assembly Cart Part No Cc1.002.10.0.00 , Rocker Arm Assembly Cart Part No Cc1.002.20.0.00 , Cylinder Head Assembly Cart Part No Cc1.002.30.0.00 , Bearing 6203 Cart Part No Cc1.003.007.0.00 , Nut: Flywheel Cart Part No Cc1.003.020.0.00 , Flywheel Gear Ring: Elect Starter Cart Part No Cc1.003.021.0.00 , Sleeve For Fuel Pump Cart Part No Cc1.003.022.0.00 , Push Rod Cart Part No Cc1.003.023.0.00 , Tappet Cart Part No Cc1.003.024.0.00 , Camshaft Cart Part No Cc1.003.026.0.00 , Con Rod Bearing Cart Part No Cc1.003.029.0.00 , Con Rod Assly Cart Part No Cc1.003.040.0.00 , Piston Assembly Cart Part No Cc1.003.10.0.00 , Balancing Shaft Assly Cart Part No Cc1.003.40.0.00 , Flywheelalternator Rotor Cart Part No Cc1.003.42.0.00 , Flywheelalternator Stator Coil Cart Part No Cc1.003.43.0.00 , Flywheelalternator Screw M6 Cart Part No Cc1.003.44.0.00 , Crankshaft And Gear Assly Cart Part No Cc1.003.50.0.00 , Flywheel Assembly Cart Part No Cc1.003.60.0.00 , Camshaft Assly Cart Part No Cc1.003.70.0.00 , Fuel Controller Cart Part No Cc1.004.023.0.00 , Oil Pump Driving Gear Assembly Cart Part No Cc1.004.10.0.00 , Fork Lever Assembly Cart Part No Cc1.004.20.0.00 , Speed Control Handle Assembly Cart Part No Cc1.004.30.0.00 , Lub Oil Pump Assembly Cart Part No Cc1.004.40.0.00 , Oil Filter Cart Part No Cc1.004.50.0.00 , Speed Control Handle Assembly Cart Part No Cc1.004.70.0.00 , Wind Leading Case Assembly Cart Part No Cc1.005.10.0.00 , Flange Bolt M8x1 25X25 8 8 Cart Part No Cc1.005.28.0.00 , Flange Bolt M8x1 25X15 8 8 Cart Part No Cc1.005.29.0.00 , Flange Bolt M8x1.25X20-8.8 Cart Part No Cc1.005.32.0.00 , Flange Bolt - M5x0.8X15 - 8.8 Cart Part No Cc1.005.37.0.00 , Air Cleaner Gasket Cart Part No Cc1.006.003.0.00 , Air Filter Element Cart Part No Cc1.006.008.0.00 , Extension Pipe Cart Part No Cc1.006.013.0.00 , Air Filter Hose Pipe Cart Part No Cc1.006.014.0.00 , Inlet Manifold Gasket Cart Part No Cc1.006.026.0.00 , Inlet Manifold Cart Part No Cc1.006.027.0.00 , Inlet Manifoldflame Heater Arrangement Cart Part No Cc1.006.035.0.Pr , Air Filter Hose Pipe Cart Part No Cc1.006.039.0.00 , Air Cleaner Assembly Cart Part No Cc1.006.110.0.00 , Air Inlet Manifold With Bush Cart Part No Cc1.006.28.0.Pr , Gasket Cart Part No Cc1.006.32.0.Pr , Gasket Cart Part No Cc1.006.36.0.Pr , Cold Starting Kit For Kcc Genset Minus 10 Degree Cart Part No Cc1.006.80.0.00 , Cold Starting Electrical Kit For Kcc Genset Minus 10 Degree Cart Part No Cc1.006.90.0.Pr , Fuel Filterwire Mesh Type Cart Part No Cc1.008.001.0.00 , Rotor Rear Fan Bush Cart Part No Cc1.009.25.0.Pr , Fuel Tank Cap Cart Part No Cc1.010.002.0.00 , Fuel Gauge Cart Part No Cc1.010.005.0.00 , Fuel Filter Cart Part No Cc1.010.007.0.00 , Flange Bolt M6x1x25 8.8 Cart Part No Cc1.010.008.0.00 , Hose Clip N16 Cart Part No Cc1.010.014.0.00 , Hose Clip Cart Part No Cc1.010.015.0.00 , Rubber Ring Gasket Cart Part No Cc1.010.016.0.00 , Rubber Window Cart Part No Cc1.010.017.0.00 , Fuel Pipe Id 7, Od 15, L 50 Mm Cart Part No Cc1.010.021.0.00 , Fuel Pipe Id 7, Od 15,L 130 Mm Cart Part No Cc1.010.022.0.00 , T-Joint Cart Part No Cc1.010.023.0.00 , Fuel Pipe Id 5, Od 10,L 175 Mm Cart Part No Cc1.010.031.0.00 , Fuel Pipe Id 7, Od 15, L 400 Mm Cart Part No Cc1.010.032.0.00 , Fuel Pipe From Filter To Engine Cart Part No Cc1.010.055.0.Pr , Fuel Pipe From Tank To Filter Cart Part No Cc1.010.056.0.Pr , Fuel Pipe From Filter To T Joint Cart Part No Cc1.010.057.0.Pr , Fuel Pipe From T Joint To Engine Cart Part No Cc1.010.058.0.Pr , Air Vent Pipe From T Joint To Fuel Tank Cart Part No Cc1.010.059.0.Pr , T Joint Cart Part No Cc1.010.060.0.Pr , Fuel Tank Sub Assembly With Cap Cart Part No Cc1.010.20.0.00 , Special Banjo Bolt Cart Part No Cc1.010.72.0.Pr , Fuel Tank With Strainer Cart Part No Cc1.010.80.0.00 , Rubber Ring Gasket Cart Part No Cc1.010.97.0.00 , Anti Vibration Mountpmount P 1B Whitep 503 Cart Part No Cc1.013.06.0.Pr , Fixed Wheel Assly Cart Part No Cc1.013.10.0.00 , Castor Wheel Assly Cart Part No Cc1.013.20.0.00 , Anti Vibration Mounts: Cchilii Cpcbii Cart Part No Cc1.013.40.0.00 , Tpr Fixed Wheel 100 Cart Part No Cc1.013.81.0.Pr , Tpr Swivel Wheel 100 Cart Part No Cc1.013.82.0.Pr , P-Mount Pd-1B (White) Cart Part No Cc1.013.83.0.Pr , Rubber 808A Blue Avm For Portable Cart Part No Cc1.013.87.0.Pr , Fip Adjusting Gasket: 0.5 Cart Part No Cc1.014.009.0.00 , Sealing Plate Gasket Cart Part No Cc1.014.011.0.00 , High Pressure Pipe Cart Part No Cc1.014.012.0.00 , Solenoid Base Cart Part No Cc1.014.014.0.00 , Solenoid Coil Cart Part No Cc1.014.016.0.00 , Fuel Injector Stud M6x1x50 Cart Part No Cc1.014.019.0.00 , Fuel Inj Pump Assly Cart Part No Cc1.014.021.0.00 , Fuel Inj Pump Assly Cart Part No Cc1.014.022.0.00 , Fuel Injectoradjusting Gasket Cart Part No Cc1.014.023.0.00 , Fuel Injection Pump Adjusting Gasket (0.1) Cart Part No Cc1.014.024.0.00 , Solenoid Assly Cart Part No Cc1.014.40.0.00 , Fuel Injection Pump Assembly Cart Part No Cc1.014.60.0.00 , Fuel Piping Assembly Cart Part No Cc1.015.10.0.00 , Catcon Box With Foam Cart Part No Cc1.016.012.0.00 , Catcon Box With Foam Cart Part No Cc1.016.013.0.00 , Engine Top Cowl Cart Part No Cc1.016.016.0.00 , Engine Bottom Cowl Cart Part No Cc1.016.017.0.00 , Key Type Lock: Small Cart Part No Cc1.016.034.0.00 , Snap Type Lock-Polymide Slide Latch Cart Part No Cc1.016.036.0.00 , Rubber Beading (Shock Pad) Cart Part No Cc1.018.001.0.00 , Cowling Assembly Cart Part No Cc1.018.20.0.00 , 32Amp Plug 2P + E Cart Part No Cc1.020.001.0.00 , Fuel Tank Cap For Kcc Portable Genset Cart Part No Cc1.020.96.0.00 , Fuel Level Sensor Hight132mm Cart Part No Cc1.022.03.0.Pr , Adaptor For Lop Sendor & Switch Cart Part No Cc1.032.03.0.00 , Electric Fuel Pump Cart Part No Cc1.073.03.0.Pr , Head Gasket 0 1 Mm Cart Part No Cc1.099.006.0.00 , Head Gasket 0 2 Mm Cart Part No Cc1.099.007.0.00 , Charging Magneto Cart Part No Cc1.099.011.0.00 , Inlet Gasket Air Filter Cart Part No Cc1.099.013.0.00 , Push Rod Cart Part No Cc1.099.019.0.00 , Inlet Valve Assly Cart Part No Cc1.099.021.0.00 , Exhaust Valve Cart Part No Cc1.099.022.0.00 , Subassembly Of Cc418 Diesel Engine Cart Part No Cc1.1013.10.0.00 , Flame Heater Cart Part No Cc1.108.01.0.Pr , 0-300 Vac Analogue Voltmeter Cart Part No Cc1.120.002.0.00 , 32Amp Socket: 2P+E Cart Part No Cc1.120.05.0.00 , Hour Meter 230V Ac: Cchili Cart Part No Cc1.120.09.0.00 , Mcb: 17.5A 1 Pole Power On/Off Cart Part No Cc1.120.29.0.00 , 6A 12V Dc Battery Charger Cart Part No Cc1.120.33.0.Pr , Battery Charger : 5A 12 Vdc Cart Part No Cc1.120.48.0.00 , Load On Lamp Cart Part No Cc1.120.52.0.00 , 5 Pin Male Connector Cart Part No Cc1.120.56.0.00 , 5 Pin Female Connector Cart Part No Cc1.120.57.0.00 , Key Lock Switch 3A Cart Part No Cc1.120.61.0.00 , Avr Cchilli Alterernator 5Kva Cart Part No Cc1.121.004.0.00 , 5Kva Alternator Rotor Cart Part No Cc1.121.11.0.00 , Alternator Rear Frame For Chhota Chilli Cart Part No Cc1.121.15.0.00 , Alternator Fan: Chota Chili Cart Part No Cc1.121.17.0.00 , Bearing 6204 Cart Part No Cc1.121.29.0.00 , Rotor Set Bolt M10x1.25X260 Cart Part No Cc1.121.38.0.00 , Alternator Front Frame Cart Part No Cc1.121.42.0.00 , 5Kva Alternator Carbon Bush Cart Part No Cc1.121.44.0.00 , Rotor Rear Fan Cart Part No Cc1.121.53.0.00 , Avrmodel Av 132 S Cart Part No Cc1.121.64.0.Pr , Avrmodel Ds Cart Part No Cc1.121.67.0.Pr , Fan Bush Assy Cart Part No Cc1.121.73.0.Pr , 16 Amp Socket 2P + E Cart Part No Cc1.122.05.0.00 , 16 Amp Plug Cart Part No Cc1.122.06.0.00 , 6A/10A Toggle Switch For Dc Supply On/ Off Cart Part No Cc1.130.05.0.00 , 5Kva Kcc Amf Panel Assembly Cart Part No Cc1.130.30.0.00 , 5.5 Kva Kcc Amf Panel Assembly Cart Part No Cc1.140.50.0.Pr , 12V2a Battery Charger With Input Output Leads Cart Part No Cc1.150.53.0.Pr , Gasket Muffler Engine Side Cart Part No Cc1.151.023.0.00 , Exhaust System For Cc 418 Engine Cart Part No Cc1.151.06.0.Spr , Catalytic Converter (Catcon) Cart Part No Cc1.151.101.0.Pr , Muffler Assy Cart Part No Cc1.151.103.0.Pr , Exhaust Silencer For Chotta Chilli Cart Part No Cc1.151.11.0.Pr , Exhaust Gasket Cart Part No Cc1.151.13.0.00 , Exhaust Gasketengine Side Cart Part No Cc1.151.16.0.00 , Expansion Bellow Cart Part No Cc1.151.21.0.00 , Exhaust Gasket Cart Part No Cc1.151.23.0.00 , Exhaust Silencerupperfor Chotta Chilli Cart Part No Cc1.151.66.0.Pr , Lower Silencer Assly Cart Part No Cc1.151.75.0.Pr , Upper Silencer Assly Cart Part No Cc1.151.76.0.Pr , Gasketgraphite Cart Part No Cc1.151.99.0.Pr , 5Kva Brushless Alternator S F Cc418 Engine Cart Part No Cc1.153.03.0.Pr , Alternator Assly Cart Part No Cc1.153.10.0.00 , Alternator For Rotor Assembly For Chhota Chilli Cart Part No Cc1.153.20.0.00 , 5Kva Alternator Stator Assembly Cart Part No Cc1.153.30.0.00 , Rectifier +(Suitable For Alternator : Cc1.153.03.0.Pr) Cart Part No Cc1.153.33.0.00 , Rectifier -(Suitable For Alternator : Cc1.153.03.0.Pr) Cart Part No Cc1.153.34.0.00 , Mov(Suitable For Alternator : Cc1.153.03.0.Pr) Cart Part No Cc1.153.36.0.00 , Connector Plate Assembly Cart Part No Cc1.153.40.0.00 , Alternator Assembly Cart Part No Cc1.156.20.0.00 , Engine Wiring Harness For Chhota Chilli Cart Part No Cc1.160.30.0.00 , Engine Wiring Harness For Chhota Chilli Cart Part No Cc1.160.80.0.Pr , Control Cable For Amf Ats Panel Kcc Cart Part No Cc1.170.20.0.00 , Canopy For 5Kva Chhota Chilli Diesel Fabrication Parts With Foam Locks Cart Part No Cc1.175.10.8.00 , 5 Kva Diesel Std Front Door Assly Cart Part No Cc1.175.32.0.00 , 5 Kva Diesel Std Noise Damper Assly Cart Part No Cc1.175.35.0.00 , 5 Kva Diesel Std Rh Panel Assy Cart Part No Cc1.175.36.0.00 , 5Kva Diesel Std Lh Panel Assly. Cart Part No Cc1.175.38.0.00 , Pm Alternator Module 6Kw Cart Part No Cc1.175.57.0.Pr , Dc Regulator With Bat Reverse Protection Cart Part No Cc1.175.63.0.Pr , Fuel Tank With Strainer Cart Part No Cc1.175.88.0.Pr , Fuel Hose Pipe From Filter To T Joint & Tank To Filter (Id- 7Mm Od-14Mm,L-55Mm) Cart Part No Cc1.175.93.0.Pr , Fuel Hose Pipe 3 Air Vent Pipe From T Joint To Fuel Tank (Id- 5Mm Od-13Mm,L-180Mm) Cart Part No Cc1.175.96.0.Pr , Fuel Hose Pipe 4 From T Joint To Engine (Id- 7Mm Od-14Mm,L-310) Cart Part No Cc1.175.97.0.Pr , Fuel Hose Pipe 5 (Id- 5Mm Od-13Mm,L-770Mm) Cart Part No Cc1.175.99.0.Pr , Battery Cable Assy For 5Kva Chhota Chilli Genset Cart Part No Cc1.180.20.0.Pr , Injector Copper Washer 8X15 (0.1Mm) Cart Part No Cc1.190.013.0.00 , Injector Copper Washer 8X15 (0.2Mm) Cart Part No Cc1.190.014.0.00 , Injector Copper Washer 8X15 (0.3Mm) Cart Part No Cc1.190.015.0.00 , Injector Copper Washer 8X15 (0.4Mm) Cart Part No Cc1.190.016.0.00 , Injector Copper Washer 8X15 (1 Mm) Cart Part No Cc1.190.017.0.00 , Injector Copper Washer 8X15 (1.5 Mm) Cart Part No Cc1.190.018.0.00 , Injector Copper Washer 8X15 (2 Mm) Cart Part No Cc1.190.019.0.00 , Injector Copper Washer 8X15 (3 Mm) Cart Part No Cc1.190.021.0.00 , Injector Cart Part No Cc1.190.06.0.00 , Fuel Overflow Connection For Injector Cart Part No Cc1.190.25.0.00 , Fuel Injector Assembly Cart Part No Cc1.190.30.0.00 , Piston Assembly Cart Part No Cc1.191.12.0.Pr , Piston Ring Set Cart Part No Cc1.191.30.0.00 , Starter 12V Cart Part No Cc1.193.01.0.00 , Pm Alternator Stator Cart Part No Cc1.193.012.0.00 , Pm Alternator Rotor Gear Ring Cart Part No Cc1.193.014.0.00 , Pm Alternator Rotor Cart Part No Cc1.193.015.0.00 , Pm Alternator Rotor Fan Cart Part No Cc1.193.018.0.00 , Adaptor: Chota Chilli Cart Part No Cc1.193.02.0.00 , Pm Alternator Assembly Cart Part No Cc1.193.40.0.00 , Recoil Starter Assembly Cart Part No Cc1.196.10.0.00 , Flange Bolt M6x1x30 Cart Part No Cc1.300.01.0.00 , Gas Spring 600N Cart Part No Cc1.300.24.0.00 , Spark Arrestor Cart Part No Cc1.405.01.0.Sp , Wet Pm Kit (W/O Oil) For Cc1.1051 - Cc418 Cart Part No Cc1.999.02.0.Sp , Wet Pm Kit (W/O Oil) For Cc1.3008... - Cc306 G1 Cart Part No Cc1.999.11.0.Sp , Wet Pm Kit (W/O Oil) For 5Kva_Cc1.4007 - Cc418 G1.1 Cart Part No Cc1.999.17.0.Sp , Wet Pm Kit (W/O Oil) For Cc1.4001.96 ,Cc1.4004.96, Cc1.4004- Chhota Chilli5kva Portabl Cart Part No Cc1.999.55.0.Sp , Rear Oil Seal Cart Part No Cc3.001.006.0.00 , Ball Bearing Cart Part No Cc3.001.010.0.00 , Cylinder Head Stud (Short) Cart Part No Cc3.001.011.0.00 , Rectangle Ring Gasket 4.5X2.2 Cart Part No Cc3.001.017.0.00 , Crankcasecover Gasket Cart Part No Cc3.001.025.0.00 , Ball Bearing Cart Part No Cc3.001.026.0.00 , Front Oil Seal Cart Part No Cc3.001.032.0.00 , Cylinder Head Gasket0.5 Mm Cart Part No Cc3.001.76.0.00 , Intake Valve Cart Part No Cc3.002.003.0.00 , Exhaust Valve Cart Part No Cc3.002.004.0.00 , Rocker Arm Cart Part No Cc3.002.017.0.00 , Adjusting Valve Spacer Cart Part No Cc3.002.018.0.00 , Valve Collet Cart Part No Cc3.002.019.0.00 , Valve Spring Seat Cart Part No Cc3.002.020.0.00 , Valve Guide Oil Seal Cart Part No Cc3.002.022.0.00 , Rocker Arm Assembly Cart Part No Cc3.002.20.0.00 , Cylinder Head Assembly Cart Part No Cc3.002.30.0.00 , Rockercover Gasket Cart Part No Cc3.003.001.0.00 , Con Rod Assly Cart Part No Cc3.003.040.0.00 , Lub Oil Pump Assembly Cart Part No Cc3.004.10.0.00 , Oil Pump Driving Gear Assembly Cart Part No Cc3.004.20.0.00 , Fork Lever Assembly Cart Part No Cc3.004.30.0.00 , Connecting Rod Bearing Cart Part No Cc3.005.009.0.00 , Piston Assembly Cart Part No Cc3.005.10.0.00 , Piston Ring Set Cart Part No Cc3.005.30.0.00 , Ball Bearing Cart Part No Cc3.006.009.0.00 , Flywheel Gear Ring Cart Part No Cc3.006.011.0.00 , Balancing Shaft Assly Cart Part No Cc3.006.10.0.00 , Inlet Manifold Gasket Cart Part No Cc3.006.21.0.00 , Push Rod Cart Part No Cc3.007.001.0.00 , Tappet Cart Part No Cc3.007.002.0.00 , Cam Shaft & Gear Assembly Cart Part No Cc3.007.10.0.00 , Crankshaft And Gear Assly Cart Part No Cc3.007.20.0.00 , Air Filter Hose Pipe Cart Part No Cc3.008.001.0.00 , Air Cleaner Gasket Cart Part No Cc3.008.004.0.00 , Air Filter Element Cart Part No Cc3.008.008.0.00 , Extension Pipe Cart Part No Cc3.008.015.0.00 , Oil Seal Cart Part No Cc3.012.014.0.00 , Fuel Controller Cart Part No Cc3.012.015.0.00 , Anti Vibration Mountpmount P 1A Bluep 503 Cart Part No Cc3.013.08.0.Pr , Recoil Starter Assmbly Cart Part No Cc3.015.20.0.00 , Engine Speed Control Assembly Cart Part No Cc3.017.20.0.00 , Crankcase Cover Gasket Cart Part No Cp1.002.02.0.00 , Crankcase Cover Assembly Cart Part No Cp1.002.10.0.00 , Cylinder Head Gasket Cart Part No Cp1.003.05.0.00 , Cylinder Head Assembly Cart Part No Cp1.003.10.0.00 , Cylinder Cover Gasket Cart Part No Cp1.003.13.0.00 , Flywheel Assembly Cart Part No Cp1.004.10.0.00 , Piston Assly Cart Part No Cp1.005.10.0.00 , Piston Ring Set: Std Cart Part No Cp1.005.20.0.00 , Connecting Rod Assy Cart Part No Cp1.005.30.0.00 , Crankshaft Assembly Cart Part No Cp1.005.40.0.00 , Starter Motor Cart Part No Cp1.006.10.0.00 , Pusher Cart Part No Cp1.007.09.0.00 , Intake Valve Cart Part No Cp1.007.15.0.00 , Exhaust Valve Cart Part No Cp1.007.16.0.00 , Rocker Arm Assembly Cart Part No Cp1.007.20.0.00 , Carburetor Assembly Cart Part No Cp1.010.10.0.00 , Carburettor Rear Gasket Cart Part No Cp1.010.23.0.00 , Carburettor Front Gasket Cart Part No Cp1.010.24.0.00 , Carburettor Metal Gasket Cart Part No Cp1.010.25.0.00 , Catcon And Catcon Pipe Assembly Cart Part No Cp1.011.20.0.Spr , Anti Vibration Mount (708A Mix 03 Blue40 4 To 5 Alternetor Side ) Cart Part No Cp1.012.01.0.Pr , Recoil Starter Assembly Cart Part No Cp1.020.10.0.00 , Ignition Coil Assembly Cart Part No Cp1.027.10.0.00 , Complete Engine Assembly Ccp389 Cart Part No Cp1.1001.100.0.00 , Small End Bush-Dm10. Cart Part No D1.005.03.0.00 , Joint Ring: Liner Dm10 Cart Part No D1.008.02.0.00 , Crankshaft Assly: Dm10 Cart Part No D1.011.40.0.00 , Fuel Pump Cart Part No D1.019.10.0.00 , Con.Rod Assly-Dm10(70 Mm Pin ) Cart Part No D1.035.10.0.00 , Fuel Pump Bracket Cart Part No D1.131.01.0.00 , Fuel Pump Tappet Plunger:Ew10 Cart Part No D1.131.02.0.00 , F.P.Rocker Lever Cart Part No D1.131.03.0.00 , Roller Cart Part No D1.131.04.0.00 , Roller Pin Cart Part No D1.131.05.0.00 , Assembly Of Fpr Lever - Ew10 Cart Part No D1.131.10.0.00 , Joint: Rocker Cover Cart Part No D1.133.09.0.00 , Piston Assembly Cart Part No D1.134.20.0.00 , Piston Ring Set - Ew10,3 Rv Cart Part No D1.134.30.0.00 , Piston Ring Set-Ea10 102.12 Cart Part No D1.134.40.0.00 , Piston Assembly: Ea10 With Ring Set 102.12 Cart Part No D1.134.50.0.00 , Gasket: Cylinder Head Ew10 Cart Part No D1.135.02.0.00 , Valve Guide(Semi-Finish) - Ew10 Cart Part No D1.135.03.9.00 , Cylinder Head Gasketnamew10 Cart Part No D1.135.18.0.00 , Valve Push Rod Cart Part No D1.138.01.0.00 , Air Inlet Manifold Cart Part No D1.139.01.0.00 , Joint: Air Inlet Mfold-Ew10 Cart Part No D1.139.03.0.00 , Gasket: Exhaust Ew10 Cart Part No D1.140.03.0.00 , Fulcrum Bracket Assly: Ew10 Cart Part No D1.148.20.0.00 , Fulcrum Bracket Assemblywith Indicator E Series Acwr Engines Cart Part No D1.148.30.0.00 , Cyl Liner Assembly-Ew10 Cart Part No D1.311.10.0.00 , Anti Vibration Mounts Cart Part No D1.314.01.0.00 , Anti Vibration Mounts Cart Part No D1.314.02.0.00 , Bush For Avm Locking S F 90 Crs Avms Cart Part No D1.316.05.0.00 , Set Of Joints Cart Part No D1.317.40.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No D1.326.01.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No D1.326.02.0.00 , Gear Pump Assembly With Relief Valve Cart Part No D1.328.10.0.00 , Mb Hsg + Brg Assembly Ge - Ew10 Cart Part No D1.329.10.0.00 , Wet Pm Kit (W/O Oil) For D1.4805.91 - Ew10 Cart Part No D1.999.04.0.Sp , M Bcap Side Boltm12x1 75X145 L Cart Part No D16.001.09.0.00 , M Bcap Side Boltm12x1 75X165 L Cart Part No D16.001.11.0.00 , M Bcap Side Boltm12x1 75X188 L Cart Part No D16.001.12.0.00 , Joint For Core Window120 Crs6 Holes Cart Part No D16.001.31.0.Pr , Joint For Core Window100 Crs6 Holes Cart Part No D16.001.32.0.Pr , Ferrul Tube For Push Rod Cart Part No D16.001.36.0.Pr , Nozzle Body Cart Part No D16.001.39.0.Pr , Sealing Ring (For Push Rod) Cart Part No D16.001.48.0.00 , Spacerfor Hp Pipe Cart Part No D16.001.56.0.Pr , Oil Spray Nozzle Cart Part No D16.001.58.0.Pr , Balance Weight For All Webs Cart Part No D16.003.03.0.Pr , Adaptor For Crank Pulley Cart Part No D16.003.06.0.00 , Crankshaft Gear115 Length Cart Part No D16.003.14.0.Pr , Crank Pulley (Pcd 232) Poly V 12Pk Cart Part No D16.003.15.0.Pr , Crank Shaft Assly Cart Part No D16.003.20.0.Pr , Thrust Plate For Cam Shaft Cart Part No D16.004.03.0.00 , Camgear Speed Ring Cart Part No D16.004.04.0.00 , Thrust Plate For Cam Shaftwidth 17 9 Cart Part No D16.004.05.0.Pr , Thrust Plate For Cam Shaftwidth 18 7 Cart Part No D16.004.11.0.00 , Thrust Platefor Cam Shaftwidth 17 5 Cart Part No D16.004.13.0.00 , Thrust Plate Cart Part No D16.004.15.0.00 , Thrust Plate Width 18 2 Cart Part No D16.004.16.0.00 , Cam Gearfinish Cart Part No D16.004.17.0.Pr , Pistonfor 1250Kva Cart Part No D16.006.07.0.Pr , Cylinder Head Assembly Complete Cart Part No D16.007.150.0.Pr , Double Gear Support Cart Part No D16.011.11.0.Pr , Joint (For Oil Seal Housing) Cart Part No D16.012.02.0.00 , Pumping Geardriving Cart Part No D16.013.03.0.00 , Pumping Geardriven Cart Part No D16.013.04.0.00 , Oil Pump Housing Shim 0 2 Thick Cart Part No D16.013.16.0.Pr , Lub Oil Pump Sub Assly 100Mm Wide Cart Part No D16.013.30.0.Pr , Lub Oil Cooler Header (L.H.) Cart Part No D16.014.01.0.Pr , Lub Oil Cooler Header (R.H.) Cart Part No D16.014.02.0.Pr , Fuelpipe(Fuelpumptomainfilter)(Lhfromge) Cart Part No D16.014.05.0.00 , Oil Filter Adaptor Cart Part No D16.014.09.0.Pr , Lub Oil Cooler Headear Assly(Rhs) Cart Part No D16.014.10.0.Pr , Oil Cooler Cart Part No D16.014.12.0.Pr , Relief Valve Body Cart Part No D16.014.13.0.00 , Joint For Lub Oil Headerrh Cart Part No D16.014.15.0.Pr , Threaded Plug For Relief Valve Body Cart Part No D16.014.16.0.Pr , Header Mounting Boltm10x1 5X135l Cart Part No D16.014.17.0.Pr , Adaptor (Male M22x1.5 & Female M10x1) Cart Part No D16.014.18.0.Pr , Lub Oil Cooler Headear Assly(Lhs) Cart Part No D16.014.20.0.Pr , O Ring (For Relief Valve Body ) Cart Part No D16.014.21.0.Pr , Jointfor Oil Filter Adaptor Cart Part No D16.014.22.0.Pr , Lub Oil Cooler Header & Oil Filter Adaptor Assembly Lh Cart Part No D16.014.40.0.Pr , O Ring For W.P. Housing Cart Part No D16.016.03.0.00 , Jointbetween Water Pump Thermostat Cover Cart Part No D16.016.04.0.Pr , Water Pump Assembly Cart Part No D16.016.100.0.Pr , Water Pump Pulleypcd 115 Poly V 12 Pk Cart Part No D16.016.15.0.Pr , Suction Tubewith Flanged Ends R H Cart Part No D16.016.16.0.00 , Suction Tubewith Flanged Ends Cart Part No D16.016.17.0.Pr , 12 Pk Poly V Belt 2630 Epdm Cart Part No D16.016.22.0.Pr , Jointforplate W P Housing Rh Cart Part No D16.016.26.0.Pr , Jointforplate Water Pump Housing Lh Cart Part No D16.016.29.0.Pr , V Belt For 1800Rpm Cart Part No D16.016.37.0.Pr , Dipstick Assemblyfor 1250Kva Cart Part No D16.017.130.0.Pr , Lub Oil Sumpfabricated Cart Part No D16.017.14.0.Pr , Adaptor For Dipstick Cart Part No D16.017.17.0.00 , Joint ( For Oil Filling Body) Cart Part No D16.017.18.0.00 , Dipstick Assemblydipstick With Adaptor Cart Part No D16.017.50.0.Pr , Bracket For Fuel Filter Cart Part No D16.020.02.0.00 , Hp Pipe Assembly (Rail To Cylinder No. 1 & 5) Cart Part No D16.021.110.0.Pr , Hp Pipe Assembly (Rail To Cylinder No. 2 & 6) Cart Part No D16.021.120.0.Pr , Hp Pipe Assembly (Rail To Cylinder No. 3 & 7) Cart Part No D16.021.130.0.Pr , Hp Pipe Assembly (Rail To Cylinder No. 4 & 8) Cart Part No D16.021.140.0.Pr , Hp Pipe Assemblyrail To Cylinder No9 13 Cart Part No D16.021.150.0.00 , Hp Pipe Assemblyrail To Cylinder No9 13 Cart Part No D16.021.150.0.Pr , Hp Pipe Assemblyrail To Cylinder No10 14 Cart Part No D16.021.160.0.Pr , Hp Pipe Assemblyrail To Cylinder No11 15 Cart Part No D16.021.170.0.00 , Hp Pipe Assemblyrail To Cylinder No11 15 Cart Part No D16.021.170.0.Pr , Hp Pipe Assemblyrail To Cylinder No12 16 Cart Part No D16.021.180.0.Pr , Hp Pipe Assembly (Rail Connection) Cart Part No D16.021.190.0.Pr , Hp Pipe Assemblypump To Rail Lhs Cart Part No D16.021.210.0.Pr , Hp Pipe Assembly (Pump To Rail Rhs) Cart Part No D16.021.220.0.Pr , Hp Pipe Assembly(Routed Rail To Cyl. 4) Cart Part No D16.021.230.0.Pr , Hp Piperail To Cylinder No1 16 Cart Part No D16.021.34.0.Pr , Hp Piperail To Cylinder No2 15 Cart Part No D16.021.36.0.Pr , Hp Piperail To Cylinder No3 14 Cart Part No D16.021.37.0.Pr , Hp Piperail To Cylinder No4 13 Cart Part No D16.021.38.0.Pr , Hp Pipe (Rail To Cylinder No. 5 & 12) Cart Part No D16.021.39.0.00 , Hp Pipe (Rail To Cylinder No. 6 & 11) Cart Part No D16.021.41.0.00 , Hp Pipe (Rail To Cylinder No. 8 & 9) Cart Part No D16.021.42.0.00 , Hp Piperail To Cylinder No7 10 Cart Part No D16.021.43.0.Pr , Hp Pipepump To Rail Lhs Cart Part No D16.021.44.0.Pr , Hp Pipepump To Rail Rhs Cart Part No D16.021.46.0.Pr , Hp Pipe (Balancing Pipe) Cart Part No D16.021.47.0.00 , Rail Connection Cart Part No D16.021.48.0.00 , Clamp For Hp Pipe (Pump To Rail) (Mntg. On Rail Clamp) Cart Part No D16.021.49.0.00 , Hp Pipefip To Rail Rh Side Cart Part No D16.021.55.0.Pr , Hp Pipefip To Rail Lh Side Cart Part No D16.021.56.0.Pr , Bracketfor Rail Mtglhs Cart Part No D16.021.63.0.Pr , Bracketfor Rail Mtgrhs Cart Part No D16.021.64.0.Pr , Bracketfor Hp Pipe Cart Part No D16.021.66.0.Pr , Rail Assembly 1Pulley End Cart Part No D16.021.91.0.Pr , Rail Assembly 2Flywheel End Cart Part No D16.021.92.0.Pr , Bracket For Hp Pipe Cart Part No D16.021.93.0.Pr , Fuel Pipe (Fuel Pump To Main Filter) (Lh From Ge) Cart Part No D16.022.102.0.00 , Fuel Pipefuel Pump To Main Filter Rh From Ge Cart Part No D16.022.103.0.Pr , Head Leak Off Pipe Assembly Cart Part No D16.022.107.0.Pr , Fuel Pipe(Pre Filter To Main Filter Common) Cart Part No D16.022.112.0.00 , Deairazation Pipe Cart Part No D16.022.114.0.00 , Adaptorm16 X M14 Cart Part No D16.022.12.0.Pr , Fuel Pipepump Leak Off L Hfrom G E Cart Part No D16.022.139.0.Pr , Fuel Pipe (Pump Leak Off Pipe R.H. From Ge) Cart Part No D16.022.141.0.00 , Fuel Pipe (Main Filter To Pump R.H. Side) Cart Part No D16.022.142.0.Pr , Fuel Pipe (Main Filter To Pump L.H. Side) Cart Part No D16.022.143.0.00 , Fuel Piperail Leackoff Pipe Assembly Cart Part No D16.022.147.0.Pr , Fuel Pipe Cart Part No D16.022.149.0.Pr , Fuel Pipe Cart Part No D16.022.153.0.Pr , Fuel Piperhs From Ge Cart Part No D16.022.156.0.Pr , Fuel Pipe Cart Part No D16.022.167.0.Pr , Fuel Pipe Cart Part No D16.022.168.0.Pr , Fuel Pipe Cart Part No D16.022.169.0.Pr , Fuel Pipe Cart Part No D16.022.171.0.Pr , Fuel Pipe Cart Part No D16.022.172.0.Pr , Fuel Pipe ( Pre Filter To Main Filter Common ) Cart Part No D16.022.178.0.Pr , Inlet Manifold L H Gear End Cart Part No D16.023.01.0.Pr , Inlet Manifold R H Gear End Cart Part No D16.023.03.0.00 , Sleeve For Inlet Manifolddia 94 Cart Part No D16.023.13.0.Pr , Joint For Cover Plate Cart Part No D16.023.15.0.00 , Banjo Bolt Cart Part No D16.023.18.0.Pr , O Ringfor Inlet Manifold Adaptor Sleeve Dia 104 Cart Part No D16.023.28.0.Pr , O Ringfor Inlet Manifold Sleeve Dia 94 Cart Part No D16.023.29.0.Pr , Joint Bet. Inlet Manifold & Cyl Head Cart Part No D16.023.31.0.00 , O Ring Cart Part No D16.023.35.0.00 , Adaptor For Inlet Manifold2 Port Cart Part No D16.023.39.0.Pr , Sleeve For Inlet Manifolddia 117 Cart Part No D16.023.43.0.00 , O Ring For Inlet Manifold Adaptor Sleeve (Dia 117) Cart Part No D16.023.44.0.00 , Joint For Inlet Manifold Cart Part No D16.023.46.0.Pr , Joint (For Inlet Manifold R.H.) Cart Part No D16.023.48.0.00 , Joint (For Inlet Manifold L.H.) Cart Part No D16.023.49.0.00 , Inlet Manifoldrh From Pe Cart Part No D16.023.52.0.Pr , Inlet Manifold Lh From Pe Cart Part No D16.023.54.0.00 , Adaptor Cart Part No D16.023.59.0.Pr , Adaptor Cart Part No D16.023.61.0.Pr , Gasket Cart Part No D16.023.62.0.Pr , Stud M10x1 5 Cart Part No D16.023.64.0.Pr , Bracket Cart Part No D16.023.65.0.Pr , Banjo Bolt Cart Part No D16.023.66.0.00 , Exhaust Manifold Cart Part No D16.024.12.0.00 , Exhaust Manifold (Rh, Lh 2 Port) Cart Part No D16.024.13.0.00 , Exhaust Manifold (2 Port) Cart Part No D16.024.14.0.00 , Bracket Turbo Adaptor Rhs From Fwe Cart Part No D16.024.32.0.Pr , Bracket For Turbo Adaptor Lhs From Fwe Cart Part No D16.024.33.0.Pr , Expansion Bellow 3 Mm Cart Part No D16.024.35.0.00 , Exhaust Manifold (Adaptor Side M10) Cart Part No D16.024.37.0.00 , Bracket For Turbo Adaptor4 Bolts Cart Part No D16.024.42.0.Pr , Bracket For Turbo Adaptor3 Bolts Cart Part No D16.024.43.0.Pr , Turbo Adaptorlh From Ge Cart Part No D16.024.44.0.Pr , Turbo Adaptorrh From Ge Cart Part No D16.024.45.0.Pr , Bracket 1L Hfrom Fwe Cart Part No D16.024.46.0.Pr , Bracket 2L Hfrom Fwe Cart Part No D16.024.47.0.Pr , Bracket 3R Hfrom Fwe Cart Part No D16.024.48.0.Pr , Bracket 4R Hfrom Fwe Cart Part No D16.024.49.0.Pr , Expansion Bellow (For Exh. Manifold) Cart Part No D16.024.51.0.Pr , Joint For Flywheel Housing Cart Part No D16.025.02.0.00 , Joint For Gear Casing Cart Part No D16.025.04.0.00 , Cover Plate Cart Part No D16.025.11.0.00 , O Ring (For Cover Plate) Cart Part No D16.025.12.0.00 , Gear Casing Cart Part No D16.025.21.0.Pr , Deflectorfor Flywheel End Cart Part No D16.025.24.0.Pr , Mud Slingerfor Flywheel End Cart Part No D16.025.25.0.Pr , Starter Ring Cart Part No D16.026.07.0.00 , Bolt For Flywheel200 Mmlength Cart Part No D16.026.09.0.Pr , Sensor Ring Cart Part No D16.026.13.0.Pr , Flywheel Assy With Toothed Sensor Ring Cart Part No D16.026.30.0.Pr , 24V 9Kw Starter L H Sfrom Flywheel End Sideprestolite Ms7 304K Cart Part No D16.027.14.0.Pr , Deep Groove Ball Bearing ( 35 X 62 X 14 )6007-2Rs1 Cart Part No D16.029.03.0.00 , Spacer Bet. Extension Pulley & Crank Pulley Cart Part No D16.029.09.0.00 , Bracket Cart Part No D16.029.12.0.Pr , Pulley For Fan Drive250 P C D Cart Part No D16.029.34.0.Pr , Fan Drive Sub Assembly Cart Part No D16.029.50.0.Pr , Damper Cart Part No D16.030.01.0.Pr , Pipe Thermostat To Radiator In Cart Part No D16.031.07.0.Pr , D16 031 17 0 Pr Clamping Bracket For Thermostat Pipe Cart Part No D16.031.17.0.Pr , Dv2 031 18 0 Pr Clamp Cart Part No D16.031.18.0.Pr , Cooling Fan For Radiator (62 , 11 Blades) Cart Part No D16.031.35.0.Pr , Radiator For Dv16 Genset Cart Part No D16.031.60.0.Pr , Recovery Bottel Bracket Lh Cart Part No D16.031.61.0.Pr , Turbocharger For Dv16 Enginehe600fga112n68tc B97q89qc26ab Cart Part No D16.032.26.0.00 , V Band For Turbine Out Exhaust Bendd16 Ctt Turbochargerid 127 Mm Cart Part No D16.032.32.0.Pr , Turbo Oil Inlet Pipe (Lh From Pe) Cart Part No D16.032.36.0.00 , Turbo Oil Inlet Piperh From Pe Cart Part No D16.032.37.0.00 , Turbo Oil Drain Pipe (Lh From Pe) Cart Part No D16.032.38.0.00 , Joint For Turbocharger Cart Part No D16.032.43.0.Pr , Jointfor Flange For T C Lub Oil Outlet Pipe Cart Part No D16.032.44.0.00 , Jointfor Flange For T C Lub Oil Outlet Pipe Cart Part No D16.032.44.0.Pr , Turbocharger Asslyr Hfrom Pe Cart Part No D16.032.45.0.00 , Turbo Lub Oil Inlet Pipelhs Cart Part No D16.032.51.0.Pr , Turbo Oil Drain Pipelhs From Fwe Cart Part No D16.032.52.0.Pr , Turbo Lub Oil Inlet Piperhs Cart Part No D16.032.53.0.Pr , Turbo Oil Drain Piperhs From Fwe Cart Part No D16.032.54.0.Pr , 439619022074 Turbocharger For Dv16 Engine_Rhs Cart Part No D16.032.58.0.Pr , 439619022073 Turbocharger For Dv16 Engine_Lhs Cart Part No D16.032.59.0.Pr , Exhaust Elbowlhs From Ge Cart Part No D16.032.62.0.Pr , Exhaust Elbowrhs From Ge Cart Part No D16.032.63.0.Pr , Spacer13x30 Cart Part No D16.032.65.0.Pr , Cac Yoke Pipe Cart Part No D16.033.13.0.00 , Cac Pipe 1 Straight Pipe Cart Part No D16.033.14.0.00 , Cac Pipe 2 Straight Pipe To Radiator In Pipe Cart Part No D16.033.15.0.Pr , Sleeve For Cac Pipe Dia 114 Cart Part No D16.033.17.0.Pr , Sleeve For Cac Pipe Dia 84) Cart Part No D16.033.18.0.Pr , Top Bracket For Cac Pipe Cart Part No D16.033.22.0.Pr , Rubber Sleeve Cart Part No D16.033.24.0.00 , Joint Cart Part No D16.033.28.0.00 , Joint Cart Part No D16.033.28.0.Pr , T Bolt V Band Clamps (108 Dia). Cart Part No D16.033.34.0.00 , O Ring For Cac Pipe Sleeve114 Dia Cart Part No D16.033.35.0.Pr , O Ringfor Cac Pipe Sleeve Dia 84 Cart Part No D16.033.36.0.Pr , Compressor Out Pipe O Ringdv16 Ctt Turbocharger Cart Part No D16.033.37.0.Pr , Compressor Out Pipedv16 Ctt Turbocharger Rhs From Pe Cart Part No D16.033.38.0.00 , Compressor Out Pipedv16 Ctt Turbocharger Lhs From Pe Cart Part No D16.033.39.0.Pr , V Band For Compressor Out Piped16 Ctt Turbochargerid 100 Mm Cart Part No D16.033.41.0.Pr , Cac Out Pipe 1(Radiator To Inlet Manifold) Cart Part No D16.033.44.0.00 , Cac Out Pipe 2(Radiator To Inlet Manifold) Cart Part No D16.033.46.0.00 , Hose For Cac Pipeid 138 X Id 144 Cart Part No D16.033.47.0.Pr , Hose For Cac Out Pipeid 138 Both Sides Cart Part No D16.033.48.0.Pr , Joint For Cac Out Pipe Cart Part No D16.033.49.0.00 , Bracket For Cac Out Pipe Cart Part No D16.033.51.0.Pr , Cac Adaptor Bracket R H Cart Part No D16.033.53.0.00 , Cac Adaptor Bracket L H Cart Part No D16.033.54.0.00 , T Bolt Clampfor Dia 141 149 Cart Part No D16.033.55.0.Pr , Cac Pipe In ( From T/C To Radiator In) Cart Part No D16.033.56.0.Pr , O Ring Cart Part No D16.033.74.0.Pr , Compressor Out Pipe Cart Part No D16.033.75.0.Pr , Compressor Out Pipe Cart Part No D16.033.76.0.Pr , Mtg Foot Cart Part No D16.034.03.0.Pr , O Ring For Ladder In Cart Part No D16.036.07.0.00 , O Ringfor Ladder Oil Hole Cart Part No D16.036.08.0.Pr , Special Bolt For Ladderm14x2x175l Cart Part No D16.036.09.0.00 , O Ring For Ladder (Water Out) Cart Part No D16.036.14.0.00 , Sleevebetween Ladder And Crankcase Cart Part No D16.036.15.0.Pr , Spacer R H Between Cooler Header Ladder For 1250Kva Cart Part No D16.036.23.0.Pr , Spacer L H Between Cooler Header Ladder For 1250Kva Cart Part No D16.036.24.0.Pr , Lub Oil Coolerfor 1250Kva Cart Part No D16.036.38.0.Pr , Adaptorfor Centrifuge Pipe Cart Part No D16.041.02.0.00 , Centrifuge Oil In Pipe Cart Part No D16.041.10.0.00 , Delivary Adaptor Cart Part No D16.042.03.0.Pr , Joint Betdelivary Adaptor Ladder Cart Part No D16.042.04.0.Pr , Delivery Adaptor Cart Part No D16.042.05.0.00 , Clamp For Delivery Tube Cart Part No D16.042.06.0.00 , Clamp For Delivery Tube Cart Part No D16.042.07.0.00 , Sub Assembly Of Delivary Tubecenter Cart Part No D16.042.30.0.Pr , Suction Adaptor Cart Part No D16.043.01.0.Pr , Joint For Suction Cart Part No D16.043.02.0.Pr , Stainer Basket Cart Part No D16.043.04.0.Pr , Alternator Mtgbracket Cart Part No D16.044.01.0.Pr , Ccv Adaptor Cart Part No D16.046.01.0.00 , Ccv Mounting Bracket Cart Part No D16.046.09.0.00 , Ccv Hose Pipe In Cart Part No D16.046.13.0.Pr , Ccv Drain Pipe (Rh From Ge) Cart Part No D16.046.16.0.00 , Ccv Drain Pipe (Lh From Ge) Cart Part No D16.046.17.0.00 , Ccv Out Pipe Cart Part No D16.046.18.0.00 , Clamp For Ccv Drain Pipe Cart Part No D16.046.19.0.00 , Bracket For Ccv Cart Part No D16.046.21.0.00 , Ccv Out Elbow Cart Part No D16.046.22.0.Pr , Ccv Hose Pipe(Breather Hose To Air Cleaner Pipe) Cart Part No D16.046.23.0.00 , Ccv Connector (I. D. 20) Cart Part No D16.046.24.0.Pr , Joint Between Bell Housing & Adaptor Cart Part No D16.046.25.0.00 , Ccv Hose Pipe 2Breather Hose To Air Cleaner Pipe Cart Part No D16.046.26.0.Pr , Ccv Hose Pipe In 1 Cart Part No D16.046.27.0.Pr , Ccv Hose Pipe 2 Cart Part No D16.046.28.0.Pr , Breather Housing Cart Part No D16.046.34.0.Pr , Deflector Plate Cart Part No D16.046.35.0.Pr , Mounting Plate Cart Part No D16.046.36.0.Pr , Breather Platewith Holes Cart Part No D16.046.37.0.Pr , Brether Plate Cart Part No D16.046.39.0.Pr , Breather Mesh Plate For Brether Housing Cart Part No D16.046.41.0.Pr , Spacer For Heat Shield Cart Part No D16.051.07.0.00 , Heat Shield For Turbo Adaptorrhs Cart Part No D16.051.23.0.Pr , Heat Shield For Turbo Adaptorlhs Cart Part No D16.051.24.0.Pr , Idler Bracket Lh Cart Part No D16.052.01.0.Pr , Idler Pulley Cart Part No D16.052.02.0.00 , Idler Bracket Rh Cart Part No D16.052.07.0.Pr , Eye Bolt Cart Part No D16.052.09.0.00 , Idler Bracket With Pulleyasslyrh Cart Part No D16.052.10.0.Pr , Spacer 15X28 Cart Part No D16.052.12.0.00 , Pivot For Ideler Bracket Cart Part No D16.052.14.0.Pr , Shaft For Ideler Pulley Cart Part No D16.052.15.0.00 , Lever For Belt Tensioning Cart Part No D16.052.16.0.Pr , Idler Bracket With Pulleyasslylh Cart Part No D16.052.20.0.Pr , Ideler Mtgboltm12x1 75X185l Cart Part No D16.052.21.0.00 , Ideler Bracket Mtgbolt Cart Part No D16.052.22.0.00 , Bearing6007 2Rs1 C3gjn Cart Part No D16.052.23.0.Pr , Brass Set Screwm12 X 1 75 X 50 Cart Part No D16.052.31.0.Pr , Brass Nutm12 X 1 75 Cart Part No D16.052.32.0.Pr , Brass Washerm12 Cart Part No D16.052.33.0.Pr , Fuel Level Sensor Height 220 Mm With High Low Pressure Switch Cart Part No D16.057.06.0.Pr , Anti Vibration Mounts For D16 Cart Part No D16.061.06.0.Pr , Alternator Pulley Cart Part No D16.062.05.0.Pr , Bracket For Alternator Pulley Cart Part No D16.062.06.0.Pr , Expansion Bellow Cart Part No D16.064.04.0.Pr , Joint Between Diffuser And Bellow Cart Part No D16.064.05.0.Pr , Joint Between Silencer And Extension Pipe Cart Part No D16.064.09.0.Pr , Rain Cap Assembly For Tail Pipe Cart Part No D16.064.11.0.Pr , Exhaust Bend Cart Part No D16.064.13.0.Pr , Hose Between Thermostat Radiator In Cart Part No D16.064.14.0.Pr , Hose Cart Part No D16.064.18.0.Pr , Hose For Thermostat To He Out Pipe Cart Part No D16.064.19.0.Pr , Hose For Raw Water In Cart Part No D16.064.21.0.Pr , Spacer Plate Cart Part No D16.064.32.0.Pr , Silencer Assembly Cart Part No D16.064.50.0.Pr , Exhaust Pipe Flange Spacer Cart Part No D16.064.61.0.Pr , Exhaustbellow Cart Part No D16.064.62.0.Pr , Common Rail Fuel Pump Assly Cart Part No D16.072.60.0.00 , Wiring Box Assembly R H S From Pulley End Side Cart Part No D16.099.10.0.Pr , Wiring Box Assembly R H S From Pulley End Side Cart Part No D16.099.20.0.Pr , Engine Wiring Harness Box L Hfrom Pulley End Cart Part No D16.099.30.0.Pr , Wiring Harness Box Assembly Lhs From Pully End Side Cart Part No D16.099.50.0.Pr , Hose Cart Part No D16.505.14.0.Pr , Air Cleaner Support Cart Part No D16.505.18.0.Pr , Air Cleaner Support Cart Part No D16.505.19.0.Pr , Air Cleaner Support Cart Part No D16.505.21.0.Pr , Air Cleaner Mounting Top Support Cart Part No D16.505.26.0.Pr , Stay Rod For Air Cleaner Support Cart Part No D16.505.27.0.Pr , Stay Rod For Air Cleaner Support Cart Part No D16.505.28.0.Pr , Radiator Drain Pipe Cart Part No D16.505.33.0.Pr , Ecu Mounting Support Channel 1 Cart Part No D16.505.34.0.Pr , Air Filter Primary Cart Part No D16.505.41.0.00 , Air Filter Safety Cart Part No D16.505.42.0.00 , Hose Clamp -T Bolt For Air Cleaner 1010 Kva Cart Part No D16.505.46.0.00 , D16.505.47.0.Pr-Hose Clamp, T Bolt Dia.138.1 Cart Part No D16.505.47.0.Pr , Hose Elbow Cart Part No D16.505.48.0.Pr , Hose Cart Part No D16.505.52.0.00 , Support Bracket For Fuel Piping Cart Part No D16.505.53.0.Pr , Air Cleaner Hoseturbo To Air Cleaner Cart Part No D16.505.63.0.Pr , Air Cleaner Pipe From Hosel H Side Cart Part No D16.505.75.0.Pr , Air Cleaner Pipe From Hoser H Side Cart Part No D16.505.76.0.Pr , Air Cleaner Assembly (R.H) Side-18 Mettalic Cart Part No D16.505.80.0.00 , Air Cleaner Assembly (L.H) Side-18 Mettalic Cart Part No D16.505.90.0.00 , Air Cleaner Assembly For 1010 Kva Cart Part No D16.506.10.0.00 , Pre-Filter Cartridge Cart Part No D16.507.03.0.00 , Adaptor Cart Part No D16.507.07.0.Pr , Fuel Pre-Filter Cart Part No D16.507.10.0.00 , Fuel Pipefuel Tank To Leak Off Pipe Cart Part No D16.507.11.0.Pr , Fuel Pipefuel Tank To Leak Off Pipe Cart Part No D16.507.12.0.Pr , Fuel Pipe From Tank To External Fuel Tank Cart Part No D16.507.13.0.Pr , Adaptorm22x1 5 Both Side Cart Part No D16.507.14.0.Pr , Hose Cart Part No D16.507.33.0.Pr , Fuel Pipes From Tank To Prefilter Cart Part No D16.507.43.0.Pr , Fuel Pipes From Tank To Prefilter Cart Part No D16.507.44.0.Pr , Fuel Return Pipem16x1 5 Male Plug And M22x1 5 Union Nut Cart Part No D16.507.47.0.Pr , Koel Alternator, 1010Kva, 415Vac, 3 Phase, 50 Hz, 1500 Rpm, 40 Deg Cart Part No D16.701.20.0.Pr , Coolant Level Switchlow High Level With Led Cart Part No D16.812.17.0.Pr , Rh Lock For Canopy Door750 Kva And Above Cart Part No D16.850.111.0.Pr , Lh Lock For Canopy Door750 Kva And Above Cart Part No D16.850.112.0.Pr , Door Handle Suitable For Dv Cart Part No D16.850.51.0.Pr , Rmsremote Monitoring Systemunit S F Crdi With 2 Years Data Package Inclusive Cart Part No D16.858.11.0.Pr , Assembly For Krm Unit For Kg1500 With Pakage S F Crdi Cart Part No D16.858.12.0.Pr , Lbend Clip 25 Dia For Flexible Pipe Cart Part No D16.902.33.0.Pr , Battery Charger 15Amp 24V Cart Part No D16.902.34.0.Pr , Bracket For Relay Mounting Cart Part No D16.902.36.0.Pr , Bolt For 1010Kva Relay Mounting Bracket Cart Part No D16.902.37.0.Pr , Red Terminal Block Cart Part No D16.902.44.0.Pr , Black Terminal Block Cart Part No D16.902.45.0.Pr , Set Bolt For Flywheel Cart Part No D16.902.56.0.Pr , Earthing Cable Alternator To Base Plate 50X6mm1600mm Length Cart Part No D16.903.01.0.Pr , Earthing Cable For Radiator Cart Part No D16.903.04.0.Pr , 2 Channel, 3 Change Over, 24V, 10A Relay Board Cart Part No D16.903.13.0.00 , Battery Cables 95 Sqmm 650Mm Length Cart Part No D16.903.30.0.Pr , Control Panel Mouting Bracket Cart Part No D16.903.38.0.Pr , Canopy Wiring Harness Sf Dv 2X1010kva Optiprime Project Containerized Cart Part No D16.905.80.0.Pr , Nfc Link For D350 Avr Cart Part No D16.906.05.0.00 , Engine Wiring Harness Sf Control Panel To Interface Box Cart Part No D16.906.20.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection Cart Part No D16.906.50.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection Cart Part No D16.906.60.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection With Stana Cart Part No D16.906.70.0.Pr , Control Panel Assembly For Dv16 3Phase 1010Kva Crdi Silent Genset Cart Part No D16.908.30.0.Pr , Syncronization Panel With 1010Kva Crdi Genset Cart Part No D16.908.40.0.Pr , Wiring Harness From Slave Ecu To Sensor Cart Part No D16.909.20.0.Pr , Wiring Harness From Slave Ecu To Sensor Cart Part No D16.909.30.0.Pr , Wiring Harness From Master Ecu To Sensor Cart Part No D16.909.40.0.Pr , Control Panel To Dg2 Engine Wiring Harness Cart Part No D16.910.50.0.Pr , Control Panel To Dg1 Avr Harness Cart Part No D16.910.90.0.Pr , Control Panel To Dg2 Avr Harness Cart Part No D16.911.20.0.Pr , Control Panel To Incomer Breaker 1 Interface Harness Cart Part No D16.912.30.0.Pr , Control Panel To Incomer Breaker 2 Interface Harness Cart Part No D16.912.40.0.Pr , Power Cable Wiring For 2X1010kva Optiprime Genset Cart Part No D16.912.50.0.Pr , Dg1 Ct Wiring Harness For 2X1010kva Optiprime Genset Cart Part No D16.912.60.0.Pr , Dg2 Ct Wiring Harness For 2X1010kva Optiprime Genset Cart Part No D16.912.80.0.Pr , Kvaser Cable For Ecu_Crdi Set Cart Part No D16.999.05.0.Sp , Tool Kit For Software Programming Cart Part No D16.999.06.0.Sp , Wet Pm Kit (W/O Oil ) For D16.1024 Cart Part No D16.999.10.0.Sp , Crankshaft Complete- Dm20 Cart Part No D2.003.40.0.00 , L.O.Pipe(Crcase To Both Rsh) Cart Part No D2.008.10.0.00 , Joint: Suction Tube Cart Part No D2.009.06.0.00 , Suction Tube Assemblydm20 Cart Part No D2.009.10.0.00 , Alternator: 12V 35A Cart Part No D2.059.01.0.00 , Gear Pump: Dm20/Da20 Rr Cart Part No D2.141.40.0.00 , Flywheel Housing Cart Part No D2.147.01.0.00 , Flywheel Assly,Es,Sr - S/F Sae-2 Hsg. Cart Part No D2.148.10.0.00 , Flywheel Assly,Es,Sr - S/F Sae-3 Hsg. Cart Part No D2.149.10.0.00 , Flywheel Assembly Cart Part No D2.156.10.0.00 , Anti Vibration Mtg: Genset Cart Part No D2.163.01.0.00 , V Belt: Ax55 Cogged Cart Part No D2.164.02.0.00 , Core Plug 1 4 Bsp12 5 Length Cart Part No D2.301.02.0.00 , Joint: Cyl Head & Rbox Cart Part No D2.307.03.0.00 , Set Of Joints Cart Part No D2.323.40.0.00 , Leak Off Pipe: Injector To Bottom Fuel Tank Cart Part No D2.338.10.0.00 , Cyl Head Steel Gasket:Daf10 Cart Part No D3.003.06.0.00 , Push Rod Tube Assembly Cart Part No D3.005.20.0.00 , Le Top Bearing(With Hole) Cart Part No D3.030.02.0.00 , Small End Bush With Hole Cart Part No D3.030.03.0.00 , Connecting Rod Assly: Oil Hole Cart Part No D3.030.10.0.00 , Blower Asly.Rr-Da10 Cart Part No D3.032.10.0.00 , Crank Pulley (Finish)(Bolted Type)(175.4 Pcd) Cart Part No D3.036.03.0.00 , Wet Pm Kit (W/O Oil) For D3.1609.92 Cart Part No D3.160.9.0.Sp , Starter 12V Cart Part No D3.176.01.0.00 , Ignition Switch Cart Part No D3.213.08.0.00 , 25Amp Sp Mcb Cart Part No D3.213.17.0.00 , Mcb17 5Amp1 Pole Cart Part No D3.214.11.0.Pr , Koel Green Alternatorkg5 S T Framel Kg 40 C0sae 3 11 5 415V50 Hz0 8 Pf Cart Part No D3.229.24.0.Pr , Engine Monitoring System Unit Type - Ems926 - Volt. - 8 - 32V Dc Cart Part No D3.242.04.0.00 , Power Cablefor Ea10 5Kva 1Ph Emerald Cart Part No D3.242.22.0.Pr , Rra Condenser Diode & Varistor Cart Part No D3.247.01.0.Asp , Terminal Block Assembly- 5-10 Kva 1 Phase Cart Part No D3.247.02.0.Asp , De Brkt- Prot. Screen Asly-5/10Kva-1 Phase Cart Part No D3.247.05.0.Asp , Space Heater 54W, 230 V. Kva Rating:- (5 To 160 Kva) Cart Part No D3.247.12.0.Asp , Dsrl (Digital Simplified Regulator) For Frame Kg3,Kg28 Cart Part No D3.247.15.0.Asp , Koel Green Alternatorkg5 S S Framel Kg 40 C1sae 3 11 5 230V50 Hz0 8 Pf Cart Part No D3.247.25.0.Pr , Koel Green Alternator, Kg 7 S S, Frame Ls- Kg40 C2, Sae3 11.5, 230V, 50 Hz, 0.8 Pf (Ag3 Cart Part No D3.247.27.0.00 , Engine Wiring Harness Assembly: Ea10 Engine Suitable For Kg934 Control Unit Cart Part No D3.256.10.0.00 , Engine Wiring Harness Sf 5 & 7 Kva Ea10 Engine Cart Part No D3.256.40.0.00 , Engine Wiring Harness For Ea10 Emerald Cart Part No D3.256.50.0.Pr , Cylinder Head Stud (Long) Cart Part No D3.301.05.0.00 , Stud For Rocker Support Cart Part No D3.317.03.0.00 , Cylinder Head Assembly Cart Part No D3.317.20.0.00 , Valve Pair Cart Part No D3.317.99.0.00 , Shim: Liner To Cr Case 0.005Th Cart Part No D3.318.02.0.00 , Shim: Liner To Cr Case 0.010Th Cart Part No D3.318.03.0.00 , Shim: Liner To Cr Case 0.015Th Cart Part No D3.318.04.0.00 , Rocker Support Assly: Ea10 Cart Part No D3.319.30.0.00 , Button For Yoke Cart Part No D3.321.03.0.00 , Cowling Set Cart Part No D3.324.10.0.00 , Leak Off Connector Cart Part No D3.325.01.0.00 , Leak Off Pipe Assly: Crcase To Fwe Mb Hsg & Ext Rocker Support Cart Part No D3.326.10.0.00 , Set Of Joints Cart Part No D3.329.40.0.00 , Handle For Door Cart Part No D3.331.09.0.00 , Hinge For Door(Stainless Steel,Clinched Bolt) Cart Part No D3.331.18.0.00 , Cylinder Liner- Ea10 Cart Part No D3.335.01.0.00 , Hose For Air Cleaner Cart Part No D3.336.01.0.00 , Exh.Silencer S/F Single & Twin Cyl.Air-Cooled Ve Canopy Cart Part No D3.343.28.0.00 , Tail Pipe For Silencer Cart Part No D3.343.29.0.00 , Air Intake Adaptor Cart Part No D3.343.33.0.00 , Exhaust Bend(Lagged) - For Ea10,Ea20,Ew20,Ew24 & Ew28 Engines Cart Part No D3.343.34.0.00 , Inlet Pipe(Erw) Cart Part No D3.343.36.0.00 , Hose Air Intake Adaptor To Air Cleaner Cart Part No D3.343.37.0.00 , Exhaust Bendupward Opening Cart Part No D3.344.01.0.00 , Exhaust Silencer Cart Part No D3.344.02.0.00 , Silencer Assembly Cart Part No D3.344.35.0.Pr , Exhaust Manifold Cart Part No D3.345.03.0.00 , Joint Silencer Exh Pipe To Tail Pipe Cart Part No D3.345.05.0.00 , Tower Bolt, 4.0 Long(Brass) Cart Part No D3.345.07.0.00 , Blower Assemblyfor Ea 10 Cpcb Ii Cart Part No D3.351.10.0.Pr , Injector Assly Cart Part No D3.353.10.0.00 , Liner Piston Set: Ea10 3Rv Cart Part No D3.399.01.0.00 , Wet Pm Kit (W/O Oil) For D3.9616 - Daf10 Cart Part No D3.961.06.0.Sp , Wet Pm Kit (W/O Oil) For D3.1605.92 - Ea10 Cart Part No D3.999.12.0.Sp , Wet Pm Kit (W/O Oil) For D3.1610, D3.1630, D3.4866 - Ea10 Cart Part No D3.999.13.0.Sp , Wet Pm Kit (W/O Oil) For D3.4807, D3.5803, D3.9801,D3.9804 - Ea10 Cart Part No D3.999.14.0.Sp , Wet Pm Kit (W/O Oil ) For D3.1101 Cart Part No D3.999.25.0.Sp , Wet Pm Kit (W/O Oil) For D3.1609.92 D3.9615 D3.1605. D3.9616...92..- Ea10 G1 Cart Part No D3.999.42.0.Sp , Wet Pm Kit (W/O Oil) For D3.8301, D3.8323, D3.98324, D3.9618, D3.8322, D3.8324- Ea10g1 Cart Part No D3.999.50.0.Sp , Joint: Adaptor Inlet Mfold Cart Part No D4.007.06.0.00 , Blower Assembly Cart Part No D4.014.10.0.00 , Bracket For Fan Body Cart Part No D4.023.01.0.00 , Cooling Blower Assembly With Bracket Da20 Acwr Engine Cart Part No D4.023.30.0.00 , Spacer For Alternator Bracket Cart Part No D4.026.01.0.00 , Fuel Gauge Cart Part No D4.117.01.0.00 , Fuel Level Gauge Cart Part No D4.117.06.0.00 , Feed Pump Cart Part No D4.119.02.0.00 , Eccentric Cart Part No D4.119.05.0.00 , Joint: Feed Pump Cart Part No D4.119.09.0.00 , Gear Cover S/F Feed Pump - Vave Cart Part No D4.119.12.0.00 , Flywheel Housing Cart Part No D4.121.01.0.00 , Expansion Bellow: 285 Mm Cart Part No D4.122.01.0.00 , Expansion Bellow: 232Mm Double Flange Cart Part No D4.122.02.0.00 , Steel Joint: Exp Bellow Double Flange Cart Part No D4.122.03.0.00 , Crankshaft Gear Wheel Cart Part No D4.135.01.0.00 , Primary Air Cleaner Element Cart Part No D4.149.15.0.00 , Wet Pm Kit (W/O Oil) For D4.1610.91,D4.9615,D4.9801,D4.9803 Cart Part No D4.1610.91.0.Sp , Hose: Air Inlet Manifold Cart Part No D4.171.04.0.00 , Cam Shaft & Gear Assembly Cart Part No D4.302.30.0.00 , Camshaft Assly- Ea16-Ea20 Rr Cart Part No D4.302.40.0.00 , Wet Pm Kit (W/O Oil) For D4.5801,D8.8301,D8.8309.Pb,D8.9301,D8.9303 Cart Part No D4.580.1.0.Sp , Wet Pm Kit (W/O Oil) For D4.4804 - Ea20 Cart Part No D4.999.06.0.Sp , Wet Pm Kit (W/O Oil) For D4.1610.92 Cart Part No D4.999.08.0.Sp , Wet Pm Kit (W/O Oil) For D4.1616.92..D4.1615...- Ea20.2.Air Cart Part No D4.999.43.0.Sp , Piston Pin Cart Part No D5.006.02.0.00 , Bracket For Stop Solenoid Cart Part No D5.114.02.0.00 , Cylinder Head Gasket Ew8 5 Cart Part No D5.302.02.0.00 , Valve Guide(Semi-Finish) - Ew8.5 Cart Part No D5.302.03.9.00 , Ring Set Std: Ew8.5 3Rv Cart Part No D5.303.10.0.00 , Piston Assembly: Ew8.5 Cart Part No D5.303.20.0.00 , Joint: Air Inlet Mfold Cart Part No D5.304.02.0.00 , Gasket: Exhaust Mfold Ew8.5 Cart Part No D5.305.02.0.00 , Cylinder Liner Cart Part No D7.002.01.0.00 , Cyl Head Steel Gasket:Daf8 Cart Part No D7.003.06.0.00 , Push Rod Tube Assembly Cart Part No D7.005.10.0.00 , Valve Pair Cart Part No D7.302.99.0.00 , Rocker Cover Cart Part No D7.304.01.0.00 , Breather Cart Part No D7.304.03.0.00 , Joint: Rocker Cover Eaf8 7Ea10 Cart Part No D7.304.04.0.00 , Flange For Nozzle Cart Part No D7.305.01.0.00 , Rocker Support Sub Assly: Eaf8 Cart Part No D7.306.40.0.00 , Assly Camshaft Sr Stl A2 1500 Eaf8 Ea10 Cart Part No D7.309.30.0.00 , Cylinder Head Stud (Short) Cart Part No D7.310.01.0.00 , Inlet Valve Assly Cart Part No D7.311.01.0.00 , Inlet Valve Seat Insert (Cpcb) Cart Part No D7.311.02.0.00 , Inlet Valve Seat Insert(Semi-Finish) - Eaf8 Cart Part No D7.311.02.9.00 , Exhaust Valve(Finish) - Eaf8 Cart Part No D7.312.01.0.00 , Exhaust Valve Seat Insert(Semi-Finish) - Eaf8 Cart Part No D7.312.02.9.00 , H.P. Pipe Assly G.E.Side:Eaf8/Ea10 Cart Part No D7.313.10.0.00 , Cyl.Liner,Optimised Fins(Std)(Finish) - Eaf8 Cart Part No D7.317.01.0.00 , Wet Pm Kit (W/O Oil) For D3.8304 - Ea10 Cart Part No D7.999.03.0.Sp , Temp. Switch - 230 Deg. C Cart Part No D8.066.01.0.00 , Exh Fan: 450Mm With Connector Cart Part No D8.079.26.0.00 , Tube Light 12V Dc,6 Long For Canopy With Connector Cart Part No D8.079.48.0.00 , Tube Light 24V Dc,6 Long For Canopy With Connector Cart Part No D8.079.49.0.00 , Led Tube Light12vdc2w6long With 2 Pin Connector Cart Part No D8.079.52.0.Pr , Koel Green Alternator, Kg 10 S S Frame: L Kg 40 E, Sae-2 11.5, 230V, 50 Hz, 0.8 Pf Cart Part No D8.105.19.0.00 , Koel Green Alternatorkg 10 S T Framel Kg 40 C2sae 2 11 5 415V50 Hz0 8 Pf Cart Part No D8.106.19.0.Pr , Fip: Ea16 Cpcb-Ii Cart Part No D8.111.01.0.00 , Koel Green Alternator, Kg 12.5 S S Frame: L Kg 423 B, Sae-2 11.5, 230V, 50 Hz, 0.8 Pf Cart Part No D8.117.23.0.00 , Relay Card - 2.5 Channel - 12V Dc Cart Part No D8.138.18.0.00 , Wet Pm Kit (W/O Oil) For D8.1605.91,D8.4812.91,D8.4813.91,D8.5801,D8.5802,D8.9804,D8.9804.0 Cart Part No D8.1605.91.0.Sp , Wet Pm Kit (W/O Oil) For D8.1612.92 Cart Part No D8.1612.92.0.Sp , Starter12vstmrvh 1104 Cart Part No D8.176.01.0.Pr , Control Panel Schematic For 12 5Kva3ph With Kg640 Ip A Cart Part No D8.190.70.0.Pr , Control Panel Schematic For 12 5Kva1ph With Kg640 Ip A Cart Part No D8.190.80.0.Pr , Terminal Barag3080650000 Rating10 251 Phframekg164 J Kg 184 A B D E Cart Part No D8.191.02.0.00 , Engine Wiring Harness Assembly Cart Part No D8.256.10.0.00 , Engine Wiring Harness Assembly Cart Part No D8.256.30.0.00 , Engine Wiring Harness For Ea16 Emerald Cart Part No D8.256.70.0.Pr , Engine Wiring Harness For Ea16 Cart Part No D8.256.80.0.Pr , Power Harness For Ea16 3Ph Engine Emrald Cart Part No D8.258.40.0.Pr , Power Harness For Ea16 1Ph Engine Emrald Cart Part No D8.258.50.0.Pr , Crankcase Assembly Cart Part No D8.301.10.0.00 , Air Inlet Manifoldfinishaluminumea16 Cart Part No D8.303.11.0.00 , Cowling Set Cart Part No D8.305.20.0.00 , Special Banjo Bolt -M6 Cart Part No D8.306.02.0.00 , Lube Oil Pipe Assly: Crcase To Rocker Support Cart Part No D8.306.10.0.00 , Exhaust Manifold (Lagged) (Upward Opening) Cart Part No D8.307.05.0.00 , Special Socket Head Set Screw 5 16Bsf X 1 Copper Coated Cart Part No D8.307.06.0.00 , Fuel Pipe Feed Pump To Filter Cart Part No D8.308.07.0.00 , Fuel Pipe Nozzle To Tank Cart Part No D8.308.08.0.00 , Fuel Pipe Tank To Feed Pump Cart Part No D8.308.09.0.00 , Nozzle Leak Off Pipe Assembly - Ea16 Cart Part No D8.308.20.0.00 , Set Of Joints Cart Part No D8.312.40.0.00 , Fuel Pump Bracket Cart Part No D8.316.01.0.00 , Air Cleaner Element Cart Part No D8.319.03.0.00 , Hose For Cleaner Cart Part No D8.319.05.0.00 , Air Cleaner Assly: Dry Type Cart Part No D8.319.10.0.00 , Fuel Pipe (Feed Pump To Spinon Filter) Cart Part No D8.334.01.0.00 , Fuel Pipe (Spinon Filter To Fuel Pump) Cart Part No D8.334.02.0.00 , Blower Assembly With Bracket (Ea16 Cpcb Ii) Cart Part No D8.372.40.0.Pr , Liner Piston Set: Ea16 3Rv Cart Part No D8.399.01.0.00 , High Pressure Pipe Assembly Cart Part No D8.712.10.0.00 , V Belt Ax56 Cog Cart Part No D8.714.03.0.00 , Cylinder Head Assly Complete For Ea16 Cpcb Ii Engine Cart Part No D8.715.20.0.Pr , Wet Pm Kit (W/O Oil) For D8.8324 Cart Part No D8.832.4.0.Sp , Wet Pm Kit (W/O Oil ) For D8.9801 Cart Part No D8.999.10.0.Sp , Piston Pin Chetak Cart Part No D9.006.02.0.00 , Koel Green Alternatorkg 7 5 S S Framel Kg 40 C2sae 2 11 5 230V50 Hz0 8 Pf Cart Part No D9.061.14.0.Pr , Koel Green Alternatorkg 7 5 S T Framel Kg 40 C1sae 2 11 5 415V50 Hz0 8 Pf Cart Part No D9.062.18.0.Pr , Gasket: Cylinder Head Ew12 Cart Part No D9.302.02.0.00 , Ring Set Std: Ew12 3Rv Cart Part No D9.303.10.0.00 , Piston Assembly: Ew14 Cart Part No D9.303.20.0.00 , Cyl Liner Assembly-Ew14 Cart Part No D9.311.10.0.00 , Set Of Joints Cart Part No D9.312.40.0.00 , Valve Pair Cart Part No D9.322.99.0.00 , Wet Pm Kit (W/O Oil) For D9.4806.91, D9.4807.91 - Ew14 Cart Part No D9.999.08.0.Sp , Wet Pm Kit (W/O Oil) For D1.4810.91, D9.1606, D9.5801, D9.4810.91, D1.4809.91, D9.4811.91 - E Cart Part No D9.999.10.0.Sp , Wet Pm Kit (W/O Oil) For D9.1615 Cart Part No D9.999.11.0.Sp , Leak Off Pipe Assly Cart Part No Dc.004.10.0.00 , Radiator Assly With Shroud Dm26 Cart Part No Dc.033.10.0.00 , Adaptor Plate For Lube Oil Filter Cart Part No Dc.034.02.0.00 , Joint: Bween Adaptor & Crcase Cart Part No Dc.034.04.0.00 , Hose: Radiator Btm Tank To Thermostat Pipe Cart Part No Dc.123.01.0.00 , Hose: Water Pump Outlet To Wi Manifold Cart Part No Dc.123.02.0.00 , Hose: Thermostat Bypass To Bend Pipe Cart Part No Dc.123.04.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No Dc.305.01.0.00 , Fuel Pipe- Filter To Fip Cart Part No Dc.305.02.0.00 , Adaptor (For Overflow Valve) Cart Part No Dc.305.07.0.00 , Fuel Pipe Filter To Tank Cart Part No Dc.305.08.0.00 , Liner Piston Set: Ew28 3Rv Cart Part No Dc.399.01.0.00 , Wet Pm Kit (W/O Oil) For Dc.5801, D2.9620 - Ew28 Cart Part No Dc.999.20.0.Sp , Wet Pm Kit (W/O Oil) For Dc.1606.91, Dc.1605.91 Cart Part No Dc.999.21.0.Sp , Wet Pm Kit (W/O Oil) For Dc.9804, Dc.9803 - Ew28 Cart Part No Dc.999.22.0.Sp , Crank Pulley (Finish)(Bolted Type)(175.4 Pcd) Cart Part No Dd.019.03.0.00 , Bolt (Bearing Cap) Cart Part No Dv0.001.03.0.00 , Hollow Dowel(For Bearing Cap Bolt) Cart Part No Dv0.001.04.0.00 , Nozzle Body: Oil Spray Nozzle Cart Part No Dv0.001.05.0.00 , Special Banjo Bolt : Oil Spray Nozzle Cart Part No Dv0.001.06.0.00 , Lifting Hook Cart Part No Dv0.001.08.0.00 , Special Banjo Boltfor Oil Spay Nozzle Cart Part No Dv0.001.09.0.Pr , Crank Case Sub-Assembly Cart Part No Dv0.001.10.0.00 , Thrust Washertop Cart Part No Dv0.001.13.0.00 , Thrust Washerbottom Cart Part No Dv0.001.14.0.00 , Cam Bush Cart Part No Dv0.001.15.0.00 , Core Plug Hex Socket (M24x2) Cart Part No Dv0.001.16.0.00 , Core Plug Hex. Socket M33x3.5 Cart Part No Dv0.001.17.0.00 , Core Plug Hex. Socket M30x1.5 Cart Part No Dv0.001.18.0.00 , Grommet: 12 Dia Ferrule Cart Part No Dv0.001.21.0.00 , Grommet: 22 Dia Ferrule Cart Part No Dv0.001.22.0.00 , Ferrule: 12 Dia Cart Part No Dv0.001.23.0.00 , Ferrule: 22Dia Cart Part No Dv0.001.24.0.00 , Dish Plug (80Dia) Cart Part No Dv0.001.25.0.00 , Washer For Crankcase Plug Cart Part No Dv0.001.26.0.00 , Plug (Crankcase Oil Hole) Cart Part No Dv0.001.27.0.00 , Crank Case Assembly Cart Part No Dv0.001.30.0.00 , Spring Cart Part No Dv0.001.31.0.00 , Plunger: Relief Valve Cart Part No Dv0.001.32.0.00 , M.B. Cross Bolt (Long) Cart Part No Dv0.001.42.0.00 , M.B. Cross Bolt (Short) Cart Part No Dv0.001.43.0.00 , Sealing Cap Cart Part No Dv0.001.47.0.00 , Relief Valve Assly Cart Part No Dv0.001.50.0.00 , Main Bearing Top ( Miba) Cart Part No Dv0.001.51.0.00 , Main Bearing Lower Half - Sputter+Syntec Cart Part No Dv0.001.77.0.00 , Grommet Support Washer-20.2 Cart Part No Dv0.001.81.0.00 , Grommet Support Washer-31.5D Cart Part No Dv0.001.82.0.00 , Grommet For 12Diaferrule Cart Part No Dv0.001.83.0.00 , Grommet Support Washer For 31 5 Cart Part No Dv0.001.85.0.00 , O Ring: Cylinder Liner Cart Part No Dv0.002.02.0.00 , Scraper Ring Cart Part No Dv0.002.04.0.00 , Cylinder Liner Assembly Cart Part No Dv0.002.10.0.Sp , Cylinder Liner Assembly Cart Part No Dv0.002.30.0.00 , Dowel Cart Part No Dv0.003.04.0.00 , Crankshaft Sub Assly. Cart Part No Dv0.003.10.0.00 , Crank Pulley Cart Part No Dv0.003.12.0.00 , Crank Pulley For Fan Drive Cart Part No Dv0.003.13.0.00 , Crank Pulley Bolt Cart Part No Dv0.003.14.0.00 , Special Bolt (For Cam Shaft) Cart Part No Dv0.004.06.0.00 , Thrust Plate: Cam Shaft: Width 18.2 Cart Part No Dv0.004.09.0.00 , Thrust Plate: Cam Shaft: Width 18.7 Cart Part No Dv0.004.11.0.00 , Thrust Plate For Camshaft17 5 Mm Thick Cart Part No Dv0.004.13.0.00 , Thrust Plate For Camshaft17 3 Mmthick Cart Part No Dv0.004.14.0.00 , Camshaft With Internal Egr With 1.25 Mm Secondary Lift Cart Part No Dv0.004.24.0.00 , Connecting Rod Bolt Cart Part No Dv0.005.02.0.00 , Big End Bearing Top Miba Cart Part No Dv0.005.11.0.00 , Big End Bearing Bottommiba Cart Part No Dv0.005.12.0.00 , Connecting Rod Assly.With Small End Bushwith Large End Bearing Cart Part No Dv0.005.20.0.00 , Assy. Connecting Rod (Machining With Small End Bush) (For Crdi Engine) Cart Part No Dv0.005.60.0.00 , Piston Pin Cart Part No Dv0.006.02.0.00 , Circlip(For Piston) Cart Part No Dv0.006.06.0.00 , Piston Ring Set Cart Part No Dv0.006.20.0.Sp , Piston Assembly Cart Part No Dv0.006.30.0.00 , Cylinder Head Bolt Cart Part No Dv0.007.02.0.00 , Core Plug (20 Mm Dia) Cart Part No Dv0.007.03.0.00 , Exhaust Valve Cart Part No Dv0.007.05.0.00 , Inlet Valve Seat Insert Semi-Finish Cart Part No Dv0.007.06.9.00 , Core Plug (Dia 32 Mm) Cart Part No Dv0.007.09.0.00 , Cylinderhead Gasket1 2 Thick Cart Part No Dv0.007.11.0.00 , Rocker Lever Adj. Screw Assly. Cart Part No Dv0.007.110.0.00 , Union Adaptor M12xm8 Cart Part No Dv0.007.113.0.00 , Nozzle Clamp Cart Part No Dv0.007.114.0.Pr , Nutfor Rocker Lever Adjscrew Cart Part No Dv0.007.18.0.00 , Bushrocker Lever Cart Part No Dv0.007.21.0.00 , Cylinder Head Sub Assembly (With Valve Seat & Valve Guide) Cart Part No Dv0.007.220.0.00 , Cylinder Head Sub Assemblywith Valve Spring Valvefor Cr Cart Part No Dv0.007.230.0.Pr , Cylinder Head Assembly Cart Part No Dv0.007.260.0.Pr , Nozzle Clamp Cart Part No Dv0.007.33.0.00 , Button For Nozzle Clamp Cart Part No Dv0.007.34.0.00 , Cup Washer For Nozzle Clamp Cart Part No Dv0.007.35.0.00 , Oil Metering Plug: Rocker Support Cart Part No Dv0.007.36.0.00 , Exhaust Valve Seat Insert Cart Part No Dv0.007.39.9.00 , Gasket: Cylinder Head 1 Thk Cart Part No Dv0.007.42.0.00 , Gasket: Cylinder Head 1.15 Thk Cart Part No Dv0.007.43.0.00 , Sealing Cap Cart Part No Dv0.007.46.0.00 , Rocker Lever Asslembly Cart Part No Dv0.007.60.0.00 , Valve Pair Cart Part No Dv0.007.65.0.00 , Cyl Head Sub Assemblywith Spring Valve Cart Part No Dv0.007.70.0.00 , Sealing Cap (For Dia 25) Cart Part No Dv0.007.71.0.00 , Cylinder Head Assly Cart Part No Dv0.007.75.0.00 , Valve Guidefinish Cart Part No Dv0.007.82.0.00 , Valve Guide (Semi-Finish) Cart Part No Dv0.007.82.9.00 , Cylinder Head Assembly Cart Part No Dv0.007.90.0.00 , Cylinder Head Bolt Cart Part No Dv0.007.93.0.00 , Lifting Hook Cart Part No Dv0.007.94.0.00 , Inlet Valvebimetal Cart Part No Dv0.007.96.0.00 , Inlet Valvebimetal Cart Part No Dv0.007.96.0.Pr , Inlet & Exhaust Valve Pair Cart Part No Dv0.007.96.0.Sp , Valve Seat Insert (Exhaust) (Semifinish) Cart Part No Dv0.007.98.9.00 , Injector Cart Part No Dv0.008.13.0.00 , O Ring For Injector Cart Part No Dv0.008.18.0.00 , Joint: Rocker Cover Metallic Cart Part No Dv0.009.05.0.00 , Rocker Cover Cart Part No Dv0.009.07.0.00 , Rocker Box Cart Part No Dv0.009.11.0.00 , Retainer Patefor Gear Support Cart Part No Dv0.010.03.0.00 , Thrust Washer: Intermediate Gear Support Cart Part No Dv0.010.04.0.00 , Thrust Washer: Intermediate Gear Support Cart Part No Dv0.010.06.0.00 , Double Gear Asslycrank Gear And Cam Gear Cart Part No Dv0.010.20.0.00 , Double Gear Support Cart Part No Dv0.010.25.0.Pr , Intermediate Gear Support Cart Part No Dv0.011.03.0.00 , Thrust Washer(39Mm Thick) Cart Part No Dv0.011.04.0.00 , Oil Seal Housing Cart Part No Dv0.012.01.0.00 , Joint: Oil Seal Housing Cart Part No Dv0.012.03.0.00 , Deflector For Pulley End Cart Part No Dv0.012.08.0.00 , Oil Seal Housing (Sub Assy) Cart Part No Dv0.012.11.0.00 , Oil Seal Pulley End Cart Part No Dv0.012.22.0.Pr , Int Gear Supportfor Lub Oil Pump Gear Cart Part No Dv0.013.08.0.00 , Lub Oil Pump Assebly Cart Part No Dv0.013.200.0.00 , Bush For Intgearlop Cart Part No Dv0.013.22.0.00 , Lube Oil Cooler (17 Plates) Cart Part No Dv0.014.01.0.00 , Lub Oil Cooler Header Cart Part No Dv0.014.04.0.Sp , Filter Header Cart Part No Dv0.014.05.0.00 , Joint: Cooler Cover Cart Part No Dv0.014.06.0.00 , Threaded Adaptor For Header Cart Part No Dv0.014.07.0.00 , Suction Tube Cart Part No Dv0.014.08.0.00 , Lub Oil Filter Header Asslywith Adaptor Core Plug Cart Part No Dv0.014.10.0.00 , Lube Oil Filter Cart Part No Dv0.014.11.0.00 , O Ring 38 Dia: L.O. Header Cart Part No Dv0.014.12.0.00 , O Ring 58 Dia: L.O. Header Cart Part No Dv0.014.13.0.00 , O Ring 67 Dia: L.O. Header Cart Part No Dv0.014.14.0.00 , Joint: Water Pump Suction Cart Part No Dv0.014.16.0.00 , Gasket (Lub. Oil Header) Cart Part No Dv0.014.17.0.00 , Joint: Suction Pipe Assly Cart Part No Dv0.014.18.0.00 , O Ring 29Dia: Element Oil Cooler Cart Part No Dv0.014.23.0.00 , Hose: Radiator To Suction Pipe Cart Part No Dv0.014.24.0.00 , Hose: Engine Water Out Cart Part No Dv0.014.25.0.00 , Metalic Pipe From Thermostat To Rad Cart Part No Dv0.014.26.0.00 , Lube Oil Filter Cart Part No Dv0.014.27.0.00 , Hose: Pipe To Thermostat Cart Part No Dv0.014.33.0.00 , Header For Oil Filter (320 Kva) Cart Part No Dv0.014.38.0.00 , Lube Oil Cooler Cover (Machining) Cart Part No Dv0.014.39.0.00 , Oil Filter Cart Part No Dv0.014.42.0.00 , Dome Nut: Lub Oil Cooler Cart Part No Dv0.014.43.0.00 , Lub Oil Cooler Header Assly Cart Part No Dv0.014.50.0.00 , Joint: Cooler Cover Cart Part No Dv0.014.51.0.00 , Lube Oil Filter Full Flow Spin On Cart Part No Dv0.014.66.0.00 , Lube Oil Filter By Pass Spin On Cart Part No Dv0.014.67.0.00 , Adaptor (For Lube Filter) (Full Flow Side) Cart Part No Dv0.014.68.0.Pr , Adaptor (For Lube Filter) (By-Pass Side) Cart Part No Dv0.014.69.0.Pr , Lube Oil Filter-Full Flow-Spin On Kirloskar Logo Reversal Application Cart Part No Dv0.014.72.0.Pr , 500 Hrs - B Check Maintenance Kit Cart Part No Dv0.014.83.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv0.014.85.0.Sp , 50 Hours Service Maintenance Kit Cart Part No Dv0.014.86.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv0.014.89.0.Sp , Thermostat Element Cart Part No Dv0.015.01.0.00 , Thermostat Housing Cart Part No Dv0.015.02.0.00 , Thermostat Housing Cover Cart Part No Dv0.015.03.0.00 , Joint: Thermostat Housing Cart Part No Dv0.015.05.0.00 , Gasket: Thermostat Cover Cart Part No Dv0.015.06.0.00 , Washer: Thermostat Housing Assly Cart Part No Dv0.015.07.0.00 , Thermostat Housing Cart Part No Dv0.015.12.0.Pr , Thermostat Housing Cover Cart Part No Dv0.015.17.0.Pr , V Belt: Bx58 Pitch 1520 Long Cart Part No Dv0.016.08.0.00 , Joint:Bet Water Pump Hsg & Header Cart Part No Dv0.016.09.0.00 , Water Pump Pulley-115 Pcd Cart Part No Dv0.016.21.0.00 , V Wrapped Belt Ar1170 Spb Cart Part No Dv0.016.23.0.00 , V Wrapped Belt: Spb Ar1230 - 3 Set Cart Part No Dv0.016.25.0.00 , Fan Drive Belt (Bx 1230Lp Ar X 3) Cart Part No Dv0.016.27.0.Pr , Deep Groove Ball Brg. Cart Part No Dv0.016.36.0.Pr , Belt V Section (Bx 58- Pitch Length 1530 Mm) Cart Part No Dv0.016.42.0.Pr , Water Pump Assly Cart Part No Dv0.016.60.0.00 , Lube Oil Sump Cart Part No Dv0.017.03.0.00 , O Ring For Dipstick Plug Cart Part No Dv0.017.07.0.00 , Dipstick Assly Cart Part No Dv0.017.30.0.00 , Dipstick Assembly Cart Part No Dv0.017.80.0.00 , Dipstick Assly Cart Part No Dv0.017.90.0.Pr , Tappet Cart Part No Dv0.018.01.0.00 , Push Rod Assly Cart Part No Dv0.018.10.0.00 , Rubber Bush :Bottom Cart Part No Dv0.018.11.0.00 , Assly Push Rod Cover Tube Cart Part No Dv0.018.20.0.00 , Rubber Bush Bottom Cart Part No Dv0.018.23.0.00 , Push Rod Cover Tube Assembly (For Common Rail ) Cart Part No Dv0.018.40.0.00 , Fuel Pump Cap Cart Part No Dv0.019.11.0.00 , Fuel Filter: Dv10 Cart Part No Dv0.020.01.0.00 , Fuel Filter Cartridge Cart Part No Dv0.020.03.0.00 , High Pressure Pipe Assembly Cart Part No Dv0.021.130.0.00 , Clamp Cover For H Ppipe Cart Part No Dv0.021.52.0.Pr , Rubber Sleeve For H.P. Pipe Clamp Cart Part No Dv0.021.53.0.00 , High Pressure Pipes Assembly Cart Part No Dv0.021.710.0.Pr , Hp Pipe Assemblyfor Cyl1 Cart Part No Dv0.021.75.0.Pr , Hp Pipe Assemblyfor Cyl2 Cart Part No Dv0.021.76.0.Pr , Hp Pipe Assemblyfor Cyl3 Cart Part No Dv0.021.77.0.Pr , Hp Pipe Assemblyfor Cyl6 Cart Part No Dv0.021.78.0.Pr , Hp Pipe Assemblyfor Cyl7 Cart Part No Dv0.021.79.0.Pr , Hp Pipe Assemblypump To Rail Lhs From Fwe Cart Part No Dv0.021.81.0.00 , Hp Pipe Assly (Pump To Rail Rh From Fwe) Cart Part No Dv0.021.82.0.Pr , Rail Assembly 1 (Pulley End) Cart Part No Dv0.021.86.0.Pr , Adaptorone Side M16x1 5 Other Side M14x1 5 Cart Part No Dv0.022.05.0.00 , Elbow Connection (M16x15) Cart Part No Dv0.022.06.0.00 , Oil Supply Pipecrankcase To Fuel Pump In Cart Part No Dv0.022.102.0.Pr , Adaptor With Ferrule & Nut Assly Cart Part No Dv0.022.103.0.Pr , Adaptor With Ferrule & Nut Assly Cart Part No Dv0.022.106.0.Pr , Elbow Connection Cart Part No Dv0.022.108.0.Pr , Fuel Pipe Assly Flexible Cart Part No Dv0.022.110.0.00 , Hose For Oil Pipe Cart Part No Dv0.022.118.0.Pr , Nozzle Leak Off Pipe Cart Part No Dv0.022.15.0.00 , Fuel Pipe For Nozzle Leak Off Cart Part No Dv0.022.155.0.Pr , Parkar: Ge10lredcf Cart Part No Dv0.022.171.0.Pr , Parkar: G10lcfx Cart Part No Dv0.022.175.0.Pr , Parkar: Rhd10lomdcf Cart Part No Dv0.022.179.0.Pr , Parkar: Rbp110x Cart Part No Dv0.022.181.0.Pr , Adaptorfor Fuel Pipe Cart Part No Dv0.022.182.0.Pr , Bracket-1 Cart Part No Dv0.022.185.0.00 , Bracket Cart Part No Dv0.022.188.0.Pr , Bracket Cart Part No Dv0.022.189.0.00 , Clamp (2P) Cart Part No Dv0.022.191.0.Pr , Bracket Cart Part No Dv0.022.192.0.Pr , Hose For Intake 1 Cart Part No Dv0.022.194.0.Pr , Metal Tube (For Fuel Intake-1) Cart Part No Dv0.022.195.0.00 , Hose For Intake 2 Cart Part No Dv0.022.196.0.Pr , Metal Tube (For Fuel Intake-2) Cart Part No Dv0.022.197.0.00 , Hose For Fip Return Cart Part No Dv0.022.198.0.Pr , Metal Tube (For Fip Return) Cart Part No Dv0.022.199.0.00 , Bracket (For Lp Pipe-7) Cart Part No Dv0.022.202.0.Pr , Metal Tubefor Nozzle Leakoff Cart Part No Dv0.022.203.0.Pr , Injector Leak Off Pipe Cart Part No Dv0.022.204.0.Pr , Clamp For Fuel Pipe (Id19.5) Cart Part No Dv0.022.206.0.00 , Bracket Mtg. Plate Cart Part No Dv0.022.207.0.Pr , Bracket Cart Part No Dv0.022.208.0.Pr , Bracket Cart Part No Dv0.022.209.0.Pr , Plate For Clamp Cart Part No Dv0.022.211.0.Pr , Injector Leakoff Pipea Bank Cart Part No Dv0.022.213.0.Pr , Injector Leakoff Pipeb Bank Cart Part No Dv0.022.214.0.Pr , Fuel Pipefrom Tee To Tank Interface Cart Part No Dv0.022.215.0.Pr , Fuel Pipefrom Filter To Pump Lh From Fe Cart Part No Dv0.022.216.0.Pr , Fuel Pipefrom Filter To Adaptor Rh From Fe Cart Part No Dv0.022.217.0.00 , Fuel Pipe(From Adaptor To Pump Rh From F.E.) Cart Part No Dv0.022.218.0.Pr , Pump Leak Off Pipe-1 (Lh From F.E.) Cart Part No Dv0.022.219.0.Pr , Pump Leak Off Pipe-2 (Lh From F.E.) Cart Part No Dv0.022.221.0.Pr , Pump Leak Off Piperh From F E Cart Part No Dv0.022.222.0.Pr , Rail Leak Off Pipe Assembly Cart Part No Dv0.022.226.0.Pr , Dearation Pipe 1 A Bank Cart Part No Dv0.022.228.0.Pr , Dearation Pipe 2 B Bank Cart Part No Dv0.022.229.0.Pr , Adaptor M18*1.5-M14*1.5 (For Fuel Pump Oil Drain Pipe) Cart Part No Dv0.022.47.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv0.022.71.