View Bid Results For Rubber And Plastic Processing Machinery Tenders

We found 17 Bid Results related to rubber and plastic processing machinery tenders. You can find Contractor details who won rubber and plastic processing machinery tenders along with contract details in Bid awards announcements section.

Filters
Stage
8
8
1
Tender Publishing Platform
17
State / UT
6
9
3
2
1
1
1
Contract Value
9
1
7
Publish Date
0
0
0
0
0
Sector
8
8
3
1
1
1
1
1
1
Ownership
4
8
4
3
2
Within keyword
Active filters:
Showing 1–1 of 17 tenders matching your filters
1.
Public Administrative Department #10377815 Price Bid
Inviting Tenders For The Collection, Transportation & Processing Of Solid Waste In The Periphery Of Municipal Council Savda Dist. Jalgaon-1 Every Household As Well As Shops, Bhajipala Market, Hotels, Government / Semi-Government Offices, Educational Institutions, Public Offices, Etc. The Garbage From The Commercial Area Was Collected In A Classified Manner ( Separated By Heavy Hail And Dry Garbage ) , Collected And Transported To The Place Permitted By The Municipal Council As Per The Scriptures. 2. Public Waste Cistern, City Garbage Dump, Sewerage System, Etc., Collect Garbage Every Day And Collect Solid Waste As Per The Prescribed Method. Process Of Collecting Solid Waste From Vehicles To The Center And Taking It To The Disposal Site. 3 Savda Municipal Council Group No. Running Solid Waste Processing Center At 1407. Process The Hail Waste According To The Scriptures And Make Paper. Also Sending Dry Waste For Recycling ( Including Employees, Chemicals, Necessary Literature Etc. Expenses ) ( Hail, Dry Waste And Household Hazardous Waste ) ( Providing Services For Operation And Maintenance Of Compost Plant Including Labour, Culture, Machinery Operation, Electricity, Water Etc. ) 4 Charges For Using Equipment At The Solid Waste Processing Center Provided By The Municipal Council. ( Care Repair Co ) Weigh Bridge, Simple Processing Machine, Plastic Bailing Machine ( Aggregate ) 5. Disposal Of Components Like Metal, Plastic, Glass, Rubber, Scrap Paper And Paper Obtained From The Separation Of Dry Solid Waste In The Existing Material Recovery Facility Center At The Solid Waste Project. 6 Olya Kacharyapasun Prepared Central Khatachya Vikritoon Municipal Councils Mobadla 7 Vehicles Provided Through Municipal Council, Mobadla Motha Tractor 8 Vehicles Provided Through Municipal Council Are Replaced By Small Tractors. 9 Train Provided Through Municipal Council Or Vehicle Transfer, Ghanta Gadi 10 Vehicle Provided Through Municipal Council - Jcb ( 2Dx Backhoe Loader ) ​
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 5
Maharashtra View Result →
2.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
3.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
4.
Housing Urban and Rular Development #9488962 Technical Bid
Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto/aboveplinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 10 Foundations, footings, bases of columns, etc. for mass concrete. 11 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. 12 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 13 Columns,Pillars, Piers, Abutments, Posts and Struts. 14 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 15 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 16 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction Of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shall be as follows ; (1)Treatment for masonary & foundation 5 liters per/ 100 sqm. (2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment Of soil along external perimeter of building 7.5 liters/100sqm. (6) Treatment Of soil under apron along external perimter 5 liters/100 sqm. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 20 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 23 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 24 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 30 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 31 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 32 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 37 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 39 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 40 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 41 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 42 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 43 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 44 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 45 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections 46 Cement plaster skirting up to 30 cm height,18 mm thick, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 51 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 52 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [IN FLOORING] 53 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ .90 kg/ 10 sqm) 59 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 63 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 64 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 65 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 66 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 67 Coupler 110 mm 68 Bend 87.5° 110 mm bend 69 Shoe (Plain)110 mm Shoe 70 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 71 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 72 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 73 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 74 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 75 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 76 For vertical surface two coats @ 0.70 kg per sqm 77 For horizontal surface one coat @1.10 kg per sqm. 78 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 79 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 80 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum Water tank 82 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 83 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 84 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 85 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 86 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 87 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 88 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 89 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 90 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 91 Providing and fixing toilet paper holder :C.P. brass 92 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 93 90 mm O.D. 94 110 mm O.D. 95 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 96 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 97 90 mm size 98 110 mm size 99 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.BEND 87.5° 75 mm Shoe 100 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 101 90x90x90 mm size 102 110x110x110 mm size 103 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 104 90 mm size 105 110 mm size 106 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 107 90 mm size 108 110 mm size 109 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 90 mm size 111 110 mm size 112 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 113 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 114 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.cement and testing of joints complete as per direction of Engineer in charge Internal work - Exposed on wall 116 20 mm nominaldia pipes 117 25 mm nominaldia pipes 118 40 mm nominaldia pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 120 15 mm nominal outer dia pipes 121 20 mm nominal outer dia pipes 122 25 mm nominal outer dia pipes 123 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 124 25mm dia, nominal bore 125 32 mm dia, nominal bore 126 40 mm dia, nominal bore 127 50 mm dia, nominal bore 128 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 129 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 130 20 mm nominal bore 131 25 mm nominal bore 132 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 133 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 134 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 137 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 139 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) 140 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 141 Extra for depth of man hole size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 142 Providing and fixing square mouthS. W. Gully trapSP 1 complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 143 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 144 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 146 50mm nominal bore. 147 40mm nominal bore. 148 32mm nominal bore. 149 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 150 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 152 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 153 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 154 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 155 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 156 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 157 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 158 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 159 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 160 5/6 A switch 161 3 pin 5/6 A socket outlet 162 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 163 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 164 Supplying and fixing (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module ) 165 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 168 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 169 Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 170 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 171 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 172 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 173 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 174 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door 176 6 way (4 + 18), Double door 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 178 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 179 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 180 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 181 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 182 40 A 183 63 A 184 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 185 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 188 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 189 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypePower Panel :Incoming -200 Amp MCCB - 1 No.Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No.(Complete as per requirment directed by Project Manager.) 190 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 191 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 192 Supply & fixing of IP 20, Mid Power SMD type LED1*1 square LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 193 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 194 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 195 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 196 size 6 sq mm x 2 core 197 size 70 sq mm x 3-1/2core 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 199 2 X 6 sq. mm (19mm) 200 3½ X 70 sq. mm (32mm) 201 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 202 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 203 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 204 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 205 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 206 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 207 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 208 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 209 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 210 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 211 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 212 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 213 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 214 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 215 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 216 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 217 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 218 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 219 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m HeadTerrace Pump 220 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 221 80 mm dia 222 100 mm dia 223 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 224 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 225 80 mm dia 226 100 mm dia 227 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 228 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 229 80 mm dia 230 100 mm dia 231 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 232 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 233 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 234 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 235 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 236 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 237 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 238 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 239 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 240 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 241 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 242 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 243 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 244 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 245 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 246 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 247 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 248 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 249 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 250 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -1 Set 251 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 252 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 253 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 254 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 255 Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints. 256 Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge. 257 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 258 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 259 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 260 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 261 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 262 Providing & fixing 75mm dia vent pipes.Centrifugally cast (spun) iron socketed pipe asper IS: 3989 263 Providing & fixing of 75mm dia cast iron terminal guard.Sand cast iron S&S as per IS - 3989 264 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500 mm internal diameter 265 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 266 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia all kinds of soil 267 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 268 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 269 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 270 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 271 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 272 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 273 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 274 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal size dia 275 Supply and Installation of 3.0 HP Submersible pump set complete 276 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia 277 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 278 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 279 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 280 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 281 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 282 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 283 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 284 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 285 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG/cm^2 286 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 287 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 288 Steel work welded in built up sections framed work,including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .in grating ,frames,guard bar,ladder,railings,brackets,gates and similar works. 289 Supply and installation testing and commisioning of IP based EPBX system comprising of core switch & 1.2 switches 16 port EPBAX IP 4 trunk 290 Hand set IP 291 Master handset IP 292 Supplying and drawing of UTP 4 pair CAT 6 Lan cable 293 POE (Power over ethernet) 294 1 kva UPS 295 R1 4510 box with key stone 296 6U rack comrax (45x45x35 cm) DVR 297 PDU (Power distribution unit)) 298 Fan 299 Supply, Installation, Testing & Commissioning of Wireless indoor Access Point Combined data rate support Dual 5GHz 4.8 Gbps, 802.11ax, 2.4 GHz/5GHz: 4x4: 455 WiFi 6, data rate upto 2400 Mpbs. Four 2.4 GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have Integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WYLAN policies. The solution should be artifical intelligence based self healing soltion. Bluetooth®LE and toTsensor support Humidity pressure (Wi-Fi SYSTEM)Temperature, should also support Asset Tracking if required in future without any change in Hardware. 300 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 301 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 35 KVA 302 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 35 sq mm x 3-1/2core 303 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 35 sq. mm (32mm) 304 Supply, Installation, Testing & Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G 652.D, G657A1, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly. Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor UV-HDPE Jacket Approved Makes. Derwiser/Nexans Siemen Sistiman 305 Supply, Installation, Testing & Commissioning of 6 Port IU x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummer/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Thes, Panel shall be Powder Coated with Min 12mm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1, IEC-60754-1. Insertion loss <= 0 35 dB. Return Loss >= 50. Attenuation 1310/1550 10 3/0 2 dB/KM. Repeatability <= 02DB 1000 Tunes Mating Cycles, RoHS Complied. Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 306 Supply. Installation, Testing & Commissioning of 24 Port 10 x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummet Glands to close any open entry. Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices. Tube for open fibers. Ties, Panel shall be Powder Coated with Min | 2trm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1. IEC-60754-1, Insertion loss <= 0 35 dB, Return Loss >= 50. Attenuation 1310/1550 03/02 dB/KM. Repeatability <= 0 2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 307 Supply. Installation, Testing & Commissioning of fiber patch cord. LC-LC Spiral steel armored 9/125mm OS2 singlemode round cord (4.0 +/- 0.mm).Duplex approved makes Derwiser/Nexans/Stemon/Systimax 308 Supply. Installation, Testing & Commissioning of Cat 6A, 23 AWG (0 57.003mm) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point Approved Makkes Derviser/Nexans/Stemon/Systimax 309 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack. ISO/IEC 11801 2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C 2 Category 6A, IEC 60603-7 (603-7). Universal 110 Impact Tool & Tooless (Both) Termination, Min 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end Approved Makes Derwiser Nexans Siemon Systimax 310 Supply, Installation. Testing & Commissioning of loaded 24 port CAT 6A UTP. Transparent shutter ack panel, IU height, UL-94V-0, cicar label marks and earthing plug for CAT6A cable termination at rack end No Approved Makes Derwiser Nexans Siemon Systimax 311 Supply, Installation. Testing & Commissioning of Cat6A Putch Cord [TP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm. 1 Meter. Operating Temperature -20 to +60 Deg C Patch cord | Mtr for rack side swatch to jack panel connectivity Approved Makes. Derwiser/Nexans/Stemon/Systimax 312 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm, 3 Meter. Operating Temperature -20 to +60 Deg C Patch cord 2 Mtr for rack side switch to end user connectivity Approved Makes Derwiser Nexans/Siemon/Systimax 313 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone TypeShuttered Faceplates for 1/0 fixing at user side Approved Makes Derwiser/Nexans Stemon/Systimax 314 Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans, 2 cable managers, salationary shelf, 2 Nos of hardware pkts Approved Makes Derwiser MIS Rata/APC/APW 315 Supply, Installation, Testing & Commissioning of 22 U floor mount rack with fans. 2 cable managers satationary shelf. 2 Nos of hardware pkts Approved Makes Derwiser/MTS/Rital/APC/APW 316 Supply, Installation. Testing & Commissioning of 15t/ wall mount rack with fans, 2 cable managers. satationary shelf. 2 Nos of hardware pkts Approved Makes Der Wiser/MIS/Rittal/APC/APW 317 Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 12 Tbps, forwarding performance of 1000 Mpps with 24x 1/10G SFP+ ports expandable to 40 SFP+ ports with 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, Stacking/Virtual Chasis support upto 9 Switches with bandwidth 140 Gbps, 64K IPv4 and IPv6 Routes and 30K multicast routes MAC Address 250K, Jumbo frame 9000 bytes should support Routing protocols (KIPng OSPF v3, IS-IS v6, BGPv6) with 1 year support Should be Common Criteria/NDPP/NDCPP certified & IPv6 Logo Certified OEM should be Leader in Forrestor SDN & Gartner Data Centre latest report Approved make - Cisco / Juniper / Impulse / Nexxus/Arista 318 Supply, Installation, Testing & Commissioning of 12 Port POE+ Access Switches with switching capaticy of 200 Gbps, forwarding performance 150 Mpps, having 24 x 10/100/1000BASE-1 Pol-plus(RJ45) with minimum PoE budget of 370 W, with 4 x 10G SFP+ uplink ports Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address Should have Static Routing. Neighbor discovery, system logging. Telnet, SSII, SNMP, Network Tune Protocol (NTP), Domain Name System (DNS) and IPv6 features from day I and should support OSIF, VRRP, OSPFv3 and PIM Approved make - Cisco/Juniper / Impulse/Nexxus/Arista 319 Supply, Installation. Testing & Commissioning of fiber Modules 10G BASE Approved Make Cisco/Juniper / Impulse/Nexxus/Ariste 320 Supply. Installation, Testing & Commissioning of Wireless Indoor Access Point Combined data rate support Dual SGHz 4.8Gbps, 8021lax, 24 GHz/5GHz 4x4 4SS WiFi 6, data rate upto 2400 Mpbs. Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omn: Bluetooth Antenna Transmit Beamforming and Maxımal Ratio Combining the WLAN Access Point solution should have integriaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and 1 honeypot Access Point detection, able to create WxLAN policies The solution should be artifical intelligence based self healing soltion Bluetooth LE and loTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware Omni-directional Bluetooth Antenna, superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support Operating temp 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse/Nexxus/Arista 321 Supplying Installation Testing & Commissioning of Wifi & Dual Band Ax 1800 (WAVE2, MU MIMO, 802 11AX (2x2)) with 2 5 Gbps Poe+ Port Mesh Access Point as required at site. Approved Make Cisco/Juniper / Impulse/Nexxus/Arista/Netgear 322 Supply. Installation, Testing & Commissioning of Wireless Controller Should be Artificial Intelligence (AI) driven Microservices based architecture. The Solution should support 802.11ac primarily and should be backward compatible to 802 | In/a/b/g The solution should also support 802 | lax with Guest Portal support, support WIPS, Rouge AP detection and Honeypot AP detection, able to provide insights based on Time to connect, successful connect, coverage, capacity, AP Uptime, Roaming and throughput able to integrate with varous authentication mechanism including the RADIUS servers, able to handle interference and shift the communication on another channel automatically if, needed, support Dynamic Packet capture to enhance troubleshooting Microservice based Architecture should be scalable to handle around 5000 APs or more in future, Should have a virtual assistant to troubleshoot deeper and facilitate investigation of existing or future issues in the Wi-Fi network Artificial Intelligence feature should be manageble from Wireless to Switching devices Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse / Nexxus/Arista 323 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 324 ANGLE IRON90*90*6 mm 325 T-SECTION 90*90*6 326 HOLD FAST40*6 FLAT 327 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. G.I. Pipe(80 MM DIA)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
5.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
6.
Housing Urban and Rular Development #9475738 Technical Bid
Tender For Construction Of Administrative Block Cyber Thana At Ambedkarnagar -Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavation in foundation in ordinary soil (loam clay or sand) inluding lift upto 1.5 metres and lead upto 30 metres & including filling, watering & ramming of excavated earth into the trenches or into the spacebetween the buildings & the sides of foundation trenchesor into the plinth and removal & disposal & surplus earth as directed by the Engineer-in-charge upto a distance of30 m from the foundation trenches 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping eFoundations, footings, bases of columns, etc. for mass concrete.tc. and removal of form for all heights : 10 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. : 11 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 12 Columns,Pillars, Piers, Abutments, Posts and Struts. 13 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 14 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 15 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 16 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 19 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :R.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete) 20 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : R.C.C. columns in 1:1.5:3 having strength not less than M-20. 21 Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 23 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 24 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 28 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 29 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 30 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 31 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 32 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 33 Supply & fixing of flush Doors commercial quality Conforming to 1.S. 2202 Part I (1983) Including fixing of wooden cleats & stoppers and including fixing and adjustment of hinges. Bolts locks, handles,springs. Fitting with necessary screws to be supplied departmentally. 35 mm thick 34 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 35 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 37 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 38 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 39 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 40 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 41 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 42 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height includingcleaning (b)Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. the surface beforetreatment.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 43 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 44 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 45 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 46 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 47 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 12 mmthickcementplasterindado/ skirting in 1:3 consisting of one part of cement and 3 partsof aprovedcoarsesand laid inpanels,finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials labour T & P etc. required forpropercompletionofthe work. 51 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size ) laid in one layer finished with a floating coats neat cement (40 mm thickfloor). 52 Making groove 10x12 mm widex 8 mm deep in plaster of the wall or in ceilling vertically or horizontally as required AND .Add for groove in plastered surface or moulding to R.C.C. projections 53 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 54 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 55 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] 56 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete 57 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levelsGranite of any colour and shade Area of slab upto 0.50 sqm 58 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 59 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 60 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 61 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 62 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 63 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 64 ainting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 65 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 66 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 67 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 68 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 69 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 70 Coupler 110 mm 71 Bend 87.5° 110 mm bend 72 Shoe (Plain) 110 mm Shoe 73 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 74 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. 75 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 76 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 77 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 78 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 79 For vertical surface two coats @ 0.70 kg per sqm 80 For horizontal surface one coat @1.10 kg per sqm. 81 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 82 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 83 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 84 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg /cum Water tank 85 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 86 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 87 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 88 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 89 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 90 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 91 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 92 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 93 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 94 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 95 90 mm O.D. 96 110 mm O.D. 97 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 98 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 99 90 mm size 100 110 mm size 101 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 102 75 mm Shoe 103 110 mm Shoe 104 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 105 90x90x90 mm size 106 110x110x110 mm size 107 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 108 90 mm size 109 110 mm size 110 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 111 90 mm size 112 110 mm size 113 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 114 90 mm size 115 110 mm size 116 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 118 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 119 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 120 20 mm nominal outer dia pipes 121 25 mm nominal outer dia pipes 122 40 mm nominal outer dia pipes 123 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 124 15 mm nominal outer dia pipes 125 20 mm nominal outer dia pipes 126 25 mm nominal outer dia Pipes 127 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 128 25mm dia, nominal bore 129 32 mm dia, nominal bore 130 40 mm dia, nominal bore 131 50 mm dia, nominal bore 132 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 133 25 to 40 mm nominal bore 134 50 to 80 mm nominal bore 135 Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore: 136 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) 137 20 mm nominal outer dia pipes 138 25 mm nominal outer dia pipes 139 32 mm nominal outer dia pipes 140 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 141 20 mm nominal bore 142 25 mm nominal bore 143 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:893115mm nominal bore 144 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.15 mm nominal bore 145 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 146 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 147 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 148 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 149 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 150 S/F of upvc SWR Pipe Type -B confirming to IS -13592 incluiding jointing the pipes with rubber ring lubricant and UPVC SWR Cuplar confirming to IS 14735 also inluiding excavation of treches cutting of walls and holes and repairing of walls , floors and refilling the trenches as before cut including cost of other fittings such as door band, T and YT including supply of all materials labour and t&p required for prper complition of the work.150mm dia SWR Pipe 151 Haunching of SWR Pipes with cement concrete in 1:2:4 (1 cement: 2 coarse sand : 4 Stone grit 20mm nominal size) with a complete section of size 300x300mm around the pipe. Including supply of all materials and Labour complete. 152 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 153 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75i) For Sewer Line 154 (b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame. 155 Extra for depth of man hole size 90x80 cm 156 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia 157 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design180 x 150 mm. size P type 158 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 159 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 160 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 161 50mm nominal bore. 162 40mm nominal bore. 163 32mm nominal bore. 164 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 165 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 166 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 167 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 168 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 169 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 170 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 171 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 172 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 173 Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 174 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 175 5/6 A switch 176 3 pin 5/6 A socket outlet 177 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 178 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 179 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 180 Supplying and fixing 1 or 2 Module (75mmX75mm), GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 181 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 182 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 183 Installation of Upto 450 mm sweep exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 184 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 185 Supplying and drawing 2 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 186 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 187 Supplying and drawing of 1 run of cable UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 188 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 189 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 190 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 191 4 way (4 + 12), Double door 192 6 way (4 + 18), Double door 193 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG 194 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 195 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 196 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 197 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 198 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 199 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 200 40 A 201 63 A 202 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 203 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 204 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 205 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 206 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 207 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type Power Panel : Incoming - 200 Amp MCCB - 1 No. Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No. (Complete as per requirment directed by E/I) 208 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 209 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 15 to 18 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 210 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 211 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 212 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 213 size 6 sq mm x 2 core 214 size 70 sq mm x 3-1/2core 215 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 216 2 X 6 sq. mm (19mm) 217 3½ X 70 sq. mm (32mm) 218 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 219 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 220 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 221 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 222 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 223 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 224 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 225 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 226 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 227 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 228 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 229 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 230 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 231 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 232 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 233 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 234 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 235 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 236 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace Pump Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 450 lpm at 35 m Head ipes & Accessories : 237 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 238 80 mm dia 239 100 mm dia 240 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 241 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 242 80 mm dia 243 100 mm dia 244 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 245 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 246 80 mm dia 247 100 mm dia 248 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 249 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 250 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 251 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) 252 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 253 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 254 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 255 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 25 sq mm x 3-1/2core 256 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 257 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 258 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Fire Sand Bucket : 259 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 260 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 261 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 262 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 263 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 264 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 265 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 266 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 267 Control Panels (for Terrace Pump) :Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 268 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 269 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 270 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 271 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. 272 Providing and fixing in position pre-moulded joint filler in expansion joints. 273 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. 274 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 275 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 276 Supplying, installation, testing and commissioning ofL.T. panel fully compartmentalized cubical type sheet clad floor mounted totally enclosed , extensible on both sides, switch board suitable for use on 415 Volts 3-phase, 4 wire, 50 Hz system having required fault capacity, housed with incoming and outgoing, Aluminium bus bars with current rating of 0.8 Amp/sq.mm, interconnection etc. with indication lamps, accessories etc, as required as per specification and schematic diagram as required. (Street lighting Panel) INCOMER:-1 Nos.63 Amps. TPN MCCB(25 KA) 1 Nos.63 Amps. Automatic changeover switch 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses. 1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASS BUS BARS:- 100 Amps. TP&N Aluminium bus bars (25 KA) OUT GOINGS:- 6 Nos.32A TPN, MCB (10KA). 4 Nos. 24 Hr Timer Switch 4 Nos. 32A TPN contactor 277 Supplying, installation & testing of 6.0 m high Octagonal pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 130mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 4Cx16 sq.mm YWY cables and 3x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. Contractor to include the cost ofRCC foundation for pole as per structural detail. 278 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 Protection complete in all respect 279 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.16 Sq mm x 4 Core 280 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring ofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 16 Sq mm x 4 Core 281 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.16 Sq mm MR 282 S.I.T.C. of IP Based EPABX System comprising of core switches and L switch with 10g, 10 Giga SFP modules, industry standard appliance server, cloud based, interprise -grade UC solution, MID/ENTRY Level IP/SIP Phone with dual 1 gig ports, racks,CAT6A cable, patch panels, OFC etc. 283 S.I.T.C. of LAN System comprising of core switches and L switch with 10g, 10 Giga SFP modules WIFIAccess points WIFI controller network management software racks, CAT 6A Cable patch panels OFC etc. , 284 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 285 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 286 Providing & fixing 75mm dia vent pipes. 287 Providing & fixing of 75mm dia cast iron terminal guard. 288 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 560mm internal diameter 289 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 400 mm dia 291 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 292 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, i200 mm nominal size diancluding hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 293 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 294 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 295 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 296 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 297 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 298 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 299 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 300 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 10.1 301 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 302 ANGLE IRON90*90*6 mm 303 T-SECTION 90*90*6 304 HOLD FAST40*6 FLAT 305 G.I. Pipe(80 MM DIA) (DSR-18.12.8)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
7.
Public Administrative Department #9460902 Technical Bid
Tender for phase-2 construction and development work of Dev Van in Vineet Khand, Gomti Nagar Scheme.,1 KIDS PLAY EQUIPMENTS ( ref. senior citizen park) 2 Supplying and Fixing of Standered Multi seater See Saw outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPSS12, Make Fun Play/ Kompain/ Arihant) PSR 3 Supplying and Fixing of Turbo Tower outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPCL35 , Make Fun Play/ Kompain/ Arihant) PSR 4 Supplying and Fixing ofMonkey Climber outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPCL43, Make Fun Play/ Kompain/ Arihant) PSR 5 Supplying and Fixing of Balancing Bridge outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge. (Model No. FPTH41, Make Fun Play/ Kompain/ Arihant) PSR 6 Supplying and Fixing of Four Seater Merry Go Round outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPMR11, Make Fun Play/ Kompain/ Arihant) PSR 7 Supplying and Fixing of7 Ht. FRP Wave Slide outdoor playing equipment including necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPSD51, Make Fun Play/ Kompain/ Arihant) PSR 8 Supplying and Fixing of Frog Bin - FRP outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No.FPDB11, Make Fun Play/ Kompain/ Arihant) PSR 9 Supplying and Fixing of Imperial Bench 4 outdoor playing equipmentincluding necessaryfittings, T&P etc all complete in direction of engineer in charge.(Model No. FPGD11, Make Fun Play/ Kompain/ Arihant) PSR 10 HORTICULTURE 11 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). DSR Horticulture 2020; 2.25 12 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 13 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). DSR Horticulture 2020; 2.8RA 14 Fine dressing of the ground DSR Horticulture 2020; 2.7, RA 15 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. DSR Horticulture 2020; 2.25 16 Plantation Work 17 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) DSR Horticulture 2020; 2.57 RA 18 Hedge Plant /Ground cover 2.57.3 19 Grass Cover 20 Providing & laying Selection no. 1 doob grass turf with earth 50mm to60mm thickness of existing ground prepared with proper level and rammingwith required tools wooden and than rolling the surface with light rollermake the surface smoothen and light watering the same maintenance for30 days or more till the grass establish properly,as per direction of officer in charge DSR Horticulture 2020; 2.34 21 EDGE SHRUBS AROUND STRUCTURES AND PATHWAYS 22 Providing and stacking of Iresine herbstii, of height 20-30 cm. full of branches well developedin 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020;10255 23 Bush Rose in different colour 2 to 3 healthy branch 30 cm and above ht. well developed with8 or more flowers / flower buds in 20 cm Earthen pot / Plastic pot as per direction of theofficer-in-charge. DSR Horticulture 2020;4.90 24 Providing and stacking of Chandni dwarf of height 15-20 cm., well branched in earthen potsof size 20 cm as per direction of the officer-in-charge. s per direction of the officer-in-char DSR Horticulture 2020;8.14 25 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. DSR Horticulture 2020; 6.7 26 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marrypalmar, Cherry Blossom etc. well developed with fresh & healthy bushy infull bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of theofficer-in-charge. DSR Horticulture 2020; 5.12 27 FLOWER GARDEN 28 AlyssumDSR Horticulture 2020; 10.1.1 29 Brachycome 10.1.4 30 Daisy hybrid 10.1.15 31 Dahlia double 10.1.14 32 Salvia Hybrid different colour 10.1.29 33 Gomphrena 10.2.5 34 Kochia 10.2.6 35 Portulaca hybrid 10.2.7 36 Vinca Hybrid 10.2.9 37 Zinnia hybrid 10.2.10 38 CIVIL WORK 39 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil DSR 2023, 2.6 40 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. DSR 2.25 41 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) (PWD SOR 2021/SI-4.1.8) 42 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc for mass concrete DSR 5.9.1 (UP SOR 8.20) 43 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 6.4.2 44 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 13.4.1 45 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 13.46.1 46 Making bajri path including preparation of subgrade, supplying and laying brick aggregate of 50 mm nominal size 7.5 cm deep with blinding material consisting of 12 mm moorum and 12 mm red bajri consolidated with road roller. PWD SOR 2021/ 16.10 47 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but Excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All Work Above Plinth Level DSR 5.33A 48 Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. -Thermo-Mechanically Treated bars.PSR 49 Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete DSR 11.35 50 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR 10.2 51 Providing wood work in frames of / Railing / false ceiling, partitionsetc. sawn and fixed in position with necessary stainless steel screws etc. Sal woodDSR 9.3.1 52 French spirit polishing :Two or more coats on new works including a coat of wood fillerDSR 13.68.1 53 Painting or Vanishing on iron works in small areas or new wood work with One coat of ready mixed priming paint & Two coats of approved superior ready mixed paint of clear syuthetic varnish including supply of all materials, labour and T & P etc. required for proper completion of work. Paint to be used should confirm to the I.S.I. No. 103 1950. DSR 13.67.1 54 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate SOR 2020-21 55 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.3.3 Sanction Rate 56 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.10.3 Sanction Rate 57 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 58 brick ballast 40 mm class 150PWD SOR 59 brick ballast 40 mm class 150 PWD SOR 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) 61 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. PWD 16.64 62 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate, PWD 11.3.1 63 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mmPWD 11.41A.1.3 64 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.11.46.2 65 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.PWD 22.6 66 SEATING 67 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications including, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge PSR ( AYAPPA PHASE 1) 68 DUSTBINS 69 Providing & fixing of Dustbin made in mild steel frame with painting & polish and frame wooden member fixed in m.s. frame including painting polishing as per drawing & design all complete in direction of engineer in charge.PSR REF. from Khargapur 70 EXTERNAL LIGHTING AND ELECTRICAL 71 Supply and fixing of 3500mm decorative ribbed steel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8 & with having for twin nos bracket. The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 72 Supply and fixing of 534 mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore or equivalent repuateted make Ref. Rates Globe Park and Begum Hazrat Mahal Dev. 73 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required sor 2018 E &M708 74 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.DSR5.7(E&M) 2014 75 Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)PWD 711 E-M 2018 SCHEUDLE 76 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.PWD 501,E-M 2018 SCHEUDLE 77 6.00 Sqmm 4 Core (g) 78 25.00 Sqmm 3.5 Core (J) 79 70.00 Sqmm 3.5 Core (M) 80 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.40 A TPN PWD 807 f 81 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mmnominal size) (PWD SOR 2021/SI-4.1.8) 82 Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. .(PWD SOR 2021/SI-4.3.2) 83 PAINTING 84 Painting of graphics on the wall till 2 - 2.5 meter s in height in specific designs and colors as guided by engineer in charge PSR 85 SPEAKER SYSTEM ( REF. FROM BEGUM HAZRAT MAHAL) 86 Supplyinstallationtesting andcommisioning of weatherised Two-Way 5.25 inch (135mm) Coaxial Speaker with Components:• 5¼” highly weather-resistant driver• ¾” soft-dome highly weather-resistant tweeter and can handle 80WPinkNoise PowerHandling(160Wprogram)indirect8Ώ setting, plus built-in 30W 70V/100V multi-tap transformer, should have Fully isolated center chamber for wiring protection, Frequency Response (-10 dB): 55 Hz - 18 kHz; (±3 dB): 65Hz - 16 kHz;PowerRating1:160WcontinuousProgram(2hrs),80W (320W peak), Continuous Pink Noise (2 hrs), 45 W (180W peak) Continuous Pink Noise (100hrs), Maximum Input Voltage: 23.3 V,Sensitivity2:86dB,1W@1m(ave.80Hz-16kHz),Nominal Coverage Angle: 360° horizontal, 160° vertical (primary listening 10°to 50°upfromground),Directivity Index(DI):3.4dB, Maximum SPL 3: 105 dB @ 1m, Low Frequency Driver: 135 mm (5.25in)diameterLFdriver,Kapton™former,35.5mm(1.4in) voice coil, polypropylene cone and polyurethane surround, High Frequency:19mm(0.75in)diameterHFdriverPolyetherimide (PEI) dome. Complete in all respects and as directed by engineer in charge. (JBL/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 87 Supply, installation, testing and commissioning ofAmplifiers for Main Speakers with Four-channel 2400 WattNetwork amplifier withDSPwithClassD/TDtechnology,PowerHandling:4× 2400W @ 4/8 Ohms, 4 × 950 W @ 16 ohms Max power per channel in case of bridge mode / Power managmenet should be 4200watts @ 4 ohms and 4800 watts @ 8ohms,InputSignaltoNoiseRatio >108dB,LoadImpedance Stereo/Dual Mode 2Ω - 16Ω; 70Vrms and 100Vrms 96KHz SampleRate; DSPFeatures:classic/linear-phase/FIRspeaker processing platform with four throughputs; DSP Features: Group control with Raised Cosine MESA EQ asymmetric filters Peak and RMS limiters, Support Multiple make Speaker presets Comprehensiveclockingmanagementsystemwithlowlatency samplerateconversion;ProtectionFeatures:VeryHigh Frequency Protection ,DirectCurrentProtection ,Short Circuit Protection,Temperatureprotectionetc,Eightdual-redundant Dante network audio inputs, 4 Analog Inputs, Control port Certifictaion:CE,ETL(ANSI/UL,CSA),BIS.(Crown/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 88 Supplying,installationTestingandCommissioningof2Cx4sq mmCopperSpeakerCableinPVCConduitofspecifiedmake, complete with all accessories etc complete as as per the attached approved make list and with proper connections etccomplete in all respect as directed by Engineer-in-charge.. 89 Supplying,installationTestingandCommissioningof2x2.5sq mmCopperSpeakerCableinPVCConduitofspecifiedmake, complete as per the attached approved make list and with proper connections etccomplete in all respect as directed by Engineer-in-charge.. MR 90 Supply,Installation,testingandcommissioningofSpeakercagemade of SS Jali for theft protection. complete in all respect as directed by Engineer-in-charge.. MR 91 Supply, Installation,testingand commissioningofPoE Ethernet Controllerwith minimum8programmablebuttonandVolume Control,dual-gang US Decoraor dual-gang EU formfactor, push/rotary encoder, encoder ring, with sleep functionality, supportminimum2LCDscreenhaving64x128pixelsscreen resolution, Configured within Audio Architect via drag-and-drop, powerconsumption300mAmaxat48VDCwithVW-1Rated. (JBL/Bose/TW Audio/L Aucostic) complete in all respect as directed by Engineer-in-charge.. MR 92 SURVILLANCE SYSTEM 93 PLINTH AREA RATES CPWD 2023, Supply installation , testing and commissioning of IP based CCTV system for building security comprising of PTZ/FIXED CAMERA, CABLING , RECORDING , DISPLAY SYSTEM HARDWARE SOFTWARE SUPPORT,FOR EXTERNAL SURVILLANCE 6.10.2 , For two entrances only 94 INTERNAL ELECTRICAL WORKS 95 GATE 96 WIRINGPOINTS 97 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 98 Same as in item no. 1 but for fan. and light duty exhaust fan (AS PER UPPWD -2018) 140 B 99 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 100 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187 A 101 Add for plug point with modular switch & socket in place of piano type switch & socket. (AS PER UPPWD -2018) 187 C 102 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 103 MAINS & SUBMAINS 104 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 105 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221 B 106 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 107 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 108 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 109 12 WAYS CAT-B (AS PER UPPWD -2018) 1025A 110 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 111 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 112 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 113 EARTHING 114 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 115 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 116 CABLES 117 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 2core (AS PER UPPWD -2018) 501 118 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm.(AS PER UPPWD -2018) 504 119 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018) 503 120 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects.(AS PER UPPWD -2018) 1120 121 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 122 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect.(AS PER UPPWD -2018) 1402 123 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 124 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 125 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep (M.R.) 126 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 127 LIBRARY AND SHOP 128 WIRINGPOINTS 129 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 130 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 131 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 132 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187 A 133 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 134 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 135 MAINS & SUBMAINS 136 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 137 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221B 138 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223B 139 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 140 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 141 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 142 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 143 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 144 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B(AS PER UPPWD -2018) 1033 145 EARTHING 146 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 147 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 148 CABLES 149 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 10 sqmm 2core (AS PER UPPWD -2018) 501 150 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 151 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018) 503 152 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 153 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 154 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018) 1402 155 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 156 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 157 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 158 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm M.R. 159 HALL (ELECTRICALINSTALLATIONS) 160 WIRINGPOINTS 161 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 162 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 163 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 164 Add for light / fan points with modular type switches in place of piano type switches (AS PER UPPWD -2018) 187A 165 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 166 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 167 MAINS & SUBMAINS 168 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 169 2 x 4 sq. mm.In 20 mm dia conduit. (AS PER UPPWD -2018) 221 B 170 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018)223 B 171 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 172 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 173 12 WAYS CAT-B (AS PER UPPWD -2018)1025 A 174 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018)1002 175 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018)1010 176 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018)1033 177 EARTHING 178 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . (AS PER UPPWD -2018)703 179 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site.(AS PER UPPWD -2018)721 180 CABLES 181 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc. 182 10 sqmm 2core (AS PER UPPWD -2018)501 183 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 184 10 sq.mm. (AS PER UPPWD -2018)504 185 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 186 10 sqmm 2core (AS PER UPPWD -2018)503 187 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018)1120 188 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018)1122 189 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018)1413 190 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 191 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 192 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm M.R. 193 LIBRARY AND SHOP (ELECTRICALINSTALLATIONS) 194 WIRINGPOINTS 195 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 196 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 197 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 198 Add for light / fan points with modular type switches in place of piano type switches(AS PER UPPWD -2018) 187 A 199 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 200 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 201 MAINS & SUBMAINS 202 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 203 2 x 4 sq. mm.In 20 mm dia conduit.(AS PER UPPWD -2018) 221 B 204 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 205 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 206 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 207 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 208 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 209 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 210 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 211 EARTHING 212 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 213 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 214 CABLES 215 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.10 sqmm 2core 501 216 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 217 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018)503 218 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 219 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 220 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018)1402 221 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 222 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 223 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 224 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 225 GUARD ROOM (ELECTRICALINSTALLATIONS) 226 WIRINGPOINTS 227 Wiring point for light with 1.0 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in heavy gauge rigid steel conduit pipepartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete with 14 S.W.Gcopper earth continuity wire&piano typeswitchetc. complete in all respects. (AS PER UPPWD -2018) 138 B 228 Same as in item no. 1 but for fan. and light duty exhaust fan(AS PER UPPWD -2018) 140 B 229 Same as in item no. 1butfor 5ampplug point with piano type switch & socket etc. (AS PER UPPWD -2018) 141 B 230 Add for light / fan points with modular type switches in place of piano type switches(AS PER UPPWD -2018) 187 A 231 Add for plug point with modular switch & socket in place of piano type switch & socket (AS PER UPPWD -2018) 187 C 232 Supply & fixing of power plugwith20amp 250 volts flush type modular switchand 5 pin 20 amp 250 volts flush type universal modular socket on concealed MS box including supply of all material, labour T&P etc. required for proper completion of work (AS PER UPPWD -2018) 139 A 233 MAINS & SUBMAINS 234 Supply & wiringofsubmainwithFR P.V.C. insulated1100 volts grade singlecorecopper conductorcable in heavygaugerigid steel coduit partly concealedinwall and partly laid inslab alongwith the reinforcement before concreting complete withone no. 14 SWGcopperearth continuity wire complete in all respects. 235 2 x 4 sq. mm.In 20 mm dia conduit.(AS PER UPPWD -2018) 221 B 236 2 x 10 sq. mm.In 25 mm dia conduit. (AS PER UPPWD -2018) 223 B 237 DISTRIBUTIONBOARDS&CIRCUITBREAKERS 238 S/F of surface / flush mounting SPN Distribution board (Legrand Lexic) without MCB complete in all respects as directed at site by Engineer-in-charge. 239 12 WAYS CAT-B (AS PER UPPWD -2018) 1025 A 240 Supply & fixingof 6/10/16/20/25/32 amp. SP MCB (10 KA) (Legrand Lexic) (AS PER UPPWD -2018) 1002 241 S/F of 40 Amp DP MCB (10 KA)(Legrand Lexic) (AS PER UPPWD -2018) 1010 242 S/F of sheet steelenclosure for DP / TP / FP MCB with neutral link and earth terminal. CAT-B (AS PER UPPWD -2018) 1033 243 EARTHING 244 Supply&burryingof 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnelforwatering and one earthing lead ofno. 8SWGG.I. wirein 15 mm dia. GI pipe uptoswitch board (from apron to switch boardthecost of GI pipe & GI wire willbeextra)300mm square C.I. box with hinged cover,masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect .(AS PER UPPWD -2018) 703 245 Supplying & Laying of one number 8 SWG G. I. wirein 15 mm. dia. G. I.pipefor earthing, laidin groundor inwall duly concealedincludingthecostofcement, sand, labour, T&Pandothermaterial required for proper completion ofthework as directed at site. (AS PER UPPWD -2018) 721 246 CABLES 247 Supply andlayingofISI marked aluminiumconductor PVC / XLPE insulated armoured,served,sheathed cable 1100volts gradeat 750mmbelow ground level overacushion of 75 mm thick sand around & protected with brick onsides & top on surfacethecablerunshallbe fixed on M.S. clamps etc. of suitablesize completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor by clamps etc.10 sqmm 2core 501 248 Supplyfixing of plam orpintypecopper tin plated cable socket (lug) tothecable leads, insulating with tapeand making connections etc. complete in all respects as per direction of Engineer-in-charge. 10 sq.mm. (AS PER UPPWD -2018) 504 249 Supply andfixing brass nickle plated compression glandsfor PVC insulated armoured,served,sheathed cable including rubber ring etc.completeinallrespect. The armouring of the cable shall be properlyconnectedwith the earth conductor. 10 sqmm 2core (AS PER UPPWD -2018)503 250 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. (AS PER UPPWD -2018) 1120 251 Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (AS PER UPPWD -2018) 1122 252 Supply & fixing of recess/surface/ pendent mounting round10 to 15 watt LED Down lighter having powder coated die cast aluminium housing with heat silk, diffuser/ reflector and driver set complete in all respect. (AS PER UPPWD -2018)1402 253 Supply & fixing ofLED tube light with batten suitable for upto 1x22 watt LED tube light fittings including tube on surface complete in all respect Cat- AAA (AS PER UPPWD -2018) 1413 254 Supply & fixing of recess/ surface mounting round 24 watt to 32 watt LED down lighter having powder coated die cast alumnium housing with extended heat sink, diffuser / Reflector and driver set completed in all respect. (AS PER UPPWD -2018) 1404 255 Supply ofAC230/250 volts, 50 HZ fresh airfansincluding providingnuts, bolts, mounting frame and other accessories etc.complete(Make : Bajaj / Usha / newtek / Havells) 300 mm sweep M.R. 256 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 257 LIBRARY (PLUMBING WORKS ) 258 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 259 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 260 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 261 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 262 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 263 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps.M.R. 264 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. M.R. 265 HALL PLUMBING WORKS 266 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 267 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 268 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 269 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 270 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 271 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 272 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 273 KITCHENPLUMBING WORKS 274 ACCESSORIES 275 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : PWD 19.7 (DAR17.10) 276 Providing and fixing the taps attached to the shower divertor and the the sink M.R. 277 Providing and fixing the shower heads M.R. 278 Providing and fixing the shower divertersM.R. 279 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 32 mm dia (for wash basin) PWD 17.28.1.1 280 WATER SUPPLY PIPES AND FITTINGS 281 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 282 Internal work exposed on wall 283 40mm nominal outer dia pipes. (PWD 18.75) 284 50mm nominal outer dia pipes PWD 18.9.6 285 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 286 Concealed work including cutting chase and making good the wall etc. 287 15mm nominal outer dia pipes PWD 18.8.1 288 20mm nominal outer dia pipes PWD 18.8.2 289 25mm nominal outer dia pipes PWD 18.8.3 290 32mm nominal outer dia pipes PWD 18.84 291 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 292 40 mm nominal bore PWD 18.17.3 293 50 mm nominal bore PWD 18.17.4 294 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions.DSR 18.21.2.1 295 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. PWD18.49.1 296 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. PWD 18.50.1 297 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931.PWD 18.52.1 298 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. PWD 18.53.1 299 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredRange of four urinal basins with 10 litre white P.V.C. automatic flushing cistern PWD 17.4.4 300 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard designDSR 18.32.1 301 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm. size P type PWD 19.4.2.1 &19.4.2 302 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms DSR 17.70.1 303 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 304 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD 18.48 305 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 306 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) M.R. 307 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 308 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 309 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 310 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 311 50 mm dia. 312 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 313 P-Trap type Floor Trap 110 x 75 mm 314 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 315 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 316 GUARD ROOM AND TOILET BLOCK PLUMBING WORKS 317 ACCESSORIES 318 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : PWD 19.7 (DAR17.10) 319 Providing and fixing the taps attached to the shower divertor and the the sink 320 Providing and fixing the shower heads 321 Providing and fixing the shower diverters 322 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 323 32 mm dia (for wash basin) PWD 17.28.1.1 324 WATER SUPPLY PIPES AND FITTINGS 325 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 326 Internal work exposed on wall 327 40mm nominal outer dia pipes 18.7.5 328 50mm nominal outer dia pipes 18.9.6 329 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 330 Concealed work including cutting chase and making good the wall etc. 331 15mm nominal outer dia pipes 18.8.1 332 20mm nominal outer dia pipes 18.8.2 333 25mm nominal outer dia pipes18.8.3 334 32mm nominal outer dia pipes 18.8.4 335 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 336 40 mm nominal bore 18.17.3 337 50 mm nominal bore 18.17.4 338 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. 18.21.2.1 339 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 18.49.1 340 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms.18.50.1 341 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 18.52.1 342 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931.18.53.1 343 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredRange of four urinal basins with 10 litre white P.V.C. automatic flushing cistern 17.4.4 344 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 18.32.1 345 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm. size P type PWD 19.4.2.1 &19.4.2 346 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms DSR 17.70.1 347 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 348 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD 18.48 349 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 350 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) 351 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste, and vent, Type-B as per IS : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, WC connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. The rubber ring shall confirm to IS:5382. (Make : Supreme / Finolex / Prince) 352 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 353 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 354 Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. (Make : Supreme / Finolex / Prince) 50 mm dia. 355 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 75 mm 356 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 357 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
8.
Housing Urban and Rular Development #9446947 Technical Bid
Tender For Proposed Construction Eco-Tourism Development Of Dhandhraul Dam, Sonbhadra District-Sonbhadra, 1 Proposed Construction Eco-Tourism Development of Dhandhraul Dam, Sonbhadra District-Sonbhadra. 2 Civil 3 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 5 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 6 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 7 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) 8 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 9 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 10 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 11 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands,plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing andreinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). 12 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources) 13 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 3 coarse sand) 14 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 15 Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). 16 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 19 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. 20 Providing and fixing specified wood frame work consisting of battens 50x25 mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete.Kiln seasoned and chemically treated hollock wood 21 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 22 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Raised and cut pointing 23 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 24 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 25 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. 26 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. 27 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 28 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 29 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm 30 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting andfinishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 31 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to |.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 32 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 33 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 34 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 35 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm 36 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :Light shade pigment using white cement 37 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 38 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 39 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)Second class teak wood 40 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes 41 Second class teak wood 42 4 mm thick glass pane (weight not less than 10 kg/sqm). 43 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 44 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 45 (a) Single leaf 46 Both side laminated 47 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 48 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 49 Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface) 50 Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 52 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 53 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 54 French spirit polishing :Two or more coats on new works including a coat of wood filler 55 Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. 56 Providing and fixing of wooden Jali, necessary brass screws etc. to suit shutter thickness complete. 57 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 58 Providing & fixing Stainless steel sliding door bolts with nuts and screws etc complete. (a) 250mm x 16mm . 59 Providing and fixing stainless steel tower bolts (barrel type) with necessary screws etc. complete 60 (a) 300 mm x 10mm 61 (b) 200 x 10mm 62 Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm 63 Providing and fixing at all height false ceiling of 4 mm thick phenol bonded Bamboo Mat board (595x595 mm) conforming to IS:13958-1994 including providing and fixing of frame work made of GI angle 25x25x0.4 mm thick all around suitably fixed to wall with the help of dash fastener and hanger frame (600x600 mm c/c) made GI slotted Tee having powder coating on bottom side (30x25x0.3 mm thick for main member & 25x25x0.3 mm for cross member) connected to ceiling with 2.64 mm GI wire and anchor fastener at every junction and also including cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed all complete as per direction of Engineer-incharge. 64 Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.]. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.|. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per anufacturer’s specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 65 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 66 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 67 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 68 Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) 69 Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) 70 Centering and shuttering including strutting, propping etc. and removal of form for: 71 Foundations, footings, bases of columns, etc. for mass concrete 72 Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick 73 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 74 Columns, Pillars, Piers, Abutments, Posts and Struts 75 Providing and fixing factory made door frame (single rebate) made out of solid foam PVC extruded profile of minimum 60 mm width and minimum 30 mm thickness, having homogenous fine cellular structure and integral smooth outer skin. The frame’s vertical and horizontal members to be mitered cut and joined together with PVC solvent adhesive / cement and both corners strengthened with fully threaded steel screws (of required size) fixed diagonally. The door frame is to be fixed to door jambs using 6 Nos. SS 304 grade minimum 8 mm dia CSK Phillips stainless steel self tapping screws/fasteners with PA6 grade polyamide sleeves both of required size, and gap if any between the door frame and the jamb must be filled with clear silicon, complete as per direction of the Engineer-in-Charge. 76 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (+ 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (+ 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2 mm (+ 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (+ 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge 77 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. 78 Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi point locking system. (Height above 1.8m) 79 French spirit polishing :Two or more coats on new works including a coat of wood filler 80 Float glass panes4 mm thick glass pane (weight not less than 10kg/sqm). 81 ELECTRICAL- 82 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 83 Group - C 84 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 85 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 86 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 87 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 88 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 89 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 90 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 91 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 92 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 93 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 94 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 95 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 96 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 97 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 98 Upto 450 mm sweep 99 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 100 Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 101 Supply of Recess/Surface mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 102 Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). 103 Supply of Recess mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 104 Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect 105 Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. 106 Supplying of 9 Watt Decorative LED Wall Light complete in all respect. 107 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 108 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 109 300mm EXHAUST FAN 110 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 111 4 Way Double door 112 6 way Double door 113 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 114 40 amps TP MCB 115 40 amps 4P MCB 116 63 amps 4P MCB 117 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 118 25 amps 119 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 120 Single pole 121 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 122 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 123 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 124 Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. 125 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 126 Up to 35 sq.mm. 127 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required 128 Upto 35 sq. mm (clamped with 1mm thick saddle 129 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 130 4 x 25 sq.mm 131 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 132 3½ X 25 sq. mm (28mm) 133 Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. 134 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameterand 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cementcomplete as per standard design : 135 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 136 EXT ELECTRIFICATION. 137 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. 138 FEEDER PANEL 139 Incoming : 140 One No 160 Amp. 4P MCCB of 35KABreaking capacity 141 Metering : 142 One (1) No. SetsMultifunction Meter each incoming 143 One (1) No. of Phase Indication Lamp each incoming 144 Bus Bar : 145 One (1) No. 200 Amp.TPN aluminimum bus bar of suitable length. 146 Outgoing : 147 Phase indication lamps on each outgoing to be provided. 148 63 Amps FP MCB of 10KA - 1 No 149 16 Amps DP MCB of 10KA - 15 No 150 2 No. SPACE & SPARE 151 Panel described as above 152 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 153 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 154 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 155 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 156 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 157 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 158 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 159 Up to 35 sq.mm. 160 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 161 3.5 x 70 sq.mm 162 3 x 6 sq.mm, 163 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 164 2 X 6 sq. mm (19mm) 165 3½ X 70 sq. mm (38mm) 166 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 167 100mm dia 168 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 169 90 mm dia (OD-90 mm & ID-76 mm nominal) 170 ProvidingandfixingHT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. 171 Supplying andFixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. 172 Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. 173 Supply and fixing of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. 174 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 175 With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 176 Supplying, installation & testing of 7.0 m high octagonal GI pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 J0) with top diameter as 75mm and bottom dia as 150mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16A SP MCB, loop-in-loop out terminals for 2nos. 2Cx6 sq.mm YWY cables and 2x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. 177 Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 45Watt. to 50 Watt andConfirming to IP66 protectionhaving Company LOGO Engravedcomplete in all respect with 4000-5000 system lumens High Power LED with lenses, >110lm/W, PF>0.95, THD <10% at full load, CRI>70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe 178 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 179 Double pole 180 S & F cast aluminium 4 mtr. Pole for post top light complete as required. 181 Supply and fixing of decorative 30 to 40 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect. Make Havells 182 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect 183 Supply and fixing of 9 Watt LED Inground UpLight luminaire Confirming to IP 66 Protection complete in all respect. 184 Supply and fixing of 3 Watt to 10 Watt LED Step light luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 66 Protection complete in all respect. 185 Supply & fixing of 16 mtr High mast shaft with 8 Nos. 300W LED light of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc, completee in all respect. 186 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 187 1 output per phase and suitable for single phase supply 188 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 189 Above 6.5 metre and upto 8.0 metre 190 Supplying and embedding following dia G.I. pipe (medium class)in pole collar/ foundation (during casting) for cable entryincluding bending the pipe to the required shape complete asrequired 191 32 mm dia 192 Supply, Installation, Testing and Commissioning of LED RGB/RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270V AC, 50Hz with power factor>0.9. Fixture shall be suitable to operate atanambient temperaturerangeof-10°Cto+50°Candshallbe IP65andIK06rated.LifetimeshallbeatleastL70:50000burninghoursat50°C.LuminaireshallbeconformingtoBIS(IS10322)andshallbecompletewithallnecessaryaccessoriesrequiredforproperworkingoffixtureincludingweatherproofconnectioncables,waterproofconnectorsetc. as required. 193 45W /40W 194 PLUMBERING. 195 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 196 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 197 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 198 W.C. pan with ISI marked white solid plastic seat and lid 199 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 200 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 201 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 202 Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 203 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: 204 Kitchen sink without drain board 205 510x1040 mm bowl depth 250 mm 206 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth 207 Granite stone of approved shade 208 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 209 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 210 Flexible pipe 211 i) 32 mm dia 212 ii) 40 mm dia 213 Providing and fixing PTMT Bottle Trap for Wash basin and sink. 214 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 215 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 216 Circular shape 450 mm dia 217 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 218 Providing and fixing toilet paper holder : 219 C.P. brass 220 Providing and fixing soil, waste and vent pipes :100 mm diaCentrifugally cast (spun) iron socket &spigot (S&S) pipe as per IS: 3989 221 75 mm O.D. 222 100 mm O.D. 223 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 224 75 mm 225 110 mm 226 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 227 75 mm O.D. 228 110 mm O.D. 229 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 230 75 mm 231 110 mm 232 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 233 Shoe (Plain) 234 75 mm Shoe 235 110 mm Shoe 236 Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS - 3989 237 75 mm size 238 110 mm size 239 Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 3989 240 75 mm size 241 110 mm size 242 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989 243 75 mm size 244 100 mm size 245 Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989 246 75 mm 247 100 mm 248 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 249 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 250 20 mm nominal outer dia pipes 251 25 mm nominal outer dia pipes 252 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 253 Internal work - Exposed on wall 254 20 mm nominal outer dia Pipes 255 25 mm nominal outer dia Pipes 256 32 mm nominal outer dia Pipes 257 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 258 15 mm nominal outer dia pipes 259 20 mm nominal outer dia pipes 260 Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work 261 40 mm dia, nominal bore 262 50 mm dia, nominal bore 263 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 264 25mm dia, nominal bore 265 Providing and fixing uplasticised PVC connection pipe with brass unions : 266 45 cm length 267 15 mm nominal bore 268 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls) 269 20 mm nominal outer dia pipes 270 25 mm nominal outer dia pipes 271 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 272 20 mm nominal bore 273 Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 274 15mm nominal bore 275 20mm nominal bore 276 25mm nominal bore 277 32mm nominal bore 278 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 279 15mm nominal bore 280 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 281 15mm nominal bore 282 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 283 15 mm nominal bore 284 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 285 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : 286 Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 287 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 288 150 mm O.D. 289 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 290 110/100 mm diameter pipe 291 160/150 mm diameter pipe 292 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 293 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 294 Inside size 90x80 cm and 45 cm deep including C.I. coverwith frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 295 Extra over Item No. 24.27 for every additional depth of 0.10 metre or part there of main hole. 296 (a) Size 900 x 800 mmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 297 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. 298 75 mm 299 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 300 Bend without door (87.5°) 100MM BEBD 301 Bend without door (45°) 100mm 302 75mm 303 Y Fitting without door 100mm 304 75mm 305 Reduced Y Fitting without door 100mm x 75mm 306 Single Tee without door 110mm 307 75 mm 308 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. 309 32mm dia. Pipe Elbow (90°) 310 32mm 45 311 Elbow (45°) 32mm 312 T fitting 32mm 313 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 314 110mm x 75mm x 50mm/40mm (Toilet) 315 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 316 110mm x 75mm (Toilet) 317 FACAD LIGHTING. 318 Supply of 1000mm long rigid architectural Dynamic RGBWLED Linear wall washer light with housing made of Extruded aluminium& die-cast aluminium end caps. The luminaire shall have electrostatically applied polyester powder coating finish.The luminaire’s integrated brackets shall be made of extruded aluminium & the same shall be so designed that the luminaire can be tilted from -90° to +15°. The luminaire shall have IP66 protection.The fixture shall havebeam angleAssymteric beamthe lens shall be made of anti-aging & anti UV PMMA/ PC material.The optical cover shall be made of IK06 rated. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤3. The fixtures shall be installed with IP67 connectors. The luminaire shall have system wattage range between 35-40W and fixture should be operated with 24V IP66 external DC driver for ease of maintenance. Fixture shall be specially designed and able to sustain the operating temperature range of 0°C to 45°C . The luminaire shall have declared life of 35,000 burning hours at L70.The luminaire should have loop in loop out provision for power and DMX Signal.Luminaire shall have 4 DMX channel with Integrated DMX decoder The luminaire shall have class I insulation.The luminaire shall be compatible with DMX512 controller. The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Following certifications/reports to be submitted : product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer and type test reports with BIS certificate.Fixture, driver and other accesories should be of same make.The luminaire shall be supplied with necessary connectors for connecting lead/jump cables & necessary endplates/covers.Philips Color kinetics / Wipro/Iguzzini/Ligman Lighting 319 Supply of Circular shape architectural throw adjustable Dynamic RGBWLED flood light withhousing made of Die-cast aluminium. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall haveproper IP66 protection. The fixture shall have 15 to 60 degree beam angle the lens shall be made of anti-aging & anti UV-PMMA / PC material should be IK06 rated. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤3. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage range 20W-25W . Fixture should be operated with 24V IP66 external DC driver for ease of maintenance. Fixture shall be specially designed and able to sustain the operating temperature range of 0°C to 45°C . The luminaire shall have declared life of 35,000 burning hours at L70.The luminaire should have loop in loop out provision for power and DMX Signal.Luminaire shall have 4 DMX channel with Integrated DMX decoder The luminaire shall have class I insulation.The luminaire shall be compatible with DMX512 controller.The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. Following certifications/reports to be submitted: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer and type test reports with BIS certificate.Fixture, driver and other accesories should be of same make.The luminaire shall be supplied with necessary connectors for connecting lead/jump cables & necessary endplates/covers. Approved Make :Philips Color kinetics / Wipro/Iguzzini/Ligman Lighting 320 Supply of 150W RGBW LED Flood light with System Lumen Output of Minimumwith all channel ON. Fixture shall be made up of Extruded Aluminum Housing for better heat decapitation having IP66 Dust and Water Protection for Outdoor usage. The Luminaire should have multiple beam options of 11/15/30/60° to be used as per design requirement. The luminaire should have loop in loop out provision for power and DMX Signal. Luminaire shall have 4 DMX channel with Integrated DMX decoder. Luminaire should be capable of operating at 24VDC , with External IP66 24Vdc Driver. Luminaire and Driver should be Made in India. Luminare, Driver and controller should be with same make. Wipro Cat Code : LF27 Mega Flood or Equivalent make in Philips and Ligman. 321 Supply of Dynamic Colour Changing 4 Mtr longflexible RGB LED PU Coated Strip light with IP68 protection suitable for outdoor applications. Strip should have 10-14W per meter. The LED Strip should have integrated aluminium C channel for mounting.Fixture should be able to workambient temp range of 0degC to +45degC and should be theft proof type. The LEDs used should be with RGB CCT, the Fixture should have Dotless Homogenous Light source with integrated diffuser as part of striplight for better rugedness and diffused illumination with low glare and DOT free illumination.Luminaire should be capable of operating at 24VDC , Driver, and controller should be with same make. The luminaire shall be compatible with DMX512 controller. Following certifications/reports to be submitted: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer and type test reports with BIS certificate.Fixture, driver and other accesories should be of same make.The luminaire shall be supplied with necessary connectors for connecting lead/jump cables & necessary endplates/covers. Approved Make :Philips Color kinetics / Wipro/Iguzzini/Ligman Lighting 322 DMX 323 Supply of Lighting playback controller with minimum following specifications: • DMX Output- 1024 (2x512, 2Uni.) channels • Input Ethernet (RJ45, DHCP or static IP), USB-C • Networks Ethernet, Internet, WIFI compatible when connected to a router • Multiple Zone 10 Zone, play 10 scene/sequence per time in Stand Alone • Memory o Micro SD Card ( max. 256 GB ) o 8Mb Internal memory (No SD required) • Stand Alone options o Art-Net and sACN from SD card, including triggers (4x512) o Master / Save Synchro (32 max wired / 128 max Ethernet) o Commands from the Contacts (speed, scene, dimmer, zone) o Default start scene, Scene priority, Cross Fade time between scenes o Automatic Scene Recovery if the power is cut off and 16-bit and fine channel management • Triggers options o RS232 In/Out (16 characters max for RS232 triggers, commands or orders) o UDP / Ethernet triggers and commands (from SDK) o Real Time Clock and calendar for each scene (Hour, Day, Week, Month, Year) o 12 smart Contacts on 3~5V (On, On/Off, Release, Restart, Scene Priority, 31 contacts max) Approved Make :Philips Color kinetics / Wipro/Iguzzini/Ligman Lighting 324 Supplyof Amplifier/Splitter with 6-output DMX splitter with DMX signal boosting. This unit takes the incoming DMX signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6X32. Power consumption should not be more than 5W. The Compact signal amplifier shall support optically/magnetic isolation protection, protects the controllers and ensures that the DMX signal can be normally transmitted to various luminaires, improving the reliability and stability of the entire control system. The controller shall be compact in size & shall be minimum IP20 rated. Amplifiershould be able to amplify the signal for up to 200m.The amplifier shall have male-female XLR connectors. On the input & output side the amplifier shall have cable with IP67 6-Pole XLR connector.Housing - MS/AluminumThe output terminals are optically isolated from the input and share a common ground reference. All six output ports have an independent output driver and ELV transformer to boost the DMX signal.1: 6 Way DMX Splitter/Booster ,Optically isolated DMX Input/OutputsIndividual coil transformer for each output , Surface/Rack/Floor/Celling mountable with provide mounting accessoriesRefined and filtered data Cable 3 core 0.75sq.mm cable.Approved Make :Philips Color kinetics / Wipro/Iguzzini/Ligman Lighting 325 Supply of WL-Button 6 Flush-mounting wall panel 6 dry Button panel with a 16 port connection. Button system should have trigger to control light with responsive, reactive programming. Approved Make :Philips Color kinetics / Wipro/Iguzzini/Ligman Lighting 326 Programming Extra 327 HORTICULTURE WORK. 328 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 329 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 330 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 331 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 332 Spreading ofmixed good earth and manure in specified proportions as above and in required thickness. 333 Rough dressing the trenched ground including breaking the clods. 334 Fine dressing the ground 335 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). 336 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 337 officer in charge 338 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-chargeOrdinary rock 339 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) 340 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 341 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 342 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 343 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 344 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 345 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 346 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 347 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 348 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 349 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 350 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 351 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 352 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 353 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 354 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 355 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 356 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 357 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 358 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 359 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, PeruvianaOdissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plasticpots & as per direction of the officer-in-charge. 360 Providing and stacking of Petra volubilis of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 361 M.S. PERGOLA 362 Supply & Installation of wooden Gazebo of specification Shape Pyramid, Waterproof, Material – Wooden, Frame,Finishing - Painted Size- 4.8X 4.8 m with projection. 363 The concrete shall be placed and screeded to the finished grade, and floated to a uniform surface by using standard finishing techniques. The approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in two or more shakes, floated after each shake and trowelled only after the final floating. The approved release agent @ 0.113 kg/sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethane stamp moulds of approved design and in required sizes to achieve final stamped pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size & weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while concrete is in plastic stage of setting. 364 After stamping, the curing shall be done as per manufactures specifications. After initial curing the imprinted joints shall be grouted using cement slurrymixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/sqm.on finished surface. 365 The construction joints shall be provided by groove cutting of size 4mm x 20mm in panel size 3m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing and laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying Polyurethane resin based top protective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (Cost of concrete for flooring is not included in this item which shall be paid separately.) 366 P/Laying of stemped pathway including complete work. 367 P/Laying of Pebble Stonepathway including complete work. 368 Providing & fixing White/Colored River (Stone) Pebbles size of 1 to 2 dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. 369 P/Laying ofStonepathway (cutting Only.) 370 P/Laying of interlocking work including complete work. 371 KIDS PLAY- 372 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 373 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 374 Supplying and stacking at site. 375 Red bajri 376 Providing and fixing at site factory manufactured ready to install at site various swings for children play areaSPRIAL SLIDE - 1.5 m long 377 Providing and fixing at site factory manufactured ready to install at site various swings for children play areaSEE-SAW 378 BORING PUMP. 379 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre below ground level. Rocky strata including Boulders. 380 300 mm dia 381 350 mm dia 382 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 383 300 mm dia 384 350 mm dia 385 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 386 100 mm nominal size dia 387 150 mm nominal size dia 388 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 389 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 390 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 391 150 mm Dia 392 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 393 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).150 mm Dia 394 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints completeas per direction of Engineer in Charge. 395 50 mm nominal size dia 396 Electric logging of bore hole 397 Supply and Installation of 2.0 HP Submersible pump set complete 398 TOURIST FACILITY. 399 Providing & fixing ofred Sandstone/MS bench with Ornamentetion on armrest (size 1050mm length and 450mm and height 450 mm) including foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge. 400 Providing & fixing of SS Dustbin size 487 x 399 x 1138 fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge. 401 Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size 402 Signage-A 403 Signage-C 404 Specification of WAE-Drinking Water(Receiving, storing, handling, shifting, installation, testing & commissioning ofWAE. AENON.45.CHA Pou Water Station C.A, RO Processing Capacity 25LPH, size: 466X580X1445, Watt; 220v/50Hz, Cooling 480w, Hot 450W, net weight 110kg, in material SS 304, with 3 tap: Cold 20 Ltr,Ambient-25Ltr including all accessories complete in all respect etc. (Make - Voltas or Equivalent)) 405 G.S.T. Extra as per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
9.