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No Dv0.022.72.0.00 , Feed Pump Fuel In Pipe: Flex Cart Part No Dv0.022.73.0.00 , Fuel Pipe: Pump Leak Off (Flex) Cart Part No Dv0.022.74.0.00 , Fuel Pipe: Nozzle Leak Off Flex Cart Part No Dv0.022.76.0.00 , Clamp For Low Pressure (3 Pipe) Cart Part No Dv0.022.77.0.00 , Rubber Sleeve For Low Pressure 3 Pipe Clamp Cart Part No Dv0.022.78.0.00 , Clamp 2 Pipe Cart Part No Dv0.022.86.0.00 , Drain Pipe (For Diesel Drain) Cart Part No Dv0.022.94.0.00 , Joint: Main Air Pipe To Inlet Manifold Cart Part No Dv0.023.02.0.00 , Joint: Bet Inlet Manifold & Cyl Head Cart Part No Dv0.023.03.0.00 , Cover Platefor Inlet Manifold Cart Part No Dv0.023.06.0.00 , Inlet Manifold 2 Port Cart Part No Dv0.023.08.0.00 , Inlet Manifold 3 Port Cart Part No Dv0.023.09.0.00 , Expansion Bellow Cart Part No Dv0.023.11.0.00 , Air Pipe Clamp (Bottom) Cart Part No Dv0.023.12.0.00 , Air Pipe Clamp (Top) Cart Part No Dv0.023.13.0.00 , Rubber Bush Cart Part No Dv0.023.14.0.00 , Expansion Bellow: Exp Mfold Cart Part No Dv0.024.05.0.00 , Joint: Exh Mani & Adaptor Cart Part No Dv0.024.06.0.00 , Joint: Exh.Mani And Cyl. Head Cart Part No Dv0.024.07.0.00 , Joint: Bet Exh Mfold & Exp Bellow Cart Part No Dv0.024.08.0.00 , Joint: Bet Exh Mfold & Cyl Head Cart Part No Dv0.024.09.0.00 , Joint: Bet Exh Mfold & Cyl Head Cart Part No Dv0.024.15.0.00 , Special Nut For Exhaust Manifold Cart Part No Dv0.024.18.0.00 , Stud: Exhaust Manifold Cart Part No Dv0.024.19.0.00 , Joint: Bet Exh Mfold & Cyl Head Cart Part No Dv0.024.22.0.00 , Exhaust Manifoldl H3 Port Cart Part No Dv0.024.24.0.00 , Exhaust Manifold (L.H. 2 Port) Cart Part No Dv0.024.25.0.00 , Exhaust Manifoldr H3 Port Cart Part No Dv0.024.26.0.00 , Exhaust Manifoldr H2 Port Cart Part No Dv0.024.27.0.00 , Jointbetturbo Adaptor Exhaust Manifold Cart Part No Dv0.024.35.0.00 , Joint: Gear Casing Cart Part No Dv0.025.03.0.00 , Socket Head Screw (M12 X 165) Cart Part No Dv0.025.05.0.00 , Gear Cover Cum Bell Housing Cart Part No Dv0.025.14.0.00 , Deflector Cart Part No Dv0.025.17.0.00 , Oil Seal Flywheel End Cart Part No Dv0.025.18.0.Pr , Deflector For Flywheel End Cart Part No Dv0.025.19.0.Pr , Mud Slinger Fwe Cart Part No Dv0.025.21.0.Pr , Gear Cover Cum Bell Housing Dv0 025 23 0 Pr Cart Part No Dv0.025.23.0.Spr , Gear Casingfor Dv10 Crdi Cart Part No Dv0.025.25.0.00 , Bolt: Flywheel Cart Part No Dv0.026.02.0.00 , Washer (For Flywheel Bolt) Cart Part No Dv0.026.04.0.00 , Sub Asslyof Flywheel And Starter Ring Cart Part No Dv0.026.50.0.00 , Special Stud (For Starter) Cart Part No Dv0.027.03.0.00 , Starter 50Mt Cart Part No Dv0.027.11.0.00 , Lucas Starter 9 0Kw Sm50 Series For Dv Engine Cart Part No Dv0.027.12.0.Pr , Starterdelco Remy 50Mt Reil Series R50 Type 400Rdso Specs Rdso Pe Spec Ac Cart Part No Dv0.027.13.0.Pr , Prestolite Starter 9Kw Ms7 303K Design Cart Part No Dv0.027.14.0.Pr , Fan Pulley Cart Part No Dv0.029.01.0.00 , Bracket For Fan Drive Mounting Cart Part No Dv0.029.03.0.00 , Shaft: Radiator Fan Cart Part No Dv0.029.04.0.00 , Washer (For Fan Drive Pulley) Cart Part No Dv0.029.06.0.00 , Special Stud Cart Part No Dv0.029.07.0.00 , Fan Spacer Cart Part No Dv0.029.15.0.00 , Fan Spacer 80 Mm Cart Part No Dv0.029.17.0.00 , V Belt Cart Part No Dv0.029.18.0.Pr , Vbeltbx 1170 Ar Epdm Cart Part No Dv0.029.21.0.Pr , Fan Drive Asm: 3 Groove Pulley Cart Part No Dv0.029.210.0.00 , Fan Drive Asm3 Groove Pulley Cart Part No Dv0.029.220.0.Pr , Fan Drive Asm (3 Groove Pulley) Cart Part No Dv0.029.230.0.Pr , Fan Drive Asm Cart Part No Dv0.029.30.0.00 , Bearing Housing For Fan Drive Cart Part No Dv0.029.32.0.00 , Belt Bx 1170 Ar 2 Set Cart Part No Dv0.029.34.0.Pr , Damper Cart Part No Dv0.030.03.0.00 , Damper Cart Part No Dv0.030.09.0.00 , Timing Poinerfor Pulley Cart Part No Dv0.030.11.0.Pr , Angle Stripfor Tappet Fitting Cart Part No Dv0.030.12.0.Pr , Hose: Cac Cart Part No Dv0.031.03.0.00 , Breather Pipe Cart Part No Dv0.031.05.0.00 , Breather Hose Cart Part No Dv0.031.06.0.00 , Clip For Breather Pipe Cart Part No Dv0.031.21.0.00 , Radiator Fan (40) Cart Part No Dv0.031.24.0.00 , 44Fan For Dv10 Cart Part No Dv0.031.27.0.Pr , Radiator Cart Part No Dv0.031.30.0.00 , Radiator Pressure Cap Cart Part No Dv0.031.36.0.Pr , Radiator Assembly Dv0 031 39 0 Pr Cart Part No Dv0.031.39.0.Spr , Copper Radiator Assembly Cart Part No Dv0.031.45.0.Pr , Hose Heat Exchanger To Engine Pipe Cart Part No Dv0.031.51.0.00 , Hose For Cac To Heat Exchanger Pipe Cart Part No Dv0.031.52.0.00 , Pipe Thermostat To H E Cart Part No Dv0.031.54.0.00 , Suction Pipe (For Dv10) Cart Part No Dv0.031.56.0.00 , Joint For He Cart Part No Dv0.031.67.0.00 , Breather Hose Cart Part No Dv0.031.70.0.00 , Aluminium Radiator Assembly Cart Part No Dv0.031.78.0.Pr , Clamp Assembly For Water Outlet Pipe Cart Part No Dv0.031.80.0.00 , Aluminium Radiator Assembly Cart Part No Dv0.031.87.0.Pr , Aluminium Radiator Assembly Cart Part No Dv0.031.88.0.Pr , Hose For Raw Wtaerhe Cart Part No Dv0.031.97.0.Pr , Joint: Adaptor & Turbo Cart Part No Dv0.032.04.0.00 , Joint: Flange For T/C Lube Oil Outlet Pipe Cart Part No Dv0.032.06.0.00 , Flange With Adaptor (For Turbo Drain) Cart Part No Dv0.032.08.0.00 , Clamping Spacer Cart Part No Dv0.032.12.0.00 , Oil Supply Pipe L.H. Cart Part No Dv0.032.122.0.Pr , Oil Supply Pipe R.H. Cart Part No Dv0.032.123.0.Pr , Guard For Motor Cart Part No Dv0.032.124.0.Pr , Turbo Adaptor Cart Part No Dv0.032.18.0.00 , Turbo Adaptor Cart Part No Dv0.032.19.0.00 , Oil Supply Pipe L.H. : Modified Mfold (Crankcase To T/C In) Cart Part No Dv0.032.28.0.00 , Oil Supply Pipe R.H. : Modified Mfold (Crankcase To T/C In) Cart Part No Dv0.032.29.0.00 , Joint Cart Part No Dv0.032.33.0.00 , Turbo Adaptor (Lh From G.E.) Cart Part No Dv0.032.37.0.00 , Oil Supply Pipe Rh- Crank Case- Turbocharger Cart Part No Dv0.032.38.0.00 , Oil Supply Pipe L H From Crankacse To Turbocharger Cart Part No Dv0.032.39.0.00 , Turbo Drain Pipe Cart Part No Dv0.032.43.0.00 , Gasket For Turbocharger Cart Part No Dv0.032.45.0.Pr , Adaptorm30x1 5 X Both Sides Cart Part No Dv0.032.46.0.00 , Suction Pipe Engine To Radiator Cart Part No Dv0.032.73.0.00 , Breather Pipe Cart Part No Dv0.032.76.0.00 , Bracket For Breather Pipe Cart Part No Dv0.032.78.0.00 , Breather Hose Cart Part No Dv0.032.79.0.00 , Turbo Drain Pipe Cart Part No Dv0.032.82.0.Pr , Left Bank Tcharger: Dv10 Cart Part No Dv0.032.97.0.00 , Right Bank Tcharger: Dv10 Cart Part No Dv0.032.98.0.00 , Air Pipe Cart Part No Dv0.033.03.0.00 , Air Inlet Pipe From Cac Cart Part No Dv0.033.100.0.Pr , Support Bracket Cart Part No Dv0.033.104.0.Pr , Joint: Main Air Pipe Horizontal & Vertical Cart Part No Dv0.033.11.0.00 , Oring For Cac Pipe Cart Part No Dv0.033.116.0.Pr , Joint: Main Air Pipe And Ver Pipe Cart Part No Dv0.033.12.0.00 , Joint: Main Air Pipe Hor+Ver Cart Part No Dv0.033.13.0.00 , Joint: Bet Bend To Air Pipe Cart Part No Dv0.033.14.0.00 , Exhaust Elbow (Lhs From Fwe) Cart Part No Dv0.033.17.0.00 , Exhaust Elbow (Rhs From Fwe) Cart Part No Dv0.033.18.0.00 , Bracketfor Air Pipe Mounting Cart Part No Dv0.033.25.0.00 , Air Inlet Pipe T/C To Cac Cart Part No Dv0.033.26.0.00 , Joint For Air Inlet Pipe To Cac Cart Part No Dv0.033.27.0.00 , Air Inlet Pipe From Cac Cart Part No Dv0.033.28.0.00 , V Clamp: Turbo Cart Part No Dv0.033.33.0.00 , Turbo Compressor Out Pipe (Lhview From Fwe) Cart Part No Dv0.033.34.0.00 , Turbo Compressor Out Pipe (Rhview From Fwe) Cart Part No Dv0.033.35.0.00 , O Ring (For Compressor Out Pipe) Cart Part No Dv0.033.38.0.00 , Joining Plate Cart Part No Dv0.033.45.0.00 , Main Air Pipe (Horizontal Cac Inlet) Cart Part No Dv0.033.61.0.00 , Fuel Filter Bracket Cart Part No Dv0.033.63.0.00 , V-B& Clamp (88Mm Nominal Dia) Cart Part No Dv0.033.67.0.00 , Expansion Bellow: 6 Id Cart Part No Dv0.033.70.0.00 , Joint: Exhaust Bend And Expansion Bellow Cart Part No Dv0.033.73.0.00 , Joint: Extension Pipe And Exhaust Silencer Cart Part No Dv0.033.74.0.00 , Main Air Pipe (Horizontal Cac Out) Cart Part No Dv0.033.75.0.00 , V Band Clamp Cart Part No Dv0.033.79.0.Pr , Air Pipe Cart Part No Dv0.033.85.0.Pr , Cac Hose (Hot Side) Cart Part No Dv0.033.88.0.Pr , Radiator Fanrailway Application Cart Part No Dv0.033.90.0.Sp , Bracket (Air Inlet Pipe From Cac) Cart Part No Dv0.033.91.0.00 , Clamp For Air Inlet Pipe From Cac Cart Part No Dv0.033.92.0.00 , Rubber Sleeve For Air Inlet Pipe From Cac Cart Part No Dv0.033.94.0.Pr , Clamp For Air Inlet Pipe Tc To Cac Cart Part No Dv0.033.96.0.Pr , Clamp For Air Inlet Pipe Tc To Cac Cart Part No Dv0.033.97.0.Pr , Rubber Sleeve For Air Inlet Pipe T C To Cac Cart Part No Dv0.033.98.0.Pr , Air Inlet Pipe T C To Cac Cart Part No Dv0.033.99.0.Pr , Engine Mtd. Foot Cart Part No Dv0.034.13.0.00 , Hose Reducer Elbow: Dv10 Cart Part No Dv0.035.04.0.00 , Hose: Reducer Elbow Cart Part No Dv0.035.08.0.00 , Pipe Assembly Powder Coated (Dv8/Dv10) Cart Part No Dv0.035.13.0.00 , Fan Guard For Radiator Dv0.031.88.0.Pr Cart Part No Dv0.037.10.0.Sp , Feed Pump Cart Part No Dv0.040.01.0.00 , Drive End Bearing Cart Part No Dv0.040.04.0.00 , Governer End Bearing Cart Part No Dv0.040.05.0.00 , Intermediate Support Bearing For Cam Shaft Cart Part No Dv0.040.06.0.00 , Oil Seal For Drive End Cart Part No Dv0.040.07.0.00 , Oil Seal Housing Cart Part No Dv0.040.08.0.00 , O Ring: Oil Seal Housing Cart Part No Dv0.040.09.0.00 , Fuel Pumpcam Box Type Cart Part No Dv0.040.10.0.00 , Locking Nut For Gear Mounting Flange Cart Part No Dv0.040.11.0.00 , Gear Mounting Flangehub Cart Part No Dv0.040.115.0.00 , Flat Seal For Oil Seal Housing Cart Part No Dv0.040.116.0.00 , Cam Shaft Cart Part No Dv0.040.117.0.00 , Governor Mounting Plate Cart Part No Dv0.040.14.0.00 , Fuel Pumpcam Box Type Cart Part No Dv0.040.140.0.Pr , Non Return Valve (1.4 Bar) Cart Part No Dv0.040.157.0.Pr , End Support Bush For Rack Cart Part No Dv0.040.21.0.00 , Rack Support Adj. Screw Cart Part No Dv0.040.23.0.00 , Dome Nut For Rack Support Cart Part No Dv0.040.24.0.00 , Locking Screw For Rack Cart Part No Dv0.040.25.0.00 , Pf33 Individual Pump Cart Part No Dv0.040.27.0.00 , Roller Tappet Assly. Cart Part No Dv0.040.30.0.00 , Pf 33 Pump Mounting Flange Cart Part No Dv0.040.36.0.00 , Plugs For Oil Gallery Cross Holes Cart Part No Dv0.040.44.0.00 , Core Plug For Fuel Pump (Bottom Side) Cart Part No Dv0.040.48.0.00 , Cap Nut For Rack Driving Side Cart Part No Dv0.040.49.0.00 , Stud For Pump Mounting Cart Part No Dv0.040.53.0.00 , Fuel Pumpcam Box Type Cart Part No Dv0.040.540.0.Pr , Line Hand Primer Cart Part No Dv0.040.56.0.00 , Core Plug For Fuel Gallery Cart Part No Dv0.040.57.0.00 , Breather Screw Cart Part No Dv0.040.58.0.00 , Vent For Breather Screw Cart Part No Dv0.040.59.0.00 , Lock For End Support Bush Cart Part No Dv0.040.61.0.00 , Washer For Fip Mounting Cart Part No Dv0.040.63.0.00 , Spherical Washer: Fip Mtg Cart Part No Dv0.040.64.0.00 , Shim For Camshaft End Play (0.5Mm Thick) Cart Part No Dv0.040.65.0.00 , Shim For Roller Tapet(2.5Mm Thick) Cart Part No Dv0.040.66.0.00 , Shim For Roller Tappet (2.6Mm) Cart Part No Dv0.040.67.0.00 , Shim For Roller Tappet (2.7Mm Thick Cart Part No Dv0.040.68.0.00 , Shim For Camshaft Endplay(1.00Mm Thick) Cart Part No Dv0.040.69.0.00 , Dome Nut For Rack Locking Screw Cart Part No Dv0.040.71.0.00 , Shim For Roller Tappet (2.8Mm Thick) Cart Part No Dv0.040.74.0.00 , Shim For Roller Tappet (2.9Mm Thick) Cart Part No Dv0.040.75.0.00 , Banjo Bolt For Fip Oil Supply M8 X 1 25 Cart Part No Dv0.040.81.0.00 , Washer For Cap Nut Cart Part No Dv0.040.82.0.00 , Linkage Assembly For Governor Cart Part No Dv0.040.85.0.00 , Helicoil (M14x15x14 Mm Long) Cart Part No Dv0.040.91.0.00 , Speed Control Unit Cart Part No Dv0.040.92.0.00 , Actuator: 24V Cart Part No Dv0.040.93.0.00 , Joint: Governor Mounting Plate Cart Part No Dv0.040.98.0.00 , Joint: Centrifugal Adaptor & Filter Cart Part No Dv0.041.04.0.00 , Gasket: Oil Sump And Centrifuge Adaptor Cart Part No Dv0.041.07.0.00 , Adaptor For Centrifuge Filter Cart Part No Dv0.041.15.0.00 , Oil Filling Pipe Cart Part No Dv0.041.16.0.00 , O-Ring For Oil Filling Pipe Cart Part No Dv0.041.17.0.00 , Centrifuge Mtg.Assly Cart Part No Dv0.041.20.0.00 , Centrifugal Oil Cleaner (Band Design) Cart Part No Dv0.041.25.0.00 , Centrifuge Adaptor Cart Part No Dv0.041.42.0.00 , Oil Inlet Pipefrom Crankcase To Centrifuge Filter Cart Part No Dv0.041.46.0.00 , Joint: Delivery Tube Flange Cart Part No Dv0.042.03.0.00 , O Ring Dia 36: L.O. Delivery Tube Cart Part No Dv0.042.05.0.00 , Clamp (For Oil Delivery Tube) Cart Part No Dv0.042.07.0.00 , Strap Cart Part No Dv0.042.08.0.00 , Rubber Bush Cart Part No Dv0.042.09.0.00 , Delivery Tube Cart Part No Dv0.042.10.0.00 , Joint: Suction Tube Flange Cart Part No Dv0.043.05.0.00 , Suction Tubesub Assly Cart Part No Dv0.043.10.0.00 , Dowel Bush For Alternator Mounting Bracket Cart Part No Dv0.044.04.0.00 , Alternator Pulley Cart Part No Dv0.044.08.0.00 , Stud: Alternator Cart Part No Dv0.044.11.0.00 , Swivel Piece Cart Part No Dv0.044.12.0.00 , Eye Bolt: Alternator Cart Part No Dv0.044.13.0.00 , Charging Alternator Bracket Cart Part No Dv0.044.14.0.00 , Dowel Bolt: Alternator Cart Part No Dv0.044.15.0.00 , Counter Shunk Head Screw-Dv Injector Leakoff Cart Part No Dv0.045.03.0.00 , Clamp Assembly For Leak Off Pipe & Hppipe Cart Part No Dv0.045.30.0.00 , Breather Plate Cart Part No Dv0.046.01.0.00 , Breather Adaptor Cart Part No Dv0.046.02.0.00 , O Ring: Breather Plate Cart Part No Dv0.046.03.0.00 , Joint: Breather Plate & Adapter Cart Part No Dv0.046.04.0.00 , Crankcase Breather Cart Part No Dv0.046.07.0.00 , O Ring Cart Part No Dv0.046.09.0.00 , Hose: Radiator To Engine Cart Part No Dv0.048.02.0.00 , Heat Shield (R.H) Cart Part No Dv0.051.16.0.00 , Heat Shield (L.H) Cart Part No Dv0.051.17.0.00 , Upper Heat Shield Lh From Fwe Cart Part No Dv0.051.51.0.Pr , Lower Heat Shield Lh From Fwe Cart Part No Dv0.051.53.0.Pr , Upper Heat Shield Rh From Fwe Cart Part No Dv0.051.54.0.Pr , Lower Heat Shield Rh From Fwe Cart Part No Dv0.051.55.0.Pr , End Cover For Heat Shieldl Hfrom Fwe Cart Part No Dv0.051.56.0.Pr , End Cover For Heat Shieldr Hfrom Fwe Cart Part No Dv0.051.57.0.Pr , Heat Shield Sub Assemblyrh Side From Fwe End Cart Part No Dv0.051.60.0.Pr , Bracket-1 (For Heat Shield Mtg.) Cart Part No Dv0.051.63.0.Pr , Bracket-2 (For Heat Shield Mtg.) Cart Part No Dv0.051.64.0.Pr , Bracket-3 (For Heat Shield Mtg.) Cart Part No Dv0.051.65.0.Pr , Bracket (For Heat Shield Cover Mtg.) Cart Part No Dv0.051.66.0.Pr , Heat Shield Coverl Hside From Fwe Cart Part No Dv0.051.67.0.Pr , Heat Shield Coverr Hside From Fwe Cart Part No Dv0.051.68.0.Pr , Heat Sub Assemblylh Side From Fwe End Cart Part No Dv0.051.70.0.Pr , Spinon Preline Filter Ctg Cart Part No Dv0.053.05.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.01.0.00 , Anti Vibration Mount Pgs-3(N1)B Cart Part No Dv0.061.03.0.00 , Anti Vibration Mount Pgs 3800N1 Cart Part No Dv0.061.07.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.15.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.16.0.00 , Anti Vibration Mounts Cart Part No Dv0.061.17.0.00 , Avm For 500Kva Rdso Projectgf B 70 Cart Part No Dv0.061.18.0.Pr , Joint: Dv10 Turbo Cart Part No Dv0.064.01.0.00 , Fuel Pipe Adaptor Cart Part No Dv0.069.04.0.00 , Adaptorfor Fuel Inlet Cart Part No Dv0.069.08.0.00 , Adaptor Cart Part No Dv0.069.47.0.00 , Oil Drain Pipe (Fip To Crank Case) Cart Part No Dv0.069.65.0.00 , Leak Off Pipe Cart Part No Dv0.069.85.0.00 , Vent Pipe Cart Part No Dv0.071.01.0.00 , Elbow Connection Cart Part No Dv0.071.02.0.00 , Vent Pipe For Radiator-750 Kva Cart Part No Dv0.071.03.0.00 , Common Rail Fuel Pump Gear Cart Part No Dv0.072.06.0.Pr , Common Rail Fuel Pump Assembly Cart Part No Dv0.072.60.0.00 , Joint For Barring Device Cart Part No Dv0.074.09.0.00 , Plastic Capwater Inlet Cart Part No Dv0.075.01.0.00 , Plastic Capcac Outlet Cart Part No Dv0.075.06.0.00 , Plastic Capcap Inlet Cart Part No Dv0.075.07.0.00 , Protection Plastic Capforintake Adaptor Cart Part No Dv0.075.15.0.Pr , Fan Clutch Asembly For Dv10 12 Cart Part No Dv0.076.40.0.00 , Flywheel Housing Cart Part No Dv0.086.16.0.00 , Hosebetinlet Manifold Cac Adaptor R H Cart Part No Dv0.086.37.0.00 , Cover For Gear Casing Cart Part No Dv0.086.39.0.00 , Sparkplug For Dv0 Gas Engine Cart Part No Dv0.087.30.0.Pr , Electronic Throttle Body F Tech Cart Part No Dv0.087.50.0.Pr , Ignition Coil For Dv Gas Engines Cart Part No Dv0.087.52.0.Pr , Uego Sensor For Gas Engines Cart Part No Dv0.087.53.0.Pr , Wiring Harness Boxlhs From Fwe Cart Part No Dv0.099.75.0.Pr , Wiring Harness Boxrhs From Fwe Cart Part No Dv0.099.77.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Iv Dcu 1 Chamber 1 Cart Part No Dv0.112.10.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Iv Dcu 1 Chamber 2 Cart Part No Dv0.112.20.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 1 Cart Part No Dv0.114.10.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 5/6/7 Cart Part No Dv0.114.30.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 8 Cart Part No Dv0.114.40.0.Pr , Dcu Connection Wiring Harness For Dv10 Engine Cpcb 4 Cart Part No Dv0.114.50.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv0.114.60.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb 4 Engineecu Chamber 1 Cart Part No Dv0.114.70.0.Pr , Radiator Drain Pipe For Dv Cart Part No Dv0.153.01.0.00 , Genset Kit (Rdso Power Car) Cart Part No Dv0.15Pk.01.0.00 , Silencer Assembly Cart Part No Dv0.188.20.0.00 , Ecuepc 1830 31 Md1ce200 Cart Part No Dv0.1999.01.0.Pr , Metallic Pipe Engine To Egtrhs Side From F W E Cart Part No Dv0.477.44.0.Pr , Hydraulic Pipe From Engine Out To Dosi Cart Part No Dv0.477.47.0.Pr , Hydraulic Pipe From Supply Module Out Cart Part No Dv0.477.49.0.Pr , Hydraulic Pipe From Supply Module Out Cart Part No Dv0.477.52.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-3) (Lhs Egt F.W.E.) Cart Part No Dv0.478.01.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-4) (Rhs Egt F.W.E.) Cart Part No Dv0.478.02.0.Pr , Hose Clamp Cart Part No Dv0.505.02.0.00 , Support For Air Cleaner Pipe Cart Part No Dv0.505.07.0.00 , Air Pipe Cart Part No Dv0.505.18.0.00 , Air Cleaner Kit Lh Cart Part No Dv0.505.30.0.00 , Air Cleaner Kit Rh Cart Part No Dv0.505.40.0.00 , Primary Element -Air Cart Part No Dv0.505.41.0.Pr , Air Filter Safety Cart Part No Dv0.505.42.0.Pr , Rubber Sleeve Cart Part No Dv0.506.01.0.00 , Air Cleaner Assembly For 500Kva Rdso Projectmcf Cart Part No Dv0.506.115.0.Pr , Air Cleaner Assembly ( L.H Side ) Cart Part No Dv0.506.30.0.00 , Air Cleaner Assembly ( R.H Side ) Cart Part No Dv0.506.40.0.00 , Fuel Pipe: Fuel Tank To Leak Off Pipe Cart Part No Dv0.507.02.0.00 , Fuel Pipe Fuel Tank -Fuel Filter Cart Part No Dv0.507.03.0.00 , Adaptor (M22 X 15- M18 X 15) Cart Part No Dv0.507.04.0.00 , Fuel Pipe - Pre Filter -Fip Cart Part No Dv0.507.15.0.00 , Adaptor (M8 X125 - M27 X 15) Cart Part No Dv0.507.19.0.00 , Inlet & Outlet Connection Cart Part No Dv0.507.25.0.00 , Fuel Pipe From Pre Filter To Feed Pump Cart Part No Dv0.507.34.0.Pr , Fuel Pipe Return Cart Part No Dv0.507.81.0.Pr , Fuel Pipe (From Tank To Pre Filter) Cart Part No Dv0.507.82.0.Pr , 24V55a Charging Alternator Cart Part No Dv0.639.01.0.Pr , Koel Green Alternatorkg500 S T Framel Kg 47 2 M7sae 1 14 415V50 Hz0 8 Pf Cart Part No Dv0.801.15.0.00 , 500 Kva750v Ac50hz3 Phase4 Wirelong Coupledframe Lstr 472 L Alternator F Cart Part No Dv0.801.33.0.Pr , Over Voltage Protection Unit Cart Part No Dv0.801.37.0.Sp , Fuel Level Sensor 225Mm Cart Part No Dv0.802.15.0.00 , Fuel Level Sensor 227Mm Cart Part No Dv0.802.25.0.00 , Fuel Level Sensor- 220Mm Height Cart Part No Dv0.802.35.0.00 , Fuel Transducersmart Cap 225 Eth Cart Part No Dv0.802.45.0.Pr , 4-20Ma Pressure Sensor Cart Part No Dv0.802.52.0.Pr , Drain Pipe For 500 Kva Rdso Project Cart Part No Dv0.806.89.0.Pr , Drain Pipe From Sump To Pump 500 Kva Rdso Project Cart Part No Dv0.806.91.0.Pr , Breather Hose For 500 Kva Rdso Project Cart Part No Dv0.806.93.0.Pr , Kent Oil Meter15mm Cart Part No Dv0.806.96.0.Pr , Bracket For Water Pipe Clamping Cart Part No Dv0.806.99.0.Pr , Belt Guard Cart Part No Dv0.807.02.0.Pr , Avm Of Radiator For 500Kva Rdso Project Cart Part No Dv0.807.03.0.Pr , Dse 2133 Rtd Thermocouple Input Expansion Module Cart Part No Dv0.807.111.0.00 , Cac Out Pipe Clamp Cart Part No Dv0.807.115.0.Pr , Coolant Pipe Support Bracket Assembly Cart Part No Dv0.807.116.0.Pr , Electromagnetic Vacuum Indicator Emviwith Connector Cart Part No Dv0.807.19.0.Pr , Matchweld Couplings Dia 76 1 Cart Part No Dv0.807.21.0.Pr , U Clamp For Fuel Flow Meter Clamping Cart Part No Dv0.807.24.0.Pr , Flexible Coupling Vulkon Cart Part No Dv0.807.26.0.Pr , Tubular Lead Acid Battery8v290ahrdso Approved Is7624 Compliant Cart Part No Dv0.807.34.0.Pr , U Clamp For Water Pipe Claming (Dia.76.1) Cart Part No Dv0.807.38.0.Pr , Adaptor For Vent Connection For 500 Kva Rdso Cart Part No Dv0.807.47.0.Pr , Air Flow Paddle Switch Cart Part No Dv0.807.48.0.Pr , Float Type Level Sensorthreadingeffective Length 90 Mm Cart Part No Dv0.807.52.0.Pr , Ventilation Blower Assembly Complete With Fan Motor Housing Brackets Suit Cart Part No Dv0.807.72.0.Pr , Roof Top Air Filter With Louverconfig 1X1 Cart Part No Dv0.807.89.0.Pr , Junction Box For Fuel Return Pipes Cart Part No Dv0.807.98.0.Pr , Exhaust Pipe Support Assembly Cart Part No Dv0.808.102.0.Pr , Suction Pipe Cart Part No Dv0.808.111.0.Pr , Coolant Pipe From Thermostst To Radiator India 76 2Mm Cart Part No Dv0.808.112.0.Pr , Air Inlet Pipe From Radiator Outlet To Engine In Cart Part No Dv0.808.114.0.Pr , Support Bracket For Radiator Cac Pipe Clamping Cart Part No Dv0.808.115.0.Pr , Flexible Air Vent Pipe Cart Part No Dv0.808.117.0.Pr , U Clamp For Cac Pipe Support Cart Part No Dv0.808.118.0.Pr , Heat Shield For Primary Silencer Cart Part No Dv0.808.128.0.Pr , Heat Shield For Secondary Silencer Cart Part No Dv0.808.129.0.Pr , Exhaust Gasket Cart Part No Dv0.808.132.0.Pr , Bracket For Fuel Water Seperator Mounting Cart Part No Dv0.808.141.0.Pr , Cover For Fuel Pipes At Starter Side Cart Part No Dv0.808.143.0.Pr , Flexible Inlet Fuel Pipe From Filter Outlet To Engine Inlet Cart Part No Dv0.808.144.0.Pr , Flexible Inlet Fuel Pipe 1 From Filter Outlet To Engine Inlet Cart Part No Dv0.808.145.0.Pr , Metallic Inlet Fuel Pipe From Filter Outlet To Engine Inlet Cart Part No Dv0.808.146.0.Pr , Metallic Inlet Fuel Pipe-1 From Filter Outlet To Engine Inlet Cart Part No Dv0.808.147.0.Pr , Adaptor M16x1 5M Sealxm22x1 5 M Cart Part No Dv0.808.148.0.Pr , Fuel Pipe From Flow Meter Outlet To Filter Inlet Cart Part No Dv0.808.149.0.Pr , Fuel Return Pipe From Tee To Flow Meter Cart Part No Dv0.808.152.0.Pr , Tube Clampsfor 2 Tubes Cart Part No Dv0.808.154.0.Pr , Tube Clampsfor 1 Tube Cart Part No Dv0.808.155.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.156.0.Pr , Union Adaptorm22x1 5 X M22x1 5 Cart Part No Dv0.808.157.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.159.0.Pr , Flexible Inlet Fuel Pipe From Water Seperator To Flow Meter Cart Part No Dv0.808.161.0.Pr , Flexible Inlet Fuel Pipe From Water Seperator To Flow Meter Cart Part No Dv0.808.163.0.Pr , Metallic Return Fuel Pipe From Flow Meter To Coach Tank Cart Part No Dv0.808.164.0.Pr , Flexible Return Fuel Pipe From Flow Meter To Coach Tank Cart Part No Dv0.808.165.0.Pr , Metallic Inlet Fuel Pipe From Coach Tank To Water Seperator Cart Part No Dv0.808.166.0.Pr , Tee Connectionm22x1 5 F Xm22x1 5 M Xm22x1 5 M Cart Part No Dv0.808.167.0.Pr , Bracket For Fuel Filter Mounting Cart Part No Dv0.808.168.0.Pr , Adaptor M22x1 5M Sealxm22x1 5 M Cart Part No Dv0.808.171.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.172.0.Pr , Adaptor Reducer M22x1 5 M Xm16x1 5 M Cart Part No Dv0.808.176.0.Pr , Adaptor Reducer M22x1 5 F X1 8Npt F Cart Part No Dv0.808.182.0.Pr , Cover For Fuel Pipes At Alternator Back Side Cart Part No Dv0.808.183.0.Pr , Hose For Air Cleaner Cart Part No Dv0.808.198.0.Pr , Adaptor - M30x2(M)X 1 B.S.P(F) Cart Part No Dv0.808.205.0.Pr , Hose Clamp T Bolt Cart Part No Dv0.808.208.0.Pr , Adaptor M22x1 5 Mx 1 B S Pf Cart Part No Dv0.808.212.0.Pr , Clamp For Engine Harness Cart Part No Dv0.808.216.0.Pr , Tray For Fuel Collector Cart Part No Dv0.808.217.0.Pr , Metallic Inlet Pipe From Flow Meter To Pump Cart Part No Dv0.808.221.0.Pr , Bracket For Pump Cart Part No Dv0.808.222.0.Pr , Tube Clamps Platefor Rbp215x Cart Part No Dv0.808.223.0.Pr , Digital Fuel Flow Meter Cart Part No Dv0.808.224.0.Pr , Bracket For Digital Fuel Flow Meter Cart Part No Dv0.808.225.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.226.0.Pr , Return Fuel Pipe From Engine Outlet To Flow Meter Cart Part No Dv0.808.227.0.Pr , Metallic Inlet Fuel Pipe From Water Seperator To Flow Meter Cart Part No Dv0.808.228.0.Pr , Bracket For Fuel Pipe Support Cart Part No Dv0.808.229.0.Pr , Support Bracket 1 For Air Suction Pipe Cart Part No Dv0.808.232.0.Pr , Support Bracket 2 For Air Suction Pipe Cart Part No Dv0.808.233.0.Pr , Flexible Vent Pipe For 500Kva Rdso Project Cart Part No Dv0.808.25.0.Pr , Y Pipe Mounting Bracket Cart Part No Dv0.808.256.0.Pr , Air Suction Pipe Cart Part No Dv0.808.266.0.Pr , Clamp For Water Piping Support Cart Part No Dv0.808.27.0.Pr , Support Plate For Radiator Cac Hose Cart Part No Dv0.808.29.0.Pr , Joint For Exhaust Junction Box Cart Part No Dv0.808.32.0.Pr , Joint For Air Suction Junction Box Cart Part No Dv0.808.34.0.Pr , Hose For Air Suction Pipe Cart Part No Dv0.808.36.0.Pr , Clamp For Reducer Hose Cart Part No Dv0.808.37.0.Pr , Adaptor For Lube Oil Temp Sensor Cart Part No Dv0.808.39.0.00 , Adaptor For Fuel Inlet And Return Pipe On Coach Piping Cart Part No Dv0.808.41.0.Pr , U Clamp For Cac Pipe Cart Part No Dv0.808.51.0.Pr , Joint For Air Suctionmounting On Caoch Cart Part No Dv0.808.59.0.Pr , Coolant Pipe From Thermostst To Radiator In Cart Part No Dv0.808.64.0.Pr , Suction Pipe Cart Part No Dv0.808.66.0.Pr , Coolant Pipe From Thermostst To Radiator India 76 2Mm Cart Part No Dv0.808.67.0.Pr , Expansion Bellow Cart Part No Dv0.808.78.0.Pr , Hose For Air Suction Pipe Cart Part No Dv0.808.82.0.Pr , Support Bracket For Exhaust Junction Box Cart Part No Dv0.808.83.0.Pr , Hose Clip T Bolt Type Cart Part No Dv0.808.84.0.Pr , Shim 0 1Mm Cart Part No Dv0.808.93.0.Pr , Shim 0 2Mm Cart Part No Dv0.808.94.0.Pr , Shim 0 5Mm Cart Part No Dv0.808.95.0.Pr , Shim 1 0Mm Cart Part No Dv0.808.96.0.Pr , Shim 2 0Mm Cart Part No Dv0.808.97.0.Pr , Accessories For Pump Flow Meter & Fuel Filter Mounting Cart Part No Dv0.809.18.0.00 , Accessories For Water Seperator Mounting Cart Part No Dv0.809.19.0.00 , Side Wall Air Filter With Louverconfig 3X3 Filters Cart Part No Dv0.809.73.0.Pr , Coolent Level Switch Cart Part No Dv0.812.22.0.Pr , Air Inlet Hose For 101 6 Od Cart Part No Dv0.821.12.0.Pr , Support Plate Cart Part No Dv0.821.15.0.Pr , Vent Pipe 3000Mm Cart Part No Dv0.822.41.0.Pr , Couplings Dia 127 For Cac Cart Part No Dv0.823.12.0.Pr , Door Visor For Dv Series Canopy Cart Part No Dv0.831.16.0.Pr , 1500 Hrs C Check Maintenance Kit Dv0 8501 C4 Dv0 8552 C4 Cart Part No Dv0.850.01.0.Sp , Relay Board 1.5 Ch 70 A Capa Cart Part No Dv0.853.07.0.00 , Relay Board 4 Channel Cart Part No Dv0.853.12.0.00 , Avr To Panel Wiring Harness Cart Part No Dv0.853.41.0.Pr , Communication Cable And Usb Converter Cable Cart Part No Dv0.853.45.0.Pr , Avr Harness For A Bank Cart Part No Dv0.853.46.0.Pr , Avr Harness For B Bank Cart Part No Dv0.853.47.0.Pr , Connector For Panel Side Cart Part No Dv0.853.50.0.00 , Connector For Panel Side Cart Part No Dv0.853.60.0.00 , Relay Board 24V Dc 2 Ch 2C/O Cart Part No Dv0.854.09.0.00 , Assembly For Krm Unit For Kg1500 With Pakage Cart Part No Dv0.858.01.0.Pr , Genset Controller 7320 Mk Ii Cart Part No Dv0.858.05.0.00 , Kg1500 Synchronization Controller Model No 8440 2219 Cart Part No Dv0.858.06.0.Pr , Engine Control Panel Assembly With Easy Gen 2500 Controller Cart Part No Dv0.859.10.0.Pr , Fresh Air In Temprature Sensortypertd Cart Part No Dv0.861.12.0.Pr , Dg Compartment Coach Temptemprature Sensortypertd Cart Part No Dv0.861.13.0.Pr , Exhaust Temperature Sensork Thermocouple Cart Part No Dv0.861.14.0.Pr , 24V 2.5Amp Trickle Charger Cart Part No Dv0.861.31.0.00 , Avr Model Tavr 60 Cart Part No Dv0.862.36.0.00 , P.T. 800/415 V5va Class -1 Cart Part No Dv0.868.07.0.00 , Genset Control Panel Assembly With Kg 745 Unit Cart Part No Dv0.868.10.0.Pr , Pc Engine P1bcheck Kit Dv0 9019Dv0 9021Dv0 9027 Cart Part No Dv0.900.01.0.Sp , Float Level Sensor Cart Part No Dv0.901.11.0.00 , Float Type Level Sensor Cart Part No Dv0.901.25.0.00 , Float Type Level Sensor Cart Part No Dv0.901.26.0.00 , Float Level Sensor 105 Len Cart Part No Dv0.901.29.0.00 , Wet Pm Kit (W/O Oil) - For Dv0.9018 Cart Part No Dv0.901.8.0.Sp , Pc Engine P1bcheck Kit Phase Ii Dv0 9026 Cart Part No Dv0.902.01.0.Sp , Float Type Level Sensorthreading1bspeffective Length 137 Mm Cart Part No Dv0.902.50.0.Pr , Pc Engineccheck Kitdv0 9019 9021 Cart Part No Dv0.903.01.0.Sp , Pc Engineccheck Kitdv0 9027 Cart Part No Dv0.904.01.0.Sp , Pc Engineccheck Kitdv0 9026 Cart Part No Dv0.905.01.0.Sp , Battery Cable Assembly70 Sq.Mm Cart Part No Dv0.907.10.0.00 , Engine Wiring Harness Assly: Dv0 Cart Part No Dv0.910.20.0.00 , Engine Wiring Harness Assembly With Kg545 Cart Part No Dv0.910.50.0.00 , Engine Wiring Harness Assembly:Dv10 Engine With Kg545 Unit & 4-20 Ma Gems Lop Se Cart Part No Dv0.910.60.0.00 , Engine Wiring Harness Sf Dv10 Engine Cart Part No Dv0.910.90.0.00 , Engine Control Panel To Alternator Control Harness Cart Part No Dv0.911.20.0.00 , Engine Control Panel To Alternator Control Harness Assemblyfor C T 3Phsu Cart Part No Dv0.911.40.0.00 , Engine Control Panel To Alternator Controlharness Assemblyfor C T3 Phsu Cart Part No Dv0.911.70.0.00 , Engine Wiring Harness With Dse 7320 Mkii Unit For Dv10 With Air Shutoff Valve Cart Part No Dv0.913.40.0.Pr , Engine Wiring Harness Assembly For Dv10 Enginewith Ncv Conduitt Cart Part No Dv0.918.70.0.Pr , Genset Panel To Remote Panel Harness Cart Part No Dv0.921.10.0.Pr , Engine Control Alternator C T Harness Cart Part No Dv0.921.20.0.Pr , Remote Panel To Railway Main Panel Harness Cart Part No Dv0.921.30.0.Pr , 3 3 K Ohm Parallel Resistor Module Cart Part No Dv0.921.70.0.Pr , Engine Wiring Harness Assembly For Dv10 Engine( With Ncv Conduitt ) Sf Isolatio Cart Part No Dv0.923.40.0.Pr , Liner Removing And Placing Tool Cart Part No Dv0.950.04.0.00 , Liner Pressing Mandrel Assembly Cart Part No Dv0.950.05.0.00 , Collet Fitting Tool Cart Part No Dv0.950.505.0.00 , Stem Seal Fitting Tool Cart Part No Dv0.950.506.0.00 , Injector Removing Tool Cart Part No Dv0.950.507.0.00 , Guide Stud For Crank Pulley Cart Part No Dv0.950.523.0.00 , Guide Stud For Flywheel Cart Part No Dv0.950.525.0.00 , Tool For Push Rod Spring Compression Cart Part No Dv0.950.530.0.00 , Guide Sleeve For Piston Insertion In To Liner For Dv Cart Part No Dv0.950.571.0.Tol , Guide Sleeve For Piston Insertion In To Liner For Crdi Cart Part No Dv0.950.572.0.Tol , Oil Seal Housing Alignment Toolflywheel End Side Dv0 950 69 0 00 Cart Part No Dv0.950.69.0.Tol , Oil Seal Housing Alignment Toolpulley End Side Dv0 950 70 0 00 Cart Part No Dv0.950.70.0.Tol , Oil Seal Pressing Tool For Pulley End Side For Dv Seriesdv0 950 72 0 00 Cart Part No Dv0.950.72.0.Tol , Plate Type Heat Exchanger (320-400Kva) Cart Part No Dv0.992.01.0.Pr , Turbo Compressor Pipe Out R H Cacside Cart Part No Dv0.992.28.0.Pr , Avr Sd-02 Cart Part No Dv0.998.01.0.Sp , Compounding Transformer Cart Part No Dv0.998.02.0.Sp , Variable Resistor Cart Part No Dv0.998.05.0.Sp , Relay K1 Cart Part No Dv0.998.08.0.Sp , Relay K2 Cart Part No Dv0.998.09.0.Sp , Varistor Cart Part No Dv0.998.11.0.Sp , Metring Ct Assembly Cart Part No Dv0.998.13.0.Sp , Diode Assembly Cart Part No Dv0.998.16.0.Sp , Metering Ct Neutral Cart Part No Dv0.998.17.0.Sp , Fuse F1 Cart Part No Dv0.998.19.0.Sp , Bridge Rectifier Diode Cart Part No Dv0.998.20.0.Sp , Contactor (K3) 24V Cart Part No Dv0.998.23.0.Sp , Fuse F2 Cart Part No Dv0.998.24.0.Sp , Pc Engine P1/B Check Kit - Dv0.9019, Dv0.9021, Dv0.9027 Woo Cart Part No Dv0.998.25.0.Sp , Pc Engine P1/B Check Kit Phase Ii - Dv0.9026 Woo Cart Part No Dv0.998.26.0.Sp , Pc Engine C Check Kit - Dv0.9019, Dv0.9021 Woo Cart Part No Dv0.998.27.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9027 Woo Cart Part No Dv0.998.28.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9026 Woo Cart Part No Dv0.998.29.0.Sp , Pc Engine Add On Kit Phase I Cart Part No Dv0.998.30.0.Sp , Pc Engine Add On Kitphase Ii Cart Part No Dv0.998.31.0.Sp , Dv0.998.36.* Cart Part No Dv0.998.36.0.Sp , Ct Assembly For Rdso 500Kva Vave (Suitable For Alternator) Cart Part No Dv0.998.51.0.Pr , Dv Service Timing Tool Cart Part No Dv0.999.01.0.Tol , Avr Excitation Unit Cart Part No Dv0.999.05.0.Sp , Compounding Transformer Cart Part No Dv0.999.07.0.Sp , Wet Pm Kit (W/O Oil ) For Dv0.9076 Cart Part No Dv0.999.102.0.Sp , Exciter Rotor Cart Part No Dv0.999.28.0.Sp , Exciter Stator Cart Part No Dv0.999.33.0.Sp , Centrifugal Filter Service Kit For Dv Cart Part No Dv0.999.40.0.00 , Motor 3Ph (Ie2 Type) V 415D (+/-10%), 50Hz(+/-5%), R/Min 1460, 22Kw, 30Hp, 42A, Cart Part No Dv0.999.40.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.1045... - Dv10 Cart Part No Dv0.999.71.0.Sp , Induction Motor5kw6 7 Hp 3 Phase50 Hz Cart Part No Dv0.999.73.0.Sp , Wet Pm Kit (W/O Oil) Fordv0.8107 - Dv10ta G1 Cart Part No Dv0.999.83.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.9026... - Dv10ta G1 Cart Part No Dv0.999.84.0.Sp , Battery Tester Cart Part No Dv0.999.85.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.1002 - Dv10 Cart Part No Dv0.999.87.0.Sp , Radiator U Hose Cart Part No Dv0.999.88.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.9013, Dv0.8101, Dv0.9009 - Dv10ta Cart Part No Dv0.999.89.0.Sp , Wet Pm Kit (W/O Oil) For Dv0.9019 - Dv10ta Cart Part No Dv0.999.90.0.Sp , Pc Engine P1/B Check Kit - Dv0.9019, Dv0.9021, Dv0.9027 Wo Cart Part No Dv0.999.91.0.Sp , Pc Engine P1/B Check Kit Phase Ii - Dv0.9026 Wo Cart Part No Dv0.999.92.0.Sp , Pc Engine C Check Kit - Dv0.9019, Dv0.9021 Wo Cart Part No Dv0.999.93.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9027 Wo Cart Part No Dv0.999.94.0.Sp , Pc Engine C Check Kit Phase Ii - Dv0.9026 Wo Cart Part No Dv0.999.95.0.Sp , Pc Engine Tappet Setting Kit Cart Part No Dv0.999.96.0.Sp , Pc Engine Tappet Setting Kit Phase Ii Cart Part No Dv0.999.97.0.Sp , Dcuvd1cc01 Cart Part No Dv0.Egt4.01.0.Pr , Expansion Tank Cart Part No Dv0.M001.06.0.00 , Crankcase Assembly Cart Part No Dv2.001.30.0.00 , Cylinder Liner Assemblywith Abp Ring Cart Part No Dv2.002.20.0.Pr , Crankshaft Assly Without Gear Cart Part No Dv2.003.10.0.00 , Crank Pulley 200 Pcd & Spb Profile Cart Part No Dv2.003.13.0.00 , Extension Pulley For Fan Drive (Pcd 176) (6 Groove) Cart Part No Dv2.003.16.0.00 , Extension Pulley For Fan Drivepcd 176 6 Groove Cart Part No Dv2.003.18.0.Pr , Piston Assembly Cart Part No Dv2.006.10.0.Spr , Piston Ring Set Cart Part No Dv2.006.20.0.Spr , Nozzle Clampfinish Cart Part No Dv2.007.04.0.00 , Cylinder Head Sub Assembly With Valve Spring Valve For Cr Cart Part No Dv2.007.130.0.00 , Cylinder Head Assembly Complete For Cr Cart Part No Dv2.007.150.0.Pr , Oil Cooler17 Plate Pn Nj 57000For Dv Engine Cart Part No Dv2.014.06.0.00 , Filter Header Cart Part No Dv2.014.07.0.00 , Hose: Radiator To Suction Pipe Cart Part No Dv2.014.24.0.00 , Jointfor Cooler Cover Cart Part No Dv2.014.95.0.Pr , V Belt 2Jbx58 Pitch Length 1550 Cart Part No Dv2.016.02.0.00 , V Belt Spb Ar1250 (6 Nos. Set) Cart Part No Dv2.016.04.0.00 , V Belt Bx 1250 Ar Cart Part No Dv2.016.26.0.Pr , V-Belt-3Av15 X1275 Cart Part No Dv2.016.27.0.Pr , Lube Oil Sump Cart Part No Dv2.017.03.0.00 , Ecu Cart Part No Dv2.019.02.0.00 , High Pressure Pipe Assembly Cart Part No Dv2.021.130.0.00 , H.P Pipe (Cyl. No. 1 & 12) Cart Part No Dv2.021.31.0.00 , H P Pipecylno2 11 Cart Part No Dv2.021.32.0.00 , Hp Pipepump To Rail Lhs Cart Part No Dv2.021.38.0.Pr , Hp Pipepump To Rail Rhs Cart Part No Dv2.021.39.0.Pr , Clamp For Low Pressure Pipe (Dia 16) Cart Part No Dv2.021.58.0.00 , Rubber Sleeve (Dia 9) Cart Part No Dv2.021.59.0.00 , Hp Piperail To Fuel Pump Lhs Cart Part No Dv2.021.67.0.00 , Hp Piperail To Fuel Pump Rhs Cart Part No Dv2.021.68.0.00 , Rail Mtg Bracket Cart Part No Dv2.021.72.0.Pr , Hp Pipe Assemblyrouted For Cyl No4 10 Cart Part No Dv2.021.73.0.Pr , Hp Pipe Assemblyrouted For Cyl No5 11 Cart Part No Dv2.021.74.0.Pr , Hp Pipe Assemblyrouted For Cyl No6 12 Cart Part No Dv2.021.75.0.Pr , Hp Pipe Assemblyrouted For Cyl No7 Cart Part No Dv2.021.76.0.Pr , Hp Pipe Assemblypump To Rail Lhsfrom Few Cart Part No Dv2.021.77.0.Pr , Hp Pipe Assemblypump To Rail Rhs From Few Cart Part No Dv2.021.78.0.Pr , High Pressure Rail Right Bank Viewed From Pulley End Cart Part No Dv2.021.81.0.Pr , Fuel Pipefuel Pump To Main Filter Rh From Ge Cart Part No Dv2.022.103.0.00 , Rail Leak Off Pipe Assembly Cart Part No Dv2.022.106.0.00 , Fuel Pipepre Filter To Main Filter 1 Cart Part No Dv2.022.108.0.00 , Fuel Pipepre Filter To Main Filter 2 Cart Part No Dv2.022.109.0.00 , Fuel Pipe Assly Flexible Cart Part No Dv2.022.110.0.00 , Adaptorm16 To M18 Cart Part No Dv2.022.112.0.00 , Adaptor (M14 To M18) Cart Part No Dv2.022.113.0.00 , Deairazation Pipe Cart Part No Dv2.022.114.0.00 , Spigot (M22 To M18) Cart Part No Dv2.022.116.0.00 , Hosefor Fuel Pump Leak Off Cart Part No Dv2.022.117.0.00 , Common Head Leak Off Cart Part No Dv2.022.123.0.00 , Union Adaptorfor Head Leak Off Cart Part No Dv2.022.124.0.00 , Clamp For Fuel Pipe Cart Part No Dv2.022.125.0.Pr , Oil Supply Pipecrankcase To Fuel Pump In Cart Part No Dv2.022.126.0.00 , Low Pressure Pipe Clamp Pipe Dia 10 X 25 Crs Cart Part No Dv2.022.127.0.Pr , Adaptorm12xm16 Both End Male Cart Part No Dv2.022.142.0.00 , Filter To Pump Cart Part No Dv2.022.153.0.Pr , Fuel Pipe (Fuel Pump Leak Off Lh From Ge-1) Cart Part No Dv2.022.157.0.Pr , Pump Leak Off Cart Part No Dv2.022.159.0.Pr , Fuel Pipemain Filter To Fuel Pump Rh From Ge Cart Part No Dv2.022.165.0.00 , Fuel Pipemain Filter To Fuel Pump Lh From Ge Cart Part No Dv2.022.166.0.00 , Fuel Pipe (Fuel Pump Leak Off Rh From Ge) Cart Part No Dv2.022.167.0.00 , Fuel Pipefuel Pump Leak Off Lh From Ge Cart Part No Dv2.022.168.0.00 , Injector Leakoff Pipea Bank Cart Part No Dv2.022.172.0.Pr , Injector Leakoff Pipeb Bank Cart Part No Dv2.022.173.0.Pr , Fuel Pipeinjector Leakoff Pipe Cart Part No Dv2.022.174.0.Pr , Rail Leakoff Cart Part No Dv2.022.178.0.Pr , Leak Pipe Cart Part No Dv2.022.179.0.Pr , Fuel Pipepre Filter To Main Filter 1 Cart Part No Dv2.022.182.0.Pr , Fuel Pipepre Filter To Main Filter 2 Cart Part No Dv2.022.183.0.Pr , Fuel Pipemain Filter To Fuel Pump Rh From Ge Cart Part No Dv2.022.185.0.Pr , Adaptor For Pressure Sensor Cart Part No Dv2.022.66.0.00 , Adaptor For Pressure Sensor Cart Part No Dv2.022.66.0.Pr , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv2.022.71.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No Dv2.022.72.0.00 , Feed Pump Fuel In Pipe: Flex Cart Part No Dv2.022.73.0.00 , Fuel Pipe: Pump Leak Off: Flex Cart Part No Dv2.022.74.0.00 , Inlet Manifold Endr Hside Cart Part No Dv2.023.03.0.Pr , Dome Nut Cart Part No Dv2.023.06.0.Pr , Stud (185L) Cart Part No Dv2.023.07.0.Pr , Fan Pulley (185 Pcd & Spb Profile) Cart Part No Dv2.029.01.0.00 , Fan Pulley (3Groove, 222 Pcd) Cart Part No Dv2.029.04.0.00 , Special Studm12x1 75X142 L Cart Part No Dv2.029.07.0.00 , Fan Drive Assembly Cart Part No Dv2.029.120.0.00 , Fan Drive Assembly Cart Part No Dv2.029.220.0.Pr , Fan Drive Sub Assembly Cart Part No Dv2.029.230.0.Pr , Bracket For Fan Drive Arrangement Cart Part No Dv2.029.24.0.Pr , Pulley For Fan Drive Cart Part No Dv2.029.26.0.Pr , Fan Drive Assembly Cart Part No Dv2.029.30.0.00 , Spacer 50Mm For Dv12 Engine Cart Part No Dv2.029.71.0.00 , Fan Spacer Cart Part No Dv2.029.72.0.00 , Hose: Radiator To Engine Cart Part No Dv2.031.14.0.00 , Metalic Pipe From Thermo To Rad. Cart Part No Dv2.031.17.0.00 , Fan: 42 Dv12 Cart Part No Dv2.031.24.0.00 , 44 Fan For Dv12 With 45 Degblade Angle Cart Part No Dv2.031.25.0.00 , Pipe: Thermostat - Radiator Cart Part No Dv2.031.27.0.00 , Radiator Outlet Hose For Dv12e-750Kva Cart Part No Dv2.031.51.0.00 , 44Fan For Dv12 Cart Part No Dv2.031.56.0.00 , Radiator 750Kva Cart Part No Dv2.031.60.0.Pr , 42Fan For Dv2 Cart Part No Dv2.031.61.0.Pr , Heat Exchanger Pipe For Dv12 Cart Part No Dv2.031.65.0.00 , Radiator Inlet Pipe For Dv12e-750Kva Cart Part No Dv2.031.72.0.00 , Radiator Outlet Pipe For Dv12e-750Kva Cart Part No Dv2.031.74.0.00 , 44 Fan For Dv12export Cart Part No Dv2.031.86.0.Pr , Aluminium Radiator Assembly Cart Part No Dv2.031.87.0.Pr , Pipe From Thermostat To Radiator In Cart Part No Dv2.031.88.0.Pr , Rad Cac Hose Cart Part No Dv2.031.91.0.00 , Fan 58For 750Kva Cart Part No Dv2.031.94.0.Pr , Turbocharger (Left Bank From Fwe) Cart Part No Dv2.032.108.0.Pr , Turbocharger (Right Bank From Fwe) Cart Part No Dv2.032.109.0.Pr , Jointfor Flangefor T C Lub Oil Outlet Pipe Cart Part No Dv2.032.115.0.Pr , Jointbetbello Exh Manifold Cart Part No Dv2.032.14.0.Pr , Turbocharger: Dv12 750 Kva Engine Cart Part No Dv2.032.33.0.00 , Turbocharger For Dv12 750 Kva Engine - Right Bank(537819020896) Cart Part No Dv2.032.34.0.00 , Turbo Drain Pipe (Rh) (From Flywheel End) Cart Part No Dv2.032.37.0.00 , Turbo Drain Pipe Cart Part No Dv2.032.38.0.00 , Spacer I D 11Xo D 20X15l Cart Part No Dv2.032.41.0.00 , Turbo Drain Piperh From Flywheel End Cart Part No Dv2.032.43.0.Pr , Turbo Drain Pipelh From Flywheel End Cart Part No Dv2.032.44.0.Pr , Hose For Air Intak Adaptor Cart Part No Dv2.032.51.0.Pr , Left Bank Tcharger Cart Part No Dv2.032.97.0.00 , Right Bank Turbocharger Cart Part No Dv2.032.98.0.00 , Air Pipe (Dv2) From Turbo Compressor Out To Cac Cart Part No Dv2.033.03.0.00 , Cac Inlet Pip Cart Part No Dv2.033.06.0.00 , Cac Out Pipe Cart Part No Dv2.033.07.0.00 , Cac Pipe (Radiator Out) Cart Part No Dv2.033.101.0.Pr , Cac Piperadiator In Cart Part No Dv2.033.83.0.00 , O Ring: Cac Pipe Adaptor Cart Part No Dv2.033.85.0.00 , O Ringfor Cac Pipe Adaptor Cart Part No Dv2.033.86.0.Pr , Oringcac In Pipe Cart Part No Dv2.033.87.0.00 , Cam Shaft Cart Part No Dv2.040.03.0.00 , Cambox Type Fuel Pump Total Assydv2 Cart Part No Dv2.040.10.0.00 , Cambox Type Fuel Pump Total Assy (Dv2) Cart Part No Dv2.040.190.0.00 , Delivery Tube Cart Part No Dv2.042.10.0.00 , Delivery Tube Assembly Cart Part No Dv2.042.40.0.Pr , Breather Cart Part No Dv2.046.01.0.00 , Cartridge (Oil Separator) Cart Part No Dv2.046.02.0.00 , Injector Cart Part No Dv2.050.01.0.00 , Mechanical Injector With Side Fuel Entrysuitable For Mounting With Feedtube Cart Part No Dv2.050.13.0.Pr , Heat Shieldr H Cart Part No Dv2.051.16.0.00 , Heat Shieldl H Cart Part No Dv2.051.17.0.00 , Support Plate Cart Part No Dv2.051.20.0.00 , Heat Shieldr H Cart Part No Dv2.051.21.0.00 , Heat Shieldl H Cart Part No Dv2.051.22.0.00 , Heat Shieldrh Side End Mounted Cart Part No Dv2.051.23.0.00 , Breather Hose Breather To Breather Pipe Cart Part No Dv2.054.01.0.00 , Hose At Breather Side Cart Part No Dv2.054.92.0.00 , Breather Hose (From Pipe To Base Plate Cart Part No Dv2.054.93.0.00 , Oil Spray Nozzle Cart Part No Dv2.060.06.0.Pr , Crankcase Sub Assembly Cart Part No Dv2.060.180.0.Pr , Cable Type Anti Vibration Mounting Cart Part No Dv2.061.01.0.Pr , Anti Vibration Mount Engine Side Cart Part No Dv2.061.04.0.Pr , Rocker Box Cover (With Groove) Cart Part No Dv2.067.01.0.00 , Rocker Box: Clearance Cut Cart Part No Dv2.067.02.0.00 , O Ringfor Rocker Box Cover Cart Part No Dv2.067.03.0.Pr , Rocker Box Coverwith Groove Cart Part No Dv2.067.24.0.Pr , Rocker Box Cart Part No Dv2.067.25.0.Pr , Gasket (For Rocker Cover) Cart Part No Dv2.067.26.0.Pr , O Ring For Rocker Box Cart Part No Dv2.067.48.0.00 , Joint For Rocker Cover Cart Part No Dv2.067.49.0.00 , Breather Cart Part No Dv2.068.60.0.00 , Conical Copper Washer Cart Part No Dv2.069.07.0.00 , Oil Drain Pipe: Fip To Ccase Cart Part No Dv2.069.65.0.00 , Leak Off Pipe Cart Part No Dv2.069.85.0.00 , High Pressure Rail Left Bank Viewed From Pulley End Cart Part No Dv2.072.01.0.00 , High Pressure Rail For Right Bank Viewed From Pulley End Cart Part No Dv2.072.02.0.00 , High Pressure Cp3 3 Pump For Dv Engines Cart Part No Dv2.072.04.0.Pr , Mprop (Imv) For Cp3.3 Fip Cart Part No Dv2.072.10.0.Sp , Injector For Dv8ta 320 Kva Cpcb4 7 X 146 X 575K 1 3He 10 5 Cart Part No Dv2.072.171.0.Pr , Injector For Dv Series Cpcb4 7 X 146 X 850K 1 3He 10 5 Cart Part No Dv2.072.173.0.Pr , O Ring Between Gear Casing And Fuel Pump Cart Part No Dv2.072.24.0.Pr , Gear Casingfor Dv12 Crdi Cart Part No Dv2.072.25.0.Sp , Plate For Cam Sensor Location Cart Part No Dv2.072.57.0.00 , Cam Sensor Locator Cart Part No Dv2.072.58.0.00 , Bridge For Cam Sensor Cart Part No Dv2.072.69.0.00 , O Ring (For Cam Sensor Locator) Cart Part No Dv2.072.71.0.00 , Belleville Washer For Cam Sensor Cart Part No Dv2.072.77.0.00 , Inlet Connectorfeedtube Cart Part No Dv2.072.88.0.00 , Retaining Nut Cart Part No Dv2.072.89.0.00 , Injector For Dv Crdi Engine Cart Part No Dv2.072.92.0.00 , Tdc Sensor Wheel For Common Rail Cart Part No Dv2.076.01.0.Pr , Bracket For Fuel Filter Cart Part No Dv2.079.02.0.Pr , Bracket For Prefilter Cart Part No Dv2.079.04.0.Pr , Adaptor For Inlet Manifold2 Port Cart Part No Dv2.081.01.0.00 , Adaptor (M16xm22) Cart Part No Dv2.082.48.0.00 , Breather Housing (For Pipavav) Cart Part No Dv2.086.129.0.Pr , Joint Bet. Breather & Gear Casing (Pipavav) Cart Part No Dv2.086.132.0.00 , Air Side Cover Outlet (For Cac) Cart Part No Dv2.086.139.0.Pr , Rubber Sleeve For Fuel Pipe Cart Part No Dv2.086.156.0.00 , Clamp For Fuel Pipe Cart Part No Dv2.086.157.0.00 , Turbo Oil Drain Pipemarine Cart Part No Dv2.086.165.0.Pr , Turbo Oil Drain Pipe Cart Part No Dv2.086.202.0.Pr , Joint For Flywheel Housing Cart Part No Dv2.086.32.0.00 , Turbo Adaptorrh Cart Part No Dv2.086.37.0.00 , Turbo Oil Supply Pipe Rh Cart Part No Dv2.086.47.0.00 , Turbo Oil Supply Pipe(Lh) Cart Part No Dv2.086.48.0.00 , Hose For Turbo Compressor Out Cart Part No Dv2.086.52.0.00 , Plate For Thermostat (Marine) Cart Part No Dv2.086.78.0.00 , Joint For Cooler Cover (Lh) (From Fwe) Cart Part No Dv2.086.85.0.00 , Joint For Cooler Cover (Rh) (From Fwe) Cart Part No Dv2.086.86.0.00 , Joint (Between Cac & Turbo-Adaptor) Cart Part No Dv2.086.87.0.00 , Hosedia 48 Betsleeve Pipe Cart Part No Dv2.087.02.0.00 , Hosedia 54 Bet2 Pipes Cart Part No Dv2.087.03.0.00 , Breather Pipe Clampon Cac Cover Front Cart Part No Dv2.087.06.0.00 , Breather Pipe Clampon Gear Casing Cart Part No Dv2.087.07.0.00 , Clamp On Gearcasing Cart Part No Dv2.087.13.0.00 , Breather Pipe Cart Part No Dv2.087.15.0.Pr , Breather Pipe Dia 44 5Extended Cart Part No Dv2.087.16.0.Pr , Bracket For Breather Pipe Cart Part No Dv2.087.17.0.Pr , Cac For Domestic Application Cart Part No Dv2.087.46.0.Pr , Dcu Wiring Harness Sf Dv12 Cpcb Iv Engine Cart Part No Dv2.112.50.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Ivecu Chamber 1 Cart Part No Dv2.114.10.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 2 3 4 Cart Part No Dv2.114.20.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv2.114.30.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 8 Cart Part No Dv2.114.40.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Ivecu Chamber 1 Cart Part No Dv2.114.60.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv2.115.10.0.Pr , Silencer For Dv Series Cart Part No Dv2.188.10.0.00 , Silencer For Dv 500 - 750 Kva Cart Part No Dv2.188.80.0.00 , Bush -For Lifting Genset In Canopy -M20 X 2.5 X 35 Od Cart Part No Dv2.326.31.0.Pr , Metallic Pipe Engine To Egt (Rhs Side From F.W.E.) Cart Part No Dv2.477.08.0.Pr , Coolant Pipe Forengine Out To Dosing Model In 1 Rhs Egt F W E Cart Part No Dv2.477.11.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Lhs Egt F W E Cart Part No Dv2.477.14.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) (Rhs Egt F.W.E.) Cart Part No Dv2.477.16.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Rhs Egt F W E Cart Part No Dv2.477.19.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) (Lhs Egt F.W.E.) Cart Part No Dv2.477.21.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-1) (Lhs Egt F.W.E.) Cart Part No Dv2.477.31.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 4 Rhs Egt F W E Cart Part No Dv2.477.74.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-2) (Rhs Egt F.W.E.) Cart Part No Dv2.477.76.0.Pr , Metallic Pipe Engine To Egt (Lhs Side From F.W.E.) Cart Part No Dv2.477.77.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) (Lhs Egt F.W.E.) Cart Part No Dv2.477.78.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-3) (Rhs Egt F.W.E.) Cart Part No Dv2.477.79.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Lhs Tank Side Cart Part No Dv2.477.83.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Lhs Tank Side Cart Part No Dv2.477.84.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-3) Lhs Tank Side Cart Part No Dv2.477.86.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Lhs Tank Side Cart Part No Dv2.477.88.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv2.477.89.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Rhs Tank Side Cart Part No Dv2.477.92.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Rhs Tank Side Cart Part No Dv2.477.93.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-3) Rhs Tank Side Cart Part No Dv2.477.94.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Rhs Tank Side Cart Part No Dv2.477.96.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-2) Rhs Tank Side Cart Part No Dv2.477.97.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-2) Rhs Tank Side Cart Part No Dv2.477.98.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv2.477.99.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-1) (Lhs Egt F.W.E.) Cart Part No Dv2.478.02.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Rhs Egt F W E Cart Part No Dv2.478.04.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-1) (Rhs Egt F.W.E.) Cart Part No Dv2.478.21.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-3) (Rhs Egt F.W.E.) Cart Part No Dv2.478.23.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-4) (Rhs Egt F.W.E.) Cart Part No Dv2.478.24.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Lhs Egt F W E Cart Part No Dv2.478.26.0.Pr , Coolant Pipe Forengine Out To Dosing Model In 3 Lhs Egt F W E Cart Part No Dv2.478.28.0.Pr , Copper Radiator Assembly Cart Part No Dv2.486.10.0.Pr , Hose Reducer Elbow For 600Kva Genset Cart Part No Dv2.505.01.0.00 , Hose Reducer Elbow Cart Part No Dv2.505.02.0.00 , Hose From Pipe To Turbocharger Cart Part No Dv2.505.07.0.00 , Air Cleaner Lh Side Cart Part No Dv2.505.10.0.00 , Metalic Pipe For Dv12 Cart Part No Dv2.505.16.0.00 , Air Cleaner Kit Cart Part No Dv2.505.50.0.00 , Air Cleaner Kit Cart Part No Dv2.505.60.0.00 , Air Cleaner Hosebetween Pipe And Air Cleaner Cart Part No Dv2.505.86.0.Pr , Elbow Hose Cart Part No Dv2.506.01.0.00 , Hose Clamp Cart Part No Dv2.506.03.0.00 , Pre Cleaner Metal Cart Part No Dv2.506.10.0.00 , Air Cleaner Assly. Cart Part No Dv2.506.60.0.00 , Air Filter Safety Cart Part No Dv2.506.62.0.00 , Air Filter Primary Cart Part No Dv2.506.63.0.00 , Fuel Pipe Tank To Leak Off Pipe Cart Part No Dv2.507.02.0.00 , Fuel Pipe: Fuel Tank To Fuel Prefilter Cart Part No Dv2.507.03.0.00 , Fuel Pipe Return Cart Part No Dv2.507.15.0.00 , Fuel Pipe ( Return ) For 750 Kva Cart Part No Dv2.507.22.0.00 , Fuel Inlet Pipe (From Tank To Pre-Filter)Straight Cart Part No Dv2.507.23.0.00 , Fuel Inlet Pipe (From Tank To Pre-Filter)Bend Cart Part No Dv2.507.24.0.00 , Fuel Pipes From Tank To Prefilter Cart Part No Dv2.507.26.0.Pr , Fuel Pipes From Tank To Prefilter Cart Part No Dv2.507.27.0.Pr , Fuel Return Pipem16x1 5 Male Plug And M22x1 5 Union Nut Cart Part No Dv2.507.32.0.Pr , Fuel Inlet Pipe From Tank To Pre Filterm22x1 5 Union Nut And M22x1 5 Banjo Cart Part No Dv2.507.33.0.Pr , Koel Green Alternatorkg 750 S T Framel Kg 49 1 M75sae 1 14415V50hz0 8P F750 H H Cart Part No Dv2.701.05.0.Pr , 25Afuse Cart Part No Dv2.710.02.0.Pr , 40Afuse Cart Part No Dv2.710.03.0.Pr , 80Afuse Cart Part No Dv2.710.05.0.Pr , 30Afuse Cart Part No Dv2.710.11.0.Pr , Koel Green Alternatorkg 625 S T Framel Kg 47 E1sae 1 14 415V50 Hz0 8 Pf Cart Part No Dv2.801.35.0.Pr , Rain Cap Assembly For Exhaust Bend Cart Part No Dv2.806.23.0.00 , Tail Pipe Cart Part No Dv2.806.25.0.00 , Exhaust Bend Cart Part No Dv2.806.65.0.Pr , Engine Mtg Foot For 750 Kva Baseframe Cart Part No Dv2.850.51.0.00 , 4 Pin Connector (Female Conector Male Pins) Cart Part No Dv2.852.28.0.00 , Assembly For Rmsremote Monitoring Systemunit For Kg934 Cart Part No Dv2.858.12.0.00 , Assembly For Krm Unit For Kg541 With Package Cart Part No Dv2.858.14.0.Pr , Assembly For Krm Unit For Kg745 With Package Cart Part No Dv2.858.27.0.Pr , Assembly For Krm Unit For Kg645 With Package Cart Part No Dv2.858.29.0.Pr , Krms Device Sf Rdso Projectforkg745 Unit With 2 Years Data Package Inclusiv Cart Part No Dv2.858.31.0.Pr , Assembly For Krm Unit For Kg645c With Package Cart Part No Dv2.858.39.0.Pr , Krm Unit With Package For Kg745(With Cpcb4) Rs232 With Package Cart Part No Dv2.858.49.0.Pr , Assembly For Rmsremote Monitoring Systemunit Cart Part No Dv2.858.80.0.00 , Protocol Rs485 To Snmp Convertor Module Cart Part No Dv2.858.85.0.Pr , Push Button Cart Part No Dv2.860.48.0.00 , 1600A 4P Acb ( Edo ) Type-3Wj1116-2Af62-4Dh0- Z T40+ F40 Cart Part No Dv2.863.77.0.00 , Motorised Mccb Compact 36 Ka At 415 Vac, Nsx250n, & 4P, 250A, Cart Part No Dv2.863.79.0.00 , Motor Mechanism, Mt 250, Compact Nsx250, Powerpact Multi Standard L, Cart Part No Dv2.863.81.0.00 , Mccb 1 Aux.Switch Cart Part No Dv2.863.82.0.00 , Motorised Mccb Compact 36Ka At 415 Vac, Micrologic 2.3 Trip Unit Nsx400f, Cart Part No Dv2.863.85.0.00 , Motor Mechanism, Mt 400-630, Compact Nsx400/630, Powerpact Multistandard L, 220 Cart Part No Dv2.863.86.0.00 , Earthing Cable Panel To Base Plate For 600Kva Cart Part No Dv2.866.01.0.00 , Rra Assembly Kg49 1 Kva Ratings 625 To 750 Kva 3Ph Cart Part No Dv2.901.01.0.Asp , Fan-Kg49.1,Kva Rating-625 To 750Kva,3Ph Cart Part No Dv2.901.04.0.Asp , Varister-Kg49.1,Kva Rating-625 To 750Kva,3Ph. Cart Part No Dv2.901.05.0.Asp , Coupling Disckg49 1 Kva Rating 625 To 750Kva 3Ph Cart Part No Dv2.901.12.0.Asp , Set Of 3 Ct 1000/5 Ls Frame - Kg 47.2 Cart Part No Dv2.901.14.0.Asp , Ex. Rotor With Rra Frame 38 8P Cart Part No Dv2.901.22.0.00 , Fan Assembly Pdc Kg 38 Cart Part No Dv2.901.23.0.00 , Coolant Level Switchlow High Level With Led Cart Part No Dv2.901.26.0.00 , Kit Pd500 For Eco 38 Aairgap 0.4 Cart Part No Dv2.901.37.0.00 , Diode Assembly Kg44 3 Cart Part No Dv2.901.57.0.00 , Coupling Disc Kg44.3 Cart Part No Dv2.901.59.0.00 , Coupling Disc Set Sae 11.5 Kg 42.3 Cart Part No Dv2.901.63.0.00 , Diode Bridge Rectifier Kg40 Cart Part No Dv2.901.64.0.00 , Rra Assembly Kg 47.2 Cart Part No Dv2.901.65.0.00 , Varister Kg47.2 Cart Part No Dv2.901.90.0.00 , Adaptor For Pressure Sensor Cart Part No Dv2.903.03.0.00 , Adaptor For Gems Lop Sensor Cart Part No Dv2.903.06.0.00 , Clamps Cart Part No Dv2.903.16.0.Pr , Clamps Cart Part No Dv2.903.17.0.Pr , Wiring Harness From Engine Control Panel To Alternator Terminal Box With Ct S Cart Part No Dv2.903.30.0.00 , Crank Speed Hall Effect Sensor Cart Part No Dv2.903.31.0.00 , Cam Speed Hall Effect Sensor Cart Part No Dv2.903.32.0.00 , Insulatorm6 X 25Mmlength Cart Part No Dv2.903.36.0.Pr , Insulator For Ecuorder Number 20A F M6 30Mm Cart Part No Dv2.903.46.0.Pr , Clamp For Injector Connector Cart Part No Dv2.903.77.0.Pr , Special Black Tie For Crdi Cart Part No Dv2.903.78.0.00 , Resting Plate For Ecu Cart Part No Dv2.904.35.0.Pr , Ecu Mounting Plate Cart Part No Dv2.904.36.0.Pr , Support Bracket For Resting Plate Cart Part No Dv2.904.37.0.Pr , Support Bracket For Resting Plate Cart Part No Dv2.904.38.0.Pr , Ecu Mounting Support Channel Cart Part No Dv2.904.39.0.Pr , Cable Gland Assembly For Dv Engine Cart Part No Dv2.906.10.0.00 , Wiring Harnessfrom Interface Card To Control Panel For Dv12 Cart Part No Dv2.906.20.0.Pr , Wiring Harness From Interface Relay Box To Master Ecu For Dv12 Cart Part No Dv2.906.30.0.Pr , Wiring Harness From Interface Relay Box To Slave Ecu For Dv12 Cart Part No Dv2.906.40.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection For Dv12 Cart Part No Dv2.906.50.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection For Dv12 Cart Part No Dv2.906.60.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection With Pump F Cart Part No Dv2.906.70.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection With Pump Fo Cart Part No Dv2.906.80.0.Pr , Control Panel For Dv12 750Kva Crdi Genset Cart Part No Dv2.906.90.0.Pr , Battery Cable Assembly70 Sq Mm With Suitable Lug Cart Part No Dv2.908.40.0.00 , Wiring Harness From Master Ecu To Sensor Cart Part No Dv2.909.50.0.Pr , Wiring Harness From Slave Ecu To Sensor Cart Part No Dv2.909.60.0.Pr , Engine Wiring Harness Assemblyfor Dv12 Engine With Kg545 Unit 4 20 Ma Gems Lo Cart Part No Dv2.910.50.0.00 , Engine Wiring Harness Assembly & 4-20 Ma Cart Part No Dv2.910.60.0.00 , Engine Wiring Harness Assemblyfor Dv12 Engine & 4-20 Ma Gems Lop Sensor Cart Part No Dv2.910.70.0.Pr , Wiring Harness From Master Ecu To Sensor And Injector Connection Cart Part No Dv2.911.50.0.Pr , Wiring Harness From Slave Ecu To Sensor And Injector Connection Cart Part No Dv2.911.60.0.Pr , Engine Control Panel To Alternator Ct Harness For Genset 2 Cart Part No Dv2.913.95.0.Pr , Crdi Interface Card Cart Part No Dv2.989.24.0.00 , Joint For Raw Water Pipe Assembly (120 Od X 60 Id X 95 Pcd) Cart Part No Dv2.993.23.0.00 , Crdi Can Cable Genset Panel To Pc Cart Part No Dv2.999.01.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.9101... - Dv12eta G11 Cart Part No Dv2.999.02.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.1246, Dv2.8301, Dv2.1045 - Dv12 Sr1 Cart Part No Dv2.999.62.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.8304 - Dv12ta Cart Part No Dv2.999.63.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.9104 - Dv12eta G11 Cart Part No Dv2.999.64.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.8309 - Dv12ta G2 Cart Part No Dv2.999.65.0.Sp , Wet Pm Kit (W/O Oil) For Dv2.9205 Cart Part No Dv2.999.66.0.Sp , Wet Pm Kit (W/O Oil ) For Dv2.9110 Cart Part No Dv2.999.72.0.Sp , Wet Pm Kit (W/O Oil ) For Dv2.8311 Cart Part No Dv2.999.73.0.Sp , Dc2 Controller For Dv12 Engine Cart Part No Dv2.M002.02.0.00 , Clamp For Pipeo D 22 Cart Part No Dv2.W022.27.0.Pr , V Band Clampdia 104 Cart Part No Dv2.W032.21.0.Pr , O Ring For Heat Exchanger Cart Part No Dv2.W055.02.0.Pr , Crankcase Sub Assly. Cart Part No Dv8.001.10.0.00 , Crankcase Sub Assly Cart Part No Dv8.001.240.0.Pr , Crankshaft (Sub Assly) Cart Part No Dv8.003.10.0.00 , Crankshaft Gear Cart Part No Dv8.003.13.0.Pr , Cam Gearfinish Cart Part No Dv8.004.03.0.Pr , Cam Shaft & Gear Assembly Cart Part No Dv8.004.94.0.00 , Piston Assembly Kit Dv8 Cart Part No Dv8.006.04.0.Sp , Bridge For Rocker Lever Cart Part No Dv8.007.14.0.Pr , Bridge For Rocker Lever Cart Part No Dv8.007.18.0.00 , Bridge For Rocker Lever Cart Part No Dv8.007.18.0.Pr , Double Gear Assembly Cart Part No Dv8.010.70.0.Pr , Sub Assly Of Intermediate Gear Bush Cart Part No Dv8.011.10.0.Pr , Driving Gear Lop Cart Part No Dv8.013.06.0.00 , Pipe Thermostat To Radiator In Cart Part No Dv8.014.21.0.00 , Hose (Radiator To Engine) Cart Part No Dv8.014.22.0.00 , Lube Oil Sump Cart Part No Dv8.017.03.0.00 , Fabricated Sump Cart Part No Dv8.017.24.0.Pr , Fuel Pump Gearfinish Cart Part No Dv8.019.03.0.Pr , High Pressure Pipe Assembly Cart Part No Dv8.021.130.0.00 , Balancing Pipe Assemblyfor Rail Cart Part No Dv8.021.440.0.Pr , Fuel Pipefeed Pump To Filter Cart Part No Dv8.022.101.0.00 , Fuel Pipe (Tank To Feed Pump In) Cart Part No Dv8.022.103.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv8.022.104.0.00 , Fuel Pipe For Filter To Pump (Flexible) Cart Part No Dv8.022.105.0.00 , Fuel Pipe For Feed Pump To Filter (Flexible) Cart Part No Dv8.022.106.0.00 , Fuel Pipefeed Pump To Filter Cart Part No Dv8.022.114.0.Pr , Fuel Pipefuel Filter To Fuel Pump Cart Part No Dv8.022.115.0.Pr , Fuel Pipemain Filter To Fuel Pump Lh From Ge Cart Part No Dv8.022.129.0.Pr , Fuel Pipe (Fuel Pump Leak Off Lh From Ge) Cart Part No Dv8.022.132.0.Pr , Leak Off Pipeabanklh From Ge Cart Part No Dv8.022.136.0.Pr , Leak Off Pipebbankrh From Ge Cart Part No Dv8.022.137.0.Pr , Leak Off Pipe (End Connection) Cart Part No Dv8.022.138.0.Pr , Fuel Pipe (Rail Leak Off) Cart Part No Dv8.022.139.0.Pr , Fuel Pipe Assly Cart Part No Dv8.022.140.0.00 , Fuel Pipe Pri Filter To Main Filter Cart Part No Dv8.022.152.0.Pr , Leak Off Pipe B Bank Cart Part No Dv8.022.155.0.Pr , Leak Off Pipe A Bank Cart Part No Dv8.022.156.0.Pr , Leak Off Pipe (End Connection) Cart Part No Dv8.022.157.0.Pr , Fuel Pipe Assembly Cart Part No Dv8.022.160.0.00 , Hose (250 Mm For Dv8 Power Car ) Cart Part No Dv8.022.164.0.Pr , Fuel Pipe Assemblyflexible Cart Part No Dv8.022.170.0.Pr , Adaptor (M14*1.5 & M16*1.5) Cart Part No Dv8.022.41.0.00 , Fuel Pipefeed Pump To Filter Cart Part No Dv8.022.68.0.Pr , Fuel Pipe: Fuel Filter To Fip Cart Part No Dv8.022.71.0.00 , Fuel Pipe: Feed Pump To Filter Cart Part No Dv8.022.72.0.00 , Feed Pump Fuel In Pipe (Flex) Cart Part No Dv8.022.73.0.00 , Fuel Pipe: Pump Leak Off (Flex) Cart Part No Dv8.022.74.0.00 , Fuel Pipe For Main Filter Leakoff Cart Part No Dv8.022.78.0.Pr , Clamp Cart Part No Dv8.022.79.0.Pr , Air Pipe Clamp (Bottom) Cart Part No Dv8.023.18.0.Pr , Adaptor (For Heater Tothrottle Body) Cart Part No Dv8.023.23.0.Pr , Adaptor For Inlet Manifold (2 Port) Cart Part No Dv8.023.24.0.Pr , Jointbetween Throttle Valve And Heater Cart Part No Dv8.023.26.0.Pr , Air Pipe Clamp Cart Part No Dv8.023.31.0.Pr , Exhaust Manifold (L.H. 2 Port ) Cart Part No Dv8.024.14.0.00 , Exhaust Manifold (R.H. 2 Port ) Cart Part No Dv8.024.15.0.00 , Support: Exhaust Elbow Lh Side Cart Part No Dv8.024.21.0.00 , Support: Exhaust Elbow Rh Side Cart Part No Dv8.024.22.0.00 , Fan Drive Assembly Cart Part No Dv8.029.165.0.00 , Fan Drive Asm Cart Part No Dv8.029.30.0.00 , Radiator Water Out Hose Cart Part No Dv8.031.04.0.00 , Silicon Hose 3.5 Id Cart Part No Dv8.031.05.0.00 , Clamp Assembly For Thermostat To Rad. In Pipe Cart Part No Dv8.031.91.0.Pr , Y-Shape Gas Connection Pipe Cart Part No Dv8.031.92.0.Pr , Breather Hose Cart Part No Dv8.031.96.0.Pr , Bracket For Turbo Adaptor Rh From Gear End Cart Part No Dv8.032.05.0.00 , Turbo Adaptorr Hfrom F Wend Cart Part No Dv8.032.18.0.00 , Turbocharger For Dv8,320 Kva Engine-A Bank Cart Part No Dv8.032.21.0.00 , Turbocharger For Dv8 Cart Part No Dv8.032.22.0.00 , Left Bank Tcharger Cart Part No Dv8.032.31.0.00 , Right Bank Turbocharger Cart Part No Dv8.032.32.0.00 , Turbo Adaptorlh From G E Cart Part No Dv8.032.33.0.00 , Spacer: Turbo Adaptor Cart Part No Dv8.032.34.0.00 , B/W Turbo Charger & Diffuser Cart Part No Dv8.032.57.0.Pr , Turbocharger Assly (R.H. From Ge) Cart Part No Dv8.032.72.0.Pr , Turbocharger Assly (L.H. From Ge) Cart Part No Dv8.032.73.0.Pr , Hose( For Air Inlet Adaptor ) Cart Part No Dv8.032.75.0.Pr , Air Pipe From Turbo Compressor Out To Cac Cart Part No Dv8.033.03.0.00 , Exhaust Elbow Cart Part No Dv8.033.04.0.00 , Gasket (For Cac Pipe ) Cart Part No Dv8.033.108.0.Pr , Rubber Bush (For Cacpipe) Cart Part No Dv8.033.109.0.Pr , V Band Clamp 77Mm Nom Dia Cart Part No Dv8.033.32.0.00 , Turbo Compressor Out Pipe (Lhview From Fwe) Cart Part No Dv8.033.34.0.00 , Turbo Compressor Out Pipe (Rhview From Fwe) Cart Part No Dv8.033.35.0.00 , Turbo Compressor Cart Part No Dv8.033.36.0.00 , Turbo Compressor Cart Part No Dv8.033.37.0.00 , V Band Clamp76 2Mm Nom Dia Cart Part No Dv8.033.38.0.Pr , Cac Pipe Cart Part No Dv8.033.43.0.00 , Cac Out Pipe Cart Part No Dv8.033.44.0.00 , Expansion Bellow 110 Id Cart Part No Dv8.033.45.0.Pr , V Band Clamp Cart Part No Dv8.033.67.0.Pr , Cac Pipe For Dv8 Engine Cart Part No Dv8.033.86.0.Pr , Hose: Radiator To Engine Cart Part No Dv8.035.04.0.00 , Pipe Thermostat To Rad In Cart Part No Dv8.035.05.0.00 , Suction Pipe: Radiator To Engine Cart Part No Dv8.035.20.0.00 , Hose Turbo To Pipe Cart Part No Dv8.035.33.0.00 , Copper Radiator Assembly Cart Part No Dv8.035.75.0.Pr , Pipe Thermostat To Rad In Cart Part No Dv8.035.77.0.Pr , Aluminium Radiator Assy Cart Part No Dv8.036.10.0.00 , Camshaft(For Pf33(N) Fuel Pump Cart Part No Dv8.040.03.0.00 , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.10.0.00 , Rack Control Rod For Fuel Pump Cart Part No Dv8.040.19.0.00 , Pump With Dual Helix Element Cart Part No Dv8.040.22.0.00 , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.220.0.00 , Fuel Filter & Water Seperator Cart Part No Dv8.040.23.0.00 , Spinon Fuel Filter Assly Cart Part No Dv8.040.24.0.00 , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.250.0.00 , Water Separator Filter Remover Racor Bowl Wrench Cart Part No Dv8.040.33.01.Tol , Cambox Type Fuel Pumptotal Asslydv8 Cart Part No Dv8.040.430.0.00 , Sub Assly Of Delivery Tube Cart Part No Dv8.042.10.0.00 , Breather Hose Cart Part No Dv8.050.05.0.00 , Heat Shield (R.H) Cart Part No Dv8.051.03.0.00 , Center Bracket (For Heat Shield(R.H) ) Cart Part No Dv8.051.06.0.00 , Heat Shield (L.H) Cart Part No Dv8.051.07.0.00 , Bracket (For Heat Shield G.E. (L.H) ) Cart Part No Dv8.051.11.0.00 , Heat Shield (R.H. (For Modified Exhaust Manifold Cart Part No Dv8.051.14.0.00 , Heat Shield L H For Modified Exhaust Manifold Cart Part No Dv8.051.15.0.00 , Laggingfor Dv8 Diffuser Lhs From Few Cart Part No Dv8.051.42.0.Pr , Laggingfor Dv8 Diffuser Rhs From Few Cart Part No Dv8.051.43.0.Pr , Lagging For Turbo Adaptorrhs From Few Cart Part No Dv8.051.44.0.Pr , Lagging For Turbo Adaptorlhs From Few Cart Part No Dv8.051.45.0.Pr , Lower Heat Shield Rh From Fwe Cart Part No Dv8.051.53.0.Pr , Lower Heat Shield Lh From Fwe Cart Part No Dv8.051.55.0.Pr , Fan: 36 Plastic Cart Part No Dv8.052.01.0.00 , Fan Cart Part No Dv8.052.06.0.00 , Spacer ( 175Mm) For Dv8 Fan Cart Part No Dv8.053.03.0.00 , Fan Spacer 125Mm Length Cart Part No Dv8.053.05.0.00 , Breather Hose (From Pipe To Base Plate) Rh Side From F.W.E Cart Part No Dv8.054.11.0.Pr , Breather Hose (From Pipe To Base Plate) Lh Side From F.W.E Cart Part No Dv8.054.12.0.Pr , Joint: Turbo Outlet Cart Part No Dv8.064.01.0.00 , Oil Drain Pipe: Fip-Ccase Cart Part No Dv8.069.65.0.00 , Leak Off Pipe Cart Part No Dv8.069.85.0.00 , Fuel Filter For Common Rail Cart Part No Dv8.072.01.0.00 , 50 Hrs - A Check Maintenance Kit Cart Part No Dv8.072.02.0.Sp , Intermediate Gear Support Cart Part No Dv8.072.107.0.00 , Final Filter Cartridge Cart Part No Dv8.072.108.0.00 , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv8.072.12.0.Sp , Final Filter With Lift Pump For Dv Crdi Project17 Psi Pressure Regulator Cart Part No Dv8.072.121.0.Pr , Final Filter With Lift Pump For Dv Crdi Project8 Psi Pressure Regulator Cart Part No Dv8.072.122.0.Pr , 500 Hrs - B Check Maintenance Kit Cart Part No Dv8.072.125.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Dv8.072.13.0.Sp , Sub Assly Of Intgear Bush Cart Part No Dv8.072.150.0.Pr , Joint: Gear Casing Cart Part No Dv8.072.27.0.00 , Joint For Gear Casing Cover Cart Part No Dv8.072.28.0.00 , Joint Forfuel Pump Cart Part No Dv8.072.48.0.00 , Nut (M18x1.5) (Hard Nut) Cart Part No Dv8.072.88.0.00 , Retainer Plate For Cr Intgear Support Cart Part No Dv8.072.92.0.00 , Retainer Plate For Cr Double Gear Support Cart Part No Dv8.072.94.0.00 , Fan Clutch Asembly For Dv8 Cart Part No Dv8.076.10.0.Pr , Tdc Sensor Wheel For Common Rail Cart Part No Dv8.081.01.0.Pr , Flywheel Assembly Cart Part No Dv8.081.10.0.Pr , Woodward Pg Plus System For 8 Cylinder Natural Gas Engine Cart Part No Dv8.087.100.0.Pr , Throttle Body L Series 50Mm Cart Part No Dv8.087.50.0.Pr , Expansion Bellowfor Exhmanifold Cart Part No Dv8.088.22.0.Pr , External Exhaust Manifold Lagging For Dv8 Cart Part No Dv8.088.26.0.Pr , Jointbet Exh Maniand Adaptor Cart Part No Dv8.088.31.0.Pr , Gas Train Assembly For Dv8 Ta Png Cart Part No Dv8.088.50.0.Pr , Wiring Harness Boxlh Side Cart Part No Dv8.099.130.0.Pr , Wiring Harness Boxrh Side Cart Part No Dv8.099.140.0.Pr , Dcu Wiring Harness Sf Dv8 Cpcb Iv Cart Part No Dv8.112.50.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 1 Cart Part No Dv8.114.10.0.Pr , Engine Wiring Harness Sf Dv12 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv8.114.30.0.Pr , Engine Wiring Harness Sf Dv10 Cpcb Ivecu Chamber 8 Cart Part No Dv8.114.40.0.Pr , Engine Wiring Harness Sf Dv8 Cpcb Iv Ecu Chamber 5 6 7 Cart Part No Dv8.114.50.0.Pr , Engine Wiring Harness Sf Dv8 Engine Ecu Chember 1 For Cpcb Iv Cart Part No Dv8.114.60.0.Pr , Engine Wiring Harness Sf Dv8 Cpcb Iv Ecu Chamber 5,6,7 Engine A Cart Part No Dv8.115.10.0.Pr , Engine Wiring Harness Sf Dv8 Cpcb Iv Ecu Chamber 5,6,7 Engine B Cart Part No Dv8.115.20.0.Pr , Canopy Wiring Harness Sf 500X2 Optiprime Split Canopy Project Cart Part No Dv8.115.40.0.Pr , Flange Heater 24V 2Kw For Dv Series Cart Part No Dv8.1172.02.0.00 , Engine Plug Heater For Dv Series Cart Part No Dv8.1172.03.0.Pr , Flange For Bellow Cart Part No Dv8.188.05.0.00 , Silencer Cart Part No Dv8.188.10.0.00 , Adaptor M14 X M10 Cart Part No Dv8.235.01.0.Pr , Raw Water Pipecac Out To H E Cart Part No Dv8.301.08.0.Pr , Raw Water Pipeon He Inlet Cart Part No Dv8.301.17.0.Pr , Raw Water Pipecac Out To H E Cart Part No Dv8.301.18.0.Pr , Hose For Air Cleaner Cart Part No Dv8.303.04.0.00 , Hose For Air Cleaner Cart Part No Dv8.303.07.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Rhs Egt F W E Cart Part No Dv8.478.02.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) (Rhs Egt F.W.E.) Cart Part No Dv8.478.03.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-3) (Rhs Egt F.W.E.) Cart Part No Dv8.478.04.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-4) (Rhs Egt F.W.E.) Cart Part No Dv8.478.05.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Lhs Egt F W E Cart Part No Dv8.478.07.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) (Lhs Egt F.W.E.) Cart Part No Dv8.478.08.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Lhs Egt F W E Cart Part No Dv8.478.09.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-1) (Rhs Egt F.W.E.) Cart Part No Dv8.478.13.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-2) (Rhs Egt F.W.E.) Cart Part No Dv8.478.14.0.Pr , Coolant Pipe For (Engine Out To Dosing Model In-1) (Lhs Egt F.W.E.) Cart Part No Dv8.478.17.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Rhs Egt F W E Cart Part No Dv8.478.25.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) (Lhs Egt F.W.E.) Cart Part No Dv8.478.28.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Lhs Tank Side Cart Part No Dv8.478.31.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Lhs Tank Side Cart Part No Dv8.478.32.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 3Lhs Tank Side Cart Part No Dv8.478.33.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Lhs Tank Side Cart Part No Dv8.478.35.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv8.478.36.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv8.478.37.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Rhs Tank Side Cart Part No Dv8.478.39.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Rhs Tank Side Cart Part No Dv8.478.41.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-3) Rhs Tank Side Cart Part No Dv8.478.42.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Rhs Tank Side Cart Part No Dv8.478.44.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Rhs Tank Side Cart Part No Dv8.478.45.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Rhs Tank Side Cart Part No Dv8.478.46.0.Pr , Metallic Pipe Engine To Egtrhs Side From F W E Cart Part No Dv8.478.47.0.Pr , Coolant Pipe Forengine Out To Dosing Model In 1 Cart Part No Dv8.478.48.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 2 Lhs Egt F W E Cart Part No Dv8.478.53.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Lhs Egt F W E Cart Part No Dv8.478.54.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 2 Rhs Egt F W E Cart Part No Dv8.478.56.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Rhs Egt F W E Cart Part No Dv8.478.57.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 4 Rhs Egt F W E Cart Part No Dv8.478.58.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Lhs Egt F W E Cart Part No Dv8.478.59.0.Pr , Adblue Pipe Foradblue Tank Out To Supply Module In 2Rhs Tank Side Cart Part No Dv8.478.62.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Rhs Tank Side Cart Part No Dv8.478.63.0.Pr , Adblue Pipe Forsupply Module Back Flow To Adblue Tank In 2Lhs Tank Side Cart Part No Dv8.478.64.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Lhs Tank Side Cart Part No Dv8.478.66.0.Pr , Coolant Pipe For (Dosing Module Out To Radiator In-2) (Rhs Egt F.W.E.) Cart Part No Dv8.478.84.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Lhs Egt F W E Cart Part No Dv8.478.86.0.Pr , Hose For Dv8 Air Cleaner Cart Part No Dv8.505.04.0.00 , Hose For Dv8 At Turbo End 8240405 Cart Part No Dv8.505.08.0.00 , Hose Between Air Cleaner Pipe Cart Part No Dv8.505.28.0.Pr , Air Cleaner Kit Cart Part No Dv8.505.30.0.00 , Hose: Air Cleaner Cart Part No Dv8.505.71.0.00 , Rain Cap Clamp Cart Part No Dv8.505.72.0.00 , Air Cleaner Primary Element Cart Part No Dv8.505.74.0.00 , Air Cleaner Safety Element Cart Part No Dv8.505.75.0.00 , Hose: Air Cleaner Cart Part No Dv8.505.76.0.00 , Air Cleaner Assly+Safety Elemt Cart Part No Dv8.505.80.0.00 , Fuel Pipe: Fuel Tank To Leak Off Pipe Cart Part No Dv8.507.02.0.00 , Fuel Pipe: Fuel Tank To Fuel Filter Cart Part No Dv8.507.03.0.00 , Fuel Inlet Pipe Cart Part No Dv8.507.06.0.00 , Fuel Pipe From Pre Filter To Tank Cart Part No Dv8.507.22.0.Pr , Fuel Pipe Cart Part No Dv8.507.23.0.Pr , Fuel Return Pipe M16x1 5 To M22x1 5 Cart Part No Dv8.507.24.0.Pr , Fuel Return Pipe (M16x1.5 Male Plug And M22x1.5 Union Nut) Cart Part No Dv8.507.26.0.Pr , Vent Pipem14 X1 5 Union Nut Both Side Cart Part No Dv8.560.01.0.Pr , Koel Green Alternatorkg400 S T Framel Kg 47 2 Vs3sae 1 14 415V50 Hz Cart Part No Dv8.801.21.0.00 , Koel Green Ls Ag316294 Alternator 320Kva Kg45c Sae 1 14 415V 50Hz Cart Part No Dv8.801.24.0.Pr , Koel Green Alternator Kg320 St Frame Mkg38 2 5L4asae 1 14 415V50hz0 8 Pf Cart Part No Dv8.801.25.0.Pr , Koel Green Alternator, Kg 380 Ss, Framekg 47.2 Vs2 Sae1/14, 415V, 50Hz Cart Part No Dv8.801.32.0.00 , Level Tube With Switch Cart Part No Dv8.803.114.0.Pr , Adblue Pipe 1 Supply Module To Dosing Module Bank A Cart Part No Dv8.803.154.0.Pr , Adblue Pipe 2 Supply Module To Dosing Module Bank A B Cart Part No Dv8.803.155.0.Pr , Adblue Pipe 3 Supply Module To Dosing Module Bank A Cart Part No Dv8.803.156.0.Pr , Adblue Pipe 1 Supply Module To Dosing Module Bank B Cart Part No Dv8.803.159.0.Pr , Adblue Pipe 3 Supply Module To Dosing Module Bank B Cart Part No Dv8.803.160.0.Pr , Adblue Day Tank Cart Part No Dv8.803.185.0.Pr , Adblue Piping Assy Day Tank Inlet Cart Part No Dv8.803.187.0.Pr , Fuel Flow Meter (Differential) For Rdso Dv8 500Kva Cpcb Iv+ Cart Part No Dv8.803.21.0.Pr , Isolation Valve Assyfor Adblue Day Tank Out Cart Part No Dv8.803.222.0.Pr , Flexible Hosesuitable For Adblue 32Aus Cart Part No Dv8.803.223.0.Pr , Mechanical Level Tubefor Adblue Cart Part No Dv8.803.305.0.Pr , Fuel Pipe From Coach Tank To To Fuel Pre Filter Cart Part No Dv8.803.41.0.Pr , Fuel Pipe From Pre Filter To Fuel Flow Meter (Suction) Cart Part No Dv8.803.42.0.Pr , Fuel Pipe From Flow Meter To Coach Tank Return Cart Part No Dv8.803.43.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 1 Lhs From F W E Cart Part No Dv8.803.62.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 1 Rhs From F W E Cart Part No Dv8.803.67.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 2 Rhs From F W E Cart Part No Dv8.803.68.0.Pr , Adblue Pipesupply Module Out To Dosing Module In 2 Lhs From F W E Cart Part No Dv8.803.69.0.Pr , Metallic Pipe Fuel Flow Meter Out To Main Filter (Suction) Cart Part No Dv8.803.85.0.Pr , Fuel Pipe Return To Fuel Flow Meter Return Cart Part No Dv8.803.87.0.Pr , Exhaust Pipebellow To Catcon Cart Part No Dv8.806.103.0.Pr , Adaptor (M14 X 1.5 Both Side) Cart Part No Dv8.806.97.0.Pr , Adaptorm16 X 1 5 And M20 X 1 5 Cart Part No Dv8.806.98.0.Pr , Wet Pm Kit(W/O Oil) For Dv8.8301,Dv8.9207 Cart Part No Dv8.830.1.0.Sp , Control Panel Assembly For Fire Fighting Application Cart Part No Dv8.851.10.0.Pr , Engine Wiring Harness Assembly For Dv8 Fire Fighting Application Cart Part No Dv8.852.10.0.00 , 1500 Hrs C Check Maintenance Kit Dv8 8501 C4dv8 8542 C4 Cart Part No Dv8.854.01.0.Sp , Engine Control Panel To Alternator Control Harness Cart Part No Dv8.854.20.0.Pr , Control Panel Assembly For Dv8ta Cpcb4+ Cart Part No Dv8.854.30.0.Pr , 320Kva Avr (Dslr) Cart Part No Dv8.856.19.0.00 , Control Panel Stand Cart Part No Dv8.856.31.0.Pr , Adv Load Dump Module 24Vdc Cart Part No Dv8.858.16.0.00 , Engine Control Panel Assembly Sf Kg 745 Unit & 4-20 Ma Lop Cart Part No Dv8.866.10.0.00 , Engine Control Panel Assembly Sf Kg 745 Unit & 4-20 Ma Lop Cart Part No Dv8.867.10.0.00 , Engine Controlpanel Assembly Cart Part No Dv8.867.50.0.00 , Control Panel Assembly For Dv Series Cpcb4 Cart Part No Dv8.868.70.0.Pr , Interface Box Assembly Cart Part No Dv8.868.80.0.Pr , Interface Box Assembly Cart Part No Dv8.869.10.0.Pr , Cold Start Kit Main Assembly For L2 Level Application(24V System) Dv8 500Kva Cart Part No Dv8.870.50.0.Sp , Silencer For Dv8 320 Kvaproject Lakshya Cart Part No Dv8.875.21.0.Pr , Avr R450-Kg 47.2,Kva Rating-380 To 1010 Kva ,3Ph Cart Part No Dv8.901.01.0.Asp , Coupling Disc14kg 47 2 Kva Rating 380 To 600Kva3ph Cart Part No Dv8.901.13.0.Asp , Assembly For 3 Pin Male Connector Cart Part No Dv8.903.09.0.00 , Engine Wiring Harness Dv8 Rdso Engine Ecu Chamber 2 3 4 For Cpcb4 Cart Part No Dv8.906.03.0.Pr , Engine Wiring Harness Dv8 Rdso Engine Ecu Chamber 1 For Cpcb4 Cart Part No Dv8.906.04.0.Pr , Engine Wiring Harness Dv8 Rdso Engine Ecu Chamber 8 For Cpcb4 Cart Part No Dv8.906.06.0.Pr , Air Heater Wiring Harness Cart Part No Dv8.906.36.0.Pr , Interface Box Assembly For Rdso Cart Part No Dv8.906.61.0.Pr , Rdso Ewh Ecu Chamber 5 6 7 Cart Part No Dv8.906.74.0.Pr , Dcu Wiring Harness For Dv8 Rdso Cart Part No Dv8.906.76.0.Pr , A057e698mdl Ovm 3Ph Cart Part No Dv8.906.92.0.00 , Avr Cart Part No Dv8.906.93.0.00 , Engine Wiring Harness Assemblyfor Dv8 Engine With Kg545 Unit With Conector Cart Part No Dv8.910.20.0.00 , Engine Wiring Harness Assemblyfor Dv8 Engine With Kg545 Unit 4 20 Ma Gems Lop Cart Part No Dv8.910.50.0.00 , Engine Wiring Harness Assembly Cart Part No Dv8.910.60.0.00 , Engine Wiring Harness Assembly Cart Part No Dv8.910.70.0.00 , Cold Starting Wiring Harness For Dv8 Genset Cart Part No Dv8.910.90.0.Pr , Engine Harness Master Ecu To Sensors For Dv8 250Kva Png Genset Cart Part No Dv8.913.50.0.Pr , Engine Harness Slave Ecu To Sensors For Dv8 250Kva Png Genset Cart Part No Dv8.913.60.0.Pr , Engine Harness Master Ecu To Sensors For Dv8 250Kva Png Genset (Cpcb4+) Cart Part No Dv8.913.70.0.Pr , Engine Harness Slave Ecu To Sensors For Dv8 250Kva Png Genset (Cpcb4+) Cart Part No Dv8.913.80.0.Pr , Wet Pm Kit (W/O Oil) For Dv8.9214, Dv8.9306 - Dv8 Cart Part No Dv8.921.04.0.Sp , Coupling Element Cart Part No Dv8.991.35.1.Sp , Coupling Cart Part No Dv8.991.36.0.Pr , Wet Pm Kit (W/O Oil) For Dv8.1045... - Dv8 Cart Part No Dv8.999.02.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.1501, Dv8.9207, Dv8.8301 - Dv8 Sr2 Cart Part No Dv8.999.14.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.1223 - Dv8.Sr1 Cart Part No Dv8.999.15.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.1201 - Dv8 Sr1 Cart Part No Dv8.999.16.0.Sp , Solenoid Valve For 125/250Kva Cart Part No Dv8.999.71.0.Sp , Pressure Regulator First Level For 250 Kvar 5201 Vi Cart Part No Dv8.999.73.0.Sp , Pressure Gauge0 1600 Mmwcstub Size 3 8Bsp Cart Part No Dv8.999.74.0.Sp , Filter Assembly 1? Bsp(F) (F0112 Iii) Cart Part No Dv8.999.76.0.Sp , Filter Service Kit (Consisting Of O Ring & Filter Mesh) (F0112 Iii K) Cart Part No Dv8.999.77.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.8101 - Dv8ta G1 Cart Part No Dv8.999.86.0.Sp , Wet Pm Kit (W/O Oil) For Dv8.9306...,Dv8.8308...,Dv8.8206...,Dv8.9214..., Dv0.9018... - Dv10 Cart Part No Dv8.999.93.0.Sp , Wet Pm Kit (W/O Oil ) For Dv8.8501.C4 Cart Part No Dv8.999.94.0.Sp , Exhaust Temp Sensor T6 Before Mixer For Cpcb4 Cart Part No Dv8.Egt4.28.0.Pr , Main Bearing Pair Grooved Ra3 Cart Part No F.038.4.01.003 , Main Bearing Pair Grooved Ra3 Cart Part No F.038.4.01.013 , Main Bearing 020 O/S Pair Cart Part No F.038.4.01.023 , Main Bearing: Ha394 Cart Part No F.073.4.00.003 , Main Bearing: Ha394 Cart Part No F.073.4.00.013 , Main Bearing: Ha394 Cart Part No F.073.4.00.023 , Main Bearing 030 O/S Cart Part No F.073.4.00.033 , Main Bearing Pair Cart Part No F.547.4.00.003 , Dowel (Din 1472-6X18-St)Or Grooved Pins Cart Part No F6.001.07.0.00 , Oil Spray Assembly Cart Part No F6.001.103.0.00 , Oil Spray Assembly Cart Part No F6.001.104.0.00 , Pressure Reducing Nozzle Cart Part No F6.001.24.0.00 , Intermediate Gear(For Oil Pump) Cart Part No F6.001.26.0.00 , Intermediate Shaft Cart Part No F6.001.27.0.00 , Plate Cover For Rear Side Cart Part No F6.001.28.0.00 , Ball Bearing Cart Part No F6.001.29.0.00 , Spacer(20X28x1-Din 988) Cart Part No F6.001.30.0.00 , Relief Valve Assly Cart Part No F6.001.31.0.00 , Taper Spacer. Cart Part No F6.001.38.0.00 , Hub Cart Part No F6.001.44.0.00 , Back Plate Cart Part No F6.001.45.0.00 , Sealing Cap (26 Din 443) Cart Part No F6.001.54.0.00 , Dowel (10X32 Din1474)Grooved Pins Cart Part No F6.001.57.0.00 , Sealing Cap Cart Part No F6.001.58.0.00 , Intermediate Mediate Gear With Bush Cart Part No F6.001.66.0.00 , Banjo Bolt: M12x1.5 Cart Part No F6.001.87.0.00 , Sealing Cap Cart Part No F6.001.91.0.00 , Joint: Front Plate Cart Part No F6.002.02.0.00 , Front Plate Cart Part No F6.002.06.0.00 , Dowel Cart Part No F6.003.04.0.00 , Deflector Cart Part No F6.003.05.0.00 , Socket Head Screw(Din 912 M16x50-10.9) Cart Part No F6.003.06.0.00 , Deflector For Fwe Oil Seal Cart Part No F6.003.09.0.00 , Crankshaft Gear Cart Part No F6.003.11.0.00 , Camshaft Gear Cart Part No F6.004.03.0.00 , Spinon Filter Assly Cart Part No F6.004.09.0.00 , Tappet Cart Part No F6.004.14.0.00 , Push Rod Assly Cart Part No F6.004.40.0.00 , Fuel Filter & Water Seperator Cart Part No F6.004.58.0.00 , Connecting Rod Bolt Cart Part No F6.005.02.0.00 , Piston Pin Cart Part No F6.005.12.0.00 , Connecting Rod Assly Cart Part No F6.005.30.0.00 , Piston Ring Set (Std.) Cart Part No F6.005.71.0.00 , Rubber Ring Cart Part No F6.006.02.0.00 , Sealing Ring: Bottom Cart Part No F6.006.03.0.00 , Valve Guide Cart Part No F6.007.02.0.00 , Valve Seat Insert Inlet Cart Part No F6.007.03.0.00 , Valve Seat Insert Exhaust Cart Part No F6.007.04.0.00 , Valve Collet Pair Cart Part No F6.007.07.0.00 , Valve Spring Cup Cart Part No F6.007.08.0.00 , Valve Spring -Outer Cart Part No F6.007.09.0.00 , Socket Head Bolt For Cylinder Head (M12x1.75X140 - Grade 12.9) Cart Part No F6.007.101.0.00 , Valve Spring (Inner) Cart Part No F6.007.11.0.00 , Washer Cart Part No F6.007.12.0.00 , Washer Cart Part No F6.007.13.0.00 , Valve Seal Cart Part No F6.007.14.0.00 , Rocker Support Sub Assembly Cart Part No F6.007.15.0.00 , Ball Screw Cart Part No F6.007.19.0.00 , Lever Clamp Cart Part No F6.007.21.0.00 , Cylinder Head Bolt: Long Cart Part No F6.007.22.0.00 , Cylinder Head Bolt: Short Cart Part No F6.007.23.0.00 , Cyl Head Gasket 1.25 Mm Thk Cart Part No F6.007.26.0.00 , Banjo Bolt :M8x1 Cart Part No F6.007.31.0.00 , Straight Thr Socket Cart Part No F6.007.33.0.00 , Sealing Cap Cart Part No F6.007.34.0.00 , Sealing Cap Cart Part No F6.007.35.0.00 , Oil Supply Pipe Assly Cart Part No F6.007.40.0.00 , Valve Pair Inlet & Exhaust Cart Part No F6.007.55.0.00 , V.R. Lever & Bush Assly Cart Part No F6.007.60.0.00 , Cyl Head Gasket 1.25 Mm Thk Cart Part No F6.007.96.0.00 , Cylinder Head Gasket Cart Part No F6.007.98.0.00 , Washer Cart Part No F6.007.99.0.00 , Rocker Cover Cart Part No F6.008.01.0.00 , Joint: Rocker Cover Cart Part No F6.008.02.0.00 , Threaded Bush Cart Part No F6.009.04.0.00 , Oil Seal: 100X75x10 Teflon Ge Cart Part No F6.009.16.0.00 , O Ring: Id 65 Dia 5 - 21516 Cart Part No F6.009.27.0.00 , Joint: Suction Connection Cart Part No F6.009.39.0.00 , Dipstick Assembly Cart Part No F6.011.01.0.00 , O Ring: Dipstick 7X2 Tgl 6365 - 21511 Cart Part No F6.011.04.0.00 , Dipstick Asm Cart Part No F6.011.60.0.Pr , Lube Oil Sump: Sheet Metal Cart Part No F6.012.01.0.00 , Breather Housing Cart Part No F6.013.01.0.00 , Pipe Cart Part No F6.013.02.0.00 , Venting Pot Cart Part No F6.013.04.0.00 , Outlet Pipe Cart Part No F6.013.11.0.00 , O Ring: 30 Id Dia 2- 21509 Cart Part No F6.013.12.0.00 , Rubber Hoses: 40Lg Cart Part No F6.013.13.0.00 , Hose Cart Part No F6.013.22.0.00 , Crank Pulley.(Finish.) Cart Part No F6.015.01.0.00 , Driven Hub Cart Part No F6.015.02.0.00 , Damper Cart Part No F6.015.03.0.00 , Thrust Plate Cart Part No F6.015.04.0.00 , Hex Bolt For Crank-Pulley Cart Part No F6.015.07.0.00 , Crank Pulley Pcd 155, Pcd 210 Cart Part No F6.015.31.0.00 , Rubber Cap Cart Part No F6.016.12.0.00 , Oil Seal: 150X120x13.5 Teflon Fwe Cart Part No F6.016.16.0.00 , Shaft Cart Part No F6.017.02.0.00 , Pulley Cart Part No F6.017.03.0.00 , Bracket For Fan Pulley Mounting Cart Part No F6.017.17.0.00 , Ball Bearing(Din 625-6306-2Rs1) Cart Part No F6.017.21.0.00 , Pulley Assly: Fan Drive Cart Part No F6.017.30.0.00 , Fan Pulley Poly V Pcd 155 Cart Part No F6.017.31.0.00 , Fan Drive Pulley Assly Cart Part No F6.017.50.0.Pr , Bracket Cart Part No F6.018.01.0.00 , Pulley Cart Part No F6.018.05.0.00 , Deep Groove Ball Bearing Cart Part No F6.018.14.0.00 , Eye Bolt Cart Part No F6.018.19.0.00 , Belt Tensioning Unit Assembly Cart Part No F6.018.20.0.00 , Swivel Piece Cart Part No F6.018.21.0.00 , Adaptor Cart Part No F6.018.22.0.00 , Bracket: Pulley Assly Cart Part No F6.018.30.0.00 , Belt Tension Pulley Pcd 90 Cart Part No F6.018.31.0.00 , Belt Tensioning Unit Assly Cart Part No F6.018.40.0.00 , V-Belt (Avx 13 X 1562 L) Cart Part No F6.019.16.0.00 , V Belt: Avx13 X 1015 Length Cart Part No F6.019.17.0.00 , Pump Driving Gear Cart Part No F6.021.11.0.00 , O Ring 28X5 Tgl 6365 -21509 Cart Part No F6.021.15.0.00 , Rubber Boot Cart Part No F6.022.05.0.00 , Gasket. Cart Part No F6.022.08.0.00 , Suction Tube Cart Part No F6.022.20.0.00 , Pipe Sub Assembly Cart Part No F6.023.20.0.00 , Threaded Adaptor Cart Part No F6.024.03.0.00 , Joint: Centrifuge Cleaner Cart Part No F6.024.07.0.00 , Joint For Lub Oil Filter Header Cart Part No F6.024.103.0.00 , O Ringid 20 Dia 2 Mat 21516 Cart Part No F6.024.17.0.00 , Relief Valve Assly Cart Part No F6.024.40.0.00 , Centrifuge Filter Cart Part No F6.024.46.0.00 , O Ring: Drain Plug Cart Part No F6.024.47.0.00 , Assembly Of Lube Oil Filter & Header Cart Part No F6.024.50.0.00 , Lube Oil Filter Header Cart Part No F6.024.74.0.00 , Joint: Glacier Filter Cart Part No F6.024.75.0.00 , Joint: Oil Return Turbo Cart Part No F6.024.77.0.00 , Gasket For Crankcase Breather) Cart Part No F6.024.78.0.00 , Joint Cart Part No F6.024.81.0.00 , Joint: Special Adaptor Piece Cart Part No F6.024.82.0.00 , Joint Cart Part No F6.024.83.0.00 , Joint: Water Pump Cart Part No F6.024.85.0.00 , Joint: Delivery Pipe Cart Part No F6.024.86.0.00 , Joint: Cooler Box Cart Part No F6.024.88.0.00 , Joint: Header Cart Part No F6.024.91.0.00 , Joint: Oil Sump Cart Part No F6.024.93.0.00 , Joint: Flange Cart Part No F6.024.94.0.00 , Joint: Flywheel Housing Cart Part No F6.024.95.0.00 , Joint: Front Plate Cart Part No F6.024.96.0.00 , Joint: Gear Casing Cart Part No F6.024.97.0.00 , Joint: Inlet Manifold Cart Part No F6.024.98.0.00 , Charge Air Manifold Cart Part No F6.025.07.0.00 , Joint: Exhaust Manifold Cart Part No F6.026.03.0.00 , Spacer Sleeve Cart Part No F6.026.04.0.00 , Gasket For Exhaust Manifold Cart Part No F6.026.06.0.00 , Starter Sm 130Pe Cart Part No F6.028.01.0.00 , Flange Cart Part No F6.029.01.0.00 , Adaptor Cart Part No F6.029.02.0.00 , Fuel Pump Cart Part No F6.029.10.0.00 , Fuel Pump Gear Cart Part No F6.029.101.0.Pr , Adaptor Cart Part No F6.029.102.0.Pr , Housing Cart Part No F6.029.103.0.Pr , Shaft Distributor Drive Cart Part No F6.029.104.0.Pr , Cam Tone Wheel Adaptor Cart Part No F6.029.105.0.Pr , Joint (Between Housing & Flange) Cart Part No F6.029.106.0.Pr , Cover Plate For Housing Cart Part No F6.029.107.0.Pr , Clamping Nutfor Pump Cart Part No F6.029.18.0.00 , Lube Oil Supply Pipe(Crank Case To Fuel Pump) Cart Part No F6.029.19.0.00 , Intermediate Flange Assembly Cart Part No F6.029.20.0.00 , Fuel Pump Gear Cart Part No F6.029.92.0.00 , Pipe Assembly Cart Part No F6.030.10.0.00 , High Press Pipe Assly Cart Part No F6.030.40.0.00 , Cup Seal Cart Part No F6.031.02.0.00 , Fork For Injector Cart Part No F6.031.03.0.00 , Speherical Washer Cart Part No F6.031.05.0.00 , Injector Cart Part No F6.031.07.0.00 , Sealing Washer[2 916 710 602] Cart Part No F6.031.51.0.00 , Banjo Bolt: Hollow Bolt Cart Part No F6.032.05.0.00 , Vent Pipe Sub Assly Cart Part No F6.032.20.0.00 , Sub Assly Of Vent Tube Cart Part No F6.032.40.0.00 , Vent Tube Assembly Cart Part No F6.032.70.0.00 , Bracket For Fuel Filter Cart Part No F6.034.06.0.00 , Fuel Pipe: Feed Pump To Fuel Filter Cart Part No F6.034.08.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No F6.034.11.0.00 , Fuel Pipe: Fuel Filter To Fip Cart Part No F6.034.12.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No F6.034.14.0.00 , Lube Oil Cooler -Plate Type Cart Part No F6.036.01.0.00 , Water Drain Plug Cart Part No F6.036.06.0.00 , Joint: Lube Oil Cooler Cart Part No F6.036.11.0.00 , Sealing Washer Cart Part No F6.040.01.0.00 , Rocker Cover Cart Part No F6.040.03.0.00 , Oil Filler Cap Cart Part No F6.040.04.0.00 , Oil Filler Capplastic Cart Part No F6.040.05.0.00 , Injector Cart Part No F6.042.31.0.00 , Leak Off Pipe Assembly Cart Part No F6.043.10.0.00 , Leak Off Pipe With Flex Element Cart Part No F6.043.20.0.00 , Flywheel Housing Cart Part No F6.044.01.0.00 , Joint For Front Plate4v Common Rail Cart Part No F6.046.04.0.Pr , Pigtail For Lop Sensor Cart Part No F6.046.115.0.Pr , Pigtail For Vdo Sensor Cart Part No F6.046.116.0.Pr , Adaptor For Water Temp Sensor Cart Part No F6.063.71.0.00 , Charging Alternator Cart Part No F6.063.74.0.00 , Hose For Drain Pump Out Cart Part No F6.064.52.0.00 , V Belt: 4Pk1280 Poly Cart Part No F6.064.95.0.00 , Hose: Air Cleaner Cart Part No F6.065.27.0.00 , Drain Pipe Cart Part No F6.065.38.0.00 , Flywheel Housing Cart Part No F6.073.25.0.00 , Gas Train Assly Cart Part No F6.086.25.0.Pr , Exhaust Manifold Lagging Sl90 Cart Part No F6.086.39.0.Pr , Woodward Trim Down Pg Plus System For 6 Cylinder Natural Gas Genset Cart Part No F6.086.50.0.Pr , 3 Way Single Brick Catcon For Sl90 Png 40 Gm Ft3 Loading With Insulation 5 0 1 Cart Part No F6.086.58.0.Pr , Hoserocker Cover To Ccv Cart Part No F6.086.88.0.Pr , Pipe(Cac To Inlet Manifold) Cart Part No F6.1002.08.0.00 , Joint For Inlet Manifold Cart Part No F6.1002.15.0.00 , Inlet Manifold Cart Part No F6.1002.27.0.Pr , Copper Washerfor Spark Plug Thickness 0 5 Mm Cart Part No F6.1002.32.0.Pr , Copper Washerfor Spark Plug Thickness 0 8 Mm Cart Part No F6.1002.33.0.Pr , Copper Washerfor Spark Plug Thickness 1 Mm Cart Part No F6.1002.34.0.Pr , Governor Card Cart Part No F6.1005.01.0.00 , Converter Cable Cart Part No F6.1005.04.0.00 , Wiring Harness Assly: 250Kva Cart Part No F6.1020.10.0.00 , Engine Wiring Harness With Kg 54 Unit Cart Part No F6.1020.40.0.00 , Engine Wiring Harness Sf Kg545 Unit With Elect. Gov And 4-20Ma Lop Transmitter Cart Part No F6.1020.50.0.00 , Engine Wiring Harness Assembly With Kg545 Unit Cart Part No F6.1020.70.0.00 , Engine Wiring Harness Assembly With Kg545 Unit Cart Part No F6.1020.80.0.00 , Alternator To Control Panel Wiring Harness Cart Part No F6.1024.10.0.00 , Koel Green Alternator,320Kva,Frame Kg 45 C,Sae1/14,415V,50Hz,0.8Pf,High Efficienc Cart Part No F6.1025.05.0.Pr , Engine Control Panel Sf Png Sl90 Engine With Woodward Ecu Kg645 Controller Cart Part No F6.1034.60.0.Pr , Engine Wiring Harness Assemblywith 16 Pin Conn.(Dse 6120 Mkii Unit) Cart Part No F6.1035.10.0.00 , Engine Wiring Harness For 125Kva Biogas Genset Cart Part No F6.1040.50.0.Pr , Engine Wiring Harness Sf Sl90 Png (125Kva) Cart Part No F6.1040.80.0.Pr , Control Panel Assembly S/F 200/250Kva Cart Part No F6.1041.50.0.00 , Engine Wiring Harness For Sl90 Crdi Cpcb4+ Cart Part No F6.1043.10.0.Pr , Engine Wiring Harness For Sl90 320Kva Cpcb 4+ Cart Part No F6.1043.20.0.Pr , Engine Wiring Harness For Sl90 320Kva Cpcb Iv Engine Cart Part No F6.1043.80.0.Pr , Engine Wiring Harness For Sl90 Crdi Cpcb Iv For Genset A Cart Part No F6.1051.10.0.Pr , Engine Wiring Harness For Sl90 Crdi Cpcb Iv For Genset B Cart Part No F6.1051.20.0.Pr , Canopy Wiring Harness For Sl90 640Kva(2X320kva) Cpcb Iv Cart Part No F6.1051.30.0.Pr , Engine Control Panel To Alternator Ct Harness For Genset A Cart Part No F6.1051.40.0.Pr , Engine Control Panel To Alternator Ct Harness For Genset B Cart Part No F6.1051.50.0.Pr , Fip: 200Kva C Type Lever Cart Part No F6.1101.01.0.00 , Cooling Line 1 1 4 24Vassly For Kfp6s Uf35 Sl90taengines S F Flow Switch For Fi Cart Part No F6.1106.40.0.Pr , Cooling Line Assembly (1 1/4, 24V) Cart Part No F6.1106.60.0.00 , Cylinder Head Sub Assly Cart Part No F6.111.20.0.00 , H Ppipe Assly Cyl No 1 Sl90 4Vcommon Rail Cart Part No F6.1127.10.0.Pr , H Ppipe Assly Cyl No 2 Sl90 4Vcommon Rail Cart Part No F6.1127.20.0.Pr , H Ppipe Assly Cyl No 3 Sl90 4Vcommon Rail Cart Part No F6.1127.30.0.Pr , H Ppipe Assly Cyl No 4 Sl90 4Vcommon Rail Cart Part No F6.1127.40.0.Pr , H Ppipe Assly Cyl No 5 Sl90 4Vcommon Rail Cart Part No F6.1127.50.0.Pr , H Ppipe Assly Cyl No 6 Sl90 4Vcommon Rail Cart Part No F6.1127.60.0.Pr , H P Pipe Assembly 1Pump To Railsl90 4V Cart Part No F6.1127.70.0.Pr , H P Pipe Assembly 2Pump To Railsl90 4V Cart Part No F6.1127.80.0.Pr , Suction Connection For Fire Fighting Cart Part No F6.121.02.0.00 , Silencer Cart Part No F6.123.02.0.00 , Silencer Cart Part No F6.123.03.0.00 , Flange Cart Part No F6.123.06.0.00 , Anti Vibration Mounts Cart Part No F6.126.02.0.00 , Breather Pipe(Moduled Rubber Hose With Reinforcement Plies ) For 160 & 250 Kva Cart Part No F6.138.01.0.00 , Breather Hose Cart Part No F6.138.02.0.00 , Hose For Gas Inlet To Mixer Cart Part No F6.138.05.0.Pr , Breather Hose (From Engine Breather To Pipe) Cart Part No F6.138.06.0.Pr , Pipe For Air Cleaner Cart Part No F6.138.13.0.Pr , Joint: Exhaust Silencer Cart Part No F6.149.02.0.00 , Flange Cart Part No F6.149.03.0.00 , Radiator Cart Part No F6.150.01.0.Sp , Stay For Radiator Cart Part No F6.150.02.0.00 , Hose Cart Part No F6.150.03.0.00 , Pipe: Thermostat To Radiator Cart Part No F6.150.04.0.00 , Fan Spacer Cart Part No F6.150.06.0.00 , Hose: Water Out Cart Part No F6.150.13.0.00 , Hose: Radiator To Water Pump Cart Part No F6.150.17.0.00 , Aluminium Radiator Assembly For 200 Kva Cart Part No F6.150.91.0.Pr , Union Adoptor Cart Part No F6.151.02.0.00 , Gear With Bearings Cart Part No F6.151.26.0.00 , Piston Assembly Cart Part No F6.153.20.0.00 , Cyl Liner Assembly Cart Part No F6.154.10.0.00 , Cylinder Head Sub Assembly Cart Part No F6.155.20.0.00 , Cylinder Head Subassembly Cart Part No F6.155.30.0.Pr , Thermostat Cover: Finish Cart Part No F6.156.03.0.00 , Joint For Blanking Plate(Non Asbestos) Cart Part No F6.156.42.0.00 , Cover Plate Cart Part No F6.156.43.0.00 , Joint: Thermostat Cover & Gear Casing Cart Part No F6.156.44.0.00 , Gear Casing: Cast Iron Cart Part No F6.156.45.0.00 , Shim For Speed Phase Sensor Cart Part No F6.156.59.0.Pr , Shim For Speed Phase Sensor Cart Part No F6.156.61.0.Pr , Shimfor Speed Phase Sensors Cart Part No F6.156.62.0.Pr , Cylinder Head Assly Cart Part No F6.157.10.0.00 , Rocker Support Assembly Cart Part No F6.157.50.0.00 , Water Pump Sub Assly Cart Part No F6.164.20.0.00 , Charged Air Manifold (Finish.) Cart Part No F6.167.02.0.00 , O Ring.(68X3 Tgl 6365)Co.Std.21509 Cart Part No F6.167.03.0.00 , Bend Engine Side Cart Part No F6.167.06.0.00 , O Ring: 90X3 Tgl 6365- 21509 Cart Part No F6.167.14.0.00 , R Rings: 65X2.5 Cart Part No F6.168.02.0.00 , Cold Starting Kit For Sl90 200 Kva And 250 Kva L1 To L3 Cart Part No F6.1684.90.0.00 , Oil Return Adaptor Cart Part No F6.169.02.0.00 , Pipe Cart Part No F6.169.03.0.00 , Flange Engine Side Cart Part No F6.169.04.0.00 , Hose: Turbocharger Air Outlet Cart Part No F6.169.09.0.00 , O Ring: 22 Id Dia5 - 21509 Cart Part No F6.169.15.0.00 , Oil Supply Pipe Sub Assly (For T/C) Cart Part No F6.169.20.0.00 , Joint For Oil Return Pipe Crankcase Side Cart Part No F6.169.21.0.00 , Joint For Oil Return Pipe Turbocharger (Non Asbestos) Cart Part No F6.169.31.0.00 , Joint For Oil Supply Turbocharger (Non Asbestos) Cart Part No F6.169.32.0.00 , Gasket For Oil Return Pipe Turbo Charger(Non Asbestos) Cart Part No F6.169.33.0.00 , Exhaust Mfold: Lh Piece Cart Part No F6.177.01.0.00 , Exhaust Manifold (Rh) Cart Part No F6.177.02.0.00 , Exhaust Mfold: Central Open Cart Part No F6.177.03.0.00 , T/C L.O.Drain Connector: Ccase Cart Part No F6.177.11.0.00 , Lube Oil Drain Connector Cart Part No F6.177.12.0.00 , Spacer Sleeve (Copper Coated) Cart Part No F6.177.13.0.00 , Exhaust Manifoldleft Side Cart Part No F6.177.22.0.Pr , Exhaust Manifold R H Side Cart Part No F6.177.23.0.Pr , Exhaust Manifoldcentral Opening Cart Part No F6.177.24.0.Pr , Clampfor Turbo Oil Inlet Pipe Cart Part No F6.177.29.0.00 , Rubber Sleeve Cart Part No F6.177.31.0.00 , Spacer (For Turbocharger Oil Supply Pipe) Cart Part No F6.177.32.0.00 , Oil Supply Pipe Sub Assembly ( With Flex. Member ) Cart Part No F6.177.40.0.00 , Oil Supply Pipe Sub Assly (With Flex Member ) Cart Part No F6.177.50.0.00 , Lube Oil Pump: High Discharg Cart Part No F6.178.10.0.00 , Lube Oil Pump Cart Part No F6.178.50.0.00 , Crankcase Assly Cart Part No F6.182.100.0.00 , Crankcase Assly. (With 7 Bolt) (F6.182.110.0.Pr) Cart Part No F6.182.110.0.Sp , Crankcase Assembly (With Main Bearing Cap & Sealing Cap) (F6.182.130.0.Pr) Cart Part No F6.182.130.0.Sp , Piston Cooling Nozzle Cart Part No F6.182.34.0.Pr , Crankcase Assembly Cart Part No F6.182.90.0.Sp , V Belt: 4Pk-1570 Poly Cart Part No F6.184.01.0.00 , V Belt: 8Pk 983 Poly Cart Part No F6.184.02.0.00 , Poly V Belt 8Pk:1065 Cart Part No F6.184.03.0.00 , Poly V Belt 4Pk: 1515 Cart Part No F6.184.04.0.00 , Poly V Belt - 9Pk-1214 Cart Part No F6.184.07.0.Pr , Poly V Belt - 4Pk-1280 Cart Part No F6.184.08.0.Pr , Exhaust Pipe With Bellow (Turbo Outlet To Egt Inlet) Cart Part No F6.187.103.0.Pr , 36Wing Fan For Sl90 Cpcb4application Cart Part No F6.187.104.0.Pr , Gasketfor Dosing Module Cart Part No F6.187.112.0.Pr , Joint (12 Egt Inlet) Cart Part No F6.187.12.0.Pr , Joint (12 Egt Outlet) Cart Part No F6.187.13.0.Pr , Fan: 34 Plastic Cart Part No F6.187.15.0.00 , Adblue Tank Clamp (45 Lit) Cart Part No F6.187.18.0.Pr , 45L Ad Blue Tank Assembly Cpcb4 Cart Part No F6.187.19.0.Pr , Radiator Fan (36) Cart Part No F6.187.22.0.00 , 12Egt Clamp Cart Part No F6.187.27.0.Pr , Rubber Sleeve For Tank Clamp Cart Part No F6.187.29.0.Pr , Radiator Cart Part No F6.187.70.0.00 , Fan Spacer Cart Part No F6.187.71.0.Pr , Hose Between Pump Inlet And Radiator Pipe Outlet Cart Part No F6.187.72.0.Pr , Radiator Outlet Hose Cart Part No F6.187.74.0.Pr , Aluminium Radiator Assembly Cart Part No F6.187.75.0.Pr , Radiator Fan 36 Cart Part No F6.187.79.0.Pr , Exhaust Pipe With Bellow Turbo To Egt Inlet Cart Part No F6.187.85.0.Pr , Anti Vibration Mount For Radiator Cart Part No F6.187.92.0.Pr , Radiator Outlet Hose Cart Part No F6.187.96.0.Pr , Shaft For Fan Pulley Cart Part No F6.192.04.0.00 , Bracket For Fan Pulley Mounting 250 Kva Cart Part No F6.192.05.0.00 , Ball Bearing Cart Part No F6.192.07.0.00 , V Belt: Cogged Bx40-1060 Cart Part No F6.192.11.0.00 , Bracket Subassemblys F Fan Mounting Cart Part No F6.192.20.0.00 , Fan Pulley Pcd 160 Cart Part No F6.192.21.0.00 , Fan Pulley Assembly Cart Part No F6.192.30.0.00 , Fan Pulley Assembly Cart Part No F6.192.51.0.00 , Belt Tensioning Unit Assly Cart Part No F6.193.20.0.00 , Belt Tension Unit Assembly Cart Part No F6.193.30.0.00 , Joint: Exh Silencer Cart Part No F6.201.02.0.00 , Joint For Thermostat Cover Cart Part No F6.241.02.0.Pr , Jointbetwater Pump Crankcase Cart Part No F6.241.03.0.Pr , Water Pump Assembly Cart Part No F6.241.10.0.Pr , Bearing Housing (For Fan Drive) (4V Common Rail) Cart Part No F6.243.02.0.00 , Shaft Cart Part No F6.243.03.0.Pr , Fan Pulleyfinish Cart Part No F6.243.04.0.Pr , Fan Drive Assembly4v Common Rail Cart Part No F6.243.10.0.Pr , Joint Between Adaptor Front Plate4v Common Rail Cart Part No F6.244.04.0.Pr , External Spline Hub For Fuel Pump Cart Part No F6.244.09.0.00 , External Spline Hub For Fuel Pump Cart Part No F6.244.09.0.Pr , Bracket For Belt Tensioning Cart Part No F6.245.01.0.Pr , Cyl Head Sub Asslywith Valve Guide Valve Seat Insert Cart Part No F6.247.20.0.Pr , Cylinder Head Assembly Complete - (Sl90 4 Valves 300 Kva Crdi) Cart Part No F6.247.30.0.Pr , Inlet Connector Cart Part No F6.248.02.0.Pr , Crdi Injector For Sl90750htf142 Sca Cart Part No F6.248.08.0.Pr , Injector For 6Sl90ta 250 Kva Cpcb4 7 X 142 X 625K 1 3He 10 5 Cart Part No F6.248.13.0.Pr , Joint For Rocker Cover Cart Part No F6.249.03.0.Pr , Fuel Pipefor Fip To Filter Cart Part No F6.252.03.0.Pr , Fuel Pipefor Filter To Fip Cart Part No F6.252.04.0.Pr , Leak Off Pipe For Injectorpart 1 Cart Part No F6.252.11.0.Pr , Leak Off Pipe For Injectorpart 2 Cart Part No F6.252.12.0.Pr , Leak Off Pipefor Rail Pump Cart Part No F6.252.13.0.Pr , Leak Off Pipefor Fip Cart Part No F6.252.14.0.Pr , Radiator Fan: 28 Metalic Cart Part No F6.255.01.0.00 , Hose Connection Cart Part No F6.255.03.0.00 , Pipe: Thermostat To Water Tank Cart Part No F6.255.05.0.00 , Hose For Thermostat To Water Tank Cart Part No F6.255.06.0.00 , Hose: Water Connection Cart Part No F6.255.09.0.00 , Air Inlet Manifold Bend Cart Part No F6.255.12.0.00 , Joint: Bend Cart Part No F6.255.13.0.00 , Hose: Vent Connection Cart Part No F6.255.18.0.00 , Hose For Thermostat To Water Tank Cart Part No F6.255.32.0.00 , Hose: 160Kva Cart Part No F6.255.46.0.00 , Thermostat Cover Cart Part No F6.256.03.0.00 , Adaptor ( For 28 Fan ) Cart Part No F6.257.01.0.00 , Fip: 9 Mm Lift Cart Part No F6.259.10.0.00 , Extension Pipe For Catalyst Outlet Cart Part No F6.262.18.0.Pr , Fan Drive Pulley Assly S F C I Gear Casing Cart Part No F6.273.20.0.00 , Rubber Block Set(For Htb1200 Coupling) Cart Part No F6.290.20.0.00 , Cam Shaft & Gear Assembly Cart Part No F6.293.20.0.00 , Gasket (Between Turbochager & Exhaust Manifold) Cart Part No F6.294.12.0.00 , Fuel Injection Pump For 160Kva Cart Part No F6.296.10.0.00 , Radiator Cart Part No F6.297.01.0.00 , Assly Leak Off Pipe Cart Part No F6.304.01.0.00 , Gas Outlet Bend Cart Part No F6.315.01.0.00 , Expansion Bellow Cart Part No F6.315.03.0.00 , Air Delivery Bend Cart Part No F6.316.01.0.00 , Breather Pipe Support Clamp Cart Part No F6.320.09.0.00 , Leak Off Pipe: 250Kva Cart Part No F6.322.01.0.00 , Wet Pm Kit (W/O Oil) For F6.3422,F6.3423,F6.3445,F6.3622,F6.3623,F6.3624,F6.3645,F6.9623 - 6 Cart Part No F6.342.2.0.Sp , Turbocharger Cart Part No F6.350.01.0.00 , Crankshaft Assebly With Gear Cart Part No F6.351.40.0.Pr , Crankshaft Assebly With Gear Cart Part No F6.351.60.0.Pr , Flexible Connection: Ccase-Pump Cart Part No F6.353.05.0.00 , Clamping Nut For Motorpal Pump Cart Part No F6.353.09.0.00 , Fuel Pipe: Filter To Fip Cart Part No F6.353.11.0.00 , Fuel Pipe Primary To Secondary Cart Part No F6.353.112.0.00 , Fuel Pipepump To Filter Cart Part No F6.353.14.0.00 , Exhaust Manifold Cart Part No F6.357.01.0.00 , Exhaust Manifold Cart Part No F6.357.02.0.00 , Compression Ring Cart Part No F6.357.03.0.00 , Lube Oil Cooler-Plate Type Cart Part No F6.358.01.0.00 , Lub Oil Cooler Cartridge 16 Plate Cart Part No F6.358.15.0.00 , Valve Seat Insert Inlet Cart Part No F6.359.02.0.00 , Valve Seat Insert Exhaust Cart Part No F6.359.04.0.00 , Exhaust Valve Seat Insertsemifinishgas Engine Cart Part No F6.359.08.9.Pr , Cyl Head Assly Cart Part No F6.359.10.0.00 , Inlet Exhaust Valve Pair Cart Part No F6.359.12.0.Sp , Valve Pair Inlet & Exhaust Cart Part No F6.359.50.0.00 , Injector Cart Part No F6.361.02.0.00 , Copper Washernozzle Cart Part No F6.361.03.0.00 , Cooler Mounting Body Cart Part No F6.362.01.0.00 , Cooler Mounting Body (For 16 Plate Cooler) (Finish) Cart Part No F6.362.06.0.Pr , Oil Transfer Adaptor (Finish) Cart Part No F6.363.06.0.Pr , Sleeve (B/W Adaptor & Header ) Cart Part No F6.363.07.0.Pr , Oring Id 29 Od 3 Cart Part No F6.363.08.0.Pr , Lub Oil Pipe Assembly Cart Part No F6.363.10.0.Pr , Ss Joint: Turbocharger Outlet Cart Part No F6.364.02.0.00 , Stud: M10x1.5X65 Copper Coated Cart Part No F6.366.02.0.00 , Cyl Head Assly Cart Part No F6.366.10.0.00 , Nozzle For Sl90ta Cart Part No F6.368.14.0.00 , Pipe From Pump To Solenoid Cart Part No F6.371.02.0.00 , Pipe From Solenoid To Flame Heater Cart Part No F6.371.03.0.00 , V Belt: 106 Spb 1340 Cart Part No F6.375.11.0.00 , Hose Connection Cart Part No F6.375.15.0.00 , Fan: Plastic 30 Cart Part No F6.375.25.0.00 , Belt Tensioning Assly: 250Kva Cart Part No F6.375.30.0.00 , Pulley Pcd 90 Cart Part No F6.375.31.0.00 , Sub Asslycooler Cart Part No F6.376.10.0.00 , Turbocharger Cart Part No F6.377.035.0.00 , V Bend Clamp Cart Part No F6.377.04.0.00 , O Ring: Turbo Outlet Cart Part No F6.377.06.0.00 , Hose Cart Part No F6.377.08.0.00 , Joint: Turbo Inlet Cart Part No F6.377.09.0.00 , Support Bracket Assembly (For Air Pipe) (For Cpcb Ii) Cart Part No F6.377.100.0.00 , Stud: M8 Copper Coated Cart Part No F6.377.11.0.00 , Stud M10x1.5X025 (Copper Coated) Cart Part No F6.377.12.0.00 , Air Delivery Main Pipe From Tc To Cac Cart Part No F6.377.13.0.00 , Air Delivery Bend Cart Part No F6.377.14.0.00 , Joint: Air Delivery Mainpipe & Bend Cart Part No F6.377.15.0.00 , T Bolt Clamp S/F 83Mm Od Cart Part No F6.377.16.0.00 , Clamping Bracket Cart Part No F6.377.28.0.00 , Hose For Inlet Manifold Bend & Cac Out Cart Part No F6.377.33.0.00 , Cac Hose Cold Side Cart Part No F6.377.39.0.00 , Turbocharger For Sl90 Cpcb 4Engine076j89ss22n01en 080X73xl18c89esc15 Cart Part No F6.377.45.0.Pr , Crank Pulley Cart Part No F6.378.03.0.00 , Adaptor Plate Cart Part No F6.378.04.0.00 , Damper Pulley Cart Part No F6.378.11.0.00 , Damper Pulley Cart Part No F6.378.21.0.00 , Crank Pulley Pcd 210 Cart Part No F6.378.41.0.00 , Charge Air Manifold Cart Part No F6.379.01.0.00 , Inlet Manifold Bend Cart Part No F6.379.03.0.00 , Worm Drive Hose Clip (115 Mm) Cart Part No F6.379.07.0.00 , Joint: Inlet Manifold Bend Cart Part No F6.379.11.0.00 , Inlet Manifold Bend Cart Part No F6.379.14.0.00 , Joint Heater To Cac Pipe Cart Part No F6.379.17.0.Pr , Wet Pm Kit (W/O Oil) For F6.3805,F6.3806 Cart Part No F6.380.5.0.Sp , Gas Outlet Bend Cart Part No F6.381.01.0.00 , Bracket For Exhaust Outlet Cart Part No F6.381.02.0.00 , Expansion Bellow Cart Part No F6.381.03.0.00 , Joint: Bellow & Gas Outlet Cart Part No F6.381.04.0.00 , Set Screw M8x1.25X025 (Copper Coated) Cart Part No F6.381.05.0.00 , Gasket (Between Turbocharger & Diffuser) Cart Part No F6.381.15.0.Pr , Cyl Liner Assembly Cart Part No F6.382.10.0.00 , Cylinder Liner Assly. Cart Part No F6.382.20.0.Pr , Air Filter Primary Cart Part No F6.3855.51.0.Pr , Air Filter Safety Cart Part No F6.3855.52.0.Pr , Adaptor On Cooler Mtgbody For Jacket Water Heater Conn Cart Part No F6.387.03.0.00 , Valve Guide Finish Cart Part No F6.4004.02.0.00 , Valve Seat Insert: Inlet Cart Part No F6.4004.03.9.00 , Valve Seat Insert: Exhaust Cart Part No F6.4004.04.9.00 , Valve Bridge Cart Part No F6.4004.08.0.00 , Valve Pair Cart Part No F6.4004.100.0.00 , Cylinder Head Bolt Cart Part No F6.4004.12.0.00 , Sealing Cap22 Dia Cart Part No F6.4004.14.0.00 , Cylinder Head Assembly Complete Sl90 4 Valves Cart Part No F6.4004.160.0.Pr , Cylinder Head Assembly Complete Sl90 4 Valves Cart Part No F6.4004.30.0.00 , Valve Guide & Snap Ring Assembly Cart Part No F6.4004.40.0.00 , Push Rod Assly Cart Part No F6.4004.50.0.00 , Rocker Support Assembly Cart Part No F6.4005.70.0.00 , Rocker Cover Cart Part No F6.4006.07.0.00 , Rocker Cover (Machining) (Withoil Filling Arrangement) ( 4 Valve) Cart Part No F6.4006.08.0.00 , Joint: Rocker Cover Cart Part No F6.4006.13.0.00 , O Ring Cart Part No F6.4007.03.0.00 , Inlet Manifold Cart Part No F6.4008.01.0.00 , Joint: Inlet Manifold Cart Part No F6.4008.02.0.00 , Blanking Plate For Inlet Manifold Cart Part No F6.4008.03.0.00 , Spacer For Exhaust Manifold Cart Part No F6.4009.06.0.00 , Gasket For Exhaust Manifoldbetcylhead Exhmanifold Cart Part No F6.4009.12.0.00 , Banjo Bolt For Leak Off Pipe Cart Part No F6.4012.05.0.00 , Fuel Pipe Pre-Filter To Feed Pump Cart Part No F6.4012.11.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No F6.4012.12.0.00 , Lube Oil Supply Pipe To Fuel Pump Cart Part No F6.4012.14.0.00 , Leak Off Pipe Cart Part No F6.4012.22.0.00 , Bracket For Fuel Pipe Cart Part No F6.4012.26.0.00 , Leak Off Pipe Cart Part No F6.4012.35.0.00 , Fuel Pipe (Fuel Filter To Fuel Pump) Cart Part No F6.4012.36.0.00 , Fuel Pipe From Fuel Tank To Fuel Pump Cart Part No F6.4012.91.0.Pr , High Pressure Pipe Assembly Cart Part No F6.4013.100.0.00 , Cam Shaft Sub Assembly Sl90 4 Valves Cart Part No F6.4014.120.0.Pr , Cam Shaft Sub Assembly Sl90 4 Valves Cart Part No F6.4014.40.0.00 , Piston Assembly Cart Part No F6.4015.30.0.00 , Joint Betgear Casing Front Plate Cart Part No F6.4018.02.0.Pr , Gear Casing (Cast Iron ) Cart Part No F6.403.01.0.00 , Hose: Air Cleaner Cart Part No F6.404.01.0.00 , Air Filter Primary Outer Element Cart Part No F6.404.101.0.Pr , Air Filter Safety Cart Part No F6.404.102.0.Pr , Air Cleaner Kit For Sl90 Cart Part No F6.404.15.0.00 , Bracket For Air Cleaner Cart Part No F6.404.17.0.00 , Air Cleaner Assly Cart Part No F6.404.25.0.00 , Air Filter Primary Cart Part No F6.404.27.0.00 , Air Filter Safety Cart Part No F6.404.28.0.00 , Restriction Indicator Cart Part No F6.404.31.0.00 , Hose Reducer Cart Part No F6.404.32.0.00 , Hose Reducer Cart Part No F6.404.36.0.00 , Fuel Return Pipe Cart Part No F6.404.56.0.Pr , Fuel Return Pipe Cart Part No F6.404.57.0.Pr , Hose Reducer Elbow Cart Part No F6.404.59.0.Pr , Hose For Air Cleaner Cart Part No F6.404.74.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-1) Cart Part No F6.406.32.0.Pr , Adblue Pipe For (Adblue Tank Out To Supply Module In-2) Cart Part No F6.406.33.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-1) Cart Part No F6.406.35.0.Pr , Adblue Pipe For (Supply Module Back Flow To Adblue Tank In-2) Cart Part No F6.406.36.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Cart Part No F6.406.38.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 2 Cart Part No F6.406.39.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Cart Part No F6.406.41.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 1 Cart Part No F6.406.43.0.Pr , Adblue Pipe For (Supply Module Out To Dosing Module In-2) Cart Part No F6.406.44.0.Pr , Adblue Pipe Forsupply Module Out To Dosing Module In 3 Cart Part No F6.406.46.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 1 Cart Part No F6.406.47.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 2 Cart Part No F6.406.48.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 3 Cart Part No F6.406.49.0.Pr , Coolant Pipe Forheader Out To Dosing Model In 4 Cart Part No F6.406.51.0.Pr , Fuel Inlet Pipe From Filter To Pump Cart Part No F6.406.62.0.Pr , Hose Between Pump Inlet And Radiator Pipe Outlet Cart Part No F6.406.64.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 1 Cart Part No F6.406.67.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 2 Cart Part No F6.406.68.0.Pr , Coolant Pipe Fordosing Module Out To Radiator In 3 Cart Part No F6.406.69.0.Pr , Fuel Supply And Return Block Cart Part No F6.418.01.0.00 , Fuel Leak Off Pipe Assly(Fire Fighting) Cart Part No F6.418.02.0.00 , Fuel Supply Pipefrom Supply Block To Fuel Pump Cart Part No F6.418.03.0.00 , Adaptor For Fuel Supply And Return Block Cart Part No F6.418.04.0.00 , Fuel Leak Off Pipe Assly Fire Fighting Cart Part No F6.418.05.0.00 , Leak Off Pipe Assembly Cart Part No F6.418.08.0.00 , Cover Plate Cart Part No F6.420.22.0.00 , Barring Assly Cart Part No F6.420.25.0.00 , Set Screw M14x35 For Barring Arrg Cart Part No F6.420.29.0.Pr , Cooler Cover Cart Part No F6.420.52.0.00 , Water Pump Pulley Cart Part No F6.424.01.0.00 , Water Pump Pulley Cart Part No F6.424.21.0.00 , Current Transformer (Set Of 4Ct) 500/5A For Frame-284 Cart Part No F6.443.04.0.00 , Current Transformer(Set Of 4Ct) 1000/5A Frame -354 Cart Part No F6.443.05.0.00 , 200Kva Alternator Sae 2 /11.5 Cart Part No F6.443.16.0.Pr , Engine Control Digital Display 24Vdc Cart Part No F6.465.33.0.00 , Instrumentation Control Panrl Assembly Cart Part No F6.465.50.0.00 , Starter Solenoid(Dumore, 535-0098)24V For F.Fighting Cart Part No F6.474.02.0.00 , Water Heater(Kim Hotstart, Tps202gt12-006, 2.0Kw, 240V) Cart Part No F6.482.01.0.00 , Actuator(Xadc225d1s - 24) For Fire Fighting Appln. Cart Part No F6.483.01.0.00 , Spacer For Link(M6 X1 Lh - M6x1 Rh) Cart Part No F6.483.04.0.00 , Link(M6x1 Lh - M6x1 Rh) Cart Part No F6.483.06.0.00 , Adaptor (M6x1-M6x1) Cart Part No F6.483.12.0.00 , 70 Pin Engine Control Modulesecm70 Cart Part No F6.488.01.0.Pr , Delta Pressure Sensor Sensor In The Efr Cart Part No F6.488.02.0.Pr , Sensor Cart Part No F6.488.03.0.Pr , Electronic Flow Regulator Efr Cart Part No F6.488.04.0.Pr , F Series Throttle Body Cart Part No F6.488.05.0.Pr , Ignition Coil Cart Part No F6.488.06.0.Pr , Exhaust Silencer: 4 Id Cart Part No F6.503.01.0.00 , Joint Ss: 4 Cart Part No F6.503.02.0.00 , Flange-Id 4 Cart Part No F6.503.04.0.00 , Air Cleaner: 14+Mtg Strap Cap Cart Part No F6.504.01.0.00 , Range Restriction Indicator 1/8 24 Cart Part No F6.504.02.0.00 , Air Cleaner Element-14 Cart Part No F6.504.08.0.00 , Air Cleaner Assly: Dry 11.5 Cart Part No F6.504.32.0.00 , Filter Element For 11.5Jjf Drytype Air Cleaner Cart Part No F6.504.34.0.00 , Hood For 11.5 Filter Cart Part No F6.504.35.0.00 , Adaptor: M24x1.5M-M10x1.5F Cart Part No F6.505.12.0.00 , Engine Mtg Foot Cart Part No F6.508.01.0.00 , Hard Washer(12 Id) Cart Part No F6.508.03.0.00 , 500 Hrs - B Check Maintenance Kit Cart Part No F6.508.18.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No F6.508.19.0.Sp , 50 Hrs - A Check Maintenance Kit Cart Part No F6.508.22.0.Sp , Water Suction Connection Cart Part No F6.509.03.0.00 , Anti Vibration Mounts Cart Part No F6.509.04.0.00 , Hose: Radiator Inlet 50 Id Cart Part No F6.509.05.0.00 , Hose: Radiator Outlet 60 Id Cart Part No F6.509.06.0.00 , Adaptor(M14*15 To M14*2) Cart Part No F6.509.13.0.00 , Flexible Pipe: M14xm14x600 L Cart Part No F6.509.14.0.00 , Rubber Block(0.37 Holset Coupling) Cart Part No F6.510.02.0.00 , Holset Coupling 0.37 Rb 45 Mm Pilot Bore Cart Part No F6.510.10.0.00 , Ssjoint(For Turbo Outlet) Cart Part No F6.516.02.0.00 , Bracket Gas Outlet Manifold Cart Part No F6.516.05.0.00 , Charging Alternator 28V 45A Cart Part No F6.531.01.0.00 , Pulley Cart Part No F6.534.01.0.00 , Pulley 124 Pcd A Sect Cart Part No F6.534.02.0.00 , Fan Drive Assembly (S/F C.I Gear Casing) Cart Part No F6.534.20.0.00 , Starter Ring Cart Part No F6.537.02.0.00 , Flywheel Assembly Cart Part No F6.537.10.0.00 , Flywheel Assly With Starter Ring (Heavy) Cart Part No F6.537.50.0.Pr , Crank Pulley (3 Grooves,210 Pcd) Cart Part No F6.544.01.0.00 , Heat Exchanger Cart Part No F6.549.01.0.00 , Fresh Water Inlet Conn.On Heat Exchanger Cart Part No F6.549.03.0.00 , Hose: Thermostat Hsg To Int. Pipe Cart Part No F6.549.06.0.00 , Intermediate Pipe(For He In Conn)Al Cast Cart Part No F6.549.13.3.00 , Expansion Bellow: 4 With 4Mtg Hole Cart Part No F6.550.01.0.00 , Non Return Valve 1 Bsp Cart Part No F6.554.04.0.00 , Flexible Pipe (M30 X M30 U 600 L) Cart Part No F6.554.08.0.00 , Mounting Bracket For Make Up Water Tank Cart Part No F6.557.01.0.00 , Mounting Plate For Make Up Water Tank. Cart Part No F6.557.03.0.00 , Make Up Water Tank. Cart Part No F6.557.04.0.00 , Clamping Strap For Makeup Water Tank Mtg Cart Part No F6.557.05.0.00 , Special Stud Cart Part No F6.557.06.0.00 , Cover With Press Cap Cart Part No F6.557.07.0.00 , Outlet Pipe Conn On Makeup Water Tank Cart Part No F6.557.08.0.00 , Flexible Pipe Vent For W.Tank Cart Part No F6.557.09.0.00 , Compression Ring Cart Part No F6.560.01.0.00 , Stop Solenoid: 24V Energ-Run Cart Part No F6.561.04.0.00 , Exhaust Bend (S/F Schwing) Cart Part No F6.562.02.0.00 , Adaptor For Prswitch Cart Part No F6.564.01.0.00 , Holset Coupling O.37 Rb 35 Mm Pilot Bore Cart Part No F6.565.10.9.00 , Set Of O Rings: 6Sl9088t Cart Part No F6.566.10.0.00 , Set Of Joints 6Sl9088t Engine. Cart Part No F6.566.20.0.Sp , Set Of Copper Washer Cart Part No F6.566.30.0.00 , Set Of Joints For 6Sl9088ta Engine/F6.3021/F6.3221/F6.3421/F6.3621/F6.3821(Standrad)/F Cart Part No F6.566.40.0.Sp , Set Of O Rings Cart Part No F6.566.50.0.00 , Set Of Copper Washer Cart Part No F6.566.60.0.00 , Set Of Joints Cart Part No F6.566.70.0.Sp , Set Of O Rings Cart Part No F6.566.80.0.00 , Sub Assly Of Hose Tail M 12 Banjo Cart Part No F6.569.10.0.00 , Stop Solenoid: 24V Energ-Run Cart Part No F6.570.06.0.00 , Water Pump Pulley Cart Part No F6.579.01.0.00 , Water Pump Pulley Pcd 190 Cart Part No F6.579.21.0.00 , Hose For Air Cleaner Cart Part No F6.594.06.0.00 , Bush Cart Part No F6.606.03.0.00 , Washer For Axual Alignment Cart Part No F6.606.04.0.00 , Spacer Cart Part No F6.606.05.0.00 , Pulley For Alternator Cart Part No F6.606.06.0.00 , Lever Cart Part No F6.606.07.0.00 , Bracket: Alternator Cart Part No F6.606.08.0.00 , Pulley For Alternator( 2 Groove, 81 P.C.D.) Cart Part No F6.606.09.0.00 , Alternator Pulley Cart Part No F6.606.21.0.00 , Pressure Sender For Pricol Single Wire Connection Cart Part No F6.610.02.0.00 , Speed Control Cart Part No F6.614.02.0.00 , Expansion Bellow: 4 Cart Part No F6.618.01.0.00 , Joint Ss Cart Part No F6.618.02.0.00 , Engine Mtg Foot Cart Part No F6.628.01.0.00 , Engine Mounting Foot For Transportation Cart Part No F6.628.05.0.00 , Bracket For Altrnator Cart Part No F6.639.01.0.00 , Alternator: 24V 45A Wo Blocking Diode Cart Part No F6.639.04.0.00 , Bracket For 11.5Air Cleaner Cart Part No F6.640.01.0.00 , Air Cleaner Element 11.5 Cart Part No F6.640.02.0.00 , 0.73Rb Coupling Cart Part No F6.657.20.0.00 , Radiator Assly For Ural Cart Part No F6.669.01.0.00 , Fan For Ural Cart Part No F6.669.02.0.00 , Flex.Hose For Vent Cart Part No F6.669.09.0.00 , Lube Oil Drain Pipe Assly Cart Part No F6.670.34.0.00 , Hose For Air Suction Pipe Cart Part No F6.670.98.0.Pr , Joint: Air Inlet Manifold Cart Part No F6.674.04.0.00 , Radiator Al Cac 200Kva Cart Part No F6.680.01.0.00 , Pipe For Thermostat To Water Tank Of Radiator Cart Part No F6.680.04.0.00 , Rubber Hose: Main Pipe 100X100x180l Cart Part No F6.680.06.0.00 , Suction Connection Cart Part No F6.680.08.0.00 , Lug For Stay Cart Part No F6.680.11.0.00 , Stay For Radiator Cart Part No F6.680.12.0.00 , Holding Bracket Cart Part No F6.680.13.0.00 , Clamping Bracket140 To 160Kva Cart Part No F6.680.23.0.00 , T Bolt Clamp Cart Part No F6.680.25.0.00 , Circlip: Seegev Cart Part No F6.701.03.0.00 , Big End Bearing Top (Str) 250Kva Cart Part No F6.701.05.0.00 , Big End Bearing Bottom (Str) 250Kva Cart Part No F6.701.06.0.00 , Con Rod Assly: 250 Kva W/0 Brg Cart Part No F6.701.10.0.00 , Connecting Rod Assembly Cart Part No F6.701.100.0.Pr , Connecting Rod Assembly With Big End Bearing Cart Part No F6.701.110.0.Pr , Big End Bearing Top Cart Part No F6.701.16.0.Pr , Big End Bearing Bottom Cart Part No F6.701.17.0.Pr , Piston Assembly Cart Part No F6.701.20.0.00 , Connecting Rod Assly Cart Part No F6.701.40.0.00 , Piston Assembly Cart Part No F6.701.61.0.00 , Fuel Pipe Inlet Water Seprater To Fip Cart Part No F6.708.08.0.00 , Fuel Pipe Return: M12x1.5 Male Plug X M14 X 1.5 Banjo 700Mm Cart Part No F6.708.12.0.00 , Fip: 250Kva Cart Part No F6.713.01.0.00 , Adaptor Cart Part No F6.713.02.0.00 , Bracket For Fip Mounting Cart Part No F6.713.04.0.00 , Joint: Flange Cart Part No F6.713.05.0.00 , O Ring 15 I.D X1.78 Dia Section Cart Part No F6.713.08.0.00 , Adaptor For Fuel Pipem14x1 5 X 14X1 5 Cart Part No F6.713.09.0.00 , Fip For Sl90 Main Propulsion 1800 Rpm Cart Part No F6.713.105.0.Pr , Feed Pump Cart Part No F6.713.26.0.00 , Air Cleaner 16 Cart Part No F6.729.01.0.00 , Bracket For Air Cleaner Cart Part No F6.729.02.0.00 , 16Air Cleaner Primary Elemt Cart Part No F6.729.03.0.00 , Safety Air Filter Elemnt Cart Part No F6.729.04.0.00 , 16 Air Cleaner Hood With Clamp Assembly Cart Part No F6.729.05.0.00 , Primary Air Cleaner Element Cart Part No F6.729.07.0.00 , Air Cleaner Safety Element Cart Part No F6.729.08.0.00 , Hose: Air Inlet 250 Kva Cart Part No F6.729.13.0.00 , Hose: Air Cleaner Cart Part No F6.729.19.0.00 , Pipe Complete Assly With Clamps Cart Part No F6.734.10.0.00 , Bracket For Adc 225 Gs Governor Cart Part No F6.741.01.0.00 , Link: Adc C225 Gs Cart Part No F6.741.02.0.00 , Wiring Harness Cart Part No F6.741.03.0.00 , Control Unit Cart Part No F6.741.06.0.00 , Magnetic Pup Thread 16X1.5 Cart Part No F6.741.07.0.00 , Braket For Adc225 Gac Actuator Cart Part No F6.741.08.0.00 , Spacer For The Fitment Of The Governor Linkage For The Gav G Cart Part No F6.741.09.0.00 , Relay Mod 24V Dc Cart Part No F6.741.12.0.00 , Magnetic Pickup: Dual Two Connector Cart Part No F6.741.14.0.00 , Magnetic Pick Up 16X1 5 Threadingfor 250 Kva With 110 Series Mssl Con Cart Part No F6.741.16.0.00 , Magnetic Pick Up With Ampconnectorwith Econoseal J Type For Industrial Appl Cart Part No F6.741.19.0.00 , Dual O P Mpu Cart Part No F6.741.26.0.Pr , Magnetic Pick Up16x1.5 Thread Cart Part No F6.741.28.0.Pr , Dual O P Mpu Cart Part No F6.741.29.0.Pr , Magnetic Pickup: Amp Connector Cart Part No F6.741.31.0.Pr , Control Unit Esd 2210 S F Solo Cart Part No F6.742.06.0.00 , Lever For Elec Actuator Cart Part No F6.742.08.0.00 , Cac Pipe Turbo Bend Pipe To Extended Cac Cart Part No F6.744.07.0.00 , O Ringid 69 6 5 Mm Cart Part No F6.744.12.0.Pr , Cac Pipehot Side Cart Part No F6.744.14.0.Pr , Water Cooled Cac-For Fire Fighting (296Hp/1500) Cart Part No F6.746.01.0.00 , Heat Exchanger Fire Fighting Cart Part No F6.746.02.0.00 , Cac Outlet Pipe (Watercooled Cac) Cart Part No F6.746.04.0.00 , Joint: Watercooled Cac Cart Part No F6.746.05.0.00 , Hose: Suct Conn 60 Idx 70Odx 60Mm Cart Part No F6.746.14.0.00 , Rubber Hosefor Drain Pipe Cart Part No F6.748.04.0.Pr , Jointbetturbo Adaptor Crankcase Cart Part No F6.748.05.0.Pr , Jointbetween Turbo Drain Pipe Cart Part No F6.748.13.0.00 , Jointbetween Turbo Drain Pipe Cart Part No F6.748.13.0.Pr , Hose For Cac Pipe Cart Part No F6.749.11.0.Pr , Lub Oil Headerfor Sl90 320 Kva Finish Cart Part No F6.755.06.0.Pr , Plunger For Relief Valve Cart Part No F6.755.07.0.Pr , Springfor Relief Valve Cart Part No F6.755.08.0.Pr , Oringb W Header Crankcase Cart Part No F6.755.12.0.Pr , Hx40 Holset Turbo 332 2100 40 L8294 H18e Profile 8 Cart Part No F6.759.05.0.00 , Joint For Exhaust Silencer Cart Part No F6.768.02.0.00 , U Strip Clamp For 160 125Kva Cart Part No F6.768.04.0.00 , Silencer For 6Ksl90 Cpcb Iv Cart Part No F6.768.15.0.Pr , Rain Cap Cart Part No F6.768.50.0.00 , Damper Cart Part No F6.783.01.0.00 , Special Crank Pulley Cart Part No F6.784.01.0.00 , Special Driving Hub Cart Part No F6.785.01.0.00 , Expansion Bellow Cart Part No F6.786.01.0.00 , Fip For Sl90ta Cart Part No F6.795.03.0.00 , Fuel Injection Pump Assmebly Cart Part No F6.795.13.0.00 , Fuel Feed Pump9 440 0 30 003 Cart Part No F6.795.18.0.Pr , Cam Gear Speed Ring Cart Part No F6.800.07.0.Pr , Countersunk Socket Head Screw Cart Part No F6.800.08.0.Pr , Exhaust Diffuser Cart Part No F6.801.04.0.00 , Hose Forair Cleaner Cart Part No F6.801.09.0.00 , Radiator Cart Part No F6.801.10.0.00 , Hose (From Radiator To Water Pump) Cart Part No F6.801.11.0.00 , Pipe (Thermostat To Radiator) Cart Part No F6.801.13.0.00 , Fuel Return Pipe Cart Part No F6.801.15.0.00 , Fuel Pipe Pre-Filter To Tank Cart Part No F6.801.23.0.00 , T- Bolt Clamp(159Mm - 167Mm) Cart Part No F6.801.24.0.00 , Bracket For Actuator Mounting Cart Part No F6.801.25.0.00 , Vent Pipe Cart Part No F6.801.26.0.00 , Vent Pipe Cart Part No F6.801.27.0.00 , Fuel Return Pipe Cart Part No F6.801.28.0.00 , Fuel Level Sensor 145Mm Cart Part No F6.802.19.0.00 , Hard Washer( For M20 Bolt). Cart Part No F6.811.02.0.00 , Hard Washer (Id 17,Od 35,Thk 5) Cart Part No F6.811.04.0.00 , Avr Model Tavr-3A S/F Kg Alternator Cart Part No F6.814.11.0.00 , Rotating Rectifier Assly: 6 Diode Cart Part No F6.814.15.0.00 , Rotating Reefifer Assembly With 6Nos. Diode&Heatsink S/F Kg Alternator Cart Part No F6.814.16.0.00 , Excitor Rotor Assemblytex2.1 S/F Kg Alternator Cart Part No F6.814.17.0.00 , Terminal Block S/F Kg Alternator Cart Part No F6.814.25.0.00 , Nde Shield S F Kg Alternator 320Kvaframe Size Ta284c Cart Part No F6.814.48.0.00 , Avr Cart Part No F6.815.41.0.00 , Hose For Air Delivery Bend Cart Part No F6.840.05.0.00 , Hose At Cac In (100 Id X 100 Id X 80 Length) Cart Part No F6.840.16.0.00 , Relay Board: Single Chanel Cart Part No F6.857.01.0.00 , Control Panel Asslyf F Application S F Eletronic Governor With Idle And Run Sw Cart Part No F6.858.20.0.00 , Relay 24Vdc Cart Part No F6.860.11.0.00 , Dc Volt Meter 16 T0 32 V 52 Dia Cart Part No F6.863.06.0.00 , Relay Board 2.5 Ch 70 Amp Cart Part No F6.863.17.0.00 , Relay Board Cart Part No F6.865.05.0.00 , Selctor Switch2 Way With Center Off 2Pole Cart Part No F6.873.01.0.00 , Turbocharger Cart Part No F6.889.02.0.00 , Turbocharger Cart Part No F6.889.03.0.00 , Air Delivery Bend: 200Kva Cart Part No F6.889.04.0.00 , O Ring (For Turbo Outlet) Cart Part No F6.889.05.0.00 , Air Delivery Bend (Turbocharger) Cart Part No F6.889.08.0.00 , Cac Hose Hot Side 4 Plies Lakshaya Project Cart Part No F6.889.16.0.Pr , Solid State Lamp 183 Ma: 8-30V Cart Part No F6.900.23.0.00 , Low Engine Coolant Temperature Switch Cart Part No F6.906.70.0.00 , Raw Water High Temprature Switch Cart Part No F6.906.71.0.00 , Engine Coolant Temprature Switch. Cart Part No F6.906.72.0.00 , Magnetic Pickup M16x1.5 Cart Part No F6.908.01.0.00 , Low Lub Oil Pressure Switch Setting2 Bar 1/8 Npt With Two Screw Terminals Cart Part No F6.908.11.0.00 , Water Temp Switch 98 Deg C Cart Part No F6.909.69.0.00 , Wiring Harness For Fire Fighting(250Kva) Cart Part No F6.917.20.0.00 , Piston Assly For 160 Kva Gas Engine Cart Part No F6.920.10.0.00 , Wiring Harness Assembly Sl90 Fm_Ul New Cart Part No F6.928.11.0.00 , Wiring Harness: Fire Fighting Cart Part No F6.928.20.0.00 , Wiring Harness Assembly Sl-90 Engine F.F.Set (Spp Fmul Project) With Alternator Cart Part No F6.928.30.0.00 , Wiring Harness Assembly From Engine Control Panel To Main Fire Fighting Panel Cart Part No F6.928.60.0.00 , Earthing Cable (Pvc ,Green Colour) For Radiator To Starter2.5 Sq.Mm. Cart Part No F6.933.24.0.00 , Radiator With Cacverticals F 200 Kva Cart Part No F6.941.10.0.Sp , Engine Control Unit Cart Part No F6.942.01.0.00 , Actuator 24Vdc Sl90 Cart Part No F6.942.02.0.00 , Ecu E-Governer B12 24Vdc Sl90 Cart Part No F6.942.03.0.00 , Actuator: 24Vdc Sl90 Cart Part No F6.942.12.0.00 , Oil Seal Pressing Toolfwe Cart Part No F6.950.04.0.00 , Oil Seal Pressing Mandrelge Cart Part No F6.950.05.0.00 , Piston Ring Set (Pvd 4 Valve) Cart Part No F6.953.20.0.Pr , Ht Cable Set(6 Ht Cables) For Biogas Kit For Sl90 Engine Cart Part No F6.956.10.0.00 , Turbocharger Holset Hx50s F Fire Fighting Cart Part No F6.957.01.0.00 , Engine Wiring Assly: Ems907 Cart Part No F6.959.10.0.00 , Exhaust Manifold (Central Piece) Cart Part No F6.969.01.0.00 , Air Delivery Bend (For Holset Hx50 Tubocharger) Cart Part No F6.969.02.0.00 , Joint Between Air Bend & Cac-In Pipe Cart Part No F6.969.03.0.00 , Air Delivery Main Pipe Cart Part No F6.969.04.0.00 , Adaptor For Oil Inlet To Turbo Cart Part No F6.969.07.0.00 , Joint At Turbine Outlet Of Hx-50 Turbocharger Cart Part No F6.969.08.0.00 , Lube Oil Drain Pipe Assembly Cart Part No F6.969.09.0.00 , Hose: Comp Out To Air Delivery Bend Cart Part No F6.969.11.0.00 , Lub Oil Supply Pipe To Turbo Charger Cart Part No F6.969.20.0.00 , Hose: Comp. Out To Air Delivery Pipe Cart Part No F6.969.24.0.00 , Control Panel Assembly Suitable For Engine Saftey Unit Ems 907 Cart Part No F6.971.10.0.00 , Wiring Harness Assembly For 140 Kva To 200 Kva Cart Part No F6.973.10.0.00 , Hose: Air Cleaner Cart Part No F6.980.01.0.00 , Hose (From H.Exchanger Pipe To Suction ) Cart Part No F6.982.05.0.00 , Hose (From Thermostat To H.E) Cart Part No F6.982.06.0.00 , Adaptor With Flange For H. Exchanger Cart Part No F6.982.08.0.00 , Joint: Heat Exchanger Cart Part No F6.982.11.0.00 , Hose: Cac Pipe And H.E. Cart Part No F6.982.12.0.00 , Adaptor On Heat Exchanger Cart Part No F6.982.13.0.00 , Adaptor For Vent Pipe(M14x15 To 1/4) Cart Part No F6.982.14.0.00 , Heat Exchanger(S/F Fresh Water) For 6Rta And Sl90ta F.F. Engines Cart Part No F6.982.17.0.00 , Water Delivery Pipe Cart Part No F6.982.19.0.00 , Air Cleaner F.F. Engines Cart Part No F6.983.01.0.00 , Hose: Air Cleaner Cart Part No F6.983.03.0.00 , Air Cleaner Assembly Cart Part No F6.983.07.0.00 , Water Heater(Kim Hotstart, Tps 152Gt12-006, 1.5Kw, 240V) Cart Part No F6.984.01.0.00 , Bracket For Water Heater Mounting Cart Part No F6.984.05.0.00 , Terminal Block Cart Part No F6.984.10.0.00 , Hose Clamp Cart Part No F6.986.02.0.00 , Hood Assembly Cart Part No F6.986.06.0.00 , Hose Clamp Cart Part No F6.986.08.0.00 , Vacuum Indicator(25) Cart Part No F6.986.09.0.00 , Air Cleaner Primary Element Cart Part No F6.986.11.0.00 , Air Cleaner Safety Element Cart Part No F6.986.12.0.00 , Dust Cap Cart Part No F6.986.19.0.00 , Adaptor(0.25 Bsp To M16 X 1.5 ) Cart Part No F6.986.21.0.00 , Air Cleaner Assembly Kit Cart Part No F6.986.30.0.00 , Mounting Bracket Cart Part No F6.992.08.0.00 , Mounting Bracket Assembly Cart Part No F6.992.09.0.00 , Water Cooled Cac For F.F. Cart Part No F6.993.01.0.00 , Pipe(From Cac To H.E.) Cart Part No F6.993.08.0.00 , Joint: Raw Water Inlet/Outlet Cart Part No F6.993.13.0.00 , Centrifugal Filter Service Kit Cart Part No F6.999.100.0.00 , Control Panel Door Hinge 40Mm Cart Part No F6.999.109.0.Sp , Fuel Return Line Nrv Kit Cart Part No F6.999.110.0.00 , Control Panel Door Hinge 50Mm Cart Part No F6.999.111.0.Sp , Fuel Return Line Nrv Kit Cart Part No F6.999.130.0.00 , Wet Pm Kit (W/O Oil) For F6.8621..F6.9729...F6.8737.. - 6Sl1500ta Cart Part No F6.999.31.0.Sp , Wet Pm Kit (W/O Oil) For F6.3810 - 6Sl8800 Ta Cart Part No F6.999.40.0.Sp , Wet Pm Kit (W/O Oil) For F6.8625...F6.9630...F6.8733..- 6Sl1500ta Cart Part No F6.999.44.0.Sp , Wet Pm Kit (W/O Oil) For F6.8618 - 6Sl1500ta G2 Cart Part No F6.999.47.0.Sp , Wet Pm Kit (W/O Oil) For F6.2502, F6.2562, F6.2703.20, F6.3614, F6.3622, F6.3405, F6.3605, F6.3 Cart Part No F6.999.53.0.Sp , Wet Pm Kit (W/O Oil) For F6.8734 Cart Part No F6.999.72.0.Sp , Pressure Regulator First Level For 125Kvar 5201 Cart Part No F6.999.73.0.Sp , Wet Pm Kit (W/O Oil ) For F6.9860 Cart Part No F6.999.74.0.Sp , Wet Pm Kit (W/O Oil ) For F6.8802, F6.8841 Cart Part No F6.999.75.0.Sp , Wet Pm Kit (W/O Oil) For F6.3005, F6.3008, F6.3208 - 6Sl9088ta Cart Part No F6.999.78.0.Sp , Wet Pm Kit (W/O Oil) For F6.9620..., F6.8736..., F6.9822... - 6Sl8800ta Cart Part No F6.999.94.0.Sp , Wet Pm Kit (W/O Oil) For F6.2041, F6.3205, F6.2007, F6.2243, F6.2279, - 6Sl9088ta Cart Part No F6.999.95.0.Sp , Doc Catalyst (12 Dia X 5 Length, 15 G/Cft, 5/1 Pt:Pd, Fresh) Cart Part No F6.Egt4.10.0.Pr , Doc Catalyst12dia X 5Length20 G Cft5 1 Pt Pdfresh Cart Part No F6.Egt4.12.0.Pr , Scr Catalyst First Brick - Fresh (12 Dia X 7 Length, Wcl 2.75 G/In3) Cart Part No F6.Egt4.15.0.Pr , Scr Catalyst Second Brick - Fresh (12 Dia X 7 Length, 2.1 G/In3 On 5? Length, Asc 2 Cart Part No F6.Egt4.16.0.Pr , 12 V Band Clamp Machined Flange_82585245 Cart Part No F6.Egt4.22.0.Pr , 12Gasket 82602769 Cart Part No F6.Egt4.23.0.Pr , Dosing Module B444 606 555Dm2 2 6 Hole9 Bar Cart Part No F6.Egt4.24.0.Pr , Supply Module B444 606 941 (Sm 2.2 Evo Bl, 24 V, 9 Bar) Cart Part No F6.Egt4.25.0.Pr , Adblue Levelquality Temp Sensor For 45 Ltr Tank Cart Part No F6.Egt4.26.0.Pr , Exhaust Temp Sensor For Cpcb4 Cart Part No F6.Egt4.28.0.Pr , F6.Egt4.31.0.00 12 Egt System Assembly (Cpcb 4+ ) Cart Part No F6.Egt4.31.0.Sp , F6 Egt4 32 0 0012Egt System Assemblydoc20 G Cftscr2 75 G In3 Cart Part No F6.Egt4.32.0.Sp , Pipe For Turbo Oil Supply Cart Part No F6.M019.12.0.00 , Oringid 29 91 Dia 5 Mm Cart Part No F6.P008.05.0.Pr , Oringid 30 45 Dia 3 Mm Cart Part No F6.P008.07.0.Pr , 6Pk Poly-V Section Belt Cart Part No F6.P012.01.0.Pr , Fip Adaptor & Bush Assembly Cart Part No F6.P014.10.0.Pr , Fuel Filter Element 0 25 Lit Cart Part No Fa1.031.02.0.00 , Fuel Filter Assembly Cart Part No Fa1.031.20.0.00 , Bearing Bush Nt Kir Ra3 Cart Part No G.038.5.01.703 , Bearing Ig Bush: Ha394 Cart Part No G.073.5.00.703 , Main Bearing Ig Bush R1040/4K1080 Cart Part No G.584.5.00.703 , Crankcase Assembly With M B Cap Cart Part No Gp2.001.10.0.Pr , Camshaft Assembly Cart Part No Gp2.003.10.0.Pr , Cylinder Head Gasket Cart Part No Gp2.005.13.0.Pr , Rocker Lever Assembly Cart Part No Gp2.007.50.0.Pr , O Ringfor Fip Side Cover Plate Cart Part No Gp2.011.21.0.Pr , Gasket For Inlet Manifold Cart Part No Gp2.014.02.0.Pr , High Pressure Pipe Assembly Cart Part No Gp2.015.40.0.Pr , Adaptor For Housingsae4 Cart Part No Gp2.021.03.0.Pr , Adaptor For Flywheelsae 7 5 Cart Part No Gp2.021.04.0.Pr , Flywheel & Starter Ring Assembly Cart Part No Gp2.021.10.0.Pr , Gasket For Rocker Cover Cart Part No Gp2.035.08.0.Pr , Fan For R550 Cart Part No Gp2.039.06.0.Pr , Fuel Pipefuel Filter To F I P Cart Part No Gp2.047.02.0.Pr , 50 Hrs - A Check Maintenance Kit Cart Part No Gp2.047.06.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Gp2.047.08.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Gp2.047.09.0.Sp , Leak Off Pipepoly Amide Cart Part No Gp2.048.01.0.Pr , Lop Sensor,5V, Ratiometeric,Honeywell Cart Part No Gp2.100.01.0.Pr , Temperature Sensor,Ntc Type_Honeywell_Probe Length 10Mm Cart Part No Gp2.100.07.0.Pr , Hose From Thermostat To Radiator Cart Part No Gp2.107.06.0.Pr , Suction Hose Cart Part No Gp2.107.12.0.Pr , Clamp For Hose Cart Part No Gp2.107.13.0.Pr , Rubber Sleeve For Hose Cart Part No Gp2.107.14.0.Pr , Radiator Assembly For 2R550 Cart Part No Gp2.107.25.0.Pr , Fuel Tank Unit For 2R550exports Cart Part No Gp2.108.08.0.Pr , Fuel Hose From Fuel Tank To Pump Cart Part No Gp2.108.26.0.Pr , Fuel Pipefrom Pump To Feedpump Cart Part No Gp2.108.27.0.Pr , Anti Vibration Mount Cart Part No Gp2.110.07.0.Pr , Engine Wiring Harness For 2R550 10 12Kva Engine With Ag48 And Kg645c Cart Part No Gp2.225.50.0.Pr , Hex. Head Screw (For M.B. Cap) Cart Part No Gp3.001.05.0.Pr , Cam Shaft Bushna Tc Cart Part No Gp3.001.06.0.Pr , Crankcase Assemblywith M Bcap Cart Part No Gp3.001.10.0.Pr , Hollow Dowel Dia 11 (Gear End) Cart Part No Gp3.001.11.0.Pr , Socket Head Grub Screw M16x2 Cart Part No Gp3.001.13.0.Pr , Oil Spray Nozzle Cart Part No Gp3.001.14.0.Pr , Hollow Dowel Dia 12 (For Cylinder Head) Cart Part No Gp3.001.15.0.Pr , Threaded Adaptor(For Oil Filter) Cart Part No Gp3.001.19.0.Pr , Pin (For Banjo) Cart Part No Gp3.001.26.0.00 , Plugfor Banjo Cart Part No Gp3.001.27.0.Pr , Banjo Boltfor Oil Supply Cart Part No Gp3.001.28.0.Pr , Banjo Bolt For Header Cart Part No Gp3.001.29.0.Pr , Banjo Boltfor Turbo Oil Supply Pipe Cart Part No Gp3.001.33.0.Pr , Carnkcase Assemblywith M Bcap Cart Part No Gp3.001.50.0.Pr , Crank Gear Cart Part No Gp3.002.02.0.Pr , Crankshaft Assemblywith Crank Gear Cart Part No Gp3.002.10.0.Pr , Cam Gear Cart Part No Gp3.003.02.0.Pr , Thrust Plate (Cam Shaft) Cart Part No Gp3.003.03.0.Pr , Camtone Wheel For Crdi Cart Part No Gp3.003.07.0.Pr , Camshaft Assembly Cart Part No Gp3.003.10.0.Pr , Piston Assembly Cart Part No Gp3.004.10.0.Pr , Piston Assembly Cart Part No Gp3.004.130.0.Pr , Connecting Rod Asslywith Small End Bush Cart Part No Gp3.004.20.0.Pr , Small End Bushbimetal Bearings Ltd Cart Part No Gp3.004.22.0.Pr , Connecting Rod Bearing Upperbimetal Bearings Ltd Cart Part No Gp3.004.23.0.Pr , Connecting Rod Bearing Lowerbimetal Bearings Ltd Cart Part No Gp3.004.24.0.Pr , Cylinder Head Bolt Cart Part No Gp3.005.08.0.Pr , Engine Valve Intake4 Valve Cart Part No Gp3.005.11.0.Pr , Cylinder Head Sub Assembly (With Valve Seats & Inserts) Cart Part No Gp3.005.110.0.Pr , Engine Valve Exhaust4 Valve Cart Part No Gp3.005.12.0.Pr , Valve Stem Seal Cart Part No Gp3.005.17.0.Pr , Cylinder Head Gasket Cart Part No Gp3.005.19.0.Pr , Cylinder Head Assembly With Valves And Springs Cart Part No Gp3.005.30.0.Pr , Valve Guide With Snap Ring Assembly Cart Part No Gp3.005.50.0.00 , Pushrod (2 Valve, Welded) Cart Part No Gp3.006.01.0.Pr , Tappet Cart Part No Gp3.006.04.0.Pr , Rocker Lever Assembly Complete Cart Part No Gp3.007.50.0.Pr , Rocker Lever Assembly Complete Cart Part No Gp3.007.60.0.Pr , Relief Valve Cart Part No Gp3.008.08.0.Pr , Shaft For Lop Intermediate Gear Cart Part No Gp3.008.11.0.Pr , Washer (For L. O. P. Intermediate Gear) Cart Part No Gp3.008.12.0.Pr , O Ringfor Lub Oil Pump Cart Part No Gp3.008.13.0.Pr , Socket Head Grub Screw M14 Cart Part No Gp3.008.15.0.Pr , Lop With Relife Valve Assembly Cart Part No Gp3.008.50.0.Pr , Intermediate Gear Support Cart Part No Gp3.009.03.0.Pr , Thrust Washer For Intermediate Gear Cart Part No Gp3.009.04.0.Pr , Fip Gear Cart Part No Gp3.009.05.0.Pr , Adapter (For Fuel Pump Gear) Cart Part No Gp3.009.06.0.Pr , Sub Assembly Of Intermediate Gear Cart Part No Gp3.009.10.0.Pr , Gear Cover Cart Part No Gp3.010.01.0.Pr , Fip Cover Plate Cart Part No Gp3.010.03.0.Pr , O Ring For Fip Cover Plate Cart Part No Gp3.010.06.0.Pr , Oil Seal Cart Part No Gp3.010.09.0.Pr , Flanged Bolt (M6x1x070) Cart Part No Gp3.010.13.0.Pr , Gear Cover Cart Part No Gp3.010.14.0.Pr , Cam Housing (For Fuel Pump) Cart Part No Gp3.011.01.0.Pr , Cam Shaft (For F.I.P.) Cart Part No Gp3.011.02.0.Pr , Fuel Pump Cart Part No Gp3.011.06.0.Pr , Pin (For Link) Cart Part No Gp3.011.08.0.Pr , Dowel Pin (Rack Side) Cart Part No Gp3.011.102.0.00 , Oil Supply Pipe (Crankcase To F.I.P.) Cart Part No Gp3.011.12.0.Pr , Front Cover (For Fip) Cart Part No Gp3.011.13.0.Pr , O Ring (Front Cover Fip) Cart Part No Gp3.011.14.0.Pr , Stop Lever Cart Part No Gp3.011.16.0.Pr , Arm (Stop Lever) Cart Part No Gp3.011.17.0.Pr , Oringside Cover Fip Cart Part No Gp3.011.21.0.Pr , Back Cover ( For Fip) Cart Part No Gp3.011.22.0.Pr , O Ring (Back Cover Fip) Cart Part No Gp3.011.23.0.Pr , Bracket (For Fip) Cart Part No Gp3.011.24.0.Pr , Cover (Feed Pump) Cart Part No Gp3.011.25.0.Pr , O Ring (Feed Pump Cover) Cart Part No Gp3.011.26.0.Pr , Drain Plug For F.I.P. Cart Part No Gp3.011.27.0.Pr , O-Ring (For Drain Plug) Cart Part No Gp3.011.28.0.Pr , Side Cover (For Fip) Cart Part No Gp3.011.29.0.Pr , Stud (For F.I.P.) Cart Part No Gp3.011.31.0.Pr , Stud (For Side Cover Plate) Cart Part No Gp3.011.32.0.Pr , O Ring (For Stop Lever Shaft) Cart Part No Gp3.011.34.0.Pr , Lock Nut (For F.I.P.) Cart Part No Gp3.011.36.0.Pr , Cylindrical Roller Bearing-Nu205ecp (D-52, D-25,B-15) Cart Part No Gp3.011.38.0.Pr , Stud For F.I.P(M8x1.25) Cart Part No Gp3.011.39.0.Pr , Cb18 Fuel Pump Cart Part No Gp3.011.41.0.Pr , Fuel Pump Assembly Cart Part No Gp3.011.410.0.Pr , Oil Supply Pipecrankcase To F I P Cart Part No Gp3.011.44.0.Pr , Linear Actuator Cart Part No Gp3.011.47.0.Pr , Shaft (For Stop Lever Arm) Cart Part No Gp3.011.51.0.Pr , Torsional Spring Cart Part No Gp3.011.52.0.Pr , Spacer For Stop Lever Cart Part No Gp3.011.53.0.Pr , Fuel Pump Assembly Cart Part No Gp3.011.530.0.Pr , Oil Seal Housing For Fip (20X52x10) Cart Part No Gp3.011.59.0.00 , Fuel Pump Cart Part No Gp3.011.67.0.Pr , Pin (For Actuator Side) Cart Part No Gp3.011.95.0.Pr , Pin (For Fip Rack Side) Cart Part No Gp3.011.96.0.00 , Pin (For Link) Cart Part No Gp3.011.97.0.Pr , Link (Electronic Governor) Cart Part No Gp3.011.98.0.Pr , O Ring For Hydraulic Pump Adaptor Cart Part No Gp3.012.03.0.Pr , Oil Filling Adapter Cart Part No Gp3.012.05.0.Pr , O-Ring(For Oil Filling Cap) Cart Part No Gp3.012.07.0.Pr , O-Ring(For Breather Adaptor) Cart Part No Gp3.012.09.0.Pr , Cover Plate(For Gear Casing Hydraulic Side) Cart Part No Gp3.012.12.0.Pr , Gear Casingfor Mechanical F I P Cart Part No Gp3.012.13.0.Pr , Cover Plate For Gear Casing Cart Part No Gp3.012.14.0.Pr , Rotary Make Feed Pump 100Lph Cart Part No Gp3.012.87.0.Pr , Injector Clamp Cart Part No Gp3.013.04.0.00 , P Type Injector For R550 Engine Cart Part No Gp3.013.14.0.Pr , P-Type Injector For R550 Engine Cart Part No Gp3.013.25.0.Pr , P-Type Injector For R550 Engine Cart Part No Gp3.013.32.0.Pr , Intake Manifold Cart Part No Gp3.014.01.0.Pr , Gasket For Intake Manifold Cart Part No Gp3.014.02.0.Pr , Intake Manifold Cover Cart Part No Gp3.014.03.0.Pr , Gasket For Intake Manifold Cover Cart Part No Gp3.014.04.0.Pr , Joint For Intake Adaptor Cart Part No Gp3.014.07.0.Pr , Spacer Between Inlet Manifold & Air Intake Adaptor Cart Part No Gp3.014.11.0.Pr , Gasket For Intake Manifold Cart Part No Gp3.014.13.0.Pr , Stud (For Intake Manifold) Cart Part No Gp3.014.14.0.Pr , R550 Flange Heater With Same Side Connection Studs Cart Part No Gp3.014.16.0.Pr , High Pressure Pipefor Cyl 3 Cart Part No Gp3.015.100.0.Pr , High Pressure Pipefip To Common Rail Cart Part No Gp3.015.120.0.Pr , High Pressure Pipefip To Common Rail Cart Part No Gp3.015.130.0.Pr , High Pressure Pipe Assembly Cart Part No Gp3.015.160.0.Pr , High Pressure Pipe Assembly Cart Part No Gp3.015.40.0.Pr , High Pressure Pipefor Cyl 1 Cart Part No Gp3.015.70.0.Pr , Hp Pipeintegral Sleeve Assly Cart Part No Gp3.015.90.0.Pr , Rear Oil Seal Housing Cart Part No Gp3.016.01.0.Pr , Oil Seal Cart Part No Gp3.016.02.0.Pr , O Ring For Oil Seal Housing Cart Part No Gp3.016.04.0.Pr , O Ringfor Suction Tube Adaptor Cart Part No Gp3.017.07.0.Pr , Suction Tube Assembly Cart Part No Gp3.017.12.0.Pr , Lub Oil Sump Sub Assembly Cart Part No Gp3.019.10.0.Pr , Flywheel Housing Sae4 Width - 105 Cart Part No Gp3.020.01.0.Pr , Cover Plate For Sensor Cart Part No Gp3.020.06.0.Pr , Timing Pointer Assembly Cart Part No Gp3.020.08.0.Pr , Flywheel Housing Sae4-Width 105 Cart Part No Gp3.020.09.0.Pr , Flywheel & Starter Ring Assembly Cart Part No Gp3.021.10.0.Pr , Starter Ring Cart Part No Gp3.021.11.0.Pr , Flywheel Starter Ring Assembly Cart Part No Gp3.021.110.0.Pr , Flywheel Bolt (M12x1.25X30) Cart Part No Gp3.021.12.0.Pr , Flywheel & Starter Ring Assembly Cart Part No Gp3.021.50.0.Pr , Startor Cart Part No Gp3.022.01.0.Pr , Header Cart Part No Gp3.024.02.0.Pr , O Ring (Dia 19X2) Cart Part No Gp3.024.03.0.Pr , O Ring (Dia 61X3) Cart Part No Gp3.024.04.0.Pr , Oil Filter Cart Part No Gp3.024.05.0.Pr , Dipstick Assemblywith Knob Cart Part No Gp3.025.10.0.Pr , Gasket For Exhaust Manifold Cart Part No Gp3.029.02.0.Pr , Gasketfor Turbo To Exhaust Manifold Cart Part No Gp3.029.06.0.Pr , Spacer (For Exhaust Manifold) Cart Part No Gp3.029.07.0.Pr , Gasket Exhaust Manifold To Egr Cooler Cart Part No Gp3.029.09.0.Pr , Gasketfor Turbo To Exhaust Manifold Cart Part No Gp3.029.11.0.Pr , Spacerfor Exhaust Manifold Cart Part No Gp3.029.12.0.Pr , Exhaust Manifold Cart Part No Gp3.029.15.0.Pr , Exhaust Manifold Cart Part No Gp3.029.18.0.Pr , Turbo Charger For Tc Versioncpcb Ii Cart Part No Gp3.030.13.0.Pr , Improved Efficiency Turbocharger For 3R550ta (Mechanical) Cpcb 4+ 25.5Hp@1500R Cart Part No Gp3.030.14.0.Pr , Turbocharger Cart Part No Gp3.030.15.0.Pr , Alternator Support Bracket Ch (On Cylinder Head) Cart Part No Gp3.031.01.0.Pr , Alternator Support Bracket Cart Part No Gp3.031.02.0.Pr , Alternator Pulley (P.C.D.68) Cart Part No Gp3.031.05.0.Pr , Water Pump Sleeve Cart Part No Gp3.032.07.0.Pr , O Ringfor Water Pump Sleeve Cart Part No Gp3.032.08.0.Pr , Water Pump Joint Cart Part No Gp3.032.11.0.Pr , Water Pump Assembly Cart Part No Gp3.032.50.0.Pr , Washer (For Crank Pulley Bolt) Cart Part No Gp3.033.02.0.Pr , Crank Pulley (Pcd 110) Cart Part No Gp3.033.04.0.Pr , Water Pump Pulley (Pcd 86) Cart Part No Gp3.033.08.0.Pr , Poly V-Belt Cart Part No Gp3.033.11.0.Pr , Thermostat Cover Cart Part No Gp3.034.01.0.Pr , Gasket For Thermostat Cover Cart Part No Gp3.034.02.0.Pr , Thermostat Element Cart Part No Gp3.034.03.0.Pr , Rocker Cover Cart Part No Gp3.035.01.0.Pr , Blow By Adaptor (For Closed Breather System) Cart Part No Gp3.035.02.0.Pr , Gromet For Rocker Cover Bolt Cart Part No Gp3.035.04.0.Pr , Cap For Rocker Cover Bolt Gromet Cart Part No Gp3.035.05.0.Pr , Oil Filling Cap (Plastic) Cart Part No Gp3.035.06.0.Pr , Sealing Washer (For Oil Filling Cap) Cart Part No Gp3.035.07.0.Pr , Gasket For Rocker Cover Cart Part No Gp3.035.08.0.Pr , Bolt For Rocker Cover Cart Part No Gp3.035.09.0.Pr , Oil Separator Cart Part No Gp3.035.11.0.Pr , O-Ring (For Closed Breather Adaptor) Cart Part No Gp3.035.12.0.Pr , Gasket For Rocker Cover Cart Part No Gp3.035.14.0.Pr , O Ringfor Rocker Cover Cart Part No Gp3.035.15.0.Pr , Rocker Cover Cart Part No Gp3.035.16.0.Pr , Radiator Pipe Cart Part No Gp3.035.36.0.Pr , Adaptorm12x1 5X11lfor Water Heater Hose Cart Part No Gp3.035.38.0.Pr , Breather Hose Cart Part No Gp3.036.02.0.Pr , Air Cleaner Assembly Cart Part No Gp3.037.18.0.Pr , Air Cleaner Mounting Bracket Cart Part No Gp3.037.34.0.Pr , Air Cleaner Hose Cart Part No Gp3.037.37.0.Pr , Hose For Air Cleaner Cart Part No Gp3.037.38.0.Pr , Bracket For Air Cleaner Cart Part No Gp3.037.39.0.Pr , Dry Type Air Cleaner Assly For R550 Cart Part No Gp3.037.40.0.Pr , Air Cleaner Hose Cart Part No Gp3.037.43.0.Pr , Air Cleaner Hose To Turbo Cart Part No Gp3.037.78.0.Pr , Hose For Air Suction Cart Part No Gp3.037.98.0.Pr , Joint For Exhaust System Cart Part No Gp3.038.04.0.Pr , Expansion Bellow With Pipe From Manifold To Silencer (Gp3-15Kva) Cart Part No Gp3.038.08.0.Pr , Silencer For 3R550 2R550 Cart Part No Gp3.038.10.0.Pr , Exhaust Pipe (Bellow Out To Silencer I Cart Part No Gp3.038.103.0.Pr , Silencer Assembly Cart Part No Gp3.038.15.0.Pr , Joint Exhaust Bend Cart Part No Gp3.038.16.0.Pr , Exhaust Pipe With Bellow (Turbo Out To Sil In) Cart Part No Gp3.038.22.0.Pr , Exhaust Pipe With Bellow (Exhaust Manifold To Silencer) Cart Part No Gp3.038.51.0.Pr , Joint Cart Part No Gp3.038.66.0.Pr , Exhaust Pipe With Bellow (3R550tc) Cart Part No Gp3.038.67.0.Pr , Exhaust Pipe (Turbo Out To Bellow In) Cart Part No Gp3.038.99.0.Pr , Fan For R550 Radiatordia 380Mm Cart Part No Gp3.039.04.0.Pr , Spacer For Fan Cart Part No Gp3.039.05.0.Pr , Fan For R550 Radiator Cart Part No Gp3.039.06.0.Pr , Lifting Hook Cart Part No Gp3.040.01.0.Pr , Gp3.041.07.0.Pr_Pipe (Turbo Side) Cart Part No Gp3.041.07.0.Pr , Hose Cart Part No Gp3.041.08.0.Pr , Cac Hosecold Side Cart Part No Gp3.042.02.0.Pr , Cac Hosecold Side Cart Part No Gp3.042.05.0.Pr , Cac Hosehot Side Cart Part No Gp3.043.02.0.Pr , Hoseturbo Side Cart Part No Gp3.043.08.0.Pr , Hoseturbo Side Cart Part No Gp3.043.14.0.00 , Cac Pipe ( Hot Side) Cart Part No Gp3.043.15.0.00 , Cac Hoseradiator Side Cart Part No Gp3.043.16.0.Pr , Packing Foot For R550 Cart Part No Gp3.045.76.0.Pr , Engine Mounting Foot For R550 Cart Part No Gp3.045.79.0.Pr , Engine Mounting Foot For R550 Cart Part No Gp3.045.81.0.Pr , Spacer Between Engine Foot Crank Case Cart Part No Gp3.045.82.0.Pr , Gasketfor Turbo To Oil Drain Pipe Cart Part No Gp3.046.01.0.Pr , Adaptor (For Turbo Oil Inl Cart Part No Gp3.046.08.0.Pr , O Ring For Turbo Oil Suppy Pipe Adaptor Cart Part No Gp3.046.13.0.Pr , Drain Pipe Assy (For Turbo Charger) Cart Part No Gp3.046.14.0.Pr , Turbo Drain Pipe Assy (For Turbo Charger) Cart Part No Gp3.046.19.0.Pr , Adaptor With Hose Tail For Sump Drain Cart Part No Gp3.046.22.0.Pr , Turbo Oil Supply Pipe (Turbo Side) Cart Part No Gp3.046.29.0.Pr , Turbo Oil Supply Pipe (Crankcase Side) Cart Part No Gp3.046.31.0.Pr , Turbo Oil Supply Pipecrankcase Side Cart Part No Gp3.046.32.0.Pr , Fuel Filter Assembly. Cart Part No Gp3.047.01.0.Pr , Fuel Pipefuel Filter To F I P Cart Part No Gp3.047.02.0.Pr , Filter To Fip Cart Part No Gp3.047.09.0.Pr , 50 Hrs - A Check Maintenance Kit Cart Part No Gp3.047.11.0.Sp , 1500 Hrs - C Check Maintenance Kit Cart Part No Gp3.047.14.0.Sp , Fuel Filter Cart Part No Gp3.047.16.0.Pr , Spinon Fuel Filter Cart Part No Gp3.047.55.0.Pr , Leak Off Pipepolyamide Cart Part No Gp3.048.01.0.Pr , Leak Off Pipe Assembly Cart Part No Gp3.048.05.0.Pr , Leak Off Pipe Assembly For Fip Side Cart Part No Gp3.048.11.0.Pr , Common Rail Cart Part No Gp3.049.01.0.Pr , Mixer (Foregr ) Cart Part No Gp3.050.01.0.Pr , Hose Mixer To Throttle Body Cart Part No Gp3.050.02.0.Pr , Mixer Plate ( For Egr) Cart Part No Gp3.050.03.0.Pr , Gasketbetween Egr Valveegr Pipe Cart Part No Gp3.050.04.0.Pr , Gasket Between Egr Mixer And Egr Valve Cart Part No Gp3.050.05.0.Pr , Stud (For Egr Valve) Cart Part No Gp3.050.06.0.Pr , Stud (For Egr Valve) Cart Part No Gp3.050.07.0.Pr , Hose (Mixer For Egr To Pipe) Cart Part No Gp3.050.09.0.Pr , Hose Egr Valveto Crankcase Cart Part No Gp3.050.11.0.Pr , Hoseegr Valve To Cy Head Cart Part No Gp3.050.12.0.Pr , Between Egr Valve And Egr Pipe Cart Part No Gp3.050.14.0.Pr , Gp3.050.15.0.Pr_Hose Cart Part No Gp3.050.15.0.Pr , Mixer (Foregr ) Cart Part No Gp3.050.18.0.Pr , Intake Pipe Cart Part No Gp3.050.19.0.Pr , Mixer Plate Cart Part No Gp3.050.21.0.Pr , O Ring Cart Part No Gp3.050.22.0.Pr , Bracket For Hose Cart Part No Gp3.050.23.0.Pr , Bracket For Hose Cart Part No Gp3.050.24.0.Pr , Egr Pipe Cart Part No Gp3.054.02.0.Pr , Hose Egr Valve Water Inlet Cart Part No Gp3.055.07.0.Pr , Hose Egr Valve Water Outlet Cart Part No Gp3.055.08.0.Pr , Egr Cooler 5 Kw Cart Part No Gp3.055.13.0.Pr , Diesel Oxidation Catalystdocgp3 056 01 Cart Part No Gp3.056.01.0.Spr , Gasket Between Doc Pipe And Doc Cart Part No Gp3.056.05.0.Pr , Expansion Bellow Cart Part No Gp3.056.07.0.Pr , Heat Shield Cart Part No Gp3.058.03.0.Pr , Hose For Breather System Cart Part No Gp3.062.02.0.Pr , Hose For Breather Cart Part No Gp3.062.06.0.Pr , Charging Alternetor Cart Part No Gp3.100.01.0.Pr , 3R550 Engine Ecuag48 Cart Part No Gp3.100.02.0.Pr , Ecu (Ag48), For Pg Specific Application Cart Part No Gp3.100.03.0.Pr , Ecu Mounting Bracket Cart Part No Gp3.100.05.0.Pr , 3R550 Engine Ecu (Ag48) Cart Part No Gp3.100.21.0.Pr , Support Plate Cart Part No Gp3.107.01.0.Pr , U Clamp Cart Part No Gp3.107.02.0.Pr , Hose For Radiator Cart Part No Gp3.107.04.0.Pr , Hose For Radiator Cart Part No Gp3.107.05.0.Pr , Hose From Thermostat To Radiator Cart Part No Gp3.107.06.0.Pr , Suction Hose Cart Part No Gp3.107.12.0.Pr , Support Plate Cart Part No Gp3.107.18.0.Pr , Radiator For R550 Genset Cart Part No Gp3.107.23.0.Pr , Pipe (Radiator To Pump Inlet) Cart Part No Gp3.107.34.0.Pr , Hose From Thermostat To Radiator Cart Part No Gp3.107.36.0.Pr , Radiator Assembly For R550 Cart Part No Gp3.107.97.0.Pr , Fuel Pipe From Pre Filter To Feed Pump Cart Part No Gp3.108.01.0.Pr , Electric Feed Pump And Fuel Filter Mounting Bracket Cart Part No Gp3.108.05.0.Pr , Fuel Pipe From Tank To Filter Cart Part No Gp3.108.06.0.Pr , Fuel Tank Unit S/F 95 Effective Tank Height Cart Part No Gp3.108.07.0.Pr , Fuel Inlet Pipe (Tank To Pump) Cart Part No Gp3.108.101.0.Pr , Fuel Inlet Pipe (Tank To Feed Pump) Cart Part No Gp3.108.102.0.Pr , Adaptorm16 X 1 5 To M22 X 1 5 Cart Part No Gp3.108.14.0.Pr , Fuel Pipe From Tank To Pre Filter Cart Part No Gp3.108.141.0.Pr , Fuel Pipe From Pre Filter To Main Filter Cart Part No Gp3.108.142.0.Pr , Adaptor (M22x1.5 & M14x1.5) Cart Part No Gp3.108.149.0.Pr , Top Clampfor Electric Pump Cart Part No Gp3.108.16.0.Pr , Lower Clamp (For Electric Pump) Cart Part No Gp3.108.17.0.Pr , Fuel Pipe From Tank To Pump Cart Part No Gp3.108.19.0.Pr , Fuel Pipe Electric Pump To Tank Unit Cart Part No Gp3.108.56.0.Pr , Fuel Pipefrom Tank To Pump Cart Part No Gp3.108.57.0.Pr , Anti Vibration Mount Cart Part No Gp3.110.07.0.Pr , Can Display Unit For R550 Cart Part No Gp3.119.05.0.Pr , Kg645 C Controller Unit R550 (Sp-3 Hardware 12V) Cart Part No Gp3.210.17.0.Pr , Battery Cable R550 Cart Part No Gp3.210.30.0.Pr , Engine Wiring Harness For 3R550ta Crdi Cpcb4 Cart Part No Gp3.211.10.0.Pr , Control Panel Electrical Schematic For 25Kva 1 Ph 3R550 Cpcb4 Cart Part No Gp3.211.80.0.Pr , 48V Terminal Box Assembly Cart Part No Gp3.212.10.0.Pr , Electrical Scheamatic For 15Kva3ph 3R550 With Kg645c Cart Part No Gp3.221.40.0.Pr , Electrical Scheamatic For 15Kva1ph 3R550 With Kg645c Cart Part No Gp3.221.50.0.Pr , Engine Wiring Harness 3R550 Engine With Ag48 And Kg645c Cart Part No Gp3.221.60.0.Pr , Engine Wiring Harness 3R550 Engine With Ag48 And Kg645c Cart Part No Gp3.221.80.0.Pr , Control And Power Panel Assembly For 25 Kva 1Ph Cpcb4 Cart Part No Gp3.222.30.0.Pr , Control Panel Assembly For 15 Kva 3Ph Cpcb4 Cart Part No Gp3.227.60.0.Pr , Control Panel Assembly For 15Kva 1Ph Cpcb4 Cart Part No Gp3.228.20.0.Pr , Control Panel Assembly Cart Part No Gp3.229.30.0.Pr , Super Capacitor To Starter Harness Cart Part No Gp3.230.30.0.Pr , Mccb 125A 2P 25Ka Cart Part No Gp3.230.41.0.Pr , Super Capacitor Module 48V Cart Part No Gp3.230.61.0.Pr , Procom Controller ,Model-Econ-Abt-Rel Cart Part No Gp3.230.62.0.Pr , Fuel Level Sensor Cart Part No Gp3.230.65.0.Pr , Flexible Coupling Disc Kg 42.3 Sae 7.5_Ag424059 R00 Cart Part No Gp3.230.67.0.Pr , Cold Start Kit Main Assembly For L2 Level Application(3R550) Cart Part No Gp3.232.50.0.Sp , Cold Start Sub Assembly 3R550 Cart Part No Gp3.233.50.0.Pr , Water Heater Connections Metal Pipe Cart Part No Gp3.478.01.0.Pr , Rubber Hosefor Water Heater Cart Part No Gp3.478.04.0.Pr , Clamping Bracket Cart Part No Gp3.507.03.0.Pr , 1500 Hrs C Check Maintenance Kit Gp3 8601Gp3 1021Gp3 8604 Cart Part No Gp3.860.01.0.Sp , K350 Avr Cart Part No Gp3.901.22.0.00 , Koel Alternator 15 Kva 3Ph 415V 0 8P F 50 Hzsae 47 5 Frame Kg40 E Cart Part No Gp3.901.62.0.Pr , Koel Green Alternator 20Kva 3Ph 415V 50Hz Sae4 7 5 Cart Part No Gp3.901.63.0.Pr , Koel Green Alternator 25Kva 3Ph 415V 50Hz Sae4 7 5 Cart Part No Gp3.901.82.0.Pr , Terminal Bar 2 Stud Cart Part No Gp3.902.24.0.Pr , Battery Cable 50 Sqmm 1350Mm Cart Part No Gp3.913.60.0.Pr , Water Jacket Heater Harness Cart Part No Gp3.913.70.0.Pr , Piston Ring Set Cart Part No Gp3.999.02.0.Sp , Inlet Exhaust Valve Pair Cart Part No Gp3.999.03.0.Sp , Main Bearing Pair R550 Cart Part No Gp3.999.10.0.Sp , Fip Timing Tool For F Series Cart Part No Gp3.999.107.0.Esp , Box Type Fip Spanner 135Mm For 3R550 Cart Part No Gp3.999.109.0.Sp , Thrust Washer Set R550 Cart Part No Gp3.999.11.0.Sp , S Type Fip Spanner For 2R550 & 3R550 Cart Part No Gp3.999.110.0.Sp , Puller For Fip Hub Removal 2R550 & 3R550 Cart Part No Gp3.999.111.0.Sp , Connecting Rod Bearing R550 Cart Part No Gp3.999.12.0.Sp , Piston Assembly For Gp3.1009, Engine Cart Part No Gp3.999.18.0.Sp , Wet Pm Kit (W/O Oil) For Gp3.8006.Pb - 3R550nag1 Cart Part No Gp3.999.25.0.Sp , Wet Pm Kit (W/O Oil ) For Gp3.8601 Cart Part No Gp3.999.52.0.Sp , Wet Pm Kit (W/O Oil) For Gp3.8006 - 3R550nag1 Cart Part No Gp3.999.78.0.Sp , Bracket For R550 (3 Cyl Engine) Cart Part No Gp3.999.92.0.Sp , Valve Bridge4 Valve Cart Part No Gp4.005.11.0.00 , Oil Cooler Cart Part No Gp4.023.01.0.Pr , O Ring For Oil Cooler Cart Part No Gp4.023.02.0.Pr , Oil Cooler Nine Plate Cart Part No Gp4.023.03.0.Pr , Oil Separator Cart Part No Gp4.035.11.0.Pr , Con Rod Bearing: Pair Ra3 Cart Part No H.038.4.00.003 , Con Rod Bearing Pair: Ra3 Cart Part No H.038.4.00.013 , Con Rod Bearing Pair: Ra3 Cart Part No H.038.4.00.023 , Con Rod Bearing: Ha394 Cart Part No H.073.4.00.003 , Con Rod Bearing: Ha394 Cart Part No H.073.4.00.013 , Con Rod Bearing: Ha394 Cart Part No H.073.4.00.023 , Bearing C/R Cart Part No H.073.4.00.033 , Con Rod Brg Ha394 Std Pair Cart Part No H.073.4.10.003 , Con Rod Bearing Ha3940.25 Pair Cart Part No H.073.4.10.013 , Con Rod Bearing: Ha394 020 U/S Pair Nick Cart Part No H.073.4.10.023 , Bearing C Rkir Ha 3940 75 Pair Nick Cart Part No H.073.4.10.033 , Bearing C/Rkir Ha 394, 1.00 Pair, (Nick) Cart Part No H.073.4.10.043 , Connecting Rod Bearing Pair Cart Part No H.547.4.00.003 , Con Rod Bearing Pair Cart Part No H.553.4.00.003 , O Ring For Side Cover Plate Cart Part No K12.001.18.0.Pr , O Ring For Sealing Plug Cart Part No K12.001.21.0.Pr , O Ring For Cam Cover Cart Part No K12.001.25.0.Pr , Gasket For Top Cover Plate Cart Part No K12.001.27.0.Pr , Dowel Pin For Cylinder Head Cart Part No K12.001.31.0.Pr , O Ring For Relief Valve Cover Plate Cart Part No K12.001.33.0.Pr , Oil Spray Nozzle Cart Part No K12.001.61.0.Pr , O Ring Cart Part No K12.002.02.0.Pr , Scraper Ring Cart Part No K12.002.03.0.Pr , Cylinder Liner Assembly Cart Part No K12.002.10.0.Pr , O Ring For Crank Gear Cart Part No K12.003.05.0.Pr , Connecting Rod Bolt Cart Part No K12.005.02.0.Pr , Piston Ring Set For K4300 Cart Part No K12.005.03.0.Sp , Circlip Cart Part No K12.005.08.0.Pr , Piston Assembly Cart Part No K12.005.10.0.Pr , Conrod Bearing Upper Half Cart Part No K12.005.11.0.Pr , Conrod Bearing Lowerhalf Cart Part No K12.005.12.0.Pr , Push Rod Assembly Cart Part No K12.006.40.0.Pr , Fulcrum Lever Assembly Cart Part No K12.006.50.0.Pr , Inlet Valve Cart Part No K12.007.02.0.Pr , Exhaust Valve Cart Part No K12.007.03.0.Pr , Valve Spring Outer Cart Part No K12.007.04.0.Pr , Valve Spring Inner Cart Part No K12.007.06.0.Pr , Main Cylinder Head Bolt Cart Part No K12.007.07.0.Pr , Inlet Valve Seat Insert (Semifinish) Cart Part No K12.007.08.9.Pr , Exhaust Valve Seat Insert(Semifinish) Cart Part No K12.007.09.9.Pr , Valve Guide - Semifinish Cart Part No K12.007.11.9.Pr , Bridge For Rocker Arm Cart Part No K12.007.13.0.Pr , Valve Rotator Cart Part No K12.007.14.0.Pr , Fire Ring3 Thkfor Cylinder Head Gasket Cart Part No K12.007.15.0.Pr , Fire Ring3 25 Thkfor Cylinder Head Gasket Cart Part No K12.007.16.0.Pr , Nozzle Clamp Cart Part No K12.007.18.0.Pr , Cup Washer For Nozzle Clamp Cart Part No K12.007.21.0.Pr , Valve Collet Cart Part No K12.007.24.0.Pr , Auxilary Cylinder Head Bolt Cart Part No K12.007.26.0.Pr , Cylinder Head Gasketfor 3 Thk Fire Ring Cart Part No K12.007.28.0.Pr , Nut For Feed Tube Cart Part No K12.007.32.0.Pr , Rocker Lever Assemblycomplete Cart Part No K12.008.70.0.Pr , Gasket For Rocker Cover Cart Part No K12.009.02.0.Pr , O Ringfor Gear Casing Cart Part No K12.010.03.0.Pr , O Ring For Intermediate Double Gear Support Cart Part No K12.011.02.0.Pr , Lop Assembly With Geargear Ratio 1 4 Cart Part No K12.012.170.0.Pr , O Ring For Sea Water Pump Cover Cart Part No K12.013.05.0.Pr , O Ring For Fuel Pump Cover Plate Cart Part No K12.013.07.0.Pr , O Ringcs 2 X 11 Id For Water Pump Sleeve Assy Cart Part No K12.013.12.0.Pr , O Ring For Fip Gear Support Cover Cart Part No K12.013.19.0.Pr , O Ring Bw Housing And Fornt Cover Cart Part No K12.014.08.0.Pr , O Ringfor Water Pump Suction Pipe Cart Part No K12.014.09.0.Pr , Water Pump Assemblytaper Shaft Cart Part No K12.014.60.0.Pr , Gasket For Water Pump Volute Cart Part No K12.015.02.0.Pr , O Ring For Suction Pipe Cover Plate Cart Part No K12.016.03.0.Pr , O Ring For Thermostat Pipe Sleeve Cart Part No K12.016.05.0.Pr , Suction Pipe For Water Pump Cart Part No K12.016.06.0.Pr , O-Ring For Water Pump Suction Pipe Volute Side Cart Part No K12.016.07.0.Pr , O-Ring For Water Pump Suction Cart Part No K12.016.08.0.Pr , Thermostat Cart Part No K12.017.02.0.Pr , Gasket Between Thermostat Housing And Gear Casing Cart Part No K12.017.06.0.Pr , O Ringfor Thermostat Cart Part No K12.017.07.0.Pr , Seal Ring (For Thermostat Element) Cart Part No K12.017.09.0.Pr , Housing For Thermostat Out Cart Part No K12.017.11.0.Pr , O Ring For Thermostat Out Adaptor Cart Part No K12.017.12.0.Pr , Gasketfor Thermostat Housing Cart Part No K12.017.13.0.Pr , Filter Header O Ring Cart Part No K12.018.02.0.Pr , O Ring For Sleevefor Oil And Cooler Header Cart Part No K12.018.05.0.Pr , Gasketfor Lub Oil Header Cart Part No K12.018.06.0.Pr , Gasket For Oil Cooler Header Cover Cart Part No K12.018.09.0.Pr , Oil Cooler Cart Part No K12.018.12.0.Pr , O Ring For Oil Cooler Cart Part No K12.018.13.0.Pr , Dome Nut O Ringfor Oil Cooler Cart Part No K12.018.15.0.Pr , Lube Filter, Spin On Cart Part No K12.018.27.0.Pr , Adaptorfor Bypass Filter Cart Part No K12.019.02.0.Pr , Gasketfor Bypass Filter Cart Part No K12.019.03.0.Pr , Fuel Injection Pump Lhs Cart Part No K12.020.10.0.Pr , Fip For K12 N16299m Rhs From Gear End Cart Part No K12.021.10.0.Pr , Fuel Filter Assembly Cart Part No K12.022.02.0.Pr , Bracket For Fuel Filter Cart Part No K12.022.06.0.Pr , Fuel Filter Spin On Cart Part No K12.022.07.0.Pr , Gasket For Cover Plate Cart Part No K12.023.03.0.Pr , O Rings C 4 X 145 Id Cart Part No K12.023.05.0.Pr , Gasketfor Inlet Manifold Cart Part No K12.023.13.0.Pr , Cac Adaptorrhs From Fwe Cart Part No K12.023.14.0.Pr , Cac Adaptorlhs From Fwe Cart Part No K12.023.15.0.Pr , Hose For Cac Pipeid 151 X Id 151 Cart Part No K12.023.61.0.Pr , Joint (For Breather Plate) Cart Part No K12.024.04.0.Pr , O-Ring Dia 3Mm,Id 60 (For Breather Cover Plate) Cart Part No K12.024.06.0.Pr , Breather Hose (Rh Side From Fwe) Cart Part No K12.024.31.0.Pr , Breather Hose Cart Part No K12.024.32.0.Pr , Expansion Bellow Cart Part No K12.025.04.0.Pr , Gasketbetween Head Exhmanifold Cart Part No K12.025.06.0.Pr , Jointbetexhmanifold Expabellow Cart Part No K12.025.09.0.Pr , Jointbetween Turbocharger And Exhmanifold Cart Part No K12.025.11.0.Pr , Adaptor For B3ng Turbocharger (Rhs From Fwe) Cart Part No K12.026.17.0.Pr , Oil Supply Pipe For Tel Turbo Cart Part No K12.026.25.0.Pr , Adaptor For B3ng Turbochargerlhs From Fwe Cart Part No K12.026.36.0.Pr , O Ring B W Adaptor Turbocharger Cart Part No K12.026.38.0.Pr , Joint For Turbo Diffuser Cart Part No K12.026.39.0.Pr , Exhaust Diffuserfor B3ns Turbocharger Cart Part No K12.026.41.0.Pr , Turbocharger B3ns 180 Degfor 1500 Rpm Cart Part No K12.026.49.0.Pr , Turbocharger B3ns 23 Degfor 1500 Rpm Cart Part No K12.026.51.0.Pr , Joint Between T C And Drain Pipe Cart Part No K12.026.59.0.Pr , Oil Drain Pipe For Tel Turbocharger Cart Part No K12.026.64.0.Pr , Flange For Oil Drain Pipedouble O Ring Cart Part No K12.026.65.0.Pr , O Ring For Turbo Drain Pipe Flange Cart Part No K12.026.67.0.Pr , Air Cleaner Elbow Cart Part No K12.026.78.0.Pr , Main Cac Pipe Cart Part No K12.027.06.0.Pr , O-Ring Dia 3Mm, Id 108 Cart Part No K12.027.09.0.Pr , Sleevebetween Adaptor And Cac Pipe Cart Part No K12.027.101.0.Pr , O Ringfor Cac Pipe Sleeve Cart Part No K12.027.102.0.Pr , O Ring Dia 4Mmid 88 Cart Part No K12.027.11.0.Pr , O Ring Dia 4Mmid 125 Cart Part No K12.027.15.0.Pr , O Ring Dia 6Mmid 82 5 Cart Part No K12.027.23.0.Pr , Cac Pipe 2Lhs From Fwe Cart Part No K12.027.91.0.Pr , Cac Pipe 1Lhs From Fwe Cart Part No K12.027.93.0.Pr , Cac Pipe 1Rhs From Fwe Cart Part No K12.027.94.0.Pr , Cac Pipe 3Rhs From Fwe Cart Part No K12.027.97.0.Pr , Oil Seal For Fwesaint Gobain Cart Part No K12.028.14.0.Pr , Barring Assembly Cart Part No K12.028.40.0.Pr , O Ring For Oil Filling Cart Part No K12.031.03.0.Pr , O Ringbetween Sump And Crankcase Cart Part No K12.031.14.0.Pr , O Ring For Centrifuge Cart Part No K12.032.03.0.Pr , O Ring For Oil Flow Sleeve Cart Part No K12.032.05.0.Pr , O Ring For Centrifuge Housing Cart Part No K12.032.08.0.Pr , Single Centrifuge Assy Cart Part No K12.032.20.0.Pr , Rubber Sleevefor Hp Pipe Cart Part No K12.035.04.0.Pr , Upper Clampfor Od 20 Rubber Sleeve Cart Part No K12.036.07.0.Pr , Rubber Sleeveid 15 X Od 20 Cart Part No K12.036.08.0.Pr , Rubber Sleeveid 10 X Od 20 Cart Part No K12.036.09.0.Pr , Rubber Sleeveid 10 X Od 14 Cart Part No K12.036.12.0.Pr , Rubber Sleeveid 6 X Od 14 Cart Part No K12.036.13.0.Pr , Leak Off Pipe Rh Bankfrom Fwe Cart Part No K12.036.130.0.Pr , Lub Oil Supply Pipe Crankcase To Fip Rh Sidef G E Cart Part No K12.036.220.0.Pr , Fuel Pipe Feed Pump To Fuel Filter Lh Bank From Fwe Cart Part No K12.036.250.0.Pr , Fuel Pipe Feed Pump To Fuel Filter Lh Bank From Fwe Cart Part No K12.036.260.0.Pr , Fuel Pipe Feed Pump To Fuel Filter - Rh Bank From Fwe Cart Part No K12.036.270.0.Pr , Fuel Pipe Filter To Fip - Rh Bank From Fwe Cart Part No K12.036.280.0.Pr , Fuel Discharge Pipe Cart Part No K12.036.30.0.Pr , Rubber Sleeve O D 6 X O D 15 Cart Part No K12.036.35.0.Pr , Two Pipe Clamp O D 6 X O D 15 Cart Part No K12.036.36.0.Pr , Injector For K4300 Enginenozzle N16494a 2350 Htf 8 X 146 Cart Part No K12.037.10.0.Pr , Pipe For Bank Connection Cart Part No K12.039.02.0.Pr , Belt For Fandrive Powerband3 Av115x1904 Cart Part No K12.042.08.0.Pr , Belt Forfandrivepower Band 2 Av115x1904 Cart Part No K12.042.09.0.Pr , Governor Dc 12 Master Cart Part No K12.103.01.0.Pr , Magnetic Pick Up 16X1 5 Threading Cart Part No K12.103.02.0.Pr , Starter For K4300rh Cart Part No K12.103.22.0.Pr , Starter For K4300 (Lh) Cart Part No K12.103.23.0.Pr , Governor Dc 12 Slave Cart Part No K12.103.26.0.Pr , Kg 50 2 Rra Assembly 1250 To 1650Kva Cart Part No K12.103.40.0.Pr , Top Cover For Terminal Box K4300 Cart Part No K12.104.02.0.Pr , Differential Ct Assembly For 1250Kvaloose Supply Cart Part No K12.104.40.0.Pr , Copper Busbar Phase R Cart Part No K12.104.42.0.Pr , Copper Busbar Phase Y Cart Part No K12.104.43.0.Pr , Copper Busbar Phase B Cart Part No K12.104.44.0.Pr , Bus Bar Support From Bottom Cart Part No K12.104.46.0.Pr , Bus Bar Support From Top Cart Part No K12.104.47.0.Pr , Copper Busbar Neutral Cart Part No K12.104.48.0.Pr , Differential Ct Assembly For 1500Kvaloose Supply Cart Part No K12.104.50.0.Pr , Adaptor For Oil And Pressure Sensor Cart Part No K12.105.16.0.Pr , Silencer Assemblysilent Set Cart Part No K12.106.19.0.Pr , O-Ring Dia. 4Mm, Id 190 Cart Part No K12.107.07.0.Pr , Vent Pipe From Engine To Radiator Cart Part No K12.107.08.0.Pr , Vent Hose Cart Part No K12.107.09.0.Pr , Cac Pipeengine To Radiator In Cart Part No K12.107.101.0.Pr , Pipe From Thermostat To Radiator In Cart Part No K12.107.102.0.Pr , Cac Pipe Rh Side From F W Eradiator To Engine In Cart Part No K12.107.103.0.Pr , Cac Pipe Lh Side From F W Eradiator To Engine In Cart Part No K12.107.106.0.Pr , Suction Piperadiator To Engine In Cart Part No K12.107.107.0.Pr , Hose For Cac Pipeid 126 X Id 126 Cart Part No K12.107.12.0.Pr , Flexible Vent Pipemale Plug M14x1 5 And M14x1 5 Union Nut Cart Part No K12.107.13.0.Pr , Fair Radiator For K4300 1500 Kva Cart Part No K12.107.78.0.Pr , Hose From Turbo Outlet Cart Part No K12.108.04.0.Pr , Air Cleaner Pipe - 2 (Rh Side From Few) Cart Part No K12.108.29.0.Pr , Anti Vibration Mount -Raem 1500-60 Sh (Trelleborg) Cart Part No K12.110.02.0.Pr , Anti Vibration Mount -Raem 2500-60 Sh (Trelleborg) Cart Part No K12.110.04.0.Pr , Silencer Clamp For K12 Engine Cart Part No K12.114.11.0.Pr , Fuel Pipe From Pre Filter To Feed Pumpm18x1 5 Banjo Both Side Cart Part No K12.116.01.0.Pr , Fuel Inlet Pipe From Pre Filter To Junction Plate Cart Part No K12.116.02.0.Pr , Fuel Inlet Pipe From Pre Filter To Junction Plate Cart Part No K12.116.03.0.Pr , Fuel Return Pipe M22x1 5 Union Both Siderh Side From F W E Cart Part No K12.116.04.0.Pr , Fuel Return Pipe M22x1 5 Union Both Sidelh Side From F W E Cart Part No K12.116.05.0.Pr , Fuel Pipe M22x1 5 Union Both Sidefrom Junction Plate To Tank Cart Part No K12.116.06.0.Pr , Fuel Pipe From Pre Filter To Feed Pumpm18x1 5 Banjo Both Side Cart Part No K12.116.18.0.Pr , Fuel Inlet Pipe From Pre Filter To Tank Cart Part No K12.116.22.0.Pr , Fuel Return Pipem16x1.5 Male Plug Cart Part No K12.116.23.0.Pr , Fuel Return Pipe M14x1 5 Male Plug Cart Part No K12.116.24.0.Pr , Fuel Pipe From Pre Filter To Feed Pump M18x1 5 Banjo Both Siderh Side From F W Cart Part No K12.116.31.0.Pr , Bracket For Fuel Pipe Cart Part No K12.116.41.0.Pr , Control Panel Assembly For K4300 Engine Cart Part No K12.859.20.0.Pr , Star Delta Starter Panel Assembly Cart Part No K12.902.60.0.Pr , Battery Cable 1500Kva Dcc Project Cart Part No K12.903.40.0.Pr , Engine Wiring Harness Sf K4300 Engine Kg745 Unit Cart Part No K12.910.20.0.Pr , Communication Cable Harness For Dc12 Governor Cart Part No K12.910.63.0.Pr , Canopy Wiring Harness Sf K4300 Genset Cart Part No K12.911.30.0.Pr , Ct Wiring Harness From Panel To Alternator For K4300 Genset Cart Part No K12.913.30.0.Pr , K4300 Special Tools Kit Cart Part No K12.999.050.0.Sp , Contactor 25A, 4Pole, 240V Ac Cart Part No Kcl.0006.400.0.00 , Contactor 40A, 4Pole, 240V Ac Cart Part No Kcl.0018.400.0.00 , Contactor 50A, 4Pole, 240V Ac Cart Part No Kcl.0032.400.0.00 , Contactor 63A, 4Pole, 240V Ac Cart Part No Kcl.0040.400.0.00 , Contactor 80A, 4Pole, 240V Ac Cart Part No Kcl.0050.400.0.00 , Contactor 100A, 4Pole, 240V Ac Cart Part No Kcl.0065.400.0.00 , Contcactor 130A , 4 Pole, 240V Ac (Type: Kcl44 85) Cart Part No Kcl.0085.400.0.00 , Conctactor 250A 4 Pole240v Ac Koel Maketypekcl64 150 Cart Part No Kcl.0150.400.0.00 , Conctactor 320A 4 Pole240v Ac Koel Maketypekcl64 225 Cart Part No Kcl.0225.400.0.00 , Conctactor 400A 4 Pole240v Ac Koel Maketypekcl74 330 Cart Part No Kcl.0330.400.0.00 , Conctactor 630A 4 Pole240v Ac Koel Maketypekcl84 500 Cart Part No Kcl.0500.400.0.00 , Conctactor 800A 4 Pole240v Ac Koel Maketypekcl84 800 Cart Part No Kcl.0800.400.0.00 , Camshaft Bush Cart Part No Kl6.011.03.0.00 , Bearing : Main (Std) Cart Part No Kl6.011.12.0.00 , Bearing : Main 075 Cart Part No Kl6.011.15.0.00 , Thrust Washer Cart Part No Kl6.011.17.0.00 , Thrust Washer Cart Part No Kl6.011.18.0.00 , Ring: Seal A16x22 Cart Part No Kl6.011.21.0.00 , Ring Seal Cart Part No Kl6.011.23.0.00 , Ring: Seal A12x18 Cart Part No Kl6.011.25.0.00 , Cylinder Liner Cart Part No Kl6.011.30.0.00 , Nozzle: Oil Spray Cart Part No Kl6.011.31.0.00 , Nozzle: Oil Spray Cart Part No Kl6.011.32.0.00 , Bolt : Hex Cart Part No Kl6.011.33.0.00 , Gasket Cart Part No Kl6.012.02.0.00 , Gasket: Tcg Cover Cart Part No Kl6.012.08.0.00 , Oil Seal Cart Part No Kl6.012.16.0.00 , Gasket Cart Part No Kl6.013.02.0.00 , Oil Seal Cart Part No Kl6.013.08.0.00 , Sensor : Tacho 275/320 Kva Cart Part No Kl6.013.09.0.00 , Gear: Ring Starter Cart Part No Kl6.020.08.0.00 , Con Rod Assly Cart Part No Kl6.020.12.0.00 , Bolt: Collared Hex Cart Part No Kl6.020.14.0.00 , Con Rod Bush Cart Part No Kl6.020.15.0.00 , Con Rod Bearing Cart Part No Kl6.020.17.0.00 , Bearing Con Rod 0 25 Cart Part No Kl6.020.18.0.00 , Bearing Con Rod 0 75 Cart Part No Kl6.020.20.0.00 , Bearing Con Rod 1 00 Cart Part No Kl6.020.21.0.00 , Piston Cart Part No Kl6.020.22.0.00 , Piston Pin Cart Part No Kl6.020.26.0.00 , Snap Ring 45X1.75 Cart Part No Kl6.020.27.0.00 , Bolt Socket Head Cart Part No Kl6.020.30.0.00 , Piston Ring Set - 320 Kva Cart Part No Kl6.020.33.0.00 , Bush: Injection Nozzle Cart Part No Kl6.030.03.0.00 , O Ring Cart Part No Kl6.030.04.0.00 , Valve Seat Cart Part No Kl6.030.09.0.00 , Valve Seat Cart Part No Kl6.030.10.0.00 , Valve Guide Cart Part No Kl6.030.14.0.00 , Cylinder Head Assembly Rear (Modified) Cart Part No Kl6.030.15.0.00 , Gasket: Cylinder Head-Front Cart Part No Kl6.030.23.0.00 , Gasket: Cylinder Head- Rear Cart Part No Kl6.030.24.0.00 , Bolt : Collared Hex. Cart Part No Kl6.030.27.0.00 , Gasket: Cylinder Head Cover Cart Part No Kl6.030.35.0.00 , Bolt : Collared Hex. Cart Part No Kl6.030.36.0.00 , Washer Cart Part No Kl6.030.37.0.00 , Gasket: Cylinder Head Cover Cart Part No Kl6.030.38.0.00 , Housing : Breather Cart Part No Kl6.030.39.0.00 , O-Ring Cart Part No Kl6.030.40.0.00 , Valve: Inlet Altv Cart Part No Kl6.031.01.0.00 , Valve: Exhaust (Altv) Cart Part No Kl6.031.04.0.00 , Spring Valve Spring Asslyex Cart Part No Kl6.031.07.0.00 , Valve Spring (Inner) Cart Part No Kl6.031.08.0.00 , Valve Spring (Outer) Cart Part No Kl6.031.09.0.00 , Retainer : Valve Spring Cart Part No Kl6.031.12.0.00 , Valve Stem Seal Cart Part No Kl6.031.13.0.00 , Cotter : Valve Cart Part No Kl6.031.14.0.00 , Tappet: Valve Cart Part No Kl6.031.31.0.00 , Rod : Push Cart Part No Kl6.031.32.0.00 , Cam Shaft & Gear Assembly Cart Part No Kl6.031.33.0.00 , Oil Pump Assly1020 1260 Cart Part No Kl6.040.01.0.00 , Ball Brg 6006C Cart Part No Kl6.040.22.0.00 , Bolt Socket Head Cart Part No Kl6.040.26.0.00 , Head Oil Filter Cart Part No Kl6.041.03.0.00 , O-Ring Cart Part No Kl6.041.19.0.00 , Element : Oil Cooler Cart Part No Kl6.042.03.0.00 , Gasket: Oil Pipe Cart Part No Kl6.042.04.0.00 , Gasket Cart Part No Kl6.042.09.0.00 , Gasket: Oil Pipe Cart Part No Kl6.042.16.0.00 , Oil Pipe Cart Part No Kl6.042.18.0.00 , Gasket: Oil Pan Cart Part No Kl6.043.02.0.00 , Oil Level Gauge Cart Part No Kl6.043.03.0.00 , Washer Oil Pan Cart Part No Kl6.043.05.0.00 , Pipe Oil Cart Part No Kl6.043.12.0.00 , Gasket: Oil Pipe Cart Part No Kl6.043.13.0.00 , Pipe Oil Cart Part No Kl6.043.17.0.00 , Gasket : Water Pipe Cart Part No Kl6.055.04.0.00 , Gasket: Water Pipe Cart Part No Kl6.055.09.0.00 , Gasket For Cooling Water Pipe (Modified) Cart Part No Kl6.055.10.0.00 , Pipe : Cooling Water Cart Part No Kl6.055.17.0.00 , Hose: Rubber Cart Part No Kl6.055.18.0.00 , Hose Clamp: Nw 28 Cart Part No Kl6.055.19.0.00 , Hose: Rubber Cart Part No Kl6.055.20.0.00 , Pipe Cooling Water Cart Part No Kl6.055.23.0.00 , Gasket: Water Pipe Cart Part No Kl6.055.24.0.00 , Hose Rubber Cart Part No Kl6.055.25.0.00 , Hose Clamp : Nw S40 Cart Part No Kl6.055.26.0.00 , Thermostat Element Cart Part No Kl6.055.33.0.00 , Thermostat Element Cart Part No Kl6.055.34.0.00 , O-Ring Cart Part No Kl6.056.15.0.00 , Manifold Exhaust Cart Part No Kl6.081.02.0.00 , Gasket: Exhaust Mfold Cart Part No Kl6.081.06.0.00 , Bolt : Stud M10 Cart Part No Kl6.081.07.0.00 , Gasket: Intake Mfold Cart Part No Kl6.081.18.0.00 , Gasket: Cold Start Cart Part No Kl6.081.25.0.00 , Gasket Turbocharger Cart Part No Kl6.082.06.0.00 , Joint Elbow Exhaust Manifold Cart Part No Kl6.082.07.0.00 , Hose Cart Part No Kl6.082.36.0.00 , Clamp : Hose Band Type Cart Part No Kl6.082.37.0.00 , V Belt Cart Part No Kl6.083.01.0.00 , Nozzle & Holder Assly Cart Part No Kl6.100.01.0.00 , Gasket: Metal Cart Part No Kl6.100.04.0.00 , Cap: Rubber Cart Part No Kl6.100.05.0.00 , Bolt : Stud Cart Part No Kl6.100.06.0.00 , Pipe Oil Cart Part No Kl6.101.08.0.00 , Oil Pipe Cart Part No Kl6.101.12.0.00 , Fip Coupling Cart Part No Kl6.101.13.0.00 , Gasket Injection Pump Mount Cart Part No Kl6.101.31.0.00 , Hose Cart Part No Kl6.102.01.0.00 , Hose: Rubber Ring Joint Cart Part No Kl6.102.02.0.00 , Fuel Pipe Cart Part No Kl6.102.06.0.00 , Hose Cart Part No Kl6.102.09.0.00 , Clamp : Hose Ring Type Cart Part No Kl6.102.10.0.00 , Spacer Cart Part No Kl6.140.05.0.00 , Bolt : Hex. Cart Part No Kl6.140.06.0.00 , Starter Cart Part No Kl6.140.12.0.00 , Hose, Rubber C/W (Inlet) Cart Part No Kl6.175.02.0.00 , Hose Sil D75 X 80 Cart Part No Kl6.175.11.0.00 , Hose Cooling Water Cart Part No Kl6.175.12.0.00 , Rubber Hose: Thermostat To Radiator Cart Part No Kl6.175.31.0.00 , T-Bolt Hose Clamp 75-68Mm Cart Part No Kl6.175.46.0.00 , Gasket: Water Pump Cover Cart Part No Kl6.176.04.0.00 , Water Pump Assly Cart Part No Kl6.176.05.0.00 , Silencer Cart Part No Kl6.188.10.0.00 , Pipe Cac Cart Part No Kl6.190.01.0.00 , Pipe Cac Cart Part No Kl6.190.02.0.00 , Hose Fuel (Feed Pump To Filter)820Mm Cart Part No Kl6.194.04.0.00 , Hose Fuel (Filter To Fip) 660Mm Cart Part No Kl6.194.05.0.00 , Vent Pipe Radiator To Thermostat M14 X 0.5 Union Both Side Cart Part No Kl6.195.01.0.00 , Clamp Cart Part No Kl6.502.05.0.00 , Fan: 32 Plastic Cart Part No Kl6.515.01.0.00 , Fuel Pipe: 700Mm Long 7/8 Unf Union Both Side Cart Part No Kl6.516.04.0.00 , Fuel Pipe (Length 800 Mm) 7/8 Unf Union (Both Side) For K-Series Silent Set Cart Part No Kl6.528.04.0.00 , Koel Green Alternator Kg250 Stframe Mkg38 M4 Asae 1 14 415V50hz 0 8 Pf Cart Part No Kl6.801.12.0.Pr , Alternator Cart Part No Kl6.802.14.0.00 , Current Transformerset Of 3 Ct Ag3083640060rating400 625 Framekg354 Cart Part No Kl6.911.08.0.00 , Wet Pm Kit (W/O Oil) For Kl6.5001, Kl6.1045 - 6Kl12tasr1 Cart Part No Kl6.999.81.0.Sp , Mccb 75A , 3 Pole, 10Ka Breaking Capacity, Koel Make Cart Part No Kll.0075.310.0.00 , Mccb 75A , 4 Pole, 10Ka Breaking Capacity, Koel Make Cart Part No Kll.0075.410.0.00 , Mccb 100A , 3 Pole, 10Ka Breaking Capacity Cart Part No Kll.0100.310.0.00 , Mccb 100A 4 Pole10ka Breaking Capacity Cart Part No Kll.0100.410.0.00 , Mccb 125A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0125.337.0.00 , Mccb 125A 4 Pole37ka Breaking Capacity Cart Part No Kll.0125.437.0.00 , Mccb 200A , 3 Pole, 26Ka Breaking Capacity Cart Part No Kll.0200.326.0.00 , Mccb 200A , 4 Pole, 26Ka Breaking Capacity Cart Part No Kll.0200.426.0.00 , Mccb 250A , 3 Pole, 26Ka Breaking Capacity Cart Part No Kll.0250.326.0.00 , Mccb 250A , 4 Pole, 26Ka Breaking Capacity Cart Part No Kll.0250.426.0.00 , Mccb 350A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0350.337.0.00 , Mccb 350A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0350.437.0.00 , Mccb 400A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0400.337.0.00 , Mccb 400A 4 Pole37ka Breaking Capacity Cart Part No Kll.0400.437.0.00 , Mccb 500A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0500.437.0.00 , Mccb 630A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0630.337.0.00 , Mccb 630A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0630.437.0.00 , Mccb 800A , 3 Pole, 37Ka Breaking Capacity Cart Part No Kll.0800.337.0.00 , Mccb 800A , 4 Pole, 37Ka Breaking Capacity Cart Part No Kll.0800.437.0.00 , Mccb 1000A 3 Pole50ka Breaking Capacitykoel Maketypekll63 1000With Micro Cart Part No Kll.1000.350.0.00 , Mcb 6A 1 Pole06ka Breaking Capacitycurve Ckoel Maketypekml11 C6 Cart Part No Kml.0006.106.0.00 , Mcb 6A , 2 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml12 C06) Cart Part No Kml.0006.206.0.00 , Mcb 10A, 1Pole, 06Ka Breaking Capacity, Curve C Cart Part No Kml.0010.106.0.00 , Mcb 16A 1 Pole06ka Breaking Capacitycurve Ctypekml11 C16 Cart Part No Kml.0016.106.0.00 , Mcb 16A , 3 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml13 C16) Cart Part No Kml.0016.306.0.00 , Mcb 25A , 3 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml13 C25) Cart Part No Kml.0025.306.0.00 , Mcb 32A , 1 Pole, 06Ka Breaking Capacity Cart Part No Kml.0032.106.0.00 , Mcb 32A , 3 Pole, 06Ka Breaking Capacity Cart Part No Kml.0032.306.0.00 , Mcb 32A , 4 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml14 C32) Cart Part No Kml.0032.406.0.00 , Mcb 40A 2 Pole06ka Breaking Capacitycurve Ckoel Maketypekml12 C40 Cart Part No Kml.0040.206.0.00 , Mcb 40A3 Pole06ka Breaking Capacitycurve Ckoel Maketypekml13 C40 Cart Part No Kml.0040.306.0.00 , Mcb 40A 4 Pole06ka Breaking Capacitycurve Ckoel Maketype: Kml14 C40 Cart Part No Kml.0040.406.0.00 , Mcb 50A , 2 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml12c50) Cart Part No Kml.0050.206.0.00 , Mcb 50A, 3Pole, 06Ka Breaking Capacity, Curve C Cart Part No Kml.0050.306.0.00 , Mcb 50A 4 Pole06ka Breaking Capacitycurve Ckoel Maketypekml14 C50 Cart Part No Kml.0050.406.0.00 , Mcb 63A , 2 Pole, 06Ka Breaking Capacity, Curve C, Koel Make (Type: Kml12 C63) Cart Part No Kml.0063.206.0.00 , Mcb 63A 3 Pole06ka Breaking Capacity Cart Part No Kml.0063.306.0.00 , Mcb 63A 4 Pole06ka Breaking Capacity Cart Part No Kml.0063.406.0.00 , Air Filter Element Cart Part No Kt.1324.64.0.00 , Piston Ring Set -400/500/600 Kva Cart Part No Kv0.001.22.0.00 , Ring: Seal 26X31 Cart Part No Kv0.012.19.0.00 , Seal Ring A14x20 Cart Part No Kv0.012.29.0.00 , Main Bearing Cart Part No Kv0.012.30.0.00 , Thrust Bearing Cart Part No Kv0.012.31.0.00 , Cylinder Liner Cart Part No Kv0.012.33.0.00 , O Ring Upper Cart Part No Kv0.012.34.0.00 , O Ring : Lower Cart Part No Kv0.012.35.0.00 , O Ring Cart Part No Kv0.012.36.0.00 , Nozzle: Oil Spray Cart Part No Kv0.012.43.0.00 , Flange Assly Cart Part No Kv0.012.46.0.00 , Gasket Cart Part No Kv0.012.47.0.00 , Holder Oil Seal Cart Part No Kv0.012.50.0.00 , Oil Seal: Front Cart Part No Kv0.012.51.0.00 , Gasket: Seal Holder Cart Part No Kv0.012.53.0.00 , Main Bearing Cart Part No Kv0.012.56.0.00 , Gasket Cart Part No Kv0.014.16.0.00 , Gasket: Flywheel Housing Cover Cart Part No Kv0.014.22.0.00 , Seal Oilrear Cart Part No Kv0.014.24.0.00 , Sensor : Tacho Cart Part No Kv0.014.25.0.00 , Gasket: Flywheel Housing Cover Cart Part No Kv0.014.29.0.00 , O Ring Cart Part No Kv0.015.02.0.00 , Hose Cart Part No Kv0.015.03.0.00 , Rubber Hose Cart Part No Kv0.015.04.0.00 , Hose Clamp : Nw S20 Cart Part No Kv0.015.05.0.00 , Clamp : Hose Nw 12 Cart Part No Kv0.015.06.0.00 , Ring : Wear, Front Cart Part No Kv0.020.04.0.00 , Gear: Ring Starter Cart Part No Kv0.020.16.0.00 , Bolt : Collared Hex. Cart Part No Kv0.020.18.0.00 , Connecting Rod Assly Cart Part No Kv0.021.01.0.00 , Bolt: Con Rod Cart Part No Kv0.021.04.0.00 , Upper Con Rod Bearing: Std Cart Part No Kv0.021.05.0.00 , Piston Cart Part No Kv0.021.11.0.00 , Piston Pin Cart Part No Kv0.021.12.0.00 , Snap Ring Cart Part No Kv0.021.13.0.00 , Lower Bearing Conrod (Std) Cart Part No Kv0.021.21.0.00 , Lower Bearing Conrod Cart Part No Kv0.021.23.0.00 , Lower Bearing Conrod0 50 Cart Part No Kv0.021.24.0.00 , Con Rod Bush Cart Part No Kv0.021.31.0.00 , Valve Guide Cart Part No Kv0.030.04.0.00 , Seat Intake Valve Cart Part No Kv0.030.05.0.00 , Seat Exhaust Valve Cart Part No Kv0.030.06.0.00 , Cylinder Head Bolt Cart Part No Kv0.030.12.0.00 , Bolt : Cylinder Head Cart Part No Kv0.030.13.0.00 , Gasket: Cylinder Head Cart Part No Kv0.030.14.0.00 , Bolt Assly M8x45 Cart Part No Kv0.030.18.0.00 , Cap : Filler Cart Part No Kv0.030.20.0.00 , Gasket: Cylinder Head Cover Cart Part No Kv0.030.22.0.00 , Valve Guide Finish Cart Part No Kv0.030.23.0.00 , Valve: Inlet Cart Part No Kv0.031.01.0.00 , Valve: Exhaust Cart Part No Kv0.031.02.0.00 , Washer Cart Part No Kv0.031.04.0.00 , Valve Spring Assly Cart Part No Kv0.031.05.0.00 , Valve Spring (Outer) Cart Part No Kv0.031.06.0.00 , Valve Spring (Inner) Cart Part No Kv0.031.07.0.00 , Valve Spring Plate Cart Part No Kv0.031.08.0.00 , Cotter : Valve Cart Part No Kv0.031.09.0.00 , Valve Stem Seal Cart Part No Kv0.031.10.0.00 , Screw : Adjust Cart Part No Kv0.031.13.0.00 , Nut (Hex) Cart Part No Kv0.031.14.0.00 , Push Rod Cart Part No Kv0.031.20.0.00 , Oil Pump Assly Cart Part No Kv0.041.01.0.00 , Washer Spring A8 Cart Part No Kv0.041.03.0.00 , Gasket: Flange Cart Part No Kv0.041.10.0.00 , Lube Oil Filter Cartrige Cart Part No Kv0.043.03.0.00 , Gasket Oil Filter Cart Part No Kv0.043.04.0.00 , Gasket: Oil Cooler Cart Part No Kv0.044.03.0.00 , Washer: Spring A10 Cart Part No Kv0.044.07.0.00 , Bolt : Socket Head Cart Part No Kv0.044.08.0.00 , Oil Cooler Assembly Cart Part No Kv0.044.10.0.00 , Gasket: Flange Cart Part No Kv0.044.12.0.00 , Gasket Cover Housing Cart Part No Kv0.044.17.0.00 , Gasket : Oil Cooler (Old) Cart Part No Kv0.045.10.0.00 , Gasket: Flange Cart Part No Kv0.047.03.0.00 , Ring: Seal A26x32 Cart Part No Kv0.047.14.0.00 , Screw : Hollow Cart Part No Kv0.047.16.0.00 , Hose: Tc Drain Cart Part No Kv0.047.19.0.00 , Gasket: T/C Oil Return Cart Part No Kv0.047.21.0.00 , Gasket: Oil Pan Cart Part No Kv0.049.02.0.00 , Drain: Joint Assly Cart Part No Kv0.049.09.0.00 , Gasket By Pass Filter Cart Part No Kv0.049.14.0.00 , Water Pipe Gasket Cart Part No Kv0.052.03.0.00 , Hose: Sil D75 X 100 Cart Part No Kv0.052.06.0.00 , Clamp: Hose New 64 Cart Part No Kv0.052.07.0.00 , Gasket : Flange Cart Part No Kv0.052.12.0.00 , Thermostat Element Cart Part No Kv0.052.16.0.00 , O Ring: 60X4 Cart Part No Kv0.052.17.0.00 , Gasket: Thermostat Cart Part No Kv0.052.18.0.00 , Water Pump Assly Cart Part No Kv0.052.19.0.00 , Seal : Water Pump Cart Part No Kv0.052.24.0.00 , Gasket: Water Pump Cart Part No Kv0.052.32.0.00 , Pulley V Belt Cart Part No Kv0.052.35.0.00 , Hose Sil D75 X 100 Cart Part No Kv0.052.37.0.00 , Fan : Cooling Cart Part No Kv0.056.12.0.00 , Nut : Hex. M10 Cart Part No Kv0.056.18.0.00 , V Belt: Fan Pulley Ax 52 Cart Part No Kv0.056.28.0.00 , V Belt: Fan Drive 400/500/600 Kva Cart Part No Kv0.056.29.0.00 , V Belt: Water Pump 400/500/600 Kva Cart Part No Kv0.056.30.0.00 , Gasket: Exhaust Mfold Cart Part No Kv0.082.04.0.00 , Washer Cart Part No Kv0.082.06.0.00 , Exhaust Manifold Cart Part No Kv0.082.09.0.00 , Exhaust Manifold Cart Part No Kv0.082.16.0.00 , Ring: Laminated Cart Part No Kv0.082.17.0.00 , Gasket: Exhaust Mfold Cart Part No Kv0.082.18.0.00 , Bolt: Hex Cart Part No Kv0.082.19.0.00 , Spacer : Exhaust Manifold Cart Part No Kv0.082.20.0.00 , Gasket: Intake Mfold 400/500/600 Kva Cart Part No Kv0.085.02.0.00 , Gasket: Intake Mfold 400Kva Cart Part No Kv0.085.04.0.00 , Hose, Tc Inlet Cart Part No Kv0.085.10.0.00 , Rubber Hose Cart Part No Kv0.085.21.0.00 , Hose Clamp Cart Part No Kv0.085.22.0.00 , Gasket: Intercooler Cart Part No Kv0.085.33.0.00 , Turbocharger Assly Cart Part No Kv0.087.02.0.00 , Turbocharger Assly Cart Part No Kv0.087.05.0.00 , Gasket: Turbocharger Cart Part No Kv0.087.08.0.00 , Bolt : Stud Cart Part No Kv0.087.10.0.00 , Nut : Hex. M10 Cart Part No Kv0.087.12.0.00 , Nozzle & Holder Assly Cart Part No Kv0.100.01.0.00 , Nozzle Cart Part No Kv0.100.02.0.00 , Screw: Pressure Cart Part No Kv0.100.03.0.00 , Ring: Seal Cart Part No Kv0.100.04.0.00 , Seal: Nozzle Holder Cart Part No Kv0.100.05.0.00 , Screw : Hollow Cart Part No Kv0.105.06.0.00 , Piece Connection Cart Part No Kv0.105.09.0.00 , Fuel Filter Assly Cart Part No Kv0.105.12.0.00 , O Ring Cart Part No Kv0.105.25.0.00 , O Ring Cart Part No Kv0.105.26.0.00 , Priming Pump Cart Part No Kv0.105.31.0.00 , Fuel Strainer Cart Part No Kv0.105.32.0.00 , Fuel Filter Element Cart Part No Kv0.105.33.0.00 , Controller Actuator Cart Part No Kv0.105.34.0.00 , Hose: Rubber (Feed) Pump To Filter Cart Part No Kv0.108.01.0.00 , Rubber Hose: Filter To Pump Cart Part No Kv0.108.03.0.00 , Gasket Cart Part No Kv0.108.08.0.00 , Union : Banjo, Double Cart Part No Kv0.108.09.0.00 , Valve : Overflow Cart Part No Kv0.108.10.0.00 , Tube Cart Part No Kv0.108.11.0.00 , Ring: Seal A8x14 Cart Part No Kv0.108.12.0.00 , Fuel Pipe Cart Part No Kv0.108.15.0.00 , Screw : Hollow Cart Part No Kv0.108.18.0.00 , Screw : Hollow Cart Part No Kv0.108.19.0.00 , Hose Fuel For 500 And 600 Kva Cart Part No Kv0.108.34.0.00 , Hose Fuel For 500 Kva Cart Part No Kv0.108.35.0.00 , Ring : Seal A10x16 Cart Part No Kv0.109.05.0.00 , Fuel Filter Assly Cart Part No Kv0.110.01.0.00 , Fuelfilter Assembly (Glass Type 500/600 Kva) Cart Part No Kv0.110.02.0.00 , Alternator: Battery Charging Cart Part No Kv0.140.23.0.00 , Pipe : Cooling Water Cart Part No Kv0.175.08.0.00 , Starter Cart Part No Kv0.260.01.0.00 , Air Cleaner Primary Element Cart Part No Kv0.505.02.0.00 , Air Cleaner Safety Element Cart Part No Kv0.505.03.0.00 , Strap For Air Cleaner For 10K18tadia 12 Cart Part No Kv0.505.09.0.00 , Air Cleaner Assembly For 10K18ta Engine Cart Part No Kv0.505.10.0.00 , Hose T Bolt Clamp: 130Mm Od Cart Part No Kv0.505.13.0.00 , Hose Bolt Clamp: 137Mm Od Cart Part No Kv0.505.14.0.00 , Gasket : Oil Cooler (New) Cart Part No Kv2.045.10.0.00 , Gasket: Oil Pan Cart Part No Kv2.050.08.0.00 , Clamp : Hose Cart Part No Kv2.086.11.0.00 , Hose Sil D100 X 90 Cart Part No Kv2.086.21.0.00 , Hose: Rubber, Feed Pump To Filter Cart Part No Kv2.108.02.0.00 , Rubber Hose: Filter To Feed Pump Cart Part No Kv2.108.04.0.00 , Radiator Assembly (Supertropical) For 600Kva Cart Part No Kv2.189.01.0.00 , Air Cleaner Primary Element Cart Part No Kv2.505.02.0.00 , Air Cleaner Safety Element Cart Part No Kv2.505.03.0.00 , Air Cleaner Cart Part No Kv2.505.10.0.00 , Strap For Air Cleaner For 12K22tadia 14 Cart Part No Kv2.505.12.0.00 , Air Inlet Cap Cart Part No Kv2.505.13.0.00 , Hose T Bolt Clamp: 150Mm Od Cart Part No Kv2.505.14.0.00 , Air Cleaner Cart Part No Kv2.505.20.0.00 , Fuel Pre Filter Assly Cart Part No Kv2.506.20.0.00 , Water Cooled Cac For 12K22ta Heat Doublepass Cart Part No Kv2.508.01.0.00 , Stud For Balance Water Tank 370Mm Length Cart Part No Kv2.508.14.0.00 , Fuel Pipe Inlet Hose: Feed Pump To Pre Filter Cart Part No Kv2.509.01.0.00 , Fuel Pipe Return Hose 2200Mm Cart Part No Kv2.509.02.0.00 , Fuel Pipe- Suction: 12K22ta Cart Part No Kv2.509.03.0.00 , Pre Cleaner Assly Cart Part No Kv2.528.10.0.00 , Auto Vol Regulator : Avr-R450 Cart Part No Kv2.801.13.0.00 , Earthing Cable25 3850 Mm Length50 Sqmm For Altto Panel Cart Part No Kv2.901.04.0.00 , Wet Pm Kit (W/O Oil) For Kv2.5001 - 12K22ta Cart Part No Kv2.999.85.0.Sp , Lub Oil Pump Assembly Cart Part No Kv8.040.01.0.00 , Gasket Oil Pipe Cart Part No Kv8.040.10.0.00 , Oil Pipe Cart Part No Kv8.046.02.0.00 , Gasket Flange Cart Part No Kv8.046.04.0.00 , Gasket : Oil Pan Cart Part No Kv8.048.02.0.00 , Gasket Oil Pan Cart Part No Kv8.048.09.0.00 , Hose: Tc Inlet 400 Cart Part No Kv8.084.07.0.00 , Clamp Hose Cart Part No Kv8.084.15.0.00 , Clamp : Hose, Band Type Cart Part No Kv8.084.22.0.00 , Turbocharger Assly Cart Part No Kv8.087.01.0.00 , Gasket: Turbocharger Cart Part No Kv8.087.07.0.00 , Bolt : Stud Cart Part No Kv8.087.09.0.00 , Rubber Hose: Feed Pump To Filter Cart Part No Kv8.107.04.0.00 , Rubber Hose: Filter To Feed Pump Cart Part No Kv8.107.05.0.00 , Tube Cart Part No Kv8.107.12.0.00 , Fuel Pipe Cart Part No Kv8.107.15.0.00 , Hose: Engine Water Out Connect Pipe Cart Part No Kv8.175.02.0.00 , Pipe Cooling Waterradiator To Engine400kva Cart Part No Kv8.175.03.0.00 , Hose: Engine Water In Connect Pipe Cart Part No Kv8.175.04.0.00 , Hose For Balance Water Pipe Cart Part No Kv8.175.06.0.00 , Rubber Hose Cart Part No Kv8.175.12.0.00 , Air Vent Pipe Cart Part No Kv8.175.14.0.00 , Water Pump Assembly Cart Part No Kv8.182.10.0.00 , Head Oil Filtersingle Suitable For 400Kva Cart Part No Kv8.185.01.0.00 , Anti Vibration Mount Cart Part No Kv8.500.03.0.00 , Anti Vibration Mount Cart Part No Kv8.500.04.0.00 , Air Cleaner Primary Element Cart Part No Kv8.505.02.0.00 , Air Cleaner Safety Element Cart Part No Kv8.505.03.0.00 , Air Cleaner Cart Part No Kv8.505.10.0.00 , Hose T Bolt Clamp For Od 92Mm Cart Part No Kv8.505.12.0.00 , Hose T Bolt Clamp: 112Mm Od Cart Part No Kv8.505.13.0.00 , Suction Hose: 8K15ta Engine Cart Part No Kv8.505.25.0.00 , Hose T Bolt Clamp 138 Mm Id Cart Part No Kv8.505.28.0.00 , Fuel Pipe Inlet Hose: 2000Mm L Cart Part No Kv8.507.01.0.00 , Avr Model Tavr-18 Cart Part No Kv8.801.11.0.00 , Roatating Rectifier Assembly With 6 Nos. Diodes Cart Part No Kv8.801.14.0.00 , Varister Cart Part No Kv8.801.33.0.00 , 24 V Dc Relay Board 2Ch. (70 Amp.) 1C/O.Battery -Ve Signal,Din Mounted Cart Part No Kv8.853.05.0.00 , End Clamp Cart Part No Kv8.853.07.0.00 , 4 Pin Connector Cart Part No Kv8.853.14.0.00 , Adaptor1 8Npt X M10x1 5 Cart Part No Kv8.853.22.0.00 , Bush Fwe 010 Kir Tv1 Cart Part No L.019.5.10.013 , Brg.B Cart Part No L.019.5.20.003 , Brg.B Cart Part No L.019.5.20.013 , Main Bearing: 6R1080 Std Cart Part No M.006.4.00.003 , Main Brg: 6R1080 0.25 Cart Part No M.006.4.00.013 , Main Bearing: 6R1080 020 Cart Part No M.006.4.00.023 , Main Bearing 030 Cart Part No M.006.4.00.033 , Main Brg Cart Part No M.020.3.00.003 , Main Bearing: Ra3 T&B G Cart Part No M.038.4.01.003 , Main Bearing: Ra3 T&B G Cart Part No M.038.4.01.013 , Main Bearing: Ra2 T&B G Cart Part No M.038.4.01.023 , Main Bearing 030 Cart Part No M.038.4.01.033 , Main Bearing Cart Part No M.040.4.01.003 , Main Bearing 020 Cart Part No M.040.4.01.023 , Main Bearing: Sl90 Cart Part No M.055.4.00.003 , Main Bearing: Sl90 010 Cart Part No M.055.4.00.013 , Main Bearing 020 Cart Part No M.055.4.00.023 , Bearing Main Kir Sl90 Cart Part No M.055.4.00.033 , Top Two Hole Bearing Main Kir 4R810std Cart Part No M.070.4.00.003 , Main Bearing: Ha394 Cart Part No M.073.4.00.003 , Main Bearing: Ha 394 Cart Part No M.073.4.00.013 , Main Bearing: Ha394 Cart Part No M.073.4.00.023 , Main Bearing: Ha394 Cart Part No M.073.4.00.033 , Main Bearing: Ha494 Cart Part No M.074.4.00.003 , Main Bearing: Ha 494 Cart Part No M.074.4.00.013 , Main Bearing: Ha494 Cart Part No M.074.4.00.023 , Main Bearing: Ha494 Cart Part No M.074.4.00.033 , Main Bearing: Ha694 Cart Part No M.075.4.00.003 , Main Bearing: Ha694 Cart Part No M.075.4.00.013 , Main Bearing: Ha694 020 Cart Part No M.075.4.00.023 , Main Bearing: Ha294 Cart Part No M.093.4.00.003 , Main Bearing 010 Cart Part No M.093.4.00.013 , Main Bearing 020 Cart Part No M.093.4.00.023 , Main Bearing 030 Cart Part No M.093.4.00.033 , Main Bearing: Dv10 Std Cart Part No M.547.4.00.003 , Main Bearing: 4R810 Std Cart Part No M.552.4.00.003 , Main Bearing: 6K1080ta Std Cart Part No M.553.4.00.003 , Main Bearing: 4K1080 Std Cart Part No M.553.4.10.003 , Bearing Main Kir 6K1080eta Crdi, Std Cart Part No M.554.4.00.003 , Valve Collet Cart Part No N11.008.13.0.00 , Bearing 6305 Zz - 62 Mm Cart Part No N11.029.65.0.00 , Flanged Screw - M6 X 1.0 X 10 Cart Part No N11.051.01.0.00 , Flanged Nut M6 X 1.0 Cart Part No N11.051.02.0.00 , Flanged Nut - M8 X 1.25 Cart Part No N11.051.05.0.00 , Flanged Screw - M6 X 1.0 X 12 Mm Cart Part No N11.051.06.0.00 , Humidity Sensor Bolt M10x80 Hex Bolt (Ss) (Hhb1080-Ss) Cart Part No Owc.Mmf.125.02.Sp , Gas Spring Size=12 Capacity=10 Kg (Bgs1210) Cart Part No Owc.Mmf.125.16.Sp , Bacteria Soil For 125 Kg I Land Machine60kg Cart Part No Owc.Mmf.125.26.Sp , Humidity Sensor Plate 100X50x12 (Sp-70) Cart Part No Owc.Mmf.25.05.Sp , Humidity Sensor Bush ?19X18 (Sp-70) Cart Part No Owc.Mmf.25.06.Sp , Humidity Sensor Washer ?19X4.5 (Sp-70) Cart Part No Owc.Mmf.25.07.Sp , Humidity Electronics Box (Ehb001) Cart Part No Owc.Mmf.25.16.Sp , Temperature Sensor Pt 100 Outside Tank 6 Mm Ring Type (Pt100); 3 Mtr (Etso0603100) Cart Part No Owc.Mmf.25.18.Sp , Temperature Sensor Pt 100 Inside Tank 6 Mm X 25 Mm (Pt100)¼ Bsp; 3 Mtr (Etsi0603100) Cart Part No Owc.Mmf.25.19.Sp , Oil Seal 40X52x7 Adl (Rubber Od Double Lip With Garter Spring) (Bos04007) Cart Part No Owc.Mmf.25.21.Sp , Gas Spring Size=9 Capacity=5 Kg (Bgs0905) Cart Part No Owc.Mmf.25.30.Sp , Bacteria Soil For 25 Kg I Land Machine12kg Cart Part No Owc.Mmf.25.44.Sp , Oil Seal 80X100x8 Adl (Rubber Od Double Lip With Garter Spring) (Bos08008) Cart Part No Owc.Mmf.250.06.Sp , Gas Spring 15 Kg (Gs) Cart Part No Owc.Mmf.250.15.Sp , Ceramic Heater 1500 W35 X5 415 Vacech15003505 Cart Part No Owc.Mmf.250.25.Sp , Oil Seal 90X110x10 Adl (Rubber Od Double Lip With Garter Spring) (Bos09010) Cart Part No Owc.Mmf.250.27.Sp , Compost Door Hinge Flat Hinge Dhim 10080Bfh10080 Cart Part No Owc.Mmf.500.03.Sp , Bacteria Soil For 500 Kg I Land Machine350kg Cart Part No Owc.Mmf.500.18.Sp , Gas Spring 10Kg (Bgs1210) Cart Part No Owc.Mmf.75.04.Sp , Blower Motor 300 Cfm, 90 W, 230 Vac (Ebm300090) Cart Part No Owc.Mmf.75.19.Sp , Ceramic Heater 500 Watts, 415 Vac, 24 X 3 (Ech5002403) Cart Part No Owc.Mmf.75.20.Sp , Bacteria Soil For 75 Kg I Land Machine35kg Cart Part No Owc.Mmf.75.23.Sp , Main Motor For Gear Drive, Rating 0.37 Kw, 0.5Hp, 415 Vac, Ki-75 Cart Part No Owc.Mmf.75.45.Sp , Helical Gearbox For Ki-75 Cart Part No Owc.Mmf.75.46.Sp , Bearing 6202 Llu Cart Part No P03.0901.203.0.00 , Bush Bearing Cart Part No P08.0001.012.0.00 , Gasket: Cylinder Head 2Cyl 1.22 Thk Cart Part No P1.007.09.0.00 , High Pressure Pipe Assembly Cart Part No P1.011.10.0.00 , Exhaust Manifold Cart Part No P1.036.01.0.00 , Ball Bearing 6202 Zz Exclusively For Power Tiller Cart Part No P15.0516.011.0.Pr , Gallary Plug Cart Part No P2.001.02.0.00 , Camshaft Assly Cart Part No P2.003.10.0.00 , Lub Oil Pump Assly Cart Part No P2.005.10.0.00 , Valve Seat Insert: Exhaust Cart Part No P2.007.03.9.00 , Exhaust Valve (Chrome Plated) Cart Part No P2.007.06.0.00 , Valve Pair For 3R860 Cart Part No P2.007.40.0.00 , Belt Xpa 1232 Cart Part No P2.015.04.0.00 , Deflector For Oil Seal Cart Part No P2.020.09.0.00 , O Ring Cart Part No P2.021.03.0.00 , Water Pump Assly With Pulley Cart Part No P2.021.10.0.00 , Exhaust Manifold Cart Part No P2.036.01.0.00 , Cover Plate Cart Part No P2.038.17.0.00 , Cap Assembly Cart Part No P2.039.07.0.00 , Gear Casing For 4Wd Cart Part No P2.045.01.0.00 , Drive Shaft Assly. Cart Part No P2.049.20.0.00 , Water Pump Assly Cart Part No P2.051.10.0.00 , Thermostat Housing Cart Part No P2.066.30.0.00 , Joint Cart Part No P2.075.03.0.00 , High Pressure Pipe Assembly Cart Part No P2.093.50.0.00 , Crankcase W/O Bearings Cart Part No P2.100.10.0.00 , Monoblock Crankcaseline Bearing Operation Cart Part No P2.100.40.0.00 , Gear Casing For 3R860 Wr Cart Part No P2.101.01.0.00 , Joint: Gear Casing 3R860 Wr Cart Part No P2.101.02.0.00 , S.S. Joint For Exhaust Manifold Cart Part No P2.106.01.0.00 , Fuel Pipe Feed To Filter Cart Part No P2.114.01.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No P2.114.02.0.00 , Adaptor (For Spin-On Type Filter) Cart Part No P2.118.02.0.00 , Joint: Fuel Pump Gear Cover Cart Part No P2.121.03.0.00 , Crank Shaft Pulley Cart Part No P2.124.01.0.00 , Leak Off Pipe Cart Part No P2.127.10.0.00 , Valve Rocker Assembly Cart Part No P3.010.10.0.00 , Lube Oil Cooler Cart Part No P4.041.01.0.00 , Water Pipe (From Crankcase To Oil Cooler) Cart Part No P4.041.02.0.00 , Water Pipe (From Oil Cooler To Crankcase) Cart Part No P4.041.03.0.00 , Crankshaft Assly.With Cr.Gear Cart Part No P5.005.20.0.00 , Lifting Hook Cart Part No P5.013.02.0.00 , Oil Filling Body Cart Part No P5.014.01.0.00 , Jont For Exhaust Manifold (Non Asbestos) Cart Part No P5.036.02.0.00 , Breather Pipe Cart Part No P5.041.01.0.00 , Tension Adjusting Lever Cart Part No P5.046.01.0.00 , Spacer Bolt Cart Part No P5.046.03.0.00 , Alternetor Mtg Bkt Cart Part No P5.046.04.0.00 , Flywheel Housing (S/F Ace Tractor) Cart Part No P5.075.02.0.00 , Lub. Oil Sump Cart Part No P5.076.01.0.00 , Dipstick Assly Cart Part No P5.078.10.0.00 , Belt Spax 1220 Cart Part No P5.079.01.0.00 , Brg Bush S/E: 6R1080 Eng Se Cart Part No S.006.5.00.703 , Bearing Bush Cart Part No S.034.5.00.703 , Small End Bush Cart Part No S.038.5.01.003 , Bearing Bush S/E: Ra3 Cart Part No S.038.5.01.703 , Bearing Small End Bush Cart Part No S.051.5.00.003 , Bearing Bush S/E: Rbv3 Cart Part No S.051.5.00.703 , Bearing Bush S/E: Rbv4 Cart Part No S.052.5.00.703 , Bearing Bush S/E: Sl90 Cart Part No S.055.5.00.703 , Bearing Bush S E Kir Sl90250kvastd Ub Cart Part No S.055.5.20.703 , Bush Bearing S/E: Ha394 Cart Part No S.073.5.00.003 , Bush Bearing S/E: Ha394 Cart Part No S.073.5.00.703 , Bearing Bush S/E: Ha494 Cart Part No S.074.5.00.003 , Bearing Bush S/E Kir Ha 494 Cart Part No S.074.5.00.703 , Bearing Bush S/E: Ha694 Cart Part No S.075.5.00.003 , Bearing Bush S/E Kir Ha 694 Cart Part No S.075.5.00.703 , Bearing Bush S/E: Ha294 Cart Part No S.093.5.00.003 , Bush Bearing S/E: Ha294 Cart Part No S.093.5.00.703 , Bearing C R Bush Kir Dv10std Ub Cart Part No S.547.5.00.703 , Small End Bush Cart Part No S.547.5.10.703 , Bearing Bush S/E: 4R810 Std Ub Cart Part No S.552.5.00.703 , Bearing Bush S/E: 6K1080ta Std Cart Part No S.553.5.00.703 , Bearing Small End Bush Cart Part No S.553.5.10.703 , Contactor Spare Coil For 25 40 A 240 Vac For Frame 1 Koel Make Cart Part No Scl.0001.240.0.00 , Contactor Spare Coil For 50 63 A 240 Vac For Frame 2 Koel Make Cart Part No Scl.0002.240.0.00 , Contactor Spare Coil For 80 130 A 240 Vac For Frame 3 And 4 Koel Make Cart Part No Scl.0034.240.0.00 , Contactor Spare Coil For 400A 240 Vac For Frame 7 2 Koel Make Cart Part No Scl.0072.240.0.00 , Dowel Dia 18 (Fwe) Cart Part No T1.001.12.0.00 , Bush For Crankcase (Oil Metering) Cart Part No T1.001.16.0.00 , O Ring: Cylinder Liner- Viton Cart Part No T1.002.04.0.00 , Crankshaft Gear Cart Part No T1.003.03.0.00 , Con Rod Bolt Cart Part No T1.004.03.0.00 , Camshaft Gear Cart Part No T1.006.02.0.00 , Thrust Plate Cart Part No T1.006.03.0.00 , Sub Assly Of Camshaft Cart Part No T1.006.10.0.00 , Lub Oil Pump Assembly Cart Part No T1.007.10.0.00 , Bracket: Suction Tube Cart Part No T1.008.03.0.00 , Joint: Suction Tube Cart Part No T1.008.05.0.00 , Delivery Tube Cart Part No T1.009.01.0.00 , Gear Support Cart Part No T1.010.03.0.00 , Retaining Plate Intermediate Gear Cart Part No T1.010.04.0.00 , Assembly Of Intermediate Gear Cart Part No T1.010.10.0.00 , Fuel Pump Gear Cart Part No T1.011.01.0.00 , Hub For Fuel Pump Fear Cart Part No T1.011.03.0.00 , Gear Casing Cart Part No T1.013.01.0.00 , Joint: Gear Cover Cart Part No T1.013.02.0.00 , Valve Guide Finish Cart Part No T1.016.02.0.00 , Valve Guide (Semi-Finish) Cart Part No T1.016.02.9.00 , Cylinder Head Bolt Cart Part No T1.016.07.0.00 , Joint: Water Pump Cart Part No T1.017.02.0.00 , Water Pump Assly Cart Part No T1.017.30.0.00 , Water Pump Assembly-For Crane Cart Part No T1.017.50.0.00 , Starter Ring Cart Part No T1.019.03.0.00 , Push Rod Cart Part No T1.020.01.0.00 , Injector Cart Part No T1.023.28.0.00 , Joint: Rocker Cover Cart Part No T1.024.02.0.00 , Joint: Inlet Mfold Cart Part No T1.025.02.0.00 , Gasket: Exhaust Mfold Cart Part No T1.026.02.0.00 , Spacer (Id 8.5 X Od 13 X 29 L) Cart Part No T1.026.03.0.00 , Copper Coated Allen Bolt- 50.011.08.050 Cart Part No T1.026.04.0.00 , Cover For Fuel Pump Bore Cart Part No T1.035.01.0.00 , Header For Spin On Type Filter Cart Part No T1.036.01.0.00 , Joint: Lube Oil Header Cart Part No T1.036.02.0.00 , Joint For Thermostat Housing Cart Part No T1.037.02.0.00 , Dipstick Assly Cart Part No T1.039.10.0.00 , Dipstick Assembly Cart Part No T1.039.20.0.00 , Joint: Braether Housing Cart Part No T1.040.07.0.00 , Brather Box Assembly Cart Part No T1.040.30.0.00 , Leak Off Pipe Assembly Cart Part No T1.047.30.0.00 , Piston Pin Cart Part No T1.050.02.0.00 , Piston Ring Set Cart Part No T1.050.10.0.00 , Piston Assembly Cart Part No T1.050.20.0.00 , Piston Assembly Cart Part No T1.050.90.0.Sp , Valve Seat Insert: Inlet Cart Part No T1.057.02.9.00 , Valve Seat Insert: Exhaust Cart Part No T1.057.03.9.00 , Valve Pair Cart Part No T1.057.90.0.00 , Cyl Liner Assembly Cart Part No T1.058.10.0.00 , Cylinder Liner Assly Cart Part No T1.058.20.0.00 , Cylinder Liner Assembly With O Ringmls Gasket Cart Part No T1.058.30.0.00 , Cranksahft Assembly Cart Part No T1.074.20.0.00 , Crank Pulley (Eicher) Cart Part No T1.077.01.0.00 , Exhaust Manifold Cart Part No T1.091.01.0.00 , Joint For Adaptor (Hydraulic Pump) Cart Part No T1.098.03.0.00 , Fuel Pipes Fuel Filter To Fip Cart Part No T3.007.01.0.00 , Fuel Pipes Feed Pump To Fuel Filter Cart Part No T3.007.02.0.00 , Cylinder Head Gasket1 22 Mmthick Cart Part No T3.009.03.0.Pr , Sub Asm. Of Cam Shaft Cart Part No T4.003.10.0.00 , Suction Tube Cart Part No T4.004.10.0.00 , Inlet Manifold (Ge Side Top Opening) Cart Part No T4.009.14.0.00 , Inlet Manifold (Cold Side) Cart Part No T4.009.15.0.00 , High Pressure Pipe Assembly Cart Part No T4.013.20.0.00 , High Pressure Pipe Assembly Cart Part No T4.013.220.0.00 , High Pressure Pipe Assembly Cart Part No T4.013.30.0.00 , Rocker Cover Cart Part No T4.015.01.0.00 , Joint: Rocker Cover Cart Part No T4.015.02.0.00 , Joint For Rocker Cover Cart Part No T4.015.05.0.00 , 500 Hrs - B Check Maintenance Kit Cart Part No T4.019.013.0.Sp , Fuel Filter Bracket Cart Part No T4.019.03.0.00 , 1500 Hrs - C Check Maintenance Kit Cart Part No T4.019.15.0.Sp , Air Inlet Manifold, Jcb Cart Part No T4.020.01.0.00 , Driven Hub For Compressor Cart Part No T4.021.02.0.00 , Spider Coupling Cart Part No T4.021.03.0.00 , Driving Hub For Compressor Cart Part No T4.021.04.0.00 , Deep Groove Ball Bearing Cart Part No T4.021.05.0.00 , Gear For Compressor Cart Part No T4.021.06.0.00 , Joint: Compressor Housing To Crankcase Cart Part No T4.021.07.0.00 , Joint: Compressor Cart Part No T4.021.08.0.00 , Cover Plate For Compressor Bore On Crankcase Cart Part No T4.021.09.0.00 , Exhaust Manifold Ge Top Open Cart Part No T4.022.02.0.00 , Bolt Copper Coated 50 002 08 110 Cart Part No T4.022.04.0.00 , Compressor Lub Oil Drain Pipe, Modified Cart Part No T4.024.05.0.00 , Crank Pulley Pcd 1556 Cart Part No T4.027.01.0.00 , Crank Shaft Pulley (137.5 Pcd) Cart Part No T4.027.04.0.00 , Crank Pulley For137 5 Pcdt4 027 09 0 00 Cart Part No T4.027.09.0.00 , Alternator Pulley (Pcd 565 4Pk) Cart Part No T4.027.17.0.00 , Crankshaft Pulley (137.5 Pcd) Cart Part No T4.027.18.0.00 , Crankshaft Puley Pcd135 3 5Pk Poly V Groove Cart Part No T4.027.21.0.Pr , Alternator Tensioning Lever Cart Part No T4.028.01.0.00 , V Belt: Spax 1180 Cogged Cart Part No T4.029.01.0.00 , V Belt: Spax1160 Cogged Cart Part No T4.029.03.0.00 , Cylinder Head Bolt Cart Part No T4.030.05.0.00 , Cyl Head Gaskt With Fire Ring 1.37Mm Cart Part No T4.030.08.0.00 , Gasket: Cylinder Head 1.32 Thk Cart Part No T4.030.09.0.00 , Cylinder Head Assembly Cart Part No T4.030.50.0.00 , Joint: Thermostat Cover Cart Part No T4.031.02.0.00 , Hose (Thermostat Hsg To Water Pump) Cart Part No T4.031.04.0.00 , Thermostat Housing Assmebly M14 Both Sides With Adaptor Cart Part No T4.031.110.0.Pr , Thermostat Housing Assembly Cart Part No T4.031.40.0.00 , Thermostat And Housing Cart Part No T4.031.60.0.00 , Thermostat Housing Assembly (M14 And 0.5 Nptf) Cover Toward Fan Cart Part No T4.031.90.0.00 , Oil Seal Housing Cart Part No T4.033.01.0.00 , Oil Seal Cart Part No T4.033.02.0.00 , Rocker Cover Cast-Iron (Machining) Cart Part No T4.036.01.0.00 , Inlet Adaptor ( On Inlet Manifold) S/F Ecel Cart Part No T4.043.01.0.00 , Breather Hose Cart Part No T4.053.01.0.00 , Hose For Breather (Connecting To Baseplate) Cart Part No T4.053.05.0.00 , Hose For Breather: Connecting To Base Plate Cart Part No T4.053.07.0.00 , Hose For Breather; Connecting To Bend Pipe Cart Part No T4.053.08.0.00 , Leak Off Pipe Assly Cart Part No T4.053.10.0.00 , Hose (Radiator To Pump Inlet Pipe) Cart Part No T4.053.15.0.00 , Hose (For Radiator To Water Inlet Pipe) Cart Part No T4.053.16.0.00 , Pipe (Radiator To Pump Inlet) Cart Part No T4.053.17.0.00 , Hose: Air Cleaner Cart Part No T4.053.18.0.00 , Leak Off Pipe Cart Part No T4.053.21.0.00 , Fuel Pipe Mud Filter To Fip Cart Part No T4.053.24.0.00 , Leak Off Pipe (Injector) (Polyamide) Cart Part No T4.053.38.0.00 , Hose For Radiator To Water Inlet Pipe Cart Part No T4.053.49.0.Pr , Hose Radiator To Pump Inlet Cart Part No T4.053.54.0.00 , Hose In Between Air Cleaner And Turbo Cart Part No T4.053.56.0.Pr , Hose Radiator To Pump Inlet Pipe Cart Part No T4.053.93.0.Pr , Lub Oil Sump Cast-Iron (Rear) Machining Cart Part No T4.054.01.0.00 , Lube Oil Sump Cart Part No T4.054.02.0.00 , Lube Oil Sump Cart Part No T4.054.10.0.00 , Hose For Air Cleaner Cart Part No T4.058.01.0.00 , Lub Oil Pump Assembly Cart Part No T4.067.105.0.Pr , Lube Oil Pump Cart Part No T4.067.55.0.00 , Lub Oil Pump Assly Cart Part No T4.067.75.0.Pr , Lube Oil Pump Cart Part No T4.067.90.0.00 , Oil Supply Pipe Cart Part No T4.070.02.0.00 , Flywheel Assembly Sf Bull India Cart Part No T4.075.10.0.00 , Flywheel And Starter Ring Assembly Cart Part No T4.075.35.0.Pr , Flywheel And Starter Ring Assembly Cart Part No T4.075.70.0.00 , Flywheel Housing Cart Part No T4.076.01.0.00 , Flywheel Housing For Pg Sae3 Cart Part No T4.076.02.0.00 , Flywheel Housing Sae-3 Cart Part No T4.076.06.0.Pr , Engine Mtg. Foot ( Alt Side ) Cart Part No T4.077.01.0.00 , Engine Mtg. Foot ( Starter Side ) Cart Part No T4.077.02.0.00 , Set Of Joints Cart Part No T4.087.10.0.Sp , Set Of O Rings Cart Part No T4.087.20.0.00 , Set Of Copper Washer Cart Part No T4.087.30.0.00 , Engine Mtg Foot (Ge Lh) Cart Part No T4.088.01.0.00 , Engine Mtg Foot (Ge Rh) Cart Part No T4.088.02.0.00 , Crankcase With Bearing Caps Cart Part No T4.090.60.0.Sp , Fan (Pusher Type-Metallic 22 Dia Mtg Hole-55 Pcd) Cart Part No T4.101.43.0.00 , Radiator Cart Part No T4.103.10.0.00 , Cac Core Assembly For T4 103 10 0 00 Aluminium Radiator Assembly Cart Part No T4.103.26.0.Sp , Aluminium Radiator Assembly Cart Part No T4.103.40.0.Pr , Lever For Charging Alternator Cart Part No T4.104.14.0.00 , Engine Wiring Harness For 4Rta Crdi Cpcb4 Cart Part No T4.1043.10.0.Pr , Engine Control Panel To Alternator Avr Harness For Optiprime (57X2 Kva) Cart Part No T4.1043.40.0.Pr , Engine Wiring Harness For 4Rta Crdi Engine B For Optiprime (2X57kva) Cpcb4+ Cart Part No T4.1043.60.0.Pr , Engine Wiring Harness For 4Rta Crdi Engine A For Optiprime (2X57kva) Cpcb4+ Cart Part No T4.1043.70.0.Pr , Canopy Wiring Harness For 4R Cpcb4 Cart Part No T4.1044.10.0.Pr , Canopy Wiring Harness For Optiprime (57X2 Kva) 4R Cpcb4+ Cart Part No T4.1044.20.0.Pr , Control & Power Panel Assembly For 57 Kva 3Ph Cpcb 4 Cart Part No T4.1045.10.0.Pr , Hose For Air Cleaner Cart Part No T4.106.05.0.00 , Hose For Air Cleaner To Inlet Manifold 70 Id 90 Deg Cart Part No T4.106.07.0.Pr , Bracket For Alternator Cart Part No T4.107.01.0.00 , Tensioning Lever For Belt Cart Part No T4.107.02.0.00 , Bracket For Alternator Cart Part No T4.107.03.0.00 , Bracket For Alternator Mounting Cart Part No T4.107.06.0.00 , Bracket For Alternator Mounting Cart Part No T4.107.08.0.00 , Eye Bolt For Alternator Cart Part No T4.107.11.0.00 , Eye Bolt For Alternator Cart Part No T4.107.18.0.Pr , Bracketfor Stretch Belt Arrangement Cart Part No T4.107.19.0.Pr , Bracket For Alternator Cart Part No T4.107.21.0.00 , Bracket For Fuel Filter & A/C Mtg. Cart Part No T4.108.07.0.00 , Engine Mounting Foot Ge (Alt Side) Cart Part No T4.115.01.0.00 , Engine Mounting Foot Ge (Fip Side) Cart Part No T4.115.02.0.00 , Header For Lube Oil Cooler & Filter Cart Part No T4.116.06.0.00 , Joint: Lube Oil Header Cart Part No T4.116.07.0.00 , Header For Lub Oil Cooler & Filter (Finish) (Suitable For 8 Plate Cooler) Cart Part No T4.116.09.0.00 , Joint For Lub Oil Cooler Cart Part No T4.116.12.0.00 , Joint: Air Pipe Tc To Air Inlet Manifold Cart Part No T4.117.03.0.00 , Air Pipe Tc To Air Inlet Manifold Cart Part No T4.117.16.0.00 , Jointfor Cac Pipe Cart Part No T4.117.17.0.00 , Hose (215 Id X 32 Od, 50 Long) Cart Part No T4.118.03.0.00 , Lube Oil Supply Pipe For Turbo Cart Part No T4.118.38.0.00 , Drain Pipe Assembly For Turbocharger Cart Part No T4.118.39.0.00 , Lube Oil Supply Pipe Cart Part No T4.118.40.0.00 , Joint For Turbo Drain Pipe Cart Part No T4.118.41.0.00 , Turbo Lube Oil Supply Piping Assembly Cart Part No T4.118.45.0.00 , Jointbetturbo Adaptor Crankcase Cart Part No T4.118.46.0.Pr , Drain Pipe Assembly Cart Part No T4.118.50.0.00 , Piston Cooling Nozzle Cart Part No T4.119.02.0.00 , Adaptor (M16 To M12) For Turbo Oil Inlet Cart Part No T4.119.11.0.00 , Adaptor (M12 X 175 To M16 X 15)For Turbo Oil Inlet Cart Part No T4.119.12.0.00 , Crank Case With Brgcaps Cart Part No T4.119.30.0.Sp , Gear Cover Cart Part No T4.121.01.0.00 , Joint: Turbo & Exhaust Manifold Cart Part No T4.122.12.0.00 , Joint: Turbo & Diffuser Cart Part No T4.122.13.0.00 , Joint: Turbo & Exhaust Diffuser Cart Part No T4.122.14.0.00 , Joint: Exhaust Manifold & Turbo Cart Part No T4.122.18.0.00 , Exhaust Manifold Cart Part No T4.122.21.0.00 , Exhaust Manifold Cart Part No T4.122.22.0.00 , Exhaust Manifold Cart Part No T4.122.23.0.00 , Socket Head Bolt (M8x50) Cart Part No T4.122.24.0.00 , Stud M8 X 35 Cart Part No T4.122.25.0.00 , Stud (M10x60) Cart Part No T4.122.27.0.00 , Studm12 X 65 Cart Part No T4.122.28.0.00 , Stud (M10 X 70) Cart Part No T4.122.29.0.00 , Stud (M8 X 25) Cart Part No T4.122.31.0.00 , Stud (M10 X 25) Cart Part No T4.122.32.0.00 , Stud (M10 X 30) Cart Part No T4.122.33.0.00 , Socket Head Bolt (M8x22) Cart Part No T4.122.34.0.00 , Stud (M8 X 20) Cart Part No T4.122.35.0.00 , Set Screw (M8x25) Cart Part No T4.122.36.0.00 , Nut - M8x1.25 - Gr.10 Cart Part No T4.122.39.0.00 , Nut - M10x1.5 - Grade 10 Cart Part No T4.122.41.0.00 , Nut M12x1 75 Grade 10 Cart Part No T4.122.42.0.00 , Stud M10x40lfor High Temp Cart Part No T4.122.48.0.00 , Studm10x55 Cart Part No T4.122.49.0.00 , Stud (M8 X 30) 10.9 Grade Cart Part No T4.122.51.0.00 , Set Screwm8x1610 Grade Cart Part No T4.122.52.0.00 , Stud (M10 X 30) Cart Part No T4.122.59.0.00 , Exhaust Manifold With Hr Paint 4R810t Project Bsiiibackhoe Cart Part No T4.122.63.0.Pr , Turbocharger Cart Part No T4.125.03.0.00 , Turbocharger For 4R810 Enginetel No Cart Part No T4.125.07.0.Pr , Gasket Lube Oil Pump & Suction Tube Cart Part No T4.126.07.0.00 , Clamp Strap Rh Suction Tube Cart Part No T4.126.08.0.00 , Clamp Strap Lh (4R810t Suction Tube) Cart Part No T4.126.09.0.00 , Suction Tube Cart Part No T4.126.12.0.Pr , Gasketfor Suction Tube Cart Part No T4.126.14.0.Pr , Suction Tube Cart Part No T4.126.30.0.00 , Camshaft Sub Assly Cart Part No T4.128.20.0.00 , Cam Shaft & Gear Assembly Cart Part No T4.128.40.0.00 , Suction Pipe (Water Pump) Cart Part No T4.130.01.0.00 , Joint: Suction Pipe & Gear Cover Cart Part No T4.130.02.0.00 , Suction Pipe For Water Pump Cart Part No T4.130.03.0.00 , Hose Pipe Cart Part No T4.130.04.0.00 , Joint: Water Pump & Gear Cover Cart Part No T4.131.01.0.00 , Water Pump Pulley-110 Pcd Spa Section Cart Part No T4.131.02.0.00 , Water Pump Assly Cart Part No T4.131.10.0.00 , Fan Spacer70 Mm Cart Part No T4.131.11.0.00 , Water Pump Pulley Spa Section (110 Pcd) (55 Mtg Pcd) Cart Part No T4.131.26.0.Pr , Water Pump Pulley 4Pk Section94 6 Pcd 55 Mtg Pcd Cart Part No T4.131.27.0.Pr , Water Pump Pulley 5Pk Section94 6 Pcd 55 Mtg Pcd Cart Part No T4.131.28.0.Pr , Fan Spacer- 70Mm Cart Part No T4.131.43.0.00 , Water Pump Assemblywith Impeller And Seal Cart Part No T4.131.75.0.Pr , Thermostat & Housing Cart Part No T4.132.50.0.00 , Thermostat & Housing Assembly (M14 Tapping Both Sides) With Core Plug On Lhs Cart Part No T4.132.80.0.00 , 4Pkepdm Poly- V Belt Cart Part No T4.134.05.0.Pr , Delivery Tube Cart Part No T4.136.01.0.00 , Flywheel Assembly Cart Part No T4.138.20.0.00 , Nozzle Leak Off Pipe Assly Cart Part No T4.140.15.0.00 , Nozzle Leak Off Pipe Assly Cart Part No T4.140.25.0.Pr , Rotary Fip: 4R810t 60Hp @ 2400 Rpm Cart Part No T4.143.05.0.00 , Fip: 4R810 Ta 83 Hp@1500Rpm Cpcbii Cart Part No T4.143.07.0.00 , High Pressure Pipe Assembly Cart Part No T4.152.40.0.00 , Assembly Of Intermediate Gear Cart Part No T4.153.10.0.00 , Flywheel Cart Part No T4.155.20.0.00 , Gear (For Hydraulic Pump) Cart Part No T4.158.02.0.00 , Crankshaft Assembly Cart Part No T4.159.30.0.00 , Crankshaft Assembly Cart Part No T4.159.50.0.00 , Con Rod Assly Cart Part No T4.160.30.0.00 , Connecting Rod Assemblyfractured Cart Part No T4.160.40.0.Pr , Fan: 17/5-5/40/Pag/1Zl Cart Part No T4.161.01.0.00 , Spacer 68 Mm Width For Mounting Fan 17/5-5/40?/Pag/1Zl Cart Part No T4.161.03.0.00 , Fan Assembly 17 5 5 40Pag 1Zl Cart Part No T4.161.20.0.00 , Flywheel Housing Sae 3183 Mm Width Cart Part No T4.163.01.0.00 , Adaptor On Flywheel Cart Part No T4.164.02.0.00 , Alternator Bracket Cart Part No T4.165.01.0.00 , Belt Guard Cart Part No T4.166.03.0.00 , Belt Guard Cart Part No T4.166.21.0.00 , Belt Guard For Stretch Belt Cart Part No T4.166.27.0.Pr , Piston Assembly: R810t/Ta Bsiii Cart Part No T4.170.10.0.00 , Piston Ring Set Cart Part No T4.170.20.0.00 , Hose Air Cleaner Bs Iii Cart Part No T4.171.02.0.00 , Bracket For Spinon Filter Mounting Cart Part No T4.174.01.0.00 , Hub With Facial Cam Cart Part No T4.181.03.0.00 , Fuel Pump Gear Cart Part No T4.181.04.0.00 , Cover For Fuel Pump Gear Cart Part No T4.182.01.0.00 , Cover Plate (Aluminium) For Fuel Pump Gear (Finish) (4R810t With Inline Fuel Pump) Cart Part No T4.182.03.0.00 , Gear Casing Cart Part No T4.183.05.0.00 , Fuel Injection Pump For 4R810na Engine Cart Part No T4.185.02.0.00 , Fip: 4R810na49.5Hp @ 2200Rpm Hd Governor Cart Part No T4.185.03.0.00 , Turbocharger For 3R1190ta Cpcb Iv+ Cart Part No T4.187.30.0.Pr , Hose: Air Cleaner Cart Part No T4.191.05.0.00 , Hose For Pvc Pipe Cart Part No T4.191.16.0.00 , Bracket For Air Cleaner Mounting Cart Part No T4.191.19.0.Pr , Fuel Pipe 200 L Cart Part No T4.193.01.0.00 , Exhaust Silencer Assembly For 60 Hp @ 2400 Rpm Bs Iii Engine Cart Part No T4.196.01.0.00 , Exhaust Diffuser Bull Cart Part No T4.197.01.0.00 , Bracket For Exhaust Diffuser Mounting -Bull (Bs Iii) Cart Part No T4.197.02.0.00 , Hose For Aircleaner Cart Part No T4.198.