Housing Urban and Rular Development #9443614 Technical Bid
tender for Tourism Development Work Of Amriteshwar Nath Shiv Mandir At Payagpur, Distt.-Bahraich, Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. Filling of earth in plinth in 20cm layer including leveling, dressing and watering and also including of supply of earth including carted loading & unloading as per direction of Engineer lincharge.. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources 3 graded stone aggregate 20 mm nominal size derived from natural sources) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement: 4 sand) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately): Red sand stone - Exposed face machine cut and table rubbed with rough backing. 50 mm thick T.M.T.-FE-500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & over lapping & hooks. Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement: 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement: 2 coarse sand), including making the necessary chases. Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement: 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone Supply fabrication transporting, hoisting and fixing in position good quality of 70mm Red sandstone in various elements for all levels, stone shall be free from cracks, lines stains and even in shade for each element The The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of ie carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work Shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects Supply fabrication & fixiing,in position ornamental Jharokha of cement concrete of size 500 mm x 700 mm & 200 mm wide. Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (1 cement: 3 coarse sand) cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources 3 graded stone aggregate 20 mm nominal size derived from natural sources). Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand, Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand 4 graded stone aggregate 12.5 mm nominal size). Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in sub structure below plinth level in all shapes and size in:1:6 (1 cement: 6 sand) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 150 in super structure above plinth level Jup to floor v level in all shapes and size in:1:6 (1 cement: 6 sand) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in- charge. 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a PVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 10.1 mm) wall thickness. The lock rail made up of H section, a PVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. U cleats. The shutter frame filled with a PVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers. complete, aa Monitoring all complete as per approved drawing & direction of E Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever (required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm, sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm). Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings wooden frames with rawl plugs screws etc. 15 mm cement plaster of mix: 1: 4 (1 cement: 4 coarse sand) 12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement: 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. Red sand stone Cement concrete flooring 1:2:4 (1 cement 2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). Providing and laying Vitrified floor tiles Kajariya KERRO Brand Jor Equivailent brand of super quality in different size (thickness specified by manufacture) with water absorption less than 10.80% and confirming to IS 15622 of approved make in all colors & shade laid on 20mm thick cement mortar 1:3 (1 cement 3 coarse sand) including grouting the joint with white cement and matching pigments etc complete (Size of tiles 600x600mm) [Skirting] 25mm Thick Kota Stone Slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includig rubbing and polishing complete with base of cement morter. 25mm Thick Kota Stone Slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includig rubbing and polishing complete with base of cement morter. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water tinnable priming coat with cement primer Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 Itr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).. Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Painting Steel work with Deluxe Multi Surface Paint to give an leven shade. Two or more coat applied @ 0.90 tr/10 sqm over Jan under coat of primer applied @ 0.80 Itr/10 sqm of approved brand and manufacture Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in- charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement:5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (C) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 120 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, windowsills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm (Granite of any shade) Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) Red sand stone exposed face fine dressed with rough backing. 50 mm thick Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require a) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tappillar tap. Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Providing and fixing rubbed stone slab table, edges rounded and polished, 75 cm high 50 cm deep and 18mm thick, fixed in Jurinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite stone of approved shade roviding and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge 15 mm nominal bore Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in- charge Providing and fixing CP BrassToilet Paper Holder of approved quality & make and as per the direction of Engineer-in-charge Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. Providing and fixing rubbed stone slab table, edges rounded and polished, 75 cm high 50 cm deep and 18mm thick, fixed in Jurinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite stone of approved shade roviding and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge 15 mm nominal bore Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in- charge Providing and fixing CP BrassToilet Paper Holder of approved quality & make and as per the direction of Engineer-in-charge Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. Providing & fixing baby Stainless Steel Baby Diaper cahnging station material unit dimensions depth (closed) VW-905 mm x H- 502 mm extension (open) 104 mm, 495 mm. Maximum load 25 Kgs Stainless steel #304 stain finish complete with all accessories & fittings as per drawing, bybo design, W00008 set- weisis (Euronics/Cera/Jaquar/Kohler/Toto or equivalent) Supply & fixing of CP soap tray fixed to the wall with PVC rubber plug with CP barss screws Make - Hindware, Model- F840004 Supply & fixing of CP brass plated health faucet with double lock 1.5 m long flexible hose with mounting bracket Make - Hindware, Model-F160002 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with C.J. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand 4 graded stone aggregate 20mm nominal size) i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design: With common burnt clay F.P.S.(non modular) bricks of class designation M-15 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40 mm nominal bore Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 50 to 80 mm nominal bore Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore Providing and fixing G.I. pipes complete with G.l. fittings and clamps, i/c cutting and making good the walls etc.(Internal Work) 32 mm dia nominal bore. (medium duty) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes CPVC 25 mm nominal outer dia Pipes Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion(i) Single socketed pipes. a) 110mm diameter Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement 4 coarse sand) and making good the wall etc. complete. a) 110mm Providing & fixing CPVC pipes complete with CPVC fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall a) 25mm dia nominal bore (medium duty) Providing & fixing CP brass short body of approved quality conforming to IS 8931 a) 15mm nominal bore Providing and fixing gun metal gate valve with wheel of approved quality. 25 mm nominal bore Providing and fixing gun metal gate valve with wheel of approved quality. 50 mm nominal bore Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete b) 25 mm nominal bore Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. a) Circular Tank Providing and fixing square mouth UPVC S.W.R. Gully trap grade A complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design.a) 150 x 110 mm. size P type With Sewer bricks conforming to IS: 4885 Constructing brick masonry manhole in cement mortar 1:4 (1) cement:4 coarse sand) RCC top slab with 1:2:4 mix (1 cement 2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement 4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement:2 coarse sand 4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80X50cms including Cl cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg) With FPS bricks of class designation 150 (i) For Sewer Line extra for depth of man hole size 90x80 cm Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement: 3 coarse sand: 6 gradded aggregate of nominal size 20mm) as per standard design with 20x20mm sq bars. Providing & fixing centrifugally (cast spun) 100mm dia vent pipes, Providing & fixing centrifugally (cast spun) 75mm dia vent pipes. Providing lead caulked joints to sand cost iron/ cetrifugally cast (squn) irons pipes & fitting of dia. 100 mm Providing lead caulked joints to sand cost iron/ cetrifugally cast (squn) irons pipes & fitting of dia. 75 mm Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement 2 coarse sand 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc.: For 100 mm dia pipe For 75 mm dia pipe Providing & fixing Cost iron coller: 100 mm dia Providing & fixing Cost iron coller: 75 mm dia Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet 75 mm outlet Providing and fixing plaincast iron ss sanitary bend; 100 mm Providing and fixing plaincast iron ss sanitary bend; 75 mm Providing and fixing centrifugaly cast iron single eual plai junction of reuired degree: 100x100x100 mm Providing and fixing centrifugaly cast iron single eual plai junction of reuired degree: 75x75x75 mm Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round S.VV. pipes including bed concrete as per standard design: 110/75 mm dia 150 mm dia Providing and fixing G.l. pipes complete with G.l. fittings & clamps including cutting & making good the wall etc. internal work exposed on wall 25 mm dia nominal bore Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality 25 mm nominal dia bore Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil 80 mm dia but not exceeding 300 mm dia. Providing, laying and jointing glazed stoneware pipes class SP- 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete 100 mm dia. Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete: 150 mm dia. R.C.C. pipe Providing & fixing gun metal non return valve of approved quality (screwed End) 50 mm nominal bore vertical Providing & Fixing G.I. pipes complete with G.I. Fittings including trenching & refilling etc. 25 mm nominal bore Providing & Fixing G.I. pipes complete with G.I. Fittings including trenching & refilling etc.32 mm nominal bore Providing & Fixing sand of grading zone V or coaser grade alround the G.I. pipe in external work 25 mm dia. Providing & Fixing sand of grading zone V or coaser grade alround the G.I. pipe in external work 50 mm dia.. Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Providing & fixing ridges and hips in non-asbestos fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc.complete. Corrugated serrated adjustable ridges. Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer- in-charge) 0.50 mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever reuired. Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m² Providing and fixing decorative cast iron corner bracket of size 300x300 having weight not less than 9.2 Kg.including the cost of machine moulding or any other suitable medium as reuired with respect to the drawing received from Architect in charge. Providing and fixing of sky light polycorbonate sheet 3.0 mm thick sheet, colour Transparent Transparency 80% features water proof surface treatment film coated (size, shape and pitch of corrugation as approved by the Architect-in-charge) size and shape whereever reuired. Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately): Red sand stone exposed face fine dressed with rough backing. 70 mm thick Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. In all kind of soil. From 0.00 to 1.50 Mt. 11.50 to 3.00 Mt. Fe 500 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fasts, tie, rods, grating etc. ( when not included in an over all rates) wrought to required form, including supply of steel bolts, nuts and wastage etc and their fixing required for proper completion of the work. 12 mm cement plaster of mix: 1: 4 (1 cement: 4 coarse sand) Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level Rocky strata including Boulders.350 mm dia Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia Gravel packing in tubewell construction in accordance with IS: 14097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. Development of tube well in accordance with IS: 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:150 mm dia Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part 1), including necessary bolts & nuts of required size complete.150 mm dia Providing and fixing Bail plug/Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part 1).150 mm dia Providing and fixing G.I. pipes complete with G.l. fittings including trenching and refilling etc. 50 mm dia nominal bore Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank. Providing & fixing 75mm dia vent pipes. Providing & fixing of 75mm dia cast iron terminal guard. Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 560mm internal diameter Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.VV. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 150 Electric logging of bore hole Supply and Installation of 1.5 HP Submersible pump set complete Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. Supply and fixing of 80 mm thick Precast cement concerete and Fly Ash Zig Zag-Shape rubber moulded Interlocking paver blocks ISI mark confirming to IS 15658-2006 with top layer of minimum 5 mm thickness of O.P.Cement smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro-compression mechanism. The compressive strength of concrete paver block shall not be less than 30 Mpa and weigt 4.5 kg per including cost of material, with a blanket layer of 5.00 cm. thick local sand including labour, T & P etc required for proper completion of the work as directed by Engineer-in- charge. 40 mm thick rubbed stone flooring over 20 mm (anerage) thick base of cement mortar 1:5 (1 cement: 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement: 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone Providing & fixing of red Sandstone/MS bench with Ornainentetion on armrest (size 1050mm length and 450mm and height 450 mm) induding oundation & support with all necessary T&P etc all complete as per design of direction in engineer/Architect in charge. Providing & fixing of SS Dustbin size 487 x 399 x 1138 fixing on la foundation with base plate and wrapped with red andstone from all sides of 75mm with all complete as per design of direction in engineer/Architect in charge. Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and iBustration at desired locations with letters (in english, hindi and Braille)- ehed, through cut, infilled or painted, also including the ost of design, fabrication and onsite installation with an the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Font with min. 36 size Signage-A Informative Sinage of Sandstone/ Marble of Size (1200 x 2100) MM visibility from both side Signage-C Informative Sinage of Sandstone/ Marble of Size (900 x 2400) MM visibility from both side Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). Supplying and stacking of good earth at site including royalty but including carriage 1km (earth measusred in stacks will be reduced by 20% for payment) Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment): Screened through sieve of I.S. designation 16 mm Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/or good earth to be paid separately). Rough dressing the trenched ground including breaking the clods. Fine dressing the ground Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). With grass Turf. Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly, as per direction of officer in charge (Selection No. 1) Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20%: 1 part of stacked volume of manure after reduction by 18%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately): Holes 90 cm dia, and 90 cm deep Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 18%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable materials as per direction of officer in charge (excluding cost of plant & water) Providing and stacking of Acacia auriculiformis of ht. 150-165 cm in bag size of 25 cm as per direction of the officer-in- charge. Providing and stacking of Adansonia digitata (kalp vriksha) of ht. 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. Providing and stacking of Bombax ceiba of ht. 150-165 cm in poly bag size of 25 cm as per direction of the officer-in-charge. Providing and stacking of Bottle palm of ht. 150-165 cm bottom girth 20-25 cm well developed in big in poly bag size of 25 cm Jas per direction of the officer-in-charge. Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big in HDPE bags as per direction of the officer-in-charge. Providing and stacking of Azadirachta indica (Neem) of ht. 120- 130 cm in big in poly bags of size 25 cm as per direction of the officer-in-charge. Providing and stacking of Tulsi of ht. 30 cm with multi branches in big in poly bags of size 20 cm as per direction of the officer- in-charge. Providing and stacking of Phyllanthus (Amla) of ht. 150-165 cm in big in HDPE bags as per direction of the officer-in- charge. Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in- charge. Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer Gl pipe of 16 swg and inner Gl pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.l. strip, upto switch board (from apron to switch board, the cost of G.l. strip will be extra) along with 30 cm square C.l. frame with hinged cover & masonry housing Make: As approved in U.P.P.W.D., & C.P.R.I. Certified Supply and laying of 25mm x 3mm G.l. strip from earth electrode directly in the ground as required complete in all respect. Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sq. mm 4 core 25 sq. mm 3-1/2 core 170 sq. mm 3-1/2 core Supplying and laying of following size owe HOPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming tolS 14930, Part II complete with fitting and cutting, Jointing etc. Jn the existing trench complete as required. 63 mm dla (OD-63 mm & D-51 mm nominal) Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die- cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 Fixture shall be suitable to operate at an ambient temperature range of 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.30V Supply Installation, Testing and Commissioning of ongrid Solar Photo voltaic Power Plant conforming to MNRE specifications as amended, consistingofMono/PolyCrystallinesiliconsolarcells,net meteringfacility,necessaryprotections, earthing, mounted on Aluminium/Gl structure of suitable strength with following componentscompleteasrequired: a) Solar PhotovoltaicModuleofca pacity330VVporabove, manufacturedinIndia, conformingtolS1428 БЛЕС61215, ISMEC61730-Part-1, ISMEC61730-Part- 2.SolarPhotovoltaicModuleconversionefficiencyshallnotbelessth an16.5%.PVmodules usedinsolarpowerplants/systemsmustbewarrantedfortheiroutp of 2.5Hz,output voltagesuitabletogenerateAC utpeakwattcapacity, whichshouldnotbelessthan90%attheendof 10yearsand80% atthe end b)PowerConditioning Unit (PCU)of350 800VDCInputvoltagerangeand400V threephase, 4wire, 50Hz+/- Powerwithefficiencynotlessthan97%,totalharmonicdistortionles sthan3% suitableforambienttemperaturefrom0to50degreeC.TheP CUshalladjustthe voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) FixingofArray junctionbox&Main junctionboxwith IP65protectionand terminationarrangement for incomingandoutgoingcablealongwithglands, lugs and other accessories etc. as required, e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kVgrade armouredpower and control cables between solarmodules, mainpower cable togrid supplyPCUunit alongwith supplying&fixingofnecessarychannel/conduit lugsandotheraccessoriesetc.as required. 25 years. AC, Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die- cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 Fixture shall be suitable to operate at an ambient temperature range of 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 40VV Supply and Fixing of Spike Light for trees 12 watt Warm White. 31386 12VV Anthracite COB Garden Spike 30 (make (Philips/Panasonic/Havells or Eauivalent)) Supply and fixing of steplignt robus T DESIGN IP 67/1K 10 easy to mount with suitable mounting box BVVG 50 LED 50 /N/WPSU 220-240 V IP67 7043 (Philips/Havells/Panasonic or equivalet) Supply and fixing of LED Bollard robustly designed IP65/KL-7062 8112W LED WWW.NW.C/W, Clear Polycarbonate 0100 X 900mm M2 (Make Twinkle 1Qlite/Havells/Neri/Juvaas/Olient/Thor orequivalet) Lite- Receiving, storing, handling, shifting, installation, testing & commissioning of WAE. AENON.45.CHA For Wire Station C.A, RO Processing Capacity 25LPH, size: 466X580X1445, Watt; 220v/50Hz, Cooling 480w, Hot 450W, net weight 110kg, in material SS 304, with 3 tap: Cold 20 Ltr, Ambient-25Ltr including all accessories complete in all respect etc.(Make Voltas or Equivalent) Wiring point for light with 1.5 sq. mm.FR PVC insulated multistrand single core copper conductor cable in PVC conduit pipe with 1.5 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete Modular type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash Wiring point for Exhaust Fan with 1.5 sq. mm. F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete Modular type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash Wiring point for plug with 1.5 sq. mm. F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduit partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete Modular type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash Supply and fixing of recess/ Surface/Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respect. CAT-AAA Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer Gl pipe of 16 swg and inner Gl pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.1, strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. Supply and fixing of recess/Surface/Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and Idriver set complete in all respect. CAT-AAA Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (b) 10sq. mm 2 core Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect, The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (b) 10sq. mm 2 core Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. (c) 10 sq. mm Supply and fixing of Two number 8 SVG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. S&F of 6 Amp to 32 Amp. SPMCB (10.KA) C Curve CAT-A S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve 32. Amp. DP MCB (10KA) CAT-A Supply and fixing of crimping, solderless, copper tin electroplated lugs of Dowells/Ismail make suitable for 1.5 sq.mm to 2.5 sq.mm cables, including tapping with insulating tape, complete in all respect. S&F single pole MCB blanking plate CAT-A S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. CAT- A Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. Supply and fixing of 16 gauge M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. Supply and fixing of single phase multifunctional electronic energy meter 10 to 60 Amp. capacity fitted in integral box on wall complete in all respect. Supply of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level: (4550) dB, Power consumption: 45 W, Rated voltage: 230 V, Rated frequency: 50 Hz, Motor type: Normal Speed. Complete in all respect. 230 mm sweep Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SVVG copper earth continuity wire, GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash Wiring point for two ways light with 1.5 sq. mm. F.R. PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SVVG copper earth continuity wire, GP Box and two number two way piano type switches & ceiling rose / angle / batten holder on 3 mm thick phanolic laminated backelite sheet etc., complete in all respect, as directed, including matching colour wash. Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SVWG copper earth continuity wire, GP Box, piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SVVG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. Wiring point for exhaust fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SVVG copper earth continuity wire, GP Box, 15A piano type switch & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect including matching colour wash. Wiring point for light in 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable (drawn through existing concealed steel conduit) and 5 Amp.flush type switch & ceiling rose/angle/batten holder fixed with 3mm thick phenolic laminated backalite sheet with brass machine screws and cup washers mounted over existing M.S. switch board box/junction box with supply of all material, labour & T&P etc. required for proper completion of the work as directed at site by the Engineer in charge.but for plug point with 5 Amp flush type switch and 3 pin socket and earth continuity wire of 1.5 sq.mm. FRLSH PVC insulated multi strand copper conductor cable. Add for light / fan points with modular type switch in place of piano type switch. Add for 2 way light point with modular switches in place of piano type switches. Add for plug point with modular switch & socket in place of piano type switch & socket. Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch. Supply and wiring of submain with two number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 14 SVVG copper earth continuity wire including matching colour wash etc. complete in all respect. Supply and wiring of submain with two number 6 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core aluminium conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 14 SVVG copper earth continuity wire including matching colour wash etc. complete in all respect. Supply and wiring of 4 number 6 sq.mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 25 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 14 SVVG copper earth continuity wire including matching colour wash etc, complete in all respect. Supply and wiring of 4 number 10 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 10 SWG Icopper earth continuity wire including matchina colour wash etc, complete in all respect, Supply and fixing of batten / angle holder complete in all respect. Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAA Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. CAT-AAA Supply of ceiling fan with fan motar of A.C. permanent insulation, capacitor rating conforming and IS: 374/79 and also comply with IS;1709//1984 with latest amendment. The rated voltage 220/240 volts, 50 Hz, 1-ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with doubble ball bearing system. BEE 5 star rated -1200 mm sweep Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (j) 25 sq. mm 3-1/2 core Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. (e) 25 sq. mm Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with. crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.J. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects, The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. Thea Monitoring System complete with accessories. d) FixingofArray IP65protectionand junctionbox&Main junctionboxwith terminationarrangement for incomingandoutgoingcablealongwithglands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kVgrade armouredpower and control cables between solarmodules,mainpower cable S&F of 63 Amp. 4 pole MCB(10 KA) C Curve CAT-A S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT-A S & F surface/Flush mounting 6ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge CAT-A Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. Erection and testing of ceiling fan and regulator for room height upto 3.5 metres including supply of 3mm thick G.I.Pipe19mm dia. Duly painted, complete in all respect. Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. Supply and fixing of electronic fan regulator(Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.. Supply and fixing following modular base & cover plate on the existing modular /GP boxes etc. as required. 1 or 2 Module Supply and fixing following modular base & cover plate on the existing modular /GP boxes etc. as required. 3 Module Supply and fixing following modular base & cover plate on the existing modular /GP boxes etc. as required. 4 Module Supply and fixing following modular base & cover plate on the existing modular /GP boxes etc. as required. 6 Module Supply and fixing following modular base & cover plate on the existing modular /GP boxes etc. as required. 8 Module Supply and fixing following modular base & cover plate on the existing modular /GP boxes etc. as required. 12 Module Supply & Fixing of 12 Watt LED Bulb -B22/E27 (Colour Temp- 6500K/ Lumenes -900 Im) cool day light/ input volts (Ac 90 V- 260V, 3-star rating, suitable for batten/angle holder including making Connection in all respect. Supply & Fixing of 400 mm sweep wall mounnted (Light Duty fan complete with Plastic Blade & Pull Cord (Adjustable upward & downwword tilt mechanism/motorcapcitor etc.) Oscillation degree-90, Power Consumption, 60VV, Rated voltage: 230 V Rated Freuency:50 Hz, Speed 1350 RPM complete in all respect..
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
10.
Housing Urban and Rular Development #9443211 Technical Bid
Tender For Eco Tourism Development Work Of Rampur Sohrauna Distt Kushinagar, 1 Ghat Development 2 Dismantling old plaster or skirting raking out joints and cleaning the surface of plaster including disposal of rubbish to the dumping ground within 50 meters lead. 3 Providing and fixing white vitreous china water closet squatting pan (Indian type) along with S or p TRAP INCLUDING dismantling of old WC seat and S or P trap atsite complete with all operations including all necessary materials, labour and disposal of dismantled material including all necessary malba, all complete as per the direction of Engineer in charge. Orrisa pattern WC pan of size 580 x 440 mm 4 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) 5 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 6 Earthwork in excavation mechanical means / manual means over areas exceeding 30 cm in depth 1.5 m in width as well 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m as directed by engineer in chargeall kinds of soil 7 Earthwork in excavation mechanical means / manual means in foundations trenches or drains not exceeding 1.5 m in width or depth or 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m as directed by engineer in chargeall kinds of soil 8 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solutionand the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 20.3.1 300 mm dia piles 10 Extra for providing additional bulb in under reamed piles. 20.4.1 300 mm dia piles 11 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 12 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 13 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 14 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 15 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like 16 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracingscovered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineer-in-Charge.(Note :- One time payment shall be made for providing barricadingfrom start of work till completion of work i/c shifting. The barricadingprovided shall remain to be the property of the contractor on completionof the work). 17 Banking exacavated earth by mechancial/ manual means in layers not exceeding 20 cm in depth breaking clods watering rolling each layer with 1/2 tonne roller or wooden or steel rammers and rolling every 3rd and top most layer with power roller of min 8 tonnes and dressing up in embankments for roads flood banks marginal and guide banks lead up to 50 mm and for all life - all kinds or soil. deduct for not rolling with power roller of minimum 8 tonne 18 Supplying old/used empty Cement bags including all texes. Filling empty cement bags with locaearth/RBM/silt, hand sewing with suja & sutli and placing in position within 60 M placing. (As per S.O.R. Chept XIX/7b ) 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 20 52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardenerm mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturersspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 21 Extra for making chequers of approved pattern on cement concrete floors, steps, landings, pavements 22 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube 23 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 24 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 7.20.1 Red sand stoneExtra for stone work ashlar sunk or moulded or sunk and moulded orcarved in :7.21.1 Triangular or Square or rectangular pillars 25 Provinding and fixing S.S CHAIN 26 Vertical load testing of piles in accordance with IS 2911 (Part IV) inlcuding installation of loading platform by kentledge/ anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification and the direction of the engineer in charge 27 Single pile upto 50 tonne safe capacity 28 Initial test (test load 2.5 times the safe capacity) 29 Routine test (test load 1.5 times the safe capacity) 30 Pavilions 31 Earthwork in excavation mechanical means / manual means in foundations trenches or drains not exceeding 1.5 m in width or depth or 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m as directed by engineer in chargeall kinds of soil 32 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) 33 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 34 BRICK WORK 35 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 36 REINFORCEMENT CEMENT CONCRETE 37 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. concrete of m25 grade withminimum cement content of 330 kg /cum 38 All works above plinth level upto floor V level concrete of m25 grade withminimum cementcontent of 330 kg /cum 39 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. thermo-Mechanically Treasted bars of grade Fe-500D or more. 40 SHUTTERING 41 Centering and shuttering including strutting, propping etc. and removal of form for 42 Foundations, footings, bases of columns, etc. for mass concrete 43 Columns, Pillars, Piers, Abutments, Posts and Struts 44 Lintels, beams, plinth beams, girders, bressumers and cantilevers 45 Suspended floors, roofs, landings, balconies and access platform 46 STONE WORK 47 Providing and fixing red sand stone brackets 55x22.5x45 cm sunk andmoulded including providing and fixing with 4 Nos gun metal cramp25x6 mm 30 cm long 48 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :8.14.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing.8.14.2.4 40 mm thick 49 30 mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement : 4 coarse sand), including finishing complete. 50 TERRACING 51 [Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved Ly Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approve by Engineer-in­ charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in­ charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surfacewith trowel with neat cement slurry and making pattern of 300x300 mm square 3 mmdeep. 52 (e)The whole terrace so finished shall be flooded withwater for a minimum period of two weeks for curingand for final test.All above operations to be done inorder and as directed and specified by the Engineer­in-Charge : With average thickness of 120 mm andminimum thickness at khurra as 65mm. With average thickness of 120 mm and minimumthickness at khurra as 65 mm. 53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 54 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 55 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 56 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 57 Electrical Works Pavilion 58 Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting, complete with modular typeswitch & ceiling rose/ angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash 59 Wiring point for plug with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable as earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 60 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 61 Addition for light / fan points with modular type switchin place of piono type switch. 62 Addition for plugpointswith modular switch& socket in place of piano type switch & socket. 63 Supply and wiring of submain with one number 1.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit in 20mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. 64 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor. 65 cable as earth contunity wire etc. complete in all respects. 66 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor. 67 cable as earth contunity wire etc. complete in all respects. 68 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . 69 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES 70 Supply & fixing of recess mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 71 SUBHEAD III-DISTIBUTION BOARD 72 Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects. 73 6 Way TPN (CAT A) 74 4 Way SPN (CAT A) 75 Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. (CAT A) 76 Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 77 63 Amp. 4 Pole MCB (CAT B) 78 Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 79 Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 80 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. 81 SUBHEAD IV-CABLES 82 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size. 83 16 sqmm4 core 84 25 sqmm3.5 core 85 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction 86 16 sqmm4 core 87 25 sqmm3.5 core 88 Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 89 16 Sq.mm 90 25 Sq.mm 91 Change Rooms (Male & Female changing rooms (2) 92 Earthwork in excavation mechanical means / manual means in foundations trenches or drains not exceeding 1.5 m in width or depth or 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m as directed by engineer in chargeall kinds of soil 93 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) 94 BRICK WORK 95 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 above plinth level superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 96 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 97 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) 98 REINFORCEMENT CEMENT CONCRETE 99 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. concrete of m25 grade withminimum cement content of 330 kg /cum 100 All works above plinth level upto floor V level concrete of m25 grade withminimum cementcontent of 330 kg /cum 101 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. thermo-Mechanically Treasted bars of grade Fe-500D or more. 102 SHUTTERING 103 Centering and shuttering including strutting, propping etc. and removal of form for 104 Lintels, beams, plinth beams, girders, bressumers and cantilevers 105 Lintels, beams, plinth beams, girders, bressumers and cantilevers 106 Suspended floors, roofs, landings, balconies and access platform 107 STONE WORK 108 Providing and fixing red sand stone brackets 55x22.5x45 cm sunk and moulded including providing and fixing with 4 Nos gun metal cramp 25x6 mm 30 cm long 109 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :8.14.2 Red sand stone - Exposed face machine cut and table rubbed with rough backing.8.14.2.4 40 mm thick 110 30 mm red sand stone sun-shade (chisel-dressed) supported on red sand stone brackets, fixed in walls with cement mortar 1:4 (1 cement : 4 coarse sand), including finishing complete. 111 TERRACING 112 [Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved Ly Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approve by Engineer-in­ charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in­ charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surfacewith trowel with neat cement slurry and making pattern of 300x300 mm square 3 mmdeep. 113 (e)The whole terrace so finished shall be flooded withwater for a minimum period of two weeks for curingand for final test.All above operations to be done inorder and as directed and specified by the Engineer­in-Charge : With average thickness of 120 mm andminimum thickness at khurra as 65mm. With average thickness of 120 mm and minimumthickness at khurra as 65 mm. 114 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 115 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 116 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 117 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 118 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 119 DOOR VENTILATOR 120 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. 121 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 122 Providing and fixing stainlees steel fancy handles with approved make ISI mark as approved 200 mm 123 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 124 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm 125 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 126 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 127 Hold fast for chaukhats of doors/windows. 128 FINISHING 129 Pointing on brick work or brick flooring with cement mortar 1:3 flushed/ rules/ struct or weathered pointing 130 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 131 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 132 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 133 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 134 FLOORING 135 Providing and laying recitified glazed ceramic floor tiles of size 300 by 300 ,, of 1 st quality conforming to IS 15622 of approved make in all colours shades in colurs while gret ivory fume red brown laid n 20 mm thick cement mortar 1:4 jointing with grey cement slurry 3.3 kg . sqm including pointing the joints with white cemet and matching pigments et. complete 136 engraving letters in hard stone 137 Providing and fixing factory made single extruded WPC solid decorative type flush door shutter of required size comprising of virgin polmer 35 mm thick 138 Ventilator casement window single panel with or without fixed panel 139 Electrical works - changing room (Male & Female changing rooms (2) 140 Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting, complete with modular typeswitch & ceiling rose/ angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash 141 Wiring point for plug with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable as earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 142 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 143 Addition for light / fan points with modular type switchin place of piono type switch. 144 Addition for plugpointswith modular switch& socket in place of piano type switch & socket. 145 Supply and wiring of submain with one number 1.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit in 20mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. 146 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor. 147 cable as earth contunity wire etc. complete in all respects. 148 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor. 149 cable as earth contunity wire etc. complete in all respects. 150 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . 151 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES 152 Supply & fixing of recess mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 153 SUBHEAD III-DISTIBUTION BOARD 154 Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects. 155 6 Way TPN (CAT A) 156 4 Way SPN (CAT A) 157 Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. (CAT A) 158 Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 159 63 Amp. 4 Pole MCB (CAT B) 160 Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 161 Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 162 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. 163 SUBHEAD IV-CABLES 164 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size. 165 16 sqmm4 core 166 25 sqmm3.5 core 167 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 168 16 sqmm4 core 169 25 sqmm3.5 core 170 Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 171 16 Sq.mm 172 25 Sq.mm 173 Bird Watching Tower (Civil Works) 174 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 175 Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. 176 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 177 Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 178 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 179 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) 180 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 181 RCC WORK 182 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 183 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 184 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 185 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 186 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 187 B/W WORK 188 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 189 FLOORING 190 52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardenerm mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturersspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 191 Extra for making chequers of approved pattern on cement concrete floors, steps, landings, pavements 192 MS WORK 193 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube 194 FINISHING 195 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 196 Shuttering 197 Centering and shuttering including strutting, propping etc. and removal of form for 198 Columns, Pillars, Piers, Abutments, Posts and Struts 199 Lintels, beams, plinth beams, girders, bressumers and cantilevers 200 Suspended floors, roofs, landings, balconies and access platform 201 Lintels, beams, plinth beams, girders, bressumers and cantilevers 202 Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm ofcement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab adjoining wall upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining heights upto 300mm height including rounding of junctions of walls and slabs. (c) After two days of propoer curing applying a second of cement slurry using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed water proofing compound conforming to IS 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test . All above operations to be done in order and as directed and specified by the Engineer-in-charge with average thickness of 120 mm and minimum thickness at khurra as 86mm 203 Rough cast plaster upto 10m height above ground level with a mixture of a sand and graval of crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two laper under 12 mm cement plaster ( 12 cement :3fine sand ) mixed with 10% finelt grounded hydrated lime by volume of cement ordinary cement finhish using ordinary cement 204 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 205 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 206 Providing and laying pressed clay tiles (as per approved pattern 20 mm norminal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2 % integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 and finished neat complete 207 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 208 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 209 [Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved Ly Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approve by Engineer-in­ charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in­ charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surfacewith trowel with neat cement slurry and making pattern of 300x300 mm square 3 mmdeep. 210 (e)The whole terrace so finished shall be flooded withwater for a minimum period of two weeks for curingand for final test.All above operations to be done inorder and as directed and specified by the Engineer­in-Charge : With average thickness of 120 mm andminimum thickness at khurra as 65mm. With average thickness of 120 mm and minimumthickness at khurra as 65 mm. 211 Bird Watching Tower (Electrical Works) 212 Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting, complete with modular typeswitch & ceiling rose/ angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash 213 Wiring point for plug with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable as earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 214 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 215 Addition for light / fan points with modular type switchin place of piono type switch. 216 Addition for plugpointswith modular switch& socket in place of piano type switch & socket. 217 Supply and wiring of submain with one number 1.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit in 20mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. 218 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor. 219 cable as earth contunity wire etc. complete in all respects. 220 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor. 221 cable as earth contunity wire etc. complete in all respects. 222 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . 223 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 224 Supply & fixing of recess mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 225 Supply & fixing of recess mounting round 15 to 18 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 226 SUBHEAD III-DISTIBUTION BOARD 227 Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects. 228 6 Way TPN (CAT A) 229 4 Way SPN (CAT A) 230 Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. (CAT A) 231 Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 232 63 Amp. 4 Pole MCB (CAT B) 233 Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 234 Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 235 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. 236 SUBHEAD IV-CABLES 237 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size. 238 16 sqmm4 core 239 25 sqmm3.5 core 240 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 241 16 sqmm4 core 242 25 sqmm3.5 core 243 Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 244 16 Sq.mm 245 25 Sq.mm 246 Site Development Works 247 Boundary Wall (160 Mtr 248 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including dressing of sides and ramming of bottoms for all lift including getting out excavated soil and disposal of surplus excavated soil as directed wihin a lead of 50 m All kinds of soil 249 Excavating, supplying, stacking and filling of loacal earth (including royalty) by mechanical means tranport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in foundations trenches plinth sides of foundations etc complete for all lift 250 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 251 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 252 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved branf and manufacture 253 Applying primimg coats with ready mixed red oxide zince chromate primer of approved brand and manufacture on steel galvanised iron / steel work 254 RCC: standard post/ struts/ rails/ pales of mix 1:1.5:3 with wooden plugs or 6 mm bar nibs wherever required as per direction of engineer in charge (cost of earth works in excavation, concrete works in foundation to be paid separatelt). 255 Welded steel fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer ( priming and painting to be paid seaparetly 256 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45 X 45 X 60 cm mix 1:5:10 every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete vlocks 70 X 45 X 50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with GI staples on wooden plugs or tied to 6 mm bar nibs with GI binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately). 257 Pathway (180 sqm) 258 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil 259 Excavating, supplying, stacking and filling of loacal earth (including royalty) by mechanical means tranport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in foundations trenches plinth sides of foundations etc complete for all lift 260 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 261 Supplying and filling in plinth with sand under floors including watering, ramming consolidation and dressing complete 262 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 263 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 264 Brick on edge flooring with bricks of class deignation 7.5 on a bed of 12 mm cement mortar including filling of joints with same mortar with common burnt clay non modular bricks 1:4 cement and coarse sand 265 Demolishing dry brick pitching in floors, drains etc. including stacking of servicable material and disposal of unservicable material within 50 meters lead 266 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) in cement mortar 267 Pointing on brick work or brick floorinG with cement mortar 1:3 flushed/ rules/ struct or weathered pointing 268 Horticulture Works 269 Clearing grass and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 270 Surface dressing of the ground including removing vegetation and including equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 mall kinds of soil 271 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same all kinds of soils 272 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 273 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 274 Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) 275 Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment). 276 Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately). In rows 5 cm apart in both directions 277 Complete maintenance of trees (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department and other T & P material/articles shall be provided by the contractor) and as per direction of officer in charge. Trees for 250 no/(up to 4 & up to 3 year Slow & Fast growing group) 278 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) 279 Shrub 280 Hedge 281 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : HOLES 45CM DEEP, 45 CM DIA 282 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 75- 90 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 283 Providing and stacking of Dianella variegated, with 3 to 4 variegated leaves in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. 284 Bamboo Buddha valley with fresh & healthy 3 to 4 suckers having 75 to 90 cm ht. plant in 25 cm size Earthen Pot/ Plastic Pot 285 Ficus benjamina (green) height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bag 286 Fishtail palm ht. 150-180 cm bottom girth 15-20 cm well developed in big poly bag size 25 cm 287 Providing and displaying of Areca Palm having ht. 1.20 m to 1.50 m with 5 to 6 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 288 Providing and displaying of Livistona palm having ht. 60 cm to 75 cm, well developed with 8 to 10 leaves, fresh & healthy foliage in 30 cm size of Earthen pot/Plastic pot. as per direction of the officer-in-charge. 289 Providing and stacking of Cassia laevigata of height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. 290 Providing and stacking of Dombeya mastersii of height 60-75 cm. with 4- 5 branches in bag of size 25 cm as per direction of the officer-in-charge. 291 Providing and stacking of Ficus reginald well branched, bushy of height 60- 75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 292 Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3- 4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge. 293 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. 294 Providing and stacking of Cestrum nocturnum (Raat ki Rani) of height 60- 75 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge. 295 Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge. 296 Topiary cutting/shapping of plant removing of cut materials, cleaning, hoeing of plants complete design hoeing of trees (Topiary) watering manure etc.(excluding the cost of material which shall be supplied by thedepartment) and as per direction of officer in charge. 297 Providing and fixing of Alphabet topiary frames in stainless frame approximate size 2 ft by 1.5 ft as approved by site engineer 298 External Electrification Solar Lights 299 Supply , installation , testing and commissiioning of 12-16 watt LED Solar Street Light System including 5 years comprehensive warranty with following items-P.V module :- only indigenous modules shall be used in the project S.P.V MODULE 75 Wp under STC. Battery :- lithium ferro Phspha Battary minimum 12.80 volt 40 ah capacity with mppt controllar. Light source :- Phllips/ havels/ lafit / lustere etc similar brand as approved by architect / site engineer make 12 watt white Light emitting Diode (w-led) with driver set luminaire dispersed beam , soothing to eyes with the use of proper optic and diffuser Mounting of light :- 65 mm dia mediumn class hot dipG>I> pipe designer pole 6.00 metre long pole height 5.00 metre above the ground level luminaire shall be atleast 4.60 metre above the ground level as approved by architect / engineer in charge photographs Name plate Warrenty :- 5 years comprehensive warranty 300 Sitouts & Seating 18 Planters 301 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 302 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources). 303 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 304 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 305 Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 306 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 307 Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. 308 Pointing on brick work or brick floorinf with cement mortar 1:3 flushed/ rules/ struct or weathered pointing 309 Signages & Place Making 310 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 311 Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. 312 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) 313 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 314 Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 315 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 316 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. concrete of m25 grade withminimum cement content of 330 kg /cum 317 All work up to plinth level 318 Brick on edge flooring with bricks of class deignation 7.5 on a bed of 12 mm cement mortar including filling of joints with same mortar with common burnt clay non modular bricks 1:4 cement and coarse sand 319 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 320 Providing & fixing of Theme based place making work which contain 8 nos Sculpture of various sizes ranging from 0.75 m to 1.75 mt - Theme based set on story of Manjhariya devi mata made with solid red sand stone fiber casting, water proof & all weather proof material with installation on site. (Mixture item - Raisin, katlist, Exilater, Fiber Mat, marbal dust etc.), Product is made in solid (product will not damage with sunlight), sculpture color will be as per architect approved. 321 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 322 Centering and shuttering including strutting, propping etc. and removal of form forEdges of slabs and breaks in floors and wallsUnder 20 cm wide 323 SIGNAGES 324 EARTHWORK 325 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 2.1.1 All kinds of soil 326 PCC WORK 327 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 328 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 329 Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 330 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 331 BRICKWORK 332 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 333 From ground level upto plinth level 334 Above plinth level upto floor V level 335 STEEL WORK 336 Providing 3mm thick MS sheet powder coated with primer coat as per design approved by engineer in chargerand bolted to masonry work all complete 337 Providing and fixing carbon galvanised (minimum coating 5 micron dash fasterner of 01 mm dia double threaded 6.8 grade (yeild strength 480 N/Mm2 counter sunk head comprsing 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame, concrete / masonry etc as per direction of engineer in charge. 10x 120 mm 338 FINISHING 339 Finishing with epoxy paint two or more coats at all locations prepared and applied as per manufacturers specifications including priming coat preparation of surface etc complete on steel work 340 Cost of CNC, on MS SHEETof any thickness required for precise carving wherever required of approved depth as per design approved from Arhcitect in charge including cost of designing, for overall mural including the cost of labour involved in day to day fabrication and processing of Artistic work 341 Tube Well 342 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil 300 mm dia 343 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 344 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineerin-charge. 345 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 346 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 347 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 348 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 349 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 350 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewellas per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 351 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 50 mm nominal bore 352 Providing and fixing Kirloskar 3.7 kiloWatt 5 LPS Three Phase-Submersible Pump Set 353 Site Drainage (200 Mtr) 354 CONSTRUCTION OFAPRON DRAIN (250X300MM) LENGTH OF DRAIN 200 METERS 355 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge 356 Entry Gateway 357 Earthwork in excavation mechanical means / manual means over areas exceeding 30 cm in depth 1.5 m in width as well 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m as directed by engineer in chargeall kinds of soil 358 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m 359 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources). 360 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 361 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 362 All work up to plinth level 363 All work above plinth level 364 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. thermo-Mechanically Treasted bars of grade Fe-500D or more. 365 SHUTTERING 366 Centering and shuttering including strutting, propping etc. and removal of form for 367 Foundations, footings, bases of columns, etc. for mass concrete 368 Columns, Pillars, Piers, Abutments, Posts and Struts 369 Lintels, beams, plinth beams, girders, bressumers and cantilevers 370 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. asrequired. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 371 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work 372 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) 373 Pointing on brick work or brick flooring with cement mortar 1:3 flushed/ rules/ struct or weathered pointing 374 Brick work with common burnt clay FPS non modular bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 375 Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) 376 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 377 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 378 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 7.20.1 Red sand stone Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 7.21.1 Triangular or Square or rectangular pillars 379 Providing and fixing of stainless steel letters luminated (alphabets) in matt finish grade 316 total 17 letters (20cm height) as per approved colour, font, design, and size including UP Tourism logo 380 Multi Purpose Hall (Civil) 381 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. All kinds of soil 382 Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge. 383 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 384 Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 385 PCC WORK 386 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 387 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 388 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 389 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 390 REINFORCEMENT CEMENT CONCRETE 391 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. concrete of m25 grade withminimum cement content of 330 kg /cum 392 All works above plinth level upto floor V level concrete of m25 grade withminimum cementcontent of 330 kg /cum 393 BRICKWORK 394 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 395 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 above plinth level superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 396 TERRACING (WATER PROOFING) 397 [Providing and laying integral cement base water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved Ly Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approve by Engineer-in­ charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in­ charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surfacewith trowel with neat cement slurry and making pattern of 300x300 mm square 3 mmdeep. 398 (e)The whole terrace so finished shall be flooded withwater for a minimum period of two weeks for curingand for final test.All above operations to be done inorder and as directed and specified by the Engineer­in-Charge : With average thickness of 120 mm andminimum thickness at khurra as 65mm. With average thickness of 120 mm and minimumthickness at khurra as 65 mm. 399 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 400 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 401 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 402 DOOR & WINDOWS 403 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 404 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.9.127.2 1.0 mm thick 405 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. 406 Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately. Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii)Sites with structure height more than 20m for all wind speeds 407 Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body. Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) (Height upto 1.8m) 408 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 409 Providing and fixing stainlees steel fancy handles with approved make ISI mark as approved 200 mm 410 Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. 411 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper 412 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm 413 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 414 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.5 mm thickness 415 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture withmatching wood beading 416 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. thermo-Mechanically Treasted bars of grade Fe-500D or more. 417 FINISHING 418 Pointing on brick work or brick floorinG with cement mortar 1:3 flushed/ rules/ struct or weathered pointing 419 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 420 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 421 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 422 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre 423 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 424 FLOORING 425 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green 11.0 FLOORING SUB HEAD : 11.0 FLOORING 235 SUB HEAD : 11.0 FLOORING 236 Code Description Unit Rate No. marble chips of sizes from 1 mm to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, including cement slurry etc. complete 426 Dark shade pigment with ordinary cement 427 SHUTTERING 428 Centering and shuttering including strutting, propping etc. and removal of form for 429 Foundations, footings, bases of columns, etc. for mass concrete 430 Columns, Pillars, Piers, Abutments, Posts and Struts 431 Lintels, beams, plinth beams, girders, bressumers and cantilevers 432 Lintels, beams, plinth beams, girders, bressumers and cantilevers 433 Suspended floors, roofs, landings, balconies and access platform 434 Suspended floors, roofs, landings, balconies and access platform 435 Terracotta jali 436 Installation charges for fixing of façade at all heights with extruded hollow clay/terracotta ventillated rain screen tiles 437 P/F Terracotta jali 438 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm 439 long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :2.45.4 Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer in-charge and as per manufacturers specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 440 Structural steel work riveted, welded, or boltedin built up sections, trusses, and framed work, including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer all complete 441 Providing and laying pressed clay tiles (as per approved pattern 20 mm norminal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2 % integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 and finished neat complete 442 Electrical Works 443 Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting, complete with modular typeswitch & ceiling rose/ angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash 444 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cableas earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 445 Wiring point for plug with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable as earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 446 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 447 Addition for light / fan points with modular type switchin place of piono type switch. 448 Addition for plugpointswith modular switch& socket in place of piano type switch & socket. 449 Supply and wiring of submain with one number 1.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit in 20mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. 450 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor. 451 cable as earth contunity wire etc. complete in all respects. 452 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor. 453 cable as earth contunity wire etc. complete in all respects. 454 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . 455 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 456 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. 457 Supply and fixing hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. 458 Supplyfixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. 459 Supply and Ceiling fan with fan motor of AC permanent insulation, capacitor rating conforming BEE 5 star rating and IS: 374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volt 50Hz, 1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball breaing system 460 BEE 5 star rated-1200 mm sweep 461 Supply & fixing of recess mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 462 Supply & fixing of recess mounting round 15 to 18 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 463 Provinding & fixing Aluminum LED Track Spot Light LED Panel recess mounting for armstrong / Pop / Zip Board cellings complete with separate electronic driver and high brightness SMD LEDs (3000,4000,6500K) 464 SUBHEAD III-DISTIBUTION BOARD 465 Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects. 466 6 Way TPN (CAT A) 467 4 Way SPN (CAT A) 468 Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. (CAT A) 469 Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 470 63 Amp. 4 Pole MCB (CAT B) 471 Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 472 Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 473 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. 474 SUBHEAD IV-CABLES 475 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size. 476 16 sqmm4 core 477 25 sqmm3.5 core 478 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction 479 16 sqmm4 core 480 25 sqmm3.5 core 481 Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 482 16 Sq.mm 483 25 Sq.mm 484 Drinking Water Kiosk 485 Civil Works 486 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil 487 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m 488 Supply and stacking of fly ash conforming to IRC- 58 at site. Including carriage, loading , unloading and stacking upto any lead 489 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 490 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 491 16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 492 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 493 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 494 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 495 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 496 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 497 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 498 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 499 All work up to plinth level 500 All work above plinth level 501 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 502 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 503 Surface dressing on new surface with paving bitumen of grade VG - 10 of approved quality using 2.25 kg of bitumen per sqm with 1.65 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete: 504 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 above plinth level superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 505 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand) 506 Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 507 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. 508 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. U cleat The shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thicknessof 20 mm and 1 mm (± 0.1 mm) wall thickness . The panelsfilled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturers specification anddirection of Engineer-in-charge. 509 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 9.73.3 100x125x27x5 mm 510 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. 511 providing 40x5 mm flat iron hold fats 400 mm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150mm 1:3:6 mix. 512 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. thermo-Mechanically Treasted bars of grade Fe-500D or more. 513 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) 514 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) 515 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green 11.0 FLOORING SUB HEAD : 11.0 FLOORING 235 SUB HEAD : 11.0 FLOORING 236 Code Description Unit Rate No. marble chips of sizes from 1 mm to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, including cement slurry etc. complete 516 Dark shade pigment with ordinary cement 517 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 518 Distempering (new work - Two coat or more coats ) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including water thinnable priming coatwith cement primer of approved brand & manufacture after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.(Ceiling) 519 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 520 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 521 Providing and fixing sliding bolts 522 Providing and fixing Tower bolts 523 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 524 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 525 Centering and shuttering including strutting, propping etc. and removal of form for 526 Foundations, footings, bases of columns, etc. for mass concrete 527 Columns, Pillars, Piers, Abutments, Posts and Struts 528 Lintels, beams, plinth beams, girders, bressumers and cantilevers 529 Lintels, beams, plinth beams, girders, bressumers and cantilevers 530 Suspended floors, roofs, landings, balconies and access platform 531 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels 8.2.2 Granite stone slab of colour black, Cherry/Ruby red 8.2.2.2 Area of slab over 0.50 sqm 532 Providing and laying pressed clay tiles (as per approved pattern 20 mm norminal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2 % integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 and finished neat complete 533 Pointing on brick work or brick floorinG with cement mortar 1:3 flushed/ rules/ struct or weathered pointing 534 P/F Terracotta jali 535 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 536 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 537 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 538 Electrical Works 539 Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting, complete with modular typeswitch & ceiling rose/ angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash 540 Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cableas earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. 541 Wiring point for plug with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable as earthwire drawn inside the conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with14 SWG copper earth continuity wire and piano type switch and socket etc., complete in all respect including matching colour wash. 542 Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points. 543 Addition for light / fan points with modular type switchin place of piono type switch. 544 Addition for plugpointswith modular switch& socket in place of piano type switch & socket. 545 Supply and wiring of submain with one number 1.5sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit in 20mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. 546 Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor. 547 cable as earth contunity wire etc. complete in all respects. 548 Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor. 549 cable as earth contunity wire etc. complete in all respects. 550 Supplyfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . 551 SUBHEAD II-INSTALLATION OF LIGHT FIXTURES AND FANS 552 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects. 553 Supply & fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AAA) 554 Supply & fixing of LED Tube Light with batten suitable for up to 2 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AAA) 555 Supply & fixing of recess mounting round 10 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.(CAT: AAA) 556 SUBHEAD III-DISTIBUTION BOARD 557 Supply and fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects. 558 6 Way TPN (CAT A) 559 Supply and fixing of 6Amp to 32 Amp(10 KA) MCB in existing MCB, DB complete with connections as required. (CAT A) 560 Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 561 63 Amp. 4 Pole MCB (CAT B) 562 Supply and fixing of power plug with 15A/250 V flush type modular switch and 5 Pin 15 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 563 Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for proper completion of work. 564 Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. 565 SUBHEAD IV-CABLES 566 Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size. 567 16 sqmm4 core 568 25 sqmm3.5 core 569 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 570 16 sqmm4 core 571 25 sqmm3.5 core 572 Supply and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 573 16 Sq.mm 574 25 Sq.mm 575 Plumbing Works 576 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia 577 Providing and fixing 100 mm sand cast Iron grating for gully trap. 578 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 579 100 mm nominal dia Pipes 580 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 581 20 mm dia (iner fitting) 582 32mm dia (outer fitting) 583 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end):. 32mm dia 584 32mm dia 585 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore 586 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore 587 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 588 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 589 Total Cost of Plumbing Work-A 590 TUBE WELL 591 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia 592 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 593 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineerin-charge. 594 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 595 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 596 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 597 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 598 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 599 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewellas per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 600 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 50 mm nominal bore 601 Providing and fixing Kirloskar 3.7 kiloWatt 5 LPS Three Phase-Submersible Pump Set 602 Kiosk (03 Nos) 603 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil 604 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m 605 Supply and stacking of fly ash conforming to IRC- 58 at site. Including carriage, loading , unloading and stacking upto any lead 606 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 607 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 608 16.78 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 609 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 610 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 611 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 612 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 613 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 614 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 615 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 616 All work up to plinth level 617 All work above plinth level 618 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 619 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 620 Surface dressing on new surface with paving bitumen of grade VG - 10 of approved quality using 2.25 kg of bitumen per sqm with 1.65 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete: 621 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 above plinth level superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 622 Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 623 P/L water proofing treatment on roofs. 624 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 625 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of H section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. U cleat The shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thicknessof 20 mm and 1 mm (± 0.1 mm) wall thickness . The panelsfilled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturers specification anddirection of Engineer-in-charge. 626 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete : 9.73.3 100x125x27x5 mm 627 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin-Charge. 628 Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete. 629 providing 40x5 mm flat iron hold fats 400 mm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150mm 1:3:6 mix. 630 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. thermo-Mechanically Treasted bars of grade Fe-500D or more. 631 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand) 632 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :8.14.2 Red sand stone - Exposed face machine cut and tablerubbed with rough backing 8.14.2.4 40 mm thick 633 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand 634 40 mm thick marble chips flooring rubbed and polished to granolithic finish, under layer 34 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 6mm thick with white, black, chocolate, grey, yellow or green 11.0 FLOORING SUB HEAD : 11.0 FLOORING 235 SUB HEAD : 11.0 FLOORING 236 Code Description Unit Rate No. marble chips of sizes from 1 mm to 4 mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 marble chips) by volume, including cement slurry etc. complete 635 Dark shade pigment with ordinary cement 636 Distempering (new work - Two coat or more coats ) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including water thinnable priming coatwith cement primer of approved brand & manufacture after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.(Ceiling) 637 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 638 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. 639 Providing and fixing Aluminim Tower bolts 640 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 641 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. 9.114.1 Triple strip vertical type 642 Centering and shuttering including strutting, propping etc. and removal of form for 643 Foundations, footings, bases of columns, etc. for mass concrete 644 Columns, Pillars, Piers, Abutments, Posts and Struts 645 Lintels, beams, plinth beams, girders, bressumers and cantilevers 646 Lintels, beams, plinth beams, girders, bressumers and cantilevers 647 Suspended floors, roofs, landings, balconies and access platform 648 Engraving in hard stone 649 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover 650 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels 8.2.2 Granite stone slab of colour black, Cherry/Ruby red 8.2.2.2 Area of slab over 0.50 sqm 651 Providing and laying pressed clay tiles (as per approved pattern 20 mm norminal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2 % integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 and finished neat complete 652 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges, making and finishing the outlet complete. 653 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 654 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 655 Electrical Works 656 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 657 Group C 658 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 659 Group C 660 Twin Control Point wiring in PVC conduit, with modular type switch :- 661 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular switch, suitable M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 662 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 663 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 664 Circuit / Sub main wiring in PVC conduit :- 665 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 666 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. 667 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (DB to switch board) 668 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 669 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 670 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire 671 4 x 16 sq.mm. + 2 x 6 sq.mm. Earth wire 672 S/F light plug point Modular type accessories :- 673 Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providingandfixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required. 674 S/F power plug point modular type accessories :- 675 Supply and fixing of suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required. 676 S/F modular type electronic fan regulator :- 677 Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 678 2 Module 679 S/F modular type blanking plate :- 680 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 681 1 Or 2 Module (75mmX75mm) 682 3 Module(100mmX75mm) 683 4 Module(125mmX75mm) 684 6 Module(200mmX75mm) 685 8 Module(125mmX125mm) 686 DISTRIBUTION BOARDS & MCBs 687 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 688 12 way (4 + 36), Double Door 689 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 690 8 way , Double door 691 12 way , Double door 692 Supplying and fixing followingway, horizontal type TP&N, sheet steelMCB distribution board,415 V on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 693 6 way (4 + 18), Double door 694 8 way (4 + 24), Double door 695 12 way (4 + 36), Double door 696 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 697 SINGLE POLE 698 Single Pole 699 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. 700 2 Pole 40A, 30mA 701 2 Pole 63A, 30mA 702 SH:- II- Fitting & Fixtures 703 SITC of following ratings RECCESS /SURFACE MOUNTED LED ROUND / SQUIRE SHAPE DOWN LIGHT liminiaire with pressure dia cast housingFOR SINGLE PHASE supply voltage luminaire shall be confirm to IS 10322 Part 3 section 2 or IEC 6-7 22 with all necessary accessory item required . 704 Supply and fixing recessed mounting LED light, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt.LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 705 10Watt, color temp 3000-6500k as required. (Wall Light) 706 Supply and fixing recessed mounting LED light, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt.LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 707 12Watt, color temp 3000-6500k as required. (Mirror Light) 708 GST Extra As per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
11.
Housing Urban and Rular Development #8660668 AOC
Tender For Construction Of State Tax Office Building At Gauripur Checkpost District Baghpat - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 In all kind of soil upto 1.5m depth R.W 3 In all kind of soil upto 1.5m to 3.0m. depth 4 In all kind of soil upto 1.5m to 3.0m. Depth R.W 5 In all kind of soil upto 3.0m to 4.5m. depth 6 In all kind of soil upto 3.0m to 4.5m. Depth R.W 7 In all kind of soil4.5m to above . Depth R.W 8 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 9 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 12 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in R.C.C. Raft foundation and footing with approved stoneballast. (Using1:1.5:3Mix concrete)M-20 13 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) foundation 14 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : 15 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR SLAB] 16 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.R.W 17 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR BEAM] 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR COLUMN] 19 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).[FOR arches, archribs, domes] 20 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:4 (1 cement : 4 coarse sand) 23 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Same as in item no. 11 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 26 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 27 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 28 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] 29 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 30 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 31 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) DRAIN 32 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 33 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the approved make & colours) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 34 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete. 35 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 36 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 37 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).warehouse 38 Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat) 39 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) 40 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 41 Making grooves 12mmwide x12mm deep in plaster of the walls or in ceiling vertically or horizontally as required 42 Making of draing along with apron 150 X 150 MM 43 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 44 Supply and fixing of flush Doors commercial quality conforming to I.S. 2202 Part 1 (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges bolts locks handles springs fitting with necessary screws to be supplied 35 mm thick single leaves 45 Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. 46 Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. 47 Providing and fixing SS handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. 48 Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (SAL WOOD) 49 12 mm thick one side Pre-laminated particle board (decorative lamination on one side) for Door Chaukhat Paneling 50 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.(Second class teak wood) 51 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges andscrews and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 52 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(GATE)/OHT 53 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 54 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required diaand size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : (Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) 55 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) 56 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 57 (Fixing of Door, windows/ventilators chaukhats in position. Door 58 (b) Windows 59 (c) Clerestory window chowkhats 60 Float glass panes (4 mm thick glass pane (weight not less than 10kg/sqm). 61 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc.Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Threetrackthreepanelsslidingwindowwithtwoglazed &onewiremeshpanelswithAluminiumchannelforroller track,woolpile,nylonrollerswithSS304body. UsingR3serieswithframe(98mm&above)x (40mm&above)&bothglazedandflyscreen sash(30mm&above)x(55mm&above) withzincalloy(Zamak)powdercoatedhandle oneveryglazedpanelalongwithmulti-point lockingsystem.(Heightupto1.8m). 62 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangementsfor inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover 63 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture GATE 64 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 65 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 66 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 67 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 68 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 250 mm x 10mm 69 (a) 200 mm x 10mm 70 Providing and fixinganodised handles with screws etc. complete (a) 125 mm. 71 Foundations, footings, bases of columns, etc. for mass concrete 72 Suspended floors, roofs, landings, balconies and access platform 73 Lintels, beams, plinth beams, girders, bressumers andcantilevers 74 Columns, Pillars, Piers, Abutments, Posts and Struts 75 Columns, Pillars, Piers, Abutments, Posts and Struts 76 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 77 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 78 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement 79 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 80 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer 81 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out asper specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) 82 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish oftapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 83 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 84 Direction & Place identification Signs more then .90sqm size BordP/Erectung direction & Place identification retro-reflectorised sign as per IRC-67 made of high intensity grade sheeting the retro-reflective sheeting type-IV shall be lested for 3 year outdoor weathering. 85 Providing, fabricating and fixing/ erection of 4-5mm SS plate in approved shade at desired location as per approved drawing of SALE TAX OFFICE BUILDING GAURIPUR BAGPAT having Helvetica Font with 75 mm size Also including cost of providing and fixing of fasteners complete in all respects as per Engineer in charge 86 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller8 including making good the undulations etc. and re-rolling the subWC .g rade and disposal of surplus earthwith lead upto 50 metres. (DSR-16.1) 87 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin-chargeCement concrete manufactured in automatic batching plant (RMC plant) including transportation to site in transit mixer. (DSR 16.43.2) 88 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade A sealing compound. (DSR- 16.46.1) 89 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge 90 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by usingplate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 91 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 92 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 93 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid 94 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 95 Providingandfixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting andmaking good the walls where required : White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 96 Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mmbrass pillar taps, brass chain with rubber plug, 32mmbrass waste of standard pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps 97 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. 98 Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern 99 Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 100 Range of four urinal basins with 10litre white P.V.C. automatic flushing cistern 101 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge 102 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 103 Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 510x1040 mm bowl depth 250 mm 104 Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting CompleteFlexible Pipe 32mm Dia 105 40mm Dia 106 Bottle trap 31 mm single piece moulded with height of 270 mm, effProviding and fixing PTMT Bottle Trap for Wash basin and sink. ective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 107 Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.(sink & urinal) 108 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm 109 Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. 110 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 111 Providing and fixing toilet paper holder :C.P. brass 112 Providing and fixing soil, waste, vent pipesCentrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe 113 Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe 114 Providing and fixing heel rest sanitary bend, in Centrifugally cast (spun) iron pipe S&S 100mm 115 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100X100X100mm Sand cast iron S&S as per IS : 3989 116 Providing and fixingPLAIN JUNCTIONof required degree 100X100X100mm Sand cast iron S&S as per IS : 3989 117 Providing and fixing terminal guard: 100mm Sand cast iron S&S as per IS - 3989 118 Providing and fixing collar. 100 mm Sand cast iron S&S as per IS - 3989 119 Providing and lead caulked joint 100 Dia 120 Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989 121 Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work100mm dia 122 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 123 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 124 Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 125 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm nominal outer dia pipes 126 20 mm nominal outer dia pipes 127 25 mm nominal outer dia pipes 128 32 mm nominal outer dia pipes 129 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall 15 mm nominal outer dia pipes 130 20 mm nominal outer dia pipes 131 Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work25 mm dia, nominal bore 132 40 mm dia, nominal bore 133 40 mm dia, nominal boreOHT 134 50 mm dia, nominal bore 135 65 mm dia, nominal bore 136 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)25mm dia, nominal bore 137 32 mm dia, nominal bore 138 40 mm dia, nominal bore 139 65 mm dia, nominal bore 140 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore 141 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diameter Providing and fixing brass stop cock of approved quality : 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 143 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)15 mm nominal outer dia pipes 144 20 mm nominal outer dia pipes 145 25 mm nominal outer dia pipes 146 32 mm nominal outer dia pipes 147 40 mm nominal outer dia pipes 148 65 mm nominal outer dia pipes 149 Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality25 mm dia, nominal bore 150 40 mm dia, nominal bore 151 50 mm dia, nominal bore 152 65 mm dia, nominal bore 153 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work 25 mm dia, nominal bore 154 40 mm dia, nominal bore 155 50 mm dia, nominal bore 156 65 mm dia, nominal bore 157 Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)15mm nominal bore 158 20mm nominal bore 159 25mm nominal bore 160 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 161 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore 162 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore 163 Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia 164 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 165 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 166 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete150 mm diameter 167 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe 168 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than100x100 mm size P type 169 150x100 mm size P type 170 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia rcc pipe 171 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 gradeInside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 172 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 173 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 174 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM 175 75 MM 176 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 110 mm 177 75 mm dia 178 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion.Coupler110 mm 179 Bend 87.5°110 mm bend 180 75 mm bend 181 Shoe plain 110 mm bend 182 75 mm bend 183 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 184 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 185 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :With 20x20 mm square bar 186 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 187 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 188 Providing & fixing 75mm dia vent pipes. 189 Providing & fixing of 75mm dia cast iron terminal guard. 190 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. 191 H.D. -20- Circular shape 560mm internal diameter 192 M.D. -2.5- Circular shape 450mm internal diameter 193 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 194 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 195 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 196 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 197 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 198 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 199 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 200 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 201 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 202 Wiring for group controlled ( looped ) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 203 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 204 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 205 25 mm 206 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 207 3 pin 5/6 A socket outlet 208 TV antenna socket outlet 209 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 210 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 211 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) 212 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 213 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 214 Supplyingandfixing3pin5Aceilingroseon the existing junction box/woodedn blockincluding connectionetc. as required. 215 LayingofonenumberPVCinsulatedandPVC sheathed/XLPEpowercableof1.1KVgradeof following size direct in ground including excavation,sandcushioning,protectivecoveringand refilling the trench etc. as required. Upto 35 sq. mm 216 Supplying&makingendterminationwithbrass compressionglandandaluminiumlugsforthe following size of PVC sheathed / XLPE aluminiumconductorcableof1.1KVgradeasrequired.2 X 10 sqmm. (19mm) 217 Providing,layingandfixingfollowingdiaG.I. pipe(mediumclass)ingroundcompletewithG.I. fittings including trenching (75 cm deep) andrefilling etc as required.50 mm Dia 218 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 219 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 220 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed S teel/ PVC conduit as required. 1 run of cable 221 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 222 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 223 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 224 6 way (4 + 18), Double door 225 12 way Bouble door G.Room 226 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door 227 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole. 228 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 229 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB 230 Supply and fixing of 40 Amp. FP MCB (10 KA) C Curve. CAT A 231 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 232 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 233 63 A 234 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 235 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 236 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 237 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 238 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness 239 300 mm width X 50 mm depth X 1.6 mm thickness 240 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 241 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, ), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 242 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 243 size 35 sq mm x 3-1/2core 244 size 185 sq mm x 3-1/2core 245 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypeIncoming -400 Amp MCCB-1 No.Outgoing - 100 Amp 4P MCCB - 3 Nos. (for VTPN D.B. DBs)63 Amp 4P MCCB - 2 Nos. (or As per requirment directed by Project Manager.) Outdoor Fidder Pillar Panel : 246 400 Amp MCCB-1 No.Outgoing - 100 Amp 4P MCCB - 3 Nos. (for VTPN D.B. DBs)63 Amp 4P MCCB - 2 Nos. (or As per requirment directed by Project Manager.) Outdoor Fidder Pillar Panel :Incoming -400 Amp MCCB-1 No.Outgoing - 200 Amp 4P MCCB - 2 Nos. 100 Amp 4P MCCB - 1 Nos.63 Amp 4P MCCB - 1 Nos. (Spare)(or As per requirment directed by Project Manager.) 247 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 248 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 249 Supply of factory made 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 250 Supply & fixing of 400 mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 251 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc. Decorative Light with 12 W LED Bulb Complete in all respect. CAT. - AAA 252 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 253 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 254 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. 255 Supply and fixing of 1x36 to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA 256 Supply and fixing of 1x36 to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect CAT. - AAA 257 Supply & fixing of recess mounting round 1x6 to 8 watt LED Ceiling Lighte complete in all respect. 258 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Make : Notofire/Honeywell/Tyco Two loop panel 259 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. Make : Notofire/Honeywell/Tyco 260 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.Make : Notofire/Honeywell/Tyco 261 Supplying, installation, testing & commissioning of addressable manual call point complete as required. Make : Notofire/Honeywell/Tyco 262 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. Make : Notofire/Honeywell/Tyco 263 Supplying, installation, testing & commissioning ofaddressable horn cum strobe complete as required.Make : Notofire/Honeywell/Tyco 264 Supplying, installation, testing & commissioning ofaddressable fire control module complete as required.Make : Notofire/Honeywell/Tyco 265 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 266 SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Kartar/Newage/Minimax) 267 SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Kartar/Newage/Minimax) 268 SITC of Short Branch Pipe as per IS:903(Make : Kartar/Newage/Minimax) 269 SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle (750 x 600 x250 mm Size) 270 Providing and fixingMS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser) Make : Jindal80mm dia 271 100mm dia 272 150mm dia 273 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required . (Make : Kartar/Newage/Minimax)Single headed Gunmetal 274 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. (Make : Kartar/Newage/Minimax) 80mm dia 275 100mm dia 276 150mm dia 277 Supply, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories.(Make : Kartar/Newage/Minimax) 278 Supply of Fire Man Axe. 279 SITC of Air vessel made of 250 mm dia , 8 mm thick M.S. sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shed as required. 280 Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. (Make : Kartar/Newage/Minimax) 100 mm 281 SITC of Butterfly Valve complete with all respect.(Make : Kartar/Newage/Minimax) 100 mm 282 Supply, Installation, Testing & Commissioning of Pressure Gauge with gauge cock 283 Supply, fixing , testing & commissioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt)(a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.(b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class B insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of its rated discharge at 65% of rated head.© Common bed plate of fabricated mild steel channel or cast iron type.(d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel.(f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CTs protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minuteHead : 35 meter 284 Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Make: Firejeet/Minimax 285 Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.Make: Firejeet/Minimax 286 Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. Per liters capcity. 287 Supply and fixing of 16 mtr High mast Shaft of approved make with rising system, hot dip Galvanized inside & outside, having pole sheet thickness 3 mm. Top dia minimum 150 mm, bottom dia minimum 360 mm, base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 &.having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes,1.5 HP Power tool motor, 3 point suspension system with steel wire rope 6 mm dia, double drum winch. Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers, anchor plates etc.Complete in all respect as per direction and satisfaction to the Engineer-in-charge. 288 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in allrespect. complete in all respect. CAT AAA 289 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following sizesize 10sq mm x 2 core 290 size 16 sq mm x 4 core 291 size 10 sq mm x 2core 292 S/F of 6mtr G.I Octagonal pole of approved make (Top dia 70 mm, Bottem dia 130 mm and Base plate 12mm thick ) having 3mm thikness with single arm bracket 1mtr length in 1:2:4 R.C.C foundationbolt including the cost of foudation ,excavation & back filling & required TNP Complete in all respect. 293 S/F of LED street light Fitting having Die cast aluminium Body & diffuser with driver set suitable for 75 to 90 watt confirriming to IP 66 & above Protection complete in all respect 294 S/F following capacity of automatic street light cubicle control panel painted with anticorrosive alkali and acid proof paint consisting of timer switch TSO 100 series with contractors HRC fuses, isolating switch Metreing instrument and instrument box with CTS etc. in case of TPN complete in all respects including the cost of fixing materials, labour T & P etc. as per direction and satisfaction to the E/I. 15 A SPN 295 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 296 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 297 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 298 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 299 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting,M.S. Channel Base with bottom and top cable entreis Electricalcontrol panel with TPN MCCBs (Four Pole 36 KA with thermal magnaticrelease)SwitchesComplete and instrumentchamber etc.complete in all respects. The instrumentchamber shall be separate and shall comprise of flushtype digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for differentreadings, instrumentfuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininumbusbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable sidecovers and shall be suitable for extension on the sides. The MCCBs shallbe completewith suitablecable end boxes,compression glands and indicating lamp on incoming etc.The Job includesthe grountingof the board as per directions of Engineer-incharge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shallbe fabricatedwithCRCA sheet with a minimumthicknessof 1.6mm/2mm.Cubicletype switchboard shallbe of cat A & B Only.Incoming :100 Amp MCCB -1 No.Outgoing :63 Amp. MCCB - 1 No. & 32 Amp. MCCB-2 Nos.Cat. B. Pannel Cubicle Type 300 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole. 301 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction ofEngineer-in-charge. 150 mm nominal size dia 302 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 303 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 304 Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. 305 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. 306 Constructing brick masonry INSPECTION chamber 60x60x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete asperdesign. With FPS bricks60x60x60 cm inside 307 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depthPipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 308 Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter 309 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameterS.W. Pipe 310 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. 300 dia & Upto 90 metre depth 311 300 dia & Beyond 90 metre & upto 150 metre depth 312 Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200mm nominal size dia 313 Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. 314 Providing and lowering G.I. pipes complete with G.I. fittings including trenchingand refilling etc. 65 mm dia nominal bore (Column pipe). 315 Supplying, filling, spreading & leveling pea gravel[(3.14/4)*(.3*.3-.2*.2)*140)]=5.50 316 Charges for development by 150 PSI Compressor Per Hr. 317 SITC of Pumping plant including starter, control Panal, cable, complete in all respect with all required material T&P labour etc. [7.50H.P. ] Crompton/K.S.B., Oswal make 318 Supply and wiring of 3 number 6 sq. mm. FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 40mm dia heavy guage rigid steel conduit on surface, with two number 10 SWG copper earth continuity wire etc, complete in all respect From Transformer to Panel 319 Water Supply of tanker 5000 litre capacity of boring. 320 S/F %0 KVA DG Set
Contract Date: Jan 09, 2026 Contract Value : 7.50 Crore
Government Departments No of Bidders 7
Uttar Pradesh View Result →
12.