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No T4.201.01.0.00 , Fuel Pipe Feed Pump To Fuel Filter Cart Part No T4.201.02.0.00 , Fuel Pipe Fuel Filter To Fip Cart Part No T4.201.05.0.00 , Fuel Pipe (Feed Pump To Fuel Filter ) Cart Part No T4.201.06.0.00 , Fuel Pipe (Fuel Filter To Pump) (Polyamide) Cart Part No T4.201.16.0.00 , Fuel Pipe(Feed Pump To Fuel Filter ) (Polyamide) Cart Part No T4.201.17.0.00 , Piston Ring Set For 4R810ta Cart Part No T4.202.20.0.Pr , Crankcase Assly Cart Part No T4.203.100.0.00 , Exhaust Diffuser Cart Part No T4.206.11.0.00 , Joint: Turbo & Exhaust Diffuser Cart Part No T4.206.13.0.00 , Bracket For Fuelpipes Cart Part No T4.206.18.0.00 , Joint Cart Part No T4.206.23.0.Pr , Cac Pipe Cart Part No T4.207.07.0.00 , Cac Hose Cart Part No T4.207.08.0.00 , Air Pipe (Turbo To Radiator) Cart Part No T4.207.09.0.00 , Cac Hose (Hot Side 4 Plies) Cart Part No T4.207.12.0.00 , Cac Hose Cold Side Cart Part No T4.207.13.0.00 , Cac Pipe Cold Side (Cold Start) Cart Part No T4.207.23.0.00 , Cac Piperadiator To Inlet Manifold Cart Part No T4.207.31.0.Pr , Cac Hot Pipe (Turbo Side) Cart Part No T4.207.32.0.00 , Joint Between Cac Hot Pipes Cart Part No T4.207.33.0.Pr , Cac Hot Pipe (Radiator Side) Cart Part No T4.207.34.0.00 , Hose For Thermostat To Radiator Inlet Cart Part No T4.208.01.0.00 , Hose For Thermostat To Radiator Inlet Cart Part No T4.208.07.0.Pr , Dipstick Assembly Cart Part No T4.209.10.0.00 , Joint (For Adaptor) Cart Part No T4.212.05.0.Pr , Cylinder Head Assembly Cart Part No T4.215.30.0.00 , Piston Assembly For 4R810ta Cart Part No T4.216.20.0.Pr , Piston Assembly For 4R810ta Cart Part No T4.216.30.0.Pr , Flywheel Cart Part No T4.217.10.0.00 , Piston Ring Set Cart Part No T4.218.15.0.Pr , Breather Pipe Metallic Cart Part No T4.222.01.0.00 , Fuel Pipe Pre-Filetr To Feed Pump Cart Part No T4.241.02.0.00 , Fuel Pipe Fuel Tank To Fuel Pump Cart Part No T4.241.05.0.00 , Drain Pipe Cart Part No T4.241.24.0.00 , Starter Cart Part No T4.241.26.0.Pr , Fuel Pipe Kit Cart Part No T4.241.90.0.00 , Air Cleaner Assembly350 Kghr90 Deg Bend Outlet I 0 O 23G080755 Cart Part No T4.246.10.0.Pr , Hose Air Suction Id70xid89 Bend Epdm Cart Part No T4.247.02.0.Pr , Fan Assembly 17 5 5 40Deg Pag 1Zl With Spacer S F Modified Wp Cart Part No T4.326.20.0.Pr , Crankcase With Brgcap Cart Part No T4.400.80.0.Pr , Camshaftsub Assembly Cart Part No T4.401.20.0.Pr , Cylinder Head Assembly With Valve Seat Insert And Valve Guide Cart Part No T4.402.20.0.Pr , H Ppipefor Cyl1 Cart Part No T4.407.30.0.Pr , H Ppipefor Cyl2 Cart Part No T4.407.40.0.Pr , H Ppipefor Cyl3 Cart Part No T4.407.50.0.Pr , H Ppipefor Cyl4 Cart Part No T4.407.60.0.Pr , H Ppipefip To Common Rail 1 Cart Part No T4.407.70.0.Pr , H P Pipefip To Common Rail 2 Cart Part No T4.407.80.0.Pr , Aiternator Pulley Pcd 715 Pk Poly V Groove Cart Part No T4.411.01.0.Pr , Exhaust Pipe (Bellow To Egr Cooler In) Cart Part No T4.416.01.0.Pr , Egr Cooler Cart Part No T4.417.01.0.Pr , Adaptoregr Cooler Water In Cart Part No T4.417.02.0.Pr , Adaptoregr Cooler Water Out Cart Part No T4.417.03.0.Pr , Bracketfor Fuel Filter Cart Part No T4.418.01.0.Pr , Fuel Pipe (Fuel Pump To Fuel Filter)For 4R810ta Crdi (57 Kva) Cpcb-Iv+ Cart Part No T4.418.02.0.Pr , Hoseegr Valve Water Inlet Cart Part No T4.419.01.0.Pr , Hoseegr Valve Water Out Cart Part No T4.419.02.0.Pr , Adaptoregr Cooler Water In Cart Part No T4.419.04.0.Pr , Egr Pipeegr Cooler Side Cart Part No T4.421.01.0.Pr , Leak Off Pipe Injector For 4R810ta Crdi (57 Kva) Cpcb-Iv+ Cart Part No T4.424.01.0.Pr , Leak Off Pipe For 4R810ta Crdi (57 Kva) Cpcb-Iv+ Cart Part No T4.424.02.0.Pr , Leack Off Pipe Cart Part No T4.424.04.0.Pr , Header Cart Part No T4.425.01.0.Pr , Lube Oil Header Cart Part No T4.425.02.0.Pr , Special Banjo Bolt (M12x1.5) Cart Part No T4.430.01.0.Pr , Oil Supply Pipe (Turbocharger) Cart Part No T4.430.10.0.Pr , Rocker Support Assembly (Complete) Cart Part No T4.431.30.0.Pr , Thermostat Housing Assly Cart Part No T4.432.10.0.Pr , Turbocharger For 4R810ta Cpcb4 Pluse 54 4Kw 1500 Rpm Cart Part No T4.433.01.0.Pr , Turbocharger For 4R810t Bsv 49Hp Cart Part No T4.433.03.0.Pr , T4 434 06 0 Pr Cri2 16 Injector Assembly 4R810ta Cpcb4 Plus6x144 X300htf Cart Part No T4.434.06.0.Pr , Ecumd1cs162canopy Mounted For Cpcb 4 Plus Project Cart Part No T4.435.01.0.Pr , Cac Hot Pipe Cart Part No T4.437.21.0.Pr , Cac Cold Pipe Cart Part No T4.437.30.0.Pr , Pk Sec Belt 5Pk 1168 (Epdm) Cart Part No T4.438.01.0.Pr , Strech Fit Belt (5Pk1148) For 4R810 Engine Cart Part No T4.438.02.0.Pr , 5Pk Belt For 4R810 Bsv Cart Part No T4.438.03.0.Pr , Control Panel Schematic For 62 5Kva3ph With Kg640 Ip A Cart Part No T4.466.30.0.Pr , Control Panel Schematic For 62 5Kva 3Ph T4ip B Cart Part No T4.467.40.0.Pr , Bracket For Actuator Ecu Mtg Cart Part No T4.472.01.0.00 , Lever For Ele Actuator Cart Part No T4.472.02.0.00 , Stud Coupler 55 Mm Long Cart Part No T4.472.03.0.00 , Engine Control Unit Cart Part No T4.472.04.0.00 , Bracket For Relay Box Mounting Cart Part No T4.473.01.0.00 , Silencer Assembly Cart Part No T4.486.28.0.Pr , Return Fuel Pipe Cart Part No T4.486.37.0.Pr , Silencer Assembly Cart Part No T4.486.39.0.Pr , Fuel Pipe From Fueltank Unit To Pre Filter In Cart Part No T4.486.91.0.Pr , Air Cleaner Hose To Turbo Cart Part No T4.486.92.0.Pr , Fuel Pipe From Pre Filter Out To Fuel Filter In Cart Part No T4.486.93.0.Pr , Fan Assembly Sucker Type Plastic 17 / 5 - 5 / 40°/Pag/1Zl Cart Part No T4.493.10.0.Pr , Silicon Beading Joint For Fanl Tank Spout Cart Part No T4.502.57.0.Pr , Air Cleaner Assembly350 Kg Hr90 Deg Bend I 0 O 57G080789 Cart Part No T4.505.10.0.Pr , Diffuser (Turbo Exhaust To Dop In) Cart Part No T4.522.02.0.Pr , Gasket (For Exhaust Pipe And Doc) Cart Part No T4.522.03.0.Pr , Dpf Egts Subassly 49Hp Cart Part No T4.523.01.0.Pr , V Band Clamp (Docto Mixer) Cart Part No T4.523.04.0.Pr , Gasket(Doc To Mixer ) Cart Part No T4.523.05.0.Pr , Strap For Egt Assembly Cart Part No T4.523.06.0.Pr , 5 66Doc Dpf Assembly 90Outlet Orientation Cart Part No T4.523.10.0.Pr , 5.66Doc+Dpf_Assembly_30°_Downward_Outlet_Orientation Cart Part No T4.523.20.0.Pr , Egt Bracket Assembly Cart Part No T4.523.30.0.Pr , Rocker Cover (Machining) Cart Part No T4.524.01.0.Pr , Ccv Oil In Pipe Cart Part No T4.526.04.0.Pr , Ccv Air Out Pipe Cart Part No T4.526.06.0.Pr , Ccv Drain Pipe Assembly Cart Part No T4.526.15.0.Pr , Turbo Out Hose Cart Part No T4.527.02.0.Pr , Turbo Out Pipe Cart Part No T4.527.03.0.Pr , Gasket Cart Part No T4.527.04.0.Pr , Turbo Supply Cart Part No T4.527.05.0.Pr , Turbo Drain Pipe Cart Part No T4.527.06.0.Pr , Turbo Cross Over Pipe Assy Cart Part No T4.527.10.0.Pr , Oil Supply And Drain Pipe For Turbocharger Cart Part No T4.527.20.0.Pr , Engine Wiring Harness Assembly With Kg934 Unit Cart Part No T4.810.70.0.00 , Engine Wiring Harness Sf 4R810ta Engine Cart Part No T4.820.30.0.00 , 4R810 Flange Heater Wiring Harness Cart Part No T4.821.20.0.Pr , Engine Wiring Harness For 62 5Kva T4 Emerald Cart Part No T4.822.10.0.Pr , Engine Wiring Harness For 62.5Kva Emrald Coldstart Cart Part No T4.822.20.0.00 , Engine Wiring Harness Sf Kg 645 Unit Governor Cart Part No T4.830.20.0.00 , Power Cablepvcfor 62 5Kva 3Ph T4 Emerald Cart Part No T4.910.40.0.Pr , Set Of Joint Cart Part No T4.999.01.0.Sp , Set Of Joint Cart Part No T4.999.03.0.Sp , Connecting Rod Bearing Pair Cart Part No T4.999.05.0.Sp , Set Of Joints Cart Part No T4.999.10.0.Sp , Major Overhauling For Ajax Dumper, Schwing, Backhoe Loader Bull Cart Part No T4.999.11.0.Sp , Top Overhauling For Ajax Dumper, Schwing, Backhoe Loader Bull Cart Part No T4.999.12.0.Sp , Major Overhauling For Jcb Cart Part No T4.999.13.0.Sp , Top Overhauling For Jcb Cart Part No T4.999.14.0.Sp , Major Overhauling For Pg Cart Part No T4.999.15.0.Sp , Top Overhauling For Pg Cart Part No T4.999.16.0.Sp , Wet Pm Kit (W/O Oil) For T4.8941 - 4R810eta Cart Part No T4.999.17.0.Sp , Wet Pm Kit (W/O Oil) For T4.8903, T4.8927 - 4R810ta G1 Cart Part No T4.999.19.0.Sp , Wet Pm Kit (W/O Oil) For T4.8904 Cart Part No T4.999.21.0.Sp , Wet Pm Kit (W/O Oil) For T4.8906, T4.8909, T4.8922, T4.8923, T4.8924 - 4R810ta G1 Cart Part No T4.999.22.0.Sp , Wet Pm Kit (W/O Oil) For T4.8907, T4.8908, T4.8925, T4.8926, T4.8926.Pb - 4R810ta G1 Cart Part No T4.999.23.0.Sp , Electronic Governor Kit: 4R810 Cart Part No T4.999.30.0.00 , Belt Installation Tool Cart Part No T4.999.31.0.Sp , Electronic Governor Kit For 4R810 Cart Part No T4.999.36.0.Sp , Electronic Governor Kit For 4R810 (Emerald) Cart Part No T4.999.37.0.Sp , Bracket Bsv 4R810 Wiring Harness Resting Bracket-1 Cart Part No T4.B049.111.0.Pr , Bracket Bsv 4R810 Wiring Harness Resting Bracket-2 Cart Part No T4.B049.112.0.Pr , Engine Wiring Harness For 49Hp Na Bsv 4R810t Engine Outlet From Flywheel End Cart Part No T4.E049.110.0.Pr , Egt Wiring Harness For 49Hp Bsv 4R810t Engine Outlet From Flywheel End Cart Part No T4.X049.110.0.Pr , Egt Wiring Harness For 49Hp Bsv 4R810t Engine Outlet From Flywheel End For Aja Cart Part No T4.X049.112.0.Pr , Av1 Vr Bush Cart Part No V.001.5.01.003 , Bearing V/R Cart Part No V.038.5.01.703 , Bearing V/R: Ha394 Cart Part No V.073.5.00.703 , Bearing V/R Cart Part No V.074.5.00.003 , Bearing V/R: Ha494 Std Ub Cart Part No V.074.5.00.703 , Bearing V/R Cart Part No V.075.5.00.703 , Bearing T/W 6R1080 (U & L) Cart Part No W.006.3.20.003 , Set Of Bearing T/W: Tv1 Cart Part No W.019.9.00.003 , Bearing T/W: Ra3 Cart Part No W.038.9.00.003 , Thrust Washer: Ig Ra3 Cart Part No W.038.9.10.003 , Bearing T/W: Sl90 Cart Part No W.055.5.00.003 , Bearing Cart Part No W.073.5.00.003 , Bearing T/W Kir Ha 394 Cart Part No W.073.7.00.003 , Thrust Washer Cart Part No W.547.5.00.003 , Thrust Washer Std 4R810 Cart Part No W.552.5.00.003 , 12V, 8Ah Vrla Kirloskar Green Battery Cart Part No Ap1.018.32.0.Pr , 12V Dc, 32Ah, Lead Acid Kirloskar Green Battery Cart Part No Cc1.012.001.0.00 , 12V Dc, 65Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.709.25.0.00 , 12V Dc, 75Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.709.24.0.Pr , 12V Dc, 88Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.709.23.0.00 , 12V Dc, 100Ah, Lead Acid Kirloskar Green Battery Cart Part No 03.793.23.0.00 , 12V Dc, 130Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.731.08.0.00 , 12V Dc, 150Ah, Lead Acid Kirloskar Green Battery Cart Part No 03.793.24.0.00 , 12V Dc, 180Ah, Lead Acid Kirloskar Green Battery Cart Part No 02.731.33.0.00 , Kirloskar Care Genuine Coolant Premix 1 Litre Can Cart Part No 82.020.35.1.01 , Kirloskar Care Genuine Coolant Premix 5 Litre Can Cart Part No 82.020.35.1.05 , Kirloskar Care Genuine Coolant Premix 10 Litre Can Cart Part No 82.020.35.1.10 , Kirloskar Care Genuine Coolant Premix 26 Litres Can Cart Part No 82.020.35.1.26 , Kirloskar Care Genuine Coolant Premix 205 Ltrsbarrel Cart Part No 82.020.35.1.11 , K Clean 1Ltr Can Cart Part No 82.020.35.5.01 , Genuine D.E.F. 10 Litre Can Cart Part No 82.110.20.0.10 , Genuine D.E.F. 20 Litre Can Cart Part No 82.110.20.0.20 , Genuine D.E.F. 210 Litre Barrel Cart Part No 82.110.22.10.00 , Kirloskar Care Super Genuine Oil 1 Liter Can Cart Part No 82.050.10.0.01 , Kirloskar Care Super Genuine Oil 5 Liters Can Cart Part No 82.050.10.0.05 , Kirloskar Care Super Genuine Oil 7.5 Liters Can Cart Part No 82.050.10.0.07 , Kirloskar Care Super Genuine Oil 13 Liters Can Cart Part No 82.050.10.0.13 , Kirloskar Care Super Genuine Oil 20 Liters Can Cart Part No 82.050.10.0.20 , Kirloskar Care Super Genuine Oil 50 Liters Can Cart Part No 82.050.10.0.50 , Kirloskar Care Super Genuine Oil 210 Liters Barrel Cart Part No 82.050.10.2.10 , Kirloskar Care Premium Genuine Oil 1 Liter Can Cart Part No 82.060.10.0.01 , Kirloskar Care Premium Genuine Oil 5 Liters Can Cart Part No 82.060.10.0.05 , Kirloskar Care Premium Genuine Oil 7.5 Liters Can Cart Part No 82.060.10.0.07 , Kirloskar Care Premium Genuine Oil 13 Liters Can Cart Part No 82.060.10.0.13 , Kirloskar Care Premium Genuine Oil 20 Liters Can Cart Part No 82.060.10.0.20 , Kirloskar Care Premium Genuine Oil 50 Liters Can Cart Part No 82.060.10.0.50 , Kirloskar Care Premium Genuine Oil 210 Liters Barrel Cart Part No 82.060.10.2.10 , Kirloskar Care Platinum Genuine Oil 1 Liter Can Cart Part No 82.080.10.0.01 , Kirloskar Care Platinum Genuine Oil 5 Liters Can Cart Part No 82.080.10.0.05 , Kirloskar Care Platinum Genuine Oil 7.5 Liters Can Cart Part No 82.080.10.0.07 , Kirloskar Care Platinum Genuine Oil 13 Liters Can Cart Part No 82.080.10.0.13 , Kirloskar Care Platinum Genuine Oil 20 Liters Can Cart Part No 82.080.10.0.20 , Kirloskar Care Platinum Genuine Oil 50 Liters Can Cart Part No 82.080.10.0.50 , Kirloskar Care Platinum Genuine Oil 210 Liters Barrel Cart Part No 82.080.10.2.10 , Kirloskar Care Gas Genuine Oil 5 Liters Can Cart Part No 82.010.10.0.05 , Kirloskar Care Gas Genuine Oil 20 Liters Can Cart Part No 82.010.10.0.20 , Kirloskar Care Gas Genuine Oil 210 Liters Barrel Cart Part No 82.010.10.2.10 , Kirloskar Care Gold Genuine Oil 50 Liters Can Cart Part No 82.070.10.0.50 , Kirloskar Care - Petro Plus 1.2 Liters Petrol Engine Oil Cart Part No 82.110.30.0.000 , Kirloskar Care Hydraulic Oil_46 Hlp_26 Ltr Cart Part No 82.046.10.0.26 , Kirloskar Care Hydraulic Oil_46 Hlp_210 Ltr Cart Part No 82.046.10.2.10 , Kirloskar Care Hydraulic Oil_68 Hlp_26 Ltr Cart Part No 82.068.10.0.26 , Kirloskar Care Hydraulic Oil_68 Hlp_210 Ltr Cart Part No 82.068.10.2.10 , Kirloskar Care Gear Oil_ 85W-140_5 Ltr Cart Part No 82.065.10.0.05 , Kirloskar Care Gear Oil_85W-140_20 Ltr Cart Part No 82.065.10.0.20 , Kirloskar Care Transmission Oil_Dex Iii_5 Ltr Cart Part No 82.075.10.0.05 , Kirloskar Care Transmission Oil_Dex Iii_17 Ltr Cart Part No 82.075.10.0.17
Contract Date: Dec 30, 2025 Contract Value : 12.53 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
Jammu And Kashmir View Result →
26.
Petroleum and Natural Gas #8419808 AOC
Providing Miscellaneous Services For Maintenance/Upkeep/Cleaning Of All Type Of Equipment, Office And Store Assistance, Housekeeping, Horticulture Works And Handling Of All Materials At Erpl-Bolpur Pump Station-Assistance in condition based monthly/ yearly maintenance of mainline pump including cleaning, refilling of oil, disposal of waste in proper place including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 2 Providing support service in Mainline engine 250 Hrs maintenance by shifting of Glacier filter to workshop, cleaning of filter, disposal of waste in proper place, oiling of fuel rack etc. including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 3 Service support in condition based quarterly/monthly maintenance of compressor including engine of the diesel compressor. Cleaning of filter, external cleaning of cooling pipe and general cleaning of the compressor including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 4 Service support in condition based qtrly/half yearly maintenance of the compressor, Cleaning of filter, external cleaning of cooling pipe and general cleaning of the compressor. Shifting of old lube oil from Air compressor room to sump pump etc. Shifting & cleaning of all parts like valves and heads of Air Compressor, inter stage cooler etc. from compressor room to workshop & back including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 5 Service support in condition based yrly maintenance of the compressor, Cleaning of filter, external cleaning of cooling pipe and general cleaning of the compressor. Shifting of old lube oil from Air compressor room to sump pump etc. Shifting & cleaning of all parts like valves and heads of Air Compressor, inter stage cooler etc. from compressor room to workshop & back including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 6 Service support in condition based qtrly maintenance of centrifuge in shifting of Centrifugal Bowl from shed to workshop and vice versa, cleaning, including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 7 Service support in condition based Half yrly/ yrly/ 2 yrly maintenance of centrifuge in shifting of Centrifugal Bowl from shed to workshop and vice versa, cleaning, including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 8 Assistance in condition based monthly maintenance of fire fighting engine and pump, cleaning of engine & pump including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 9 Assistance in condition based 2 yrly/ 4 yrly maintenance of fire fighting engine and pump, cleaning of engine & pump including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 10 Assistance in condition based monthly maintenance of Jockey pump, cleaning including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 11 Assistance in replacement of engine lube oil in mainline engine (1450 ltrs approx). Lube Oil from engine shed to sump pump, shifting of old & new filter element, shifting of old & new engine oil. Cleaning of engine sump, cam chamber, oil bath chamber and removing old lube oil from pipings including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 12 Providing support service in Mainline engine 1500/3000/1800 Hrs. Maintenance by shifting of heavy components and materials from pump shed to workshop and vice versa. Service support in removal of Breather valve from M/L engines, cleaning and refitting; cleaning of injectors components including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 13 Service support in cylinder head replacement of mainline engine including assistance in removing & fitting of head, cleaning of parts shifting of tools, and tackles as per instruction of EIC/Site Engineer. 14 Assistance in shifting of new lube oil filled drum each 210 ltrs from lubeoilshed to pump shed for top up in mainline engine by operation dept. 15 Support service for condition based Qtrly/ 2 yrly maintenance of DU pump including general cleaning of the unit, Suction strainer cleaning and assistance in Loosening and tightening of the bolts and nuts including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 16 Assistance for condition based Qtrly/ 4 yrly maintenance of sump pump including assistance in general cleaning of the unit and greasing of all the valves including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 17 Assistance for condition based Qtrly/ Hyrly/ Yrly maintenance of OWS pump including assistance in general cleaning of the unit and greasing of all the valves including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 18 Providing support service for condition based Hyrly/ Yrly maintenance of station valves including assistance in general cleaning and greasing including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 19 Providing support service in cleaning of mainline pumping unit including auxilliaries with cotton waste, cloth(supplied by owner) including disposing of all oilly waste into proper dustbinincluding shifting of tools, and tackles as per instruction of EIC/Site Engineer. 20 Providing support services of labour for all other miscellaneous job in station. 21 Providing support services of labour as and when required for assistance in breakdown, predictive proactive maintenance, defective attending and exigency in extended hours. This item will be operated if the service of labour is utilized beyond normal working of 8 hours per day. 22 Cleaning of rupture tank of mainline engine including cleaning of drain line including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 23 Support service for PIG preparation, lunching, retrieving including shifting, cleaning of PIG retrieved from barrel, cleaning of barrel, pit etc. including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 24 Providing assistance in M/L Engine oil filter (lube oil & fuel oil) replacement including shifting of old & new filters (in each bank) including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 25 Cleaning of compressors & fire fighting enginesincluding their starting vessel and pipings etc. including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 26 Providing support service for condition based Hyrly/ Yrly maintenance of Basket Strainerincluding assistance in general cleaningand greasing including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 27 Providing support service for condition based Monthly maintenance of EG at Pump station including assistance in general cleaningand greasing including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 28 Providing support service for condition based Qtrly/ Hyrly/ Yrly maintenance of Foam Pump station including assistance in general cleaning and greasing including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 29 Providing support service formaintenance of DRA Skid including assistance in general cleaningand greasing including shifting of tools, and tackles as per instruction of EIC/Site Engineer. 30 Assistance for refilling of DRA Chemical in storage tank forinjection pumpby operation dept. 31 Cleaning of CF Unit, DMFA Pump, DU Pump, DRA Skid unit, Foam Pump, 250KL Crude storage tank etc.including tools and tackles as per instruction of EIC/Site Engineer. 32 Assistance in condition based monthly maintenance of 800 KVA transformer including cleaning of transformer, oil and winding temperature checking, silica gel replacement, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 33 Assistance in condition based yearly maintenance of 800 KVA transformer including cleaning of transformer, oil and winding temperature checking, silica gel replacement, IR value checking of transformer windings, earthing connection checking, nut bolt tightening, dismantling and reassembling of Transformer terminals, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 34 Assistance in condition based half -yearly maintenance of 11 KV VCB maintenance including IR value measurement and checking, greasing and general cleaning of VCB, tightening of jaw of VCB, checking of electrical controls of VCB etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 35 Assistance in condition based yearly maintenance of Bus duct including cleaning, tightening of nut-bolts, terminal checking complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 36 Assistance in condition based half yearly maintenance of 400 KVA DG including general cleaning, IR checking, tightening of nut bolts, earthing connections etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 37 Assistance in condition based half yearly maintenance of LT motors including IR value checking, general cleaning, panel and terminal block cleaning, greasing, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 38 Assistance in condition based half yearly measurement of earth pit readings inside ERPL, Bolpur including measurement of individual earth pit as well as grid resistance values complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 39 Assistance in condition based half-yearly maintenance of cable trench including general cleaning, cable inspection and checking, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 40 Assistance in condition based half yearly maintenance of bulk storage heater including cable inspection and checking, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 41 Assistance in condition based half yearly maintenance of OWS system electrical panels and related motors including general cleaning, cable inspection and checking, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 42 Assistance in condition based quarterly maintenance of PCC/ MCC Panels at ERPL, Bolpur including cleaning of bus bars, electrical components, checking of control and power system, tightening of jaw, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 43 Assistance in condition based half yearly maintenance of Centrifuge system electrical panels and related motors including general cleaning, cable inspection and checking, etc. complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 44 Assistance in condition based yearly checking of Insulating Joint/Coupling complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 45 Assistance in condition based half- yearly general checking of FLT & High Mast Towers including replacement of light fittings with owner supplied luminaries and associated accessories, greasing of Gearbox and motor of High Masts, cable replacement etc., complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 46 Assistance in condition based half yearly/yearly general maintenance of Mainline Engine Electrical Auxiliaries including IR value checking, General cleaning and panel and terminal block checkingetc., complete in all respect including tools, tackles, etc. as per instruction of EIC/ Site Engineer. 47 Providing support services of labour as and when required for assistance in breakdown, predictive proactive maintenance, defective attending and exigency. 48 Providing support services of labour as and when required for assistance in breakdown, predictive proactive maintenance, defective attending and exigency in extended hours. This item will be operated if the service of labour is utilized beyond normal working of 8 hours per day. 49 Dusting of inside and cleaning of outside surface of various electrical and electronicpanels like PCC, MCC, PLC, UPS, Chargers etc. as per instruction of EIC/ Site Engineer (fortnightly). 50 Carrying telephone instruments for repair/ replacement from control building to site, admin. building, assistance in checking of telephone cables, restoration of telephone service as per instruction. 51 Assistance in taking battery readings, pouring of distilled water, applying petroleum jelly in lead acid batteries, cleaning of battery terminals taking all precautions for safety, cleaning of battery terminals for maintenance free/ sealed batteries taking all precautions as instruction. 52 Assistance during taking reading of equipment, telecom panels, carrying test equipment, laptops, multimeters, straight and cross ethernet cables, tools and tackles etc. for schedule maintenance/breakdown activity as per instruction. 53 Assistance in cleaning of telecom equipment, monitors, routers, switches, connectors, media converters, telecom exchange, telephones etc. as per instruction. 54 Assistance in cleaning of servers, workstations, computer peripherals, shifting of equipment, keeping & arranging various types of cables, adaptors, Software CDs, manuals properlyin racks as per instruction. 55 Assistance in dismantling, calibration, rectification, cable removal and termination, re-installation, leak arrestingin instruments of engines, boosters, MOVs, Fire Fighting engines, Tanks, Compressors, DG, centrifuge, OWS and other field instrument during carrying outschedule maintenance and calibration of instruments in workshop, cleaning of the instruments and assistance in keeping ready for spare & field use as per instruction. 56 Assistance in dismantling, calibration, rectification, cable removal and termination, re-installation of engines during 250 hrs,3000 hrs,9000 hrs and 18000 hrs. schedule maintenance. 57 Providing support services of labour as and when required in dismantling, calibration, rectification, cable removal and termination, re-installation, leak arrestingin instruments of engines, boosters, MOVs, Fire Fighting engines, Tanks, Compressors, DG, centrifuge, OWS and other field instrument during carrying out predictive, breakdown maintenance etc. as per direction of EIC/Site Engineer. 58 Providing support services of labour as and when required for assistance in breakdown, predictive proactive maintenance, defective attending and exigency in extended hours. This item will be operated if the service of labour is utilized beyond normal working of 8 hours per day. 59 Support service for Operation of oil water separator/sumpincluding cleaning, servicing of various equipment/crude tank in general Shift including Sunday, holiday(including monsoon period/ rainy day) the year as per direction of Engineer-in-Charge. 60 Support service for Operation of oil water separator/sumpincluding cleaning, servicing of various equipment/crude tankin beyond general shift including Sunday, holiday(including monsoon period/ rainy day) as per direction of Engineer-in-Charge. 61 Assistance for up keeping & segregation of registers, document photocopy, maintaining dispatch register, file shifting, preparation & servicing of tea/ coffee etc.as per instruction in general shift duty. 62 Assistance for keeping record of incoming & outgoing materials, maintaining materials register for spare, consumption record, materials staking in proper order, up keeping of store etc. as per instruction. 63 Assistance for up keeping of registers, document photocopy, maintaining dispatch register, file shifting, preparation & servicing of tea/ coffee etc.as per instruction beyond general shift duty. 64 Providing service support during 9000/12000/18000 hrs major maintenance of Mainline Pumping Units including dismantling, cleaning & fitting back of cylinder heads, turbocharger and associated ducts, jacket water header, exhaust header, injectors, fuel pumps, rocker arms, tappet covers, pistons, liners, connecting rods, Pumps, Pump seal, damper etc. Handling/shifting of various components of engine,pump and gearbox, loading& unloading of spares in vehicles as per requirement, emptying out oil from engine/GB/Pump/DSTs, shifting of lube oil barrels, draining of Jacket water/coolant/fuel/lube/diesel circuits, engine lube oil sump, oil bath filter sump, descaling of diff parts, cleaning of DSTs and oil bath filters mesh, C/A intercoolers. Filling of jacket water/coolant, lube oil in engine sump, oil bath filter sump,etc, and other associated works. Whole work is to be completed withing 24 working days. 65 Cutting grass and removal of the same outside the boundary area within 3 km lead all as per direction of EiC. (5500 sqm per month) 66 Vim powder / cleaning powder 67 ISI grade phenyl 68 Acid / Naphtha Ball 69 Coir Brushes / wire brushes 70 Finit. 71 Supplying & providing odonil cake (small)in wash basins, w.c. & other specified places as instructed. 72 Regular removing of cob web, spider nets, from all rooms, ceilings of Control Building, compressor room, lub.shed, store etc. complete 73 Regular removing of cob web, spider nets, from all rooms, ceilings of Pump shed,Fire fighting pump shed, Security room, water pump shed, foam pumpshed etc. complete 74 Maintaining all the rooms of the control building at pump station by daily cleaning through mechanical or other means including daily removal of garbage from waste paper baskets of the pump station complex and throwing the same to outside of boundary wall as directed. 75 Maintaining all the tables, chairs and other furnitures, equipments of the control room, all rooms of adm. building, security room by daily dusting off & swabbing (with water). 76 Cleaning & sweeping of all the roads, approach roads to the brick pavements, plinth protections of the pump station & tank farm. 77 Regular maintenance of lawn,hedge border plants, trees/ shrubs including weeding out all undesirable vegetation growth,watering forking & applying of manure, insecticides etc. with all labours tools, tackles complete as per direction of EIC (Total area approx 8000sq. M) Rate isper sq.m. per month. 78 Regular maintenance of trees & shrubs including weeding out all undesirable growth, watering forking & growth of plants including cutting of unwanted trees and trimming of branches of trees etc. as per direction of EIC with all labour manure, insecticides, etc. 79 Supplypreparation and application of brickcolour/ Ala wash/ Lime wash as and when required on the brick/tub & other area as per the direction of EIC including all labour tools, tackles complete in all respects. 80 Supplying at site manure & cowdung & good earth of approve quality by the Engineer- in- Charge including carrying, transportation, loading, unloading i.e. manpower, materials all inclusive. 81 Supplying and planting essential flowers annual flowers in flower bed including preparation of soil, application of required inclusive of all labour, tools, tackles etc. complete in all manure, medicine and water as and when required inclusive of all labour, tools tackles etc. complete in all respects . 82 Supply and planting seasonal flowers, annual flowers in flower bed including preparation of soil, application of manure, medicine and water as and when required inclusive of all labour, tools, tackles etc. complete in all respects- HYBRID VARIETIES 83 Cleaning, dusting & removal of stains of electrical fittings like ceiling fans, wall mounted fans and tube light fittings, etc. of the Control Building, Store, Security,Lubeshed,Compressor room,Pump shed, F/F shed etc complete as per direction of EIC/Site Engineer. 84 Cleaning of drinking water tanks located at the roof top of the buildings with bleaching/detergent or any other solvent/ powder with all labour and materials complete. 85 Cleaning & stripping bushes, grass, jungle, vegetation, shrubs, etc. including uprooting and collecting rotten hogla and removal of the same outside the boundary wall for a lead upto 5 km, dewatering if required, with all labour, tools & tackles and materials complete. 86 Cleaning of entire surface drains including removal of all rubbish, garbage, bush, uprooting vegetations (both sides of drain), debris, muck and all unwanted materials including throwing outside of the compound wall, including supply of all tools tackles required for the operation. 87 Cleaning soak pit 2.5m dia and disposal of unwanted materials to a distance of 500m 88 Material Loading, Unloading, shifting & handling of all types of materials such as loose pipes (bare/in bundles), fittings (loose/in lot), valves, electrical & instrumentation items and various other materials etc as received in packed/unpacked condition/wooden crates/boxes/pallets etcfromtruck/trailer using hydra with valid Fitness certificate issued by RTO and Load test certificate issued by competent authority & necessary insurance, to be carried out as per directions of Engineer-In-Charge/Site Engineer including cost of labour, slings, D shackles, tools & tackles etc. as required for proper handling of materials with necessarysafety precautions including the cost of Personal protective equipment such as helmets, safety shoes, hand gloves etc. and complete in all respects. 89 Manual handling of material such as loading/ unloading, packing/ unpacking, shifting, greasing, removal of rust, applying primer/paint over metal surfaces of pipes/fittings, vlaves etc and various miscellaneous jobs at material store yard/plant premises as required to complete the jobas per directionEIC/site engineer including cost of labour, tools, tackles, insurance of labour etc., considering all necessary safety precautions including the cost of Personal protective equipment such as helmets, safety shoes, hand gloves etc and complete in all respects.
Contract Date: Dec 11, 2025 Contract Value : 43.53 Lakh
Boards / Undertakings / PSU No of Bidders 2
West Bengal View Result →
27.
Educational and Research Institute #8391425 AOC
Repair, Renovation, And Reconfiguration Of Lab 1 At The Computer Engineering And It Engineering Department, First Floor, Vjti, Matunga, Mumbai.= 1 Dismantling of existing partitions, wall paneling, etc., all complete as per site requirements, and stacking the usable materials within building premises as directed by the Architect/Consultant/ Engineer-in- Charge, etc. complete. (Lead Upto 100 meters) 2 Removal of cement tiles, existing flooring, wall tiles,marble, polished Shahabad flooring, dado with or without bed concrete, including stacking the materials as directed, with all leads, lifts, etc., complete. (Lead Upto 100 meters) 3 Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. complete. ( Lead upto 100 meters) 4 Scraping the old paint from the plastered internal surface using a dust-free vacuum paint scraper, followed by coating the entire surface with a mixture of whiting or glue and linseed oil, including the provision of scaffolding, as directed. (The scraping of old paint should be done until the neeru finish of the plaster is achieved.) Lead and Lift upto 100 meters etc. Complete. 5 Removing old paint from steel and other metal surfaces and making the surfaces even with hand scrapping, scaffolding etc. complete. 6 Removing the existing cement plaster of any thickness without causing dust nuisance, stacking the debris up to a distance of 100 meters, cleaning the site, etc. complete. 7 Providing and applying an anti-corrosive chemical to exposed reinforcement of R.C.C. members such as beams, columns, and slabs. This includes one coat of alkaline rust converter (Feovert, Rusticide, or equivalent) after cleaning the surface with a wire brush, followed by two coats of anti-corrosive, epoxy-based, two-component, zinc-rich primer (Materemaco P 130 of BASF, Phenolic IPNET RB, Polyalk Flxoprime, or equivalent) for rebar protection on exposed reinforcement. Additionally, apply a concrete-penetrating corrosive inhibitor (EPCO KP-100, POLALK EP 113, MasterSeal 1414 of BASF, FOSROC, or equivalent) over the adjoining concrete surface. etc. Complete. 8 Providing and applying a bond coat of approved epoxy resin (MasterBrace 1414 of BASF, EPI Bond of Krishna Conchem, or equivalent) before polymer plaster or concrete to ensure a perfect bond between old concrete and new concrete/polymer plaster surfaces. The bond coat should be applied within half an hour after preparation, conforming to ASTM C881 Type 2. This process includes the use of nylon brushes, scaffolding, labor, etc. Complete. 9 Providing and applying ready-mix polymer-modified cement mortar with an average thickness of 15mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. The surface should be cured after 72 hours of application using wet gunny bags, etc. Complete. 10 Providing and applying ready-mix polymer-modified cement mortar with an average thickness of 30mm-50mm, using polymer in one or more layers, in a proportion of 1:5:15 (polymer, cement, and quartz sand) as per the manufacturers specifications. The surface should be cured after 72 hours of application using wet gunny bags, etc. Complete. 11 Providing and applying a 30mm thick self-curing Ceramic Polymer Microconcrete of an approved make, having a compressive strength above M30, non-shrink, and impermeable, as a filling mortar for load-carrying R.C.C. members in two layers on cleaned concrete surfaces, including honeycomb areas (using manual or mechanical means). The mortar shall be prepared by mixing Nicosil C80 and fresh 53-grade cement with the required water-cement ratio to achieve the desired consistency. The application and finishing shall be done by manual trowelling. Curing shall be carried out after the initial setting time, in accordance with the manufacturers specifications. The work shall be executed in line with the specifications and as directed by the Engineer-in-charge. The work must be carried out by a certified applicator, and the work shall be guaranteed for 5 years. The guarantee shall be provided on a Rs. 500/- stamp paper. (The bond coat, as per item No. 08 in the BOQ, is to be applied before the coating.) 12 Providing and applying 12mm thick internal/external ready-mix plaster conforming to IS: 4031 (Part-4) 1988 and IS: 383-1970, in a single coat using cement mortar in a proportion of 1:4, with a special type of polymer additive (approximately 0.4%), on all types of surfaces in all positions, including scaffolding and curing. The plaster shall be followed by a smooth finishing coat of gypsum plaster of 6mm thickness, ensuring an even, smooth surface suitable for painting. Complete with necessary curing, scaffolding, and all other related works. 13 Providing and applying a priming coat over new/old steel and other metal surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter. The surface shall be scoured with wire brushes, fine steel wool, scrapers, and sandpaper, with scaffolding as required, etc. Complete. 14 Providing and applying priming coat over new wood and wood-based surfaces, including preparing the surface by thoroughly cleaning oil, grease, dirt, and other foreign matter, sanding, knotting, scaffolding, etc., complete. (Brands such as Asian Paints, Dulux Paints, Nerolac, Berger, Royal, or equivalent make.) 15 Providing and applying two coats of synthetic enamel paint of approved color to new/old structural steel work and woodwork in buildings, including scaffolding if necessary, cleaning, and preparing the surface (excluding primer coat). etc. Complete.(Brands such as Asian Paints, Dulux Paints, Nerolac, Berger, Royal, or equivalent make.) 16 Removing and refixingof doors and windows with frames and stacking the materials as directed, including all leads, lifts, labour, fitting etc., complete. (Lead up to 100 meters) 17 Providing and laying in pattern 600 mm x 600 mm Vitrified Tile flooring of 8 to 10 mm thickness and confirming to IS 15622-2006 ( group Bla) of approved make,quality, shade and pattern for flooring . The tile flooring shall be laid in pattern with 2 mm spacers & tiles fixed in cement mortar of 1:4. The Rate shall be including floor chipping to attaining required levels, epoxy grouting of joints using approved matching colour tile grout of epoxy grout, necessary protection of the laid floor, acid wash cleaning for any stains before handover. etc. complete as per the drawing, specification and to complete satisfaction of the Engineer. Rate to include the wastages as per the pattern indicated in the layouts. Brands Like Kajaria, Johnson or Similar etc. Groove shall be filled with grout of approved shade ( Brands like Laticrete etc.) as dicectedby the Engineer-in-charge. etc. complete. Basic rate for tile material- Rs. 1440/- per Sq.m. 18 Providing and fixing skirting, including labor, materials, and all related work, etc., complete. Rate for skirting of height up to 150 mm. 19 VINYL FLOORING FOR HOD CABIN:Providing and fixing approved color homogeneous flooring, 4mm thick with interlocking system, single-layered flexible SPC vinyl flooring (Spica by Tusker Vinyl Floorings) in roll form, over the provided I.P.S. or Kota stone flooring. The flooring will be fixed using approved adhesive, and all joints will be soldered with PVC rods as per the manufacturer’s specifications. The work will be completed as directed, ensuring proper leveling and cleaning. The roll width will be a minimum of 2.0 meters, and the weight of the PVC flooring will be 90 kg per 30 sqm. as directed and approved by Engineer in Charge. etc complete. basic rate for vinayl flooring material- Rs. 900/- per Sq.m. 20 Providing and laying vitrified mirror/glossy/Matte finish tiles of size 590 mm to 605 mm x 590 mm to 605 mm with a thickness of 8 to 10 mm, conforming to IS 15622:2006 (Group B1A) from an approved make, shade, and pattern, for dado and skirting in the required positions. The tiles shall be fixed in 1:4 cement mortar, including neat cement float, filling of joints, curing, cleaning, and all related work, etc., complete. Basic rate for tile material- Rs. 790/- per Sq.m. 21 Providing second-class burnt brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in the superstructure, including striking joints, raking out joints, watering, scaffolding, and all related work, etc., complete. 22 Lowering the debris obtained from breaking and removing cement plaster/burnt brick masonry from the first floor by any means, without causing dust nuisance or damage to the structure. The debris shall be stacked as directed by the Engineer-in-Charge, including cleaning the site, etc., complete. (Lead up to 100 meters.) 23 Removing and disposing of debris from the site to a dumping ground outside the VJTI premises (in accordance with municipal rules), etc. complete. as directed by the Engineer-in-Charge. (Minimum 6 Cu.m debris per trip) 24 Providing anti-termite treatment to the wooden frames of doors and windows of the existing building as per I.S. 6313 (Part-III), by drilling 6 mm dia. holes at the four corners on one side and the four corners on the other side, at a downward angle of approximately 45 degrees at the junction of the woodwork and masonry. Injecting 150 ml of Chlorodane 5% W.C. into each hole and sealing with putty, etc., complete, with a 2-year guarantee on bond paper. 25 Providing and applying waterproof melamine polish of the required finish to the woodwork by spray machine, including knotting and preparing an even surface by scraping, applying French polish, scaffolding if required, etc., complete.Note: The work is to be executed only with prior approval from the Superintending Engineer. (Brands such as Asian Paints, MRF Melamine or equivalent.) etc. complete. 26 Providing and fixing SS T/U/L strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.Shape: T/U/L ProfileMaterial: SS 304 Grade Stainless SteelDimensions: 8 mm to 12 mmLength: 2440 mm (8 feet), 3048 mm (10 feet)Type: T-SectionFinish: PolishedPosition: InteriorColor Options: Gold, Rose Gold, Black, Silver, Champagne, Antique Hairline, Antique CopperThickness: 2 mm to 8 mmNote: The shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. Basic rate for material- Rs. 850/- per Number. 27 Providing and fixing SS T/U/L strip profiles for walls, ceilings, tiles, flooring, main doors, interior decoration, bathrooms, and living rooms, including transportation, wastage, labor, etc., complete.Shape: T/U/L ProfileMaterial: SS 304 Grade Stainless SteelDimensions: 16 mm to 32 mmLength: 2440 mm (8 feet), 3048 mm (10 feet)Type: T-SectionFinish: PolishedPosition: InteriorColor Options: Gold, Rose Gold, Black, Silver, Champagne, Antique Hairline, Antique CopperThickness: 2 mm to 8 mmNote: The shape, pattern, color, and design will be directed by the architect/consultant/or engineer in charge. Basic rate for material- Rs. 850/- per Number. 28 Providing and Fixing SIgn Boards Foor Doors:Specification for Waterproof Signage Boards (12 x 4 Inch)Size: 12 inches (L) x 4 inches (H) (with size tolerance is Plus or Minus 1%)Material: High-quality, durable acrylic or PVC boardFinish: Glossy or matte finish for clear readabilityWaterproof: Weather-resistant, suitable for both indoor and outdoor useDesign: Custom text, graphics, or logo engraving/printingMounting: Wall-mountable with adhesive backing or screw mountsColors: Available in multiple colors with contrast for visibility (e.g., white, black, silver)Application: Ideal for office cabins, rooms, labs, and other signage needsThis durable, waterproof signboard ensures clear and professional signage in various environments. including wastage, etc. complete. Basic rate for material- Rs. 460/- per Number. 29 Providing and Fixing of 3D Wall Panels that can be painted as well.Size of each panel: 2 x 2 feet.Colour: Any color, design, or pattern.Features: Lightweight, fire-resistant, easily DIY, 100% recycled.Made from natural bamboo plant fiber, etc., complete. Basic rate for material- Rs. 450/- per Number. 30 Providing and fixing Wooden Decorative Fluted Wall Panels/Louvered Wall Panels:Material: High-quality wood (MDF, plywood, or hardwood) with a decorative veneer finish.Dimensions: 8 feet x 4-5 inchesThickness: 8 mm - 12 mmDesign: Fluted design with vertical or horizontal grooves for a decorative effect.Color: Multicolor/Any Colour. (customizable to match interior themes).Shape: Rectangular panels for seamless installation, etc., complete. Basic rate for material- Rs. 850/- per Number. 31 Providing and fixing machine cut mirror polished 16 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete. One side polishBasic rate for granite material- Rs. 2530/- per Sq.m. 32 Providing and fixing oval-type under-counter wash hand basin of 16-inch x 22-inch size and of special color shade, having telephonic black/colored granite of 180mm thick stone black Kadappa framework, including chromium-plated coupling bottle trap. The wash basin should be of CERA company or equivalent, model no. 3448, as per the detailed drawing or as directed by the engineer-in-charge, etc., complete. (Counter size 1.20m x 0.60m). (Brands such as jaquar,kohler or equivalent make.) Basic rate for wash basin - Rs. 6000/- per Number. 33 Providing and constructing a granite kitchen platform with the installation of a stainless steel sink (600mm x 450mm) as per the detailed drawing, including vertical polished Kadappa stone supports (25 to 30mm thick) on both sides, with a Kadappa top (35 to 40mm thick) and a polished granite top (16 to 20mm thick). The platform will feature granite strips at the front and both sides, with two vertical granite supports (15 cm height). The top granite will be 75 cm x 40 cm, including cutting and opening for the sink of the required size in both Kadappa and granite. The platform size is 5.00 m x 0.60 m, with a height of 0.75 m, etc. complete with all required finishing. Basic rate for SS Sink- Rs. 6000/- per Number. 34 Supply and Installation of 600x600mm Modular Metal Perforated Grid Ceiling System (CG-01)The ceiling system shall be supplied and installed as per the specifications provided in the tender document, and in accordance with the directions and approval of the Engineer-in-Charge. The scope includes complete installation with all necessary materials, components, and finishing to ensure proper execution etc. complete. 35 Providing and Installation of ALUMINUM FRAME WORKS FOR PARTITION WITH PLY ON BOTH SIDES AND LAMINATE FINISH: Providing and Fixing partition Aluminum Frame work consist of 25mm x 50mm x 1.2mm thick extruded Aluminium box section framework at spacing not exceeding 600mm centre to centre both ways (horizontal and vertical). The framework shall be secured at floor structural ceiling and sill/ Lintel level with 25 x 50mm x 1.2mm thick horizontal Aluminium section. Framework to be secured to Floor / Walls / Columns / Ceiling / Beams using 75mm metal screws and dowels.Acoustic Infill: Providing & fixing Acoustic insulation of approved make to G.I./ Aluminum/ MS/ Wooden frame partition of 50mm thick Rockwool of density 48 Kg/m with blanket wrapped in RP tissue suitably affixed to partition framework using where necessary GI binding wire duct tape as indicated in the drawing.OUTER SKIN:- Providing and Fixing 18mm Plywood of brands like GREENPLY, Century or equivalent. Finished with 1 mm thick laminate of approved shade applied on plywood of brands like Formice, Royal touche or equivalent brand.Note: Rate is as per aluminum framework with both side ply and laminate. etc. complete. 36 Providing and Fixing of LAMINATE CLADDING WITH PLY BACKING:Providing and fixing 12mm BWR Plywood (Brand: GreenPly, Century, or equivalent), directly fixed to the column. A 1mm thickness laminate of an approved shade, applied on the plywood surface. Laminate brands: Formica, Royal Touche, or equivalent. etc complete. 37 Providing and Installation of GLASS PARTITION (TOUGHENED GLASS): Providing 12mm toughened fixed glass partition including all patch fittings, ensuring smooth and even flush joints between glasses, fixing the same in positions to true line and level, finishing the wall joints with clear silicon sealants, cleaning the surface and ensuring that there are no scratch marks on the glass etc. complete as per drawing and specifications, Glass brands should be DORMA, OZONE or equivalent. 38 Providing and Installation of GLASS PARTITION (DGU GLASS): Double-glazed unit glass with air spacer of 6 to 16mm, 95% transparency, etc. complete as per drawing and specifications, DORMA or OZONE or equivalent. 39 Providing and Installation of 12mm thick Clear toughened Glass Door with film as required. (D2 - 0.91 X 2.10 m) Specification:Hardware: Door to be complete with hardware to each leaf as follows: Hinges: 8 nos. SS ball bearing butt hinges. Door closer: Concealed door closer with hold open. Lock set: Dead lock as approved.Door Handles:900mm HT. 36mm Dia D Type offset handle on both sides in approved powder coating. Door stop: Floor mounted door stopper as approved Seals: Drop down floor seal as approved. Security System: NA Note: All the metal profile sections and hardware finish should match the frame. Brands like DORMA OR Ozone or Equivalent. etc. complete as per drawing and specifications. 40 Providing and Installation of D1 - Double door two-way sliding motorized door, suitable for door openings up to 1.20 meters with a maximum door weight of 100kg (both leaves). The door offers environmental protection with a working temperature range of -20°C to +50°C and is rainproof. It has a standard opening time of 3-8 seconds, with a remote control operating distance of 100 to 200 feet (depending on line of sight). The opening size is 2.4m x 2.10m, and the glass door size is 1.2m x 2.10m. Brands like DORMA, Ozone, or equivalent, to be installed as per drawing and specifications. etc. complete. 41 Providing and Installation of D3 - 1.09m x 2.10m (single shutter) 12mm toughened glass door with fixed side panels, including all patch fittings, locking mechanisms, and ensuring smooth, even flush joints between the glass panels. The door is to be fixed in position to true line and level, with wall joints finished using clear silicone sealant. The surface should be cleaned and inspected to ensure there are no scratch marks on the glass. Installation to be completed as per drawing and specifications, with brands like DORMA, OZONE, or equivalent. etc. complete. 42 POP Punning: Providing and applying of Plaster of Paris Punning(1st Quality ISI approved POP) over plastered with minimum thickness of 8mm-12mm to existingwall surfaces, ceilings & concrete members etc., to be finished in line and plumb with smooth surface ready to receive paint base. Rate to be inclusive of edge protection (GI), fibre mesh for service conduits,hacking wall surfaces for better bonding, cleaning, scrubbing the surface, providing grooves if necessary etc., complete as per Architects/Consultant/Engineer-in-Charges approval. Brands like Gyproc, Armstrong, SHERA or Equivalent etc. Complete. 43 Plastic Emulsion Paint (LEED Compliant, Low VOC): Providing and applying Plastic Emulsion paint finish to walls, partitions, and ceiling surfaces of approved make, color, texture, and shade in two coats, with surface and finish acceptable to the Engineer in charge to be achieved within these two coats. Any additional coats, if required, shall be at the contractors cost. The work includes preparing existing surfaces by scraping away loose particles, dust, etc., washing and scrubbing, filling cracks with crack filler and binder, cleaning and making the surface dust-free, applying water-based RJ London putty as directed, rubbing with sandpaper to smooth the surface, and applying one coat of primer as recommended by the approved paint manufacturer. The work also includes providing necessary scaffolding, cleaning, and protecting the site until handover, as well as masking and protecting all service devices such as switchboards, detectors, etc. The work is to be completed at all heights and leads, as per specifications or as directed by the Architect/Engineer in charge/Consultant. Brands like Asian Paints, Berger, or equivalent are acceptable. etc. complete. 44 Providing and applying Premium Decorative Wallpaper High-End or Custom Designs (Special Finishes, Custom Patterns)Specifications: Material: Non-woven fabric or vinylRoll Size: 21 inches wide x 33 feet long (covers 55 sq ft)Pattern: Various styles (floral, geometric, etc.)Finish: Matte, Gloss, or TexturedInstallation: Peel & Stick or PasteFeatures:Scratch & water-resistantEasy to clean (wipeable)Fade-resistantEco-friendly, VOC-freeIdeal for: Living rooms, offices, and accent wallsMaintenance: Clean with a damp cloth, no harsh chemicalsCustom Options: Available in various colors and patterns, custom designs upon request. Basic rate for wallpaper Rs. 600/- per SQM. 45 Standing Platform (300-450 mm from FFL):Construction of a standing platform at a height of 300 mm to 450 mm from the Finished Floor Level (FFL), as per approved dimensions. The platform will be made of 18 mm thick wood (Century, GreenLam, or equivalent) and finished with wood polish (Asian Paint Wood Tec, MRF, or equivalent).Materials:Frame: Mild steel or aluminum, powder-coated for corrosion resistance.Surface: High-quality plywood, MDF, or approved materials with a non-slip finish.Support: Sturdy metal beams or supports for stability.Features:Height: 300 mm to 450 mm from FFL, as per design.Finish: Non-slip surface with smooth edges and protective coating.Safety: Non-slip tread and optional guardrails. etc. complete. 46 Stage Flooring: Supply and installation of interlocking rubber tile flooring at the stage area as per the specifications and drawings provided. The flooring will consist of a 6.0 mm synthetic sport surface, including a ≥1.50 mm PUR Protect® treated vinyl surface layer, calendared and grained, supported by a PVC density single closed-cell foam, and reinforced with a fiberglass grid structure. It will feature Sanosol treatment for fungistatic and bacteriostatic properties. The flooring will meet the following standards: Weight: 3.7 kg/m², Impact resistance (EN 1517) ≥8 N/m, Abrasion resistance (EN ISO 5470-1) ≤350 mg, Shock absorption (EN14808) ≥25% (Labosport Result = 28%), Indentation resistance (EN 1516) ≤0.5 mm, Ball bounce (EN 12235) ≥90%, Vertical deformation (EN 14809) ≤3.5 mm, Sliding coefficient (EN 13036-4) 80–110, Fire (EN 13501-1) Cfl-s1, Anti-Viral activity (human coronavirus 229E) – ISO 21702 (99.37% after 2 hours), Energy return (NF P 90 203) ≥0.31 m/s, TVOC after 28 days <100 micrograms/m³ (ISO 16000-6), Floor Score®, CE Marking, EN14904 compliant for multi-sports use, REACH compliant, and Singapore Green Label certified. The supply and installation will include making good any damaged surfaces using standard fillers such as Birla white cement, cement-based grout, epoxy grout, or mortar, and repainting to match the color.All work will be completed in accordance with the specifications, design, drawings, and the direction of the Engineer-in-Charge. 47 Providing and Fixing of Overhead Storage as per the Specifications and Drawings Provided in the tender document. Etc. complete. 48 Providing and Fixing of Surface Storageas per the Specifications and Drawings Provided in the tender document. Etc. complete. 49 Providing and fixing on-site a lab table as per the Specifications and Drawings Provided in the tender document. Etc. complete. 50 Providing and fixing of Office Desk/Table in Faculty Lounge as per the Specifications and Drawings Provided in the tender document. Etc. complete. 51 Providing and fixing of Office Desk/Table in Office for HOD as per the Specifications and Drawings Provided in the tender document. Etc. complete. 52 Supply and installation ofhod cabin chair as per the Specifications and Drawings Provided in the tender document. Etc. complete. 53 Supply and installation of Faculty Lounge Chairs as per the Specifications and Drawings Provided in the tender document. Etc. complete. 54 Supply and installation of study chairs for Labs as per the Specifications and Drawings Provided in the tender document. Etc. complete. 55 Supply and installation of foldable desklet tables for the Seminar Hall as per the Specifications and Drawings Provided in the tender document. Etc. complete. 56 Removingthe exisitng light fixures, fans, wires, cables, swith boards and distribution boards etc. complete. 57 Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WG-PW/SW. (Brands for conduits Precision/Finolex/Pressfit. and For Cable Barnds should be Polycab/Finolex/Havells. etc. complete 58 Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 2.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WG-PW/SW. (Brands for conduits Precision/Finolex/Pressfit. and For Cable Barnds should be Polycab/Finolex/Havells. etc. complete 59 Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A / 25A switch combined with indicator lamp and fuse with gang box on wooden board.Make /brand (Roma/ legrand,/ Greatwhite) etc. complete 60 Supplying and erecting ISI mark modular type 3 pin 6A / 16A multi socket with safety shutter, duly erected on providedplate and box with wiring connectionsetc.complete. Brand : Roma/gretwhite/legrand) etc. complete 61 Supplying and erecting PVC Surface modular double mounting plate 3 modules complete duly erected etc complete.(.Brand Roma/gretwhite/collar) 62 Supplying and erecting PVC Surface modular double mounting plate 4 modules complete duly erected etc complete.(.Brand Roma/gretwhite/collar) etc. complete 63 Supplying and erecting PVC Surface modular double mounting plate 6 modules complete duly erected etc complete.(.Brand Roma/gretwhite/collar) etc. complete 64 Supplying and erecting PVC Surface modular double mounting plate 8 modules complete duly erected etc complete.(.Brand Roma/gretwhite/collar) etc. complete 65 Supplying and erecting PVC Surface modular double mounting plate 12 modules complete duly erected etc complete.(.Brand Roma/gretwhite/collar) etc. complete 66 Supplying and erecting regular/ standard model ceiling fan of 1400mm with sweep complete erected in position as per specification no. FG-FN/CF Brand /Orient/Polycab/Crompton etc. complete 67 Supplying and erecting flush-type ceiling fan regulators and electronic step regulators for ceiling fans (600mm, 900mm, 1200mm, and 1400mm sweep), complete with installation on the provided switchboard. Make/Brand: Roma, Legrand, or Greatwhite. 68 Providing and fixing 36 watt 2X2 light fitingSupplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W includingmotion sensor LED light with provision for plane front frame with translucent cover fixed to the housing etc.complete .Brand Philips/Havels/Wipro etc. complete 69 Supplying and erecting 16 to 32 A DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. (Make/ Brand: Legrand/ schneider/ L&T/ Indo Asian) etc. complete 70 Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 (Make/ Brand: Legrand/ schneider/ L&T/ Indo Asian) etc. complete 71 Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/tripalarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB (Make/ Brand: Legrand/ schneider/ L&T/ Indo Asian) etc. complete 72 Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB. (Make/ Brand: Legrand/ schneider/ L&T/ Indo Asian) 73 Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW etc. complete. Cables Brands should be Polycab/Finolex/Havells. etc. complete 74 Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC. Cables Brands should be Polycab/Finolex/Havells. etc. complete. 75 Supplying & erecting mains with 2 x 2.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20mm dia. as per specification No: WG-MA/PC.etc complete. Brand :polycab/Finolex/havels) etc. complete 76 Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no.CB-LT/CU(Brand: Polycab/ Finolex/ Havells)Note - The quantity of wires for looping the required number of air conditioning units has to be calculated by the contractor with respect to the provided architectural working drawing. etc. complete 77 Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. Cable Tray Brands should be Profab or equivalent. etc. complete 78 Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. etc. complete (Make/ Brand: Legrand/ schneider/ L&T) 79 Supply & Fixing of Aluminum box section to be laid on the floor with all excavation, re-cementing & refinishing civil works to make good in line with the existing floor level Respective junctionbox to be fabricated in 16 SWG GI sheet with cut out as required for terminating the box sections. Shall include PVC conduits from JB to work station Powerpoints i)150 x 150x 50 mmGIJunction box with cover & cut outs etc. complete. (Make/ Brand: Legrand/ schneider/ L&T) 80 Supply of A.C SPLIT UNIT (2 TON) :Supply of AC Split unit as per the specifications, and drawings provided in Tender Document. Make (Carrier/ Voltas/ Bluestar/ Samsung) etc. complete 81 Supply of 2 Ton Casatte Ac:2 ton inverter casette AC. Cooling capacity 3200-8000 watt. Offers uniform 360 degree round Airflow, with 4 star energy rating. Etc. complete. Make (Carrier/ Voltas/ Bluestar/ Samsung) etc. complete 82 Installation of 2 Ton AC Split Unit etc. complete 83 Installation of 2 Ton AC Cassette Unit etc. complete 84 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 85 Supply & installation electrical communication cable between indoor to outdoor units.Cables Brands should be Polycab/Finolex/Havells. etc. complete. 86 Providing and fixing in position MS frame Stand for A.C. units, floor or wall mounted, with vibration isolation pads and frame to be made out of required MS sections strong enough to hold the weight of the AC unit,and should be lockable, including fixing in position using necessary scaffolding, ladder etc, and painting with two or more coats ofapproved enamel paint on a coat of red oxide etc. complete 87 Insulated Condensate Water Drain piping constructed out of PVC / HDPE hard pipeswith 6mm thick nitride insulation, fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors Fasteners and concealed in brickwork or flooring. etc. complete(Make: Finolex/ Astral/ Prince) 88 Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system. etc. complete. material selection should be high quality and from reputed brand as directed by engineer in charge. 89 Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. etc. complete 90 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. etc. complete 91 Supply and Installation of Roller Blindsas per the Specifications and Drawings Provided in the tender document. Etc. complete. basic cost for blind cloth fabric material Rs.900/- per Sq.m. 92 Carrying out Test for CERAMIC TILES / VITRIFIED TILESWater Absorption, Modulus of Rupture (Set of 6 Tiles) etc. complete. 93 Carrying out Test for PLYWOOD: Determination of Resistance to dry heat,Determination of Moisture Content,Determination of Density,Thickness of Plywood. etc. complete. 94 Carrying out Test for Test for Glue Adhesion for plywood etc. complete. 95 Carrying out Test for HOLLOW / SOLID /AAC BLOCKSDensity Test. (Set of 3 Blocks), Compressive Strength. (Set of 3 Blocks), Water Absorption Test (Set of 3 Blocks) etc. complete. 96 Providing and fixing 15 mm dia. CPVC pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. This includes removing the existing pipeline if necessary, conveying, and stacking the same in the PWD chowky or as directed, etc., complete. (Brands such as Astral, finolex, Prince or equivalent make.) 97 Providing and fixing 20 mm dia. CPVC pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. This includes removing the existing pipeline if necessary, conveying, and stacking the same in the PWD chowky or as directed, etc., complete. (Brands such as Astral, finolex, Prince or equivalent make.) 98 Providing and fixing 25 mm dia. CPVC pipe on walls, ceiling, or floor with necessary fittings, and remaking the demolished portion, etc., complete. This includes removing the existing pipeline if necessary, conveying, and stacking the same in the PWD chowky or as directed, etc., complete. (Brands such as Astral, finolex, Prince or equivalent make.) 99 Providing and fixing on walls/ceiling/floor 32mm dia CPVC pipe with necessary fittings, remaking good the demolished portion, etc., complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed, etc., complete. (Brands such as Astral, finolex, Prince or equivalent make.) 100 Providing and fixing 75 mm dia stabilizer pipe/P.V.C. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. 101 Providing and fixing 100 mm dia stabilizer pipe/P.V.C. soil vent/waste pipe with necessary fixtures and fittings, such as bends, tees, single junctions, slotted vent, clamps, etc., complete. (Brands such as Astral, finolex, Prince or equivalent make.) 102 Providing and fixing 10 cm PVC nahani trap with grating, etc., complete. (Brands such as Astral, finolex, Prince or equivalent make.) basic rate for nahani trap is Rs. 380/- 103 Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. basic rate for pillar cock is Rs. 1250/- per number 104 Providing and fixing of Exhaust fan 150mm Crompton/Havels/Usha or equivalent etc. complete. basic rate for exhasut fan is Rs.1000/- per number 105 Providing and fixing Stainless Steel Round Napkin Hanger for Bathroom/Towel Holder for Wash Basin/Napkin Holder/Bathroom (Chrome) B. HeavyMaterial Stainless Steel Product Dimensions 17L x 5W x 19H CentimetersFinish Type ChromeInstallation Type wall-mounted Shape Round including fitting etc. completed.Basic rate for material is Rs. 320/- 106 Providing and fixing Premium Front Glass Shelf - Bathroom Shelf/Kitchen Shelves Wall Mounted With Frosted And Toughen (Tradition 6 X 18) Chrome including fitting etc. complete. Basic rate for material is Rs. 650/- 107 Providing and installation of 6 mm thick mirror with 6 mm thick ply backing, as per design. The mirror will be supported by stainless steel finished buttons, etc., complete. (The glass brand should be Saint-Gobain, Borosil, or an equivalent make) basic rate for mirror is Rs. 1250/- per sq.m. 108 Supply and Installation of NSD MAKE Smoke DetectorModel:66A, Certification: CE & ERTL etc. complete. 109 Supply and Installation of NSD MAKE Heat DetectorModel:66H, Certification: CE & ERTL etc. complete. 110 Supply and Installation of Response Indicator Make: NSDModel: P.S (Mini) etc. complete. 111 Supply and Installation of Manual Call Point (M.S) Make NSD 112 Supply and Installation of 08 Zone Fire Alarm Panel Make NSD(Excel) etc. complete. 113 Supply and Installation of Flasher Hooter make NSDModel No: MS17FLASH etc. complete. 114 Supply and Installation of Supply & Laying 1.0 Sq. mm X 2 Core Copper Armored ISI Cable for alarmsystem. With accessories Per meter. Brand/Make :polycab/Finolex/havellls) etc. complete. 115 Supply and Installation of High quality CO2 Fire Extinguisher (6 kg)Type:Carbon Dioxide (CO2) Fire Extinguisher (For electrical fires and flammable liquids)Capacity: 6 kgFire Rating: Class B (Flammable liquids) Class C (Electrical fires)Material: Cylinder: Steel or Aluminum alloyFinish: Red powder-coated for durabilityOperating Pressure: 55 barDischarge Time: Approx. 8-10 secondsDischarge Range: 3-5 feetTemperature Range:Operating: -10°C to +60°C Storage: -30°C to +60°CMounting: Includes wall bracket Certification: IS 15683 (India) / UL/CE Certified etc. complete.Note: The rates for all Fire Safety Alarm items include the complete supply, installation, commissioning, transportation, freight, and all associated costs. 116 Providing Architectural/ Interior design Services : Scope of Work as below:Drawings Preparation: 3D views, floor plans, furniture layout, electrical layout, ceiling layout, and partition layout.Color Scheme & Material Selection: Guidance on colors and material choices for finishes, flooring, and furniture.Quality Control: Ensure standards for structural, civil, electrical, fire safety, furniture work and HVAC work.Interior Planning: Optimize lab functionality and aesthetics, including furniture, partition design, and system planning (electrical, HVAC, fire safety).Modifications: Suggest changes to designs based on site conditions and client feedback.Coordination & Monitoring: Ensure project progress and timely completion by working closely with contractors. Deputation of Interior designer degree/diploma/certificate course having knowledge of AutoCAD and 3D Home or equivalent for the full period of the work. Designes. Monitor on-site execution, ensuring design adherence. Taking joint measurements.Preparing statements for extra items and excess quantities.Compliance & Safety: Ensure adherence to safety codes and regulations. etc. complete.