Law and Justice #8604745 AOC
CONSTRUCTION OF SU-SASTHYA KENDRA (HEALTH & WELLNESS CENTRE) (HWC TYPE-B)” atName of the facility-Roypara Bolhanja, Area-7405, Mouza-Bolancha, JL.No.-50, Kh.No-1,Plot No.-1407 G.P.-Islampur, Block-Islampur- 1 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. 3 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. 4 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)a) With earth obtained from excavation of foundation. 5 B) Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 6 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. 7 a) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.) 8 b) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated). 9 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturers specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). 10 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 11 Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety]i) In Ground floor 12 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.a) [Pakur Variety]i) In Ground floor 13 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyi) In ground floor and foundation 14 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyii) In first floor 15 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyii) In second floor 16 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) SAIL/TATA/RINLi) In foundation & ground floor 17 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) SAIL/TATA/RINLii) In first floor 18 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a) SAIL/TATA/RINLiii) In second floor 19 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete worki) In foundation & ground floor 20 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete workii) In 1st floor 21 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. c) Steel shuttering or 9 to 12 mm. thick approved quality ply board shuttering in any concrete workiii) In 2dfloor 22 Brick work with 1st classBricks with cement morter (1:4)(a)In foundation and plinth 23 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor 24 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor(c) In 1st floor 25 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor(d) In 2dfloor 26 125 mm. thick brick work with 1st class bricks in cement mortar (3:1) i) In ground floor 27 125 mm. thick brick work with 1st class bricks in cement mortar (3:1) ii) In 1st floor 28 Labour for Chipping of concrete surface before taking upPlastering work. 29 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (4:1)i) In ground floor 30 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (4:1)ii) In first floor 31 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.a) 20 mm. thick plaster (4:1)iii) In second floor 32 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (4:1)i) In ground floor 33 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (6:1)ii) In first floor 34 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (6:1)iii) In second floor 35 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.c) 10 mm. thick plaster (4:1)i) In ground floor 36 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.c) 10 mm. thick plaster (4:1)ii) In first floor 37 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.c) 10 mm. thick plaster (4:1)iii) In second floor 38 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 39 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thicki) In ground floor 40 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thickii) In first floor 41 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thickiii) In second floor 42 Extra cost of labour over grey artificial stone for(i) Chequering 43 (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturers specification [Cement to be supplied by the Department] 44 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor)(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light ColourGround Floor 45 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor)(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour1st Floor 46 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m] Ground Floor 47 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m] 1st Floor 48 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeGrond Floor 49 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorative1st Floor 50 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorativeGround Floor 51 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(i) Coloured decorative1st Floor 52 Rendering the surface of walls and ceiling with white cement based wall putty (thickness not less than 1.5 mm.)i) In ground floor 53 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface.a) Two coats 54 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.a) Two coatsi) In ground floor 55 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.a) Two coatsii) In first floor 56 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured( matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC.a) Two coatsiii) In second floor 57 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Two coatsi) Super Premium 100% Acrylic Emulsioni) In ground floor 58 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Two coatsi) Super Premium 100% Acrylic Emulsionii) In first floor 59 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Two coatsi) Super Premium 100% Acrylic Emulsioniii) In second floor 60 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..(i) 66mm x 90mm 61 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 25 mm thickIn ground floor. 62 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.(ii) 25 mm thickIn 1st floor. 63 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.i) In ground floor 64 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.iii) In second floor 65 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.i) In ground floor 66 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.ii) In first floor 67 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) 68 Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. 69 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) -b) On steel or other metal surface :i) Two coats (with any shade except white) 70 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fixing of glass (excluding cost of glass) all complete as per architectural fitting & fixing of aluminium 2-track/3-track sliding window with drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing filmi) Natural Whitea) 2-track sliding window + b) 3-track sliding window 71 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, doorvertical),glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc)10-12 Micron thickness Annodizing film Natural white 72 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteh) Louvered windowi) Top, bottom and sidemember 73 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteh) Louvered windowii)Louvered Section 74 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteh) Louvered windowiii) Cleat angle ( Non-annodized) 75 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteg) Fixed glazingi) Top, bottom and side member. 76 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteg) Fixed glazingii)Mullion. 77 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finishedconforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A)10-12 Micron thickness annodizing filmi) Natural Whiteg) Fixed glazingiii)Glazing clip. 78 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(vii) 100x75x4.00 mm 79 Supplying 4 lever mortice lock of any approved make and brand as per direction of the Engineer-in-Charge.(a) 100 mm 80 Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units(iv)fixed glazing 81 Labour charges for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units(v)Louvered window 82 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.i) 4mm thick clear glass. 83 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.viii) 6mm thick coloured / tinted / smoke glass. 84 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.viii) 8mm thick coloured / tinted / smoke glass. 85 Supplying and affixing optically clear polyester sun control window film having acrylic pressure sensitive adhesive on one side & an acrylic abrasion resistant coating on the other, with composition of infrared absorbing carbon & free from any optical defect. The film characteristics should conform to ASTM E308, ASTM E903, ASTM E84 and ASHIRAE. The film should be pasted after preparatory works without any cracking, delamination, bubbling, discolouring and variation in total transmission of light across the width at any portion along the length doesnt exceed 2% over the average including scaffolding & relevant others to complete in all respect as per manufacturers specification & direction of Engineer -in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)(a) Normal Quality : Film Thickness - 1.0 Mil, Glare Reduction > 45%, U factor < 1.15 86 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.(C) Both side decorative lamination(II) Interior Grade(ii) 12mmi) In Ground Floor 87 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.(C) Both side decorative lamination(II) Interior Grade(ii) 12mmii) In First Floor 88 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(iv) 125 mm grip x 10 mm dia rod. 89 Supplying, fitting & fixing Stainless Steel D or H type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154, of approved quality of reputed brand as per direction of Eingineer-in-Charge fitted and fixed complete including all incidental charges. 90 ii) Godrej Hydraulic door closer fitted and fixed complete.(b) Medium type 91 Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(vii) 225mm long x 10mm dia. bolt 92 Anodized aluminum barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iv) 150mm long x 10mm dia. bolt. 93 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting(b) 250mm long. 94 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii)110 mm. Dia. 95 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.a) Plain Tee(ii)110 mm. Dia. 96 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.b) Plain Y(ii)110 mm. Dia 97 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.c) Bend 87.5 degree(ii)110 mm. Dia. 98 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.d) Shoe(ii)110 mm. Dia. 99 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) 100 Printing New Letters and Figures of any ShadePrinting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 801 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).ii) English and Roman 101 Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor.(a) Slab Thickness 20 to 25 mm 102 Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. Area of each Granite slab > 0.6 upto 1.0 square metre. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] 103 Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge.(Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film.Natural white.a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm(unit wt of Top, bottom & side member @1.366 kg/m ; intermediate member @ 1.443 kg/m; glazing clip: 0.167 kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.7 Kg per Sq.M] 104 Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge.(Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film.Natural white.b) For unsupported length of vertical member above 1.50m. height of both ends of vertical member restrained but panel above 0.90 sqm(unit wt of Top, bottom & side member @ 1.978; intermediate member @ 2.055; glazing clip @ 0.167 kg/m respectively) 105 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. 106 Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(i) 16 mm dia bolt (a) 300 mm long 107 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Exposed WorkPVC Pipes40 mm 108 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Concealed WorkPVC Pipes15 mm 109 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Concealed WorkPVC Pipes20 mm 110 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(b) For Concealed WorkPVC Pipes25 mm 111 Supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)(ix)15 mm dia 112 supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)viii) 20mm 113 supplying ,fitting and fixing peets valve fullway gunmetal standard pattern best quality of approved brand bearing isi markings with fittings (tested to 21 kg per sq.cm)(vii) 25 mm dia 114 Supplying, fitting and fixing bib cock or stop cock.a)i) chromium platedbib cock short body (equivalent to code no. 511 & model- tropical./ sumthing special of ESSCO or similar brand) 115 Supplying, fitting and fixing bib cock or stop cock.(d)i) chromium plated angular stop cock with wall flange (equivalent to code no. 5053 & model- Florentine of Jaquar or similar brand) 116 Supplying P.V.C water storage tank of approved quality with closed top with lid(black)-Multilayer.(c) 1500 litre capacity 117 Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity.(a) Upto 1st story from G.L. 118 Supplying fitting & fixing 10 ltr. PVC low down cistern conforming to I.S specification with PVC fittings complete C.I brackets including two coats of painting to bracket etc. 119 Labour for punching hole in plastic water storage tank up to 50 mm dia. 120 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.ii) 550 mm X 400 mm size 121 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.(iv) Angle back wash basin 400 mm X 400 mm 122 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm 123 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut,15 mm dia.i) 450mm long 124 Suppling fitting & fixingapproved brand 32mm dia p.v.c waste pipe with p.v.c coupling at one end fitted with necessary clampsi)900mm long 125 Suppling fitting & fixing15 mm swan neck tap with left & right hand operating knob with aerator. 126 Suppling fitting & fixing c.i round gratingi)100mm 127 Supply of UPVC pipes (B type )& fitting conforming to IS 13592-1992 A) i) single socketed 3 mtr length --b)110 mm 128 (ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials.A) Above ground(ii) 110 mm dia. 129 (ii) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. A) Under ground(ii) 110 mm dia. 130 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 viii) Double Y with Door b) 110 mm 131 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 xi) door bend ( T.S.)b) 110 mm 132 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992xv) vent cowl-(b) 110mm 133 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992xvi) pipe clip ---(b) 110 mm 134 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Plain Tee---(b) 110 mm 135 Suppling fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with P trap 136 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(a) E.W.C. (ii) Plastic (hallow type) white 137 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.i) Polythene Flush Pipe 138 Supplying, fitting and fixing liquid soap container.(c) Fibre glass 139 Supplying fitting & fixing best quality indian make mirror 5.5 mm thk. With silvering as per I.S.I specification supported on fibre glass frame of any colour,frame size 550mm x 400mm 140 Supplying fitting & fixing towel rail with two brackets.a)C.P over brush--- i)25mm dia,450 mm long. 141 constructing inspection pit of inside measurement 600mm x600mm x upto 600mm (depth) with 250mm th. 1st. Class brick work in cement mortar(1:4) on all sides bottom of the pit consisting of 100 mm th. Cement concrete (1:3:6) with stone chips over a layer of jhama brick fklat soling, 15 mm thk. (4:1) cement plaster to bottom of the pit providing necessary invert with cement concrete (1:3:6) with stone chips as per direction ,neat cement finishing to entire internal surface top of the pit convered with 100 mmth. R.CC slab (1:1.5:3) with stone chips and necessary reinforcement upto 1% and shuttering including 6mm thk.cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia .R.C.C manhole cover of approved make supplied ,fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth removing spoils after work complete in all respect with all costs of labour and materials.i) With pakur variety (SAIL/TATA/RINL) 142 Construction of circular soak well 2.5 m deep inall types of sandy soils with dry brick work upto 1:6 m from the bottom having 150mm intermediate cement brick work(1:4) band all round and cement brick work (1:4) upto .90m from top with 20mm thk. Cement plastering (4:1) to inside face upto the depth of cement brick work, 15 mm th.cement plaster (1:4)on outer face from top of the well upto G.L and 6mm thk. cement plaster (1:4) on top of the R.C.C cover slab including filling bottom 1.0m of inside of the well with brick metal (501mm to 63mm size) including R.CCcover slab of designed thk. with cement concrete b(1:1.5:3) with stone chips with necessary. reinforcement and shuttering including one 560 mmdia .R.CC manhole cover(heavy type) of approved make supplied ,fittings making necessary arrangements for pipe connections ,excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.a) with 250mm thk.dry brick work and 250 mm thk. cement brick work (6:1) and 1.00 m inside dia.For-SAIL/TATA/RINL 143 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C.........(ii) For 20 users(A) With Pakur Variety (SAIL/TATA/RINL) 144 Cement concrete with graded stone balast ( 40mm size excluding shuttering ) in ground floor(A) Pakur variety(a) 1:3:6 Poportion 145 Supply fitting and fixing Fire Exyinguisher conforming to ISI Marked (IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 KGS capacity with intial filling in brand new cylinder with poder coated finish, fitted with gun metal union, discharge house, wall mounting bracket and suitable sinage etc. complete ( Make : Fire Shield/ New age /De Flame/ Andex or equivalent). A level Agency should be pasted on the body of the Extinguisher dully signed& stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/Date of next refiling (warranty card need to be submitted) 146 Supplying, fitting & Fixing EWC (Size- 710x370x810 mm)in white glazed vitreous chinaware of approved make supplying, fitting and fixing in position complete with necessary nut and bolts. (Model Code No. S10221114-P Trap (CRUSE SET) of CERA or equivalent.) 147 Supplying, fitting and fixing 10 litre white glazed vitreous chinaware of approve low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internal fittings. (Model Code No. S1060106 of CERA or equivalent.) 148 b) Soft Close seat cover of approved make with lid and C.P. hinges, rubber buffer and brass screws suppling, fitting and fixing complete. E W C (Model Code No. B1520118 of CERA or equivalent.) White 149 Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.) 600mm Long 150 Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets. (Model Code No.B2210108 of CERA or equivalent.)750 mm long 151 Supplying, fitting and fixing 15 mm Twin Flush Fitting (Model Code No. B1810112 of CERA or equivalent) 152 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 153 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. a) Depth of excavation not exceeding 1,500 mm. 154 B) Filling in foundation or plinth by find sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 155 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 156 Cement concrete (1:3:6 proportion) with graded stone ballast (40 mm. size) excluding shuttering. a) [Pakur Variety]i) In Ground floor 157 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.a) [Pakur Variety]i) In Ground floor 158 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyi) In ground floor and foundation 159 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.a)SAIL/TATA/RINLi) In foundation & ground floor 160 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.ii) Ground floor 161 Brick work with 1st classBricks with cement morter (1:4)(a)In foundation and plinth 162 Brick work with 1st classBricks with cement morter (1:4)(b) In superstructure, ground floor 163 125 mm. thick brick work with 1st class bricks in cement mortar (3:1) i) In ground floor 164 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (4:1)i) In ground floor 165 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 166 Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturers specification.In Ground floor:(iii) Two coats. 167 Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75kg/sq.m all complete including all materials and labour.In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement(ii) 25 mm. thicki) In ground floor 168 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. 169 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs .(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.i) In ground floor 170 Priming one coat on steel or other metal surface with synthetic enamel/ oil bound primer of approved quality including smooth ening surfaces by sand papering etc. 171 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary with super gloss (hi-gloss) -b) On steel or other metal surface :i) Two coats (with any shade except white) 172 Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment). 173 Supplying and stacking sludge (adequate for Horticulturework) at site in dry cake form from approved disposal work site including royalty, all lead and lift etc. (Sludge measured in stack will be reduced by 8%). 174 Spreading of sludge, dump manure,/farm yard manure /animel dung manure and good earth in requiredthickness. This includes supply of labour, tools & plantsexcluding materials. 175 Supplying and fixing grasses tiles of grass MaxicanCarpet/Selection No. 1 Healthy & fresh grasses (size 1x1 or bigger) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from wees and fit for mowing including supplying good earth as required by Engineer-in-charge. (Rate includes supply of labour, tools & plants including materials) 176 Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.xxvii) Areca Palm 4 - 5 suckers of height 120 cm to 135 cm in earthen pots of size 25 cm. 177 Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.iv) Rangon hi-breed healthy plant. 178 Supplying and Planting of different plant / trees ( Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift,carriage, handling, manuring, applying presticide andfertilizer etc.xvii) Bougainvillea (mix variety) of height 30cm-90cm inpolybag of size 10cm-15cm. 179 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.(i) 50 mm dia. boring etc. 180 Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia.(ii) 100 mm dia. boring etc. top enlargement 181 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia)50 mm 182 Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia)100 mm 183 Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.(ii) 50 mm dia. 184 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-inchargeincluding cost of all materials labour and equipment complete. 185 Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. 186 Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. 187 Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.(ii) 50 mm 188 Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm 189 Supplying, fitting and fixing G.I. cap at top(i) 100 mm 190 Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with V notch including hire and labour charges for all tools and plants and scaffolding as required. 191 Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete. 192 Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. 193 Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. 194 Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. 195 Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately)(iv) 32 mm dia. medium quality 196 Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).(vi) 32 mm dia 197 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes32 mm 198 Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per sq. cm.(vi) 50 mm 199 Supply and delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034 (and as amended thereafter) with standard MOC for potable clear cold water and BEE 3 star rared capable of discharging noted M3/hr against head of water column. The pump shall be directly coupled with a continuous rated 2-pole suitable wet type vertical squirrel cage induction morter conforming to IS : 9283 (and as amended thereafter), suitable for operation in AC single phase 220V 50HZ (category B motor) as per specifiation and direction of EIC. 1Ph 230 V , 1.5 HP submersible pump Make- Crompton Groves/ CRI/ Sieners. 200 Supply and delivery of direct on line (DOL) strater panel board conforming to IS13947 and IEC 947 of suitable HP rating for operation in 230 V (±10%) comprising of anmeter, voltameter, thremal overload realy, 2 pole magnatic contactor, undre voltage protection, indicating lamp, capacitor, wiring with 1/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities- as per satisfication and direction of EIC. 1) 1.5 HP (Retay Range 9-14 Amp.) 201 Supplying, delivery & Installation of Submerssible Starter Panel (L&T Make) with appropriate overload and overcurrent protection. 202 Supplying and delivery and fixing of 2.5 Sq.mm 3 core flat PVC cable (Finolex or equivalent) for submerssible pump motor etc. 203 Supplying and fixing C.I. water proof looping cable box having hinged top cover having 4 mm thick with rubber gasket living railway type mechanical locking arrangement earthing terminal with lug etc of size 8X6X4 comprising 3 Nos. 15 amps Kit-Kat fuse unit and housing the same in pole muffing. 204 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. 205 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. 206 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. 207 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)a) With earth obtained from excavation of foundation. 208 B) Filling in foundation or plinth by find sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 209 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand. 210 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes.a) [Pakur Variety]i) In Ground floor 211 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codesa) M-20 grade with Pakur varietyi) In ground floor and foundation 212 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.I. SAIL/ TATA/RINLi) In foundation & ground floor 213 Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.ii) Ground floor 214 Brick work with 1st classBricks with cement morter (1:4)(a)In foundation and plinth 215 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary.b) 15 mm. thick plaster (4:1)i) In ground floor 216 Boring / drilling bore well of required dia for casing/strainer pipe, by sutable method prescribed in IS:2800(Part-I), including collecting sample from different strata, preparing and submitting starta chart/ bore log including hire & running charges of all equipment , tools, plant & machineries required for the job, all complete as per direction of Enginnering-in-charge, upto 90 meter depth below ground level. IS:2800(Part-I), including collecting sample from different strata, preparing and submitting starta chart/ bore log including hire & running charges of all equipment , tools, plant & machineries required for the job, all complete as per direction of Enginnering-in-charge, upto 90 meter depth below ground level. 23.1.1 All type of soil 23.1.13 400 mm dia 217 25.1.2 for Rocky strata including boulders 23.1.2.3 400 mm dia 218 Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm X 200 mm 219 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia 220 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.4.3 200 mm nominal size dia 221 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 222 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge. 223 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 224 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. 225 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 23.15.3 200 mm dia 226 Supplying, fitting and fixing in position R.C.C. Manhole/ pit cover of approved make with rim of approved make (Heavy type) (ii) 560 mm dia. 227 R.C. shelves (1:1.5:3) either precast or cast in situ with stone chips and necessary reinforcement upto 1% (0.8% main and 0.2% distribution bars), shuttering etc. and 10 mm. thick cement plaster (1:4) including neat cementfinishing and cutting chase fitting and fixing in position, mending good damages as necessary complete.In ground floor(a) 50 mm. Thick panelsI. SAIL/ TATA/RINL 228 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. 229 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.a) Plain Tee(ii) 110 mm. Dia. 230 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.c) Bend 87.5 degree(ii) 110 mm. Dia. 231 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid /Bitumen /M-Seal etc) complete.d) Shoe(ii) 110 mm. Dia. 232 Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)PVC Pipes(Dia)80 mm 233 Renewing gully grating.(i) 375 mm X 300 mm X 40 mm X 18 kg New work 234 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length b) 110 mm 235 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A)xv) Vent Cowl b) 110 mm 236 Providing weep holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications. 237 Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohrs hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturers specification and direction of Engineer-in-Charge.In Ground Floor: Sizes-300 mm x 300 mm x15 mm 238 Supplying and laying true to line and level Tactile Finish Scratch resistant, Neutral to UV rays, Non-fade, High Slip Resistant Full Body Vitrified Tiles conforming to IS:15622-2006 & IS :4457- 2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohrs hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%], MOR > 38N/sq.mm & Breaking strength > 4000 N for Outdoor area of building e. g. Driveway, Pathway, Pavements, Parking lots, Sloping ramps, Entrance lobbies, Patios, Portico, swimming pool enclosure, Bus Passenger Shed & directing visually impaired persons, set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturers specification and direction of Engineer-in-Charge.In 1st Floor: Sizes-300 mm x 300 mm x15 mm 239 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 240 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph.& N) and 1x22/0.3 as ECCAverage run 6 mtr 241 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph.& N) and 1x22/0.3 as ECCAverage run 7 mtr 242 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph.& N) and 1x22/0.3 as ECCAverage run 8 mtr 243 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed] Average run 9 mtr 244 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(b) 3 x 22/0.3 (1.5 sqmm) 245 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(s)2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 246 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(v)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 247 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required(y) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC 248 Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).(b) 19mm dia 3mm thick Polythene Pipe 249 Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).(c) 25mm dia 3mm thick Polythene Pipe 250 Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works19 mm dia 3 mm thick polythene pipe without earthcontinuity wire 251 Cutting channel of 43 mm x 43 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works 19 mm dia 3 mm thick polythene pipe without earth continuity wire(a) 25 mm dia 3 mm thick polythene pipe without earth continuity wire 252 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy.. PVC fittings etc. and mending good damages to building works20x10mm Size 253 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy.. PVC fittings etc. and mending good damages to building works25x10mm Size 254 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(i) 2.5sqmm 255 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(ii)4 sqmm 256 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(iii) 6 sqmm 257 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC(i) On Board 258 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr 259 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 260 Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 261 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 262 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 263 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy.Connections. 264 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. 265 Supplym Delivery Installation, Testing and commissioning of indoor cubical type LT distribution panel board along with continuous Neutral & Earthing Indication of required size, wall/stand mounted compertmentalized with maple arrangement having rigid and self supporting structure withcable alloy febricated from 2 mm thick. CRCA sheet steel and M.S. angles frame for panel mounting support and making necessary grouting arrangement with neat cementing finish as per direction of EIC. 266 Supplying and fixing Sheet steel Main Switches onangle iron frame on wall32A DP [Standard/HPL Make] 267 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)2 bars 240 V, 63 A 268 Supplying and fixing Changeover switch with SheetSteel enclosure on flat iron frame on wall with nutsbolts etc32A,240V DP, Make - Standard/HPL 269 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand]2+4 way [EDB 1] (607710) 270 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand]2+8 way [Ground & 1st Floor, NDB 2 & 3] (607711) 271 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [Make - Legrand]2+12 way [Ground & 1st Floor, EDB 2 & 3] (607712) 272 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment[Make - Legrand]2 Way [UPS DB] 273 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment[Make - Legrand]4 Way [NDB 1] 274 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Single pole 6-32A [SPNDB Outgoing] MCB 275 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Single pole 25A [EDB1 Outgoing] MCB 276 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 32A MCB ( EDB1, NDB 2,3) 277 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 32A MCB ( UPS) 278 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 25A [EDB 2,3 Incomer] 279 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand / Hager).Double pole 32A MCB [NDB 1 (NDB 1-4Way) 280 FIXING OF FANSSupply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 281 FIXING OF FANSSupplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 282 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. 283 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12) 284 Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long)For Al :30 cm Exhaust fan (12) 285 Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board 286 Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length 287 Supply & Delivery ofsweep 48 inch(1200 mm) AC ceiling fan 50-70 watts, speed >=350 RPM air delivery >= 220 CMM sutable for [ Make-Orient PSPO New Breeze/ Summer Cool /equvalent of EPC of USHA STRIKER PLUS of CROMPTON [Approved by EIC] 288 Supply & Delivery ofsweep 36 inch(900 mm) AC ceiling fan 50-70 watts, speed >=380 RPM air delivery >= 145 CMM sutable for [ Make-Orient PSPO New Breeze/ Summer Cool /equvalent of EPC of USHA STRIKER PLUS of CROMPTON [Approved by EIC] 289 Supply & delivery of heavy duty exhaust Fan of Sweep:-12 inch (300mm), 240 volt, 50Hz, AC, 50-60 Watts, Speed>900 RPM Air delivery >= 145 CMM suitable for [ Make- Orient/ Model Power Flow)/EPC / Havells/ Crompton Greaves) [Approved by EIC] 290 Supply & delivery of wall fan 16 Sweep metal blade ( Crompton Greaves/ Orient/Havells make) 291 Supplying of 1.1 KV. Grade LT power cable XLPE insulated cores laid up, PVC inner sheathed aluminium armoured conductor of the following Specification (make: Polycab/Gloster/Havells) 16 sqmm2 core (A2XWY/A2XFY) 292 Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting 293 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core upto 16 sqmm 294 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :2 core 16 sqmm cable 295 EARTHING:Soil Excavation :Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil 296 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:[Raw Power-2, UPS:-1]By TATA-Medium GI pipe 297 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 298 Extra for treatment of soil by using salt & charcoal or coke for plate electrode 299 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. 300 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 301 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid GI wireNo. 8 SWG 302 Supply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required 303 Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. 304 Supplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. 305 Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. 306 Supplying and fixing PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works(a) 20mm size 307 Supply & delivery of single 4 battan type LED tube light fitting 1200 mm efficancy >= 100 lm/W THD< 10 %complete with all accessories [Make havells/LED Pride Plus NXT Batten 22 W 6500K) or equivalent of Philips, Crompton etc. [Approved by EIC] 308 Supplying & Fixing Out door type CFL/LED luminaire (Havells make- LHRC4185099 or equivalent) with deep drawn aluminium housing anodised inside & clear acrylic cover and accessories incl. for 85 watts CFL lamp incl. S&F 32mm dia GI pipe bracket, clamp, nut & bolts etc. 309 Supply & Delivery at site of 9 Watt LED Bulb Efficancy>= 90lm/W Base Cap :- B22 (Make- Havells, LEDDEKOR BULB 9W B22 CDL] or equivalent Crompton, Philips etc.[Approved by EIC] 310 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener 311 Fixing only lamp 312 Supply & delivery of 550 Wp or above Mono-PERC/N-Type TOPCON, 144 Half-Cell Monofacial/Bifacial Module with Min. Module Efficiency 21.3%, IEC & BIS Certified (Manufactured in India) with Annual Degradation Not More Than 0.60%. [Manufacturers Authorization is mandatory].[Make:- RenewSys/Panasonic/Waaree][Approved by EIC] 313 Solar InverterSupply & delivery of Single Phase Hybrid Inverter with Inbuilt MPPT Charge ControllerSize: 3.5 KVA/48 Vdc.[Manufacturers Authorization is mandatory].[Make:- Luminous/Flin Energy/Deye][Approved by EIC] 314 Supply & delivery of Module Mounting Structure of HDGI (86 Micron) with Initial Height of 500mm from Roof Level, Withstand Wind Speed of 150 Km/Hr. (Min 56 kg/kW) with All SS304 Fasteners 315 Lead Acid Battery (ESS)Supply & delivery of Solar VRLA Gel Maintenance Free 12V-100Ah Battery @50% DOD with Battery Cable & Accessories (5 Years Warranty)[Make:- Exide/Luminous/Amara Raja][Approved by EIC] 316 DC Solar CableSupply & delivery of DC Solar Cable 1C x 10 Sqmm 1.5 kV Grade XLPO Insulated Tinned Copper (UV Outdoor Cable)[Make:- Polycab/APAR/LAPP][Approved by EIC] 317 Earthing CableSupply & delivery of Earthing Cables 1C x 25 Sqmm 1.1 kV Grade PVC Insulated Flexible Copper G/Y[Make:- Polycab/Mescab/KEI] [Approved by EIC] 318 LT Distribution & Battery CableWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC 319 LT Distribution & Battery CableWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 320 LT Distribution & Battery CableWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 321 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+4 way [Enclosure (DHDPSNODRW04)] [Solar Main AC DB][Make:- Havells/Legrand/BCH] [Approved by EIC] 322 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+8 way [Enclosure (DHDPSNODRW08)] [Solar AC DB-Gr. & 1st Fl.][Make:- Havells/Legrand/BCH] [Approved by EIC] 323 Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.32A DP Isolator [For Solar Main AC DB][Make:- Havells/Legrand/BCH] [Approved by EIC] 324 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection6-32A SP MCB [Solar AC DB-Gr. & 1st Fl.][Make:- Havells/Legrand/BCH] [Approved by EIC] 325 Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc32A 240V DP Changeover Switch[Make:- Standard/L&T/BCH] [Approved by EIC] 326 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(a) 150 mm x 100 mm x 65 mm 327 Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works(a) 150 mm x 100 mm x 65 mm 328 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required(a) 100 mm x 100 mm x 65 mm 329 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required(b) 150 mm x 100 mm x 65 mm 330 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required(b) 150 mm x 100 mm x 65 mm 331 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. 332 Supply & Delivery of 24V DC Battery Cable Set with MCB Configuration[Make:- Polycab/Mescab/KEI] [Approved by EIC] 333 AC-DC Distribution BoxSupply & Delivery of AC-DC Integrated Distribution Box with Over Current (PV Fuse 1000V 15A) & Surge Protection (DC & AC SPD Type 2)[Make:- Fender Energy/Earth Energy Solutions] [Approved by EIC] 334 Earthing & Lightning Protection WorkEarthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below:-By TATA-Medium GI pipe [AC DB Earthing] 335 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [AC DB Earthing] 336 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [AC DB Earthing] 337 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 338 Supply and Delivery of 1 x Copper Air Terminal with Mast, 2 x 2m x 17.2mm Copper Bonded Earth Electrode, 2 x Backfill Compound, 2R x 16Sqmm Flexible Copper Earthing Cable, 2 x CI/FRP Pit Chamber CoverPit at DC Side: 2 Nos. 339 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes Pakur variety [for fixing of mounting structure on roof slab] 340 Fire ExtinguisherSupply, Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC04 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -1A & 13B 341 Supplying and fixing PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building worksb) 25mm size 342 Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.With out angle iron support [100x50x1.25mm (18SWG)] 343 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(i) 2.5sqmm 344 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(ii) 4 sqmm 345 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(iii) 6 sqmm 346 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core:- upto 2.5/4 sqmm 347 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core:-upto 6 sqmm 348 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core:-upto 25 sqmm 349 Supply & Delivery of MC4 Connectors, PVC/M.S. Saddles, Bullets, Screws, Fasteners, Ferrule, Cable Tie, Spare Tools, Caution Board, Safety Signage and other Electrical Accessories as required for setting up of 2.2 kWp solar power plant 350 SITC & Comprehensive Maintenance of Solar PV Power PlantDesign, Engineering, Installation, Testing, Commissioning & Additional 1 Year of Comprehensive Maintenance Work for Off-grid Rooftop Solar PV Power Plant (2.2 kWp) at Su-Swasthya Kendra (Type-B) 351 Control PanelSupply, installation, and commissioning of a microprocessor/microcontroller-based, networkable, intelligent, analogue addressable single-loop control panel, expandable up to 4 loops. The control panel is designed with ARM Cortex-M4 32-bit Microcontroller with high resolution (480 X 272 pixels) 4.3 inch graphics TFT LCD displaywith symbolic representation for power status, displays color-coded events (like Red, yellow & Amber ).The system status and control keys with symbolic representation for easy access.The control panel has inbuilt multilingual features (English and Bengali).The panel status shall be visualized on LCD/LED in unambiquese color. The system should support for the 140 Nodes maximum in a Network including Repeater panels & NAC Extender Power supply panels. The total Network Distance shall cover upto 16 Kms for peer to peer network and 1.2 Kms for Repeater & NAC Extender power supply panel network. This panel can operate as a standalone or connect up to 16 panels in a network via Network Interface Card (NIC) for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the panel configuration using the Configuration tool, Two inbuilt programmable inputs, Two inbuilt programmable NACs with short circuit protection, Programmable 24VDC (Steady/Reset) and TwoProgrammable Relays, One dedicated Fault Relay, 10000 events log with RTC, Numaric keypad for menu access. The panel should be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of 250 intelligent analog addressable devices in one loop in anycombinations including loop powered sounder,sounder-strobe etc. the system has high reliability with the capacity to support 16,000 devices in any combination. The central processing unit shall containand execute all [Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] [Including 5 Years Comprehensive Warranty] 352 Addressable Multi SensorSupply ,Installation and Commissioning of analog Addressable Multi Sensor - Heat Cum Smoke detector with ROR featues to raise an alarm when the temperature reaches 11.1°per Minute withbase, Binary coded address setting DIP switch. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42. Approval: UL or FM.[Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] 353 Addressable Manual Pull StationSupply, Installation and Commissioning of analog Addressable Manual Pull Station - DoubleAction with inbuilt fault isolator, shall be resettable by Key lock access to avoid unauthenticated restorations,FR - ABS Housing, monitoring the field NO/NC devices. Shall have Binary Coding Setting Dip Switch, The MCP shall have operating temperature range from 0°C to 49°C and humidity tolerance range up to 93% RH, Non-Condensing. Complete with termination and testing as per requirement and as per specification. [Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] 354 Supply, Installation and Commissioning of Manual Pull station back box (Single Gang Box) compatiable with manual pull station single/dual action equipped with blinking LED for normal condition and steady LED for manual pull station activated condition along with 8 way dip switches for addressing the devices.[Make:-Aaral/ Simplex/Ravel/Notifier][Approved by EIC] 355 SounderSupply, Installation and Commissioning of wall mount loop powered sounder - Strobe withbuiltin isolatorfixing box having minimum sound pressure level of 85dBA @3mtr, Flash intensity should be 15cd minimum Candela Low and High can be selected from FACP,flasherfrequency1HZ per second, shall have 8 Different tone selection from FACP ,Adjustable volume control,Sounder and strobe OFF facility.It shall be RED in colour.Complete with termination and testing as per requirement and as per specification,Material -FR ABS Plastic,Temperature range 0-49deg C , Shall have Binary Coding Setting Dip Switch,Dimensions (100.5 D x 72.25H)mm. Cable wiring for the termination should be at base of sounder and head shall be installed seperately. IP Rating- IP60 356 CableSupply ,Installation and Commissioning of armoured 2 C X 1.5 Sq mm FRLS Twisted Pair Tinted copper multistranded cable (Red Color) for Fire Alarm System. Complete with termination and testing as per requirement and as per specification.[Make:-Finolex/ Plaza/Polycab/ RR Cable] [Approved by EIC] 357 LT Distribution, MCB DB & Switch BoardWiring in 1.1 KV grade single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.(b) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 358 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment2 Way 359 Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection10A SP MCB [For FDA Control Panel][Make:- Havells/Legrand/BCH] [Approved by EIC] 360 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works(d) 240 mm x 200 mm x 65 mm 361 Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required(e) 240 mm x 200 mm x 65 mm 362 Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required(e) 240 mm x 200 mm x 65 mm 363 Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. 364 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.(i)2.5sqmm 365 Supplying and Fixing of Junction boxes, Cable glands, Connector, Screws etc. fixing accessories for SITC of Detectors, MCP and modules. 366 Supply, Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC(Location:- at Electrical Room under Ground Floor Staircase)04 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and pressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -1A & 13B 367 Supply, fitting and fixing including all necessary arrangement for complete installation of wall mounted Water Purifier having storage capacity- Not less than 8L, RO+UF+TDS control +UV In-Tank+ Copper Water Purifire, Purification Production Rate -Not Less than 15 L/hr with 1 Year Warranty + 3 Years Exteded Service Free (including all taxes, Mraket Rate) [Make-Kent/ Aquaguard/LG/Equivalent]
Contract Date: Jan 15, 2026 Contract Value : 62.61 Lakh
Local Bodies No of Bidders 3
West Bengal View Result →
13.
Educational and Research Institute #7822828 AOC
Notice Inviting E-Tender For Procurement Of Equipment, Instrument, Machineries, Tools Glassware, Etc. For Sheikhpara A.R.M. Polytechnic. , Jaw Crusher : Utilities Required : •Electric Supply : Single Phase, 220 V Ac, 3 Kw. •Set Of Sieves With Sieve Shaker For Analysis. •Floor Area 1.5 X 1M Technical Details : •Jaw : Size 100 X 150Mm. •Feed Hopper: Suitable Capacity. •Feed Size : 50Mm ( Approx. ) •Product Discharge Size : 5Mm To 15Mm. •Drive : Electric Motor, 3 Hp, Single Phase, •Control Panel Comprises Of : •Energy Measurement: Electronic Energy Meter. •Starter: 3 Hp, Single Phase. • Mcb: For Overload Protection. • Instruction Manual : An English Instruction Manual Will Be Provided Along With The Apparatus •The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Filter Press: Utilities Required: •Electric Supply: Single Phase, 220 V Ac, 1.5 Kw. •Water Supply. •Drain. •Slurry Required To Performing Experiment. Technical Details: •No. Of Frame : 6 •No. Of Plates : 7 •Size: 200 Mm X 200 Mm. •Material : Acrylic •Screw Jack Arrangement For Tightening And Removing Of Frames Easily. •Filter Medium : Filter Cloth •Filtrate Collection Tray: Material Stainless Steel, Suitable Size. •Slurry Feed Tank : Material Stainless Steel, Capacity 40 Ltrs. •Slurry Tank Agitator : Stainless Steel Impeller With Ss Shaft Coupled To Fhp Motor And Reduction Gear Box •Slurry Feed Pump : Gear Pump With Fhp Motor. •Piping System: Gi And Pvc. •Filtration Rate Measurement: Using Measuring Tank. Material Stainless Steel Pressure Measurement: Bourdon Type Pressure Gauge. •Overhead Water Tank: Material Stainless Steel, Capacity 25 Ltrs. •Control Panel Comprises Of Standard Make On / Off Switch, Mains Indicator Etc. •Instruction Manual : An English Instruction Manual Will Be Provided Along With The Apparatus •A Good Quality Painted Rigid Ms Structure Is Provided To Support All The Parts Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Ball Mill With Three Prefixed Speeds: Experimentation: • To Study Effect Of Rpm On The Power Consumption Of A Ball Mill. •To Determine The Efficiency Of A Ball Mill For Grinding A Material Of Known Wi. Utility Required : •Raw Material For Feed. •Electric Supply : Single Phase, 220 V Ac, 1 Kw. •Set Of Sieves With Sieve Shaker For Analysis. •Floor Area 1.5 X 1M •Steel Balls Technical Details : •Ball Mill : Material Ms •Dia 275Mm, Length 350Mm. Thickness 5 Mm. •Discharge Chute : Suitable Size. •Feed Size : 6 Mm ( Approx ) . •Product Size : 200 Mesh ( Approx. ) •Drive : 1 H.P. Motor Coupled To Reduction Gearbox & 3 Step Pulley •Revolution Counter : Mechanical Type. •Product Receiver : Material Stainless Steel Of Suitable Size. •Control Panel Comprises Of : •Energy Measurement : Electronic Energy Meter. •Mcb : For Overload Protection. •Standard Make On / Off Switch, Mains Indicator Etc. •Instruction Manual : An English Instruction Manual Will Be Provided Along With The Apparatus. •The Set-Up Is Fitted With Required Guards. •The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: • Standard Make On / Off Switch, Mains Indicator Etc. , Motorized Sieve Shaker Machine With Sieve : •Type : Vibratory Sieve Shaker For Dry Sieving Material In The Range 4.75Mm–20?M. • Sieve Diameter : 20Cm • Number Of Sieves : Minimum 8 Sieves Of Depth 5Cm Approx. • Power Supply: Suitable For Operating On 220 V, 50 Hz, Single Phase, Ac Supply • Arrangement Forchanging The Vibration Level Is Provided. • A Digital Timer Adjustable From 0-99 Minutes • 200Mm Sieve, Material: Brass, Full Height: 50Mm • Is: 45?M, 63?M, 90?M, 125?M, 180?M, 355?M, 500?M, 1.00Mm, 1.40Mm, 2.00Mm, 2.80Mm, 4.00Mm, 5.60Mm, 8.00Mm, 11.20Mm, 14.00Mm, 20.00Mm, Sieve Cover, • Sieve Pan. , Rotary Vacuum Filterexperimentation: •To Study The Performance Of A Rotary Vacuum Filter. •To Study The Operation Of Rotary Vacuum Filter Under Vacuum. •To Determine The Specific Cake Resistance And Medium Resistance. Utilities Required: •Electric Supply: Single Phase, 220 V Ac, 3.5 Kw. •Water Supply. •Drain. •Slurry Required To Performing Experiment. Technical Details: •Filter Drum : Material Stainless Steel, Dia. 250 Mm, Length 350 Mm. •Mesh : Material Stainless Steel •Filter : Canvas Cloth •No. Of Zones : 6 Nos. •Drive For Drum : Fhp Motor Coupled To A Reduction Gear Box •Trough : Material Stainless Steel, Compatible Capacity. •Trough Agitator : Material Stainless Steel, Driven By Fhp Motor With Reduction Gearbox. • Slurry Tank : Stainless Steel, Capacity 75 Ltrs. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Vacuum Filtration Unit:With Vacuum Trap Kit Capacity: 1000Ml Manifold Slurry Handling Equipped With Oil Free Vacuum Pump, R Is A Piston Powered And Oil Free Vacuum Pump. Max. Power : 80W, Vacuum -750 Mm / Hg It Contains A Moisture Trap / Vacuum Regulator. With Light Weight Is Not Only Suitable For Liquid Filtration But Also Perfect For Stack Or Ambient Gas Sampling. Filtration Funnel With Clamp : 250-300Ml, Non Toxic, Unbreakable Polysulfone Funnel Is Used In Microbial And Particulate Analysis. Aluminium Clamp Allows One Handed Operation. Funnels Do Not Leak After Repeated Autoclaving, ( 1, 3, 6 Nos. ) Vacuum Manifold Ss-304 / Ptfe Designed With Three Vacuum Outlets Each With Leak Proof Two Way Valve And A Vent Port , Ro Top Sieve Shaker Utilities Required : •Electric Supply: Single Phase, 220 V Ac, 50 Hz, 5-15 Amp Combined Socket With Earth Connection. Earth Voltage Should Be Less Than 5 Volts. •Material For Analysis. •Floor Area: 1 M X 1 M. •Electronic Weighing Balance: Capacity 2 Kg ( Least Count 1 Gm ) Technical Details : •Sieve Assembly : Compatible To Sievesof 20-Cm Dia. ( For 6-7 Sieves ) •Drive : By ½ Hp Motor •Control Panel Comprises Of : Standard Make On Off Switch, Mains Indicator Etc. •Special Arrangement For Setting Time For Shaking. •An English Instruction Manual Consisting Of Experimental Procedures, Block Diagram Etc. Will Be Provided Along With The Apparatus T •The Whole Set-Up Is Well Designed And Arranged On A Rigid Structure Painted With Industrial Pu Paint. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Sigma Mixer: • Capacity – 5Kg Per Batch Or 20 Kg Per Hour Approx. • Contact Parts Stainless Steel 304 Grade. • Blades Are Sigma Shape Type. • Motor – 2Hp With Gear Box. • Tilting Type Discharge. • Voltage 415 Volts Ac 3 Phase. , Centrifugal Pump Test Rig Apparatus ( With Three Prefixed Speeds ) Required For Operation: •Water Supply. •Drain. •Electricity 1 Kw, 220V Ac, Single Phase. •Floor Area 2 X 1 M. •Tachometer To Measure Rpm Technical Specifications: •Pump : Kirlosker Make, Capacity 1 Hp Speed 2800 Rpm ( Max. ) Head 12 M ( Max. ) •Medium Flow : Clear Water •Drive : 1 Hp Crompton / Ge Make Motor Having Step Cone Pulley For Three Different Speeds. •Sump Tank : Capacity 110 Ltrs. •Flow Measurement: Using Measuring Tank With Piezometer, Capacity 70 Ltrs. •Stop Watch: Electronic. •Pressure Gauge: Bourdon Type. •The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: •Measurement: Electronic Energy Meter, L&T Make. •Mcb: For Overload Protection. •Energy Standard Make On / Off Switch, Mains Indicator, Etc. , Pipe Friction Apparatus Requirment For Operation: •Water Supply. •Drain. •Electricity 0.5 Kw, 220V Ac, Single Phase. •Floor Area 1.5 X 0.75 M. Technical Specification: •Pipe Test Section: ( I ) Dia ½”, Length : 1M, Material G.I. ( Ii ) Dia ¾”, Length: 1.25M, Material G.I. •Water Circulation: Fhp Pump, Crompton / Godrej / G.E Makes. •Flow Measurement: Using Measuring Tank With Piezometer, Capacity 25 Ltrs. •Sump Tank: Capacity 50 Ltrs. •Stop Watch: Electronic. •Control Panel Comprises Of : • Standard Make On / Off Switch, Mains Indicator, Etc. •Instruction Manual : An English Instruction Manual Will Be Provided Along With The Apparatus Tanks Will Be Made Of Stainless Steel. •The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Orifice Meter Requirment For Operation: •Water Supply ( Initial Fill ) . •Floor Drain Required. •Floor Area Required: 1.5 X 0.75 M. •Mercury ( Hg ) For Manometer ( 250 Gm ) . Technical Specification: • Orifice Meter : Orifice Plate Made Of Stainless Steel And Housing Made Of Clear • Acrylic Compatible To 1” Dia. Pipe. • Water Circulation: Fhp Pump, Crompton Make. • Flow Measurement: Using Measuring Tank With Piezometer ( Capacity 25 Ltrs. ) And Electronic Stop Watch • Sump Tank: Capacity 50 Ltrs. • Instruction Manual: An English Instruction Manual Will Be Provided Along With The Apparatus Tanks Will Be Made Of Stainless Steel. • The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. • Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Rotameterrequirment For Operation: •Electricity Supply: Single Phase, 220 V Ac, 50 Hz, 5-15 Amp Combined Socket With Earth Connection. •Water Supply ( Initial Fill ) . •Floor Drain Required. •Floor Area Required: 1.5 M X 0.75 M. Technical Specification: •Rotameter: Compatible Range. •Water Circulation: Fhp Pump, Crompton Makes. •Flow Measurement: Using Measuring Tank S.S ( 304 Grade ) ( Capacity 25 Ltrs. ) And Electronic Stop Watch. •Sump Tank: S.S ( 304 Grade ) Capacity 50 Ltrs . •Control Panel Comprises Of: Standard Makes On / Off Switch, Mains Indicator, Etc. •Instruction Manual: An English Instruction Manual Will Be Provided Along With The Apparatus. •Tanks Will Be Made Of Stainless Steel. • The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Venturimeterrequirment For Operation: •Water Supply ( Initial Fill ) . •Floor Drain Required. •Floor Area Required: 1.5 X 0.75 M. Technical Specification: •Venturimeter: Material Clear Acrylic Compatible To 1” Dia. Pipe. Pressure Measurement: Differential Pressure Manometer. • Water Circulation: 0.5 Hp Pump, Crompton / Kirloskar Make. • Flow Measurement: : Measuring Tank Material: Stainless Steel, 304 Grade, 1.2 Mm Thick With Piezometer, Capacity: 25 Ltr, Measuring Tank With Piezometer ( Capacity 25 Ltrs. ) And Electronic Stop Watch • Sump Tank: : Material: Stainless Steel 304 Grade, 1.2 Mm Thick , Capacity: 50 Ltr. • All Ball Valves Operating Temperature Range: -400F To 3020 F. • Valves Working Pressure: In Range Of 600Psi, Vacuum Pressure Up To 2×10-5Psi. • Instruction Manual: An English Instruction Manual Will Be Provided Along With The Apparatus Tanks Will Be Made Of Stainless Steel. • The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Reynolds Apparatus Requirment For Operation: •Electricity Supply: Single Phase 220 V Ac, 50Hz, 5-15 Amp Combined Socket With Earth Connection. • Water Supply ( Initial Fill ) . • Floor Drain Required. • Floor Area Required: 1.5 M X 0.75 M Technical Specification: •Chemical Required: Dye ( Kmno4 ) - 10 Gm •Tube : Material Borosilicate Glass •Dye Vessel : Material Stainless Steel, Suitable Capacity •Capillary Tube: Material Copper / Stainless Steel. •Constant Head Water Tank: Capacity 40 Ltrs. •Water Circulation: Fhp Pump, Champion / Godrej Makes. •Flow Measurement: Using Measuring Cylinder. •Sump Tank: Capacity 60 Ltrs. •Stop Watch: Electronic. •Control Panel Comprises Of : •Standard Make On / Off Switch, Mains Indicator, Etc. •Instruction Manual : An English Instruction Manual Will Be Provided Along •With The Apparatus Tanks Will Be Made Of Stainless Steel. •The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Shell & Tube Heat Exchanger Requirment For Operation: •Water Supply 20 Lit / Min ( Approx. ) And Drain. •Electricity Supply: 1 Phase, 220 V Ac, 4 Kw. •Floor Area Of 1.5 M X 0.75 M. Technical Specification: •System: Water To Water. ( 1 – 2 Shell & Tube Type ) •Shell. : Material Stainless Steel. Insulated With Ceramic Wool And Cladded With Aluminum Foil. Dia. 220 Mm, Length 500 Mm ( Approx. ) 25% Cut Baffles At 100 Mm Distance 4 Nos. •Tube: Od 16Mm Approx., Length 500Mm ( 24 Nos. ) •Water Flow Measurement: Rota Meters ( 2Nos. ) One Each For Cold & Hot Fluid. •Hot Water Tank: Made Of Stainless Steel Insulated With Ceramic Fibre Wool. •Hot Water Circulation : Magnetic Pump •Heaters: Nichrome Wire Heater ( 2 Nos. ) •Control Panel Comprising Of: Digital Temp. Controller: 0-199.90C, ( For Hot Water Tank ) Digital Temp. Indicator: 0-199.90C, With Multi-Channel Switch •Temperature Sensors: Rtd Pt-100 Type. •With Standard Make On / Off Switch, Mains Indicator Etc. •Instruction Manual : An English Instruction Manual Will Be Provided Along With The Apparatus •A Good Quality Painted Rigid Ms Structure Is Provided To Support All The Parts. Control Panel: Standard Make On / Off Switch, Mains Indicator Etc. , Turbidity Meter:Turbidity Meter.Ntu ( Nephelometric Turbidity Unit ) Measuring Unit. Wide And Auto Measurement Range: 0-1000 Ntu. High Resolution: 0.01 Ntu / 1 Ntu. Four Operation Buttons And Three Calibration Points, Easy Operation. Range: 0.00-50.00 Ntu, 50-1, 000 Ntu.Auto Ranging And Data Hold. , Waterproof Large Screen Display Pocket Tester For Ph / Tds / Conductivity / Salinity / Temp: Temp. Display=0-50.0°C / 32.0-122.0°F Temp. Resolution / Accuracy=0.1°C / °F :0.5 C° / 0.9 F° Supply With Calibration Solutions: 1.Ph Buffer Solutions Ph 4.01 Buffer Ph 7.00 Buffer Ph 10.01 Buffer 2.Tds Calibration Solutions ( 480 Ml ) 50 Ppm, 300 Ppm, 1000 Ppm 3.Conductivity Calibration Solutions ( 4 8 0 Ml ) 100 Ms Kcl, 1413 Ms Kcl, 2764 Ms Kcl 4. Salinity Calibration Solution 5 Ppt*Nacl Calibration Solution , Kjeldhal Distillation:Kjeldahl Distillation •Kjeldahl Distillation Systems For Highly Reproducible Results For Nitrogen Estimation By Kjeldahl Method •Borosilicate Glass Assembly Along With The Ss Steam Generator •Process Kill Switch To Halt The Process In Case Of Accidental Door Opening •Detachable Bottom Drip Tray For Extra Protection Against Acid Attack •Single Encoder Push Button To Control All Automatic Functions •Anytime Alkali Addition During The Distillation Cycle •Tube Sensor That Enables Safe Operating Conditions In Event Of Tube Damage •Reagent Refill Level Sensor To Avert Reagent Dry Out. Specification :- •Steam Addition : Automatic •Maximum Distillation Time ( Mins ) •Current Consumption : 5.5 A •Distilled Water Addition : Manual , Digital Do Meter: Dissolved Oxygen Analyser Cum Temperature Indicator Along With Speed Regulated Stirrer. Gold / Silver Do Probe, Rtd Temperature Sensor. ( Table Model ) Specification:- Do Range : 0 To 20 Ppm Do Temperature : 0 To 60°C Do Resolutions : 0.1 Ppm Do Resolutions : 0.1°C , Hardness Tester : Tablet Hardness Tester ( Monsanto Type ) Is A Fairly Handy Instrument For Taking Quick Readings For The Hardness Of Tablets. This Tablet Hardness Tester ( Monsanto Type ) Is Made Of Brass Turned Parts, Heavily Chrome Plated, The Scale Is 0 To 20Kg And The Index Mark And Division Is In 1Kg Reading. Scale Adjustable For Zero Setting As Per Size Of The Tablets. , Conductivity Meter : Deluxe Conductivity Meter Using Latest Microcontroller, Auto Ranging ( 6 Ranges From 20?S To 1000Ms ) , Auto Temperature Compensation, Auto Cell Constant Measurement, Touch Keys Along With Conductivity Cell Of 0.1 Cell Constant And Temperature Probe. ( Table Model ) , Muffle Furnace : Our Muffle Furnace Finds Application In Various Laboratories And Research Facilities To Test The Characteristics Of Materials At Extremely High And Accurate Temperatures. Compactly Designed, And Has A Sturdy Construction For Long Term Use. Insulation Is Provided With Ceramic Fiber Wool. The Working Temperature Is 1150°C, With The Maximum Temperature Being 1200°C. The Furnace Is Fitted With A Dual Display Microprocessor Pid Digital Temperature Indicator Cum Controller, Ci / Al Thermocouple. Heating Elements Are Made Up Of Kanthal Wire. It Is Workable On 220 V Ac 50 Hz Triple Phase. Inner Muffle Size : 300 X 150 X 150Mm , Automatic Karl Fisher Titrator : Microprocessor K.F Moisture Titrator With Built-In Magnetic Stirrer, Auto Computation Of Moisture In Ppm, %Age And Mg Of Water. Storage Of Date, Time Batch No. & Final Results Of 20 Titrations. K.F. Reagent Dispensing By Motorized Process. Final Results Are Flashed On 8 Digit Digital Display , Soxhlet Apparatus : Soxhlet Apparatus With Six Chamber Mantle Type, Flask Capacity 250 Ml, 2 Vertical, 2 Horizontal Rods With Adaptor And Screw To Hold Flask , Six Test Heater Of High Quality Nicrom Wire With Cotton Cover Including Soxhlet Apparatus Glass Parts, Rb Flask Of 250Ml, Extractor, Condenser, Silicon Tube, Thimble ( 4 Packet ) . , Thin Layer Chromatography Kit : This Unit Is Based On Desaga German Pattern Developed By Dr. Stahl Having Movable Applicator With Inbuilt Thickness Adjustment Arrangement Between 0 To Movable 2 Mm. With The Following Components. Spreader ( Applicator ) Made Of Electroplated Brass. Perspex Base Size 114X23 Cm. To Support 5 Glass Plates Of Size: 20X20 Cm. Or 10 Of 20X10 Cm. And Two Plates Of 20X5 Cm. Drying Plate Rack Anodised Aluminum For Ten 20 X 20 Cm. Plates. Spotting Template Perspex. Developing Tank With Lid. Five Glass Plates 20 X 20 Cm. And Two End Plates 20 X 5 Cm. Or Ten 20 X 10 And Two 20 X 5 Cm Plates. Micro Pipette Coming Glass. Scriber. Glass Sprayer With Rubber Bellow. Spares : A. Chromatography Tank ( Tlc Chamber ) With Cover For 20 X 20 Cm. Plates. B. Chromatography Tank ( Tlc Chamber ) With Cover For 20 X 10 Cm. Plates. C. Chromatography Tank ( Tlc Chamber ) With Cover For 20 X 5 Cm. Plates. Iii. Tlc Glass Plates All Side Ground : A. 20 X 20 Cm. B.20 X 10 Cm. C. 20 X 5 Cm. Iv. Spreader For Tlc : A. Brass B. Aluminium , Paper Chromatography Kit Compact Chromatography Cabinets Are Useful For Lab. It Is Joint Less Bakelite Molding Supplied With Its Accessories W To Conduct The Practical And To Evaluate Rf Values. The Standard Setup Consists Of Bakelite Cabinet With Lid, With Front Sliding Glass, Ss Pot, Hanger To Hang Chromatography Paper Stand, Glass Sprayer With Rubber Below, Supplied With 1Pkt. Of 25 Chromatography Shttes Of Size 18X10cm , Uv – Vis Spectrophotometer ( Double Beam ) Wavelength Range : 190-1100Nm Spectral Bandwidth : 1 Nm Optical System : Double Beam, Blazed Holographic Grating ( 1200 Lines / Mm ) Wavelength Accuracy : ±0.5Nm Wavelength Repeatability : =0.2Nm , Colorimeter :Digital Photo Colorimeter 8 Filters, Mains Operated Using Latest Microcontroller, With 2½ Digit Led Display, Sample Size 1Ml. Auto Zero Using Touch Keys. , Tintometer: Applicable Scale : Rybn, Ry, Ry10:1, Aocs Tintometer® Ry, Chlorophyll & Beta-Carotene Scale Applicable Standard : Aocs Cc 8D-55; Aocs Cc 13B-45; Aocs Cc 13D-55; Aocs Cc 13E-92; Aocs Cc 13J-97; Bs684; Bs684 Section 2.20; Chinese Gb / T 22460-2008; Is 548 ( Part 1 ) -2010; Iso 15305; Iso 27608; Ms 252 : Part 16; Ms 817 : Part 12 Integrated Cell Heater : Yes Removable Cell Chamber : Yes Colour Type : Transparent Wavelength Range : 380 - 780 Nm Wavelength Accuracy : 0.2 Nm Spectral Scope : < 15 Nm Photometric Range : 0 - 100 % T Photometric Linearity : ± 0.01 % T Repeatability : ± 0.5 % T Stray Light : < 0.01 % T Detector : Spectrometer Interfaces : Usb; Rs 232 Instrument Housing : Aluminium Portability : Benchtop Display : Lcd Input Voltage : 110 Vac, 250 Vac, 60 W ( 24 V ) Environmental Conditions : Temperature: +5°C - 40°C ; Humidity: Up To 90 % Non Condensing Stock Conditions : Temperature: -20°C - 85°C ; Humidity: Up To 90 % Non Condensing Compliance : Ce Languages User Interface : English, German, French, Spanish, Italian, Portuguese, Russian, Japanese, Chinese Supply Includes : Instrument With External Power Supply; Set Of 3 Power Leads ( Uk, European And United States ) ; Quick Start Guide ( Hard Copy ) ; Usb Memory Stick ( Containing The Manuals ) ; Certificate Of Conformity; Conformance Filter; Cell ( Borosilicate, 1 Path Length ) ; Cell ( Borosilicate, 5¼” Path Length ) , Gas Cylinder With Commercial Oven Containingsingleburner , Meat Mincer Grinder:Power 3 Hp Capacity 500 Kg Per Hour Usage / Application Commercial Voltage 110 – 220 V Frequency 50 Hz Weight 200 Kg Country Of Origin Made In India. , Sausage Filling Machine ( Manual ) Vertical Type Capacity : 3L Dimension : 300*300*550Mm Gross Weight : 13Kg , Full-Automatic Meat Smoke Oven With 1M Chimney Capacity : 250Kg. Power ( Kw ) : 11.32 Lp / Hp Temperature : 110ºc Lp Steam Pressure : 0.1-0.2Mpa Hp Steam Pressure : 0.3-0.6Mpa Smoke Ignition Time : 15Min , Edible Oil Extraction Plant : Oil Expeller 5 Bolt, Modern Design, With Round Kettle Bearing System Gear Box Single Gear Fabricated Hobbing Cut Gear Oil Collection Tray , Taps Spanner, Pipes. Etc With Ms Fabricated Base Frame Complete With All Accessories With 5 Hp 3 Phase Electric Motor Crushing Capacity 25-30 Kg / Hour Filter Press 12 X 12 X 12 Plate Filter Nut-12, Cock-12 Spennar Set 1 Set Filter Cloth , Oil Feeding Pump 20Mm Non Return Valve = 2 Pcs Foot Valve-1 Pcs , Oil Collection Tray Pipeline And Fitting Accessories Production Capacity 50-60 Leter / Hour All Type Edible Oil Can Filter Weight :- 250 Kg 10 Liter Storage Tank Total Required Space :- 6 Ft X 6 Ft Total Weight :- 600 Kg , Wet Grinder Tilting Capacity 5 Liters. Tilting Type. Contact Parts Of S. Stone Grinding Process. W I T H Less Heating To Protect The Flavor Of Food Products I.E. Dal, Rice Etc. Drive By 0.5Hp Or 1Hp Motor, 220 Votls Ac Operated. , Soda Water / Carbonated Soft Drinks Plant Semiautomatic Soda Water Pet Bottle Filling Set Up 1. Water Chilling Unit 300 Ltr Capacity 2. Automatic Carbontor With Ss Pump Auto Cut Water Level System Co2 Gas Controller 3. Soda Water 2 Head Semiautomatic Filler With Hand Operated Lever Pneumaticclly Operated Bottle To Be Fill 200Ml To 500Ml All Body Made Of Ss Output 450 Bph 4. 1 Head Pneumatically Glass Bottle Capper 5. 2 Head Pet Bottle Washer 6. Line Charges Carbonator To Filler 7. Air Compressor With Autocut System For Filler Use 8. Reverse Osmosis Plant 250Lph Capacity With Ss Stand Membrance Microne Filters Dosing Pump Raw Water Pump High Pressure Pump Etc , Milling Machine ( Food Grinder Machine ) Capacity / Hr.: 8- 10 Kg. Coarse - 18Kg. Motor: 1.5 Hp, 220V Single Phase Moc: Structural Parts Are Ms & All Cantact Parts Are S 304 , Ss Pulvariser2 Hp Motor Chamber Size : 6X3 Inch Table Top Laboratory Capacity / Hr.: 5-10 Kg. Motor: 1 Hp, 220V Single Phase Moc: S 304 , Rotary Rack Oven ( Electric Heated ) : Tray Capacity : 12 ( 12*18 ) Fuel Average : ( Diesel ) : 0.5 Ltr Approx Dimension ( L X Wx H ) : 60X42X74 Total Power Load : 1.5 Hp Approx Baking Area : 2160 Sq. In Production Capacity : 11 Kg Biscuit / Hr Approx 22 Pcs Bread ( 400 Gm ) / 25 Min Approx , Deck Oven : 3 Deck 6 Tray Gas Deck Oven Capacity : 250 Per Batch Operation Type : Automatic Power Source : Gas Number Of Decks : Double Body Material : Stainless Steel Certification : Iso Voltage : 220 V Weight : 190Kg. ( Approx ) , Candy Making Machine Hand Operated Capacity: 1-5 Kg Material Of Contraction Must Be Food Grade Material , Micro Pipette: Single Channel Fixed Vol Pipette , Calibration & Accuracy As Per Iso 8655 Volume Range ( ?L ) : 0-10 ?L , Haemocytometer In Box With Counting Chamber, Cover Glasses Pair, Rbc And Wbc Pipettes With Rubber Suction Tubing And Mouth Piece. , Digital Electronic Balance Capacity : 220Gm Readability : 0.001Gm , Air Conditioner For Sensitive Lab Equipments / Microbiology Lab & Microbio Technology Labcapacity: 1.5 Ton, Rating: 5 Star With Inveter, Any Standard Brand , Small Gas System : 5Kg Gas Cylinder With Accessories , Hydrometer Triple Scale: 3Pcs. Brix: 0-30 ( 3Pcs ) . Sp. Gravity : 3Pcs , Alcohol Distillationunit 1.Capacity 1000 Ml 2.Made Of Borosilicate Glass 3.Ideal For Distilling Alcohol In The Laboratory To Produce The Purest Grade 4.Thorpes Revenue Still For Purification Of Ethyl Alcohol , Pycnometer Bottles : Specific Gravity Bottles ( Pyknometer ) With Thermometer And Capillary Side Tube Capacity : 25Ml Specific Gravity Bottles ( Pyknometer ) With Thermometer And Capillary Side Tube Capacity : 50Ml , Deionizer : Features • Unique Digital Conductivity Meter Fitted With Unit. • In-Built Pre Filter. • Upflow Treatment. • Can Be Connected Direct To Water Tap. • Treated Water Will Have The Conductivity Less Than 10 Ms / Cm And Ph Of 7.5 -9. • Non Corrosive Regeneration Tank. • High Capacity Cation & Anion Exchange Resins. • Easy Portable - Metal Stand And Trolley. • Simple Periodic Regeneration - Negligible Operating Costs. • Output / Hr ( Ltrs ) : 50 , Water Distillation Apparatus- Stainless Steel Capacity 10 Ltr Per Hour With 3 Heating Element Total Load Capacity-3 Kw Table Top Model , Slab For Instruments : Dimension: 12 X2.5X 3.5 ( Lx W Xh ) , Moc: Bricks With Marble Top , Sink : Dimension: 2 X1.5 ( L Xw ) Moc: Ss , Notice Board For Fpt Dept. Size : 2X2x2 Feet. Moc: Inside Velvet, Wooden Frame, Glass Cover , Laboratory Name Plate Dimension: 1 X10 ( Lxw ) Moc: Fiber , Department All Sign Board : Dimension: 3 X3 X6 ( Lx Wxt ) , Moc: Acrylic Sheet, Aluminiumframe , Ice Cream Plant: 1 ) Batch Pasteurizer : 01 No. Batch Pasteuriser Having Capacity 25 Ltrs Fabricated Out Of 2 Mm Thick S.S.304 Quality Stainless Steel Material For Inner Tank And 2 Mm S S Intermediate Shell And 2 Mm Thick Outer Tank In S S With Glass Wool Insulation. Batch Pasteuriser Are Used For Pasteurization Of Milk With Smp And Stabilizer And Emulsion, Cream, Butter. The Pasteurization Temp. Of This Milk Will Be Around 65-70 Deg.C. Heating Arrangement For Ice Cream Mix One Small Lpg Gas Fired Boiler Are Attached With Batch Pasteuriser. 2 ) S.S. Milk Pump : 01 No. S. S. Milk Pump 0.5 Hp Operated On 415 Volts 3 Phase Sanitary Design Having Capacity Not Less Than 500 L.P.H. @ 10 Mwc Head. 3 ) S.S. Conical Inline Filter : 01 No. One S. S. Filter To Be Fitted Between Tank And Milk Pump. The Filter Is Having Fine And Coarse S. S. Mesh For Proper Filtration Of Milk. 4 ) Homogenizer: 01No. Capacity 25 Ltrs / Hrs. Design – Robust, Strudy And Self Supported. It Should Be Two Stage Designs. High Pressure Homogeniser With Hydraulically Two Stage Homogeniser Head Having Discharge Capacity 25 Lph At Working Pressure 150 Bar With 1 Hp Electric Motor Of 1440 Rpm, 415 V, 50 C / S V Belts Drive Arrangement With Frame And Ss Cabinet Enclosure All Contact Part Are Made Of Ss 316 Following Are The Accessories Supplied. Glysrine Filled Pressure Gauge 400 Kg / Cm 1 No. Ss Suction & Discharge Pipe With End Collection 1 Set. Tool Kit. 5 ) Aging Vat : 01No. Aging Vat Having Capacity 25 Ltrs Each Fabricated Out Of 2 Mm Thick S.S.304 Quality Stainless Steel Material For Inner Tank And 2 Mm S S Intermediate Shell And 2 Mm Thick Outer Tank In S S With Thermacole Insulation. Aging Tank Are Used For Preparation Of Ice Cream Mixes And Maintain The Temp. Of Ice Cream Mix Up To + 5 Deg.C. Tank Is Connected With Separate Glycole System To Cool Down The Ice Cream Mix. 6 ) Ss Pipes & Fittings : 01Lot One Lot Of S.S. Pipes And Fittings Confirming Ofs.M.S. Standard With Necessary Valve And S. S. Clamps To Interconnect All Milk And Cip Lines Based On Compact Layout. 7 ) Batch Freezer : 01No. Batch Freezer Having Capacity 5 Ltrs Of Ice Cream Per Batch In Around 30 Minutes. All Ss Part Connected With Ice Cream Mix Ss 316 Material. The Suitable Capacity Refrigeration System Connected To Freezer To Cool Down The Temp. Of Ice Cream From + 5 To Minus 5 Deg.C. Within 30 Minutes. The Refrigeration System Operates On R-22 Gas With Air Cooled Condenser. 8 ) S. S. Pipes And Fittings: 01 Lot One Lot Of S.S. Pipes And Fittings Confirming Of S.M.S. Standard With Necessary Valve And S. S. Clamps To Interconnect All Milk And Cip Lines Based On Compact Layout. 09. Batch Freezer: 01 No. Batch Freezer Having Capacity 5 Ltrs Of Ice Cream Per Batch In Around 30 Minutes. All Ss Part Connected With Ice Cream Mix Ss 316 Material. The Suitable Capacity Refrigeration System Connected To Freezer To Cool Down The Temp. Of Ice Cream From + 5 To Minus 5 Deg.C. Within 30 Minutes. The Refrigeration System Operates On R-22 Gas With Air Cooled Condenser. Air Pump Is Also Connected With Batch Freezer. 10. Hardner Cum Deep Freezer:01 No. 100 Ltrs Capacity Deep Freezer Which Is Required For Hardening & Storing Of Ice Cream. The Deep Freezer Is Operated At Minus 20 Deg. C. With Sealed Compressor, Air Cooled Condensing Unit . 11. Ice Candy Machine: 01 No. Bar Ice Cream Candy Lolly Tank With Aisi Ss316 Product Contact :2 Moduls. It Would Be Fitted With Stick Holder To Make The Ice Candies. It Will Be Fitted With Suitable Refrigeration System ( Glycole ) . 12. Flavour Tank: 01 No. This Tank Will Be Made From Aisi Ss316 Will Used To Add The Required Flavour In The Mix. This Will Be Fitted In The Suction Line Of The Centrifuge Pump With Valve. Both The Flavour And Mix Will Be Pumped At A Time So That The Flavour Mixes With The Ice Cream Mix. 13. M. C. C. Control Pannel: 01 No. One Mcc Control Panel With All Necessary Star- Delta, D.O.L. Starter, Push Buttons Indicating Lamps, And Interlocking. 14. Power Earthing & Control Cable : 01 Lot. One Lot Of Power Earthing & Control Cable To Connect All Electric Motors To Mcc Control Panel. 15.Structural And Supports:01 Lot. One Lot Of M. S. Channel, Angle And Pipes Required For Support Foundation Frames And Necessary Fabrication Work , Evaporator : Vaccum Evaporator For Lab Model With A Feed Rate Of 50Kgs / Hr Technical Specification Feed Rate - 50 Lph Vacuum Vaporator Capacity: 50 Lt / H, Made Of Aisi 304 Quality Stainless Steel. With Platform The Water In The Milk Is Evaporated By The Circulation System Of The Machine. At The Same Time, This Machine Detects Bad Odors In The Milk. Vacuum Effect: 12 M3 / H, Cip Cleaning Ball, Level Indicator Glass, It Works With Steam At 3 Atu Pressure. Standard Capacity: Input 50 Lhp - Output 15 Lph ( 35 Water Decreasing Capacity ) Working Bar: Between 3-5 Vacuum Pump: Mazda , Vacuum Pressure 650 Mm-Hg, Monoblock Type. Inlet And Outlet Diameter: Dn 25, Steam Required 20 Kg / Hr Continuous Milk Process System Motor Power 5, 4 Kw Ac, 3 * 380 V, 50 Hz, Ip 55, Ie2 Condensate Heat Exchanger: Aisi 304 Stainless Steel, 500 Lt / H Capacity, Tubular. Vacuum Meter: The Measuring Range Is Between + - 0 / -70 Mbar. Control Panel: Aisi 304 Stainless Steel, Contactor, Platform: Aisi 304 Stainless Steel, Stainless Steel Profile, Adjustable Legs, All Connections On The Chassis Are Immobilized; The Entire System Is Completed On The Platform. Ts Increase From 8.5 Upto 28 And More , Khoya Making Machine ( Fully Ss ) : Khoya Making Machine ( Fully Ss ) Lab Scale, Semi-Automatic. Capacity / Hr : 20 - 100 Lph 220V Single Phase Moc: Structural Parts Are Ms &All Cantact Parts Are Ss 304 , Paneer Processing Plant ( Ppp-20 System ) , Capacity: 60 Kg / Day ( 8 Hr Operation ) : Scope Of Supply For Ppp-20 System Milk Heating System The Unit Consists Of An Non-Insulated Vessel, Capacity 40L, Moc Astm 304, For Coagulating 20L Milk @ 90-95 Degrees Celsius. There Is A 2Kw Element Attachment For Auto -Heat Generation As Per Standards. Complete With Pressure Relief Valve, Temperature Guage. The Bottom Discharge Butterfly Valve Is 38.1 Mm. Usual Time For Heating Is 10 Minutes. Milk Coagulation System The Bottom Part Consists Of A 25L Coagulation Vessel With A Perforated Filter Crate For Whey Separation. This Is A Wheeled Vessel That Can Be Moved To The Pressing Bench For Further Process. Paneer Boxes / Moulds : This Comprises A U Shaped Body, Two End Plates And A Top Plate.All Of The Components Are Of Stainless Steel And Are Perforated To Allow The Whey To Flow Out.It Is Made Up Of 4 Removable Pieces For Easy Cleaning. Size Of The Moulds In Inches ( L / B / H ) : 13 / 9 / 4 Paneer Press: It Consists Of Ms Top Frame And Stand, All Other Parts Like Shaft For Press, Handle, Drainage Tray Etc. Are Having Ss 304 Mocthis Will Be Used To Press Chhana To Get The Final Paneer Block Of 4-5 Kg. Manual Paneer Cutter: Single Press Cutter For Customized Size Will Be Provided From 200Gm To 1 Kg. Consists Of A Slotted Tray And The Cutter Press With 0.5 Mm Blades Tool Box: Comprehensive Tool Box With Electrical Diagrams And Electrical Spares: Operation Manual: A Detailed Manual Is Provided Containing The Operating And Maintenance Procedures. Three Copies Hard, One Soft Copy. Accessories :- Vacuum Sealing Unit Must Be Quoted – 1 No. , Ghee Making Machine Lab Scale, Semi-Automatic. Capacity: 5-20 Kg Impeller: 20-25 Rpm, Bottom Drain Valve 220V Single Phase Moc: Structural Parts Are Ms & All Cantact Parts Are Ss 304 , Horizontal Sealer Features :- 1 ) Useful For Easy Transportation & Storage. 2 ) Simple Usage With High Efficiency. 3 ) Low Energy Consumption & Labor Saving. 4 ) Protect Product From Dust, Moisture, Surface Damage & Pilferage. Specification :- Temp. Range : 0-300*C Power : 500W Sealing Speed : 0-12Mtr / Min. Sealing Width : 8-10Mm , Gas Cylinder With Commercial Oven Containing Single Burner , Digital Electronic Balance : Electronic Precision Balance Capacity : 220Gm Readability : 0.0001Gm ( 0.1Mg ) Linearity : 0.4Mg Pan Size : 80 Mm , Lcr Q Meter Lcr Meter Features An Innovative Automatic Selection Technology, Automatically Measuring L, C And R With Q, D And T By Just Turn On The Meter. The Testing Frequency Is Up To 10Khz And It Can Output Up To 100Khz Test Frequency. It Provides High Accuracy With Four Or Five Terminal Kelvin Measurements. 4-1 / 2 Digits, Dual Lcd, Auto Lcr / Dcr / D / Q / Esr / Phase Angle, Variable Frequency Output Of 100Hz / 120Hz / 1Khz / 10Khz / 100Khz. , Hay, Sbridge Trainer Kit : Inductance Measurement Range: 50Mh To 150Mh Product Description Hays Bridge Trainer Is Used To Design Hay’S Bridge, Which Determines The Value Of Unknown Inductors ( L ) . The Students Can Balance The Bridge Either By Observing Waveform On Cro Or By Using The Built In Speaker. This Kit Has Been Designed Keeping Students In Mind So Its Very Easy To Understand And Use. Details:- Inductance Measurement Range: 50Mh To 150Mh. On Board Oscillator Section. On Board Circuit For Designing Hay’S Bridge On Board Amplifier Section On Board Unknown Inductors For Conducting The Experiment On Board Speaker Interface Test Points Are Provided To Analyse Signals At Various Points On / Off Switch And Led For Power Indication. Bare Board Tested Glass Epoxy Smobc Pcb Is Used. Block Description Screen Printed On Glassy Epoxy Pcb All Interconnections Are Made Using 2Mm Banana Patch Cords Supplied With User Manual And Patch Cords With Built-In Power Supply Enclosed In A Wooden / Plastic Box , Anderson’S Bridge Trainer Kit : This Is Useful For Students To Determination Of Self Inductance Of A Coil By Anderson’S Bridge. Features • Stand Alone System • Inbuilt Audio Frequency Generator • In-Built Stable 3.5 Character Digital Meters • 0-20 V Variable Power Supply •Easy To Learn And Illustrative Study Materials • Attractive , Durable And Insulating Wooden Casing. Technical Specifications On Board Dc Power Supply : +12V Dc Ammeter Range : 1?A To 200Ma Display : 3½ Digit , Desauti Bridge Trainer Bridge Features • Stand Alone System • In-Built Stable 3.5 Character Digital Meters • 0-20 V Variable Power Supply •Easy To Learn And Illustrative Study Materials • Attractive, Durable And Insulating Wooden Casing. Technical Specifications On Board Dc Power Supply : +12V Dc Ammeter Range : 1?A To 200Ma Display : 3½ Digit Voltmeter Range : 1Mv To 200V Display : 3½ Digit Mains Power : 230V Ac ±10% , Wien’Sbridge Trainer Kit : Frequency Measurement Range: 10Hz To 10Khz , Display Counter : Should Be Provided With The Facility To Count 6 Digit On Digital Display ( Led / Lcd ) With Maximum Count Of 999999 , Cardiac Pacemaker : Int.- Ext. Pacemaker Internal – External Pacemaker Demo. Type Trainer Internal – External Pacemaker Is External Dives To Stimulate Heart. Two Mode Fixed Mode And Demand Modes. Toggle Switch For To Select The Mode. Rate Control Knob To Adjust Heart Rate Pulse Rate 30 To 150 Bpm±. Positive Pulse Duration Of Pulse Wave 2Ms.± ( Fix Or Adjustable ) , Out Put Intensity 0 To 9V Adjustable. Input Ecg Sync Pulse 9V±. Disc Electrodes. Audible & Visible Indication For Each Pulse. Test Points On The Top Of Instrument Through 2Mm Socket. Power Supply 230V, 50Hz. Dimensions 250 X 75 X 250 Mm± Study On Skrip Int.- Ext. Pacemaker Study Of Pacemaker Working. Study & Need Of Mode Internal External. Study Of Placement Of Electrodes. Study Of Demand & Fixed Mode. Study Of Signal Processing, Working Of Each Block & Etc , Patient Monitor : Should Be Provided With The Facility To Monitor Real Time Ecg, Noninvasive Blood Pressure, Spo2, Respiration Rate And Temperature Parameters For Adult, Pediatric And Neonatal Monitoring Along With Necessary Accessories. , Dc Defibrillator : Defibrillator Using Microcontroller Defibrillator Using Microcontroller Trainer This Is Demo Type Instrument. Three Is Instant And Sync Modes, Joules & Threshold Control. Low Output Voltage. Output Connects To Dso. Ecg Input Sync Pulse. Input Ep Stereo Banana Socket Indication Armed, Sync & Inst, Charging & Discharging With Audio Indications 16X2 Lcd Display, Set, Up, Down, Enter Key. Charge Key Up & Down Output Ep Stereo & 4Mm Socket, 100Mm Paddle Disc Electrodes With Switch Test Point In The Front Panel Of Instrument Through 2Mm Socket. Supply 230V / 50Hz, Dimension 150 X 150 X 250Mm±, Standard Accessories , Ventilator : Bipap Non Invasive Machine Trainer The Bipap Machine Comes With A Face Mask Or A Nasal Mask, A Motor, A Tube That Connects The Motor To The Mask And A Humidifier. Bipap With Humidifier Prevents Issues Like Dry Mouth, Dry Throat, Cracked Lips, Nosebleeds, Chest Pain, And Nasal Infections. The Machines Motor Blows Pressurised Air Through The Tube And The Air Enters Your Lungs Through The Mask. This Expands The Size Of Your Lungs, Resulting In A More Effortless Inhalation Of Oxygen And Exhalation Of Carbon Dioxide. It Is Important To Carefully Follow Your Doctors Instructions On How And When To Use The Bipap Machine To Achieve The Desired Result. Features Of Bipap Machine With Humidifier: Simple, Reliable, Sensitive, And Quickly Synchronized With The Patient Applicable To Sleep Snoring And Sleep Apnea Patients, Cpap, S, S / T, T Operating Modes Ipap 4-30, Epap 4-30, 8-Step Inhalation-Exhalation Triggers Adapt The Pressure Automatically To The Patients Needs And Provides Better Synchronization Choose Between A Nasal Or Face Mask Available In S / M / L Sizes. Easily Adjust The Inhalationexhalation Pressure, Inhalation Time ( 0.5-3 Seconds ) And Respiration Rate. 5 Color Lcd Display With Interactive User Interface And Ergonomic Buttons Monitoring Vt, Res Rate, Min Vent, Leak. Alarms In All Respects. 5-Step Adjustment Of The Humidifier. Display Of The Key Parameters Of Therapy In The Online Mode Weight: 5 Kg, Dimensions 36 × 23 × 28 Cm Accessories- Humidifier, Mask, Hose, Adapter, Filter, User Manual , Pulse Oximeter : Integrated With Spo2 Probe Processing Display Module Can Be Used In Hospital, Home, Community Medical Treatment, Sports Healthcare, Etc. Can Be Measure Spo2 And Pulse Rate Accurately Spo2 And Pr Display, Pr Waveform And Barographs Display Battery Voltage Indicator, Rechargeable Li Battery 4 Direction Display, Four Levels Adjustable Brightness Pulse Sound Function, Alarm; Can Set Upper And Lower Limits. Usb Interface, Software, Analyses, Store, Print Low Power Consumption; Shut Off Automatically Small Volume ( 57 ( L ) X 32 ( W ) X30 ( H ) Mm ) Light To Carry Technical Parameters 1.3 65K Color Oled Display, Resolution 160 X128 Spo2: 35~99%, Pulse Ratio:30~250Bpm Resolution: 1% For Spo2, 1Bpm For Pulse Ratio Accuracy: ±2% ( 70%~99% ) , Unspecified ( <70% ) For Spo2, ±2Bpm Or± 2% ( Select Larger ) For Pulse Ratio Interference Resistance Capacity Against Ambient Light And Measurement Performance At Low Perfusion. , Infusion Pump : Should Be Provided With Peristaltic Pump Mechanism, Bolus: 600Ml / H, Flow Rate Range: 1-600Ml / H, Volume Limit: 1-9999 Ml, Accuracy:‡5% , Bio Amplifier Trainer Kit: The Trainer Kit Should Comprise The Ecg, M G And Eeg Amplifier Circuits Along With Supporting Accessories , Active Filters Kit For Bio Signals : This Should Comprise The Circuits Of Active Filters ( Active Low Pass Filters, Filters Kits Active High Pass Filters, Active Band Pass Filters, Active Notch Filters Etc. ) Used In Ecg, Emg And Eeg Measurements Along With Supporting Accessories , Adc Kits For Bio Signals : This Should Comprise For Circuit Modules For Converting Ecg, Emg & Ecg Signals Form Their Analog Form To Digital Form Along With Supporting Accessories , Emg Machine :Emg Amplifier 3 Lead With Audio And Usb Output Bipolar Real Time Emg Amplifier 3 Lead With Audio And Usb Trainer Real Time Emg Wave Measurement, Unipolar & Bi-Polar Mode Disc Electrodes With Velcro & Disposable Electrodes, Emg & Self-Test Mode, Gain & Test Adjustable. Usb & Dso Output. Audio Output Cw 1Wat ±., Test Point On The Top Of Instrument 2Mm Sockets Power Supply 230 V, 50Hz. Dimensions 305 X100 X 250 Mm± Study On Skrip Emg Amplifier Study Of Electric Potentials Generated By The Muscles, Muscle Activity, Nerve Conduction Velocity, Muscle Feedback, Muscle Strength & Signal Processing Placement Of Electrodes, Amplification, Filters, Gain, Self Test, Voltage & Frequency Responses & Etc Biowave Software Advance Software For Measurement Of Emg Single. It Is With Measurement Of Voltage, Time & Frequency. Setting Voltage & Time, Save As, Open, Print, Offset Setting, Etc. For Advance Study Values In Excel. , Hospital Information On System Software : The Software Module Should Comprise The Facility Of Monitoring Out- Patient Management, Purchase Management, In-Patient Management, Ot Management, Medication Orders, Laboratory Management, Pharmacy, Radiology, Blood Bank, Billing &Collection Etc , Ecg Machine : Ecg Amplifier 12 Leads Selector With Usb Ecg Amplifier 12 Leads With Selector Switch Trainer Kit 12 Leads Real Time Amplified. Ecg Output Up To 10Vpp± I, Ii, Iii, Avr, Avl, Avf, V1 To V6 Chest Lead, Standard Unipolar And Bipolar Leads Gain Adjustable, Self Test Clamp & Suction Electrodes.Dso O / P Through 4Mm Socket Test Point On The Top Of Instrument Through 2Mm Socket. Power Supply 230 ±10%, 50Hz, Dimensions 250 X 75 X 250 Mm± Study On Skrip Ecg Amplifier Measuring The Electrical Activity Generated By The Heart. Different Lead Combination Lead. Study Of Normal Abnormal Ecg Waves. & Signal Processing Placement Of Electrodes, Amplification, Filters, Gain, Self Test, Voltage, Frequency Responses, Etc Biowave Software Software For Measurement Of Ecg Single. Measurement Of Voltage, Time & Frequency Of Each Point. Setting Voltage & Time Expand The Signal, Save As, Open, Print, Etc. For Advance Study Excel Values, Offset Setting, Etc , Eeg Machine : Method Single Amplifier With Usb Trainer Kit Real Time Eeg Amplifier Output, 10-20 Electrodes Placements Electrodes Placement Select By Mode & Right & Left Switch Study Of Brain Activity & Signal Processing Eeg Left, Right & Self Test Mode, Gain Adjustable, Disc Electrodes Bipolar One Electrodes Set.Disc & Disposable Electrodes Eeg Dso & Usb Output Through 4Mm Socket & Usb Software Biowave, 6 Channel, Save, Open, Print, Excel Values, Measurement Voltage, Frequency, Time, Offset, Select 1 Or 6 Channel, Etc Test Point On Top Of Instrument, 2Mm Socket. Power Supply 230 ±10%, 50Hz, Dimensions 305 X100 X 250 Mm± , Temperaturesensortrainer Kit This Should Comprise On Board 4 Different Kind Temperatures Sensors ( Lm 35 , Rtd , Themister, Thermocouple Type ) Digital Display , Pressure Transducer Trainer Kit : Pressure Gauge: 0-150 Psi, Pressure Vessel: 0-100 Psi, Hoses Size: 1.5M, Digital Display Product Description Pressure Transducer Trainer Is Designed To Learn Concept Of Pressure Measurement. It Helps Students & Industry Professionals To Understand Operation Of Pressure Transducer In Detail. Built-In On / Off Controller Is Also Provided With Audio & Visual Indicators. It Also Has A Pc Interface Through Usb For More Interactive Understanding Of Transducer Characteristics. User Can Also Take A Direct Printout If Desired. Pressure Transducer Trainer Has A Wide Range Of Experiments With User Friendly Software. Features: Differential Input Pressure Transducer Precise Signal Conditioning Self-Contained And Easy To Operate Data Acquisition Using Usb Sensitive, Linear, Stable & Accurate Functional Blocks Indicated On Board Mimic On Board Digital Voltmeter On Board Indicators; Buzzer & Led On Board On / Off Controller , Piezoelectric Transducer Trainer Kit : Digital Display With 3 1 / 2 Digit To Read +1999 Counts, Donut Type 1000 Pf Piezo-Crystal , Colorimeter : Digital Photo Colorimeter 8 Filters, Mains Operated Using Latest Microcontroller, With 2½ Digit Led Display, Sample Size 1Ml. Auto Zero Using Touch Keys. , Uv – Vis Spectrophotometer ( Double Beam ) Wavelength Range : 190-1100Nm Spectral Bandwidth : 1 Nm Optical System : Double Beam, Blazed Holographic Grating ( 1200 Lines / Mm ) Wavelength Accuracy : ±0.5Nm Wavelength Repeatability : =0.2Nm , Auto Analyzer:The Machine Should Have The Provision Totest Like Sgpt, Lipid Profie, S. Creatin, Blood Cholesterol, Etc. , Electrolyte Analyzer : 1. Designed For 3 Electrolytes Analysis: Na+, K+, Cl- 2. Low Reagent Consumption Per Test. 3. Aspirates Whole Blood, Serum, Urine And Other Biological Fluids. 4. Requires Very Low Sample, 40Ul For 2 Electrolytes. 5. Throughput 60 Samples / Hour 6. Graphic Display With Touchscreen. 7. Automatic Calibration And Rinsing. 8. Inbuilt Thermal Printer 9. Real Time Clock 10. Memory For Sample Results 1000 11. Iso, Gmp And Ce Mark Certified Products. 12. High Linearity For Parameters. Sodium = 40-220 Mmol / L Potassium = 1 - 30 Mmol / L Chloride = 20-250 Mmol / L , Blood Gas Analyzer : Should Be Able To Measure Directly Ph, Pco2, Po2, Sodium, Potassium, Chloride, And Calcium Simultaneously. Calculated Parameters Include Sa02, Bi-Carbonate ( Hco3 ) , Standard Hco3, Base Excess Of Blood ( Be ) , Base Excess Of Extra Cellular Fluid. Should Have An Automatic Calibration For All The Measured Parameters. Should Have An Inbuilt Printer And Minimum Inbuilt Memory Of 100Samples. Fast Analysis Time -Less Than 60 Sec. Data Display On Well-Illuminated, Adequate Size Lcd Color Touch Screen Display. Data Print Out On Built In Graphic Printer. Should Be Supplied With On L I N E Pure Sine Wave Ups Of Sufficient Capacity For A Minimum Back Of 30 Minutes. Al Types Of Electrodes Supplied Initially Shall Have One Year Warranty. Reagents Supplied Should Have At Least Six Months Shelf Life. , Medical Oxygen Sensor : Measurement Range: 0-100%, Output In Ambient Air: 9-14 Mv, Operating Temperature: 0-50°C, Operating Humidity:0-99 Rh , Blood Cell Counter : White Blood Cells, Red Blood Cells And Platelets Are Counted Using The Direct Impedance Method With Coincidence Correction. Automatic Floating Discriminators Separate The Cell Populations Based On Complex And Accurate Algorithms. The Intensity Of The Electronic Pulse From Each Analyzed Cell Is Proportional To The Cell Volume. Principle Electrical Impedance Method For Cell Counting And Cyanide - Free For Hemoglobin Parameters Wbc, Lym#, Mid#, Gran#, Lym%, Mid%, Gran%, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Sd, Rdw-Cv, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Histograms Wbc, Rbc, Plt Throughput 60 Samples Per Hour , Clinical Thermometer ( Mercury Clinical Thermometer ) Range : 0-250°C , Digital Clinical Thermometer, Accuracy 0.1 Deg. C ( Min ) , Display. Human Body Non Contact Infrared Thermometer, Accuracy 0.1 Degree C, Lcd Display. , Infrared Clinical Thermometer: Human Body Noncontact Infrared Thermometer, Accuracy 0.1 Degree C, Lcd Display. , Stethoscope High Acoustic Sensitivity, Stainless Steel Combination Chest Piece Signify Quality. Soft-Sealing Ear Tips Offer Maximum Comfort And An Excellent Acoustical Seal. , Digital Stethoscope ( Phonocardiogram Trainer ) Pcg Amplifier With 5 Filters Phonocardiogram Amplifier With 5 Filter Trainer Kit Real Time Amplified Pcg Output Up To 15Vpp±, Pcg Transducer. Adjustable Gain & Adjustable Audio With Head Phone. Rotary Switch To Select 5 Positions Filter. Filter Range 25Hz To 1400Hz±, Heart Beat Indication. Output Pcg Through 4Mm Socket. Test Points On The Top Of Instrument Output Through 2Mm Socket. Power Supply 230V, 50Hz. Dimensions 250 X 75 X 250 Mm ± Study On Skrip Pcg Amplifier Study Of Phonocardiogram ( Or Pcg ) Is A Plot Of High-Fidelity Recording Of The Sounds And Murmurs Made By The Heart With The Help Of The Machine Pcg. Study Of Heart Sound & Murmurs. Study Of The Condition Of The Heart. Study Of Heart Sound For Analysis Provides Good Information Of These Diseases- Cardiovascular Diseases. Study Of Rhythmic Beating Of Heart. Study Of A Sound Referred To As “Lub- Dub” . Study Of The Atrio-Ventricular And The Aortic-Pulmonic Valves , Sphygmomanometer : Aneroid Type Sphygmomanometer , Electromyography ( Emg ) With Simulator Trainer : Emg Amplifier 3 Lead With Simulator Bipolar Real Time Emg Amplifier 3 Lead With Audio & Simulator Trainer Kit Real Time Emg Wave Measurement, Unipolar & Bi-Polar Mode Disc Electrodes With Velcro & Disposable Electrodes, Emg & Self Test Mode, Gain & Test Adjustable.Dso Output Through 4Mm Sockets Audio Output Cw 1Wat ±., Test Point On The Top Of Instrument 2Mm Sockets Simulator Differential 3 Led As Active, References & Common ( Ground ) . Adjustable Conduction I.E. Voltage & Time Response I.E. Frequency. Universal Output Sockets, Multiple Pattern By Adjustment Of Voltage & Frequency. Study On Skrip Emg Amplifier Study Of Electric Potentials Generated By The Muscles, Muscle Activity, Nerve Conduction Velocity, Muscle Feedback, Muscle Strength & Signal Processing Placement Of Electrodes, Amplification, Filters, Gain, Self Test, Voltage & Frequency Responses, Simulator & Etc Power Supply 230 V, 50Hz. Dimensions 305 X100 X 250 Mm± , Online Ups :Max-2Kva 72V Pure Sine Wave Without In-Built Batteries, Multicolor , Computed Radiography System : Computed Radiography System , Maintenance Tools Kit Box:Box Contain: 3-3 / 4 Auto Range Digital Multimeter, 23Pcs 1 / 4 Driver Socket Set, Heavy Duty Curved Claw Hammer W / Fiberglass Handle, Adjustable Wrench 8, Ci Extractor, Hobby Vise, Slip-Channel Pump Pliers 254Mm, 12-15 Nos Prosoft Screw Driver Set, Wire Stripper &Cutter, Fine Tip Straight Tweezer, Utiliyu Component Storage Box, Long Nose Plier 135Mm, Diagnoal Cutting Plier 110Mm, Linemans Plier 165Mm, Dual Color Cutting Plier, Dual Color Long Nose Plier, 9 Pcs Ball Point Longarmhex Key Set, 10Pcs Electronic Combination Wrench, 5 Pcs Needle Filr Set, Soldering Iron 220 V, Desoldering Wick, Solder Core, Vs Insulated Tap, Utility Knife, Measuring Tap; Desoldering Pump, Flux Bottle, Blow Brush, Telescopic Magnetic Pick Up Tool, Inspection Mirror, Al Purpose Snip Etc, , Hay, Sbridge Trainer Kit : Inductance Measurement Range: 50Mh To 150Mh Product Description Hays Bridge Trainer Is Used To Design Hay’S Bridge, Which Determines The Value Of Unknown Inductors ( L ) . The Students Can Balance The Bridge Either By Observing Waveform On Cro Or By Using The Built In Speaker. This Kit Has Been Designed Keeping Students In Mind So Its Very Easy To Understand And Use. Details:- Inductance Measurement Range: 50Mh To 150Mh. On Board Oscillator Section. On Board Circuit For Designing Hay’S Bridge On Board Amplifier Section On Board Unknown Inductors For Conducting The Experiment On Board Speaker Interface Test Points Are Provided To Analyse Signals At Various Points On / Off Switch And Led For Power Indication. Bare Board Tested Glass Epoxy Smobc Pcb Is Used. Block Description Screen Printed On Glassy Epoxy Pcb All Interconnections Are Made Using 2Mm Banana Patch Cords Supplied With User Manual And Patch Cords With Built-In Power Supply Enclosed In A Wooden / Plastic Box , Anderson’S Bridge Trainer Kit : This Is Useful For Students To Determination Of Self Inductance Of A Coil By Anderson’S Bridge. Features • Stand Alone System • Inbuilt Audio Frequency Generator • In-Built Stable 3.5 Character Digital Meters • 0-20 V Variable Power Supply •Easy To Learn And Illustrative Study Materials • Attractive , Durable And Insulating Wooden Casing. Technical Specifications On Board Dc Power Supply : +12V Dc Ammeter Range : 1?A To 200Ma Display : 3½ Digit Voltmeter Range : 1Mv To 200V Display : 3½ Digit Mains Power : 230V Ac ±10% , De Sauty Bridge Trainer Kit : This Is Useful For Students To Determination Of Self Inductance Of A Coil By Anderson’S Bridge. Features • Stand Alone System • Inbuilt Audio Frequency Generator • In-Built Stable 3.5 Character Digital Meters • 0-20 V Variable Power Supply •Easy To Learn And Illustrative Study Materials • Attractive , Durable And Insulating Wooden Casing. Technical Specifications On Board Dc Power Supply : +12V Dc Ammeter Range : 1?A To 200Ma Display : 3½ Digit Voltmeter Range : 1Mv To 200V Display : 3½ Digit Mains Power : 230V Ac ±10% , Flex Displays ( With Printing Charges ) : 2 Ft X 1.5 Ft , Wall Clocks : Digital , Boyle’S Law Apparatus : Burrete Graduated In C ( Or Ml ) With 1.0 C / Div. Scale Graduated Onboth Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( With Extra 500Gm Mercury ) . Superior N & Closed Ytpe Eno Meter Onlg Kaet Wood Board No Heavy Metal Base Fitted With Leveling Screws Without Mercury But Complete Whti Pressure Rubber Tubing &Glass Tubes, Routine Quality, Double Rod With Open &Closed End Tubes & Pressure Tubing. , P-N Junction Diode Characteristic Kit : Complete Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias. , Galvanometer With Resistance Kit ( Half Deflection Method ) :Galvanometer Is Designed For Very Low Current Measurement, Resistance 100 H / 500 , Time Period 10S To 15S, Large Moment Of Inertia Of The Moving Part, Deflection Closely Proportional To The Electric Charge. , Verification Of Kirchhoff’S Law Kit : Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance 1-, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Cd Voltmeter Available On Board -Yes, Range Of Dc Voltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords. Available For Interconnection- Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit. Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit. , Stoke’S Law Apparatus : Hard Glass Tube Of 35 Mm Dia & 1M Long Marked Ni Least Division Of Mm Is Made To Stand Firmly In Between Two Upright Bars With The Help On A Heavy Cast Iron Base At The Lower Side, For Viscosity Measurement, Transparent Liquid Like Glycerine Or Castor Oil To Be Supplied, Digital Stop Watch And Stainless Steel Balls Of Different Dia To Be Supplied. , Spherometer : A Fine Screw Moving In A Nut Carried On The Centre Of A Small Three-Legged Frame, The Feet Forming The Vertices Of A Equilateral Triangle. , Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup : Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Fo Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5N / M, 8 N / M, 07 N / M. Consisting Of 45Cm Long Mirror Scale, Spring, Slotted Weight With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 05Mc High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm. Weight Complete With Hook For Hanging. , M.I. Of Flywheel Apparatus :M.I. Of Flywheel Apparatus Good Quality Stainless Steel Full Setup, Csi Superior Quality Flywheel With Weights, Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter:20 Cm, Wall Type With Pointer, With Revolution Counter, Set Of Slotted Weights For Flywheel Complete With Weights Cord And Hook. , Coefficient Of Linear Expansion Apparatus: Superior Quality, Height 50 Cm, With Brass Rod, Stainless Steel Finish A50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor. Three Metal Tubes - Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point. Thermoplastic Elastometer Tubing With 2 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td- 8556A Steam Generator. A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords. , Time Period Of Vibration Of Cantilever : Steel Made Cantilever Beam Clamped At The Table, Free End Fitted With Hook To Suspend Weights, Complete Set With Digital Stopwatch. , Proof Of Inverse Square Law By Photo Electric Cell :Proof Of Inverse Square Law By Photo Electric Cell Complete Test Kit With Optical Bench Mounts For P.E. C E L L& Source Of Light, Galvanometer Of Low Resistance To Measure Current. , Dependence Of Capacitance Of Parallel Plate Capacitor: The Fixed And Mobile Plate Is Highly Insulated. The Solid Aluminum Plate Capacitor Around 150Mm Diameter And 3Mm Thick. The Capacitance Si Adjustable From 2.3 To 280Pf. Ti Consists Of A Fixed And A Movable Plate On A Guide Rail. A Centimeter Scale Is Used To Read The Plate Spacing. The Device Si Supplied With Three Dielectric Sample Plates Made Of Acrylic, Pvc. , G Clamp 100Mm , Instrument To Observe The Effects Of Frictions Using Inclined Plane Consisting Of A Wooden Plane 90X18cm Having Adjustment Ofr Setting The Required Angel Precisely Complete With Frictionless Pulley Linear And Circular Scale Nap B O T T O M Fo Different A Wheeled Trolley Dnaa Materials. , Stainless Steel Led Digital Outside Micrometer: Digital Micrometer Outside.0 - 25 Mm L.C. 0.001 Mm. , Conversion Of Galvanometer Into Voltmeter Kit :Conversion Of Galvanometer Into Voltmeter Kit Type Of On-Board Meter Available - Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - , 1 Number Of Variable Dc Power Supply Available On Board- 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available No Board- Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic. , Conversion Of Galvanometer Into Ammeter Kit :Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard Ot Vayr Load Resistance - 1, Mruneb Ovfariable Cd Power Supply Available On Board - , 1 Number Of Led Indicators Available Ot Indicate Power Niput - 1, Availability Of Dc Voltmeter Available No Board - Yes, Availability Of Dc Ammeter On Board -Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic. , Dc Digital Ammeter Range: 0-10V , Dc Digital Voltmeter Range: 0-20V , Analog Galvanometer : Dc Galvanometer Analogue For Lab 30-0-30V Portable For Detecting And Indicating An Electric Current. , Small Resistances Range : 5O, 10O , Dc Digital Multimeter : Multimeter Digital 3Digit Lcd- Dc Voltage Up To 1000V In Five Ranges, Ac Voltage Up To750v In Five Ranges, Dc Current Up To 10A In Five Ranges, Ac Current Up To 10A Ni Five Ranges, Resistance Upto 200M Ni Seven Ranges With Buzzer.
Contract Date: Aug 18, 2025 Contract Value : 1.34 Crore
Government Departments No of Bidders 8
West Bengal View Result →
14.
Health and Family Welfare #7625205 AOC
Medicine Suture Surgical Material Pathology Item General Item Machinery Equipment , Medicine, Suture Surgical & Material, Pathology Item, General Item & Machinery Equipment , Tab. 5-Fluro Uracil500 Mg , Tab. Abacavir 300 Mg , Tab. Aceclofenac + Paracetamol + Serrapeptidase 100 + 325 +10Mg , Tab. Aceclofenac + Paracetamol + Serrapeptidase 100 + 500 +15Mg , Tab. Aceclofenac 100 Mg+ Paracetamol500 Mg +Chlorzoxazone 500Mg , Tab. Aceclofenec 100Mg , Tab. Acetazolamide 250 Mg , Tab. Acetylsalicylic Acid (Aspirin) 25 Mg , Tab. Acetylsalicylic Acid 150 Mg , Tab. Acyclovir 200 Mg , Tab. Acyclovir 800 Mg , Tab. Albendazole 400 Mg , Tab. Allopurinol300 Mg , Tab. Allopurinol 100 Mg , Tab. Alprazolam 0.25 Mg , Tab. Amiodarone 100 Mg , Tab. Amlodipine 5 Mg+ Atenolol 50Mg , Tab. Amlodipine 10 Mg , Tab. Amlodipine 5 Mg , Tab. Ambroxol 30Mg+Salbutamole 2 Mg+Theophylline 100 Mg , Tab. Amoxycillin+Clavulanic Acid (Amoxycillin 500 + Clavulanic Acid 125Mg) , Tab. Amoxycillin+Clavulanic Acid (Amoxycillin 200 + Clavulanic Acid 28.5Mg) , Tab. Amoxycillin+Clavulanic Acid (Amoxycillin 250+ Clavulanic Acid 125Mg) , Tab. Artemether (A) + Lumefantrine (B) 20 Mg (A) + 120 Mg (B)1X6 , Tab. Artemether (A) + Lumefantrine (B) 80 Mg (A) + 480 Mg (B) , Tab. Artemether (A) + Lumefantrine (B)Oral Liquid 80 Mg (A) + 480 Mg (B)/5 M , Tab. Ascorbic Acid (Vitamin C)100 Mg 100 Mg , Tab. Aspirin 75 Mg , Tab. Atenolol 50 Mg , Tab. Atenolol100 Mg , Tab. Atorvastatin 10 Mg , Tab. Atorvastatin 40 Mg , Tab. Azithromycin 250 Mg , Tab. Azithromycin 500 Mg , Tab. Baclofenbaclofen 40 Mg , Tab. Betahistine 8 Mg , Tab. Betamethasone 0.5 Mg , Tab. Bicalutamide 50 Mg , Tab. Bisacodyl 5Mg , Tab. Bisacodylsuppositories 5 Mg , Tab. Calcium Carbonate . 500 Mg , Tab. Calcium 500 Mg , Tab. Calcium Leucovorin50mg , Tab. Calcium With Vitamin D3calcium Equivalent To 500 Mg & Vit. D3 250 Iu , Tab. Capeciine500 Mg , Tab. Carbamazepine 200 Mg , Tab. Carbimazole 10 Mg10strip , Tab. Carboplatin450 Mg , Tab. Cefixime 200 Mg , Tab. Cefixime 50 Mg , Tab. Cefixime 100 Mg & Of0loxacin 100 Mg Dispersible , Tab. Cefixime 200 Mg & Azithromyin 250 Mg , Tab. Cefpodoxime + Clavunate 200+125Mg , Tab. Cefpodoxime- 200 Mg , Tab. Cetirizine 10 Mg , Tab. Cetirizine 5Mg+Ambroxol 60 Mg , Tab. Chloroquine 250 Mg , Tab. Chlorpromazine 100 Mg , Tab. Chlorthalidone12.5Mg , Tab. Chlorthalidone25mg , Tab. Cinnarizine 25 Mg , Tab. Ciprofloxacin 250 Mg , Tab. Ciprofloxacin 500 Mg , Tab. Cisplatin50 Mg , Tab. Clarithromycin 250 Mg , Tab. Clofazimine 100 Mg , Tab. Clofazimine 50 Mg 4 , Tab. Clomiphene Citrate50 Mg , Tab. Clonazepam 0.5 Mg , Tab. Clopidogrel 75 Mg , Tab. Clotrimazole (Vaginal )Pessary 500 Mg (With Applicator)Single , Tab. Clozapine 25 Mg , Tab. Clozapine 50 Mg , Tab. Cyclophosphamide500 Mg , Tab. Dapsone 100 Mg , Tab. Deferasirox 250Mg , Tab. Deferasirox 500 Mg30 , Tab. Deferiprone 500Mg , Tab. Deriphylline Sr 300 Mg , Tab. Dexamethasone 0.5 Mg , Tab. Diazepam 5 Mg , Tab. Diclofenac 50 Mg , Tab. Diclofenac 50 Mg+Paracetamol 500Mg , Tab. Diclofenac 50 Mg+Serrtiopeptidase 15 Mg , Tab. Dicyclomine 500 Mg , Tab. Dicyclomine Hydrochloride 20 Mg , Tab. Diethylcarbamazine 100 Mg , Tab. Digoxin 0.25 Mg , Tab. Digoxin 250 Mg , Tab. Diloxanide Furoate 500 Mg , Tab. Diltiazem 60 Mgl , Tab. Diltiazemsr90 Mg , Tab. Diltizem 30 Mg , Tab. Diphenylhydantoin 30 Mg , Tab. Dispersablehydroxyurea100 Mg , Tab. Disulfiram 250 Mg , Tab. Docetaxel120 Mg , Tab. Domperidone 10 Mg , Tab. Donepezil 5 Mg , Tab. Doxorubicin50 Mg , Tab. Drotaverine 40 Mg , Tab. Empagliflozin25 Mg , Tab. Enalapril Maleate 10 Mg , Tab. Epirubicin100 Mg , Tab. Erlotinib 150 Mg , Tab. Escitalopram 10 Mg , Tab. Ethamsylate250 Mg , Tab. Ethinylestradiol (A) + Levonorgestrel (B) 0.03 Mg (A) + 0.15 Mg (B) , Tab. Ethinylestradiol 0.01 Mg , Tab. Ethinylestradiol 0.05 Mg , Tab. Etophylline+Theophylline 100 Mg (Etophylline 77+Theophylline 23 )Mg , Tab. Etoposide100 Mg , Tab. Etamsylate 250 Mg , Tab. Exemestine 25 Mg , Tab. Ferric Carboxymaltose250mg , Tab. Ferrous Ascorbate(100Mg. Elemental Iron+Folic Acid 1.5 Mg) , Tab. Finofibrate160 Mg , Tab. Finofibrate 40 Mg , Tab. Fluconazole 150 Mg , Tab. Flunarizine 5 Mg , Tab. Fluoxetinecapsule 20Mg , Tab. Folic Acid 5Mg , Tab. Furazolidone 100 Mg , Tab. Furusemide 40 Mg , Tab. Gabapentin 300Mg & Methylcobalamin 500Mg , Tab. Gefitnib 250 Mg , Tab. Gemciine1.4 Mg , Tab. Glibenclamide 5 Mg , Tab. Gliclazide 80 Mg , Tab. Glimeperide 1 Mg , Tab. Glimeperide 2 Mg , Tab. Gutta Percha (Gp)30/Bottel , Tab. Haloperidol 5 Mg , Tab. Hydrochlorothiazid 12.5 Mg , Tab. Hydrochlorothiazid 50 Mg , Tab. Hydrochlorothiazide 25 Mg , Tab. Hydroxychloroquine 200 Mg , Tab. Hydroxyzine25 Mg , Tab. Ibuprofen 400Mg , Tab. Imatinib Mesylate400 Mg , Tab. Imipramine 25 Mg , Tab. Iron & Folic Acid Sugar Coatediron And Folic Acid Sugar Coateddried Ferrous Sulphate Ip Eq. To 45 Mg Ferrous Iron And 400 Mcg Folic Acid Ip (Pink Colored ) - , Tab. Iron & Folic Acid Sugar Coatediron Folic Acid Sugar Coated (Blue ) Ferrous Sulphate Ip Equivalent To60 Mg Elemental Iron & 500 Mcg Folic Acid Ip , Tab. Iron & Folic Acid Sugar Coatediron Folic Acid Sugar Coated (Red ) Ferrous Sulphate Ip Equivalent To60 Mg Elemental Iron & 500 Mcg Folic Acid Ip , Tab. Isosorbide -5-Mononitrate 20 Mg , Tab. Isosorbide Dinitrate 5 Mg , Tab. Itraconazole/Capsule 100 Mg , Tab. Ivermectin 12 Mg , Tab. Ketorolac10 Mg , Tab. Labetalol 100 Mg , Tab. Lenalidomide 25 Mg , Tab. Letrozole 2.5Mg , Tab. Levetiracetam 250 Mg , Tab. Levodopa (A) + Carbidopa (B) 100 Mg (A) + 10 Mg (B) Cr , Tab. Levodopa (A) + Carbidopa (B) 100 Mg (A) + 25 Mg (B) Cr , Tab. Levodopa (A) + Carbidopa (B) 250 Mg (A) + 25 Mg (B) , Tab. Levofloxacin 250 Mg , Tab. Levofloxacin 500 Mg , Tab. Levonorgestrel 0.75 Mg , Tab. Levothyroxine 100 Mcg100per Bottle , Tab. Levothyroxine 50 Mcg100per Bottle , Tab. Linezolid 600 Mg , Tab. Lithium Carbonate 300 Mg , Tab. Loperamide 2 Mg , Tab. Lorazepam 1 Mg , Tab. Losartan10 Mg , Tab. Mebeverine 200 Mg10 X 15 , Tab. Medroxy- Progesterone 10 Mg , Tab. Mefenamic Acid + Drotaverine , Tab. Metformin + Gliclazide 500+80Mg , Tab. Metformin 500 Mg , Tab. Metformin-Sr1000mg10x15 , Tab. Methotraxate50 Mg , Tab. Methyl Ergometrine Maleate 0.125 Mg , Tab. Methyldopa 250 Mg , Tab. Methylprednisolone 16 Mg , Tab. Methylprednisolone 4 Mg , Tab. Methylcobalamin. 1500 Mg, Vitamin D3 1000 Iu, Folic Acid 1.5 Mg, L-Arginine 250 Mg, L-Carnitine 250 Mg, L-Tartrate & N-Acety Cysteine Usp 250 Mg , Tab. Medroxypogesone Acetate 10 Mg , Tab. Methylcobalamin, Folic Acid And Pyridoxine Hci Oral Disintegrating 1500Mcg, 5Mg & 20Mg , Tab. Metoclopramide 10 Mg , Tab. Metoprololsr25 Mg , Tab. Metoprololsr/Plain50 Mg , Tab. Metronidazole 400 Mg , Tab. Mifepristone 200 Mg1 Per Pack , Tab. Misoprostal 100Mcg , Tab. Misoprostal 200 Mcg4in 1 Pack , Tab. Misoprostol 200Mcg (Oral/ Vaginal) , Tab. Montelukast 5 Mg , Tab. Morphine 10 Mg , Tab. Morphine+I469sr/30 Mg , Tab. Multivitamin Sugar Coated Nfi Formula Sugar Coated Vit A 2500 Iu , Vit C 50Mg, Calcium Pantothenate- 1Mg,Vit B1 2 Mg Vit B6 0.5 Mg Vit D3 200 Iu Vit , Tab. Nicotinamide 50 Mg7 , Tab. Nifedipine 10 Mg , Tab. Nitroglycerine (Glyceryl Tri Nitrate)Sub-Lingual0.5 Mg10 , Tab. Norfloxacin 400 Mg , Tab. Norfloxacindispersible100mg , Tab. Ofloxacin200 Mg , Tab. Ofloxacin400mg , Tab. Olanzapine 5 Mg , Tab. Olanzapine10 Mg , Tab. Ondansetron 4 Mg , Tab. Ormeloxifene 30 Mg , Tab. Omeprazole, Domperidone 20+10 Mg , Tab. Oxaliplatin100 Mg , Tab. Paclitaxel260 Mg , Tab. Paracetamol 500Mg , Tab. Paracetamol 650Mg , Tab. Paracetamol 325Mg + Diclofenac K 50Mg + Streptopeptidase 120Mg , Tab. Paracetamol Chlorzoxane & Diclofenacsodi Pot 325Mg + 250Mg + 50Mg , Tab. Paracetamol 170Mg + Dextromethorphanhbr5mg+Chlorpheniraminemaleate 1.5Mg+Phenylephrine Hcl2.5Mg , Tab. Penicillin V (Phenoxymethyl Penicillin)250 Mg , Tab. Phenobarbitone 30 Mg , Tab. Phenobarbitone 60Mg , Tab. Phenytoin/ Diphenylhydantoin 100Mg , Tab. Povidone Iodinevaginal Pessary 200Mg10 X 10 , Tab. Prednisolone 10Mg , Tab. Prednisolone 20 Mg , Tab. Pregabalin 75Mg And Nortriptyline 10 Mg , Tab. Prednisolone 20Mg , Tab. Prednisolone 30Mg , Tab. Prednisolone 40Mg , Tab. Pregabalin 150 Mg , Tab. Primaquine 15 Mg , Tab. Primaquine 2.5 Mg , Tab. Primaquine 7.5 Mg , Tab. Propranolol 10 Mg , Tab. Pyridoxine 10 Mg , Tab. Pyridoxine 100 Mg , Tab. Pyridoxine 40 Mg , Tab. Quinine 300 Mg , Tab. Rabeprazole 20 Mg , Tab. Ramipril 2.5 Mg , Tab. Ranitidine 150 Mg , Tab. Ranitidine, Dicyclomine (150+10Mg) , Tab. Ranitidine, Domperidone (150+10Mg) , Tab. Riboflavin 5 Mg7 , Tab. Risperidone 2 Mg , Tab. Salbutamol 4 Mg , Tab. Seratiopeptidase + Diclofenace Pottasium 10+50Mg , Tab. Sitagliptin 50 Mg , Tab. Sodium Valproate 500 Mg , Tab. Sorafenib 200Mg , Tab. Spironolactone 25 Mg , Tab. Sucralfate 20 Mg , Tab. Sulfamethoxazole And Trimethoprim800mg +160Mg , Tab. Sulfamethoxazole+ Trimethoprim (Pediatric S) 400 Mg+80 Mg , Tab. Sulfamethoxazole+Trimethoprim200mg +40 Mg , Tab. Sulfamethoxazole 100Mg And Trimethoprim 20Mg , Tab. Sulfasalazine 500 Mg , Tab. Sulfadoxine 500Mg + Pyrimethamine 25Mg , Tab. Sumatriptan 25 Mg , Tab. Sunitinib/Capsule50 Mg , Tab. Tamoxifen 10 Mg3 , Tab. Tamoxifen20 Mg , Tab. Tapentadol 100 Mg , Tab. Telmisartan 40 Mg , Tab. Temozolamide 250 Mg , Tab. Thiamine 100 Mg7 , Tab. Thinylestradiol (A) + Levonorgestrel (B) 0.03 Mg (A) + 0.15 Mg (B) With Ferrous , Tab. Tinidazole 300 Mg , Tab. Tramadol 50Mg , Tab. Traexamic Acid 500 Mg And Mefenmic Acid 250Mg , Tab. Tranexamic Acid 500Mg , Tab. Trihexyphenidyl 2 Mg , Tab. Tolperisone Hydrochloride 150 Mg , Tab. Verapamil 40 Mg , Tab. Vincristin1 Mg , Tab. Vartin 16 , Tab. Vitamin. B Complex Nfi (Prophylactic) B1 2 Mg, B2 2Mg, B6 0.5 Mg, Niacinamide 25 Mg, Calcium Pantothenate 1 Mg , Tab. Warfarin 1 Mg , Tab. Warfarin 2 Mg , Tab. Warfarin 5 Mg , Tab. Zinc Sulphate Dispersible 10Mg , Tab. Zinc Sulphate Dispersible 20Mg10 X 10 , Tab. Zoledronic Acid4 Mg , Tab. Zolpidem10 Mg , Cap. Amoxycillin 250 Mg10 X 10 , Cap. Amoxycillin 500 Mg10 X 10 , Cap. Ampicillin 500 Mg10 X 10 , Cap. Camphor 25Mg, Chlorathymol 5Mg, Eucalyptol 125Mg, Menthol 65 Mg & Terpinrecol 120 Mg , Cap. Cephalexin 250 Mg10 X 10 , Cap. Clindamycin 150 Mg10 X 10 , Cap. Cloxacillin 125 Mg10 X 10 , Cap. Cloxacillin 500 Mg10 X 10 , Cap. Cholecalciferol Usp 60000 Iu , Cap. Cycloserine 125 Mg10 X 10 , Cap. Doxycycline 100Mg10x10 , Cap. Flupirtine Maleate 100 Mg , Cap. Hydroxyurea 500 Mg , Cap. Nifedipine 5 Mg10 X 10 , Cap. Pomalidomide 2 Mg , Cap. Rifampicin 150Mg , Cap. Rifampicin 300Mg , Cap. Rifampicin 450Mg , Cap. Rifampicin 600Mg , Inj. Acyclovirinj 250 Mg/Vialvial , Inj. Adenosineinj 3 Mg/ Ml -2 Ml Amp , Inj. Adrenalineinj 1 Mg/ Ml1 Ml Amp , Inj. Amikacininj 100 Mg/2 Ml2 Ml Vial , Inj. Amikacininj 500 Mg/2 Ml Vial2 Ml Vial , Inj. Aminophylline Inj 25 Mg/ Ml10 Ml Vial , Inj. Amiodaroneinj 50 Mg/ Ml3 Ml Amp , Inj. Amoxycillin+Clavulanic Acid (Amoxycillin 500 + Clavulanic Acid 100 Mg)/ , Inj. Amphotericin B 50 Mgvial/Ampoules , Inj. Ampicillininj 500 Mg/Vialvial , Inj. Anti D Immunoglobulin For Iv/Im Use (Monoclonal)Inj 150Mcg1 Ml Vial , Inj. Anti D Immunoglobulin For Iv/Im Use (Monoclonal)Inj 300Mcgpfs/Vial , Inj. Anti Snake Venominj Polyvalent 10 Ml (Lyophilized)10 Ml Vial , Inj. Antitetanus Immunoglobulinsinj 250 Iu/Vialvial , Inj. Artesunateinj 60 Mg /Vialvial , Inj. Artesunatepowder For Injection 120 Mg , Inj. Atracurium 10 Mg/ Ml2.5 Ml Amp , Inj. Atropine 0.6 Mg/ Ml2 Ml Amp , Inj. Bendamustineinj 100 Mg , Inj. Benzathine Penicilline12 Lakh Iu/Vialvial , Inj. Benzathine Penicilline6 Lakh Iu/Vialvial , Inj. Betamethasone 4 Mg/Ml1 Ml Amp , Inj. Betamethasone Sodium Phosphateinj 4 Mg/ Ml1 Ml Amp , Inj. Biphasic Isophane Insulininsulin Biphasic Aspart 30:70 100 Iu/Ml (Firm Has To Supply Compatible Pen Along With Cartridges As And When Required Without Any , Inj. Bleomycininj 15 Mg , Inj. Bortezomib 2 Mg , Inj. Bupivacaine Hcl 0.5% 20 Ml Vial , Inj. Caffeine Citrateinj 20 Mg/ Ml3 Ml Vial , Inj. Calcium Gluconateinj 10%10 Ml Vial , Inj. Carboprost (15-Methyl Pgf2a)Inj 250Mcg1 Ml Amp , Inj. Cefotaximeinj 1Gm/Vialvial , Inj. Cefotaximeinj 250 Mg/Vialvial , Inj. Cefotaximeinj 500 Mg/Vialvial , Inj. Ceftazidimepowder For Injection 1Gm , Inj. Ceftazidimepowder For Injection 250 Mg , Inj. Ceftriaxoneinj 1 Gm/Vialvial , Inj. Ceftriaxoneinj 250 Mg/Vialvial , Inj. Ceftriaxoneinj 500 Mg/Vialvial , Inj. Chloroquineinj 40 Mg/ Ml5 Ml Amp , Inj. Chlorpheniramineinj 10 Mg/ Ml10 Ml Vial , Inj. Ciprofloxacininj 200 Mg/100 Ml100 Ml Ffs Bottle , Inj. D-10 (Dextrose 10%)Iv Fluid (Dextrose 10%)500 Ml Ffs Bottle , Inj. D-25 Injection (Dextrose)Iv Fluid (Dextrose 25%)100 Ml Bottle , Inj. D-25 Injection (Dextrose)Iv Fluid (Dextrose 25%)500 Ml Bottle , Inj. Decarbazine 200 Mg10 Mg /Ml , Inj. Desferrioxamineinjection 500 Mgvial , Inj. Dexamethasoneinj 8 Mg/2 Ml2 Ml Vial , Inj. Dextrose 5%Iv Fluid(Dextrose 5%)500 Ml Ffs Bottle , Inj. Dextrose With Salinei/V Fluid (Dextrose 5% + Saline 0.9%)500 Ml Ffs Bottle , Inj. Diazepam 5 Mg/ Ml2 Ml Amp , Inj. Diclofenac 25 Mg/ Ml3 Ml Amp , Inj. Dicyclomine Hydrochloride 10 Mg/ Ml2 Ml Amp , Inj. Diltiazeminjection 5 Mg/Ml , Inj. Dobutamineinj 50 Mg/ Ml5 Ml Amp , Inj. Dopamineinj 40 Mg/ Ml5 Ml Amp , Inj. Doxorubicininj 50 Mg , Inj. Drotaverine 40 Mg/2 Ml2 Ml Amp , Inj. Drotaverineinj 40 Mg/2 Ml2 Ml Amp , Inj. Duvadilan 5Mgvial , Inj. Enoxaparin Inj 40 Mg Equivalent To-4000 Iuvial/Pfs , Inj. Erythropoietininjection 10000 Iu/Ml , Inj. Erythropoietininjection 2000 Iu/Ml , Inj. Esmolol 10 Mg/Ml , Inj. Etophylline +Theophylline 220 Mg/2 Ml (169.4+50.6 Mg)2 Ml Amp , Inj. Ferric Carboxymaltose50mg/Ml20 Ml Vial , Inj. Fluphenazineinjection 25Mg1ml Vial/ Ampoules , Inj. Fulvestrantinj 500 Mg , Inj. Furusemideinj 10 Mg/ Ml2 Ml Amp , Inj. Gentamicininj 40 Mg/ Ml2 Ml Amp , Inj. Glucose (A) + Sodium Chloride (B)Injection 5% (A) + 0.9% (B)500Ml Ffs , Inj. Glycopyrolate 0.2 Mg/ Ml1 Ml Amp , Inj. Haloperidolinj 5 Mg/ Ml1 Ml Amp , Inj. Heparin Inj 1000 Iu5 Ml Vial , Inj. Hepatitis B Immunoglobulin100 Iu/Vialvial , Inj. Human Chorionic Gonadotropininjection 10000 Iuvial Of 1 Ml Injection , Inj. Human Chorionic Gonadotropininjection 5000 Iuvial Of 2 Ml Injection , Inj. Hyaluronidase 1500Iu , Inj. Hydrocortisoneinj 100 Mg/Vialdry Powder 100Mg/Vial , Inj. Hydroxy Propymethyl Cellulose 2% Prefilled Syringe 3Ml , Inj. Hydroxyethyl(6% Saline Solution For Infusion)Starch 6%Ip , Inj. Hyoscine Butylbromide20mg /Ml1 Ml Vial/Amp , Inj. Ifosfamideinj 1 Gm , Inj. Inj. Deferoxamine500mg/Vial , Inj. Insulin Solubleinj 40 Iu/ Ml10 Ml Vial , Inj. Irinotecaninj 100 Mg , Inj. Iron Sucroseinj 100 Mg/5 Ml5 Ml Amp , Inj. Iv Human Immunoglobin 5% Iv Ig(5Mg/100Ml Each), , Inj. Ketamine 10 Mg/ Ml10 Ml Vial , Inj. Labetalolinj 20 Mg/4 Ml4 Ml Amp , Inj. Labetalolinjection 5 Mg/Ml , Inj. Lignocaine 2% 30 Ml Vial , Inj. Lignocaine+Adrenaline 2% + 0.005 Mg/ Ml30 Ml Vial , Inj. Lorazepaminj 2 Mg/ Ml1 Ml Vial , Inj. Magnesium Sulphate 500 Mg/Ml , Inj. Mannitolinj 20%100 Ml Ffsbottle / 350 Ml Ffs Bottle , Inj. Medroxy- Progesteroneacetateinjection 150 Mg1 Ml / Vial , Inj. Mephentermine 30 Ml Vial Mg/Ml10 Ml Vial , Inj. Meropenem500 Mgvial , Inj. Methyl Ergometrine Maleate 0.2 Mg/ Ml1 Ml Amp , Inj. Methylprednisoloneinjection 1000 Mg/Mlvial , Inj. Methylprednisoloneinjection 500 Mgvial Of 4 Ml , Inj. Metoclopramideinj 5 Mg/ Ml2 Ml Amp , Inj. Metronidazole 500 Mg/100 Ml100 Ml Ffs Bottle , Inj. Midazolam 1 Mg/ Ml 5 Ml Amp/ 10Ml Vial , Inj. Morphine 10 Mg/ Ml1 Ml Amp , Inj. Morphineinjection 15 Mg/Mlvial , Inj. Naloxoneinj 0.4 Mg/ Ml1 Ml Amp , Inj. Neostigmine 0.5 Mg/ Ml1 Ml Amp , Inj. Nitroglycerine (Glyceryl Tri Nitrate)Inj 25 Mg/5 Ml5 Ml Amp , Inj. Noradrenalineinj 2 Mg Base/2 Ml Amp.2 Ml Amp , Inj. Ondansetroninj 2 Mg/ Ml2 Ml Amp , Inj. Oxytocin Injection 5Iu/Mlinjection 5 Iu/Ml1 Ml Ampule , Inj. Pantoprazoleinj 40 Mg/Vialvial , Inj. Paracetamol150 Mg/ Ml2 Ml Amp , Inj. Pemetrexedinj 500 Mg , Inj. Pentazocine 30Mg/Ml1 Ml Ampule , Inj. Pheniramineinjection 22.75 Mg/Ml2 Ml Vial , Inj. Phenobarbitoneinj 200 Mg1 Ml Amp , Inj. Phenytoininj 50 Mg/ Ml2 Ml Amp , Inj. Phytomenadione 10 Mg/Ml10 Mg Ampule , Inj. Pioglitazone15mg , Inj. Piperacillin +Tazobactam 4.5 Gm/Vialvial , Inj. Pralidoxime (Pam)Inj 25 Mg/ Ml20 Ml Amp , Inj. Premix Insulin30:70 Injection (Regular:Nph)2 , Inj. Premix Insulin30:70 Injection 40 Iu/Ml , Inj. Promethazine 10 Mg/Mlone Injection 1 Vial , Inj. Promethazine 50 Mg (25Mg/ Ml)2Ml Vial/Ampoules , Inj. Propofal 10 Mg/Ml1 Ml /Vial , Inj. Protamine 50 Mg/5 Ml , Inj. Quinineinj 300 Mg/ Ml2 Ml Amp , Inj. Rabies Immunoglobulin300 Iu/2 Ml2 Ml Vial , Inj. Rabies Vaccine (Cell Culture) Id/Iminj 2.5 Iu/ Ml1 Ml Vial , Inj. Ranitidineinj 50 Mg/2 Ml2 Ml Amp , Inj. Ringer Lactatei/V 0.24 % V/V Of Lactic Acid ( Eq. To 0.32% W/V Of Sodium Lactate), 0.6 % W/V Sodiumloride, 0.04 % W/V Potassium Chloride And 0.027 % , Inj. Risperidone 50 Mgvial Of 2 Ml , Inj. Rituximabinj 500 Mg , Inj. Sodium Bicarbonate Inj7.5% W/V10 Ml Amp , Inj. Sodium Chloride - Hypotonicinj N/2(0.45%)500 Ml Ffs Bottle , Inj. Sodium Chloride - Isotonicinj 0.9% Isotonic(Equivalent To Na+154 M Mol/L, Cl+154 M Mol/L)100 Ml Ffs , Inj. Sodium Chloride - Isotonicinj 0.9% Isotonic(Equivalent To Na+154 M Mol/L, Cl+154 M Mol/L)500 Ml Ffs , Inj. Streptokinaseinjection 15 Lac/Vialvial , Inj. Succinyl Choline 50 Mg/ Ml10 Ml Vial , Inj. Surfactant Suspension 25 Mg/Ml100 Ml Vial , Inj. Thiamineinjection 100 Mg/Ml1 Ml/Vial , Inj. Thiopentone 0.5Gm Powder/Vial20 Ml Vial , Inj. Topotecaninj 4 Mg , Inj. Tramadol 50 Mg/ Ml2 Ml Amp , Inj. Tranexamic Acid 500 Mg/5 Ml.5 Ml Amp , Inj. Trastuzumabinj 440 Mg , Inj. Urokinase(5 Laciu)Vial , Inj. Vancomycinpowder For 1 G , Inj. Vancomycinpowder For Injection 250 Mg , Inj. Vancomycinpowder For Injection 500 Mg , Inj. Vecuronium 2 Mg/ Ml2 Ml Amp , Inj. Verapamil 5 Mg/2 Ml , Inj. Vinblastininj 10 Mg , Inj. Vinorelbineinj 10 Mg , Inj. Vitamin B12 ,Injection500 Mcg/Ml(30 Ml Amp/ Vial) , Inj. Vitamin K11 Mg/0.5 Ml0.5 Ml Amp , Inj. Water For 2 Ml Amp , Inj. Water For 5 Ml Amp , Drops Atropine1% Eye Drops5 Ml Vial , Drops Boro-Spirit Ear Drops-0.183 Gm Boric Acid In 2.08 Ml Of Alcohol , Drops Carboxy Methyl Celluslose 10 Ml , Drops Carboxymethyl-Cellulosedrops 0.5%10 Ml/Vial , Drops Ciprofloxacineye / Ear Drop 0.3%5 Ml Vial , Drops Combo Ear Drop- Chloramphenicol 5% W/V+Clotrimazole 1%+Lignocainehydrochloride 2%Combo Ear Drop- Chloramphenicol 5% , Drops Dexamethasonedrop(0.1%, 5Ml),Eye 5Ml Eye Drop , Drops Fluconazoleeye3 Mg/Ml(10 Mlvial),Eye Drop10 Ml , Drops Gentamicin Ear(0.3%)5 Ml Vial , Drops Homatropine 2% 5Ml , Drops Hydroxypropyl Methyl Cellulose 0.3% W/V Eye 10Ml , Drops Lantanoprost0.005%(5Ml),Eye 5Ml , Drops Moxifloxacin0.5% W/V(5 Ml),Eye 5Ml , Drops Normal Salinenasal Drops: Sodium Chloride Drops 0.05% W/V , Drops Ofloxacin 0.3% + Dexamethosne + Na Phosphate 0.1% Eye 5Ml , Drops Paracetamol- 125Mg/Ml15 Ml Bottle With Dropper , Drops Phenylephrine Hcl 5% + Tropicamide 0.8% Eye 5Ml , Drops Pilocarpine 4%5 Ml Bottel , Drops Pilocarpinedrops 1%5 Ml Bottel , Drops Pilocarpinedrops 2%5 Ml Bottel , Drops Povidone Iodine 1% (Septidine) Eye 10Ml , Drops Prednisolonedrops 1%10 Ml Bottel , Drops Sodium Aminosalicylate Granules10 Gm , Drops Timolol0.5% Eye Drops5 Ml Vial , Drops Tobramycin 0.3% Eye 5Ml , Drops Tropicamidedrops 1%5 Ml Drop , Drops Wax Solvent Ear Benzocaine2.7% W/V10 Ml Bottel Drop , Drops Wax Solvent Ear Drops: Paradichloro- Benzene2 % W/V10 Ml Bottel , Drops Xylometazolinenasal Drops 0.05 %, , Drops Xylometazolinenasal Drops: Adult (0.1%) , Inhaler Halothane 250 Ml Bottle , Inhaler Isoflurane 250 Ml Bottle , Inhaler Ipratropium Inhalation (Mdi/Dpi)20 Mcg/Dose Ipratropium Respirator Solution , Inhaler Tiotropium Inhalation(Dpi) 18 Mcg/Dose , Inhaler Tiotropium Inhalation(Dpi) 9 Mcg/Dose , Inhaler Salbutamol Inhaler 100Mcg/Dosemetered Dose Container , Ointment Hydrocortisone 0.5% , Ointment Hydrocortisone 1% , Ointment Povidone Iodine5% Ointment15 Gram Tube , Ointment Acyclovir3% -5Gm Tube , Ointment Gum Paint Tannic Acid 2% , Ointment Betamethasone 0.05% 15 Gm , Ointment Aceclofenac + Linsed Oil + Methyl Salicylate + Menthol 30Gm , Syp. Dextromethorphan 10Mg/5Ml 50 Ml , Syp. Dextromethorphan 10Mg/5Ml 100Ml Pack Bottle , Syp. Albendazole200mg/5 Ml10 Ml Bottle , Syp. Ambroxol Hcl 15Mg + Terbutaline Sulphate 1.25Mg + Guaiphenesin 50Mg 5Ml ((Additional Composition Of Menthol Also Acceptable) 100Ml Bottle), Syrup , Syp. Ambroxol Hcl 15Mg + Terbutaline Sulphate 1.25Mg + Guaiphenesin 50Mg , Syp. Ambroxol 30Mg, Salbutamol 2Mg, Guaiphenesin 50Mg/5Ml, 100Ml , Syp. Amoxycillin+Clavulanic Acid (Amoxicillin 200Mg+ Clavulanic Acid , Syp. Amoxycillin 125Mg + Clavulanate Pot.31.25Mg Dry Syrup (30Ml) , Syp. Azithromycin Suspension 100Mg/5Ml 15Ml , Syp. Azithromycinsyp 200Mg/5Ml15 Ml Bottle , Syp. B-Complex (Nfi Foumula) Vit.B1 2Mg, Vit.B2 2Mg, Vit.B6 0.5Mg, Niacinamide 25Mg, Calcium Pantothenate 1Mg 100Ml , Syp. Bromhaxine Hcl 8Mg + Trebutaline 2.5Mg/5Ml Syrup (50Ml) , Syp. Bromhexine Hcl 4Mg, Guaiphenesin 50Mg, Terbutaline Sulphate 1.2Mg/5Ml 100Ml , Syp. Bromhexine Syp 4Mg/5Ml50 Ml Bottle , Syp. Caffeine Oral Liquid 20 Mg/Ml , Syp. Carbamazepine Oral Liquid 100 Mg/5 Ml , Syp. Cefixime + Clavunate 50+31.25Mg , Syp. Cefiximeoral Suspension 100Mg/5Ml10 Ml Bottle , Syp. Cefpodoxime + Clavunate 30Ml , Syp. Cephalexinsyp 125Mg/5Ml30 Ml Bottle , Syp. Cetirizinesyp 5Mg/5Ml30 Ml Bottle , Syp. Cetrizine Hcl 5Mg, Ambroxol Hcl 30Mg/5Ml, 60Ml Syrup , Syp. Chloroquinesyp 160Mg /10Ml(50Mg/5Ml Base)60 Ml Bottle , Syp. Chlorpheniramine Maleate (Paracetamol 125Mg + Phenylpherine 5Mg + Cpm 0.5Mg + Sodiym Citrate 60Mg + Menthol 1Mg) , Syp. Codeineoral Solution 15 Mg/5 Ml60 Ml Bottle , Syp. Diphenhydramine 100Ml , Syp. Diethylcarbamazine Oral Liquid 120 Mg/5 Ml , Syp. Domperidone1mg Per 1Ml Suspension30 Ml Bottle , Syp. Doxycyclinedry50 Mg/5 Ml , Syp. Etiophylline And Theophylline Paediatric Syrup. (100Ml Bottle) , Syp. Furazolidone 25Mg + Metronidazole Benzoate 100Mg/5Ml 60Ml Syrup , Syp. Gum Paint (Tannic Acid)2% W/V15 Ml Bottle , Syp. Haemoglobin 2.09G, Ferric Ammo Cit125mg, Vitb1, 17.5Mcg, Folic Acid 0.5Mg, Alchol0.87Ml (5.5%V/V) Per 15Ml, 200Ml (Syrup) , Syp. Hydroxyzine 10 Mg/5 Ml , Syp. Iron & Folic Acidsyp Iron Each 1 Ml Contains 20Mg Elemental Iron+Folic Acid , Syp. Lactulosesolution 10 Gm /15 Ml100 Ml Bottle , Syp. Levosalbutamol50mcg/Dose , Syp. Levosulbutamol 100 Mcg , Syp. Metronidazoleoral Suspension 200 Mg/5Ml60 Ml Bottle , Syp. Montelukast Syrup60 Ml Bottle , Syp. Multivitamin With Protein 200 Ml , Syp. Drop Multi Vitamin (Appro. 