Contract Date: Jul 18, 2025 Contract Value : 1.23 Crore
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
29.
Housing Urban and Rular Development #8213090 AOC
Tender For General-Urgent Repair Works To Kanichar Bridge -1-.-General Civil Work - Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metresPrestressed / Reinforced cement concrete grade M-20 & above. - By Manual Means 3 14.7:Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, center to center spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. 4 OD59898/2025-2026:Chipping and spalling / defective concrete and exposing the defective/ corroded reinforcement of the ceiling ,join the additional bar wherever 1/3diameter of thebarr is corroded.Removal of the defective concrete across the bar should be at least 2mm beyond the defective bar so that the reinforcing bar can be cleaned with emery ribbon , wire brush etc.After cleaning the bar wash the bar wash with clean water and collected spalled / fallen concrete .Measurement is calculated for whole exposed area.Including cost of materials,labour charges ,conveyance of materials to site hirecharges of tools etc.complete. 5 OD59897/2025-2026: Anti Corrosive treatment to Steel: Providing & applying inhibition coats/system to exposed reinforcement bars & also new bars, after cleaning & removing scales and rust completely as specified in 1.4, Two component inhibitor Nitozinc Primer std. of Fosroc or MasterEmaco P130 of BASF or equivalent having specific gravity of 1.75 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40 microns DFT per coat as approved by Engineer-in-charge and/or Consultant shall be used as per manufacturer?s specification in two coats at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, necessary surface preparation and necessary protection after and during work. The concrete surface area contianing the rebars where the treatment is carried out shall be considered for measurement. 6 OD59899/2025-2026:Rust remover/ Rust converter: Cleaning of rust /scales/corrosion from reinforcement bars should be carried out uing acid based rust remover, Reebakleens RR of Fosroc or equivalent , or using alkali based rust converters such as Feovert of Krishna Conchem . The material is to be applied to the rustedmatal bar, using brush and living it to dry for 30 Min & washing surface with fresh water as required to exposed reinforcement bar at all heights , including all material , labour tools ,temporary supports for structures , electricity ,plant and machineries complete as per detail specification and as directed by Engineer -in -charge and / or Consultant. The concrete surface area containing the cleaned rebars shal be measured for payment. 7 OD59896/2025-2026:Polymer Modified Mortar (Pre-Packed): Providing and Applying single component,high strength, fibre reinforced, thixotropic cementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1 day and 45 MPa at 28 days and capable of applying upto 50mm thick in single layer such as Renderoc SP40 of Fosroc or Master Emaco S 348 of BASF or equivalent, to the prepared concrete area for thickness up to 50mm, after applying epoxy resin based bonding coat as per manufacturer?s specification, before the bonding agent becomes tack free, initially by hand and finally finishing the same with trowel carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface on the columns, slabs, beam etc. at all heights, where the thickness of application is less than 50 mm in patches as per specification . Item rate is inclusive of all material including the bond coat, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete and as directed by Engineer-in-charge and/or consultant. 8 14.2:Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications 9 55.26a:Providing and applying elastic, elastomeric membrane forming system with anticarbonation and breathing properties. The system should be based on solvent free acrylic polymers with selected mineral fillers and should be ultra-violet resistant, crack bridging type, carbonation resistant, breathable, enviornment friendly, water proofing coating. For anticarbonation, equivalent air layer thickness denoted as R or SD CO2 grater than 50 m and for breathability equivalent air layer thickness denoted as SD H2O shall be less than 4 m for vapour transmitting barrier. The system consists of one coat primer @ 75- 100 g/m2. The consumption of main polymer coating to give film thickness of 200-225 microns (Solid contents- 70%+ -3%) should be approximately. 400-450 g/m2 per two coats depending upon the method of application (either by roller or brush) and surface smoothness of the concrete. The total dry film thickness of the coating system should be minimum 200 microns for the above system. Polymer coating should be in suitable approved shades, including cost of materials, cleaning, chipping and removing the dirt particles of the concrete slab with wire brush and water,labour charges for filling the bug holes, cracks, joints etc with one component polymer modified fine repair and cosmetic mortar, labour for applying the above coating, scaffolding charges,etc. complete as per IRC SP:80 Clause 6.5.1 and Clause 2808 in the Specifications Book for Roads & Bridges published by the Ministry during April 2013.
Contract Date: Nov 06, 2025 Contract Value : 4.28 Lakh
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 3.86 Lakh
Boards / Undertakings / PSU No of Bidders 2
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 10,390
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttarakhand View Result →
32.
Defence #8130927 AOC
Tender For Repairs To Structural Members Using Retrofitting Method In Certain Places Under Ge (N) Bikaner At Bikaner Mil Stn; 1 Demolition of cement conc. Reinforced as in staircase , beamschhajas and similar suspended work reinforced cut required to facilitate demolition complete all as specified and as directed. 2 M&L for RCC Design Mix of M-25 slab supported on walls beam and column in floor roof landing and like using 20 mm graded stone aggregates complete all as specified and as directed. 3 M&L for Form work to soffits of suspended slab such as roof slab not exc 200 mm thick to rough finished surface of concrete complete all as specified and as directed. 4 M&L for Form work to edges of conc flat floor and roofs n exc 20 cm wide to rough finished surface of concrete complete all as specified and as directed. 5 M&L forMild steel TMT bars 10 mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. 6 M&L forMild steel TMT bars 8-10 mm diaas reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. 7 Structural design for Existing Roof Slab, Beams, Chajja, staircase and other connected RCC members required to be re-constructed under this Schedule with & including vetting of structural design & detailed report from approved Govt Engineering College/NITTTR/CBRI, complete all as specified and as directed. Notes : (i) Tenderer shall carryout the site visit to ascertain the size of slab, other RCC members, arrangement of rooms, etc required for design purpose.(ii) Four sets of Structural drawings shall be provided to GE by the contractor duly vetted as above as directed by Engineer in charge. 8 Taking down cement plastering at any description on brick or stone wall etcincluding rakingout joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed complete all as specified. 9 M&L for rendering 15 mm thick in CM 1:6 on concrete solid block wall surfacefinished even and smooth without using extra cement complete all as specified and as directed. 10 M&L for applying two coat of oil bond distemper over a coat of wall care putty on walls after preparation of newly plastered surfaces complete all as specified and as directed. 11 M&L for rendering 15mm thick in 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc in two coatsfirst coat of 10 mm in CM 1:4 & 2nd coat of 5 mm in CM 1:4 mixed with liquid water proofing liquid (ISI marked) @ 200ml/bag of cement or as per manufacturer’s instructions upto 3 storie height, finished even & smooth without using extra cement complete all as specified and as directed. Note :- Supply only water proofing liquid shall be measured and paid separately under relevant items. 12 Supply only integral water proofing liquid complete all as specified and as directed. 13 M&L for preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of cement based paint, white or tinted over a coat of alkali resistant priming paint complete all as specified and as directed. 14 M&L for applying Two or more coats of 100% Premium acrylic emulsion exterior painthaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality] Make o f Exterior Emulsion : Asian: (APEX) / - Berger (WEATHER COAT ANTI DUST) / Nerolac (EXCEL TOTAL) 15 M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & fair without using extra cement complete all as specified and as directed. 16 M&L for preparation of newly plastered surfaces of ceilingand applying three coats of white wash complete all as specified and as directed. 17 M&L for preparation of newly plastered surfaces of ceilingand applying two coats of oil bound distemper complete all as specified and as directed. 18 Dimolition of brick work built in cement mortar including all quions arches pillars etc. complete all as specified and as directed. 19 M&Lfor brick work with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed. 20 Demolition of existing RCC chajja/slab ceilingof any size and description and S&F 25 mm to 30 mm sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stone, templates etc n exc 2m in length , punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 incl plastering all around in CM 1:4 complete all as specified and as directed. 21 M&L for 10 mm thick screed bed in cement mortar 1: 4 onconcrete surfaces, finishedfair & even including mixing water proofing compound as per manufacturers instns complete all as specified and as directed. ( WPC to be measured separately as supply only). 22 Waterproof coating: M&L for providing and applying modified polyurethane hybridelastomeric water proof coating Nito proof 725 or equivalent,for chajjas and walls which is a single component, water-based, lexible and UV stable water proofing compound easy to apply with brush esorrollers. The application includes cleaning the substrate to make it free from any dust, dirt, laitance and other contaminants, followed by priming the surface by mixing the water proofing compound with clean water in 1:1 proportion and applying on the substrate. The water proof coating shall be applied when the primer coat is dry to atackystate, in two seamlesscoats,with adequate inter-coat interval and these condcoating perpendicular direction to the first coat, etc. all complete as per Manufacturersspecifications complete all as specified and as directed. 23 Removal of damaged concrete: Removing, chipping and cleaning of existing loose and damaged concrete carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete or controlled sand blasting including cleaning the surface by air jet complete all as specified and as directed. 24 MS Scaffolding:Supplying, erecting scaffolding upto required height with necessary H-frames pipes, couplers,buckles,bracings,top platform with support railing at top etc. including carriage of the materials to the location, erecting, fixing the scaffolding and dismembering the same afte rworking and taking away the scaffolding materials etc. complete all as specified and as directed. 25 Supports:M&L for providing and erecting MS props to support the structure provisionally during dismantling and repair works and maintaining them in position till required complete all as specified and as directed. 26 Application of rust converter: M&L for Clean all existing reinforcement bars with wire brush / rotary wire brush and apply rust remover solution to make entire surface of bars free from rust scales,loose material,dirt etc. Allow the applied material to react for about16-24 hours, then finishing by thoroughly washing down with clean water and completely drying the bars. The material shall have specific gravity 1.16-1.22@25°C.The application shall be as per Manufacturers specifications complete all as specified and as directed. Make: Reebaklens RR of Fosroc or equivalent. 27 Zinc-rich Anticorrosive coating: M&L for applying two component epoxy based zinc rich primer on the exposed reinforcement bars after the application of rust remover, including, mixing the two components of the zinc rich primer until a homogeneous mixture is obtained. The zinc rich primer shall be applied at 40 microns dry film thicknes sand shall have salt spray resistance of < 5mg for 96 hours as per ASTMB-117 and adhesive bond strength >1.5MPa as per ASTMD4541. It shall have specific gravity >1.5 and total zinc content > 67% in the dry film, etc. All application shall be as per Manufacturers specifications complete all as specified and as directed. Make: Nitozinc Primer of Fosroc or equivalent. 28 Fixing of packers:M&L for Clean the existing surface to remove all dirt, dust, loose materials and other contaminants, Drill holes of suitable diameters upto 20mm at an angle of 45 degree in a staggered manner across the deteriorated / cracked concrete surface, at 300-500mm center-to-center or as per site requirement. Clean the holes with air blowers and Fix NRV metal packers in the cleaned holes with epoxy putty, etc. complete all as specified and as directed. 29 Epoxy injection grouting:M&L for providing and injecting solvent free, two part, high strength epoxy resin based injection grout using pressure injector with accessories till the packers refuses to accept the grout. The application includes mixing of component parts in adequate proportions as per manufacturers instructions and grouting the mixed material in to the structural member through the pre-fixed injection packers by using suitable pressure pump, maintaining desired pressure. Remove the injection packers and seal with any suitable thixotropic epoxy adhesive or repair mortar after the refusal of grouting material from the packers, etc. all complete as per Manufacturers specifications complete all as specified and as directed. Make: Conbextra EP10 of Fosroc or equivalent. 30 Shear key connectors:M&L for providing and fixing shear connectors-8mmdia. or as specified Highyield steel rebars of specified length on the prepared concrete substrate, including drilling holes of suitable diameter sinstaggered manner across the concrete surface and fixing the shear connector bars in to the holes with chemical anchor grout Lokfix E77 or equivalent, etc. all complete as per site requirements complete all as specified and as directed. 31 Epoxy bond coat:M&L for providing and applying high strength solvent-free epoxy resin based bonding agent for effective bonding of the new repair material to the existing concrete, including mixing of the two components-base and hardener thoroughly until a homogeneous mixture is obtained, applying with soft bristlenylonbrush on the prepared substrate where new concrete or mortar is to be placed, ensuring that the bond coat is in tacky state while placing the repair material, etc. complete all as specified and as directed. Make: Nitobond EP of Fosroc or equivalent. 32 M&L for Formwork/Shuttering providingand fixing leak proof shuttering, incl centering, shuttering, proping etc complete all as per site requirement complete all as specified and as directed. 33 Microconcrete jacketing:M&L for providing and laying high strength, non-shrink cementitious microconcrete for repairing and building up broken deteriorated concrete sections. The ready touse blend of dry powder sand selected aggregates, when mixed with clean wateronsite, produces free- flowingn on-shrink repair microconcrete. The application procedure includes mixing the dry powder contents from the bag of ready-to-mix microconcrete with adequate quantity of water as per Manufacturers recmmendations, mixing continuously with high torquerotary drill fitted with mixing paddle, until smooth, even consisteny is achieved, and then placing the mixed material immediately in leak-proof form works, curing after removal of shuttering, etc. all as per manufacturers specifications complete all as specified and as directed. Make: Renderoc RG of Fosroc or equivalent. 34 Note :-(i)The work against serial items 01 to 09, 11, 12, 15, 20 to 33 of BOQfor the structural rapair and strengthening and rehabilitation and roof treatment shall be executed by the company’s authorized applicator firm only.(ii) Contractor have to get prior approval of applicator or authorized agency by submitting its authorization letter to this office for approval prior to commencement of work. Department will conduct an official varification from manufacturer of its authorised agency and provide authorise supervisor from authorise agency for complete execution of spl work. (iii) Contractor shall submit 10 year warranty certificate for structural repair and 10 year warranty for roof waterproofing treatment work over roof is mandatory after completion of work. (iv) The cost of Scaffolding work required at certain places is including in the respective items catered for repairs itself. No extra shall be paid for the same.
Contract Date: Oct 18, 2025 Contract Value : 70.18 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
33.
Railways #8097392 AOC
Annual Maintenance Contract (Amc) For Civil Work From Mundka (Excluding) To Brig. Hoshiyar Singh Dead End For Three Years.; NDSR-1 Polycarbonate sheet: Providing and fixing of leak proof fire resistance and UV resistance at all height of lexan compact clear sheet of 5mm thick GE plastic or approved equivalent make confirming to IS14443-1987 the rate is inclusive of cost of fasteners silicon sealant, EPDM gasket and any other fittings as required for completion of work as per Engineer in charge. NDSR-2 Providing and fixing 12 mm thick laminated glass consisting of 6.0 mm thick (+ or -0.3) thick clear toughened glass on both faces having 1.52 PVB layer in between including provision of EPDM gasket performed all spacers, desiccants, silicon sealants etc. as per manufactures specifications , drawings & directions of engineer in charge (area of glass unit outside the snap beading shall be measured). NDSR-3 Providing hardware or other parts for smooth functioning of rolling shutter. Items will be supplied as per CPWD specifications. NDSR-3a Brackets(Sides). NDSR-3b Wire Spring NDSR-3c Spring Holder. NDSR-3d MS-Gararee device. NDSR-3e Gear Box. NDSR-3f Rolling Shutter Handle. NDSR-3g Locking Naka/kundee including welding. NDSR-3h Ball Bearing NDSR-3i Gararee Rod. NDSR-3j MS-Top Cover. NDSR-3k Bottom Locking rail NDSR-3l M.S.Laths NDSR-3m MS Pipe shaft 2 dia NDSR-3n Side guide Rail. NDSR-3o Rolling Shutter lever lock NDSR-4 Supply of sky lift on hire charges basis 20 mtr long boom for 8 hours (per day) including operators, all arrangement of safety,barricades,Traffic marshal etc.all complete as per direction of engineer-in-charge. NDSR-5 Providing and fixing of hilti frame anchor fasteners HRD-C-2 10x160 including making & cleaning hole in concrete/granite and using all T&P etc. Complete or as per direction of engineer in charge. NDSR-6 Providing and fixing 6mm thick toughened glass in existing frames, sub frames with EPDM rubber gasket, silicon sealant and necessary pressure clip as and where required. The rate quoted shall be inclusive of fixing and grinding corners and required holes etc. all complete and all taxes etc. The contractor shall visit the site and take exact measurement of size in which glass is to be provided at various locations. NDSR-7 Providing,cutting and fixing Hilti Chemical fastener using threaded Hilti Rod AM 12x3000 of grade 8.8 Zinced and fixing with HILTI Chemical grout RE 500 V3 including cutting the rod to required length of 160mm, providing necessary nut, washer, drilling of hole in RCC, Concrete or brick masonary, cleaning the hole with blow out pump, fixing the fastene with chemical grout using chemical injecting gun etc. complete as per direction of Engineer-in-charge. Payment shall be made for each bolt of 160mm length with one nut and washer all complete. (Work during block hours in night) Rates are inclusive of GST and Carriage. NDSR-8 Providing and fixing Hilti Chemical fastener HIT-V-5.8, M12x220mm of 12mm dia including injecting HIT-RE 500 V3 chemical grout using injection gun including drilling of hole in RCC, concrete or brick masonry, cleaning the hole with pump, fixing the fastener, injecting the chemical etc. as per direction of Engineer-in-Charge (Work during block hours in night0 rates are inclusive of GST and Carraige. NDSR-9 Providing and fixing Hilti Chemical fastener HIT-V-5.8, M16x260mm of 16mm dia including injecting HIT-RE 500 V3 chemical grout using injection gun including drilling of hole in RCC, concrete or brick masonry, cleaning the hole with pump, fixing the fastener, injecting the chemical etc. as per direction of Engineer-in-Charge (Work during block hours in night0 rates are inclusive of GST and Carraige. NDSR-10 Providing and fixing CPVC union in CPVC pipe (Astral/Ashirwad) including cutting and threading the pipe making long screw etc. complete. NDSR-10a 15mm nominal bore NDSR-10b 20mm nominal bore NDSR-10c 25mm nominal bore NDSR-10d 32mm nominal bore NDSR-10e 40mm nominal bore NDSR-10f 50mm nominal bore NDSR-11 Providing and fixing CPVC ball valve (Astral/Ashirwad) in CPVC pipe including cutting and threading the pipe making long screw etc. complete. NDSR-11a 20mm nominal bore NDSR-11b 25mm nominal bore NDSR-11c 32mm nominal bore NDSR-11d 40mm nominal bore NDSR-11e 50mm nominal bore NDSR-12 Providing and fixing CPVC male Adaptor brass threaded (MTA) of approved quality: NDSR-12a 20mm nominal bore NDSR-12b 25mm nominal bore NDSR-12c 32mm nominal bore NDSR-12d 40mm nominal bore NDSR-12e 50mm nominal bore NDSR-13 Providing and fixing of bulk type water meter Class B Flanged type with CI body with dry Dial type & Magnetic Drive make KRANTI or equivelent conforming to IS 2373. The rates include all cost of material , labour, Transportation, tool & plants, all height, Taxes etc as per direction of Engineer in Charge of size: NDSR-13a 50mm NDSR-13b 65mm NDSR-14 Providing and fixing C.I. dirt box strainer for bulk type dry dial and magnetic drive water meter with nuts, bolts, rubber insertions etc. The rates include all cost of material, labour, transportation, tool & plants, all height, Taxes etc as per direction of Engineer in Charge of Size: NDSR-14a 50mm NDSR-14b 65mm NDSR-15 Providing and fixing PVC P-trap/multi-trap/Nahani-trap of 110mm dia. for kitchen/bathroom with demolishing of kota stone/cement concrete flooring of required area or up to 1.0 sqm for rectification of seepages and repairing the same as above, including the cost of materials i.e. PVC P-trap/multi-trap/Nahani trap, solvent, piece of PVC pipe, Kota stone, cement concrete or other materials, labour charges, taxes etc. complete as per direction of Engineer-in-charge. NDSR-16 Providing and fixing UPVC/CPVC Female brass thread Tee (FBT Tee) of approved quality :15mm nominal bore NDSR-17 Providing and fixing UPVC/CPVC Female brass thread Elbow (FBT Elbow) of approved quality :15mm nominal bore NDSR-18 Providing and fixing of high pressure laminated board confirming to code BS EN-438-2015 of 12mm thickness for partition and doors with all necessary fittings, fastners, screws and rubber strip for the groove in the pilaster for reducing noice level of door closing etc required as per approve design and colour and direction of engineer incharge. NDSR-19 Reparing of door by taking out of the door and refixing and the same after the sawing ,screwing,nailing as required to repair and free movement of door. NDSR-20 Extra for painting work above 6.0meter height for each coat of priming/painting work NDSR-22 Providing and fixing pillar mixture tap on wash basin (Make of Volga, Marc, Parko or approved quality) NDSR-23 Providing and fixing mixture tap on kitchen sink (made of Volga, Marc, Parko or approved quality) NDSR-24 Providing and applying two coats of Unitiles Rodeo or spectrum perlina fine or Heritage Granula Surface Texture paint, after applying corresponding roller coat as primer on pre-plastered surface as per approved sample in approved shade. The composition of texture paint should consist of Acrylic copolymer resins combined with quartz, silica, mineral aggregate, synthetic inorganic pigments, bactericide, fungicides and various other additives giving the product water repellant properties. The first coat to be applied by brush or wool roller as a base coat diluted with sufficient water and the final coat (Undiluted) to be applied by trowel and finished with Acrylic trowel to maintain with or without groves, as per details in drawings. The thickness of both coats should be 1.0 to 1.5mm .the water repellency of the product shall be >= 86gm/m2 as per test method IS:5410-1969, complete as per manufacture s specifications and instructions by Engineer in charge at Site .The rate shall include necessary scaffolding, labour and material complete. NDSR-25 Providing and fixing 2 mm thick textures, ultra violet quoted polycarbonate sheeting in required shape as per existing profile in roofing above platform level at line-5 stations laxane make or equivalent including all tools, materials, labours, safety equipments etc. all complete as per direction of engineer in charge. (make - as per approved list) NDSR-26 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 6 kg /cm^2) conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. NDSR-26a 160 mm Diameter NDSR-26b 200 mm Diameter NDSR-27 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. NDSR-27a 200 mm x 100 mm Dia. Reducer Tee NDSR-27b 200 mm x 200 mm Dia. Bend NDSR-28 Providing & Fixing CONCEALED CISTERN BODY (Make Jaquar JCSWHT-2400)MATERIAL NDSR-29 Providing & Fixing Urinal-Flat Back Half (make Hindware Cat.no.60010) NDSR-30 Providing & Fixing URINAL VALVE AUTO CLOSING SYSTEM WITH BULTIN CONTROL COCK & WALL FLANGE WITH FLOW RESTRICTOR 1.5 LPM AT 3 BAR PRESSURE (Make Jaquar PRSCHR-077G*) NDSR-31 Providing & Fixing Wash Basin-Oval Under-Counter (Make Jaquar CNS-WHT-705) NDSR-32 Providing & Fixing Wash Basin-Anugular Stop Cock (Make Jaquar Con-059KN NDSR-33 Removing of poster/banner from metro pier by scrapping by wire brush or by any other mean upto height of 3 m NDSR-34 Providing & Fixing Pillar Angle Valve- Angular Stop Cock with Fall Flange (Make Jaquar OPP-15053PM) NDSR-35 Providing & Fixing Pillar Clock- PILLAR COCK AUTO CLOSING SYSTEM WITH FLOW RESTRICTOR OF 1.3 LPM AT 3 BAR PRESSURE ( Make Jaquar PRSCHR-031GE) NDSR-36 Providing & Fixing PVC Connection- Braided Hose ( Make Jaquar ALD-805B) NDSR-37 Providing & Fixing Waste Coupling - fully threaded, 32 mm dia ( Make Jaquar ALD-705) NDSR-38 Providing & Fixing Curved shaped urinal partition with frosted glass (Make JAQUAR JSE-CHR-810UC450X NDSR-39 Apply rust converter to steel reinforcement to protect against further corrosion. NDSR-40 Providing and erecting the safety net of opening 75mm*75mm size at first floor level to prevent the debris falling on ground during progress of work and keeping the same in position during the entire period of work .(One time payment shall be made for providing net from start of work till completion of work including shifting if any. The Scaffolding net shall be the property of the DMRC on completionof the work). NDSR-41 Supply of Micro concrecte chemical in 25 kg bag and applying at site as per manufacturere specification and direction of Engineer in Charge. NDSR-42 Providing and using single component cement based non-shrink micro concrete of approved manufacture by mixing graded stone aggregate 10 mm and down and coarse sand as per manufacturers specification & direction of Engineer-in-charge complete as per design and approved by Engineer-in-charge complete as per design and approved by Engineer-in-charge at all floor and all heights NDSR-43 Providing, mixing and applying Epoxy Repair Mortar of make FOSROC or SIKA or BASF or equivalent by mixing Resins hardner and filler as per manufacturers specifications and directions of Engineer-in-charge for providing covers to reinforcement etc. as per site requirement. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and quantity for different thicknessshall be made proportionally under this item+B10. Payment under this item shall be made only after proper curing has been done as per manufacturers requirement and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. Scaffolding or skylift for work at height shall be paid additionally in relevant items. 12 mm thickness NDSR-44 Sealing of crack width: Cutting V groove of different size for sealing along the cracks. Cleaning the groove with brushes and cleaning holes with blow air, Fixing self locking mechanical packers into the grooves with epoxy mortar consisting of conbextra EP- 10/Sikadur31 or equivalent and silica sand and powder. NDSR-45 Providing safety and traffic diversion arrangement at the location of work with two stage protection that is with Concrete barriers and PVC drum filled with Sand/Water. The item shall include transportation and placing in position of concrete barriers (06 nos. concrete barriers of size 2.5-3m (length) and 1.2 m height) and suitable nos. of drums as per approved plan and direction of Engineer-in-charge. The concrete barriers will be provided by DMRC (which will be required to be lifted by contractor from any DMRC site within NCR), whereas all other materials are to be provided by contractor. The item shall include all labour/material cost for filling of drums, providing reflective lights, reflective tapes, caution tapes, 02 nos. marshals for traffic diversion and any other miscellaneous item(s). The marshals shall remain available from the start of work at the location, till the location is cleared completely of all men and material. On completion of work, concrete barriers will have to be returned to DMRC and placed as per directed location. Nothing shall be paid extra for all the works described in this item. NDSR-46 Providing and injection Dr. Fixit PU Foam Injection two component polyurethene form injection grout manufacture by Pidilite Industry Ltd and to be sile mixed in ratio 10:1(10 part base I part hardener / or equivalent. that shall be injectectd with maechanically piston driven pump with maximum pressure uplo 250 bar or Foam shall be based on MDI)Methylene Diphenyl isocyanate) polyurethene pre-polymer and accelator. The system shall reacts when it comes in contact with water, producing a relatively stiff and insert polyurethane foam. It is a 10% solid and solvent free polyurethane grout for quick temerary closing and sealing of water bearing cracks, cavities and leak under hydrostatic pressure. The systems shall be foams to 30-40 times its volue in the presence of water and can be an effective means of arresting running water and seepage. It includes the cost of PU lubricant also.Rate Inclusive of all taxes. NDSR-47 Providing and Injecting Dr. fixit or forsec PU plain injection, two component polyurethene plain injection grout manufactured and to be sile mixed in ration 2:1 (2 part base 1 part hardener )/ that shall be injected with mechanically piston driven pump with maximum pressure upto 250 bar or as per the requirement of the site at a distance of 300mm C/C in all direction. The PU plain shall be low viscosity, high penetration quick setting and should forms tough and flexible polyurethene rubber after complete chemical reaction with or without water. It includes the cost of PU lubricant. Rate inclusive all of providing, fixing, cutting of non return packers of required size and repairing the surface with polymer mortar complete at all heights NDSR-48 Providing and applying the areas over the welded wire mesh with Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar - product-Renderoc SP 40 / Renderoc HS Extra or equivalent and upto required depth to level the surface upto 25mm. All work shall be carried out completly as per direction of Engineer-in-charge. NDSR-49 Providing and applying the area with Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar. Suggested product-Renderoc SP 40 / Renderoc HS Extra or equivalent by trowel minimum15 mm as cover to reinforcement steel. All work shall be carried out completly as per direction of Engineer-in-charge. NDSR-50 Supplying and Installation as Specified the following as per direction of Engineer-in-charge, including all taxes and dues applicable a Water type check valve 100mm dia of Odco, sant, kirloskar or equivalent make confirming to PN-10. b Pressure gauge with isolating valve of 10mm dia confirming to IS 3624 of H-Guru, Dan-Fuss or equivalent makes NDSR-51 Supply of submersible pump set with 4 HP, 3 phase, 440 volt, 50 Hz motor 10 stage pump suitable for 80 feet water level and discharge 1800 ltr/hr modele no. CORA- 12C/) make - KSB including anti falling GI wire for holding the borewell motor into the existing borewell. NDSR-52 Supply erection of 2.5 sqmm submersible cable make- Finolex, CCI, skyone The rates are inclusive of all taxes and duties complete. NDSR-53 Supply, erection, testing and commissioning of electrical panal made of 114/16 SWG CRC sheet duly wired up along with the following items The rates are inclusive of all taxes and duties complete. a Ammeter b Voltmeter c Single phase preventer d DOL starter e MCB f On/Off push botton g On/Off indication lamps h Timer i Solonid valve NDSR-54 Lowering of pump submersible into the existing bore as per direction of Engineer in charge . The rates are inclusive of all taxes and duties complete. NDSR-55 Providing and fixing ISI mark 4 x 2.5 sqmm. Copper conductor armoured cable. All work shall be carried out as per direction from Engineer-in-charge. The rates are inclusive of all taxes and duties complete. NDSR-57 Providing & fixing of bulk water meter Class B flanged type with CI body with dry dial type & Magnetic drive make Kranti or equivilant conferming to IS:2373. The rate include all cost of material, labour , transportation, tools & plant , all height , Taxes etc as per direction engineer in charged a 40mm b 50mm c 65mm NDSR-58 Miscellaneous civil works like cleaning of ground rain water, meshes, minor repairing of drains, meshes, manhole covers etc. The rates are inclusive of all taxes and duties complete. NDSR-59 Lifting of pump set from the existing bore as per direction of Engineer in charge . The rates are inclusive of all taxes and duties complete. NDSR-60 Providing and operating disel boom lift for 25-28 m reach. Rate shall included disel charges, one operator with all safety items, including loading/unloading of lift a site, traffic marshal and safety equipments. Rate is excluding of GST but including all other applicable charges NDSR-61 Cleaning/desilting of platform saucer drain by removing of saucer drain cover and refixing of same after cleaning work NDSR-62 Reviving of RWH pit upto 1 cubic meter capacity by replacing old filter media with new one . This item has rate inclusive of clearing choking of embeded PVC slotted pipe and safety of work site by deploying traffic cones, PVC drums, Traffic marshal etc. NDSR-63 Reviving of RWH pit upto 1 cubic meter capacity by cleaning/screening old filter media. This item has rate inclusive of clearing choking of embeded PVC slotted pipe and safety of work site by deploying traffic cones, PVC drums, Traffic marshal etc. NDSR-64 Reviving of RWH pit upto 10 cubic meter capacity by replacing old filter media with new one . This item has rate inclusive of clearing choking of embeded PVC slotted pipe & Cleaning of de-silting chamber for RWH pit NDSR-65 Reviving of RWH pit upto 10 cubic meter capacity by cleaning/screening old filter media. This item has rate inclusive of clearing choking of embeded PVC slotted pipe & Cleaning of de-silting chamber for RWH pit NDSR-66 Reviving of RWH pit upto 20 cubic meter capacity by replacing old filter media with new one . This item has rate inclusive of clearing choking of embeded PVC slotted pipe & Cleaning of de-silting chamber for RWH pit NDSR-67 Reviving of RWH pit upto 20 cubic meter capacity by cleaning/screening old filter media. This item has rate inclusive of clearing choking of embeded PVC slotted pipe & Cleaning of de-silting chamber for RWH pit; NDSR-70 Providing Welder/Fitter for welding work along with welding machine to carry out welding as per the directions of Engineer-in-charge including cost of tools, safety equipements,consumable (electrodes) etc. NDSR-71 Providing Plumber/Carpenter/Mason for plumbing /sewerage/Carpentry/masonary work, rectification works with all required T&P as per directions of Engineer in Charge NDSR-72 Providing Helper/beldar for miscellaneous civil works with all required T&P as per the directions of engineer in charge.
Contract Date: Oct 13, 2025 Contract Value : 3.38 Crore
Boards / Undertakings / PSU No of Bidders 4
35.
Defence #8084797 AOC
Tender For Addn/Altn To Airmen Mess At Af Stn Bikaner; 1 Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for completeall as specified and directed 2 Demolition of mud in roofs, any thickness including plastering & leaping (wheather full or part)removal of debris at a distance exc 250m but not exc 500m and deposited where directed 3 Materialand labourfor providingcementconcrete PCC (1:2:4) type B1 (20mm graded crushed stone aggregate)as in roofpaddingcompleteall as specified and directed 4 M&LforAPPbasedmodifiedpre fabricatedfivelayer3 mm thick andweighingnotlessthan3.0 Kg/Sqmwater proofing membrane reinforcedwithpolyesternon wovenfabricmatwith150 gm/Sqm blackfinishedwith compatibleprimerconformingto IS 3488 @ 0.30 Lit/ Sqm andbonding material85/25bitumen1.2 Kg/Sqmbefore layingmembranelaidbytorchapplicationsideoverlapof 75 mm andoverlapof 100 mm longtitudinally, At thejunctionof roof andparapet walla groveof 20 x 20mmshall be madeatthehtof100 mmandmembrane shall be inserted andsealedwithbituminious masticjoints/overlap shallve saledwithhotbitumen85/25all as directedby Engineer -in- charge. 5 Supply only integral water proofing compound ISI marked.all as directedby Engineer -in- charge. 6 Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of grooves with cement mortar 1:3 all as directedby Engineer -in- charge. 7 M&L for 15 mm thick plaster in CM(1:4) over concrete surfaces of roofs finished even and smooth using extra cement with WPC @ 3% by weight of cement, complete all as specified and as directed.Note:WPC will be measured and paid seperately. 8 M&L for Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and no pigments in floors, and cut and polished including 15mm thick screed bed in CM(1:6) ,complete all as specified . 9 M&L for Providing cement concrete 1:2:4 type B0 (12.5 mm graded crushed stone aggregate ) in roof kerbs or mud stops, rounded or chamfered on edges complete all as spd 10 Demolition of reinforced cement Concreteof any description and in any position not otherwise specifically provided for completeall as specified and directed 11 M&L mild steel TMT Bars 10mm dia andover cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (annealed not less that 0.90 mm dia or securing with chip) complete all as specified and directed. 12 M&Lfor RCC type B01;2:4( 12.5 mm gradedcrushed stoneaggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and including form work complete all as specified & directed. Note : reinforcement shall be measeured and paid seperatly. 13 M&Lforbrickwork with sub classBbrickold size burnt clay straightor curvedonplan exc6 m mean radiusand builtin cement mortar (1:6), complete all as specified and as directed. 14 Demolition of brick or stone masonary built in cement mortar incl all quoins, arches, pillar etc. complete all as specified & directed. 15 M & Lfor machine cut Granite slab 15 mm thick fixedfor steps, pillars,window cills, cooking plateforms and like and incl 10mm thick (avg thickness) cement mortar 1:4 screeding and setting coat in cement morter 1:2, 3mm thick, set and jointed with white/coloured cement to match the shade of slab incl cutting, waste, rubbing and polshingetc complete all as spd.Note:- (i) The rate of granite stone shall be deemed to incl for full rounded off corner/edges incl all cutting to make it square or rectangular. (ii) The rate shall also be deemed to incl for cutting and polishing machine and granite polishing to achive the desired granite finish all as spfd. 16 Supply& fixingas in repair vitreous china wash hand basin, white flat back, size 300mm x 450mm including pillar tap 15mm diachromium plated with capstan head with long screwed shanks and fly nuts, and including brass, chromium plated,waste coupling 32mm dia, complete all as specified & directed. 17 Supply and Fixed-in-repair, sinks with drainage board made of stainless steel 1 mm thick, kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x160mm, complete all as specified and directed. 18 S&F 40mm bore dia of discharge pipeBottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260gms/40mm-270gms) complete as specified and directed 19 Dismantling water tanks and removing from site of anycapacity complete all as specified and directed. 20 S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top having screwd down LID cover)tripple layerhoisted and fixed in position, complete all as specified and directed 21 S&F 1000 ltr Rotational moulded polythlyene water storage tanks tripple layer (cylindrical vertical having screwd down LID cover) with close top hoisted and fixed in position, complete all as specified and as directed. 22 Supply and fixing in repairs, fancy type angle stop valve, brass, chromium plated,screwed down, high pressure with quarter turn, screwed for iron pipe or for union, suitable for 15mm bore pipe,complete all as specified and directed. 23 Supply and fixingin repairs long body Bib taps,chromium plated cast copper alloy with quarter turn, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for 15mm bore pipe complete all as specified and directed. 24 M & L for Cutting chases, pining in making good to facings where required & pointing in cement mortar1:3 to ends etc or edges of landings, steps cills,sunshades, shelves,lintels,etc and cutting chases for concealed water tubing and making good,cutting n.exc. 10cm girth in brick walls all asdirected. 25 Taking up or down 15 mm dia steel tubing and connectionand removal from site complete all as specified and directed. 26 Taking up or down 20 mm dia steel tubing and connectionand removal from site complete all as specified and directed. 27 Supply and fixing 15mm bore tubes medium grade galvanized with and incl all fittings complete to walls and ceiling with necessary clamps or laid in floors complete all as specified & directed. 28 Supply and fixing 20mm bore tubes medium grade galvanized with and incl all fittings complete to walls and ceiling with necessary clamps or laid in floors complete all as spd & directed. 29 Supply& fixingPVC connections 15mm size with PTMT nuts of length 450 mmcomplete all as specified anddirected. 30 Supply and fixing as in repair vitreous china squatting pan Orissa pattern size 580 x 440mm, white, with integral footrest (excluding flushing cistern) including connection to trap,and to flushing pipe, anti-syphonage pipe,etc. complete including making good to floor, set with cement concrete,complete all as specified and directed. 31 Supply and fixing as in repair PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC bend for required squat pattern etc, set with concrete and making good to floor, complete all as specified & directed. 32 S&Fas in repairs Chromium plated shower roses 125 mm size fixed with swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed. 33 S&F as in repairs 100 mm dia mild steel chromium plated grating with or without waste pipe hole as per requirementcomplete all as specified and directed. 34 S&F in repair tubular towel Rail 600 mm length and20 mm dia of brass chromium plated complete all as specified and directed. 35 S&F in repair stailess steel curtain road 30mm dia of brass chromium plated incl necessary fixing brackets and ornamental fittings , complete all as specified and as directed. 36 S&F in repair soap dish chromiume plated,any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed. 37 Taking down shutters of any description exc 1 sqm but n.exc 2 sqm from chowkhat and removing to or from store as required, complete all as specified. 38 Supplying & fixing in opening solid PVC door frame of size 50mm x 47mm made out 5mm plain colour PVC sheets re-inforced with MS tube Square tube in opening complete all as specified & directed 39 M&L factory made solid panel pvc door shutter 30mm thickconsisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottam rail . paneling of plain colour PVC sheets to be filted in MSframe welded, sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with the solvent cement complete all as spd. 40 S & F 40mm dia cupboard fancy handle fixed with nut screw and washer of mild steel bright finished 41 S & F 40mm width of flaps continuous (piano) hinges mild steel bright finish or electrogalvanised. 42 S&F anodised aluminiumpowder coating aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified 43 S&F anodised aluminiumPowder coatingwindow and ventilator shutters, side hung type without sash bars aluminium section weighing not less tha 0.55Kg/m (with style and rail of size 47.62 x 44.45 x 1.67mm)including necessary joining cleats, glazing clips, ruber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150mm long (1no), hinges type B-21 100mm long(2 no.) suitable handle(1 no) including all necessary builders hardare complete all as specified. 44 Taking down chowkhats with shutter without taking off shutters from the frames (area exc. 1.50 sqm but n. exc. 4.00 sqm each) incl making good the disturbed surfaces complete all as specified & directed. 45 Material & Labour for pressed steel frames with 1.25 mm thick sheet for doors of size 125 x 60 mm for doors with one or more rebate incl necessary fixing lugs, hinges, lock, strike plates of 50 x 3mmwelded with frame and making arrangement for fixing of door spring etc.complete all as specified. 46 Supply and fixing plain, framed, Plain framed, panelled shutter (two panel) 35 mm thick of 2nd class hardwood rail and stylewith lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one coat of pink primer complete all as specified & directed. 47 Supply and fixing glazed and gauged skeleton shutters35mm thick, 2nd class hard wood Hollockopen rebated and prepared to receive glass, gauge etc (with sash bars) edges of framing plain chamfered or rounded fitted with cutand mitred beads for securing glass etcincl priming coat. The size of member of shutters as spfd in SSR Part-1 Section 8 clause 8.24 (a) incl kiln seasoned and chemically pressure treated, complete all as specified & directed. 48 Material & Labour barrel tower bolts aluminium anodised extruded section of size 200 mm complete all as specified & directed. 49 Supply and fixing aluminium fabricated type extruded handles of size 150mm complete all as specified & directed. 50 S&F as in repairs of 300mm mild steel ordinary rat tail rod pattern door spring incl roller and roller plate complete all as spfd. 51 Supply and fixing 300 mm long aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing cleap of sheet, cast or extruded sections, bolt not less then 12mm dia with and including a minimum of 6 bolt and nuts ,fixed on plate or staple plate complete all as specified & directed. 52 Supply and fixing Galvanised mild steel wire cloth, in new doors and windows 0.56mmnominal dia of wire and avrg widh of aperature 1.18mm incl fixing to wooden/steel frames with tinned tacks or galvanised wire or wooden bead complete all as specified & directed. 53 Supply and fixing in repairs, Galvanised mild steel wire cloth, 0.56mmnominal dia of wire and avrg widh of aperature 1.18mm incl fixing to wooden/steel frames with tinned tacks or galvanised wire or wooden bead complete all as specified & directed. 54 Hacking out old broken glass (any th size, quality or description) from wooden or steel frames glazed with putty or fixed with wooden beads complete all as directed. 55 S&F sheet glass 4mm thick ordinary quality and glazing with oil putty or with clip in squares n.ex.c. 0.50sqm in each pane complete 56 All as per Item No. 56 above but 4mm thick ordinary sheet glass exc 0.5sqm in each pane. 57 Materialand Labour for preparation of newsurfaces of wood & wood based surfaceof any description not otherwise described, over 10 cm width & girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and directed by Engineer-in-Charge. 58 Materialand Labourfor preparation of newsteel & steel based surfaceof any description not otherwise described, over 10 cm width & girth and applying twocoat of synthetic enamel paint over and including a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. 59 M&L preparation of old painted steel surfacesof any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) incl for angle iron,fencing post,Rolling shutter etc,complete all as specified & directed. 60 M&L preparation of old paintedwood or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified & directed. 61 Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removal complete all as specified and directed. 62 M&L for non skid ceramic coloured tiles 7-8 mm thick, (square/rectangular) area of each tile exc. 0.11 but n.exc. 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in CM 1:6, complete all as specified and as directed. 63 M & L for joint free glazed coloured ceramic coloured tiles of 300mm x 450mm x 7mm thick on vertical surface of walls set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles, over and including 10mm thick rendering in CM 1:4, all as specified and directed by engr-in charge. 64 M & L for 50 mm thick cement concrete type C-2 1:2:4 (20mm graded crushed stone aggregate) as in sub-base for tilingor similar works, complete all as specified and as directed. 65 M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick screed bed in CM(1:6) laid and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete all as specified & directed 66 Taking down cement plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubing down with water etc complete all as specified and as directed. 67 M&L rendering 15mm in cement mortar 1:4 on fair faces of brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. 68 Material and labourrendering 15 mm in cement mortar 1:6 on fair faces of brickor concrete surfaces and finishing the surfaceseven and smooth without using extra cement complete all as specified and directed. 69 M&L rendering 5 mm in cement mortar 1:3 on fair faces of brick /concrete surface of ceilling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. 70 M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of alkali resistant primer complete all as specified and directed. 71 M&L preparation of newly plastered surfaces of walls including all cornices, pilasters etc and applying two coats of acrylic exterior emulsion paint in camouflage pattern of approved tint / shade(s) over and including a coat ofwater based primer, complete all as specified and directed. 72 M&L preparation of newly plastered surfaces of ceilling / chajja or similar suspended work and applyingtwo coats of white wash complete all as specified and directed. 73 M&L for gunniting work to RCC work in column, flooring, side walls, beam, slab, etc by carefully chipping , removing existing loose/damaged concrete cover etc, and cleaning all exhisting reinforcement bars with wire brush and applying alkaline rust converter primer on exhisting rebars and allowing it to react with rust for 06 hrs and form corrision resistant layer , then applying zinc rich anti-corrosive protective coating on reinforcement bars as per manufacture instructions , and fixing welded wire mesh fabric size 50X50 mm with 3mm dia , and plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 25 mm and making the surface even including 15mm thick plastering in CM 1:4 onconcrete surfaces , finishing the surfaces even and smooth, without using extra cement including necessary form work to be carried out complete all as specified and directed.Note.- Where ever reinforcement/MS steel required will be measuredseparately. 74 Supply & fixing hard drawn MS steel wiremesh 80mm x 25mm with 3mm dia wire with Heavy duty nails, Fixing the mesh on the ceiling before gunniting work. 75 Materail and Labour for preparation of plastered or unplastered old surfaces of ceilingand one coat of white wash on ceiling all as specified and as directed by Engr-in-Charge. 76 M&L for3mm thick wall care putty on wall complete all spd and directed 77 M&L for3mm thick wall care putty on ceiling complete all spd and directed 78 Materail and Labour for Complete removal of existingplastered or unplastered old surfaces of walls and applying two coats of oil bound distemper on walls over and including a coat ofalkali resistant priming paint primer,all as specified and as directed by Engr-in-Charge. 79 Demolition of plain cement concrete in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified & directed. 80 Material & Labour for 75mm thick cement concrete type D-2,1:4:8 (40mm graded crushedstone aggt) as in sub base concrete all as specified & directed. 81 M&L PCC (1:3:6) type C-2, using 40mm graded stone aggregate as in plinth protection 75mm thick laid in baysand surfaces finished even & smooth without using extra cement complete all as specified . 82 Takingdownrain water pipes PVC/AC (anysizeor pattern)includingall fitting heads, shoes, bendsswan -necks etc comlete all as sd and directed by EngrinCharge 83 S&F110mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall including clamps as required, complete all as specified. 84 S&F as 110mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified. 85 S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps as required, fixedcomplete all as specified. 86 S&F 75mm dia PVC (SWR) vent cowl, single, equal or un equal of any length including jointing with solvant cement as required complete all as specified. 87 S&F 75mm dia PVC (SWR) bends with rubber ring joints fixed as required complete all as specified. 88 Material & Labour Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified. 89 M&L for steel work in tubular pipes as in vertical surfaces including special shaped washer such as column complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified 90 M&L for rolled section as in main and cross beam , hip and jack rafters; purlins where connected to common rafters and running rails andm guides for sliding doors fixed with angle cleats or other connecting plates in Fe 290 Gde E-165 complete all as specified 91 M&L Mild steel screw bolt (machine made) dia 11 to 15 mmwith hexagonal or square head at one end and screwed the other or screewd both ends each screwed end to be fitted with washers and one hexagonal nut length of bolt exc 5 cm but n. exc 10 cm long complete all as specified 92 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 93 Dewatering of septic tank/Soakage well, any size any depth, cleaning and taking out effluent water from septic tank by mechanical means as in foul conditions and confined places, filled in closed containers of capacity 5000 Litre each to the full capacity and disposed offat dumping site outside MoD, authorised by Local Administration complete all as specified and directed.Note: Record of disposal of effluent water shall be maintained by the contractor in a pucca bound register. Entry for each trip disposing off the effluent water in container with tractor RC Number carrying the container shall be made in the register and each shall be signed by the Engineer-in-Charge. 94 Desilting of manhole complete by removing all scum, sludge, silt (both organic and inorganic nature) by manual labournor mechanical scraper and disposal of the same and buried in trenches etc, as in foul condition for any depth complete all as specified and directed.Note: Net contents of sludge shall be measured at the time of removal and paid. Quoted rate of tenderer is deemed to be inclusive of deqatering as required and nothing extra shall be admissible to te contractor on this account.(Sludge/ sludge water shall be diposed off in closed container authorized dumping site delared by local administration outside MD land as directed by Engineer-in-charge. 95 Excavation in soft/loose soilin trenches not exceeding 1.5 metrewide / manholes area n exc 10sqm on plan and depth not exceeding 1.5 metreand getting outcomplete all as specified and directed. 96 Returning, filling in soft/loose soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. 97 Removing excavated material to a distance exc. 50 metrebut not exceeding 100 metreand depositing where directed at a level not exceeding 1.5 Metreabove starting point, complete all as specified and directed. 98 Demolition and breaking up drain pipes of150mm dia (Salt glazed ware, AC or Reinforced concrete) set incement mortar complete all as specified and directed. 99 S&F 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed as specified and directed by Engr-in-Charge. 100 M&L, PCC 1:4:8 type D-2 using 40mm graded stone aggregate concrete bedding to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and directed 101 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra ement, including forms, moulds, mi- tred/stopped ends etc. 102 M&L factory made precast reinforced cement concrete 1:2:4, or higheras in cover slab of manholes, Drain etc, set in cement mortar 1:4 complete all as specified and directed. 103 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm bore pipes, complete all as specified and directed. 104 M&L for PCC 1:2:4 12.50 mm graded crushed stone aggrgate as in filling of pressed steel hollow frame door chowkhat complete all as specified and directed. 105 S&F sinks without drainage board of stainless made steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed 106 Dismantling of plane or corrugated galvalum, steel sheeting, any gauge, thickness including Nainital or similar pattern roof covring. 107 S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc. as specified & Directed 108 M&Lfor Complete removalofexisting/oldtreatmentbymannualy and mechnically andpreparation ofsurfacesusingnecessaryfillingcompound of puttyto obtainsmoothregular/evenfinishusingsandpaperandapplyingtwocoatsofexterior emulsion paint(tint as approved by GE ) over and including a coat of primer, on wall height upto7.50 mt.completeall as specified and directedbyEngineer - in- charge. 109 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc all as specified.Note : Credit for above items should be made as per conditions separately. 110 Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified. 111 M & L forPoint wiring complete with 1.5 Sq mm copper conductor single core FRLSH PVC insulated unsheathed 1100 V grade multistranded cable drawn in and including non metallic PVC rigid concealed conduit( not less than 20 mm dia) concealed in wall, ceiling with all accessories such as bends, reducer, spacers, junction boxes, pressed steel terminal boxes MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface , covered with 3 mm thick laminated sheet for mounting switch,sockets, fan regulator etc, including one running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly, complete all as specified and as directed. 112 (a) One light point controlled by one, one way switch 6 A, SP 113 (b)One ceiling fan/exhaust fan point controlled by one, one way switch 114 (c)One 3 point 6 Amps switch socket outlet point controlled by one switch on the same board. 115 (d)One 3 pin 6 Amps switch socket outlet point controlled by one switch on independent board. 116 Description all as per item No 111 here-in-before but using 4.0 Sq mm single core copper conductor cable of multistranded FRLSH PVC insulated unsheathed 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.0 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 117 S & F Switch pianotype single pole one way flush type 6 Amps capacity 230 volts. 118 S&F of Socket, two-in-one, 5 pin, 6 Amp, 230 volts, complete all as specified and directed. 119 S & Fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 6 Amps flush type complete all as specified. 120 S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universalcomplete all as specified 121 S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified. 122 S&F of Lamp holder, metal cased, bakelite body, 230 volts, complete all as specified and directed. 123 S&F LED lamp 9W complete all as specified and directed by the Engineer-in-Charge. 124 Supply and fixing LED lights fitting 20W, 6500K, efficacy greater than 100 lpw, decorative ultra slim square profile LeD lighting fixture with extruded polycarbonate, environmentalfriendly, energy efficient ready to use pack including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Cat Ref No LHEXACP7in1W020 of Havells or equivalent in list of makes. 125 Supply and fixing LED lights fitting 10W, 6500K, efficacy greater than 100 lpw, decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.Cat Ref NoLHEXACP7IN1W010 of Havells or equivalent in list of makes. 126 S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size 127 Supply and fix stepped type electronic ceiling fan regulator AC230 Voltssuitable for 1200 / 1400 mm sweep complete all as specified. 128 Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) without remote operated,complete all as specified and directed 129 S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed. 130 Supply and laying in repairs sub main wiring complete with 05 runs (3 nos for three phase, Neutral & Earthing ) of single core 10 sqmm FRLSHPVC insulated copper conductor cable multistranded and sheathedLT 1100 V grade drawn through and including concealed rigid PVC conduit of 32mm dia ISI marked andaccessories surface fixedon wall /flooretc, complete all as specified and as directed.Note:- 05 runs of cable 01 metre ,01 run of PVC conduit shall be measured and as one unit length. 131 Supply and laying in repairs submain wiring with two single core 10 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid FRLSH PVC conduit of 32 dia, conduit fittings and accessories concealed in wall/floor with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note 1:Three runs of 10 Sqmm cable, and one run of conduit shall be measured and as one unit length. 132 Supply and laying in repairs submain wiring with two single core 4.0 Sq mm PVC insulated unsheathed copper conductor multistranded 1100 Volts grade drawn in and including concealed rigid PVC conduit of suitable dia, conduit fittings and accessories concealed in wall/floor with one run of 4.0 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note 1: Two runs of 4.0 Sqmm cable, one run of 4.0 Sqmm earth contuinity conductor and one run of conduit shall bemeasured and paid as one unit length. 133 Supply and fixing Vertical TPN DB double door, IP 45 protection with powder coated enclosure 08 way insulated busbar assembly suitable for fixing MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed. 134 Supply and fixing sheet Metal enclosure double door type for DB’s 240 Volts Single Pole and Neutral 12 way with 200 Amps rated bus bar complete all as specified andas directed 135 Supply and fixing 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. 136 Supply and fixing MCB, TP, 63Amp, 415V 10KA C curve, complete with connection testing and commissioning. 137 Supply and fixing MCB SPN 40-63Amps , 240 volt, 10 KA,complete all as specified andas directed 138 Supply and fixing MCB single pole 6 to 32 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge. 139 Supply and fix factory made sheet metal enclosure, with socket plug top and MCB Triple pole with a three pin and earth plug and socket complete with and including one Triple pole MCB of capacity 32Amps, 415 Volts, B curve with breaking capacity 10kA etc., complete all as specified and as directed. 140 Supply and fixing Energy saving and environmental friendly long life 35W LED bldg security light having IP66 protection complete with all accessories incl three run of 1.5 Sqmm Copper conductor cable from security light to ceiling rose complete 141 Supply and fixing in repairs GI pipe bracket made of 40 mm bore light grade pipe made to shape of overall length of 1.2 mtr for fixing of security light fittingincluding MS clamps , nuts & bolts of required size complete 142 M&L for Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead 4mm dia, by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earth elelctrode to DBs/main switchincl provn of concrete pit in PCC , GI pipelight grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoalwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed. 143 Supply and fixing Air cooled split unit air conditioner (Indoor & Outdoor) electric driven single phase of capacity of 2 TR, BEE 5 star rated, Inverter AC, Copper, Convertible 5 in 1 Cooling, Multi Sensors, Dust Filter Blue Fins, Self Diagnosis, all as specified and directed by Engr-in-charge. 144 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. 145 Supply, install,commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (ovenbaked) with MS CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level fordoor openingsize 40x78 all as specified. 146 Supply and laying in replacement under-ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 70 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098 ( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and as directed. 147 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed 148 Removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the straight point 149 Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil. 150 Material andlabour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. 151 Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
Contract Date: Oct 10, 2025 Contract Value : 31.91 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Ref. Documents Contract Value : 46,000
Statutory Bodies & Commissions/Committees No of Bidders 1
37.
Educational and Research Institute #7859364 AOC
Supply Of Cctv, Photocopier Machine, Dlp Projector Office And Laboratory Equipments , Finance And Accounts Section , Photocopier Machine: Dadf, 25 Ppm, Print, Scan, Copy, Send Wi-Fi Network, Machine Type A3, Monochrome Laser Multification, Multiple Copies: Up To 9999, 2Gb Ram, 2 Cassette, 01 Byepass Tray, Duplex Print, Colour Touch Screen, Scan To E-Mail, Scan To Folder, Scan To Usb, Duplex Print, Duplex Scan Qr Latest Model With Stabilizer & Trolley.Ufr Ii Drivers, Ondemand Fixing Technology, Remote Operating Software Kit, Usb Host. , General Administrative Deptt , Photo Copier Machine:Warm-Up Time 18 Seconds 17.7 Seconds 18.6 Seconds 17.9 Seconds 19.1 Seconds 18.8 Seconds, First Output Speed: B/W 4.1 Seconds 3.9 Seconds 3.8 Seconds 3.6 Seconds 2.7 Seconds 2.3 Seconds, Continuous Output Speed 25 Ppm 30 Ppm 35 Ppm 40 Ppm 50 Ppm 60 Ppm, Memory: Standard 2 Gb Hdd: Maximum 320 Gb, Ardf Capacity 100 Sheets, Spdf Capacity 220 Sheets Weight With Ardf: 71 Kg With Spdf: 76.5 Kg,Dimensions (W X D X H) With Ardf: 587 X 673 X 913 Mm With Spdf: 587 X 673 X 963 Mm,Power Source 220 - 240 V, 50 - 60 Hz Copier Multiple Coping Up To 999 Copies, Resolution 600 Dpi,Zoom From 25% To 400% In 1% Steps , Cctv Camera And System , 32 Ch Nvr Supports Smart H.265+, H.265, Smart H.264+, H.264 And Mjpeg Decoding Formats. ? Max. Decoding Capability: 8 × 1080P@30 Fps Or 2 × 8 Mp@30 Fps. ? Max. 160/160/80 Mbps Incoming/Recording/Outgoing Bandwidth. ? Supports Ip Cameras With A Resolution Up To 12 Mp. ? Ai By Recorder Supports 4-Channel Smd Plus. ? Ai By Camera Supports Face Detection And Recognition, Perimeter Protection, Smd Plus, People Counting, Stereo Analysis And Heat Map. ? Supports Eptz, And One-Click Arming And Disarming Dh-Nvr 4232-4Ks2/L] , Hard Disk ; Supply & Installation Of Hdd-4Tb Capacity With Connection, Testing And Commissioning In Security Cabin. (As Directed By Engineer In Charge/ Elect. Consultant) Skyhawk 4 Tb Surveillance, Internal Hard Drive Hdd – 3.5 Inch Sata 6 Gb/S 64 Mb Cache For Dvr Nvr Security Camera System With Drive Health Management , Switch : 8+2 Port Poe Switch Gigaoutput,Supplying, Fixing, And Configuring, Web Smart Power Over Ethernet, Switch Of 8+2 Ports On Provided Rack, Suppling, Erecting & Testing Commissioning. , Camera: Dome Ip Camera 4-Mp 1/3 Cmos Image Sensor, Low Luminance, And High Definition Image. • Outputs Max. 4 Mp (2560 × 1440)@25/30 Fps. • H.265 Codec, High Compression Rate, Ultra-Low Bit Rate. • Built-In Warm Light, And The Max. Illumination Distance Is 15 M. • Roi, Smart H.264+/H.265+, Flexible Coding, Applicable To Various Bandwidth And Storage Environments. • Rotation Mode, Wdr, 3D Nr, Hlc, Blc, Digital Watermarking, Applicable To Various Monitoring Scenes. • Abnormality Detection: Motion Detection, Video Tampering, Audio Exception, Network Disconnection, Ip Conflict, Illegal Access, And Voltage Detection. • Built-In Mic. • 12 Vdc/Poe Power Supply [Dh-Ipc-T1b49p] , Surface Box: Surface Box Square 4X4 Inches (White) For Cctv Cameras , Monitor : 32 Led Monitor 80 Cm (32 Inches) G Series Hd Ready Smart Led Google Tv Ar32gt2841hdfl (Black) , Wireless Mouse : Wireless Mouse130 Wireless Compact Mouse, 1K Dpi Optical Sensor, 2.4Ghz Wireless Nano Usb, 10M Range, 3Button(Left,Right,Scroll) Up To 3M Left/Right Clicks, 10Month Battery, Ambidextrous, Ergonomic, Gy51l52638 , Cable:Cat-6 Cable Per Ft With Pipe Fitting .Heavy 0.51Mm Copper Gauge.Ec Grade Copper. International Standard Twisting .Outer Hdpe Jacket. Fluke Tested (In Rft) , Connectors:Connectors With Networking D-Link(India) Rj45 Connector Module Plugs. All Networking Clip, Rj45 Connector Colour White , Camera Installation Charges , Tv Stand: Tv Stand 18-55.. Sk Expertise Wooden Wall Mounted Tv Unit, Tv Cabinet/ … , Switch:8 Port Desktop Switch Gigabyte Up To 2000 Mbps. Ieee 802.3X Flow Control.Plug And Play Installation. , Central Administrative Service Unit (Rs. 220000.00) , Cctv Camera , 8 Ch Hd Dvr , 1000Gbhard Disk (Sv 35) Sata Hd , Dome Hd Camera , Installation Charges , Photocopier Machine:Faction: Print /Scan /Fax/E-Mail, No. Of Trays-2, Color-Black And White, Print Technology= Laser, Print Speed:30 Ppm, Supporting Paper Size:A3, Memory: 2 Gb, Warn Up Time: 4 Second Or Less, Resolution 1200X1200,Processor: 1.6Ghz Dual Corel Processor, , Innovation, Incubation & Linkages , Photocopier Machine: Speed B/W:25 Pages Per Minute, Resolution: 1200 X 1200 Dpi, Toner Impression B/W: 14,600 Impressions, Copier Type: Office Copier, Colour Capability: Black And White Copier, Properties : Copier-Printer-Scan-Fax Etc., Dimensions (Hxwxd):35-3/4” X 22-1/4” X 27-1/8”, Weight: 174 Lbs,Power: 120 Volts, 9.3 Amps , Collegiate Section , Multifunction Photocopier Machine: Dadf, 25 Ppm, Print, Scan, Copy, Send Wifi Network, Machine Type A3, Monochrome Laser Mulification, Multiple Copies: Up To 9999, 2Gb Ram, 2 Cassette, 01 Bypass Tray, Duplex Print, Colour Touch Screen, Scan To E-Mail, Scan To Folder, Scan To Usb, Duplex Print, Duplex Scan Qr Latest Model With Stabilizer & Trolley.Ufr Ii Drivers, Ondemand Fixing Technology, Remote Operating Software Kit, Usb Host. , Boy’S Hostel , Ip Camera Dome 2 Mp: Image Sensor-1/2.8 Progressive Scan Cmos, Min. Illumination-Color: 0.002 Lux @ (F1.4, Agc On), B/W: 0 Lux With Ir, Shutter Speed-1/3 S To 1/100,000 S, Wide Dynamic Range -120 Db, Day & Night-Ir Cut Filter, Angle Adjustment-Pan: 0° To 360°, Tilt: 0° To 90°, Rotate : 0 To 360, Lens Type-Fixed Focal Lens, 2.8, 4, And 6 Mm Optional, Itis Types-Fixed, Aperture-F1.4, Supplement Light Type-Ir, Ir Range-Up To 40 Mtrs, Ir Wavelength-850 Nm, Smart Supplement Light-Yes, Max Resolution-1920 X 1080, Video Bit Rate -32 Kbps To 8 Mbps, Environment Noise Filtering - Yes, Audio Sampling Rate-8 Khz/16Khz/32Khz/44.1 Khz/48Khz, Built-In Mic-Yes, Audio Compression-G.711Alaw/G.722.1/G.722.1/G.726/Mp2l2/Pcm/Mp3/Aac-Lc, Ethernet Interface - 1 Rj45 10 M/100 M Self-Adaptive Ethernet Port, On Board Storage - Built In Memory Card Slot, Support Micro Sd/Sdhc/Sdxc Card, Up To 512 Gb, Basic Event-Motion Detection (Human And Vehicle Targets Classification), Video Tampering Alarm, Exception, Face Capture - Yes, Perimeter Protection-Line Crossing Detection, Intrusion Detection, Region Entrance Detection, Region Exiting Detection, Protection Ip67 (Iec 60529-2023), Ik10 (Iec 62262:2002). , Ip Camera Bullet 2 Mp Image Sensor-1/2.8 Progressive Scan Cmos, Min. Illumination-Color: 0.002 Lux @ (F1.4, Agc On), B/W: 0 Lux With Ir, Shutter Speed-1/3 S To 1/100,000 S, Wide Dynamic Range -120 Db, Day & Night-Ir Cut Filter, Angle Adjustment-Pan: 0° To 360°, Tilt: 0° To 90°, Rotate: 0° To 360° ,Lens Type-Fixed Focal Lens, 2.8, 4, And 6 Mm Optional, Iris Type -Fixed,Aperture-F1.4,Supplement Light Type-Ir,Ir Range-Upto 40 Mtrs, Ir Wavelength-850 Nm, Smart Supplement Light-Yes, Max Resolution-1920 X 1080,Video Bit Rate- 32 Kbps To 8 Mbps, Environment Noise Filtering- Yes, Audio Sampling Rate- 8 Khz/16 Khz/32 Khz/44.1 Khz/48 Khz, Audio Compression- G.711Ulaw/G.711Alaw/G.722.1/G.726/Mp2l2/Pcm/Mp3/Aac-Lc, Ethernet Interface -1 Rj45 10 M/100 M Self-Adaptive Ethernet Port, On-Board Storage -Built-In Memory Card Slot, Support Microsd/Sdhc/Sdxc Card, Up To 512 Gb, Basic Event-Motion Detection (Human And Vehicle Targets Classification), Video Tampering Alarm, Exception, Face Capture- Yes, Perimeter Protection-Line Crossing Detection, Intrusion Detection, Region Entrance Detection, Region Exiting Detection, Protection -Ip67 (Iec 60529-2013) , 32 Channel Network Video Recorder 2 Mp: Up To 32-Ch Ip Camera Inputs H.265+/H.265/H.264+/H.264 Video Formats Up To 12 Mp Resolution, Hdmi 1 -4K (3840 × 2160)/60Hz, 4K (3840 × 2160)/30Hz, 2K (2560 × 1440)/60Hz, 1920 ×1080/60Hz, 1600 × 1200/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 ×768/60Hz, Hdmi1/Vga Simultaneous Output, Hdmi 2-1920 × 1080/60Hz, 1280 × 1024/60Hz, 1280 × 720/60Hz, 1024 × 768/60Hz,Hdmi2/Vga Independent Output, Network Protocol-Tcp/Ip, Dhcp, Ipv4,Hikconnect , Dns, Ddns, Ntp, Rtsp, Sadp, Smtp, Snmp, Nfs, Iscsi, Isup, Upnp™, Http, Https,4 Hdds For Continuous Video Recording, Up To 10Tb Capacity For Each Disk,4 Sata Interfaces Supporting Hot-Plug, Up To 256 Mbps Incoming Bandwidth, Network Interface -2, Rj-45 10/100/1000 Mbps Self-Adaptive Ethernet Interfaces, Audio Compression -G.711Ulaw/G.711Alaw/G.722/G.726/Acc/Mp2l2,Audio Output-1-Ch, Rca (2.0 Vp-P, 1 K?, Using The Audio Input ),Audio Input -1-Ch, Rca (2.0 Vp-P, 1 K?),Facial Detection And Analytics-Face Picture Comparison, Human Face Capture, Face Picture Search, Face Picture Library-Up To 16 Face Picture Libraries, With Up To 10,000 Face Pictures In Total (Each Picture= 512 Kb, Total Capacity = 150 Mb),Face Picture Comparison-4-Ch Face Picture Comparison Alarm, Performance Of Facial Detection And Analytics-1-Ch Human Face Capture (Hd Network Camera, Up To 4 Mp, H.264/H.265), False Alarm Protection (Perimeter Protection) - Up To 4-Ch 2 Mp (H.264/H.265) Video Analysis For Human And Vehicle Recognition To Reduce False Alarm; Up To 12 Rules In Total, , Surveillance Harddisk 6 Tb , Network Switch Poe 16 Port, 16X10/100/1000 Base-T Poe Port With 2 Sfp Uplink. 1610/100/1000 Mbps Gigabit Ethernet Ports 2 Sfp Port, 150 Watts Available Poe, Flow Control For Protection Against Data Loss, Maximum Distance Of 250M, Light Protection (6Kv), Operating Temperature : 0 To 400 C (32 To 104 Deg F) , Dome Camera Wall Mount Pvc Stand , Pvc Junction Box , 32 Let Tv (An Reputed Brand) , Cat6 Cable (Approx. 1525 Mtrs) (In Rmt) , Cable Laying Charges (Cat6 Cable) (Approx. 1525 Mtrs) (In Rmt) , Conduit Pipe / Casing Patti With Saddled Fitting ( Approx. 400 Mtrs.) , Single Mode Six Core Optic Fiber Cable (Armored) (Approx. 800 Mtrs.) , Optic Fiber Cable Paying Charges (Overhead) (Approx. 800 Mtrs.) , 1000 Base - Mini Gigabit Interface Converter , Fiber Patch Cord With Splicing Charges , Hdmk Cable 15 Mtrs. 4K , Network Rack 6U With Fan, Pdu & Standard Accessories. , Network Rack 15U With Fan, Pdu & Standard Accessories. , Setup, Installation, Crimping, Punching & Supervision Charges With One Year Warranty & Support. , Biometric Attendance System With Backup Power Supply: Face/Finger/Rfid Attendance Reader (500 Faces, 2000 Fingers, 1,00,000 Logs Tcp Ip Usb) Suitable Up To 100 Students) Type - 100 % Copper Model , Biometric Attendance System With Backup Power Supply: Face/Finger/Rfid Attendance Reader (3000 Faces, 4000 Fingers, 1,00,000 Logs Tcp Ip Usb) Suitable 100 To 3000 Students) High End. , Ro 120 Liter, 300 Gpd Pump 3 No., 300 Gpd Membrane 4 No., 20 Inch. Housing 3 No., 20 Inch Pre-Filter 1 No., 20 Inch. Carbon Filter 1 No., 20 Inch Sediment Filer 1 No., Fr- 600 3 Nos., 3/8 Pipe 25 Rft., Filter Set 10 Inch 4 Nos. , Deptt. Of Lifelong Learning &Extn. , Photocopier Machine:Multifunction Machine, Print Technology: Lazar, Mono Printing, And Cartridge Tech: Separate Drum And Toner (Dual Component), A3, Ram: 2048 Mb, Scanning Feature, Networking Feature, Ethernet 10/100/1000, Wi-Fi Direct. , Girl’S , Providing And Fixing Pa Ip Based Paging System With Automatic (Digital Timely Audio Playback System , Providing And Fixing Ip Based Network Paging Mic Console (Digital) , Providing And Fixing Ip Based Pa Network Intercom Unit , Providing And Fixing Software For Internet Protocol System (Ip Based)Software Features: User Management, Terminal , Providing And Fixing 415W Rack Mounting Installation Pa Amplifier , Providing And Fixing 25 W Ip 65 Sound Projector(With Lmt) , Providing And Fixing Pa Paging Microphone (With Chime) , Providing And Fixing15w Pa Column Speaker (With Lmt) , Providing And Fixing 6Wpa Wall Speaker (With Lmt) , Providing And Fixing Pa Active Monitor Speaker , Providing And Fixing 12U Lockable Metal Rack For System , Csr No. 13-9-10: Supplying, Erecting, Testing And Commissioning Of 1.5 Sq. Mm. Speaker Wire Complete (In Mtr) , Csr No. 1-2-9: Supplying, Erecting Pvc Tuning (Pvc Casing-N-Capping) Of Size 20 Mm With Accessories On Wall/Ceiling As Per Specification No. : Wg-Ma/Con (In Mtr) , Csr No. 1-14.46: Supplying & Installing Utp Networking Cat 7 Cable, 4 Pair 23, Awg Cate 6A Lszh Lan Cable, Standards Like Ansi/Tia 568, C.2, En50173, Iec 11801 2Nd Ed, 600 Mhz Speed Frequency Tested Up To 700Mhz With Third Party Certificate Etc. Complete. (Inmtr.) , Csr No. 1-14-1: Supplying, Installing & Testing Uto Connector (Rj-45) As Per Specification No. Wg-Nas/Utpc , Biometric Attendance System With Backup Power Supply : Face/Finger/Rfid Attendance Reader (500 Faces, 2000 Fingers, 1,00,000 Logs Tcp Ip Usb) Suitable Up To 100 Students) Type - 100 % Copper Model , Biometric Attendance System With Backup Power Supply: Face/Finger/Rfid Attendance Reader (3000 Faces, 4000 Fingers, 1, 00,000 Logs Tcp Ip Usb) Suitable 100 To 3000 Students) High End. , Projector Screen : Royalty Licking Projector W-121.92 Cm X H-182.88 Cm , Lcd Tv : 49 Full Hd Resolution, Wall Mountable, Smart Phone Connectivity, Usb Port Latest Model. , Deptt. Of Biotechnology , Pcr System (3X32- Well)Block Format Interchangeable Thermal Accuracy: +- 0.25°C (35°C-99.9°C), High Throughput Compatibility Thermal Uniformity: ?0.5°C (20 Sec After Reaching 95°C) Reaction Speed Fast, Standard Dimension: 22X13x10.6 In. ( 56.5X33x27cm) Capacity : 32X0.2Ml Pcr Tube/Block Or 4X8wells Strips Of 0.2Ml Pcr Tubes/Block Voltage : 100/240V Display Type : 8.4 In Color Tft Lcd Touchscreen Product Type : Thermal Cycler, Warranty :Limited Warranty Thermal Range 0°C-100°C For Used With (Application) Pcr Programs Auto Restart (After Power Outages), Program Overwrite Protection User Interface Usb Wifi Cloud, Ethernet Max.Ramp Rate 6°C /Sec. (Block), 4.4°C, Sec (Sample Memory Usb And On-Board Weight: 41Lb.(18.8Kg) Block Configurations : 3X30well 2 Zone Veriflex Block , Autoclave Portable: All The Parts Are Made Ss-304 Grade, Easily Replicable Heater And Rubber Gasket Pressure Gauge And Spring Loaded Safety Valves And Steam Release/ Exhaust Vavae Fitted On Lid, Operates On 230 Volts Ac Single Phase 50Hz, Size: 12”X12”. , Analytical Balance:Capacity: 220Gm, Readability: 0.01Gm, Reparability: 0.001Mg Response Time: 2-3 Sec, Pan Size:128X128mm, Display: Lcd Backlight Calibration: External Calibration. , Mini Vertical Page Electrophoresis System:Mini Vertical Systems Are Predominantly Used For Protein Electrophoresis. Electrophoresis System Can Accommodate Up To 4 Hand Cast Gels And To Commercial Precast Gel To Provide Complete Flexibility For Individual Research Needs While Unique Sliding Clamp Technology Within The Page Insert Facilitates Samples, 1Mm Thick Combes Including Caster. , Automated Densitometer With 4 Reading Channels: Densitometer A Universal Densitometer Scanner With Software Capable Of Reading 144Testper Min. Is Available For Band Quantitation Following Post Electrophoresis Staining Ordering Information-Cellas Gel Application Packages Equipped With Bridges Applicator And Clinical Test Kit, 1X4 – Specimen Semi Micro Applicator Volume Applied/Sample Band With Compatible Strip Size: 5.7X14cm, Cellasgel Wet Membrane Bridges And Densitometer, 1X8.5 Cm Bridge For 1X5.7X7x14cm Or 2X2.5X14cm Cellasgel.Strip Cat No. Cslbg8.55 Terbo Scan Software Densitometer (Excludes Computer And Scanner) Cat No. Csldens Flat Belt Scanner For Turbo Scan Software Cat No. Csscan , Uv Transilluminator: 312 Nm Singlewavelength Transilluminator For Detection Of More Than 0.1Mr Of Dna Filter Area (Cm) Uv 20X20cm. , ?Controller Baed Ph System:Touch Screen Display 4.3 Ubcg Tft, User Password Protection Available Microprocessor Controlled And Completely Programmable, Large Lcd Display With Time Setting, Temperature Indicator And Controller, Autotuning For Convenience And Optimal Processing Efficiency, Variable Power Output Control, , Auto Frequencytrucking Output Aptitude 0-100% Adjustment Automatic Fault Alarm Frequency 2-25Khz-Automatic Typing Process Capacity 0.5-500Ml (Approx..) Probedie (Titanium Alloy Std. 6Mm (1/5 Inch) , Deptt. Of Botany , Gel Viewing Model Endure: High Sebsututy Fir Dna/Rna Detection, Compatible With Sy Br Green Family Stains, Provision Of Window With Uv Protecting Shield For Safety From Uv Damage, Quartz Ultra Violet Light For Longer Shelf Life, Side Doors For Precise Cutting Of Gels, Use Of White Light, 302Nm, 254Nm, And 365Nm Uv Wavelength Having Emission Of Average Light Power On The Plate To Obtain Shadow Free Images, Transilluminator Is Housed In A Closed Chamber For Case Of Gel Observation And Graphic Display Capturing Under Daylight, White Light Board Available At Additional Price. , Rotary Evaporator:Automation Grade: Automatic, Capacity: Standard, Water / Oilheating Bath With Wide Temperature Range:Temp.: Ambient To 200 Deg. C (Accuracy ± 0. 5 Deg. C)Rpm : 10 To 150 (Accuracy ± 1 Rpm), Sensors : Pt – 100, Display : Lcd 16X2, Heater : 1000 Watts Stainless Steel, Power# : 220 / 230V Ac, 50 Hz 01 , Incubator And Oven Dual Model Twin: Horizontal Air Circularly By Double Air Duct,High Efficiency And High Uniformity Pid Controller Etc , Precision Balance: Display Green Led Display, Minimum Capacity 20 G, Maximum Capacity 1000G , Readability 20 G, Repeatability 0.02 G, Stabilization Time 1 Seconds, External Calibration Weight 500 G, Net Weight 5 Kg , Programmable Micro Centrifuge:Lcd Display, Rotor Capacity: 12 Places X 1.5/2 Ml Tubes, Centrifugation Speed: 500-15000 Rpm, Timer : 15 Seconds To 99 Minutes, Power Supply: 110V-240V; 50 Hz, Power Consumption 100 W, Dimensions: 230 X 220 X 130 Mm, Approximate Weight: 6 Kg. , Multimedia Projector:Display Type: Lcd, Brightness:2000-4000 Lumens, Resolution:Wxga Resolution,Lamp Life: Long Lamp Life Up To 12,000 Hours*2 In Eco Mode, Long Lamp Life:Up To 12,000 Hours*2 In Eco Mode, Connectivity: Hdmi Connectivity, Projection Technology: Rgb Liquid Crystal Shutter Projection System (3Lcd), Direct Power On / Off: Yes , Ph Meter : Range- 0.00-14.00, Calibration- Auto Calibration With Slope Display , Distillation Unit: Led Indicator, Energy Efficient And Eco-Friendly, Water Tank Capacity 4L, Water Distillation Capacity 1.5 L/Hr , Stereo Trinaculor Microscope: Smoot Focus Control And A Fluid 0.8X-8X Greenough Zoom System Guarantee Stress Free Operation With Minimal Ware And Tare To Gears. Excellent Image Quality And Optional Performance With Infinity Parallel Optical System.Comfortable Operation With Ergonomic Design Principal With Led Light For Both Incident And Transmitted Illumination.Providing Even Illumination And Life Expectancy Can Reach 6000 Hrs.A Wide Rang Of Accessories To Be Equipped With The Microscope For Multi-Purpose.It Is An Outstanding Assistant In Industrial, Medical And Scientific Research Areas. Optical Syst4em: Greenough, Zoom Ration: 1:10, Eyepieces: Wide Field 10X/22Mm/23Mm (Optional, Objective: Plan Objective 1X,Viewing Body: Binocular / Trinacular With Beam Splitter, Working Distance: 78Mm, Magnification Range: 8X To 80X (Click Stop) With 10X Eyepieces, Object Field Diameter: 6.6Mm To 28.5 Mm, Eye Guards: Rubber, Retractable, Illumination Control: Incident/ Transmitted / Combined Illuminations Control Buttons With Rheostat Dial For Light Intensity Control, Led: Led 3.3W With Intensity Control With 60,000 Working Hours, Free Of Uv And Ir Emissions, Power Supply: Universal 220-240V/60Hz Integrated Power Supply With Voltage Flux Stabilizer, Optional Accessories: Pointers, Micrometre Reticules, Eyepieces (15X20x, 25X), Auxiliary Lens 0.3X, 0.5X0.5X, 2X). Digital Cameras Usb 3.0, Hdmi Camera, 4K Camera, Retina Display System, Dark Field Withy Tweezer, Battery Back, Fluorescent Attachment Kit. , Side-By-Side Refrigerator : 564 L Frost Free Multi Air Flow System Side-By-Side Refrigerator (Rs Eonvelvet 579 Rfd Pl St, Platinum Steel, With Advanced Controls) , Binocular Microscope:4X, 10X, 40X And 100X Monocular Head, Trinocular Head, Usb Digital Camera , Double Beam Portable Uv Visible Scanning Spectrophotometer, 190-1100 Nm:Wavelength Range:190-1100 Nm, Optical System: Double Beam, Mobility: Portable, Spectral Bandwidth: 1 Nm,Wavelength Accuracy+-0.3 Nm, Wavelength Repeatability+- 0.2 Nm, Photometric Accuracy+- 0.3% T, Lamp Type Deuterium Lamp, Usage / Application, Lab And Industrial Use, Material Plastic, Steel, Standard Iso Certified, Display Digital , Plant Growth Chamber :Temperature Range Lights Off: 5°C To 60°Clight On: 10°C To 60°C. Incorporated With Microprocessor Based Programmable Pid Temperature / Humidity Control System For Accurate Control Of Humidity. Temperature And % Of Rh Are Displayed On Digital Meter, Programmable Timer For Regulating Day / Night Effect, Temperature Range: 10°C To 50°C, ± 0.5°C, Humidity Range : 40% To 95% + 2% Rh, Light Level : 2,000 To 16,000 Lux, Capacity : 200 / 400 / 800 / 1000 Litres , Business Administrative And Management , Podium Lectern:Public Address Podium With Wireless Mike, Lecture System, (Receiver Amplifier Power Output 60 Watts, Max. Speaker Impedance (External) 4 W Input Channels Sensitivity Mic 1:12, 0Mv Mic. 2-7 Mv, Aux Positional 1:350Mv, Aux Position 2:180Mv, Aux Position 3, 300Mv, Aux Position 4-700Mv, Frequency. Response Tom=Ne Control Bass +/- 10Db At 80 Hz, Treble +/-6Db At 8, Khz, Rec Output-Iv, Power Supply Ac 220-240V, 50/60 Hz, Power Consumption Ac 100W, Dimensions W 420Xh1100xd5800mm, Weight 108.30Kg, Handheld Wireless Transmitter Microscope Dynamic Unidirectional Stability Various Emissions 45Db, Rf Output Power, 15Mw, Frequency Response 80-16.000Hz, Dynamic Range 100Db Or (Latest Version) , Wireless Microphone Awm-800U2 Dual Pa Microphones (Set) , Collar Mic With 50-Meter Range , Trolley Speakers:Partyboxx310 Portable Bluetooth, Party Speaker 240W, Monstrous Pro Sound Dynamic Light Show Backlit Panel, Telescopic Handle And Wheels, Guitar & Mic Support Party Box App (Black , Deptt. Of Chemical Technology , Temperature Control Trainer: The Process Setup Consists Of Heating Tank Fitted With Thermistor-Controlled Heater For On Line Heating Of The Water. Water Is Supplied From Laboratory Constant Head Tank And Its Flow Can Be Manipulated And Measured By Provided Rotameter. The Temperature Of The Heated Water Is Sensed By Rtd Sensor. This Measured Variable Through Temperature Transmitter Is Communicated To Digital Indicating Controller. Error Is Calculated And Output, Accordingly, Is Communicated To Thermistor Controlled Heater To Achieve The Set Point. These Units Along With Necessary Piping Are Supported In A Well-Designed Housing And Are Fixed On Base Plate.Water Supply 2 Lpm. Electricity Supply: 1 Phase, 220 Vac. Temperature Transmitter : Input Rtd Pt-100 (0-100°C), Output 4-20 Ma. Process Tank : Material Stainless Steel, Capacity 0.5 Lit, , Emisivity Measuremet Apparatus:Specifications: Test Plate And Black Plates - 160 Mm. Dia, Aluminium Plates, Mounted In Panel With Mica Heater Inside. Instrumental Panel Consisting Of Digital Voltmeter And Ammeter For Input Measurement To Both Heaters Through A Selector Switch. Separate Dimmer Stat For Both The Plates.Multichannel Digital Temperature Indicator.A Technical Manual Accompanies The Unit.The Unit Provided With An Attractive & Rust Proof Powder Coating. Services Required 1) Space Area Of 1.5M X 1M. At Working Height. 