22 Drops) Each Ml Contains Vitamin A Ip 3000 Iu 1Mg, Riboflavine Phosphate Sodium Ip 2Mg, D Panthenol Ip 2.5Mg Miacinamide Ip 10Mg Pyridoxine Ip 1Mg Cyanocoblamine Ip 1Mg Lagine Hcl Usp 10Mg , Syp. Ofloxacin + Tinidazole (50+100Mg), 30Ml Syrup , Syp. Ondansetronsyp 2Mg/5 Ml30 Ml Bottle , Syp. Paracetamol 125Mg/5 Ml60 Ml Bottle , Syp. Pediatric Solution Like Isolyte P, N/2 & N/5Pediatric Solution Like Isolyte P, N/2 , Syp. Potassium Chloride Oral Solution 100Mg/Ml200 Ml Bottle , Syp. Potesium Chloride Oral Solution 200Ml Bottle Each 15Ml Postsium Chloride Ip 100Mg , Syp. Promethazinesyp 5Mg/ 5Ml60 Ml Bottle , Syp. Salbutamol 1Mg, Theophylline 50Mg, Bromhexine 4Mg, Per 5Ml (100Ml Syrup) , Syp. Salbutamol 2Mg + Guaiphenesin 100Mg + Bromhexine Hcl 4Mg/Ml Syrup. (50Ml) , Syp. Salbutamol Syp 2Mg/5Ml60 Ml Bottle , Syp. Sodium Valproate Each 5Ml Contains 200Mg200 Ml Bottle , Syp. Sucralfate 1Gm/5Ml100ml Bottle , Syp. Sulfamethoxazole+Trimethoprimoral Liquid ( 200Mg + 40 Mg) / 5 Ml50 Ml Bottle , Syp. Vitamin A 100000 Iu/Ml With Marked Spoon For 1Ml &2Ml100 Ml Bottle , Syp. Zinc Sulphate Syrup 20Mg/5Ml (100Ml) , Tube Atropine1% Eye Ointment3 Gram , Tube Atropinesulphate 1%, , 3 Gm , Tube Benzoyl Peroxidegel 5% , Tube Betamethasone Dipropionateointment 0.05%15 Gram , Tube Chloramphenicoleye Ointment 0.5%4G/5G , Tube Ciprofloxacineye Ointment 0.3%3/3.5 Gram , Tube Clotrimazole Cream2%W/W15 Gram , Tube Diclofenac 0.01 , Tube Diclofanac Diethylamine, Linseed Oil, Methyl Salicylate & Menthol 30 Gm Gel , Tube Duvadilan10 Mg10x50 , Tube Framycetin Sulphate1% Cream30 Gram , Tube Fusidic Acidcream/Ointment 2%5 Gram , Tube Ketoconazole, Neomycin, Iodochlorhydroxyquinoline, Tolnaftate, Chobetasol Propionate 15 Gm Gel , Tube Lignocaine 2% 30 Gram , Tube Miconazolecream 2% W/W15 Gram , Tube Mupirocincream/Ointment 2%5 Gram , Tube Povidine-Iodine Germicidegargle 20% W/V , Tube Salicylic Acidointment 6% 30 Gm , Tube Silver Sulphadiazine Cream Usp 1% 25 Gram , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine (Age Group 15 Or Above)Tab Artesunate 200 Mg(3Tab) + Sulphadoxine 750 Mg(2Tablets) + Pyrimethamine , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine (Age Group 9 To 14 Years)Tab Artesunate 150Mg (3Tab)+ Sulphadoxine 500Mg (2 Tab)+Pyrimethamine 25Mg , Combo Pack Artesunate + Sulphadoxine + Pyrimethamine(Age Group Between 1-4 Years)Tab Artesunate 50 Mg (3 Tab) + Sulphadoxine 500 Mg(1 Tab) + Pyrimethamine 25 Mg , Combo Pack Combi-Pack With Mifepristone + Misoprostol(1 Tablet Of Mifepristone 200 Mg And 4 Tablets Of Misoprostol 200Mcg)Combi Pack , Ampule Budesonide Nebulising Suspension Containing Budesonide 0.5 Mg/2 Ml2 Ml , Jelly Glycerin Oral Liquid , Gel Choline Salicylate Lignocaine Hcl With Benzalkonium Chloride Gel 15Gm , Oral Suspension Amoxycillin125 Mg/5 Ml30 Ml Bottle , Oral Suspension Chlorpheniramineoral Liquid 2 Mg/5 Ml , Oral Suspension Ibuprofen 100Mg/5Ml60 Ml Bottle , Oral Suspension Rehydration Salts Ip 4.4Gm (Sodium 75, Potassium 20, Chloride 6, Citrate10, Dextrose 75) , Oral Suspension Valproateoral Solution 200Mg/5Ml100 Ml Bottle , Powder Bleaching Powder Containing Not Less Than 30% W/W Of Available Chlorine (As Per I.P)Containing Not Less Than 30% W/W Of Available Chlorine (As Per I.P) , Powder Glucose Packet 75 Mg For Ogtt Testglucose Packet 75 Mg For Ogtt , Powder Anti Bacterial Powder, 10 Gm ( Neomycin Sulphate 5 Mg, Baccitracin 250 Unit, Sulphacetamide Sodium 60 Mg) , Powder Reduced Osmolarity Ors Pkt. Who Formulao.R.S. Glucose- 75Meq,Sodium- 75M Eq Or M Mol /L,Chloride - 65Meq Or M Mol/L, Potassium- 20Meq Or M Mol/L , Citrate- 10M Mol/L Osmolarity -245M Osm/L,Dextrose 13.5G/L Sodium Chloride 2.6G/L Potassium , Powder Electrolyte Sachect , Solution Hydrogen Peroxide Solution 6% , Solution Povidone Iodine Solution 5%,100 Ml Bottle , Solution Enema Sodium 100 Ml (Sodium Acid Phosphate 10 Gm, Sodium Phosphate 8 Gm / 100 Ml) With Tube , Solution Eosin 2% Solution (1X250 Ml),Consumable , Solution Ethanol (Abosolute Alcohol 99.9% (500Ml) , A.C. 1 Ton Split 3 Star , A.C. 1.5 Ton Split 3 Star , A.C. 2 Ton Split 3 Star , A.C. Window 1.5 Ton 3 Star , A.C. Window 2 Ton 3 Star , Abdominal Belt(32 Inch Each), , Abdominal Belt(34 Inch Each), , Abdominal Belt(36 Inch Each), , Abdominal Belt(38 Inch Each), , Absolute Alcohol (Ethanol)(1X500 Ml = 500 Ml), , Absorbable Gelatine Sponge Ip 80Mm X 50Mm X 10Mm , Absorbent Cotton Roll 100 Gm , Absorbent Cotton Wool Ip 500 Grms (Roll), , Acetic Acid - Solution(3% 100 Ml Bottle), , Acetone Detection Kit , Acralic Board (Saineaj Board Acralic Sheet) , Adesive Lable For Sputam Container , Adhesive Plastcloth Based Usp 7.5 Cm X 5 Mts/Roll , Adhesive Plast Cloth Based 1 Inch X 5 M / Roll , Adhesive Tape 7.5Cm X10 (Mtr/Roll), Cloth Based , Adult Brief Daiper Set- Made Of Ultra Absorbent Material With Leakage Barrier & Having Soft, Flexible Leg Elastic. With Wetness Indicator. Made Up Of Woodpulp, Sap, Absorbent Nonwooven Fabric. The Set Contatin Two Pcs Of Medium Daiper {Nominal Size 81Cm-111Cm} For Waist Size 31-44 & Three Pcs Of Large Daiper {Normal Size 85Cm-128Cm} For Waist Size 34-50 , Ahg Sera 5Ml(Each), Coombs , Alchlol Absouite 500Ml (Ethanol) 99.9% , Alcohal Based Hand Sanitizer(500Ml Bottle With Dispenser), , Alkaline Phosphate(100 Ml (5 X 20)), , All Human (Bovine Aprotinin Free) Fibrin Sealant(1 Ml), , All Human (Bovine Aprotinin Free) Fibrin Sealant(2 Ml), , All Out Machine With Refill , All Out Refill , Almeera (Cr Sheet 1.00 Mm) Size 1675X840x480 Mm (Iron) , Almeera (Cr Sheet 1.00 Mm) Size 1980X915x480 Mm (Iron) , Almeera Full Size (78X3619) Sheet Gauge 20 (Iron) , Almehra Iron 6X3x1.5”, 22 Gauge , Aluminium Bartan , Ambu Bag / Adult Each -1700Ml, With Oxygen Connecting Tube ,Should Be Supplied With A Carry Pouch , Ambu Bag Should Be Complete With Required Autoclavable Valves And Other Accessories,(Should Have Silicon Rubber Bellow To Withstand Autoclave At 134 Deg.C), , Ambu Bag / Resuscitator Silicon 200-250 Ml Infant Size-Each, With Oxygen Connecting Tube ,Should Be Supplied With A Carry Pouch , Ambu Bag Should Be Complete With Required Autoclavable Valves And Other Accessories,(Should Have Silicon Rubber Bellow To Withstand Autoclave At 134 Deg.C) Should Be Multiple Times Autoclavable), , Ammonium Sulphate (Analar (Gr/Ar) (1X500 Gm = 500Gm), , Anc Table 6X2.5X3 Of Iron (Lxwxh) , Anteriar Veginal Wall Retractor , Anti A Sera Igm(10 Vial), , Anti Abd Grouping Serum 3X10ml , Anti B Sera Igm(10 Vial), , Anti Malaria Larva Oil Harbal Based 5 Litter Can , Anti-D (Polyvalent)(1X10 Ml), , Antiseptic Concentrate For Floor Clening Pack Of 5 Litter Can , Ast/Got 600 Ml , Attandent Bed Powder Coted 72Lx30Wx24H , Auramine O , Auto Clave (Poratable) Single Drum Aluminum Seamless Construction Made Of Albminium Alloy With Turning On Lid Highly Polished. It Comes With One Stop Cock (Continus Bleeding Valve) Safety Valve And Pressure Guage Size 12X12X12X20 , Auto Cleanser For Cbc Machine(2 Liter), , Auto Dill Solution For Cbc Machine(20 Liter), , Auto Lyser Solution For Cbc Machine(500Ml), , Auto Pippets Fixed Volume 10 Micro Liters Each Syring , Auto Pippets Fixed Volume 1000 Micro Liters Eachsyring , Auto Pippets Fixed Volume 20 Micro Liters Each , Autoclave Cooker Type , Autoclave Ss , Double Walled Size (22X12) With Stand (Manual) Isi Marked , Autoclave Ss , Double Walled Size (24X16) With Stand (Manual)Isi Marked , Autoclave Ss , Electric Operated Size (14X12)With Stand , Autoclave Ss , Electric Operated Size (20X12) With Stand , Autoclave Ss , Eletric Operated Size (22X12)With Stand , Autoclave Vertical , B.B Silk Size-3/0 (12 Foils/Pkt)(3/8Cir Rcut Needle 26Mm Length 76 Cm),Needle , B.B Silk With 1/2 Cir Rb Needle Size:1/0 20 Mm Length 75 Cm Non Absorbable Surgical Sutures Usp Surgical Material , B.B Silk With 1/2 Cir Rb Needle Size:2/0 30 Mm Length 75 Cm Surgical Material , B.B. Silk 6 Reels X 25 Mts Length 25 Mts. Black Braided Silk Without Needle In Reels Non Absorbable Surgical Sutures Usp 3-0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels), , B.B. Silk 6 Reels X 25 Mts Length 25 Mts.Black Braided Silk Without Needle In Reels Non Absorbable Surgical Sutures Usp-, 2-0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels ),Surgical Material , B.B. Silk 6 Reels X 25 Mts Size:1/0(6 Reels Is Per Box Rate Should Be Quoted For 6 Reels),Surgical Material , Baby Diapers Small (10 Diaper Per Pkt) Standard Company , Baby Feeding Spoon 1 Ml , Baby Feeding Spoon 2 Ml , Baby Feeding Spoon 5 Ml , Baby Feeding Spoon Feeding Of Milk Steel , Baby Oxygen Maskall Sizes , Baby Towile , Baby Tray Ss 15X18Of Ss With Cover Pack Of Of Ss With Cover , Baby Weigh Machine Capacity 20Kg Resolution : 10 Gm Pan/Platform : 550Mmx300mm (Min) Electronic , Bag For Carrying Kit/Material During Home Visit 2X1.5X1 , Balanced Salt Solution 500 Mlbottle(Each), , Barium Chloride 10% (500 Ml Bottle) , Barraquer Wire Speculum, Large(Num), , Basic Carbol Fuchsin For Afb Staining 25 Gm/Pkt , Basic Fuchine 25Gm (Dye Content 85% To 88%) , Basic Fuchisin(Sep.Chemical Name: Pararosaniline Hydrochloride,Chemical Structure: C20h20c1n3 Mol Wt:337.86, Dye Content: Approx 85%-88% &Dye Content Must Be Mentioned) Colour Metallic Green. , Bathroom Air Freshner Odonil , Battery 70D 26 Rmf For Vehicle , Bed Pan Female With Cover (Made Of Stainless Steel) , Bed Pan Male With Cover (Made Of Stainless Steel) , Bed Side Bench 3X1.5X1.5 Steel , Bedside Locker Standard Size , Bedside Locker Standard Size Ss Top , Bilrubin Total & Direct Auto 3X100ml (Span/Tulip/Erba) , Bio Hazard Labels A4 Size , Bio Hazard Lables , Bio Metric Attance Machin Menul Operated , Bio Metric Attance Machine Online Operated , Biochemistry Control Serum L1 5X5 Ml , Biomedical Waste Collection Plastic Bag(Yellow)(450X450 Mm 55 Micron Pkt Of 100Pcs), , Biomedical Waste Collection Plstic Bag(Black 450X450 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Black 750 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Black 900 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Blue 450X450 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Blue 750 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Blue 900 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Red 450X450 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Red 750 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Red 900 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Yellow 750 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biomedical Waste Collection Plstic Bag(Yellow 900 X 900 Mm 55 Micron Pkt Of 100Pcs) , Biometric Thumb Impression Machine 250 Emp. , Black Gogle For Cataract Patient , Black-Braided Silk With 1/2 Cir Cutting Needle 30Mm Length 75 Cm(1/0 12 Foils/Pkt), , Black-Braided Silk With 1/2 Cir Rb Needle 20 Mm Length 75 Cm 1/0 13 Foils/Pkt , Black-Braided Silk With 1/2 Cir Rb Needle 30 Mm Length 75 Cm 2/0 12 Foils/Pkt , Blanket For Baby , Blankets For Neonates , Bleaching Powder Gr-Ii Is 1065/1989 With Upto Datepacked In 25 Kg Hdpe Bags Isi Marked Stable , Blood Administrations Set Adult , Blood Bag Warmer , Blood Bag With Acd/Cpd Solution (Disposable Sterilised) With Needle(100 Ml),Bag , Blood Bag With Acd/Cpd Solution (Disposable Sterilised) With Needle(350 Ml),Bag , Blood Cell Counter Key(Key), , Blood Grouping Anti Sera A Monoclonal(10 Ml Vial), , Blood Grouping Anti Sera B Monoclonal : Antisera Should Be Transparent With More Than One Year Shelf Life At 2-6 C , It Should Give +++ Agglutination At 1.256 Dilution In 3-4 Sec With B Positive Cells 10 Ml , Blood Grouping Anti Sera D Monoclonal :-Antisera Should Be Transparent With More Than One Year Shelf Life At 2-6 C, It Should Give +++ Agglutination At 1.256 Dilution In 3-4 Sec With D Antigen Positive Cells. 10Ml Vail (Eryclone Anti-D Igm) , Blood Vessel Introducers Needles 16G, Sterilized, Set , Bloting Paper(Paper), , Bone Cutter Small , Bone Gauze Large , Bone Gauze Medium , Bone Gauze Small , Bone Holding Forcep For Femur Bone , Bone Holding Forcep For Humerus Bone , Bone Holding Forcep For Radius Ulna Bone , Bone Punch , Bone Spikes Medium , Bone Spikes Small , Bovine Albumin (22% W/V)(1X5=5 Ml), , Bowelss Size 20 , Bowel Baual Size 8 Powder Coated , Bowel Size 20 Powder Coated , Bp Instrument Cell , Bp Instrument Digital , Bp Instrument Marcury Isi Mark , Broom Stick For Sputum Smear Prepration (8 Inches) , Brown Tap (2 Inches) , Brown Tap (5 Inches) , Bubble Cpap Machine , Bucket Brackets (For Hanging Set Of Single Fire Buckets) With Out Fire Bucket , Bucket Brackets (For Hanging Set Of Three Fire Buckets) With Out Fire Bucket , Burn Cage (Bed Cradle) , Canan India Photocopier Presser Roller , Canulated Reamers For Femur , Canullated Drill Bit For4mm Screws , Canullated Tap For4mm Screws , Capillary Tube 100 Pieces , Capillary Tube Biluribin Pack Of 100 Pieces , Carbol Fuchsin For Zn Stain (500Ml Bottle) , Carbolic Acid (Phenol) - Spc. Chemical Structure C6h50h, Molecular Wt: 94.11, Melting Point : 40 Digree C 2,Purity : 99.5% , Carbondioxide Gas In Medium Size Cylinder(B Type),Miscellaneous , Carbondioxide Gas In Small Size Cylinder(A Type),Miscellaneous , C-Arm Macchine , Cartage Brother Printer 1580 Mf New , Cartage Canan 2006N Photocopier Machine , Cartage Canon Printer Hl 6230/6240 New , Cartage Durm , Cartage Hp Printer 05A New , Cartage Hp Printer 12A New , Cartage Hp Printer 16A New , Cartage Hp Printer 49 A New , Cartage Hp Printer 88A New , Cartage Samsung Printer Ml2010 New , Cartain Complete(Plasic With Ring And Stiching) Standrd , Cassette (14X17), For X-Ray , Cassette (8X10), For X-Ray , Catgut Chromic (12 Foils/Pkt)(Size:1/0 Length 150 Cm), , Catgut Chromic Size:2/0 Length 150 Cm , Catgut Chromic With 1/2 Cir Rb Needle 30 Mm Length 70Cm No. 1 -0, 12 Foils Per Packet , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 75Cm No. 1-0, 12 Foils Per Packet , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 75Cm No. 2-0, 12 Foils Per Packet , Catgut Chromic With 1/2 Cir Rb Needle 40 Mm Length 76 Cm (With Needle) ) Absorbable Surgical Sutures Usp,(Size 1, 12 Foils/Pkt),Surgical Material , Catgut Chromic With 1/2 Cir Rb Needle Size:1/0, 30 Mm Length 76Cm Absorbable Surgical Suture Surgical Material , Catgut Chromic With Cd Rb Needle 30 Mm Length 76 Cm Size:2/0 Absorbable Surgical Suture Surgical Usp, 12 Foils/Boxmaterial , Catheter Foleys Size 12-2 Way , Catheter Foleys Size 14-2 Way , Catheter Foleys Size 14-3 Way , Catheter Foleys Size 16-2 Way(11 Each), , Catheter Foleys Size 18- 2 Way , Catheter Foleys Size 20-2 Way(12 Each), , Catheter Foleys Size 22-2 Way(13 Each), , Catheter Foleys Size 24-2 Way(14 Each), , Catheter Long Line Silicon, G-24, Fr-2, L-30Cm , Catheter Suctionassorted 10 No/Each , Catheter Suction Assorted 9 No/Each , Catheter Suction Assorted Covering All Sizes 10,12,14,16,18 Disposable , Catheter Suction Sterile(Size Fg 20 (Disposable, Sterile Each) , Catheter Suction Sterile(Size Fg 22 (Disposable, Sterile Each) , Catheter Suction Sterile(Size Fg 6 (Disposable, Sterile Each) , Catheter Umbilical With Leur Lock(Fr-3 To Fr 3.5 , L-40 Cm) , Catheter Umbilical With Luer Lock Stopcock Fr-2, L-40 Cm , Catheter Umbilical With Luer Lock Stopcock Fr-3, L-40 Cm , Catheter Umbilical With Luer Lock Stopcock Fr-4, L-40 Cm , Catheter Umbilical With Luer Lock Stopcock Fr-5, L-40 Cm , Catheters Single Lumen Set Adult(Size - 6F To 8F, Length 13 Cm To 15 Cm, Each), Femoral , Catheters Single Lumen Set Pediatric(Size - 3F To 4F, Length 13 Cm To 15 Cm Or Less), Femoral , Catheters Single Lumen Size Adult Femoral , Catheters Single Lumen Size Size Pediatrics Femoral , Cathetor Tray Ss With Cover 16X3 , Cbnat Machine , Cc Camera 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera 2 Way Audio. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:-Cc-31/Bma-231/Hevs-209-3G/Hl110/Va-2W380/Al-Col-106/Vaccs 200 , Cc Camera, 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera With Supply. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:-Cc-30/Bmc-430/Hev 20 01 /Hl109/Va-Ccs-Tvl2380/Al-Col-105A/Vaccs380s , Cc Camera, 1/4 Ccd, 3.6 Mm Board Lens 380 Tvl 2 Lux Color Plastic/Dust Proof Metal Body Camera. Make;- Impex/Sparsh/ Grovers/Hinum/Vantage/Alpha/Vision. Model:- Cc-72/Bmc-429/Dy-3723 Lph/Hl108/Va-Tvl380/Al-Col-104/Vaccs380 , Cc Camera, 10 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cc Camera, 10.1 Mega Pixle Cmos Sensor, Integreated Cleaning System, 2.5 Lcd Screen With 230K Pixle,1600 Viewing Angle, High-Precision 9 Point Af System, Picture Style Image Processing Parameters, Digic Ii Image Processor With 0.2 Sec Start Up - (Each) , Cc Camera, 16 Channel Color Digital Video Recorder, 500 Gm Hdd, Full Triplex, Real Time Display (30 Frame Per Second) Make:- Impex/Sparsh/Grovers/Hinum/Vvantage/Alpha/Vision. Model:-Dv-62/Mcd-62/Dvr-29-Hk/Hl205dvr/Va-Hd500/Al-4C/B2616v , Cc Camera, 16 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cc Camera, 20 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cc Camera, 24 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cc Camera, 6 Channel Mono Chrome Duplex Multiplexer With Osd, Time Date And Alarm Facility, Make:-Impex/Sparsh/ Grovers/ Hinum/Vvantage/Alpha/Visionmodel:-M-41/Mx-16/Cplm-30-3/Hl202mx/Vaad16/Al-Mux- 16B/Vaad 16 , Cctv Bullet Camera 2 Mp , Cctv Bullet Camera 4 Mp , Cctv Bullet Camera 6 Mp , Cctv Cable, 3 Core + Coaxialfor 2 Way/Silent Camera, Make:- Impex/Sparsh/Grovers/Hinum/Vvantage/Alpha/Vision/Isi Model:-C-32/Cc-3/Alc-3C/Isi With Fiting , Cctv Camera Fitting Charge Per Point , Cctv Dome Camera 2 Mp , Cctv Dome Camera 4 Mp , Cctv Dome Camera 6 Mp , Cctv Nvr 16 Channel Standard , Cctv Nvr 32 Channel Standard , Cctv Nvr 4 Channel Standard , Cell Clean For 5-Part Hematology Analyser All Model , Cell Pack, Reagent Pack For Cell Counter((Erma And Mindrug) Complete Set), All Instement , Centeral Oxygen Supply For 10 Bedcomplete Fitting , Centeral Oxygen Supply For 30 Bedcomplete Fitting , Centeral Oxygen Supply For 5 Bed Complete Fitting , Central Venous Catheter Kit(Single Lumen),Kit , Cervical Collar/Each-Soft, Medium Sized , Chair Cushion Foam Thickness 3 With Cotton Cover Box Type , Chikungunya Card Test 1 Gg + 1 Gm (25 Test/Kit) , Children Toys 1. ????, ???? ?? ????? ???? ??????-1 2. ???????? ??????-1 3. ???? ?????? ??? ???? ?? ???? ???? ?????????? ??????-1 4. ???-??? -1 5. ?????????? ???-1 (Total 5 Pcs) , Cholestreol Kit Pack Of 10X10ml (Span/Tulip/Erba) , Chromic With Cd.Rb Needle Absorbable Surgical Suture (12 Foils/Pkt)(40 Mm Length 76 Cm Size:1/0),Surgical Material , Cidex – 5Lter (2% Glutaldyhide) , Cidex Tray 10X5x3 , Cidex Tray 17X5x39 , Cidex Tray 26X53 , Cidex Tray 36X5x3 , Citric Acid Analar/Gr/Ar (1X500 Gm = 500Gm), , Coagulometre Single Chanel , Coconut Broom , Coline 500Ml , Collection Vail 2Ml Pack 100 , Collection Vail 5Ml Pack 100 , Colour Vision Chart , Commode Chair Folding A Commode Chair, Known In British English Simply As A Commode, Is A Type Of Chair Used By Someone Who Needs Help Going To The Toilet Due To Illness, Injury Or Disability. A Commode Chair Sometimes Has Wheels To Allow Easy Transport To The Bathroom Or Shower. , Commodetype Of Chair: Foldable Height Adjustable Material: Steel 25 X 19 X 19 Cm , Complete Delivery Kit-1Plastic Desposable Gown (Non Woven Plastic Laminated,Leak Proof)-2(4*4),(2).Disposable Goggles For Protection Of Eyes-2 (Free Size),(3).Face Mask-2 Free Size,(4).Plastic Disposable Cap(Non Woven Plastic Laminated,Leak Proof)(1Pair,(5).Long Gloves Elbow Length-2Pairs(6 1/2 And 7),(6)Disposable Shoe Covers,Till Calf(Plastic)-2Pair(Free Size)As Per Attached Specification), [987797] , Computer Chair , Computer Table (Size 4X2.6) With All The Fitting Of Parts , Computer Table 4’X2’ With All Fitting Of Parts , Cooler Size-21X19X36Isi Mark 16 Fan & Pump With Gi Sheet Body , Coombs Ahg Sera 5Ml(Each),Consumable , Corneal Knife Tooke (Num), , Corrugated Drainage Sheet, Sterile, Multichannel, Single Use(2 Inch X 6 Inch (Pvc)-Piece), , Cpap Machine , Crape Bandage Cotton Based 10Cm X 4M (Box Of 10 Bandages) , Crape Bandage Cotton Based 15Cm X 4M (Box Of 10 Bandages) , Crash Cart Emergency , Cresent Knife(1 Each), , Cresent Sics Blade (15 Degree) , Crp Test Kit (Latex/Card) (25 Test/Kit) , Currete Straight , Curtain Complete Cloth Silk With Ring And Sticky Stad. Size , Curved Scissors- Laparoscopic 5Mm Size, 360 Degree Rotating With Insulated Shaft, Non Ratchet , Plastic Grip(36 Cms Length, Monopolar Pin Provision For Usage With Electro Surgical Unit, Independently Moving Jaws), , Cvurrete Curved , Cyanemeth Solution For Hb 5 Litre , Cytochrome Stain With Buffer (500 Ml) , Cytoplasam Stain A&B Rapid Pap Pack Of 500Ml , D-Dimer(10X3 Ml), , Deaver Retractor Abdominal Central Oxygen Supply Complete Per Mtr , Defebrillator Biphasic, Features : Offers Variable Energy Level Selection, (2,3,5,7,10,20,30,50,70,100,150,200 Joules), Battery Capacity - 50 Shocks On Single Charge. Adult &Pediatric Paddles Support, Compact & Ligh Weight : Approx 5.0Kgs Max, Ecg Through Paddle , Dengurapid Test Card-Single Test , Dental Air Rotor Burs (Specification- Diamond Point Multilayered Color Banded Shanks -Straight Fissure, Round Number 0,2,4, Inverted Cone Tapered Fissure Edno Access And Endo Z Bur Assorted Bur, Isi/Iso/Ce Marked) , Dental Air Rotor Hand Place Oil Spray (Specification- Imported 500Ml, Isi/Iso/Ce Marked) , Dental Articulating Paper (Specification- 40 Microns Double Sided; Each Pack Contains One Dozen Articulating Paper Book) , Dental Barbed Broaches- Size 21Mm Size: 25Mm (Specification- • Stainless Steel • Handles Should Be Color Coded For Ease Of Identification • Designed For Bulk Removal Of Pulp Tissue • Pre-Sterilized In Individual Packing • Should Be Available In Both 21Mm And 25Mm Sizes • Should Be Available In Individual And Assorted Packing) , Dental Bone Graft (Specification- • Xenogenic And Synthetic Material • 300-2500Mm Size • Perioglass, Adbone, Bio-Oss, Gem-21 • Resorbable) , Dental Calcium Hydroxide Powder & Zinc Phosphate Cement (Specification- Fda Approved, Ce Marked) , Dental Composite Anterior Micro Fill (Specification- Fda Approved Imported Isi/Iso/Ce Marked) , Dental Composite Material Nano Hybrid (Light Cure) (Specification- Dentsply/3 M/Kulzer/ Similar/ Isi/Iso/Ce Marked Complete Kit With Multiple Shades. Etchant And Bonding Agent, Applicator Tips/Brushes Isi/Iso Ce Marked) , Dental Edta Gel (Specificatio- Edta 15% With Carbamide Peroxide Gel 10% Root Canal Preparation Gel, Syringes, 3Gm Each) , Dental Edta Solution (Specification- Root Canal Chelating Agent Used During Root Canal Treatment To Case Enlargement And Shaping Of Canal 15 - 18 % Edta Solution, Ce Approved (Prevest/ Prime Dental Rc)) , Dental Endodontic Absorbent Paper Points Size: 15-40 (Specification- • Should Be Color Coded And Correspond To Instrument Sizes • 2%, 4%, 6% Taper • Should Be Available In Both Individual And Assorted Packing) , Dental Glass Ionomer Silver Reinforced (Specification- Fda Approved Imported, Isi/Iso/Ce Marked Pack) , Dental Glass-Ionomer Cement (Oic) Type 2 (Specification- Radiopaque Glass Ionomer Restoration Material Imported Type 2 With Mixing Pad Matrix Strips And Spatula, Power / Liquid Fda Approved Imported Restorative Material Isi/Iso/Ce Marked (Gdc/3M/Dentsply/Similar)) , Dental Gloves (Specification- • Surgical And Disposable • 6,6 And Half ,7 Size • Latex And Vinyl ) , Dental Granulated, High Density Glass Ionomer Powder + Liquid For Filling Purpose. (Specification- Isi/Iso/Ce Marked, Granulated Glass Ionomer Powder To Provide Good Flow Ability For More Accurate And Reproducible Dosing. It Should Provide Case Of Handling (Faster And Easier Mixing) And Consistent Mixing, Used As A Base, Semi- Permanent Restorations, Core Buildups And Minimal Invasive Dentistry And A Traumatic Restorative Dentistry. Pack Of Powder+Liquid+ Mixing Pad +Scoop) , Dental Gutta Percha Points (All Sizes) In Separate Boxes Gutta Percha Individual Size 15,20,25,30,35,40,45,50,55,60,6570,75,80; 15-40 And 45-80 Each Pack Contains 100 Nos 28Mm Long Flat Ended Gp Points (Specification- • Isi/Iso/Ce Marked • Should Not Bend While Inserting • Should Not Be Brittle • Radio Opaque • Should Be Color Coded And Correspond To Instrument Sizes • 2% Taper • Should Be Available In Both Individual And Assorted Packing • Dentsply) , Dental Hydrogen Peroxide 3% 500Ml Bottle (Specification- Hydrogen Peroxide 3% 500Ml Bottle) , Dental K-Files 15-40 (21Mm,25Mm,31Mm) 45-80 (21Mm,25Mm,31Mm)Endodontic Files K-Files Size No.8,10,15,20,25,30,23.40,45,50,55,6 0,65,70,75,80 15-40 And 45-80 (Specification- • Stainless Steel Flexible Files • Isi/Iso/Ce Marked • Handles Should Be Color And Number Coded With Eye For Floss • Prefitted Silicon Stops • Should Be Available In 21Mm, 25Mm And 31Mm Lengths With 2%Taper • Should Be Available In Both Individual And Assorted Packing • 1 Pack Of 6 Files (Mani Files) , Dental La With Adrenaline (Specification- Lignocaine Hydrochloride And Adrenalin Injection 30Ml Im) , Dental La Without Adrenaline (Specification- Lignocaine Hydrochloride Injection30ml Im) , Dental Mineral Trioxide Aggregate (Specification- • Prevest • Bioceramic Material) , Dental Pedo Files (Hand Files And Rotary Files) (Specification- • Mani Files • K Files 18 Mm Size • Stainless Steel • Handle Should Be Color For Ease Of Identification • Designed For Bulk Removal Of Pulp Tissue • Pre-Sterilized In Individual Packing) , Dental Phosphoric Acid Etchant (Specification- 35% High Viscosity Phosphoric Etch, Ideal For Enamel Etching, Blue In Color For Easy Visualization And Contrast) , Dental Pro Taper Gp 21Mm, 25Mm,31Mm) F1,F2,F3 Gp (Specification- • Should Not Bend While Inserting • Should Not Be Brittle • Radio Opaque • Should Be Color Coded And Correspond To Instrument Sizes • 4%, 6% Taper • Should Be Available In Both Individual And Assorted Packing Dentsply) , Dental Pulp Devitalize (Specification- Isi/Iso/Ce Marked Imported) , Dental Radio Opaque Calcium Hydroxide Cavity Liner. -Paste Of Ca(Oh)2 Paste + Catalyst (Specification- Self-Curing Calcium Hydroxide Preparation For Use In Direct And Indirect Pulp Capping. Available As Pack Of Base And Catalyst Pastes (11 Gms, 13 Gms Respectively Each) With Mixing Pad, Ce Approved) , Dental Root Canal Disinfectant Consisting Of, Thymol, Dexamethasone (Specification- Root Canal Disinfectant Consisting Of Dexamethasone, Thymol, Chlorhexidine) , Dental Root Canal Sealer (Indomethacin) (Specification- Radio Opaque Sealapex Dentsplya, Endoseal, Ivoclar, Sybronendo) , Dental Rotary Files 21Mm,25Mm (Specification- • Stainless Steel Files And Flex Files • Isi/Iso/Ce Marked • Handles Should Be Color And Number Coded With Eye For Floss • Dentsply, Neoendo • Should Be Available In Both Individual And Assorted Packing) , Dental Sodium Hypo Chloride (Specification- Sodium Hypo Chloride- 5% For Dental Use 500Ml Liquid Bottle) , Dental Suction Disposable Tips (Specification- 100 Tips / Per Pack) , Dental Suture (Specification- • Silk, Monofilament, Vicryl, Cat-Gut, • 2-0,3-0,4-0,5-0 Size • Jhonsons Company, Ethicon • Reverse Cutting, Round, Cutting • 1/4Th , 3/4Th ,1/2Th ) , Dental Temporary Restoration Material (Specification- Ready To Use, Temporary Filling Material, Fluoride Releasing Moisture Activated Cavit) , Dental X-Ray Developer (Specification- Powdered Forms Should Contain 2 Kg In One Pack Isi/Iso/Ce Marked) , Dental X-Ray Film Digital , Dental X-Ray Film Size 31 X 41 Mm (150 Films / Pkt) , Dental X-Ray Film (Specification- I0pa Film Size 0 (2.2X3.5 Cm - Fuji Or Equivalent) (Should Contain 150 Nos. Of Films In One Pack) Isi/Iso/Ce Marked) , Dental X-Ray Film (Specification- I0pa Film Size 2 (3X4 Cm Fuji Or Equivalent) (Should Contain 150 Members Of Films In One Pack) Isi/Iso/Ce Marked) , Dental X-Ray Fixer (Specification- Powdered Form Should Contain: 2 Kg In One Packisi/Iso/Ce Marked) , Desirepoly Bag Colour Sutable Forapprox 35Ltr Dustbeen 55 Micron , Desire Poly Bag Colour Sutable Forapprox 10Ltr Dustbeen 55 Micron , Desire Poly Bag Colour Sutable Forapprox 60Ltr Dustbeen 55 Micron , Desired Bio Hezard Poly Bag Capacity Of 30 Ltr , Desired Bio Hezard Poly Bag Capacity Of 40 Lit , Desired Bio Hezard Poly Bag Capacity Of 50 Ltr , Desktop I3- 10Th Generation Intel® Core™ I3 Processor Windows 10 Home Single Language 64 4 Gb Ddr4-2666 Sdram (1 X 4 Gb) 1 Tb 7200 Rpm Sata Hdd , Desktop I5- 10Th Generation Intel® Core™ I5 Processor Windows 10 Home Single Language 64 8 Gb Ddr4-3200 Sdram (1 X 8 Gb) 1Tb 7200Rpm Sata , Desktop I7- 10Th Generation Intel® Core™ I7 Processor Windows 10 Pro 64 8 Gb Ddr4-2933 Sdram (1 X 8 Gb) 1 Tb 7200 Rpm Sata Hdd , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life - (5 Ltr Can To Make 22.5 Liters Working Solution) , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life-2 Lit Can( To Make 9 Liters Working Solution) (Bromodex Mp Developer Concentrate) 9Ltr Packing , Developer Single Bath Liquid Concentrated Of Consistent Quality. It Sould Have Favoutable Contrast/Fog Ratio And Good Shelf Life-3 Lit Can( To Make 13.5 Liters Working Solution) (Bromodex Mp Developer Concentrate) 13.5 Ltr Packing , Diagnostic Strips For Urine Sugar/Albmin Packing: Of 100 Strip/Pkt , Diamond Marke Pencil , Digital Clock Wall Standard Company , Digital Thermometer , Digital Wrist Watch , Digital X Ray Film (Pack Of 100)),Film Size4 Inch X 17 Inch D , Digital X Ray Film -10X12 (150 Films/Pkt) , Digital X Ray Film -11X14 (150 Films/Pkt) , Digital X Ray Film -8X10 (150 Films/Pkt) , Digital X-Ray Film Size 14 X 17(50 Sheet Per Packet) , Diluent M-30D-(20Ltr) , Dionised Water 5 Ltr Cane(Each), , Disinfectant Renaclean Cold Sterilant (5 Ltr Can) , Disinfectant Renasteril Hot Disinfectant (5 Ltr Can) , Disposable Appronpvc Full Size , Disposable Bed Sheet 60X96 , Disposable Cresent Knife(2.2Mm), , Disposable Cup For Urine-Sputum 30Ml 80 To 90 Mm Diameter 100/Pkt , Disposable Dust Mask - Jl246c Equivalent To N-95 Mask 100 Pcs , Disposable Laboratory Coat Large Blue Colour , Disposable Laboratory Coat Large White Colour , Disposable Laboratory Coat Medium Blue Colour , Disposable Laboratory Coat Medium White Colour , Disposable Vial 3Ml(Each) With Air Tide Cap , Distilled Water 5 Lit , Domestic Hut 8.5 X 6 X 13 , Door Matte Big Size Jooth (Sandard Quality) , Door Matte Big Size Plastic (Sandard Quality) , Door Matte Medium Jooth (Sandard Quality) , Door Matte Medium Plastic (Sandard Quality) , Drabkin Solution For Hb 5 Lit , Draw Sheet Bleach 45 X 45 , Dressing Drum (Made Of Ss) (Size:-11X9) Standard Qualtiy , Dressing Drum (Made Of Ss) (Size:-9X9) Standard Qualtiy , Dressing Drum Ss Size 11X15 Standard Qualtiy , Dressing Drum Ss Size 6X6 Standard Qualtiy , Dressing Trolley - Frame Work Made Of 1 Vertical M.S Pipe , Two S.S Shelves Over With S.S Railling On All Four Sides , The Trolley Fitted S.S Bucket And Bowl And Mounted On 4 Dia Castors.Over All Size 30Lx18Wx32H, Finish Pre Treated And Epoxy Powder Coated, Also Available In Complete S.S , Drill Sleev For 2.7 & 3.2 Mm Drill Bits , Droper 2Ml , Drug Trolley Emergency , Dry Mop Complete , Dust Pan , Dustbin Foot Operated Plastic, Size 10 Ltr, Isi Mark , Dustbin Foot Operated Plastic, Size 15 Ltr, Isi Mark , Dustbin Foot Operated Plastic, Size 20 Ltr, Isi Mark , Dustbin Foot Operated Plastic, Size 25 Ltr, Isi Mark , Dustbin Foot Operated Plastic, Size 30 Ltr, Isi Mark , Dustbin Foot Operated Plastic, Size 5 Ltr, Isi Mark , Dustbin Without Foot Operated Plastic ,Size 10 Ltr,.Isi Mark , Dustbin Without Foot Operated Plastic,Size 15 Ltr,.Isi Mark , Dustbin Without Foot Operated Plastic,Size 20 Ltr,.Isi Mark , Dustbin Without Foot Operated Plastic,Size 25 Ltr,.Isi Mark , Dustbin Without Foot Operated Plastic,Size 30 Ltr,.Isi Mark , Dustbin Without Foot Operated Plastic,Size 5 Ltr,.Isi Mark , Dustbin Without Foot Operated Steel, Size 10 Ltr,.Isi Mark , Dustbin Without Foot Operated Steel, Size 15 Ltr,.Isi Mark , Dustbin Without Foot Operated Steel, Size 5 Ltr,.Isi Mark , E.D.T.A. Vacunater With Needle(3 Ml),Consumable , Ecg Paper (Chemical Coated)(80Mmx 20 Mtr Each), , Ecg Paper (Chemical Coated)(80Mmx 20 Mtr Each),Consumable , Ecg Paper(Chemical Coated) 50Mm X 30 Mtr. Roll , Ecg Paper(Chemical Coated) 50Mm X 30 Mtr. Roll , Ecg Paper(Wax Coated) (50Mm X 30 Mtr, Roll), , Ecg Paper(Wax Coated) (50Mm X 30 Mtr, Roll),Consumable , Ecg Paper(Wax Coated) Heavy Quality 50Mm X 30 Mtr/ Roll , Ecg Paper(Wax Coated) Heavy Quality 50Mm X 30 Mtr/ Roll , Economical & Compact , Edta K3 Vial Each , Edta K3 Vial Each , Edta Powder(250 Gm),Consumable , Edta Solutions K3 (150 Ml) , Edta Solutions K3 (150 Ml) , Edta Solutions K3 (500 Ml) , Edta Vial With Safty Cap (2Ml.) , Edta Vial With Safty Cap (2Ml.) , Edta Vial With Safty Cap (2Ml.) Capsule , Ehrilichs Aidehyde Reagen (2X250 Ml),Consumable , Ehrilichs Aidehyde Reagen (2X250 Ml),Consumable , Electric Drill Set Man Man , Electric Geyser 10 Ltr Capacity Isi Marked , Electric Geyser 15 Ltr Capacity Isi Marked , Electric Geyser 20 Ltr Capacity Isi Marked , Electric Geyser 50 Ltr Capacity Isi Marked , Eletric Torniquet , Elisa Reader - 0.000-3.5 Abs Mesurent Range, 500 Test Programe & 10000 Result Store, Bichromatic Optic System With Plate Shaker, External Mouse For Easy Handing Large Touch Screen, Whole Plate Reading In Just 5 Sec , Elisa Reader & Washer Printer , Elisa Washer - 48 User Programmable Wash Protocoles, 8 Way/12 Way Manifold, Auto Calibration, Washes Flat Round & V-Bottom Well, Well Depth Detection , Empty Bottel 500Ml With Cap , Endotracheal Tube Internal With Radioopaque Line(Dia 2.5 Mm To 5 Mm, Each), , Endotracheal Tube, Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Standard 15 Mm Connector Sterile, Single Use Curved Shaped Blister Pack-Suiting The Shape Of Product(Size 4 , Each),Tube , Endotracheal Tube,Soft Cuff Towards The Distal End Kink Resistant Inflation Tube Murphy Eye At Distal End With Polished Smoothness Standard 15 Mm Connector Sterile, Single Use Curved Shaped Blister Pack-Suiting The Shape Of Product(Size 3),Tube , Endotracheal Tubes Size 7 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25Each), , Endotracheal Tubes Size 8 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each), , Endotracheal Tubes Size 9 Cuffed Should Have Low Pressure High Volume Cuff And Radio Opaque Blue(25 Each), , Enema Appratus 1000 Ml Stainless Steel And Rubber Connection Tube Standard Qualtiy , Enema Sodium 100 Ml (Sodium Acid Phosphate 10 Gm, Sodium Phosphate 8 Gm / 100 Ml) With Tube , English Plier , Examination Gloves Disposable Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile Medium , Examination Gloves Disposable Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile Small , Examination Gloves Disposable Made Of Natural Rubber Latex, Pre-Powdered, Non-Streile, Size:- Large , Executive Chair Foam With Leather Standard Company , Extractor For Radius Ulna Nailing , Exust Cooler Plastic Body Standard Size (Water Tank Cap.100 Liter) , Face Shield Protector Safaqi( ),Consumable , Factor Ix Deficient Plasma (Less Than 1%)(10X1 Ml),Consumable , Factor Vii Deficient Plasma ( Less Than 1%)(10X30 Ml),Consumable , Falcon Tube Plastic Contianers With Air Tight Cap , Falcon Tube Plastic Contianers With Air Tight Cap , Fauchets Reagents (125 Ml),Consumable , Featal Doppler , Female Reprodective System Complete , Field Stain A 500Ml , Field Stain B 500Ml , Filter For Complete Pulmonary Function Testing (Including Dlco) With Body Box(100 Filters Per Pack, Make- Medisoft Sa),Consumable , Filter For Complete Pulmonary Function Testing (Including Dlco) With Body Box(100 Filters Per Pack,Consumable , Filter Paper Sheet (Whatmann No 01) Pack Of 100 Sheets , Finite Pump Finish- Pre Treated And Epoxy Powder Coated , Fire Extinguisher Cylander Abc Powder Type 2 Kg Complete , Fire Extinguisher Cylander Abc Powder Type 4 Kg Complete , Fire Extinguisher Cylander Abc Powder Type 6 Kg Complete , Fire Extinguisher Cylander Abc Powder Type 9 Kg Complete , Fire Extinguisher Cylander Abc Powder Type Refling For Per Kg , Fire Extinguisher Cylander Abcd Type 2 Kg Complete , Fire Extinguisher Cylander Abcd Type 4 Kg Complete , Fire Extinguisher Cylander Abcd Type 6 Kg Complete , Fire Extinguisher Cylander Abcd Type 9 Kg Complete , Fire Extinguisher Cylander Abcd Type Refling For Per Kg , Fistula 16G, Single Sterilizedsingle Needle Packing , Fistula 17G, Single Sterilizedsingle Needle Packing , Floor Cleaning 1 Liter Isi Mark , Floor Cleaning 1000 Ml Isi Mark , Floor Cleaning 20 Liter Isi Mark , Floor Cleaning 5 Liter Isi Mark , Floor Cleaning Liquid Cleaning 5 Lit , Floor Duster , Floride Vial With Sp Pack Of 100 , Flouride Solution (Pot.Oxalate 5% Flouride 1%) Pack Of 150Ml , Flow Regulator (Dial Flow)(Each), , Foetal Doppler , Foetal Stethoscope , Foot Operated Sanitizer Ss With 1 Liter Botal With Disp. Pump , Foot Staire , Foot Step Double Steel Iron Standard Qualtiy , Forcepartery Sp Wells Cvd. 20 Cm/8” Standard Qualtiy , Forcepkocher Artery Cvd 8 “ Standard Qualtiy , Forcepkocher Artery Str 8 “ Standard Qualtiy , Forcep Allis Tissue 4 ?5Th20 Cm/8” Standard Qualtiy , Forcep Artery Mosquito Cvd 12.5Cm/5” Standard Qualtiy , Forcep Artery Sp Wells Cvd. 15 Cm/6” Standard Qualtiy , Forcep Dis Sectionplain Ss 17.5 Cm Standard Qualtiy , Forcep Dis Section Plain Ss 20 Cm Standard Qualtiy , Forcep Hysterectomystandard Qualtiy , Forcep Intestinalsize 16 Cm Standard Qualtiy , Forcep Intestinal Size 12.5 Cm Standard Qualtiy , Forcep Mousquito Str+Cvdsize: 12.5 Cm , Forcepsplain Size 10 For Dressing S.Steel , Forcepsplain Size 12.5 For Dressings.Steel , Forcepsplain Size 17.5 For Dressings.Steel , Forcepsteeth Size 15 For Dressings.Steel , Forcepsteeth Size 25 For Dressings.Steel , Forceps Plain Size 20For Dressings.Steel , Formaldehyde (Formalin)34% Acq 450 Ml Bottle , Formaldehyde 40% (Conc. Formaline)(1 X 5 Lit), Cen , Formalin Chamber Internal Trays Sterdization Size 21X8X8.5Standard Quality , Formalin Chamber Internal Trays Sterdization Size 21X8X8.5Standard Quality , Formoline Solution 450Ml , Freedge Domstic 165 Litre Standrad Company Isi Mark , Freedge Domstic 220 Litre Standrad Company Isi Mark , Fumigator , Gauze Swab/Pad 4 Layer 10Cmx10cm , Gauze Swab/Pad 6 Layer 10 Cmx 10 Cm , Gauze Swab/Pad 6 Layer 20 Cmx 20Cm , Generator Silent Disel 15Kvax12kv Dg Set Standrad Company Isi Mark , Generator Silent Disel 20Kvax16kv Dg Set Standrad Company Isi Mark , Glacial Acetic Acid (1 Liter), , Glacial Acetic Acid (2.5 Liter) , Glacial Acetic Acid (2.5 Liter),Consumable , Glacial Acetic Acid (500Ml), , Glass Slide 75Mm X 25Mm 1.1 Mm , Glass Slide 75Mm X 25Mm 1.35 Mm , Glass Slide With Isi Mark-At Least 75Mm X 25 Mm- Thickness At Least 1.1Mm,Detail Specifications-I-With Smooth Edges, Without Any Scrathtches. Ii-Glazed Glass.Iii-No Visual Or Chromatic Abbretions(50Slides/Packet), , Glass Test Tube 12 X 100 (Medium Size) Heavy Quality 100/Pkt , Glass Test Tube 12 X 75(Small Size) Heavy Quality 100/Pkt , Glass Test Tube 5 Without Edge [987879] , Gloter Aldhiygde Solution Packge 1 Ltr , Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 6 Inch / Pair(Pair),Surgical Material Disposable , Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 6.5 Inch / Pair(Pair), Disposable , Gloves B.I.S Specification Gloves, Surgical Rubber, Made Of Hypoallergic Latex 100%, Electronically Tested Sterilized 7 Inch / Pair , Gloves Isi Marked Surgical Rubber Hypoallergenic Latex 100% Powder Free 7 1/2 Inc Disposable , Gloves Isi Marked Surgical Rubber Latex 100% Powder Free 6 Inches Disposable , Gloves Isi Marked Surgical Rubber Made Of Hypoallergenic Latex 100% Powder Free 7 Inches Disposable , Gloves Latex Examination (Large) (100/Pkt)(Packet) , Gloves Latex Examination (Medium) (100/Pkt)(Packet) , Gloves Latex Examination (Small) (100/Pkt)(Packet) , Gloves Latex Examination No.8 (100/Pkt)(Packet) , Gloves Postmartam 10 Pack , Gloysine Board , Glucometer Cell , Glucometer Sprips (1X100) , Glucometer Strips 1 Should Be Able To Use Capillary Blood Samples 2 Should Have Expiry As Printed On The Label Of The Supplied Box(3 All Strips Should Have At Least One Year Expiry Date From The Date Of Supply 1 Glucometer Free With Each 1 Thousand Strips Rate Should Be Quoted For , , Glucose Kit (God/Pod)(350Ml),Digonstic , Glutaraldehyde Solution 2% In 1 Litre Can (2 Strips/Vials Per Each Can)(1 Litre Can)] , Glutaraldehyde Solution 2% In 5 Litre Can (2 Strips/Vials Per Each Can)(5 Litre Can)] , Gram Iodine (Gram Stain) 125 Ml , Grasper- Laparoscopic 5Mm Straight 360 Degree Rotating With Insulated Shaft, Toothed A Traumatic Grasper With Ratchet Mechanism, Plastic Grip(36 Cms Length, Independently Moving Jaws),Consumable , Gynec Sheet 80 X 48 Standard Pvc Quality , Gypsona 4” , Gypsona 6” , Haemoglobin Pippate , Haemoglobin Tube , Haemoglobino Meter (Sahilmathard) , Half Volume Pt And Aptt Testing , Hand Drill , Hand Sanitizer With Pump(500Ml),Bottle , Hand Wash Liquid Cleaning Standard Company , Hand Wash Solution With Dispenser 500 Ml , Hb Colour Scal Book , Hbnc Kit Complete - Digital Wrist Watch1 Digital Thermometer 1 Nenatal/Infant Weighing Scale With Sling1 Warm Sleeping Bag For Neonates 2 Blankets For Neonates 3 Mucus Extractor2 Baby Feeding Spoon1 Torch With Cells1 Spoon1 Bag For Carrying Kit/Material During Home Visit1 , Hbsag Antigeng Kit Card(Pack Of 10 Card Test With 10 Dropper, 1 Buffer Solution, 10 Pricking Lancet And 10 Alcohol Swab),Digonstic , Hcl (1X500 Ml = 500 Ml), Conc , Hcl 35-37, 500 Ml Pack , Hcl N/10 (500 Ml Bottle) , Hcv Kit Card Test(25 Test Kit Pack), Digonstic , Hcv Rapid Test Card Single Test (J Mitra/ Span/ Tulip) , Heavy Duty Beam Rack For Ware House , Hemotocyto Meter, , H-Files 15-40(21Mm,25Mm,31Mm) 45-80 (21Mm,25Mm,31Mm) Headstrom Files (H-Files) Size No.15,20,25,30,35,40,45,50, 55,60,65,70,75,80 15-40 And 45-80 (Specification- • Stainless Steel Flexible Files • Isi/Iso/Ce Marked • Handles Should Be Color And Number Coded With Eye For Floss • Prefitted Silicon Stops • Should Be Available In 21Mm, 25Mm And 31Mm Lengths With 2% Taper • Should Be Available In Both Individual And Assorted Packing • 1 Pack Of 6 Files , Hiv 1&2 Test Cards , Hiv 1+2 (Rapid) Per Card , Hiv Rapid Test Card Single Test (J Mitra/ Span/ Tulip) , Hohmann Retractor , Hoilow Mill , Hole Towel Eye Drape (Size-70*70Cm Area 08*08) , Hooks For K Nail Retractor , Hospital Bed Powder Coted Size 84Lx36Wx24H , Hospital Bed Ss 6X3x2.5 With Mattress 6X3x4 , Hot Water Bag Isi Mark Standard Company , Hub Cutter- Non Electric Lockable Safety Portable Box For Disposal Of Hypodemic Needles. , Hydrogen Peroxide (Conc.) H2o2 (500 Ml), , Hydrolic Ot Table , I.V Set (Child) With Airway And Needle Standard Company , I.V Stand Powder Coted 4 Legs Base , I.V Stand Ss 4 Legs Base , I.V.Set (Adult) With Airway And Needle Standard Company , Ice Gel Pack 200 Gm , Ice Gel Pack 500Gm , Id Wrist Band(Identification For Mother/Child Specific Colour)(Wrist Band/No), , Incubater B.O.D , Incubator , Indicator Sol, For Ph (Litmus Sol) (1X500 Ml = 500 Ml) , Infant Feeding Tube (Catheter)(10 G, Each), , Infant Feeding Tube Size: 10G , Infant Feeding Tube Size: 3G Catheter , Infant Feeding Tube Size: 4G Catheter , Infant Feeding Tube Size: 5G , Infant Feeding Tube Size: 6G , Infant Feeding Tube Size: 7G , Infant Feeding Tube Size: 8G , Infant Mucus Extractor Sterile Pvc(Each),Surgical Material , Infant Weing Scal With Bag , Infantometer , Infrared Hemoglobin Meter Isi Company , Infusion Pump Features :- Front Load Of Yringe , Automatic Detection Of Syring, Bolus And Purge Facilty , Self Illutrative Contorl Panel , Syring Capacity , 10Ml-300Ml/Hr.20Ml-500Ml/Hr , Instrument Tray Ss With Cover 10X8 Standard Company , Instrument Tray Ss With Cover 15X12 Standard Company , Instrument Trays With Cover Size: 10 X 12 Standard Company , Instrument Trays With Cover Ss Size: 7 X 11 Standard Company , Instrument Wash Solution 500Ml With Spray Pump , Insulated Container , Intracath Cannula For Single Use (Intravascular Catheters) Bis(Gauze 22, Length 25), , Inverter Battery 500 Watt 150 Ah Isi Mark , Inverter With Battery 1000 Va [One Battery Required]Isi Mark Standard Companywith Installation , Inverter With Battery 1500 Va [Two Battery Required]Isi Mark Standard Companywith Installation , Iron Box 5’X2.5’X2.5’’ , Iron Box 6’X3’X3’’ , Iron Lock Standard Size , Iron Stand With Belding Work , Isopropyl Alcohol (Propanol)(1 X 2.5 Lit), , Iv Cannula Size With Injection Valve (18G ) , Iv Cannula Size With Injection Valve (22G ) , Iv Cannula Size With Injection Valve (24 G) , K Wire (Length 375Mm Size:1.6Mm Roll) , K Wire (Length 375Mm Size:1.8Mm Roll) , Kangaroo Mother Care Gown Design (Kmc) Stared Size Cotton , Keratom Knife(2.8Mm), Disposable , Keratome 3.2 Keratome Round Stock 3.2Mm Full Handle Knives E.T.O. Sterile Angled Bevel Up 45 Deg(), , Key-Board (Tvs/Cherry) , Key-Board Standard Quality Repudate Company , Kmc Chair We Klm Healthcare And Equipments Deals In All Hospitals Furniture. We Are Leading Manufacturers In Hospital Furniture And We Deals In Mild Steel, Stainless Steel And Aluminium Hospitals Furnitures. We Have Wide Range Of Products With Quality Of Material And With Good Price Range. We Also Deal In Hospitals, Icu And Clinic Furnitures..Like Fowler Beds, Electric And Manual And Stretcher And Trolley And Bed Side Lockers,Dustbins,Stool Beds..You Can Contact Us Via Mobile, Sms And Mails. , Knife Blade All No Pack Of 100 , Konika Minolta Photocopier Presser Roller , K-Wire Bender Steel , K-Wire Cutter Medium , Lab Coat , Labour Room Fumigation Solution Preparation Labour Room Measurement 16(Wt)X23(L)X12(Ht)=4416 Cubic Ft 0.01% Silver Nitrate 10% Hydrogen Peroxide 20% Solution =754 Ml 80% Water =3662 Ml Total Prepared Solution =4.416 Liters , Labour Room Tray 12”X10” , Labour Room Tray 12”X10” , Labour Room Tray 15”X12” , Labour Room Tray 15”X12” , Labour Table 3 Fold Ss With Foam Mattress, , Labour Table Hydraulic , Labour Table Manul , Laptop Charger/Acer/Lenovo,/Lg/Acer/Dell , Laptop Dell/Hp/Aser/Asus/Lenovo Company I3 , Laptop Dell/Hp/Aser/Asus/Lenovo Company I5 , Laptop Dell/Hp/Aser/Asus/Lenovo Company I7 , Larrynoscope Set With Four Blades (Adult) , Larrynoscope Set With Four Blades (Infant) , Larrynoscope Set With Four Blades (Paediatric) , Laser Printer , Lcd Projector (Multimedia Lcd Projectors. Our Offered Projectors Are Widely Used In Various Business Meetings, Events, Conferences, Presentation And Other Exhibition Shows. These Projectors Are Widely Acknowledged By Our Clients For Their User Friendly Settings And Hassle Free Operations. The Provided Projectors Are Precisely Manufactured At Our Vendors End Using The Modern Technology.) , Lcd Projector Brightness 3000 Lumens (2100 Lumens Eco Mode) Projection Distance 1.94M - 4.85M (3.23M To 3.55M For 100 Focal Length F 2.56 To F 2.8/ F - 21.0 To 23.1 Mm Lamp Type 190W P-Vip Native Resolution 180 X 800 (Wxga), 1024000 Pixels Video Formats 1080P / 1080I / 720P / 576P / 576I / 480P / 480I Screen Size 60 - 150 (129 X 81Cm - 323 X 202Cm) Imaging Technology 1.1 X Manual Type Reflective Dlp Chip Size And Number 0.65 Diagonal, Single Chip Projection Ratio 1.501 To 1.651 , Led 15 Standard , Led 17 Standard , Led 21 Standard , Led 23 Standard , Lenz Bone Holding Forcep , Liquid Paraffin 50Ml(Bottle ) , Liquor Ammonia (500 Ml),Consumable , Long Body Suit -Non Woven Fabrie , Long Line Silicon Catheter, G-24, Fr-2, L-30Cm , Low-Profile Titenium Chemo Port With Cilicon Catheter (9.6 Fr, 6.6Fr, 3.9Fr,) Length -60Cm,Guide Wire, Peel-Away Desilet,Hubsite Needle(22G*20Mm) , M-30-D-Diluent(20Ltr),Consumable , M-30-R-Rinse(20Ltr),Consumable , Macconckeys Agar(500Grm),Consumable , Macconckeys Agar(500Grm),Consumable , Mackintosh Double Colour Water Proof Rubber Marked Isi Hospital Rubber Sheeting Is:4135-1974 Packing And Making : As Per Clause No 4.1 And 4.3 / Mtr , Malaria Antigen Pv/Pf Single Test , Male Reprodective System Complete Standard Company , Malleable Splirls (X-Ray Through The Splints Fixing Of Splint Is By Zipper Or Belt Distal End Left Open To Expose Toes Should Be Washable And Reusable) , Mammanatallie Standard Company , Mammanatallie Standard Company , Manometer And Flo Meter For Oxygen Cylinder , Manometer And Flo Meter For Oxygen Cylinder , Maryland Dissector- Laparoscopic 5Mm Curved Maryland Dissector With Tapering End, 360 Degree Rotating With Insulated Shaft, Non Ratchet , Plastic Grip(36 Cms Length, Monopolar Pin Provision For Usage With Electro Surgical Unit, Independently Moving),Consumable , Mattres Cover Complete Size L.6.5Fxw3.5Fxt5.5F Inch , Mattress Coir With Foam Topping Plain Cloth Cover Size 72X36x4 Thik With Ragzine Cover , Medical Nitrous Oxide Gas In Jambo Size Cylinder(D Type),Miscellaneous , Medical Nitrous Oxide Gas In Medium Size Cylinder(B Type),Miscellaneous , Medical Nitrous Oxide Gas In Small Size Cylinder(A Type),Miscellaneous , Medical Oxygensteel /Aluminium Cylinder (10 Litres Water Cap) With Gas Specific Pin System(10 Liters),Inhalation , Medical Oxygen Gas Ip In Jambo Size Cylinder(D Type),Miscellaneous , Medical Oxygen Gas Ip In Medium Size Cylinder(B Type),Miscellaneous , Medical Oxygen Gas Ip In Small Size Cylinder(A Type),Miscellaneous , Medical X-Ray Film-Polyester Based Imaging Film 30.5 Cm X 30.5Cm (12X12) Size:- 50 Sheets In One Packet , Medical X-Ray Film-Polyester Based Imaging Film 35.6 Cm X 43.2Cm (14X17) Size:- 50 Sheets In One Packe , Medical X-Ray Film-Polyester Based Imaging Film 35.6Cm X 35.6Cm (14X14) Size:- 50 Sheets In One Packet , Medigard Hand Scrub , Messuring Cylinder 1Ltr With Spout , Mesuring Cylinder Pack Of 100Ml , Mesuring Cylinder Pack Of 1Lit With Spout , Mesuring Cylinder Pack Of 500Ml , Methanol(Acetone Free) For Leishman Staining (1X2.5Lit) , Methanol(Acetone Free) For Leishman Staining (1X2.5Lit) , Methnol , Methylate Spirit (Sep.Chemical Name Ethanol Denatured+5% Isopropyl Alcohol+5%Methanol, Molecularstructure : C2h50h Molecular Wt: 46.07 Purity : 90% , Methylene Blue 25Gm Dye Content 82% , Methylene Blue Pack Of 500Ml/Gram (Dye Content+42% Sepc.Chemical Name: Methylthionine Chloride, Chemical Structure: C16h18c1n3s,Molecular Wt: 319.9, Dye Content: Approx 82% (Should Be Available On The Container) , Micro Drip Set , Micro Pipet 1000 Fix And Variable Each , Micro Pipet 100-1000 Fix And Variable Each , Micro Tips Big Pack Of 500 Pices , Microalbumin Urine(100 Tests) , Micronthik Bag 10 Lit. , Micronthik Bag 10 Lit. , Micronthik Bag 30 Lit. , Micronthik Bag 30 Lit. , Micronthik Bag 5 Lit. , Micronthik Bag 5 Lit. , Micronthik Bag 50 Lit. , Micronthik Bag 50 Lit. , Micropiptte 100-1000 , Microscope With Digital Display And Having Magnification , Microsurgery Speciality Gloves(Size 6.5),Lens , Microtips (2-200 Ul) 1X1000(Each), , Milkiwhitegel Based Sanitizer1.Ethinol (Cas-64-17-5) 58-62% 2. Benzoil Coline Chloride 0.52% 1 % 3. Ph Neutral Contact Time 15 Sec 4.(Pack Size L& 500 Ml With Dispensor), , Mobile Operating Light Double Dom Isi Mark Standard Company , Mobile Operating Light Four Dom Isi Mark Standard Company , Mobile Operating Light Single Dom Isi Mark Standard Company , Mobile Operating Light Three Dom Isi Mark Standard Company , Mopping Pad , Motorized Ot Table With Chair For Ophthalmology , Mouth Gage , Mtp Cannulas Standard Company , Mva Kit (Mannual Vaccum Aspiration Kit) , N-95 3M Disposable Raspirator(Without Valve Ffp2), , N-Acetyl L-Cystein , Nah2 Po4 (Anhydrous) Analar / Gr/Ar (1X500 Gm = 500Gm), , Naphthalene Balls , Nasal Prongs Catheters Child Size Disposable , Nebulization Mask - Kit (Pediatrics) , Nebulize Compressor. Piston Model, Fitted With Small Fan, Nices Less 60 Decible, Nebulizer Chamber Autoclave, Particle Size Between 0.5 To 5 Micron Suitable For Adult And Pediatric Patient. Resptrable Particle Above 60, Tor 300 Mg/Min , Needle And Syringe Destroyer Electrically Operated , Needle And Syringe Destroyer Manually Operated , Needle Holder Laparoscopic 5Mm Straight Reusable Needle Holder With Ratchet Mechanism With High Quality Tungsten Plated Jaws For Enhanced Needle Grip(36 Cms Metal Shaft), , Needle, 24G Surgical Material Disposable , Needles 22G Disposable , Needles 23 No Disposable , Needles 26G X 1/2 Disposable , Neonatal Infant Weighing Scal With Sling , Nibp (Non Invasive Blood Pressure) Multi Channel Monitor) , Nitric Acid (Hno3) (2.5 Liter), Con. , Nitrous Oxide Gas In Jambo Size Cylinder(D Type) , Nitrous Oxide Gas In Medium Size Cylinder(B Type) , Nitrous Oxide Gas In Small Size Cylinder(A Type) , Non -Contact Rapid Temperature Measurment System-Screen 2.8 Inch Tft Screen, Infrared Resolution Size 160X120, Frame Rate 9Hz, Temperature Measurment Range 30 Dig.C-45Dig.C, Accuracy + 0.5Dig.C, Distance 1M. Measuring , Storage - Take And Store Photos To Sd Card , Software Pc Analysis Software, Battery - Rechargeable 3.7V/5000Mah Lithium Battery. 22650 Single Cell, Battery Working Hrs- Up To 6Hrs.To Escort Your Continucous Work, Weather Proof, Nycocard Reader -Up To 2M, Tripod Mounting Hole 1/4 Inch, Hba1c, Microabumin, D-Dimer, C-Reactive Proteins , Non -Invasive Ventilaor (Sponteneous And Timed) , Nylon Suture Spatulated Micropoint Reverse Cutting Needle, Double Armed Suture Size 9-0(12 Foils/Pkt),Suture , Obsteric Labour Talbe Mechacally :- Sep- Frame Work Made Of Heavy Ms Crca Tubular Pipe.Stainless Steel Top In Two Section , Back Rest Section Adjustable On Retched System, Trendleburg Position Adjustable On Screw Mechanism By Handle. Supplied With Waste Collecting , S.S Bowl On S.S Bracket And I.V Rod , Height Adjustable A Pair Of Leg Holders With Straps, Complete With Self Locking Traction Handle I.V Rod , Overall Size 72 Lx27Wx30H Cms.Finish Pre Treated And Epoxy Powder Coated.Also Available In Complete S.S , Oil Room Heater 15 Fins 2900 Watts , Oil Room Heater Ofr 13 Fin Ofr (Oil Filled Radiator)| Room Heater| 2900 W| 3 Thermostatic Heat Power Settings & Ptc Fan Control| Long-Lasting Heat| Comfortable Breathing| Uniform 360° Heating (Black) , Oil Room Heater Ofr 9 Fin Plus 2000W Oil Filled Room Heater For Home|Easy Breathing*| Duraprotek-Anti-Leak Fins|3-Yr Warranty400w Ptc Ceramic Fan Heater|3-Heat Setting-1000W/1500W/2500W|Black,2400 Watts , Operating Microscope For Ent (Imported) , Ophthalmo Scope Direct , Ophthalmo Scope Direct , Ophthalmo Scope In Direct , Ophthalmo Scope Indirect , Orthopaedic Speciality Gloves(Size 7),Consumable , Orthopaedic Speciality Gloves(Size 7),Consumable , Osteome Medium , Osteotome Large , Osteotome Small , Oxalic Acid , Oxygensteel /Aluminium Cylinder (10 Litres Water Cap) With Gas Specific Pin System(10Liters),Inhalation , Oxygen Conentrator , Oxygen Cylande Refling Jumbo Large , Oxygen Cylande Refling Medium , Oxygen Cylande Refling Small A Type , Oxygen Cylinder (It Should Be A Standard ‘J’ Type Molybdenum Steel Cylinder To Fill Medical Oxygen The Capacity Should Be Of 5000 To 6000 Liters (5To6m3) At A Pressure Of 1800- 2000Ibs/Inch2, A Pressure Regulator Capable Of Reducing The Pressure To Appropriate Level To Run Either A Ventilator Or Provide Oxygen Therapy With A Flow Meter Should Be Provided , Oxygen Cylinder (It Should Be A Standard ‘J’ Type Molybdenum Steel Cylinder To Fill Medical Oxygen The Capacity Should Be Of 5000 To 6000 Liters (5To6m3) At A Pressure Of 1800-2000Ibs/Inch2, A Pressure Regulator Capable Of Reducing The Pressure To Appropriate Level To Run Either A Ventilator Or Provide Oxygen Therapy With A Flow Meter Should Be Provided , Oxygen Cylinder Flow Meter , Oxygen Cylinder Gauge Valum , Oxygen Cylinder Gauze-1 , Oxygen Cylinder Gauze-2 , Oxygen Cylinder Jumbo Size Complete Set , Oxygen Gas Ip In Jambo Size Cylinder(D Type) , Oxygen Gas Ip In Medium Size Cylinder(B Type) , Oxygen Gas Ip In Small Size Cylinder(A Type) , Oxygen Humidifier , Oxygen Inhelation Mddial Oxygen Steel Aluminium Cylinder 10 Ltr , Oxygen Mask Adult (Standard Size) Standarad Company , Oxygen Mask Paediatric (Standard Size) Standarad Company , Paper Adhesive Microporous Surgical Tape 1 Inch X 9 M / Roll (10 Roll/Pkt) , Paper Adhesive Microporous Surgical Tape 1/2 Inch X 9 M / Roll (10 Roll/Pkt) , Paper Adhesive Microporous Surgical Tape 2 Inch X 5M /Roll , Paper Adhesive Microporous Surgical Tape 3 Inch X 5 M / Roll (10 Roll/Pkt) , Paper Adhesive Microporous Surgical Tape 4 Inch X 9 M / Roll , Paper Adhesive Microporous Surgical Tape 6 Inch X 10 M / Roll , Paper Gloves Size 7 Inchesdisposable , Paper Gloves Size 7,1/2 Inchesdisposable , Paraffin Strips , Pasteur Pipette Individually Packed Sterile 3Ml , Patch Buprenorphine(10Mcg),Consumable , Patch Buprenorphine(20Mcg),Consumable , Patella Holding Forcep Large , Patella Holding Forcep Small , Patient Gown Pvc Standard Size , Patient Gown Standard Size , Patient Stool Standard Size , Pcr Tube 0.2 Ml , Phenyl - As Per Schedule O (Grade 1) 10 Lt Jar(Isi Marked) , Phenyl - As Per Schedule O (Grade 1) 20 Lt Jar(Isi Marked) , Phenyl 40% /Phanolic Solution 40% 20 Lte. , Phenyl Crystal 1000 Ml Purity 99.5% , Phenyl Crystal 500Ml Purity 99.5% , Photo Calorimeter , Photo Therapy Unit Double Surface , Photocopier Machine A-3 Size (Canan India 2006N) , Photocopier Machine A-3 Size (Konica Minolta) , Phototherapy Unit , Pipete Graduated 0.2Ml , Plain Disposable Vial 3Ml(Each),Consumable , Plain Vial With Screw Cap (12 X 75), , Plain Vial With Screw Cap (12X75),Consumable , Plaster Of Paris Bandage 10 Cm X 2.7 Mtr / Roll(Roll),Bandage , Plaster Of Paris Bandage Bp 15 Cm X 2.7 Mts/Roll Standard Company , Plaster Of Paris Pack Of 5Kg , Plastic Bags 18X16x8 , Plastic Bottle(1000 Ml), Empty With Cap , Plastic Bottle(300Ml), Empty With Cap , Plastic Bottle(500 Ml), Empty With Cap , Plastic Box Supirior Quality 10X7x4 , Plastic Box Supirior Quality 9X3.5’X3’ , Plastic Box Supirior Quality 9X6’X6’ , Plastic Box Supirior Quality 9X6x4 , Plastic Bucket Black 20 Ltr , Plastic Container With 2Lt Cap , Plastic Tanki 1000 Ltr. For Water (3 Layerd, Standard Quality, Manu.By Reputed Company) , Plastic Tanki 500 Ltr. For Water (3 Layerd, Standard Quality, Manu.By Reputed Company) , Plate Holding Forcep Large , Plate Holding Forcep Medium , Plate Holding Forcep Small , Pneumatic Tourniquet , Poe 16 Channel , Poe 4+2 , Poe 8+2 , Poly Bag Black 16X18 Cap. Of 5 Kg Weight , Poly Bag Red 16X18 Cap. Of 5 Kg Weight , Polymed High Pressure Extension Tube, Length - 100Cm , Polymed High Pressure Extension Tube, Length - 150Cm , Polymed High Pressure Extension Tube, Length - 200Cm , Polymed Size - 1, (12 Foils/Pkt)(1/2 Cir Rb Needle 45 Mm, Length 90 Cm ),Needle , Polymed Size-2/0 (12 Foils/Pkt)(1/2 Cir Rb Needle 25Mm, Length 45 Cm),Needle , Polythine Whit Standard Quality(Weghting Capicty 10 Kg To 20Kg) , Poocha Long Cloth Standar Size , Portable Fogging Machine , Postmartem Gloves , Postmartem Set , Postmartem Set , Potassium Permanaganate , Pptubes For Centrifuge 50 Ml , Pregnancy Detection Kit Ce Marked/Isi Marked 30 Test/ Kit , Pregnancy Test Strips For Urine Pack Of 100 Strips , Pregnant Stage And Reprodective Dumy , Pricking Lancet (Pkt Of 200 Units)(Packet), Disposable , Pricking Lancet 100 Units Disposable , Printer Canon Lbp 2900B , Printer Colour Hp/Canon/Epson , Printer Epson L380 , Printer Epson M 200 , Printer Hp 1005 , Printer Hp 1020 , Printer Laser Printers: Monochrome, 600X600 Dpi, A4, 14Ppm, Usb,-(Each , Printer Lasesr: Colour, 600X600 Dpi, A4, 8 Ppm Bw& Ppm Colour(A4 Size), 16 Mb- (Each) , Printers Laser: Canon, 600X600 Dpi, A4, 14Ppm, Usb,-(Each) , Pro Taper Files Set Of 6 15-40 (21Mm,25Mm,31Mm) (Specification- Dentsply Set Of (21Mm,25Mm,31Mm) • Should Be Available In Both Individual And Assorted Packing •1 Pack Of 6 Files • Handles Should Be Color And Number Coded With Eye For Floss • Stainless Steel Files) , Pulse Oximeter Finger Tip , Pulse Oximeter Table Top , Punefure Proof Container , Purified /Distilled Water- Laboratory Grade , Pvc Carpet , Pyrethrum Extract 2%(25 Litre Drum) , Ra Factor 25 Test Kit Qualicative , Ra Factor 50 Test Kit Qualicative , Rbc Dialuation Fluid (500 Ml Bottle) , Reamers For Radius Ulna Nailing , Rectal Thermometer , Refrigrator 322 Liter , Resusciatation Set With Infant & Neonatal Mask , Retinoscope , Retractor Right Angle Large , Retractor Right Angle Medium , Retractor Right Angle Small , Revolving Stool 4 Leg Ss , Rib Belt Large(Mfg By - Precious Life Care) , Rib Belt Medium(Mfg By - Precious Life Care) , Rib Belt Small(Mfg By - Precious Life Care) , Rna Extraction Kit - Icmr Certified Kit(250 Test) , Road Broom With Handle , Rolled Bandaze 10 Cm X 5 Mtr. , Rolled Bandaze 15 Cm X 5 Mtr. , Rolled Bandaze 5 Cm X 5 Mtr. , Rolled Bandaze 7.5 Cm X 5 Mtr. , Room Heater Hot Air Blower 2 Kw , Room Spray , Ryles Tube (Pvc) Size : Adult16-18 ) , Ryles Tube (Pvc) Size : Children: 10-12 , Ryles Tube(Size 14 Each Piece) , Salt Testing Kit(As Per Attached Specification , Kit), , Sanitary Napkins Pack Of 6 Pc Standred Size , Sanitizer With Dispenser 100 Ml , Sanitizer With Dispenser 500 Ml , Scalp Vein Set Size 20 No Disposable , Scalp Vein Set Size 22 No(Each), Disposable , Scanner Canon Lide 110/Standard Company , Scanner Canon Lide 120 , Scessior Stainless Steel 8: , Scessior Stainless Steel 9: , Scissor Dressing Str/Cur Ss 12.5 Cm , Scissor Dressing Str/Cur Ss 15 Cm , Scissor Dressing Str/Cur Ss 17.5 Cm , Scissor Mayo Str/Cur Ss 16 Cm , Scissor With Round Trap , Scissors Str + Cvd Size 10 Cm Cutical , Scotch Bright , Screw Driver For 3.5 Mm Screws , Seenk Jhadoo (Standard Size) , Seman Diluting Fluid 100 Ml. , Sencer Senitizer , Senstivity Disk , Serological Water Bath With Digital Temprature Display Size 605X300x150mm , Shadowlessceiling Light: 28 Dome With Seven Reflector Each Fitted With A Halogen Bulbe And Spherical Filter Glass Ensuring Shadow Free Corrected And Cool Light With A High Intensity Of Illumination (Major Ligh Of 1,20,000 Lux And Satelite Of 75000 Lux , Sharp Collection Containers 1.5 L Disposable , Sharp Collection Containers 5 Ltr Disposable , Sideport Knife(Num), , Sideport Sics Blade (Sideport Entry Knife), , Single Umbilical Catheter With Leur Lock(Fr-3 To Fr 3.5 , L-40 Cm),Consumable , Single Umbilical Catheter With Luer Lock Stopcock Fr-2, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-3, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-4, L-40 Cm , Single Umbilical Catheter With Luer Lock Stopcock Fr-5, L-40 Cm , Slide Box Plastic Cap 100 Slide , Slide Box Plastic Cap 50 Slide , Slide Box Wooden Cap 50 Slide , Slide Holder (Made For Metal) , Slide Rack (Metal) For 25 Slides , Slide Stain Horigontal Cap 50 Slide , Slide Stain Vertical Cap 50 Slide , Slit Lamp With Stand , Snellens Vision Box Roted , Sodium Citrate 3.8% - 500 Ml , Sodium Hydroxide (Naoh) (Analar / Gr/Ar) (1X500 Gm = 500Gm), , Sodium Hypochlorite 5% Solution(5 Ltr),Solution , Sodium Hypochlorite Solution 100 Ml Bottle , Sodium Hypochlorite(0.03/5 Ltr),Solution , Sodium Nitroprusside (100 Gm), [710034] , Soft Board 3X4 With Cover , Soft Board 4X5 With Cover , Soft Roll 4” , Soft Roll 6” , Solar Inverter 850 Kva. Double Bettery Syestem. , Solar Led Street Lightning System Along With Mounting Pole , Spaculam , Spinal (L.P.) Needle Disposable 24G , Spinal (L.P.) Needle Disposable 26G , Spinal (L.P.) Needle(25G),Surgical Material Disposable , Spinal Needle 18 No. Disposable , Spinal Needle 22 No. Disposable , Spinal Needle 23 No. Disposable , Spinal Needle G-22 L-120 Mm*0.71/Piece , Spinal Needle G-23 With Metal Stylet. , Spinal Needle G-27 L-120 Mm*0.40/Piece , Spine Board (Should Be In Plastic Material At High Strength And Waterproof. It Should Be 4 Rules For The Quick And Total Fixing Of The Head Immobilizer And Two Cavities Waherthe Board Lays On The Floor.When The Base Is Blocked In The Traditional Way, That Allow A Avoid Damaes Of Rip-Off Straps During The Usage Of Accommodation In The Ambulance It Should Be Handles For The Transport, Supplied With 3 Belts With Rapit Unhooking Buckle Should Have Maximum Radio Transparemcy To Make Exams Without Compromise Patient Condition.) , Sponge Holding Forceps , Spreader 15-40 (21Mm,25Mm,31Mm) (Specification- • Nickel Titanium Files • Isi/Iso/Ce Marked • Handles Should Be Color And Number Coded With Eye For Floss • Prefitted Silicon Stops • Should Be Available In 21Mm, 25Mm • 2 % Taper • Should Be Available In Both Individual And Assorted Packing • 1 Pack Of 6 Files) , Spring Balance Capacity 15 Kgs (For Baby Weighing) , Spuum Containersep.(Cups Made Of Special Medical Grade Polypropylene, Thin Plastc, Transulucent, Diameter- 4Cm,Capacity-30Ml, Srewable Cap Should Also Be Made Of Special Medical Grade Polypropylene And Should Be Air Tight. Leak Proof. Pack Of 100 Pc , Stabilizer For Ac , Stain (1X25 Gm = 25 Gm),Consumable , Stainic Rack(Each),Consumable , Staining Kit Reticulin(100 Test),Consumable , Staining Rod Steel (60Cm) , Stainless Steel Wire 30G , Stainless Steel Wire 30G , Steam Stock System & Mositure Trap , Steel Drill Bits 2.7Mm 3.2Mm 3.5 Mm Steel , Steel Hammer Heavy , Steel Troch With 3 Cell , Steel Troch With 3 Cell Isi Mark , Sterilant Cold Disinfectant For Dialysis Containing Peracetic Acid Hydrogen Peroxide Acetic Acid(5 Ltr Can),Consumable , Sterilant Hot Disinfectant For Dialysis Containing 21% (Approx) Citric Acid, Malic Acid, Lactic Acid(5 Ltr Can),Consumable , Sterlizer Electrically Operated (Size 10X5X3) Isi Marked , Sterlizer Electrically Operated (Size 12X6X4) Isi Marked , Sterlizer Electrically Operated (Size 8X5X3) Isi Marked , Sterlizer Electrically Operated With Automatic Cut Off Ss 12X6X4 , Sterlizer Electrically Operated With Automatic Cut Off Ss 20X6X4 , Stethescope Super Quality , Stethoscope Litman Type , Stop Watch Digital , Strecher Folding Cloth Standred Quality , Stretcher Trolley 4 Wheel 79X24X30 Without Handle , Stretcher Trolley 6 Wheel 79X24X30 Without Handle , Strip For Albumin Urine And Suger , Strip For Malaria Antigen, P Vivex, P Falciparum , Suction Machine Portable Electric , Sulphosalicylic Acid 3% W/V Pack Of 500Ml , Sulphuric Acid ( H2so4, Molecular Wt.98.08, Minimum Assay: 98% Colour: Clear , Surface Disinfectant 10 Minute Aldehyde Free Disinfectant Containing Potassium Mono Per Sulphate Powder((5Kg Packet)),Powder , Surgeon Cap(Box Of 100 Caps) Disposable , Surgical Blade Isi Marked, Size 11(100 Per Packet),Surgical Material , Surgical Blade Isi Marked, Size 15(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 22(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 23(100/Pkt),Surgical Material , Surgical Blade Isi Marked, Size 24(100/Pkt),Surgical Material , Surgical Spirit 99.5 % 450 Ml , Surgical Spirit 99.5 %, Pack Of 5 Lte Can , Surgical Spirit(100Ml),Bottle , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 11-15 , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 1-5 , Suture Needles Curved 1/2 Circle Round Bodyassorted Size 16-20 , Synthetic Absorbable Suture 1 With 1/2 Circle Taper Cut Needle (H) Size :1 40Mm Length 90Cm Polyglycolic Acid (Pga) (12 Foils Per Pkt) , Synthetic Absorbable Suture 2/0 With 1/2 Cir Rb Needle Size:2/0 30Mm Length 90Cm-Polyglycolic Acid (Pga)12 Foils / Pkt , Synthetic Absorbable Suture 2/0 With 1/2 Cir Rb Needle Size:2/0 40Mm Length 90Cm-Polyglycolic Acid (Pga)Pack Of 12 Foils , Syringe With Needle(10Ml Each),Needle Disposable , Syringe With Needle(1Ml Each),Needle Disposable , Syringe With Needle(20Ml Each),Needle Disposable , Syringe With Needle(2Ml Each),Syrings Disposable , Syringe With Needle(3Ml Each),Syrings Disposable , Syringe With Needle(5Ml Each),Needle Disposable , System For Delivering Saturated Atomized Steam For Decontamination Of Surfaces , T Handle & Ss Chuck Large , T Handle & Ss Chuck Small , Tbw Ss Wires No. 18, 20,22 No. , Themacol Box (25Cmx21cm) , Thermacol Box(Size 9X6x6) , Thermometer Manually For Fever Tamprature , Thread Real For Suture Cotton , Three Layer Surgical Mask(Box Of 100 Mask) Disposable , Tips For Auto Pippetes 10 To 100 Micro Litres , Tissue Roll Paper (13Cm) , Toilet Brush Super Quality , Toilet Cleaner Compound , Tonometer Schiotz , Torch Plasic Body With Three Cell Isi Market Medium , Torch Plasic Body With Two Cell Isi Market Medium , Tourniquet With Belt(Mfg By Precious Life Care Pvt Ltd)(Good Quality Pairs) , Towel Clips Medium , Towel Clips Small , Towel Mayo Forcep Size 8 To 15 , Tri Sodium Citrate , Troch Chargable Electric Led Large , Troch Chargable Electric Led Midium , Troch Chargable Electric Led Small , Tuberculin Syringe , Tubercullin Vial 1.5 Tu P.P.T 5 Ml , Tubercullin Vial 10 Tu P.P.T 5 Ml , Tubercullin Vial 2 Tu P.P.T 5 Ml , Tubercullin Vial 5 Tu P.P.T 5 Ml , Typhoid Test Card Single Test For Widdal , Umbical Cord Clamps- Plastic Material (Box Of 100 Clamps) , Uric Acid (End Point) Pack Of 10X10ml , Urinary Catheter 2 Way Size 8 Foleys , Urinary Catheter 3 Way Size 16 Foleys , Urinary Catheter 3 Way Size 18 Foleys , Urinary Catheter 3 Way Size 20 Foleys , Urinary Catheter 3 Way Size 22 Foleys , Urinary Catheter Pediatrics Size 10 Foleys , Urinary Catheter Silkolatex 2 Way Sterile, Non Toxic Size 10 Foleys , Urinary Catheter Size 16 2 Way Foleys , Urinary Catheter(3 Way Size 12),Surgical Material Foleys , Urinary Drainage Bag (Paediatric)(100 Ml / Pc, Each) , Urinary Drainage Bag 2 Litre Cap With Non Return Valve (Eo Sterile) , Urinary Drainage Bag Cap With Non Return Valve (Eo Sterile)(2 Litre, Each) , Urine Caontainer Sterile 30Ml Pack Of 100 , Urine Collection Bag Adult Standard Company , Urine Collection Bag Chlild Standard Company , Urine Collection Bag Neonatal 50 Ml Standard Company , Urine Container 5Ml Disposable (50 Per Pkt) , Urine Pan Female With Cover (Made Of Stainless Steel) , Urine Pan Male With Cover (Made Of Stainless Steel) , Vaginal Speculam Ss Cusco Large , Vaginal Speculam Ss Cusco Medium , Vaginal Speculam Ss Cusco Small , Vdrl Shaker , Ventilator Neoatal & Pediatric - Volume Cycle Ventilator, Microprocessor Based Assisted Controled Short Term For Prolonged Ventilation Can Be Provide, Volume Delivery 20 Ml To 2000 Ml Cmv, Simv, Asb, Peep, Cpap Modes Easy To Handle And Operational, Electrically Operated, Air Compresson Should Be Provided Along With The Ventilator Miounted On Same Trolley, Nebulizer & Humidifier Both Adult And Pediatric, Ups System And/ Or Battary Backup For Compressor And Ventilator, Adult, Pediatric And Neonatal Breating Cicuits (Each) Alarms Display Facillity, Fio2 Dispaly Digital Display- All Set Parameter Should Be Display Automatically , Vicryl Suture Polyglactin 30 Mm 1/2 Circle Round Body 90 Cm Size 1/0(12 Foils/ Pkt), , Vicryl Suture Polyglyconic Suture 110 Cm No.2-0 Pack Of 12 Foils , Vicryl Suture Polyglyconic Suture 190 Cm No.1-0 Pack Of 12 Foils , Viscoelastic Material - Made By Reputed Company Guaranted Eto Sterlized, Prefilled Glass Syring 3Ml , Visiter Chair Three Seater Mettalic With Handle (Ss) , Voltage Servo Stabilizer Three Phase 50 Kva , Vtm - Hi - Media With 2 Swab : (For Swine Flu) Vtm Standard Kit(3Ml Vial With 2 Regular Swabs) , Wall Fan -18 Complete & Instaltion Charge (Standardisi/Iso Reputed Company) , Wall Fan -24 Complete & Instaltion Charge (Standardisi/Iso Reputed Company) , Wall Thermometer , Warm Sleeping Bag For Neonates , Washing Solution500 Ml All Modelconc , Waste Matarial Drum Swing Model 30 Ltr. , Waste Matarial Drum Swing Model 60 Ltr. , Water Bath , Water Cooler 150X150ltr Isi Market , Water Cooler 20X40 Ltr Isi Market , Water Cooler 40X80 Ltr Isi Marked , Water Cooler 60X120ltr Isi Marked , Water Cooler With Dispenser (20 Litre) Isi Mark , Water Test Kit For Ph 400 Kit Paking , Webcamera 10 Mega Pixel , Weghing Machine 1 Kg To 10Kg , Weighing Machine (1Gm To 100Gm) , Weighing Machine 1 Kg To 100Kg , Wet Mop Complete , Wheel Chair With Hand, Foot And Neck Rest Ss, , White Phynle Compound , Wiper Medium Size , Wiper Standard Size , Wire Passser Small , Wooden Stick/Broom Stick (8Inches) , X-Rayfilm 8 Inch X 10 Inch , X-Ray Cassets With Screen Size 10X12 , X-Ray Cassets With Screen Size 12X15 , X-Ray Cassets With Screen Size 8X10 , X-Ray Cassets(6.5X8.5) , X-Ray Cassets(8X10) , X-Ray Chest Stand , X-Ray Developer Powder (13.5 Ltr) , X-Ray Developer Powder (22.5 Ltr) , X-Ray Developer Powder (9 Ltr) , X-Ray Film 10 X 12 (50 Sheets/Pack) , X-Ray Film 12 X 12 (50 Sheets/Pack) , X-Ray Film 12 X 15 (50 Sheets/Pack) , X-Ray Film 14 X 14 (50 Sheets/Pack) , X-Ray Film 14 X 17 (50 Sheets/Pack) , X-Ray Film 6.5 X 8.5(50 Sheets/Pack) , X-Ray Film 8 X 10 (50 Sheets/Pack) , X-Ray Fixer Powder (Bromex Acid Fixer With Hardner) ( 22.5 Ltr/Pkt) , X-Ray Fixer Powder It Shall Be Powder Fixer To Produce Clean Radiographs Available In Pack Size Size:- 9 Ltr , X-Ray Fixer: Powder It Shall Be Powder Fixer To Produce Clean Radiographs Available In Pack Size Size:- 13.5 Ltr , X-Ray Grid 12X15 , X-Ray Grid 8X10 , X-Ray Half File Glomer 6X15 , X-Ray Half File Glomer 6X17 , X-Ray Hanger Size 10X12 , X-Ray Hanger Size 12X15 , X-Ray Hanger Size 6.5X8.5 , X-Ray Hanger Size 8X10 , X-Ray Lead Number (A To Z & 0 To 9) , X-Ray Led Aprin Standard Size , X-Ray Led Gloves , X-Ray Steel Ka Tank 13.5 Lit. , X-Ray Steel Ka Tank 19 Lit. , X-Ray Table For Patient Examine , X-Ray View Box Double , X-Ray View Box Single , X-Ray View Box With Auto Sensor (Four Film) , X-Ray View Box With Auto Sensor (One Film) , Zigli Saw , Zipper Ploy Bag Size 4X4 , Zipper Ploy Bag Size 4X6 , Zipper Ploy Bag Size 9X6 , Zipper Poly Bag Size 5X3 , Zipper Poly Bag Size 6X5 , Zipper Polybag Size 10X8 , Zipper Polybag Size 8X6
Contract Date: Jul 21, 2025 Contract Value : 1.22 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Madhya Pradesh View Result →
15.
Agriculture #6837440 AOC
e-Tender for procurement of Laboratory Instruments/ equipment/ appliances for the College of Veterinary Sciences & Animal Husbandry under the NEC funded project entitled: “Strengthening of Laboratories at College of Veterinary Sciences & A. H., R. K. Nagar, West Tripura” for the year 2024-2025 and 2025-2026 (Rate contract for two years)- 1 Ultrasound machine with multi-frequency colour Doppler--• Display modes: B, dual B, quard B, B+M, M, CW, PW, colour and directional power Doppler• Range: 0-2 to 0-24• Display monitor: High resolution 15” LCD display with wide view angle, Probe connector:1-3• Image Adjustment: Gain: 60-120 dB, Dynamic range: 20-120 dB, Acoustic power: L/M/H, M sweep speed: 4 steps• Storage: At least 160 GB integrated hard drive, 2-3 USB ports, Still image format: JPEG, BMP, Cine loops storage format: any• General measurements: For B mode: Depth, Distance, Circumference, Area, Volume, Ratio.For M mode: Distance, Time, Heart rate. For PW/CW mode: Velocity, Acceleration, Heart rate• Special requirement: Reproductive software for Bovine, caprine and canine.Measurement andCalculation software package• Dimension: Around 410 mm (W) x 355 mm (H) x 80 mm (D)• Weight: 4 to 8 kg• Language: English• Power source: 100-240 AC• Other accessories: Convex array transducer and Linear transducer 3.5 MHz and 5.0 MHz forabdominal, MSK, Nerve, Obst. & Gynae. application; Transrectal linear transducer 7.5 MHz (For large animals).• Traveling case, Trolley• For Veterinary Use• Warranty: 3 years (on-site) 2 Hot Air Oven--Triple walled, Temperature ranges from ambient plus 5oC to 200oC, controlled by Microprocessor Based PID Controller having +/- 1oC accuracy. Inner chamber made of SS Sheet & Outer of MS Sheet. 3” thick glass wool insulation is provided between the walls and the door. Supplied with blower & 3 nos. wire mesh shelves with over temperature thermostat;Temperature sensor- PT100 or better. 220 Volts, AC. Capacity: 300-350 Litre; Warranty: 3 years (on-site) 3 BOD Incubator--• Capacity: 1000 L• Temperature Range: Ambient +5°C to +80°C• Temperature Uniformity: ±0.1 °C• Temperature Control: ±0.1°C• Chamber: Stainless steel• No. of Shelves: 4 -6• Shelves: Perforated stainless steel• Dimension: LxWxH(cm)- 80x80x180• Number of doors: 1-2• Load per rack (kg): 25-60• Light Facility: Door side/wall sides• Inside door: Transparent acrylic• Outside door: Well insulated• Display Digital display• Warranty: 3 years (on-site) 4 Laminar flow--• Cabinet made from mild steel• Pre-Filter Assemblage for Multi-Dispose particle predominantly in the size range of 5- 20 microns• HEPA Filter - 0.3 microns• Sealed white light • UV- light • Stainless Steel Work table • Front Door• Gas cock • Anti Vibration Leveling leg / Castor wheels• Extra power outlet switch • Size : 4 x 2 x 2TECHNICAL FEATURES:• AIR FLOW: Designed for 0.45m/s to 0.65 m/s• PRE-FILTERS: Size : 800 x 400x 50• Type : Flange type • Media : Synthetic, Non-oven Polyester fibre, Washable type • Casing : M.S.Powder coated• Gasket : Neoprene • Retention : 5 Micron• Efficiency : 95% • Pressure drop : 6 to 8 mmHEPA FILTER :• Size : 1200 x 610 x 75 mm - 1 no (4 feet unit)• Type : Box type, seperator type• Media : Ultra clean glass fibre paper- imported• Casing : M.S.Powder coated• Gasket : Neoprene • Retention : 0.3 Micron • Efficiency : 99.97%• Pressure drop: 25 mm of W.c.MOTOR -BLOWERS• Volts : 230 V • Hz : 50 • HP : 1/3 (4 - feet unit) • Amps : 3.5• Watts : 250 • RPM : 1440ILLUMINATION: 40 watts Fluorescent tubes NOISE LEVEL: 65 ± 5 dbVIBRATION LEVEL: less than 2.5 um (0.0001) POWER SUPPLY: 230 v AC, 50Hz, Warranty: 3 years (on-site) 5 Biosafety cabinet- Class –II, A2 (Laminar Flow)--• Product Type: Class II, Type A2 Bio Safety Cabinet• Exterior dimensions (W x H x D) should be 63 x 61.8 x 31.5 inch• Interior dimensions (W x H x D) should be 59.1 x 30.7 x 24.8 inch• Filter Specification should be H14 HEPA EN 1822, 99.995% @ MPPS• Weight should be 507 lbs• Electric requirement should be of Voltage 120 V and Frequency 60 Hz• Certification NSF/ANSI 49, UL, CE• Lighting power should be >120 fc with Two 3 inch plugged cable ports, one oneach side wall ,theReceptacles should be of 2 GFI duplex .There should be Service valves Up to 6 total (3 on each side wall)• 8 inch front opening with Sound pressure level should be <64 dB Energy consumption, operating set point 2 should be 280 W, Energy consumption,Night Set-Back mode should be 120 W, Heat output, operating mode (non-vented) should be 955 BTU/hr, Heat output, Night Set-Back mode (lights off, non-vented) should be 410 BTU/hr, Exhaust/inflow air volume 344 cfm, Exhaust volume, thimble ducted 448 cfm.• Armrests must sit above front air intake grill should be easily removable• Programmable UV light extends bulb life and saves energy ,Available UV disinfection cycle• Adjustable UV exposure time saved in memory to facilitate consistent operation• Safety interlock to prevent UV illumination when window is open• One Voltage stabilizer (10KVA) has to be supplied with the machine from reputed manufacturer.• Optional:-Virus burn-out facility.• The machine should have onsite Warranty 5 years. 6 Deep Freezer (- 20oC) (Vertical)--• Single door upright freezer, Frost Free• Capacity(L/ Cu.ft): 371• Shelf/Drawer : 7• Temp: -16°C -25°C with microprocessor based Temperature controller• Insulation : PUF• Sensor for malfunction :Yes• Sensor for Temperature Controller Malfunction :Yes• Lock : Yes• Provided with Stabilizer• Warranty :2 years (on-site) 7 Deep Freezer (- 20oC) (Horizontal)--Horizontal, 500-550 litre capacity, double door, 5- star rating, 100 % cooper wire, Temp: -20°C,Warranty: 1 year (on-site) 8 Autoclave--Capacity: 75ltrs, Vertical, Inner Dimension (Dia. x Length): 16*24 inch (400*600 mm), Watt:4KW, Operation Mode :Fully automatic (Digital Controller with Automatic Pressure Release Valve), Construction: Double Walled Inner Chamber Stainless steel 304, External chamber: Stainless steel 304 Lid Stainless steel 304,Ring & Stand: Stainless steel 304 Heater Immersion heater, Gasket: High temperature silicone rubber gasket (Joint less), Locking system Radial locking mechanism w/ pedal lifting device,Temperature range: 121°C to 126°C Temperature accuracy ±1°C• Temperature sensor: PT100• Controller :• Digital temperature controller• In-built digital timer 0-60 minutes• END of sterilization buzzer alert • Digital display of pressure• Sensor broken indication • Pressure: 15 to 20 psi• Steam release : Automatic steam release after sterilization• Release valve: Solenoid valve • Pressure display: Dial type pressure gauge• Pressure control: Automatic pressure control switch• Safety• Over pressure safety valve • Automatic vacuum breaker• Low water level cut-off sensor • Basket: Wire mesh basket• Power supply:220 Volts 50Hz • Water Inlet Valve• Directly pour into the chamber• Standard accessories:• Water level indicator (glass)• Water drain valve• Warranty: 3 years (on-site) 9 Biochemical Analyser--• Microcontroller based semi-automated analyzer to perform routine biochemistry tests (end point, fixed time & kinetic chemistries, multi standard curve calibration & memorization). For estimation of biochemical parameters for veterinary clinics.• Support tests of common domestic, pet & laboratory animals.• Min. 20 most common tests fixed, 20 more can be defined by user.• Bichromatic optic system with different wavelengths.• Should have 8 static interference filters (not filter wheel) with web length selectable from 340- 670nm.• 3 level QC with Levey-Jennings graph.• Support keyboard and mouse with USB port facility to transfer test results from analyzer to computer.• Edit Pre-programmed calculations for kinetic and endpoint assays.• Real-time reaction curve display.• Should be compatible with any commercial Kits/reagents other than OEM reagent as consumables.• Data storage for Min-5000 samples.• Instrument should be CE certified/ USFDA approved.• UPS: 1,000 VA, 360 W, with least 15 minute back- up• Should provide 3 year Warranty and should have OEM Service engineer posted at Tripura forregular prompt service(Documents to be enclosed) 10 Electrolyte Analyser--• Sample to be tested: for Na+, Cl-, K+, Ca Blood serum, plasma, Urine.• Semi-Automatic, Minimum aspiration volume not more than 100 micro litre.• Bio-sensor technology based• Large graphic display with touch screen,• Data storage min-1000 samples• Veterinary specific• Process time:≤60 sec• Should have USB port for attaching external Keyboard and mouse supplied should have RS232/LAN port for external device.• Instrument should be CE certified/ USFDA approved.• UPS: 1,000 VA, 360 W, with least 15 minute back- up• Should provide 3 year Warranty and should have OEM Service engineer posted at Tripura for regularprompt service (Documents to be enclosed) 11 Urine Analyser--• Automatic Veterinary Urine Analyzer strip based• Parameters - 10 Parameters(Glucose, Protein, pH, Specific Gravity, Leucocytes, Blood, Bilirubin, Urobilinogen, Ketone & Nitrite)• Measurement Principle - Three Wavelength Reflectance photometry Method• Attached waste bin• container• Reaction Time - 60 sec per test• Memory - 2000 Tests• Display - LCD Touch Screen, with in-build thermal printer.• Interface - Micro USB, Blue tooth etc• UPS: 1,000 VA, 360 W, with least 15 minute back- up• Should be supplied with 500 strips.• Warranty :3 year (on-site) 12 Clinical Haematology Analyser (Five part)--• Fully Automatic Veterinary Hematology Analyzer (Different species of Domestic & pet animals)- 5 Part,• Method: Electrical Impedance, Light• Scattering, Flow Cytometry, / Calorimetry.• Minimum Parameters (>19 items): WBC, LYM#, MON#, NEU#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HGB, PCV, MCV, MCH, MCHC, PLT, MPV.• Display screen, 2 histograms and 2 scatter grams• Storage: Minimum 5,000 sample results including histograms, scattergrams and patient information.• Calibration: Manual and Auto-calibration• Maintenance Friendly:1) Auto-cleaning of sample probe and tubes2) Automatic fault processing function• Sample consumption: 20uL• For Domestic, Pet &laboratory of animals: such as analysis of samples of Cow, buffalo, sheep, goat, cat, dog, pig, rabbit, rat etc.• Consumables: Supplied Along with a full set of reagents/chemical sets.• Efficiency: 60 samples per hour• Accessories: keyboard, printer, USB etc.• UPS: 1,000 VA, 360 W, with least 15 minute back- up• Should provide 3 year Warranty and should have OEM Service engineer posted at Tripura forregular prompt service (Documents to be enclosed) 13 Large Animal Sling--Animal lifting sling, capacity: 1,000 Kg, Fixed & movable with wheel, Iror/ mild steel made, winch gear box facility for lifting, cow handling belt.Size(Min.):7.5x4x4 Ft, Warranty :3 year (on-site) 14 Animal Examination table--4 ft x 2 ft x 32 incl (height) with upper top made withstainless steel solid sheet having slope with fluid drainage facility, four legs made of rust resistant iron. 15 Video Endoscopy Machine--• Should be veterinary specific & suitable for companion (Pet) animal as well as large animal.• Gastroscope should have integrated video camera with light source.• Should also have medical colonoscope.• Insertion tube should be of extremely short tip withouter diameter of 8.4 mm, working length should be 1050 mm, working channel should be 2.8 mm.• Should have 4-way deflection (upward 210 °, downward 90°, left 100° and right 100°).• Field of view should be 120 °.• Depth of view should be 3-100 mm.• Should be provided along with a Carrying Case• Caps for Working Channel, Irrigation• Tube, Cleaning Brush, Cleaning Valve.• Should have Biopsy forceps and foreign body forcep.• HD camera system should be compatible with both flexible and rigid endoscope.• Should have internal Medical grade recorder for Capturing Full HD.• Patient’s information should be editable and displayed in monitor.• Should be supplied with Medical Grade Monitor.• Should be supplied with trolley.• UPS: 1,000 VA, 360 W, with least 15 minute back- up• Should provide 3 year Warranty and should have OEM Service engineer posted at Tripura for regularprompt service (Documents to be enclosed) 16 Small Animal USG Machine--• It should have minimum 15’’ LCD monitor with 30 degree tilt function Compact and streamlined design.• It should have dual universal transducer connectors• There should have backlit keyboard• It should have 1hour uninterrupted scanning with rechargeable battery• It should have Scanning modes like:- B, B/B, 4B, B/M, M/P/W mode• The Pulse wave graph should appear in color• It should have Quick image optimization with one- click button• It should offer Instant full screen zoom with one- click• It should have offer Patient database review and analysis platform• It should have Storage capacity of minimum 1 TB• It should offer Tissue Harmonic Imaging on all probes• It should have Smart 3D enabled on all the probes. • It should offer panoramic imaging• It should have 256 grey scale • It should offer speckle reduction feature• It should have Multiple image formats: BMP, JPG, DCM, AVI, DCM, CIN• It should have Specialized measurement and analysis packages for different animals and • dedicated Veterinary transducers with anti-decay surface and longer cable• It should have Professional Package for Veterinary Use and Veterinary information management, Veterinary body mark, Veterinary comments and Veterinary OB table• It should be Supplied with two probes:• One Micro convex probe (Freq. 5-8.5 Mhz) suitable for small animal abdomen and cardiac • One Linear probe (Freq. 5-10 Mhz) suitable for small parts scanning.• The system should be warranted for minimum one year.• They should have a service centre with service engineer for support at Tripura.• The brand quoted should be time tested and have its presence and installation base of at least 20 units across the country at the veterinary institutes by the bidder only irrespective of model installed by the bidding company itself. Please attach supply orders/installation report or performance certificates in support of your bid.• The product offered should be CE marked.• UPS: 1,000 VA, 360 W, with least 15 minute back- up• Should provide 3 year Warranty and should have OEM Service engineer posted at Tripura for regular prompt service (Documents to be enclosed) 17 Spectrophotometer (Double Beam)--• Sample Cell Holder: 8 Cell Holder • Programmable 10mm• Bandwidth: 1nm • Reference Cell Holder: 10 Cell Holder• Optical System: Double Beam(1200 Lines/mm Grating)• Wavelength Range: 190-1100nm • Bandwidth: 1nm • Wavelength Accuracy: ±0.3nm• Wavelength Repeatability: ±0.2nm • Scanning Speed: Fast, Medium & Low• Photometric Accuracy: ±0.3%T • Photometric Repeatability: 0.2%T• Photometric Range: -0.3-3A,0-200%T,0-9999C • Stability: ± 0.001 A/h @ 500nm• Baseline Flatness: ±0.001A/h • Noise: ±0.001A/h • Stray Light: <0.05%T @ 220nm,360nm • Data Output Port: USB • Printer Port: Parallel Port • Display: LCD• Light Source: D2 Lamp & Tungsten Halogen Lamp (W Lamp)• Detector: Silicon Photodiode • Power Supply: AC 220V,50/60Hz• Standard Accessories- Quartz cuvette with 10mm path length 4 numbers,• Local Accessories- PC with UPS is to be offered with the system• Warranty: 3 year (On-site) 18 ELISA Reader--• The Light source should be of Quartz halogen lamp 6 V/10 W• The Wavelength range should be 340–850 nm• There should be 8-position filter wheel with 3 filters 405 nm, 450 nm, and 620 nm filters installed with additional filter of 492nm• The Filter half-bandwidth should be 3–9 nm• The Read-out range should be 0–6 absorbance units (AU)• Linearity (at 405 nm) should be ±2% (0–3 AU, 96- well plate)• The Resolution should be 0.001 AU• The Accuracy (at 405 nm) should be ± 1% (0–3 AU) or ±0.003 AU (whichever is greater)• Co-efficient of variation of Precision (at 405 nm) should be ≤0.2% (0.3–3 AU)• Measurement speed should be 7 sec (fast mode, 96- well plate) and 13 sec (normal mode, 96-well plate). • Linear shaking should be slow, medium, and fast modes• The machine should have High-contrast colour display (480 x 272 pixels)• There should be On-board display or PC control user interface• Internal memory (stand-alone) of up to 99 assay protocols and 100 test results (96-well plate) should be there• There should be USB port for PC and USB port for data export to USB memory device• The main input should be of 100–240 V (50/60 Hz)• The Power consumption should be of Max. 100 VA, 8 VA in standby mode• The Overall dimensions (H x W x D) of the product should be 8.7 x 11.4 x 15.7 inches (22 x 29 x 40 cm) • The weight of the product should be 8.5 kg (18.7 lb)• The machine should have Regulatory conformance of 2004/108/EC (Electromagnetic Compatibility Directive, EMC), 2006/95/EC (Low Voltage Directive), 2006/42/EC (Machinery Directive), FCC Part 15, Subpart B/Class B, 2011/65/EU (RoHS Directive), 2012/19/EU (Waste of Electrical and Electronic Equipment)• Suitable Software for result analysis should be supplied along with the machine for use with the PC.• The machine should have onsite warranty of 3 years.• One Additional ELISA Microplate washer has to be supplied with the machine with the following specifications• The washer should be of 96-well Plate format with One number of wash buffer bottles• One number of wash buffer bottle (2 litre) and one waste bottle (2 litre) whould be supplied with the machine• 1 x 8 wash head should be included• The range of wash volume should be 50–1,000 μLwith Prime/rinsing volume 5–100 mL and Dispensing volume 50–400 μL• The Residual volume should be <2 μL• There should be USB port for data transfer• The Dispensing accuracy should be less than <5% error for 300 μL and Dispensing precision <3% (CV) for 300 μL• Number of wash protocols to be saved should be Up to 99• The Dimensions (H x W x D) of the machine should be 13.6 x 15.2 x 9.4 inch.(34.5 x 38.5 x 24 cm)• The Weight of the machine should be 8 kg (17.6 lb.)• The machine should have onsite warranty of 3 years.• Machine should be supplied with one 2 KVA online UPS of reputed manufacturer• Additional data display and storage with following specifications:• Processor: i7-1255U (3.50 GHz up to 4.70 GHz) 12MB & 10 Cores // RAM: 16GB, 2x8GB, DDR4, 3200MHz // Storage: 1TB HDD + 512GB SSD• Software: Win11+MS Office 21 + McAfee 15 Months• Display: 27.0 FHD WVA AG Narrow Border Touch, Graphics: NVIDIA GeForce MX550 (2GB GDDR6), Keyboard and Mouse: Wireless, Warranty: 3 Years Onsite Hardware Service• Ports: 3 USB 3.1 Gen 1 ports with Power on/Wake- up support, 1 USB 3.1 Gen 2 port with Power Share, 1 USB 3.2 Gen 2 (Type-C) port, 1 universal audio jack, 1 HDMI 1.4b port, 1 HDMI-in 1.4b port, 1 RJ-45 port, 1 SD-card slot• Features: Pop-up FHD Camera with Tilt / 2x5W speakers / Bluetooth Speakers / Swivel Monitor / Type C port• Warranty: 3 year (on-site) 19 Incubator (Bacteriological)--• Temperature Range: 5°C above ambient to 60°C• Temperature Accuracy: ± 0.5°C • Temperature uniformity: Better than ± 2°C• Standard Models: Inner Stainless steel 304, 0.8 mm &Outer mild steel, 1.0 mm powder coated • Capacity: 200 Ltrs. • No. of Trays: 3 • No. of Doors: Single• Control System: Microcontroller based temperature indicator cum controller with Digital display and PT100 sensor. • PC Interface: ThroughRS-485• Memory: 500 Records• Alarm: Audio Visual Alarm if the temperature deviates from the preset temperature• Heating System: U shaped S.S. Nichrome wire air heaters• Air Circulation: Motor and blower arrangement to have uniformity of temperature under loaded condition. • Insulation: 3 Thick CFC free PUF Insulation.• Lighting: Interior illumination for working area.• Observation Door: Inside see through unbreakable acrylic door• Validation Port: 50mm validation Port with silicone rubber seal to insert sensors for validation purpose.• Trays: Specially designed solid stainless steel wire mesh trays ensure even temperature distribution• Other: Castor wheels, mcb, adjustable tray height arrangements, heavy duty latch with lock & key • Power: Works on 230V AC single phase 50Hz.• Safety feature: Additional safety thermostat to cutoff the air heater in case of over shoot of temperature • Certifications: ISO9001:2008, ISO 13485:2012• Documentation: LABTOP will provide IQ, OQ, PQ documents with Material Test Certificates and Calibration reports• Warranty: 3 years 20 Monopan Digital Balance--• Display: LED touch screen• Special built-in- applications:net total, totalizing,statistics, weighing, massunitconversation, animal weighing.• Protection: chemical resistant finish• Password protection: single level password protection• Anti-theft lock: Kensington lock and lockdowncapability for cable or chain.• ID creation: sample ID and batch ID creation possible.• Interface:-USB type C interface - Industry Proof RS232 9-pin interface- Backward Compatibility (by Using RS232 port)- Data transfer: direct data transfer to Microsoft windows programs.• Weighing pan: best repeatability with rectangular weighing pan.• Language: English.• Technical specification:- Weighing capacity: 220g- Readability: 0.1mg- Repeatability: 0.08mg- Linearity:0.06mg- Typical stabilization time:<1.5sec- Typical measurement time : <2 sec- Weighing chamber height :240mm- Weighing pan size:90mm- Warranty: 02 years (on-site) 21 Physiograph--Standalone unit having coloured TFT display for displaying online and offline recording data. Systems have sic couplers fitted in as single unit easy to carry. System shall have Eight transducers (Force, Pressure, Volume, Respiration, Temperature, Pulse, Respiration Belt and Isotonic).Facility to store recording data and review the same on TFT. Interface to the computer – Through USB. System provided with software to review and printing the recorder data from PC. Accessories like ECG electrodes, EEG electrode, Bio Potential Junction Box, EMG disc electrodes, Ground electrode, EEG Paste, ECG gel, etc. should beprovided. Warranty :3 year (on-site) 22 Micro haematocrit Centrifuge--Speed range of 200-14,000 rpm, max. RCF 18,620 xg. Independent control of speed and time. Easy operation with intuitive menu and easy-to-read display. Included hematocrit rotor: 24 capillary capacity, max. speed of 12,000rpm. Optional tube rotor: 24 place 1.5/2mL capacity.Warranty :3 year (on-site) 23 pH Meter--• pH Range: -2.00 to 14.00 pH• Resolution/ Accuracy: 0.01 pH/± 0.01 pH• ORP Range : ± 2000 mV • Resolution/ Accuracy:(± 199.9 mV) / 1 mV (beyond) ± 0.2(± 199.9 mV) /± 2 mV (beyond)• Temp. Range: 0 to 100 °C (32.0 to 212.0 °F)• Resolution/Accuracy: 0.1°C(0.1 0 F)/±0.3 °C/±0.5°F (0 to 70 °C)• ATC: Yes (0 to 100 0 C)• Buffer Options USA : pH 1.68, 4.01, 7.00, 10.01, 12.45 ,NIST: pH 1.68, 4.01, 6.86, 9.18 , 12.45 • No. of pH Calibration Points: 5 points• Built-in Electrode Arm: Yes • Memory : 100 Data sets• Electrode: Included, single junction pH electrode • Temp. Probe: Included• Power Requirements: Included, 100 /240VAC,SMPS Power Adapter with US/UK/EUR/Japan plug ,9V,6W, CENTRE +ve• Warranty: 3year (on-site) 24 Flame Photometer--Range : Na: 0 – 100 ppm,K : 0 – 100 ppm, Ca: 15 – 100 ppm, Li: 10 – 100ppm (Optional). Sensitivity : Na: 5 ppm, K : 5 ppm, Ca: 10 ppm Li: 10 ppmAccuracy : + 2% upto 40 ppm,+ 5% above 40 ppmWarm up time: 10 minutes. Power: 230 V + 10% AC, 50 HzWarranty: 02 years 25 Binocular Microscope--• STAND: Single Mould, die cast sturdy stand with anti rust material with textured paint, with ergonomic extended base for hand rest and greaterstability, anti-fungal mould treated.• VIEWING BODY: 30° inclined Siedentopf Binocular tubes, 360° rotatable with IPD 50- 75mm. Anti-fungal mould treated.• EYEPIECE: Wide field paired eyepiece, high quality, and achromatic 10x/20 mm with dioptric adjustment. Antireflection coated & Anti-fungal mould treated.• NOSEPIECE: Backward angle, Quadruple revolving Nosepiece (ball bearing type), with soft rubber grip.• OBJECTIVES: Infinity Plan Achromatic objectives, antireflection & anti-fungal mould treated, 4x/NA 0.10, 10x/NA 0.25, 40x/NA 0.65SL, 100x/NA 1.25 (SL, Oil)• STAGE: Double layered graduated mechanical scratch proof rectangular stage size 142 x 133mm, X/Y cross travel range 76 x 54mm. Co-axialcontrols, spring clip, Low drive right hand movement controls, double specimen holder, anticorrosive coated.• COARSE & FINE FOCUSING: Focusing Co-axial coarse and fine focus on ball drive system and brass metal gears for smooth operation with torqueadjustment on one ring side.• Warranty :3 year (on-site) 26 Trinocular Microscope with Photography Unit--Microscope:Type: Upright bright field compound Trinocularmicroscope with Koehler Illumination Control Display: 5-element display on either sideof the stand and long-life blue LEDs which is well readable from several meters distance.Illumination: 3W LED warm-light, 3200K, lifetime-25000 hours, Homogeneous fieldillumination 20mm, can perform plug-on swivelling mirrorOptical system: Color-corrected infinity opticsEyepiece: A pair of e 10x suitable for spectaclewearers and retro fittable eyepiece with pointer;Eyepiece with field of view of 20mm; Eyepiecessecured with setscrews against unauthorized removal.Objectives: Plan-Achromat: 4x, 10x, 40x, 100x,with 4-position nosepiece tilted back and objectivessecured against unauthorized removalCondenser: Focusable and centreable Abbe condenser 0.9/1.25Viewing Tube: Trinocular Tubes (50%:50%) with25° angle and field of view 20 mm; Viewing with30° angle and field of view 20mm for Heightadjustable siedentopf tube; Siedentopf up anddown position for 2 different viewing heights.Stage: Mechanical reckless stage with Long-livedstage surface; With well-readable vernier and robustcontrols; Stage size- 140x140, travel range 75x40;Extremely stable stand to broad base and low center of gravity.Power: With power unit integrated into stand byway of a parking position with cable storage in thestand rear wall. Ergonomic shape for convenient,safe carrying; With IEC adapter for conversion into abench-top power pack; With external unit that is easyto change in case of defect ; With Power of 100- 240V and 50-60Hz.Carrying Handle: With carrying handle that iscompletely integrated into stand; With ergonomicshape for convenient and safe carrying Dust cover: With dust CoverAnti-fungus treated optics: Must provide anti-fungus certification from manufacturer.• Should provide schematic diagram of microscope• System should be ISO and European CE Certified (provide document)• After Sales & Service Support should be available in Agartala (provide contact no. and address).Warranty: 5 years warranty for microscopeDigital Imaging System:• A 8.3 MP Digital Microscopy Camera with• facility for standalone operation as well as in PC.• Facility available for Live Image on screen• Display Direct image• Recording and Capturing along with Image• Analysis Software• Camera package shall contains the following accessories:o USB 3.0 hub Type-C,o USB 3.0 flash drive, Type-C and Type-Ao USB 3.0 cable Type-C to Type-Ao Power <(>&<)> signal cable camera to microscopeo stand with suitable Power adapter- Export into ZVI, BMP, GIF, JPG, PNG, TIFF,HDP image formats.- Sensor: Sony CMOS image sensor Color, Rolling Shutter Number of Pixel: 3840 (H) x 2160 (V) = 8.3MP, Ultra HD (4K)Selectable Resolution: 3840 x 2160 and Full HD (1080p) = 1920 x 1080,Pixel size: 1.85 μm x 1.85 μm, Effective Area: 7.1 mm x 4.0 mm, IR filter.- Entire System i. e. Microscope, Camera and Software shall be from same manufacturer.- Warranty: 2 years (on-site)Additional Data Storage Unit:• Operating System: Windows 11 Home• Processor: 12th Generation Intel Core i5 (up to4.4 GHz)• Memory:8 GB DDR4-3200 MHz RAM• Storage: 512 GB SSD storage• Graphics: Intel® UHD Graphics 730• Moinitor: size- 60.5 cm, FHD (1080p) with IPS display• Pointing Device: Wired Mouse• Keyboard: Wired• Should include Genuine Microsoft Office Home & Student 2021 Lifetime Subscription• Warranty: 3 years (on-site)• 03 years Quick Heal antivirus protection subscription• UPS: 1,000 VA, 360 W, with least 15 minuteback-up 27 Micropipette set--• Kit should includes 0.2-2, 2-20, 20-200 & 100-1000 ul Single Channel Pipettes, 1 Pipette Stand (6 Position), 4 Sizes Tip Boxes with Tips, Reagent Reservoir Sample, Calibration Certificate• Also included extra two pipettes 1-10ul, 10- 100ul.• Fully Autoclavable• Advanced volume gearing mechanism• Should have large, easy-to-read display• Double-action pipetting button with a rotating upper part, for easy and light volume setting.• Should be light weight, least RSI (Repetitive Strain Injury)• Ergonomic design, separate soft touch tip ejector• In lab calibration and easy maintenance, easy to open• Super blow out piston for small volumes to ensure delivery of micro size drops• Should be ISO and USFDA Certified (provide document)• 2 years warranty 28 Desktop Computer--• Operating System: Windows 11 Pro (original)• Processor: Intel® Core™ i7-12700 (up to 4.9 GHz with 25 MB cache and 12 cores)• Memory: 8 GB DDR4-3200 MHz RAM• Storage: 1TB HDD + 512GB SSD• Graphics: Intel® UHD Graphics 770• Chipset: Intel® Q670• Connectivity and Communications: intel® Wi-Fi 6E and Bluetooth® 5.3 wireless card• Ports: 1 headphone/microphone combo; 1 USB Type-C 10Gbps signaling rate; 3 USB Type-A• 10Gbps signaling rate• Video Connectors: 1- HDMI 1.4; 1- Display Port 1.4; 1- VGA• Monitor: size- 60.5 cm, FHD (1080p) with IPS display• Pointing Device: Wired Mouse• Keyboard: Wired• Should include original preinstalled latest version Microsoft Office Home, & Student 2021Lifetime Subscription and 5 years Quick Heal antivirus subscription• UPS: 1,000 VA, 360 W, with least 15 minute back-up• Warranty: 03 years (on-site) 29 Distillation unit--• Capacity Distilled Water Output: 1.5 LPH• Minimum cooling water requirement (Ltr/min): 1• Heater: Quartz• Boiler: Boro 3.3• Condenser: Boro 3.3• Biological Activity: Pyrogen Free• Conductivity S/cm*:<3 × 10-6• Power consumption (kw): 3 kW• Voltage (V) : 230V• Dimensions (L × B × H) in mm: 640 × 630 × 520• Warranty: 2 years 30 Rotary Microtome--• Designed for effortless manual sectioning via a counter-balanced and smooth-running hand wheel. • Instrument with X/Y specimen orientation• Fast exchange system for specimen clamps, both Universal & Standard types• Personalized user selectable coarse feed wheel turn direction, either clockwise or anti-clockwise to suit user’s preference • Retraction on/off function• Two mechanical trim steps: 10 μm and 50 μm• Blade holder for disposable blades –must be suited for both high & low profile blades and standard specimen clamp.• The object head with +/-8° X/Y orientation equipped with a fast specimen clamp exchange system for improved workflow.• Space on top of the instrument housing for storage of sectioning tools and accessories.• Maintenance-free vertical cross-roller guides and horizontal specimen feed via precision cylinder guide system.• Distortion-resistant base plate to ensure optimum overall stability.• The vertical stroke of 59 mm• Horizontal specimen travel range of 25 mm• Allow to section specimens up to a size of 50 mm x40 mm x 40 mm.• Ergonomically designed hand wheel grip.• Hand wheel lockable in any position via brake lever attached to base plate• Operating conditions o Operating temperature range 10°C to 35°Co Temperature range during storage 5°C to 55°Co Relative humidity max. 80%, non– condensing o Storage humidity < 80%• Technical information • Section thickness setting range 0.5–60 μm• Section thickness selection from 0.5–2 μm in 0.5 μm-steps• from 2–10 μm in 1 μm-steps • from 10–20 μm in 2 μm-steps• from 20–60 μm in 5 μm-steps• Total horizontal specimen feed 25 mm• Vertical specimen stroke 59 mm• Specimen retraction ON/OFF• Specimen orientation• Horizontal 8° & Vertical 8°• Rotation ± 90°• Dimensions and weight (Preferred)• Width 438 mm 17.24”• Depth 472 mm 18.58”• Height 265 mm 10.43”• Working height (knife edge) 105 mm 4.134”; Weight (without accessories) 27-30 kg.• Should have more than 40-50 installations only in East India, with 50% being in reputed Govt. Institutions (provide documentary evidence).• Must be CE & USFDA certified/approved (provide documentary evidence). OEM: Sakura/ Leica/ CellPath/ Tanner Scientific• Should have dedicated OEM’s own Company Service Support for Eastern/North-Eastern Indiawith company’s own factory trained service engineers based in East/ North-Eastern India to provide prompt support (provide documentary evidence).• Warranty: 5 years (on-site) 31 Paraffin Floatation Water Bath--Four Racks - Double Walled, inner made of SS sheet & outer of MS sheet. Heating is done by strip type heaters & 2 thick fibre glass wool insulation is provided. Temperature range shall be from Water Temp. / Ambient to 100oC, +/-0.5oC, controlled by a Digital Indicator Cum Controller with Lid & Trays. Operated on 220V A.C. Mains. Provided with Powder Coating Paint Finished. Warranty: 3 years (on-site) 32 Scalding Tank (Stainless Steel)-- Tank capacity-30-40 litres, Voltage: 220-240 V.Control panel with digital temperature indicators. Material: Stainless steel, Type: Electrically operated. 33 Electric Stunner--Stunner with tongs made of SS with isolated handles to operate on sheep/goat and pigs. Shock proof control box with analog display for volt and ampere. Variable stunning voltage. Electrical supply from the control box to SS tongs through electrical cable.• Voltage: 230 V +/- 10%• Frequency: 30-50 Hz• Stunning Voltage: 80-400 VAC• Stunning Current: 1.5 Ampere 34 Captive Bolt Pistol--• Non-penetrative concussion stunner• Universal in application from large bulls to small lambs, with varying power load strengths• Well balanced, comfortable ergonomically designed handle• Automatic bolt return• Standard tool in 0.22 or 0.25 calibre.• Robust solid construction. • Features/Specifications: • Chrome steel finish• Knurled handle for better grip • Fewer parts than competitive brands• Bolt penetrates 2.25 35 Portable Colour Analyser--Digital colour meter that measures colour in LAB colour values and finds Delta E colour difference between master and samples using NR seriescolorimeter. Warranty: 02 year (on-site) 36 Muffle Furnace--Temperature range up to 1000oC, workingtemperature up to 950oC, size 19 x 16 x 18 (L X W X H) inches, 220/230 volt, Warranty: 02 year (on-site) 37 Micro Kjeldahl Apparatus--Horizontal, MS powder coated with 6 heaters with energy regulator control, maximum temperature approximately 4000C, capacity for heating of 500 mlKjeldahl flask, Warranty: 02 year (on-site) 38 Mixer Grinder--No of Jars: 3; Jar Size: Wet Jar (1.5 Litres), Multipurpose Jar (1 Litre), Chutney Jar (0.3 Litres); Jar Material: Stainless Steel; Body Material: ABS; Blade Material: Stainless Steel; Speed Control: 3 Speed Control + Pulse, Wattage: 1000W; Voltage:230 V, Warranty: 01 year (on-site) 39 Lab Willy mill--Body Material. MS, Power Source. Electric, Voltage- 240 V, Frequency- 50 Hz, Power Consumption- 0.75 kW, Load. 43 Kg. 40 ECG machine--• 3 Channel ECG Machine with Automatic interpretation.• Simultaneous 12 Leads acquisition and 3 ch recording.• 4.3” inch colour TFT LCD display ECG Wave.• Support touch panel and key pad input ways.• Built in USV / RS 232 interface (ECGNET Software)• Built in rechargeable Li-ion Battery support less than three (3) hours continuously work.• Warranty :3 year (on-site) 41 Digital Camera--Dimension: Width – 125mm, Length – 64, Height – 96mm, Thickness – 76.5mmMegapixel: 24.2MP, Focal Length: 18 – 55mm 42 Cow Replica Model--Approximately one sixth the size of the real cow, this cow models shows the internal and external anatomy of a female cow, including ruminant system, reproductive system and digestive system.Model includes:1. Model on display stand2. Cross sectional view of internal and external anatomy3. 13 removable parts4. Quick start guide5. Online access to curriculum, students activity and presentation slides6. (2) ( 20” X 30”) posters :Beef cuts and cow anatomy7. 1 year limited warranty8. Dimension : 10”X21”X33./5”9. Weight : 45 lbs10. 13 detachable parts Curriculum :1. Cow anatomy2. Digestive tract3. Reproductive tract• Presentation slides , students assessment tools 43 Large Dog Model--The Large Dog Model is a detailed model of a large- breed female dog. Featuring internal and external anatomy, it splits in half to reveal removable organs. Additionally, incorporate the included curriculum for a complete experience.Package includes:• Model on display stand• Cross sectional view on internal and external anatomy• 10 removable parts• Quick start guide• Online access to curriculum• 1-year limited warranty Product Dimensions: 15” x 27” x 30” Product Weight: 47 lbs.10 detachable parts Curriculum :Lessons topic :1. Canine Anatomy2. Digestive Tract3. Reproductive SystemIncludes Presentation slides, Students activity and assessment tool 44 Cow Anatomy 3D Flip Chart--The Cow Anatomy 3D Flip Chart is a portable relief chart that splits down the middle to reveal 3 separate bovine anatomical illustrations: the outer view of the cow, the skeleton and internal organs and reproductive tract. It is one-sixth the size of an actual cow and features white board material. Use it to teach bovine anatomy and other bovine systems. It includes hindquarter, hoof and reproductive tract callout diagrams.Cow Anatomy 3D Flip Chart includes:• 3 contoured flip charts: exterior anatomy, internal skeleton and organs and internal organs• Tabletop stand• Floor stand on wheels• Online access to curriculum• 1-year limited warranty• Made of white board material for use with most dry erase markers• Weight: 35 lbs.• Dimension: 18” X 40” X 32” Curriculum Spotlight1. Bovine AnatomyPresentation slides and students assessment tool 45 Demonstration Model of Cow--• Natural size, detachable skin to show superficial and deep muscle.• Head and neck detachable and dissectible.• Viscerae are dissectible to demonstrate various systems within the organ are also detachable.• Detachable hoof 46 Exhibition Panel/ Panel Board with stand--• Application: Exhibition Panel• Size: 4x 36 inch, Height: 6-8 foot• Material: PVC• Shape Rectangular 47 RMS Speakers--SRX-120DX, 100Watts, STA-150, With tripod standof height adjustment : 3.5ft-6.5 ft, Load Capacity; 40 Kg, Warranty: 2 years 48 Wireless Microphone--Audio Output:0110mV/600,Freq. Resp: 50-14000Hz, Antenna: Detachable through BNC Connector, power: AC-220-240 for AC adopter, ModulationMade : FM(F3E), Warranty: 2 years 49 Amplifier--AC & 24V DC Operated, 250 Watts,6Mic & 2Aux, Warranty: 2 years 50 Public Address with Speaker--Amplifier: WA-320/AWM-321, Warranty: 2 years 51 Interactive board--Size - 86’’ with 4k Ultra High Definition (3840 x 2160) @ 60 Hz with OLED display technology with 8 ms response time, 20 points IR multi touch interface, 3 HDMI, 4 USB, Bare dimension of 1990 x 114 x 1201 mm with < 320 W power consumption, build in android8.0 with < 3 GB RAM and < 32 GB ROM with OPS 52 Video Camera (HD)--• Product Dimensions: 33 x 22 x 28 cm; 1 kg• Flash memory type: SDHC• Resolution: 4k• Compatible Devices: Laptop• Special Features: Face Detection• Mounting Hardware: Camera Recorder, Li-ion Battery Pack (7.28V), Adaptor (12V), AC Cable,Eye Cup, Handle Unit, Mic Holder, O/I• Number of items: 7• Display Technology: OLED• Standing screen display size: 3.5 Centimetres• Image stabilization technology: Digital• Image Stabilisation: Yes• Optical zoom: 24 x• Digital zoom : 24 x• Min Focal Length: 23• Video Capture Resolution: 4K• Batteries Included: No• Batteries Required: Yes• Wireless Type: 2.4 GHz Radio Frequency• Connector Type: Wi-Fi• Form Factor: Compact• Lens type: Zoom• Warranty: 2 years (on-site) 53 Antibiotic zone reader--Digital display range : 0 mm to 35 mm, readability0.1 mm, warranty: 2 years 54 Hot Plate Analgesiometer--30x30 cm heating surface with perpex enclosure micro controller based digital temperature indicator Temperature range : 30-80 cWarranty: 2 years (on-site) 55 Plethysmometer--Digital display with pedal switch control, Warranty: 2 years (on-site) 56 Magnetic stirrer with bar--With pivot ring , dimension 6x10 mm, 9.5x40 mm, 12.7x 76, 8x65 mmWarranty: 2 years (on-site) 57 Small Animal Anesthetic Apparatus--• Respiration mode Manual mode, open mode, closed mode, semi-open and semi-closed mode.• APL valve should adjustable easily, range: 0-60 cm H2O and there should be one safety pin top ofis there is high pressure should be released easily.• It is easy to clean the dirty and the color is black.• It is a 0-4L/m high precision flow meter which is very available for small animal usage.• It has a select bar technology, which is easy to change the anaesthesia vaporizer with one switch.• The Vaporizer should be made by stainless steel with key filler.• The CO2 circle absorber has inspiration valve and expiration valve, which have plastic cover to observe the animal breath clearly for doctors.• The CO2 circle absorber has a high-quality soda lime chamber, which is poly-carbonate (PC) material for medical usage. It is very strong andnot broken and should have 500 gms capacity.• It has an option for platform on the top, where the patient monitor is put.• The structure is very reasonable for doctor to use this machine alone: the flow meter is on the left,the vaporizer is on the middle, the CO2 circleabsorber is on the right, the airway pressure gauge should be top of absorber, which can monitor the airway pressure of close system. And the O2 flush is on the left top of flow meter for easy operate.• This machine is very small to save the space of the operation room.• This machine can be put on the trolley, also can be put on the table at the same time can be put on our wall mount arm.• Warranty: 2 years (on-site) 58 Multi parameter vital signs monitor--• Monitor should have integrated non-invasive, invasive measurements & features suitable for small, medium and large animals. (Cat& Dog )• Should have TFT/LCD display with at least 12.1 inches with numeric display simultaneously. Should be capable of customized display.• Should be compact & portable with carrying handle.• Should have facility to monitor ECG, HR, SpO2, Resp., NIBP, Respiration & Temp. & optional: - 2IBP & Etco2 .• Should have Equipped with the accessory box, the medical staff will be more convenient to store and take out the accessories.• Should display at least 8 waveforms of selected parameters.• Should be able to store & display at least 120 hrs. of graphical and tabular trends of all parameters and minimum 2000 groups of NIBPmeasurement.• The SpO2 technology should also sense in low perfusion. PI (Perfusion Index) should be displayed on the screen.• Monitor should have ST segment calculation with facility to detect life-threatening arrhythmia.• Should have internal rechargeable battery for 2 hours monitoring or more.• Should have audio/visible alarm.• Should have ESU & Defibrillation protection.• Should have drug calculation, hemodynamic calculation, ventilation calculation, oxygenation calculation & renal function calculation asstandard features.• Other bed observation should be there as standard feature.• Warranty: 2 years (on-site) 59 Hydraulic OT Table--• Two panel table top systemthat adjusts form horizontal to near vertical to hold the pets thedesign position during surgery.• Overall size of the top: 20”W x55”L.• Powerful and durable electric lifting actuator holds 120Kgs on the surgery top.• Improved waster channel and drain hole design allow for fluidly drain flow. Close fitting translucent bucket improves waste collection.• Buffered hinges and air spring added to cushion the dropping impact of the whole top and V-top side panels.• The IV pole mount is selded on.• Table can be lifted form 28” to 47”.• Workshop Swivel Angel 0°-45°.• Buffer hinge.• Heating system with accurate temperature monitoring and control.• Category: Operation Table & amp; Light• Warranty: 2 years (on-site) 60 Shadow less Lamp--• The LED Bulbs that are fixed into this is meant for saving power consumption• The Sterile handle Present in this equipment helps in easy adjustment.• The operating light designed for the use in high demanding surgeries.• LED bulbs used to ensure low energy consumption and long service life.• Light head is resistant to disinfectant, easy to clean.• LCD Display for showing all important parameter like intensity/on/off.• Flexible and stable balance arms suspension system for height and angle.• Light Intensity: 2,40,000 Lux• Number of LED’s: 72• Life span of LEDs: 50,000 hrs• Focus Dia: 15-25 cm• Power supply: 160V-240V DC, 50Hz Control Unit: SMPS• Dome size: 500mm• Spot Diameter: 125-150mm• Colour Temp. 3500-4800k• Power Supply: 220v/50HzAC• Power consumption: 40Watt• LED Average Light: 50000 Hrs• Intensity Control-30-100• Warranty: 2 years (on-site) 61 Electrocautery machine-- • Should Have Microprocessor Controlled Surgical Generator• The unit should comply with safety requirement of IEC60601-1 & IEC 60601-2-2 and test report for each power setting need to be present.• The equipment should have brand name / model name mentioned on the equipment. Original Literature of the Manufacturer needs to be given• Machine should be able to monitor changes in tissue impedance• Number of coagulation modes should be 4• Maximum power in coagulation mode should be 150w• Number of bipolar modes should be 3 • Maximum power of bipolar mode should be 120w • Should have patient plate monitoring facility• Should have 1 hand switch & 1 foot switch for monopolar mode & 1 foot switch for bipolar mode• The system should have facility to use two monopolar coag modes simultaneously• Should have touch screen keyboard / membrane pad for power settings• Should have lcd / led display • Should have 3 segments for the display• Should have individual display for bipolar and monopolar cut and monopolar coagulation • Rf leakage current should be 100ma • The power supply should be 230v (±15%) 50hz• Type cf equipment (iec 601 –1 & iec 601-2- 2) defibrillator proof. Various modes in electrosurgical unit: a) mono-polar cut: 1. Pure cut: 300- 400 w 2. Low cut: 300-400w, 3. Blend: 200 -250 w, b) mono-polar coagulation: 1. Spray: 120 w 2. Fulgurate:150 w 3. Desiccate: 120 w c) bipolar coagulation: 1. Cut/precise: 70-120 w, 2. Force/standard: 70-100, 3. Micro/Macro: 70-100 W• Auto Start coagulation & auto stop coagulation Input Power source: Operating• Range: 170-260 VAC Line Frequency: 50-60 Hz Minimum High Frequency Leakage• Bipolar Less than 60mA Monopolar less than 150mA Standard Accessories to be provided: 1. Reusable/Disposable dual pad Silicon/Polyhesive Plate with cable 2. Bipolar forceps with cable 3. Mono polar-hand switch pencil 4. Dual pedal foot switch for Mono-Polar 5. Single pedal foot switch for bipolar 6. Power cord• Unit should have patient plate Contact Quality Monitoring System/REM System- With this atthe moment the contact between Plate & Patient reduces, it stops the HF delivery & gives error message with audio visual indications• The system should have Return ElectrodeContact Quality Monitoring (REM) System preferably with Adaptive REM facility• The system should have facility to use two monopolar coag modes simultaneously• The system should have ability to restore last power setting• Machine should be able to upgrade to a higher version• The unit should operate at local climatic conditions & up to temperature of 40 degree Celsius.• Warranty: 2 years (on-site) 62 Electric dehorner--• Material: Stainless Steel• Automation Grade: Automatic• Product Type: Electric and stainless steel• Capacity: 50 HZ• Warranty: 2 years (on-site) 63 Community nest box--• Product Dimensions: 45.6L x 13W x 26H• Material: Alloy Steel 64 Feed grinder (Mini)--• Capacity: 300 kg per hour• Motor Power: 2 hp• Dimensions (LxWxH): 110X125X185mm• Weight: 50kg• Material: Mild Steel• Hammer Size: 14 inches• Number of blades: 20• Automation Grade: Automatic• Frequency: 50Hz• Voltage: 440V• Warranty: 2 years (on-site) 65 Feed mixer (Mini)--• Capacity: 100 kg• Motor Power: 3 hp• Material: Mild Steel• Mixing Chamber Volume: 100 liters• Motor rpm-1440• Foot mtg• Gear shaft arrangement rpm -35• Very high quality and strong construction in MS• Warranty: 2 years (on-site) 66 Milking Machine--• No of Buckets: 1.0• Productivity: 1-10 cows/hour• Capacity: 25 Litre• Automation Grade: Semi-Automatic• Power Input (W): 110W• Voltage (V): 110-220V• Frequency (Hz): 50/60 Hz• Warranty: 2 years (on-site) 67 Incubator (Hatchery)--• Egg Capacity: 500 egg• Temperature Range: 37.5 Degree C• Inner Material: Hylum• Bird Type: Chicken• Dimensions(LXBXH): 52 x 42 x 36 inch • Automation Grade: Automatic• Humidity Range: 99%• Voltage: 220 V• Weight: 78 kg• Hatching Rate: 85%• Usage/Application: Poultry Farm• Frequency: 50-60 Hz• Phase: Singe Phase• LED Display: Yes• Power Consumption: 200 Watt• Warranty: 2 years (on-site)
Contract Date: Feb 15, 2025 Contract Value : 1.22 Crore
Government Departments No of Bidders 12
16.
Housing Urban and Rular Development #4654663 AOC
Tender For Tourism Development Work Of Neem Kroli Baba Birth Place At Village Nagau In District Mainpuri. (U.P.), 1 DORMITORY+DIGITAL LIBRARY+PLATFORMEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 2 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil1.5 Mtr To 3.0 Mtr 3 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil3.0 Mtr To 4.5 Mtr 4 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil4.5 Mtr To 6.0 Mtr 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 9 Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete 10 Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 11 Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform 12 Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 13 Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts 14 Centering and shuttering including strutting, propping etc. and removal of form forEdges of slabs and breaks in floors and walls Under 20 cm wide 15 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)G.F. 16 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)F.F. 17 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 18 Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 19 Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)G.F. 20 Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand)F.F. 21 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class - 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)G.F. 22 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class - 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)F.F. 23 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 24 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measuredas per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:-(1)treatment for masonary & foundation 5 litres per sq.m.(2)back fill in immediate contract with foundation 7.5 litre per sq.m(3)treatment of top surface of plinth filling 5 liters per sq.m.(4)treatment of soil along external parameter of building 7.50 lire per sqm. (For payment plinth area to be measured as per IS Code). 25 Providing and fixing SS sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm. 26 Providing and fixing SS tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. 27 Providing and fixing SS handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 30 Teak wooden door 31 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part |!) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 32 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming toIS: 2202 (Part I) 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 35 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 36 Providing & Fixing of Aluminium window with 5 mm glass pans.W1 37 Providing & Fixing of Aluminium window with 5 mm glass pans.W2 38 Providing & Fixing of Aluminium window with 5 mm glass pans.W3 39 Providing & Fixing of Aluminium window with 5 mm glass pans.W4 40 Providing & Fixing of Aluminium window with 5 mm glass pans.V2 41 Providing & Fixing of Aluminium window with 5 mm glass pans.S1 42 Providing & Fixing of Aluminium window with 5 mm glass pans.S2 43 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 44 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 45 Providing and fixing ball bearing for rolling shutters. 46 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 47 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of slab (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 48 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 49 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 50 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 51 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 52 Add for plaster groove in plastered surface or moulding to R.C.C. projections. 53 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 54 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 55 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water abDSRption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. With out base concrete Glazed Vitrified tiles Matt/Antiskid finish of 600X600mm size. 56 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 57 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 58 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 59 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shadeArea of slab over 0.50 sqm 60 Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge 61 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 62 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 63 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 64 Finishing walls with Putty approved brand and manufacture and of required shade on undecorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work. 65 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 66 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 67 Supply and filling in sunken with brick bats under floors, including watering, ramming, consolidating and dressing complete. 68 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 69 Providing and fixing false ceiling at all heights including providing andfixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms/sqm (both sideinclusive) as per IS : 277 and consisting of angle cleats of size 25 mmwide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm diax 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the anglehangers of 25x10x0.50 mm of required length with nuts & bolts of requiredsize and other end of angle hanger fixed with intermediate G.]. channels45x15x0.9 mm running at the spacing of 1200 mm centre to centre, towhich the ceiling section 0.5 mm thick bottom wedge of 80 mm withtapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centreto centre, shall be fixed in a direction perpendicular to G.|. intermediatechannel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick27 mm high having flanges of 20 mm and 30 mm long, the perimeter ofceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre ,with 25 mm long dry wall screws @ 230 mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with the help ofdry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing andfinishing to a flush finish of tapered and square edges of the board withrecommended jointing compound , jointing tapes , finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and twocoats of primer suitable for board, all as per manufacturer’s specificationand also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed,all complete as per drawings, specification and direction of the Engineerin Charge but excluding the cost of painting with12.5 mm thick tapered edge gypsum moisture resistant board 70 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 71 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 72 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. For 100 mm dia pipe 73 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 74 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 75 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe(Plain) 76 Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal size diameter 77 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 78 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 150 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 79 Construction of Apron drain ofwidth 150mm and depth as per required of site but minimum 150 mm with neat finish & required slope as per apporoved by E/I. 80 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m? 81 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m² 82 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes 83 Providing and fixing of Ornamental wooden decorated columns in various elements for all levels. solid Teak wood load bearing columns with solid t wood crowns supported on hand-carved Wooden bases.Wood shall be free from cracks, lines stains and even in shade for each element . The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size) moulding. The carving and molding work shall be of very good qualityapproved make as required and as approved by the Architects and Engineer in charge 84 Supply & fixing Nuvocotto Euro Dark Chocolate clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Architect In charge. 85 Supply & fixing Ornamental clay tiles of 10X16 inches for ceiling including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane also includes the cost of all the necessary fitting and required for completion of the work as per Architect In charge. 86 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge. 87 Providing and fixing of Ornamnetal woodenTeak wood door shall be free from cracks, lines stains and even in shade for each element . The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size) moulding. The carving and molding work shall be of very good qualityapproved make as required and as approved by the Architects In charge. 88 The providing and fixing of ornamental mashrabiya with a customized design and size crafted from high-quality Teak wood. The customization will be based on the designs and sizes outlined in the attached drawings. The Teak wood used must meet impeccable standards, ensuring it is free from cracks, lines, stains, and exhibits uniform shading for each element. The execution of the work will involve various processes, such as manual or machine carving, ornamental detailing, traditional craftsmanship, figure work of any type and size, as well as molding. All carving, molding, and CNC work must adhere to stringent quality standards, utilizing approved materials and methods specified and approved by the Architects in charge. 89 Providing and installation of a crafted koomb or kalasam of customised size and shape not less than 300mm heightmade of terracotta blocks, with finishes achieved through cutting, carving, engraving, etc., also includes the cost of all necessary fittings required for the completion of the work as per the Architect In charge. 90 Providing and Fixing of Wooden Louvered of Teak wood finish in a frame of 30x30mm thk. also includes the cost of all necessary fittings required for the completion of the work as per the Architect In charge. 91 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10metre height, backing filled with a grout of average 12 mm thick cementmortar 1:3 (1 cement : 3 coarse sand) including pointing in white cementmortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sidesby means of cramps and pins which shall be paid for separately) : 70 mm thick - Red sand stone - Exposed face machine cut and table rubbed with rough backing. 92 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 93 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 94 Washed stone grit plaster on exterior walls in two layers with customised stone, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Architect-in-charge. 95 Hand Chiseling and edging on supplied stone to gain the desired finish as approved by Architect in charge; and supply and Layingwater soluble penetrative solution for waterproofing of masonry building material &with Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. 96 Supply & fixing Teak Wood Roofing Elevation Border Design Sheet of approved thickness (not less than 12-20mm) and width minimum: 200 mm;also includes the cost of all the necessary fitting and required for completion of the work as per Architect in charge. 97 Supply & fixing Crafted from premium solid teak wood Bracket of customized size and design; also includes the cost of all the necessary fitting and required for completion of the work as per Architect in charge. 98 Below Raft / Footings / Grade Slab with mechanicaly thermofused fully bonded HDPE membrane: Supplying and installing 1.5 mm composite thick fully bonded weldable HDPE membrane conforming to IS 16471:2017 requirements of UG waterproofing structures, requirements to provide Type A fully bonded protection of UG waterproofing structures. The membrane should be minimum 2.4 m wide comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective layer with lap Joint Strength at overlaps >15000 N/m ASTM D 6392:2012. The membrane shall have minimum of 75mm side and end laps which shall be thermofused with leister of all the joints for assuring water-tightness and achieving monolithic membrane. End laps and side laps should be a minimum of 100 mm with the weld size of minimum 60 mm in case of a double weld system, comprising of two parallel welds of 20 mm wide each with a 20 mm air channel gap in between the two weld lines. The size of the membrane should not be less than 2.4 Mtr. x 20 Mtr. to minimise the joints. This membrane shall be continued over the vertical surface in case of confined areas, footings , toe portion and raft sides upto 200mm height above the Raft bottom , but terminated minimum 100mm below the top edge of the raft slab/footings and fixed as per recommendation. The waterprofing membrane shall have following minimum properties and waterproofing application shall be done by manufacturer authorised application team who is having minimum 10000 Sqm of Raft waterproofing works done with HDPE membrane in a single project.1) Lap Joint Strength at overlaps >15000 N/m ASTM D 6392:20122) Resist hydrostatic pressure of over 70 m head of water as per ASTM D5385 Modified3) Puncture Resistance of 800 N(± 5 to 10 %) as per ASTM E1544) Adhesion to concrete of > 880 N/m as per ASTM D 9035) Tensile strength of HDPE Without Adhesive (Film) of > 25 Mpa as per ASTM D412 modified6) Elongation of > 400% as per ASTM D 412 modified7) Low temperature Flexibility -25deg C - Pass 99 Retaining wall water proofingProviding & laying 1.5mm THK SBS modified self-adhesive, cross laminated HDPE valeron lining waterproofing membrane, Samshield, conforming to IS 16471:2017 Type A, requirements of UG waterproofing structures, over the solvent based bituminous Torchshield primer @ 4 sqm/litre. The lap with HDPE membrane shall be 100mm treated with double sided tape. The SBS membrane shall have Roll Size: 1 Mtr X 10 Mtr, Thickness DIN EN 1849-1, values 2.1, Puncture resistance > 200N as per ASTM E 154, Crack bridging (10 cycles) > 1.5mm as per ASTM C 836, Softening Point (oC) = 105 as per IS 1205/1978, Low temperature Flexibility – 10 deg C as per ASTM D 5147, Chemical Resistance (pH) as per ASTM D 543, Tensile Strength (Longitudinal) >3.5 Mpa, Hydrostatic pressure > 50M as per DIN 1048Providing and fixing HDPE protection having dimple height of 6 to 8 mm, as a protection board, over the waterproofing membrane for vertical surface stuck to the membrane by spot bonding method, usingsynthetic adhesive with butt joints etc. complete.***Note : Necessary back filling to be done by the main civil contractor within 2-3 days time progressively after installation of the membrane and protection board , taking care not to cause damage to the waterproofing treatment ..Termination of Membrane at 300mm above G.L. The waterproofing membrane shall be terminated on the vertical surface. The membrane shall be terminated either by creating a U shaped groove of approx. 10 mm x 10 mm size within the RCC retaining wall, tucking the membrane within the groove, followed by sealing the groove with polyurethane sealant/ epoxy mortar or alternatively the membrane shall be terminated by fixing a metal termination bar on the vertical surface, with butyl sealant between the metal plate and wall surface and sealed on top with P.U. sealant etc. complete. 