2) 230V, 15A, Ac Supply With Earthling Connection. , Spiral Type Heat Exchanger: The Unit Consists Of A Spiral Type Heat Exchanger, In Which Cold Fluid Is Cold Water And Hot Fluid Is Hot Water, Which Is Obtained From A Water Heater. The Inlet And Outlet Connections Of The Fluids Are Positioned So As To Make The Exchanger Counter Flow Type. Hot And Cold Fluids Pass Between Alternate Plates. Various Measurements Provided Enable The Students To Determine Heat Transfer Rate, Lmtd, Heat Transfer Coefficients And Effectiveness Of The Heat Exchanger. Specifications 1) Heat Exchanger – Spiral Type Heat Exchanger 2) Hot Water Heater -3 Kw Capacity. 3) Measurement Flask 4) Thermocouples To Measure Inlet And Outlet Temperatures Of Water. 5) Flow Control Valves. 6) Digital Temperature Indicator. 7) Hot & Cold Water Pumps To Circulate Water. A Technical Manual Accompanies The Unit. , Thermal Conductivity Of Metal Rod : Technical Specification: Metal Bar: Material-Copper; Length 400 Mm (Approx.); Diameter: 25 Mm, Insulating Shell: Length 250 Mm; Diameter 200 Mm, Cooling Water Jacket: Length 75 Mm; Diameter 100 Mm, Heater: Nichrome Wire., Water Flow Measurement: By Measuring Flask, Control Panel Comprising Of Digital Voltmeter: 0-250 Volt., Dimmer Stat : 0-230 V; 0 - 2 Amp, Temperature Sensors: Rtd Pt-100 Type., Digital Temp. Indicator: 0-199.90C, With Multi-Channel Switch, With Standard Make On/Off Switch, Mains Indicator Etc., The Whole Setup Is Mounted On A Powder Coated Base Plate., Control Panel: Standard Make On/Off Switch, Mains Indicator Etc., Instruction Manual : An English Instruction Manual Will Be Provided, Along With The Apparatus , Stefan Boltzmann Apparatus : Hemisphere : Dia 200 Mm Approx. Made Of Copper, Jacket: Die 200Mm Approx. Made Of Steel, Watertank Stainless Steel 12 Litre Capacity, Heater: Nichrome Wire Immersion, Digital Temp Indicator: 0 To 250 Degree Celsius, Temperature Sensor:, Thermocouples Cr-Al Type-5 Nos , First Order System : Thermometer Range -10°C– 0 – 100°C Thermometer, Tube Id 22Mm Heating Bath, 315Mml, Ss304. Heater Type Electrical Coil, Capacity 3 Kw. Timer Type Cyclic Beeper Time Setting Range 2-10Sec. , Forced Convection Apparatus : Control Panel -Stand Alone Metallic Powder Coated Panel, Specimen: 32Mm, Dia, 3 Mm Thick, 400Mm Long – Copper, Blower: 650W, Volume Of 3M3/Min, Reputed Make , Heater: 32 Mm Dia, 75Mm Width Band Heater -250Watts , Manometer: 6” U Tube Manometer With Water, Voltmeter: Digital Voltmeter Of ,Range 0-300V Ac , Ammeter: Digital Ammeter Of Range 0-20A Ac, Temperature Indicator: Digital Temperature Indicator ,0-400°C .Thermocouples: Teflon Coated Cr –Al (K-Type)-8 No., Dimmer Stat 230V,2A. , Friction Factor (Pipe Lines) Apparatus : Block Type Acrylic Differential Manometer (250-0-250 Mm), Flow Control Valve To Change Discharge, Two Pipes – (Length Of Pipe Between Two Pressure Tapings 1 Mtr) A) Dia Of Pipe - 0.022 M (For Pipe 3/4”), B)Dia Of Pipe 0.016 M (For Pipe ½ “Transparent Pizometer Tube With Scale To Measure Measuring Tank Discharge Measuring Tank 295 X 345 X 345 Mm Usha Or Crompton Greaves Motor For Recalculating Type Unit - 0.5, H.P. Self Priming ,Stop Clock, All The Tanks Are Provided With An Attractive Antirust Powder Coating. , Centrifugal Pump0.5 Hp , Centrifugal Pump 1Hp , Vacuum Pump: Specification Model: Dc ? Voltage / Freq.: 100~240V, 50/60 Hz, Max. Power: 120W, Max. Vacuum: 7 Mba, Max. Flow Rate: 37 L/Min,Resolution: 1 Digit,Pressure Display: Mbar, Hpa, Torr, Display:7” Touch Screen, Measuring Range: 1100 ~ 0 Mbar Abs., Measurement Accuracy: ± 2 Mbar (After Adjustment, Constant Temp.), Setting Range: 1013 ~ 0 Mbar, Motor Speed: 1-100 %, Adjustable, Housing Material: Ss304, Plastic, Venting Valve: Yes, Auto-Cleaning: Yes,Noise Level: 50 Dba, Hose Barb: Id 10,Moisture Trap: Yes,Safety: Fuse, Error Message,Dimension ( L X W X H ): 44 X 38 X 25 Cm, Net Weight: 15 Kg , Lcd Projector - Ultra X 35U, Display Type – Dlp, Brightness - 3000 Lumens, Resolution - 1024X768 Pixel, Throw Ratio - 1.5 ~ 1.65 M, Projection Size - 0.76-7.62 Mtr, Contrast Ratio - 22000:1, Computer Compatibility - Vga (640 X 480) To Wuxga (1920 X1200), Power Supply (Voltage, Hz) - Ac100 To 240 V, 50 To 60 Hz, Aspect Ratio - 16:9, Weight - 2.8 Kg, Projection Lamp- 210 W Zoom - 1.3: 1, Dimensions - 311.81 X 104.7 X 244.12 Mm With Ceiling Installation Bracket, Cable, Socket And All Accessories Pins. With All Installation Charges. And Screen Fitting On Wall , Variable Speed Peristaltic Pump : Flow Range: 0.0015-1140Ml/Min, Adjustable, Speed Range: 0.1-300Rpm, Resolution: 0.1 Rpm, Flow Rate Variable From : 0.0015-1140Ml/Min, Flow Error <0.5%, Display: 4 Led Display Current Speed Or Flow Rate, Speed Control: Digital Knob Control, Power< 35W, External Control Interface: Start/Stop, Direction, Speed Control (Optional), Rs485serial Communication, Operating Conditions: 0-400C Temperature, Relative Humidity<80%, Drive Dimensions: 234×144×140Mm, Drive Weight: 4.3Kg Ip: Ip 31 , Portable Digital Thermometer : Precision Portable Digital Thermometer With 7-9 Inch Long Probe Temperaturerange: 750Oc Or More , Portable Digital Thermometer : Portable Digital Thermometer With 20 Inch Long Probe, 4 Mm Diameter, Temperaturerange: 750Oc Or More , Cloud & Pour Point Apparatus: Double Wall M. S. (As Per Ip 58 Astm – D-36, Astm – E – 28 & Is 205/78), For Two Tests: The Apparatus Consists Of Stand Units With Drain Plug And Cover With Provision For Fitting Thermometer And A Filling Aperture For Adding Freezing Mixture. Glass Jars For Containing Oils, Jackets, Discs And Gaskets As Specified , Labblender: Blender Type:-Seven Speed Blender, Rpm:-3500 To 22000, Container:-Stainless Steel Jar-Glass Jar (Auto Cleavable) Controls:-Push Buttons Capacity:-1 Liter Power Supply:-220 Volts Safety Feature:-Circuit Breaker Certification:-Ce Marked , High Pressure Reactor For Hydrothermal Synthesis With Heater & Control System : Setup Consists Of The Following Teflon Lined High Pressure Vessel With Heating & Control System With Agitation Facility (Magnetic Stirrer A) Ss Pressure Vessel:- M.O.C. Ss-316 Wall Thickness:9-10Mm (Approx..0 Made From Ss-316 Solid Bar Stock , Vessel Head:-M.O.C. Ss-316 It Will Consists Of A)Pressure Gauge : 2” Dia (Ss-316) End Connections: ¼” Bsp Male Range; 0-20 Kg/Cm2 Threaded Connections Will Be Provided For Pressure Gauge & Temp.Sensor B) Heating System: Heating Source : Ceramic/Mica Band Heater Of Suitable Dimensions Will Be Provided Power Supply : 230V Pt:-100 Sensor: Provided Temp. Control ; By Pid Temp. Controller Cum Indicator Display: Digital C) Teflon Vessel: M.O.C. : Teflon (Ptfe) Wall Thickness ; 3-4 Mm (Approx.) Volume; 50-200 Ml (Approx...0 Safe Operating Temp: 160Oc (Approx...) D) Stirring / Agitation ; Suitable Magnetic Stirrer For Stirring Application With Digital Display Of Rpm/Speed Teflon Coated Bar For Stirring : Provided Application : For Hydrothermal Synthesis/Material Synthesis Supplied With Viton “O” Rings Part No. Hbs-Vr-01-02 Nos Ellen Key- 02 Nos Ellen Bolts – 06 Nos , Deptt. Chemistry , Sound System For Auditorium Hall : Sound System Aba5000 =02 Nos. Active Speakers-Aba4000- 02Nos, Mixer-Premix – 1442=01 Nos, Uhf Wireless Mic (Dual) Awm 700 Ul- 01 No., Wireless Microphone Awm-800U2 Dual Pa Microphones (Set) Including All Setup In Hall (In Set) With Installation , Aspirator Waterjet Vacuum Pump: Jet Vci Ji, Suitable Water Circulator Pump, 0.5 Hp Ss Water Tank , Ss Cabinet Cover Jet With Two Non Return Valve, 70 Mm Hg , Magnetic Stirrer: With Hot Plate, Regulator , Digital Electronics Balance: Capacity 0.0001 To 200 Gm , Fume Hood For Laboratory:Rectangular Std. Size, Fibre Fabricated, 4 Ftht, 850 Mm Work Space , Eye Wash Station:Designed To Deliver Fluid To Both Eyes Simultaneously Flow Rate Of Not Less Than 1.5 Litres/Minute , Microwave Synthesis System: Cap 3 Lit, Power 700 Wt, Automatic Soft Touch Control Panel , Hot Plate: Circular, With Temp Control, , Capillary Column For Gas Chromatograph For Natal Ultimo 2100 Model:2 Mm Mesh Size 80-100 , Deptt. Of Home Science , Mixer Grinder : 1000 Watt Heavy Duty Motor, Capacity 1 Liters No. Of Speeds -3 Stainless Steel Jars With Efficient Blades, (1 Ss Wet Jar With Blade, 1 Ss Dry Jar With Blade, 1 Ss Chutney Jar With Blade And Juicer). , Air Fryerdigital: 6.5 Lit / 1500 Watt ,Advance Digital Display Fry ,Bake Roast Wi-Fi Enabled , Induction Base Cookware: Sandwich Bottom, Stainless Steel Cookware With Lid And Fry Pan Compatible With Induction Cooktop And Gas Stove Capacity 1. 5 L, / 2.5 L And 3 L ( 3 Cookware’Sof Different Capacities And Fry Pan ) (In Set) , Weighingbalancedigital :6000 Gm X100mg , Superiorperformancepowercharge , Cd 300 Remote Display , Wireless Microphone System: Dimension-16.2X11x5.2Cm:300 Grams, Batteries -1 Lithium Polymer Batteries Required (Included) Hardware Platform-Smartphone. Tablet Compatible Devices -Camcorder, Tablet, Headphone, Smartphone. Special Features –Wireless , Mounting Hardware – Transmitter, Receiver,2 Wind Muff, One With Twocable, Dslr Cable, 2 Monitor Earphone.One Lighting Cable. ,Noise Level -75 Db ,Microphone Format –Microphone System ,Power Source –Battery Powered ,Battery Cell Composition –Lithium Polymer, Signal –To – Noise Ratio (Db)-75Db, Connector Type –Auxiliary , Material –Brass, Plastic. , Spotlight Wirelesspresentation Remote : Product Dimension -24X69x2.5 Cm: 49 Grams , Batteries – 1Lithium Polymer Batteries Required Hardware Platform –Pc, Compatible Devices –Projector, Laptop, Computer, Special Features-Bluetooth , Mounting Hardware – Presentation Remote, Proprietary Receiver User Documentationcharging Cable Pouch , Power Source –Battery Powered, Battery Description –Lithium- Ion Polymer, Battery Cell Composition –Lithium Polymer Connector Type –Bluetooth , Deptt. Of Geology , Tds Meter : Water Testing Kit, 0-9990 Ppm With Automatic Compensation , Ph Meter:Ph Tester Temperature & Water Quality Test , Digital Ec Meter: Water Testing Kit, 0-9990 Ppm With Automatic Compensation , Digital Thermometer: Steel Probe Professional Waterproof -Multicolour , Deptt. Of Library And Information Science , Trolley Speakers:Partyboxx310 Portable Bluetooth, Party Speaker 240W, Monstrous Pro Sound Dynamic Light Show Backlit Panel, Telescopic Handle And Wheels, Guitar & Mic Support Party Box App (Black) , Lcd Projector - Ultra X 35U, Display Type – Dlp, Brightness - 3000 Lumens, Resolution - 1024X768 Pixel, Throw Ratio - 1.5 ~ 1.65 M, Projection Size - 0.76-7.62 Mtr, Contrast Ratio - 22000:1, Computer Compatibility - Vga (640 X 480) To Wuxga (1920 X1200), Power Supply (Voltage, Hz) - Ac100 To 240 V, 50 To 60 Hz, Aspect Ratio - 16:9, Weight - 2.8 Kg, Projection Lamp- 210 W Zoom - 1.3: 1, Dimensions - 311.81 X 104.7 X 244.12 Mm With Ceiling Installation Bracket, Cable, Socket And All Accessories Pins. With All Installation Charges. And Screen Fitting On Wall , Deptt. Of Physical Education , Nine-Liter Wet Spiro Meter : This Academic-Quality Wet Spirometer Combines Reliability And Accuracy With An Increased Volume To Accommodate Students With Larger Lung Capacities., Large, Easy-To-Read Scale Graduations, Includes Disposable Mouthpieces And A One-Way Plastic Valve For Sanitary Classroom Use, Made Of Lightweight, Yet Durable, High-Density Polyethylene (Hdpe) Plastic And Aluminium. Determine Five Different Respiratory Volumes: Tidal Volume (Tv), Inspiratory Capacity (Ic), Inspiratory Reserve Volume (Irv), Expiratory Reserve Volume (Erv), Vital Capacity (Vc) , Emg Biofeedback Instruments: Emg Biofeedback Equipment Is Used For Controlling Ongoing Contraction And Relaxation Patterns. The Equipment Has Been Developed As Per The International Quality And Norms., It Highlights Awareness Of The Mechanism Of Muscle Flexure And Develops Voluntary Control Over Dysfunctional, Semi Voluntary Or Involuntary Muscle Activity., Uses: To Redress Disorder Related To Psychological, Psychosomatic, Stress , Vertical Jump System : Vertical Jump Training Measurement System, Specifications:Activity: Coaching, Training, Colour: Silver, Black, Red, Colourfamily: Multi Colour, Material: Metal, Product Height: 12 Ft., Product Type: Jump Training Accessory, Product Use/Compatibility: Measures Jump Height. , Multifunction Pedometer : Waterproof Full Colour Amoled Touchscreen, 0.95 Inch (2.41 Cms) Amoled Touch Large Colour Screen: Adjustable Screen Brightness, Dynamic And Vivid Display; Home Button Control, Belt Clip Design Makes Band Firmly Attached To Your Wrist., Spo2 Monitor-Spo2 Monitor Tracks Oxygen Saturation Levels In The Bloodstream So You Can Assess How Your Body Is Adapting During Workouts, Heart Rate Monitoring: Trueseen Allows 24-Hour Accurate Real-Time Heart Rate Monitoring And Warnings, On Standby Time Up To 14 Days And Saves Time On Frequent Charging, Multiple Sports Modes: Supports Outdoor And Indoor Run, Walking, Indoor And Outdoor Cycling, Pool Swim And Training Various Exercises Types, 5Atm 50 Meters Water-Resistant. Swimming Posture Recognition:, 6-Axis Sensor Recognizes Main Strokes, Records Speed, Distance, Number Of Turns, Calories, Average Swolf, And Other Data, Daily Activities Tracking And Monitoring: Step Count, Calories Burned, Distance Covered, Moderate To High-Intensity Activities Duration And Standing Status, Target Setting And Achievement Reminder , Force Plate Logger Sensor With Required Accessories : Dimensions: 11.2 X 10.7 X 2.4 Inches; 3.5 Kg, Height 2-1/2 Inches, Force Plate Logger Sensor For Measuring Constant And Changing Forces, Can Be Used To Study Newtons Laws Of Motion, Kinetic And Potential Energy, And Gravitational Force Strength For Further Research, Functions As Scale For Calculating Weight Or Pulling And Pushing Pressure, Experiment Duration Of 1.0 Second To 31.0 Days For Versatile Use, With 16 -Bit Analog-To-Digital Converter (Adc) Resolution For Reading Range Of Values, Accessories : A Usb Module (Usb 200) To Connect Via Usb Cable To Pc Or Mac, Or A Wi-Fi Module (Wifi201) And Battery (Bat200) To Connect To Any Wi-Fi Enabled Device (Smart Phone, Tablet, Computer) , Force Punching Plate With Required Accessories:Providing And Fixing, Dimensions: 12 X 11 X 2 Inches; 3.5 Kg, Force Plate Logger Sensor For Measuring Constant And Changing Forces, Can Be Used To Study Newtons Laws Of Motion, Kinetic And Potential Energy, And Gravitational Force Strength For Further Research, Functions As Scale For Calculating Weight Or Pulling And Pushing Pressure, Experiment Duration Of 1.0 Second To 31.0 Days For Versatile Use, With 16 -Bit Analogue-To-Digital Converter (Adc) Resolution For Reading Range Of Values, Accessories : A Usb Module (Usb 200) To Connect Via Usb Cable To Pc Or Mac, Or A Wi-Fi Module (Wifi201) And Battery (Bat200) To Connect To Any Wi-Fi Enabled Device (Smart Phone, Tablet, Computer) , Digital Back And Leg Dynamometer: For Measuring The Strength Of The Back And Leg., Dimensions: Approx.315(W) × 315(D) × 328(H) Mm, Weight: Approx. 3.7 Kg (Including The Weight Of The Handle), Automatic Stop: Approx. 1 Min After The Final Measurement, Power Source: Dry Battery Sum-4 × 2, Display: Lcd In 6 Digits, Range: 20 – 300Kg, Graduation: 0.5Kkg, Accuracy : +/-6.0Kg, Provides A Base For Sure Footing, A Large, Easy-To-Read Display And An Adjustable Hand-Grip Chain To Accommodate Height Differences.. Adjustable Chain, Accommodates Most Heights , Paraffin Wax Bath Heat Therapy Tub : Paraffin Bath Tub , Capacity : 5Kg, Power Plug : 220-240V 50/60Hz, Dimension:Internal S.S Tank Size: 40Cm X20cmx 20Cm., Heater: One Ring, 1000W , Heat Control: Thermostat To Control Temperature From 00 To 85 Degree, One Brush For Wax Application, One Mug, One Spatula, Aluminium Sheet Mesh For Heaters. , Human Skeleton Model : Pvc Alloy Material, Full Adult Size, Size : Height : 170 Cm, Height : 200 Cm (With Stand ) Weight: 15 Kg, Removable Arms And Legs, Breakage Free, Features Nerve Branches, Vertebral Artery And Hemited Lumbar Disc, Skull Includes Movable Jaw, Cut Caldarium, Suture Lines And Three Removable Lower Teeth, Mounted On A Sturdy 30Cm Wide Metal Base, Washable, Unbreakable Ideal For Teaching The Basics Of Human Anatomy , Interlocking Judo Matt : Made Of J.S.R( Japanese Synthetic Rubber), Size: 1Mtr × 1Mtr × 30 Mm, Judo Mat Density 200-250 , Deptt. Of Physics: , He-Ne- Lazer: 01Mw , He-Ne- Lazer: 05Mw , He-Ne- Lazer: 10Mw , Chemical Bath Deposition (Cbd) Instrument: The Set-Up Consists Of Following Units: Low Speed Light Duty Geared Stirrer, 1/20 Hp Ac/Dc Universal Motor,170 Rpm,S.S.Shaft With Chuck And Dimmer Stat Autovaries Speed Regulator.Cap.3-5Kgs With Stud & Backlit Assembly, To Hold Micro Slide Glass Digital Temperature Controller Model: Tc 544A, Selectron Make Display: 4 + 4 Digit, 7 Segment Digital Display, Timer: 0 To 9999 Min, Input: Fe-Con (J) / Cr-Al (K) Type Thermocouple, Range: 0 To 550°C, 1 Set Point, 230 V Ac Mains, 50 Hz, Crca Panel, Wiring & Temperature Sensor, Fe-Con (J) / Cr-Al (K) Type T/C, Max. Load: 2 Kw Heater Magnetic Stirrer With Hotplate Model: Ms203, Eltek Make / 2Mlh Remi Make Magnetic Stirrer, 2 Lit. Cap. Flask With Hot Plate Temp. Control, Step Less Speed Regulator & S.S.Body With Epoxy Coated Top Plate. Laboratory Jack (M.S.), Size: 8” X 8” Complete In All Respect , Thin Plates Thermoelectric Power Measurement Setup: Material:Mild Steel, Thickness: 0.1 Mm, Power: 50W, Display Type: Digital, Voltage230 V: Frequency 60 Hz , Electronic Spin Resonance And Nuclear Magnetic Resonance:Basic Unit Dimensions: 165X105x135 Mm3 Approx. Weight: 1.25 Kg Approx. Magnetic Coils Windings: 500 Each Magnetic Field: 0 - 3.37 Mt Connectors: Coaxial Power Connectors Dimensions: 20 Mm X 74 Mm Diam. Approx. Weight: 0.2 Kg Approx. Control Console Probe Input: 4-Pin Lemo Socket Coil Connectors: Saw Tooth Current Source, 0-250Ma, 50Ms, Pair Of Co-Axial Connectors Magnetic Output: Proportional To Coil Current, 0-1 V, Bnc Signal Output: Resonance Signal, 0-1 V, Bnc Socket Frequency Range: 45 To 75 Mhz Approx.(Esr) 10 To 15 Mhz Approx. (Nmr) Dimensions: 170X105x45 Mm3 Approx. Weight: 0.5 Kg Approx. Esr/Nmr Basic Set Includes A Basic Unit, Pair Of Coils, Control Panel & Plug-In Power Supply, 12 V Ac. , Potentionstat / Galvano Stat Instrument: (A)Potential Resolution: 1Mv (B)Potential Accuracy: +- 0.1% (C)Measured Current Resolution: 0.006% Ranges (A)Potential Range: +2~-2V(V) (B)Measured Current Range: 10-2~10-10 (C)Channels:2~10 Electrochemical Method (A)Cyclic Voltammetry (Cv) (B)Amperometry (It) (C)Open Circuit Potential (Ocp) Main Function (A)Multi-Channels With Individual Control Of 3 Electrodes System. (B)Multi-Channels Of Electrochemical , Operational Amplifier:(A)Potential Resolution: 1Mv (B)Potential Accuracy: +- 0.1% (C)Measured Current Resolution: 0.006% Ranges (A)Potential Range: +2~-2V(V) (B)Measured Current Range: 10-2~10-10 (C)Channels:2~10 Electrochemical Method (A)Cyclic Voltammetry (Cv) (B)Amperometry (It) (C)Open Circuit Potential (Ocp) Main Function (A)Multi-Channels With Individual Control Of 3 Electrodes System. (B)Multi-Channels Of Electrochemical , Digital Ph Meter: Range Ph Reading: 0 To 14 Mv Reading: -1250Mv To 1250Mv Solution Temperature: 0 To 100C Ambient Temperature: -40 To 70C (0C To 70C At Rated Accuracy) Resolution / Accuracy Ph Reading: 0.01 Ph 1 Mv Reading: 1Mv Solution Temperature: 0.1C 5 Ambient Temperature: +/- 2C 2 , Function Generator (1Mhz): Generator Frequency 1Mhz. O/P Voltage:1/10 Volt, Digital Display , Digitalvariable Power Supply 0-50Volt: Voltage 0-50Volt Current: 10Mv-1A Digital Display , Digitalvariable Power Supply 0-35V): Voltage 0-35Volt Current: 10Mv-2A Digital Display , Digital Multimeter: Hand Held Digital Multimeter With Four Display Digit With C Meter , (Dc+Acp-P) Power Chord, Two 30Mhz Oscilloscope Probes , Digital Storage Oscilloscope 100 Mhz: Signal Bandwidth : 100 Mhz Real Time Sampling:Max 1 Gsa/S Equivalent Sampling Rate: Max 50 Gsa/S 7.0 Tft Lcd Colour Display 2 Mpts Memory Depth , Rheostat 0-50 Ohm, 0-500Ohm, 0-1000Ohm: 0-50 Ohm, 0-500Ohm, 0-1000Ohm Cro (30Mhz): Bandwidthac 10Hz ~ 30Mhz (-3Db) Dc ~ 30Mhz (-3Db) Y Deflection 5Mv / Div ~ 20V / Div Rise Time <18Nsmag X 5 Accuracy : <5%Max Input400v(Dc+Acp-P) Sweep Mode Auto, Trig, Lock, Single Ac : 10Hz ~ 1Mhz -3Db Dc : 0 ~ 1Mhz -3Db Z Max. Input 400V , Resistance Decade Box 1-100K Ohm: , 8085 Microprocessor Kit : 8085 Microprocessor Training Kit Inbuilt Power Supply, 8085 Cpu Operating At 6.144 Mhz Crystal 8K Bytes Of Eprom Loaded With Powerful Monitor Program 8K Bytes Of Ram , Network Theorem Verification Kit (The Venin’S, Norton’S, Milkman’S,Maximum Power Transfer) , P-N Junction Diode Kit : 1) Vi Characteristics 2) P-N Junction Diode As A Wave Clipping Element , Zener Diodekit (Vi Characteristics) , Ujtkit (Characteristics And Application) , Scr Kit (Characteristics) , Study Of Amplifier Kit (Common Base/Common Emitter/Common Collector) , Jmfet Amplifier Kit (Characteristics) , Mosfet Amplifier Kit (Characteristics) , Multivibrators Kit (Actable, Bistable, Mons Stable Using Bjt) , Transistorized Oscillators Kit (Rc-Phase Shift, Wein Bridge, Hartley’S, Culprits) , Logic Gates Verification Kit (And, Or, Not, Nor, Nand With Ttl) , 7483 Bcd Adder Kit 7483 Binary Coded Decimal Adder , Binary Counters Kit Using Jkmsff , • Shift Registers Using Jkmsff Kit:74Hc 194 4-Bit Bidirectional Universal Shift Register. • Shift Registers Using Jkmsff Kit: 74Hc 198 8-Bit Bidirectional Universal Shift Register. , Multiplexer And De-Multiplexer Kit : (1:2, 1:4, 1:8, 1:16) Multiplexer (2:1, 4:1, 8:1, 16:1) De-Multiplexer , Counters Kit: (Synchronous, Asynchronous, Modulo N Decade) , Shift Registers Kit: (Sipo, Piso, Pipo, Siso) , P.A. System With Speaker, Mike And Collar Mike: Standard Company, Latest Version , Pa Mixer Amplifier 200 Watt With Integrated Digital Player (Bluetooth) And Wireless Microphone Connection , Wireless Professional Supercardioid Dynamic Microphone , Wired Dynamic Microphone With Cable And Stands , Collar Mic With 50-Meter Range , Cordless Gooseneck Microphone , Speaker 200W With Frequency Response :50-20000 Hz And Active & Passive Bluetooth With Stands Andtrapezoidal Enclosure Construction , Stage Monitor Speaker 200W , Teflon Lined Ss Hydrothermal Reactor 150Ml: Capacity-150Ml, Working Temp-2200C, Safe Temp. 2000C,Working Pressure:,3Mpa, Heating And Cooling Rate<5C/Min, Material: Shell Made Of High Quality Stainless Steel Inner Ptfe(Teflon Liner) Chamber , Deptt. Of Zoology: , Distilled Water Plant: Steel Distilled Water Apparatus With 5 Lit./Hr. Capacity , Shaking Incubator: I)Internal Volume: 215 Litreii) Platform Size: 580 Mm X 600 Mm Iii) Maximum Shaking :100Ml X 49,150Ml X Capacity (Volume X 49, 250 Ml X 33, 500Ml No. Of Flasks) X 24, 1000Ml X 15, 2000 Ml X 9 Iv) Shaking Speed Range: 20 To 250 Rpm V) Shaking Amplitude : 25 Mm Vi) Internal Dimensions : 660 X 765 X 650 W X D X H (Mm) Vii) Internal Dimensions : 800 X1150x1300 Wxdxh (Mm) Viii) Temperature Control : Microprocessor With Pt100 Sensorix)Display: 4 Lcd Screen, Large Size Display For Ease Of Reading X) Power Failure Alarm: Audio Visual Alarm Xi) Door Open Alarm : Audio Alarm In Case Door Open For Over One Minute Ii) Temperature Variation Alarm: Set Temperature ± 2°C, Audio Visual Alarm Xiii) Illumination: 8 Watts Fluorescent Tube Xiv) Internal Body Material: Stainless Steel – 304 Gradexv) External Body Material: Powder Coated Crca Steelxvi) Insulation (Cfc Free: 70 Mm Minimum For Body & 80 Mm For Door Polyurethane Foam)Xvii) Noise Level: Less Than 65 Db (A) , Laminar Air Flow (Horizontal) Mild Steel:Pre-Filter:99.00 % Down To 5 Micron Hepa Filter : Iso 14644 Class 5 (Class 100)99.97 % - 99.99 %Down To 0.3Micron Mesh Guard For Protection Of Hepa Filter Air Flow:Frontward Horizontally Noise Level:60 Decibel ± 5 % Velocity :0.35 – 0.50 M / Sec Work Table:Made Up Of Stainless Steel 304Gr. Cock For Gas On Work Table. Side Panels :6Mm ± 5 Mm Thick Acrylic Sheet. Front Door :Made Of Acrylic Uv Lamp:15/30 Wmake Philips Holland Illumination:20/40 Flourscent Tube Power Supply :230 V ± 10V /50 Hz Single Phase Cabinet : Made Of Mild Steel Duly Powder Coated Heavy Duty Blower : Dynamically Balanced With 0.25 Hp Electric Motor Mounted On Anti-Vibration Pad 1440 Rpm Motor Complete With Microprocessor Based Switches For Blower.Fluorescent Light And Uv Light With Lcd Back Light Display (Uv Light With Timer)Pressure : Digital Manometer 0.50 Mm Range With Filter Failure Alarm. Working Area Size:3’ X 2’ X 2’ , Colorimeter:Microprocessor Photo Colorimeter Model No. 1312 With 8 Glass Filters Covering Range Of 400- 700 Nm With Facility For Auto Concentration, %Transmission And Absorbance And K Factor Measurement. It Has 16X2 Line Lcd Data Display. Its Sample Holder Accommodates Glass Test Tubes Of 10Mm Path Length. Facility Has Been Provided For 100 Sample Data Storage And Interface For Any Centronics Printer. , Analytical Balance: The Brilliant Mono Tech Technology Sensormaximum Repeatability And Adherence To Uspoverload Protectionambient Condition Monitoring Perfect Self Automatic Calibrationprint Format Built-In Functioncapacity : 220Gmminimum Load : 10Mgreadability : 0.1Mgresponse Time : 2-3 Sec.Pan Size : 90Mm Dia , Dlp: Interactive Display Screen Size 75 Or Higher Resolution Uhd 3840 × 2160 Pixels Or Higher Brightness (Typical) 500 Nits Or Higher Contrast Ratio (Typical) 5000:1 Or Higher Response Time 4 Ms Or Better Light Life (Typical) 50,000 Hrs Or Higher Smart Eye Protectioninteractive Display Shouldhave Smart Eye Protection Hardness 4 Mm Tempered Ag Glass Or Better Anti-Glare Coating Interactive Display Should Have Anti-Glare Coating Touch Screen Touch Technology Infrared Touch Speaker Stereo Sound With In-Built 25 Watt X 2 Speakers And Subwoofer Of 20 Watt , Digital Photo Colorimeter: Range- 400-700 Nm, Filtre-8, Cuvete Size – 1 Ml • %T & Abs. • Display : 3 Digit Led • 1Ml Sample Volume • Light Source : White Led Eight Optical Filters On A Turret To Cover 400 – 700 Nm , High Speed Homogenizer:With 1/8 Hp Motor & Transformer Speed Regulator Suitable For Homogenizing Of Tissues At High Speed. Chuck To Hold Shaft Upto 50Ml Glass Homogenizing Cup With Rod Supplied As Standard. , Deptt. English , Cam Corder: Uvc Support Lcd/Evf Enhanced Visibility Usb, Type –C Usb Power Supply (Pd-Ei) Osd Recording Function 600 X Digital Sensor Size: 2.54 Cm Cmos, Autofocus System: Dual Pixel Cmosaf.Full Hd Recording Quality: Full Hd (1920X1080) 50 Pycc 420. , Deptt. Of Marathi , Pa System With 4 Speakers:Usb Amplifier - (Power Output 220 W Max., 160 W Rms At 10% Thd, 140W Rms At 5% Thd, 120W Rms At 2% Thd, Output Regulations 2 Db, No Load To Ful Load At 1Khz, Input Channels 5 - Mic 0.65 Mv/4.7%), 2 X Aux 100 Mv/470K, Frequency Response 50-15,000 Hz 223Db, Signal To Noise Ratio 60 Db, Tone Controls Bass: 710Db At 100 Hz, Treble 2210 Db At 10Khz, Output Ramp 200M V/6002, Line 1V/1Kil, Speaker Output, 42, 82, 70V And 100V, Digital Player Mp3, Player With Usb, Si) And Mmc Card Reader, Power Supply Dc: 24V (2 X 12V Car Battery) Ac: 220-240 V 50/60 Hz Power Consumption, Dc: 4A Ac: 300 Va. (In Set) Including Installation. , Collar Mic With 50-Meter Range , Television:138.8 Cm (55 Inch) Ultra Hd (4K) Led Smart Tv, Comprehensive Warranty:2 Yrs., Resolution: Ultra Hd (4K) 3840 X 2160 Pixels, , Deptt. Of Microbiology , Colorimeter:Digital Photoelectric Colorimeter With 8 Filters Lcd Read Out , Autoclave: Vertical, Size(30X50) With Basket, Spare Pressure Gauge, Rubber Gasket & Heating Coil , Hot Air Oven:(45X45x45) Cm, T.Range-5-250 Degree Celsius. Doubled Wall , Single Distillation Unit: Wall Mounted, Auto Cut Off, , Refrigerator: Side By Side Auto Defrost, 560-600 Lit. , Laminar Flow Bench: Ulpafilter, Iso Class 3 Work Zone, Low Noise At 52.4 Dba, Stainless Steel Side Wall, Internal Height: 2 Ft., Available Size: 4 Ft. , Incubator Bacteriological: Size(455X605x605)Mm,120Ltr. 5*To 70*Ambient Temperature, With Ss, 2 Shelves , Thermal Cycler :96 Well, Thermal Accuracy 35*C To 99.9*C,Dia.(44.5X24.5X21.5) , Adiwasi Girls Hostel , Setup & Installation Of Ip Dome /Bullet 2 Mp,1/2.8 Progressive Scan Cmos,Icr,Color 0.028 Lux @(F2.0:Agc On),0 Lux With Ir ,1920X1080:25Fps/30Fps (50/60Hz), 2.8Mm/4Mm Lens Fixed,H.265+/H.265/H.264/ Mjpeg, Dc12v &Poe, 3D Dnr, Blc, Roi, Hlc, Wdr, Ir Range: Up To 30M, Cloud Service. 3-Axis Adjustment, Rj45 Ethernet Interface, Line Crossing Detection, Intrusion Detection, Scene Change Detection, Audio Exception Detection, Face Detection, Ip67, Onvif (Profile S, Profile G), Isapi , Hard Surveillance Disk 6 Tb , Network Switch: 16 Port Network Switch Poe 16X10/100 Base-T Poe Port , 2 X Giga Rj45 , Network Switch:: 10 Port Network Switch Poe 8 X 10/100/1000 Base-T Poe Port, 2 X Giga Rj45 , Network Rack: 6U Network Rack With Standard Accessories , Pvc Junction Box , Metal Pole Clamp , Cat6 Cable (Rmt) , Cable Laying Charges (Rmt) , Conduit Pipe/Casing Patti With Pvc Clip Fitting (Mtr) , Setup,Installation ,Crimping ,Punching & Supervision Charges With One Year Warranty & Support , Deptt. Computer Science , N/W Multimedia Display Boards : Slim Digital Board Display 50” Hd And Nips High Quality Panels Commercial Grade Panels For 24/7 Usage Battery Power Multiple Usb Input Option – Usb ,Sd ,Hdmi Etc Built In Operating System With Wi-Fi And Sim Card Input Option High Brightness ( Sunlight Readable) Colour Coded Frame , Light Weight And Portable , Ups 500 Va:10Kva :Type: Online Ups 3 Phase In 3 Phase Out, Rating In Va: 10Kva, Battery Module: External Battery Module, No’S Of Battery: 20 Nos Of Batteries, Battery Type: Smf – Vrla, Dc Voltage:240 Vdc , Vacuum Cleaner:Wd X2 Wet And Dry 1300 Watts, 22.5 Kpa High Power Suction Vacuum Cleaner | Blower Function | Dynamic Dial Power Control | Auto Clean | 13 Accessories , Psychology , Wireless Microphone Awm-800U2 Dual Pa Microphones (Set) , Home Theatre:7200Watt, Dimension 16.93X1.93X8.27, Play Back Capacity, Weight 5.0716 2D-3D, Conversion Wi-Fi, Built In 2.4 Ghz, Input , Dlp Projector: Native Resolution —Wxga (1280X800) Or Higher. Brightness 4000 Ansi Lumens Or Better. Throw Long Throw, Keystone & Corner Correction - Projector Should Have Both Vertical (300) And Horizontal (200) Keystone Correction And Four Corner Adjustment, Minimum Lamp Life-15000 Hours In Economy Mode Input Ports- Hdmi-1, Vga-I. Audio In, Video X1 Other Ports-Rs 232, Lan (Rj45). Output Vga, Audio Out. Contrast Ratio- 22000:1 Or Better, Optical Zoom -1.1X, Throw Ration-1.55-1.70 Or Better, Special Features-Usb Reader. Data Over Lan. In-Built Speaker —Minimum 20 Watts Rams To Deliver Full Range Sound 20Hz-20Khz, Input Power Supply —As Per Indian Standard With Compatible Power Cable And Connector Accessories. All Device And Cable For Connecting With Computer. Remote Projector Should Be Supplied With Full Function Remote Control Having A Laser Pointer Inbuilt In The Remote Control, Otheraccessories —Cable9of 2 Meter Length Hdmi,Power0 Should Be Supplied Along With Projector, Bisregistration — Quoted Mode Of Projector Should Have Valid Bis Registration Make-Globus , Engineering Section (St-554) , Multifunction Photocopier Machine: Dadf, 25 Ppm, Print, Scan, Copy, Send Wifi Network, Machine Type A3, Monochrome Laser Mulification, Multiple Copies: Upto 9999, 2Gb Ram, 2 Cassette, 01 Byepass Tray, Duplex Print, Colourtouch Screen, Scan To E-Mail, Scan To Folder, Scan To Usb, Duplex Print, Duplex Scan Qr Latest Model Withstabilizer &Trolly.Ufr Ii Drivers, Ondemand Fixing Technology, Remote Operating Software Kit, Usb Host. , P.G.T.D. Of Physical Education , Dlp: Interactive Display Screen Size 75 Or Higher Resolution Uhd 3840 × 2160 Pixels Or Higher Brightness (Typical) 500 Nits Or Higher Contrast Ratio (Typical) 5000:1 Or Higher Response Time 4 Ms Or Better Light Life (Typical) 50,000 Hrs Or Higher Smart Eye Protection Interactive Display Shouldhave Smart Eye Protection Hardness 4 Mm Tempered Ag Glass Or Better Anti-Glare Coating Interactive Display Should Have Anti-Glare Coating Touch Screen Touch Technology Infrared Touch Speaker Stereo Sound With In-Built 25 Watt X 2 Speakers And Subwoofer Of 20 Watt
Contract Date: Aug 25, 2025 Contract Value : 59.16 Lakh
Boards / Undertakings / PSU No of Bidders 18
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 60,267
Government Departments No of Bidders 6
39.
Road Transport and Highways #7846168 AOC
Procurement Of C Class Items Under Rate Contract Mode Of Supply To Mtc For A Period Of One Year Procurement Of C Class Items For Leyland And Tata Vehicles And Other Items Required For Mtc Under Rate Contract Mode Of Supply To Mtc For A Period Of One Year , Auto Electrical Items: , Battery Terminal Bolt & Nut (Heavy Duty) , Battery Terminal Positive H/D Brass Coating , Battery Terminal Negative H/D Brass Coating , Battery Lug (Copper Heavy Duty) , Head Light Switch , Head Light Doom Dust Cover , 5 Head Light Ring , Square Parking Light Assembly For A/C Bus (Red) , Square Indicator Light Assembly For A/C Bus (Orange) , Square Reverse Light Assembly For A/C Bus (White) , Square Brake Light Assembly For A/C Bus (Red) , Registration Light (Number Plate) Assembly For A/C Bus , Red Colour Led Parking Light 4 Size , Red Colour Led Brake Light 4 Size , Orange Colour Led Indicator Light 4 Size , White Colour Led Reverse Light 4 Size , Front Indicator Light Assembly For A/C Vehicle , 10 Amps Piano Type Switch For Top Light Colour:White , 5 Amps Piano Type Switch For Top Light Colour:Black , Head Light Inner Ring Round Model P43 Type 7 Dia , Double Contact Wire With Fiber Washer And Spring , Single Contact Wire With Fiber Washer And Spring , Warning Lamp Assembly , Round Tube Light Transparent Acrylic Cover , Led Light System 1 1/4 X 55 Inner Top Light Cover Only , Led Light System 1 1/4 X 97 Inner Top Light Cover , Top Side Marker Led Assembly , Rear Brake Light & Parking Light Assembly Led-Red-5 Size , Front & Rear Indicator Light Assembly Led-Orange-5 Size , Reverse Gear (Rear) Light Assembly Led-White -5 Size , 12V Led Strip For 2 Feet Tube Light Assembly (240Led/Mtr) , Led Strip For 2 Feet 24V Tube Light Assembly (240Led/Mtr) , Foot Board Round Glass , Front Side Body Indicator Orange Led Light Assembly , Roof Top Marker Led Assembly , Dipper Switch Metal , Self Starter Switch , Side Indicator Switch (Toggle Switch) , Pull & Push Switch Heavy Duty , Head Light Outer Ring 7 Dia P43 Model Round Type , 24V Flasher Unit With Beeper (Musical Type) , Side Body Marker Light Led Assembly , 4 Pole Fuse Carrier , Indicator Light Assembly Orange Colour (Tata Model) , Parking Light Assembly White Colour- Heavy Duty , Parking Light Cover (White) Heavy Duty (Front Rectangular , Indicator Light Cover (Amber) Heavy Duty(Front Rectangular , Rectangular Type Light Cover Only (Four Chamber)-Heavy Duty , 3 Pin Type Head Light Holder For Halogen Bulb , Rectagular Type Four Chamber Tail Light Assy. With Ring , Tail Light Assembly (Yellow Colour) For Tata Small Bus , Tail Light Assembly (Red Colour) For Tata Small , Tail Light Assembly (White Colour) For Tata Small Bus , Blade Fuse Holder With 15Amps Fuse (Battery Fuse) Rbfh15 , 3 Fog Light Assembly For A/C Vehicle , Led Light System 1 1/4 X 55 Inner Top Light Cover Only , Led Light System 1 1/4 X 97 Inner Top Light , 16/15 Amp Piano Type Switch , 12V Flasher Unit With Beeper (Musical Type) For Small Bus , White Petroleum Jelly (One Kg.Packing Plastic , Transparent Cover For Bus Tube Light Size: 46 X 605 Mm , Front Indicator Cover Orange For Small Bus - Heavy Duty , Citee Horn Aph Hose Kit (3 Mtr. Hose With Adaptor) , Citee Aph Lever Switch For Air Horn, Make:Roots , Citee Air Horn Assembly Complete Set, Make:Roots , Blind Spot Mirror , Rear View Mirror Rrectangular Type (With Bracket Rod) , Rear View Mirror Round Type With Clamp Bolt &Nut Size:5.5 , Rear View Mirror Rod Set , Rear View Mirror With Clamp (Size: Length:390 Mm X Breadth 190 Mm) , Blade Fuse 15 Amps For Bsiii/Bsiv , Blade Fuse 30 Amps For Bsiii/Bsiv , Blade Fuse 5 Amps For Bsiii/Bsiv , Blade Fuse 10 Amps For Bsiii/Bsiv , 400 Amps Bed Fuse 1613 For Tata Bsiv , 40 Amps Bedfuse 1613 For Tata Bsiv-731309040 , 40 Amps Box Fuse 1613 For Tata Bsiv , 24V Ignition Relay (Lp1613) 5 Pin For Tata Bsiv , 12V Ingintion Relay 4 Pin For Tata Bsiv , 24 Volt Relay 430Amps (Wipper Sparking ) For Bsiv , 24 Volt Main 4 Pin Relay 50Amps (Head Light & Ignition) For Bsiv , 20 Amps Blade Fuse For Bsiv , 30 Amps Bed Fuse 712 , 30 Amps Box Fuse 712 , Main 4 Pin Relay 12V For Bsiii , Ignition 5 Pin Relay 24V For Bsiii/Bsiv , Tools And Plant Machinery Items: , 6308 Zz Type Bearing Make:Skf / Nbc , 6306 Zz Type Bearing Make :Skf , 6200 Zz Type Bearing Make:Skf / Nbc , 6304 Zz Type Bearing Make:Hch , 6208 Zz Type Ball Bearing Make :Skf , 6203 Zz Type Bearing Make :Skf , 6202 Zz Type Bearing Make:Skf / Nbc , 2.5Mm H.S.S. Drill Bit , 3.5Mm H.S.S.Drill Bit , Emery Sheet Rough 80 Grademake:Corporandam Universal , Emery Sheet Smooth 150 Grade Make:Corporandam Universal/ , 4 Roll Emery 120 Grade Make:Corporandam Universal/ , 3/8Bsf Tap Set(1 Set Of 3Nos , 14Mm Tap Set (1.5Mm Pitch) (1 Set Of 3 Nos.) , 5/8 Bsf Tap Set (1 Set Of 3 Nos.) , 12 X 1.75Mm Tap Set (1 Set Of 3 Nos.) , Tap Set 10 X 1.5 (1 Set Of 3 Nos.) , Boring Tool-Is 09-1616 Rh-P 30 Make:Miranda , Side Turning Tool-116-1616 Rh- K20 Make:Miranda , Side Turning Tool-116-1616 Rh - P30 Make:Miranda , V Turning Tool-163-1616 Rh-P30 Make:Miranda , V Turning Tool-163-1616 Rh-K 20 Make:Miranda , V Turning Tool-163-1212 Rh-K 20 Make:Miranda , Tip V Grade - Yg6 , Side Tool Grade - Yg6 , Hydraulic Jack Kit (8 Ton Capacity)(Major) , Spare Repair Kit (Cap.10 Tons) For Hydraulic Jack , Spare Repair Kit (Cap.12 Tons) For Bottle Jack , Hydraulic Jack Kit (8 Ton Capacity)(Major) , Grinding Stone Smooth (Size: 152X30x26mm) , Grinding Stone Rough (Size: 152X30x26mm) , Tool Grinding Stone (Green) Ccc60-K5-Ug 200X25x31.75 , 6 X 4 Grinding Stone Grade-(Silicon Carbide Cup Black Stone , Surface Grinding Stone Size: 150 X 80 X 25Mm , 8Mm Tap Set Make: Humma (1 Set Of 3 Nos.) , 80 Grid Round Emery Sheet Size:Dia 150Mm, 6 Holes , 6308 Zz Type Bearing Make : Nbc Or Fag Only , Grinding Wheel Rough Size: 200X25x31.75Mm , Grinding Wheel Smooth Size: 200X25x31.75Mm , 6205 Zz Type Bearing Make :Skf , 6305 Zz Type Bearing Make :Skf , 6204 Zz Type Bearing Make :Skf , 6206 Zz Type Bearing Make :Skf , 6307-Zz Type Ball Bearing Make:Skf / Nbc , Split Fire Stone 100 X3 X12.7 M A24-R5-Bfw , 1/8 H.S.S.Drill Bit (3.1Mm) Make:Bosch , 3/16 H.S.S.Drill Bit (4.7Mm) Make:Bosch , 13/64H.S.S Drill Bit(5.15Mm) Make:Bosch , 1/4 H.S.S.Drill Bit (6.3Mm) Make:Bosch , 5/16 H.S.S Drill Bit (8.00Mm) Make:Bosch , Single Pole 6 Way Rotary Switch 63A (Make:Jaibalaji) , Terminals 30 Amps Red (+) , Terminals 30 Amps Black (-) , Diode 40 Rb 60 Reverse , Diode 40 Nb 60 (Forwards) , Diode 40 Nb 60 (Reverser) , Diode 16 Ra 120 (Forwards) , Diode 16 Na 120 (Reverser) , Diode 40 Nb 120 (Forwards) , Diode 40 Rb 120 (Reverser) , 5 Hp 6-10 Amps Mk1 Relay Make: L & T , 3 Hpmk1 Contactor With400/440 Volt Coil Make: L & T , Push Button (On-Off) Make: L & T , Ammetre Round Type 30 Amp So-65 , Mk1 Screw (Starter Screw) Make: L & T , 10 Hp 13-21 Amps Ml 2/3 Thermal Over Load Relay , 10Hp Ml 2 3 Pole Contactor Wiht 415 Volt Coil Make: L & T , 10 Hp Ml2 415 Volt No Volt Coil Make : L & T , Mk1 Contactor Spares Kit Make : L & T , 10 Hp Ml2 Contactor Spares Ki , Limit Switch For Kre Washing Machine Make:Jai Balaji, , Scrubbing Brush 12 H/D For Floor Cleaning Use , 10Mm Drilling Machine Chuck Model:Gbm 10Re Make:Bosch , No.5 Letter Painting Brush Make: Camel , Paint Brush 38Mm , No.9 Letter Painting Brush Make: Camel , 2 Painting Brush Flat Make: Amar , 2 1/2 Painting Brush Flat Make: Amar , Welding Holder , Welding Shield Glass (Black) , Welding Shield Glass (White) , Carbon Holder Small , Brush Holder (Model:Gbm 10Re) , Advani K320 Welding Generator Regulator Assembly , Starter Bch Contactor 4 Pole 25Amps , Brush Plate , Carbon Brush Set , 20 Filter Housing (3/4 Treaded) , 20 Activated Carbon Catridge 5 Micron,Make:Belly, Felcon Or , Silex Size:4 X 8 (1 No. Consist Of 30 Kgs) , 20 Spun Filter For Ro Plant (Jumbo)-Pp5 Mic , 20 Wound Filter For Ro Plant (Jumbo)-Pp5 Mic , Cpa2 4040 Hydranautics Or , Activated Carbon Iv 600 , Electrical Contact Cleaner (Rust Remover) , Elgi Air Lube Xd Oil , 4Mm Carbide Drill Bit , 6Mm Carbide Drill Bit , 8Mm Carbide Drill Bit , 10Mm Id Air Hose With 330Bar W.P Suitable For Pneumatic , End Cover Packing For Car Washer Assembly (130660100010) , Suction Valve Spring For Car Washer Assy , Oil Filter For Elgi Screw Air Compressor , Connecting Rod & Crankshaft Assy Ts10 120Hn Model , V Belt B76 Ts10 120Hn Model Air Compressor , Top Ring , Suction Valve Seat , Delivery Valve Seat , Packing Ring For Car Washer Assembly , Tension Adjuster M16 X 75 , Hex Screw M8 X 25 , Connector , Oil Seal , Stepped Ring For 3Hp Car Washer Assembly , Slotted Oil Control Ring , Air Filter Element For Elgi Screw Air Compressor,En73s , Oil Filter For Elgi Screw Air Compressor, 25Lpm,En73s , M12x55 Stud , Plunger Housing , Safety Valve Assembly 3/8Bsp For Model Tc501 Air Compressor , B72 Belt V- Fenner Make For Tc500 Model Air Compressor , 1/2 X 3/8 Reducing Nipple , Cover Fly End For 3 Hp Car Washer Assembly , Cover Free End For 3 Hp Car Washer Assembly , M16 Nut(Hex) , Gland , Threaded Piece , A58 Car Washer Belt (Fenner Make:A3003-Fe602) , A 34 V Belt Fenner Make:Poly F/Plus , A51 Belt (Fenner Make:A3003-Fe532) , O2(Oxygen)Sensor For Nitrogen Plant , Cross Head , Gudgeon Pin With Circlip For Car Washer , Circlip , Drain Plug 3/8 Bsp , Stud M16 X 60 For Car Washer Assembly , Spring Washer M12 , 1/2Bsp X 10Mm Hose Connector , Controller For 10 Hp Screw Air Compressor , Distance Bush , 3/8Bsp X 10Mm Hose Connector , 50Mm Id Cylinder Liner Sleeve , 100Mm Id Cylinder Liner Sleeve , 70Mm Id Cylinder Liner Sleeve , 1 Rubber Hose (Working Pressure 15 Bar) Use For Automatic Bus Washing Machine , Base Assembley For Car Washer , End Disc Tc500 Air Compressor , Lipped Packing For Car Washer , Gun Assembly Brass , Plunger For 3 Hp Carwasher Unit , Breather Valve Assembly , Bottom Flange For Car Washer Assembly , Bottom Ring , Split Ring , Gun Nozzle , Dip Stick Plug , Gudgen Pin Plug 1 Bsp , Delivery Valve For Car Washer Assembly , Suction Valve For Car Washer Assembly , Delivery Valve Spring For Assembly , Belt Guard , Locking Piece For Car Washer Assembly , 60Mm Id Cylinder Liner Sleeve , Tyre Valve Pin Remover , Driving Pully Assembly , Air Seperator For 10Hp Elgi Screw Air Compressor , Oil Filter For 30Hp Kirlosker Air Compresssor. Kes2210 , Air Oil Seperator For 30Hp Kirloskar Air Compressor , Air Filter For 30Hp Kirlosker Air Compressor Kes2210 , Air Lube Oil For 30Hp Kirloskar Air Compressor , 127Mm Id Cylinder Liner Sleev , Air Lub Oil Suitable For Elgi Kirloskar Air Compressor , Carbon Brush Holder (Big 8 Nos) , Field Coil(Model:Gbm 10Re) , Torx Oval Head Screw M4 X 16 , Field 220-230V (Model:Gbm 13Re) , Stator 220-240V Model:Gbm 10Re , Armature Set 220-240V Model:Gbm 10Re , Spindle Assembly Model:Gbm 10Re , Armature Set 220-240V Model:Gbm 13Re , Switch Model:Gbm 13Re , Armature With Fan 220V (Model: Gws 8-100C) , Spindle Assembly Model:Gbm 13Re , Field (Model:Gws 8-100C) Make:Bosch , Distance Stud-B19 , Brush Pulley With Bolts-B18 , Mounting Block With Guide Pin Brush B16 With 15 , Motor Base Plate Three Phase Machine-B3 With 28 , Motor 3 Phase B2 , 10Mm Spiral Cable , Stem With Lock Eh5 , Flexible Shaft Grinder Inner & Outer Cable(15X2000mm) , Flexible Shaft Grinder Inner Outer Cable( M12x 2000Mm)-Metal , Stem Without Lock 20 , Bush Stitching Roller L & R Truck , Crank Case For 5Hp Air Compressor , Free End Cover 5Hp Air Compressor , Connecting Rod & Combined Crank Shaft Assy. For 5Hp , Fly End Cover For 5Hp Air Compressor (Model: Ts05120hn) , Piston Dia 90Mm For 5Hp Elgi Compressor (Model: Ts05120hn) , Cylinder Dia 90Mm For 5Hp Air Compressor (Model: Ts05120hn) , Piston Dia 50Mm For 5Hp Air Compresor, Model:Ts05120hn, , Intercooler For 5Hp Air Compresor, Model:Ts05120hn, , Cooling Fan And Pulley Assly For 5Hp Air Compressor , Connecting Rod & Crank Shaft With Bearing Assembly For 10Hp , Piston Assembly Dia 100Mm For 10Hp Air Compressor , Piston Assembly Ring Dia 100Mm For 10Hp Air Compressor , Cylinder Dia 100Mm For 10Hp Air Compressor, Model:Ts10lb-12 , Piston Dia 70Mm For 10Hp Air Compressor, Model:Ts10lb-12 , Obs Piston Ring Dia 70Mm For , Drive Impact Tool For Removing Field Coil Screw , 20Wound Filter For Ro Water Treatment Plant & Water , Membrane Cleaning Powder , 20Spun Filter For R.O Water Treatment Plant & Water , Anabond Anasteel (500 Gms) , Anabond -112 50Ml Pack , Grease Pistol Assy Make: Elgi , 2.2 Mtr Grease Hose Assembly , 3.3 Mtr Grease Hose Assembly , Radiator Descaling Powder , Decarbonizer & Degreasing Liq , Anabond-402 In 50Ml Packing , Filter Media(Silex) Size:2/4,4/8,8/16&16/32 , 20 Pp Housing Micron , P.U.Paste For Glass Fixing (600Ml)Make:Terostat 8590 , Glass Primer Make:Sika Primer 206 (G+P) (1 No Consist Of , O Hose Clip Stainless Steel , 6Mm I.D.Air Hose , 10Mm I.D.Car Washer Hose , Silicon Red Gasket Paste Super Flex 24Rtv Red 85Gm Pack , Steel Wire Brush (Plastic Handle) , Baniyanwaste (Cut Pieces) White Colour 4 X 4 , M-Seal90gm Packet , Leather Hand Gloves/Pair 16 , Soap Liquid For Glass Cleaning Make: Pril , Colour Cotton Yarn Waste In 50Kgs.Gross Wt. Packing , Cutting Blade (Small)Packet , Soap Liquid With Can (1 Litre Pack With Plastic Container) , Araldite 180Gm Tube , Tyre Air Gauge With Twin Connector With Hose Length , Air Oil Seperator For Elgi Screw Air Compressor , Air Filter Assy For Tc500 Model Air Compressor , Oil Level Indicator 1 1/4Bsp Tc500 000513441 For , Airpressure Gauge 0To25 Kg/Cm 2 (4Dia For Compressor) , Piston Ring Set 60Mm For Air Compressor Assembly Tc500 , 3/4 N.R.V.Assembly For Tc500 Air Compressor Assy , Key For Car Washer Assembly , 6 Rubber Packing Pad Make: Bosch 150Mm Dia , Automatic Lubrication System Spares: , 6Mm Spiral Cable (Or) Sleeve , 15Mm Spiral Cable (Or) Sleeve , 6Mm Secondary Hose , End - Connector Assembly M10 - 90Deg , End Connector Assembly M8 90Deg , End Connector Assembly M6 135 Deg , End Connector Assembly M6 90Deg , Compression Nut , Ferrule 6 Dia , Lock Nut M8 , 6Mm Lock Nut , Timer Unit Assy , Pump Element Assembly , Joint Connector , Assembly Wiring Harness For 24V Timer Unit , Assembly Wiring Harness Pump Assembly (Long) , Lock Nut M10 , Primary Hose Assy(2Mtr) , 12 Volt Convertor To 24 Volt , End Connector Assembly M8 Straight , Grease Nipple For Bsiii- M6*1 Straight (Joint Spider)- P4500129 , Grease Nipple (M10- V Type) For Leyland/Tata (Joint Spider)- F2932115 , Grease Nipple Straight 1/8 Bsf For Bsiii (Slack Adjuster) , Special Welding Rod: , Brass Flux , 1/8 Brass Welding Rod , Ewactrode Al2101 (Size: 3.15 Mm) , Ewactrode 670 (Size: 2.5 Mm) , Wunder 185 Wfc , Ewactrode St680 Steel Rod (Size: 3.15 Mm) , Wunder 660 Zh , Ewacpiercet Rode (Size: 3.15 Mm) , 1/8 M.S. Welding Rod , Exd 2800 , Metal Spray Powder, Eutalloy Powder, Ewac 1003 Ebz , Castaron 224 , Rewinding Spares: , 16 Swg S.E.Copper Wire Use For: Welding Machine , 22 Swg S.E.Copper Wire Use For: Car Washer Motor , 26 Swg S.E.Coper Wire Use For:3Hp Motor & Air , 28 Swg S.E Copper Wire Use For: Air Circulator , 29 Swg S.E. Copper Wire Use For: Air Circulator , 30 Swg S.E. Copper Wire Use For: Air Circulator , 32 Swg S.E. Copper Wire , 18.5 Swg S.E Copper Wire Use For: Welding Generator , 36 Swg S.E.Copper Wire Use For: Pedestal Fan , 37 Swg S.E. Copper Wire Use For:Celling Fan , 21 Swg S.E. Copperwire Use For: Air Circulator,Car , 27 Swg S.E.Copper Wire Use For:Pedestal Fan & Wall , 25 Swg S.E. Copper Wire Use For:1 Hp Motor & Krv , 17.5 Swg S.E.Copper Wire Use For: Welding Generator , 14 Swg S.E.Copper Wire Use For: 402 Self Motor , 23 Swg S.E.Copper Wire Use For: Air Compressor Motor And Kre Motor , 31 Swg S.E.Copper Wire Use For: Air Circulator , 24 Swg S.E.Copper Wire Use For: Jet Motor, Hp & Kre Motor , 19 Swg S.E.Copper Wire Use For: Car Washer Motor & Air Circulator , 20 Swg S.E.Copper Wire Use For: Car Washer Motor & Air Circulator , Soldering Tube Lead (60/40 Grade Tin:60% Lead: 40% Thick 16G , Soldering Flux (Paste) , Soldering Lead Stick (60% Lead, 40% Tin) , 10 Mills Millionex Paper , 7 Milis Millioxnex Sheet , 7 Mill Nornex Insulation , 3Mm Fibre Glass Sleeve Unvarnished , 4Mm Fibre Glass Sleeve Unvarnished , 2Mm Fibre Glass Sleeve F-Glass , 1Mm Fibre Glass Sleeve , Copper Wire Bare Strip Size:1.8X4.4Mm , Commutator-33 Segments Make:Abc (Or) Its Equivalent , Fiber Stamping - 23 Sgement Card Board , Copper Wire Bare Strip Size:4.4X2.2Mm , Commutator-23 Segment Make:Abc (Or) Its Equivalent , Fiber Stamping - 33 Sgement Card Board , Commutator 25 Segment Make:Abc (Or) Its Equivalent , Fiber Stamping - 25 Sgement Card Board , Dr.Peg Air Drying Varnish (900 Gram Nett Weight/1010Ml) , Gear Knob , 3 Core Wire (1.5 Sq.Mm) For Drilling Machine Purpose , 6Mm Pvc Sleeve , P.V.C. Cut Sleeve 16Mm , 10Mm Pvc Sleeve , 6Mm Fibre Glass Sleeve , 5 Mills Film Leatherold Sheet , Insulation Tape (25 Mtrs) Bule Colour Make:Amro Or Its Equivalent , Black Insulation Tape-Isi (9.144 Mtr Roll) Make:Deer , Led Route Board Spares: , Controller (4000 Route) Lcd Model , Digital Destination System Controller Consist Of Destination Display Board , Controller 4Ad Model Lines (Tamil Font Double Line) , Front Master Board 4Ad Model (1 No Per Vehicle) , Side & Rear Board 4Ad Model (2 No Per Vehicle) , Slave Board Green(Front&Side) (9 No Per Vehicle) Led , Slave Route Board Green Side (9 No Per Vehicle) Smd , Slave Route Board Red (3 No Per Vehicle) Smd Model , Mother Board (Side & Rear) , Controller For Route Board Smd Model , Sensor Card Smd Model , Dc-Dc Convertor 5V 20A (Font) Smd Model , Dc/Dc Convertor 12/24V-5V 20A (Front) Smd Model , Slave Board White (5 No Per Vehicle) Smd Model , Controller S-210(5000)Lines Led Model , Front Master Card Led Model , Side & Rear Master Card (2 No Per Vehicle) Led Model , Sensor Card For Rolls , U62 Card For Rolls , Slave Board Red (5 Nos/Bus) Led (Smd Model) , Controller For 3000 Lines For Led Route Board Item , Led Set Destination Board Boards With Control Panel , Front Master Board 4D Model , Rear Master Board 4D Model , Slave Board Red Rear ( 3 No Per Vehicle) Led Model , Slave Board White Front (5 Nos Per Vehicle) Led Model , Slave Board Yellow Front (5 Nos Per Vehicle) Led Model , Slave Board Red (Smd Model- 3 Nos Per Vehicle) , Front Master Board (1 No Per Vehicle) , Rear And Side Master Board (2 No Per Vehicle) , Controller (S210)-1 No Per Vehicle (4000 Lines) , Slave Board Green Led Model (9 No Per Vehicle) , Slave Board Green Smd Model (9 No Per Vehicle) , Slave Board Red Led Model (3 No Per Vehicle) , U62 Card (3 No Per Vehicle) Smd Model , Sensor Card Smd Model , Dc To Dc Converter- 4D Model (Input- 9V-32V) (Output-20 Amps -5 V) 2 No Per Vehicle , House Keeping Items: , Room Spray Make:Odnil Flavour : Lavendery Multi Flavour-220Ml , Kala Hit Lime Mosquito Spary , Wild Grass Broom Stick , Maap Stick , Plastic Mug , Odonil (Medium) (30 Days) , Toilet Cleaning Brush (Big) , Scented Phenoyle (Concentrate) , Flooring Mop , Floor Cleaner , Mosquito Sprayer (Lime/Lavender) , Room Spray (Premium Lavender Room Spary Multi Flavour-217Ml , All Out Refil (45 Days) , Wash Basin Cleaning Brush (Small) , Lizol Floor Cleaning , Hand Towel Small (White) , White Phenoyle (Dilute) (5 Ltr Cane) , Bleaching Powder , Dust Bin (Small With Cover) , 4 Ltr Plastic Bucket (Small) (For Toilet) , 20 Ltr Plastic Bucket (Big) , Napthalene Ball , Cleaning Acid , Brooms , Phynoil , Leyland A/C Vehicle Spares: , Compressor Bearing 3210 (5210-2Rs) , Compressor Oil (Bitzer Grade :Bse55) , R134a Floron Gas (10 Kg) , Blower Motor Make:Valeo , Condenser Fan Make:Valeo , A/C Suction Hose For R134a Gas (1.18X1w, W.P.500 Psi) (1 No Consist Of 9 Mtr, Cap & Crimping) , A/C Discharge Hose For R134a Gas (7/8X1w,W.P.785 Psi) (1 No Consist Of 9 Mtr, Cap & Crimping) , Liquid Line Filter Drier , A/C Compressor Bitzer 4Nfcy , A/C Compressor Shaft Seal , A/C Relay Board (Spheros) , A/C Dash Control(Spheros) , Low Pressure Switch (10 Psi) , High Pressure Switch (350 Psi) , Condenser Coil For Leyland A/C Vehicles , A/C Compressor Clutch Coil Assy , A/C Compressor Piston Rings -Is06622-1M2-70X1,5-Mc12/Po-38231022 , A/C Compressor Piston Rings -Is06622-1R-70X1,5-Mc12/Cripolf-38230055 , Bitzer Compressor Gasket Set 4Nfc/ 6 4Nfc/4Gfc-37283204 , Main Shaft Bearing , Expansion Valve (1 Set Of 2 Nos) (012-0062-00) , 24V A/C Control Panel For A/C Bus Make:Valeo , Inner Ceiling Ac Bottom Filter Length:137Cm, Breadth:40 Cm, Thickness; 1Cm , Inner Ceilling A/C Side Filter Length-135Cm Breadth:17.5 Cm, Thickness; 2 Cm , Wiper Motor Spares: , Circlip For Wiper Motor / Wiper Lock For Jnnurm Vehicle (1 Pkt Consist Of 10 Nos)-26710029 , Worm Wheel Double Gear (Ley)-26710548 , Gear And Slip Assy-26717023 , Gear Box Brush Box And Armature Assy-26719566 , Armature For Wiper Motor Leyland (24V)-26710525 / 26710900 , Wiper Motor Worm Wheel (Single Gear) , Brush Plate Assembly For Wiper Motor-26711972 , Wiper Miller , 4.5 Plunger For Wiper Use , 3.5 Plunger For Wiper Use , Wiper Arm 34 (Rh) For Red Bus , Wiper Blade 32 For Red Bus , Wiper Circlip For Red Bus , Wiper Kit (Rh) For Small Bus , Wiper Kit (Rh) For Redbus , Refilling Charges Of Gas: , Acetylene Gas Cylinder Gas Filling Charges (1No. Cylinder Consistof 6.0 Cu. Mtr. Gas) , Oxygen Gas Cylinder Gas Filling Charges (1No. Cylinder Consist Of 7.0 Cu. Mtr. Gas) , Nitrogen Gas 10 Ltr. Cylinder Gas Filling Charges (1No. Cylinder Consist Of 1.5 Cu. Mtr. Gas) , Oxygen Gas Cylinder (1No. Cylinder Consist Of 7.0 Cu. Mtr. Gas) , Nitrogen Gas 10 Ltr. Cylinder (1No. Cylinder Consist Of 1.5 Cu. Mtr. Gas) , Valve Gauge Manifold(1Bar To 24Bar And 1Bar To 30Bar) , Regulator For Nitrogen Gas (10 Ltr) Cylinder , Key For Nitrogen Gas (10 Ltr) Cylinder , Automatic Door Spares: , Door Cylinder Repair Kit For Red Bus 50Mm Bore Part , Male Elbow 6 X 1/8 , Outer Dia 6Mm Nylon Tube , Red Button , Green Button , 5/2 Double Acting Solenoid Valve Assembly 1/4 , 8Mm Y Connector , Seal Kit (Dia 50) (A12) , Spool Assembly , 8Mm L Connector , Door Cylinder Shaft Oil Seal (Pneumatic U Seal 20X28x6.3Mm) , Dust Seal For Door Cylinder , T Connector 8X8x6mm , Door Yoke With Pin , Male Connector M22x1.5 For Door System , Door Cylinder Assembly , Male Clevis Dia-50Mm , Hand Lever Valve 1/4 X 5/2 , Male Elbow 1/4 X 6Mm Outer Dia , Flow Control Valve 1/4 X 6Mm , Pu Tube 6Mm Outer Dia , Union Tee 6Mm , Straight Union 6Mm , Union Tee 8Mm , Male Elbow 1/4 X 8Mm , Straight Union 8Mm , Gyratory Ball Joint , Pull Push Valve 1/4 - 3/2 (Door Emergency Switch) , Door Roller (Leyland) Assembly 32.0 Outer Dia , Door Hinges With Out Handle Heavy Duty , Door Hinges With Handle Heavy Duty , Door Mounting Bracket With Pin , Door Piston Mounting Bracket , Body Building Items: , New Model Mtc Left Side Cowl , New Model Mtc Right Side Cowl , New Model Mtc Centre Door Set (1 Set Of 2 Nos) , 2Mm Plasofal Felt-20Mts/Roll 1 Meter Width Above 40Kgs/Roll , Fevicol Sr998 1 Lts. Container. , 6Mm Steel Plate 8 X 4 Size , 3Mm Pvc Ac Sheet (Red) 1 Foot Width (Curtain Safety Guard) , Hinges 40Mm , Aluminium Tower Bolt Length-6 Plunger Dia - 12Mm , Hinges 3Mm X 75Mm Length , M.S.Hinges 4 , Flock Channel 25 X 15 X 15 X 2Mm 1.16 Mtr , Others: , Tappal Clip Pad (Tulasi) , Carbon (Pencil Special)Blue , Eraser (Pencil)Nataraj , File Pad , Gum (Small) 150Ml Container , Jute (3 Ply) Each 5 Kg Packing , Pin Box Bell Brand , Pencil Black Led. , Transparent Polythene Cover , Sealing Wax 8 Sticks In A Box , Stapler Pin No.10-1M(1000 Pins , Stamp Pad (Big)-Metal , Stamp Pad Ink (60 Ml) , Thread (Simco) No:55 , 6 Tag With Sharp Edge(Uom:1 No , Kraft Wrapper Sheet 48Kg. , Chalk Box (White) 140 Nos.Per , Plastic Folder For Retd. , 1.5 Cello Tape (Big) , 1 Cello Tape (Big) , A4 Size Transparent L Folder , Uniball Pen (Royal Blue) , Uniball Pen (Green) , Uniball Pen (Black) , Temporary Board Marker (Blue) , Temporary Board Marker (Black) , Temporary Board Marker (Green) , Temporary Board Marker (Red) , Permanent Board Marker (Black) , Permanent Board Marker (Blue) , Permanent Board Marker (Green) , 2 Cello Tape (Big) , 3 Cello Tape (Big) , 3 Brown Tape (Big) , Cd Marker Pen , Cable Tag 6 (Colour : White) , Gluestick , Cable Tag 10 (Colour : White) , Cable Tag 12 (Colour : White) , Cable Tag 8 (Colour : White) , Stapler Pin Suitable For Pneumatic Gun Make:Kaymo-St8006 , Polythene Bag (Above 51 Microns /Bio-Degradable) Size:10*10 , Polythene Bag (Above 51 Microns /Bio-Degradable) Size:16*14 , Bosch Non Proprietary Fip Spares: , 19Mm Banjo Bolt-370 For Bsiii/Bsiv -9411033404 , 19Mm Banjo Copper Washer For Bsiii-2916710609 , Feed Pump Gasket For Bsiii-F002a11261/P1300317 , Fuel Pump Delivery Valve Plastic Cap 14Mm For Bsiii-94310311300 , Automizer Plastic Cap For Bsiii , Feed Pump Protection Cap (B&C)-2433335669 , Banjo Bolt (M16x1.5)For Bsiii/Bsiv- X3105115 , 17Mm Thick Banjo Bolt For Bsiii- 3413455044 , 17Mm Thick Banjo Copper Washer For Bsiii Od-17Mm, Id-10Mm Thick-1Mm -2916710607 , 19Mm Copper Washer For Bsiii/Bsiv Od-18.9Mm,Id-14Mm Width-1.5Mm , Leak Off Pipe Banjo Washer For Bsiii-P1302249/P1313635 , 6Mm Aluminium Washer For Bsiv , 10Mm Aluminium Washer For Bsiv , 14Mm Aluminium Washer For Bsiv , 16Mm Aluminium Washer For Bsiv , 8Mm Aluminium Washer For Bsiv , Over Flow Adoptor T Type(Metal) For Tat Bsiv/Small Bus , Over Flow Adoptor L Type (Metal) For Tat Bsiv/Small Bus , Oring For Over Flow Adoptor For Tata Bsiv /Small Bus-F1761300/P8101117 , Engine Cooler Plate Dummy O Ring For Bsiii/Bsiv/1611-F2749700 , Automizer Seating Washer For Bsiii-F1761300/P8101117 , Automizer Seating Washer For Small Bus & Tata Bsiv , Valve For Feeder Pump For Bsiii-2443203001 , Radiator Spares: , Radiator Top Tank For Bsiii-B2618139/P2618139 , 3 Way Pipe For Bsiii- F8600214 , Radiator Upper Tank Plastic For Bsiii , Radiator Lower Tank For Bsiii , Radiator Core Oring Radiator Tank Packing Bsiii Leyland & Tata (L=22Xb=2.5) , Radiator Top Tank Deareation(6.5 Ltr Capacity For Bsiv) -F1002600 , Radiator Upper Tank Plastic (Tat Toyo) For Bsiv , Radiator Lower Tank For Bsiv , Radiator Plastic Upper Tank (Alcraft) For Bsiv , Radiator Plastic Bottom Tank , Radiator Coreoring(Radiator) (Alcraft) For Bsiv , Radiator Plastic Upper Tank For Small Bus , Radiator Plastic Bottom Tank For Small Bus , Radiator Upper Tank Bolt Type (Alcraft) For Leyland Bs Iv , Radiator Plastic Upper Tank For Tata Bsiv , Radiator Plastic Bottom Tank For Tata Bsiv , Radiator Plastic Upper Tank For Tata Lpo1515 , Gear Linkage Items: , Clutch Pedal Tread Plate For Bsiii/Bsiv/Vk1611-F3030250/F3030950 , Clutch Clamping Ring (Outer Die) For Bsiii/Bsiv/Vk1611-F3130015 , Spherical Seating Washer (Inner Die ) For Bsiii /Bsiv /Vk1611- F0950015 , Speed Change Leverl Housing For Bsiii F1831022 , Clutch Fork Bush For Bsiii/ Bsiv-F0530311/F0530522 , Clutch Fork Pin For Bsiii/Bsiv/Vk1611-F0918315/F0932815 , Fulcrum Pin For Bsiii/Bsiv-F0915015 , Bimetal Bush For Bsiii/Bsiv-F0534230 , Pull Of Spring For Bsiii/Bsiv/Vk1611-F3630910 , Brake Pedal Pivot Pin For Bsiii/Bsiv/Vk1611-F0952315 , Brake Pedal Sleeve For Bsiii/Bsiv/Vk1611-F3430515 , Extended Outer Lever Z Link For Bsiii-F2417911/F9h01011 , Pivot Pin Pedal Cotter Pin For Bsiii/Bsiv/Vk1611-F0937615 , Clutch Pedal Bush For Bsiii/Bsiv/Vk1611-F0530015 , Clutch Rod Yoke (Jaw End) For Bsiii/Bsiv/Vk1611-F2130111/F2131111 , Z Yoke Outer For Bs1v/Vk1611-F09h01111 , Selector Housing Repair Kit For Bsiii-P5105336 , Ball Piller For Bsiii/Bsiv-F0900810 , Gear Box Ball Joint Right M18x1.5 For Bsiii /Bsiv/Vk1611-F8350800/F7406600/114097082/124097102 , Gear Box Ball Joint Left M18x1.5 For Bsiii/Bsiv/Vk1611-F8350700/F7406700/114097072/124097092 , Gear Box Ball Joint Nut M12x1.5 Nylock Nut For Bsiii/Bsiv/Vk1611-918123110/L3621218 , Outer Lever For Bsiii-F2413111 , Lucas & Bosch Non Proprietary Electrical Spares: , Bush Set For Bsiii/Bsiv Bosch Self Starter Mico-2000301000 , Brush Gear (Mico) For Bsiii/Bsiv Self Motor-F002g20813 , Commutator End Bush (Mico) For Bsiii/Bsiv Self Motor , Centre Plate Bush (Mico) For Bsiii/Bsiv , Front Bush 1St Over Size (S.S) , Front Bush 2Nd Over Size(S.S) , Centre Bush 1St Over Size(S.S) , Centre Bush 2Nd Over Size(S.S) , Ce Bush 1St Over Size (S.S) , Ce Bush 2Nd Over Size (S.S) , Front Bush(3Rd Over Size) For Selfmotor Use , Centre Bush (3Rd Over Size) For Self Motor Use , Ce Bush (3Rd Over Size) For Self Motor Use , Carbon Brush For Small Bus Alterbnator (Mico) , Slip Ring For Small Bus Alternator (Mico) , Connecting Plug For Small Bus Alternator-F002g10230 , Malleable Components: , Front Spring Ibolt With Nut Length-228 Mm For Bsiii/Bsiv Vk1611 , Front Spring I Bolt 242Mm With Nut For Bsiii/Bsiv/Vk1611 , 3/4 Bsf Simmonds Nut (I Bolt Use) For Bsiii/Bsiv/Vk1611 , Centre Bolt With Nut For 3 Wevellor Front Spring L=8 As Per Sample For Bsiii , Rear Spring Ubolt M22 X 2.5 (M22x2.5X65x400) For Bsiii/Bsiv /Vk1611 , Rear Spring U Bolt Nut M22 X2.5 For Bsiii/Bsiv/Vk1611 , Spherical Washer For Bsiii/Bsiv , 4Th Leaf Front Spring Bracket Assembly-2 1/2X3 Rivet-2Nos Bolt & Nut With Sleeve , 7Th Leaf Front Spring Bracket Assembly-4X3 Rivet-2 Nos Bolt & Nut With Sleeve , 4Th Leaf Rear Spring Bracket Assy-2 1/2X4 Rivet-2 Nos Bolt & Nut With Sleeve , 9Th Leaf Rear Spring Bracket Assy-2 1/2X4 Rivet -2Nos Bolt & Nut With Sleeve , Front Spring Centre Bolt With Nut For Bsiv , Front Spring I Bolt For Bsiv (268Mm ) With Nut , Front I Bolt Nut For Bsiv , Front Spring Centre Bolt With Nut M12x180x11 For Tata Bsiv , Rear Spring Centre Bolt With Nut M12x180 For Tat Bsiv , Bimetalic Bush For Tata Front Spring Main Leaf-277032103401 , Bimetalic Bush For Tata Rear Spring Main Leaf-277032204203 , Front Spring U Clamp With Nut For Tata Bsiv-2770322204203 , Rear Spring U Clamp With Nut For Tata Bsiv-259932504201 , Front Spring Centre Bolt With Nut For Weveller Spring Length-170.5Mm,Dia14mm Head 30Mm , Rear Spring Centre Bolt With Nut Length-150.5Mm Dia-14Mm, Head-10Mm , Front Spring Bracket Bolt 109Mm X9x18 Tpi For Bsiii /Bsiv/Vk1611 , Rear Spring Bracket Bolt With Nut 142Mmx10x1.5Mm , Front Shackle Pin For Small Bus -265132106704/264032106701 , Rear Shackle Pin For Small Bus-264032406702 , Front Spring Shackle Assembly With Bush For Small Bus -264032100105 , Rear Spring Shackle Assembly With Bush For Small Bus -264032400106 , Bimetalic Bush For Tata Small Bus Front Spring Main Leaf-265132403401 , Bimetalic Bush For Tata Small Bus Rear Spring Main Leaf-551232103402 , U Clamp Rear Spring With Nut For Small Bus-282132504202 , Front Spring U Clamp With Nut For Tata Small Bus , Front Rear U Clamp With Nut For Small Bus , Rear Rear U Clamp With Nut For Small Bus -264432504205/12052396067 , Silencer & Muffler Assembly: , Insert For Bsiv/Vk1611 , S/A Of First Pipe For Bsiv , Muffler Assembly For Bsiv , S/A Of First Pipe For Vk1611 , Tail Pipe For Vk1611 , S/A Of Muffler For Vk1611 , Front Exhaust Pipe Assembly With Flexible Bellow For Small Bus -264249100103 , Silencer Assembly For Small Bus -264349100112 , Silencer Flexible Bellow Hose For Tata Small Bus , Hoses: , Fip Rubber Hose (Fuel Filter To Pump)(M17 Dia M19 ) For Bsiii , Rubber Ended Nylon Hose For Return Line For Bsiii , Fuel Hose (M19 Dia M19) For Bsiii , Fuel Hose Stainer To Feed Pmp For Bsiii , Fuel Main Hose (Tank To Strainer ) For Bsiii , Leak Off Pipe For Vk1611(Rubber Hose) , Fuel Return Line (Over Flow Hose ) For Bsiv , S/A Pipe Inlet Main Fuel For Bsiv , S/A Pipe Outlet Main Fuel For Bsiv , Fuel Over Flow Pipe-Common Rail Of Fip(M19 Dia M22) Id 10Mm For Bsiv , Over Flow Hose Fip To Diesel Tank (M19 Dia M22) 5 Mtr For Bsiv , Diesel Main Hose-Feeder Pump To Tank-27 Adopter (Tank Side) For Bsiv , Fuel Hose - Hand Primer To Pre Filter For Bsiv , Turbo Return Hose (Turbo To Sump) For Tata Bsiv /1613 , Fuel Line Assembly Baby Filter To Water Separator (Lp1613)-216547600151 , Fule Line Assembly Water Separator To Engine (Lp1613)-216547600153 , Fuel Line Assembly Overflow Engine To Tank Lp1613-216547600152 , Diesel Hose (Diesel Oil Filter)-278607996948 , Fuel Hose(Diesel Oil Filter)-278607996949 , Fuel Line Assembly Tank To Water Separator Lpo1515-207347600183 , Fuel Line Assembly Water Separater To Engine Lpo1515-207347600185 , Fuel Line Assembly Over Flow Lpo1515-207347600184 , Power Steering Suction Hose (Reservoir To Pump) For Bsiii , Power Steering Pressure Hose (Pump To Box) For Bsiii/Bsiv , Power Steering Suction Hose (Reservoir To Pump) For Bsiv/ , Power Steering Pressure Hose (Pump To Box)For Bsiv/1611 , Power Steering Suction Pipe Assembly (Tank To Pump) Tata , Power Steering Pressure Pipe Assembly (Pump To Steering , Power Steering Return Pipe Assembly (Box To Tank) For , Power Steering Suction Hose , Power Steering Pressure Hose , Power Steering Return Hose For Tata Small Bus-28214800143 , Air Pressure Gauge Hose Rough Thread For Bsiii , Air Pressure Gauge Hose Fine Thread For Bsiii , Air Hose 12Mm-2Mtr Length Relay Valve To Air Tank(One Si , Air Hose 12Mm-7Mtr Length(Foot Valve To Air Tank)(One Side , Air Hose 12Mm-3Mtr Length D.D.Unit To Air Tank(One Side , Hand Brake Hose 12Mm-5Mtr Length(One Side Straight Other , Hand Brake Hose 12Mm-7Mtr Length(Both Side L Bend Conn , Air Hose 12Mm -8Mtr Length (One Side Straight,Other Side , Air Hose 12Mm-10Mtr Length (Both Side L Bend Connector , Air Hose 12Mm-10Mtr Length (One Side Straight,Other Side , Air Compressor Coolant Outlet Hose (Length) For Bsiv/161 , Air Compressor Coolant Inlet Hose (Short) For Bsiv/1611 , Egr Coolant Inlet Pipe For Al Vk1611 (Red Bus)-B2g01415 , Egr Coolant Outlet Pipe For Al Vk1611 (Red Bus)-B2g01416 , Air Hose 12Mm-2Mtr Air Dryer To System Protection Valve For Al1611 (O-S/B) , Air Hose 12Mm-1Mtr System Protection Valve To Air Tank For Al1611 (O-S/B) , Air Hose 12Mm-3Mtr System Protection Valve To Auxilary For Al1611 (O-S/B) , Air Hose 12Mm-5Mtr System Protection Valve To Flick Valve For Al1611 (B/B) , Air Hose 12Mm-5Mtr Air Tank To Foot Valve For Al1611 (O-S/B) , Air Hose 12Mm-7Mtr Foot Valve To Rear Air Tank For Al1611 (O-S/B) , Air Hose 12Mm-1Mtr Rear Air Tank To T Connector For Al1611 (B/B) , Air Hose 12Mm-1/2Mtr Relay Valve To T Connector For Al1611 (B/B) , Automoizer Leak Off Pipe For Tata Bsiv , Air Hose 12Mm - 5Mtr Length (Dd Unit To Air Tank)- Both Side L Bend , Air Compressor Oil Lube Line Hose Length-550Mm/10Mm Banjo For Tata Bsiv-252518130162 , Air Compressor Oil Lube Line Hose Length-450Mm/10Mm Banjo For Tata Bsiv-252518170128 , Oil Compressor Return Hose For Tata Bsiv-252523145807 , Air Compressor Hose For Tata Bsiv-263243910143 , Tata Red Bus Water Pump Spares (Lp 1515) , Water Pump Metal Impeller For Tata Lpo1515 , Water Pump Oil Seal For Tata Lpo1515 , Water Pump Shaft With Bearing For Tat Lpo1515 , Water Pump Major Repair Kit For Tata Lpo1515 , Circlip, Shim, Adapter,, Filler Cap, Dip Stick, Accelerator Pedal Roller Kitand Drain Plug , Crank Case Drain Plug With Washer For Bsiii/Bsiv , Radiator Drain Plug For A/L Bsiii/Bsiv/Tata Bsiv , Differential Breather For Bsiii/Bsiv 1611 , Crank Case Drain Plug Washer For Bsiv/1611-Fl800231 , Crank Case Drain Plug Magnetic For Bsiv/1611-F3114515 , Rear Hub Shim-K121180/F4430610 , Engine Oil Dipstick For Tata-252701170172 , Engine Oil Dipstick With Guide For Al1611-B6e04801 , Front Hub Cup Fine Thread For Tata Bsiv/Small Bus-257433403703 , Diesel Tank Cap For Bsiii-F1133942/B5002203 , Urea Filler Cap (Adbule Tank Cap)-F4l00700 , Assembly Fuel Tank Cap For Tata Small Bus-0424700605J , Circlip For Spider Kit (Joint) For Bsiii/Bsiv Make:Lako , Circlip For Spider Kit(Joint) For A/L/Tata Bsiv (Big Size) , S Cam Shaft Circlip For Bsiii/Bsiv Make:Lako , Scam Shaft Circlip For Small Bus/Tata Bsiv Make:Lako , S Cam Shaft Oil Seal For Bsiii & Bsiv/1611 , SCam Shaft Shim 1Mm Thickness For A/L Bsiii & , King Pin Shim 1Mm Thickness For A/L Bsiii & Bsiv , King Pin Shim 2Mm Thickness For A/L Bsiii & Bsiv , Washer-S-Cam Shaft For A/L Bsiii & Bsiv , Shim For Propeller Shaft (Spider Kit)Al1611-Dia-41Mm, , Shim For Propeller Shaft Alps 44/32 (Spider Kit)For Bsiii , Front Hub Shim Thin Type (0.75Mm) For Bsiii/Bsiv , Front Hub Shim Thick Type (1Mm) For Bsiii , King Pin Shim 0.5Mm For Tata Small Bus , King Pin Shim 1Mm For Tata Small Bus , Radiator Cap With Chain Stainless Steel)(0.9 Ksc)Pres , Engine Oil Dip Stick For Bsiv , Engine Oil Dip Stick Guide For Bsiv , Fuel Tank Cap For Al1611 , Valve Door Cap (Nylon White) For Bsiii/Bsiv , Engine Oil Dip Stick For Tata Bsiv , Front Hub Cup Rough Thread For Tata Bsiv/Small Bus , Valve Door Cap(Cylinder Head Cover) For Tata Small Bus , Accelerator Pedal Roller Kit For Bsiii/Bsiv/1611 , Air Dryer & Ddu Adaptor For Al1611 , Air Tank Drain Plug Aluminium Washer 22Mm For Bsiii , Drying Distribution Unit Aluminium Washer 16Mm For , Dual Brake Valve (Foot Valve) Low Pressure Switch Dummy For , Dual Brake Valve (Foot Valve) Low Pressure Switch Dummy , Air Tank Drain Plug Rubber O Ring For Bsiii/Bsiv , Engine Oil Level Gauge Dipstick For Bsiii-138250105 , S-Camshaft O Ring (Front And Rear) For Bsiii & Bsiv-F2710400 , Automoizer Rubber Bed For Bsiii-X20702000 , Clutch Spares: , Clutch Oil Reservoir Tank For Tata Small Bus-264129100173 , Clutch Withdrawal Plate Assembly For Tata Bsiv , Clutch Withdrawal Plate Assembly For Tata Lpo1515
Contract Date: Aug 22, 2025 Contract Value : 28.76 Lakh
Government Departments No of Bidders 15
40.
Shipping #7834986 AOC
Tender For Repairs To Type B Qtrs - 22 Nos At Headland; 1 Dismantling and clearing of cement concrete of waterproofing ..etc. in trap stone metal without causing any damage to the structure, clearing the dismantled materials and stacking within a lead of 100 m including all lift , cleaning surface, etc. as directed. All labour and material, tools & plant etc. complete. 2 Removing existing plaster carefully by Stripping clearing away the same at places pointed out within a lead of 100m, cleaning the surfaces etc. As directed. All labour & material, tools & plant etc. complete. 3 CC (1:11/2:3) mix using 20mm graded black trap stone metal out of quarried boulders as coarse aggregate , including mixing, placing, consolidating, vibrating, levelling, curing etc. but excluding the cost of shuttering and reinforcement. All labour & material etc. complete. 4 RCC jally of any approved pattern/design with CC (1:2:4) mix using 10mm graded aggregate, average 5 cm thick precast members reinforced with 6mm dia M.S./torsteel reinforcement bars including all shuttering, tying and placing of reinforcement and keeping the same in position, mixing, placing, consolidating, curing and finishing with C.M.(1:3) 6 mm thick all shuttering work, cost of steel reinforcement and fixing the jally in position with cement mortar 1:3 etc. all labour & material etc. complete. 5 Floor finishing with C.M.(1:3) 15mm thick (av) including mixing, finishing smooth with cement slurry, thread lining curing, adding colour/Redoxide..etc. etc. All labour and material etc. complete. 6 Finishing cooking platform with 25mm thick polished cudappa stone slabs over 20mm thick C.M.(1:6). including polishing with black polish All labour & material etc. complete. 7 Providing flooring with ceramic tiles Ist quality of approved make laid over 12mm thick C.M. (1:3) including cleaning,curing etc. All labour & material, tools & plant etc. complete. 8 Providing skirting/dadooing to the required height with best quality ceramic tiles spartek or equivalent quality set over a base of cement mortar (1:3) 10mm thick including cutting the tiles where required necessary specials, pointing, curing etc. All labour & material complete. 9 Sealing the cracks in walls, RCC members etc. by use of scaffolding or Jhulla for the crack width up to 20 mm using suitable crack fill material of cement and fine quartz sand putty including` necessary addition of chemical in the proportion of 1:1 or as per manufacturers instruction, properly grouting into cracks after necessary cleaning including applying two coats (100 mm width) of Polyalk WP of approved brand over sealed crack or as directed etc, including removing the roots of plants and grown vegetation. All tools, plants, labour and materials etc. complete (Payment shall be made in running meter of sealed crack). 10 Thorough cleaning of the exposed steel, removing the scales and rust with wire brush and emery paper and applying suitable chemical viz. Rusticide,Rust converter, Zentrifix KMH or equivalent, approved in two coats as per manufacturers specification as and as directed , providing additional bars if required as per existing diameter bar as main reinforcement/ stirrups for beams, columns /chajjas including welding of bar/tying or by ensuring shear connectors to the reinforcement (Reinforcement to be measured under Item no. 19) by drilling holes to beams for anchoring shear connectors ( to be measured under item for drilling and fixing shear connectors), etc. and securing the bars in position etc. but excluding the cost of steel reinforcement. All tools, plants labour and materials etc. complete. 11 Providing and applying Rust passivator primer NitoZinc of FOSROC or any other approved in ratio as per manufacturers specification after cleaning the existing surface from dust/ loose particles by applying air by air blowers under pressure etc. All labour and material etc complete as directed. 12 Providing and applying bonding agent in ratio of 2:1 by wt. of Sun epoxy 358,Hack aid plus,plyalk EP of sunanda or equivalents per manufacturers specification after cleaning the existing surface from dust/ loose particles by applying air by air blowers under pressure etc. Complete as directed. 13 Plastering with C.M. (1:5) 15mm thick in two coats mixed with approved waterproofing compound in appropriate ratio for external surfaces (Backing coat of 10mm & finishing coat of 5mm) including Patches, bays, bands, fluting, scaffolding and fixing of chicken mesh wereever instructed and cleaning of all dirts, raking out joints, hacking, scrubbing, chamfers, beading, curing, all lifts etc. All labour & material complete 14 Plastering with C.M. (1:3) 15mm thick in two coats to internal surfaces (Backing coat of 10mm & finishing coat of 5mm) to walls including paches, bands ,fluting, scaffolding, racking out joints, including fixing of chicken mesh,hacking, scrubbing and cleaning of all dirt, chamfers, beading ,curing all lifts etc.. All labour & material etc. complete 15 Providing and applying polymer modified cementitious waterproofing coating to the surface with acrylic polymer -polyalk wp of sunanda, Pidicrete URP of Dr fixit Or Tapecrete of CICO or any other approved brand ..etc mixed in cement slurry in ratio of 1:2 or as pecified by the manufacturer in three coats as per the manufacturers specifications with all labour, scaffolding. etc complete. 16 White washing in two coat over old work/maintenance painting including scaffolding, thoroughly brooming the surfaces to remove all dirt, dust, loose scales of lime wash etc. All labour & material complete. 17 Painting old (previously painted) iron/metal surfaces with two coat of synthetic enamel paint over a coat of primer of approved make and colour/shade including scrapping, Cleaning and preparing the surface necessary scaffolding/ladder etc. All labour and material complete. 18 Painting old (previously painted) wood/wood based surfaces with two coat of synthetic enamel paint of approved make and colour/shade incl.Cleaning and preparing the surface necessary scaffolding/ladder etc. All labour and material complete. 19 Painting old (previously painted) masonry/concrete/plaster/A.C. sheet surfaces with two coat of ready mixed paint incl. Cleaning and preparing the surface. All labour and material complete. 20 Primer painting old previously painted / plastered wall surface with one coat including preparing the surface by scrapping, removing the old paint and cleaning, required scaffolding etc. All L & M, T & P, etc complete. 21 Distempering with oil bound washable distemper ISI marked of approved brand and manufacture in two coats an old surface including scaffolding, removing the old paint, cleaning and preparing the surfaces, scaffoldings etc. All labour, materials, tools and plant etc. 22 Providing & fixing mirror of size 45 x 35 cm with plywood / PVC base 6mm etc. All tools, plant, labour & material etc complete. 23 Fabrication of sunshade / chajja by supplying & erecting in position structural steel work in single section (light sections up to 34 kg./m) incl. Cutting, hoisting, fixing in position and cleaning the surface, painting two coats of approved quality synthetic enamel paint of approved colour/ shade over a coat of red oxide zinc chromite primer etc. All labour & materials tools & plant etc. complete. 24 Supply of Tree prunning / chain saw machine- 22 inch petrol operated inluding fuel and oil etc and 01 operator and 01 helper for 8 hours a day including replacement of worn out chain (used for cutting trees) on call basis etc. including cutting of logs in 1mtr size and stacking neatly in place as directed. All labour and material etc complete 25 Providing chajja / sunshade by supplying & fixing galvalume sheets of 0.45mm thick of Tata/Jindal or any other equivalent in roofing including drilling holes necessary self drilling screws G.I and bitumen washer etc. All tools,plants,labour and material etc complete. 26 Repairs to the aluminium frame sliding window, aluminium frame door including removing and refixing the shutters, cleaning the grooves, channels, replacing the worn out runners, rubber beeding but excluding the cost of Glass. All tool, plants, labour, material, etc. complete 27 Providing & fixing in position anodised aluminium sliding windows of approved manufacturer to suit two track sliding, using best quality standard extruded anodised aluminium sections (manufactured to relevant I.S. specification) without horizontal glazing bars, glazed with 5.5.mm thick sheet glass fixing to RCC column/masonry with lugs of 16mm x 3.15mm x 10cm long or any other approved size embedded in C.C. (1:3:6) blocks of appropriate size incl. necessary bolting devices, handles, locking arrangements, fixing clips, metal putty, PVC/Rubber beading etc. 28 Providing and fixing windows single shutter panelled/glazed /panelled and glazed without ventilator, without frame but providing sal wood shutter with glass, handles, hooks, latches etc works. All labour & material etc complete. 29 Providing & fixing ornamental grills of approved pattern using M.S. flat, square bars, etc. or any other sections including welding, grinding, cutting, drilling holes, fixing with counter sunk screws etc. All labour & material etc. complete. 30 Supply of General waterproofing compound Dr.fixit pidiproof LW+ 31 Supply of Waterproofing and repair compound Dr.fixit Pidicrete URP 32 Execution of day to day works by supply of high skilled artisans like Carpenters, masons for works of restorative repairs, aluminium doors and window repairs, shutters and gate repairs etc as directed, with tools for a period of 8 hours per day as and when required etc complete 33 Execution of day to day works by supply of mazdoor with tools for a period of 8 hours per day as and when required etc complete 34 Dismantling doors, windows and ventilators having area less than 3.0m2 including removal of frames, fastening etc. from masonry and handing over to Chief Engineers Representative by shifting & stacking at Maintenance Section office Yard at Headland as directed including all tools & plant labour & material complete. 35 Supplying and fixing flush doors without ventilator 35mm thick both sides commercial faced using salwood frame including SS hinges 100 x 58 x 1.8mm size 4 nos. for door shutter providing M.S. hold fast 6 nos. embedded in C.C. (1:3:6) block, 16mm dia M.S. bottom pins etc. Including dismantling of old existing door frame and taking away the same etc finishing the damaged surface with CM (1:3), Painting of door and fame with two coats of synthetic enamel paint over one coat of wood primer. All labour & materials etc. complete. 36 P/F in position anodised aluminium louvered ventilators in single vertical bays with 4.00 mm thick 100 mm wide frosted glass louvers of approved quality / make using best quality standard extra lead anodised aluminium sections comprising to IS-733, frame shall have groove to receiveweather strip all around, glass louvers shall have PVC gap closing gasket on top edge of louvers and approved through lever handle and operation fixed to outer frame and aluminium handle locking device,fixing to masonry, R.C.C. columns etc. as specified by manufacturer all gaps should be sealed with approved sealant etc.including finishing and making good the surface with plaster 1:3, cement concrete mortar, touch up painting for removed old ventilators surface, removing of old ventilators etc. All tools, plant labour & material etc. complete. 37 Supplying and fixing Flush door shutters of marine solid core 30mm thick both sides teak faced including providing 4 nos. S.S. hinges (100x70x4) mm minimum size teakwood beading patties, brass screws, polishing etc.complete. All tools, plant, labour & material etc. complete. (Old fittings like mortice lock,safety chins, etc.to be refitted to the new door. All tools , plant labour & material etc. complete. 38 Supplying and fixing PVC single shutter door of standard size including aluminium frame all the accessories fixing to the wall with expandable fasteners, such SS butt hinges of size 100 x 70x4.0 mm, mimimunm 3 nos. per shutter, Including dismantling of old existing door frame and taking away the same etc finishing the damaged surface with CM (1:3), fixed by C.P. brass counter sunk as approved and fixed to the door frame as specified by the manufacturer or as directed complete.All tools, plant labour & material etc. complete. 39 Providing and fixing Silicone Sealant to the Aluminium window gaps, and gaps of the aluminium frame and walls by using silicone guns for providing sealant . All labour and material etc complete. 40 Providing & fixing wash basin of vitreous china 550x 400mm with all accessories such as C.I. brackets, C.P. brass pillar tap, 32mm size rubber plug with C.P. brass china for outlet, 32mm C.P. brass P trap with 8 cm deep seal with wall flanges, 12mm PVC plastic strap pipe with necessary inlet & outlet connection, 12mm dia brass stop cock including breaking & making good the wall painting brackets etc including dismantling the existing damaged wash basin with accessories including taking away the same etc. All tools, plant, labour & material etc complete. 41 Providing & fixing to the wall / floor etc C.P.V.C. pipes 12/15mm dia including jointing with sockets, bends, tees, etc all cutting , threading, jointing, material cost of pipes & specials, breaking the wall floor making good the same etc including dismantling the existing pipes and taking away the same etc. All tools, plant, labour & material etc complete. 42 Providing & fixing to the wall / floor etc P.V.C. pipes 32mm dia including jointing with sockets, bends, tees, etc all cutting , threading, jointing, material cost of pipes & specials, breaking the wall floor making good the same etc including dismantling the existing pipes and taking away the same etc. All tools, plant, labour & material etc complete. 43 Supplying & fixing in position approved make / type CP brass shower rose 100mm dia including dismantling existing shower rose and handing over the same to the department etc . All tools, plant, labour & material etc complete. 44 Supplying & fixing in position approved make / type CP brass bib cock 12/15mm dia including dismantling existing bib cockand handing over the same to the department etc . All tools, plant, labour & material etc complete. 45 Supplying & fixing in position approved make / type CP brass stop cock 12/15mm dia including dismantling existing stop cockand handing over the same to the department etc . All tools, plant, labour & material etc complete. 46 Providing and fixing Indian type W.C. pan 580mm including dismantling old damaged WC, waterproofing, concrete filling, and redoing the waterproofing in the sunk portion of toilet and refilling with required concrete (1:3:6), joining WC to soil pipes and making joints water tight, P trap, PVC flushing cistern 10 lts, etc with all accessories including jointing with expoy putty etc. All tools, plant, labour and material etc complete.