100 Construction Joint TreatmentWater Swellable Bar:All Starter & Construction Joints of raft slab, retaining walls and water retaining structures : Providing and applying water swellable bar at starter & all construction joints, of c/s size of minimum 20mm X 5mm, Hydroswell HDP / Be-sealed Polybar, it shall have resistance to detoriation from salt water, volumetric expansion > 200%, Elongation > 400%, Shore A Hardness > 35, Tensile strength > 2 Mpa, Temperature resistance : (-) 20 to +75 deg C, Water head resistance > 50 m. It shall be fixed to the concrete using a gun grade hydrophilic fevicol adhesive / or mechanically fixed by binding wire with steel reinforcement, as recommended by manufacturer. Later post construction, groove cutting of the construction joints 25mm X 25mm size internally / externally, cleaning with compressed air and thereafter filling with Hydroblok 300 Polymer modified cementitious mortar, all as per manufacturers recommendations, etc, complete. 101 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge 102 FAÇADE RENOVATIONDismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 103 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 104 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 105 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) 106 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 107 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 108 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand) 109 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 110 Cost of ornamental cement concrete chattri of size 900X900X1500mm, including the cost of supplying, casting and installation of the chattri with dome , also including the cost of all the ornamental works in plaster, finishing with texture paint as per design and directions from Architect in charge 111 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. 112 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 113 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 114 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 115 Supplying, fabricating, transporting, hoisting and fixing in position good quality of 70 mm White/Red sandstone in various elements for all levels.The stone shall be Hand-chiseld and rough surface , reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), Text Engraving,ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 116 PLUMBINGProviding and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 117 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 118 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 119 Providing and fixing Black Conical Bell Vessel wash basin for top/under counter mounting with fabricated MS brackets painted white synthetic enamel paintover a coat of primer of approved brand, 15 mm C.P. brass pillar tap of auto closing typewith pop-up waste, 32 mm C.P. brass bottle trap and pipe all of approved brand and manufacturer to wall with C.P. wall flange and rubber adopter for waste connection complete, including cutting and making good the walls & Floorswherever required.White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tapsConical Bell vessel with tall pillar type Faucet 120 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern 121 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 10 litre white P.V.C. automatic flushing cistern 122 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth. Granite stone of approved shade 123 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board510x1040 mm bowl depth 250 mm 124 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 125 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe32 mm dia 126 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe40 mm dia 127 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 128 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm 130 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 131 Providing and fixing toilet paper holder :C.P. brass 132 Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 398975 mm O.D. 133 Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989110 mm O.D. 134 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75 mm 135 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 136 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :75 mm O.D. 137 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :110 mm O.D. 138 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. 75 mm 139 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. 110 mm 140 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accesDSRies for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)75 mm Shoe 141 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accesDSRies for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)110 mm Shoe 142 Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS - 398975 mm size 143 Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS - 3989110 mm size 144 Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 398975 mm size 145 Providing and fixing heel rest sanitary bend Sand cast iron S&S as per IS - 3989110 mm size 146 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 398975 mm size 147 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 3989100 mm size 148 Providing and fixing terminal guard : Sand cast iron S&S as per IS - 398975 mm 149 Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989100 mm 150 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 151 Providing and fixingof fully automatic NO TOUCH durable & shock proof hand drier of approved make & manufacture suitable to operate on 220 volts, single phase 50 hz, A.C. power supply, 1500 Wattand directly plugged to power point complete in ABS plastic body having drying time 20-30 seconds complete as per direction of Architect in Charge.(Make : Kohler/Jaguar or Equivalent) 152 Providing, checking, storing and fixing Automatic Perfume Sprayer of approved quality, fixed to wall /door with concealed CP screws etc complete in all respect as directed by Architect-in-charge.(Make : Kohler/Jaguar or Equivalent) 153 Providing and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector complete with all respect as per direction of Architect in Charge. (Make : Kohler/Jaguar or Equivalent) 154 Providing and Fixing 2 No. hand rail size 600X100mmand grab bar 450mm longto mounted on the track (vertically and laterally) for handicaped toilet complete in all respects as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 155 Providing and Installation of Soap dispenser & Holder complete in all respects as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 156 Providing and fixing round mirror - matte black complete in all respects as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 157 Providing and Fixing vanity in walnut finish complete in all respects as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 158 Providing and Fixing Stall Partition complete in all respects as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 159 Providing and Fixing Step Can Trash Bin as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 160 Providing and Fixing Robe Hook as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 161 Providing and Fixing Toilet Brush Holder in Brushed nickel as directed by Architect-in-charge. (Make : Kohler/Jaguar or Equivalent) 162 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 163 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 164 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 15 mm nominal outer dia pipes 165 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 20 mm nominal outer dia pipes 166 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 25 mm nominal outer dia pipes 167 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall 32 mm nominal outer dia pipes 168 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal outer dia Pipes 169 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal outer dia Pipes 170 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall32 mm nominal outer dia Pipes 171 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes 172 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 173 Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. External work40 mm dia, nominal bore 174 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends)25mm dia, nominal bore 175 32 mm dia, nominal bore 176 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore 177 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore 178 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diameter 179 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)15 mm nominal outer dia pipes 180 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)20 mm nominal outer dia pipes 181 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)25 mm nominal outer dia pipes 182 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work (internal work -exposed on walls)32 mm nominal outer dia pipes 183 Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality40 mm dia, nominal bore 184 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work 40 mm dia, nominal bore 185 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore 186 Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)15mm nominal bore 187 Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)20mm nominal bore 188 Providing and fixingG.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)25mm nominal bore 189 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore 190 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:893115mm nominal bore 191 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore 192 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.15 mm nominal bore 193 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m :Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 194 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm O.D. 195 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 196 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 197 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 198 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame. 199 Extra for every additional depth of 0.10 metre or part there of main hole. Size 900 x 800 mm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 200 Extra for every additional depth of 0.10 metre or part there of main hole. Size 1200 x 900mmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 201 ELECTRICALWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 202 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 203 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire 209 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire 210 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 212 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 213 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 214 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet 215 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 216 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 217 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 218 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 219 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) 220 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 221 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 222 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 223 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair 224 Installation ,Testing and commissioning of ceiling fan, including wiring thedown rods of standard length (up to 30 cm) with 1.5 sq. mm FRLSH PVC insulated , copper conductor , single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required 225 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 226 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 227 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 228 Supplying and fixing following way, single pole and neutral (SPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door 229 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 230 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door 231 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door 232 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 233 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 234 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 235 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB 236 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. 237 Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. 238 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. 239 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 240 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A 241 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A 242 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 243 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 244 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 245 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 246 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 247 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 248 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness 249 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness 250 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 251 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 252 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. 253 Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. (Use as a Decorative Mirror Light) 254 Supply and fixing of 36 to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect 255 Aesthetically designed LED linear fixture suitable for suspended down type with housing made of high quality extruded aluminium alloy including die-cast aluminium end cap. These series are also available with seamless continuous lighting system ensuring no visible dark spot or light leakages(Philips/Havells/Panasonic) as per design approved by architect incharge 256 Providing and installation Aesthetically designed LED Pendant light15 W 4000K downlight with white /black powder coated polycarbonate housing and equiped with aluminium die-cast housing,(Philips/Havells/Panasonic) as per design approved by architect incharge 257 LED Track Light Leander-10W(Black,4000K) LED Track Lights(DL01-10083) 258 Uranus-1 Meter Black LED Track (TR01-10002) 259 Black LED Track straight connector (TR01-10006) 260 Track Suspension Kit(TR01-10013) 261 Supply and fixing of Mirror Light 262 Supply and fixing of Wall Light 263 Supply and fixing of Step Light 264 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 6 sq mm x 2 core 265 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 10 sq mm x 4 core 266 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 267 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 35 sq mm x 3-1/2core 268 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 95 sq mm x 3-1/2core 269 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 6 sq mm x 2 core 270 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 10 sq mm x 4 core 271 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 25 sq mm x 3-1/2core 272 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 35 sq mm x 3-1/2core 273 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 95 sq mm x 3-1/2core 274 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 6 sq mm 275 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 10 sq mm 276 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 16 sq mm 277 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 25 sq mm 278 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 35 sq mm 279 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 50 sq mm 280 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 95 sq mm 281 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. Cubicle TypeIncoming -200 Amp MCCB-1 No.Outgoing - 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs)100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs)63 Amp 4P MCCB - 1 Nos. (for Terrace pump))40 Amp DP MCB - 2 Nos. (Spare) 282 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 283 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 284 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 285 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 286 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 287 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 288 MECHANICAL VENTILATIONSITC of Sigma 6 Inline Fan , air flow 415 cmh, Ideal for Hot/Cold air Transfer, Energy Saving Long Life Ball Bearing Motor, Easy to Install, Strong Air Flow, Low noise level, High Static Pressure, Fully copper winding motor 289 SITCOf Sigma 8 Inline Fan , air flow 820 cmh - 910 cmh, Ideal for Hot/Cold air Transfer, Energy Saving Long Life Ball Bearing Motor, Easy to Install, Strong Air Flow, Low noise level, High Static Pressure, Fully copper winding motor 290 SITC of Zeta AW 8 , air flow 180 cmh , Diy high velocity exhaust fan with fitted back draft damper, Turbo cylinder fan blade design for powerful air-stream extraction, Square design exhaust fan with removable easy clean cover, Ultr Quiet Motor, Easy installation clamps to fit and secure fan into ceiling, 100 mm diameter side ducting for easy duct installation, Easy clean removable fascia, self ceiling exhaust damper to prevent drafts, complete with white 291 SUPPLY & INSTALLATION OF VENTILATION PIPE MAKE-PVC Pipe 160 mm 292 SUPPLY & INSTALLATION OF VENTILATION PIPE MAKE-PVC Pipe 110 mm 293 SUPPLY & INSTALLATION OF Alumunium PIPE MAKE-Aluminium pipe 110mm - 3 rmt 294 SUPPLY & INSTALLATION OF PVC ELBOW MAKE-ASTRALPVC Elbow 160 mm 295 SUPPLY & INSTALLATION OF PVC ELBOW MAKE-ASTRALPVC Elbow 110 mm 296 SUPPLY & INSTALLATION OF PVC ELBOW MAKE-ASTRALPVC Socket 160 mm 297 PVC Socket 110 mm 298 SUPPLY & INSTALLATION OF PVC REDUCER SOCKET MAKE-PVC Reducer Socket 200mm X 160mm 299 SUPPLY & INSTALLATION OF PVC REDUCER SOCKET MAKE-PVC Reducer Socket 110mm X 160mm 300 SUPPLY & INSTALLATION OF PVC TEE MAKE-ASTRALPVC Tee 110mm LW 301 SUPPLY & INSTALLATION OF PVC TEE MAKE-ASTRALPVC Tee 160mm LW 302 SUPPLY & INSTALLATION OF GRILL & DIFFUSERDiffuser RMD 6 303 SUPPLY & INSTALLATION OF GRILL & DIFFUSERDiffuser RMD 4 304 SUPPLY & INSTALLATION OF GRILL & DIFFUSERGrill FGS 6 305 SUPPLY & INSTALLATION OF GRILL & DIFFUSERGrill FGS 4 306 FIRE SYSTEMSupplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. 307 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 308 Supplying, installation, testing & commissioning of manual call box of MS Construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 309 Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. 310 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in MS box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 311 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone 312 Fire Alarm Panel with Talk Back Syetm Arrangements :Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.10 Zone panel for fire alarm system.250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby)Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos. talk back unit -1 Set.Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 Set.Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 Set.Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH Each sealed maintenance free batteries -1 Set. 313 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 314 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 315 Fire Pump Set :Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Terrace PumpHorizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m Head 316 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 317 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 318 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 319 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm dia 320 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia 321 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia 322 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia 323 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 324 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 325 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m 326 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 327 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 328 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 329 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 330 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 331 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 25 sq mm x 3-1/2core 332 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 25 sq mm 333 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 334 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 335 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 336 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 337 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 338 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 339 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 340 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 341 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 342 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 343 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).1500x900 mm (Indoor Cabinet) Only Frame 344 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -2 Sets 345 THEMED INTERIOR & ART WORKSWall Panelling: Fabricating & fixing full height plywood panelling (overall thickness 62mm) consisting of 50mm x 25mm x 2mm GI sections approved Make framework with all necessary reinforcements required of GI, at spacing not exceeding 600mm x 1200 . Partition framework to be fixed to existing masonry walls. Rate to include providing and fixing of additional GI sections of approved size as per Architects drawings. Cost to include additional sections (horizontal & Vertical) as required for fixing of Digital Displays, Screens.,, Glass boards, and White boards as indicated by the Architect. Cost to also include the necessary provisions required to take Data & Electrical conduiting.Boarding: Boarding with 12mm th Fire resistant pre laminated LDF Board LDF boardCost to include an average projection of 600mm from true wall including creating slopes, curves in elevations as indicated in the drawings.Cost to include providing of recess of upto 200 mm such as coves and niches, the shape shall be not measured seperatelyCost to include providing necessary BWP plywood backing up to 18mm for Digital displays as indicated in the drawingCost will be measured based on the board up area and not for frame works.Approved Brands - 1. Frame : Jindal, apollo, sections or equivalent2. Plywood - Green ply, Kitply, Merino, archidply or equivalent3. Laminate– Merino, Greenlam or equivalent 346 Fixed Furnitures: Providing and supply of custom built fixture with GIformwork made of 50 x 50mm section frameto base e. Frame spacing shall not exceed @ 600mm c/c one way and the framework cladded with first skin of 16mm thk ply. Or 19 mm block board for display cabinets The top skin shall be finished with laminate of approved shade and color, and/or matching lots, as per Architects instructions,(if so required), on partitions, ceiling and paneling as perpattern and design as indicated on the drawings. Cost to be inclusive of All joint to be supported with frame or support members as specified by the Architect. Joints to be bonded with only joint Adhesive provided by the approved dupont vendor- as specified .Cost to be inclusive of any coving to be done for the panelling along the wall & ceiling and any stencil cuttingas per architects detail drawing.Provision to be provided for lighting, electrical, data & AV wiring including conuting, equipment mounting etc., The contractor shall co-ordinate with other agencies to ensure seamless workflow including co-ordination with their services, finishes requrired etc., in correspondance with the project managerWhere ever applicable glass box will be constructed with 8mm th clear toughened glass fixed using UV glue / silicon carefully joined with in exemplinarry skill to perfect corners. The glass box will be placed on the podium with support from solid acrylic.Cost of light fixture excludedPlywood Make:Century, Greenply, Merino or other brand approved by the architectSolid Acrylic : Make: Hanex, Samsung Staron Glass Make : Saint Gobain Clear GlassProviding and Fabrication of Powder coated stucture with base like spec stand Polycarbonate / Corian printed graphic Translation Works - English text will be provided by the client. Hindi and Punjabi translation to be done. 347 Providing and Fabrication of Powder coated stucture with base like spec stand Polycarbonate / Corian printed graphic Translation Works - English text will be provided by the client. Hindi and Punjabi translation to be done. 348 Size : W2400 X D700 X H1000; Reception Table, Particle Board & MDF Top, Reception 2 (make Geeken/ Godrej/featherlite) customised as per Architect incharge 349 LOOSE FURNITUREMainpuris City Gallery - Chairs/Custom designed benchesModel : Custom, featherlite, monarch Ergo, Ergo Designs 350 Culture & arts crafts - Chairs/Custom designed benchesModel : Custom, featherlite, monarch Ergo, Ergo Designs 351 Workstation in AV Room Size (6 x 2 x 2.5 ft) : Workstations made of Powder coated M.S structuer and Pre laminated LDF Board of 20mm th for table top and 16mm for sides complete with raceway / conduits for internal wiring etc., complete along with a storage unit of 450 x 450 x 450 mm with 2 drawers and 1 shutter. Make : Godrej Interio / Featherlie / Ergo / Custom/Equivalent 352 Closed storage units made of pre-laminated LDF boards with 2 shutters per stroage unit with box hinges of Ebco make and skirting rasied by 75 mm; Back Storage Unit, 18mm PLPB, Extruded Aluminium Profile; Evoke 4, W2250 X D450 X H2200 make Godrej / Featherlite / Monarch Ergo / Equivalent/Geenken or equivalent 353 Vinyl print with Installation - Providing & Fixing Printed Vinyl Graphics on Punned or Levelled Surface of (3M or Equivalent) ,overPlywood /MDF or Laminate. Cost to include cleaningfor any stains, scffolding for height upto 8000mm from FFLApproved Make - 3M, LG, Avery/Equivalent 354 Artefacts/Manuscripts DiplaySize : 24 0 x 12 0 355 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 356 Design , supply and Installation of Glass chandelier Installation of size 72x30x36 Oval Shaped . 357 Providing and Fixing Knauf Channelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 21mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound abMRbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. (Average value of AbMRption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. SUSPENSION: The panel shall be downwardly installed with tongue and groove mechanism using Inside clip on Knauf Prelude 43 with 24 mm wide T - section flanges having rotary stitching on all T - sections i.e., the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 43mm, 35mm and 30mm respectively. The deflection loading of the system shall be 17.8 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with deflection loading of 21.4kg/m. The end details of the main beam and cross tee shall be made of pre hardened steel and the cross tee is designed to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T - Sections shall be made of hot dipped galvanized steel of 100 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. Installation should be carried out as per Knauf recommended procedure. The grid shall be installed with suspension system of Knauf make.INSTALLATION: To comprise main runner spaced at 1200mm centre to centre securely fixed to the structural soffit using Knauf suspension system (specifications below) at 1200mm maximum centre. The First/Last Knauf suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Knauf wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centre to centre.The panel shall be downwardly installed with tongue and groove mechanism using inside clip on grid. Panel shall be butt jointed in the shorter side using industrial/wood glue and expansion joint of 15mm to be kept at every 7.2m. Expansion joint can be finished using a transition profile. KNAUF SUSPENSION SYSTEM accesMRies manufactured and supplied by Knauf consisting of M6 Anchor Fasteners with hanger hole, pre–Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. Additionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners. 358 Providing and fixing of 12 mm th clear toughened glass panel fixed over Showcase it with all required hardware with holes and profile support as per the drawing. 359 Content & Application Development:i) Research--Complete and comprehensive research on the life, philosophy, beleifs and work of Sant Ravi Das Ji basedontheadvisorynote, included in the tender. The work will include butnot belimitedtoappointmentofexpert researchteam,travel,stay,food,meetings and consultation with subject experts, archival material identification, all consumables, printing, stationary, copies of films, drafts and preparation of a Content Document for submission to and approval by the Department and Architect in-charge approx.20 seconds per Exhibitii) Script & Translations--Developing and writingofanarrativescriptthatwouldbe writtenfromtheresearchedandapproved contentprovidedbytheclient.Scriptwould lend itself to narrative syncing the video, playedseparately.Scriptingrequiredintwo languages: Hindi and English. With Hindi being the source language. The translation could be outsourced to another person though it will be the responsibility of the selected scriptwriter. There would be some poetic and lyrical contentinthescript.Thescriptwritermust havepreviousexperienceinhavingwritten scriptsofcontemporary,historicalcontent. Qualityofscripttobesuperior,succinctly capturing the mood, vision and sense of mission of the protagonist, while also painting an appropriate picture of reality of the times. As approved by the Department and Architect in-chargeScriptmustdojusticetotheintentofthe museum.approx.20 seconds per Exhibitiii)ArchivalAcquisition--ofallnecessary Archival Material, photographs, films, letters, workingdrafts,diaries,manuscriptsand objects (specific toSant Ravi Das Ji & his beleifs, teachings and of related events in India & his native village) from various government and private sources, inclusive of rights to use for museum exhibit, includingediting,restoration,touchupand also partial use, if required. As approved by the Department and Architect in-charge approx.20 seconds per Exhibit 360 Placement of museum display objects at their appropriate location with required precision including necessary acrylic hooks, frames, nuts bolts, T & P etc. required for proper completion of the job as per the requirement of Museum norms and directions of Engineer in charge/ concerned authority. 361 Providing and fixing Canvan fabric used in most canvases are either linen or cotton. Of the two, linen is considered the best due to the quality of the surface and its durability, of printed graphics over canvas and mounted over a framework made solid Wood (items complete with all required hardware) 362 Providing and fixing frames of customized size Imperial Frames Stratford Artist Vintage Picture Frame for 3/4 Thick Canvas, Museum Quality Wooden Antique Photo Frame 363 C.C.ROADEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 364 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 365 Construction of dry lean cement concrete sub base over a prepared subgrade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications,cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. 366 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 367 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.Cement concrete prepared with batch mixing machine 368 Providing and fixing in position pre-moulded joint filler in expansion joints. 369 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound. 370 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more 371 GRASS PAVEREarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 372 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 373 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 374 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. 375 MURAL WALLEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 376 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 377 Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 378 Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 379 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 380 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 381 Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete 382 Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers 383 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 384 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 385 COBBLE PATHWAYEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 386 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 387 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 388 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class - 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 389 15 mm cement plaster in 1:4 (1 cement : 4 coarse sand) finished rough with sponge. 390 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge. 391 LANDSCAPETrenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 392 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 393 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 394 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 395 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 396 Rough dressing the trenched ground including breaking the clods. 397 Fine dressing the ground 398 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 399 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 400 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in chargeWith grass Turf 401 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 402 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 403 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 404 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 405 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 406 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 407 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 408 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 409 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 410 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 411 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 412 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 413 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 414 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 415 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 416 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 417 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 418 Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 419 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 420 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 421 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.. 422 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 423 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 424 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Poly bags & as per direction of the officer-in-charge. 425 Providing and stacking of Asparagus sprengeri of height 15 cm to 20 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 426 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 427 Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy leaves lush green leaves well developed in big size HDPE Bags as per direction of the officer-in-charge 428 Providing & fixing White/Colored River (Stone) Pebbles size of 1 to 2 dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. 429 SEPTIC TANKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. 430 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.1.50 M TO 3.0 M 431 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.3.00 M TO 4.50 M 432 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 433 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, including the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 434 Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform 435 Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 436 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 437 Cement plaster (1:3) finished with a floating coat of neat cement.20 mm Cement Plaster 438 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 439 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 440 Providing & fixing 75mm dia vent pipes. 441 Providing & fixing of 75mm dia cast iron terminal guard. 442 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500mm internal diameter 443 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 444 EXTERNAL WATER SUPPLYProviding & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)40mm nominal bore. 445 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40mm nominal bore. 446 Constructing brick masonry chamber 600 x 600x750mm insidewithF.P.S. brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slabwith 1 : 2 : 4 mix (1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size); necessary excavation,foundationconcrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plasteringwithcement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 447 STORMDRAINEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 448 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 449 Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 450 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 451 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster 452 Fire Pump Set :Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : Jockey PumpHorizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 70 m Head 453 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65 mm dia 454 L.T. Switch Panel Board :Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only.Lighting Panel :Incoming -100 Amp MCCB - 1 No.Outgoing - 63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No. (for Spare) 455 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 456 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable size 25 sq mm x 3-1/2core 457 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 25 sq mm 458 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 459 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 460 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 461 EXTERNAL ELECTRIFICATIONStreet Pole with LED Lamp :Supply of 4 Meter height Carley Square 40W LED in Extruded aluminium bottom pipe (grade 6063 with test certificate) Sq. 150 x 3mm thickness, extruded aluminium stem with inner ribbed Sq.30 x 2mm thickness, extruded aluminium top pipe with inner ribbed with Light Distribution 360°. Pre treated with silicone gaskets. PDC aluminium service door 330mm height x 75mm width at 335mm height above the base plate shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable, 6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. For better lighting performance there is Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Lamp fixed is position. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >87%, power factor >0.95, IP65, THD <10%, Surge protection 5KV. LED Colour Temperature 3000K, 230-240Vac, CRI >80, MacAdam step> 3, Mechanical resistance IK08. MS mounting plate Sq. 250 x 12mm thick steel of grade E250 to IS 2062:2011 with 4 elongated holes 38 x 19 to suit M16 bolts at CC180. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation pole. Hot dip galvanised foundation bolt. The pole should undergone Pure polyester powder coated process, Mild shot blasting. The product should be BIS and CE Certified. Make as per Klite KL-4663/Unilamp/Ligman. 462 supply and fixing following capacity of automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors, HRC fuse, isolating switch, metering instrument and instrument box with CTs etc.complete in all respect.40 A SPN 463 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following sizesize 6 sq mm x 2 core 464 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following sizesize 10 sq mm x 4 core 465 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed, underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable size 6 sq mm x 2 core 466 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed, underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable size 10 sq mm x 4 core 467 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cablesize 6 sq mm 468 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable size 10 sq mm 469 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 470 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 471 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 472 Supply of Spike light luminaire LED 3000K/4000K/5700K 240Vac CRI >80 Mac-Adam step 3, Input power 6W having Dimension 101 x Ø90 x 330 mm, Beam Angle : 40° with Electronic driver ON/OFF. CE and BIS Certified. LUMINAIRE TYPE Spike Mounted luminaire. IP rating IP66. MATERIAL CHARACTERISTICS Die-Cast aluminium housing & Front ring (grade ADC12 with testcertificate). Surface mounting spike made of Polypropylene black. Silicone clear gasket. SS fasteners. Mechanical resistance IK06. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE Toughened Clear glass diffuser of 4mm thickness. This luminaire contains built-in LED modules. LED modules are engineered accordingly tothe existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40?C. Operating ambient temperature range is from -15?C to +50?C. Driver efficiency >84%, power factor >0.95, THD <10%, Surge protection 2.5KV. There may be changes in fixture selection and quantity as per architect intent. Make: K-Lite KL- 4265/Unilamp/Ligman 473 Supply of RADO MINI Wall light 474 Supply of Zedo Round Surface Mounting Light 475 Supply of SILL FAÇADE LIGHTING 476 Supply, Installation, Test in gand Commissioning of LEDRGB/RGBW flood lighting luminaire for facade lighting with Die- cast aluminium housing, powder- coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The be amangle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 VAC, 50Hz with power factor>0.9. Fixture shall be suitable to operate at anambient temperature range of-10°Cto +50° C and shall be IP65 and IK06 rated. Life time shall be atleast L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS(IS10322) and shall be complete with all necessary accessories required for proper working of fixture in cluding weatherproof connection cables, waterproof connector setc. as required. 30 W 477 Supply of 3000K/4000K/5700K In-ground 8W asymmetrical luminaire made up of die-casting with Ø116 stainless steel 316 grade front ring with silicone black gasket and toughened clear glass diffuser. With Electronic Driver, The luminous flux of the luminaire is upto 550 lm for 3000K BA- 35°/45° (Asy). The ingress protection is IP67 and impact resistance of IK08. The luminaire is integrated with high power NICHIA LED with CRI=80, SDCM=3, L70/ B10 @ 60000 Hrs at L70B10. The integral constant current driver comes with the power factor greater than or equal to 0.9, total harmonic distortion less than 15% with operating efficiency greater than 80% and a surge protection of 3KV. The driver input voltage 240Vac at 50-60Hz, operating voltage of 100- 277Vac and operating temperature of -20° ~ +40°C with CE confirmed BIS approved. There may be changes in fixture selection and quantity as per architect intent Make: K-Lite KL-4098, Unilamp/ Ligman 478 Supply of 3000K/4000K, 230Vac, 3W Symmetrical Monocolour Stix Light made of Luminaire made of extrusion aluminium tube with Pure polyester powder coated finish for high durability having height 1162mm, Ø25mm and Non yellowing UV stabilized Clear Acrylic Rod with 200mm length for Illumination. Mounting spike arrangement should be available to facilitate easy soil installation at any desired location. Luminaire should be IP65. The Luminaire provided with one metre cable length and IP67 connector. Lighting Performance CRI >80 MacAdam step>3, Electronic driver ON/OFF (External driver), Lifespan of the luminaire >60,000 hours at 40°C. Operating ambient temperature range is from -25°C to +55°C. Driver efficiency >85%, Surge protection 2KV. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires. Make as per Klite KL-4554/Unilamp/Ligman, 479 Supply of Surface mounted spot light LED 3000K/4000K/5700K 240Vac CRI >80 MacAdam step 3 Input power : 10W Dimension Ø95 x 124 mm, Beam Angle : 40° without Electronic driver ON/OFF, LUMINAIRE TYPE : Wall Mounted luminaire. IP rating IP66. MATERIAL CHARACTERISTICS: Die-Cast aluminium housing & Front ring (grade ADC12 with test certificate). Surface mounting Bracket made of Polypropylene black. Silicone clear gasket. SS fasteners. Mechanical resistance IK06. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. LIGHTING PERFORMANCE: Toughened Clear glass diffuser of 4mm thickness. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40?C. Operating ambient temperature range is from -15?C to +50?C. Driver efficiency >84%, power factor >0.95, THD <15%, Surge protection 2.5KV. Make: K-Lite Model no.-KL-4245/Unilamp/Ligman 480 Supply of linear 3000K/4000K/5700K In-Ground Grazer 24Vdc CRI >90 MacAdam step 3 Input power : 12WLight Distribution should be Symmetrical Electronic driver ON/OFF (External driver) CE and BIS Approved. LUMINAIRE TYPE: Facade encapsulated3000K/4000K/5700K In-Ground Graze with IP67. MATERIAL CHARACTERISTICS should beHigh grade aluminium housing (grade 6063 with test certificate) with End cap, SS fasteners & Clip, Mechanical resistance IK07. LIGHTING PERFORMANCE:: Polyurethane Encapsulation clear diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum(TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV. Including required accessories There may be changes in fixture selection and quantity as per architect intent Make Klite KL-3277,Unilamp/Ligman 481 Supply and fixing of Footlight Inground Luminare (One way/Two Way/Four Way) 482 Supply and fixing of Power Grazer - 32, Mono Light , 6W 483 Supply and fixing of LED Bollard robustly designed IP65/IK10 Bollard is easy to install with base plate(BCP150 LED /NWPSU 220-240V 7043)(K-litePhilips/Panasonic/Havells or Equivalent) 484 FILTRATION TANKExcavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 m and lead upto 30 m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge upto distance of 30m from the foundation trenches. (where machine can not reach/move). 485 Excavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 m and lead upto 30 m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge upto distance of 30m from the foundation trenches. (where machine can not reach/move).Additional Lift 1.5 to 3.0 m 486 Excavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 m and lead upto 30 m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge upto distance of 30m from the foundation trenches. (where machine can not reach/move).Additional Lift 3.0 to 4.5 m 487 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 488 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 489 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform 490 Class-150 brick work in 1:6 cementand COARSE sandmortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. 491 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 492 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.All types of soil400 mm dia 493 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia 494 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 495 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 496 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 497 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 498 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 499 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 500 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 501 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 502 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design.With 20x20 mm square bar 503 GULLY CHAMBERExcavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soilPipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. 504 Providing, laying and fixing PVC pipe confirming to IS make working pressure 6 kg/cm2including testing labour T&P and all complete. 160 mm diameter 505 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C pipes including bed concrete as per standard design : 150 mm diameter R.C.C pipe 506 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 507 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 508 SILTING CHAMBERExcavation in foundation in ordinary soil (loam, clay or sand) including lift upto 1.50 m and lead upto 30 m and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge upto distance of 30m from the foundation trenches. (where machine can not reach/move). 509 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 510 Class-150 brick work in 1:6 cementand COARSE sandmortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. 511 15 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 (1 cement : 3 coarse sand) 512 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 513 Centering and shuttering including strutting, propping etc. and removal of form for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 514 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 515 TUBEWELL WITH BOARINGBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.300 mm dia 516 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of requireddia, conforming to IS: 12818, including required hire and labour charges, fittings & accesDSRies etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 517 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accesDSRies etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm Nominal Size dia 518 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 519 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compresDSR, running the compresDSR for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compresDSR, tools & accesDSRies etc., all as per requirement and direction of Engineer-in-charge. 520 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 521 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 522 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).150 mm Dia 523 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.50 mm nominal size dia 524 Electric logging of bore hole 525 Supply and Installation of 1.5 HP Submersible pump set complete 526 Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. Capacity 25 Liters 527 M.S.GATESteel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 528 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 529 BOUNDRY WALLEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil 530 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 531 Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 532 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 533 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 534 Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete 535 Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers 536 Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts 537 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 538 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 539 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 540 Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost ofall material, labour, T&P etc. required for proper completion of work. 541 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 542 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 543 Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. 544 Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick.150 mm wide 545 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 546 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 547 SPLIT ACSupply & Installation of split direct expansion air conditioners suitable for operation on AC supply single phase 50Hz 230 V with hermetiaclly sealed compressor, with air colled condenser with DCinverter technology, motor capacitor and start run capacitors,relay and over load protection unit,with one indoor and outdoor unit wiil be plaved outside the room on the tessace to avoid noise including standard lenght of suitable size copper tubing covered with insulation tube ( High wall chorded/cordless) suitable capacity 3 Core sheathed /PVC copper cable and a operated wireless remote unit 1.5 TR. 548 Supply & installation testing commissioningof Voltage Stabilizer Complete in all respect. 549 Supply.installation testingandcommissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R 410A duly insulated with elastomeric nitrile rubber type tubular insulation of density 55+/- 10% Kg/m3 betweenindoor & outdoor units as per specifications.12.7 mm O.D. (Min. Wall Thickness- 0.80 mm. insulation -13 mm thick) 550 Supply.installation testingandcommissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R 410A duly insulated with elastomeric nitrile rubber type tubular insulation of density 55+/- 10% Kg/m3 betweenindoor & outdoor units as per specifications.6.4 mm O.D. (Min. Wall Thickness- 0.80 mm, insulation- 13 mm thick) 551 CENTAL ACSupply Installation Testing & Comissioning of Hitachi make Flexi split units energy efficient Twin Rotary Compressors with corded remote.A unique build, it epitomizes compactness and can replace 3 conventional system Outdoor unit with just one 7.5 Tr Outdoor unit& 2 conventional system Outdoor unit with just one 3 Tr / 4Tr / 5 Tr Outdoor unit .Individual circuit & compressor for each IDU unit.Which are operatable up to 52 degree C .High Effeciency Machines.Upto 4 TR 1 Phase Units ,5 TR & 7.5 TR Units 3 Phase.CONDENSER - 4.0TR HITACHI PAC CONCEALED (FSP) 552 CENTAL ACSupply Installation Testing & Comissioning of Hitachi make Flexi split units energy efficient Twin Rotary Compressors with corded remote.A unique build, it epitomizes compactness and can replace 3 conventional system Outdoor unit with just one 7.5 Tr Outdoor unit& 2 conventional system Outdoor unit with just one 3 Tr / 4Tr / 5 Tr Outdoor unit .Individual circuit & compressor for each IDU unit.Which are operatable up to 52 degree C .High Effeciency Machines.Upto 4 TR 1 Phase Units ,5 TR & 7.5 TR Units 3 Phase.CONDENSER - 5.0 TR HITACHI PAC CONCEALED (FSP) 553 CENTAL ACSupply Installation Testing & Comissioning of Hitachi make Flexi split units energy efficient Twin Rotary Compressors with corded remote.A unique build, it epitomizes compactness and can replace 3 conventional system Outdoor unit with just one 7.5 Tr Outdoor unit& 2 conventional system Outdoor unit with just one 3 Tr / 4Tr / 5 Tr Outdoor unit .Individual circuit & compressor for each IDU unit.Which are operatable up to 52 degree C .High Effeciency Machines.Upto 4 TR 1 Phase Units ,5 TR & 7.5 TR Units 3 Phase.CONDENSER - 7.5 TR HITACHI PAC CONCEALED (FSP) 554 SITC of Flexi Split Indoor Unit - ( FSP )EVAPORATOR - 2.5TR HITACHI COMPACT CASSETTE(FSP) - Panel size 3 FT X 3 FT 555 EVAPORATOR - 2.0 TR HITACHI COMPACT CASSETTE (FSP)- Panel size 2 FT X 2 FT 556 GAS TOPUP & COMMISSIONING OF SYSTEMFirst Starting of DUCTED / Fsp System including topping R410A gas per site requirments. 557 Supply installation testing and commissioning of Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perHITACHI STD. & specifications,all pipinginsidethe roomshallbe properlysupportedwithMShanger. 15.9 mm dia 19 mm thk. Insulation 558 Supply installation testing and commissioning of Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perHITACHI STD. & specifications,all pipinginsidethe roomshallbe properlysupportedwithMShanger.12.7 mm dia 13 mm thk. Insulation 559 Supply installation testing and commissioning of Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perHITACHI STD. & specifications,all pipinginsidethe roomshallbe properlysupportedwithMShanger.9.5 mm dia 13 mm thk. Insulation 560 Supply installation testing and commissioning of Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perHITACHI STD. & specifications,all pipinginsidethe roomshallbe properlysupportedwithMShanger.6.4 mm dia 13 mm thk. Insulation 561 Covering of Copper pipes NEAR Outdoor - OPTIONAL WITH EXTRA CHARGES 562 Providing and fixing rigid CPVC piping complete withfittings, supportsas per HITACHI STD.&specifications and duly Clamped. 25 mm dia 563 Providing and fixing rigid CPVC piping complete withfittings, supportsas per HITACHI STD.&specifications and duly Clamped. 32 mm dia 564 Providing and fixing rigid CPVC piping complete withfittings, supportsas per HITACHI STD.&specifications and duly Clamped. 40 mm diaDrain Hose Connector 565 supply & fixing of 4 c x 2.5 sqmm of Copper conductor cable for looping between indoor & outdoor DUCTED & FSP system - Make - RR Cabel , Polycab , EQUIVILANT 566 Minor Civil Work/ Wall cutting / Core Cutting - BY CIVIL CONTRACTOR 567 FURNITUREProviding and Supply Double Bed, Wooden Ply , PLPB Board, CRCA Pipe Frame , Powder Coated, PPCPShoes , Without Matress of size2040X1600X758 (Double BED) Design and approve as per architect incharge ( Geeken, Bernhardt , Godrej or Equivalent)HOSTEL 12 568 Providing and Supply Three Seater Sofa, Wooden Frame , SS Pipe Leg Frame , Sear Back Leatherite Tapestrywith leatherette finish (STANLEY 3 ) design as per incharge of architect (MAKE - GeekenGS 335 , Bernhardt , Godrej or Equivalent) 569 Providing and Wardrobe with Mirror, Wooden Ply , PLPB Board, CRCA Pipe Frame , Powder Coated,size900x600x1965(Wardrobe with Mirror) Design and approve as per architect incharge ( Geeken, Bernhardt , Godrej or Equivalent)STORAGE 15 570 Providing and Supply Two Seater Sofa, Wooden Frame , SS Pipe Leg Frame , Sear Back Leatherite Tapestrywith leatherette finish (HENLY 2 ) 1300X780X755 design as per incharge of architect (MAKE - GeekenGS 335 , Bernhardt , Godrej or Equivalent) 571 CAFETERIA+ ADMINProviding and Supply Café Table , SS Pipe Frame, PLPB Edge Banded Top (GC 9062) 1200X910X750as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 572 Providing and Supply Café Table , SS Pipe Frame, PLPB Edge Banded Top (GC 9062) 1800X910X750as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 573 Providing and Supply Café / Restrorent Chair ,Chome Plated Reducing Pipe Frame, Leatherite Tapestry Chrome Plated(GC 950)as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 574 Providing and Supply Reception Table,Particle Board Top ,(RECEPTION 2) W2400 X D700 X H1000 as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 575 Providing and Supply High Back Chair , pipe Chrome Arm ,Chrome plated pipe stand , leatherite Tapestry with Chrome plated Finish and Swivel tilt for Receptiondesign as per incharge of architect (MAKE - Geeken GS 335 , Bernhardt , Godrej or Equivalent) 576 Providing and Supply Wooden Storage and Partice Board of size ( 900x450x1200) (STORAGE 11) design as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 577 Providing and Supply Visitor Chair, PP Arm, Chrome Plated Pipe Stand, Seat & Back Leatherite Tapestry(GV 621)as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 578 DORMITORYProviding and SupplyBunk Bed, MS Powder Coated Frame, CRCA Sheet, without mattress (L 2060 X W 950 X H 2000) BUNK BED 2 579 Providing and Supply Steel Personal Locker, 2 Locker, 1 Hanging Rod,Thickness 0.8mm (GMS 51) W380 X D450 X H1800 as per incharge of architect (MAKE - Geeken, Bernhardt , Godrej or Equivalent) 580 Providing, fabricating and fixing/ erection of 6mm SS plate backlitted at desired location as per approved drawing of CULTURAL CENTER or as verified by the Department,having Helvetica Font with 72mm size Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge 581 Providing, fabricating and fixing/ erection of 6mm SS plate backlitted at desired location as per approved drawing of CULTURAL CENTER or as verified by the Department, in Hindi with 60mm size. Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge 582 Providing and fixing 300X300powder coated 10-12mm MS Signage at desired locations with letters (in english, hindi and Braille) and illustrations - etched, through cut, infilled or painted as per the design approved from Architect in charge, also including the cost of design, fabrication and onsite installation with all the necessary accesMRies and equipments for fixing on any surfaceas per drawing and design approved from Architect in chargeEnglish: Helvetica Font with min. 16 sizeHindi: Krutidev Fontwith min. 16 size 583 Providing and fixing powder coated MS Signage at desired locations of approved size for UP tourism Logo and illustrations - etched, through cut, infilled or painted as per the design approved from Architect in charge, also including the cost of design, fabrication and onsite installation with all the necessary accesMRies and equipments for fixing on any surfaceas per drawing and design approved from Architect in charge 584 TOURIST FACILITYProviding & fixing ofRED SANDSTONE/MS BENCHsize (1200 mm length and 600 mm and height 450 mm) with including ornamentation/Engraving/Embossing foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge. 585 Providing & fixing of SS Dustbin size 400Dia. And 900Height fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge. 586 Providing and fixing StandAlone Signage in Sandstone/Marble/Granite of approved thickness with powder coated 6-8mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size 587 Specification of Y-Drinking Water(Receiving, storing, handling, shifting, installation, testing & commissioning ofWAE. AENON.45.CHA Pou Water Station C.A, RO Processing Capacity 25LPH, size: 466X580X1445, Watt; 220v/50Hz, Cooling 480w, Hot 450W, net weight 110kg, in material SS 304, with 3 tap: Cold 20 Ltr,Ambient-25Ltr including all accessories complete in all respect etc. (Make -WAE/Voltas or Equivalent)) 588 Providing, fabricating and fixing installation of artistically evolved and adaption of Neeb Karori Spiritual Center LOGO near front mural wall in metal/ stone, as per approved design and location by Architect in charge 589 Designing, engineering, fabricating, and finishing of parametrically evolved Neeb Karoori inspired abstract Installtion of 1500X2500mm height 2500mm with integrated lighting having self-sustaining structure supported at base, fabricated in 2.5mm Stainless Steel (304 Grade) Sheet, using Laser Cutting, bending, welding and parametric assembly of open joints, and mirror finishing with gold pigmented PU coating at desired location as per approved drawing to the complete satisfaction of Architect in charge. Also including the cost of providing and fixing/erection at site complete to the entire satisfaction of the Architect, complete in all respects. 590 Providing, supplying, designing, fabricating and fixing of signage and information board with Text and Illustrations as per approved location and drawings & design of Architect in chargeProviding and fixing 450X900 powder coated 10-12mm MS sheet and 25mm Corian Signage at desired locations with letters (in english, hindi and Braille) and illustrations - etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accesMRies and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 16 size Hindi: Krutidev Fontwith min. 16 size 591 SOUND SYSTEMSupply, Installation, testing and commissioining of Full range wall mount loudspeakerwith1 x 4.5 driverin a ported enclosure; Frequency Response : 80Hz-17kHz; Nominal Dispersion :125°H x 125°V; Power handling capacity : 40W; Nominal Impedance : 8O or 70/100V; Max SPL :103dB; Sensitivity :87dB; Installation : Indoor and Outdoor. Model DS 40SE Make Bose/ L-Acoustic/ D&B 592 Supply, Installation, testing and commissioining of Integrated zone amplifier having 6 inputs : 2 balanced and 2 unbalanced line inputs, 1 balanced page input and 1 balanced direct input; Frequency response : 55Hz-20kHz; Power : 2 x 120W @ 70/100V; Total harmonic distortion (THD+N) : = 0.3%; Dynamic Range : 88dB. Model: IZA 2120 HZ, Make: Bose/ L-Acoustic/ Powersoft 593 Supply, Installation, Testing and Comissioning of CD/DVD Player with USB Input. Model: CDMP 1500 Make Sony/ Philips/ Gemini/ Tascam 594 Supply and laying of 2 core 2.5 sqmm Armoured loudspeaker cable. Make: Klotz / Beldon / Krystal 595 Supply and fixing ofUL listed Connectors & Patch Cables/Connectors for interconnection of all equipments.Make: Neutrik / Amphenol 596 Supply, Installation, Testing and Comissioning of 15U Equipment Rack for housing all rack mountable equipments with front glass door; heat dessipation fans; internal lights; movement wheels, power distribution units etc. complete with standard accessories. 597 Supply, Installation, testing and commissioining of In Ground loudspeaker with frequency response of 70Hz to 10kHz; Nominal dispersion of 360H X 50V; Sensitivity of 87 dB SPL; Max SPL of 100 dB SPL; Long term power handling is of 80W@ 4 Ohm; Transformer taping can be done; Enclosed in a glass- reinforced polypropylene textured; Environmental Outdoor per IEC 529 IP35. Model: 360P Series II Make: Bose/RCF/ Equivalent 598 Supply, Installation, testing and commissioining of 6 channel mixing console of 2 mono inputs&2 stereo line inputs; Frequency Response : 10Hz-55kHz; Total Harmonic Distortion (THD+N) : 0.03% ; Power supply : External ; Phantom power : +48V ; Power consumption : 17W. Make: RCF/Allen&Heath/ Yamaha 599 Supply, Installation, Testing and Comissioning of Gooseneck Microphone with table top on/off switch : Cardioid polar pattern; Frequency Response: 50 Hz to 20 kHz; Impedance <100 Ohms; Max Sound Pressure level: 130 dB; RF shielding against intermodulation from wireless devices with MAT 133-S: a table stand with microphone modes like Toggle on/off, Push to mute, Push to talk. Model: MEG 14-40 + MAT 133S-B Make: Beyerdynamics/ Shure / Sennheiser 600 Supply, Installation, Testing and Comissioning of CD/DVD Player with USB Inputcomplete with standard accessoriesas per the tender specifications. Make: Sony/Philips/Gemini/Tascam 601 Supply and laying of 2 core 2.5 sqmm Armoured loudspeaker cable.Make: Klotz / Beldon / Krystal 602 Supply and laying of 2 core shielded PVC insulated Cu conduction microphone cable. Make: Klotz / Beldon / Krysta 603 Supply and fixing ofUL listed Connectors & Patch Cables/Connectors for interconnection of all equipments. Make: Neutrik / Amphenol 604 Supply, Installation, Testing and Comissioning of 9U Equipment Rack for housing all rack mountable equipments with front glass door; heat dessipation fans; internal lights; movement wheels, power distribution units etc. complete with standard accessories. 605 Supply& Installation of WiFiHotspot at various location with controllerbased etc all complete in dircection of engineer in charge. 606 DG SetSupply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and high temperature trippin DG Set with AMF Control Panel 63 KVA 607 G.S.T Extra as per applicable
Contract Date: Jul 27, 2024 Contract Value : 6.61 Crore
Government Departments No of Bidders 2
Uttar Pradesh View Result →
17.
Public Administrative Department #3687189 AOC
Supply & Installation Commissioning And Comprehensive Support Of Machinery For Common Facility Centre Of Stitchers Garments Manufacturing And Home Furnishing Association Chalisgaon, Dist.- Jalgaon, State-Maharashtra, India.1 Fabric Inspection  Fabric Inspection Cum Relaxing Machine- 220Cm- Width With Air Blow- Maximum Speed 150 Mtrs / M, Average Speed 40M / M, Maximum Width 180 Cm To 220 Cm, Maximum100kg, Maximum Roll Dia 50Cm Capacity 2 Pattern Making  Cad-Software ( Pds+Bn+Vis ) -Automatic Digitizing, Native Files Importations, Pattern Creation, Modification, Adjustment, Size Grading, And Technical Sheet, Manual And Automatic Nesting, Queue Management. Made In Italy 3 Automatic Fabric Cutting  Plotter 180- 2 Head -Power Consumption 70W / 180 W, Interface- Usb Or Lan ( Optional ) , Inkjet -Hp2 / 4, Paper 18-120 Gr /  Automatic Spreader-Maximum Speed 100Mtrs / Min, Width Available 180-230Cm, Max.Capacity 100Kg, Maximum Roll Dia- 50Cm, Voltage 400V 3Ph 50 / 60 Hz, Spreading Modes, Face Up / One Way And Zig Zag With Or Without Ends Cut ( Lap Laying ) Cradle With Double Pvc Belt, Omron Plc, Auto Diagnosis System, Electronic Tension Free Device, Auto Edge Alignment By Photocells, Encoder Device, Fabric Usage Report -Made In Italy  Air Blow Table ( 1Mtrx1.8Mtrx30 ) Air-Blowing Spreading Table With Metalic Oven Painted Structure. Table Top In Medium Ecotype Laminated In White Colour And Holes To Blow Air, Stell Side Rails 60X 30Xx2mm For Morgan Spreaders To Run Suction 6Of 6 M, Complete With Blowing Motor And Electric Panel 4 Manual  Spreading Machine Accessories Fabric Cutting  Straight Knife Cloth Cutting Machine - 8Engineered With A Low Profile, Polished And Streamlined Baseplate Designed To Reduce Friction And Distortion Of Material, Regardless Of The Number Of Plies-Straight Knives – High-Speed Reciprocating Cutting Technology Designed For Cutting Patterns, As Well As Straight Lines In Multiple Thicknesses Of Material-Made In Usa  Staright Knife Cloth Cutting Machine -8Blue Streaks Engineered With A Low Profile, Polished And Streamlined Baseplate Designed To Reduce Friction And Distortion Of Material, Regardless Of The Number Of Plies- Made In Usa  End Cutter -Drastically Reducing The Waste That Ends Up On The Cutting Room Floor, The Falcon Series Eliminates The Need For Excessive Selvage. Available To Cut 48-144 Inch Wide Material ( 1.22- 3.66 M ) , These Systems Are Known For Their Quality, Versatility And Ease Of Use. The Range Of Models And Configurations Ensures That Eastman Has The Right Equipment For Your Material And Specifications  Band Knife - Table Size-1200Mmx1600mm, Cutting Capacity-180Mm, Variable Speed , Arm Size 700Mm  Round Knife -Round Knives – Commonly Used To Cut Straight Lines Or Large Radius Curves  Cloth Drill -Drills / Marking / Special Applications – Make Buttonholes, Darts, Or Other Markings; Pattern Perforating, Bundling, Strip Cutting, And Rag Manufacturing Home Textiles  Needle Detector -Magnetic Induction, Buzzer, Lamp-Alarm , 32 Mtrs Per Minute , Detecting Height- 100Mm  Handy Needle Detector  Machine Therefore Production Is Greatly Increased. The Automatic Belt Warping Prevention Device Keeps Both The Upper And Lower Belts In The Same Position. Using The Feedback System, Damage Is Prevented. ( Patent Pending ) Using The Electronic Thermostat And The Ssr, The Temperature Difference’S Range Is Kept At ±3℃. The Ssr’S Electronic Parts Have No Contact Points Making For Durability. Various Stackers Can Be Used With This Machine. This Machine Has A Front Conveyor Belt Which Greatly Increases Production Levels. The Rotary Strip Off Device Can Be Attached As Optional Equipment. By Pushing The Heater Control Switch The Temperature Of The Upper And Lower Or Front And Rear Heater Can Be Easily Controlled. This Means Various Materials Can Be Used Safely. The Pressure Roller Is Covered With A Layer Of Silicon Rubber. The Upper And Lower Pressure Rollers Are Completely Separated When The Pressure Is Set At 0. The Heating Plate Is Covered With Special Hard Alumite, Making It Durable. The Exchange Of Belts Is Very Easy. The Belt Stopping Device Stops The Belt Automatically If The Belt Warps Therefore Protecting The Belt. The Entrance Of The Feed In Point Can Be Adjusted Easily According To The Thickness Of The Material And Interlining Being Used. An Anti-Puckering Roller Is Installed In This Machine. This Roller’S Position Can Be Adjusted. Wing Tables Can Be Attached To The Work Table. When These Tables Are Not In Use, They Can Be Folded Down. ( Option )  6 Head 12 Colour Computerized Emboidery Machine -Needle: 12 Head: 06 Area: 400 850 1300 Stable Running Speed: 1200Rpm Maximum Speed: 1400Rpm Dahao 10 Inch A18 Computer With Head Selection Original Dahao Servo Motor For Main Shaft Motion – 3.0Kw Original Dahao Servo Motor X-Y Shaft Motion Servo Motor Cutter For Silent Trimming Action As Well As Perfect Trimming Effect Utc And Uth ( Under Thread Breakage Detecting And Upper Thread Holding Facility ) Double Cam Triple Lever High Speed Head With Jump Solenoide Original Japan Hirose 1.6X Jumbo Rotary Hook, Head To Head Oiling Facility Latest 5Cm Linear Guide Rail With Leveling Plate To Sure Exact Parallel And Levels Ultra Si E Collar Bearing Applied For Unix Guide Rail Base Ultra Si E Shaft Applied On Main Shaft Special Big Foot Pad To Run Machine Stable At High Speed With Standard Spare Parts And Accessories  8 Head Chennile Embroidery Machine ( China ) - Original Dahao System, Dahao Servo Motors, Latest High Speed Chenille Heads And Flat Bed Embroidery Machine With 9 Colour , With Standard Accessories  18- Head, 12 Colour Embroidery Machine With Double Sequins &Cording Needle: 12 Head: 18 Area: 4001300 Stable Running Speed: 1200Rpm Maximum Speed: 1400Rpm Dahao 10 Inch A18 Computer With Head Selection Original Dahao Servo Motor For Main Shaft Motion – 3.0Kw Original Dahao Servo Motor X-Y Shaft Motion Servo Motor Cutter For Silent Trimming Action As Well As Perfect Trimming Effect Utc And Uth ( Under Thread Breakage Detecting And Upper Thread Holding Facility ) Double Cam Triple Lever High Speed Head With Jump Solenoide Original Japan Hirose 1.6X Jumbo Rotary Hook, Head To Head Oiling Facility Latest 5Cm Linear Guide Rail With Leveling Plate To Sure Exact Parallel And Levels Ultra Sie Collar Bearing Applied For Unix Guide Rail Base Ultra Sie Shaft Applied On Main Shaft Special Big Foot Pad To Run Machine Stable At High Speed With Standard Spare Parts And Accessories Screw Air Compressor With 500 Ltr Tank, Air Filter And Dryer E4 Advance Digitizing Soft Ware For Embroidery Design Punching Carding And Pillow Filling Machine With Pillow Vaccum Machine Computerized Frame Type Quilting Machine ( Lifting Head ) . Richpeace 1:1 Design, Fixed Frame, Moveable Sewing Head And Saddle, Improved Quilting Precision And Max. Quilting Si E Up To 3.2M. 2. Minimied Installation Area, Solves The Traditional Machine Problem Of Large Area Of 2Times Or 4Times More, And Takes Full Use Of The Plant. 3. Max. Speed Is 3000Rpm, Suggested Working Speed Is 2500Rpm To 2800Rpm. 4. Automatic Lifting Head, Sewing Head Will Lift Up Automati Cally After Quilting For Frame Changing Easily. Special Designed Sewing Head With Independent Presser Foot Drive Is Suitable For Different Material. 5. Retractable Quilting Frame, Can Be Adjusted Freelyaccording To The Required Quilting Sie. 6. Four Japanese Panasonic Servo Motors Provide Powerful And Accurate Driving Force. 7. The Gap Between Needle And Rotary Hook Is Not The Needle To Needle Design, Which Reduces The Wear Between The Rotary Hook And Prolongs The Service Life Of The Hooks. 8. Japanese Koban Jumbo Rotary Hook And Bobbin Case. 9. Broken Thread Detection: Automatically Stop After Thread Is Broken, And The Machine Will Return Back The Broken Point To Quilt After Threading Automatically F Multi Needle Quilting With Embroidery Machine- Single Roll, Long Roller, Designed For Home Textile Wide Fabric Roll Application. Automatic Alternative Heads Feature, For Super Big Size Pattern, Automatic Thread Trimming, Colour Changing Or Pattern Spanning With Auto Thread Cutting, Reduce Manual Trimming Work.Automization Oiling System, Lubricating Machine Head And Rotary Hook Components Round, Longer Machine Life -Time.Four Needles Each Head, For Multi Colour Product.Japan Kiban Jumbo Rotary Hook With Richpeace Professional Design Software . Mainly For Summer Quilt, Bed Cover, Pillow Case, Curtain, Mattress, Protective Pad...Etc Direct Drive Single Needle Lock Stitch Machine Auto Thread Trimmer, Electric Auto Foot Lifter , 5000 Rpm , Complete Set  Direct Drive, Electronic 3 Step Zig Zag Machine, Complete Set With Inbuilt Designs , Complete Set  Single Needle Straight Lock Stitch Machine With Edge Cutter Speed 4500Rpm , Complete Set  Semi Dry Head Double Needle Lock Stitch With Fix Bar And Thread Trimmer , Complete Set  Semi Dry Head Double Needle Lock Stitch With Split Bar And Thread Trimmer, Complete Set  2 Needle Feed Off The Arm With Double Chain Stitch Machine With Cloth Puller, Complete Set  Computer Controlled Bartacking Machine, 3500Rpm, Complete Set  Uter Controlled Lock Stitch Button Holing Machine, Complete Set  Computer Controlled, Direct Drive , Lock Stitch Button Sewing, Complete Set  Computer-Controlled Eyelet Button Hole Machine With Thread Trimmer, With Sub Merged Table, Complete Set  Direct Drive Two Needle Four Thread Overlock Machine With Speed 7000 Rpm And Dlc Coated Needle Bar And Upper Looper Assy, Castor Wheels -Complete Set Made In Japan  Direct Drive Two Needle Five Thread Safety Stitch Machine With Speed 7000 Rpm And Dlc Coated Needle Bar And Upper Looper Assy-Castor Wheels, Complete Set Made In Japan  Direct Drive 3 Needle 5 Thread Flatbed Flat Lock Machine For Plain Seeming, & Tape Binding & Auto Foot Lifter With Conversion Kit For Binding & Cover Stitch, Castor Wheels, Complete Set - Made In Japan  Direct Drive 3 Needle 5 Thread Cylinder Bed Flat Lock Machine With Left Hand Fabric Trimmer, And Pneumatic Top And Bottom Thread Trimmer, Castor Wheels, Complete Set - Made In Japan  4 Needle , Flatbed Multi Functional Machine With Smooth Puller For Shirt Fronting, Castor Wheels, Stitching Machines Complete Set-Made In Japan  4 Needle , 8 Thread , Flat Bed , Double Chain Stitch Machine With Rear Puller For Attaching Elastitc , Castor Wheels, Complete Set, Made In Japan  4-6 Needle , Flatbed , Double Chain Stitch Machine With Puller For Waist Band Attaching , Castor Wheel, Complete Set-Made In Japan  2 Needle , Flat Bed , Making Belt Loop Machine With Front Fabric Trimmer, Catrol Wheel, Complete Set Value Addition 4 Needle , 8 Thread , Flat Bed , Double Chain Stitch Machine With Rear Puller For Attaching Elastitc , Castor Wheels, Complete Set, Made In Japan 4-6 Needle , Flatbed , Double Chain Stitch Machine With Puller For Waist Band Attaching , Castor Wheel, Complete Set-Made In Japan 2 Needle , Flat Bed , Making Belt Loop Machine With Front Fabric Trimmer, Catrol Wheel, Complete Set 12 Needle , Flatbed, Double Chain Stitch Machine For Pin Tucking Can Be Changed To 2.5 And 8Mm By Changingthe Nail Blades Castor Wheels, , Complete Set , 3500Rpm, Made In Japan Collar Turn And Block Cuff Blocking Automatic Snap Fastner With Feeder ( Pneuamtic ) Gle Needle Double Chain Stitch Machine With Puller , Complete Saddle Stitch , Complete Set Auto Lock Stitch Pocket Welting Machine, For Double Welt And Single Welt , Made In Germany Fixed Needle Bar, For Straight Pockets, Suited With Optional Items For Trouser Manufacturing. Basic Equipment: Brother Original Sewing Head B8422-403 Sewing Head With Fix Needle Bar - Double Welt &-Single Pneumatic Thread Trimmer , - Direct Drive, Alternating Current 220 V, 50-60 Hz Microprocessor Control Box Free Programmable With Liquid Crystal Display And Monitor , - Main Clamp Feed Through Regulate Step Motor And Automatic Variable Length Adjustment For 20-200 Mm - Separate Lowering Of Feeding Clamps Programmable - Reduced Cycle Time Of The Machine Through A Higher Clamp Speed - High Precision Mitre Cutting Of The Machine Through Programmable Mitre Knife Location Regulate Through Step Motor. - Quick Adjustment Of The Mitre Knife Programmable In Control; 0, 1 Mm Steps By 10 Mm Adjustment Length. - Sideways Mitre Knife Adjustment By Eccentric - Mitre Knife Holder With Adjustable Cut Width , - Sewing Through Front - And End Tack Or Stitch Condense Programmable, - Pocket Pouch Clamp For Loading Pocket Pouches - 5 Line Laser Pluggable ( Separate Programmable ) - Piece Counter , - Airgun With Hose , - Top Thread Monitor  Model Number -F2130-Printer Width Printing Technology Print Speed Paper Handling Connectivity Power And Operating Requirements Printer Dimensions Printhead Nole Configuration Maximum Resolution Production ( 2 Pass ) Production ( 4 Pass ) Production ( 6 Pass ) Production ( 8 Pass ) Paper Handling Printable Area Media Width Media Thickness Control Panel Printer Interfaces Printer Languages Memory Software Power Requirements Power Consumption Recommended Operating Temperature & Humidity Dimensions Weight Ac 100-120V Ac200-240V 50 / 60H Operating: Approx. 570W; Ready: Approx. 340 W; Sleep: Approx. 14 W; Power Off: Approx. 1.0 W Operating: 15°C To 35°C, Storage: -20°C To 60°C 2, 620 X 934 X 1, 332 Mm ( Wxdxh ) 290Kg ( Without Ink ) Operating: Approx. 600W; Ready: Approx. 380 W; Sleep: Approx. 14 W; Power Off: Approx. 1.0 W Hi-Speed Usb, 100Base-Tx 1000Base-T Standard: Esc / P Raster 512Mb Main + 128Mb Network Bundled In Cd ( Windows Only ) : Cd Installer, Epson Communication Driver, Epson Manual Launcher, Operators Guide, General Information, Epson Control Dashboard, Epsonnet Setup, Epsonnet Config, Epsonnet Print, Software Updater, Dvd ( Epson Edge Print Bundle Sku Only ) Epson Edge Print, Epson Control Dashboard, Epson Communication Driver Web Delivery ( Mac And Windows ) : Windows And Mac: Cd Installer, Epson Communication Driver, Epson Manual Launcher, Operators Guide, General Information, Epson Control Dashboard, Epsonnet Setup, Epsonnet Config, Epsonnet Print, Software Updater, Lfp Accounting Tool Rear Roll Feed ( 2” / 3” Core With Max 250Mm Diameter And Up To 45Kg ) ; Auto Take- Up Reel Max Printing Width: 1615.6Mm; Side Margin: 5Mm Both Sides, 10Mm With Media Holding Guides 300.0 Mm ( 11.8” ) - 1625.6 Mm ( 64” ) Up To 1 Mm 2.7” Colour Lcd Dual Precisioncore™ Tfp® Printhead 360 Noles X Channels X 2 Head 720X1440 Dpi Up To 60.1 M2 / H 720 X 720 Dpi ) Up To 29.9 M2 / H ( 720 X 720 Dpi ) Up To 20.7 M2 / H ( 720 X 1440 Dpi ) Up To 15.6 M2 / H ( 720 X 1440 Dpi ) Up To 62 M2 / H ( 360 X 720 Dpi ) Up To 32.1 M2 H ( 720 X 720 Dpi ) Up To 21.9 M2 / H ( 720 X 720 Dpi ) Up To 15.8 M2 / H ( 720 X 720 Dpi ) 360 Noles X 5 Channels X 2 Head 64” Sc-F9430 ( C11cj00402 ) Sc-F9430h C11ch99402 ) Sc- F9430 ( C11cj00402 ) Weight: 290Kg Without Ink ) Sc-F9430h ( C11ch99402 ) Weight: 290Kg Without Ink ) Supplies & Optional Accessories Maintenance Kit C13s210063 Head Cleaning Set C13s210051 Waste Ink Bottle C13t724000 Cleaning Stick C13s090013 Clean Room Wiper C13s090016 Ink System Ink Type Colours Ink Capacity Epson Ultrachrome™ Ds Dye- Sublimation Ink 4 Colours - Cyan, Magenta, Yellow, High Density Black Cyan, Magenta, Yellow, High Density Black: 1100Ml Ink Pouch Fluorescent Yellow, Fluorescent Pink: 1000Ml Ink Pouch Epson Ultrachrome™ Ds6 Dye- Sublimation Ink 6 Colours - Cyan, Fusion Press -Fusing Press ( Made In Italy ) : Special Calender For Pieces Or Continuous Fabrics, Used For : • Transfer Printing • Direct Inks Reactivation • Thermosetting - Heatsetting Versatile And Polyvalent Calender, Developed For Transfer Printing Of All The Follows Work Conditions, According To Required Options: • Printing Paper In Roll And Material To Be Printed In Roll • Printing Paper In Roll And Material To Be Printed In Pieces • Printing Paper In Sheets And Material To Be Printed In Pieces 1. Characteristics Of Printing Cylinder: 1.1. Diameter : 200 Mm ( 7, 87“ ) . 1.2. Width: 1.800 Mm ( 70, 87“ ) . 1.3. Working Width: 1.500 Mm ( 59, 06“ ) / 1.600 Mm ( 62, 99“ ) . 2. Heating System And Temperature Control: 2.1. The Cylinder Is Heated By One Resistor ( Heating Element ) In A Vacuum Sealed Oil Bath, In Complete Absence Of Air And Pressure. Monti Antonio S.P.A System. 2.2.The Temperature Of The Cylinder Is Set By The Touch Screen And Regulated By An Electronic Card. The Temperature Controls Equipped With Temperature Alarm System And A Limitation System Of Maximum Temperature ( 230 °C ) . 3. Tension Controls: 3.1. Tension Control For Printing Material In Roll: Entry: Brake With Manual Adjustment Exit: Winding With Pneumatic Device 3.2. Tension Control For Printing Paper In Roll: Entry: Disk Brake With Manual Adjustment Exit: Winding With Pneumatic Device 3.3. Tension Control For Protection Paper: Entry: Disk Brake With Manual Adjustment Exit: Winding With Pneumatic Device 4. Other Devices Into Machine: 4.1. Short Front Working Table, 800 Mm 4.2. Single Motor 4.3. Nomex Felt With Manual Tension Adjustment System And Automatic Felt-Centering Device All Data And Technical Features Are Purely Indicative And Subjected To Changes Without Prior Notice Model 180 T 4.4. Incorporated System Of Felt Protection In Case Of Black Out And / Or Compressed Air Lack 5. Technical Data : 5.1. Installed Power: 10 Kw / H 5.2 Determining The Fabric Yield In G / M2 ( Gsm ) Accurately. Suitable For Woven, Non-Woven And Knitted Fabrics. Sturdy High Grade Mild Steel Construction. Manually Operated, Fixed Diameter, Monoybody Aluminum Alloy Structure With Controlled Mass. Specially Designed Blade Mechanism For Rapid And Accurate Cutting. No Additional Rubber Pad And Cutting Blade Arrangement For Longer Life Usage. Suitable For Cutting Any Type Of Material Including Film, Form, Carpet, Paper And Leather. T E C H N I C A L D A T A Cutting Sie : Φ 112.82 Mm ( 4.44 Inch ) Accuracy : ± 0.2 Mm Cutting Depth : 10 Mm Cutting / Specimen Area : 100 Cm2 ( 1 / 100Th Of A Square Meter ) Cutter Life : Maximum 50000 Stokes Aaplicable Standard ( S ) -Lab Testing Machine S Shrinkage Measuring Template :Measure The Dimensional Changes In Fabrics After Laundering, Dry-Cleaning Etc., Ergonomically Designed And Direct Measurement Of Dimensional Change ( Shrinkage & Stretch % ) For All Types Of Fabrics. Template And Scale Made Up Of Transparent Polymer Plate To Apply Standard Pressure On Test Specimen. Calibrated Scale To Check The Shrinkage Directly Up To 15%. Two Fine Tipped Black And Blue Ohp Markers For Accurately Marking On The Dark Colored Fabrics. T E C H N I C A L D A T A Capacity : Up To 15 % ( Shrinkage And Stretch % ) Template Length : 250, 350 & 500 Mm ( Slot To Slot ) Scale Distance : 250, 350 & 500 Mm ( Slot To Slot ) Applicable Standard ( S ) : Aattc 135 / 150 / 160 / 179, Iso 3759 And Bs 4931 Physical Dimensions : Sie ( Wdh ) : 600 X 600 X 6 Mm Weight : 2.5 Kg Digital Bursting Strength -70Kg / Cm2to Determine The Bursting Strength Of All Kind Of Fabrics, Papers And Boards. Diaphragm Bursting Method; Motoried Hydraulic System With Constant Pumping Rate. Thin Diaphragm For Low Bursting Strength Measurement. High Precision Digital Read-Out In Kg / Cm2 & Psi. User Friendly Menu Settings With Single Push Button Switch Operation. Separate Testing Functions For Fabric, Carton And Foil Sheets. In-Built Tare Pressure ( Diaphragm Correction ) Program Ergonomically Designed With Modern Aesthetics. T E C H N I C A L D A T A Capacity : 0.5 To 70 Kg / Cm2 ( 7.0 To 1000 Psi ) Range : 2.5 To 70 Kg / Cm2 ( 35 To 1000 Psi ) With Standard Diaphragm 0.5 To 10 Kg / Cm2 ( 7.0 To 140 Psi ) With Thin Diaphragm Accuracy : ± 1 % Fs, Readability : 0.01 Kg / Cm2 – Below 10 Kg / Cm2 0.1 Kg / Cm2 – Above 10 Kg / Cm2 Display : Digital Alpha-Numeric Lcd Display Clamp Opening 30.0 Mm Throat Depth : 100 Mm Test Diameter : Ø 30.5 Mm Test Fluid : Glycerin; Filling Capacity: 95 Ml Test Specimen Sie : 100 X 100 Mm ( Minimum ) Hydraulic Flow Rate : 95 ± 5 Ml / Min Drive Motor : 0.27 Kw, 1440 Rpm Single Phase Ac Induction Motor Power Supply : Single Phase 220Vac @ 50H Consumption : 300 Watts Applicable Standard ( S ) : Astm D3786 ( Hydraulic And Work Factor Of Fabrics. Ergonomically Design With Modern Sophisticated Look. Elmendorf Method, Supplied With Calibration Weight And Augmenting Mass To Test Up To 6400 Grams. Fabric Below 320 Gf Can Be Tested With Multiple Specimens. Tearing Force Can Be Calculated With Simple Calculations. Accurate Slit Cutting Blade With The Special Care To Safety Of The Operators. T E C H N I C A L D A T A Capacity : Up To 100 % Of Fsr ( Full Scale Readings ) Measuring Range : 20 To 80 % Of Fsr. Accuracy : ± 1% Of Fsr Download Pressure : 1600 Gf ( Without Augmenting Weight ) 3200 Gf ( With Augmenting Weight “A” ) 6400 Gf ( With Augmenting Weight “A+B” ) Tearing Distance : 43.0 ± 0.15 Mm Slit Sie : 20 Mm ± 0.2 Mm Distance Between Clamps : 2.5 Mm ± 0.3 Mm Specimen Template Side : Fabric Stretch And Recovery Meter : Determine The Stretch And Recovery ( Elasticity ) Of Textile Fabrics ( Knitted And Woven ) , Where Extension At Break Is Not Required. Table Top; Simple And Economical; Easy To Use Manual Operation. Self- Aligning Flat Faced Stainless Steel Clamps With Pu Grips For Better Gripping. Sturdy Loading Frame Fitted With Screw Tensioning Device. Calibrated Dead Weights For Accurate Loading; Specimen Template For Quick Sample Preparation. T E C H N I C A L D A T A Load Application : By Hanging Calibrated Dead Weight ( S ) Loading Range : 1 To 5 Kg ± 2% ( Applied In Steps Of 1 Kg ) Test Length : 1 ) 200 Mm For Woven Fabrics 2 ) 75 Mm For Knitted Fabrics Extension Range : 50 % For Woven Fabrics And 300 % For Knitted Fabrics Specimen Clamping Area : 75 X 10 Mm Applicable Standard ( S ) : Bs 4294 Physical Dimensions : Sie ( Wdh ) : 650 X 150 X 150 Mm Weight : 15 Kg Well As Pilling Resistance Of All Kind Of Fabrics. Ergonomically Designed With Modern Aesthetics And Accurate Lissajous Figure. Martindale Abrasion Method With 4 Working Heads And Individual Selectable Working Pressure Of 3 / 9 / 12 Kpa. Grading The Specimen Against Photographic Standards For Woven And Knitted Fabrics. Digital Controls And Unique Design Supplied With Specimen Cutter For Ease Of Operation. Supplied With All Accessories Including Two Sample Cutters Φ 140 Mm & Φ 38 Mm With Spare Blades & Cutting Materials To Make Sample Conveniently. T E C H N I C A L D A T A Capacity : One To Four Specimen At A Time Measuring Range : 99999 Times ( Continuous Cycle ) Working Pressure : 3 Kpa, 9 Kpa & 12 Kpa Rotational Speed Of Outer Pegs : 47.5 ± 2.5 Rpm Total Stroke Of Outer And Inner Pegs : 1 ) 60.5 ± 0.5 Mm ( Abrasion ) 2 ) 24.0 ± 0.5 Mm ( Pilling ) Circumferential Parallelism : ± 0.05 Mm Of Sample Holders To Abrading Tables Power Supply : Single Phase 220Vac @ 50H; Ici Pilling Tester -2 Boxes -Features : Determine The Tendency To Form Pills. Test Specimens Taken From The Fabric Sample Are Rubbed Against Each Other Under Controlled Conditions. Grading The Specimen Against Photographic Standards For Woven And Knitted Fabrics. Ici Pillbox To Replicate Pilling On Fabric. State-Of-Art Microcomputer Solid-State Controlled Circuitry With User-Friendly Menu Driven Operating System. Latest Engineering Components For The Easy And Maintenance Free Operation. Specially Designed Two Wooden Pilling Stations For Better Efficiency Of Work. Alphanumeric Lcd Display Screen With Backylight Illumination. Inching Facility To Easily Assess For Sampling. T E C H N I C A L D A T A Pilling Boxes Sie : 235 X 235 X 235 Mm ( As Per Standard ) Cork Liner Thickness : 3.2 Mm ( As Per Standard ) Boxes Rotation Speed : 60 ± 2 Rpm ( As Per Standard ) Test Specimen Sie : 125 X 125 Mm Rubber Tube Sie : Length : 140 ± 0.5 Mm; Diameter : 31.5 ± 0.5 Mm Wall Thickness : 3.2 ± 0.5 Mm; Weight : 52.25 ± 0.5 Gram Control System : Microcomputer Based Solid-State Control Circuitry Power Supply : Single Phase 220Vac @ 50H; Consumption : 100 Watts Applicable Standard ( S ) : Bs En Iso 12945- 1 ( Part-1 ) , Bs 5811 & Is 10971 Physical Dimensions : Sie ( Wdh ) : 860 X 790 880 Mm Weight : 50 Kg Digital Thickness Gauge :Determine The Thickness Of Woven, Knitted, Coated Narrow Fabrics, Tapes, Ribbons, Braids, Films, Glass Fabrics, Glass Tapes.  An Inexpensive Model With Ease Of Operation.  Range : 0 - 10 With 10 Micron Resolution.  Portable & Handy To Carry Anywhere.  Supplied With Two Pressure Foot Of Different Sie For Different Type Of Fabrics.  A Standard Pressure Weight Is Provided With The Instruments For Accurate Result.  Digital Display For Measuring Thickness In Millimeters. T E C H N I C A L D A T A Measuring Range : 0.010 To 10.00 Mm Measuring Accuracy : ± 0.01 Mm ( Or ) ± 10 Microns Readability : 0.01 Mm Diameter Of Anvil : Top : 75 ± 0.2 Mm Pressure Foot : A ) Φ 28.7 Mm B ) Φ 25.0 Mm Pressure Weight : A ) 1 Kpa B ) 5 Kpa C ) 10 Kpa D ) 4.14 Kpa Applicable Standard ( S ) : Astm D1777, Bs 2544 / 3424 / 4051 / 4098 / 4223 / 29073, Flammability Tester -45°Specialied Equipment To Determine Flammability Of The Fabrics. Latest Ergonomically Design With Modern Aesthetics. Stainless Steel Construction, Glass Observation Window And Digital Timing Control. Fine Gas Control System To Regulate The Flame Length. Movable Sample Mounting Mechanism To Adjust The Sample As Per Standards. Specially Designed Digital Re-Settable Timer. Refilling Of Gas Container With Mechanical Valve. T E C H N I C A L D A T A Specimen & Template Sie : 150 X 50 Mm Specimen Flame Time : 1 Second ( As Per Standard - To Be Change The Seconds As Per Application ) Flame Height : 16 Mm ( 5 / 8 Inch ) Height Adjustment Of Flame : 19 Mm ( 3 / 4 Inch ) Burner Specimen Distance : 8 Mm ( 5 / 16 Inch ) Digital Timer : 0 - 99.9 Sec; Least Count : 0.1 Second Testing Time : Depends Upon To The Test Specimen / Procedure Sample Holder Sie : 165 X 50 Mm Applicable Standards : Astm D1230 And 16 Cfr Part 1610 Power Supply : Single Phase 220Vac @ 50H Physical Dimensions : Sie ( Wdh ) : 330 X 230 X 650 Mm Weight : 15 Kg ( Accessories Excluded ) Fabrics And The Flame Propagation Rate Onto Vertically Oriented Textiles Materials. Cabinet Fabricated Out Of High Quality Brushed Mild Steel, Glass Observation Window And Back Wall Painted Black For Easy Test Viewing. Specially Designed Two Different Burners And Angle Adjustment ( Vertical, 30° & Horiøontal Position ) With Gas Pilot Light. Counting Timer Automatically Activated At Time Of Flame Impingement. Specimen Holder And Burners Are Dependent On The Test Standard And Must Be Specified. Flame Height 40 ± 2 Mm Adjusted By Mechanical Valve - Flame Height Gauge Included. Gas Container Refillable - With Mechanical Valve. T E C H N I C A L D A T A Specimen & Template Siøe : 300 X 76 Mm ( As Per Standard Astm D6413 ) 200 X 160 Mm ( As Per Standard Bs 5867 ) 560 X 170 Mm ( As Per Standard Bs 5867 ) Flame Time Of The Specimen : 12 Second ( To Be Changed As Per Application ) Flame Height : Maximum 40 ± 2 Mm ( As Per Standard Bs 5867, Astm D6413 & Is 11871 ) Gas Controls System : 1. Electric Solenoid Valve ( Flame Impingement Timer ) 2. Base Valve For Burner Height Adjustment 3. Base Valve For Pilot Light Adjustment Burner Details : 1 ) In Side Diameter : 10 Mm ; 2 ) Height : 76 ± 2 Mm ( Astm D6413 ) 3 ) Type Crease Recovery Tester :Determine The Property Of Textiles To Recover From Crease By Measurement Of The Recovery Angle. Ergonomic Design With Stylish Appearance. 9.63 N ( 980 Gram ) Weight Supplied As Per Iso Standard. 4.90 N ( 500 Gram ) Weight Supplied As Per Aatcc Standard. Calibrated Dial Graduated In Degree For Accurate Recovery Angle. This Instrument Meets The Specifications Of Both Iso & Aatcc Standards. T E C H N I C A L D A T A Creasing Load : 980 Gram ( 9.63 N ) As Per Iso Standard 500 Gram ( 4.90 N ) As Per Aatcc Standard Angle Measurement : On A Sticker Circular Scale Graduated In 1 Degree. Scale Range : 10° - 180°; Least Count : 1° Scale Disc Diameter : 145 Mm Specimen Template Siøe : 40 X 15 Mm Applicable Standard ( S ) : Iso 2313, Aatcc 66, Bs 3086 & Is 4681 Physical Dimensions : Siøe ( Wdh ) : 240 × 140 × 190 Mm Weight : 20 Kg Spray Rating Tester : Determine The Water Repellency Or Surface Wetting Resistance Of Fabrics. Latest Economic Design With Modern Esthetics. Stainless Steel Spray Noøøle For Rust Free, Long Life & Durability. Specimen Holder Is Fixed At 45° To The Specification Of Aatcc Tandard. Appearance Of The Specimen Is Compared Against Photographic Chart. Complete With All Accessories Including 500Ml Beaker. T E C H N I C A L D A T A Test Specimen Siøe : 180 X 180 Mm Square Spray Noøøle Siøe : 1 ) Height : 49 ± 0.38 Mm 2 ) Width : 32.5 ± 0.5 Mm 3 ) Inner Diameter : 4.5 Mm 4 ) Outer Diameter : 8.8 Mm Spray Noøøle : Converse Face With 19 Holes ( Center-1, First Circle-6, Second Circle-12 ) Water Spray Rate : 250 Ml In 25 To 30 Seconds Test Specimen Position : Mounted On A Ring And Placed At An Angle Of 45° Distance Between Center Of Spray : 150 Mm ± 2 Mm Noøøle And Center Of The Specimen Holder Diameter : 150 Mm ± 5 Mm Plastic Funnel Diameter : 150 Mm ± 5 Mm Height Of The Funnel With Noøøle : 200 Mm ±10 Mm Applicable Standard ( S ) : Aatcc 22, Iso 4920, Bs 3702 And Is 390 Physical Dimensions : Siøe ( Wdh ) : 430 X 310 X 480 Mm Weight : 3.5 Kg Advanced Crock Meter-Motorised :Determine The Color Fastness Of Textiles ( Irrespective Of Their Composition Like Wool, Cotton, Linen, Silk, Man-Made Fibers, Etc. ) Against Rubbing Under Wet Or Dry Condition. Motoriøed And Precision-Engineered Mechanism For Smooth And Accurate Operation. Pre-Settable Digital Counter For Strokes 5 To 999 With Auto Stop. Electronically Controlled System To Minimise Operator Variation. Two Types Of Specimen Holders For Rapid Sample Mounting And Repeatability Of Results. Enhanced Testing Provision For Testing Of Yarns, Carpets And Floor Coverings. Designed To Enable Extra Weights And Movement For Nonstandard Tests. T E C H N I C A L D A T A Rubbing Fingers : 1 ) Finger I - Round Φ 16.0 ± 0.1 Mm ; 2 ) Finger Ii - Round Φ 25.0 ± 0.1 Mm 3 ) Finger Iii - Rectangular ( Φ19.0 X 25.4 ) ± 0.1 Mm 4 ) Finger Iv - Round Φ 25.0 ± 0.1 Mm On Φ 32.0 ± 0.1 Mm Finger Movement : 1 ) 104 ± 3 Mm At Position 2 ) 100 ± 2 Mm At Position : 3 ) 76 ± 1 Mm At Position 4 ) 51 ± 1 Mm At Position Download Force : 1 ) 9N ± 5% ( 917.74 Gram ) 2 ) 22N ± 5% ( 2243.38 Gram ) Crocking Cloth Siøe : 1 ) 5 Cm X 5 Cm 2 ) 7.5 Cm X 7.5 Cm Test Specimen Siøe : 25 Cm X 5 Cm For All Fabrics And No Specific Siøe For Multiple Strands Of Yarns Preprogrammable Range : 5 To 999 Strokes Power Supply : Single Phase 220Vac @ 50Hø; Consumption : 50 Watts Applicable Standard ( S ) : Aatcc 8, Aatcc 165, Bs 1006, Bs 4655 & Iso 105 Physical Dimensions : Siøe ( Wdh ) : 300 X 700 X 500 Mm; Weight : 20 Kg Textile Materials To Decide The Commercial Mass And To Study The Effect Of Moisture On Textile Properties. Digital Controlled And Stainless Steel Interior Construction – Compact Model. Removable Tray System With Two Shelves. Easily Accessible Ventilation Port With Adjustable Opening. Equipped With Laboratory Standard Forced Air Circulating Fan For Even Temperature Distribution Inside The Chamber. Suitable For Other Oven- Dry Laboratory Applications. T E C H N I C A L D A T A Usable Volume : 120 Liters ( 450 Mm X 450 Mm X 600 Mm ) Temperature Range : Ambient To 180° C Accuracy : ± 1° C Heater Capacity : 1200 Watts Power Supply : Single Phase 220Vac @ 50 Hø Consumption : 1500 Watts Applicable Standard ( S ) : Perspiration Tester : Determine The Color Fastness Of Textile Against Water And Perspiration ( Applicable To Dyed, Printed Or Otherwise Colored Textile Fibers, Yarns And Fabric Of All Kinds ) . Sturdy High Grade Stainless Steel Construction. Dual Plates, Compensating Springs, Loading Weights Are Made As Per Standard Requirement. Easy, Comfort And Focal Point Placement Of Loading Weights Ensures Even Pressure Distribution Throughout The Sample. T E C H N I C A L D A T A Capacity : 21 Samples Loading Weight “A” ( Aatcc ) : 3.63 Kg ( 8.0 Lb ) Additional Weight “B” ( For Iso ) : 0.56 Kg ( A+B = 12.5 Kpa On Sample ) Weight Of Dual Plate Assembly : 0.91 Kg ( 2.0 Lb ) Siøe Of Acrylic Separator Plate : 60 X 115 X 1.5 Mm Test Specimen Siøe : 1 ) ( 60 X 60 ) ± 20 Mm For Aatcc 2 ) 40 X 100 Mm For Iso & Bs Multifibre Test Fabric Siøe : 1 ) ( 60 X 60 ) ± 20 Mm For Aatcc 2 ) 40 X 100 Sample Conditioning Chamber :Prepare The Test Specimen Under Standard Climatic Conditions For Required Test. Double Walled Construction, With Inner Highygrade Stainless Steel Body. Low Pressure Boiler That Generates Stream For Chamber Humidification. Ambient Condition Such As Temperature 21 / 27 ± 2°C & Humidity 65 ± 5% Can Be Easily Attended. Dynamically Balanced Chamber Circulation With Well Balanced Refrigeration System. Transparent Viewing Window To View The Sample. Light Fitted Inside The Chamber For Viewing The Sample. Caste Wheel At Base For Easy Movement. Three Perforated Trays Supplied With The Equipment To Keep The Samples Properly Inside The Chamber. T E C H N I C A L D A T A Chamber Siøe : 418 X 440 X 825 Mm Capacity : 6.0 Cubic Feet / 150 Liters. Temperature Range : 5 To 60 ± 1° C Humidity : 40 – 90 ± 3 % Standard Temperature For Textile : 21 ± 2°C ( Or ) 27 ± 2°C Standard Humidity For Textile : 65 ± 5 % Power Supply : Single Phase 220Vac @ 50Hø; Consumption : 3000 Watts Applicable Standard ( S ) : Astm D1776 Physical Dimensions : Siøe ( Wdh ) : 630 × 900 × 1500 Mm Weight : 200 Kg Analog Fabric Stiffness Tester For Circular Bend : Determine The Stiffness Of Fabrics In Compliance With Astm Circular Bend Test Method. Automatic Operation With Pneumatic Control Ensures Accurate Operation. Table Top Design; Dial Gauge With Peak-Hold Facility. Dual Test Button System For Ergonomic Comfort. T E C H N I C A L D A T A Capacity : 30 Kgf ( Resolution250 Gf ) Plunger Diameter : 25.4 ( ± 0.1 ) Mm Platform : 102.0 X 102.0 X 6.0 ( ± 0.5 ) Mm Orifice Diameter : 38.1 ( ± 0.05 ) Mm Stroke Length : 57.0 ( ± 0.5 ) Mm Test Specimen Siøe : 204 Mm X 102 Mm Plunger Actuator : Pneumatic Input Pressure : 6 Bar ( 80 Psi / 600 Kpa ) ±10% Set Pressure : 3.24 Bar ( 47Psi / 324 Kpa ) Display : Analogue Dial Gage Applicable Standard ( S ) : Astm D4032 / 1338, Bs 3356 & Is 6490 Physical Dimensions : Siøe ( Wdh ) : 450 X 350 X 700 Mm Weight : 15 Kg Color Matching Cabinet -Metal Body : Visual Assessment Of Colors In Munshell Grey Cabin Under Standard Lighting Conditions. Economic Model Fitted With Rocker Switches And Hour Meter. Light Weight Sheet Metal Construction And Supplied Along With Angled Viewing Stand. Used With Electronic Ballasts For Instant Start & Power Saving. Available Light Source: D65, Tl-84, Inc- A, Uvb And Cwf. T E C H N I C A L D A T A Illuminant ( Source ) : 1 ) D65 ( Artificial Daylight; Correlated Color Temperature 6500K ) 2 ) Uvb ( Ultraviolet Black Light ) 3 ) Tl 84 ( Triphosphor Fluorescent Lamp; Correlated Color Temperature 4000K ) 4 ) Cwf ( Cool White Fluorescent Lamp; Correlated Color Temperature 4150K ) 5 ) Inc-A ( Tungsten Filament Light; Correlated Color Temperature 2800K ) Life Time Of The Bulbs : 2000 Hours Length Of The Bulb : 2 Feet Power Supply : Single Phase 220Vac @ 50Hø; Consumption : 20 Watts Applicable Standard ( S ) : Astm D1729, Iso 3664, Bs 950 & Din 6173 Physical Dimensions : Siøe ( Wdh ) : 670 × 460 × 540 Mm Weight : 20 Kg ( Capacity 50 Kg ) Technical High Lights The Machines Are Used In The Processing Of Linen & Garments With Water As Medium To Wash. These Machines Are Made Out Of Tested Stainless Steel Of Aisi Grade 304 On The Front Cover & Wetted Parts.The Machine Comes With A Water Level Indicator & A Stainless Steel Chemical Hopper. Heating Of The Wash Load Is Via Direct Steam Injection, Or Via Stainless Steel Electric Heating Elements. The Chemical Enter The Wash Cycle In The Inner Basket Via A Stainless Steel Chemical Box Fitted On The Side Of The Machine. Technical Specification: Basket Volume ( Ltrs ) : 565 Basket Dept ( Mm ) : 720 Basket Diameter ( Mm ) : 1000 Door Opening ( Mm ) : 670 Motor ( Kw ) : 2.25 Steam Inlet ( Inch ) : 1 Water Inlet ( Inch ) : 1.5 Drain Outlet ( Mm ) : 75 Heater ( Optional ) ( Kw ) : 18 Dimension ( Wxdxh ) ( Mm ) : 1240X1400x1890 Approx Weight ( Kgs ) : 740 ( Capacity 100 Kg ) Technical High Lights The Machines Are Used In The Processing Of Linen & Garments With Water As Medium To Wash. These Machines Are Made Out Of Tested Stainless Steel Of Aisi Grade 304 On The Front Cover & Wetted Parts.The Machine Comes With A Water Level Indicator & A Stainless Steel Chemical Hopper. Heating Of The Wash Load Is Via Direct Steam Injection, Or Via Stainless Steel Electric Heating Elements.The Chemical Enter The Wash Cycle In The Inner Basket Via A Stainless Steel Chemical Box Fitted On The Side Of The Machine. Technical Specification: Basket Volume ( Ltrs ) : 993 Basket Dept ( Mm ) : 850 Basket Diameter ( Mm ) : 1220 Door Opening ( Mm ) : 670 Motor ( Kw ) : 5.625 Steam Inlet ( Inch ) : 1 Water Inlet ( Inch ) : 2 Drain Outlet ( Mm ) : 75 Heater ( Optional ) ( Kw ) : 27 Dimension ( Wxdxh ) 1700X1750x2230 Approx Weight ( Kgs ) : 1100 Hydro Extractor  ( Capacity 50 Kg ) Technical High Lights High Capacity, Efficient As Its Less Energy Consumption. Auto Controlled Devices, Timer & Balanced Protection Brake. Overload Display Device And Cover Protector Device Ensures Safety Operation & Extends The Life Span Of Hydro Extractor. Additional Load / Unload Features Make The Operation Very Convenient. A Pneumatic Locking System Enhances Operator Safety By Ensuring The Door Cannot Be Opened While The Basket Is Rotating This Machine Is Manufactured Using A Special Sg Grade Single Frame Casting. Technical Specification: Basket Volume ( Ltrs ) : 209 Basket Dept ( Mm ) : 350 Basket Diameter ( Mm ) : 900 Basket Speed ( Rpm ) : 800 Motor ( Hp ) : 7.5 Drain Size ( Mm ) : 76.2 Door Opening ( Mm ) : 670 Dimension ( Wxdxh ) ( Mm ) : 1800X1400x960 Approx Weight ( Kgs ) : 1156-Tumble Driers-  ( Capacity 30 Kg ) Technical High Lights The Special Radiator / Heat Exchanger Design & Efficient Blower System Makes The Drying Time Of This Ramsons Dryer The Best In Its Class. The Stainless Steel Inner Basket Is Programmable On Time For Forward & Reverse Rotations To Prevent Garments From Entangling& A Large Glass Door Is Provided For Ease Of Loading Unloading Linen / Garments. Programmable Micro Processor Control System Comes Standard With This Machine. Emergency Stop Buttons And A Safety Limit Switch Is Pre Installed To Ensure Safety Of The Operator. High Load Capacity Ratings, Self Cleaning Lint Screen & Other Design Features Makes This Dryer A Space & Energy Saving & Guarantees Faster Drying Time. Technical Specification: Basket Volume ( Ltrs ) : 613 Basket Dept ( Mm ) : 830 Basket Diameter ( Mm ) : 970 Door Opening ( Mm ) : 750 Motor ( Hp ) : 2Air Outlet ( Mm ) : 150X200 Heater ( Optional ) Kw ) : 24 Dimension ( Wxdxh ) ( Mm ) : 1050X1320x1870approx Weight ( Kgs ) : 550 Iner Basket Ss 304-Tumble Driers- ( Capacity 60 Kg ) Technical High Lights The Special Radiator / Heat Exchanger Design & Efficient Blower System Makes The Drying Time Of This Ramsons Dryer The Best In Its Class. The Stainless Steel Inner Basket Is Programmable On Time For Forward & Reverse Rotations To Prevent Garments From Entangling& A Large Glass Door Is Provided For Ease Of Stain Removin G Machine With Compres Sor Thread Sucking Machine With Sensor Electri C Steam Generat Ors Veit Ironing Vaccum Ironing Table With Buck With Tube Light Trey Fitting
Contract Date: Mar 18, 2024 Contract Value : 7.86 Crore
Government Departments No of Bidders 4
Maharashtra View Result →
TenderDetail
Loading tenders