Contract Date: Aug 20, 2025 Contract Value : 26.07 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : 16.66 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
44.
Defence #7441215 AOC
Tender For Additional / Alternator To Married Quarters At Af Stn Jamnagar; 2 Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.5 Sqm each, complete all as specified and directed. 3 Taking down chowkhat or frame with shutter(without taking off shutter from the frame) area exc 1.5 Sqm but n.exc 4 Sqm each, complete all as specified and directed. 4 Taking down shutters of any description exc 1 Sqm but n.exc. 2 Sqm each complete complete all as specified and directed. 5 Dismantling of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to outside MOD land complete all as specified and directed. 6 Demolition of cement concrete in ground floor and pavings not exc 15 cm thickness below or above ground level, including removal of debries to outside MOD land complete all as specified and directed. 7 Demolition of brick / stone / PCC block masonry built in cement mortar including all quoins, pillars, arches etc. including removal of debries out side MD land, complete all as specified and directed. 8 Demolition of reinforced cement concrete of any description and in any position and( reinforcement not cut in chajja/finsto facilitate demolition) including removal of debries to outside MOD land complete all as specified and directed. 9 Demolition and breaking up drain pipes 100 mm dia (SGSW, AC or RCC hume pipe Class NP2 laid in trenches and jointed in cement mortarcomplete all as specified and directed. 10 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. and brushing neat cement slurry with 3.0 kg of cement per sq metre complete all as specified and directed. 11 M&L 20-25mm thick machine cut kota stone slab flooring, treads etc over and including laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 12 M & L for RCC 1:1.5:3 (Nominal mix) type A1 using 20mm graded aggregates as in Chajjas,andthe like complete all as specified anddirected. 13 M & L for mild steel TMT CRSbars of 5mm dia and over upto and including 10mm dia in stirrups, spacers and bindersand binding with and including mild steel wire annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed 14 M & L for mild steel TMT CRS bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified anddirected 15 M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges flat fair finished surfaces of concrete complete all as specified anddirected . 16 M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n.exc 10cm wide complete all as specified anddirected . 17 M&L for 75 mm thick plain cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate as in plinth protection surfaces finished even and smooth without using extra cement complete all as specified and directed. 18 M& Lfor forming 6 mm wide and 10 mm deep joints in PCC and joints filed with bituminious mastic (1 part of bitumen and 2 part of sand )in plinth protection complete all as specified and directed. 19 M&L for Pre-cast cementconcrete block of 1:3:6 type C1 (20mm graded aggregate)blockmasonry with solid blocks, exc. 10 cm in width and built in cement mortar 1:6 complete all as specified and directed. 20 M&L for Providingprecast cement concrete 1:3:6 type C1 (20mm graded aggregate)solid building blocks or slabs 10cm thick (with plain or interlocking jointsasdirected) setting in mortar, complete, in walls in half brick thickwalls built in cm 1:4 complete all as specified and directed. 21 S&F GI Pressed steel powder coated door frame single rebate 105 x 60x 1.6mm with ball bearing,03 x Nos S/S304 Hinges,06 x Nos Holdfast 200mm x 40mm x 2mm welded to frame ,02 x Nos GI angle tie 20x20x1.60mm and hinges screwed with flat iron 30 x 6 x 120mm long mortar guards and filled with PCCcomplete all as specified and directed. 22 S&F GI Pressed steel powder coated door frame double rebate 125 x 60x 1.6mm with ball bearing,03 x Nos S/S304 Hinges,06 x Nos Holdfast 200mm x 40mm x 2mm welded to frame ,02 x Nos GI angle tie 20x20x1.60mm and hinges screwed with flat iron 30 x 6 x 120mm long mortar guards and filled with PCCcomplete all as specified and directed. 23 S&F Factory made solid UPVC wardrobe with frame profile size 71mm x 45mm with MS stiffner and rubber gasket shall be fixed to wall as per manufacturing instructions and UPVC solid shutters with 6mm thick high pressure compact laminate sheet fixing horizontal & verticle style size 71mm x 28mm thickand MS pipe frame as stiffener size 39mm x 18mm x 1mmwith rubber gasket and UPVC solidoverlap L profile size 16mm x 08mmincluding all necessary stainless steel hardware fittings (Handles, Self closing hinges, lock, Magnetic catcher )complete all as specified and directed as per Drg No CEAG/AR/TD/09R sheet of 01/03 to 03/03. 24 S&F Factory made solid UPVC Kitchen cabinet carecase is made of 35mm thick sandwich panel using UPVC profile 35mmx25mm thick incl shelves and 3mm thick high pressure complete laminate (Phenol formaldehyde bonded) sheet on both sides and EPS insulation in between as well as MS pipe frame as stiffener. Front to cabinetshutter is made of UPVC profile 45mmx20mm and 3mm thick high pressure compact laminate (phenol formaldehyde bonded) sheet incl all necessary stainless steel hardware fittings (handles, self closing hinges & magnetic catcher) complete all as specified and directed as per Drg No CEAG/AR/TD/11R sheet of 01/04 to 04/04. 25 S&F Factory made solid UPVC Kitchen cabinet below cocking platform is made with UPVC solid frame of size 45mm x 20mm shall be fixed to wall as per manufacturing instructions and UPVC solid shutters with 6mm thick high pressure compact laminate sheet fixing horizontal & verticle style size 45mm x 20mm thick including all necessary fittings (Handles, Self closing hinges, Magnetic catcher )complete all as specified and directed as perDrg No CEAG/AR/TD/11R sheet of 01/04 to 04/04. 26 S&F Factory made solid UPVC Kitchen shelves made of 35mm thick with profile 35mmx17mm thick and 03mm thick highpressure compact laminate sheet on both sides and EPS insulation in between as well as MS pipe frame as stiffener including all necessary fittings complete all specified and and Drg No CEAG/AR/TD/11R sheet of 01/04 to 04/04. 27 M&L for factory made flush shutters,35mm thicksolid core construction, with block board core and plywood face panels, commercial type on both sides with 12mm thick teak wood lipping/beading all around including0.90mm thick decorative laminate type 1 on both sides,of surface finish, colour as approved, fixed with approved adhesive as per manufacturers instructions complete all as per specified and directed by Engineer-in-Charge. 28 S&F 35 mm thick factory made second class hardwoodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass / gauge, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkhats complete. complete all as specified and directed. 29 S&F Stainless steel wire cloth. 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples to wooden shutters complete all as specified and directed. 30 Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm havingsingle rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fireresistant grade unsaturated polyester resin and choppedmat. Door frame laminate shall be 2mm thick and shallbe filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady theframe., complete as specified and directed. 31 Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand andmanufacture, made with fire - retardant gradeunsaturated polyester resin, moulded to 3 mm thickFRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned woodinside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate forpanels conforming to IS: 14856, including fixing toframes, complete as specified by the manufacturerand as per directions of Engineer- in-charge. 32 S&F SS 304 grade hinge 25x25x100mm long 3mm thick with ball bearingfixed to chowkhat complete all as specified and directed. 33 S&F 200 mm long aluminium anodised barrel tower bolt of extruded sectiion complete all as specified and directed. 34 S&F 150 mm long aluminium anodised barrel tower bolt of extruded sectiion complete all as specified and directed. 35 S&F 150 mm long aluminium handle, fabricatedtype, anodised complete all as specified and directed. 36 S&F 100 mm long aluminium handle, fabricatedtype, anodised complete all as specified and directed. 37 S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. 38 S&F 300 mm, size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed. 39 S&F 140 mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. 40 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete all as specified and directed. 41 S&F powder coated aluminium(minimum thickness of poweder coating 50 micron) for shutters of doors,windows & and ventilators including providing and fixing hinges/pivotes/handle and making provision for fixing of fitting whereever required including the cost of EPDM rubber/neoprene gasket required(fitting shall be paid separately) with extruded built up standered tubular sectios/ appropriate Z section and other sections of approved make conferming to IS 733 and IS : 1285 , fixing with dash fasteners of required dia and size including necessary filling up the gaps at juctions , ie at top , bottom and sides with required EPDMrubber neoprene gasket,concealed type lock for all three shutter, PVC roller etc . Aluminium sectios shall be smooth , rust free , straight , mitred and jointed mechanically wherever required including cleat angle, luminium slap beading for glazing/ panelling , C.P. brass stainless steel screws complete all as specified and directed.Note for item No 36 & 37 : (i)Three track aluminium windows : (a) Frame (top & side) section shall be of size 92.00 x 31.75 x 1.50mm (Section No 20831)(b) Frame (bottom) section shall be of size 92.00 x 31.75 x 1.50mm (Section No 20832) (c) Top & Side Members of shutter Section shall be of size 18.00 x 40.00 x 1.55mm (Section No 20738) (d) Shutter Interlock section shall be of size 18.00 x 40.00 x 1.45mm (Section No 20737) (e) Bottom Members of shuttersection shall be of size 18.00 x 40.00 x 1.55mm (Section No 20736). (ii) Ventilators : (a) Frame top,bottom & sides shall be of size 100x50x1.50mm (Section No S4859) (b) Frame for wire mesh shall be of size 50x25x1.00mm (section No 14039).Section No given above are of Make Jindal 42 S&F 5mm figured glass , pin headed type and glazing with oil putty in square n.exc 0.50 m in each pane for windowes/ventlators complete all as specified and directed. 43 M&L for preparation of new wooden surfaces, exc 10 cm width or girthand applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. 44 S&F GI powder coatedframed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spiked framed guard bars barred iron doors ladders framed blasters walkways railingsframework of water tanks and similar workcomplete all as specified and directed. 45 S&F in repair Stainless steel curtain rods of 25mm dia complete all as specified and directed. 46 S&F SS ornamental stainless steel holding brackets /end cap for 25 mm dia curtain rods complete all as specified and directed. 47 S&F Stainless steel peg set of 5 hooks including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms). 48 Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removal of debries to outside MOD land complete all as specified and directed. 49 M &L for plain cement concrete type E-2 (1:5:10), using 40 mm graded stone aggregate, for filling sunken portion of toilet and similar work complete all as specified and directed. 50 M&L for providing water proofing treatment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make as approval in Technical Instruction 5/2003 by adding: (a) 15mm thick rendering CM (1:4) with Liquid water proofing compound 200ml per 50kg bag of cement on floor and wall , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowedto dry. (Note: Water proofing compound shall be measured and paid separately). (b) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hrs.(c) Second layer of slurryof cement @ 0.242 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs including complete removal of old treatment to sunken portion etc complete all as specified and directed. 51 M&L for Non skid,(Joint Free)coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) polished area of each tile exceeding 0.11 sqm but not exeeding 0.18 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. 52 M&L for Non skid,(Joint Free)coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) polished area of each tile exceeding 0.11 sqm but not exeeding 0.18 sqm as in vertical surface skirting/Dado of walls etc laid overrendering 10 mm thickcement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. 53 M&L for Non skid, (Joint Free) coloured ceremic tiles 7 to 8 mm thick (Square / rectanguler) polished area of each tile exceeding 0.18 sqm but not exeeding 0.38 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. 54 M&L forcoloured glazed ceramic(Joint Free)tiles of size 450X 300X 7 mm to 8 mm thick (square / rectangular) thick as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. 55 M&Lfor green Marble work 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like set over & incl 15mm thick cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed. (Note :-(a) Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations as directed. 56 M&L for18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in set over & incl 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. (Note :-(a) Rounding to edges of stone slabs one edge, such as in window jamb and cills, steps, cooking platform, and other similar situations as directed. 57 M&L 20-25mm thick pre polished machine cut kota stone slab flooring, treads etc over and including 15 mm thick screed bed in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note :-(a) Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations as directed. (b) Forming grooves for treads, straight or winding as directed 58 M&L 20-25mm thick pre polished machine cut kota stone slab in riser of steps, skirting,dado and pillar laid over and including 10 mm thick plaster in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.Note :-(a) Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations as directed. (b) Forming grooves for treads, straight or winding as directed 59 Rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and directed. 60 S&F in repairs 15mmbore bib taps ,fancy type of cast copper alloy chromium plated withcapstan handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 61 S&F in repair 15mm sizebib tap cast copper alloy chromium plated, with capstan head , screwed down , screwed for iron pipe complete complete all as specified and directed. 62 S&F in repair 15mm bore dia stop valve/angle valve cast copper alloy chromium plated, fancy type screwed down high pressure with capstan handle, screwed both ends for iron pipe or for union complete all as specified and directed. 63 S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position completeall as specified. 64 S&F Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. 65 S&F in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed 66 S&F 15mmcold and hot wall mixer brass chromium plated with bend pipe including all accessories completeas directed by Engineer-in-Charge. 67 S & F in repair 10 Ltr capacity PVC valveless , syphonic action type , flushing cistern low level white with inlet ball valve float and handle including bracket , 32 mm dia pvc flushing pipe complete all as specified and directed. 68 S& F in repairs brass chromium plated overhead shower 125 mm size with 225 mm arm and flange for 15mm inlet pipe complete complete all as specified and directed. 69 S&Fin repair white vitreous china wash hand basin of size550 x 400 mm, fixed over & including GI brackets comprising of the following items :-(a) Waste fitting 32 mm dia chromium plated with long screwed shanks and fly nut, flange end, bedded in red lead cement and other end fixed complete.(b) 15 mm size Pillar tap cast copper alloy with capstan head, chromium plated screwed down high pressure with or withoutlettered hot or cold with long screwed shank and fly nut screwed for iron pipe complete all as specified and directed.(c) 32 mm dia Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed. 70 S&F 32mm bore dia light grade GI pipe cocealed in wall or laid in floors complete all as specified. 71 S&F stainless steel kitchen plate rack of size 750mmx600 mmx250mm deep, fabricated with 0.63 mm sheet fixed in position on wall complete all as specified and directed. 72 S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscomplete all as specified and directed 73 S&F sheet glass shelf assembly consisting of 5.5mm thick sheel galss shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. 74 S&F stainless steel soap dish of size160x160x1mm thickfixed to plugs with chromium plated brass screws as complete all as specified and directed. 75 S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, with plastic water closet seat, white, closed pattern with flat bottom, and cover with aluminised hinging device, including all connections complete complete all as specified and directed. 76 S&F in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580mm x 440 mm white with integral foot rests icluding 100 mm dia CI P’ trap or S trap including all connection and provision of lime concrete base complete all as specified and as directed. 77 S&F in repairs brass Chromium platedtubular Towel rail 20 mm dia D type 600mm long bettwen flangefixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. 78 S & F Stainess steel Towel Ring fixed with and including Chromium plated brass screws complete all as specified and directed 79 S&F in repairs stainless steel sink, 1.00 mm thick for kitchen, with plug, washers and wastes coupling, including bedding in cement mortar on to draft wall or including fixing cantilever brackets, connecting union to pipe etc, overall size 495 mm x 420 mm, with bowl size 410 mm x 330 mm x 160 mm, complete complete all as specified and directed. 80 S&F in repair PVC connection 15mm dia and 45 cm long with 2 Nos PTMT nuts,complete all as specified and directed by Engineer in Charge. 81 S&F 100mm cast iron sanitaryconnections—short connections pipeof length upto 300 mmcomplete all as specified and as directed. 82 Taking down CI/rain water pipes/PVC pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks, complete all as specified and as directed 83 S & F 75mm dia UPVC (SWR) pipes,Type B, single socketed, in any length with rubber ring joints, fixed in walls/ factory made pipe supporting system as per manufacturer instruction and as directed. Note : Pipe shall be fixed on wall at an over multi pipe bracket system stack clamp at an alternalte interval of 1m(U bolt with noise absorbing transparent ribbed silicon ribber sleeve of 2mm thickness with set of knurling flange nuts+bracket+ support) confirment with outer dia of pipe fixed at intervals of every meter at a specified distance from the wall for vertical and horizontal lines, which are made of deep draw low carbon hot rolled gauge corrected (HRGC) steel (Material grade IS 1079DD), hot dip galvanising (IS 2629)+ ZNAL (Zinc Aluminium flake) coated with ribbed support and all as per drg No CEAG/AR/TD/08R 84 S & F 75mm dia UPVC (SWR) pipes,Type B, single socketed, in any length with rubber ring joints, laid in trenches or in floor completeall as specified and as directed. 85 S & F UPVC SWR 75mm dia bends of any radius complete all as specified and directed 86 S & F UPVC SWR 75mm dia branch piece, single (Single Y) equal or unequal complete all as specified and directed 87 S & F UPVC SWR 75mm dia branch piece, Double(double Y) equal or unequal complete all as specified and directed 88 S & F 110mm dia UPVC (SWR) pipes,Type B, single socketed, in any length with rubber ring joints, fixed in walls/ factory made pipe supporting system as per manufacturer instruction and as directed. Note : Pipe shall be fixed on wall at an over multi pipe bracket system stack clamp at an alternalte interval of 1m(U bolt with noise absorbing transparent ribbed silicon ribber sleeve of 2mm thickness with set of knurling flange nuts+bracket+ support) confirment with outer dia of pipe fixed at intervals of every meter at a specified distance from the wall for vertical and horizontal lines, which are made of deep draw low carbon hot rolled gauge corrected (HRGC) steel (Material grade IS 1079DD), hot dip galvanising (IS 2629)+ ZNAL (Zinc Aluminium flake) coated with ribbed support and all as per drg No CEAG/AR/TD/08R 89 S & F 110mm dia UPVC (SWR) pipes,Type B, single socketed, in any length with rubber ring joints, laid in trenches or in floor completeall as specified and as directed. 90 S & F UPVC SWR 110mm dia bends of any radius complete all as specified and directed 91 S & F UPVC SWR 110mm dia junction single (Single Y) equal or unequal complete all as specified and directed 92 S & F UPVC SWR 75mm dia branch piece, Single(Single Y) equal or unequal complete all as specified and directed 93 S&F UPVC (SWR) vent cowl 75 mm dia complete all as specified and directed 94 S&F UPVC (SWR) vent cowl 110 mm dia complete all as specified and directed 95 S & F 75mm UPVC nahani trap, plain with grating including jointing with solvent cement complete all as specified and directed. 96 S & F 75mm UPVC gullytrap, plain with grating including jointing with solvent cement complete all as specified and directed. 97 S&F in repair Stainless Steel 304 Gratings in square type and ofsize 125mm x 125mm made in two parts for smell and mosquito proofing with double jalicomplete all specified and directed 98 S&F40mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors complete all as specified & directed. 99 Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc,including removal of debries out side MoD land complete all as specified and directed. 100 M&L for rendering 15 mm thickin two layers Istlayer 10 mm thick and 2nd layer 5 mm thick,final coat shall be mixed with WPC on brick/stone/ PCC block masonry wall surface in cement mortar 1:4, finished even and smooth withoutusing extra cementcomplete all as specified and directed. Note : Water proofing compound shall be measured and paid for separetly 101 M&L for rendering 15 mm thick on other than fair faces of brick/stone/ PCC block masonry wall surface in cement mortar 1:4, finished even and smooth withoutusing extra cementcomplete all as specified and directed. Note : Water proofing compound shall be measured and paid for separetly 102 M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces or stone masonry surfaces in cement mortar 1:6, finished even and smooth withoutusing extra cement complete all as specified and directed. 103 M&L for 5mm thick rendering in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement complete all as specified and directed. 104 M&L for preparation ofnew plastered surfaces of walls & applying two coat of Distemper oil emulsion overa coat of primer on wall surfaces applied by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed. 105 M&L for complete removal of existing treatment from wall including brooming down or steel wire brushing, scraping down complete including preparation of old surfaces and applying two coat of Oil bound Distemper over a coat of primer on wall surfaces applied by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed. 106 M&L for preparation of new plastered surface of wall andapplying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces two coats of Acrylic emulsion (exterior weather coat) paint of any tint as approved over one coat of primer applied by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed. 107 M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash applied by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed. 108 M&Lfor preparation of old decorated surfaces of ceiling (plastered or unplastered)by brooming down , scrapping down smoke soot, moss and efflorescent salts and trading oil and greasy spots etcand applying two coat of white wash on ceiling applied by mechanical means using suitable tools and plants as per manufacturers instructionscomplete all as specified and directed. 109 M&L complete removal of existing treatment from external surfaces on walls by wire brushes & stopping of surfaces and levelling/edging the disturbedplaces/edges using necessary filling compound of Allek Putty to obtain smooth regular/even finish using sand paper and applying two coats of exterior acrylic emulsion (weather proof treatment) over one coat of primer applied by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and as directed ( The tint and shade be as approved by the GE) Note:- The treatment shall be carried out by the authorised applicator of the firm. 110 Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-charge. 111 M&L for repairing the edge/corner of chajja/roof projection and similar work by removing of plastered width/girth exceeding 15cm & n.exc 30cm and making good with 15mm rendering in cement mortar 1:3 to match, including chicken wiremesh netting on exisiting surfaces including necessary form work complete all as specified.(Note- Height of building upto 15mtr) 112 M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. 113 M&L for plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate,in roof for paddingto achieve therequired slopecomplete all as specified and directed. 114 M&L for 10mm thick rendering on concrete surface in CM 1:3 to be finished even and smooth with out using extra cement mixed with water proofing compound as per manufacturer instructions complete all as specified and directed.Note:-WPC will be measured & paid separately. 115 Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg/Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane with non-woven polyester reinforcement/mat (center core), weight not less than 3.50 Kg/Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete complete all as specified and directed.Note : (a) Work shall be carried out upto 2 & 3 storey bldg, contractor to quote rates accordingly.(b) The membrane shall be taken upto height of minimum 300mm through a concrete fillet 75mmx75mm and shall be inserted inside agroove cut in the parapet and fixed. If the height of parapet is 300 mm or less, membrane shall be taken till top of the parapet and finished after covering the top surface of the parapet. For RCC inverted beam, the whole beam shall be covered with membrane irrespective of the depth. In case of roof projection the membrane shall be taken upto the roof edge and sealed by torch application. 116 Supply and provisioning high performance, general purpose, non shrink, cementious repair micro concrete as per manufacturers instructions to an average thickness of 40 to 70 mm for beam and column, fluid micro concrete shall be mixed with 6 mm down coarse stone aggregate and specified quantity of water and fixed using a power including the cost of all materials, rent of tools, scaffolding and labour charges complete all as specified and directed. 117 M&L chipping / dismantling of loose damaged concrete removed carefully by using mechanical concrete upto good parent concrete to expose the existing reinforcement (direct hammering should be avoided) average thickness of chipping average 40 -70 mm alround lintel / beams / column upto 10 mtr height including scffolding complete all as specified and directed 118 Supplying and application of rust remover/converter over the corroded reinforcement bar where ever/Polymer modified mortar micro concreting is required and cleaning the same after application incl cost of all materials, rent of tools, scaffolding, cost of brushes etc. upto 10 mtr heightcomplete all as specified and directed. 119 M & L for grouting of all RCC structure as per manufcature instructions with low viscosity epoxy resin system compising of resin and hardner by using specialized injection instrument injected through nipples including drilling necessary holes of required sizeat distance of approx. between 150mm to 300mm and fixing of PVC Nozzles by quick setting ready made epoxy based plugging putty, scaffolding and pressure of injection may vary from 4 kg/cm2 to 7 kg/cm2 to RCC beams/chajjas/slabs/columns at all heights all as per manufactureres instruction and as directedupto 10 mtr height.NOTES:(i) Payment shall be made as per the weight of epoxy formulation as calculated based on net contained weight of epoxy actually consumed in the work.(ii)The sealed container shall first to be brought to the site and handed over to MES store and thereafter to be used as and when required in the presence of MES executive.(iii)Record of day to day consumption with location and date etc shall be maintained in the serially numbered certified bounded register with shall be signed by contractor and Enggr-in-Charge.(iv) The quoted rate is deemed to include the cost for sealing of cracks required for grouting purpose. 120 Supplying and application of epoxy resinconcrete bonding agent as per manufacturers instructions over the old concrete surfaces including the cost of all materials, rent of tools, scaffolding, cost of paint, brush etc. upto 10 mtr height complete all as specified and directed. 121 M/L for rendering 20 mm thick polymer modified mortarover face of Concrete of column/Beams etc. for height upto 10 mtr in CM mortar 1: 3 along with adding modified styrene butadiene rubber emulsion as per manfactueres instruction and finishing even and smooth. (Modified styrene butadiene rubber emulsion will be measured and Paid seperately) ( Cost of scafflding upto 10 mtr height shall be deemed to be included in the quoted rates) complete all as specified and directed. 122 M&L for providing and injecting chemical emulsion for Post constructional antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed. 123 M&L Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors. 124 S&F 5.5mm thick tinted sheet glass , ordinary quality and glazing with oil putty in square n. exc 0.50 m in each pane for windowes/ventlators complete all as specified and directed. 125 Supply only modified styrene butadiene rubber emulsion complete all as specified and directed. 126 Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces complete all as specified and directed. 127 Demolition /dismantling of old APP membrane in roof treatment and rubish off premises complete all as specified and directed. . 128 Writing letters or figures (block Roman, Italic or Indian) nexc 30cm high shall be painted thick paint, so that they stand out boldly and solidly without showing signs of brush marks, if necessary, they shall be repainted until the desired result is obtained complete all as specified and directed 129 Writing letters Stops, commas, short lines, dashes, hyphens, brackets, etc shall be painted with thick paint, so that they stand out boldly and solidly without showing signs of brush marks, if necessary, they shall be repainted until the desired result is obtained complete all as specified and directed 130 S&F corner glass selfof size 200mm crafted from high quality glass including brass bracket etc. complete all as specified and directed. 131 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete 132 Material & Labour forstainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel brackets,nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. 133 Dismantling of Stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc complete 134 S&F PVC cabinet mirror of size 125mmx450mmx550mmcomplete all as specified. 135 M & L for 100 mm thick cement concrete1:3:6type C2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed. 136 M&L forProviding and laying 60mm thick factorymade chamfered edge cement concrete paverblock of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method usingPU uld, laid in required colour & patternover and including 50mm thick compactedbed of fine sand,mpacting and properembedding/ laying of inter locking paverblocks into the sand bedding layer hrough vibratory compaction by using platevibrator, filling the joints with sand andcutting of paver blocks as per required sizeand pattern, finishing and sweeping extrasand; complete all as specified and directed. 137 M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including all nacessary excavation and earth work in any type of soil and making drainage opening whereverrequired complete all as specified and directed. 138 M&L for PCC (1:3:6) type C2 ,40mm graded aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid & tested for 150 mm bore for SGWG pipescomplete all as directed by EIC. 139 Material and labour for reinforcement cement concrete pipes, 150mm bore, class NP2, laid and jointed complete with collars all as specified and as directed. 140 M&L PCC (1:2:4) type B1 using 20 mm graded aggregate for coping and as in benching inside the man holes including necessary formworkcomplete all as specified anddirected. 141 M&L for precast cement cocrete cover slabs (1:2:4) type B1 (20mm graded agg) set in CM 1:4complete all as specified anddirected. 142 M&L for PCC (1:3:6) Type C2 using 40 mm graded stone aggregate as in foundation, filling and mass concretecomplete all as specified and directed. 143 M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped endscomplete all as directed by EIC. 144 M&L PCC (1:2:4) type B0 using 12.5 mm graded aggregate for copingincluding necessary formworkcomplete all as specified anddirected. 145 Material and labour for reinforcement cement concrete pipes, 450mm bore, class NP2, laid and jointed complete with collars all as specified and as directed. 146 Excavation in trenches, nexc 1.5m wide and nexc 1.5m deep and getting out in hard/dense soil complete all as specified and directed 147 Returningfilling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick soft & loose soil complete all as specified and directed 148 Removing excavated material (exc1.50Km and n exc 5.00Km) outside defence land and depositingat a level n exc 1.5 m above the starting pointcomplete all as specified anddirected. 149 HOT WATER SUPPLY , INTERNAL & ENTERNAL WATER SUPPLY WORKS (B/R & E/M) 150 Taking up or down 15 mm bore steel tubing and connections, complete all as specified and as directed 151 Taking up or down 20 mm bore steel tubing and connections, complete all as specified and as directed 152 Taking up or down 25 mm bore steel tubing and connections, complete all as specified and as directed 153 Taking up or down 40 mm bore steel tubing and connections, complete all as specified and as directed 154 M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete. 155 Supply and fixing 15mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe linecomplete all as specified and directed. 156 Supply and fixing 20 mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe linecomplete all as specified and directed. 157 Supply and fixing 25 mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe linecomplete all as specified and directed. 158 Supply and fixing 40 mm bore galvanised steel water tubing, medium grade including necessary fittingssuch as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe linecomplete all as specified and directed. 159 S&F CPVC 20 mm pipe for water heater outgoing , ISI Marked conforming to IS 1239 Part-I 2004, 20 mm bore with and including all fittings such as bends , elbows, tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed. 160 Supply and fixing of 20mm dia Gun Metal globe / Gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 161 Supply and fixing of 25mm dia Gun Metal globe / Gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 162 Supply and fixing of 40mm dia Gun Metal globe / Gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 163 Dismantling water tanksof capacity exc 250 and not exc 500 litres removal to store complete all as specified and directed. 164 Supply and fix 500 litres capacity triple layer (white), rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc. complete all as specified and directed. 165 S&F ballvalves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule and fixed 20mm dia complete all as specified and directed. 166 Supply only solar glass tube suitable for glass tube collector of 58mm dia and 1800mm long complete all as specified and directed 167 Supply only solar glass tube suitable for glass tube collector of 48mm dia and 1800mm long complete all as specified and directed 168 Supply and Fixed in Repairs Hot water tank suitable for 100LPD tube collector complete all as specified and directed 169 Taking downand refixing of cold water tank installed for solar water heating system,dismantaling of incoming and outgoing pipe connection ,removal of outgoing pipe line any size and type from cold water tank to solar heating system ,dismantaling of gate valves in outgoing pipe and Refix itto another desired location complete all as specified anddirected. 170 Taking downand removal of hot water tank , solar water heating system ETC type,dismantaling of incoming and outgoing pipe connection ,dismantling of pipe line any sizeand type from solar heating system to hot water tank and hot water tank to gate valve,dismantling of gate valves in outgoing/incoming,certain other accessories connected to solar water heating systemcomplete all as specified and as directed. 171 Taking down and Refixing of steel structure associated with solar water heating systemcomplete all as specified and as directed. 172 M & L for reassembling of solar water heating sysyem ETC type any capacity complete with cold water tank,hot water tank,steel structure ,outgoing pipe from cold waterto solarsystem,pipe line from solar sysytem to hot water tank along gate valve,NRV and other accessories,pipe line from hot water tank till gate valve and,certain other accessories connected to solar water heating systemcomplete all as specified and as directed. NOTE:-Any material damage during dismantaling shall be replaced and paid under respective items. 173 Supply and fix solarwater heater element 2000 W with thermostat cut off electric water geyser temperature controlling sensorsuitable for 230 V ac complete all as specified and as directed 174 M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete all as specified and directed. 175 M&L for MCB single pole & neutral240 volt C curve 10 KA (32 to63)Amps capacity IP 20complete all as specified and directed. 176 M&L Sub main wiring using PVC insulated and unsheathed multi stranded FRLS copper conductorcable using approved colour code as per IS drawing in and incl PVC casing and capping of suitable size with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete asspecified and as directed of the following sizes of cables.(a) Using two single corePVC insulatedFRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wireNote :2 runs of 4sqmm copper cable & 1 run of 2.5sqmm copper cable and one run of casing & caping shall be measured as one unit 177 HOT WATER SUPPLY 178 Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point includingfixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made asper conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surfaceand finishing the surfaces with distemper/white washing/colour washing as per existingcomplete all as specified and directed. 179 Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc complete all as specified and directed. 180 Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings,bulk head fittings, tube light fittings ,building street light , floodLED lights etc all as specified and directed. 181 M&L for point wiring with 1.5 Sqmm, multi-stranded copper conductor single core, FRLSH, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in surface/concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : -Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. 182 One light / fan point controlled by one switch one way. 183 One 3 pin 5 Amp switch & socket outlet on same board with other switches. 184 One 3 pin 5 Amp switch & socket outlet on Independant board. 185 One bell point controlled by one switch 5 Amps bell push. 186 One light point controlled by two Nos 5 Amps switch two way 187 All same as per item ser No 178 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, FRLSH, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board complete all as specified and directed. 188 All same as per item ser No 178 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, single core, FRLSH,PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers complete all as specified and directed. 189 S&F Ceiling rose surface bakelite 65x50mm three terminal complete all as specified and directed 190 S&F switch modular single pole one way 6 Amps 230 volt 1 module complete all as specified and directed 191 S&F switch modular single pole two way 6 Amps 230 volt 1 module complete all as specified and directed 192 S&F Socket modular 6 Amp 2/3 pin combined two module complete all as specified and directed 193 S&F switch modular single pole one way 16 Amps 230 volt 1 module complete all as specified and directed 194 S&F Socket modular 6&16 Amp 2/3 pin combined two module complete all as specified and directed 195 S&F Bell Push modular single pole one way 6 Amps 230 volt 1 module complete all as specified and directed 196 S & F Single pole and neutral enclosure with a two pin and earth metal plug and socket complete with one single pole MCB of 5 to 30 amp,240 volt B Curve 20KA,IP 20 complete all asspecified and as directed 197 Supply and fix of Bell musical type AC 230 Volts, as directed including connecting complete all asspecified and as directed. 198 S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified and directed. 199 S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 10 watt, channel housing & diffuser of length 600 mm (approx.) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified and directed 200 S & F bulkhead fitting 10watt made die cast aluminium housing with complete assembly and PC opal diffuser suitable for surface/wall mounted dust and water resistant complete all as specified and as directed . 201 Taking down carefully (copper/aluminium ) submain wiring complete of any type (batten/surface conduit or concealed ) for socket point or power point complete with all fittings such as swiches sockets pendants etc complete and making good distuebed surface of wall,floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing/colour washing to match with the existing surface complete all as specified and directed 202 M&L Sub main wiring usingPVC insulated and unsheathed multistranded FRLS copper conductorcable using approved colour code as per IS drawing in and incl 20mm PVC conduit with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete asspecified and directed of following sizes of cables. 203 Using two single corePVC insulatedFRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire complete asspecified and directed Note : 2 runs of 6 sqmm copper cable & 1 run of 6.0sqmm copper cable in and including 32 mm PVC conduit shall be measured as one unit 204 Using two single corePVC insulatedFRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire complete asspecified and directedNote : 2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit 205 M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management,reversible door for for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection , with blanker if any mcb slot remain emptycomplete all as specified and directed. 206 M & L for distribution board (DB), double door type, as per IEC 61439-3 made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 4 way with 150 Amps rated copper busbar, 415 Volts with in built TPN MCB 100 Amps, 10 KA, 01 ,new MCB SPN 32 Amp, 10KA -06Nos, IP 54 protection,,reversible door for IP 43 & IP 54 ,flush mounted to wall complete all as specified and directed. Note : Rates are inclusive for flush(Concealed ) mounted of DB, TPN ,MCB SPN 32Amp and 63Amp / Schnieder (Multi-9). 207 M&L for RCCB for earth leakage protection double pole ,30ma for 240 volt25 amp capacity IP 20complete all as specified and directed 208 M&L for MCB single pole & neutral240 volt C curve 10 KA (upto 32)Amps capacity IP 20complete all as specified and directed 209 M&L for MCB single pole,5 to 30 Amp 240 volt B curve 10 KA, IP 20complete all as specified and directed 210 S&Fbuilding security LED Light fitting 35 watt, system efficiency not less than 100 lumen / watt, IP66 protection,consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws,fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed. 211 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire mm as 4.0mm dia bymeans of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electricalplate no.3 includingearth pit in PCC concrete 1:2:4 type B-1,Cast iron cover 10 MM THICK HINGED to CI frame ,excavation and earth work in any type of soil and including protectionpipe 15mm dia and water pipe GI tubing 20mmlight grade with funnel and wire mesh connected to earthing test point complete all as specified and directed Note:(i)Rates are inclusive of 7.5m long GI earth wire 4.0mm dia (ii)Rates of CI frame,RCC Pit cover,funnel and wire mesh included in the cost of item. 212 S & F Exhaust fan 300 mm sweep, copper wounded, four blade, metal body, BEE approved/ISI marked, air delivery shall not be less than 230 CFM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer, including taking down old unsv Exahaust fans and deposited to store yard of E/M section at AF-IIcomplete all as specified and directed. 213 S & F Exhaust fan 250 mm sweep, copper wounded, four blade, plastic body , BEE approved/ISI marked, air delivery shall not be less than 230 CFM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified and directed.(Note: Rate quoted for above shall be inclusive for making of hole of suitable dia for fixing of exhaust fan in stone masonary bldg/ aluminium window ) 214 M & L for taking down Ceiling fan of any size and its connection & other accessories connected to ceiling fandeposited to store yard of E/M section at AF-II complete all as specified and as directed. 215 S & F Energy efficient BLDC Ceiling Fan, 1200mm sweep BEE 5 star rated, AC single phase, 230 volts, 50 Hz,with remote control regulator and connecting up including provision of three core flexible copper wire of size 1.5 sqmm from ceiling rose to ceiling fan complete in all respectand all accessories complete all as specified and directed. 216 Supply & Fixing 5 star rated electric storage water heater (vertical type) 25 Ltr, 230 V, AC, Single phase power input 2000w, standing loss in kWh 24 (hours) 45°C 0.511 KW h with and including connecting fastners nuts not less than 100 mm with suitable nut, bolt & washers grouted in walls with complete masonary work for proper mounting of Geyser fastning bolts etc as directed as site reqmt and making necessary inlet and outlet water connection brass chromium plated connection pieces with brass hexagonal adopters and washer at both side, suitable for 15 mm dia pipe and 450 mm long.of size 600mm as well aselectric connection including testing on load, including taking down old unsv Gyser and deposited to store yard of E/M section at AF-IIcomplete all as specified and directed. 217 NOTE : Amount of credit of Rs 7,67,711.28 for retrieved material is mentioned in SCHEDULE OF CREDIT on Srl Page No 30 & 31 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Contract Date: Jun 06, 2025 Contract Value : 3.40 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Ref. Documents Contract Value : 93,000
Government Departments No of Bidders 1
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 68,750
Government Departments No of Bidders 2
West Bengal View Result →
49.
Educational and Research Institute #7183083 AOC
E-Tender For Supply, Installation And Commissioning Of Devices, Machineries, Equipment And Tools, Etc. In Laboratories And Workshop Of Civil Engineering, Instrumentation And Control Engineering, Science And Humanities Depart. Of Maynaguri Govt. Poly E-Tender For Supply, Installation And Commissioning Of Devices, Machineries, Equipment And Tools, Etc. In Laboratories And Workshop Of Civil Engineering, Instrumentation And Control Engineering, Science And Humanities Dprt. Of Maynaguri Govt. Poly. , Aggregate Crushing Value Test Apparatus As Per Is:2386 (Part 4) 1963 , Auger Extra Extension Rod, 1 Meter Long With Screw Type Fitting 6 To 12 Ms Auger To Drilling Into Soil Upto 3 M Manually. Mostly Used For Normal Soil And Earthing Pit Purpose. , Blaine Air Permeability Test Apparatus For Measuring Fineness Of Cement As Per Is 5516. Air Permneability Apparatus (Blaine Type) With Isi Certification Mark Is;S516, Fitted In Aluminium Box With Permeability Cell. U Tube Manometer, Mounted On Stand. Perforated Metal Disc. Plunger. Rubber Stopper. Rubber Tube, 20 Cm Long. Filter Paper Discs (Twelve Nos.). Dibutylphthalate Liquid, 100 Ml Bottle. Punch. Non Perforated Disc. Suction Bulb And All Other Accessories Required As Per Is Code. It Should Be Supplied With Standard Cement Required For Calibration(Calibration To Be Done By The Supplier In Presence Of Concerned Authority) And Mercury Of Requisite Quantity, Crucible. , Bod Incubator Chamber Made Of Aluminium 375 Mm X 375 Mm X 450 Mm With 10 Numbers 300 Ml Bod Bottle. Specifications: Temperature Range 5 To 60°C, Temperature Accuracy + / - 0.5°C, Temperature Uniformity + / - 0.5°C, Power 220 Volt, Temperature Control Microprocessor Control, Cabinet M.S. Steel Powder Coated Inner Chamber Stainless Steel, Shelves 3 Stainless Steel, Etc. , Buoyancy Balance Buoyancy Balance Helps In Determining The Specific Gravity And For The Water Absorption Of The Aggregate. It Is Fitted With The 15 Kg Capacity X 0.5 Gm Of The Electronic Balance. Buoyancy Balance Comprising Of An Electronic Balance Of 15 Kg Capacity, Chain & Ratchet Assembly In A Steel Tubular Frame. , Cbr Value Apparatus As Per Is 2720 (Part-16)-1987 Laboratory California Bearing Ratio Test Apparatus, Motorised Laboratory Cbr Apparatus Meets The Essential Requirements Of Is: 2720(Part Xvi) With The Mould As Per Of Is: 9669. , Cod Digester Along With Vials,Holding Rack, 16 Sets Of Glassware (Cod Digestion Tubes With Screw Caps And Cod Air Condensers) Holds 16 Nos. Of 16 Mm X100 Mm Dia Tube. Temperature Range 0- 200 Degree Celcious, Temperature Can Be Set Within This Range. Time Range 0 To 120 Minutes, Stability Plus Minus 0.5 Degree Centigrade, Over Temperature Cut Off. When Digestion Complete, Reactor Automatically Turns Off And Will Sound An Alarm. 230 Volt. 16 Mm X 100 Mm Culture Tubes With Tfe-Lined Screw Caps ( 16 Nos.) Holding Racks Of Stainless Steel. , Compacting Factor Test Apparatus Compaction Factor Apparatus As Per Is: 5515-1983 With Nabl/Nccbm Certificate. , Constant & Falling Headpermeability Apparatus With Water Reservoir As Per Is 2720 (Part 17)-1986. Laboratory Permeability Apparatus: Is: 2720 (Part-17), Is 11209 Suitable For Both Constant Head As Well As Falling Head Permeability Tests. Stand With Three Glass Tubes Of 6 Mm, 10 Mm And 20 Mm Dia Approx. Metallic Mould 100 Mm Dia X 127.3 Mm Height, 1000 Ml Volume. Extension Collar 100 Mm Dia X 60 Mm Height. Drainage Base Plate With A Recess For Porous Stone And An Outlet Valve. Metallic Clamping Ring Drainage Cap With Recess For A Porous Stone And Fitted With Inlet Valve And Air Release Valve. Dummy Plate To Serve As False Bottom During Compaction. Porous Stone For Drainage Base Plate. Porous Stone For Drainage Cap Rubber Connection Tube 3M Long, With Pinch Cock. Overhead Tank, Required For The Constant Head Method Made Of Steel, Approx. 37.5 Cm Dia And 1M High. It Is Provided With An Inlet Port At The Top, Six Outlets At The Bottom With Cocks, Air Inlet And Water Filling Tube At The Top. An Arrangement To Indicate The Water Level Is Also Provided With Rammer 2.6Kgx310 Mm Controll Fall And 4.9Kgx450mm Controll Fall. , Cube Mould, Size: 150 Mm X 150 Mmx 150 Mm (Made Of Cast Iron With Isi Certification) , Cube Mould, Size: 70.6 Mm X 70.6 Mmx 70.6 Mm (Made Of Steel With Isi Certification) , Cylindrical Core Cutter With Steel Dolley, Steel Rammer And Other Accessories. Apparatus Should Consists Of: 1. Cylindrical Core Cutter Of Steel Material Of About 130 Mm Long And 100 Mm In Diameter. 2. Steel Rammer Of About 140Mm.Dia., 75Mm Height And 900Mm (Total Height Including Handle.).Weight Of Rammer Should Be Of 9 To 10 Kg. 3. Steel Dolly 25 Mm High And 100 Mm In Diameter. 4. Palette(Steel) Knife 5. Steel Ruler. 6.Metal Straight Edge. 7. Spade Or Pickaxe.. 8 Apparatus To Extract Core Sample. 9.Moisture Cans(Six Nos. Of Aluminium Material). , Cylindrical Metal Measure (3, 15 And 30 L Capacity) For Determination Of Specific Gravity Of Coarse Aggregates As Peris 2386 (Part Iii) : 1963 , Density Basket Conforming To Is: 2386(Part-Iii)-1963 For Determination Of Specific Gravity & Water Absorption. It Is Made Of G.I. Wire-Mesh Of Approximate Size 20 Cm Dia X 20 Cm High. Complete With Handle. , Desiccator( 250Mm Dia , Material Pp/Pc) , Digital Flocculator With Six Jar (Standard Jar Tester) Designed For Floc Formation Test In Water Treatment Plant. Uniform Stirring Of Up To 6 Samples Simultaneously. Variable Speed Of 20-100 Rpm. Heavy Duty 1/20Hp Motor With Gear Train Mounted On A Mild Steel Housing. Supported By Six Rods On A Bench. Stainless Steel Stirring Paddlers With Adjustable Height. Locking Collars Or Stirring Rods Permit Adjustment Height Of Paddle Height. Spacing Of 6” (150Mm) Between Rod Permit Uses Up To 1000Ml Beaker. Housing Material: Crc / Ms Sheet Duly Powder Coated. Power Consumption: 220/230V Ac Supply 50Hz Single Phase. Motor: 1/ 20Hp Motor Good Quality. Compulsory: Digital Rpm Meter/Timer/Dc-Drive For Low Rpm Illumination: By Tube Lights (With Choke + Stirrer) Duly Covered By Perspex Sheet Having Control Switch Fitted On The Control Panel. , Digital Planimeter Digital Planimeter- (Specification: Roller Type, Accuracy-(+-) 0.2%(Within (+-) 2/1000 Pulses), Accumulated Measuring Value Maximum 10 Sq.M (Scale 1:1), Measuring Range-A) Maximum Vertical Width 325 Mm,B) Horizontal Roller Rotatant Length-30M, Display Liquid Crystal, 8 Digit Figures. Higher Specification Will Be Preferred.) , Digital Rebound Hammer With Calibration Anvil (For Concrete Compressive Strength Analysis In The Field) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881 202 And Other International Standards. Range:10 To 70N/Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Relbound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Softvware And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided. , Direct Shear Test Apparatus As Per Is 2720 (Part13)-1986 12 Speeds, Motorised Is: 2720 (Part Xiii) Is: 11229 Supplied Complete With Proving Ring And 2Nos. Of Dial Gauge Of 0.01X 25Mm. 2Kn With Dial Gauge 2 Nos.& Compression Tension Proving Ring 2Kn; Type Of Shear : Direct / Residual Measurement, Operation : Motorised The Unit Is Provided With A Turret Type Gear Box To Get 12 Different Constant Rates Of Strain I.E 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min. And Arrangements To Carry Out Residual Shear Strength Tests. Suitable For Operation With 220V, 50 Hz, Single-Phase Supply. It Comprises: - I) Shear Box Assembly (Halves Of The Shear Box 2 Nos),60 Mm Square, Complete With A U-Bracket, Guide Pins And Spacing Screws, Made Of Brass. Ii) Gripper Assembly Consisting Of Two Plain Grid Plates, Two Perforated Grid Plates, One Base Plate And One Loading Pad, All Made Of Brass. Iii) Two Porous Stones, Each 6 Mm Thick, Fitting The Shear Box Iv) Shear Box Housing Of Brass, Complete With Two Ball Roller Strips. V) Loading Unit With Normal Loading Of 3 Kg/ Cm2 On 60 Mm Square Specimen. Vi) Specimen Cutter For A Specimen Size Of 60 Mm X 60 Mm X 25 Mm. Vii) The Unit Is Provided With A Turret Type Gear Box To Get 12 Different Constant Rates Of Strain I.E 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, And 0.0002 Mm/Min. And Arrangements To Carry Out Residual Shear Strength Tests. Surcharge Weights To Attain Normal Stress Of 3 Kg/Cm2 1 Set, Surcharge Weight Set Comprises Of Following Weights : 0.05 Kg/Cm2: 4 Nos.; 0.10 Kg/ Cm2: 1 No.; 0.20 Kg/ Cm2: 1 No.; 0.50 Kg/ Cm2: 3 Nos.; 1.00 Kg/ Cm2: 1 No. 1. Conforming To Is 2720 (Part – 13) Of Latest Edition , Ductility Testing Apparatus As Per Is: 1208 -1978 Ductility Testing Machine (Is: 1208 -1978) For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould (Total Length 75 0.5 Mm, Distance Between Clips 30 0.3 Mm, Width At Mount Of Slip 20 0.2 Mm, Width At Minimum Cross Section 10 +0.1 Mm, Thickness Throughout 10 + 0.1 Mm) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm/Mnt And S Cm/Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. , Electronic Balance, Capacity 2 Kg. Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 2 Kg And Sensitivity As 0.01 G. , Electronic Digital Balance(20Kg/1G) Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 20 Kg And Sensitivity As 1 G. , Electronic Digital Balance(25Kg/1G) Electronic Digital Balance With Optional Battery Back-Up For Use During Power Failure Having Maximum Capacity Of 25 Kg And Sensitivity As 1 G. , Pipe Friction Apparatus The Apparatus Is To Be Used To Measure Darcy’S Friction Coefficient (F) For Fluid Flow Through A Given Pipe. The Apparatus Should Consist Of: • A Centrifugal Pump Of 25Mm X 25Mm With 1/2 Hp Mono-Block Pump (Kirlosker Or Equivalent Make), • Sump Tank (80 Cm X 35Cm X 30Cm, Made Of 2Mm Thick Stainless Steel Sheet) To Collect The Water, • Measuring Tank ( 45Cm X 30Cm X 30Cm, Made Of 2Mm Thick Stainless Steel Sheet) Fitted With Piezometer Tube To Measure The Discharge, • G.I. Pipe Of Internal Diameter 25.4Mm (1) And Isi Marked Control Valve And Regulating Valves To Be Provided To Circulate Water, • Bye-Pass Line Is Also To Be Provided Along With Regulating Valve To Regulate The Discharge, The Apparatus Should Consist Of Three G.I. Pipes Of Internal Diameter ½”, 3/4 & 1” Respectively. The Pressure Tapings Are Provided 100Cm Apart On Each Pipe. Each Tapings Are Connected To The Mercury U Tube Manometer To Measure Head Difference. Hand Shuts Valves Are To Be Provided At Each Pipe Inlet And Outlet To Control The Supply In The Pipe. The Tanks And All Other Ms Fittings Should Be Well Epoxy Painted (Both Inside & Outside) To Prevent Rust. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Apparatus And Installation And Demonstration Are To Be Given. , Flash And Fire Point Apparatus Pensky Martens Flash Point (Closed) Tester (Electrically Operated) With Npl Certificate Is: 1448 (Part 21) 1209, Ip 34/58, For Determining Flash Point Of Petroleum Products (Above 490C Flash Point Range). It Has A Brass Coil Cup Fitted With A Heat Resistance Handle. The Cup Is Provided With A Lid Which Includes Stirring Device, A Cover, Shutter And A Flame Explosive Device. The Shutter Is Operated By A Spring Handle. A Flexible Shaft Is Provided In The Hand Operated Stirrer. A Cast Iron Stove Is Fitted With A Metal Top Plate Mounted On An Upright Member (Gas Manifold) And It Feeds A Needle Valve-Controlled Burner Supplied With A Hot Plate. The Energy Regulatory Controls The Heating. Suitable For Operation On 220 V, 50 Hz, Single Phase Ac Supply. Flash Point (Open) And Fire Point Cleveland With Npl Certificate Electrical Heating Thermometer Range: -6°C To +110°C (Low Range), 90°C - 370°C(High Range) Ref. Standards - Is:1448 (Part 69), For Determining The Flash And Fire Points Of Petroleum Products, Except For Fuel Oil And Those Products Which Have Open Cup Flash Point Below 79° C (175° F). Consisting Of Cleveland Flash Cup Brass (Dia. 63 - 64 Mm, Height 32.5 - 34 Mm, With A Filling Mark Is Engraved At A Distance Of 9 To10 Mm Below The Surface Along With An Insulated Handle. Gas Test- Jet Assembly Correctly Positioned And Pivoted From A Cast Cup Platform Which Is Fixed To A Heating Bath. Energy Regulator, To Regulate The Rate Of Rise In Temperature 220 V, 50 Hz, Single Phase, Ac Supply. With Thermometer Ip28c Range: -6°C To +110°C. , Heating Mantle For Bitumen Test As Per Is And Branded , Hot Air Oven Electrically Operated With Digital Indicator Cum Controller With Safety Alarm, Range 50°C To 250°±1°C With Air Circulating Fan, S.S, Inside Size 600 Mm X900 Mm X450 Mm , I.S. Sieves[For Aggregate (Coarse And Fine Aggregates & Soil] 1. Sieve G.I. Frame Material Of Construction: G.I; Protective Coating : Powder Coating; Weight: Preferably 800Gm- 900Gm; Wire Mesh Preferably Imported Quality Size: 100Mm, 80 Mm, 63Mm, 50Mm, 40Mm, 31.5 Mm, 25 Mm, 20Mm, 16 Mm, 12.5Mm, 10Mm, 6.3Mm, 4.75Mm, [Bis:460 Part I & Ii 1985, Reaffirmed 2008] ; Pan And Cover For 30Cm Dia Sieves Material Of Construction: G.I; Protective Coating : Powder Coating Upto 6.3 Mm And The Rest Are Made Of Brass (As Mentioned Earlier) Weight: Preferably 800Gm- 900Gm; 2. Sieve Brass Frame 20Cm Dia Material Of Construction: Brass Type: Seamless Weight: Preferably 250Gm- 350 Gm Wire Mesh Preferably Imported Quality Size: 4.75Mm, 2.36 Mm, 2 Mm, 1.18 Mm, 600 Micron, 425 Micron, 300 Micron, 150 Micron, 90 Micron 75 Micron [Bis:460 Part I & Ii 1985, Reaffirmed 2008] Pan And Cover For 20Cm Dia Sieves With Lid And Pan Conforming To Is:460 Part I 1978; With Brushes For Cleaning Sieve. , Length Gauge Conforms To Is:2386 (Part-I) , Los Angels Abrasion Testing Machine With All Accessories Los Angeles Abrasion Testing Machine With Counter (As Per Is: 10070-1982) , Mechanical Liquid Limit Device With Grooving Tool (Casagrande And Astm), Porcelain Evaporating Dish , Spatula, Palette Knives As Pe Is : 9259-1979. , Piezometer Tube It Consists Of Glass Tube Connected To A Vessel At Which Static Pressure Is To Be Measured. It Is The Simplest Of All The Manometers. It Is Used To Measure Very Low Pressures. The Shape And Size Should As Per Indian Standard. The Glass Material Should Be Of Good Quality, Virtually Unbreakable And Should Not Show Any Type Of Distortion During Experiment. The Cost Of The Item Should Include Supplying, Installation, And Demonstration. , Plane Table Set 1.Plane Table – It Should Be Well Seasoned, Good Quality Drawing Board Made Of Pine/Teak Wood Having Smooth, Plane Finish On Its Top And Fitted With Ball And Socket Arrangement Of Size 60Cmx50cmx1.5Cm Or 75Cmx50cmx1.5Cm. 2. Plane Alidade – Plane Alidade Should Be Of Metallic (Brass Or Gun Metal) With A Fine Beveled Edge. 3.Spirit Level:- Tubular Level, Which Can Be Placed In To Perpendicular Position. 4. Trough Compass:- Usually 15Cm Long And Provided With Magnetic Needle To Facilitate Orientation Of The Plane Table And To Mark North Direction. 5. U-Frame Plumbing Fork:- Hairpin-Shaped Brass Frame Having Two Arms Of Equal Length One End Of Frame Is Pointed, The End Of The Frame Carries A Plumb Bob. 6. Clamps :- Minimum Four Nos. Of Suitable Size. 7. Tripod Stand:- Should Be Of Standard Size Of Either Aluminium Or Good Quality Wooden Material. 8. Plumb Bob:- Standard Size ,Brass Metal. , Plastic Limit Apparatus Conforming To Is: 2720 (Part V) , Proctor Test Apparatus [Light And Heavy Compaction] Proctor Compaction Test (Modified And Standard) Bis: 2720-Part 7 1974. , Pycnometer For Determination Of Specific Gravity Of Sand And Fine Gravel. Consisting Of A Glass Jar Of 1 Kg Capacity, Complete With Brass Cone, Rubber Seal And Screwed Cap As Per Standard Is: 2386 (Part Iii). , Ring And Ball Apparatus Conform To Is:1205 (Electrically Operated) Ring And Ball Apparatusas Per Is: 1205, , Sand Replacement Apparatus [Large] As Per Is:2720 (Part Xxviii). , Sand Replacement Apparatus [Small] As Per Is:2720 (Part Xxviii). , Survey Umbrella , Shrinkage Limit Apparatus (Supplied With Requisite Quantity Of Mercury) The Apparatus Conforms To Is: 10077, And The Test Is Performed As Per Is: 2720 (Part Vi). The Set Consists Of: I) 75 Mm Square Prong Plate Made Of 3 Mm Thick Acrylic Sheet With Three Metal Prongs. Ii) Stainless Steel Shrinkage Dish 45 Mm In Dia, 15 Mm Deep. , Sieve Shaker, Motorised Having As Tardy Cast Iron Body, The Shaker Has An Inclined Sieve Table Which Can Accommodate A Max Of Seven Sieves Of 200 Mm Dia. An Adjustable Top Clamping Plate Is Provided To Hold The Sieves. The Table Has A Gyratory Motion In Addition To Up And Down Jolting Action. The Operating Gear Assembly Is Enclosed In An Oil Bath Fitted With Transparent Oil Level Indicating Window. Suitable For Operating On 220V, 50Hz, Single Phase Supply. Time Switch Adjustable From 0-60 Minutes; Lid And Receiver For 200 Mm Dia Sieves, Made Of Brass; Adopter For 300 Mm Dia Sieves; , Slump Test Apparatus With Tamping Rod And Base Plate Slump Test Apparatus As Per Is: 7320-1974. , Thickness Gauge As Per Is 2386 (Part I) : 1963 , Total Station Total Station.Telescope: Magnitication : 30X Or Better; Image : Erect; Angular MAsurement: Angular Accuracy : 5 Or Better: Least Count: 1 Or Better; Distance Measurement: Distance Range With Single Prism : 2.2 Kms Or Better (Under Normal Conditions) Distance Without Prism : 270 M Or More Laser Output In Prism Mode Class1 (Safe For Human Eye)Distance Accuracy In Prism Mode: 2Mm 2Ppmxd Or Better General:Display : Dual Face Alpha Numeric Keyboard (Identical Display)Compensator : Type: Dual Axis / Range: 3 Or More. Battery Rechargeable Battery (Operational Time Approx.12 Hrs Or More For Each Battery |2 Nos Battery To Be Supplied| Quick Charger. : Ino.Dust & Water Proof Protection : Ipss Or Better.Optical Plummet : 3X Or Better/Llaser Plummet Weight With Handle & Battery :5 Kgs Or More.Memory Management System With Multiple Data Interfaces As:Internal Memory : Approx 10,000 Points Or More. Plug In Memory Device : Usb Flash Memory. Accessories:Aluminium Telescopic Tripod. : Inosingle Prism Assembly Consisting Of: Inorange Pole, Prism, Target Plate, Spirit Bubble, Tripod All In Carrying Cases.Data Communication Sottware : Lnothe Minimum Tolloving Application Software Should Be Loaded In The Instrument.Topography, Resection, (Setting Out Of Co-Ordinates, Line, Arcs), Area Calculation, Etc. Catalogue Of The Quoted Model To Be Enclosed With The Bid (Without Which Bid Should Not Be Considered For Technical Evaluation, Physical Training To The Respective Institute After Successful Supply, Ater Sales Service Is Also Mandatory As When Required, , Turbidity Meter With Standard Solution Specification For Bench Top Turbidity Meter With Digital Display: Supply, Installation, Commissioning, Functional /Performance Testing, Demonstration, Training And Warrantee From Oem Or Their Authorized Dealer For Bench Top Turbidity Meter With Digital Large Full Colour Touch Screen Display Unit & Easy Data Export System Having Minimum Following Specification And Including Specified Numbers Of Standard Accessories. The Instrument Should Be Operable On 220 V Ac, 50 Hz. Specifications Range Turbidity Range (Ntu): 0 To 4000 Ntu (Nephelometric Turbidity Unit) Range Selection: Automatic Resolution: 0.001 Ntu, Accuracy: ± 2% Of Reading Plus 0.01 Ntu From 0 - 1000 Ntu, ±5% Of Reading From 1000 - 4000 Ntu Or Better Repeatability: ±1% Of Reading Or 0.01 Ntu Whichever Is Greater Light Source: Tungsten Filament Lamp Standard : Designed To Meet Epa 180.1 Response Time: < 15 Seconds Operation And Service Manual Should Be Included With The Main Instrument At The Time Of Supply. Instrument Should Have All The Standard Accessories Like Silicone Oil, Oiling Cloth, Filter Assembly, Sample Cells With Caps , Turbidity Standardization Solution Kit, Calibration Kit, Dust Cover At The Time Of Supply. Instrument Should Be Latest Model And It Should Not Be The Obsolete Model. , Universal Testing Machine (100T) Analogue, Universal Testing Machine As Per Is, Capacity 100T. , Vicat Apparatus Vicat Apparatus With Isi Certification Mark Is:5513 Fitted In Aluminium Box (Is-1727, 2541 (P.2), 2645, 4031) The Mould Is In The Form Of Frustum Of A Cone Having Internal Diameter At Lower And Upper End 70 And 60 Mm Respectively And A Height Of 40 ± 0.2 Mm. Needle For Initial Setting Time Determination: The Needle Is Circular/Rectangular In Cross-Section Having A Cross Sectional Area Of 1Mm².With Flat End.- 3Set Needle For Final Setting Time Determination: Having A Cross Sectional Area Of 1Mm² With Flat One End And A Collar At The Other End Having Dia Of 5 Mm And Needle Projects Beyond The Collar By 0.5 Mm – 3Set Polished Brass Plunger With A Projection At The Upper End For Insertion Into The Movable Rod With Flat Lower End Dia 10 Mm, 50 Mm Long- 3Set Sample Capacity : 400 Gms.( Ordinary Portland, Rapid Hardening Portland, Low Heat Portland)Front Scale Should Be Made With Brass (Can Be Measured From Top And Bottom ) Provided With Standard Bottom Glass Plate For Mould As Per Is Code , Bernoulli’S Apparatus The Self-Contained Experimental Set-Up Is To Be Provided With Water Recirculating Unit, Provided With A Sump Tank, Centrifugal Pump Etc. An Arrangement Is To Be Provided To Conduct The Experiment On Different Flow Rates. Flow Rate Of Water Is Measured With The Help Of Measuring Tank And Stopwatch. Technical Details: • Test Section: Material Acrylic, • Piezometer Tubes: Material P.U. Tubes (7 Nos), • Water Circulation: 0.5. H.P. Pump, • Flow Measurement: Using Measuring Tank With Piezometer, Capacity 25Lts. • Sump Tank: Capacity 70 Lts., • Intel Tank: Capacity 20 Lts., • Stop Watch: Electronics, • Control Panel Comprises Of Standard Make On/Off Switch, Mains Indicator, Etc. • Tanks Will Be Made Of 2 Mm Thick Stainless Steel Sheet. • The Inside Surface Of The Tank And All Ms Fittings And Components Should Be Provided With Corrosion Resistant Paint. • The Whole Setup Should Be Well Designed And Arranged In A Good Quality Painted Structure. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Unit And Installation And Demonstration Are To Be Given Within One Month Of Supply Of Set - Up. , Combined Venturimeter And Orificemeter Apparatus The Apparatus Should Consist Of 2 Pipe Line Emerging Out From A Common Manifold. One Pipeline Contains A Venturimeter, Second Contains An Orifice Meter. The Pressure Taping From The Venturimeter And Orifice-Meter Are Taken To Differential Manometer To Measure Pressure Difference. The Venturimeter And Orificemeter Are Connected In Parallel And Any One Of Them Can Be Put In Operation By Operating Valves Provided At The Upstream And Downstream. The Flow Can Also Be Regulated By Theses Valves. The Set-Up Is To Be A Self-Contained Water Re-Circulating Unit, Provided With A Sump Tank, Centrifugal Pump Etc. Flow Control Valve And By-Pass Valve Are Fitted In Water Line To Conduct The Experiment On Different Flow Rates. Flow Rate Of Water Is Measured With The Help Of Measuring Tank And Stopwatch. Technical Details: • Venturimeter: Material Acrylic/Brass Compatible To 1” Diameter Pipe. • Orificemeter: Material Acrylic/Brass Compatible To 1” Diameter Pipe. • Water Circulation: 0.5. H.P. Pump (Standard Make). • Flow Measurement: Using Measuring Tank, Capacity 40 Ltrs. • Sump Tank: Capacity 60 Ltrs. • Stop Watch: Electronics. • Control Panel Comprises Of: Standard Make On/Off Switch Mains Indicator, Etc. • Tanks Will Be Made Of 2 Mm Thick Stainless Steel Sheet. The Inside Surfaces Of The Tank All Ms Fittings And Components Should Be Provided With Corrosion Resistant Paint. • The Whole Setup Should Be Well Designed And Arranged In A Good Quality Painted Structure. 2 Hard Copies Of Operation Manual Are To Be Supplied Along With The Unit And Installation And Demonstration Are To Be Given Within One Month Of Supply Of Set - Up. , Water Distillation Apparatus The Still Is An Essential Part Of Equipment In Modern Material Testing Laboratories. In Operation The Water Is Heated Gently And Converted To Steam By Keeping It Boiling At A Slow Rate. The Steam Is Condensed In An In-Built Condenser And The Distillate Collected In A Receiver. This Is Free From All Impurities And Gases. Cooling Water Consumption 60 Liter/Hr Biological Activity Pyrogen Free Ph 6 -7 Conductivity S/Cm <3 × 10-6 Distillate Temperature 65 - 75?C Copper, Brass, Bronze And Tin Are Used In The Fabrication Of The Stills. The Surfaces Coming In Contact With Water Are Heavily Tinned Which Prevents Metallic Contamination. A Water Inlet Valve Is A Part Of The Still For Connecting To A Tap. An Overflow Is Also Provided To Maintain The Water At Proper Level. The Still Has4 Litre/Hour Distillation Capacity, Suitable For Operation On 220 V, 50 Hz, Single Phase Supply. , Kvl , Kcl Trainer Kit With Adequate Voltmeter Ammeter And Multi Meter , Rlc Resonance Trainer Kit , Analog Micro-Ammeter(0-1000?A) (Ac) , Analog Milli-Ampere(0-1000Ma) (Ac) , Digital & Analog Bread Board Trainer , 8085 Trainer Kit 16 X 4 Line Lcd Display & 101 Pc Key Board. With Power Supply & Rs232c Serial Link Cable, Pc Up/Dn Load Sw, Cross Assembler Etc. , 8255 Study Cum Logic Control Card , 8 Bit Adc & Dac , 8051 Trainer Kit 16X4 Line Lcd Display & 101 Pc Key Board With Power Supply & Rs 232X Serial Link Cable, Pc Up/Dn Load Sw, Cross Assembler Etc. , 8051 Development Board , Stepper Motor & 12V Dc Motor Control With Motor Mounted & Direction Control , 8 Bit Adc & Dac , Lcd Interface Module , Relay Interface Module , Digital Ttl Logic Gate Trainer Kit , Digital Cmos Logic Gate Trainer Kit , Adder/Subtractor Trainer Kit , 4 Bit Multiplexer & De-Multiplexer Trainer Kit , Flip Flop Trainer Kit , 4Bit Shift Register Trainer Kit , Decade Counter Decoder Driver & 7 Segment Display (With 1 Hz Squarer Generator) Trainer Kit , Programmable Counter Using 7490 Ic Trainer Kit , Digital To Analog And Analog To Digital Converter Trainer Kit , Bcd To 7 Segment Decoder Trainer , Ic 555 Trainer Kit , Linear Potentiometer (With Scaling) , Rotary Potentiometer (With Scaling) , C Type Bourdon Tube Pressure Gauge (Spec: 0- 100Psi, Accuracy 1%) , Dead Weight Tester With Bourdon Tube Pressure Gauge , Dead Weight Tester With Bourdon Tube Pressure Switch , Strain Gauge Load Cell , Lvdt Trainer Kit , Hall Sensor Trainer Kit , Piezoelectric Transducer Trainer Kit , Stroboscope , Rtd , Thermocouple , Thermistor , Pyrometer , Manual Installation Of Flow Line Along With The Different Flow Measuring Instruments (Orifice, Venturi, Rotameter, Magnetic Flow Meter, D/P Transmitter) , Conductivity Gage For Level Measurement , Capacitive Gagefor Level Measurement , Gauge Glassfor Level Measurement , Float Typefor Level Measurement , Displacer Typefor Level Measurement , Control Valve , Temperature Control Loop With Using On Off Controller With Temperature Sensor , Complete Set Up Of Process Control Unit For Level & Flow Using Analog Dp Transmitter & Computer Interface With Pid Control Full Set Without Pc. , Complete Set Up For Single Loop Flow Control Unit Using Mass Flow Meter With Control Valve. , Pid Controller Master Unit Containing Analog Pid As Well As Pc Based Pid With Computer Interface Adaptor & Self Extracting Pid S/W On Cd With Process Simulator Panel. , Pcb Stencil Printer , Dc Shunt Motor: ½ Hp, 220V,1500 Rpm (Gee Make)Dc Starter : ½ Hp , 220V, 3-Point Starter, Panel Mount Type, Ammeter : 2A, Mc Type, Panel Mount, 96 Sq. Mm (Ae Make), Voltmeter: 300V, Mc Type,Panel Mount, 96 Sq. Mm (Ae Make), Ammeter: 1A, Mc Type, Panel Mount, 96 Sq. Mm (Ae Make), Rpm Meter: Digital, Panel Mount With Proximity Sensor (Select Make), Rheostat :( 0-50O, 5A, And 0-500O, 1.5A) Screw Motion Type, Cont. Variable, Potential Divider: 500O, 2A Screw Motion Type, Cont. Variac-1No. Motor Are Fitted On Ms Channel Base. All Meters, Starter- Are Mount On Self Stand Bakelite Panel Board. All The Terminals Of The Motors, Meters, Starter, Mcb Etc. Brought Out On The Panel For Flexible Connection With Connecting Patch Cords. , Transformer : 1 Kva, 230V / 115V, 50 Hz Variac : Single Phase, 10A, Input : 230V, Output : 0-270V, 5A, Voltmeter: 300V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 150V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 50V, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), Ammeter : 0-5A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), 0-10A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make) : 0-1A, Mi Type, Class : 1.5, 96 Sq. Mm. (Ae Make), Wattmeter: 300V / 5A, Digital, Pf : 0.2 To 1.0, Class : 1, 96 Mm X 45 Mm (Schneider).All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board.All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords , Variable Dc Source : 0-24V, 0-500Ma, Continuous Variable Dc Source Dc Voltmeter: 0-50V, Mc Type, Class : 1.0, 96 Sq. Mm. Ammeter :0-1A, Mc Type, Class : 1.0 96 Sq. Mm. Load : 0-500Ma, 24V Resistive Load, All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board. All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords , Kelvin Double Bridge:Range Of Measurement: 0.1? – 0.92?, One Digital Galvanometer Provided To Indicate The Balance Conditions. Required Patch Chords Are Provided. Input Voltage :15V Dc Output Voltage :5V Ac, Output Current :1 Amps, Kelvin’S Double Bridge, Patch Cards, 1A Power Supply Adaptor, Manual , Insulation Tester (Hand Driven Generator Type), Rated Resistance: 0-2000 Mohm, Rated Voltage: 500 Volts, Scale Length: 90Mm (Approx.), Rotation Speed: 160 Or More R.P.M , Fluorescent Lamp Set Up With Copper Ballast, Starter, Capacitor Etc. (Philips) Variac : Input :230V Ac, Output : 0-250V, 2A, Panel Mount Type (Penta), Wattmeter : Digital Panel Type, 0-300V / 0-2A (Schneider Make), Voltmeter : Digital Panel Type. 0-300V Ac (Select Make) – 3 Nos. Ammeter: Digital Panel Type. 0-2A Ac (Select Make),All Mount On A Self Stand Bakelite Panel Board. All The Terminals Of Each Inst. Brought Out On The Panel.Connecting Patch Cords, Dp Mcb, Indicator. , Wien Bridge: Supply:- ±12V D.C. At 100Ma, Ic Regulated Power Supply Internally Connected1khz Sine Wave Oscillator Audio Amplifier And Speaker For Null Detection Three Decade Resistances, Single Dial In Steps Of 100 Ohm, Total 1K Each,Two Dials Of 10 Ohm & 100 Ohm, Total 1100 Ohms To Form Arms Of Bridge Decade Standard Capacitance, Selectable By A Band Switch To Form The One Arm Of The Bridge Unknown Capacitor And Adequate No. Of Other Electronic Components Mains On/Off Switch, Fuse And Jewel Light The Unit Is Operative On 230V ±10% At 50Hz A.C. Mains Adequate No. Of Patch Cords Stackable From Rear Both Ends 4Mm Spring Loaded Plug Length ½ Metre Good Quality, Reliable Terminal/Sockets At Appropriate Places On Panel For Connections/Observation Of Waveforms , Maxwells Inductance Bridge: Four Arms Are Provided With Suitable Connectors, 1 Khz Oscillator Of Fixed Amplitude To Feed The Input To The Bridge, Measurement Range 15Mh – 200Mh, Connector Facility Given To View The Output Of The Bridge Externally By Cro, Patch Chords, Input Voltage 15V Dc, Output Frequency 1Khz, Output Voltage 2V Ac, Output Current 0.5 Amps, Patch Cords, 1A Power Supply Adaptor. , Schering Bridge: Built In Dc Power Supplies Fixed. Operated On Mains Power 230V, 50Hz +10%, Sine Wave Generator: 0-1Khz Sine Wave Oscillator, Null Detector: Speaker, Componentsmounted On The Panels : Arm, R1 Four Decades Of Resistance 1 Ohm To 10K Ohm Through Rotary Switch. Arm, R2 Six Different Values Of Resistance Through Rotary Switch. Arm, Cx Three Different Values Of Unknown Capacitance Through Rotary Switch.One Arm Asfixed Capacitor. , Scr- Trainer Kit: Variable Dc Source: 0 ~ ±250V, 0.75A, Variable Dc Source: 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , Diac And Triac-Trainer Kit: Variable Dc : 0 ~ ±250V, 0.75A, Variable Dc : 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , R, Rc And Ujt Triggering Circuits Of Scr-Trainer Kit: Ac Source: 24V, 1A, Lamp/Resistance Load, Test Points Digital Voltmeter: 0 ~ ±230V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Single-Phase Halfcontrolled And Full Controlled Rectifierr And Series R-L Load - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating, Pulse Transformer Firing, Ac Source: 24V, 1A R/R-L Load, Test Points,Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Study Of Step-Up And Step-Down Chopper (Effect Of Variation Of Duty Cycle On Output Voltage In R And Series R-L Load.) - Trainer Kit: Microprocessor Based Pwm Generator Carrier Frequency – 1Khz, 5Khz, 20Khz Pwm Variable From 0 ~ 100% In 1024 Steps, Rectifier, Dc Source: 0 ~ 24V, 1A R/R-L Load, Test Points , Study Of Single-Phase Half Bridge And Full Bridge Square-Wave Inverter In R And Series R-L Load. - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating Pulse Transformer Firing,Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode,Test Points, Digital Voltmeter: 0 ~ ±230V. Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) ,Printed Board, Fuse,Patch Cord , Study Of Single-Phase Ac Voltage Regulator: Ramp Generator, Pulse Train Gating Pulse Transformer Firing, Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode, Test Points, Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable), Universal Motor:- 1/6Hp With Digital Tachometer For Speed Measurement. Printed Board, Fuse, Patch Cord , Speed Control Of Dc Motor Using Chopper - Trainer Kit: All Test Points Are User Connectable Dc Motor 220V-2 A-1/4 Hp-1500Rpm With Loading Arrangement, Contact Type Digital Tachometer With Starter And Dc Power Supply For Chopper Configuration, Panel Mount Ammeter And Voltmeter, Full Converter Operation For Different Firing Angles, Provision For Connecting Freewheeling Diode, On/Off Switch, Thick Patch Cords For Power Circuit, Indicator, Field Circuit Indicator, Printed Board, Fuse, 4 Quad, Duty Cycles 20-70%, Arm Feed Back Symmetrical Angle Control 250 Vdc Built In Supply, I/P-230 V Ac Mains Rectified To 300 Vdc, Duty Cycle- 20 To 70 %. At 50 Hz O/P Voltage- 25 V To 250V , Diac And Triac-Trainer Kit: Variable Dc : 0 ~ ±250V, 0.75A, Variable Dc : 0 ~ ±10V, 100Ma, Digital Voltmeter: 0 ~ ±500V (Peak/Instant), Digital Voltmeter: 0 ~ ±20V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) Digital Ammeter: 0 ~ ±20Ma, Lamp/Resistance Load, Test Points , R, Rc And Ujt Triggering Circuits Of Scr-Trainer Kit: Ac Source: 24V, 1A, Lamp/Resistance Load, Test Points Digital Voltmeter: 0 ~ ±230V Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Single-Phase Halfcontrolled And Full Controlled Rectifierr And Series R-L Load - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating, Pulse Transformer Firing, Ac Source: 24V, 1A R/R-L Load, Test Points,Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) , Study Of Step-Up And Step-Down Chopper (Effect Of Variation Of Duty Cycle On Output Voltage In R And Series R-L Load.) - Trainer Kit: Microprocessor Based Pwm Generator Carrier Frequency – 1Khz, 5Khz, 20Khz Pwm Variable From 0 ~ 100% In 1024 Steps, Rectifier, Dc Source: 0 ~ 24V, 1A R/R-L Load, Test Points , Study Of Single-Phase Half Bridge And Full Bridge Square-Wave Inverter In R And Series R-L Load. - Trainer Kit: Zero Crossing, Ramp Generator, Comparator, Pulse Train Gating Pulse Transformer Firing,Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode,Test Points, Digital Voltmeter: 0 ~ ±230V. Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable) ,Printed Board, Fuse,Patch Cord , Study Of Single-Phase Ac Voltage Regulator: Ramp Generator, Pulse Train Gating Pulse Transformer Firing, Ac Source: 24V, 1A, R/R-L Load, Freewheeling Diode, Test Points, Digital Voltmeter: 0 ~ ±230V, Digital Ammeter: 0 ~ ±500?A/500Ma (Selectable), Universal Motor:- 1/6Hp With Digital Tachometer For Speed Measurement. Printed Board, Fuse, Patch Cord , Speed Control Of Dc Motor Using Chopper - Trainer Kit: All Test Points Are User Connectable Dc Motor 220V-2 A-1/4 Hp-1500Rpm With Loading Arrangement, Contact Type Digital Tachometer With Starter And Dc Power Supply For Chopper Configuration, Panel Mount Ammeter And Voltmeter, Full Converter Operation For Different Firing Angles, Provision For Connecting Freewheeling Diode, On/Off Switch, Thick Patch Cords For Power Circuit, Indicator, Field Circuit Indicator, Printed Board, Fuse, 4 Quad, Duty Cycles 20-70%, Arm Feed Back Symmetrical Angle Control 250 Vdc Built In Supply, I/P-230 V Ac Mains Rectified To 300 Vdc, Duty Cycle- 20 To 70 %. At 50 Hz O/P Voltage- 25 V To 250V , Simple Screw Jack Appratus , Worm And Worm Wheel Appratus , Double Purchase Crab Winch Appratus , Horizontal And Inclined Plane Friction Slide Apparatus , Haematite Ore (1 Kg) , Copper Pyrites (1 Kg) , Powdered Coal Sample (1 Kg) , Tlc Uv Cabinet , Hot Plate With Magnetic Stirrer , Magnetic Stirrer , Digital Muffle Furnace (220-230V, 900°C) , Sample Cells (Round Glass, 10 Ml) , Sample Cells (Square Glass, 10 Ml) , Chloroscope , Air Compressor , Digestion Vessels (12 Pieces Box) , Block Heater , Ampule Sealer , Borosilicate Culture Tubes (16Mm×100Mm×150Mm) With Tfe Lined-Screw Caps , Parafilm Tape , Determine The Permeability Of Magnetic Materials By Plotting Its B-H Curve. Trainer Operated On 230V With 10% Variation, Sufficient Number Of Patch Cords, With Computer Lead, 12 X 8 With Shock-Proof Ply Box, Three Different Values Of Capacitors Are To Be Given On Board. • One Variable Potentiometer • Different Circuit Diagram Is Printed On Board. • Step Down Teansformer With Demonstration Transformer With 2 Secondary Coils And One Primary Coil. • Output Through Bnc Connectors And Bnc Lead Are To Be Provided For Output To Cro. • Components Mounted On The Front Panel. , Set Up For Measurement Of Voltage Current And Power Variable Ac Supply: 0-230V, 0-5A, Continuous Variable Ac Supply, Ac Voltmeter: 0-300V, Mi Type, Class : 1.5,Ammeter : 0-5A, Mi Type, Class : 1.0 96 Sq. Mm. (Ae Make), Wattmeter:230V,5A, 1000Watt, Analogtype, Panel Mount, Load : 0-5A, 220V Resistive Load, Step Variable, All Instruments/Equipments Mount On Self Stand Table Top Type Bakelite Panel Board. All Terminals Of The Meters, Power Source Etc. Brought Out On The Panel Board With Required Mcb, Indicators, Terminals Etc. With Connecting Patch Cords, Operating/Instruction Manuals. , Set Up For Visualization Of Phase Difference Between Voltage And Current In Series R-L And Series R-C Circuit Analog Meters: Ammeter 20Ma Ac.Voltmeter 20V Ac. Components Are Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch. Dso- 2Channel, 50Mhz Table Top-1No. , Measure Voltage, Current, Power, P;Ower Factor In A R-L Series Circuit Resistance: 0 - 500O / 2A, Step Variable, Inductance: 0-200Mh / 2 Amps, Step Variable, Voltmeter: 0-300V Ac, Digital Panel Type– 4 Nos.Variac: 0-250 Volts / 4 Amps, Panel Mount Type, Single Phase, Ammeter ; Digital Panel Type. 0-2A Ac Wattmeter:- 230V/5A, 1000Watt Digital Panel Mount, All The Meters Mount On Bakelite Panel Board With Toggle Switches, Terminals, Connecting Wires, Rotary Switches, Sockets, Operating Manual Etc. , Identify Different Parts Of A Single Phase Transformer, Ac And Dc Motor. Dc Machine-0.5Hp, 220 Volts, 1500 Rpm, Compound Wound Dc Machine. Parts I.E. Armature, Shunt Field, Series Field, Commutator, Carbon Brass, Carbon Holder, Carbon Rocker, Ball Bearing, Bearing Lubricant, Bearing Guards, Cooling Fan Etc. Are Properly Paints And Marking For Easy Understanding. Three Phase Induction Machine (Squirrel Cage)- 1 Hp Capacity, 415 Volts, 1460 Rpm, Three- Phase Sq. Cage Induction Motor. All Parts I.E. Stator Winding, Sq. Cage Rotor, Cooling Fan Are Properly Paints And Marking For Easy Understanding. (Each Set) Transformer (1-Ph) : 1 Kva, Primary : 220 Volts, Secondary : 110 Volts, Single Phase, 50 Hz, An Cooling– 1 No. , Determine The Transformartion Ratio Of A Single Phase Transformer And Measure No Load And Full Load Current Transformer : 1 Kva, Primary : 220 Volts, Secondary : 110 Volts, Single Phase, 50 Hz, Normally Air Cooled, Variac:Single Phase, Panel Mount Type, 0-250 Volts, 10 Amps, Wattmeter : 0-300 Volts / 0-5 Amps, Single Phase, Digital Type (Schneider), Voltmeter: 0-300 Volts, Ac, Panel Mount, Digital Type (Select)– 2 Nos. Ammeter: 0-1 Amps, Ac, Panel Mount, Digital Type (Select) Ammeter: 0-10 Amps, Ac, Panel Mount, Digital Type (Select) – 2 Nos. Load : 0-5A, 220V Resistive Load, Step Variable,– 1Set. All Meters Are Mount On A Self Stand Bakelite Panel Board. All The Terminals Of The Meters Etc. Brought Out On The Panel For Flexible Connection. With Connecting Patch Chords, Operating Manuals Etc. , Identification Of Different Active And Passive Lements In A Given Circuit Different Type Of Resistors, Capacitors, Diodes, Zener Diodes, Transistors (Npn & Pnp Type), Transformers, Inductors,Regulator, Op-Amp Ic, Fet, Mosfet Etc. All Above Mentioned Components Fitted On Acrylic Sheet With Proper Marking And Symbol. , Familiarization With Multimeter To Measure The Value Of Given Resistor And To Confirm With Clour Code Digital Multimeter Meeting Iec1010standard. Ce Resistance:- Different Value Resistance (Cfr And Mfr Type)-1No Each. With Colour Code.Inductor :- Different Value Inductor -1No Each. With Colour Code. Capacitor :- Different Value Capacitor -1No Each. With Colour Code. , Use Of Lcr-Q Meter To Measure The Value Of A Given Capacitor And Inductor • Dual Backlit Lcd Display. Auto Lcr Smart Check And Measurement. Series/Parallel Modes Are Selectable. • Ls/Lp/Cs/Cp With D/Q/ T/Esr Parameters. Support Dcr Mode 200.00O~200.0M?. Five Different Test Frequency Are Available: 100/120/1K/10K/100K Hz. • Test Ac Signal Level: 0.6Mvrms Typ. Test Range: (Ex. F=1Khz). L: 200.00 ?H ~ 2000.0 H. C: 2000.0 Pf ~ 2.000 Mf. R: 20.000 O ~ 200.0 M?. • Multi-Level Battery Voltage Detector Support. Back-Light & Buzzer Sound Driver. • Parameters Displayed: Dc Resistance, Serial Inductance, Parallel Inductance, Serial Capacitance, Parallel Capacitance, Serial Resistance, Parallel Resistance, Phase Angle, Equivalence Serial Resistance, Dissipation Factor, Qqquality Factor. Capacitor:- 2.5Mfd, 2.25Mfd/400Volt-1No. Each. Inductor:- 10Mh, 4.7Mh. -1No. Each. , Test The Pn Junction Diode Using Digital Multimeter And Finding Out Their V-I Characteristics In Forward Bias. Ammeter:15Ma/150Ua Dc Panel Mount-1No., Voltmeter: 3V/30V Dc Panel Mount-1No. Power Supply: Dc Supply Ic Regulated 0-3/30V Dc, 150Ma-1No. Components Are Fixed On The Kit. Silicon Diode _1N4007)-1No., Germanium Diode-1No.,Two Different Voltage Zener Diode-1No.,Voltage Control Through Potentiometer-1No. Digital Multimeter Meeting Iec1010standard. Ce , Identify The Terminals Of A Transistor Using Digital Multimeter And Calculate Gain In Ce Mode Transistor. Transistor- Pnp And Npn Type-1No. Each., Ammeter:- 15Ma/150Ua Dc Panel Mount-1No., Voltmeter:- 3V/30V Dc Panel Mount-1No. Power Supply:- Dc Supply Ic Regulated 0-3/30V Dc, 150Ma-1No., Digital Multimeter , Realization Of Truth-Table Og Different Logic Gates(Ttl) And Verification Of De-Morgans Theorem . Fixed Dc Power Supply Of 5 V /250 M A. . One Output Indicator For Taken The Observations And Two Toggle Input Selectable Switches For Selects 0 And 1 Logics. . Or Gate, Not Gate, And Gate, I C’ S Are Mounted On The Front Panel. . User Manual And Connecting Leads Are Also Provided With This Instruments.
Contract Date: Dec 30, 2024 Contract Value : 51.88 Lakh
Government Departments No of Bidders 36
West Bengal View Result →
50.
Defence #6886994 AOC
Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date: Feb 25, 2025 Contract Value : 47.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
TenderDetail
Loading tenders